SIO Argo Site:
Pump Diagnostics Page   



Serial= 8915 WMO= 7900798

Return

←PreviousNext→

Cycle 148 GMT 15/12/2024 3:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.44 28 14.97 467 196 0.20 / 575.83 2 2
2 7 2003.52 32 14.77 2960 1399 1.59 / 577.23 2 2
3 13 1581.44 31 14.74 2408 1100 2.70 / 578.33 2 3
4 13 606.00 31 14.90 1124 519 3.21 / 578.85 2 3
5 8 0.32 180 15.03 277 749 3.96 / 579.60 2 2
Average= 3.89
(KJ/cycle)

Cycle 147 GMT 5/12/2024 5:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 28 14.96 470 197 0.20 / 571.89 2 2
2 7 2006.72 33 14.76 2956 1440 1.64 / 573.33 2 2
3 13 1462.24 31 14.77 2243 1027 2.66 / 574.36 2 3
4 13 521.16 31 14.93 1013 469 3.13 / 574.83 2 3
5 8 -0.12 180 15.03 275 744 3.88 / 575.57 2 2
6 14 -0.12 15 15.02 277 62 3.94 / 575.64 2 2
Average= 3.89
(KJ/cycle)

Cycle 146 GMT 25/11/2024 7:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 14.96 460 193 0.19 / 568.03 2 2
2 7 2002.40 33 14.77 2947 1436 1.63 / 569.47 2 2
3 13 1449.20 31 14.77 2231 1022 2.65 / 570.49 2 3
4 13 512.96 31 14.93 1005 465 3.12 / 570.95 2 3
5 8 0.24 180 15.03 274 741 3.86 / 571.70 2 2
Average= 3.89
(KJ/cycle)

Cycle 145 GMT 15/11/2024 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 28 14.98 467 196 0.20 / 564.09 2 2
2 7 2002.00 32 14.77 2951 1395 1.59 / 565.48 2 2
3 13 1577.52 31 14.74 2395 1094 2.69 / 566.58 2 3
4 13 602.56 31 14.91 1122 519 3.20 / 567.10 2 3
5 8 0.24 180 15.03 274 741 3.94 / 567.84 2 3
Average= 3.89
(KJ/cycle)

Cycle 144 GMT 5/11/2024 12:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 28 14.96 470 197 0.20 / 560.12 2 2
2 7 2003.84 32 14.79 2948 1395 1.59 / 561.51 2 2
3 13 1598.36 31 14.76 2423 1109 2.70 / 562.62 2 3
4 13 634.00 31 14.90 1161 536 3.24 / 563.16 2 3
5 8 0.28 180 15.04 273 739 3.98 / 563.89 2 3
Average= 3.89
(KJ/cycle)

Cycle 143 GMT 26/10/2024 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 28 14.97 455 191 0.19 / 555.99 2 2
2 7 2009.88 32 14.77 2956 1397 1.59 / 557.38 2 2
3 13 1589.96 31 14.75 2406 1100 2.69 / 558.48 2 3
4 13 602.48 31 14.90 1119 517 3.20 / 559.00 2 3
5 13 19.80 25 15.06 284 107 3.31 / 559.11 2 2
6 8 0.20 180 15.02 277 749 4.06 / 559.86 2 2
7 14 0.20 15 15.00 277 62 4.12 / 559.92 2 3
Average= 3.89
(KJ/cycle)

Cycle 142 GMT 16/10/2024 17:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 28 14.97 457 192 0.19 / 552.04 2 2
2 7 2003.64 32 14.78 2942 1391 1.58 / 553.43 2 2
3 13 1583.56 31 14.75 2402 1098 2.68 / 554.53 2 4
4 13 621.88 31 14.91 1140 527 3.21 / 555.06 2 4
5 8 0.44 180 15.03 272 736 3.94 / 555.80 2 2
Average= 3.89
(KJ/cycle)

Cycle 141 GMT 6/10/2024 19:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 28 14.97 473 198 0.20 / 548.12 2 2
2 7 2004.32 32 14.77 2950 1394 1.59 / 549.51 2 2
3 13 1564.48 31 14.75 2373 1085 2.68 / 550.60 2 3
4 13 586.88 31 14.92 1097 507 3.18 / 551.10 2 3
5 8 -0.36 180 15.04 276 747 3.93 / 551.85 2 2
Average= 3.89
(KJ/cycle)

Cycle 140 GMT 26/ 9/2024 22:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 14.99 447 188 0.19 / 544.10 2 2
2 7 2007.36 33 14.78 2966 1447 1.63 / 545.55 2 2
3 13 1587.80 31 14.76 2410 1103 2.74 / 546.65 2 4
4 13 608.60 31 14.90 1125 520 3.26 / 547.17 2 4
5 8 0.12 180 15.03 277 749 4.01 / 547.92 2 2
Average= 3.89
(KJ/cycle)

Cycle 139 GMT 17/ 9/2024 0:43:10

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 14.97 453 190 0.19 / 540.21 2 2
2 7 2002.80 33 14.78 2956 1442 1.63 / 541.65 2 2
3 13 1462.12 31 14.78 2250 1031 2.66 / 542.68 2 3
4 13 527.76 31 14.94 1026 475 3.14 / 543.16 2 3
5 8 0.04 180 15.06 278 754 3.89 / 543.91 2 2
Average= 3.89
(KJ/cycle)

Cycle 138 GMT 7/ 9/2024 2:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 28 14.98 462 194 0.19 / 536.39 2 2
2 7 2003.84 32 14.78 2947 1394 1.59 / 537.78 2 3
3 13 1458.24 31 14.77 2242 1027 2.61 / 538.81 2 3
4 13 536.00 31 14.92 1030 476 3.09 / 539.28 2 4
5 8 0.20 180 15.03 273 739 3.83 / 540.02 2 2
Average= 3.89
(KJ/cycle)

Cycle 137 GMT 28/ 8/2024 5: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 28 14.97 463 194 0.19 / 532.36 2 2
2 7 2007.08 32 14.78 2963 1401 1.60 / 533.77 2 2
3 13 1592.08 31 14.75 2417 1105 2.70 / 534.87 2 3
4 13 589.60 31 14.92 1106 512 3.21 / 535.38 2 3
5 8 -0.16 180 15.04 276 747 3.96 / 536.13 2 2
6 14 -0.16 15 15.02 277 62 4.02 / 536.19 2 2
Average= 3.89
(KJ/cycle)

Cycle 136 GMT 18/ 8/2024 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 28 14.98 439 184 0.18 / 528.47 2 2
2 7 2006.56 32 14.77 2952 1395 1.58 / 529.86 2 3
3 13 1461.80 31 14.78 2245 1029 2.61 / 530.89 2 4
4 13 644.44 31 14.90 1175 543 3.15 / 531.43 2 3
5 8 0.00 180 15.03 272 736 3.89 / 532.17 2 2
Average= 3.88
(KJ/cycle)

Cycle 135 GMT 8/ 8/2024 10: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 28 14.97 471 197 0.20 / 524.53 2 2
2 7 2004.32 32 14.79 2953 1398 1.60 / 525.93 2 2
3 13 1586.72 31 14.75 2403 1099 2.69 / 527.02 2 3
4 13 617.84 31 14.91 1137 526 3.22 / 527.55 2 3
5 8 0.04 180 15.05 271 734 3.95 / 528.28 2 3
Average= 3.88
(KJ/cycle)

Cycle 134 GMT 29/ 7/2024 12:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 14.98 433 182 0.18 / 520.59 2 2
2 7 2003.00 32 14.80 2942 1393 1.57 / 521.98 2 2
3 13 1582.28 31 14.76 2400 1098 2.67 / 523.08 2 3
4 13 610.84 31 14.91 1126 520 3.19 / 523.60 2 3
5 8 0.40 180 15.04 270 731 3.92 / 524.33 2 2
Average= 3.88
(KJ/cycle)

