SIO Argo Site:
Pump Diagnostics Page   



Serial= 6113 WMO= 1902365

Return

←PreviousNext→

Cycle 35 GMT 18/12/2024 6:43: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.9 8 110 15.06 408 676 0.68 / 672.21 2 10
2 6 5952.3 778 62 14.56 4146 3743 4.42 / 675.96 2 35
3 7 5545.9 12002 80 14.78 3872 4578 9.00 / 680.53 2 39
4 13 4565.6 12230 80 14.69 3260 3831 12.83 / 684.36 2 42
5 13 3268.0 12506 80 14.81 2496 2957 15.79 / 687.32 2 42
6 13 1987.8 12776 80 14.97 1711 2049 17.83 / 689.37 2 42
7 13 1246.7 12902 80 15.04 1241 1493 19.33 / 690.86 2 44
8 13 981.4 12938 80 15.03 1063 1278 20.61 / 692.14 2 43
9 13 738.0 12965 80 15.01 905 1087 21.69 / 693.23 2 40
10 14 1.5 13043 116 15.08 372 651 22.34 / 693.88 2 148
Average= 19.27
(KJ/cycle)

Cycle 34 GMT 8/12/2024 8: 5: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.6 8 110 15.07 404 670 0.67 / 649.69 2 9
2 6 5951.2 766 62 14.56 4118 3717 4.39 / 653.41 2 38
3 7 5557.3 12002 80 14.79 3878 4588 8.98 / 657.99 2 40
4 13 4560.2 12236 80 14.69 3292 3869 12.84 / 661.86 2 42
5 13 3236.4 12530 80 14.81 2487 2947 15.79 / 664.81 2 44
6 13 2192.0 12740 80 14.92 1844 2201 17.99 / 667.01 2 44
7 13 1213.4 12908 80 15.04 1226 1475 19.47 / 668.49 2 46
8 13 991.7 12938 80 15.02 1079 1297 20.76 / 669.78 2 43
9 13 739.3 12965 80 15.01 917 1101 21.86 / 670.88 2 41
10 14 1.2 13042 114 15.08 380 653 22.52 / 671.54 2 107
Average= 19.19
(KJ/cycle)

Cycle 33 GMT 28/11/2024 9:41: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.6 8 110 15.07 405 671 0.67 / 627.39 2 8
2 6 5951.3 768 62 14.57 4098 3702 4.37 / 631.09 2 39
3 7 5550.0 12002 80 14.79 3858 4565 8.94 / 635.66 2 41
4 13 4607.1 12224 80 14.68 3321 3900 12.84 / 639.56 2 42
5 13 3315.7 12494 80 14.80 2546 3014 15.85 / 642.57 2 45
6 13 1998.7 12770 80 14.97 1721 2061 17.91 / 644.63 2 43
7 13 1182.5 12914 80 15.05 1204 1450 19.36 / 646.08 2 43
8 13 882.1 12956 80 15.05 1002 1206 20.57 / 647.29 2 42
9 13 727.5 12973 80 15.02 900 1081 21.65 / 648.37 2 39
10 14 1.1 13051 116 15.09 370 648 22.30 / 649.02 2 154
Average= 19.09
(KJ/cycle)

Cycle 32 GMT 18/11/2024 11: 7: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.0 8 111 15.07 398 666 0.67 / 605.20 2 7
2 6 5948.9 779 62 14.57 4132 3733 4.40 / 608.93 2 35
3 7 5522.0 12002 80 14.80 3855 4564 8.96 / 613.50 2 40
4 13 4613.2 12218 80 14.67 3340 3920 12.88 / 617.42 2 42
5 13 3172.3 12524 80 14.83 2460 2919 15.80 / 620.34 2 44
6 13 1992.0 12770 80 14.97 1708 2046 17.85 / 622.38 2 42
7 13 1090.8 12926 80 15.07 1136 1370 19.22 / 623.75 2 42
8 13 827.4 12962 80 15.06 961 1158 20.37 / 624.91 2 40
9 13 731.1 12973 80 15.02 894 1074 21.45 / 625.98 2 39
10 14 1.3 13050 131 15.09 372 735 22.18 / 626.72 2 124
Average= 18.99
(KJ/cycle)

