SIO Argo Site:
Pump Diagnostics Page   



Serial= 8920 WMO= 7900803

Return

←PreviousNext→

Cycle 145 GMT 4/12/2024 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 19 15.03 536 153 0.15 / 439.13 2 2
2 3 960.52 -1 15.36 0 0 0.00 / 439.13 2 2
3 7 2004.72 34 14.58 2873 1424 1.58 / 440.56 2 2
4 13 1586.68 29 14.61 2368 1003 2.58 / 441.56 2 3
5 13 638.48 29 14.84 1197 515 3.10 / 442.07 2 3
6 8 0.28 165 15.04 335 831 3.93 / 442.91 2 6
Average= 88.58
(KJ/cycle)

Cycle 144

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 18 15.03 482 130 0.13 / 435.98 2 2
2 3 1058.32 2 14.92 1798 54 0.18 / 436.04 2 2
3 7 2004.44 33 14.61 2875 1386 1.57 / 437.42 2 2
4 13 1607.88 29 14.60 2390 1012 2.58 / 438.43 2 3
5 13 694.28 29 14.82 1268 545 3.13 / 438.98 2 4
Average= 109.74
(KJ/cycle)

Cycle 143

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 18 15.01 539 146 0.15 / 432.91 2 2
2 7 2003.48 33 14.59 2868 1381 1.53 / 434.29 2 2
3 13 1585.48 29 14.61 2360 1000 2.53 / 435.29 2 3
4 13 654.76 29 14.84 1215 523 3.05 / 435.81 2 5
5 13 69.00 6 15.06 469 42 3.09 / 435.85 2 4
Average= 145.28
(KJ/cycle)

Cycle 142

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 18 15.04 496 134 0.13 / 429.79 2 2
2 7 2004.56 33 14.60 2856 1376 1.51 / 431.16 2 2
3 13 1601.72 29 14.59 2377 1006 2.52 / 432.17 2 3
4 13 798.48 29 14.78 1383 593 3.11 / 432.76 2 4
Average= 216.38
(KJ/cycle)

Cycle 141

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 19 15.03 512 146 0.15 / 426.67 2 3
2 3 937.84 -2 15.38 0 0 0.00 / 426.67 2 3
3 7 2003.16 33 14.62 2872 1386 1.53 / 428.05 2 2
4 13 1595.32 29 14.62 2383 1010 2.54 / 429.06 2 3
5 13 789.72 29 14.81 1368 588 3.13 / 429.65 2 4
Average= 429.65
(KJ/cycle)

Cycle 123 GMT 3/ 5/2024 11:21:31

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 29 14.99 489 213 0.21 / 422.70 2 2
2 7 2003.32 33 14.62 2851 1375 1.59 / 424.08 2 2
3 13 1578.20 29 14.62 2335 990 2.58 / 425.07 2 3
4 13 810.16 29 14.79 1409 604 3.18 / 425.67 2 3
5 13 45.32 5 15.10 419 32 3.21 / 425.70 2 3
6 8 0.20 165 15.05 330 819 4.03 / 426.52 2 5
Average= 3.44
(KJ/cycle)

Cycle 122 GMT 23/ 4/2024 16:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 29 15.00 480 209 0.21 / 418.79 2 2
2 7 2002.84 33 14.62 2862 1381 1.59 / 420.17 2 2
3 13 1594.24 29 14.62 2365 1003 2.59 / 421.17 2 3
4 13 660.60 29 14.85 1202 518 3.11 / 421.69 2 4
5 8 0.08 165 15.06 322 800 3.91 / 422.49 2 5
Average= 3.43
(KJ/cycle)

Cycle 121 GMT 13/ 4/2024 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 14.99 482 210 0.21 / 414.92 2 2
2 7 2003.84 33 14.63 2856 1379 1.59 / 416.30 2 2
3 13 1457.80 29 14.66 2205 937 2.53 / 417.24 2 3
4 13 698.36 29 14.84 1265 544 3.07 / 417.78 2 3
5 8 0.16 165 15.07 320 796 3.87 / 418.58 2 7
Average= 3.43
(KJ/cycle)

Cycle 120 GMT 4/ 4/2024 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 29 14.99 479 208 0.21 / 410.78 2 2
2 7 2002.28 33 14.63 2860 1381 1.59 / 412.16 2 2
3 13 1587.36 29 14.63 2360 1001 2.59 / 413.16 2 3
4 13 800.60 29 14.81 1389 597 3.19 / 413.75 2 3
5 13 16.48 29 15.09 351 154 3.34 / 413.91 2 2
6 8 0.08 165 15.05 324 805 4.15 / 414.71 2 9
Average= 3.43
(KJ/cycle)

Cycle 119 GMT 25/ 3/2024 7:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 29 14.99 521 226 0.23 / 406.64 2 2
2 7 2004.80 34 14.62 2863 1423 1.65 / 408.06 2 2
3 13 1585.16 29 14.63 2354 999 2.65 / 409.06 2 3
4 13 622.20 29 14.88 1176 507 3.16 / 409.57 2 4
5 13 45.92 5 15.11 420 32 3.19 / 409.60 2 3
6 8 -0.08 165 15.06 322 800 3.99 / 410.40 2 7
7 14 -0.08 35 15.04 320 168 4.16 / 410.57 2 5
Average= 3.42
(KJ/cycle)

Cycle 118 GMT 15/ 3/2024 12:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 29 15.01 472 205 0.21 / 402.62 2 2
2 7 2003.56 34 14.61 2849 1415 1.62 / 404.03 2 2
3 13 1602.16 29 14.63 2378 1009 2.63 / 405.04 2 3
4 13 646.64 29 14.87 1207 520 3.15 / 405.56 2 4
5 8 0.32 165 15.05 342 849 4.00 / 406.41 2 5
Average= 3.42
(KJ/cycle)

Cycle 117 GMT 5/ 3/2024 17:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 29 14.99 470 204 0.20 / 398.49 2 3
2 7 2009.52 33 14.63 2844 1373 1.58 / 399.87 2 2
3 13 1582.28 29 14.65 2350 998 2.58 / 400.86 2 3
4 13 765.16 29 14.84 1356 584 3.16 / 401.45 2 3
5 13 42.72 29 15.09 392 172 3.33 / 401.62 2 4
6 8 0.00 165 15.06 319 793 4.12 / 402.41 2 5
Average= 3.41
(KJ/cycle)

Cycle 116 GMT 24/ 2/2024 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 29 15.00 471 205 0.20 / 394.44 2 2
2 7 2010.60 33 14.62 2855 1377 1.58 / 395.82 2 2
3 13 1604.36 29 14.63 2370 1006 2.59 / 396.82 2 3
4 13 667.64 29 14.87 1203 519 3.11 / 397.34 2 4
5 13 26.44 29 15.09 363 159 3.27 / 397.50 2 3
6 8 0.20 165 15.05 317 787 4.05 / 398.29 2 5
Average= 3.40
(KJ/cycle)

Cycle 115 GMT 15/ 2/2024 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 29 14.97 468 203 0.20 / 390.24 2 3
2 7 2004.36 33 14.63 2843 1373 1.58 / 391.61 2 2
3 13 1580.52 29 14.64 2344 995 2.57 / 392.61 2 3
4 13 633.52 29 14.88 1185 511 3.08 / 393.12 2 4
5 13 22.68 29 15.10 372 163 3.25 / 393.28 2 3
6 8 -0.16 165 15.06 317 788 4.03 / 394.07 2 7
7 14 -0.16 35 15.03 317 167 4.20 / 394.24 2 6
Average= 3.40
(KJ/cycle)

Cycle 114 GMT 5/ 2/2024 5:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 29 14.98 477 207 0.21 / 386.14 2 3
2 7 2005.64 33 14.63 2853 1377 1.58 / 387.51 2 3
3 13 1463.64 29 14.67 2210 940 2.52 / 388.45 2 3
4 13 713.92 29 14.85 1291 556 3.08 / 389.01 2 4
5 13 51.72 5 15.11 427 32 3.11 / 389.04 2 4
6 13 45.88 5 15.11 417 32 3.14 / 389.07 2 3
7 8 -0.12 165 15.07 320 796 3.94 / 389.87 2 8
8 14 -0.12 35 15.04 318 167 4.11 / 390.04 2 5
Average= 3.39
(KJ/cycle)

