SIO Argo Site:
Pump Diagnostics Page   



Serial= 3321 WMO= 7902208

Return

←PreviousNext→

Cycle 11 GMT 5/ 3/2025 20:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 30 15.15 492 224 0.22 / 38.67 2 5
2 3 1019.36 1 15.15 1755 27 0.25 / 38.70 2 2
3 7 2020.12 38 14.81 2959 1665 1.92 / 40.36 2 5
4 13 1404.60 18 14.90 2212 593 2.51 / 40.96 2 6
5 13 736.48 18 15.04 1316 356 2.86 / 41.31 2 10
6 13 235.72 18 15.17 672 183 3.05 / 41.50 2 11
7 8 0.24 165 15.20 314 788 3.84 / 42.28 2 21
Average= 3.52
(KJ/cycle)

Cycle 10 GMT 24/ 2/2025 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 30 15.15 505 230 0.23 / 34.82 2 3
2 7 2005.44 38 14.84 2968 1674 1.90 / 36.49 2 4
3 13 1417.64 18 14.94 2245 604 2.51 / 37.09 2 6
4 13 773.16 18 15.05 1397 378 2.89 / 37.47 2 8
5 13 233.40 18 15.19 672 184 3.07 / 37.66 2 11
6 8 0.12 165 15.22 315 791 3.86 / 38.45 2 22
Average= 3.50
(KJ/cycle)

Cycle 9 GMT 14/ 2/2025 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 29 15.16 503 221 0.22 / 30.96 2 3
2 3 1027.36 1 15.12 1776 27 0.25 / 30.99 2 2
3 7 2005.32 38 14.83 2973 1675 1.92 / 32.66 2 4
4 13 1370.64 18 14.93 2168 583 2.51 / 33.25 2 7
5 13 834.04 18 15.03 1465 396 2.90 / 33.64 2 10
6 13 174.20 18 15.21 590 162 3.06 / 33.80 2 13
7 8 -0.04 165 15.22 312 784 3.85 / 34.59 2 20
Average= 3.46
(KJ/cycle)

Cycle 8 GMT 4/ 2/2025 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 15.14 505 214 0.21 / 27.24 2 3
2 3 1039.48 1 15.09 1796 27 0.24 / 27.27 2 2
3 7 2005.96 38 14.86 2932 1656 1.90 / 28.92 2 4
4 13 1347.88 18 14.95 2139 576 2.47 / 29.50 2 6
5 13 778.40 18 15.06 1381 374 2.85 / 29.87 2 9
6 13 173.56 9 15.22 585 80 2.93 / 29.95 2 8
7 8 0.36 165 15.23 313 787 3.71 / 30.74 2 20
Average= 3.42
(KJ/cycle)

Cycle 7 GMT 25/ 1/2025 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 29 15.14 487 214 0.21 / 23.76 2 2
2 7 1815.88 38 14.89 2663 1507 1.72 / 25.27 2 3
3 13 1302.28 18 14.94 2069 556 2.28 / 25.82 2 7
4 13 713.92 18 15.05 1308 354 2.63 / 26.18 2 9
5 13 166.00 8 15.21 572 70 2.70 / 26.25 2 10
6 8 0.12 165 15.21 311 781 3.48 / 27.03 2 22
Average= 3.38
(KJ/cycle)

Cycle 6 GMT 24/ 1/2025 16:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 28 15.14 505 214 0.21 / 20.18 2 3
2 3 1029.52 1 15.18 1783 27 0.24 / 20.21 2 2
3 7 1821.40 39 14.90 2713 1577 1.82 / 21.79 2 4
4 13 1303.76 18 14.95 2074 558 2.38 / 22.34 2 6
5 13 715.32 18 15.06 1307 354 2.73 / 22.70 2 9
6 13 200.56 9 15.20 613 84 2.81 / 22.78 2 8
7 8 0.32 165 15.21 304 763 3.58 / 23.54 2 18
Average= 3.36
(KJ/cycle)

Cycle 5 GMT 23/ 1/2025 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 15.15 480 204 0.20 / 15.85 2 2
2 7 1824.44 74 14.77 2712 2964 3.17 / 18.81 2 8
3 13 438.32 18 15.12 943 257 3.42 / 19.07 2 12
4 13 45.76 5 15.26 366 28 3.45 / 19.10 2 8
5 13 16.88 18 15.24 343 94 3.55 / 19.19 2 10
6 8 0.00 165 15.20 310 777 4.32 / 19.97 2 16
Average= 3.33
(KJ/cycle)

Cycle 4 GMT 22/ 1/2025 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 15.17 485 206 0.21 / 12.16 2 3
2 7 1513.44 74 14.88 2334 2570 2.78 / 14.73 2 8
3 13 323.96 13 15.19 781 154 2.93 / 14.88 2 10
4 8 0.00 165 15.24 302 759 3.69 / 15.64 2 23
Average= 3.13
(KJ/cycle)

Cycle 3 GMT 21/ 1/2025 14:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 25 15.20 491 187 0.19 / 8.40 2 2
2 10 1031.60 3 15.09 1804 82 0.27 / 8.48 2 2
3 3 1044.24 1 15.18 1789 27 0.30 / 8.51 2 2
4 7 1510.04 74 14.89 2318 2554 2.85 / 11.06 2 9
5 13 231.80 10 15.23 652 99 2.95 / 11.16 2 9
6 13 55.16 5 15.28 398 30 2.98 / 11.19 2 8
7 8 0.08 165 15.25 304 765 3.74 / 11.95 2 16
Average= 2.99
(KJ/cycle)

Cycle 2 GMT 20/ 1/2025 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 31 15.24 495 234 0.23 / 4.76 2 3
2 3 884.60 -2 15.58 0 0 0.00 / 4.76 2 3
3 3 917.80 -2 15.60 0 0 0.00 / 4.76 2 3
4 7 1507.64 74 14.91 2304 2542 2.78 / 7.30 2 9
5 13 246.92 11 15.24 670 112 2.89 / 7.41 2 9
6 13 46.68 5 15.30 372 28 2.92 / 7.44 2 8
7 8 0.12 165 15.26 305 768 3.68 / 8.21 2 20
Average= 2.74
(KJ/cycle)

Cycle 1 GMT 19/ 1/2025 15:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 26 15.40 435 174 0.17 / 1.86 2 3
2 10 1028.92 2 15.20 1738 53 0.23 / 1.92 2 4
3 7 993.68 75 15.08 1641 1856 2.08 / 3.77 2 10
4 8 0.08 165 15.32 298 753 2.84 / 4.53 2 18
Average= 2.26
(KJ/cycle)

Cycle 0 GMT 19/ 1/2025 5:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 139.92 25 15.54 502 195 0.20 / 0.20 2 3
2 7 155.52 74 15.50 499 572 0.77 / 0.77 2 5
3 8 -0.20 225 15.46 265 922 1.69 / 1.69 2 135
Average= 1.69
(KJ/cycle)