Cycle 31 GMT 8/11/2024 12:24: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.5 8 110 15.07 401 665 0.66 / 582.53 2 7
2 6 5944.2 795 62 14.58 4108 3713 4.38 / 586.24 2 35
3 7 5550.5 12002 80 14.81 3844 4554 8.93 / 590.79 2 39
4 13 4647.2 12218 80 14.68 3335 3917 12.85 / 594.71 2 43
5 13 3309.9 12500 80 14.81 2537 3006 15.86 / 597.72 2 46
6 13 2185.8 12716 80 14.93 1841 2199 18.05 / 599.92 2 45
7 13 1267.5 12878 80 15.04 1251 1505 19.56 / 601.42 2 43
8 13 995.3 12914 80 15.03 1067 1283 20.84 / 602.70 2 42
9 13 731.7 12944 80 15.02 898 1079 21.92 / 603.78 2 38
10 14 0.8 13025 138 15.09 362 754 22.67 / 604.54 2 149
Average= 18.89
(KJ/cycle)

Cycle 30 GMT 29/10/2024 13:47: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.1 8 111 15.07 402 672 0.67 / 560.04 2 6
2 6 5942.8 774 62 14.57 4149 3748 4.42 / 563.78 2 35
3 7 5522.5 12002 80 14.81 3841 4551 8.97 / 568.33 2 39
4 13 4590.1 12212 80 14.69 3286 3862 12.83 / 572.20 2 41
5 13 3285.7 12494 80 14.82 2517 2984 15.82 / 575.18 2 45
6 13 2049.7 12752 80 14.96 1754 2099 17.92 / 577.28 2 44
7 13 1265.5 12884 80 15.04 1254 1509 19.43 / 578.79 2 42
8 13 914.6 12932 80 15.05 1020 1228 20.65 / 580.02 2 41
9 13 729.6 12953 80 15.02 906 1089 21.74 / 581.11 2 37
10 14 1.1 13031 135 15.09 371 756 22.50 / 581.86 2 130
Average= 18.77
(KJ/cycle)

Cycle 29 GMT 19/10/2024 15:28: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.4 8 111 15.08 399 668 0.67 / 537.34 2 6
2 6 5946.5 771 62 14.58 4127 3731 4.40 / 541.07 2 38
3 7 5557.9 12002 80 14.80 3902 4620 9.02 / 545.69 2 40
4 13 4624.1 12218 80 14.69 3338 3923 12.94 / 549.61 2 42
5 13 3363.7 12482 80 14.81 2576 3052 15.99 / 552.66 2 45
6 13 1989.7 12764 80 14.98 1730 2073 18.07 / 554.74 2 43
7 13 1213.2 12896 80 15.06 1227 1478 19.54 / 556.22 2 42
8 13 996.3 12926 80 15.03 1083 1302 20.85 / 557.52 2 42
9 13 733.1 12955 80 15.03 908 1092 21.94 / 558.61 2 37
10 14 1.5 13034 135 15.09 370 754 22.69 / 559.36 2 163
Average= 18.65
(KJ/cycle)

Cycle 28 GMT 9/10/2024 17:10: 2

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.3 8 111 15.09 397 665 0.66 / 514.68 2 6
2 6 5947.0 776 62 14.57 4150 3749 4.41 / 518.43 2 36
3 7 5551.9 12002 80 14.82 3848 4562 8.98 / 522.99 2 41
4 13 4599.5 12230 80 14.71 3292 3874 12.85 / 526.86 2 40
5 13 3346.8 12488 80 14.82 2560 3035 15.89 / 529.90 2 45
6 13 2053.9 12758 80 14.97 1762 2110 18.00 / 532.01 2 44
7 13 1322.7 12884 80 15.04 1293 1556 19.55 / 533.56 2 41
8 13 926.3 12938 80 15.06 1031 1242 20.79 / 534.81 2 42
9 13 739.1 12959 80 15.03 913 1098 21.89 / 535.90 2 39
10 14 0.9 13040 138 15.10 368 767 22.66 / 536.67 2 177
Average= 18.51
(KJ/cycle)

Cycle 27 GMT 29/ 9/2024 18:38:59

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.6 8 111 15.09 397 665 0.66 / 492.27 2 6
2 6 5944.9 784 62 14.59 4100 3709 4.37 / 495.98 2 36
3 7 5547.9 12002 80 14.82 3870 4588 8.96 / 500.57 2 41
4 13 4516.7 12242 80 14.73 3254 3835 12.80 / 504.40 2 42
5 13 3304.0 12500 80 14.83 2532 3004 15.80 / 507.41 2 43
6 13 1999.7 12770 80 14.99 1729 2073 17.87 / 509.48 2 44
7 13 1228.6 12902 80 15.06 1223 1473 19.35 / 510.95 2 44
8 13 916.1 12944 80 15.06 1030 1241 20.59 / 512.19 2 43
9 13 724.4 12965 80 15.04 893 1074 21.66 / 513.27 2 38
10 14 1.3 13043 135 15.10 365 744 22.41 / 514.01 2 157
Average= 18.36
(KJ/cycle)