Cycle 113 GMT 26/ 1/2024 7:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 27 15.00 495 200 0.20 / 382.04 2 2
2 3 1058.72 2 14.99 1745 52 0.25 / 382.09 2 2
3 7 2002.64 33 14.63 2838 1370 1.62 / 383.47 2 2
4 13 1589.84 29 14.64 2343 995 2.62 / 384.46 2 3
5 13 662.52 29 14.86 1222 527 3.14 / 384.99 2 4
6 13 16.72 29 15.10 351 154 3.30 / 385.14 2 3
7 8 0.24 165 15.06 317 788 4.09 / 385.93 2 8
Average= 3.39
(KJ/cycle)

Cycle 112 GMT 16/ 1/2024 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 20 14.99 483 145 0.14 / 377.78 2 2
2 10 1069.08 5 14.81 1761 130 0.28 / 377.91 2 2
3 10 1105.88 2 14.84 1821 54 0.33 / 377.97 2 2
4 3 1097.36 3 14.91 1835 82 0.41 / 378.05 2 2
5 7 2003.52 34 14.62 2861 1422 1.83 / 379.47 2 3
6 13 1578.08 29 14.64 2342 994 2.83 / 380.47 2 3
7 13 630.60 29 14.88 1196 516 3.34 / 380.98 2 3
8 13 53.60 5 15.13 429 32 3.38 / 381.02 2 4
9 8 0.16 165 15.08 332 826 4.20 / 381.84 2 6
Average= 3.38
(KJ/cycle)

Cycle 111 GMT 6/ 1/2024 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 18 15.06 508 138 0.14 / 373.66 2 2
2 10 1012.64 3 14.90 1717 77 0.21 / 373.73 2 2
3 7 2002.44 33 14.62 2870 1385 1.60 / 375.12 2 2
4 13 1609.40 29 14.63 2393 1015 2.61 / 376.13 2 3
5 13 671.92 29 14.85 1248 537 3.15 / 376.67 2 3
6 13 16.48 29 15.09 363 159 3.31 / 376.83 2 3
7 8 0.08 165 15.05 326 810 4.12 / 377.64 2 4
Average= 3.37
(KJ/cycle)

Cycle 110

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 19 15.08 502 144 0.14 / 370.56 2 2
2 3 962.00 -1 15.45 0 0 0.00 / 370.56 2 2
3 7 2002.56 34 14.61 2850 1416 1.56 / 371.98 2 2
4 13 1599.04 29 14.62 2379 1009 2.57 / 372.99 2 3
5 13 667.36 29 14.86 1240 534 3.10 / 373.52 2 4
Average= 3.37
(KJ/cycle)

Cycle 109

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 17 15.06 497 127 0.13 / 367.40 2 2
2 10 1018.84 2 14.94 1721 51 0.18 / 367.45 2 2
3 7 2007.40 33 14.63 2864 1383 1.56 / 368.84 2 2
4 13 1575.48 29 14.64 2336 992 2.55 / 369.83 2 3
5 13 785.72 29 14.83 1371 590 3.14 / 370.42 2 3
Average= 3.37
(KJ/cycle)

Cycle 108

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 17 15.06 500 128 0.13 / 364.39 2 3
2 7 2006.28 33 14.62 2853 1376 1.50 / 365.77 2 2
3 13 1586.64 29 14.63 2342 994 2.50 / 366.76 2 2
4 13 639.40 29 14.86 1192 514 3.01 / 367.27 2 4
Average= 3.37
(KJ/cycle)

Cycle 107

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 17 15.04 542 139 0.14 / 361.37 2 2
2 3 1020.48 1 15.09 1746 26 0.16 / 361.40 2 2
3 7 2008.28 33 14.61 2865 1381 1.55 / 362.78 2 3
4 13 1485.16 29 14.65 2218 942 2.49 / 363.72 2 3
5 13 708.56 29 14.85 1256 541 3.03 / 364.26 2 4
Average= 3.37
(KJ/cycle)

Cycle 106

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 19 15.05 510 146 0.15 / 358.34 2 3
2 3 938.96 -2 15.41 0 0 0.00 / 358.34 2 3
3 7 2009.64 33 14.62 2850 1375 1.52 / 359.72 2 2
4 13 1589.04 29 14.61 2356 998 2.52 / 360.72 2 3
5 13 654.88 29 14.86 1198 516 3.04 / 361.23 2 4
Average= 3.38
(KJ/cycle)

Cycle 105

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 19 15.05 508 145 0.15 / 355.28 2 3
2 7 2002.20 34 14.61 2863 1422 1.57 / 356.70 2 3
3 13 1573.88 29 14.63 2344 994 2.56 / 357.70 2 3
4 13 624.76 29 14.88 1162 501 3.06 / 358.20 2 4
Average= 3.38
(KJ/cycle)

Cycle 104

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 17 15.06 504 129 0.13 / 352.19 2 3
2 10 1004.72 2 14.93 1711 51 0.18 / 352.24 2 2
3 7 2004.28 33 14.62 2844 1372 1.55 / 353.61 2 2
4 13 1594.92 29 14.64 2341 994 2.55 / 354.61 2 3
5 13 659.52 29 14.86 1225 528 3.07 / 355.13 2 3
Average= 3.38
(KJ/cycle)

Cycle 103

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 19 15.05 504 144 0.14 / 349.12 2 3
2 3 942.08 -2 15.42 0 0 0.00 / 349.12 2 3
3 7 2004.20 34 14.62 2849 1416 1.56 / 350.53 2 2
4 13 1580.52 29 14.64 2360 1002 2.56 / 351.54 2 3
5 13 655.08 29 14.87 1216 524 3.09 / 352.06 2 4
Average= 3.39
(KJ/cycle)

Cycle 102

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 19 15.07 506 145 0.14 / 346.09 2 3
2 7 2004.28 33 14.62 2851 1375 1.52 / 347.47 2 2
3 13 1579.80 29 14.65 2324 987 2.51 / 348.45 2 3
4 13 661.96 29 14.86 1204 519 3.03 / 348.97 2 3
Average= 3.39
(KJ/cycle)

Cycle 101

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 17 15.06 503 129 0.13 / 343.01 2 3
2 10 1005.76 2 14.94 1707 51 0.18 / 343.06 2 2
3 7 2002.60 33 14.62 2847 1374 1.55 / 344.44 2 2
4 13 1578.16 29 14.64 2340 993 2.55 / 345.43 2 3
5 13 642.84 29 14.88 1199 517 3.06 / 345.95 2 4
Average= 3.39
(KJ/cycle)

Cycle 100

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 18 15.06 507 137 0.14 / 339.97 2 3
2 3 943.60 -2 15.45 0 0 0.00 / 339.97 2 3
3 7 2003.52 33 14.63 2845 1374 1.51 / 341.34 2 2
4 13 1593.80 29 14.63 2373 1007 2.52 / 342.35 2 3
5 13 672.36 29 14.87 1237 533 3.05 / 342.88 2 3
Average= 3.39
(KJ/cycle)

Cycle 99

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 17 15.05 502 128 0.13 / 336.86 2 2
2 3 1045.56 1 15.03 1744 26 0.15 / 336.88 2 2
3 7 2008.52 33 14.62 2854 1377 1.53 / 338.26 2 2
4 13 1585.80 29 14.64 2342 994 2.53 / 339.25 2 2
5 13 775.56 29 14.82 1347 579 3.10 / 339.83 2 3
Average= 3.40
(KJ/cycle)

Cycle 98

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 19 15.06 496 142 0.14 / 333.80 2 3
2 3 946.92 -2 15.43 0 0 0.00 / 333.80 2 3
3 7 2003.08 34 14.62 2839 1411 1.55 / 335.21 2 2
4 13 1567.16 29 14.65 2333 991 2.54 / 336.21 2 3
5 13 667.20 29 14.87 1208 521 3.07 / 336.73 2 4
Average= 3.40
(KJ/cycle)

