SIO Argo Site:
Pump Diagnostics Page   



Serial= 7683 WMO= 1902413

Return

←PreviousNext→

Cycle 118 GMT 10/ 3/2025 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 36 14.96 474 255 0.26 / 656.05 5 21
2 7 2005.36 40 14.60 3311 1934 2.19 / 657.98 21 59
3 13 1925.20 20 14.58 3209 936 3.12 / 658.92 5 63
4 13 1289.28 20 14.65 2294 672 3.80 / 659.59 5 74
5 13 771.84 20 14.76 1545 456 4.25 / 660.05 5 82
6 13 66.96 20 15.00 459 138 4.39 / 660.18 5 77
7 8 0.04 231 14.96 332 1147 5.54 / 661.33 5 136
Average= 6.61
(KJ/cycle)

Cycle 117 GMT 1/ 3/2025 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 36 14.95 474 255 0.26 / 650.43 5 21
2 7 2005.68 40 14.61 3317 1938 2.19 / 652.37 21 58
3 13 1919.08 20 14.58 3190 930 3.12 / 653.30 5 63
4 13 1377.44 20 14.63 2418 708 3.83 / 654.01 5 74
5 13 839.80 20 14.74 1641 484 4.32 / 654.49 5 83
6 13 72.24 20 14.99 469 141 4.46 / 654.63 5 79
7 8 0.08 231 14.95 336 1160 5.62 / 655.79 5 133
Average= 6.62
(KJ/cycle)

Cycle 116 GMT 19/ 2/2025 5:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 36 14.96 470 253 0.25 / 644.60 5 24
2 7 2006.72 40 14.61 3314 1937 2.19 / 646.54 24 59
3 13 1922.52 20 14.58 3187 929 3.12 / 647.47 5 62
4 13 1607.00 20 14.57 2758 804 3.92 / 648.27 5 70
5 13 801.20 20 14.75 1586 468 4.39 / 648.74 5 83
6 13 352.08 20 14.89 913 272 4.66 / 649.01 5 85
7 8 0.08 233 14.95 334 1163 5.83 / 650.18 5 137
Average= 6.63
(KJ/cycle)

Cycle 115 GMT 9/ 2/2025 8:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 36 14.96 473 255 0.25 / 638.92 5 22
2 7 2006.40 40 14.60 3316 1937 2.19 / 640.86 39 58
3 13 1927.12 20 14.58 3195 932 3.12 / 641.79 5 63
4 13 1508.48 20 14.60 2612 763 3.89 / 642.55 5 71
5 13 849.76 20 14.74 1646 485 4.37 / 643.03 5 82
6 13 90.68 20 14.99 498 149 4.52 / 643.18 5 78
7 13 21.56 20 15.00 382 115 4.63 / 643.30 5 76
8 8 0.12 214 14.95 329 1053 5.69 / 644.35 5 137
Average= 6.64
(KJ/cycle)

Cycle 114 GMT 30/ 1/2025 11:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 36 14.96 477 257 0.26 / 633.41 5 22
2 7 2006.84 40 14.61 3308 1933 2.19 / 635.35 22 59
3 13 1911.32 20 14.59 3170 925 3.12 / 636.27 5 64
4 13 1188.32 20 14.68 2153 632 3.75 / 636.90 5 75
5 13 864.24 20 14.73 1671 492 4.24 / 637.40 5 82
6 13 51.24 20 15.00 434 130 4.37 / 637.53 5 76
7 8 0.12 231 14.96 329 1137 5.51 / 638.66 5 136
Average= 6.65
(KJ/cycle)

Cycle 113 GMT 20/ 1/2025 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 36 14.97 472 254 0.25 / 627.74 5 23
2 7 2005.80 40 14.61 3307 1933 2.19 / 629.68 23 59
3 13 1920.96 20 14.59 3192 931 3.12 / 630.61 5 63
4 13 1485.76 20 14.61 2570 751 3.87 / 631.36 5 71
5 13 815.24 20 14.76 1598 472 4.34 / 631.83 5 82
6 13 140.16 20 14.97 579 173 4.51 / 632.00 5 82
7 8 0.00 231 14.96 334 1154 5.67 / 633.16 5 140
Average= 6.66
(KJ/cycle)

Cycle 112 GMT 10/ 1/2025 17: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 36 14.94 461 248 0.25 / 622.07 5 25
2 7 2005.24 40 14.61 3304 1931 2.18 / 624.00 25 60
3 13 1921.00 20 14.60 3188 931 3.11 / 624.93 5 64
4 13 1485.40 20 14.61 2575 752 3.86 / 625.69 5 72
5 13 911.08 20 14.73 1734 511 4.37 / 626.20 5 81
6 13 79.60 20 15.00 479 144 4.52 / 626.34 5 79
7 8 0.12 229 14.96 335 1148 5.66 / 627.49 5 137
Average= 6.68
(KJ/cycle)

Cycle 111 GMT 31/12/2024 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 36 14.95 472 254 0.25 / 616.28 5 26
2 7 2004.36 41 14.60 3307 1980 2.23 / 618.26 26 59
3 13 1911.80 20 14.59 3163 923 3.16 / 619.18 5 63
4 13 1593.40 20 14.59 2718 793 3.95 / 619.98 5 70
5 13 723.64 20 14.79 1469 435 4.38 / 620.41 5 83
6 13 282.76 20 14.92 809 241 4.63 / 620.65 5 86
7 13 30.44 20 15.00 403 121 4.75 / 620.77 5 80
8 8 0.00 210 14.95 335 1052 5.80 / 621.82 5 132
Average= 6.69
(KJ/cycle)

Cycle 110 GMT 21/12/2024 23:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 36 14.95 465 250 0.25 / 610.71 5 25
2 7 2005.96 40 14.61 3306 1932 2.18 / 612.64 25 58
3 13 1922.52 20 14.59 3191 931 3.11 / 613.57 5 62
4 13 1298.04 20 14.66 2302 675 3.79 / 614.25 5 73
5 13 790.64 20 14.76 1562 461 4.25 / 614.71 5 84
6 13 122.40 20 14.98 552 165 4.41 / 614.87 5 80
7 8 0.04 229 14.96 336 1151 5.57 / 616.03 5 133
Average= 6.70
(KJ/cycle)

Cycle 109 GMT 12/12/2024 2: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 36 14.96 491 264 0.26 / 604.90 5 27
2 7 2013.72 41 14.61 3322 1990 2.25 / 606.89 27 59
3 13 1934.20 20 14.59 3190 931 3.19 / 607.82 5 62
4 13 1402.60 20 14.63 2454 718 3.90 / 608.54 5 72
5 13 953.88 20 14.71 1809 532 4.44 / 609.07 5 80
6 13 247.04 20 14.93 748 223 4.66 / 609.30 5 84
7 8 0.04 232 14.96 335 1163 5.82 / 610.46 5 133
Average= 6.71
(KJ/cycle)

Cycle 108 GMT 2/12/2024 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 36 14.96 480 259 0.26 / 599.27 5 28
2 7 2010.72 40 14.61 3317 1938 2.20 / 601.20 28 59
3 13 1927.76 20 14.59 3201 934 3.13 / 602.14 5 64
4 13 1382.08 20 14.64 2426 710 3.84 / 602.85 5 73
5 13 852.12 20 14.74 1655 488 4.33 / 603.34 5 82
6 13 84.84 20 15.00 491 147 4.48 / 603.48 5 78
7 8 0.00 229 14.96 337 1155 5.63 / 604.64 5 137
Average= 6.72
(KJ/cycle)

Cycle 107 GMT 22/11/2024 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 36 14.96 480 259 0.26 / 593.46 5 29
2 7 2012.48 40 14.61 3316 1938 2.20 / 595.39 29 60
3 13 1925.68 20 14.60 3200 934 3.13 / 596.33 5 62
4 13 1622.64 20 14.58 2757 804 3.93 / 597.13 5 70
5 13 944.60 20 14.72 1790 527 4.46 / 597.66 5 81
6 13 158.56 20 14.97 611 183 4.64 / 597.84 5 79
7 8 0.08 232 14.96 336 1166 5.81 / 599.01 5 132
Average= 6.73
(KJ/cycle)

Cycle 106 GMT 12/11/2024 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 36 14.95 478 257 0.26 / 587.73 5 29
2 7 2010.44 40 14.62 3311 1936 2.19 / 589.67 29 58
3 13 1914.68 20 14.60 3189 931 3.12 / 590.60 5 63
4 13 1490.48 20 14.61 2565 749 3.87 / 591.35 5 72
5 13 924.40 20 14.73 1756 517 4.39 / 591.86 5 81
6 13 140.56 20 14.98 579 173 4.56 / 592.04 5 78
7 8 0.12 232 14.97 334 1160 5.72 / 593.20 5 136
Average= 6.74
(KJ/cycle)

Cycle 105 GMT 2/11/2024 14: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 36 14.96 480 259 0.26 / 582.05 5 30
2 7 2004.24 40 14.61 3312 1936 2.19 / 583.99 30 58
3 13 1915.80 20 14.60 3170 926 3.12 / 584.91 5 65
4 13 1393.84 20 14.64 2437 714 3.83 / 585.63 5 73
5 13 840.80 20 14.75 1633 482 4.31 / 586.11 5 82
6 13 266.28 20 14.93 779 233 4.55 / 586.34 5 83
7 8 0.12 227 14.97 333 1132 5.68 / 587.47 5 133
Average= 6.75
(KJ/cycle)

