Cycle 33 GMT 28/11/2024 12:44: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.4 8 87 15.11 354 465 0.47 / 561.39 3 7
2 6 5902.6 802 68 14.62 3821 3799 4.26 / 565.19 3 32
3 3 5353.2 1042 3 14.91 3643 163 4.43 / 565.36 3 35
4 7 5296.2 12002 80 14.88 3497 4163 8.59 / 569.52 3 42
5 13 4371.6 12224 80 14.76 2966 3502 12.09 / 573.02 3 44
6 13 3160.4 12488 80 14.87 2264 2693 14.79 / 575.71 3 45
7 13 1991.1 12716 80 15.00 1568 1882 16.67 / 577.60 3 49
8 13 1093.5 12872 80 15.10 1028 1242 17.91 / 578.84 3 49
9 13 791.1 12914 80 15.11 831 1005 18.91 / 579.84 3 45
10 13 734.1 12920 80 15.06 799 963 19.88 / 580.80 3 87
11 14 0.7 12995 96 15.12 318 462 20.34 / 581.27 3 101
12 14 1.1 12996 4 15.11 333 20 20.36 / 581.29 4 48
Average= 17.10
(KJ/cycle)

Cycle 32 GMT 18/11/2024 14:33: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.1 8 88 15.11 351 467 0.47 / 541.17 3 6
2 6 5870.0 797 68 14.62 3797 3775 4.24 / 544.95 3 33
3 7 5317.7 12002 80 14.88 3480 4143 8.38 / 549.09 3 43
4 13 4380.1 12230 80 14.76 2972 3509 11.89 / 552.60 3 43
5 13 3146.8 12500 80 14.88 2262 2693 14.59 / 555.29 3 45
6 13 1982.8 12734 80 15.01 1561 1874 16.46 / 557.17 3 46
7 13 1140.7 12878 80 15.10 1054 1273 17.73 / 558.44 3 49
8 13 787.5 12926 80 15.11 832 1006 18.74 / 559.45 3 45
9 13 734.2 12932 80 15.06 796 959 19.70 / 560.41 3 78
10 14 0.9 13008 108 15.12 320 523 20.22 / 560.93 3 104
Average= 17.00
(KJ/cycle)

Cycle 31 GMT 8/11/2024 16:14: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.0 8 88 15.11 353 469 0.47 / 520.67 3 6
2 6 5907.9 798 69 14.62 3820 3854 4.32 / 524.53 3 34
3 3 5321.4 1039 1 14.94 3486 52 4.37 / 524.58 3 34
4 7 5312.7 12002 80 14.89 3497 4166 8.54 / 528.75 3 40
5 13 4372.6 12230 80 14.77 2987 3529 12.07 / 532.28 3 44
6 13 3096.8 12512 80 14.89 2238 2666 14.74 / 534.94 3 45
7 13 1996.4 12728 80 15.00 1582 1898 16.63 / 536.84 3 48
8 13 1135.2 12878 80 15.10 1045 1262 17.90 / 538.10 3 48
9 13 921.4 12908 80 15.09 919 1109 19.01 / 539.21 3 48
10 13 732.4 12929 80 15.07 798 962 19.97 / 540.17 3 81
11 14 0.9 13007 110 15.12 321 534 20.50 / 540.71 3 102
Average= 16.90
(KJ/cycle)

Cycle 30 GMT 29/10/2024 17:54: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.3 8 87 15.12 353 464 0.46 / 500.15 3 5
2 6 5888.1 779 69 14.62 3812 3845 4.31 / 503.99 3 34
3 3 5345.4 1020 2 14.91 3657 109 4.42 / 504.10 3 36
4 7 5333.7 12002 80 14.89 3471 4135 8.55 / 508.23 3 40
5 13 4326.7 12248 80 14.78 2941 3477 12.03 / 511.71 3 44
6 13 3166.9 12500 80 14.88 2261 2691 14.72 / 514.40 3 45
7 13 1998.7 12740 80 15.01 1572 1888 16.61 / 516.29 3 46
8 13 1119.2 12896 80 15.11 1035 1251 17.86 / 517.54 3 47
9 13 992.6 12914 80 15.08 962 1161 19.02 / 518.70 3 50
10 13 730.9 12943 80 15.07 792 955 19.98 / 519.66 3 62
11 14 0.7 13022 114 15.12 318 548 20.52 / 520.21 3 102
Average= 16.78
(KJ/cycle)