Cycle 133 GMT 19/ 7/2024 14:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 28 14.98 472 198 0.20 / 516.77 2 2
2 7 2006.92 32 14.78 2956 1398 1.60 / 518.17 2 2
3 13 1465.04 31 14.78 2250 1031 2.63 / 519.20 2 3
4 13 519.20 31 14.94 1008 467 3.09 / 519.67 2 3
5 8 -0.04 180 15.04 272 736 3.83 / 520.41 2 4
Average= 3.88
(KJ/cycle)

Cycle 132 GMT 9/ 7/2024 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 28 14.99 457 192 0.19 / 512.78 2 2
2 7 2003.96 32 14.77 2950 1394 1.59 / 514.17 2 3
3 13 1574.16 31 14.75 2393 1094 2.68 / 515.27 2 3
4 13 593.56 31 14.92 1107 512 3.19 / 515.78 2 4
5 8 -0.08 180 15.04 272 736 3.93 / 516.51 2 2
6 14 -0.08 15 15.03 272 61 3.99 / 516.58 2 2
Average= 3.88
(KJ/cycle)

Cycle 131 GMT 29/ 6/2024 19:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 28 14.99 458 192 0.19 / 508.82 2 2
2 7 2003.96 32 14.79 2956 1399 1.59 / 510.22 2 2
3 13 1576.52 31 14.77 2396 1097 2.69 / 511.32 2 3
4 13 601.64 31 14.93 1120 518 3.21 / 511.84 2 3
5 8 0.32 180 15.05 277 750 3.96 / 512.59 2 6
Average= 3.88
(KJ/cycle)

Cycle 130 GMT 19/ 6/2024 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 28 14.98 446 187 0.19 / 505.01 2 2
2 7 2002.48 32 14.79 2936 1390 1.58 / 506.40 2 2
3 13 1452.80 31 14.79 2242 1028 2.60 / 507.42 2 4
4 13 524.00 31 14.94 1018 471 3.08 / 507.89 2 3
5 8 -0.20 180 15.05 271 734 3.81 / 508.63 2 2
Average= 3.88
(KJ/cycle)

Cycle 129 GMT 10/ 6/2024 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 28 14.98 465 195 0.20 / 501.06 2 2
2 7 2003.52 32 14.79 2951 1397 1.59 / 502.46 2 2
3 13 1572.28 31 14.76 2389 1093 2.68 / 503.55 2 3
4 13 599.12 31 14.93 1114 516 3.20 / 504.07 2 3
5 8 0.24 180 15.05 277 750 3.95 / 504.82 2 2
Average= 3.88
(KJ/cycle)

Cycle 128 GMT 31/ 5/2024 2:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 28 14.98 459 193 0.19 / 497.11 2 2
2 7 2003.36 32 14.79 2941 1392 1.58 / 498.50 2 2
3 13 1580.16 31 14.77 2406 1102 2.69 / 499.60 2 5
4 13 620.84 31 14.92 1143 529 3.21 / 500.13 2 3
5 8 0.08 180 15.05 272 737 3.95 / 500.87 2 4
Average= 3.88
(KJ/cycle)

Cycle 127 GMT 21/ 5/2024 5:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 28 14.99 458 192 0.19 / 493.12 2 2
2 7 2004.28 32 14.81 2940 1393 1.59 / 494.52 2 2
3 13 1585.68 31 14.78 2409 1104 2.69 / 495.62 2 3
4 13 614.84 31 14.93 1135 525 3.21 / 496.15 2 3
5 13 19.24 6 15.09 288 26 3.24 / 496.17 2 2
6 8 -0.08 180 15.04 275 744 3.99 / 496.92 2 2
Average= 3.88
(KJ/cycle)

Cycle 126 GMT 11/ 5/2024 7:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 28 14.98 439 184 0.18 / 489.25 2 2
2 7 2003.88 32 14.78 2939 1390 1.57 / 490.64 2 2
3 13 1451.60 31 14.79 2224 1020 2.59 / 491.66 2 5
4 13 635.68 31 14.91 1164 538 3.13 / 492.20 2 3
5 8 0.04 180 15.05 271 734 3.87 / 492.93 2 2
Average= 3.88
(KJ/cycle)

Cycle 125 GMT 1/ 5/2024 10:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 28 14.99 447 188 0.19 / 485.37 2 2
2 7 2003.72 32 14.78 2958 1399 1.59 / 486.77 2 2
3 13 1456.96 31 14.78 2240 1026 2.61 / 487.80 2 3
4 13 641.32 31 14.90 1167 539 3.15 / 488.33 2 4
5 8 -0.12 180 15.04 270 731 3.88 / 489.07 2 4
Average= 3.88
(KJ/cycle)

Cycle 124 GMT 21/ 4/2024 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 28 14.98 467 196 0.20 / 481.43 2 2
2 7 2003.92 32 14.79 2952 1397 1.59 / 482.82 2 2
3 13 1581.76 31 14.75 2408 1101 2.69 / 483.92 2 3
4 13 611.92 31 14.91 1129 522 3.22 / 484.45 2 4
5 8 0.20 180 15.04 272 736 3.95 / 485.18 2 3
Average= 3.88
(KJ/cycle)

Cycle 123 GMT 11/ 4/2024 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 28 14.98 438 184 0.18 / 477.57 2 2
2 7 2003.16 33 14.78 2928 1428 1.61 / 478.99 2 3
3 13 1449.92 31 14.78 2226 1020 2.63 / 480.01 2 3
4 13 521.68 31 14.93 1011 468 3.10 / 480.48 2 3
5 8 -0.08 180 15.04 276 747 3.85 / 481.23 2 2
Average= 3.88
(KJ/cycle)

Cycle 122 GMT 1/ 4/2024 17:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 14.98 458 192 0.19 / 473.65 2 2
2 7 2003.24 32 14.78 2953 1397 1.59 / 475.05 2 2
3 13 1575.84 31 14.76 2396 1096 2.69 / 476.14 2 4
4 13 582.60 31 14.93 1090 504 3.19 / 476.65 2 3
5 8 0.00 180 15.05 272 737 3.93 / 477.38 2 3
Average= 3.88
(KJ/cycle)

Cycle 121 GMT 22/ 3/2024 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 28 14.99 456 191 0.19 / 469.63 2 2
2 7 2008.44 32 14.78 2951 1396 1.59 / 471.03 2 2
3 13 1605.08 31 14.75 2428 1110 2.70 / 472.14 2 3
4 13 604.52 31 14.92 1120 518 3.22 / 472.66 2 4
5 8 -0.08 180 15.05 273 740 3.95 / 473.40 2 2
6 14 -0.08 15 15.03 273 62 4.02 / 473.46 2 2
Average= 3.88
(KJ/cycle)

Cycle 120 GMT 12/ 3/2024 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 28 14.99 462 194 0.19 / 465.81 2 2
2 7 2009.12 32 14.79 2943 1393 1.59 / 467.21 2 2
3 13 1464.76 31 14.79 2247 1030 2.62 / 468.24 2 3
4 13 530.52 31 14.95 1019 472 3.09 / 468.71 2 3
5 8 0.16 180 15.06 270 732 3.82 / 469.44 2 2
Average= 3.88
(KJ/cycle)

Cycle 119 GMT 3/ 3/2024 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 28 14.99 461 193 0.19 / 461.87 2 2
2 7 2008.04 32 14.79 2959 1400 1.59 / 463.27 2 2
3 13 1579.36 31 14.77 2404 1101 2.69 / 464.37 2 3
4 13 596.36 31 14.93 1109 513 3.21 / 464.88 2 3
5 8 0.24 180 15.05 272 737 3.94 / 465.62 2 2
Average= 3.88
(KJ/cycle)

Cycle 118 GMT 22/ 2/2024 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 28 15.00 452 190 0.19 / 457.97 2 2
2 7 2005.12 32 14.79 2953 1398 1.59 / 459.36 2 2
3 13 1465.32 31 14.79 2252 1033 2.62 / 460.40 2 3
4 13 649.96 31 14.92 1180 546 3.17 / 460.94 2 3
5 8 0.00 180 15.05 270 731 3.90 / 461.67 2 3
Average= 3.88
(KJ/cycle)

