SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 29 | 15.13 | 558 | 245 | 0.24 / 298.72 | 2 | 27 |
2 | 7 | 2012.64 | 38 | 14.83 | 3003 | 1692 | 1.94 / 300.42 | 2 | 19 |
3 | 13 | 1261.36 | 18 | 14.94 | 2082 | 560 | 2.50 / 300.98 | 2 | 23 |
4 | 13 | 727.20 | 18 | 15.03 | 1402 | 379 | 2.88 / 301.36 | 2 | 27 |
5 | 13 | 75.92 | 6 | 15.24 | 508 | 46 | 2.92 / 301.40 | 2 | 25 |
6 | 13 | 58.28 | 5 | 15.24 | 497 | 38 | 2.96 / 301.44 | 2 | 22 |
7 | 8 | 0.20 | 165 | 15.20 | 392 | 983 | 3.94 / 302.42 | 2 | 17 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 27 | 15.15 | 532 | 218 | 0.22 / 294.65 | 2 | 26 |
2 | 10 | 1018.44 | 3 | 15.06 | 1855 | 84 | 0.30 / 294.73 | 2 | 21 |
3 | 7 | 2009.80 | 38 | 14.83 | 3014 | 1699 | 2.00 / 296.43 | 2 | 18 |
4 | 13 | 1299.16 | 18 | 14.96 | 2130 | 574 | 2.57 / 297.01 | 2 | 23 |
5 | 13 | 686.60 | 18 | 15.07 | 1352 | 367 | 2.94 / 297.37 | 2 | 27 |
6 | 13 | 66.12 | 18 | 15.26 | 483 | 133 | 3.07 / 297.50 | 2 | 25 |
7 | 8 | -0.04 | 165 | 15.22 | 388 | 974 | 4.05 / 298.48 | 2 | 22 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 30 | 15.10 | 541 | 245 | 0.25 / 290.86 | 2 | 27 |
2 | 3 | 950.24 | -2 | 15.54 | 1 | 0 | 0.00 / 290.86 | 2 | 27 |
3 | 7 | 1806.68 | 38 | 14.88 | 2768 | 1565 | 1.81 / 292.42 | 2 | 20 |
4 | 13 | 1236.92 | 18 | 15.00 | 2059 | 556 | 2.37 / 292.98 | 2 | 23 |
5 | 13 | 608.00 | 18 | 15.12 | 1242 | 338 | 2.70 / 293.32 | 2 | 28 |
6 | 13 | 46.64 | 18 | 15.27 | 463 | 127 | 2.83 / 293.45 | 2 | 21 |
7 | 8 | 0.28 | 165 | 15.22 | 393 | 987 | 3.82 / 294.43 | 2 | 20 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 29 | 15.05 | 562 | 245 | 0.25 / 286.99 | 2 | 27 |
2 | 3 | 1019.60 | 1 | 15.17 | 1849 | 28 | 0.27 / 287.02 | 2 | 4 |
3 | 7 | 1812.88 | 38 | 14.88 | 2770 | 1566 | 1.84 / 288.59 | 2 | 19 |
4 | 13 | 1206.20 | 18 | 14.99 | 2007 | 542 | 2.38 / 289.13 | 2 | 23 |
5 | 13 | 711.36 | 18 | 15.07 | 1375 | 373 | 2.75 / 289.50 | 2 | 27 |
6 | 13 | 50.08 | 18 | 15.25 | 473 | 130 | 2.88 / 289.63 | 2 | 22 |
7 | 8 | 0.08 | 165 | 15.21 | 392 | 984 | 3.87 / 290.61 | 2 | 18 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 7 | 15.15 | 573 | 61 | 0.06 / 282.21 | 2 | 24 |
2 | 10 | 1048.72 | 7 | 14.96 | 1893 | 198 | 0.26 / 282.41 | 2 | 21 |
3 | 10 | 1136.24 | 5 | 14.94 | 2016 | 151 | 0.41 / 282.56 | 2 | 21 |
4 | 10 | 1193.76 | 4 | 14.95 | 2088 | 125 | 0.53 / 282.68 | 2 | 21 |
5 | 3 | 1251.28 | 7 | 14.95 | 2183 | 228 | 0.76 / 282.91 | 2 | 21 |
6 | 3 | 1021.12 | 1 | 15.13 | 1824 | 28 | 0.79 / 282.94 | 2 | 6 |
7 | 7 | 2010.08 | 38 | 14.85 | 3004 | 1695 | 2.49 / 284.63 | 2 | 18 |
8 | 13 | 1352.60 | 18 | 14.94 | 2207 | 594 | 3.08 / 285.23 | 2 | 23 |
9 | 13 | 760.20 | 18 | 15.06 | 1441 | 391 | 3.47 / 285.62 | 2 | 26 |
10 | 13 | 107.12 | 18 | 15.23 | 548 | 150 | 3.62 / 285.77 | 2 | 27 |
11 | 8 | 0.16 | 165 | 15.21 | 390 | 979 | 4.60 / 286.75 | 2 | 22 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 7 | 15.22 | 577 | 61 | 0.06 / 278.38 | 2 | 25 |
2 | 3 | 1030.48 | 1 | 15.13 | 1881 | 28 | 0.09 / 278.41 | 2 | 11 |
3 | 7 | 2008.00 | 38 | 14.84 | 3003 | 1693 | 1.78 / 280.10 | 2 | 19 |
4 | 13 | 1301.88 | 18 | 14.95 | 2145 | 577 | 2.36 / 280.68 | 2 | 23 |
5 | 13 | 723.60 | 18 | 15.07 | 1398 | 379 | 2.74 / 281.06 | 2 | 27 |
6 | 13 | 70.40 | 6 | 15.28 | 481 | 44 | 2.78 / 281.10 | 2 | 24 |
7 | 13 | 54.96 | 5 | 15.27 | 481 | 37 | 2.82 / 281.14 | 2 | 22 |
8 | 8 | 0.16 | 165 | 15.21 | 401 | 1006 | 3.83 / 282.15 | 2 | 18 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 7 | 15.26 | 558 | 60 | 0.06 / 275.62 | 2 | 25 |
2 | 7 | 2008.24 | 38 | 14.83 | 3000 | 1691 | 1.75 / 277.31 | 2 | 18 |
3 | 13 | 1280.76 | 18 | 14.95 | 2118 | 570 | 2.32 / 277.88 | 2 | 23 |
4 | 13 | 686.08 | 18 | 15.08 | 1350 | 366 | 2.69 / 278.25 | 2 | 27 |
5 | 13 | 59.00 | 5 | 15.27 | 485 | 37 | 2.72 / 278.28 | 2 | 23 |
6 | 13 | 44.52 | 5 | 15.25 | 471 | 36 | 2.76 / 278.32 | 2 | 20 |
Average= | 3.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 5 | 15.24 | 571 | 44 | 0.04 / 272.77 | 2 | 24 |
2 | 10 | 1000.72 | 2 | 15.08 | 1855 | 56 | 0.10 / 272.82 | 2 | 22 |
3 | 7 | 2009.84 | 38 | 14.83 | 3015 | 1699 | 1.80 / 274.52 | 2 | 18 |
4 | 13 | 1310.48 | 18 | 14.95 | 2155 | 580 | 2.38 / 275.10 | 2 | 23 |
5 | 13 | 721.80 | 18 | 15.07 | 1397 | 379 | 2.76 / 275.48 | 2 | 27 |
6 | 13 | 69.60 | 6 | 15.26 | 494 | 45 | 2.80 / 275.53 | 2 | 24 |
7 | 13 | 46.72 | 5 | 15.27 | 462 | 35 | 2.84 / 275.56 | 2 | 20 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 6 | 15.26 | 572 | 52 | 0.05 / 270.00 | 2 | 25 |
2 | 3 | 947.84 | -2 | 15.54 | 1 | 0 | 0.00 / 270.00 | 2 | 25 |
3 | 7 | 2007.16 | 38 | 14.83 | 3007 | 1695 | 1.75 / 271.70 | 2 | 18 |
4 | 13 | 1311.16 | 18 | 14.94 | 2147 | 577 | 2.32 / 272.27 | 2 | 23 |
5 | 13 | 682.36 | 18 | 15.07 | 1349 | 366 | 2.69 / 272.64 | 2 | 27 |
6 | 13 | 76.80 | 6 | 15.26 | 512 | 47 | 2.74 / 272.69 | 2 | 24 |
7 | 13 | 48.16 | 5 | 15.27 | 486 | 37 | 2.77 / 272.72 | 2 | 20 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 6 | 15.27 | 563 | 52 | 0.05 / 267.20 | 2 | 25 |
2 | 10 | 1024.00 | 2 | 15.11 | 1865 | 56 | 0.11 / 267.26 | 2 | 20 |
3 | 3 | 982.52 | -1 | 15.52 | 1 | 0 | 0.06 / 267.26 | 2 | 20 |
4 | 7 | 1968.08 | 38 | 14.85 | 2958 | 1669 | 1.78 / 268.93 | 2 | 19 |
5 | 13 | 1452.48 | 18 | 14.93 | 2330 | 626 | 2.40 / 269.55 | 2 | 23 |