Cycle 97

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 19 15.08 491 141 0.14 / 330.75 2 3
2 7 2002.84 33 14.63 2854 1378 1.52 / 332.13 2 2
3 13 1592.60 29 14.64 2362 1003 2.52 / 333.13 2 3
4 13 665.32 29 14.87 1223 527 3.05 / 333.66 2 3
Average= 3.40
(KJ/cycle)

Cycle 96

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 28 15.07 480 203 0.20 / 327.73 2 3
2 3 605.76 -12 15.44 0 0 0.00 / 327.73 2 3
3 7 2002.44 33 14.65 2849 1377 1.58 / 329.11 2 2
4 13 1570.16 29 14.66 2319 986 2.57 / 330.10 2 3
5 13 644.48 29 14.90 1192 515 3.08 / 330.61 2 4
Average= 3.41
(KJ/cycle)

Cycle 95

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 20 15.02 480 144 0.14 / 324.44 2 2
2 10 1065.28 4 14.84 1762 105 0.25 / 324.54 2 2
3 10 1099.84 2 14.86 1813 54 0.30 / 324.59 2 2
4 3 1107.40 3 14.92 1836 82 0.38 / 324.68 2 2
5 7 2011.20 33 14.63 2870 1386 1.77 / 326.06 2 2
6 13 1604.60 29 14.63 2380 1010 2.78 / 327.07 2 3
7 13 535.16 29 14.91 1064 460 3.24 / 327.53 2 4
Average= 3.41
(KJ/cycle)

Cycle 94 GMT 22/ 7/2023 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 29 15.07 492 215 0.22 / 320.61 2 3
2 3 628.88 -11 15.45 0 0 0.00 / 320.61 2 3
3 7 2009.36 33 14.63 2862 1382 1.60 / 322.00 2 2
4 13 1588.80 29 14.65 2338 993 2.59 / 322.99 2 3
5 13 639.08 29 14.90 1171 506 3.10 / 323.49 2 4
6 8 0.28 165 15.09 320 797 3.89 / 324.29 2 4
Average= 3.41
(KJ/cycle)

Cycle 93

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 29 15.00 482 210 0.21 / 317.50 2 3
2 3 1017.52 1 15.10 1703 26 0.24 / 317.52 2 2
3 7 2007.96 33 14.65 2841 1373 1.61 / 318.90 2 2
4 13 1576.00 29 14.67 2337 994 2.60 / 319.89 2 3
5 13 651.96 29 14.90 1179 509 3.11 / 320.40 2 4
Average= 3.41
(KJ/cycle)

Cycle 92 GMT 2/ 7/2023 11:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 29 15.01 473 206 0.21 / 313.59 2 3
2 7 2003.80 33 14.63 2833 1368 1.57 / 314.95 2 2
3 13 1568.48 29 14.66 2298 977 2.55 / 315.93 2 3
4 13 638.52 29 14.89 1163 502 3.05 / 316.43 2 4
5 13 47.76 5 15.12 419 32 3.08 / 316.47 2 3
6 13 40.56 5 15.12 400 30 3.11 / 316.50 2 3
7 8 -0.28 165 15.07 318 791 3.91 / 317.29 2 6
Average= 3.41
(KJ/cycle)

Cycle 91 GMT 22/ 6/2023 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 28 15.01 484 203 0.20 / 309.71 2 3
2 3 1037.24 1 15.06 1734 26 0.23 / 309.73 2 2
3 7 2004.32 33 14.63 2835 1369 1.60 / 311.10 2 2
4 13 1579.60 29 14.65 2308 981 2.58 / 312.08 2 3
5 13 635.28 29 14.89 1155 499 3.08 / 312.58 2 4
6 8 0.20 165 15.08 321 799 3.88 / 313.38 2 3
Average= 3.41
(KJ/cycle)

Cycle 90 GMT 12/ 6/2023 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 29 15.02 470 205 0.20 / 305.82 2 3
2 3 960.08 -1 15.43 0 0 0.00 / 305.82 2 3
3 7 2002.40 33 14.64 2842 1373 1.58 / 307.19 2 2
4 13 1593.52 29 14.65 2352 999 2.58 / 308.19 2 3
5 13 656.44 29 14.88 1200 518 3.09 / 308.71 2 4
6 8 0.28 165 15.08 319 794 3.89 / 309.50 2 9
Average= 3.40
(KJ/cycle)

Cycle 89 GMT 2/ 6/2023 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 29 15.02 481 210 0.21 / 301.75 2 3
2 7 2004.12 33 14.65 2849 1377 1.59 / 303.13 2 2
3 13 1596.68 29 14.67 2368 1007 2.59 / 304.14 2 3
4 13 651.40 29 14.90 1183 511 3.11 / 304.65 2 4
5 8 0.20 165 15.09 320 797 3.90 / 305.45 2 5
6 14 0.20 35 15.07 320 169 4.07 / 305.62 2 6
Average= 3.40
(KJ/cycle)

Cycle 88 GMT 23/ 5/2023 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 29 15.01 497 216 0.22 / 297.68 2 3
2 7 2002.96 33 14.63 2854 1378 1.59 / 299.06 2 2
3 13 1579.88 29 14.65 2359 1002 2.60 / 300.06 2 3
4 13 638.48 29 14.89 1191 514 3.11 / 300.57 2 3
5 8 0.12 165 15.08 323 804 3.91 / 301.38 2 10
6 14 0.12 35 15.06 318 168 4.08 / 301.54 2 4
Average= 3.39
(KJ/cycle)

Cycle 87 GMT 13/ 5/2023 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 29 15.01 479 209 0.21 / 293.75 2 3
2 7 2003.92 33 14.64 2833 1369 1.58 / 295.12 2 2
3 13 1585.76 29 14.66 2336 993 2.57 / 296.12 2 3
4 13 619.84 29 14.89 1147 495 3.07 / 296.61 2 3
5 13 18.32 10 15.12 371 56 3.12 / 296.67 2 2
6 8 0.08 165 15.07 320 796 3.92 / 297.46 2 7
Average= 3.38
(KJ/cycle)

Cycle 86 GMT 4/ 5/2023 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 28 15.02 494 208 0.21 / 289.64 2 3
2 3 1034.40 1 15.06 1744 26 0.23 / 289.67 2 3
3 7 2002.76 33 14.66 2841 1374 1.61 / 291.04 2 2
4 13 1599.84 29 14.66 2349 999 2.61 / 292.04 2 3
5 13 663.76 29 14.89 1203 519 3.13 / 292.56 2 4
6 8 0.24 165 15.09 326 812 3.94 / 293.37 2 4
7 14 0.24 35 15.06 324 171 4.11 / 293.55 2 8
Average= 3.37
(KJ/cycle)

Cycle 85 GMT 24/ 4/2023 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 29 15.02 475 207 0.21 / 285.73 2 3
2 3 961.36 -1 15.45 0 0 0.00 / 285.73 2 3
3 7 2006.68 33 14.66 2843 1375 1.58 / 287.11 2 2
4 13 1590.00 29 14.67 2330 991 2.57 / 288.10 2 3
5 13 658.80 29 14.90 1194 516 3.09 / 288.61 2 4
6 13 43.08 5 15.14 408 31 3.12 / 288.64 2 3
7 8 -0.12 165 15.09 318 792 3.91 / 289.44 2 3
Average= 3.37
(KJ/cycle)

Cycle 84 GMT 14/ 4/2023 5:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 29 15.02 495 216 0.22 / 281.61 2 2
2 7 2007.44 33 14.66 2860 1384 1.60 / 283.00 2 2
3 13 1589.76 29 14.67 2345 998 2.60 / 283.99 2 3
4 13 653.16 29 14.90 1199 518 3.11 / 284.51 2 3
5 13 40.16 5 15.13 419 32 3.15 / 284.54 2 4
6 8 0.24 165 15.08 326 811 3.96 / 285.35 2 9
7 14 0.24 35 15.07 323 170 4.13 / 285.52 2 10
Average= 3.36
(KJ/cycle)

Cycle 83 GMT 4/ 4/2023 7:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 29 15.03 488 213 0.21 / 277.62 2 3
2 7 2008.92 34 14.65 2852 1421 1.63 / 279.04 2 2
3 13 1595.28 29 14.66 2336 993 2.63 / 280.03 2 3
4 13 656.44 29 14.90 1203 520 3.15 / 280.55 2 3
5 13 47.44 5 15.14 426 32 3.18 / 280.58 2 3
6 8 0.36 165 15.08 327 814 3.99 / 281.40 2 9
Average= 3.35
(KJ/cycle)