Cycle 117 GMT 12/ 2/2024 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 28 14.99 471 198 0.20 / 454.05 2 2
2 7 2002.12 32 14.81 2933 1390 1.59 / 455.44 2 3
3 13 1570.20 31 14.78 2386 1093 2.68 / 456.53 2 3
4 13 595.32 31 14.94 1105 512 3.19 / 457.05 2 3
5 8 0.00 180 15.06 270 732 3.92 / 457.78 2 2
Average= 3.88
(KJ/cycle)

Cycle 116 GMT 2/ 2/2024 8: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 28 15.00 438 184 0.18 / 450.03 2 2
2 7 2010.44 32 14.79 2962 1402 1.59 / 451.43 2 2
3 13 1589.52 31 14.77 2402 1100 2.69 / 452.53 2 4
4 13 611.24 31 14.93 1129 523 3.21 / 453.06 2 3
5 8 -0.08 180 15.06 271 735 3.94 / 453.79 2 3
6 14 -0.08 15 15.04 272 61 4.00 / 453.85 2 3
Average= 3.88
(KJ/cycle)

Cycle 115 GMT 23/ 1/2024 10:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 28 14.99 464 195 0.19 / 446.09 2 2
2 10 1013.56 2 14.94 1743 52 0.25 / 446.14 2 2
3 3 959.88 -1 15.36 0 0 0.05 / 446.14 2 2
4 7 2008.80 33 14.79 2952 1441 1.69 / 447.58 2 2
5 13 1445.24 31 14.79 2217 1016 2.70 / 448.59 2 3
6 13 520.00 31 14.94 1009 467 3.17 / 449.06 2 3
7 8 0.72 180 15.05 268 726 3.90 / 449.79 2 3
8 14 0.72 15 15.04 268 60 3.96 / 449.85 2 2
Average= 3.88
(KJ/cycle)

Cycle 114 GMT 13/ 1/2024 12:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 28 15.00 464 195 0.19 / 442.09 2 2
2 3 1016.40 1 15.12 1740 26 0.22 / 442.12 2 2
3 7 2005.96 32 14.81 2948 1397 1.62 / 443.51 2 2
4 13 1582.08 31 14.78 2391 1096 2.71 / 444.61 2 3
5 13 655.36 31 14.95 1186 550 3.26 / 445.16 2 4
6 8 -0.36 180 15.07 270 732 4.00 / 445.89 2 2
Average= 3.88
(KJ/cycle)

Cycle 113 GMT 3/ 1/2024 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 28 14.99 472 198 0.20 / 438.25 2 2
2 7 2006.00 32 14.79 2956 1399 1.60 / 439.65 2 2
3 13 1463.00 31 14.80 2243 1029 2.63 / 440.68 2 3
4 13 533.88 31 14.95 1027 476 3.10 / 441.15 2 3
5 8 0.44 180 15.06 273 740 3.84 / 441.89 2 3
Average= 3.88
(KJ/cycle)

Cycle 112 GMT 24/12/2023 17:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 14.99 465 195 0.20 / 434.43 2 2
2 7 2004.12 32 14.80 2950 1397 1.59 / 435.82 2 2
3 13 1453.00 31 14.80 2230 1023 2.62 / 436.85 2 3
4 13 506.24 31 14.96 994 461 3.08 / 437.31 2 3
5 8 -0.44 180 15.06 275 745 3.82 / 438.05 2 2
Average= 3.88
(KJ/cycle)

Cycle 111 GMT 14/12/2023 19:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 29 14.98 460 200 0.20 / 430.47 2 2
2 3 965.76 -1 15.36 0 0 0.00 / 430.47 2 2
3 7 2010.52 32 14.79 2950 1396 1.60 / 431.86 2 2
4 13 1594.60 31 14.78 2414 1106 2.70 / 432.97 2 3
5 13 612.84 31 14.93 1133 524 3.23 / 433.49 2 4
6 8 0.04 180 15.06 272 737 3.96 / 434.23 2 2
Average= 3.88
(KJ/cycle)

Cycle 110 GMT 4/12/2023 22: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 29 15.00 462 201 0.20 / 426.51 2 2
2 7 2005.52 32 14.79 2952 1397 1.60 / 427.90 2 3
3 13 1585.28 31 14.76 2407 1101 2.70 / 429.00 2 4
4 13 601.80 31 14.92 1118 517 3.22 / 429.52 2 3
5 8 0.24 180 15.05 275 745 3.96 / 430.27 2 2
Average= 3.88
(KJ/cycle)

Cycle 109 GMT 25/11/2023 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 29 15.01 461 201 0.20 / 422.52 2 2
2 7 2005.60 32 14.80 2958 1401 1.60 / 423.92 2 2
3 13 1470.40 31 14.80 2258 1036 2.64 / 424.96 2 4
4 13 661.84 31 14.91 1189 550 3.19 / 425.51 2 4
5 8 0.20 180 15.06 272 737 3.92 / 426.24 2 3
6 14 0.20 15 15.05 273 62 3.99 / 426.31 2 5
Average= 3.88
(KJ/cycle)

Cycle 108 GMT 15/11/2023 2:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 29 14.98 456 198 0.20 / 418.69 2 2
2 7 2005.08 32 14.81 2934 1390 1.59 / 420.08 2 2
3 13 1463.64 31 14.80 2248 1031 2.62 / 421.11 2 3
4 13 542.76 31 14.95 1038 481 3.10 / 421.59 2 3
5 8 0.04 180 15.06 268 726 3.83 / 422.32 2 3
Average= 3.87
(KJ/cycle)

Cycle 107 GMT 5/11/2023 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 29 15.00 456 198 0.20 / 414.67 2 2
2 7 2009.36 32 14.80 2953 1399 1.60 / 416.07 2 2
3 13 1586.72 31 14.77 2402 1100 2.70 / 417.17 2 6
4 13 616.08 31 14.93 1137 526 3.22 / 417.70 2 3
5 8 0.08 180 15.06 270 732 3.95 / 418.43 2 2
6 14 0.08 15 15.05 271 61 4.02 / 418.49 2 2
Average= 3.87
(KJ/cycle)

Cycle 106 GMT 26/10/2023 7:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 29 15.00 458 199 0.20 / 410.65 2 2
2 7 2011.40 32 14.80 2951 1398 1.60 / 412.05 2 2
3 13 1599.72 31 14.77 2416 1106 2.70 / 413.15 2 3
4 13 627.84 31 14.92 1147 531 3.23 / 413.68 2 3
5 8 -0.08 180 15.06 270 732 3.97 / 414.41 2 3
6 14 -0.08 15 15.05 271 61 4.03 / 414.48 2 2
Average= 3.87
(KJ/cycle)

Cycle 105 GMT 16/10/2023 9:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 29 15.01 444 193 0.19 / 406.62 2 2
2 7 2004.12 32 14.81 2947 1397 1.59 / 408.02 2 2
3 13 1594.24 31 14.78 2407 1103 2.69 / 409.12 2 4
4 13 628.72 31 14.93 1152 533 3.23 / 409.66 2 3
5 8 0.12 180 15.06 270 732 3.96 / 410.39 2 2
6 14 0.12 15 15.04 270 61 4.02 / 410.45 2 2
Average= 3.87
(KJ/cycle)

Cycle 104 GMT 6/10/2023 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 27 15.01 473 192 0.19 / 402.57 2 2
2 10 1032.52 2 14.98 1768 53 0.24 / 402.63 2 2
3 7 2006.00 32 14.81 2950 1398 1.64 / 404.03 2 2
4 13 1584.80 31 14.79 2396 1099 2.74 / 405.12 2 4
5 13 605.52 31 14.94 1120 519 3.26 / 405.64 2 3
6 8 0.08 180 15.07 268 727 3.99 / 406.37 2 2
7 14 0.08 15 15.05 269 61 4.05 / 406.43 2 2
Average= 3.87
(KJ/cycle)