6 | 13 | 632.80 | 18 | 15.09 | 1286 | 349 | 2.75 / 269.90 | 2 | 27 |
7 | 13 | 64.96 | 6 | 15.28 | 490 | 45 | 2.80 / 269.95 | 2 | 23 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 6 | 15.27 | 572 | 52 | 0.05 / 264.46 | 2 | 25 |
2 | 7 | 2002.16 | 38 | 14.84 | 2996 | 1690 | 1.74 / 266.15 | 2 | 19 |
3 | 13 | 1303.96 | 18 | 14.97 | 2152 | 580 | 2.32 / 266.73 | 2 | 23 |
4 | 13 | 693.40 | 18 | 15.09 | 1370 | 372 | 2.69 / 267.10 | 2 | 27 |
5 | 13 | 72.00 | 6 | 15.28 | 501 | 46 | 2.74 / 267.15 | 2 | 24 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 6 | 15.26 | 572 | 52 | 0.05 / 261.69 | 2 | 25 |
2 | 3 | 959.84 | -1 | 15.53 | 1 | 0 | 0.00 / 261.69 | 2 | 25 |
3 | 7 | 2008.16 | 38 | 14.85 | 3018 | 1703 | 1.76 / 263.39 | 2 | 19 |
4 | 13 | 1316.72 | 18 | 14.97 | 2178 | 587 | 2.34 / 263.98 | 2 | 23 |
5 | 13 | 719.56 | 18 | 15.08 | 1411 | 383 | 2.73 / 264.36 | 2 | 27 |
6 | 13 | 74.24 | 6 | 15.29 | 505 | 46 | 2.77 / 264.41 | 2 | 24 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 11 | 15.24 | 585 | 98 | 0.10 / 258.92 | 2 | 25 |
2 | 3 | 790.64 | -7 | 15.52 | 1 | 0 | 0.00 / 258.92 | 2 | 25 |
3 | 3 | 984.92 | -1 | 15.56 | 0 | 0 | 0.00 / 258.92 | 2 | 25 |
4 | 7 | 2009.44 | 38 | 14.84 | 3024 | 1705 | 1.80 / 260.62 | 2 | 18 |
5 | 13 | 1311.20 | 18 | 14.96 | 2163 | 582 | 2.39 / 261.21 | 2 | 23 |
6 | 13 | 738.40 | 18 | 15.08 | 1428 | 388 | 2.77 / 261.59 | 2 | 27 |
7 | 13 | 78.56 | 6 | 15.28 | 509 | 47 | 2.82 / 261.64 | 2 | 25 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 8 | 15.32 | 589 | 72 | 0.07 / 255.97 | 2 | 25 |
2 | 10 | 1059.52 | 4 | 15.10 | 1912 | 115 | 0.19 / 256.09 | 2 | 23 |
3 | 7 | 2012.96 | 39 | 14.83 | 3015 | 1744 | 1.93 / 257.83 | 2 | 18 |
4 | 13 | 1266.84 | 18 | 14.98 | 2109 | 569 | 2.50 / 258.40 | 2 | 23 |
5 | 13 | 687.16 | 18 | 15.09 | 1366 | 371 | 2.87 / 258.77 | 2 | 27 |
6 | 13 | 71.52 | 6 | 15.27 | 515 | 47 | 2.92 / 258.82 | 2 | 25 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 5 | 15.27 | 582 | 44 | 0.04 / 253.77 | 2 | 25 |
2 | 10 | 1027.40 | 3 | 15.10 | 1886 | 85 | 0.13 / 253.86 | 2 | 22 |
3 | 3 | 1027.80 | 1 | 15.15 | 1886 | 29 | 0.16 / 253.89 | 2 | 10 |
4 | 7 | 1186.60 | 38 | 15.15 | 1993 | 1147 | 1.31 / 255.03 | 2 | 24 |
5 | 13 | 1153.12 | 18 | 15.12 | 1965 | 535 | 1.84 / 255.57 | 2 | 25 |
6 | 13 | 572.92 | 18 | 15.21 | 1210 | 331 | 2.17 / 255.90 | 2 | 28 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 6 | 15.26 | 583 | 53 | 0.05 / 251.01 | 2 | 25 |
2 | 3 | 964.96 | -1 | 15.52 | 1 | 0 | 0.00 / 251.01 | 2 | 25 |
3 | 7 | 2008.08 | 38 | 14.85 | 3029 | 1709 | 1.76 / 252.72 | 2 | 18 |
4 | 13 | 1303.32 | 18 | 14.96 | 2155 | 580 | 2.34 / 253.30 | 2 | 23 |
5 | 13 | 717.96 | 18 | 15.10 | 1401 | 381 | 2.72 / 253.68 | 2 | 27 |
6 | 13 | 77.92 | 6 | 15.27 | 524 | 48 | 2.77 / 253.73 | 2 | 25 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 6 | 15.25 | 573 | 52 | 0.05 / 248.22 | 2 | 25 |
2 | 7 | 2010.28 | 38 | 14.85 | 3023 | 1706 | 1.76 / 249.93 | 2 | 19 |
3 | 13 | 1311.84 | 18 | 14.97 | 2163 | 583 | 2.34 / 250.51 | 2 | 23 |
4 | 13 | 765.40 | 18 | 15.08 | 1473 | 400 | 2.74 / 250.91 | 2 | 27 |
5 | 13 | 67.64 | 6 | 15.27 | 508 | 47 | 2.79 / 250.96 | 2 | 24 |
Average= | 3.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 8 | 15.27 | 564 | 69 | 0.07 / 245.40 | 2 | 25 |
2 | 3 | 911.84 | -3 | 15.53 | 1 | 0 | 0.00 / 245.40 | 2 | 25 |
3 | 7 | 2008.36 | 38 | 14.85 | 3011 | 1699 | 1.77 / 247.10 | 2 | 18 |
4 | 13 | 1313.88 | 18 | 14.98 | 2166 | 584 | 2.35 / 247.68 | 2 | 23 |
5 | 13 | 774.24 | 18 | 15.07 | 1479 | 401 | 2.75 / 248.08 | 2 | 27 |
6 | 13 | 79.04 | 6 | 15.28 | 535 | 49 | 2.80 / 248.13 | 2 | 25 |
7 | 13 | 59.12 | 5 | 15.28 | 504 | 39 | 2.84 / 248.17 | 2 | 23 |
Average= | 3.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 6 | 15.27 | 601 | 55 | 0.06 / 242.52 | 2 | 25 |
2 | 10 | 1026.60 | 3 | 15.12 | 1885 | 86 | 0.14 / 242.61 | 2 | 23 |
3 | 3 | 1016.16 | 1 | 15.18 | 1872 | 28 | 0.17 / 242.64 | 2 | 5 |
4 | 7 | 2007.12 | 38 | 14.85 | 3013 | 1700 | 1.87 / 244.34 | 2 | 18 |
5 | 13 | 1300.16 | 18 | 14.97 | 2149 | 579 | 2.45 / 244.92 | 2 | 23 |
6 | 13 | 674.04 | 18 | 15.10 | 1347 | 366 | 2.81 / 245.28 | 2 | 27 |
7 | 13 | 71.68 | 6 | 15.30 | 519 | 48 | 2.86 / 245.33 | 2 | 25 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 6 | 15.26 | 583 | 53 | 0.05 / 239.77 | 2 | 25 |
2 | 7 | 2005.60 | 38 | 14.86 | 3023 | 1707 | 1.76 / 241.47 | 2 | 18 |
3 | 13 | 1304.72 | 18 | 14.98 | 2159 | 582 | 2.34 / 242.06 | 2 | 23 |
4 | 13 | 659.92 | 18 | 15.12 | 1330 | 362 | 2.70 / 242.42 | 2 | 27 |
5 | 13 | 72.92 | 6 | 15.31 | 527 | 48 | 2.75 / 242.47 | 2 | 25 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 6 | 15.29 | 572 | 52 | 0.05 / 237.03 | 2 | 25 |
2 | 7 | 2007.04 | 38 | 14.84 | 3012 | 1699 | 1.75 / 238.73 | 2 | 18 |
3 | 13 | 1304.04 | 18 | 14.98 | 2160 | 582 | 2.33 / 239.31 | 2 | 23 |
4 | 13 | 678.76 | 18 | 15.11 | 1359 | 370 | 2.70 / 239.68 | 2 | 27 |
5 | 13 | 55.72 | 5 | 15.31 | 482 | 37 | 2.74 / 239.71 | 2 | 22 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 7 | 15.28 | 592 | 63 | 0.06 / 234.23 | 2 | 25 |
2 | 3 | 921.04 | -3 | 15.53 | 1 | 0 | 0.00 / 234.23 | 2 | 25 |
3 | 7 | 2010.00 | 38 | 14.85 | 3030 | 1710 | 1.77 / 235.94 | 2 | 18 |
