SIO Argo Site:
Pump Diagnostics Page   



Serial= 4101 WMO= 9999999

Return

←PreviousNext→

Cycle 6 GMT 23/ 2/2024 7:13: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 602 46 13.80 284 180 0.18 / 3.57 1 1
2 3 91.60 1810 -1 13.82 0 0 0.00 / 3.57 1 1
3 6 121.76 3419 -100 13.82 0 0 0.00 / 3.57 1 1
4 3 228.04 4039 44 13.80 284 172 0.35 / 3.74 1 1
5 6 165.00 6850 -100 13.80 279 0 0.17 / 3.74 1 1
6 7 297.12 7625 121 13.80 290 484 0.84 / 4.23 1 1
7 8 -0.40 9173 161 13.79 284 631 1.47 / 4.86 1 115
8 14 -1.40 9335 59 13.80 285 232 1.70 / 5.09 114 115
Average= 1.70
(KJ/cycle)

Cycle 5 GMT 23/ 2/2024 4:30: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 601 46 13.80 285 181 0.18 / 1.88 1 1
2 6 121.60 3415 -100 13.83 0 0 0.00 / 1.88 1 1
3 3 227.44 4035 44 13.80 284 172 0.35 / 2.05 1 1
4 6 165.12 6847 -100 13.80 280 0 0.17 / 2.05 1 1
5 7 297.40 7623 120 13.79 290 480 0.83 / 2.53 1 1
6 8 -0.76 9120 161 13.79 284 631 1.46 / 3.16 1 115
7 14 -0.76 9283 59 13.79 284 231 1.69 / 3.39 114 114
Average= 1.70
(KJ/cycle)

Cycle 4 GMT 23/ 2/2024 1:48: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 300 46 13.78 284 180 0.18 / 0.18 1 1
2 6 122.44 3415 -100 13.80 0 0 0.00 / 0.18 1 1
3 3 228.64 4035 44 13.79 284 172 0.35 / 0.35 1 1
4 6 197.00 6846 -100 13.80 280 0 0.17 / 0.35 1 1
5 7 298.08 7442 120 13.81 290 481 0.83 / 0.83 1 1
6 8 0.56 9005 161 13.80 284 631 1.46 / 1.46 1 114
7 14 -0.08 9167 59 13.80 285 232 1.70 / 1.70 115 115
Average= 1.70
(KJ/cycle)