Cycle 26 GMT 19/ 9/2024 20: 0: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.2 8 111 15.10 406 680 0.68 / 469.89 2 6
2 6 5817.3 750 61 14.61 4045 3605 4.29 / 473.49 2 37
3 7 5560.7 12002 80 14.83 3854 4572 8.86 / 478.07 2 39
4 13 4582.9 12224 80 14.74 3279 3867 12.72 / 481.93 2 42
5 13 3331.1 12488 80 14.84 2548 3025 15.75 / 484.96 2 44
6 13 2003.9 12764 80 15.00 1715 2058 17.81 / 487.01 2 43
7 13 1235.7 12896 80 15.07 1234 1488 19.30 / 488.50 2 44
8 13 970.6 12932 80 15.06 1060 1277 20.57 / 489.78 2 43
9 13 724.2 12959 80 15.04 896 1078 21.65 / 490.86 2 37
10 14 1.3 13037 135 15.11 367 749 22.40 / 491.61 2 179
Average= 18.21
(KJ/cycle)

Cycle 25 GMT 9/ 9/2024 22: 0: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.8 8 111 15.11 403 676 0.68 / 447.57 2 7
2 6 5929.1 768 62 14.60 4093 3705 4.38 / 451.27 2 37
3 7 5543.5 12002 80 14.82 3897 4620 9.00 / 455.89 2 41
4 13 4527.4 12248 80 14.75 3273 3862 12.86 / 459.75 2 44
5 13 3213.6 12536 80 14.87 2466 2934 15.80 / 462.69 2 44
6 13 2000.3 12782 80 15.00 1732 2078 17.88 / 464.77 2 43
7 13 1134.9 12932 80 15.09 1172 1415 19.29 / 466.18 2 42
8 13 877.1 12968 80 15.08 1003 1210 20.50 / 467.39 2 42
9 13 741.9 12983 80 15.04 914 1100 21.60 / 468.49 2 37
10 14 1.4 13061 129 15.11 368 717 22.32 / 469.21 2 177
Average= 18.05
(KJ/cycle)

Cycle 24 GMT 30/ 8/2024 23:16: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.0 8 111 15.11 404 678 0.68 / 425.30 2 7
2 6 5931.0 772 62 14.61 4084 3699 4.38 / 429.00 2 35
3 7 5543.6 12002 80 14.82 3878 4598 8.97 / 433.60 2 41
4 13 4545.8 12236 80 14.76 3294 3890 12.86 / 437.49 2 44
5 13 3249.9 12500 80 14.87 2489 2961 15.83 / 440.45 2 44
6 13 1999.9 12764 80 15.01 1721 2067 17.89 / 442.51 2 44
7 13 1113.0 12920 80 15.10 1155 1395 19.29 / 443.91 2 42
8 13 853.9 12956 80 15.09 991 1196 20.48 / 445.11 2 41
9 13 722.7 12971 80 15.06 898 1082 21.57 / 446.19 2 38
10 14 1.3 13048 127 15.12 366 703 22.27 / 446.89 2 170
Average= 17.88
(KJ/cycle)

Cycle 23 GMT 21/ 8/2024 0:36: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.1 8 111 15.11 402 674 0.67 / 402.76 2 7
2 6 5878.8 761 61 14.62 4062 3623 4.30 / 406.38 2 36
3 7 5565.5 12002 80 14.82 3929 4658 8.96 / 411.04 2 39
4 13 4617.9 12230 80 14.75 3325 3923 12.88 / 414.96 2 41
5 13 3348.1 12482 80 14.86 2575 3061 15.94 / 418.02 2 45
6 13 2011.2 12758 80 15.01 1740 2089 18.03 / 420.11 2 42
7 13 1074.3 12920 80 15.12 1144 1384 19.41 / 421.50 2 41
8 13 993.3 12932 80 15.07 1086 1309 20.72 / 422.81 2 42
9 13 741.1 12959 80 15.06 916 1104 21.83 / 423.91 2 37
10 14 1.7 13037 127 15.12 371 712 22.54 / 424.62 2 106
Average= 17.69
(KJ/cycle)