4 | 13 | 1363.80 | 18 | 14.97 | 2240 | 604 | 2.38 / 236.54 | 2 | 22 |
5 | 13 | 717.60 | 18 | 15.09 | 1417 | 385 | 2.76 / 236.93 | 2 | 27 |
6 | 13 | 75.24 | 6 | 15.29 | 517 | 47 | 2.81 / 236.97 | 2 | 25 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 6 | 15.27 | 605 | 55 | 0.06 / 231.41 | 2 | 26 |
2 | 10 | 1007.84 | 2 | 15.13 | 1844 | 56 | 0.11 / 231.46 | 2 | 20 |
3 | 7 | 2012.40 | 38 | 14.86 | 3014 | 1702 | 1.81 / 233.17 | 2 | 18 |
4 | 13 | 1302.08 | 18 | 14.99 | 2162 | 583 | 2.40 / 233.75 | 2 | 23 |
5 | 13 | 678.08 | 18 | 15.11 | 1351 | 367 | 2.76 / 234.12 | 2 | 27 |
6 | 13 | 74.28 | 6 | 15.29 | 524 | 48 | 2.81 / 234.17 | 2 | 25 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 6 | 15.27 | 604 | 55 | 0.06 / 228.57 | 2 | 25 |
2 | 7 | 2009.04 | 38 | 14.86 | 3033 | 1713 | 1.77 / 230.28 | 2 | 18 |
3 | 13 | 1342.76 | 18 | 14.97 | 2216 | 597 | 2.37 / 230.88 | 2 | 23 |
4 | 13 | 718.12 | 18 | 15.10 | 1416 | 385 | 2.75 / 231.27 | 2 | 27 |
5 | 13 | 80.68 | 6 | 15.29 | 529 | 49 | 2.80 / 231.31 | 2 | 25 |
6 | 13 | 59.88 | 5 | 15.29 | 516 | 39 | 2.84 / 231.35 | 2 | 23 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 6 | 15.29 | 583 | 53 | 0.05 / 225.81 | 2 | 25 |
2 | 7 | 2007.32 | 38 | 14.85 | 3024 | 1706 | 1.76 / 227.52 | 2 | 18 |
3 | 13 | 1258.28 | 18 | 15.00 | 2100 | 567 | 2.33 / 228.08 | 2 | 23 |
4 | 13 | 718.72 | 18 | 15.09 | 1408 | 382 | 2.71 / 228.47 | 2 | 27 |
5 | 13 | 74.72 | 6 | 15.29 | 519 | 48 | 2.76 / 228.52 | 2 | 25 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 7 | 15.29 | 577 | 62 | 0.06 / 223.01 | 2 | 25 |
2 | 3 | 968.32 | -1 | 15.54 | 1 | 0 | 0.00 / 223.01 | 2 | 25 |
3 | 7 | 2004.48 | 39 | 14.86 | 3015 | 1747 | 1.81 / 224.76 | 2 | 18 |
4 | 13 | 1309.16 | 18 | 14.99 | 2166 | 584 | 2.39 / 225.34 | 2 | 23 |
5 | 13 | 670.60 | 18 | 15.12 | 1352 | 368 | 2.76 / 225.71 | 2 | 27 |
6 | 13 | 67.72 | 6 | 15.29 | 515 | 47 | 2.81 / 225.76 | 2 | 24 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 7 | 15.29 | 580 | 62 | 0.06 / 220.24 | 2 | 25 |
2 | 7 | 2010.00 | 38 | 14.86 | 3014 | 1702 | 1.76 / 221.94 | 2 | 18 |
3 | 13 | 1316.96 | 18 | 14.98 | 2170 | 585 | 2.35 / 222.53 | 2 | 23 |
4 | 13 | 686.12 | 18 | 15.11 | 1369 | 372 | 2.72 / 222.90 | 2 | 27 |
5 | 13 | 61.80 | 6 | 15.30 | 511 | 47 | 2.77 / 222.95 | 2 | 24 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 8 | 15.27 | 567 | 69 | 0.07 / 217.45 | 2 | 25 |
2 | 3 | 945.96 | -2 | 15.54 | 0 | 0 | 0.00 / 217.45 | 2 | 25 |
3 | 7 | 2010.24 | 38 | 14.86 | 3016 | 1703 | 1.77 / 219.16 | 2 | 18 |
4 | 13 | 1314.76 | 18 | 14.99 | 2170 | 586 | 2.36 / 219.74 | 2 | 23 |
5 | 13 | 735.12 | 18 | 15.10 | 1428 | 388 | 2.75 / 220.13 | 2 | 27 |
6 | 13 | 85.36 | 6 | 15.28 | 540 | 50 | 2.80 / 220.18 | 2 | 26 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 7 | 15.29 | 601 | 64 | 0.06 / 214.63 | 2 | 25 |
2 | 10 | 1008.96 | 2 | 15.15 | 1867 | 57 | 0.12 / 214.69 | 2 | 20 |
3 | 7 | 2007.00 | 38 | 14.87 | 3015 | 1704 | 1.82 / 216.39 | 2 | 18 |
4 | 13 | 1269.28 | 18 | 14.99 | 2118 | 571 | 2.40 / 216.97 | 2 | 23 |
5 | 13 | 692.16 | 18 | 15.11 | 1371 | 373 | 2.77 / 217.34 | 2 | 27 |
6 | 13 | 75.04 | 6 | 15.29 | 512 | 47 | 2.82 / 217.39 | 2 | 25 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 7 | 15.30 | 591 | 63 | 0.06 / 211.85 | 2 | 25 |
2 | 3 | 979.96 | -1 | 15.55 | 1 | 0 | 0.00 / 211.85 | 2 | 25 |
3 | 7 | 2010.52 | 38 | 14.87 | 3029 | 1712 | 1.77 / 213.56 | 2 | 19 |
4 | 13 | 1313.84 | 18 | 15.00 | 2169 | 586 | 2.36 / 214.15 | 2 | 23 |
5 | 13 | 721.64 | 18 | 15.12 | 1416 | 385 | 2.75 / 214.53 | 2 | 27 |
6 | 13 | 55.12 | 5 | 15.32 | 486 | 37 | 2.78 / 214.57 | 2 | 23 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 8 | 15.29 | 579 | 71 | 0.07 / 209.08 | 2 | 25 |
2 | 3 | 971.08 | -1 | 15.55 | 1 | 0 | 0.00 / 209.08 | 2 | 25 |
3 | 7 | 2010.32 | 38 | 14.87 | 3031 | 1713 | 1.78 / 210.79 | 2 | 18 |
4 | 13 | 1329.96 | 18 | 15.01 | 2188 | 591 | 2.37 / 211.38 | 2 | 23 |
5 | 13 | 652.68 | 18 | 15.13 | 1316 | 358 | 2.73 / 211.74 | 2 | 27 |
6 | 13 | 64.80 | 6 | 15.31 | 502 | 46 | 2.78 / 211.79 | 2 | 24 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 9 | 15.28 | 582 | 80 | 0.08 / 206.32 | 2 | 25 |
2 | 3 | 950.40 | -2 | 15.56 | 1 | 0 | 0.00 / 206.32 | 2 | 25 |
3 | 7 | 2007.80 | 38 | 14.87 | 3014 | 1703 | 1.78 / 208.02 | 2 | 19 |
4 | 13 | 1258.88 | 18 | 15.01 | 2100 | 567 | 2.35 / 208.59 | 2 | 23 |
5 | 13 | 680.04 | 18 | 15.12 | 1362 | 371 | 2.72 / 208.96 | 2 | 27 |
6 | 13 | 72.84 | 6 | 15.29 | 517 | 47 | 2.77 / 209.01 | 2 | 25 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 30 | 15.26 | 576 | 264 | 0.26 / 203.52 | 2 | 26 |
2 | 3 | 356.60 | -23 | 15.56 | 0 | 0 | 0.00 / 203.52 | 2 | 26 |
3 | 3 | 735.08 | -9 | 15.57 | 1 | 0 | 0.00 / 203.52 | 2 | 26 |
4 | 7 | 2012.32 | 38 | 14.88 | 3024 | 1710 | 1.97 / 205.23 | 2 | 18 |
5 | 13 | 1311.48 | 18 | 15.00 | 2170 | 586 | 2.56 / 205.82 | 2 | 23 |
6 | 13 | 680.68 | 18 | 15.13 | 1357 | 370 | 2.93 / 206.19 | 2 | 27 |
7 | 13 | 80.24 | 6 | 15.31 | 526 | 48 | 2.98 / 206.24 | 2 | 25 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 30 | 15.18 | 575 | 262 | 0.26 / 200.51 | 2 | 29 |
2 | 3 | 941.84 | -2 | 15.53 | 1 | 0 | 0.00 / 200.51 | 2 | 29 |
3 | 7 | 2006.48 | 38 | 14.88 | 3017 | 1706 | 1.97 / 202.21 | 2 | 18 |
4 | 13 | 1314.68 | 18 | 15.01 | 2179 | 589 | 2.56 / 202.80 | 2 | 23 |