Cycle 82 GMT 25/ 3/2023 10: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 15.05 474 207 0.21 / 273.70 2 3
2 7 2003.64 33 14.65 2832 1369 1.58 / 275.07 2 2
3 13 1592.64 29 14.66 2336 993 2.57 / 276.06 2 3
4 13 659.04 29 14.89 1222 528 3.10 / 276.59 2 3
5 8 -0.04 165 15.09 327 814 3.91 / 277.40 2 4
Average= 3.34
(KJ/cycle)

Cycle 81 GMT 15/ 3/2023 12:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 29 15.04 497 217 0.22 / 269.68 2 2
2 7 2007.76 33 14.64 2839 1372 1.59 / 271.05 2 2
3 13 1585.16 29 14.66 2316 985 2.57 / 272.03 2 3
4 13 646.00 29 14.90 1170 506 3.08 / 272.54 2 4
5 8 -0.12 165 15.09 316 787 3.87 / 273.33 2 9
6 14 -0.12 35 15.08 317 167 4.03 / 273.49 2 7
Average= 3.34
(KJ/cycle)

Cycle 80 GMT 5/ 3/2023 14:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 29 15.05 486 212 0.21 / 265.77 2 3
2 7 2002.72 33 14.67 2839 1374 1.59 / 267.15 2 2
3 13 1586.80 29 14.68 2329 992 2.58 / 268.14 2 3
4 13 656.00 29 14.90 1187 513 3.09 / 268.65 2 3
5 8 0.24 165 15.11 325 810 3.90 / 269.46 2 11
Average= 3.33
(KJ/cycle)

Cycle 79 GMT 23/ 2/2023 16:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 15.04 483 211 0.21 / 261.85 2 2
2 7 2007.44 33 14.67 2845 1377 1.59 / 263.23 2 2
3 13 1594.64 29 14.68 2332 993 2.58 / 264.22 2 3
4 13 653.20 29 14.90 1192 515 3.10 / 264.74 2 4
5 8 -0.12 165 15.11 329 820 3.92 / 265.56 2 7
Average= 3.32
(KJ/cycle)

Cycle 78 GMT 13/ 2/2023 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 29 15.06 486 212 0.21 / 257.93 2 3
2 7 2003.20 33 14.67 2840 1375 1.59 / 259.31 2 2
3 13 1600.64 29 14.68 2351 1001 2.59 / 260.31 2 3
4 13 656.84 29 14.91 1199 518 3.11 / 260.83 2 3
5 8 0.16 165 15.11 328 818 3.92 / 261.64 2 5
Average= 3.31
(KJ/cycle)

Cycle 77 GMT 3/ 2/2023 21:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 29 15.02 498 217 0.22 / 253.85 2 3
2 7 2002.60 33 14.67 2845 1377 1.59 / 255.23 2 2
3 13 1578.36 29 14.69 2324 990 2.58 / 256.22 2 3
4 13 621.16 29 14.94 1156 501 3.09 / 256.72 2 4
5 8 0.12 165 15.12 330 823 3.91 / 257.55 2 9
6 14 0.12 35 15.10 328 173 4.08 / 257.72 3 10
Average= 3.30
(KJ/cycle)

Cycle 76 GMT 24/ 1/2023 23:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 28 15.02 487 205 0.20 / 249.96 2 3
2 7 2008.60 33 14.67 2838 1374 1.58 / 251.33 2 2
3 13 1591.08 29 14.68 2314 985 2.56 / 252.32 2 3
4 13 659.28 29 14.92 1187 514 3.08 / 252.83 2 3
5 8 0.28 165 15.12 324 808 3.89 / 253.64 2 9
Average= 3.29
(KJ/cycle)

Cycle 75 GMT 15/ 1/2023 1: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 27 15.05 468 190 0.19 / 246.01 2 3
2 10 1005.52 2 14.97 1687 51 0.24 / 246.06 2 2
3 7 2006.68 33 14.67 2844 1377 1.62 / 247.44 2 2
4 13 1594.56 29 14.68 2339 996 2.61 / 248.43 2 3
5 13 660.72 29 14.92 1191 515 3.13 / 248.95 2 3
6 8 -0.04 165 15.11 322 803 3.93 / 249.75 2 5
Average= 3.29
(KJ/cycle)

Cycle 74 GMT 5/ 1/2023 3:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 18 15.06 490 133 0.13 / 241.89 2 2
2 10 1019.36 5 14.86 1703 127 0.26 / 242.02 2 2
3 10 1069.32 3 14.89 1752 78 0.34 / 242.09 2 2
4 3 1119.20 3 14.92 1836 82 0.42 / 242.18 2 3
5 7 2006.28 34 14.67 2843 1418 1.84 / 243.59 2 3
6 13 1585.60 29 14.68 2314 985 2.82 / 244.58 2 3
7 13 529.84 29 14.97 1018 442 3.26 / 245.02 2 4
8 8 0.04 165 15.12 320 798 4.06 / 245.82 2 5
Average= 3.28
(KJ/cycle)

Cycle 73 GMT 26/12/2022 5:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 18 15.12 497 135 0.14 / 238.06 2 3
2 7 2010.40 33 14.68 2847 1379 1.51 / 239.44 2 2
3 13 1594.72 29 14.68 2331 992 2.51 / 240.43 2 3
4 13 659.20 29 14.92 1189 514 3.02 / 240.94 2 5
5 8 0.00 165 15.13 326 814 3.84 / 241.76 2 5
Average= 3.27
(KJ/cycle)

Cycle 72

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 18 15.12 503 137 0.14 / 235.05 2 3
2 3 1016.24 1 15.16 1730 26 0.16 / 235.07 2 2
3 7 2003.16 33 14.66 2832 1370 1.53 / 236.44 2 2
4 13 1582.56 29 14.68 2304 981 2.51 / 237.42 2 3
5 13 627.56 29 14.94 1151 499 3.01 / 237.92 2 4
Average= 3.26
(KJ/cycle)

Cycle 71

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 17 15.13 497 128 0.13 / 232.04 2 3
2 3 1020.56 1 15.14 1716 26 0.15 / 232.06 2 2
3 7 2004.00 33 14.66 2834 1371 1.52 / 233.43 2 2
4 13 1571.36 29 14.70 2298 980 2.50 / 234.41 2 3
5 13 624.80 29 14.95 1146 497 3.00 / 234.91 2 4
Average= 3.26
(KJ/cycle)

Cycle 70

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 16 15.13 490 119 0.12 / 229.06 2 3
2 10 1021.84 2 14.99 1713 51 0.17 / 229.11 2 3
3 7 2007.20 33 14.66 2835 1372 1.54 / 230.48 2 2
4 13 1585.08 29 14.69 2320 988 2.53 / 231.47 2 3
5 13 517.36 29 14.99 1009 439 2.97 / 231.91 2 3
Average= 3.27
(KJ/cycle)

Cycle 69

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 18 15.13 496 135 0.14 / 226.16 2 3
2 3 945.48 -2 15.48 0 0 0.00 / 226.16 2 3
3 7 2002.08 34 14.66 2824 1408 1.54 / 227.57 2 2
4 13 1451.92 29 14.72 2154 919 2.46 / 228.49 2 3
5 13 547.16 29 14.96 1047 454 2.92 / 228.94 2 3
Average= 3.27
(KJ/cycle)

Cycle 68

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 18 15.13 500 136 0.14 / 223.18 2 3
2 7 2002.88 33 14.66 2824 1366 1.50 / 224.55 2 2
3 13 1576.00 29 14.69 2301 980 2.48 / 225.53 2 3
4 13 615.32 29 14.96 1134 492 2.97 / 226.02 2 4
Average= 3.28
(KJ/cycle)

Cycle 67

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 18 15.14 493 134 0.13 / 220.18 2 3
2 7 2008.48 33 14.66 2845 1376 1.51 / 221.56 2 2
3 13 1585.36 29 14.68 2322 989 2.50 / 222.54 2 3
4 13 639.52 29 14.94 1162 503 3.00 / 223.05 2 4
Average= 3.28
(KJ/cycle)

