SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 3238 WMO= 5906943

Return

Link to WHOI figures

Link to Fleet Monitoring (Coriolis)

Field 1 Field 2 Field 3 Field 4

←PreviousNext→

Cycle 19 GMT 13/11/2024 21:58: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 125 14212 17 7.26 15.39 15.25 10.42 10.69 11.00


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
92 165 300 197 0 -1.80 303 0.32 -0.04 0.34 59 1.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
998.40 3.390 34.2980 1000.16 3.390 34.2980 2007.24 2.008 34.5832 0.72 15.576 33.7696


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2898 2962 0 0 0 0 1 0 2 0



Cycle 18 GMT 4/11/2024 1:48:59

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 174 14449 17 7.26 15.38 15.25 10.42 10.67 10.98


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
92 165 300 207 0 -1.20 304 -0.04 -0.04 0.34 59 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1002.12 3.393 34.2976 1003.40 3.387 34.2984 2002.96 2.023 34.5794 0.76 16.436 33.7642


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2891 2963 0 0 0 0 1 0 2 0



Cycle 17 GMT 25/10/2024 5:32: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 17 0 326 14317 16 7.27 15.38 15.25 10.42 10.65 10.97


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
92 165 300 197 0 2.90 304 -0.04 -0.04 0.32 59 1.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1001.96 3.393 34.2976 1004.24 3.388 34.2984 2008.60 2.034 34.5788 0.80 17.284 33.9906


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2900 2961 0 0 0 0 1 0 2 0



Cycle 16 GMT 15/10/2024 6:40: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 190 14108 17 7.27 15.39 15.26 10.33 10.67 10.99


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 201 0 0.70 304 0.00 -0.04 0.37 59 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1014.36 3.369 34.3018 1016.32 3.360 34.3036 2002.32 2.032 34.5792 0.52 18.234 33.9980


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2891 2967 0 0 0 0 1 0 2 0



Cycle 15 GMT 5/10/2024 8:26: 2

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 14 0 236 14458 17 7.26 15.37 15.25 10.43 10.64 10.97


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 197 0 -8.60 302 0.08 0.08 0.54 59 1.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.20 3.391 34.2974 1008.92 3.381 34.2994 2008.88 2.036 34.5788 0.44 19.458 34.0428


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2897 2954 0 0 0 0 1 0 2 0



Cycle 14 GMT 25/ 9/2024 12:38: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 14 0 200 14490 17 7.26 15.38 15.24 10.45 10.60 10.92


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 197 0 5.10 301 -0.20 -0.04 0.25 59 1.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1011.80 3.381 34.3000 1014.08 3.377 34.3004 2002.28 2.008 34.5802 0.60 21.110 34.0358


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2887 2948 0 0 0 0 1 0 2 0



Cycle 13 GMT 15/ 9/2024 15:50: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 13 0 181 14461 17 7.27 15.39 15.26 10.42 10.60 10.92


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 201 0 6.90 301 0.00 0.16 0.39 59 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1000.68 3.419 34.2926 1003.12 3.412 34.2940 2001.24 2.024 34.5764 0.36 20.722 34.0592


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2896 2930 0 0 0 0 1 0 2 0



Cycle 12 GMT 5/ 9/2024 19:17: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 1 178 14159 17 7.26 15.38 15.25 10.41 10.59 10.92


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 188 0 -0.90 301 0.08 0.04 0.37 59 1.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1011.96 3.394 34.2972 1013.60 3.386 34.2990 2005.36 1.994 34.5816 0.64 21.340 34.0760


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2895 2956 0 0 0 0 1 0 2 0



Cycle 11 GMT 26/ 8/2024 23: 6: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 11 12 12 0 137 10713 17 7.27 15.44 15.31 10.43 10.53 10.85


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
93 165 300 191 1 -14.80 301 -0.08 0.04 0.37 59 1.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1003.84 3.407 34.2948 1006.60 3.399 34.2966 1516.16 2.494 34.4788 0.52 23.529 34.4382


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2279 2316 0 0 0 0 1 0 2 0



Cycle 10 GMT 17/ 8/2024 2: 3: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 17 17 5 221 13707 17 7.27 15.40 15.28 10.45 10.56 10.88


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 186 0 0.70 298 0.12 0.08 0.46 59 1.1


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1012.56 3.377 34.3004 1015.56 3.373 34.3012 1957.52 2.028 34.5748 0.44 22.833 33.9906


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2841 2889 3 1 0 0 1 0 2 0



Cycle 9 GMT 7/ 8/2024 4:10: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 12 12 0 124 10536 17 7.27 15.40 15.30 10.47 10.63 10.93


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
111 165 300 191 0 4.30 298 -0.32 -0.12 0.20 59 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
982.00 3.454 34.2856 985.88 3.443 34.2878 1903.64 2.092 34.5630 0.60 20.069 33.8830


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2750 2816 0 0 0 0 1 0 2 0



Cycle 8 GMT 28/ 7/2024 4:42: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 12 9 9 0 101 11402 17 7.26 15.40 15.29 10.48 10.62 10.92


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 182 0 2.00 289 -0.12 -0.12 0.20 59 1.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
986.20 3.436 34.2884 992.40 3.421 34.2916 2007.76 2.000 34.5814 0.64 21.051 33.9380