5 | 13 | 676.56 | 18 | 15.13 | 1358 | 370 | 2.93 / 203.17 | 2 | 27 |
6 | 13 | 87.00 | 6 | 15.31 | 550 | 51 | 2.98 / 203.22 | 2 | 26 |
7 | 13 | 51.32 | 5 | 15.34 | 488 | 37 | 3.01 / 203.26 | 2 | 22 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 29 | 15.18 | 562 | 247 | 0.25 / 196.38 | 2 | 27 |
2 | 10 | 1011.32 | 3 | 15.10 | 1856 | 84 | 0.33 / 196.46 | 2 | 23 |
3 | 3 | 970.44 | -1 | 15.54 | 1 | 0 | 0.08 / 196.46 | 2 | 23 |
4 | 7 | 2009.28 | 38 | 14.88 | 3014 | 1704 | 2.04 / 198.16 | 2 | 18 |
5 | 13 | 1270.48 | 18 | 15.01 | 2111 | 570 | 2.61 / 198.74 | 2 | 23 |
6 | 13 | 777.00 | 18 | 15.11 | 1477 | 402 | 3.01 / 199.14 | 2 | 27 |
7 | 13 | 68.52 | 6 | 15.32 | 509 | 47 | 3.05 / 199.18 | 2 | 24 |
8 | 13 | 54.44 | 5 | 15.32 | 494 | 38 | 3.09 / 199.22 | 2 | 23 |
9 | 8 | 0.44 | 165 | 15.27 | 407 | 1025 | 4.12 / 200.25 | 2 | 18 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 29 | 15.18 | 589 | 259 | 0.26 / 192.13 | 2 | 28 |
2 | 7 | 2004.56 | 38 | 14.89 | 3018 | 1708 | 1.97 / 193.84 | 2 | 18 |
3 | 13 | 1497.08 | 18 | 14.97 | 2419 | 652 | 2.62 / 194.49 | 2 | 22 |
4 | 13 | 965.08 | 18 | 15.07 | 1725 | 468 | 3.09 / 194.96 | 2 | 26 |
5 | 13 | 191.00 | 9 | 15.27 | 702 | 96 | 3.18 / 195.05 | 2 | 30 |
6 | 13 | 65.76 | 6 | 15.31 | 517 | 47 | 3.23 / 195.10 | 2 | 24 |
7 | 8 | 0.12 | 165 | 15.26 | 409 | 1030 | 4.26 / 196.13 | 2 | 19 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 29 | 15.19 | 597 | 263 | 0.26 / 188.10 | 2 | 28 |
2 | 7 | 2008.00 | 39 | 14.89 | 3014 | 1750 | 2.01 / 189.85 | 2 | 18 |
3 | 13 | 1294.80 | 18 | 15.01 | 2145 | 580 | 2.59 / 190.43 | 2 | 23 |
4 | 13 | 619.16 | 18 | 15.16 | 1278 | 349 | 2.94 / 190.78 | 2 | 27 |
5 | 13 | 67.40 | 6 | 15.31 | 525 | 48 | 2.99 / 190.83 | 2 | 24 |
6 | 8 | 0.08 | 165 | 15.27 | 414 | 1043 | 4.03 / 191.87 | 2 | 20 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 29 | 15.19 | 597 | 263 | 0.26 / 183.95 | 2 | 28 |
2 | 3 | 1019.48 | 1 | 15.19 | 1852 | 28 | 0.29 / 183.98 | 2 | 7 |
3 | 7 | 2007.52 | 38 | 14.90 | 3017 | 1708 | 2.00 / 185.69 | 2 | 18 |
4 | 13 | 1316.44 | 18 | 15.01 | 2172 | 587 | 2.59 / 186.27 | 2 | 23 |
5 | 13 | 786.52 | 18 | 15.11 | 1499 | 408 | 2.99 / 186.68 | 2 | 27 |
6 | 13 | 78.20 | 6 | 15.32 | 542 | 50 | 3.04 / 186.73 | 2 | 25 |
7 | 13 | 49.00 | 5 | 15.33 | 497 | 38 | 3.08 / 186.77 | 2 | 21 |
8 | 8 | 0.24 | 165 | 15.27 | 423 | 1066 | 4.15 / 187.84 | 2 | 17 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 29 | 15.19 | 595 | 262 | 0.26 / 179.89 | 2 | 28 |
2 | 7 | 2008.44 | 39 | 14.88 | 3014 | 1749 | 2.01 / 181.64 | 2 | 18 |
3 | 13 | 1272.64 | 18 | 15.01 | 2118 | 572 | 2.58 / 182.21 | 2 | 24 |
4 | 13 | 681.68 | 18 | 15.14 | 1366 | 372 | 2.96 / 182.59 | 2 | 27 |
5 | 13 | 77.96 | 6 | 15.32 | 532 | 49 | 3.00 / 182.64 | 2 | 25 |
6 | 8 | 0.72 | 165 | 15.27 | 418 | 1053 | 4.06 / 183.69 | 2 | 17 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 27 | 15.19 | 595 | 244 | 0.24 / 175.79 | 2 | 28 |
2 | 10 | 1033.72 | 2 | 15.12 | 1867 | 56 | 0.30 / 175.85 | 2 | 22 |
3 | 7 | 2008.56 | 38 | 14.89 | 3017 | 1707 | 2.01 / 177.56 | 2 | 18 |
4 | 13 | 1249.12 | 18 | 15.03 | 2094 | 567 | 2.57 / 178.12 | 2 | 23 |
5 | 13 | 665.04 | 18 | 15.15 | 1347 | 367 | 2.94 / 178.49 | 2 | 27 |
6 | 13 | 69.16 | 6 | 15.32 | 519 | 48 | 2.99 / 178.54 | 2 | 24 |
7 | 13 | 54.44 | 5 | 15.33 | 505 | 39 | 3.03 / 178.58 | 2 | 23 |
8 | 8 | 0.12 | 165 | 15.27 | 418 | 1053 | 4.08 / 179.63 | 2 | 22 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 11 | 15.18 | 572 | 96 | 0.10 / 171.08 | 2 | 26 |
2 | 10 | 1011.40 | 7 | 15.02 | 1860 | 196 | 0.29 / 171.28 | 2 | 22 |
3 | 10 | 1090.04 | 5 | 14.99 | 1961 | 147 | 0.44 / 171.43 | 2 | 22 |
4 | 10 | 1137.08 | 3 | 14.99 | 2026 | 91 | 0.53 / 171.52 | 2 | 22 |
5 | 3 | 1175.72 | 5 | 15.03 | 2077 | 156 | 0.69 / 171.67 | 2 | 22 |
6 | 7 | 2007.36 | 38 | 14.89 | 3020 | 1709 | 2.39 / 173.38 | 2 | 18 |
7 | 13 | 1349.52 | 18 | 15.00 | 2210 | 597 | 2.99 / 173.98 | 2 | 22 |
8 | 13 | 725.20 | 18 | 15.14 | 1417 | 386 | 3.38 / 174.36 | 2 | 26 |
9 | 13 | 61.28 | 18 | 15.31 | 516 | 142 | 3.52 / 174.51 | 2 | 24 |
10 | 8 | -0.28 | 165 | 15.27 | 414 | 1043 | 4.56 / 175.55 | 2 | 21 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 30 | 15.15 | 591 | 269 | 0.27 / 167.31 | 2 | 28 |
2 | 3 | 964.36 | -1 | 15.58 | 1 | 0 | 0.00 / 167.31 | 2 | 28 |
3 | 7 | 1770.80 | 38 | 14.92 | 2725 | 1545 | 1.81 / 168.85 | 2 | 19 |
4 | 13 | 1306.84 | 18 | 15.00 | 2175 | 587 | 2.40 / 169.44 | 2 | 23 |
5 | 13 | 629.16 | 18 | 15.13 | 1296 | 353 | 2.75 / 169.79 | 2 | 27 |
6 | 13 | 64.60 | 18 | 15.29 | 508 | 140 | 2.89 / 169.93 | 2 | 24 |
7 | 8 | 0.12 | 165 | 15.24 | 419 | 1054 | 3.95 / 170.99 | 2 | 21 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 28 | 15.07 | 606 | 256 | 0.26 / 163.30 | 2 | 27 |
2 | 10 | 1031.92 | 2 | 15.05 | 1883 | 57 | 0.31 / 163.36 | 2 | 22 |
3 | 3 | 1020.20 | 1 | 15.18 | 1846 | 28 | 0.34 / 163.39 | 2 | 10 |
4 | 7 | 1778.80 | 38 | 14.91 | 2745 | 1555 | 1.90 / 164.94 | 2 | 19 |
5 | 13 | 1217.92 | 18 | 15.01 | 2046 | 553 | 2.45 / 165.49 | 2 | 23 |
6 | 13 | 689.44 | 18 | 15.11 | 1376 | 374 | 2.82 / 165.87 | 2 | 27 |
7 | 13 | 40.44 | 18 | 15.29 | 474 | 130 | 2.95 / 166.00 | 2 | 20 |