Cycle 29 GMT 19/10/2024 19:38:59

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.9 8 88 15.12 355 472 0.47 / 479.62 3 6
2 6 5875.0 791 68 14.63 3817 3797 4.27 / 483.42 3 34
3 3 5331.4 1032 1 14.91 3648 54 4.32 / 483.48 3 35
4 7 5320.5 12002 80 14.89 3501 4170 8.49 / 487.65 3 42
5 13 4459.7 12206 80 14.77 3012 3559 12.05 / 491.20 3 43
6 13 3012.7 12524 80 14.92 2169 2589 14.64 / 493.79 3 47
7 13 1988.1 12740 80 15.02 1572 1889 16.53 / 495.68 3 48
8 13 1272.1 12860 80 15.08 1131 1364 17.90 / 497.05 3 50
9 13 963.6 12902 80 15.08 941 1135 19.03 / 498.18 3 50
10 13 719.3 12929 80 15.08 788 951 19.98 / 499.13 3 85
11 14 0.6 13007 116 15.13 312 548 20.53 / 499.68 3 102
Average= 16.66
(KJ/cycle)

Cycle 28 GMT 9/10/2024 21:26: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.1 8 87 15.13 350 461 0.46 / 459.26 3 6
2 6 5865.9 794 68 14.64 3778 3761 4.22 / 463.02 3 34
3 3 5342.4 1035 2 14.95 3403 102 4.32 / 463.12 3 33
4 7 5338.9 12002 80 14.90 3489 4159 8.48 / 467.28 3 39
5 13 4386.8 12224 80 14.79 2971 3515 12.00 / 470.79 3 41
6 13 3136.3 12500 80 14.91 2246 2679 14.68 / 473.47 3 45
7 13 1982.9 12734 80 15.03 1557 1872 16.55 / 475.35 3 47
8 13 1120.3 12884 80 15.12 1043 1262 17.81 / 476.61 3 49
9 13 861.4 12920 80 15.11 871 1053 18.86 / 477.66 3 47
10 13 729.1 12935 80 15.08 788 951 19.81 / 478.61 3 79
11 14 1.4 13013 112 15.13 319 541 20.35 / 479.15 3 101
Average= 16.52
(KJ/cycle)

Cycle 27 GMT 29/ 9/2024 23: 2: 3

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.8 8 87 15.13 348 458 0.46 / 438.90 3 5
2 6 5897.3 803 68 14.65 3786 3772 4.23 / 442.67 3 34
3 3 5340.4 1044 2 14.97 3416 102 4.33 / 442.77 3 36
4 7 5316.4 12002 80 14.90 3499 4171 8.50 / 446.94 3 40
5 13 4339.3 12230 80 14.81 2936 3479 11.98 / 450.42 3 45
6 13 3082.0 12512 80 14.92 2217 2646 14.63 / 453.06 3 46
7 13 1988.2 12734 80 15.03 1562 1878 16.51 / 454.94 3 49
8 13 1061.5 12896 80 15.13 1007 1219 17.72 / 456.16 3 49
9 13 932.5 12914 80 15.10 920 1111 18.84 / 457.27 3 49
10 13 742.0 12935 80 15.08 803 969 19.80 / 458.24 3 71
11 14 0.7 13016 115 15.14 319 555 20.36 / 458.80 3 102
Average= 16.39
(KJ/cycle)

Cycle 26 GMT 20/ 9/2024 0:34: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.7 8 88 15.14 357 476 0.48 / 418.51 3 6
2 6 5885.6 796 68 14.65 3806 3792 4.27 / 422.30 3 34
3 7 5328.2 12002 80 14.90 3514 4189 8.46 / 426.49 3 40
4 13 4401.6 12224 80 14.81 2969 3518 11.97 / 430.01 3 44
5 13 3055.8 12524 80 14.93 2209 2638 14.61 / 432.65 3 46
6 13 1992.9 12740 80 15.04 1567 1885 16.50 / 434.53 3 47
7 13 1145.5 12884 80 15.12 1065 1288 17.79 / 435.82 3 50
8 13 924.8 12914 80 15.11 921 1113 18.90 / 436.94 3 48
9 13 738.3 12935 80 15.09 797 962 19.86 / 437.90 3 78
10 14 0.8 13016 114 15.14 312 538 20.40 / 438.44 3 101
Average= 16.24
(KJ/cycle)