Cycle 66

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 18 15.13 487 133 0.13 / 217.18 2 3
2 7 2003.12 33 14.67 2832 1371 1.50 / 218.55 2 2
3 13 1586.84 29 14.69 2318 987 2.49 / 219.54 2 3
4 13 643.24 29 14.94 1172 508 3.00 / 220.05 2 4
Average= 3.28
(KJ/cycle)

Cycle 65

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 18 15.13 491 134 0.13 / 214.28 2 3
2 7 2011.36 33 14.65 2853 1379 1.51 / 215.66 2 2
3 13 1468.32 29 14.72 2173 928 2.44 / 216.59 2 3
4 13 554.16 29 14.97 1057 459 2.90 / 217.05 2 3
Average= 3.29
(KJ/cycle)

Cycle 64

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 18 15.15 495 135 0.13 / 211.23 2 3
2 7 2010.12 34 14.65 2846 1418 1.55 / 212.65 2 2
3 13 1588.20 29 14.69 2330 993 2.55 / 213.64 2 3
4 13 636.52 29 14.95 1162 504 3.05 / 214.15 2 5
Average= 3.29
(KJ/cycle)

Cycle 63

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 18 15.15 485 132 0.13 / 208.34 2 2
2 7 2009.24 33 14.67 2841 1375 1.51 / 209.72 2 2
3 13 1454.12 29 14.74 2161 924 2.43 / 210.64 2 3
4 13 549.20 29 14.99 1045 454 2.89 / 211.10 2 5
Average= 3.30
(KJ/cycle)

Cycle 62

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 18 15.15 481 131 0.13 / 205.36 2 3
2 7 2007.44 33 14.66 2838 1373 1.50 / 206.73 2 2
3 13 1571.24 29 14.72 2306 984 2.49 / 207.72 2 3
4 13 619.56 29 14.97 1140 495 2.98 / 208.21 2 4
Average= 3.30
(KJ/cycle)

Cycle 61

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 18 15.14 490 134 0.13 / 202.37 2 3
2 7 2004.12 34 14.68 2830 1413 1.55 / 203.78 2 2
3 13 1464.80 29 14.74 2169 927 2.47 / 204.71 2 3
4 13 667.24 29 14.94 1200 520 2.99 / 205.23 2 4
Average= 3.31
(KJ/cycle)

Cycle 60

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 18 15.15 500 136 0.14 / 199.41 2 3
2 3 1020.52 1 15.17 1728 26 0.16 / 199.43 2 2
3 7 2008.12 33 14.67 2837 1373 1.54 / 200.81 2 2
4 13 1583.28 29 14.71 2324 991 2.53 / 201.80 2 3
5 13 519.48 29 15.01 1007 438 2.97 / 202.24 2 3
Average= 3.32
(KJ/cycle)

Cycle 59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 18 15.16 491 134 0.13 / 196.37 2 3
2 7 2010.08 34 14.66 2834 1413 1.55 / 197.78 2 2
3 13 1582.84 29 14.71 2310 985 2.53 / 198.77 2 3
4 13 634.96 29 14.97 1160 504 3.04 / 199.27 2 5
Average= 3.32
(KJ/cycle)

Cycle 58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 18 15.17 491 134 0.13 / 193.36 2 3
2 7 2009.16 33 14.68 2842 1377 1.51 / 194.74 2 2
3 13 1596.12 29 14.71 2328 993 2.50 / 195.73 2 3
4 13 639.04 29 14.97 1161 504 3.01 / 196.23 2 4
Average= 3.33
(KJ/cycle)

Cycle 57

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 16 15.17 495 120 0.12 / 190.30 2 3
2 10 1033.68 2 15.02 1714 51 0.17 / 190.36 2 3
3 7 2002.84 33 14.69 2836 1375 1.55 / 191.73 2 2
4 13 1586.20 29 14.72 2319 990 2.54 / 192.72 2 3
5 13 640.36 29 14.98 1167 507 3.04 / 193.23 2 4
Average= 3.33
(KJ/cycle)

Cycle 56

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 17 15.16 495 128 0.13 / 187.31 2 3
2 3 955.56 -1 15.50 0 0 0.00 / 187.31 2 3
3 7 2004.08 33 14.70 2840 1378 1.51 / 188.69 2 2
4 13 1579.96 29 14.73 2312 988 2.49 / 189.68 2 2
5 13 638.52 29 14.99 1166 507 3.00 / 190.18 2 3
Average= 3.34
(KJ/cycle)

Cycle 55

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 16 15.17 488 118 0.12 / 184.26 2 3
2 10 1003.76 2 15.03 1695 51 0.17 / 184.31 2 3
3 3 979.88 -1 15.51 0 0 0.05 / 184.31 2 3
4 7 2008.48 33 14.70 2838 1377 1.55 / 185.69 2 2
5 13 1585.44 29 14.72 2313 987 2.53 / 186.68 2 3
6 13 643.56 29 14.98 1167 507 3.04 / 187.18 2 5
Average= 3.34
(KJ/cycle)

Cycle 54

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 18 15.17 493 135 0.13 / 181.35 2 3
2 3 951.60 -1 15.51 0 0 0.00 / 181.35 2 3
3 3 981.48 -1 15.53 0 0 0.00 / 181.35 2 3
4 7 2002.84 33 14.69 2839 1376 1.51 / 182.72 2 2
5 13 1442.60 29 14.77 2144 918 2.43 / 183.64 2 3
6 13 632.16 29 14.99 1156 503 2.93 / 184.14 2 3
Average= 3.35
(KJ/cycle)

Cycle 53

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 18 15.18 492 134 0.13 / 178.31 2 3
2 7 2002.88 34 14.68 2831 1413 1.55 / 179.72 2 2
3 13 1581.32 29 14.73 2317 990 2.54 / 180.71 2 3
4 13 632.44 29 14.98 1149 499 3.04 / 181.21 2 4
Average= 3.36
(KJ/cycle)

Cycle 52

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 19 15.17 499 144 0.14 / 175.32 2 3
2 3 965.28 -1 15.52 0 0 0.00 / 175.32 2 3
3 7 2004.92 33 14.69 2836 1375 1.52 / 176.69 2 2
4 13 1578.84 29 14.72 2312 987 2.51 / 177.68 2 3
5 13 626.92 29 14.99 1146 498 3.00 / 178.18 2 4
Average= 3.36
(KJ/cycle)

Cycle 51

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 28 15.16 498 211 0.21 / 172.36 2 3
2 3 575.00 -13 15.52 0 0 0.00 / 172.36 2 3
3 7 2008.56 33 14.68 2847 1379 1.59 / 173.74 2 3
4 13 1443.84 29 14.77 2142 917 2.51 / 174.66 2 3
5 13 650.08 29 14.98 1177 511 3.02 / 175.17 2 4
Average= 3.37
(KJ/cycle)

Cycle 50

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 28 15.12 487 206 0.21 / 169.28 2 3
2 7 2009.08 33 14.71 2838 1378 1.58 / 170.66 2 2
3 13 1457.12 29 14.78 2160 926 2.51 / 171.59 2 3
4 13 690.36 29 14.99 1229 534 3.04 / 172.12 2 4
5 13 48.80 5 15.23 416 32 3.08 / 172.15 2 4
Average= 3.38
(KJ/cycle)

Cycle 49 GMT 2/ 5/2022 16:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 28 15.12 486 206 0.21 / 165.38 2 3
2 7 2006.80 33 14.71 2841 1379 1.58 / 166.76 2 2
3 13 1587.76 29 14.74 2319 991 2.58 / 167.75 2 3
4 13 642.72 29 15.00 1169 509 3.08 / 168.26 2 3
5 8 0.48 165 15.18 327 819 3.90 / 169.08 2 4
Average= 3.38
(KJ/cycle)

Cycle 48 GMT 22/ 4/2022 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 28 15.13 486 206 0.21 / 161.49 2 3
2 7 2003.56 33 14.71 2838 1378 1.58 / 162.87 2 3
3 13 1572.36 29 14.75 2299 983 2.57 / 163.85 2 3
4 13 631.76 29 15.01 1155 503 3.07 / 164.36 2 4
5 8 0.04 165 15.18 326 817 3.89 / 165.17 2 8
Average= 3.37
(KJ/cycle)

