SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 3248 WMO= 5906954

Return

Link to WHOI figures

Link to Fleet Monitoring (Coriolis)

Field 1 Field 2 Field 3 Field 4

←PreviousNext→

Cycle 19 GMT 13/12/2024 10:45: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 13 14 0 215 14589 17 7.25 15.34 15.25 10.60 10.91 11.01


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 191 0 -4.70 323 0.08 -0.12 0.28 59 1.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1012.76 3.626 34.2754 1016.48 3.637 34.2738 2005.52 2.046 34.5790 0.36 18.714 34.4976


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2823 2864 0 0 0 0 1 0 2 0



Cycle 18 GMT 3/12/2024 15:43: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 13 14 0 234 14291 17 7.25 15.36 15.27 10.59 10.89 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 203 0 -12.10 320 -0.12 -0.04 0.15 59 2.0


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.80 3.555 34.2882 1010.04 3.583 34.2832 2002.36 2.018 34.5878 0.52 19.532 34.4968


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2811 2837 4 1 0 0 1 0 2 0



Cycle 17 GMT 23/11/2024 20:43: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 13 13 0 217 14974 17 7.25 15.36 15.26 10.55 10.85 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 192 0 -10.00 319 -0.16 -0.08 0.12 59 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1006.24 3.480 34.3014 1011.44 3.504 34.2970 2001.44 1.971 34.5984 0.60 21.225 34.6178


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2822 2857 0 0 0 0 1 0 2 0



Cycle 16 GMT 14/11/2024 1:22: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 13 20 0 413 15133 17 7.24 15.35 15.26 10.58 10.85 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 210 0 3.70 317 0.08 -0.08 0.27 59 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1001.32 3.434 34.3098 1005.72 3.449 34.3072 2002.52 1.977 34.5974 0.64 21.410 34.5060


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2828 2854 0 0 0 0 1 0 2 0



Cycle 15 GMT 4/11/2024 6: 5: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 14 17 0 279 14672 16 7.25 15.36 15.27 10.59 10.84 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 198 0 -3.60 317 -0.16 0.12 0.14 59 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1009.64 3.350 34.3250 1014.52 3.367 34.3222 2001.56 1.944 34.5992 0.76 22.043 34.3676


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2828 2864 0 0 0 0 1 0 2 0



Cycle 14 GMT 25/10/2024 10:50: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 14 13 15 0 239 15049 17 7.24 15.34 15.25 10.59 10.87 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
128 165 300 193 0 0.80 317 0.08 -0.08 0.22 59 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1001.84 3.364 34.3224 1004.92 3.363 34.3226 2002.12 1.922 34.6008 0.52 22.545 34.5550


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2824 2851 0 0 0 0 1 0 2 0



Cycle 13 GMT 15/10/2024 15:36: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 14 17 0 274 15165 17 7.24 15.36 15.27 10.62 10.80 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 203 0 7.40 319 -0.08 -0.08 0.16 59 1.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
998.84 3.369 34.3220 1000.24 3.355 34.3244 2008.52 1.898 34.6026 0.44 23.802 34.4226


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2827 2861 0 0 0 0 1 0 2 0



Cycle 12 GMT 5/10/2024 20:13: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 14 14 15 0 183 14587 17 7.24 15.36 15.27 10.51 10.81 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 196 0 7.10 319 0.00 -0.08 0.17 59 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1011.68 3.420 34.3132 1011.12 3.373 34.3214 2002.36 1.927 34.5978 0.56 23.215 34.4094


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2821 2858 0 0 0 0 1 0 2 0



Cycle 11 GMT 26/ 9/2024 1: 6:59

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 14 14 16 0 203 14383 17 7.24 15.36 15.27 10.60 10.72 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 198 0 6.00 318 -0.04 -0.04 0.19 59 1.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1008.80 3.466 34.3034 1011.00 3.444 34.3076 2007.32 1.948 34.5954 0.56 26.330 34.5778


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2827 2856 0 0 0 0 1 0 2 0



Cycle 10 GMT 16/ 9/2024 6: 3: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 14 13 13 0 194 14942 17 7.24 15.35 15.26 10.59 10.73 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 211 0 -9.10 318 -0.08 0.08 0.15 59 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.52 3.547 34.2878 1009.48 3.514 34.2940 2008.72 1.985 34.5926 0.60 25.859 34.3610


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2831 2871 0 0 0 0 1 0 2 0



Cycle 9 GMT 6/ 9/2024 10:52: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 14 19 0 353 14554 17 7.25 15.37 15.28 10.60 10.76 11.01


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 207 0 -12.60 317 -0.08 0.00 0.15 59 2.0