8 | 8 | 0.12 | 165 | 15.24 | 414 | 1041 | 3.99 / 167.04 | 2 | 18 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 26 | 15.17 | 599 | 236 | 0.24 / 159.27 | 2 | 28 |
2 | 10 | 1009.96 | 3 | 15.10 | 1852 | 84 | 0.32 / 159.35 | 2 | 23 |
3 | 7 | 1805.76 | 38 | 14.91 | 2773 | 1571 | 1.89 / 160.92 | 2 | 19 |
4 | 13 | 1279.56 | 18 | 14.99 | 2131 | 575 | 2.47 / 161.50 | 2 | 23 |
5 | 13 | 643.96 | 18 | 15.12 | 1324 | 360 | 2.83 / 161.86 | 2 | 27 |
6 | 13 | 44.88 | 18 | 15.29 | 482 | 133 | 2.96 / 161.99 | 2 | 21 |
7 | 8 | 0.28 | 165 | 15.24 | 420 | 1056 | 4.02 / 163.05 | 2 | 18 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 11 | 15.29 | 596 | 100 | 0.10 / 155.17 | 2 | 26 |
2 | 7 | 2004.72 | 38 | 14.89 | 3010 | 1703 | 1.80 / 156.87 | 2 | 18 |
3 | 13 | 1265.68 | 18 | 15.03 | 2111 | 571 | 2.37 / 157.44 | 2 | 23 |
4 | 13 | 711.36 | 18 | 15.14 | 1408 | 384 | 2.76 / 157.82 | 2 | 27 |
5 | 13 | 68.92 | 18 | 15.32 | 520 | 143 | 2.90 / 157.97 | 2 | 25 |
6 | 8 | 0.36 | 165 | 15.28 | 422 | 1064 | 3.97 / 159.03 | 2 | 17 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 11 | 15.31 | 598 | 101 | 0.10 / 152.25 | 2 | 26 |
2 | 3 | 984.76 | -1 | 15.56 | 0 | 0 | 0.00 / 152.25 | 2 | 26 |
3 | 7 | 2004.16 | 38 | 14.88 | 3014 | 1704 | 1.80 / 153.96 | 2 | 18 |
4 | 13 | 1477.96 | 18 | 14.97 | 2376 | 640 | 2.45 / 154.60 | 2 | 22 |
5 | 13 | 708.16 | 18 | 15.13 | 1407 | 383 | 2.83 / 154.98 | 2 | 27 |
6 | 13 | 72.40 | 6 | 15.31 | 528 | 49 | 2.88 / 155.03 | 2 | 25 |
7 | 13 | 47.24 | 5 | 15.33 | 496 | 38 | 2.91 / 155.07 | 2 | 21 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 9 | 15.31 | 588 | 81 | 0.08 / 149.25 | 2 | 25 |
2 | 10 | 1007.28 | 3 | 15.16 | 1873 | 85 | 0.17 / 149.34 | 2 | 23 |
3 | 7 | 2007.96 | 38 | 14.89 | 3030 | 1714 | 1.88 / 151.05 | 2 | 18 |
4 | 13 | 1438.16 | 18 | 14.99 | 2337 | 631 | 2.51 / 151.68 | 2 | 22 |
5 | 13 | 728.88 | 18 | 15.14 | 1436 | 391 | 2.90 / 152.08 | 2 | 27 |
6 | 13 | 60.40 | 5 | 15.34 | 515 | 40 | 2.94 / 152.12 | 2 | 23 |
7 | 13 | 21.60 | 5 | 15.34 | 450 | 35 | 2.98 / 152.15 | 2 | 11 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 11 | 15.30 | 610 | 103 | 0.10 / 146.41 | 2 | 26 |
2 | 3 | 923.44 | -3 | 15.57 | 0 | 0 | 0.00 / 146.41 | 2 | 26 |
3 | 7 | 2004.12 | 38 | 14.91 | 3029 | 1716 | 1.82 / 148.12 | 2 | 18 |
4 | 13 | 1368.92 | 18 | 15.02 | 2246 | 607 | 2.43 / 148.73 | 2 | 23 |
5 | 13 | 746.44 | 18 | 15.14 | 1455 | 397 | 2.82 / 149.13 | 2 | 27 |
6 | 13 | 66.12 | 6 | 15.34 | 517 | 48 | 2.87 / 149.17 | 2 | 24 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 9 | 15.29 | 602 | 83 | 0.08 / 143.50 | 2 | 25 |
2 | 10 | 1039.84 | 2 | 15.16 | 1924 | 58 | 0.14 / 143.56 | 2 | 22 |
3 | 3 | 1040.24 | 1 | 15.20 | 1906 | 29 | 0.17 / 143.59 | 2 | 19 |
4 | 7 | 2008.20 | 38 | 14.89 | 3030 | 1714 | 1.88 / 145.30 | 2 | 18 |
5 | 13 | 1296.36 | 18 | 15.03 | 2153 | 582 | 2.47 / 145.89 | 2 | 23 |
6 | 13 | 664.20 | 18 | 15.15 | 1355 | 370 | 2.84 / 146.26 | 2 | 27 |
7 | 13 | 64.04 | 6 | 15.34 | 517 | 48 | 2.88 / 146.30 | 2 | 24 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 9 | 15.32 | 609 | 84 | 0.08 / 140.61 | 2 | 25 |
2 | 7 | 2008.72 | 39 | 14.90 | 3028 | 1760 | 1.84 / 142.37 | 2 | 18 |
3 | 13 | 1250.28 | 18 | 15.04 | 2099 | 568 | 2.41 / 142.94 | 2 | 23 |
4 | 13 | 736.36 | 18 | 15.14 | 1441 | 393 | 2.80 / 143.33 | 2 | 26 |
5 | 13 | 64.80 | 6 | 15.35 | 518 | 48 | 2.85 / 143.38 | 2 | 24 |
6 | 13 | 52.76 | 5 | 15.34 | 512 | 39 | 2.89 / 143.42 | 2 | 23 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 9 | 15.32 | 593 | 82 | 0.08 / 137.76 | 2 | 25 |
2 | 3 | 984.84 | -1 | 15.60 | 1 | 0 | 0.00 / 137.76 | 2 | 25 |
3 | 7 | 2007.92 | 39 | 14.91 | 3030 | 1762 | 1.84 / 139.52 | 2 | 18 |
4 | 13 | 1301.44 | 18 | 15.05 | 2169 | 588 | 2.43 / 140.11 | 2 | 22 |
5 | 13 | 678.56 | 18 | 15.16 | 1367 | 373 | 2.80 / 140.48 | 2 | 26 |
6 | 13 | 68.24 | 6 | 15.34 | 524 | 48 | 2.85 / 140.53 | 2 | 23 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 9 | 15.31 | 600 | 83 | 0.08 / 134.97 | 2 | 25 |
2 | 7 | 2005.04 | 38 | 14.91 | 3015 | 1708 | 1.79 / 136.68 | 2 | 17 |
3 | 13 | 1297.00 | 18 | 15.04 | 2156 | 584 | 2.37 / 137.26 | 2 | 22 |
4 | 13 | 663.96 | 18 | 15.15 | 1344 | 367 | 2.74 / 137.63 | 2 | 26 |
5 | 13 | 67.32 | 6 | 15.34 | 510 | 47 | 2.79 / 137.68 | 2 | 23 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 12 | 15.31 | 599 | 110 | 0.11 / 132.16 | 2 | 25 |
2 | 3 | 885.88 | -4 | 15.59 | 1 | 0 | 0.00 / 132.16 | 2 | 25 |
3 | 7 | 2007.32 | 38 | 14.92 | 3026 | 1716 | 1.83 / 133.87 | 2 | 17 |
4 | 13 | 1302.88 | 18 | 15.04 | 2171 | 588 | 2.41 / 134.46 | 2 | 22 |
5 | 13 | 707.88 | 18 | 15.15 | 1401 | 382 | 2.80 / 134.84 | 2 | 26 |
6 | 13 | 64.24 | 6 | 15.35 | 505 | 47 | 2.84 / 134.89 | 2 | 23 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 11 | 15.31 | 594 | 100 | 0.10 / 129.27 | 2 | 24 |
2 | 7 | 2006.16 | 39 | 14.92 | 3036 | 1767 | 1.87 / 131.04 | 2 | 17 |
3 | 13 | 1301.40 | 18 | 15.05 | 2174 | 589 | 2.46 / 131.63 | 2 | 22 |
4 | 13 | 660.72 | 18 | 15.17 | 1349 | 368 | 2.82 / 132.00 | 2 | 26 |
5 | 13 | 72.92 | 6 | 15.33 | 537 | 49 | 2.87 / 132.05 | 2 | 24 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 8 | 15.33 | 599 | 73 | 0.07 / 126.30 | 2 | 24 |
2 | 10 | 1048.52 | 3 | 15.17 | 1909 | 87 | 0.16 / 126.39 | 2 | 21 |
3 | 3 | 1044.16 | 1 | 15.21 | 1880 | 29 | 0.19 / 126.42 | 2 | 19 |