Cycle 103 GMT 26/ 9/2023 14: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 27 14.99 465 188 0.19 / 398.46 2 2
2 10 1002.76 2 14.96 1735 52 0.24 / 398.51 2 2
3 3 959.64 -1 15.35 0 0 0.05 / 398.51 2 2
4 7 2002.88 32 14.82 2947 1398 1.64 / 399.91 2 2
5 13 1572.20 31 14.79 2376 1089 2.73 / 401.00 2 4
6 13 613.04 31 14.95 1129 523 3.25 / 401.52 2 3
7 13 53.92 5 15.10 353 27 3.28 / 401.55 2 2
8 13 47.32 5 15.09 348 26 3.30 / 401.57 2 2
9 8 0.08 180 15.06 276 748 4.05 / 402.32 2 3
10 14 0.08 15 15.05 278 63 4.11 / 402.38 2 3
Average= 3.87
(KJ/cycle)

Cycle 102 GMT 16/ 9/2023 16:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 27 15.00 473 192 0.19 / 394.57 2 2
2 7 2007.76 32 14.79 2954 1398 1.59 / 395.96 2 2
3 13 1452.64 31 14.79 2229 1022 2.61 / 396.99 2 3
4 13 531.16 31 14.96 1026 476 3.09 / 397.46 2 3
5 8 0.16 180 15.06 275 745 3.83 / 398.21 2 2
6 14 0.16 15 15.05 274 62 3.89 / 398.27 2 2
Average= 3.87
(KJ/cycle)

Cycle 101 GMT 6/ 9/2023 19: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 27 15.00 465 188 0.19 / 390.70 2 2
2 7 2006.92 32 14.81 2953 1399 1.59 / 392.10 2 2
3 13 1468.04 31 14.81 2260 1038 2.63 / 393.14 2 3
4 13 525.20 31 14.96 1020 473 3.10 / 393.61 2 3
5 8 -0.04 180 15.06 280 759 3.86 / 394.37 2 2
Average= 3.87
(KJ/cycle)

Cycle 100 GMT 27/ 8/2023 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 27 15.00 472 191 0.19 / 386.72 2 2
2 7 2010.64 32 14.81 2962 1404 1.59 / 388.12 2 2
3 13 1599.32 31 14.77 2418 1107 2.70 / 389.23 2 5
4 13 624.00 31 14.94 1150 533 3.23 / 389.76 2 3
5 8 -0.12 180 15.07 278 754 3.99 / 390.52 2 2
Average= 3.87
(KJ/cycle)

Cycle 99 GMT 18/ 8/2023 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 27 15.00 463 188 0.19 / 382.76 2 2
2 7 2004.64 32 14.81 2941 1394 1.58 / 384.16 2 2
3 13 1586.92 31 14.78 2411 1105 2.69 / 385.26 2 5
4 13 600.44 31 14.94 1121 519 3.21 / 385.78 2 3
5 8 0.20 180 15.07 276 749 3.95 / 386.53 2 2
Average= 3.87
(KJ/cycle)

Cycle 98 GMT 8/ 8/2023 2:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 27 14.99 469 190 0.19 / 378.82 2 2
2 7 2009.04 32 14.80 2953 1399 1.59 / 380.22 2 2
3 13 1584.40 31 14.78 2403 1101 2.69 / 381.32 2 3
4 13 586.00 31 14.95 1097 508 3.20 / 381.83 2 3
5 8 0.00 180 15.07 275 746 3.94 / 382.57 2 2
Average= 3.86
(KJ/cycle)

Cycle 97 GMT 29/ 7/2023 4:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 27 15.00 463 188 0.19 / 374.98 2 2
2 7 2004.96 32 14.80 2962 1403 1.59 / 376.38 2 2
3 13 1466.68 31 14.80 2254 1034 2.62 / 377.41 2 5
4 13 503.60 31 14.96 988 458 3.08 / 377.87 2 3
5 8 0.24 180 15.06 280 759 3.84 / 378.63 2 2
Average= 3.86
(KJ/cycle)

Cycle 96 GMT 19/ 7/2023 7: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 27 15.02 461 187 0.19 / 371.01 2 2
2 7 2003.00 32 14.80 2958 1401 1.59 / 372.42 2 2
3 13 1455.28 31 14.81 2236 1027 2.61 / 373.44 2 3
4 13 630.32 31 14.93 1156 535 3.15 / 373.98 2 3
5 8 0.16 180 15.07 276 749 3.90 / 374.73 2 2
6 14 0.16 15 15.05 278 63 3.96 / 374.79 2 2
Average= 3.86
(KJ/cycle)

Cycle 95 GMT 9/ 7/2023 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 27 15.00 466 189 0.19 / 367.19 2 2
2 7 2004.12 32 14.81 2938 1392 1.58 / 368.58 2 2
3 13 1456.36 31 14.81 2238 1027 2.61 / 369.61 2 3
4 13 506.08 31 14.97 996 462 3.07 / 370.07 2 3
5 8 0.04 180 15.08 278 755 3.83 / 370.83 2 2
Average= 3.86
(KJ/cycle)

Cycle 94 GMT 29/ 6/2023 11:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 27 15.02 459 186 0.19 / 363.29 2 2
2 3 1017.88 1 15.08 1748 26 0.21 / 363.32 2 2
3 7 2002.76 32 14.80 2937 1391 1.60 / 364.71 2 2
4 13 1444.04 31 14.81 2214 1016 2.62 / 365.73 2 3
5 13 604.60 31 14.95 1122 520 3.14 / 366.25 2 3
6 8 0.24 180 15.07 278 754 3.89 / 367.00 2 2
Average= 3.86
(KJ/cycle)

Cycle 93 GMT 19/ 6/2023 14: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 27 15.00 467 189 0.19 / 359.40 2 2
2 7 2010.64 32 14.81 2962 1404 1.59 / 360.81 2 3
3 13 1589.84 31 14.78 2413 1106 2.70 / 361.91 2 3
4 13 470.92 31 14.98 946 439 3.14 / 362.35 2 3
5 8 0.24 180 15.08 278 755 3.89 / 363.11 2 2
Average= 3.86
(KJ/cycle)

Cycle 92 GMT 9/ 6/2023 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 27 15.01 480 195 0.19 / 355.51 2 2
2 7 2006.08 32 14.80 2960 1402 1.60 / 356.91 2 2
3 13 1450.76 31 14.80 2235 1025 2.62 / 357.93 2 4
4 13 613.08 31 14.96 1140 529 3.15 / 358.46 2 3
5 8 0.08 180 15.08 278 755 3.91 / 359.22 2 2
Average= 3.86
(KJ/cycle)

Cycle 91 GMT 30/ 5/2023 19: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 27 15.01 470 190 0.19 / 351.50 2 2
2 7 2011.32 33 14.79 2959 1444 1.63 / 352.95 2 2
3 13 1590.32 31 14.77 2416 1106 2.74 / 354.05 2 3
4 13 465.44 31 14.99 947 440 3.18 / 354.49 2 3
5 8 -0.16 180 15.08 278 755 3.94 / 355.25 2 2
6 14 -0.16 15 15.06 278 63 4.00 / 355.31 2 2
Average= 3.86
(KJ/cycle)

Cycle 90 GMT 20/ 5/2023 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 27 15.00 481 195 0.19 / 347.53 2 2
2 7 2004.12 32 14.81 2950 1398 1.59 / 348.93 2 2
3 13 1594.00 31 14.78 2414 1106 2.70 / 350.04 2 3
4 13 595.40 31 14.96 1112 516 3.21 / 350.55 2 4
5 8 0.36 180 15.08 279 757 3.97 / 351.31 2 2
Average= 3.86
(KJ/cycle)

Cycle 89 GMT 10/ 5/2023 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 27 15.01 477 193 0.19 / 343.58 2 2
2 7 2007.00 32 14.80 2956 1400 1.59 / 344.98 2 2
3 13 1587.36 31 14.77 2407 1102 2.70 / 346.08 2 4
4 13 579.12 31 14.96 1089 505 3.20 / 346.59 2 4
5 8 0.04 180 15.07 278 754 3.95 / 347.34 2 2
Average= 3.86
(KJ/cycle)