Cycle 47 GMT 12/ 4/2022 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 28 15.12 491 208 0.21 / 157.61 2 3
2 7 2009.68 33 14.70 2836 1376 1.58 / 158.98 2 2
3 13 1599.16 29 14.73 2326 994 2.58 / 159.98 2 2
4 13 635.80 29 14.99 1155 502 3.08 / 160.48 2 5
5 8 0.12 165 15.18 323 809 3.89 / 161.29 2 7
Average= 3.36
(KJ/cycle)

Cycle 46 GMT 2/ 4/2022 22:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 15.13 481 204 0.20 / 153.79 2 3
2 7 2002.96 33 14.70 2828 1372 1.58 / 155.17 2 2
3 13 1581.28 29 14.75 2312 989 2.56 / 156.16 2 3
4 13 502.92 29 15.06 987 431 3.00 / 156.59 2 4
5 8 0.20 165 15.19 324 812 3.81 / 157.40 2 8
Average= 3.35
(KJ/cycle)

Cycle 45 GMT 24/ 3/2022 1:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 28 15.14 486 206 0.21 / 149.84 2 3
2 7 2011.04 34 14.70 2832 1415 1.62 / 151.26 2 3
3 13 1600.84 29 14.74 2334 998 2.62 / 152.26 2 3
4 13 614.44 29 15.01 1131 492 3.11 / 152.75 2 4
5 13 51.04 5 15.24 413 31 3.14 / 152.78 2 4
6 8 0.00 165 15.19 323 810 3.95 / 153.59 2 8
Average= 3.34
(KJ/cycle)

Cycle 44 GMT 14/ 3/2022 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 28 15.14 474 201 0.20 / 145.93 2 3
2 7 2009.20 33 14.72 2833 1376 1.58 / 147.31 2 2
3 13 1587.88 29 14.75 2316 991 2.57 / 148.30 2 3
4 13 615.88 29 15.03 1130 493 3.06 / 148.79 2 4
5 13 44.08 5 15.26 402 31 3.09 / 148.82 2 4
6 8 0.20 165 15.21 324 813 3.90 / 149.64 2 5
Average= 3.33
(KJ/cycle)

Cycle 43 GMT 4/ 3/2022 5:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 28 15.14 479 203 0.20 / 141.90 2 3
2 7 2008.44 33 14.72 2835 1377 1.58 / 143.28 2 2
3 13 1597.80 29 14.76 2322 994 2.57 / 144.27 2 3
4 13 633.64 29 15.01 1153 502 3.08 / 144.77 2 3
5 13 19.96 29 15.24 355 157 3.23 / 144.93 2 3
6 8 0.12 165 15.19 321 805 4.04 / 145.73 2 8
Average= 3.31
(KJ/cycle)

Cycle 42 GMT 22/ 2/2022 8: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 28 15.14 486 206 0.21 / 137.86 2 3
2 7 2004.92 33 14.71 2834 1376 1.58 / 139.24 2 2
3 13 1585.92 29 14.76 2321 993 2.58 / 140.23 2 3
4 13 625.64 29 15.03 1143 498 3.07 / 140.73 2 4
5 13 20.36 29 15.23 357 158 3.23 / 140.89 2 3
6 8 0.00 165 15.19 323 810 4.04 / 141.70 2 7
Average= 3.30
(KJ/cycle)

Cycle 41 GMT 12/ 2/2022 10:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 15.14 478 203 0.20 / 133.80 2 2
2 7 2001.92 33 14.73 2836 1379 1.58 / 135.18 2 2
3 13 1581.80 29 14.77 2312 990 2.57 / 136.17 2 3
4 13 646.96 29 15.03 1173 511 3.08 / 136.68 2 4
5 13 23.32 29 15.24 364 161 3.24 / 136.84 2 3
6 8 -0.04 165 15.20 324 813 4.06 / 137.66 2 7
Average= 3.28
(KJ/cycle)

Cycle 40 GMT 2/ 2/2022 12:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 28 15.13 492 208 0.21 / 129.74 2 3
2 7 2007.68 33 14.73 2840 1380 1.59 / 131.12 2 2
3 13 1587.64 29 14.78 2317 993 2.58 / 132.12 2 3
4 13 661.48 29 15.03 1187 517 3.10 / 132.64 2 3
5 13 16.80 29 15.24 355 157 3.26 / 132.79 2 3
6 8 0.32 165 15.20 322 808 4.06 / 133.60 2 6
Average= 3.26
(KJ/cycle)

Cycle 39 GMT 23/ 1/2022 14:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 26 15.14 489 192 0.19 / 125.79 2 3
2 10 1008.24 2 15.05 1691 51 0.24 / 125.84 2 2
3 7 2006.08 33 14.71 2846 1382 1.62 / 127.22 2 2
4 13 1568.48 29 14.77 2298 984 2.61 / 128.21 2 3
5 13 628.64 29 15.04 1151 502 3.11 / 128.71 2 3
6 8 0.08 165 15.22 329 826 3.94 / 129.54 2 5
Average= 3.24
(KJ/cycle)

Cycle 38 GMT 13/ 1/2022 16:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 15 15.14 502 114 0.11 / 121.62 2 2
2 10 1052.92 6 14.93 1752 157 0.27 / 121.78 2 2
3 10 1112.04 4 14.95 1831 109 0.38 / 121.89 2 2
4 10 1140.96 2 15.00 1846 55 0.44 / 121.94 2 2
5 3 1114.20 3 15.03 1830 83 0.52 / 122.02 2 3
6 7 2008.80 33 14.71 2840 1379 1.90 / 123.40 2 3
7 13 1456.40 29 14.80 2160 927 2.82 / 124.33 2 3
8 13 541.28 29 15.06 1039 454 3.28 / 124.78 2 3
9 8 0.16 165 15.21 325 816 4.09 / 125.60 2 5
Average= 3.22
(KJ/cycle)

Cycle 37 GMT 3/ 1/2022 18:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 15 15.21 502 115 0.11 / 117.79 2 3
2 7 2005.48 33 14.73 2836 1379 1.49 / 119.17 2 2
3 13 1575.28 29 14.78 2302 987 2.48 / 120.16 2 3
4 13 619.20 29 15.05 1136 496 2.98 / 120.65 2 4
5 13 18.64 5 15.29 375 29 3.00 / 120.68 2 3
6 8 0.16 165 15.22 328 824 3.83 / 121.50 2 7
Average= 3.20
(KJ/cycle)

Cycle 36

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 17 15.21 496 128 0.13 / 114.82 2 3
2 3 938.96 -2 15.54 0 0 0.00 / 114.82 2 3
3 7 2002.96 33 14.72 2829 1374 1.50 / 116.19 2 2
4 13 1579.16 29 14.77 2313 991 2.49 / 117.18 2 3
5 13 619.60 29 15.04 1138 496 2.99 / 117.68 2 3
Average= 3.18
(KJ/cycle)

Cycle 35

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 17 15.21 501 130 0.13 / 111.79 2 3
2 7 2010.64 33 14.72 2845 1382 1.51 / 113.17 2 2
3 13 1602.28 29 14.76 2338 1001 2.51 / 114.18 2 2
4 13 652.88 29 15.02 1175 512 3.02 / 114.69 2 4
Average= 3.19
(KJ/cycle)

Cycle 34

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 17 15.22 492 127 0.13 / 108.78 2 3
2 7 2006.08 33 14.74 2837 1380 1.51 / 110.16 2 3
3 13 1590.40 29 14.79 2320 995 2.50 / 111.15 2 3
4 13 643.00 29 15.05 1170 511 3.01 / 111.66 2 3
Average= 3.19
(KJ/cycle)

Cycle 33

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 16 15.22 494 120 0.12 / 105.75 2 3
2 3 1020.80 1 15.24 1715 26 0.15 / 105.78 2 2
3 7 2004.48 33 14.74 2839 1381 1.53 / 107.16 2 2
4 13 1575.60 29 14.78 2311 991 2.52 / 108.15 2 3
5 13 628.96 29 15.04 1155 504 3.02 / 108.65 2 4
Average= 3.20
(KJ/cycle)