4 | 7 | 2007.04 | 38 | 14.92 | 3018 | 1711 | 1.90 / 128.13 | 2 | 17 |
5 | 13 | 1304.64 | 18 | 15.05 | 2167 | 587 | 2.49 / 128.71 | 2 | 22 |
6 | 13 | 664.00 | 18 | 15.17 | 1350 | 369 | 2.86 / 129.08 | 2 | 26 |
7 | 13 | 77.24 | 6 | 15.34 | 533 | 49 | 2.90 / 129.13 | 2 | 24 |
8 | 13 | 59.48 | 5 | 15.34 | 516 | 40 | 2.94 / 129.17 | 2 | 22 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 9 | 15.33 | 592 | 82 | 0.08 / 123.47 | 2 | 24 |
2 | 3 | 985.68 | -1 | 15.64 | 2 | 0 | 0.00 / 123.47 | 2 | 24 |
3 | 7 | 2006.72 | 38 | 14.92 | 3036 | 1721 | 1.80 / 125.20 | 2 | 17 |
4 | 13 | 1260.84 | 18 | 15.07 | 2119 | 575 | 2.38 / 125.77 | 2 | 22 |
5 | 13 | 673.72 | 18 | 15.18 | 1355 | 370 | 2.75 / 126.14 | 2 | 26 |
6 | 13 | 71.40 | 6 | 15.36 | 532 | 49 | 2.80 / 126.19 | 2 | 24 |
7 | 13 | 48.68 | 5 | 15.37 | 501 | 39 | 2.84 / 126.23 | 2 | 20 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 9 | 15.33 | 604 | 83 | 0.08 / 120.64 | 2 | 24 |
2 | 3 | 983.00 | -1 | 15.62 | 1 | 0 | 0.00 / 120.64 | 2 | 24 |
3 | 7 | 2005.48 | 38 | 14.92 | 3028 | 1717 | 1.80 / 122.36 | 2 | 17 |
4 | 13 | 1314.00 | 18 | 15.06 | 2179 | 591 | 2.39 / 122.95 | 2 | 22 |
5 | 13 | 737.20 | 18 | 15.16 | 1455 | 397 | 2.79 / 123.34 | 2 | 26 |
6 | 13 | 70.32 | 6 | 15.35 | 522 | 48 | 2.84 / 123.39 | 2 | 24 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 11 | 15.36 | 594 | 100 | 0.10 / 117.84 | 2 | 24 |
2 | 3 | 921.60 | -3 | 15.61 | 1 | 0 | 0.00 / 117.84 | 2 | 24 |
3 | 7 | 2006.60 | 38 | 14.94 | 3031 | 1721 | 1.82 / 119.56 | 2 | 17 |
4 | 13 | 1294.00 | 18 | 15.07 | 2158 | 585 | 2.41 / 120.14 | 2 | 22 |
5 | 13 | 651.60 | 18 | 15.19 | 1327 | 363 | 2.77 / 120.51 | 2 | 26 |
6 | 13 | 86.04 | 6 | 15.36 | 535 | 49 | 2.82 / 120.56 | 2 | 25 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 9 | 15.34 | 602 | 83 | 0.08 / 114.96 | 2 | 24 |
2 | 10 | 1029.40 | 2 | 15.22 | 1886 | 57 | 0.14 / 115.01 | 2 | 21 |
3 | 7 | 2006.12 | 38 | 14.93 | 3026 | 1717 | 1.86 / 116.73 | 2 | 17 |
4 | 13 | 1298.28 | 18 | 15.07 | 2162 | 586 | 2.44 / 117.32 | 2 | 22 |
5 | 13 | 665.84 | 18 | 15.20 | 1355 | 371 | 2.81 / 117.69 | 2 | 26 |
6 | 13 | 71.96 | 6 | 15.36 | 532 | 49 | 2.86 / 117.74 | 2 | 24 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 10 | 15.35 | 607 | 93 | 0.09 / 112.09 | 2 | 24 |
2 | 3 | 965.68 | -1 | 15.62 | 1 | 0 | 0.00 / 112.09 | 2 | 24 |
3 | 7 | 2007.72 | 39 | 14.94 | 3042 | 1772 | 1.87 / 113.87 | 2 | 17 |
4 | 13 | 1296.96 | 18 | 15.08 | 2165 | 588 | 2.45 / 114.45 | 2 | 22 |
5 | 13 | 659.04 | 18 | 15.20 | 1349 | 369 | 2.82 / 114.82 | 2 | 26 |
6 | 13 | 91.84 | 6 | 15.36 | 546 | 50 | 2.87 / 114.87 | 2 | 25 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 13 | 15.33 | 606 | 121 | 0.12 / 109.21 | 2 | 24 |
2 | 3 | 877.12 | -4 | 15.60 | 1 | 0 | 0.00 / 109.21 | 2 | 24 |
3 | 7 | 2004.36 | 39 | 14.95 | 3034 | 1769 | 1.89 / 110.98 | 2 | 17 |
4 | 13 | 1289.72 | 18 | 15.09 | 2148 | 583 | 2.47 / 111.57 | 2 | 22 |
5 | 13 | 706.44 | 18 | 15.20 | 1416 | 387 | 2.86 / 111.95 | 2 | 26 |
6 | 13 | 66.72 | 6 | 15.37 | 526 | 49 | 2.91 / 112.00 | 2 | 23 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 10 | 15.34 | 602 | 92 | 0.09 / 106.25 | 2 | 24 |
2 | 10 | 1030.80 | 3 | 15.18 | 1908 | 87 | 0.18 / 106.34 | 2 | 21 |
3 | 3 | 1037.12 | 1 | 15.23 | 1915 | 29 | 0.21 / 106.37 | 2 | 17 |
4 | 7 | 2004.68 | 38 | 14.94 | 3029 | 1720 | 1.93 / 108.09 | 2 | 17 |
5 | 13 | 1288.84 | 18 | 15.07 | 2155 | 585 | 2.51 / 108.67 | 2 | 22 |
6 | 13 | 662.16 | 18 | 15.19 | 1356 | 371 | 2.88 / 109.05 | 2 | 26 |
7 | 13 | 62.52 | 6 | 15.37 | 505 | 47 | 2.93 / 109.09 | 2 | 23 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 11 | 15.34 | 590 | 100 | 0.10 / 103.39 | 2 | 24 |
2 | 3 | 956.16 | -2 | 15.61 | 1 | 0 | 0.00 / 103.39 | 2 | 24 |
3 | 7 | 2003.60 | 38 | 14.96 | 3023 | 1719 | 1.82 / 105.11 | 2 | 17 |
4 | 13 | 1275.56 | 18 | 15.09 | 2140 | 581 | 2.40 / 105.69 | 2 | 22 |
5 | 13 | 705.80 | 18 | 15.17 | 1407 | 384 | 2.78 / 106.07 | 2 | 25 |
6 | 13 | 90.28 | 6 | 15.36 | 556 | 51 | 2.83 / 106.12 | 2 | 25 |
7 | 13 | 49.68 | 5 | 15.38 | 504 | 39 | 2.87 / 106.16 | 2 | 21 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 14 | 15.33 | 599 | 129 | 0.13 / 100.50 | 2 | 25 |
2 | 3 | 860.88 | -5 | 15.60 | 1 | 0 | 0.00 / 100.50 | 2 | 25 |
3 | 7 | 2007.68 | 38 | 14.94 | 3040 | 1726 | 1.85 / 102.23 | 2 | 17 |
4 | 13 | 1388.96 | 18 | 15.05 | 2276 | 617 | 2.47 / 102.84 | 2 | 21 |
5 | 13 | 775.24 | 18 | 15.17 | 1491 | 407 | 2.88 / 103.25 | 2 | 25 |
6 | 13 | 53.88 | 5 | 15.37 | 494 | 38 | 2.92 / 103.29 | 2 | 21 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 10 | 15.36 | 608 | 93 | 0.09 / 97.51 | 2 | 24 |
2 | 10 | 1067.92 | 3 | 15.18 | 1962 | 89 | 0.18 / 97.60 | 2 | 21 |
3 | 3 | 1078.84 | 2 | 15.21 | 1979 | 60 | 0.24 / 97.66 | 2 | 21 |
4 | 7 | 2002.52 | 38 | 14.94 | 3025 | 1717 | 1.96 / 99.38 | 2 | 17 |
5 | 13 | 1212.76 | 18 | 15.08 | 2064 | 560 | 2.52 / 99.94 | 2 | 22 |
6 | 13 | 711.60 | 18 | 15.18 | 1412 | 386 | 2.91 / 100.32 | 2 | 25 |
7 | 13 | 76.52 | 6 | 15.36 | 538 | 50 | 2.96 / 100.37 | 2 | 24 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 10 | 15.36 | 609 | 94 | 0.09 / 94.69 | 2 | 25 |
2 | 3 | 979.04 | -1 | 15.63 | 1 | 0 | 0.00 / 94.69 | 2 | 25 |