Cycle 88 GMT 1/ 5/2023 2: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 27 15.02 476 193 0.19 / 339.72 2 2
2 7 2002.20 32 14.81 2943 1395 1.59 / 341.12 2 3
3 13 1577.40 31 14.79 2398 1099 2.69 / 342.22 2 3
4 13 424.68 31 15.00 885 412 3.10 / 342.63 2 3
5 8 0.20 180 15.09 278 755 3.85 / 343.39 2 2
Average= 3.86
(KJ/cycle)

Cycle 87 GMT 21/ 4/2023 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 27 15.01 463 188 0.19 / 335.71 2 2
2 7 2008.44 32 14.80 2960 1402 1.59 / 337.12 2 2
3 13 1575.04 31 14.78 2400 1100 2.69 / 338.22 2 3
4 13 566.72 31 14.96 1072 497 3.19 / 338.71 2 3
5 8 0.04 180 15.09 278 755 3.94 / 339.47 2 2
6 14 0.04 15 15.07 279 63 4.00 / 339.53 2 2
Average= 3.86
(KJ/cycle)

Cycle 86 GMT 11/ 4/2023 6:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 27 15.02 480 195 0.19 / 331.88 2 2
2 7 2003.32 32 14.81 2943 1395 1.59 / 333.28 2 3
3 13 1453.16 31 14.81 2238 1027 2.62 / 334.31 2 3
4 13 493.60 31 14.99 981 456 3.07 / 334.76 2 3
5 8 -0.32 180 15.08 282 765 3.84 / 335.53 2 3
Average= 3.86
(KJ/cycle)

Cycle 85 GMT 1/ 4/2023 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 27 15.02 438 178 0.18 / 328.05 2 2
2 7 2006.44 32 14.81 2954 1400 1.58 / 329.45 2 3
3 13 1459.32 31 14.82 2246 1032 2.61 / 330.48 2 5
4 13 484.08 31 15.00 969 451 3.06 / 330.93 2 3
5 8 0.12 180 15.08 279 757 3.82 / 331.69 2 2
Average= 3.86
(KJ/cycle)

Cycle 84 GMT 22/ 3/2023 11:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 27 15.02 459 186 0.19 / 324.17 2 2
2 7 2008.08 32 14.82 2961 1404 1.59 / 325.58 2 3
3 13 1579.88 31 14.80 2394 1098 2.69 / 326.68 2 4
4 13 468.72 31 15.01 945 440 3.13 / 327.12 2 3
5 8 0.16 180 15.09 278 755 3.88 / 327.87 2 2
Average= 3.86
(KJ/cycle)

Cycle 83 GMT 12/ 3/2023 13:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 27 15.03 479 194 0.19 / 320.38 2 2
2 7 2003.52 32 14.82 2953 1400 1.59 / 321.78 2 4
3 13 1428.68 31 14.83 2200 1011 2.61 / 322.79 2 4
4 13 475.88 31 15.00 956 445 3.05 / 323.24 2 3
5 8 -0.24 180 15.09 277 752 3.80 / 323.99 2 2
Average= 3.86
(KJ/cycle)

Cycle 82 GMT 2/ 3/2023 16:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 27 15.03 465 189 0.19 / 316.42 2 2
2 7 2009.32 32 14.82 2962 1405 1.59 / 317.82 2 2
3 13 1581.12 31 14.79 2401 1101 2.69 / 318.92 2 4
4 13 572.84 31 14.97 1089 505 3.20 / 319.43 2 3
5 8 0.24 180 15.09 278 755 3.95 / 320.19 2 2
Average= 3.86
(KJ/cycle)

Cycle 81 GMT 20/ 2/2023 18:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 27 15.03 466 189 0.19 / 312.55 2 2
2 7 2004.32 32 14.83 2948 1399 1.59 / 313.95 2 2
3 13 1567.24 31 14.79 2384 1093 2.68 / 315.04 2 3
4 13 466.00 31 15.01 939 437 3.12 / 315.48 2 3
5 8 0.04 180 15.09 278 755 3.87 / 316.23 2 2
Average= 3.86
(KJ/cycle)

Cycle 80 GMT 10/ 2/2023 21: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 27 15.02 467 189 0.19 / 308.66 2 2
2 7 2002.84 32 14.82 2949 1399 1.59 / 310.06 2 3
3 13 1574.24 31 14.80 2385 1094 2.68 / 311.15 2 3
4 13 461.88 31 15.01 935 435 3.12 / 311.59 2 3
5 8 0.12 180 15.10 284 772 3.89 / 312.36 2 2
Average= 3.86
(KJ/cycle)

Cycle 79 GMT 31/ 1/2023 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 27 15.04 463 188 0.19 / 304.82 2 2
2 7 2010.08 32 14.83 2959 1404 1.59 / 306.22 2 3
3 13 1455.88 31 14.82 2243 1030 2.62 / 307.25 2 3
4 13 490.20 31 15.01 972 452 3.07 / 307.71 2 3
5 8 0.28 180 15.10 280 761 3.84 / 308.47 2 2
Average= 3.86
(KJ/cycle)

Cycle 78 GMT 22/ 1/2023 1:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 27 15.03 461 187 0.19 / 300.95 2 2
2 7 2004.36 32 14.83 2944 1397 1.58 / 302.35 2 4
3 13 1570.84 31 14.82 2390 1098 2.68 / 303.45 2 4
4 13 459.32 31 15.02 931 433 3.12 / 303.88 2 4
5 8 -0.16 180 15.11 277 753 3.87 / 304.63 2 2
Average= 3.86
(KJ/cycle)

Cycle 77 GMT 12/ 1/2023 4: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 27 15.04 462 188 0.19 / 297.00 2 2
2 7 2002.56 32 14.83 2938 1394 1.58 / 298.40 2 2
3 13 1578.44 31 14.82 2393 1099 2.68 / 299.50 2 3
4 13 466.48 31 15.03 939 438 3.12 / 299.93 2 3
5 8 -0.12 180 15.11 282 767 3.89 / 300.70 2 2
6 14 -0.12 15 15.10 279 63 3.95 / 300.76 2 2
Average= 3.86
(KJ/cycle)

Cycle 76 GMT 2/ 1/2023 6:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 27 15.04 460 187 0.19 / 292.92 2 2
2 7 2004.48 33 14.84 2937 1438 1.63 / 294.36 2 3
3 13 1448.28 31 14.85 2228 1026 2.65 / 295.39 2 4
4 13 506.36 31 15.02 995 463 3.11 / 295.85 2 3
5 13 15.92 31 15.14 292 137 3.25 / 295.99 2 2
6 8 0.00 180 15.10 280 761 4.01 / 296.75 2 3
7 14 0.00 15 15.08 282 64 4.08 / 296.81 2 2
Average= 3.85
(KJ/cycle)

Cycle 75 GMT 23/12/2022 8:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 27 15.05 465 189 0.19 / 288.94 2 2
2 7 2003.28 32 14.84 2940 1396 1.59 / 290.34 2 4
3 13 1564.32 31 14.82 2377 1092 2.68 / 291.43 2 4
4 13 560.08 31 14.99 1060 493 3.17 / 291.92 2 3
5 8 -0.16 180 15.11 276 751 3.92 / 292.68 2 2
6 14 -0.16 15 15.10 276 63 3.98 / 292.74 2 2
Average= 3.85
(KJ/cycle)

Cycle 74 GMT 13/12/2022 11: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 27 15.04 458 186 0.19 / 285.07 2 2
2 7 2002.16 32 14.84 2935 1394 1.58 / 286.46 2 2
3 13 1443.68 31 14.85 2220 1022 2.60 / 287.48 2 3
4 13 500.60 31 15.03 985 459 3.06 / 287.94 2 4
5 8 0.44 180 15.12 276 751 3.81 / 288.69 2 2
6 14 0.44 15 15.10 278 63 3.87 / 288.76 2 2
Average= 3.85
(KJ/cycle)