Cycle 25 GMT 10/ 9/2024 2: 8: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.6 8 87 15.15 347 457 0.46 / 398.07 3 6
2 6 5795.1 760 68 14.66 3745 3733 4.19 / 401.81 3 33
3 3 5339.2 1001 2 14.93 3689 110 4.30 / 401.92 3 34
4 7 5340.7 12002 80 14.90 3534 4213 8.51 / 406.13 3 40
5 13 4410.3 12230 80 14.82 2997 3553 12.07 / 409.68 3 42
6 13 3153.6 12500 80 14.92 2253 2689 14.76 / 412.37 3 45
7 13 2000.8 12734 80 15.04 1581 1902 16.66 / 414.27 3 48
8 13 1095.0 12896 80 15.14 1025 1241 17.90 / 415.52 3 48
9 13 882.8 12926 80 15.13 891 1078 18.98 / 416.59 3 47
10 13 730.8 12943 80 15.10 793 958 19.94 / 417.55 3 60
11 14 1.2 13021 101 15.15 317 485 20.42 / 418.04 3 100
Average= 16.08
(KJ/cycle)

Cycle 24 GMT 31/ 8/2024 4:14: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.1 8 87 15.15 350 461 0.46 / 377.77 3 6
2 6 5807.9 773 68 14.67 3747 3738 4.20 / 381.51 3 35
3 7 5348.8 12002 80 14.91 3506 4182 8.38 / 385.69 3 45
4 13 4429.0 12224 80 14.83 2999 3558 11.94 / 389.25 3 42
5 13 3163.7 12494 80 14.93 2267 2708 14.65 / 391.95 3 46
6 13 1989.7 12734 80 15.05 1560 1878 16.53 / 393.83 3 47
7 13 1134.5 12884 80 15.14 1043 1263 17.79 / 395.10 3 48
8 13 830.8 12926 80 15.15 852 1033 18.82 / 396.13 3 45
9 13 730.3 12937 80 15.11 795 961 19.78 / 397.09 3 69
10 14 0.6 13018 112 15.16 310 526 20.31 / 397.62 3 100
Average= 15.90
(KJ/cycle)

Cycle 23 GMT 21/ 8/2024 6:11: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.4 8 87 15.16 354 467 0.47 / 357.43 3 6
2 6 5874.8 782 69 14.66 3791 3835 4.30 / 361.26 3 34
3 3 5320.3 1023 1 14.91 3605 54 4.36 / 361.32 3 36
4 7 5311.3 12002 80 14.91 3494 4168 8.52 / 365.49 3 40
5 13 4398.3 12218 80 14.84 2979 3537 12.06 / 369.02 3 43
6 13 3121.9 12494 80 14.95 2243 2683 14.74 / 371.71 3 46
7 13 1993.5 12722 80 15.06 1573 1895 16.64 / 373.60 3 46
8 13 1068.3 12884 80 15.16 1004 1218 17.86 / 374.82 3 48
9 13 853.4 12914 80 15.14 875 1060 18.91 / 375.88 3 47
10 13 718.8 12929 80 15.11 785 949 19.86 / 376.83 3 85
11 14 0.9 13005 90 15.17 317 433 20.30 / 377.26 3 104
12 14 1.0 13005 10 15.16 321 49 20.35 / 377.31 6 68
Average= 15.72
(KJ/cycle)

Cycle 22 GMT 11/ 8/2024 8:12: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.2 8 87 15.15 345 455 0.45 / 336.97 3 6
2 6 5882.4 778 68 14.67 3792 3783 4.24 / 340.75 3 34
3 3 5340.6 1019 2 14.96 3535 106 4.34 / 340.86 3 33
4 7 5332.8 12002 80 14.91 3516 4194 8.54 / 345.05 3 42
5 13 4414.1 12218 80 14.85 2995 3558 12.10 / 348.61 3 42
6 13 3103.3 12500 80 14.96 2228 2666 14.76 / 351.28 3 46
7 13 1995.2 12722 80 15.06 1574 1896 16.66 / 353.17 3 47
8 13 1137.3 12872 80 15.15 1046 1268 17.93 / 354.44 3 50
9 13 879.2 12908 80 15.15 883 1070 19.00 / 355.51 3 50
10 13 745.9 12923 80 15.11 804 972 19.97 / 356.48 3 72
11 14 1.0 13003 96 15.17 315 459 20.43 / 356.94 3 100
12 14 1.4 13004 4 15.16 327 20 20.45 / 356.96 5 41
Average= 15.52
(KJ/cycle)