Cycle 104 GMT 23/10/2024 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 36 14.95 482 259 0.26 / 576.42 5 32
2 7 2007.20 40 14.62 3316 1939 2.20 / 578.36 32 58
3 13 1925.64 20 14.60 3208 937 3.14 / 579.30 5 63
4 13 1499.08 20 14.61 2590 757 3.89 / 580.06 5 71
5 13 746.84 20 14.79 1502 444 4.34 / 580.50 5 83
6 13 55.72 20 15.02 436 131 4.47 / 580.63 5 74
7 8 0.04 231 14.97 336 1162 5.63 / 581.79 5 137
Average= 6.77
(KJ/cycle)

Cycle 103 GMT 13/10/2024 20: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 36 14.94 491 264 0.26 / 570.75 5 34
2 7 2006.48 40 14.61 3304 1931 2.19 / 572.69 34 58
3 13 1922.40 20 14.59 3187 930 3.12 / 573.62 5 63
4 13 1314.72 20 14.66 2321 681 3.81 / 574.30 5 73
5 13 897.56 20 14.73 1716 506 4.31 / 574.80 5 83
6 13 217.04 20 14.95 703 210 4.52 / 575.01 5 83
7 8 0.28 227 14.96 339 1151 5.67 / 576.16 5 133
Average= 6.78
(KJ/cycle)

Cycle 102 GMT 3/10/2024 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 36 14.95 493 265 0.27 / 565.14 5 32
2 7 2004.72 40 14.62 3307 1934 2.20 / 567.08 51 58
3 13 1916.20 20 14.60 3170 926 3.12 / 568.00 5 63
4 13 1274.12 20 14.67 2269 666 3.79 / 568.67 5 76
5 13 851.80 20 14.75 1652 487 4.28 / 569.16 5 83
6 13 161.44 20 14.97 611 183 4.46 / 569.34 5 81
7 8 0.04 227 14.96 339 1151 5.61 / 570.49 5 137
Average= 6.79
(KJ/cycle)

Cycle 101 GMT 24/ 9/2024 2: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 36 14.94 496 267 0.27 / 559.42 5 33
2 7 2004.12 40 14.62 3316 1939 2.21 / 561.36 33 59
3 13 1919.16 20 14.60 3203 935 3.14 / 562.30 5 63
4 13 1394.56 20 14.64 2443 715 3.86 / 563.01 5 75
5 13 953.76 20 14.72 1810 533 4.39 / 563.54 5 81
6 13 177.08 20 14.96 645 193 4.58 / 563.74 5 81
7 8 0.00 227 14.97 336 1142 5.72 / 564.88 5 129
Average= 6.81
(KJ/cycle)

Cycle 100 GMT 14/ 9/2024 4:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 36 14.96 487 262 0.26 / 553.71 5 32
2 7 2006.76 40 14.62 3316 1939 2.20 / 555.65 32 60
3 13 1924.16 20 14.61 3193 933 3.13 / 556.58 5 64
4 13 1380.96 20 14.64 2430 712 3.85 / 557.30 5 72
5 13 850.88 20 14.75 1651 487 4.33 / 557.78 5 83
6 13 185.16 20 14.96 659 197 4.53 / 557.98 5 83
7 8 0.04 229 14.96 343 1175 5.71 / 559.15 5 135
Average= 6.82
(KJ/cycle)

Cycle 99 GMT 4/ 9/2024 7:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 36 14.95 492 265 0.26 / 548.17 5 31
2 7 2012.88 40 14.62 3315 1939 2.20 / 550.11 31 59
3 13 1916.04 20 14.61 3194 933 3.14 / 551.04 5 63
4 13 1301.64 20 14.67 2306 677 3.81 / 551.72 5 74
5 13 775.52 20 14.78 1542 456 4.27 / 552.17 5 83
6 13 59.80 20 15.01 453 136 4.41 / 552.31 5 76
7 8 0.04 227 14.97 336 1142 5.55 / 553.45 5 130
Average= 6.83
(KJ/cycle)

Cycle 98 GMT 25/ 8/2024 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 36 14.96 482 260 0.26 / 542.48 5 31
2 7 2008.00 40 14.62 3315 1939 2.20 / 544.42 31 58
3 13 1927.80 20 14.60 3199 934 3.13 / 545.35 5 63
4 13 1395.40 20 14.64 2445 716 3.85 / 546.07 5 74
5 13 741.44 20 14.79 1489 440 4.29 / 546.51 5 83
6 13 296.60 20 14.91 833 248 4.54 / 546.76 5 86
7 8 0.12 227 14.96 337 1144 5.68 / 547.90 5 130
Average= 6.85
(KJ/cycle)

Cycle 97 GMT 15/ 8/2024 13:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 36 14.96 497 268 0.27 / 536.83 5 32
2 7 2005.72 41 14.62 3321 1991 2.26 / 538.82 32 59
3 13 1917.08 20 14.60 3174 927 3.19 / 539.75 5 63
4 13 1361.36 20 14.65 2399 703 3.89 / 540.45 5 74
5 13 826.88 20 14.76 1621 479 4.37 / 540.93 5 81
6 13 78.40 20 15.01 482 145 4.51 / 541.07 5 76
7 8 0.04 229 14.97 335 1148 5.66 / 542.22 5 134
Average= 6.86
(KJ/cycle)

Cycle 96 GMT 5/ 8/2024 16:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 36 14.96 477 257 0.26 / 531.13 5 27
2 7 2003.52 41 14.62 3310 1984 2.24 / 533.12 27 59
3 13 1910.16 20 14.60 3189 931 3.17 / 534.05 5 64
4 13 1373.28 20 14.65 2409 706 3.88 / 534.75 5 74
5 13 720.60 20 14.80 1465 434 4.31 / 535.19 5 84
6 13 274.96 20 14.93 791 236 4.55 / 535.42 5 82
7 8 0.08 227 14.97 335 1138 5.69 / 536.56 5 134
Average= 6.88
(KJ/cycle)

Cycle 95 GMT 26/ 7/2024 19:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 36 14.97 479 258 0.26 / 525.58 5 27
2 7 2004.16 40 14.62 3312 1937 2.20 / 527.52 27 59
3 13 1915.32 20 14.61 3186 931 3.13 / 528.45 5 62
4 13 1273.68 20 14.68 2265 665 3.79 / 529.11 5 75
5 13 850.96 20 14.75 1653 488 4.28 / 529.60 5 82
6 13 81.56 20 15.01 482 145 4.42 / 529.74 5 75
7 8 0.20 227 14.97 333 1132 5.55 / 530.88 5 129
Average= 6.89
(KJ/cycle)

Cycle 94 GMT 16/ 7/2024 22:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 36 14.96 486 262 0.26 / 519.97 5 26
2 7 2010.16 40 14.62 3318 1940 2.20 / 521.91 26 60
3 13 1932.52 20 14.60 3215 939 3.14 / 522.85 5 61
4 13 1395.16 20 14.64 2449 717 3.86 / 523.57 5 73
5 13 856.08 20 14.75 1662 490 4.35 / 524.06 5 82
6 13 47.64 20 15.02 422 127 4.48 / 524.19 5 74
7 8 0.16 227 14.98 333 1132 5.61 / 525.32 5 134
Average= 6.91
(KJ/cycle)

Cycle 93 GMT 7/ 7/2024 1:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 36 14.96 487 262 0.26 / 514.30 5 25
2 7 2007.56 40 14.63 3310 1937 2.20 / 516.24 25 60
3 13 1922.92 20 14.61 3199 935 3.13 / 517.17 5 63
4 13 1483.52 20 14.63 2566 751 3.88 / 517.92 5 69
5 13 815.52 20 14.77 1604 474 4.36 / 518.39 5 80
6 13 152.80 20 14.98 600 180 4.54 / 518.57 5 78
7 8 0.16 229 14.97 332 1138 5.68 / 519.71 5 132
Average= 6.93
(KJ/cycle)

Cycle 92 GMT 27/ 6/2024 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 36 14.96 480 259 0.26 / 508.65 5 26
2 7 2005.16 41 14.62 3312 1985 2.24 / 510.64 26 61
3 13 1912.60 20 14.61 3194 933 3.18 / 511.57 5 63
4 13 1275.12 20 14.67 2268 665 3.84 / 512.24 5 75
5 13 841.92 20 14.75 1645 485 4.33 / 512.72 5 82
6 13 167.04 20 14.97 624 187 4.51 / 512.91 5 80
7 8 0.04 227 14.97 332 1128 5.64 / 514.04 5 133
Average= 6.95
(KJ/cycle)

Cycle 91 GMT 17/ 6/2024 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 36 14.96 477 257 0.26 / 503.02 5 25
2 7 2005.40 40 14.63 3303 1933 2.19 / 504.96 25 58
3 13 1916.96 20 14.61 3193 933 3.12 / 505.89 5 61
4 13 1385.68 20 14.65 2430 712 3.83 / 506.60 5 74
5 13 766.40 20 14.78 1524 450 4.29 / 507.05 5 82
6 13 217.36 20 14.95 704 210 4.50 / 507.26 5 82
7 8 0.04 229 14.97 330 1131 5.63 / 508.39 5 134
Average= 6.96
(KJ/cycle)

Cycle 90 GMT 7/ 6/2024 10:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 36 14.96 479 258 0.26 / 497.24 5 21
2 7 2013.56 40 14.62 3320 1942 2.20 / 499.19 21 58
3 13 1918.92 20 14.60 3191 932 3.13 / 500.12 5 63
4 13 1484.04 20 14.62 2570 751 3.88 / 500.87 5 71
5 13 910.68 20 14.73 1750 516 4.40 / 501.38 5 83
6 13 233.84 20 14.94 726 217 4.62 / 501.60 5 81
7 8 0.12 229 14.96 340 1165 5.78 / 502.77 5 138
Average= 6.98
(KJ/cycle)