Cycle 73 GMT 3/12/2022 13:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 27 15.07 464 189 0.19 / 281.21 2 2
2 7 2006.64 32 14.85 2958 1406 1.59 / 282.62 2 3
3 13 1463.48 31 14.84 2246 1033 2.63 / 283.65 2 3
4 13 528.16 31 15.00 1019 474 3.10 / 284.13 2 3
5 8 -0.12 180 15.11 277 753 3.85 / 284.88 2 2
Average= 3.85
(KJ/cycle)

Cycle 72 GMT 23/11/2022 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 27 15.05 468 190 0.19 / 277.34 2 2
2 7 2004.28 32 14.86 2950 1403 1.59 / 278.74 2 3
3 13 1467.72 31 14.84 2255 1037 2.63 / 279.78 2 3
4 13 527.64 31 15.02 1023 476 3.11 / 280.26 2 4
5 8 0.36 180 15.12 282 767 3.87 / 281.03 2 2
Average= 3.85
(KJ/cycle)

Cycle 71 GMT 13/11/2022 18: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 27 15.06 456 185 0.19 / 273.41 2 2
2 7 2008.68 32 14.85 2953 1403 1.59 / 274.82 2 2
3 13 1589.48 31 14.83 2416 1111 2.70 / 275.93 2 3
4 13 492.08 31 15.03 974 454 3.15 / 276.38 2 3
5 8 0.36 180 15.12 283 770 3.92 / 277.15 2 2
Average= 3.85
(KJ/cycle)

Cycle 70 GMT 3/11/2022 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 27 15.05 464 189 0.19 / 269.58 2 2
2 7 2011.36 32 14.84 2962 1407 1.60 / 270.99 2 3
3 13 1450.84 31 14.84 2220 1021 2.62 / 272.01 2 5
4 13 499.08 31 15.03 985 459 3.08 / 272.47 2 3
5 8 0.12 180 15.13 278 757 3.83 / 273.23 2 2
Average= 3.85
(KJ/cycle)

Cycle 69 GMT 24/10/2022 22:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 28 15.08 472 199 0.20 / 265.69 2 2
2 7 2009.00 33 14.83 2958 1448 1.65 / 267.13 2 2
3 13 1452.04 31 14.83 2232 1026 2.67 / 268.16 2 5
4 13 513.68 31 15.02 1001 466 3.14 / 268.63 2 3
5 8 -0.08 180 15.12 283 770 3.91 / 269.40 2 2
Average= 3.85
(KJ/cycle)

Cycle 68 GMT 15/10/2022 0:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 15.07 452 191 0.19 / 261.77 2 2
2 7 2003.60 32 14.85 2956 1405 1.60 / 263.17 2 3
3 13 1453.36 31 14.85 2229 1026 2.62 / 264.20 2 4
4 13 615.92 31 15.00 1138 529 3.15 / 264.73 2 3
5 8 0.32 180 15.14 279 760 3.91 / 265.49 2 2
Average= 3.85
(KJ/cycle)

Cycle 67 GMT 5/10/2022 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 15.06 457 193 0.19 / 257.86 2 2
2 7 2003.12 32 14.84 2935 1394 1.59 / 259.25 2 5
3 13 1464.24 31 14.86 2248 1036 2.62 / 260.29 2 3
4 13 514.92 31 15.04 1005 469 3.09 / 260.75 2 3
5 8 0.16 180 15.13 278 757 3.85 / 261.51 2 2
6 14 0.16 15 15.12 282 64 3.91 / 261.58 2 2
Average= 3.85
(KJ/cycle)

Cycle 66 GMT 25/ 9/2022 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 28 15.09 456 193 0.19 / 253.84 2 2
2 7 2009.48 32 14.85 2950 1402 1.59 / 255.24 2 3
3 13 1571.12 31 14.83 2388 1098 2.69 / 256.34 2 3
4 13 576.72 31 15.01 1083 504 3.20 / 256.84 2 3
5 8 0.20 180 15.13 278 757 3.95 / 257.60 2 2
6 14 0.20 15 15.12 281 64 4.02 / 257.66 2 3
Average= 3.85
(KJ/cycle)

Cycle 65 GMT 15/ 9/2022 7:17:53

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 28 15.08 468 198 0.20 / 249.89 2 2
2 7 2003.64 33 14.86 2941 1442 1.64 / 251.33 2 2
3 13 1444.48 31 14.86 2217 1021 2.66 / 252.36 2 4
4 13 508.60 31 15.04 994 463 3.12 / 252.82 2 3
5 8 0.20 180 15.15 280 764 3.89 / 253.58 2 2
6 14 0.20 15 15.13 282 64 3.95 / 253.65 2 2
Average= 3.84
(KJ/cycle)

Cycle 64 GMT 5/ 9/2022 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 27 15.08 450 183 0.18 / 245.89 2 2
2 3 1018.64 1 15.15 1759 27 0.21 / 245.92 2 2
3 7 2002.44 32 14.86 2936 1396 1.61 / 247.32 2 3
4 13 1578.88 31 14.84 2389 1099 2.71 / 248.41 2 3
5 13 597.12 31 15.02 1110 517 3.22 / 248.93 2 3
6 8 -0.04 180 15.14 280 763 3.98 / 249.69 2 2
Average= 3.84
(KJ/cycle)

Cycle 63 GMT 26/ 8/2022 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 27 15.09 464 189 0.19 / 241.95 2 2
2 7 2004.80 33 14.84 2941 1440 1.63 / 243.39 2 3
3 13 1461.20 31 14.85 2251 1036 2.67 / 244.43 2 3
4 13 494.24 31 15.04 976 455 3.12 / 244.88 2 3
5 8 1.88 180 15.14 280 763 3.88 / 245.65 2 2
6 14 1.88 15 15.13 282 64 3.95 / 245.71 2 2
Average= 3.84
(KJ/cycle)

Cycle 62 GMT 16/ 8/2022 13:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 27 15.08 460 187 0.19 / 238.07 2 2
2 7 2002.20 33 14.86 2953 1448 1.64 / 239.52 2 2
3 13 1449.00 31 14.86 2226 1025 2.66 / 240.55 2 3
4 13 481.84 31 15.06 961 449 3.11 / 240.99 2 3
5 8 0.36 180 15.16 281 767 3.88 / 241.76 2 3
Average= 3.84
(KJ/cycle)

Cycle 61 GMT 6/ 8/2022 16:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 27 15.08 461 188 0.19 / 234.05 2 2
2 10 1002.08 2 15.02 1730 52 0.24 / 234.11 2 2
3 3 941.60 -2 15.42 0 0 0.05 / 234.11 2 2
4 7 2005.04 33 14.85 2955 1448 1.69 / 235.55 2 3
5 13 1453.72 31 14.86 2231 1028 2.72 / 236.58 2 3
6 13 508.80 31 15.05 995 464 3.18 / 237.05 2 3
7 8 -0.04 180 15.15 284 774 3.95 / 237.82 2 2
8 14 -0.04 15 15.14 284 64 4.02 / 237.89 2 2
Average= 3.84
(KJ/cycle)

Cycle 60 GMT 27/ 7/2022 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 27 15.09 454 185 0.18 / 230.06 2 2
2 7 2003.76 32 14.86 2945 1400 1.59 / 231.46 2 2
3 13 1449.12 31 14.85 2228 1026 2.61 / 232.48 2 4
4 13 622.12 31 15.02 1147 534 3.15 / 233.02 2 3
5 8 0.04 180 15.15 287 783 3.93 / 233.80 2 2
6 14 0.04 15 15.14 287 65 3.99 / 233.87 2 2
Average= 3.83
(KJ/cycle)

Cycle 59 GMT 17/ 7/2022 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 27 15.09 460 187 0.19 / 226.16 2 2
2 7 2008.56 32 14.85 2953 1403 1.59 / 227.56 2 2
3 13 1458.12 31 14.86 2234 1029 2.62 / 228.59 2 3
4 13 497.00 31 15.06 975 455 3.07 / 229.05 2 3
5 8 0.40 180 15.16 280 764 3.84 / 229.81 2 2
6 14 0.40 15 15.14 283 64 3.90 / 229.87 2 2
Average= 3.83
(KJ/cycle)