Cycle 22 GMT 11/ 8/2024 2:19: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 8 111 15.12 408 685 0.68 / 380.26 2 7
2 6 5943.5 784 62 14.62 4119 3734 4.42 / 383.99 2 39
3 7 5539.4 12002 80 14.84 3857 4579 9.00 / 388.57 2 39
4 13 4527.6 12242 80 14.77 3311 3912 12.91 / 392.48 2 44
5 13 3254.4 12518 80 14.88 2505 2982 15.89 / 395.47 2 44
6 13 1990.8 12788 80 15.02 1724 2072 17.96 / 397.54 2 42
7 13 1167.3 12932 80 15.11 1197 1447 19.41 / 398.99 2 41
8 13 949.3 12962 80 15.08 1059 1278 20.69 / 400.26 2 43
9 13 732.4 12985 80 15.07 913 1101 21.79 / 401.36 2 38
10 14 1.6 13063 127 15.13 375 721 22.51 / 402.08 2 174
Average= 17.48
(KJ/cycle)

Cycle 21 GMT 1/ 8/2024 3:15: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.5 8 111 15.13 408 685 0.69 / 357.62 2 6
2 6 5945.3 780 61 14.64 4074 3638 4.32 / 361.25 2 36
3 3 5521.2 1021 1 14.96 3858 58 4.38 / 361.31 2 36
4 7 5546.5 12002 80 14.84 3872 4597 8.98 / 365.91 2 39
5 13 4514.4 12248 80 14.79 3277 3877 12.86 / 369.79 2 42
6 13 3362.6 12494 80 14.87 2570 3057 15.91 / 372.84 2 44
7 13 1998.3 12776 80 15.03 1732 2083 18.00 / 374.93 2 45
8 13 1225.7 12908 80 15.10 1241 1499 19.49 / 376.43 2 43
9 13 994.9 12938 80 15.08 1089 1314 20.81 / 377.74 2 42
10 13 743.7 12965 80 15.07 927 1118 21.93 / 378.86 2 40
11 14 1.8 13043 127 15.13 374 719 22.64 / 379.58 2 153
Average= 17.25
(KJ/cycle)

Cycle 20 GMT 22/ 7/2024 4:36: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.1 8 111 15.13 414 695 0.70 / 335.13 2 7
2 6 5907.6 776 62 14.63 4082 3703 4.40 / 338.83 2 38
3 7 5541.2 12002 80 14.84 3877 4603 9.00 / 343.44 2 40
4 13 4590.7 12224 80 14.78 3359 3972 12.97 / 347.41 2 43
5 13 3249.6 12506 80 14.90 2514 2997 15.97 / 350.41 2 44
6 13 1998.3 12758 80 15.04 1722 2072 18.04 / 352.48 2 42
7 13 1165.7 12902 80 15.12 1203 1455 19.50 / 353.93 2 42
8 13 859.7 12944 80 15.12 1000 1210 20.71 / 355.14 2 42
9 13 722.3 12959 80 15.08 907 1094 21.80 / 356.24 2 36
10 14 1.0 13037 123 15.14 373 695 22.49 / 356.93 2 113
Average= 17.00
(KJ/cycle)

Cycle 19 GMT 12/ 7/2024 6: 8: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 8 111 15.14 412 692 0.69 / 312.60 2 7
2 6 5781.8 738 62 14.64 4031 3659 4.35 / 316.26 2 35
3 7 5544.7 12002 80 14.85 3866 4593 8.94 / 320.86 2 40
4 13 4614.2 12212 80 14.78 3388 4006 12.95 / 324.86 2 43
5 13 3214.6 12506 80 14.91 2499 2981 15.93 / 327.84 2 43
6 13 1983.1 12764 80 15.04 1733 2085 18.02 / 329.93 2 45
7 13 1174.6 12902 80 15.12 1213 1467 19.48 / 331.40 2 43
8 13 868.0 12944 80 15.12 1014 1227 20.71 / 332.62 2 39
9 13 731.8 12959 80 15.08 920 1110 21.82 / 333.73 2 37
10 14 1.6 13036 123 15.15 378 704 22.52 / 334.44 2 112
Average= 16.72
(KJ/cycle)

