SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 3222 WMO= 5907074

Return

Link to WHOI figures

Link to Fleet Monitoring (Coriolis)

Field 1 Field 2 Field 3 Field 4

←PreviousNext→

Cycle 19 GMT 9/11/2024 22:59: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 158 14435 17 7.29 15.40 15.25 10.44 10.71 11.21


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 196 0 2.00 308 -0.08 0.04 0.17 57 2.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1010.48 3.227 34.3456 1013.08 3.222 34.3468 2001.08 1.974 34.6146 0.48 16.197 33.1240


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2904 2956 0 0 0 0 1 0 2 0



Cycle 18 GMT 31/10/2024 3:51: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 166 14559 17 7.29 15.39 15.25 10.40 10.71 11.21


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 203 0 -0.40 308 -0.12 0.08 0.14 57 2.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.48 3.229 34.3450 1010.84 3.223 34.3464 2000.76 1.966 34.6148 0.48 16.274 33.1690


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2912 3001 0 0 0 0 1 0 2 0



Cycle 17 GMT 21/10/2024 8:41: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 14 0 217 14960 17 7.28 15.38 15.24 10.38 10.67 11.17


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 197 0 -0.40 308 0.16 0.00 0.36 57 2.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.28 3.229 34.3450 1010.40 3.222 34.3470 2009.96 1.960 34.6156 0.56 17.916 33.1376


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2923 2958 0 0 0 0 1 0 2 0



Cycle 16 GMT 11/10/2024 13:14:58

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 14 0 226 14668 17 7.28 15.38 15.24 10.37 10.64 11.14


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 200 0 -2.60 308 -0.28 -0.04 0.11 57 2.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1009.36 3.229 34.3450 1011.96 3.224 34.3464 2002.20 1.960 34.6158 0.80 18.707 33.0796


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2915 2961 3 1 0 0 1 0 2 0



Cycle 15 GMT 1/10/2024 18: 0: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 181 14640 17 7.28 15.38 15.21 10.36 10.58 11.16


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 195 300 203 0 -5.30 308 0.08 0.04 0.28 57 2.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.72 3.237 34.3440 1010.84 3.226 34.3462 2002.92 1.950 34.6146 0.64 20.984 33.3122


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2924 2973 0 0 0 0 1 0 2 0



Cycle 14 GMT 21/ 9/2024 22:47:59

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 130 14624 17 7.27 15.37 15.25 10.39 10.55 11.04


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 198 0 4.10 308 0.00 0.08 0.34 57 2.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1006.24 3.244 34.3428 1009.24 3.236 34.3442 2008.36 1.959 34.6132 0.64 22.534 33.3754


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2921 2971 0 0 0 0 1 0 2 0



Cycle 13 GMT 12/ 9/2024 3:34: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 189 14512 16 7.27 15.37 15.25 10.36 10.57 11.04


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 205 0 -6.00 308 -0.12 0.00 0.31 57 2.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1006.36 3.236 34.3436 1010.20 3.233 34.3448 2000.60 1.987 34.6110 0.64 22.599 33.4388


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2912 2952 3 1 0 0 1 0 2 0



Cycle 12 GMT 2/ 9/2024 8:27: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 15 0 267 14656 17 7.28 15.40 15.25 10.35 10.55 11.06


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 189 1 -16.20 308 -0.16 0.12 0.24 57 2.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1003.68 3.253 34.3400 1006.04 3.244 34.3422 2008.76 1.953 34.6160 0.68 21.928 33.4104


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2910 2956 0 0 0 0 1 0 2 0



Cycle 11 GMT 23/ 8/2024 13: 7: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 154 14663 17 7.29 15.41 15.26 10.36 10.56 11.07


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 198 0 -0.30 305 0.00 0.12 0.35 57 2.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1011.32 3.246 34.3432 1014.56 3.229 34.3450 2003.56 1.980 34.6120 0.72 21.368 33.3528


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2891 2947 0 0 0 0 1 0 2 0



Cycle 10 GMT 13/ 8/2024 17:58: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 17 20 5 360 14630 17 7.26 15.37 15.26 10.39 10.54 11.03


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 198 0 -15.40 305 0.12 0.12 0.35 57 2.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1005.76 3.259 34.3414 1009.52 3.248 34.3428 2002.08 2.001 34.6110 0.64 22.934 33.1842


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2892 2930 2 1 0 0 1 0 2 0



Cycle 9 GMT 3/ 8/2024 22:43: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 152 11670 17 7.28 15.41 15.27 10.44 10.56 11.06


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 199 1 -22.00 303 0.04 0.16 0.27 57 2.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1010.76 3.247 34.3428 1014.80 3.236 34.3452 2008.40 1.990 34.6106 0.64 21.455 33.5054