3 | 7 | 2002.88 | 38 | 14.95 | 3031 | 1722 | 1.82 / 96.41 | 2 | 17 |
4 | 13 | 1294.68 | 18 | 15.08 | 2168 | 588 | 2.40 / 97.00 | 2 | 22 |
5 | 13 | 658.92 | 18 | 15.20 | 1355 | 371 | 2.77 / 97.37 | 2 | 26 |
6 | 13 | 67.68 | 6 | 15.37 | 520 | 48 | 2.82 / 97.42 | 2 | 23 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 11 | 15.35 | 593 | 100 | 0.10 / 91.81 | 2 | 24 |
2 | 3 | 966.68 | -1 | 15.64 | 2 | 0 | 0.00 / 91.81 | 2 | 24 |
3 | 7 | 2008.44 | 39 | 14.96 | 3035 | 1771 | 1.87 / 93.58 | 2 | 17 |
4 | 13 | 1353.00 | 18 | 15.07 | 2239 | 607 | 2.48 / 94.19 | 2 | 21 |
5 | 13 | 649.84 | 18 | 15.22 | 1336 | 366 | 2.84 / 94.56 | 2 | 26 |
6 | 13 | 59.92 | 5 | 15.39 | 504 | 39 | 2.88 / 94.59 | 2 | 22 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 12 | 15.37 | 612 | 113 | 0.11 / 89.04 | 2 | 25 |
2 | 3 | 946.00 | -2 | 15.65 | 1 | 0 | 0.00 / 89.04 | 2 | 25 |
3 | 7 | 2005.72 | 38 | 14.96 | 3029 | 1722 | 1.83 / 90.76 | 2 | 17 |
4 | 13 | 1240.68 | 18 | 15.10 | 2094 | 569 | 2.40 / 91.33 | 2 | 22 |
5 | 13 | 588.60 | 18 | 15.23 | 1257 | 345 | 2.75 / 91.67 | 2 | 26 |
6 | 13 | 61.36 | 5 | 15.39 | 501 | 39 | 2.79 / 91.71 | 2 | 22 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 15 | 15.35 | 599 | 138 | 0.14 / 86.14 | 2 | 25 |
2 | 3 | 890.92 | -4 | 15.63 | 1 | 0 | 0.00 / 86.14 | 2 | 25 |
3 | 3 | 1018.00 | 1 | 15.31 | 1888 | 29 | 0.17 / 86.17 | 2 | 10 |
4 | 7 | 2003.84 | 38 | 14.99 | 3034 | 1728 | 1.90 / 87.90 | 2 | 17 |
5 | 13 | 1344.60 | 18 | 15.10 | 2238 | 608 | 2.50 / 88.50 | 2 | 21 |
6 | 13 | 658.44 | 18 | 15.22 | 1354 | 371 | 2.87 / 88.88 | 2 | 26 |
7 | 13 | 68.28 | 6 | 15.40 | 528 | 49 | 2.92 / 88.92 | 2 | 23 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 28 | 15.33 | 613 | 263 | 0.26 / 83.37 | 2 | 26 |
2 | 3 | 517.68 | -17 | 15.63 | 1 | 0 | 0.00 / 83.37 | 2 | 26 |
3 | 3 | 865.32 | -5 | 15.66 | 1 | 0 | 0.00 / 83.37 | 2 | 26 |
4 | 7 | 1937.60 | 38 | 15.00 | 2941 | 1676 | 1.94 / 85.05 | 2 | 18 |
5 | 13 | 1207.44 | 18 | 15.12 | 2053 | 559 | 2.50 / 85.61 | 2 | 22 |
6 | 13 | 590.84 | 18 | 15.24 | 1255 | 344 | 2.84 / 85.95 | 2 | 26 |
7 | 13 | 71.88 | 6 | 15.39 | 534 | 49 | 2.89 / 86.00 | 2 | 23 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 28 | 15.34 | 623 | 268 | 0.27 / 80.36 | 2 | 26 |
2 | 3 | 1017.92 | 1 | 15.31 | 1866 | 29 | 0.30 / 80.39 | 2 | 10 |
3 | 7 | 2005.88 | 38 | 14.98 | 3026 | 1723 | 2.02 / 82.11 | 2 | 17 |
4 | 13 | 1239.52 | 18 | 15.12 | 2094 | 570 | 2.59 / 82.68 | 2 | 22 |
5 | 13 | 688.68 | 18 | 15.22 | 1386 | 380 | 2.97 / 83.06 | 2 | 25 |
6 | 13 | 74.60 | 6 | 15.38 | 533 | 49 | 3.02 / 83.11 | 2 | 23 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 28 | 15.26 | 609 | 260 | 0.26 / 77.36 | 2 | 27 |
2 | 7 | 2008.56 | 38 | 14.99 | 3023 | 1722 | 1.98 / 79.08 | 2 | 17 |
3 | 13 | 1355.08 | 18 | 15.10 | 2231 | 606 | 2.59 / 79.68 | 2 | 21 |
4 | 13 | 633.80 | 18 | 15.24 | 1306 | 358 | 2.95 / 80.04 | 2 | 26 |
5 | 13 | 81.88 | 6 | 15.40 | 538 | 50 | 3.00 / 80.09 | 2 | 24 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 28 | 15.27 | 608 | 260 | 0.26 / 73.23 | 2 | 27 |
2 | 7 | 2004.24 | 39 | 15.00 | 3029 | 1772 | 2.03 / 75.00 | 2 | 17 |
3 | 13 | 1291.48 | 18 | 15.12 | 2162 | 588 | 2.62 / 75.59 | 2 | 22 |
4 | 13 | 658.48 | 18 | 15.24 | 1356 | 372 | 2.99 / 75.96 | 2 | 25 |
5 | 13 | 62.64 | 6 | 15.41 | 523 | 48 | 3.04 / 76.01 | 2 | 23 |
6 | 8 | 0.00 | 165 | 15.36 | 427 | 1082 | 4.12 / 77.10 | 2 | 15 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 28 | 15.27 | 604 | 258 | 0.26 / 69.18 | 2 | 27 |
2 | 7 | 2003.84 | 38 | 15.01 | 3004 | 1713 | 1.97 / 70.89 | 2 | 17 |
3 | 13 | 1238.64 | 18 | 15.12 | 2093 | 570 | 2.54 / 71.46 | 2 | 22 |
4 | 13 | 706.72 | 18 | 15.22 | 1405 | 385 | 2.93 / 71.85 | 2 | 25 |
5 | 13 | 86.32 | 6 | 15.41 | 553 | 51 | 2.98 / 71.90 | 2 | 25 |
6 | 8 | 0.20 | 165 | 15.36 | 424 | 1075 | 4.05 / 72.97 | 2 | 16 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 28 | 15.28 | 596 | 255 | 0.25 / 65.05 | 2 | 26 |
2 | 3 | 1017.32 | 1 | 15.29 | 1874 | 29 | 0.28 / 65.07 | 2 | 11 |
3 | 7 | 2007.56 | 38 | 14.98 | 3031 | 1725 | 2.01 / 66.80 | 2 | 17 |
4 | 13 | 1285.12 | 18 | 15.13 | 2147 | 585 | 2.59 / 67.38 | 2 | 22 |
5 | 13 | 620.64 | 18 | 15.25 | 1300 | 357 | 2.95 / 67.74 | 2 | 26 |
6 | 13 | 65.04 | 6 | 15.41 | 525 | 49 | 3.00 / 67.79 | 2 | 22 |
7 | 13 | 42.76 | 5 | 15.42 | 492 | 38 | 3.04 / 67.83 | 2 | 18 |
8 | 8 | 0.08 | 165 | 15.36 | 431 | 1092 | 4.13 / 68.92 | 2 | 17 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 28 | 15.28 | 606 | 259 | 0.26 / 60.97 | 2 | 26 |
2 | 7 | 2007.80 | 38 | 15.00 | 3022 | 1723 | 1.98 / 62.69 | 2 | 17 |
3 | 13 | 1296.20 | 18 | 15.13 | 2162 | 589 | 2.57 / 63.28 | 2 | 22 |
4 | 13 | 638.08 | 18 | 15.25 | 1319 | 362 | 2.93 / 63.64 | 2 | 26 |
5 | 13 | 69.96 | 6 | 15.41 | 538 | 50 | 2.98 / 63.69 | 2 | 24 |
6 | 8 | 0.28 | 165 | 15.36 | 434 | 1100 | 4.08 / 64.79 | 2 | 17 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 27 | 15.28 | 598 | 247 | 0.25 / 56.87 | 2 | 25 |
2 | 3 | 1018.52 | 1 | 15.29 | 1871 | 29 | 0.28 / 56.90 | 2 | 12 |
3 | 7 | 2007.68 | 38 | 15.02 | 3041 | 1736 | 2.01 / 58.63 | 2 | 17 |
4 | 13 | 1282.48 | 18 | 15.13 | 2144 | 584 | 2.59 / 59.22 | 2 | 21 |
5 | 13 | 595.32 | 18 | 15.26 | 1269 | 349 | 2.94 / 59.57 | 2 | 26 |
6 | 13 | 62.04 | 6 | 15.42 | 525 | 49 | 2.99 / 59.62 | 2 | 23 |