Cycle 18 GMT 2/ 7/2024 8:18: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.1 8 111 15.14 408 686 0.69 / 290.27 2 8
2 6 5592.6 692 68 14.66 3906 3894 4.58 / 294.16 2 38
3 7 5436.6 12002 80 14.86 3797 4514 9.09 / 298.68 2 39
4 13 4478.5 12224 80 14.82 3237 3838 12.93 / 302.52 2 42
5 13 3086.7 12530 80 14.94 2407 2877 15.81 / 305.39 2 44
6 13 1988.7 12758 80 15.05 1741 2096 17.90 / 307.49 2 43
7 13 1080.9 12914 80 15.14 1156 1400 19.30 / 308.89 2 41
8 13 908.8 12938 80 15.12 1044 1263 20.57 / 310.15 2 41
9 13 712.8 12959 80 15.09 908 1096 21.66 / 311.25 2 38
10 14 1.4 13033 114 15.16 384 664 22.33 / 311.91 2 109
Average= 16.42
(KJ/cycle)

Cycle 17 GMT 22/ 6/2024 11:19: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.5 8 111 15.15 409 688 0.69 / 267.73 2 9
2 6 5666.0 716 64 14.67 3974 3731 4.42 / 271.46 2 36
3 7 5503.1 12002 80 14.86 3858 4586 9.01 / 276.05 2 40
4 13 4483.3 12242 80 14.82 3301 3914 12.92 / 279.96 2 42
5 13 3312.1 12488 80 14.90 2548 3037 15.96 / 283.00 2 44
6 13 1997.4 12752 80 15.05 1747 2103 18.06 / 285.10 2 44
7 13 1105.7 12908 80 15.14 1182 1432 19.49 / 286.53 2 41
8 13 887.5 12938 80 15.13 1038 1256 20.75 / 287.79 2 42
9 13 729.5 12955 80 15.09 922 1113 21.86 / 288.90 2 37
10 14 1.1 13032 120 15.16 375 682 22.54 / 289.59 2 123
Average= 16.09
(KJ/cycle)

Cycle 16 GMT 12/ 6/2024 13:57: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 8 110 15.16 411 685 0.69 / 245.09 2 8
2 6 5847.9 751 62 14.66 4051 3682 4.37 / 248.77 2 36
3 3 5517.6 0 1 14.95 3851 58 4.42 / 248.83 2 36
4 7 5556.7 12363 80 14.86 3886 4620 9.04 / 253.45 2 40
5 13 4580.8 12585 80 14.81 3364 3986 13.03 / 257.43 2 43
6 13 3181.1 12891 80 14.94 2471 2953 15.98 / 260.39 2 47
7 13 1982.1 13137 80 15.06 1730 2084 18.07 / 262.47 2 45
8 13 1154.1 13281 80 15.14 1208 1463 19.53 / 263.93 2 41
9 13 932.0 13311 80 15.12 1059 1281 20.81 / 265.21 2 42
10 13 738.4 13332 80 15.10 930 1123 21.94 / 266.34 2 36
11 14 1.2 13410 123 15.16 378 705 22.64 / 267.04 2 127
Average= 15.71
(KJ/cycle)

Cycle 15 GMT 2/ 6/2024 11:41: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.0 8 110 15.17 404 674 0.67 / 222.44 2 9
2 6 5925.2 775 62 14.66 4111 3737 4.41 / 226.18 2 35
3 7 5559.6 12363 80 14.87 3867 4600 9.01 / 230.78 2 40
4 13 4697.3 12561 80 14.79 3451 4083 13.09 / 234.86 2 41
5 13 3224.0 12873 80 14.94 2515 3006 16.10 / 237.86 2 43
6 13 1991.3 13119 80 15.07 1746 2105 18.21 / 239.97 2 42
7 13 1159.0 13263 80 15.15 1211 1468 19.67 / 241.44 2 43
8 13 806.5 13311 80 15.16 979 1187 20.86 / 242.62 2 40
9 13 725.3 13320 80 15.11 917 1108 21.97 / 243.73 2 38
10 14 1.7 13397 116 15.17 380 669 22.64 / 244.40 2 134
Average= 15.28
(KJ/cycle)