Cycle 89 GMT 28/ 5/2024 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 36 14.97 458 247 0.25 / 491.59 5 21
2 7 2006.36 40 14.62 3318 1940 2.19 / 493.53 21 59
3 13 1920.80 20 14.60 3188 931 3.12 / 494.46 5 63
4 13 1370.80 20 14.65 2414 707 3.83 / 495.17 5 73
5 13 835.32 20 14.76 1630 481 4.31 / 495.65 5 82
6 13 160.24 20 14.97 605 181 4.49 / 495.83 5 79
7 8 0.16 231 14.97 334 1155 5.64 / 496.99 5 134
Average= 7.00
(KJ/cycle)

Cycle 88 GMT 18/ 5/2024 16:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 36 14.97 457 246 0.25 / 486.02 5 22
2 7 2004.32 40 14.62 3312 1937 2.18 / 487.96 22 59
3 13 1912.16 20 14.60 3177 928 3.11 / 488.89 5 65
4 13 1376.28 20 14.65 2413 707 3.82 / 489.59 5 71
5 13 833.12 20 14.76 1620 478 4.30 / 490.07 5 81
6 13 50.40 20 15.02 425 128 4.42 / 490.20 5 72
7 8 0.08 233 14.98 328 1145 5.57 / 491.34 5 136
Average= 7.02
(KJ/cycle)

Cycle 87 GMT 8/ 5/2024 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 36 14.96 476 256 0.26 / 480.46 5 21
2 7 2009.40 40 14.63 3301 1932 2.19 / 482.40 21 59
3 13 1914.16 20 14.61 3182 930 3.12 / 483.32 5 64
4 13 1286.48 20 14.67 2279 669 3.79 / 483.99 5 73
5 13 855.28 20 14.75 1657 489 4.28 / 484.48 5 82
6 13 99.64 20 15.00 512 154 4.43 / 484.64 5 77
7 8 0.24 232 14.97 328 1139 5.57 / 485.78 5 135
Average= 7.04
(KJ/cycle)

Cycle 86 GMT 28/ 4/2024 22:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 36 14.96 479 258 0.26 / 474.85 5 20
2 7 2003.28 40 14.63 3300 1931 2.19 / 476.78 20 60
3 13 1910.24 20 14.61 3165 925 3.11 / 477.70 5 64
4 13 1292.04 20 14.67 2283 670 3.78 / 478.37 5 74
5 13 862.64 20 14.75 1670 493 4.28 / 478.87 5 83
6 13 174.60 20 14.97 623 187 4.46 / 479.05 5 79
7 8 0.12 233 14.97 331 1155 5.62 / 480.21 5 135
Average= 7.06
(KJ/cycle)

Cycle 85 GMT 19/ 4/2024 1:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 36 14.97 474 255 0.26 / 469.20 5 21
2 7 2007.24 40 14.63 3317 1941 2.20 / 471.15 21 62
3 13 1920.00 20 14.61 3186 931 3.13 / 472.08 5 64
4 13 1279.12 20 14.67 2271 666 3.79 / 472.74 5 73
5 13 745.80 20 14.78 1498 443 4.24 / 473.19 5 83
6 13 291.44 20 14.92 813 243 4.48 / 473.43 5 84
7 8 0.08 233 14.96 333 1161 5.64 / 474.59 5 140
Average= 7.08
(KJ/cycle)

Cycle 84 GMT 9/ 4/2024 4: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 36 14.96 460 248 0.25 / 463.59 5 20
2 7 2005.08 40 14.63 3302 1932 2.18 / 465.52 20 60
3 13 1914.88 20 14.61 3185 931 3.11 / 466.45 5 64
4 13 1488.52 20 14.62 2580 754 3.87 / 467.21 5 71
5 13 738.16 20 14.79 1487 440 4.30 / 467.65 5 82
6 13 97.12 20 15.00 508 152 4.46 / 467.80 5 75
7 13 21.96 20 15.01 381 114 4.57 / 467.92 5 73
8 8 0.12 210 14.97 329 1034 5.61 / 468.95 5 130
Average= 7.11
(KJ/cycle)

Cycle 83 GMT 30/ 3/2024 7: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 36 14.96 453 244 0.24 / 457.95 5 19
2 7 2010.48 40 14.63 3314 1939 2.18 / 459.89 19 60
3 13 1921.36 20 14.61 3194 933 3.12 / 460.83 5 64
4 13 1379.96 20 14.65 2424 710 3.83 / 461.54 5 72
5 13 832.60 20 14.75 1630 481 4.31 / 462.02 5 82
6 13 163.76 20 14.97 616 184 4.49 / 462.20 5 80
7 8 0.32 231 14.96 330 1140 5.63 / 463.34 5 131
Average= 7.13
(KJ/cycle)

Cycle 82 GMT 20/ 3/2024 10: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 36 14.96 476 256 0.26 / 452.40 5 20
2 7 2013.20 40 14.63 3318 1942 2.20 / 454.34 20 60
3 13 1920.08 20 14.61 3181 929 3.13 / 455.27 5 63
4 13 1397.40 20 14.64 2445 716 3.84 / 455.98 5 71
5 13 744.80 20 14.78 1495 442 4.29 / 456.42 5 83
6 13 99.52 20 15.00 507 152 4.44 / 456.58 5 77
7 8 0.08 231 14.97 328 1134 5.57 / 457.71 5 129
Average= 7.15
(KJ/cycle)

Cycle 81 GMT 10/ 3/2024 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 36 14.96 476 256 0.26 / 446.78 5 20
2 7 2005.72 40 14.63 3312 1938 2.19 / 448.72 20 61
3 13 1915.36 20 14.61 3177 928 3.12 / 449.65 5 64
4 13 1281.88 20 14.67 2269 666 3.79 / 450.31 5 73
5 13 837.64 20 14.75 1630 481 4.27 / 450.79 5 82
6 13 157.68 20 14.97 598 179 4.45 / 450.97 5 79
7 13 29.60 20 15.01 390 117 4.57 / 451.09 5 75
8 8 0.08 212 14.96 331 1050 5.62 / 452.14 5 132
Average= 7.18
(KJ/cycle)

Cycle 80 GMT 29/ 2/2024 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 36 14.96 478 257 0.26 / 441.16 5 20
2 7 2006.76 40 14.63 3311 1938 2.20 / 443.10 20 61
3 13 1918.20 20 14.61 3188 932 3.13 / 444.03 5 65
4 13 1370.20 20 14.65 2400 703 3.83 / 444.73 5 74
5 13 822.04 20 14.76 1612 476 4.31 / 445.21 5 82
6 13 133.88 20 14.98 570 171 4.48 / 445.38 5 80
7 8 0.04 231 14.96 331 1144 5.62 / 446.52 5 135
Average= 7.20
(KJ/cycle)

Cycle 79 GMT 19/ 2/2024 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 36 14.95 490 264 0.26 / 435.51 5 18
2 7 2005.84 40 14.63 3307 1935 2.20 / 437.45 18 60
3 13 1911.12 20 14.61 3177 928 3.13 / 438.38 5 63
4 13 1362.20 20 14.65 2392 701 3.83 / 439.08 5 74
5 13 914.56 20 14.73 1740 513 4.34 / 439.59 5 78
6 13 122.80 20 14.98 551 165 4.51 / 439.76 5 78
7 8 0.12 233 14.96 329 1147 5.65 / 440.90 5 139
Average= 7.23
(KJ/cycle)

Cycle 78 GMT 9/ 2/2024 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 36 14.97 466 251 0.25 / 429.83 5 20
2 7 2005.52 40 14.63 3310 1937 2.19 / 431.76 20 61
3 13 1916.68 20 14.61 3186 931 3.12 / 432.69 5 64
4 13 1481.08 20 14.62 2567 751 3.87 / 433.44 5 72
5 13 804.28 20 14.76 1587 468 4.34 / 433.91 5 83
6 13 132.48 20 14.97 567 170 4.51 / 434.08 5 78
7 8 0.16 231 14.96 338 1168 5.68 / 435.25 5 130
Average= 7.25
(KJ/cycle)

Cycle 77 GMT 31/ 1/2024 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 36 14.95 479 258 0.26 / 424.16 5 20
2 7 2014.12 40 14.63 3316 1941 2.20 / 426.10 20 59
3 13 1915.40 20 14.61 3175 928 3.13 / 427.03 5 64
4 13 1364.16 20 14.65 2403 704 3.83 / 427.74 5 73
5 13 906.08 20 14.73 1741 513 4.34 / 428.25 5 81
6 13 118.64 20 14.98 541 162 4.51 / 428.41 5 77
7 8 0.12 233 14.96 334 1164 5.67 / 429.58 5 132
Average= 7.28
(KJ/cycle)

Cycle 76 GMT 21/ 1/2024 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 36 14.96 468 252 0.25 / 418.31 5 18
2 7 2005.00 40 14.64 3316 1942 2.19 / 420.26 18 62
3 13 1920.36 20 14.62 3192 933 3.13 / 421.19 5 63
4 13 1496.16 20 14.62 2588 757 3.88 / 421.95 5 71
5 13 841.52 20 14.75 1647 486 4.37 / 422.43 5 82
6 13 390.16 20 14.88 973 290 4.66 / 422.72 5 86
7 8 0.16 231 14.95 343 1185 5.84 / 423.91 5 130
Average= 7.31
(KJ/cycle)

Cycle 75 GMT 11/ 1/2024 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 36 14.94 486 261 0.26 / 412.55 5 24
2 7 2007.68 40 14.64 3319 1944 2.20 / 414.50 24 60
3 13 1923.36 20 14.62 3201 936 3.14 / 415.43 5 63
4 13 1480.96 20 14.63 2567 751 3.89 / 416.18 5 71
5 13 1028.72 20 14.70 1914 563 4.45 / 416.75 5 78
6 13 71.72 20 15.01 465 140 4.59 / 416.89 5 70
7 13 15.12 20 15.02 370 111 4.71 / 417.00 5 71
8 8 0.04 212 14.96 336 1066 5.77 / 418.06 5 136
Average= 7.33
(KJ/cycle)

