SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 3218 WMO= 3902302

Return

Link to WHOI figures

Link to Fleet Monitoring (Coriolis)

Field 1 Field 2 Field 3 Field 4

←PreviousNext→

Cycle 22 GMT 9/12/2024 12:42: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 12 16 0 311 8428 17 7.25 15.48 15.35 10.62 10.97 11.49


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 216 0 0.60 325 -0.04 -0.04 0.11 59 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1008.48 3.186 34.3428 1011.84 3.183 34.3436 1184.32 2.852 34.4276 0.52 15.709 33.3276


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1881 1905 0 0 0 0 1 0 2 0



Cycle 21 GMT 29/11/2024 16:17: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 18 0 322 14662 17 7.25 15.39 15.26 10.67 10.97 11.49


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 212 0 2.90 324 0.20 -0.04 0.19 59 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.36 3.191 34.3412 1010.00 3.185 34.3428 2010.72 1.984 34.6038 0.56 16.045 33.3846


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2890 2941 0 0 0 0 1 0 2 0



Cycle 20 GMT 19/11/2024 20:40: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 9 9 0 98 14803 17 7.25 15.38 15.25 10.60 10.96 11.47


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 210 0 -1.00 324 -0.20 0.04 0.09 59 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1000.36 3.206 34.3370 1002.84 3.199 34.3388 2002.04 1.983 34.6038 0.44 16.458 33.2122


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2873 2904 0 0 0 0 1 0 2 0



Cycle 19 GMT 10/11/2024 0:34: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 12 14 0 211 8224 17 7.25 15.50 15.37 10.65 10.89 11.41


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 197 0 -1.00 324 -0.24 0.04 -0.02 58 1.5


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1008.04 3.200 34.3384 1009.84 3.188 34.3416 1162.52 2.911 34.4102 0.48 18.418 33.3220


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1853 1876 0 0 0 0 1 0 2 0



Cycle 18 GMT 31/10/2024 4:14:58

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 194 14654 17 7.26 15.39 15.26 10.63 10.89 11.40


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 199 0 -0.50 324 -0.04 -0.12 -0.01 59 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1012.76 3.195 34.3400 1015.84 3.187 34.3420 2009.20 1.977 34.6016 0.68 18.789 33.4272


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2893 2926 0 0 0 0 1 0 2 0



Cycle 17 GMT 21/10/2024 8:54: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 9 10 0 142 14568 17 7.25 15.38 15.25 10.67 10.90 11.41


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
128 165 300 212 0 0.60 323 0.20 -0.04 0.31 59 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.12 3.218 34.3336 1007.12 3.210 34.3358 2008.96 1.985 34.6002 0.48 20.169 33.3848


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2894 2926 0 0 0 0 1 0 2 0



Cycle 16 GMT 11/10/2024 13:39:59

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 11 14 0 213 7994 17 7.25 15.49 15.36 10.67 10.89 11.41


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
93 165 300 203 0 0.00 323 -0.36 0.00 0.00 58 1.5


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1008.48 3.213 34.3350 1011.52 3.206 34.3368 1113.96 3.025 34.3838 0.32 20.996 33.2334


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1800 1830 3 1 0 0 1 0 2 0



Cycle 15 GMT 1/10/2024 17:24: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 12 13 0 169 13048 17 7.25 15.42 15.29 10.66 10.84 11.34


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 206 0 5.70 323 0.00 -0.04 0.11 59 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.68 3.225 34.3322 1008.24 3.218 34.3338 1756.56 2.163 34.5680 0.56 21.773 33.3102


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2585 2608 0 0 0 0 1 0 2 0



Cycle 14 GMT 21/ 9/2024 19:46: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 9 11 0 191 14163 17 7.25 15.38 15.25 10.64 10.86 11.35


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
128 165 300 202 0 -0.50 322 -0.04 -0.04 0.11 59 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1009.32 3.218 34.3338 1012.44 3.207 34.3366 1956.28 2.021 34.5938 0.40 22.545 33.4980


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2822 2858 0 0 0 0 1 0 2 0



Cycle 13 GMT 11/ 9/2024 21:48: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 12 18 0 377 7639 17 7.26 15.50 15.38 10.68 10.85 11.35


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
92 165 300 207 0 6.10 321 0.04 -0.04 0.15 58 1.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1006.72 3.226 34.3320 1010.96 3.215 34.3346 1087.76 3.083 34.3720 0.32 22.813 33.4014


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1758 1778 0 0 0 0 1 0 2 0



Cycle 12 GMT 2/ 9/2024 1:35: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 9 9 0 85 14930 17 7.25 15.40 15.27 10.68 10.86 11.35


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
128 165 300 208 0 0.00 320 -0.04 0.12 0.13 59 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1006.44 3.227 34.3316 1009.88 3.219 34.3336 2009.04 1.981 34.6006 0.60 22.189 33.2528


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2889 2928 0 0 0 0 1 0 2 0



Cycle 11 GMT 23/ 8/2024 5: 0: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 12 14 0 237 7989 17 7.26 15.51 15.38 10.68 10.81 11.32


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 197 0 -5.00 321 0.00 -0.08 0.12 58 1.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1008.12 3.225 34.3324 1011.92 3.212 34.3352 1103.44 3.053 34.3794 0.68 21.847 33.2376


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1774 1788 0 0 0 0 1 0 2 0



Cycle 10 GMT 13/ 8/2024 8:44: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 18 21 5 353 14947 17 7.26 15.40 15.27 10.69 10.86 11.34