Cycle 32

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 16 15.22 488 119 0.12 / 102.85 2 3
2 7 2008.00 33 14.73 2845 1383 1.50 / 104.23 2 2
3 13 1464.64 29 14.82 2164 930 2.43 / 105.16 2 3
4 13 569.40 29 15.07 1076 470 2.90 / 105.63 2 4
Average= 3.20
(KJ/cycle)

Cycle 31

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 16 15.24 488 119 0.12 / 99.89 2 3
2 7 2007.56 33 14.74 2831 1377 1.50 / 101.26 2 2
3 13 1462.20 29 14.82 2179 936 2.43 / 102.20 2 3
4 13 682.72 29 15.03 1210 527 2.96 / 102.73 2 3
Average= 3.21
(KJ/cycle)

Cycle 30

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 16 15.23 495 121 0.12 / 96.91 2 3
2 7 2004.76 33 14.75 2841 1383 1.50 / 98.29 2 2
3 13 1566.24 29 14.81 2294 985 2.49 / 99.27 2 3
4 13 612.72 29 15.08 1128 493 2.98 / 99.77 2 4
Average= 3.22
(KJ/cycle)

Cycle 29

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 15 15.23 486 111 0.11 / 93.87 2 3
2 10 1005.76 2 15.09 1692 51 0.16 / 93.92 2 3
3 3 977.72 -1 15.57 0 0 0.05 / 93.92 2 3
4 7 2008.00 33 14.76 2844 1385 1.55 / 95.30 2 2
5 13 1473.68 29 14.84 2184 940 2.49 / 96.24 2 3
6 13 703.04 29 15.04 1241 541 3.03 / 96.78 2 3
Average= 3.23
(KJ/cycle)

Cycle 28

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 16 15.23 495 121 0.12 / 90.92 2 3
2 3 956.56 -1 15.58 0 0 0.00 / 90.92 2 3
3 7 2008.12 33 14.74 2840 1381 1.50 / 92.30 2 2
4 13 1458.04 29 14.83 2161 929 2.43 / 93.23 2 3
5 13 671.20 29 15.03 1205 525 2.96 / 93.76 2 4
Average= 3.23
(KJ/cycle)

Cycle 27

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 16 15.25 485 118 0.12 / 87.91 2 3
2 7 2006.40 33 14.76 2835 1381 1.50 / 89.30 2 2
3 13 1581.44 29 14.81 2319 996 2.50 / 90.29 2 3
4 13 639.44 29 15.06 1163 508 3.00 / 90.80 2 4
Average= 3.24
(KJ/cycle)

Cycle 26

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 16 15.23 485 118 0.12 / 84.91 2 3
2 7 2002.20 33 14.76 2826 1376 1.49 / 86.29 2 2
3 13 1594.12 29 14.82 2324 999 2.49 / 87.28 2 3
4 13 647.04 29 15.07 1172 512 3.01 / 87.80 2 4
Average= 3.25
(KJ/cycle)

Cycle 25

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 16 15.24 489 119 0.12 / 81.90 2 3
2 3 1017.88 1 15.27 1709 26 0.15 / 81.93 2 2
3 7 2007.08 33 14.75 2829 1377 1.52 / 83.31 2 3
4 13 1568.48 29 14.81 2298 987 2.51 / 84.29 2 3
5 13 623.92 29 15.07 1139 498 3.01 / 84.79 2 3
Average= 3.26
(KJ/cycle)

Cycle 24

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 16 15.23 495 121 0.12 / 79.02 2 3
2 7 2001.84 33 14.77 2832 1380 1.50 / 80.40 2 2
3 13 1456.12 29 14.85 2162 931 2.43 / 81.33 2 3
4 13 541.16 29 15.09 1039 455 2.89 / 81.78 2 4
Average= 3.27
(KJ/cycle)

Cycle 23

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 15 15.25 490 112 0.11 / 76.01 2 3
2 3 1040.32 1 15.21 1732 26 0.14 / 76.03 2 2
3 7 2003.12 33 14.75 2836 1380 1.52 / 77.41 2 2
4 13 1575.28 29 14.82 2314 995 2.51 / 78.41 2 3
5 13 606.72 29 15.08 1121 490 3.00 / 78.90 2 4
Average= 3.29
(KJ/cycle)

Cycle 22

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 15 15.25 488 112 0.11 / 73.10 2 3
2 3 1022.08 1 15.26 1706 26 0.14 / 73.13 2 3
3 7 2007.68 33 14.76 2842 1384 1.52 / 74.51 2 2
4 13 1449.80 29 14.86 2157 930 2.45 / 75.44 2 3
5 13 532.56 29 15.10 1035 453 2.90 / 75.89 2 3
Average= 3.30
(KJ/cycle)

Cycle 21

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 16 15.25 493 120 0.12 / 70.12 2 3
2 3 950.84 -1 15.59 0 0 0.00 / 70.12 2 3
3 3 978.72 -1 15.61 0 0 0.00 / 70.12 2 3
4 7 2002.08 33 14.76 2834 1380 1.50 / 71.50 2 2
5 13 1584.32 29 14.82 2312 994 2.49 / 72.50 2 3
6 13 610.28 29 15.07 1127 493 2.99 / 72.99 2 3
Average= 3.32
(KJ/cycle)

Cycle 20

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 16 15.27 497 121 0.12 / 67.17 2 3
2 7 2002.04 33 14.77 2835 1382 1.50 / 68.56 2 2
3 13 1445.24 29 14.86 2149 926 2.43 / 69.48 2 3
4 13 660.44 29 15.06 1190 520 2.95 / 70.00 2 4
Average= 3.33
(KJ/cycle)

Cycle 19

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 16 15.25 493 120 0.12 / 64.21 2 3
2 3 1020.68 1 15.28 1723 26 0.15 / 64.24 2 3
3 7 2006.56 33 14.78 2838 1384 1.53 / 65.62 2 2
4 13 1581.16 29 14.85 2318 998 2.53 / 66.62 2 3
5 13 501.28 29 15.14 987 433 2.96 / 67.05 2 4
Average= 3.35
(KJ/cycle)

Cycle 18

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 16 15.25 490 120 0.12 / 61.20 2 3
2 7 2007.12 33 14.78 2840 1385 1.50 / 62.58 2 2
3 13 1595.16 29 14.83 2323 999 2.50 / 63.58 2 3
4 13 634.32 29 15.09 1159 507 3.01 / 64.09 2 3
Average= 3.37
(KJ/cycle)

Cycle 17

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 17 15.24 488 126 0.13 / 58.26 2 3
2 3 943.36 -2 15.58 0 0 0.00 / 58.26 2 3
3 7 2007.32 33 14.78 2837 1384 1.51 / 59.64 2 2
4 13 1439.92 29 14.86 2139 922 2.43 / 60.56 2 3
5 13 659.76 29 15.05 1184 517 2.95 / 61.08 2 4
Average= 3.39
(KJ/cycle)

Cycle 16

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 26 15.25 487 193 0.19 / 55.24 2 3
2 3 633.68 -11 15.58 0 0 0.00 / 55.24 2 3
3 7 2005.68 33 14.78 2834 1382 1.58 / 56.63 2 2
4 13 1602.92 29 14.84 2328 1002 2.58 / 57.63 2 3
5 13 631.20 29 15.07 1148 502 3.08 / 58.13 2 3
Average= 3.42
(KJ/cycle)

Cycle 15

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 18 15.20 475 130 0.13 / 51.91 2 2
2 10 1082.36 4 14.99 1781 107 0.24 / 52.02 2 2
3 10 1118.64 2 15.03 1819 55 0.29 / 52.07 2 2
4 3 1133.16 4 15.04 1846 111 0.40 / 52.18 2 3
5 7 2003.76 33 14.78 2833 1382 1.78 / 53.56 2 2
6 13 1582.36 29 14.83 2306 992 2.78 / 54.55 2 3
7 13 622.20 29 15.08 1136 497 3.27 / 55.05 2 3
Average= 3.44
(KJ/cycle)