Cycle 21 GMT 1/ 8/2024 10:15: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.2 8 88 15.17 351 469 0.47 / 316.42 3 5
2 6 5623.8 721 68 14.69 3680 3676 4.14 / 320.10 3 35
3 7 5335.0 12002 80 14.91 3527 4207 8.35 / 324.30 3 38
4 13 4381.9 12236 80 14.86 2973 3534 11.89 / 327.84 3 45
5 13 3137.3 12500 80 14.96 2255 2699 14.58 / 330.54 3 45
6 13 1997.6 12734 80 15.07 1566 1888 16.47 / 332.43 3 47
7 13 1048.4 12902 80 15.18 989 1201 17.67 / 333.63 3 49
8 13 872.7 12926 80 15.16 882 1070 18.74 / 334.70 3 47
9 13 740.9 12941 80 15.12 798 965 19.71 / 335.66 3 69
10 13 2.8 13015 80 15.17 318 386 20.09 / 336.05 3 98
11 14 1.1 13021 41 15.17 321 200 20.29 / 336.25 3 111
12 14 1.5 13022 59 15.16 301 269 20.56 / 336.52 13 247
Average= 15.30
(KJ/cycle)

Cycle 20 GMT 22/ 7/2024 12:55: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.9 8 89 15.17 351 474 0.47 / 296.07 3 6
2 6 5831.7 771 68 14.69 3785 3781 4.25 / 299.85 3 34
3 7 5324.5 12002 80 14.92 3513 4193 8.45 / 304.04 3 38
4 13 4318.5 12248 80 14.87 2957 3518 11.97 / 307.56 3 45
5 13 3090.0 12530 80 14.97 2224 2663 14.63 / 310.23 3 44
6 13 1986.5 12746 80 15.08 1570 1894 16.52 / 312.12 3 48
7 13 1026.1 12914 80 15.19 981 1192 17.72 / 313.31 3 48
8 13 987.2 12920 80 15.13 953 1154 18.87 / 314.46 3 50
9 13 745.5 12947 80 15.13 808 978 19.85 / 315.44 3 64
10 14 0.8 13028 106 15.18 317 510 20.36 / 315.95 3 108
Average= 15.05
(KJ/cycle)

Cycle 19 GMT 12/ 7/2024 14:44: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.1 8 86 15.18 350 457 0.46 / 275.06 3 8
2 6 5903.1 783 69 14.68 3828 3877 4.33 / 278.94 3 34
3 3 5381.5 1024 4 14.94 3554 212 4.55 / 279.15 3 34
4 7 5341.9 12002 80 14.92 3527 4210 8.76 / 283.36 3 39
5 13 4549.7 12188 80 14.86 3075 3656 12.41 / 287.02 3 42
6 13 3183.3 12464 80 14.97 2284 2735 15.15 / 289.75 3 45
7 13 1985.9 12710 80 15.09 1562 1886 17.03 / 291.64 3 48
8 13 1231.6 12842 80 15.16 1099 1333 18.37 / 292.97 3 50
9 13 965.7 12878 80 15.15 942 1142 19.51 / 294.11 3 51
10 13 718.1 12905 80 15.14 784 950 20.46 / 295.06 3 63
11 14 0.7 12983 112 15.19 315 536 20.99 / 295.60 3 110
Average= 14.78
(KJ/cycle)

Cycle 18 GMT 2/ 7/2024 17: 5: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 8 86 15.18 349 456 0.46 / 254.56 3 7
2 6 5889.1 785 69 14.69 3809 3861 4.32 / 258.42 3 36
3 3 5345.5 1025 2 14.93 3673 110 4.43 / 258.53 3 33
4 7 5315.1 12002 80 14.93 3492 4171 8.60 / 262.70 3 39
5 13 4484.8 12200 80 14.87 3038 3614 12.21 / 266.31 3 44
6 13 3202.5 12470 80 14.97 2278 2728 14.94 / 269.04 3 47
7 13 1979.1 12710 80 15.09 1559 1882 16.82 / 270.92 3 49
8 13 1096.7 12860 80 15.18 1019 1237 18.06 / 272.16 3 50
9 13 768.0 12906 80 15.19 816 992 19.05 / 273.15 3 46
10 13 729.0 12910 80 15.14 795 963 20.01 / 274.11 3 74
11 14 1.3 12987 93 15.19 320 452 20.47 / 274.57 3 104
12 14 1.6 12987 7 15.19 339 36 20.50 / 274.60 5 57
Average= 14.45
(KJ/cycle)