Cycle 74 GMT 1/ 1/2024 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 36 14.95 462 249 0.25 / 406.76 5 22
2 7 2006.44 41 14.64 3317 1991 2.24 / 408.76 22 61
3 13 1922.48 20 14.62 3191 933 3.17 / 409.69 5 63
4 13 1386.40 20 14.65 2437 714 3.89 / 410.40 5 72
5 13 858.68 20 14.74 1662 490 4.38 / 410.89 5 81
6 13 281.44 20 14.92 807 241 4.62 / 411.13 5 85
7 8 -0.08 229 14.95 338 1157 5.77 / 412.29 5 131
Average= 7.36
(KJ/cycle)

Cycle 73 GMT 22/12/2023 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 36 14.96 480 259 0.26 / 400.85 5 20
2 7 2012.84 41 14.64 3327 1997 2.26 / 402.85 20 61
3 13 1936.40 20 14.61 3233 945 3.20 / 403.79 5 62
4 13 1423.16 20 14.64 2488 728 3.93 / 404.52 5 71
5 13 1069.84 20 14.68 1977 580 4.51 / 405.10 5 80
6 13 255.72 20 14.93 766 229 4.74 / 405.33 5 83
7 8 0.04 233 14.95 340 1184 5.92 / 406.52 5 136
Average= 7.39
(KJ/cycle)

Cycle 72 GMT 12/12/2023 15:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 36 14.94 486 261 0.26 / 395.32 5 23
2 7 2004.40 40 14.66 3310 1941 2.20 / 397.26 23 61
3 13 1913.80 20 14.64 3174 929 3.13 / 398.19 5 63
4 13 1293.28 20 14.68 2292 673 3.80 / 398.87 5 74
5 13 749.36 20 14.78 1512 447 4.25 / 399.31 5 85
6 13 52.40 20 15.01 437 131 4.38 / 399.45 5 75
7 8 0.08 229 14.97 335 1148 5.53 / 400.59 5 130
Average= 7.42
(KJ/cycle)

Cycle 71 GMT 2/12/2023 18:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 36 14.95 473 255 0.25 / 389.57 5 26
2 7 2003.76 40 14.65 3313 1941 2.20 / 391.52 26 61
3 13 1914.40 20 14.63 3187 933 3.13 / 392.45 5 62
4 13 1306.52 20 14.67 2318 680 3.81 / 393.13 5 74
5 13 961.00 20 14.72 1810 533 4.34 / 393.66 5 82
6 13 265.00 20 14.92 783 234 4.58 / 393.90 5 87
7 8 0.08 229 14.95 341 1167 5.74 / 395.06 5 136
Average= 7.45
(KJ/cycle)

Cycle 70 GMT 22/11/2023 21:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 36 14.95 499 269 0.27 / 383.50 5 28
2 7 2007.84 40 14.65 3318 1944 2.21 / 385.45 28 61
3 13 1929.64 20 14.63 3211 940 3.15 / 386.39 5 63
4 13 1834.64 20 14.57 3065 893 4.05 / 387.28 5 65
5 13 904.40 20 14.75 1731 511 4.56 / 387.79 5 82
6 13 583.44 20 14.82 1261 374 4.93 / 388.17 5 88
7 8 0.16 229 14.96 337 1155 6.08 / 389.32 5 129
Average= 7.49
(KJ/cycle)

Cycle 69 GMT 13/11/2023 0:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 36 14.95 486 262 0.26 / 377.86 5 29
2 7 2011.12 40 14.65 3325 1948 2.21 / 379.81 29 61
3 13 1928.40 20 14.64 3209 940 3.15 / 380.75 5 63
4 13 1299.20 20 14.68 2309 678 3.83 / 381.42 5 75
5 13 861.68 20 14.75 1662 490 4.32 / 381.91 5 79
6 13 106.00 20 14.99 523 157 4.47 / 382.07 5 77
7 8 0.16 229 14.96 340 1165 5.64 / 383.24 5 129
Average= 7.51
(KJ/cycle)

Cycle 68 GMT 3/11/2023 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 36 14.96 488 263 0.26 / 372.19 5 31
2 7 2021.12 40 14.65 3345 1960 2.22 / 374.15 31 59
3 13 1947.36 20 14.63 3231 945 3.17 / 375.10 5 63
4 13 1408.72 20 14.65 2464 722 3.89 / 375.82 5 73
5 13 853.20 20 14.76 1656 489 4.38 / 376.31 5 82
6 13 39.28 20 15.02 410 123 4.50 / 376.43 5 73
7 8 0.04 229 14.97 339 1162 5.66 / 377.60 5 133
Average= 7.55
(KJ/cycle)

Cycle 67 GMT 24/10/2023 6:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 36 14.97 485 261 0.26 / 366.63 5 31
2 7 2004.72 40 14.65 3321 1946 2.21 / 368.57 31 61
3 13 1918.20 20 14.64 3198 936 3.14 / 369.51 5 66
4 13 1296.92 20 14.68 2306 677 3.82 / 370.19 5 73
5 13 754.36 20 14.79 1510 447 4.27 / 370.63 5 83
6 13 94.80 20 15.00 506 152 4.42 / 370.79 5 75
7 8 0.00 229 14.97 334 1145 5.56 / 371.93 5 129
Average= 7.59
(KJ/cycle)

Cycle 66 GMT 14/10/2023 9:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 36 14.97 492 265 0.27 / 361.01 5 32
2 7 2005.44 40 14.66 3306 1939 2.20 / 362.94 32 60
3 13 1918.00 20 14.65 3178 931 3.13 / 363.88 5 63
4 13 1371.36 20 14.67 2415 709 3.84 / 364.58 5 73
5 13 843.04 20 14.77 1644 486 4.33 / 365.07 5 83
6 13 84.12 20 15.02 484 145 4.47 / 365.21 5 74
7 8 0.08 229 14.98 336 1153 5.63 / 366.37 5 129
Average= 7.63
(KJ/cycle)

Cycle 65 GMT 4/10/2023 12:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 36 14.96 495 267 0.27 / 355.26 5 31
2 7 2006.08 40 14.67 3309 1942 2.21 / 357.20 31 60
3 13 1914.72 20 14.65 3180 932 3.14 / 358.13 5 63
4 13 1481.32 20 14.66 2564 752 3.89 / 358.89 5 72
5 13 835.64 20 14.78 1633 483 4.37 / 359.37 5 82
6 13 181.52 20 14.98 644 193 4.57 / 359.56 5 81
7 8 0.08 232 14.98 339 1178 5.75 / 360.74 5 138
Average= 7.68
(KJ/cycle)

Cycle 64 GMT 24/ 9/2023 15:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 36 14.97 493 266 0.27 / 349.52 5 32
2 7 2005.76 41 14.66 3317 1994 2.26 / 351.52 32 61
3 13 1917.24 20 14.65 3186 933 3.19 / 352.45 5 63
4 13 1370.64 20 14.68 2409 707 3.90 / 353.16 5 73
5 13 717.64 20 14.82 1461 433 4.33 / 353.59 5 83
6 13 385.40 20 14.90 964 287 4.62 / 353.88 5 88
7 8 0.12 218 14.97 342 1116 5.74 / 354.99 5 131
Average= 7.72
(KJ/cycle)

Cycle 63 GMT 14/ 9/2023 18:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 36 14.98 475 256 0.26 / 343.73 5 31
2 7 2012.12 40 14.67 3322 1949 2.21 / 345.68 31 59
3 13 1920.24 20 14.65 3202 938 3.14 / 346.62 5 62
4 13 1493.00 20 14.66 2582 757 3.90 / 347.38 5 72
5 13 927.64 20 14.75 1771 522 4.42 / 347.90 5 82
6 13 141.40 20 15.00 580 174 4.60 / 348.07 5 80
7 8 0.08 232 14.99 341 1186 5.78 / 349.26 5 130
Average= 7.76
(KJ/cycle)

Cycle 62 GMT 4/ 9/2023 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 36 14.98 485 262 0.26 / 338.07 5 29
2 7 2007.08 40 14.67 3314 1945 2.21 / 340.01 29 60
3 13 1810.20 20 14.67 3031 889 3.10 / 340.90 5 64
4 13 1603.00 20 14.64 2737 801 3.90 / 341.70 5 68
5 13 719.04 20 14.83 1463 434 4.33 / 342.14 5 84
6 13 178.92 20 15.00 638 191 4.52 / 342.33 5 80
7 8 0.20 227 15.00 337 1147 5.67 / 343.47 5 135
Average= 7.81
(KJ/cycle)

Cycle 61 GMT 26/ 8/2023 0: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 36 14.99 465 251 0.25 / 332.33 5 27
2 7 2007.16 41 14.67 3306 1988 2.24 / 334.32 27 60
3 13 1921.64 20 14.66 3179 932 3.17 / 335.25 5 64
4 13 1378.36 20 14.70 2411 709 3.88 / 335.96 5 73
5 13 841.32 20 14.79 1639 485 4.37 / 336.45 5 82
6 13 162.80 20 15.00 611 183 4.55 / 336.63 5 80
7 8 0.16 231 14.99 339 1174 5.72 / 337.81 5 136
Average= 7.86
(KJ/cycle)

Cycle 60 GMT 16/ 8/2023 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 36 14.99 478 258 0.26 / 326.60 5 27
2 7 2005.36 40 14.68 3308 1942 2.20 / 328.54 27 60
3 13 1916.96 20 14.66 3190 935 3.14 / 329.48 5 65
4 13 1384.20 20 14.69 2434 715 3.85 / 330.20 5 73
5 13 944.12 20 14.76 1792 529 4.38 / 330.72 5 81
6 13 146.72 20 15.02 590 177 4.56 / 330.90 5 79
7 8 0.00 231 15.00 341 1182 5.74 / 332.08 5 132
Average= 7.91
(KJ/cycle)

