Cycle 19 GMT 12/12/2024 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 32 15.20 464 226 0.23 / 69.72 2 3
2 7 2026.24 38 14.92 2893 1640 1.87 / 71.36 2 4
3 13 1322.32 18 14.99 2061 556 2.42 / 71.91 2 5
4 13 893.72 18 15.05 1523 413 2.83 / 72.33 2 6
5 13 128.64 18 15.24 506 139 2.97 / 72.47 2 6
6 8 0.08 165 15.23 319 802 3.78 / 73.27 2 14
Average= 3.66
(KJ/cycle)

Cycle 18 GMT 2/12/2024 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 32 15.18 479 233 0.23 / 65.90 2 2
2 7 2004.64 38 14.92 2866 1625 1.86 / 67.53 2 4
3 13 1467.12 18 14.98 2242 605 2.46 / 68.13 2 6
4 13 918.48 18 15.07 1546 419 2.88 / 68.55 2 6
5 13 161.92 18 15.24 542 149 3.03 / 68.70 2 4
6 8 0.12 165 15.24 314 790 3.82 / 69.49 2 16
Average= 3.66
(KJ/cycle)

Cycle 17 GMT 22/11/2024 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 15.18 469 228 0.23 / 62.11 2 2
2 7 1940.32 38 14.91 2798 1585 1.81 / 63.70 2 3
3 13 1431.08 18 14.97 2192 591 2.40 / 64.29 2 5
4 13 813.20 18 15.10 1419 386 2.79 / 64.67 2 5
5 13 250.76 18 15.21 676 185 2.97 / 64.86 2 5
6 8 0.00 165 15.23 324 814 3.79 / 65.67 2 18
Average= 3.65
(KJ/cycle)

Cycle 16 GMT 12/11/2024 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 32 15.20 470 229 0.23 / 58.37 2 3
2 7 1933.24 39 14.93 2791 1625 1.85 / 60.00 2 4
3 13 1335.08 18 15.02 2088 565 2.42 / 60.56 2 4
4 13 803.72 18 15.10 1412 384 2.80 / 60.95 2 6
5 13 83.64 18 15.27 446 123 2.92 / 61.07 2 5
6 8 0.20 165 15.24 324 815 3.74 / 61.88 2 16
Average= 3.64
(KJ/cycle)

Cycle 15 GMT 2/11/2024 16:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 31 15.21 477 225 0.22 / 54.76 2 2
2 10 1004.04 2 15.25 1682 51 0.28 / 54.81 2 3
3 3 958.64 -1 15.55 1 0 0.05 / 54.81 2 3
4 3 1017.16 1 15.30 1727 26 0.30 / 54.84 2 3
5 7 1651.64 39 15.04 2444 1434 1.74 / 56.27 2 3
6 13 1243.36 18 15.06 1959 531 2.27 / 56.80 2 4
7 13 804.04 18 15.12 1403 382 2.65 / 57.18 2 6
8 13 141.12 18 15.27 524 144 2.79 / 57.33 2 5
9 8 0.08 165 15.25 324 815 3.61 / 58.14 2 15
Average= 3.63
(KJ/cycle)

Cycle 14 GMT 23/10/2024 19:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 31 15.21 469 221 0.22 / 51.38 2 2
2 7 1508.68 38 15.11 2273 1305 1.53 / 52.68 2 3
3 13 1331.88 18 15.11 2080 566 2.09 / 53.25 2 6
4 13 692.60 18 15.20 1270 347 2.44 / 53.59 2 6
5 13 88.88 18 15.30 458 126 2.57 / 53.72 2 5
6 8 0.16 165 15.26 324 816 3.38 / 54.54 2 18
Average= 3.64
(KJ/cycle)

Cycle 13 GMT 13/10/2024 22:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 31 15.21 467 220 0.22 / 47.90 2 2
2 7 1642.64 39 15.06 2435 1430 1.65 / 49.33 2 3
3 13 1240.04 18 15.08 1968 534 2.18 / 49.87 2 5
4 13 668.52 18 15.18 1237 338 2.52 / 50.20 2 6
5 13 111.12 18 15.28 486 134 2.66 / 50.34 2 4
6 8 0.04 165 15.26 324 816 3.47 / 51.15 2 18
Average= 3.65
(KJ/cycle)

Cycle 12 GMT 4/10/2024 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 31 15.22 464 219 0.22 / 44.12 2 2
2 7 2006.44 38 14.96 2871 1632 1.85 / 45.75 2 3
3 13 1391.12 18 15.01 2157 583 2.43 / 46.33 2 4
4 13 802.44 18 15.13 1407 383 2.82 / 46.72 2 5
5 13 198.76 18 15.25 600 165 2.98 / 46.88 2 5
6 8 0.00 165 15.26 318 801 3.78 / 47.68 2 16
Average= 3.67
(KJ/cycle)

Cycle 11 GMT 24/ 9/2024 5:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 31 15.22 467 220 0.22 / 40.28 2 2
2 10 1007.44 2 15.28 1690 52 0.27 / 40.33 2 3
3 3 969.20 -1 15.57 1 0 0.05 / 40.33 2 3
4 3 1025.20 1 15.33 1703 26 0.30 / 40.35 2 3
5 7 1949.76 38 14.96 2802 1593 1.89 / 41.95 2 4
6 13 1286.16 18 15.05 2018 547 2.44 / 42.49 2 4
7 13 887.96 18 15.09 1516 412 2.85 / 42.90 2 6
8 13 271.24 18 15.23 701 192 3.04 / 43.10 2 4
9 8 0.16 165 15.26 319 803 3.84 / 43.90 2 17
Average= 3.66
(KJ/cycle)