Cycle 17 GMT 22/ 6/2024 19:19: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.3 8 86 15.19 351 459 0.46 / 234.14 3 6
2 6 5825.5 761 69 14.71 3762 3818 4.28 / 237.96 3 33
3 3 5329.6 1002 1 14.98 3438 52 4.33 / 238.01 3 30
4 7 5328.2 12002 80 14.93 3528 4214 8.54 / 242.23 3 40
5 13 4378.6 12224 80 14.89 2962 3528 12.07 / 245.76 3 44
6 13 3075.6 12512 80 14.99 2217 2659 14.73 / 248.41 3 46
7 13 1977.6 12734 80 15.10 1562 1887 16.62 / 250.30 3 49
8 13 1098.8 12884 80 15.19 1024 1244 17.86 / 251.55 3 50
9 13 921.0 12908 80 15.17 911 1106 18.97 / 252.65 3 51
10 13 740.0 12929 80 15.14 799 968 19.93 / 253.62 3 64
11 14 1.1 13009 91 15.20 317 438 20.37 / 254.06 3 104
12 14 1.5 13010 9 15.19 327 45 20.42 / 254.10 6 71
Average= 14.12
(KJ/cycle)

Cycle 16 GMT 12/ 6/2024 21:35: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.3 8 85 15.20 350 452 0.45 / 213.67 3 6
2 6 5781.0 753 68 14.71 3770 3771 4.22 / 217.44 3 33
3 3 5317.1 0 1 15.00 3622 54 4.28 / 217.50 3 34
4 7 5371.5 12363 80 14.93 3530 4216 8.49 / 221.71 3 40
5 13 4438.7 12597 80 14.89 3008 3583 12.08 / 225.30 3 43
6 13 3084.8 12885 80 15.00 2224 2669 14.75 / 227.97 3 46
7 13 1994.1 13119 80 15.11 1570 1898 16.64 / 229.86 3 47
8 13 1039.9 13287 80 15.21 985 1199 17.84 / 231.06 3 48
9 13 1000.7 13293 80 15.16 966 1172 19.01 / 232.23 3 51
10 13 732.7 13322 80 15.16 796 965 19.98 / 233.20 3 60
11 14 1.1 13400 86 15.21 318 416 20.40 / 233.62 3 103
12 14 1.4 13401 14 15.20 327 70 20.46 / 233.68 3 81
Average= 13.75
(KJ/cycle)

Cycle 15 GMT 2/ 6/2024 19:29: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.9 8 85 15.21 338 437 0.44 / 193.17 3 6
2 6 5855.7 788 69 14.71 3796 3853 4.29 / 197.02 3 33
3 7 5344.0 12363 80 14.95 3525 4216 8.51 / 201.24 3 40
4 13 4387.7 12585 80 14.91 2973 3546 12.05 / 204.79 3 42
5 13 3114.6 12855 80 15.00 2241 2689 14.74 / 207.48 3 45
6 13 1979.4 13083 80 15.12 1571 1900 16.64 / 209.38 3 48
7 13 1129.8 13233 80 15.20 1042 1267 17.91 / 210.64 3 49
8 13 960.9 13257 80 15.18 939 1140 19.05 / 211.78 3 51
9 13 712.0 13283 80 15.17 782 949 20.00 / 212.73 3 61
10 14 1.6 13359 82 15.22 320 399 20.40 / 213.13 3 106
11 14 2.0 13359 18 15.20 321 88 20.49 / 213.22 4 87
Average= 13.33
(KJ/cycle)