Cycle 59 GMT 6/ 8/2023 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 36 15.00 490 265 0.26 / 320.99 5 28
2 7 2015.04 40 14.67 3329 1953 2.22 / 322.95 28 62
3 13 1928.92 20 14.65 3206 939 3.16 / 323.89 5 64
4 13 1398.12 20 14.69 2452 720 3.88 / 324.61 5 73
5 13 747.60 20 14.83 1505 446 4.32 / 325.05 5 85
6 13 94.56 20 15.04 502 151 4.48 / 325.20 5 76
7 8 0.08 229 15.01 332 1141 5.62 / 326.34 5 129
Average= 7.96
(KJ/cycle)

Cycle 58 GMT 27/ 7/2023 9: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 36 15.00 506 273 0.27 / 315.20 5 26
2 7 2006.44 41 14.68 3319 1998 2.27 / 317.20 26 62
3 13 1918.80 20 14.66 3187 934 3.21 / 318.13 5 64
4 13 1486.28 20 14.68 2580 757 3.96 / 318.89 5 73
5 13 816.24 20 14.81 1607 476 4.44 / 319.37 5 83
6 13 152.20 20 15.02 601 181 4.62 / 319.55 5 81
7 8 0.08 229 15.01 343 1179 5.80 / 320.73 5 132
Average= 8.02
(KJ/cycle)

Cycle 57 GMT 17/ 7/2023 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 35 15.00 477 250 0.25 / 309.57 5 26
2 7 2006.84 40 14.68 3316 1947 2.20 / 311.52 26 60
3 13 1919.60 20 14.66 3193 936 3.13 / 312.46 5 64
4 13 1384.44 20 14.70 2430 714 3.85 / 313.17 5 74
5 13 736.36 20 14.84 1494 443 4.29 / 313.61 5 85
6 13 90.16 20 15.05 498 150 4.44 / 313.76 5 77
7 8 0.08 229 15.02 339 1166 5.61 / 314.93 5 135
Average= 8.08
(KJ/cycle)

Cycle 56 GMT 7/ 7/2023 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 35 15.01 471 247 0.25 / 304.00 5 26
2 7 2006.84 40 14.68 3314 1946 2.19 / 305.94 26 62
3 13 1922.72 20 14.67 3200 939 3.13 / 306.88 5 64
4 13 1283.44 20 14.74 2282 673 3.81 / 307.55 5 76
5 13 745.28 20 14.84 1504 446 4.25 / 308.00 5 85
6 13 93.48 20 15.05 502 151 4.40 / 308.15 5 77
7 8 0.12 232 15.02 336 1171 5.57 / 309.32 5 136
Average= 8.14
(KJ/cycle)

Cycle 55 GMT 27/ 6/2023 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 35 15.01 492 258 0.26 / 298.34 5 25
2 7 2005.48 40 14.69 3312 1946 2.20 / 300.29 25 61
3 13 1917.76 20 14.67 3195 937 3.14 / 301.22 5 64
4 13 1279.92 20 14.74 2283 673 3.82 / 301.90 5 75
5 13 857.76 20 14.81 1666 493 4.31 / 302.39 5 83
6 13 189.96 20 15.02 662 199 4.51 / 302.59 5 81
7 8 0.04 233 15.02 331 1158 5.67 / 303.75 5 140
Average= 8.21
(KJ/cycle)

Cycle 54 GMT 17/ 6/2023 20:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 35 15.01 468 246 0.25 / 292.71 5 25
2 7 2003.52 41 14.68 3303 1988 2.23 / 294.70 25 61
3 13 1909.92 20 14.67 3178 932 3.17 / 295.63 5 65
4 13 1276.84 20 14.74 2275 671 3.84 / 296.30 5 76
5 13 747.44 20 14.85 1505 447 4.28 / 296.75 5 85
6 13 98.60 20 15.06 511 154 4.44 / 296.90 5 77
7 8 0.08 231 15.03 340 1180 5.62 / 298.08 5 137
Average= 8.28
(KJ/cycle)

Cycle 53 GMT 7/ 6/2023 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 35 15.03 484 255 0.25 / 286.79 5 23
2 7 2004.92 40 14.69 3311 1946 2.20 / 288.73 23 60
3 13 1921.24 20 14.67 3197 938 3.14 / 289.67 5 63
4 13 1611.88 20 14.66 2752 807 3.95 / 290.48 5 70
5 13 1119.68 20 14.74 2051 605 4.55 / 291.08 5 78
6 13 190.68 20 15.03 659 198 4.75 / 291.28 5 82
7 8 0.16 231 15.03 341 1184 5.93 / 292.46 5 134
Average= 8.36
(KJ/cycle)

Cycle 52 GMT 29/ 5/2023 2:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 35 15.03 479 252 0.25 / 281.14 5 22
2 7 2005.48 41 14.68 3309 1992 2.24 / 283.13 22 61
3 13 1917.44 20 14.67 3183 934 3.18 / 284.07 5 64
4 13 1380.92 20 14.72 2422 713 3.89 / 284.78 5 73
5 13 735.44 20 14.86 1489 443 4.33 / 285.22 5 84
6 13 96.24 20 15.07 509 153 4.49 / 285.38 5 77
7 8 0.04 229 15.04 336 1157 5.64 / 286.53 5 129
Average= 8.43
(KJ/cycle)

Cycle 51 GMT 19/ 5/2023 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 35 15.04 485 255 0.26 / 275.46 5 22
2 7 2004.24 40 14.70 3312 1947 2.20 / 277.41 52 62
3 13 1918.52 20 14.67 3195 937 3.14 / 278.34 5 64
4 13 1292.60 20 14.75 2293 676 3.82 / 279.02 5 75
5 13 853.40 20 14.83 1656 491 4.31 / 279.51 5 84
6 13 167.36 20 15.04 631 190 4.50 / 279.70 5 81
7 8 0.16 232 15.03 341 1189 5.69 / 280.89 5 130
Average= 8.51
(KJ/cycle)

Cycle 50 GMT 9/ 5/2023 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 35 15.04 478 252 0.25 / 269.85 5 20
2 7 2005.60 40 14.70 3314 1949 2.20 / 271.80 20 62
3 13 1915.44 20 14.68 3198 939 3.14 / 272.74 5 66
4 13 1385.48 20 14.73 2429 716 3.85 / 273.45 5 74
5 13 728.76 20 14.87 1478 440 4.29 / 273.89 5 85
6 13 52.64 20 15.09 435 131 4.43 / 274.02 5 73
7 8 0.00 233 15.05 336 1178 5.60 / 275.20 5 134
Average= 8.60
(KJ/cycle)

Cycle 49 GMT 29/ 4/2023 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 35 15.04 465 245 0.24 / 264.10 5 20
2 7 2003.88 40 14.70 3319 1952 2.20 / 266.05 20 61
3 13 1916.40 20 14.68 3179 933 3.13 / 266.98 5 63
4 13 1393.16 20 14.73 2443 720 3.85 / 267.70 5 73
5 13 1051.56 20 14.78 1950 576 4.43 / 268.28 5 80
6 13 138.92 20 15.06 577 174 4.60 / 268.45 5 80
7 8 0.36 229 15.05 333 1148 5.75 / 269.60 5 129
Average= 8.70
(KJ/cycle)

Cycle 48 GMT 19/ 4/2023 14:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 35 15.05 489 258 0.26 / 258.51 5 21
2 7 2008.08 40 14.70 3310 1946 2.20 / 260.46 21 59
3 13 1926.40 20 14.68 3203 940 3.14 / 261.40 5 64
4 13 1282.04 20 14.76 2277 672 3.82 / 262.07 5 74
5 13 747.60 20 14.87 1505 448 4.26 / 262.52 5 85
6 13 101.40 20 15.08 516 156 4.42 / 262.68 5 76
7 8 0.12 231 15.05 338 1175 5.59 / 263.85 5 131
Average= 8.80
(KJ/cycle)

Cycle 47 GMT 9/ 4/2023 17:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 35 15.04 479 252 0.25 / 252.84 5 22
2 7 2003.00 40 14.70 3310 1946 2.20 / 254.79 22 61
3 13 1906.52 20 14.69 3174 933 3.13 / 255.72 5 64
4 13 1470.16 20 14.72 2542 748 3.88 / 256.47 5 71
5 13 780.00 20 14.87 1556 463 4.34 / 256.93 5 86
6 13 100.00 20 15.08 519 157 4.50 / 257.09 5 78
7 8 0.00 229 15.06 338 1166 5.66 / 258.26 5 130
Average= 8.91
(KJ/cycle)

Cycle 46 GMT 30/ 3/2023 20:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 35 15.06 466 246 0.25 / 247.12 5 20
2 7 2008.72 40 14.70 3320 1952 2.20 / 249.08 20 62
3 13 1912.20 20 14.69 3175 933 3.13 / 250.01 5 64
4 13 1482.44 20 14.72 2573 757 3.89 / 250.77 5 72
5 13 813.16 20 14.86 1604 477 4.36 / 251.24 5 83
6 13 147.92 20 15.07 597 180 4.54 / 251.42 5 82
7 8 0.08 229 15.06 339 1169 5.71 / 252.59 5 129
Average= 9.02
(KJ/cycle)