Cycle 14 GMT 23/ 5/2024 9:16: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.1 8 110 15.19 394 658 0.66 / 200.00 2 9
2 6 5908.5 771 62 14.67 4094 3724 4.38 / 203.73 2 36
3 7 5536.4 3243 80 14.87 3891 4629 9.01 / 208.35 2 40
4 13 4532.5 3489 80 14.83 3343 3966 12.98 / 212.32 2 42
5 13 3203.6 3759 80 14.95 2471 2955 15.93 / 215.28 2 43
6 13 1986.2 4005 80 15.08 1721 2076 18.01 / 217.35 2 41
7 13 1110.7 4155 80 15.17 1164 1413 19.42 / 218.76 2 41
8 13 895.4 4185 80 15.15 1028 1246 20.67 / 220.01 2 43
9 13 728.4 4202 80 15.12 909 1100 21.77 / 221.11 2 38
10 14 1.5 4279 116 15.18 372 655 22.42 / 221.76 2 160
Average= 14.78
(KJ/cycle)

Cycle 13 GMT 19/ 5/2024 14:49: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.6 8 110 15.18 406 678 0.68 / 178.30 2 7
2 6 5914.0 777 62 14.66 4140 3763 4.44 / 182.06 2 36
3 7 5531.3 3243 80 14.88 3877 4615 9.06 / 186.68 2 40
4 13 4490.0 3483 80 14.84 3312 3932 12.99 / 190.61 2 42
5 13 3250.9 3753 80 14.95 2498 2988 15.98 / 193.60 2 42
6 13 1993.0 3999 80 15.09 1726 2084 18.06 / 195.68 2 41
7 13 1244.8 4125 80 15.15 1249 1514 19.57 / 197.19 2 42
8 13 743.7 4191 80 15.18 923 1121 20.69 / 198.31 2 37
9 14 0.9 4283 185 15.21 366 1030 21.72 / 199.34 2 145
Average= 14.24
(KJ/cycle)

Cycle 12 GMT 15/ 5/2024 20:16: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.8 8 108 15.20 409 671 0.67 / 155.64 2 10
2 6 5938.3 774 63 14.68 4097 3789 4.46 / 159.43 2 36
3 3 5523.2 0 1 14.98 3906 59 4.52 / 159.49 2 35
4 7 5549.9 3243 80 14.90 3902 4651 9.17 / 164.14 2 39
5 13 4487.5 3501 80 14.85 3296 3916 13.09 / 168.06 2 43
6 13 3253.5 3765 80 14.95 2527 3022 16.11 / 171.08 2 44
7 13 1992.8 4023 80 15.10 1729 2089 18.20 / 173.17 2 40
8 13 1090.6 4179 80 15.19 1162 1412 19.61 / 174.58 2 43
9 13 964.3 4197 80 15.15 1067 1293 20.90 / 175.87 2 43
10 13 710.6 4224 80 15.14 895 1084 21.99 / 176.96 2 37
11 14 1.2 4299 116 15.20 376 663 22.65 / 177.62 2 171
Average= 13.66
(KJ/cycle)

Cycle 11 GMT 12/ 5/2024 1:30: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.8 9 132 15.20 402 807 0.81 / 135.63 2 11
2 6 5506.8 752 61 14.74 3871 3481 4.29 / 139.11 2 37
3 7 5016.4 1803 80 14.95 3624 4334 8.62 / 143.44 2 40
4 13 3966.2 2055 80 14.91 2977 3551 12.17 / 146.99 2 42
5 13 2716.6 2313 80 15.02 2191 2633 14.81 / 149.62 2 44
6 13 1904.1 2451 80 15.08 1674 2020 16.82 / 151.64 2 43
7 13 973.0 2589 80 15.20 1078 1311 18.14 / 152.95 2 42
8 13 738.0 2618 80 15.18 923 1121 19.26 / 154.08 2 35
9 14 0.9 2704 159 15.22 370 895 20.15 / 154.97 2 163
Average= 12.91
(KJ/cycle)

Cycle 10 GMT 9/ 5/2024 9:41: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.8 9 130 15.20 404 798 0.80 / 115.36 2 11
2 6 5508.7 738 62 14.73 3874 3538 4.34 / 118.90 2 36
3 7 5042.9 1803 80 14.94 3665 4380 8.72 / 123.28 2 40
4 13 4103.6 2007 80 14.90 3060 3648 12.36 / 126.93 2 44
5 13 2661.4 2319 80 15.05 2139 2575 14.94 / 129.50 2 42
6 13 1852.3 2463 80 15.11 1643 1986 16.93 / 131.49 2 42
7 13 984.1 2595 80 15.20 1087 1322 18.25 / 132.81 2 43
8 13 737.5 2625 80 15.18 923 1121 19.37 / 133.93 2 38
9 14 0.7 2711 159 15.23 367 889 20.26 / 134.82 2 143
Average= 12.26
(KJ/cycle)