Cycle 58 GMT 7/ 7/2022 22:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 27 15.09 474 193 0.19 / 222.04 2 2
2 7 2003.32 32 14.85 2948 1401 1.59 / 223.44 2 3
3 13 1577.64 31 14.84 2393 1101 2.69 / 224.54 2 5
4 13 584.68 31 15.04 1098 512 3.21 / 225.05 2 3
5 13 16.04 31 15.19 295 139 3.35 / 225.19 2 2
6 8 -0.08 180 15.14 286 779 4.13 / 225.97 2 2
Average= 3.83
(KJ/cycle)

Cycle 57 GMT 28/ 6/2022 0:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 27 15.09 478 195 0.19 / 218.02 2 2
2 7 2003.88 33 14.86 2941 1442 1.64 / 219.46 2 3
3 13 1443.44 31 14.87 2221 1024 2.66 / 220.49 2 3
4 13 616.76 31 15.03 1136 529 3.19 / 221.01 2 3
5 8 0.04 180 15.16 281 767 3.96 / 221.78 2 2
6 14 0.04 15 15.15 282 64 4.02 / 221.85 2 2
Average= 3.82
(KJ/cycle)

Cycle 56 GMT 18/ 6/2022 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 27 15.10 470 192 0.19 / 214.14 2 2
2 7 2005.88 33 14.85 2942 1442 1.63 / 215.59 2 3
3 13 1447.80 31 14.87 2228 1027 2.66 / 216.61 2 4
4 13 478.96 31 15.08 956 447 3.11 / 217.06 2 3
5 8 0.04 180 15.17 280 765 3.87 / 217.82 2 2
Average= 3.82
(KJ/cycle)

Cycle 55 GMT 8/ 6/2022 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 27 15.10 456 186 0.19 / 210.18 2 2
2 7 2002.52 32 14.87 2955 1406 1.59 / 211.59 2 4
3 13 1571.20 31 14.85 2383 1097 2.69 / 212.68 2 3
4 13 569.28 31 15.05 1074 501 3.19 / 213.19 2 4
5 8 0.36 180 15.17 281 767 3.96 / 213.95 2 2
Average= 3.82
(KJ/cycle)

Cycle 54 GMT 29/ 5/2022 7:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 27 15.10 475 194 0.19 / 206.26 2 2
2 7 2012.40 32 14.87 2956 1407 1.60 / 207.67 2 3
3 13 1474.48 31 14.87 2256 1040 2.64 / 208.71 2 4
4 13 507.28 31 15.06 995 465 3.10 / 209.17 2 3
5 8 0.08 180 15.17 279 762 3.87 / 209.93 2 2
6 14 0.08 15 15.16 279 63 3.93 / 210.00 2 2
Average= 3.82
(KJ/cycle)

Cycle 53 GMT 19/ 5/2022 9:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 27 15.11 481 196 0.20 / 202.42 2 2
2 7 2004.00 32 14.87 2945 1401 1.60 / 203.82 2 2
3 13 1456.84 31 14.87 2231 1028 2.63 / 204.85 2 3
4 13 491.52 31 15.08 971 454 3.08 / 205.30 2 3
5 8 0.20 180 15.17 279 762 3.84 / 206.07 2 2
Average= 3.82
(KJ/cycle)

Cycle 52 GMT 9/ 5/2022 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 27 15.12 464 189 0.19 / 198.50 2 2
2 7 2009.00 32 14.86 2944 1400 1.59 / 199.90 2 2
3 13 1457.80 31 14.86 2232 1028 2.62 / 200.93 2 5
4 13 501.72 31 15.08 990 463 3.08 / 201.39 2 3
5 8 -0.20 180 15.17 280 765 3.84 / 202.16 2 3
6 14 -0.20 15 15.16 281 64 3.91 / 202.22 2 2
Average= 3.82
(KJ/cycle)

Cycle 51 GMT 29/ 4/2022 14:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 27 15.13 462 189 0.19 / 194.46 2 2
2 7 2009.04 32 14.88 2956 1408 1.60 / 195.87 2 3
3 13 1573.40 31 14.86 2380 1096 2.69 / 196.97 2 4
4 13 601.88 31 15.05 1115 520 3.21 / 197.49 2 4
5 8 0.04 180 15.17 279 762 3.97 / 198.25 2 2
6 14 0.04 15 15.16 281 64 4.04 / 198.31 2 2
Average= 3.81
(KJ/cycle)

Cycle 50 GMT 19/ 4/2022 16:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 27 15.12 472 193 0.19 / 190.50 2 2
2 7 2003.84 32 14.88 2953 1406 1.60 / 191.90 2 2
3 13 1576.56 31 14.86 2388 1100 2.70 / 193.00 2 3
4 13 576.04 31 15.08 1087 508 3.21 / 193.51 2 4
5 8 0.44 180 15.19 280 766 3.97 / 194.28 2 2
Average= 3.81
(KJ/cycle)

Cycle 49 GMT 9/ 4/2022 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 27 15.14 466 190 0.19 / 186.67 2 2
2 7 2008.56 32 14.87 2942 1400 1.59 / 188.07 2 2
3 13 1447.92 31 14.88 2217 1023 2.61 / 189.09 2 3
4 13 479.92 31 15.09 960 449 3.06 / 189.54 2 3
5 8 -0.32 180 15.19 280 766 3.83 / 190.30 2 2
Average= 3.81
(KJ/cycle)

Cycle 48 GMT 30/ 3/2022 21:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 27 15.13 466 190 0.19 / 182.62 2 2
2 3 1018.08 1 15.19 1771 27 0.22 / 182.65 2 2
3 7 2008.32 32 14.89 2955 1408 1.63 / 184.05 2 3
4 13 1597.36 31 14.87 2423 1117 2.74 / 185.17 2 4
5 13 607.56 31 15.06 1129 527 3.27 / 185.70 2 3
6 8 0.20 180 15.20 284 777 4.05 / 186.48 2 2
Average= 3.81
(KJ/cycle)

Cycle 47 GMT 20/ 3/2022 23:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 27 15.13 473 193 0.19 / 178.58 2 2
2 7 2005.12 32 14.90 2942 1403 1.60 / 179.98 2 3
3 13 1576.84 31 14.87 2390 1102 2.70 / 181.08 2 3
4 13 592.48 31 15.07 1112 519 3.22 / 181.60 2 4
5 8 0.00 180 15.19 279 763 3.98 / 182.37 2 2
6 14 0.00 15 15.19 279 64 4.04 / 182.43 2 2
Average= 3.80
(KJ/cycle)

Cycle 46 GMT 11/ 3/2022 2: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 27 15.13 472 193 0.19 / 174.60 2 2
2 7 2003.24 32 14.89 2954 1408 1.60 / 176.01 2 3
3 13 1573.00 31 14.86 2386 1099 2.70 / 177.11 2 3
4 13 582.72 31 15.07 1095 512 3.21 / 177.62 2 3
5 8 0.12 180 15.20 280 766 3.98 / 178.39 2 2
Average= 3.80
(KJ/cycle)

Cycle 45 GMT 1/ 3/2022 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 27 15.13 469 192 0.19 / 170.75 2 2
2 7 2002.92 32 14.89 2949 1405 1.60 / 172.16 2 3
3 13 1447.60 31 14.89 2236 1032 2.63 / 173.19 2 3
4 13 479.20 31 15.10 960 449 3.08 / 173.64 2 3
5 8 0.00 180 15.19 282 771 3.85 / 174.41 2 2
Average= 3.79
(KJ/cycle)

Cycle 44 GMT 19/ 2/2022 6:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 27 15.14 475 194 0.19 / 166.68 2 2
2 7 2005.96 32 14.89 2965 1413 1.61 / 168.10 2 3
3 13 1580.28 31 14.87 2402 1107 2.71 / 169.20 2 3
4 13 592.20 31 15.07 1110 519 3.23 / 169.72 2 4
5 8 0.00 180 15.20 282 772 4.00 / 170.49 2 2
6 14 0.00 15 15.18 284 65 4.07 / 170.56 2 2
Average= 3.79
(KJ/cycle)