Cycle 45 GMT 20/ 3/2023 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 35 15.06 476 251 0.25 / 241.48 5 19
2 7 2013.88 40 14.70 3326 1956 2.21 / 243.44 19 60
3 13 1922.68 20 14.69 3201 940 3.15 / 244.38 5 65
4 13 1293.20 20 14.76 2300 679 3.83 / 245.06 5 74
5 13 868.92 20 14.84 1687 501 4.33 / 245.56 5 84
6 13 104.44 20 15.09 521 157 4.48 / 245.71 5 78
7 8 0.16 231 15.06 335 1165 5.65 / 246.88 5 135
Average= 9.14
(KJ/cycle)

Cycle 44 GMT 11/ 3/2023 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 35 15.07 478 252 0.25 / 235.78 5 18
2 7 2013.88 40 14.70 3326 1956 2.21 / 237.74 18 61
3 13 1922.24 20 14.69 3207 942 3.15 / 238.68 5 64
4 13 1289.36 20 14.77 2300 679 3.83 / 239.36 5 75
5 13 947.60 20 14.83 1792 532 4.36 / 239.89 5 83
6 13 80.64 20 15.10 483 146 4.51 / 240.04 5 77
7 8 0.08 231 15.06 343 1193 5.70 / 241.23 5 130
Average= 9.28
(KJ/cycle)

Cycle 43 GMT 1/ 3/2023 4:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 35 15.07 471 248 0.25 / 230.20 5 19
2 7 2014.48 40 14.70 3331 1959 2.21 / 232.16 19 61
3 13 1920.96 20 14.70 3184 936 3.14 / 233.10 5 64
4 13 1188.16 20 14.80 2154 638 3.78 / 233.73 5 77
5 13 865.16 20 14.85 1673 497 4.28 / 234.23 5 82
6 13 41.68 20 15.12 412 125 4.40 / 234.36 5 74
7 8 0.12 231 15.07 337 1173 5.58 / 235.53 5 136
Average= 9.42
(KJ/cycle)

Cycle 42 GMT 19/ 2/2023 7:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 35 15.07 494 261 0.26 / 224.50 5 21
2 7 2009.32 40 14.71 3312 1949 2.21 / 226.45 21 61
3 13 1916.56 20 14.70 3193 939 3.15 / 227.39 5 65
4 13 1471.72 20 14.74 2560 755 3.90 / 228.15 5 73
5 13 811.32 20 14.88 1597 475 4.38 / 228.62 5 84
6 13 81.72 20 15.11 487 147 4.53 / 228.77 5 76
7 8 0.00 229 15.08 343 1184 5.71 / 229.95 5 131
Average= 9.58
(KJ/cycle)

Cycle 41 GMT 9/ 2/2023 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 35 15.08 479 253 0.25 / 218.74 5 21
2 7 2009.92 41 14.71 3315 1999 2.25 / 220.73 21 61
3 13 1935.76 20 14.69 3212 944 3.20 / 221.68 5 65
4 13 1507.00 20 14.72 2607 768 3.96 / 222.45 5 70
5 13 861.96 20 14.86 1680 499 4.46 / 222.95 5 85
6 13 46.56 20 15.13 423 128 4.59 / 223.07 5 73
7 8 0.12 229 15.08 339 1171 5.76 / 224.24 5 129
Average= 9.75
(KJ/cycle)

Cycle 40 GMT 30/ 1/2023 13:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 35 15.07 480 253 0.25 / 213.19 5 22
2 7 2010.28 40 14.71 3308 1946 2.20 / 215.13 22 61
3 13 1813.96 20 14.72 3041 895 3.09 / 216.03 5 67
4 13 1404.68 20 14.75 2459 725 3.82 / 216.75 5 73
5 13 650.60 20 14.93 1362 407 4.23 / 217.16 5 86
6 13 105.60 20 15.11 519 157 4.38 / 217.32 5 78
7 8 0.12 231 15.08 335 1167 5.55 / 218.48 5 131
Average= 9.93
(KJ/cycle)

Cycle 39 GMT 20/ 1/2023 16:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 35 15.08 472 249 0.25 / 207.59 5 21
2 7 2013.64 40 14.71 3323 1955 2.20 / 209.54 21 59
3 13 1720.48 20 14.74 2912 858 3.06 / 210.40 5 68
4 13 1307.32 20 14.78 2324 687 3.75 / 211.09 5 75
5 13 755.52 20 14.90 1519 453 4.20 / 211.54 5 85
6 13 187.00 20 15.08 659 199 4.40 / 211.74 5 84
7 8 0.08 229 15.08 345 1191 5.59 / 212.93 5 132
Average= 10.14
(KJ/cycle)

Cycle 38 GMT 10/ 1/2023 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 35 15.08 477 252 0.25 / 201.89 5 23
2 7 2009.48 41 14.72 3306 1995 2.25 / 203.89 23 61
3 13 1814.80 20 14.73 3039 895 3.14 / 204.78 5 66
4 13 1395.44 20 14.76 2452 724 3.87 / 205.51 5 71
5 13 840.56 20 14.88 1645 490 4.36 / 205.99 5 83
6 13 82.00 20 15.13 481 146 4.50 / 206.14 5 73
7 8 0.16 231 15.09 344 1199 5.70 / 207.34 5 132
Average= 10.37
(KJ/cycle)

Cycle 37 GMT 31/12/2022 22:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 35 15.08 500 264 0.26 / 196.24 5 24
2 7 2007.76 40 14.72 3304 1945 2.21 / 198.18 24 61
3 13 1923.12 20 14.71 3191 939 3.15 / 199.12 5 65
4 13 1403.56 20 14.77 2452 724 3.87 / 199.85 5 72
5 13 775.12 20 14.91 1547 461 4.33 / 200.31 5 84
6 13 113.56 20 15.12 535 162 4.50 / 200.47 5 77
7 8 0.16 229 15.09 338 1168 5.66 / 201.64 5 132
Average= 10.61
(KJ/cycle)

Cycle 36 GMT 22/12/2022 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 35 15.08 501 264 0.26 / 190.56 5 25
2 7 2006.92 40 14.73 3316 1954 2.22 / 192.51 25 59
3 13 1927.16 20 14.71 3215 946 3.16 / 193.46 5 64
4 13 1396.84 20 14.78 2446 723 3.89 / 194.18 5 72
5 13 731.16 20 14.92 1478 441 4.33 / 194.62 5 85
6 13 94.40 20 15.13 507 153 4.48 / 194.78 5 77
7 8 0.16 231 15.09 344 1199 5.68 / 195.98 5 132
Average= 10.89
(KJ/cycle)

Cycle 35 GMT 12/12/2022 3:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 35 15.08 494 261 0.26 / 184.84 5 27
2 7 2003.48 40 14.73 3310 1950 2.21 / 186.79 27 61
3 13 1916.32 20 14.72 3186 938 3.15 / 187.73 5 65
4 13 1400.60 20 14.78 2460 727 3.88 / 188.45 5 73
5 13 856.12 20 14.89 1664 496 4.37 / 188.95 5 83
6 13 89.72 20 15.13 502 152 4.52 / 189.10 5 77
7 8 0.12 232 15.10 341 1195 5.72 / 190.29 5 136
Average= 11.19
(KJ/cycle)

Cycle 34 GMT 2/12/2022 6:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 35 15.10 483 255 0.26 / 179.18 5 25
2 7 2003.40 40 14.73 3308 1949 2.20 / 181.13 25 61
3 13 1911.40 20 14.73 3178 936 3.14 / 182.07 5 65
4 13 1280.12 20 14.81 2282 676 3.82 / 182.74 5 75
5 13 842.88 20 14.89 1655 493 4.31 / 183.24 5 83
6 13 81.00 20 15.14 484 147 4.46 / 183.38 5 75
7 8 0.12 231 15.10 342 1193 5.65 / 184.58 5 133
Average= 11.54
(KJ/cycle)

Cycle 33 GMT 22/11/2022 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 35 15.09 508 268 0.27 / 173.41 5 28
2 7 2011.32 40 14.72 3327 1959 2.23 / 175.37 28 61
3 13 1919.36 20 14.72 3192 940 3.17 / 176.31 5 65
4 13 1384.44 20 14.78 2429 718 3.88 / 177.03 5 75
5 13 926.44 20 14.87 1773 527 4.41 / 177.55 5 84
6 13 145.04 20 15.12 593 179 4.59 / 177.73 5 80
7 8 0.00 231 15.11 342 1194 5.79 / 178.93 5 137
Average= 11.93
(KJ/cycle)

Cycle 32 GMT 12/11/2022 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 35 15.10 499 264 0.26 / 167.70 5 28
2 7 2008.80 40 14.73 3317 1954 2.22 / 169.65 28 61
3 13 1930.36 20 14.72 3210 945 3.16 / 170.60 5 63
4 13 1488.68 20 14.76 2574 760 3.92 / 171.36 5 71
5 13 713.56 20 14.94 1466 438 4.36 / 171.79 5 87
6 13 82.56 20 15.15 490 148 4.51 / 171.94 5 76
7 8 0.08 231 15.11 344 1201 5.71 / 173.14 5 136
Average= 12.37
(KJ/cycle)

Cycle 31 GMT 2/11/2022 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 35 15.09 502 265 0.27 / 162.04 5 30
2 7 2003.56 40 14.73 3317 1954 2.22 / 163.99 30 63
3 13 1913.96 20 14.73 3185 938 3.16 / 164.93 5 65
4 13 1373.28 20 14.80 2420 716 3.87 / 165.65 5 75
5 13 722.64 20 14.95 1480 443 4.32 / 166.09 5 85
6 13 86.96 20 15.15 498 151 4.47 / 166.24 5 77
7 8 0.08 227 15.11 348 1194 5.66 / 167.43 5 132
Average= 12.88
(KJ/cycle)