Cycle 10 GMT 14/ 9/2024 7:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 30 15.22 463 211 0.21 / 36.54 2 2
2 10 1022.40 2 15.26 1736 53 0.26 / 36.59 2 3
3 3 961.52 -1 15.57 1 0 0.05 / 36.59 2 3
4 7 1923.52 38 14.97 2780 1581 1.85 / 38.17 2 4
5 13 1257.60 18 15.05 1981 537 2.38 / 38.71 2 5
6 13 781.04 18 15.14 1373 374 2.76 / 39.08 2 6
7 13 219.72 18 15.26 624 171 2.93 / 39.25 2 6
8 8 0.04 165 15.27 318 801 3.73 / 40.06 2 12
Average= 3.64
(KJ/cycle)

Cycle 9 GMT 4/ 9/2024 10: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 30 15.23 477 218 0.22 / 32.69 2 2
2 10 1012.00 2 15.28 1704 52 0.27 / 32.74 2 3
3 3 955.92 -1 15.57 1 0 0.05 / 32.74 2 3
4 7 2016.88 39 14.95 2887 1683 1.95 / 34.42 2 4
5 13 1294.08 18 15.05 2024 548 2.50 / 34.97 2 6
6 13 813.92 18 15.13 1421 387 2.89 / 35.36 2 6
7 13 147.36 18 15.27 534 147 3.04 / 35.51 2 5
8 8 0.04 165 15.27 325 819 3.85 / 36.33 2 16
Average= 3.63
(KJ/cycle)

Cycle 8 GMT 25/ 8/2024 15:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 30 15.23 470 215 0.21 / 28.21 2 2
2 7 2005.80 74 14.83 2856 3134 3.35 / 31.34 2 5
3 13 567.52 18 15.19 1095 299 3.65 / 31.64 2 7
4 8 0.12 165 15.27 329 829 4.48 / 32.47 2 17
Average= 3.61
(KJ/cycle)

Cycle 7 GMT 15/ 8/2024 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 30 15.24 480 219 0.22 / 24.12 2 2
2 7 1772.32 74 14.93 2575 2845 3.06 / 26.97 2 5
3 13 349.48 18 15.25 805 221 3.29 / 27.19 2 5
4 8 0.04 165 15.29 320 807 4.09 / 27.99 2 15
Average= 3.50
(KJ/cycle)

Cycle 6 GMT 14/ 8/2024 17:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 29 15.25 467 207 0.21 / 19.91 2 2
2 10 1004.56 2 15.29 1678 51 0.26 / 19.96 2 4
3 3 957.76 -1 15.62 0 0 0.05 / 19.96 2 4
4 7 1815.56 74 14.92 2618 2890 3.15 / 22.85 2 5
5 13 433.80 18 15.22 920 252 3.40 / 23.10 2 4
6 8 0.12 165 15.27 317 799 4.20 / 23.90 2 17
Average= 3.41
(KJ/cycle)

Cycle 5 GMT 13/ 8/2024 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 15.25 455 201 0.20 / 15.82 2 2
2 7 1806.24 74 14.91 2612 2882 3.08 / 18.70 2 5
3 13 299.32 18 15.27 733 201 3.28 / 18.91 2 4
4 8 0.16 165 15.28 316 797 4.08 / 19.70 2 12
Average= 3.28
(KJ/cycle)

Cycle 4 GMT 12/ 8/2024 16: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 29 15.24 463 205 0.20 / 12.10 2 2
2 10 1000.40 2 15.26 1688 52 0.26 / 12.15 2 3
3 3 945.76 -1 15.62 1 0 0.05 / 12.15 2 3
4 7 1527.00 74 15.03 2267 2521 2.78 / 14.67 2 4
5 13 213.00 18 15.29 603 166 2.94 / 14.84 2 4
6 8 0.04 165 15.29 310 782 3.73 / 15.62 2 13
Average= 3.12
(KJ/cycle)

Cycle 3 GMT 11/ 8/2024 16:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 29 15.23 473 209 0.21 / 8.41 2 2
2 7 1514.40 74 15.03 2259 2513 2.72 / 10.93 2 5
3 13 253.12 18 15.28 660 182 2.90 / 11.11 2 5
4 8 0.20 165 15.29 312 787 3.69 / 11.90 2 13
Average= 2.97
(KJ/cycle)

Cycle 2 GMT 10/ 8/2024 17:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 32 15.27 456 223 0.22 / 4.72 2 2
2 3 847.56 -3 15.63 1 0 0.00 / 4.72 2 2
3 7 1529.04 74 15.02 2272 2525 2.75 / 7.24 2 4
4 13 217.52 18 15.29 615 169 2.92 / 7.41 2 5
5 8 0.12 165 15.29 314 792 3.71 / 8.21 2 13
Average= 2.74
(KJ/cycle)

Cycle 1 GMT 9/ 8/2024 17:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 27 15.43 415 173 0.17 / 1.89 2 2
2 3 1019.60 1 15.35 1704 26 0.20 / 1.92 2 2
3 7 992.44 74 15.19 1600 1798 2.00 / 3.72 2 6
4 8 0.04 165 15.34 308 780 2.78 / 4.50 2 10
Average= 2.25
(KJ/cycle)

Cycle 0 GMT 9/ 8/2024 7: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.76 27 15.60 458 193 0.19 / 0.19 2 4
2 7 163.88 74 15.57 471 543 0.74 / 0.74 2 8
3 8 0.20 240 15.52 264 983 1.72 / 1.72 2 12
Average= 1.72
(KJ/cycle)