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
128 165 300 201 0 7.00 319 -0.12 -0.08 0.09 59 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1009.20 3.221 34.3338 1013.56 3.212 34.3360 2003.84 1.973 34.6014 0.48 22.891 33.2324


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2878 2915 0 0 0 0 1 0 2 0



Cycle 9 GMT 3/ 8/2024 12:37: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 12 13 0 220 11568 17 7.25 15.40 15.28 10.71 10.90 11.40


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
128 165 300 191 1 -29.60 316 -0.28 -0.12 -0.11 59 0.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1009.88 3.223 34.3336 1014.64 3.208 34.3370 2010.28 1.993 34.5994 0.48 20.541 33.1546


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2877 2933 0 0 0 0 1 0 2 0



Cycle 8 GMT 24/ 7/2024 15: 1: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 11 13 0 200 11913 17 7.25 15.41 15.28 10.68 10.92 11.42


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
128 165 300 201 1 -14.90 309 0.08 0.08 0.02 59 0.5


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1009.60 3.219 34.3342 1015.60 3.206 34.3374 2006.88 1.996 34.5990 0.48 19.724 33.2270


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2863 2912 5 1 0 0 1 0 2 0



Cycle 7 GMT 14/ 7/2024 15:47: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 11 11 1 155 10827 17 7.26 15.41 15.27 10.69 10.84 11.35


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 198 9 29.60 1 -0.04 -0.04 0.01 59 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1097.88 3.053 34.3786 1097.92 3.062 34.3762 1803.28 2.108 34.5786 0.56 20.483 33.4662


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2632 2668 4 1 0 0 1 0 1 0



Cycle 6 GMT 13/ 7/2024 14:47: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 8 8 0 94 10563 17 7.26 15.40 15.27 10.73 10.92 11.42


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
129 165 300 203 0 -13.90 298 0.00 -0.04 0.00 59 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1002.80 3.229 34.3320 1004.80 3.227 34.3326 1802.24 2.116 34.5772 0.36 20.308 33.4114


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2625 2681 0 0 0 0 1 0 1 0



Cycle 5 GMT 12/ 7/2024 13:18: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 8 9 13 2 294 5516 17 7.25 15.49 15.36 10.74 10.93 11.43


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
92 165 300 200 0 -5.30 296 -0.04 -0.04 0.00 59 1.5


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.68 3.218 34.3348 1007.60 3.231 34.3318 1150.04 2.934 34.4062 0.48 19.811 33.3942


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1820 1855 4 1 0 0 1 0 1 0



Cycle 4 GMT 11/ 7/2024 10:11: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 8 8 8 0 102 5060 17 7.25 15.49 15.36 10.75 10.96 11.46


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
93 165 300 199 1 -28.80 295 0.00 -0.08 0.01 59 1.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.12 3.212 34.3356 1007.32 3.227 34.3322 1074.72 3.087 34.3720 0.36 19.215 33.0790


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1729 1765 0 0 0 0 1 0 1 0



Cycle 3 GMT 10/ 7/2024 10:54: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 8 8 8 0 93 5930 17 7.25 15.48 15.35 10.74 10.95 11.44


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
92 165 300 205 1 27.00 290 -0.04 0.04 0.07 59 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
995.12 3.227 34.3314 998.28 3.254 34.3252 1205.16 2.861 34.4210 0.60 18.782 33.0562


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1889 1927 0 0 0 0 1 0 1 0



Cycle 2 GMT 9/ 7/2024 11:18: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 8 7 7 0 90 4631 17 7.24 15.52 15.39 10.73 10.91 11.42


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 197 2 47.60 289 -0.08 -0.04 0.02 59 1.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
970.40 3.292 34.3144 971.64 3.297 34.3138 1011.48 3.165 34.3486 0.64 18.860 33.0648


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1649 1679 0 0 0 0 1 0 1 0



Cycle 1 GMT 8/ 7/2024 12: 7: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 7 3 6 4 273 4667 17 7.24 15.50 15.37 10.42 10.91 11.42


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 199 1 32.50 288 -0.08 -0.04 -0.04 62 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
-999.00 -999.000 -999.0000 -999.00 -999.000 -999.0000 1002.16 3.205 34.3388 0.64 18.275 33.0434


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1635 1684 0 0 0 0 1 0 0 0



Cycle 0 GMT 8/ 7/2024 1:29: 1

#Eng #Pack SatTme (s) SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V1 (inHG) V2 (inHG) RH (%) CPUT (C) SPRX (db) SPRXL (db)
6 2 0 737 17 7.30 15.63 15.58 10.55 11.29 54 16.6 -0.12 -0.04


diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) HPavgl (ma) HPmaxl (ma) ExcFlg ISRID AbrtCd
98.60 10.227 33.122 0.48 18.668 33.030 102 240 419 429 0 0 0


BTVcpu (V) BTvac (inHG) BTVple (V) BTavgl (mA) BTPsec (s) BTPvac (inHG) Vent (s/10) VentLD
7.28 9.88 15.56 254 418 7.59 0 0



Cycle -1 GMT 10/ 6/2024 20:48: 1

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTRH (%) BTCPUT (C)
6 4 0.12 7.28 15.68 15.56 254.00 418 2 247 9.88 11.17 55 26.2


BTSpt (txt) BTOV BTCV BTInt Fail
"___-0.12,_39.4097,__0.0000____" 0 0 6 0