Cycle 14 GMT 21/ 5/2021 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 27 15.26 479 197 0.20 / 48.03 2 3
2 3 563.52 -13 15.58 0 0 0.00 / 48.03 2 3
3 3 978.20 -1 15.60 0 0 0.00 / 48.03 2 3
4 7 2002.28 33 14.79 2834 1383 1.58 / 49.41 2 2
5 13 1450.36 29 14.86 2150 927 2.51 / 50.34 2 3
6 13 534.76 29 15.11 1028 450 2.96 / 50.79 2 5
7 13 44.24 5 15.31 405 31 2.99 / 50.82 2 4
8 13 18.76 27 15.29 357 147 3.14 / 50.97 2 3
9 8 -0.16 165 15.25 322 810 3.95 / 51.78 2 4
Average= 3.45
(KJ/cycle)

Cycle 13

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 27 15.17 494 202 0.20 / 45.01 2 3
2 7 2003.44 33 14.80 2834 1384 1.59 / 46.40 2 2
3 13 1578.40 29 14.85 2308 994 2.58 / 47.39 2 3
4 13 518.20 29 15.12 1008 442 3.02 / 47.83 2 3
Average= 3.42
(KJ/cycle)

Cycle 12 GMT 1/ 5/2021 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 27 15.20 480 197 0.20 / 41.07 2 3
2 7 2003.80 33 14.79 2832 1382 1.58 / 42.45 2 2
3 13 1454.04 29 14.88 2154 929 2.51 / 43.38 2 3
4 13 521.08 29 15.11 1005 440 2.95 / 43.82 2 3
5 8 0.40 165 15.25 323 813 3.76 / 44.64 2 3
6 14 0.40 35 15.24 325 173 3.94 / 44.81 5 5
Average= 3.45
(KJ/cycle)

Cycle 11 GMT 21/ 4/2021 9:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 27 15.19 485 199 0.20 / 37.28 2 3
2 7 2009.80 33 14.81 2837 1387 1.59 / 38.67 2 2
3 13 1462.96 29 14.87 2160 931 2.52 / 39.60 2 3
4 13 536.96 29 15.12 1033 453 2.97 / 40.05 2 4
5 8 -0.08 165 15.26 326 821 3.79 / 40.88 2 7
Average= 3.41
(KJ/cycle)

Cycle 10 GMT 11/ 4/2021 11:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 27 15.20 485 199 0.20 / 33.56 2 3
2 7 2004.48 33 14.81 2839 1388 1.59 / 34.95 2 2
3 13 1440.40 28 14.88 2136 890 2.48 / 35.84 2 3
4 13 526.24 28 15.13 1016 430 2.91 / 36.27 2 4
5 8 0.44 165 15.25 324 815 3.72 / 37.08 2 4
Average= 3.37
(KJ/cycle)

Cycle 9 GMT 1/ 4/2021 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 27 15.21 477 196 0.20 / 29.78 2 3
2 7 2003.88 34 14.79 2824 1420 1.62 / 31.20 2 2
3 13 1444.76 28 14.88 2140 892 2.51 / 32.09 2 3
4 13 528.64 28 15.12 1018 431 2.94 / 32.52 2 4
5 13 48.48 5 15.31 406 31 2.97 / 32.55 2 4
6 8 0.00 165 15.27 321 809 3.78 / 33.36 2 6
Average= 3.34
(KJ/cycle)

Cycle 8 GMT 22/ 3/2021 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 27 15.20 476 195 0.20 / 25.92 2 3
2 3 1017.36 1 15.29 1699 26 0.22 / 25.95 2 2
3 7 2001.68 33 14.82 2825 1382 1.60 / 27.33 2 2
4 13 1574.72 28 14.87 2297 956 2.56 / 28.29 2 3
5 13 630.76 28 15.11 1149 486 3.05 / 28.77 2 3
6 8 0.00 165 15.28 322 812 3.86 / 29.58 2 5
Average= 3.29
(KJ/cycle)

Cycle 7 GMT 12/ 3/2021 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 27 15.20 483 198 0.20 / 22.07 2 2
2 3 1024.72 1 15.27 1690 26 0.22 / 22.10 2 2
3 7 2002.04 33 14.82 2828 1383 1.61 / 23.48 2 3
4 13 1571.64 28 14.86 2301 957 2.56 / 24.44 2 3
5 13 614.76 28 15.10 1127 476 3.04 / 24.92 2 3
6 8 0.04 165 15.27 322 811 3.85 / 25.73 2 7
Average= 3.22
(KJ/cycle)

Cycle 6 GMT 2/ 3/2021 19:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 26 15.21 477 189 0.19 / 18.41 2 2
2 10 1003.32 2 15.14 1665 50 0.24 / 18.46 2 3
3 3 978.52 -1 15.59 0 0 0.05 / 18.46 2 3
4 7 2003.48 39 14.77 2810 1619 1.86 / 20.08 2 2
5 13 1281.56 18 14.96 1947 524 2.38 / 20.60 2 3
6 13 714.92 18 15.10 1254 341 2.72 / 20.95 2 3
7 13 75.04 18 15.29 435 120 2.84 / 21.07 2 4
8 8 0.20 165 15.27 321 809 3.65 / 21.87 2 5
Average= 3.12
(KJ/cycle)

Cycle 5 GMT 20/ 2/2021 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 28 15.19 474 202 0.20 / 14.77 2 2
2 3 932.24 -2 15.57 0 0 0.00 / 14.77 2 2
3 7 2003.00 39 14.79 2809 1620 1.82 / 16.39 2 2
4 13 1408.24 18 14.95 2084 561 2.38 / 16.95 2 3
5 13 694.12 18 15.11 1228 334 2.72 / 17.29 2 3
6 13 123.08 18 15.28 492 135 2.85 / 17.42 2 3
7 8 -0.04 165 15.28 318 802 3.65 / 18.22 2 6
Average= 3.04
(KJ/cycle)

Cycle 4 GMT 10/ 2/2021 22:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 25 15.23 466 177 0.18 / 11.43 2 3
2 7 1524.36 38 14.93 2218 1258 1.44 / 12.69 2 2
3 13 1268.84 18 14.98 1919 517 1.95 / 13.20 2 3
4 13 541.24 18 15.16 1027 280 2.23 / 13.48 2 3
5 13 67.84 18 15.29 422 116 2.35 / 13.60 2 3
6 8 -0.12 165 15.26 318 801 3.15 / 14.40 2 5
7 14 -0.12 35 15.25 317 169 3.32 / 14.57 2 9
Average= 2.91
(KJ/cycle)

Cycle 3 GMT 9/ 2/2021 22:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 23 15.23 467 164 0.16 / 7.84 2 3
2 10 1034.52 2 15.12 1712 52 0.22 / 7.90 2 3
3 7 1517.24 74 14.84 2206 2423 2.64 / 10.32 2 3
4 13 120.92 18 15.29 487 134 2.77 / 10.45 2 3
5 8 0.04 165 15.28 316 797 3.57 / 11.25 2 7
Average= 2.81
(KJ/cycle)

Cycle 2 GMT 8/ 2/2021 22:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 30 15.28 475 218 0.22 / 4.32 2 2
2 3 803.48 -4 15.63 0 0 0.00 / 4.32 2 2
3 3 933.00 -1 15.66 0 0 0.00 / 4.32 2 2
4 7 1523.20 74 14.86 2210 2430 2.65 / 6.75 2 3
5 13 117.44 18 15.30 482 133 2.78 / 6.88 2 4
6 8 0.24 165 15.30 318 803 3.58 / 7.68 2 6
Average= 2.56
(KJ/cycle)

Cycle 1 GMT 7/ 2/2021 22:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 26 15.48 401 161 0.16 / 1.56 2 2
2 7 980.16 74 15.06 1548 1725 1.89 / 3.29 2 3
3 8 -0.24 165 15.36 319 808 2.70 / 4.10 2 7
Average= 2.05
(KJ/cycle)

Cycle 0 GMT 7/ 2/2021 12:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 74.88 25 15.64 330 129 0.13 / 0.13 2 2
2 7 89.40 74 15.59 347 400 0.53 / 0.53 2 2
3 8 0.20 240 15.55 234 873 1.40 / 1.40 2 8
Average= 1.40
(KJ/cycle)