Cycle 14 GMT 23/ 5/2024 17:25: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 8 89 15.21 349 472 0.47 / 173.12 3 6
2 6 5808.0 776 62 14.73 3778 3450 3.92 / 176.57 3 35
3 3 5322.4 0 1 15.03 3540 53 3.98 / 176.63 3 32
4 7 5344.7 3243 80 14.94 3563 4258 8.23 / 180.89 3 40
5 13 4402.5 3471 80 14.90 3005 3582 11.82 / 184.47 3 43
6 13 3045.4 3777 80 15.02 2202 2646 14.46 / 187.11 3 45
7 13 1993.9 3993 80 15.12 1575 1905 16.37 / 189.02 3 48
8 13 1103.1 4149 80 15.22 1022 1244 17.61 / 190.26 3 48
9 13 841.5 4185 80 15.21 857 1043 18.65 / 191.31 3 47
10 13 732.0 4197 80 15.17 790 959 19.61 / 192.26 3 60
11 14 0.5 4275 101 15.22 306 470 20.08 / 192.74 3 101
Average= 12.85
(KJ/cycle)

Cycle 13 GMT 19/ 5/2024 23: 3: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.6 8 89 15.22 347 470 0.47 / 153.13 3 6
2 6 5796.6 791 62 14.73 3787 3459 3.93 / 156.59 3 35
3 7 5315.5 3243 80 14.96 3524 4218 8.15 / 160.80 3 41
4 13 4356.6 3471 80 14.91 2969 3541 11.69 / 164.35 3 41
5 13 3040.3 3753 80 15.02 2201 2645 14.33 / 166.99 3 44
6 13 1992.9 3963 80 15.13 1563 1892 16.22 / 168.88 3 47
7 13 1043.5 4131 80 15.23 986 1201 17.43 / 170.08 3 50
8 13 962.2 4143 80 15.19 930 1130 18.56 / 171.21 3 49
9 13 716.3 4169 80 15.18 781 948 19.50 / 172.16 3 59
10 14 1.1 4246 102 15.23 315 489 19.99 / 172.65 3 101
Average= 12.33
(KJ/cycle)

Cycle 12 GMT 16/ 5/2024 4:52: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.6 8 89 15.22 346 469 0.47 / 133.14 3 6
2 6 5809.3 793 62 14.74 3782 3456 3.92 / 136.60 3 34
3 7 5338.9 3243 80 14.97 3552 4254 8.18 / 140.85 3 40
4 13 4384.6 3471 80 14.92 2993 3572 11.75 / 144.42 3 44
5 13 2978.8 3795 80 15.04 2179 2622 14.37 / 147.05 3 46
6 13 1991.5 3993 80 15.13 1570 1900 16.27 / 148.95 3 47
7 13 991.8 4167 80 15.25 950 1159 17.43 / 150.11 3 49
8 13 949.2 4173 80 15.20 924 1124 18.56 / 151.23 3 49
9 13 729.2 4197 80 15.19 782 950 19.51 / 152.18 3 61
10 14 1.1 4272 86 15.23 314 411 19.92 / 152.59 3 100
11 14 1.3 4272 14 15.22 313 67 19.98 / 152.66 4 86
Average= 11.74
(KJ/cycle)

Cycle 11 GMT 12/ 5/2024 10:13: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 8 101 15.24 343 528 0.53 / 113.77 3 7
2 6 5507.6 748 61 14.78 3630 3273 3.80 / 117.05 3 36
3 3 5034.8 0 2 15.08 3414 103 3.90 / 117.15 3 33
4 7 5030.1 1803 80 14.99 3401 4078 7.98 / 121.23 3 40
5 13 4114.3 2019 80 14.94 2851 3408 11.39 / 124.63 3 44
6 13 2784.3 2307 80 15.07 2053 2475 13.86 / 127.11 3 44
7 13 1910.4 2463 80 15.14 1520 1841 15.71 / 128.95 3 48
8 13 995.8 2607 80 15.24 958 1168 16.87 / 130.12 3 49
9 13 953.5 2613 80 15.19 928 1128 18.00 / 131.25 3 51
10 13 726.0 2636 80 15.18 782 950 18.95 / 132.20 3 154
11 14 0.8 2710 69 15.23 315 331 19.28 / 132.53 3 103
12 14 0.9 2710 31 15.22 311 147 19.43 / 132.67 9 123
Average= 11.06
(KJ/cycle)