Cycle 30 GMT 23/10/2022 17:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 35 15.11 502 265 0.27 / 156.12 5 28
2 7 2013.92 40 14.74 3328 1962 2.23 / 158.08 28 60
3 13 1922.56 20 14.73 3213 947 3.17 / 159.03 5 64
4 13 1370.24 20 14.80 2414 715 3.89 / 159.74 5 76
5 13 825.52 20 14.92 1626 485 4.37 / 160.23 5 85
6 13 475.24 20 15.00 1106 332 4.71 / 160.56 5 90
7 8 0.08 229 15.10 350 1210 5.92 / 161.77 5 134
Average= 13.48
(KJ/cycle)

Cycle 29 GMT 13/10/2022 20:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 35 15.10 503 266 0.27 / 150.43 5 30
2 7 2005.60 40 14.73 3314 1953 2.22 / 152.38 30 61
3 13 1916.44 20 14.73 3193 941 3.16 / 153.32 5 67
4 13 1480.60 20 14.77 2581 762 3.92 / 154.09 5 74
5 13 686.36 20 14.96 1422 425 4.35 / 154.51 5 86
6 13 66.96 20 15.16 461 140 4.49 / 154.65 5 74
7 8 0.08 230 15.12 346 1203 5.69 / 155.86 5 135
Average= 14.17
(KJ/cycle)

Cycle 28 GMT 3/10/2022 23:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 35 15.11 502 265 0.27 / 144.69 5 31
2 7 2014.36 40 14.74 3320 1957 2.22 / 146.65 31 62
3 13 1925.20 20 14.74 3189 940 3.16 / 147.59 5 64
4 13 1486.80 20 14.78 2581 763 3.93 / 148.35 5 73
5 13 801.20 20 14.93 1587 474 4.40 / 148.83 5 85
6 13 70.28 20 15.16 470 143 4.54 / 148.97 5 76
7 8 0.00 229 15.12 345 1195 5.74 / 150.17 5 132
Average= 15.02
(KJ/cycle)

Cycle 27 GMT 24/ 9/2022 2:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 35 15.11 502 265 0.27 / 139.03 5 29
2 7 2004.12 40 14.74 3321 1958 2.22 / 140.99 29 62
3 13 1909.12 20 14.74 3192 941 3.16 / 141.93 5 65
4 13 1269.76 20 14.84 2260 671 3.84 / 142.60 5 78
5 13 730.40 20 14.96 1483 444 4.28 / 143.05 5 83
6 13 156.24 20 15.14 612 185 4.46 / 143.23 5 81
7 8 0.04 227 15.13 348 1195 5.66 / 144.43 5 131
Average= 16.05
(KJ/cycle)

Cycle 26 GMT 14/ 9/2022 5:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 35 15.13 492 261 0.26 / 133.40 5 29
2 7 2004.84 40 14.75 3323 1961 2.22 / 135.36 29 61
3 13 1911.72 20 14.75 3183 939 3.16 / 136.30 5 66
4 13 1371.48 20 14.82 2417 716 3.88 / 137.02 5 78
5 13 708.68 20 14.97 1452 435 4.31 / 137.45 5 87
6 13 34.12 20 15.18 405 123 4.43 / 137.58 5 74
7 8 0.00 227 15.13 347 1192 5.63 / 138.77 5 134
Average= 17.35
(KJ/cycle)

Cycle 25 GMT 4/ 9/2022 8:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 35 15.12 510 270 0.27 / 127.78 5 31
2 7 2007.56 40 14.76 3321 1961 2.23 / 129.74 31 62
3 13 1925.80 20 14.75 3192 942 3.17 / 130.68 5 67
4 13 1202.80 20 14.87 2165 644 3.82 / 131.32 5 80
5 13 882.44 20 14.91 1699 507 4.32 / 131.83 5 85
6 8 0.16 250 15.14 347 1313 5.64 / 133.14 5 134
Average= 19.02
(KJ/cycle)

Cycle 24 GMT 25/ 8/2022 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 35 15.12 506 268 0.27 / 122.00 5 31
2 7 2006.24 40 14.76 3314 1957 2.22 / 123.96 31 61
3 13 1917.64 20 14.76 3194 943 3.17 / 124.90 5 65
4 13 1295.44 20 14.84 2298 682 3.85 / 125.59 5 75
5 13 970.96 20 14.89 1841 548 4.40 / 126.13 5 83
6 13 113.16 20 15.17 536 163 4.56 / 126.30 5 78
7 8 0.04 229 15.14 349 1210 5.77 / 127.51 5 135
Average= 21.25
(KJ/cycle)

Cycle 23 GMT 15/ 8/2022 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 35 15.13 502 266 0.27 / 116.34 5 29
2 7 2011.80 40 14.76 3318 1959 2.22 / 118.29 29 61
3 13 1921.12 20 14.76 3189 941 3.17 / 119.24 5 66
4 13 1288.12 20 14.85 2297 682 3.85 / 119.92 5 77
5 13 754.88 20 14.96 1520 455 4.30 / 120.37 5 86
6 13 97.16 20 15.17 517 157 4.46 / 120.53 5 78
7 8 0.12 229 15.14 348 1207 5.67 / 121.74 5 134
Average= 24.35
(KJ/cycle)

Cycle 22 GMT 5/ 8/2022 16:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 35 15.13 497 263 0.26 / 110.71 5 30
2 7 2005.20 40 14.76 3315 1957 2.22 / 112.67 30 61
3 13 1919.20 20 14.76 3198 944 3.16 / 113.61 5 66
4 13 1279.76 20 14.85 2288 680 3.84 / 114.29 5 79
5 13 745.40 20 14.97 1511 452 4.30 / 114.75 5 87
6 13 44.72 20 15.19 430 131 4.43 / 114.88 5 75
7 8 0.08 227 15.14 347 1193 5.62 / 116.07 5 134
Average= 29.02
(KJ/cycle)

Cycle 21 GMT 26/ 7/2022 19:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 35 15.14 484 256 0.26 / 105.02 5 29
2 7 2008.76 40 14.77 3320 1961 2.22 / 106.98 29 62
3 13 1910.08 20 14.76 3191 942 3.16 / 107.92 5 67
4 13 1276.88 20 14.86 2275 676 3.84 / 108.60 5 77
5 13 851.84 20 14.94 1651 493 4.33 / 109.09 5 85
6 13 70.80 20 15.19 478 145 4.47 / 109.24 5 78
7 8 0.12 229 15.15 350 1214 5.69 / 110.45 5 134
Average= 36.82
(KJ/cycle)

Cycle 20 GMT 16/ 7/2022 22:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 35 15.14 494 262 0.26 / 99.40 5 28
2 7 2008.56 40 14.77 3330 1967 2.23 / 101.37 28 60
3 13 1811.08 20 14.79 3039 899 3.13 / 102.27 5 68
4 13 1282.44 20 14.86 2287 680 3.81 / 102.95 5 77
5 13 743.80 20 14.97 1506 451 4.26 / 103.40 5 87
6 13 86.20 20 15.18 500 152 4.41 / 103.55 5 79
7 8 0.04 227 15.15 352 1211 5.62 / 104.76 5 131
Average= 52.38
(KJ/cycle)

Cycle 19 GMT 7/ 7/2022 1: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 35 15.15 478 253 0.25 / 93.67 5 27
2 7 2009.84 40 14.78 3308 1956 2.21 / 95.62 27 60
3 13 1918.28 20 14.77 3197 944 3.15 / 96.57 5 65
4 13 1381.64 20 14.85 2423 720 3.87 / 97.29 5 75
5 13 829.20 20 14.96 1620 485 4.36 / 97.77 5 85
6 13 90.32 20 15.19 511 155 4.51 / 97.93 5 77
7 8 0.08 229 15.16 349 1212 5.72 / 99.14 5 132
Average= 99.14
(KJ/cycle)

Cycle 17 GMT 17/ 6/2022 6:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 35 15.15 497 264 0.26 / 88.09 5 27
2 7 2005.92 40 14.79 3312 1959 2.22 / 90.05 27 61
3 13 1920.52 20 14.78 3185 941 3.16 / 90.99 5 65
4 13 1278.56 20 14.87 2285 680 3.84 / 91.67 5 78
5 13 632.04 20 15.03 1336 402 4.25 / 92.07 5 87
6 13 89.64 20 15.20 500 152 4.40 / 92.22 5 79
7 8 0.12 227 15.16 347 1194 5.59 / 93.42 5 133
Average= 5.19
(KJ/cycle)

Cycle 16 GMT 7/ 6/2022 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 34 15.15 491 253 0.25 / 82.36 5 27
2 7 2003.76 40 14.79 3322 1965 2.22 / 84.33 27 61
3 13 1914.80 20 14.78 3199 946 3.16 / 85.27 5 65
4 13 1377.92 20 14.86 2419 719 3.88 / 85.99 5 76
5 13 828.36 20 14.97 1631 488 4.37 / 86.48 5 85
6 13 72.48 20 15.20 474 144 4.52 / 86.62 5 78
7 8 0.08 229 15.17 346 1202 5.72 / 87.82 5 132
Average= 5.17
(KJ/cycle)

Cycle 15 GMT 28/ 5/2022 12:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 34 15.16 495 255 0.26 / 76.57 5 23
2 7 2012.76 40 14.78 3311 1957 2.21 / 78.53 23 60
3 13 1915.36 20 14.79 3195 945 3.16 / 79.47 5 65
4 13 1602.56 20 14.81 2730 809 3.97 / 80.28 5 73
5 13 802.36 20 14.98 1597 478 4.44 / 80.76 5 86
6 13 63.76 20 15.21 465 141 4.59 / 80.90 5 76
7 8 0.16 227 15.17 350 1205 5.79 / 82.11 5 131
Average= 5.13
(KJ/cycle)

