SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 3244 WMO= 5906948

Return

Link to WHOI figures

Link to Fleet Monitoring (Coriolis)

Field 1 Field 2 Field 3 Field 4

←PreviousNext→

Cycle 19 GMT 16/11/2024 20:44: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 206 14853 17 7.26 15.35 15.26 10.19 10.58 11.06


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 191 0 5.50 308 0.28 -0.04 0.26 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
999.56 3.438 34.3058 1001.24 3.434 34.3066 2008.96 2.017 34.5802 0.52 17.554 34.1790


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2854 2910 0 0 0 0 1 0 2 0



Cycle 18 GMT 7/11/2024 1:17: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 15 0 221 14649 17 7.25 15.34 15.25 10.17 10.54 11.03


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 194 0 -4.30 307 0.40 0.48 0.69 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1010.32 3.411 34.3106 1013.00 3.408 34.3112 2008.16 2.007 34.5812 0.56 18.938 34.3418


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2859 2933 0 0 0 0 1 0 2 0



Cycle 17 GMT 28/10/2024 5:55: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 18 0 326 14290 17 7.26 15.36 15.23 10.15 10.49 11.05


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 195 300 183 0 -3.70 307 0.12 0.20 0.34 63 0.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1012.56 3.397 34.3138 1015.36 3.402 34.3128 2001.52 2.047 34.5760 0.64 20.180 34.3152


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2850 2887 0 0 0 0 1 0 2 0



Cycle 16 GMT 18/10/2024 10:43:59

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 190 14517 17 7.26 15.35 15.25 10.20 10.46 10.95


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 202 0 2.60 306 -0.08 -0.16 0.00 63 0.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.16 3.408 34.3120 1006.36 3.402 34.3132 2008.44 2.022 34.5790 0.72 21.650 34.3460


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2855 2909 0 0 0 0 1 0 2 0



Cycle 15 GMT 8/10/2024 15:27: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 175 14300 17 7.25 15.35 15.25 10.18 10.46 10.95


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 187 0 0.80 305 0.40 0.12 0.51 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1012.56 3.380 34.3170 1014.68 3.373 34.3186 2010.00 2.017 34.5798 0.48 21.972 34.1396


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2850 2931 3 1 0 0 1 0 2 0



Cycle 14 GMT 28/ 9/2024 20:12: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 186 14531 17 7.25 15.35 15.23 10.13 10.40 10.96


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 195 300 199 0 1.30 305 -0.36 -0.24 -0.15 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1011.16 3.388 34.3156 1014.00 3.385 34.3166 2007.08 2.023 34.5790 0.72 23.677 34.0470


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2865 2903 0 0 0 0 1 0 2 0



Cycle 13 GMT 19/ 9/2024 0:46: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 15 0 217 14916 17 7.25 15.35 15.26 10.20 10.35 10.84


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 197 0 7.20 305 -0.40 -0.32 -0.20 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1009.56 3.373 34.3184 1013.36 3.380 34.3174 2004.92 1.999 34.5838 0.52 24.937 34.2562


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2848 2887 0 0 0 0 1 0 2 0



Cycle 12 GMT 9/ 9/2024 5:18: 3

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 15 0 309 14758 17 7.26 15.37 15.27 10.20 10.38 10.87


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 190 0 4.10 305 0.08 0.20 0.30 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1008.12 3.361 34.3214 1011.32 3.360 34.3208 2002.96 1.993 34.5848 0.68 24.656 34.1876


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2844 2885 3 1 0 0 1 0 2 0



Cycle 11 GMT 30/ 8/2024 9:58: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 157 14584 17 7.26 15.36 15.27 10.20 10.37 10.85


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 198 0 6.40 305 0.12 0.12 0.25 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1004.80 3.356 34.3226 1007.88 3.356 34.3226 2000.68 2.000 34.5838 0.52 25.199 33.9974


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2849 2923 0 0 0 0 1 0 2 0



Cycle 10 GMT 20/ 8/2024 14:46: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 192 14453 17 7.26 15.38 15.27 10.18 10.40 10.89


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 194 0 -0.30 305 -0.24 -0.20 -0.05 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
999.00 3.394 34.3152 1000.68 3.373 34.3196 2007.80 1.978 34.5880 0.64 23.980 34.1824


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2854 2907 0 0 0 0 1 0 2 0



Cycle 9 GMT 10/ 8/2024 19:26: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 18 19 5 267 14459 17 7.26 15.38 15.28 10.13 10.40 10.90


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 187 1 32.60 306 -0.28 -0.08 -0.04 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1002.32 3.471 34.3008 1004.04 3.427 34.3090 2007.48 1.993 34.5852 0.48 23.774 34.3646