Cycle 9 GMT 6/ 5/2024 18: 1: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.7 9 153 15.20 407 947 0.95 / 96.92 2 12
2 6 5007.6 688 61 14.78 3640 3282 4.23 / 100.20 2 38
3 7 4513.5 722 80 14.98 3324 3983 8.21 / 104.18 2 44
4 13 3545.8 944 80 14.97 2713 3249 11.46 / 107.43 2 44
5 13 2251.6 1214 80 15.10 1897 2292 13.75 / 109.72 2 43
6 13 1363.2 1370 80 15.18 1336 1622 15.37 / 111.35 2 43
7 13 980.0 1424 80 15.19 1083 1316 16.69 / 112.66 2 42
8 13 744.9 1451 80 15.17 925 1123 17.81 / 113.78 2 37
9 14 0.9 1532 138 15.22 370 777 18.59 / 114.56 2 147
Average= 11.46
(KJ/cycle)

Cycle 8 GMT 4/ 5/2024 16:46: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.4 9 149 15.21 410 929 0.93 / 78.17 2 10
2 6 5005.1 677 60 14.80 3593 3191 4.12 / 81.36 2 39
3 3 4604.7 1038 5 15.06 3439 259 4.38 / 81.62 2 39
4 7 4536.7 722 80 14.97 3384 4053 8.43 / 85.67 2 42
5 13 3480.0 968 80 14.97 2686 3217 11.65 / 88.89 2 43
6 13 2162.0 1256 80 15.12 1848 2235 13.88 / 91.12 2 42
7 13 1416.1 1388 80 15.17 1375 1669 15.55 / 92.79 2 42
8 13 978.7 1448 80 15.19 1085 1318 16.87 / 94.11 2 43
9 13 735.4 1475 80 15.17 925 1123 17.99 / 95.23 2 35
10 14 1.0 1554 129 15.23 375 737 18.73 / 95.97 2 118
Average= 10.66
(KJ/cycle)

Cycle 7 GMT 2/ 5/2024 15:21: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.7 10 189 15.07 410 1168 1.17 / 62.91 2 12
2 6 4010.6 561 63 14.87 3057 2864 4.03 / 65.78 2 40
3 3 3675.1 922 9 15.11 2817 383 4.41 / 66.16 2 41
4 7 3527.7 482 80 15.08 2718 3279 7.69 / 69.44 2 44
5 13 2545.0 710 80 15.09 2102 2538 10.23 / 71.98 2 44
6 13 1791.6 842 80 15.13 1612 1951 12.18 / 73.93 2 41
7 13 999.9 956 80 15.21 1111 1352 13.53 / 75.28 2 41
8 13 720.9 989 80 15.20 916 1114 14.65 / 76.40 2 40
9 14 0.5 1068 148 15.24 375 846 15.49 / 77.24 2 136
Average= 9.66
(KJ/cycle)

Cycle 6 GMT 30/ 4/2024 23:57: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.4 9 153 15.35 391 918 0.92 / 39.45 2 9
2 6 4012.9 487 62 14.94 3018 2796 3.71 / 42.25 2 37
3 3 4372.0 729 49 14.95 3236 2371 6.08 / 44.62 2 38
4 3 3637.2 970 7 15.14 2768 293 6.38 / 44.91 2 39
5 7 3443.8 482 80 15.10 2662 3216 9.59 / 48.13 2 41
6 13 2433.2 710 80 15.12 2023 2447 12.04 / 50.57 2 41
7 13 1567.8 866 80 15.18 1470 1785 13.83 / 52.36 2 41
8 13 999.3 950 80 15.22 1109 1350 15.18 / 53.71 2 40
9 13 961.0 954 80 15.15 1073 1300 16.48 / 55.01 2 40
10 13 943.8 956 80 15.07 1043 1257 17.73 / 56.27 2 39
11 13 923.8 958 80 15.02 996 1197 18.93 / 57.46 2 244
12 13 901.0 959 80 14.99 760 911 19.84 / 58.38 244 244
13 13 876.3 961 80 15.00 511 613 20.46 / 58.99 244 244
14 13 851.2 963 80 14.99 408 489 20.94 / 59.48 244 244
15 13 826.0 964 80 14.98 365 437 21.38 / 59.92 244 244
16 13 800.9 966 80 14.97 386 462 21.84 / 60.38 244 244
17 13 775.6 968 80 14.95 360 431 22.27 / 60.81 244 244
18 13 744.8 970 80 14.94 352 421 22.70 / 61.23 244 244
19 14 2.4 1027 1 15.11 356 5 22.70 / 61.24 244 244
20 14 2.4 1028 99 15.08 343 512 23.21 / 61.75 244 244
Average= 8.82
(KJ/cycle)