Cycle 10 GMT 9/ 5/2024 18:24: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.2 8 102 15.24 356 553 0.55 / 95.38 3 6
2 6 5508.1 773 61 14.79 3650 3293 3.85 / 98.67 3 35
3 7 4998.1 1803 80 15.00 3369 4043 7.89 / 102.72 3 40
4 13 3991.0 2049 80 14.97 2761 3307 11.20 / 106.02 3 44
5 13 2788.5 2307 80 15.07 2045 2465 13.66 / 108.49 3 43
6 13 1988.0 2451 80 15.13 1564 1893 15.55 / 110.38 3 47
7 13 969.9 2607 80 15.25 934 1139 16.69 / 111.52 3 50
8 13 737.4 2637 80 15.24 789 962 17.66 / 112.48 3 46
9 14 0.4 2727 162 15.26 308 761 18.42 / 113.24 3 104
Average= 10.29
(KJ/cycle)

Cycle 9 GMT 7/ 5/2024 1:51: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.4 9 126 15.24 351 674 0.67 / 78.84 3 7
2 6 5007.0 712 61 14.84 3373 3053 3.73 / 81.89 3 37
3 7 4479.1 722 80 15.04 3073 3697 7.42 / 85.59 3 41
4 13 3602.6 926 80 15.01 2533 3042 10.47 / 88.63 3 44
5 13 2278.1 1214 80 15.14 1754 2124 12.59 / 90.75 3 46
6 13 1428.5 1370 80 15.22 1229 1496 14.09 / 92.25 3 50
7 13 972.8 1436 80 15.24 938 1144 15.23 / 93.39 3 50
8 13 742.5 1463 80 15.22 787 958 16.19 / 94.35 3 48
9 14 0.5 1544 100 15.26 312 476 16.67 / 94.83 3 102
Average= 9.48
(KJ/cycle)

Cycle 8 GMT 5/ 5/2024 0: 2: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.0 9 123 15.26 350 657 0.66 / 61.88 3 8
2 6 5007.5 683 60 14.85 3399 3029 3.69 / 64.91 3 35
3 3 4573.1 1044 4 15.12 3122 189 3.87 / 65.10 3 38
4 7 4533.3 722 80 15.03 3094 3720 7.59 / 68.82 3 40
5 13 3572.7 938 80 15.02 2523 3032 10.63 / 71.85 3 45
6 13 2258.7 1244 80 15.15 1745 2115 12.74 / 73.96 3 44
7 13 1589.9 1364 80 15.19 1323 1608 14.35 / 75.57 3 50
8 13 978.2 1454 80 15.24 945 1152 15.50 / 76.72 3 50
9 13 733.8 1483 80 15.23 789 961 16.46 / 77.68 3 47
10 14 0.7 1563 86 15.27 314 412 16.87 / 78.10 3 102
11 14 1.2 1564 14 15.25 312 67 16.94 / 78.16 5 79
Average= 8.68
(KJ/cycle)

Cycle 7 GMT 2/ 5/2024 22:21: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.6 9 165 15.24 348 875 0.88 / 48.55 3 10
2 6 4009.0 570 62 14.96 2769 2568 3.44 / 51.12 3 38
3 3 3634.0 0 7 15.18 2549 271 3.71 / 51.39 3 39
4 7 3532.4 843 80 15.14 2513 3044 6.76 / 54.43 3 43
5 13 2606.9 1059 80 15.14 1949 2361 9.12 / 56.79 3 44
6 13 1728.1 1221 80 15.19 1420 1726 10.84 / 58.52 3 48
7 13 1000.7 1335 80 15.26 971 1185 12.03 / 59.70 3 49
8 13 741.1 1368 80 15.25 804 981 13.01 / 60.68 3 45
9 14 0.6 1454 114 15.28 309 538 13.55 / 61.22 3 101
Average= 7.65
(KJ/cycle)

Cycle 6 GMT 1/ 5/2024 6:23: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.2 9 137 15.38 348 733 0.73 / 33.93 3 9
2 6 4010.9 510 62 14.98 2790 2591 3.32 / 36.52 3 37
3 3 4148.8 751 36 15.05 2874 1557 4.88 / 38.07 3 39
4 3 3608.0 992 5 15.21 2545 194 5.08 / 38.27 3 41
5 7 3496.1 482 80 15.15 2475 3000 8.07 / 41.27 3 43
6 13 2491.4 728 80 15.16 1882 2282 10.36 / 43.55 3 44
7 13 1807.6 854 80 15.18 1490 1809 12.17 / 45.36 3 48
8 13 1001.9 977 80 15.25 974 1188 13.36 / 46.55 3 48
9 13 99.3 1098 80 15.28 376 460 13.81 / 47.01 3 23
10 14 0.4 1119 142 15.27 307 666 14.48 / 47.67 3 100
Average= 6.81
(KJ/cycle)