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1010.68 3.574 34.2830 1012.76 3.549 34.2876 2006.16 2.029 34.5844 0.48 25.256 34.5514


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2822 2852 0 0 0 0 1 0 2 0



Cycle 8 GMT 27/ 8/2024 15:37: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 14 14 17 0 277 14323 17 7.25 15.38 15.28 10.61 10.77 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 207 0 -10.00 316 -0.04 -0.08 0.18 59 1.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1013.28 3.535 34.2904 1019.84 3.540 34.2892 2003.68 2.021 34.5810 0.56 25.049 34.5728


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2793 2853 0 0 0 0 1 0 2 0



Cycle 7 GMT 17/ 8/2024 20:28: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 14 16 20 14 357 14690 17 7.25 15.37 15.29 10.65 10.77 11.01


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 186 1 -4.20 312 0.04 -0.08 0.23 59 1.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1005.40 3.438 34.3078 1015.60 3.472 34.3016 2002.16 2.001 34.5806 0.56 24.458 34.5038


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2788 2830 0 0 0 0 1 0 2 0



Cycle 6 GMT 8/ 8/2024 1:14: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 11 13 0 212 11871 17 7.24 15.39 15.29 10.63 10.85 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
129 165 300 197 1 -29.40 306 -0.24 0.00 0.10 59 1.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1010.28 3.376 34.320 1016.32 3.367 34.322 2009.60 1.984 34.585 0.60 23.706 34.332


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2766 2826 4 1 0 0 1 0 2 0



Cycle 5 GMT 29/ 7/2024 4: 4: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 8 8 0 123 11970 17 7.25 15.42 15.33 10.68 10.79 11.01


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 175 1 51.30 298 0.12 -0.04 0.15 58 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1009.80 3.482 34.299 1013.04 3.416 34.312 2009.36 1.990 34.585 0.68 24.181 34.389


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2775 2857 0 0 0 0 1 0 2 0



Cycle 4 GMT 19/ 7/2024 6:48: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 8 9 9 0 129 9382 17 7.25 15.42 15.34 10.68 10.83 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 191 0 2.50 296 0.08 -0.04 0.16 59 2.5


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
996.60 3.493 34.297 999.24 3.498 34.296 1502.76 2.512 34.486 0.60 23.070 34.295


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2165 2216 0 0 0 0 1 0 1 0



Cycle 3 GMT 18/ 7/2024 7:13: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 9 10 0 141 9021 17 7.26 15.42 15.32 10.69 10.86 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 192 0 0.20 297 -0.08 0.00 0.14 59 2.5


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
986.12 3.540 34.288 985.76 3.523 34.292 1519.00 2.474 34.491 0.60 22.826 34.362


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2191 2251 0 0 0 0 1 0 1 0



Cycle 2 GMT 17/ 7/2024 7:40: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 6 8 0 184 9331 17 7.26 15.42 15.33 10.70 10.84 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 180 2 96.30 300 -0.04 0.04 0.15 59 2.5


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1024.28 3.434 34.308 1024.72 3.419 34.311 1513.44 2.500 34.487 0.56 23.159 34.418


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2187 2233 0 0 0 0 1 0 1 0



Cycle 1 GMT 16/ 7/2024 8: 6: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 6 3 7 0 150 4513 17 7.25 15.48 15.40 10.46 10.85 11.02


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 186 1 -29.60 288 -0.16 0.00 0.05 62 3.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
-999.00 -999.000 -999.000 -999.00 -999.000 -999.000 1007.40 3.477 34.299 0.48 23.113 34.481


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1548 1612 0 0 0 0 1 0 0 0



Cycle 0 GMT 15/ 7/2024 21:26: 0

#Eng #Pack SatTme (s) SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V1 (inHG) V2 (inHG) RH (%) CPUT (C) SPRX (db) SPRXL (db)
6 3 0 682 17 7.31 15.63 15.60 10.59 11.02 52 19.0 0.08 -0.00


diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) HPavgl (ma) HPmaxl (ma) ExcFlg ISRID AbrtCd
109.24 14.003 34.421 0.32 22.776 4.054 102 240 379 390 0 0 0


BTVcpu (V) BTvac (inHG) BTVple (V) BTavgl (mA) BTPsec (s) BTPvac (inHG) Vent (s/10) VentLD
7.30 10.22 15.62 205 362 6.45 0 0



Cycle -1 GMT 10/ 6/2024 20:54: 0

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTRH (%) BTCPUT (C)
6 4 0.19 7.30 15.71 15.62 205.00 362 2 133 10.22 11.02 54 24.1


BTSpt (txt) BTOV BTCV BTInt Fail
"____0.08,_35.4831,__0.0000____" 0 0 6 0