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2852 2913 4 1 0 0 1 0 2 0



Cycle 8 GMT 1/ 8/2024 0: 6: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 13 11 11 0 150 11055 17 7.25 15.38 15.28 10.21 10.39 10.86


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 178 1 -20.80 297 -0.24 -0.36 -0.16 63 0.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1002.88 3.511 34.2928 1006.64 3.477 34.2988 2002.80 2.004 34.5812 0.72 24.653 34.2654


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2831 2896 0 0 0 0 1 0 2 0



Cycle 7 GMT 22/ 7/2024 3: 2: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 10 12 0 192 10423 17 7.24 15.37 15.27 10.21 10.42 10.91


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 179 0 1.20 295 0.24 0.32 0.41 63 1.0


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1012.32 3.504 34.2932 1012.76 3.507 34.2928 1805.88 2.182 34.5472 0.68 22.940 34.3958


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2584 2649 0 0 0 0 1 0 1 0



Cycle 6 GMT 21/ 7/2024 2:11: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 11 12 0 144 10203 17 7.25 15.37 15.27 10.23 10.42 10.90


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 189 1 -14.20 295 0.24 0.24 0.36 63 1.0


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1006.20 3.517 34.2922 1006.52 3.522 34.2918 1810.16 2.185 34.5458 0.60 23.022 34.4296


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2592 2648 4 1 0 0 1 0 1 0



Cycle 5 GMT 20/ 7/2024 1:25: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 11 11 2 133 10176 17 7.24 15.37 15.28 10.21 10.43 10.91


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 191 0 7.90 291 -0.20 -0.12 -0.07 63 1.0


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
998.64 3.556 34.2864 995.28 3.497 34.2956 1811.48 2.164 34.5502 0.56 22.901 34.4322


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2591 2670 0 0 0 0 1 0 1 0



Cycle 4 GMT 19/ 7/2024 0:40: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 9 12 0 189 8858 17 7.25 15.39 15.29 10.20 10.42 10.91


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 182 0 -10.60 290 0.24 0.16 0.31 63 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1003.96 3.528 34.2910 1004.08 3.504 34.2942 1522.24 2.485 34.4870 0.48 23.066 34.4946


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2240 2279 0 0 0 0 1 0 1 0



Cycle 3 GMT 18/ 7/2024 1: 8: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 10 12 0 255 8731 17 7.25 15.39 15.30 10.22 10.42 10.90


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 180 1 -33.60 288 0.00 0.04 0.16 63 1.5


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1005.52 3.498 34.2962 1008.04 3.494 34.2968 1502.60 2.529 34.4798 0.48 23.476 34.5608


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2222 2276 0 0 0 0 1 0 1 0



Cycle 2 GMT 17/ 7/2024 1:40: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 10 7 7 0 94 8663 17 7.24 15.39 15.29 10.25 10.41 10.88


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 185 2 53.30 279 0.36 0.32 0.44 64 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
975.64 3.596 34.2806 979.92 3.601 34.2794 1516.96 2.502 34.4852 0.48 24.827 34.5532


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2235 2284 0 0 0 0 1 0 1 0



Cycle 1 GMT 16/ 7/2024 2: 7: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 7 3 3 4 68 4421 17 7.23 15.46 15.35 9.95 10.43 10.90


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 183 1 -34.80 280 -0.08 0.04 0.10 66 2.0


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
-999.00 -999.000 -999.0000 -999.00 -999.000 -999.0000 1009.84 3.445 34.3064 0.60 22.521 34.7196


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1600 1643 0 0 0 0 1 0 0 0



Cycle 0 GMT 15/ 7/2024 15:30: 0

#Eng #Pack SatTme (s) SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V1 (inHG) V2 (inHG) RH (%) CPUT (C) SPRX (db) SPRXL (db)
6 2 0 535 17 7.29 15.60 15.56 10.16 10.85 60 20.0 -0.00 -0.00


diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) HPavgl (ma) HPmaxl (ma) ExcFlg ISRID AbrtCd
83.60 15.093 34.519 0.36 22.548 34.474 101 240 376 395 0 0 0


BTVcpu (V) BTvac (inHG) BTVple (V) BTavgl (mA) BTPsec (s) BTPvac (inHG) Vent (s/10) VentLD
7.29 9.46 15.59 212 405 7.57 0 0



Cycle -1 GMT 10/ 6/2024 21: 2: 1

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTRH (%) BTCPUT (C)
6 4 0.30 7.29 15.69 15.59 212.00 405 2 245 9.46 10.70 60 28.8


BTSpt (txt) BTOV BTCV BTInt Fail
"___-0.03,_40.7620,__0.0000____" 0 0 6 0