Cycle 5 GMT 29/ 4/2024 15: 1: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.0 12 311 15.35 352 1680 1.68 / 29.44 3 9
2 6 1010.2 176 73 15.28 951 1061 2.74 / 30.51 3 22
3 3 677.6 417 3 15.47 800 37 2.78 / 30.54 3 24
4 7 577.6 1140 80 15.56 675 840 3.62 / 31.38 3 27
5 13 547.8 1146 80 15.51 661 820 4.44 / 32.20 3 28
6 13 41.7 1211 80 15.44 330 408 4.85 / 32.61 3 21
7 14 0.4 1223 127 15.42 297 582 5.43 / 33.19 3 109
Average= 5.53
(KJ/cycle)

Cycle 4 GMT 28/ 4/2024 18:30: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.0 12 311 15.35 356 1699 1.70 / 24.06 3 9
2 6 1017.0 180 74 15.27 957 1081 2.78 / 25.15 3 23
3 7 583.1 1144 80 15.56 681 848 3.63 / 25.99 3 26
4 13 551.5 1150 80 15.51 654 811 4.44 / 26.80 3 27
5 14 0.1 1229 208 15.43 299 960 5.40 / 27.76 3 110
Average= 5.55
(KJ/cycle)

Cycle 3 GMT 27/ 4/2024 21:52: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.5 12 311 15.37 351 1678 1.68 / 18.62 3 9
2 6 1017.2 180 74 15.28 953 1078 2.76 / 19.70 3 24
3 3 638.9 421 1 15.48 763 12 2.77 / 19.71 3 24
4 7 583.2 1144 80 15.56 687 855 3.62 / 20.57 3 27
5 13 553.1 1150 80 15.51 665 825 4.45 / 21.39 3 27
6 13 51.5 1216 80 15.44 333 411 4.86 / 21.81 3 22
7 14 0.5 1229 120 15.42 302 559 5.42 / 22.36 3 105
Average= 5.59
(KJ/cycle)

Cycle 2 GMT 27/ 4/2024 1:14: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.0 12 309 15.37 361 1715 1.71 / 13.30 3 9
2 6 1010.5 172 73 15.28 958 1069 2.78 / 14.37 3 23
3 3 787.5 293 9 15.40 845 117 2.90 / 14.48 3 27
4 7 486.2 1016 80 15.57 619 771 3.67 / 15.25 3 24
5 13 455.1 1022 80 15.52 600 745 4.42 / 16.00 3 23
6 14 0.5 1089 204 15.44 301 948 5.36 / 16.95 3 110
Average= 5.65
(KJ/cycle)

Cycle 1 GMT 26/ 4/2024 6:53: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.1 11 275 15.27 365 1533 1.53 / 7.22 3 9
2 6 1013.8 144 73 15.28 970 1082 2.61 / 8.30 3 19
3 3 1264.7 266 34 15.36 1141 596 3.21 / 8.90 3 30
4 3 952.2 387 17 15.43 963 253 3.46 / 9.15 3 35
5 3 658.4 507 2 15.51 852 26 3.49 / 9.18 3 27
6 7 424.0 990 80 15.57 589 734 4.22 / 9.91 3 22
7 13 394.4 996 80 15.52 571 709 4.93 / 10.62 3 21
8 14 0.1 1055 200 15.45 312 964 5.90 / 11.58 3 107
Average= 5.79
(KJ/cycle)

Cycle 0 GMT 25/ 4/2024 13: 9: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 106.6 9819 397 15.52 397 2446 2.45 / 2.45 3 14
2 7 188.8 9821 80 15.44 424 524 2.97 / 2.97 3 9
3 13 239.4 9827 80 15.40 457 563 3.53 / 3.53 3 9
4 13 322.8 9845 80 15.35 512 629 4.16 / 4.16 3 41
5 13 284.2 9863 80 15.31 494 605 4.77 / 4.77 3 83
6 13 118.4 9887 80 15.31 381 467 5.23 / 5.23 3 166
7 14 1.0 9906 16 15.31 322 79 5.31 / 5.31 3 112
8 14 1.1 9907 84 15.30 291 374 5.69 / 5.69 21 247
Average= 5.69
(KJ/cycle)