Cycle 5 GMT 29/ 4/2024 10:28: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.7 12 329 15.32 401 2021 2.02 / 34.21 2 10
2 6 1019.0 175 73 15.26 1048 1167 3.19 / 35.38 2 19
3 3 621.5 416 1 15.47 867 13 3.20 / 35.39 2 22
4 7 579.3 1139 80 15.54 777 966 4.17 / 36.36 2 23
5 13 548.0 1145 80 15.49 757 938 5.11 / 37.29 2 21
6 14 0.6 1220 228 15.41 353 1240 6.35 / 38.53 2 129
Average= 6.42
(KJ/cycle)

Cycle 4 GMT 28/ 4/2024 13:58: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.7 12 328 15.33 402 2021 2.02 / 27.82 2 7
2 6 1016.6 176 74 15.26 1049 1185 3.21 / 29.00 2 22
3 3 623.4 417 1 15.48 862 13 3.22 / 29.02 2 20
4 7 584.6 1140 80 15.54 778 967 4.19 / 29.98 2 20
5 13 550.4 1146 80 15.49 754 934 5.12 / 30.92 2 22
6 14 0.4 1224 228 15.40 362 1271 6.39 / 32.19 2 110
Average= 6.44
(KJ/cycle)

Cycle 3 GMT 27/ 4/2024 17:25: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.2 12 327 15.33 411 2060 2.06 / 21.56 2 6
2 6 1017.2 176 74 15.26 1050 1186 3.25 / 22.74 2 19
3 3 646.2 417 2 15.46 874 27 3.27 / 22.77 2 23
4 7 575.2 1140 80 15.55 778 968 4.24 / 23.74 2 20
5 13 545.2 1146 80 15.49 756 937 5.18 / 24.68 2 20
6 14 0.2 1224 202 15.41 360 1121 6.30 / 25.80 2 113
Average= 6.45
(KJ/cycle)

Cycle 2 GMT 26/ 4/2024 20:54: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.5 12 323 15.36 411 2039 2.04 / 15.29 2 13
2 6 1015.7 168 74 15.26 1037 1171 3.21 / 16.46 2 22
3 3 789.8 289 9 15.40 950 132 3.34 / 16.59 2 21
4 7 520.9 1013 80 15.55 735 914 4.26 / 17.50 2 18
5 13 487.3 1019 80 15.49 708 877 5.13 / 18.38 2 21
6 14 0.8 1086 200 15.42 362 1116 6.25 / 19.50 2 146
Average= 6.50
(KJ/cycle)

Cycle 1 GMT 26/ 4/2024 2:34: 1

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.0 11 275 15.26 404 1695 1.70 / 8.02 2 5
2 6 1024.6 135 73 15.26 1061 1182 2.88 / 9.21 2 22
3 3 1420.1 256 42 15.33 1351 870 3.75 / 10.08 2 25
4 3 1107.2 377 25 15.38 1189 457 4.20 / 10.53 2 30
5 3 761.4 498 8 15.45 994 123 4.33 / 10.66 2 28
6 7 346.7 981 80 15.56 619 771 5.10 / 11.43 2 19
7 13 316.2 987 80 15.52 587 729 5.83 / 12.16 2 12
8 14 0.5 1033 191 15.45 370 1092 6.92 / 13.25 2 142
Average= 6.62
(KJ/cycle)

Cycle 0 GMT 25/ 4/2024 9:14: 0

Number Code Pressure
(db)
Elapsed
Time (m)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 217.0 9574 397 15.49 512 3149 3.15 / 3.15 2 13
2 7 311.2 9576 80 15.39 536 660 3.81 / 3.81 2 3
3 13 368.4 9582 80 15.34 569 698 4.51 / 4.51 2 3
4 13 470.7 9600 80 15.29 643 787 5.29 / 5.29 2 24
5 13 79.5 9654 80 15.30 409 501 5.79 / 5.79 2 27
6 14 2.3 9671 45 15.31 362 249 6.04 / 6.04 2 109
7 14 2.5 9672 55 15.30 340 286 6.33 / 6.33 18 244
Average= 6.33
(KJ/cycle)