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2887 2928 0 0 0 0 1 0 2 0



Cycle 8 GMT 25/ 7/2024 1:38: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 10 15 0 328 11328 17 7.28 15.42 15.29 10.40 10.67 11.17


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
128 165 300 198 0 5.00 297 0.08 0.08 0.27 57 2.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1011.28 3.238 34.3422 1017.12 3.228 34.3464 2000.76 1.987 34.6130 0.40 19.925 33.4748


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2878 2957 0 0 0 0 1 0 2 0



Cycle 7 GMT 15/ 7/2024 4:30: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 10 10 0 124 10403 17 7.27 15.41 15.29 10.42 10.60 11.11


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 195 0 -12.30 297 -0.08 0.08 0.27 57 2.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1006.68 3.266 34.3364 1004.76 3.254 34.3388 1804.80 2.119 34.5878 0.68 19.893 33.3042


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2652 2728 3 1 0 0 1 0 1 0



Cycle 6 GMT 14/ 7/2024 3:41: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 11 11 0 116 10479 17 7.26 15.40 15.26 10.42 10.62 11.13


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 199 0 -8.30 295 0.08 0.00 0.29 57 2.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.64 3.247 34.3396 1006.72 3.239 34.3406 1814.32 2.128 34.5860 0.64 19.725 33.3120


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2656 2729 0 0 0 0 1 0 1 0



Cycle 5 GMT 13/ 7/2024 2:56: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 11 15 1 295 10338 17 7.26 15.39 15.27 10.44 10.64 11.15


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 198 0 5.00 292 -0.08 0.04 0.23 58 3.0


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
995.84 3.272 34.3362 995.40 3.274 34.3358 1804.56 2.133 34.5834 0.64 19.536 33.3056


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2646 2703 4 1 0 0 1 0 1 0



Cycle 4 GMT 12/ 7/2024 2: 7: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 10 11 0 158 8944 16 7.24 15.39 15.27 10.40 10.69 11.17


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 196 0 -0.10 291 0.12 0.04 0.28 58 3.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.68 3.256 34.3394 1007.96 3.265 34.3372 1502.00 2.445 34.5192 1.12 19.165 33.2942


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2295 2337 0 0 0 0 1 0 1 0



Cycle 3 GMT 11/ 7/2024 2:40: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 10 10 0 101 8990 16 7.24 15.39 15.29 10.40 10.69 11.16


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 190 0 0.00 291 0.04 0.04 0.30 58 3.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
987.56 3.299 34.3310 988.64 3.284 34.3332 1521.88 2.435 34.5216 1.04 19.299 33.2956


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2316 2385 4 1 0 0 1 0 1 0



Cycle 2 GMT 10/ 7/2024 3:18: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 7 8 8 154 8720 17 7.24 15.40 15.28 10.43 10.68 11.18


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 197 2 56.10 280 0.08 0.16 0.30 58 3.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
968.04 3.316 34.3258 973.40 3.343 34.3218 1503.84 2.460 34.5162 0.56 18.958 33.2882


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2292 2339 0 0 0 0 1 0 1 0



Cycle 1 GMT 9/ 7/2024 3:47: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 6 2 6 0 211 4543 17 7.24 15.48 15.34 10.15 10.65 11.18


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 182 1 -38.40 282 -0.08 -0.04 0.22 60 3.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
-999.00 -999.000 -999.000 -999.00 -999.000 -999.000 1006.80 3.230 34.346 0.60 18.970 33.285


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1654 1709 0 0 0 0 1 0 0 0



Cycle 0 GMT 8/ 7/2024 17: 7: 1

#Eng #Pack SatTme (s) SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V1 (inHG) V2 (inHG) RH (%) CPUT (C) SPRX (db) SPRXL (db)
6 2 0 667 17 7.32 15.64 15.59 10.31 11.11 54 17.8 0.52 -0.00


diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) HPavgl (ma) HPmaxl (ma) ExcFlg ISRID AbrtCd
101.72 10.534 33.291 0.44 18.315 33.291 101 240 446 477 0 0 0


BTVcpu (V) BTvac (inHG) BTVple (V) BTavgl (mA) BTPsec (s) BTPvac (inHG) Vent (s/10) VentLD
7.30 9.54 15.57 267 403 10.14 0 0



Cycle -1 GMT 10/ 6/2024 21: 6: 1

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTRH (%) BTCPUT (C)
6 4 -0.26 7.30 15.68 15.57 267.00 403 3 246 9.52 10.87 52 28.8


BTSpt (txt) BTOV BTCV BTInt Fail
"____0.50,_39.8927,__0.0163____" 0 0 6 0