Cycle 14 GMT 18/ 5/2022 15:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 34 15.16 494 255 0.25 / 70.91 5 24
2 7 2010.24 40 14.80 3313 1961 2.22 / 72.87 24 61
3 13 1918.08 20 14.79 3195 945 3.16 / 73.81 5 66
4 13 1366.80 20 14.86 2414 717 3.88 / 74.53 5 78
5 13 728.68 20 15.00 1486 446 4.32 / 74.98 5 86
6 13 44.16 20 15.22 429 131 4.45 / 75.11 5 76
7 8 0.04 227 15.17 351 1209 5.66 / 76.32 5 133
Average= 5.09
(KJ/cycle)

Cycle 13 GMT 8/ 5/2022 18:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 34 15.16 478 246 0.25 / 65.19 5 23
2 7 2004.20 41 14.79 3321 2014 2.26 / 67.20 23 61
3 13 1912.96 20 14.80 3197 946 3.21 / 68.15 5 65
4 13 1357.00 20 14.87 2393 712 3.92 / 68.86 5 77
5 13 685.84 20 15.02 1428 429 4.35 / 69.29 5 87
6 13 117.00 20 15.20 548 167 4.51 / 69.45 5 81
7 8 0.12 227 15.17 348 1198 5.71 / 70.65 5 132
Average= 5.05
(KJ/cycle)

Cycle 12 GMT 28/ 4/2022 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 34 15.17 483 249 0.25 / 59.50 5 23
2 7 2012.28 40 14.80 3319 1965 2.21 / 61.47 23 61
3 13 1918.52 20 14.80 3189 944 3.16 / 62.41 5 66
4 13 1276.16 20 14.89 2277 678 3.84 / 63.09 5 77
5 13 751.44 20 15.00 1521 456 4.29 / 63.54 5 86
6 13 174.32 20 15.18 648 197 4.49 / 63.74 5 84
7 8 0.16 227 15.17 348 1198 5.69 / 64.94 5 131
Average= 5.00
(KJ/cycle)

Cycle 11 GMT 19/ 4/2022 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 34 15.17 489 252 0.25 / 53.84 5 22
2 7 2007.40 40 14.81 3300 1955 2.21 / 55.80 22 62
3 13 1919.64 20 14.81 3187 944 3.15 / 56.74 5 65
4 13 1370.72 20 14.88 2403 715 3.87 / 57.46 5 75
5 13 727.52 20 15.01 1486 446 4.31 / 57.90 5 88
6 13 52.68 20 15.23 449 137 4.45 / 58.04 5 77
7 8 0.08 231 15.18 346 1213 5.66 / 59.25 5 138
Average= 4.94
(KJ/cycle)

Cycle 10 GMT 9/ 4/2022 2:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 34 15.17 501 258 0.26 / 48.17 5 20
2 7 2014.92 40 14.81 3309 1960 2.22 / 50.13 20 61
3 13 1922.20 20 14.81 3189 945 3.16 / 51.08 5 66
4 13 1372.68 20 14.88 2406 716 3.88 / 51.79 5 75
5 13 706.44 20 15.02 1441 433 4.31 / 52.23 5 87
6 13 79.24 20 15.22 493 150 4.46 / 52.38 5 79
7 8 0.12 229 15.18 349 1213 5.68 / 53.59 5 137
Average= 4.87
(KJ/cycle)

Cycle 9 GMT 30/ 3/2022 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 34 15.18 488 252 0.25 / 42.31 5 20
2 7 2006.88 40 14.82 3316 1966 2.22 / 44.28 20 62
3 13 1915.56 20 14.82 3193 946 3.16 / 45.23 5 66
4 13 1394.80 20 14.87 2445 727 3.89 / 45.95 5 75
5 13 1055.80 20 14.92 1962 585 4.48 / 46.54 5 83
6 13 99.84 20 15.21 526 160 4.64 / 46.70 5 81
7 8 0.16 231 15.18 347 1217 5.85 / 47.91 5 131
Average= 4.79
(KJ/cycle)

Cycle 8 GMT 20/ 3/2022 8:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 34 15.17 489 252 0.25 / 36.55 5 21
2 7 2013.12 41 14.82 3299 2005 2.26 / 38.56 57 62
3 13 1915.80 20 14.81 3179 942 3.20 / 39.50 5 65
4 13 1464.52 20 14.86 2543 756 3.95 / 40.25 5 75
5 13 805.92 20 14.99 1600 480 4.43 / 40.73 5 86
6 13 35.04 20 15.24 420 128 4.56 / 40.86 5 76
7 8 0.16 227 15.19 348 1200 5.76 / 42.06 5 132
Average= 4.67
(KJ/cycle)

Cycle 7 GMT 10/ 3/2022 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 34 15.18 481 248 0.25 / 30.95 5 19
2 7 2011.72 40 14.83 3305 1961 2.21 / 32.91 19 62
3 13 1811.76 20 14.84 3040 902 3.11 / 33.81 5 67
4 13 1291.60 20 14.90 2294 684 3.79 / 34.49 5 77
5 13 658.56 20 15.04 1383 416 4.21 / 34.91 5 86
6 13 100.80 20 15.21 529 161 4.37 / 35.07 5 81
7 13 19.36 20 15.23 395 120 4.49 / 35.19 5 77
8 8 0.08 208 15.18 351 1108 5.60 / 36.30 5 130
Average= 4.54
(KJ/cycle)

Cycle 6 GMT 28/ 2/2022 14:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 33 15.18 496 248 0.25 / 25.30 5 20
2 3 1037.80 1 15.19 1934 29 0.28 / 25.33 5 69
3 7 2004.88 41 14.83 3301 2007 2.28 / 27.33 69 62
4 13 1918.20 20 14.82 3175 941 3.23 / 28.27 5 65
5 13 1280.08 20 14.91 2281 680 3.91 / 28.95 5 77
6 13 643.36 20 15.05 1361 410 4.32 / 29.36 5 87
7 13 40.28 20 15.24 432 132 4.45 / 29.50 5 76
8 8 0.08 229 15.19 346 1204 5.65 / 30.70 5 138
Average= 4.39
(KJ/cycle)

Cycle 5 GMT 18/ 2/2022 17: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 31 15.18 496 233 0.23 / 19.56 5 20
2 3 1081.96 2 15.15 2008 61 0.29 / 19.62 5 72
3 7 2012.04 41 14.83 3311 2013 2.31 / 21.63 72 63
4 13 1916.68 20 14.83 3195 948 3.26 / 22.58 5 65
5 13 1352.52 20 14.90 2384 710 3.97 / 23.29 5 76
6 13 686.00 20 15.04 1421 427 4.39 / 23.72 5 87
7 13 54.28 20 15.23 444 135 4.53 / 23.85 5 76
8 8 0.12 227 15.19 347 1197 5.72 / 25.05 5 130
Average= 4.17
(KJ/cycle)

Cycle 4 GMT 8/ 2/2022 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 33 15.18 490 245 0.25 / 14.60 5 22
2 7 1504.88 40 14.98 2605 1561 1.81 / 16.16 54 69
3 13 1430.20 20 14.98 2490 746 2.55 / 16.90 5 71
4 13 1335.20 20 14.94 2357 704 3.26 / 17.61 5 75
5 13 627.12 20 15.08 1335 403 3.66 / 18.01 5 87
6 13 20.76 20 15.26 396 121 3.78 / 18.13 5 75
7 8 0.04 225 15.20 349 1194 4.97 / 19.32 5 136
Average= 3.86
(KJ/cycle)

Cycle 3 GMT 7/ 2/2022 9:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 32 15.18 479 233 0.23 / 9.85 5 19
2 7 1514.16 40 14.98 2603 1560 1.79 / 11.41 19 68
3 13 1442.16 20 14.98 2491 746 2.54 / 12.15 5 70
4 13 1039.48 20 15.01 1934 581 3.12 / 12.73 5 79
5 13 400.80 20 15.15 996 302 3.42 / 13.03 5 85
6 13 19.16 20 15.26 388 118 3.54 / 13.15 5 75
7 8 0.08 225 15.20 350 1197 4.74 / 14.35 5 140
Average= 3.59
(KJ/cycle)

Cycle 2 GMT 5/ 2/2022 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 31 15.21 504 238 0.24 / 4.99 5 20
2 3 1059.24 1 15.20 1958 30 0.27 / 5.02 5 70
3 7 1512.72 40 14.99 2596 1557 1.82 / 6.58 70 68
4 13 1444.52 20 14.98 2492 747 2.57 / 7.32 5 71
5 13 1139.80 20 14.99 2065 619 3.19 / 7.94 5 77
6 13 499.60 20 15.12 1145 346 3.54 / 8.29 5 86
7 13 33.00 20 15.25 420 128 3.66 / 8.42 5 75
8 8 0.16 225 15.20 350 1197 4.86 / 9.61 5 133
Average= 3.20
(KJ/cycle)

Cycle 1 GMT 4/ 2/2022 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 31 15.44 472 226 0.23 / 1.93 5 16
2 3 1044.56 1 15.24 1945 30 0.26 / 1.96 5 69
3 7 1013.32 40 15.11 1867 1128 1.38 / 3.09 69 74
4 13 482.72 20 15.21 1114 339 1.72 / 3.43 5 83
5 13 34.04 20 15.31 417 128 1.85 / 3.56 5 74
6 8 -0.04 225 15.26 348 1195 3.05 / 4.75 5 133
Average= 2.38
(KJ/cycle)

Cycle 0 GMT 4/ 2/2022 2:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 30 15.62 428 201 0.20 / 0.20 5 16
2 7 124.72 40 15.60 435 271 0.47 / 0.47 16 24
3 13 72.60 20 15.59 361 113 0.58 / 0.58 5 26
4 13 18.48 20 15.58 303 94 0.68 / 0.68 5 35
5 8 0.16 229 15.53 289 1028 1.71 / 1.71 5 -99
Average= 1.71
(KJ/cycle)