7 | 8 | -0.12 | 165 | 15.37 | 431 | 1093 | 4.09 / 60.71 | 2 | 14 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 27 | 15.27 | 603 | 249 | 0.25 / 52.77 | 2 | 25 |
2 | 7 | 2003.76 | 38 | 15.02 | 3029 | 1729 | 1.98 / 54.50 | 2 | 17 |
3 | 13 | 1296.56 | 18 | 15.13 | 2163 | 589 | 2.57 / 55.09 | 2 | 21 |
4 | 13 | 706.76 | 18 | 15.23 | 1416 | 388 | 2.95 / 55.48 | 2 | 25 |
5 | 13 | 68.64 | 6 | 15.42 | 542 | 50 | 3.00 / 55.53 | 2 | 23 |
6 | 8 | 0.36 | 165 | 15.37 | 431 | 1093 | 4.10 / 56.62 | 2 | 16 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 27 | 15.28 | 602 | 248 | 0.25 / 48.60 | 2 | 25 |
2 | 7 | 2010.00 | 38 | 15.02 | 3041 | 1736 | 1.98 / 50.34 | 2 | 17 |
3 | 13 | 1232.12 | 18 | 15.15 | 2088 | 569 | 2.55 / 50.91 | 2 | 22 |
4 | 13 | 610.00 | 18 | 15.26 | 1284 | 353 | 2.91 / 51.26 | 2 | 26 |
5 | 13 | 60.76 | 5 | 15.42 | 534 | 41 | 2.95 / 51.30 | 2 | 22 |
6 | 13 | 17.60 | 18 | 15.42 | 463 | 129 | 3.08 / 51.43 | 2 | 8 |
7 | 8 | 0.16 | 165 | 15.36 | 433 | 1097 | 4.17 / 52.53 | 2 | 16 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 27 | 15.27 | 607 | 250 | 0.25 / 44.56 | 2 | 25 |
2 | 7 | 2002.60 | 38 | 15.03 | 3021 | 1725 | 1.98 / 46.29 | 2 | 17 |
3 | 13 | 1246.60 | 18 | 15.15 | 2102 | 573 | 2.55 / 46.86 | 2 | 22 |
4 | 13 | 608.64 | 18 | 15.27 | 1287 | 354 | 2.90 / 47.21 | 2 | 26 |
5 | 13 | 65.56 | 6 | 15.43 | 526 | 49 | 2.95 / 47.26 | 2 | 23 |
6 | 8 | -0.04 | 165 | 15.37 | 430 | 1091 | 4.04 / 48.35 | 2 | 14 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 27 | 15.28 | 608 | 251 | 0.25 / 39.62 | 2 | 25 |
2 | 3 | 1017.16 | 1 | 15.37 | 1844 | 28 | 0.28 / 39.65 | 2 | 14 |
3 | 7 | 2003.24 | 74 | 14.88 | 3016 | 3321 | 3.60 / 42.97 | 2 | 17 |
4 | 13 | 311.36 | 18 | 15.33 | 883 | 244 | 3.84 / 43.21 | 2 | 27 |
5 | 8 | 0.32 | 165 | 15.36 | 433 | 1097 | 4.94 / 44.31 | 2 | 18 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 25 | 15.29 | 605 | 231 | 0.23 / 34.68 | 2 | 25 |
2 | 10 | 1028.40 | 2 | 15.23 | 1902 | 58 | 0.29 / 34.74 | 2 | 20 |
3 | 7 | 2008.40 | 74 | 14.88 | 3022 | 3328 | 3.62 / 38.07 | 2 | 18 |
4 | 13 | 203.92 | 18 | 15.37 | 736 | 204 | 3.82 / 38.27 | 2 | 27 |
5 | 8 | 0.04 | 165 | 15.35 | 434 | 1099 | 4.92 / 39.37 | 2 | 16 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 28 | 15.27 | 616 | 263 | 0.26 / 29.87 | 2 | 25 |
2 | 3 | 919.48 | -2 | 15.69 | 1 | 0 | 0.00 / 29.87 | 2 | 25 |
3 | 7 | 2003.76 | 74 | 14.90 | 3014 | 3323 | 3.59 / 33.20 | 2 | 17 |
4 | 13 | 221.60 | 10 | 15.39 | 760 | 117 | 3.70 / 33.31 | 2 | 27 |
5 | 13 | 60.04 | 5 | 15.43 | 525 | 41 | 3.74 / 33.35 | 2 | 22 |
6 | 8 | 0.08 | 165 | 15.37 | 432 | 1096 | 4.84 / 34.45 | 2 | 18 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 26 | 15.30 | 607 | 241 | 0.24 / 25.46 | 2 | 25 |
2 | 7 | 1705.08 | 74 | 14.96 | 2649 | 2933 | 3.17 / 28.40 | 2 | 18 |
3 | 13 | 106.40 | 7 | 15.39 | 603 | 65 | 3.24 / 28.46 | 2 | 26 |
4 | 13 | 64.96 | 6 | 15.40 | 539 | 50 | 3.29 / 28.51 | 2 | 22 |
5 | 8 | 0.12 | 165 | 15.35 | 434 | 1099 | 4.39 / 29.61 | 2 | 16 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 26 | 15.30 | 608 | 242 | 0.24 / 21.47 | 2 | 25 |
2 | 7 | 1498.28 | 74 | 15.03 | 2388 | 2656 | 2.90 / 24.12 | 2 | 20 |
3 | 8 | 0.16 | 165 | 15.38 | 433 | 1099 | 4.00 / 25.22 | 2 | 16 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 26 | 15.32 | 605 | 241 | 0.24 / 17.41 | 2 | 25 |
2 | 7 | 1519.20 | 74 | 15.03 | 2413 | 2684 | 2.92 / 20.10 | 2 | 20 |
3 | 13 | 51.12 | 5 | 15.44 | 513 | 40 | 2.96 / 20.14 | 2 | 21 |
4 | 8 | 0.08 | 165 | 15.38 | 429 | 1089 | 4.05 / 21.23 | 2 | 14 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 25 | 15.34 | 608 | 233 | 0.23 / 13.56 | 2 | 24 |
2 | 3 | 1023.72 | 1 | 15.34 | 1889 | 29 | 0.26 / 13.59 | 2 | 20 |
3 | 7 | 1383.08 | 74 | 15.09 | 2242 | 2504 | 2.77 / 16.09 | 2 | 21 |
4 | 8 | 0.00 | 165 | 15.40 | 426 | 1082 | 3.85 / 17.17 | 2 | 21 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 22 | 15.31 | 610 | 205 | 0.21 / 9.72 | 2 | 25 |
2 | 10 | 1029.92 | 3 | 15.22 | 1900 | 87 | 0.29 / 9.81 | 2 | 20 |
3 | 3 | 1032.96 | 1 | 15.33 | 1878 | 29 | 0.32 / 9.83 | 2 | 21 |
4 | 7 | 1303.48 | 74 | 15.12 | 2147 | 2402 | 2.72 / 12.24 | 2 | 22 |
5 | 8 | 0.12 | 165 | 15.40 | 428 | 1088 | 3.81 / 13.32 | 2 | 15 |
Average= | 3.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 31 | 15.34 | 606 | 288 | 0.29 / 5.75 | 2 | 26 |
2 | 3 | 771.76 | -4 | 15.71 | 1 | 0 | 0.00 / 5.75 | 2 | 26 |
3 | 3 | 885.72 | -2 | 15.73 | 1 | 0 | 0.00 / 5.75 | 2 | 26 |
4 | 7 | 1506.72 | 74 | 15.05 | 2392 | 2664 | 2.95 / 8.42 | 2 | 19 |
5 | 13 | 53.40 | 5 | 15.44 | 503 | 39 | 2.99 / 8.45 | 2 | 22 |
6 | 8 | 0.20 | 165 | 15.39 | 417 | 1059 | 4.05 / 9.51 | 2 | 19 |
Average= | 3.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 26 | 15.51 | 548 | 221 | 0.22 / 2.44 | 2 | 16 |
2 | 3 | 946.64 | -1 | 15.72 | 1 | 0 | 0.00 / 2.44 | 2 | 16 |
3 | 7 | 975.36 | 75 | 15.20 | 1712 | 1952 | 2.17 / 4.39 | 2 | 23 |
4 | 8 | 0.00 | 165 | 15.43 | 421 | 1072 | 3.24 / 5.46 | 2 | 18 |
Average= | 2.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 163.16 | 25 | 15.69 | 592 | 232 | 0.23 / 0.23 | 2 | 6 |
2 | 7 | 177.28 | 75 | 15.64 | 587 | 689 | 0.92 / 0.92 | 2 | 9 |
3 | 8 | 0.24 | 240 | 15.59 | 347 | 1298 | 2.22 / 2.22 | 2 | 25 |
Average= | 2.22 (KJ/cycle) |