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2875 2940 0 0 0 0 1 0 2 0



Cycle 7 GMT 18/ 7/2024 6:27: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 8 10 0 193 9204 17 7.27 15.41 15.29 10.48 10.67 10.99


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
110 165 300 176 0 0.00 284 0.04 -0.08 0.24 60 1.8


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.00 3.382 34.2980 1006.44 3.385 34.2984 1617.76 2.351 34.5052 0.44 18.170 33.7658


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2397 2471 0 0 0 0 1 0 1 0



Cycle 6 GMT 17/ 7/2024 5:56: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 8 9 10 0 165 6300 17 7.26 15.45 15.34 10.49 10.69 11.00


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
93 165 300 185 0 -3.20 284 -0.16 0.04 0.17 60 2.2


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1010.40 3.389 34.2972 1010.84 3.367 34.3004 1308.00 2.778 34.4152 0.48 17.970 33.7572


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1999 2054 0 0 0 0 1 0 1 0



Cycle 5 GMT 16/ 7/2024 6:17: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 10 11 1 181 7564 17 7.25 15.43 15.32 10.47 10.67 10.99


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
93 165 300 186 1 -30.90 283 -0.08 0.00 0.24 59 1.9


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1003.16 3.403 34.2940 1000.68 3.384 34.2976 1434.44 2.605 34.4522 0.76 17.988 33.7580


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2162 2217 0 0 0 0 1 0 1 0



Cycle 4 GMT 15/ 7/2024 6:16: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 9 8 9 0 143 8728 17 7.25 15.42 15.32 10.49 10.63 10.96


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
92 165 300 194 0 -0.40 278 -0.08 0.08 0.22 60 2.1


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1007.68 3.382 34.2976 1004.68 3.362 34.3018 1508.04 2.493 34.4778 0.72 18.121 33.7554


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
2252 2308 3 1 0 0 1 0 1 0



Cycle 3 GMT 14/ 7/2024 6:22: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 8 8 8 0 118 5660 17 7.25 15.50 15.37 10.47 10.65 10.98


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 184 1 -18.20 278 0.12 0.04 0.25 59 2.1


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
1000.96 3.387 34.2952 1003.48 3.399 34.2940 1229.08 2.933 34.3818 0.60 18.321 33.8406


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1894 1946 0 0 0 0 1 0 1 0



Cycle 2 GMT 13/ 7/2024 6:54: 1

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 8 7 12 0 227 4618 17 7.24 15.50 15.39 10.47 10.68 10.97


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
75 165 300 193 2 57.20 273 0.04 0.04 0.25 60 2.4


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
954.08 3.517 34.2704 959.84 3.532 34.2670 1059.68 3.243 34.3238 0.60 18.321 33.9412


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1682 1742 0 0 0 0 1 0 1 0



Cycle 1 GMT 12/ 7/2024 7:42: 0

#Eng #Pack #SentP #ConnP #ParsP SatTme SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V0 (inHG) V1 (inHG) V2 (inHG)
6 7 3 3 4 59 4202 17 7.24 15.49 15.37 10.21 10.68 10.98


PmtoSf (s) PmSf (s) FallTm (s) FallRt (mm/s) SeekTm (s) SeekP (db) PP>TIP (s/10) SPRX (db) SPRXL (db) PCorr (db) RH (%) CPUT (C)
74 165 300 182 0 1.60 278 -0.08 -0.04 0.11 62 2.6


Pavg0 (db) Tavg0 (C) Savg0 (psu) Pavg1 (db) Tavg1 (C) Savg1 (psu) diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu)
-999.00 -999.000 -999.0000 -999.00 -999.000 -999.0000 980.36 3.473 34.2790 0.44 18.256 33.9486


HPavgI (ma) HPmaxI (ma) Vent (s/10) VentLD ExcFlg ISRID ATSBD #BinM #SubCy #IceDt
1582 1630 2 1 0 0 1 0 0 0



Cycle 0 GMT 11/ 7/2024 21: 9: 1

#Eng #Pack SatTme (s) SBscan SBstat Vcpu (V) Vpmp (V) Vple (V) V1 (inHG) V2 (inHG) RH (%) CPUT (C) SPRX (db) SPRXL (db)
6 2 0 412 17 7.30 15.63 15.58 10.39 11.08 54 19.1 -0.00 -0.00


diagP0 (db) diagT0 (C) diagS0 (psu) diagP1 (db) diagT1 (C) diagS1 (psu) PmtoSf (s) PmSf (s) HPavgl (ma) HPmaxl (ma) ExcFlg ISRID AbrtCd
60.56 13.025 34.221 0.40 18.154 33.944 100 240 343 357 0 0 0


BTVcpu (V) BTvac (inHG) BTVple (V) BTavgl (mA) BTPsec (s) BTPvac (inHG) Vent (s/10) VentLD
7.31 9.65 15.59 218 379 9.58 0 0



Cycle -1 GMT 10/ 6/2024 21: 2: 1

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTRH (%) BTCPUT (C)
6 4 0.28 7.31 15.70 15.59 218.00 379 3 190 9.65 10.75 53 29.1


BTSpt (txt) BTOV BTCV BTInt Fail
"____0.04,_39.8586,__0.0000____" 0 0 6 0