Cycle 43 GMT 9/ 2/2022 9:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 27 15.13 471 192 0.19 / 162.82 2 2
2 7 2002.44 32 14.88 2952 1406 1.60 / 164.22 2 3
3 13 1450.72 31 14.89 2237 1033 2.63 / 165.26 2 3
4 13 495.52 31 15.09 979 458 3.09 / 165.71 2 3
5 8 0.16 180 15.20 284 777 3.87 / 166.49 2 2
Average= 3.78
(KJ/cycle)

Cycle 42 GMT 30/ 1/2022 11:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 27 15.13 482 197 0.20 / 158.74 2 2
2 7 2008.56 32 14.89 2951 1406 1.60 / 160.15 2 3
3 13 1591.48 31 14.86 2409 1110 2.71 / 161.26 2 3
4 13 580.64 31 15.08 1097 513 3.23 / 161.77 2 3
5 8 0.12 180 15.20 288 788 4.01 / 162.56 2 2
6 14 0.12 15 15.19 290 66 4.08 / 162.62 2 2
Average= 3.78
(KJ/cycle)

Cycle 41 GMT 20/ 1/2022 13:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 27 15.14 474 194 0.19 / 154.74 2 2
2 7 2002.84 32 14.89 2949 1405 1.60 / 156.14 2 3
3 13 1589.24 31 14.86 2415 1112 2.71 / 157.26 2 3
4 13 583.52 31 15.07 1098 513 3.22 / 157.77 2 3
5 8 -0.08 180 15.20 284 777 4.00 / 158.55 2 2
Average= 3.77
(KJ/cycle)

Cycle 40 GMT 10/ 1/2022 16:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 27 15.14 475 194 0.19 / 150.87 2 2
2 7 2007.96 32 14.89 2957 1409 1.60 / 152.28 2 2
3 13 1443.56 31 14.91 2226 1029 2.63 / 153.31 2 4
4 13 493.48 31 15.11 979 459 3.09 / 153.77 2 3
5 8 0.36 180 15.21 284 778 3.87 / 154.54 2 2
Average= 3.77
(KJ/cycle)

Cycle 39 GMT 31/12/2021 18:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 27 15.14 485 198 0.20 / 146.99 2 2
2 7 2008.28 32 14.89 2962 1411 1.61 / 148.41 2 3
3 13 1445.24 31 14.92 2229 1031 2.64 / 149.44 2 3
4 13 490.84 31 15.11 979 459 3.10 / 149.90 2 4
5 8 0.36 180 15.21 285 780 3.88 / 150.68 2 3
Average= 3.77
(KJ/cycle)

Cycle 38 GMT 21/12/2021 20:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 27 15.14 473 193 0.19 / 143.11 2 2
2 7 2007.24 32 14.88 2951 1405 1.60 / 144.52 2 2
3 13 1443.44 31 14.91 2223 1027 2.63 / 145.54 2 3
4 13 489.68 31 15.11 975 457 3.08 / 146.00 2 3
5 8 -0.24 180 15.20 291 796 3.88 / 146.80 2 2
Average= 3.76
(KJ/cycle)

Cycle 37 GMT 11/12/2021 23: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 27 15.15 473 193 0.19 / 139.25 2 2
2 7 2008.08 32 14.88 2956 1408 1.60 / 140.66 2 3
3 13 1450.56 31 14.90 2234 1032 2.63 / 141.69 2 4
4 13 470.88 31 15.11 949 445 3.08 / 142.13 2 3
5 8 0.04 180 15.20 286 782 3.86 / 142.92 2 2
Average= 3.76
(KJ/cycle)

Cycle 36 GMT 2/12/2021 1:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 27 15.13 485 198 0.20 / 135.37 2 2
2 7 2009.08 32 14.89 2959 1410 1.61 / 136.78 2 3
3 13 1441.92 31 14.91 2225 1028 2.64 / 137.81 2 4
4 13 477.04 31 15.12 957 449 3.09 / 138.26 2 4
5 8 0.04 180 15.21 292 799 3.88 / 139.06 2 2
Average= 3.76
(KJ/cycle)

Cycle 35 GMT 22/11/2021 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 27 15.17 477 195 0.20 / 131.42 2 2
2 7 2002.84 33 14.89 2946 1448 1.64 / 132.87 2 3
3 13 1556.52 31 14.89 2372 1095 2.74 / 133.96 2 3
4 13 430.40 31 15.13 894 419 3.16 / 134.38 2 3
5 8 0.32 180 15.21 289 791 3.95 / 135.17 2 2
Average= 3.75
(KJ/cycle)

Cycle 34 GMT 12/11/2021 5:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 27 15.14 467 191 0.19 / 127.50 2 2
2 7 2009.76 32 14.90 2965 1414 1.60 / 128.91 2 3
3 13 1584.92 31 14.89 2404 1110 2.71 / 130.02 2 3
4 13 430.36 31 15.14 897 421 3.14 / 130.44 2 3
5 8 0.24 180 15.22 285 781 3.92 / 131.22 2 2
Average= 3.75
(KJ/cycle)

Cycle 33 GMT 2/11/2021 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 27 15.16 482 197 0.20 / 123.42 2 2
2 7 2010.92 32 14.90 2950 1407 1.60 / 124.83 2 3
3 13 1592.16 31 14.88 2422 1117 2.72 / 125.94 2 3
4 13 581.20 31 15.09 1098 514 3.23 / 126.46 2 3
5 8 0.40 180 15.21 287 786 4.02 / 127.24 2 2
6 14 0.40 15 15.20 288 66 4.09 / 127.31 2 2
Average= 3.74
(KJ/cycle)

Cycle 32 GMT 23/10/2021 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 27 15.16 483 198 0.20 / 119.56 2 2
2 7 2003.44 32 14.90 2947 1405 1.60 / 120.96 2 2
3 13 1445.32 31 14.92 2224 1029 2.63 / 121.99 2 5
4 13 483.08 31 15.12 965 452 3.08 / 122.44 2 3
5 8 0.40 180 15.22 284 778 3.86 / 123.22 2 2
Average= 3.73
(KJ/cycle)

Cycle 31 GMT 13/10/2021 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 27 15.15 488 200 0.20 / 115.61 2 2
2 7 2003.68 32 14.92 2944 1406 1.61 / 117.02 2 3
3 13 1444.52 31 14.93 2228 1031 2.64 / 118.05 2 4
4 13 496.76 31 15.13 984 462 3.10 / 118.51 2 3
5 8 -0.20 180 15.22 286 784 3.88 / 119.29 2 2
6 14 -0.20 15 15.21 288 66 3.95 / 119.36 2 2
Average= 3.73
(KJ/cycle)

Cycle 30 GMT 3/10/2021 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 27 15.16 462 189 0.19 / 111.51 2 2
2 7 2003.20 32 14.89 2960 1410 1.60 / 112.92 2 3
3 13 1589.24 31 14.89 2418 1116 2.72 / 114.04 2 3
4 13 592.96 31 15.10 1113 521 3.24 / 114.56 2 3
5 8 0.36 180 15.22 287 786 4.02 / 115.35 2 2
6 14 0.36 15 15.20 291 66 4.09 / 115.41 2 2
Average= 3.72
(KJ/cycle)

Cycle 29 GMT 23/ 9/2021 16:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 26 15.16 455 179 0.18 / 107.72 2 2
2 3 1020.60 1 15.21 1748 27 0.21 / 107.75 2 3
3 7 2010.80 32 14.90 2970 1416 1.62 / 109.16 2 3
4 13 1332.40 31 14.95 2083 965 2.59 / 110.13 2 4
5 13 403.32 31 15.16 858 403 2.99 / 110.53 2 3
6 8 -0.04 180 15.22 289 792 3.78 / 111.32 2 2
Average= 3.71
(KJ/cycle)

Cycle 28 GMT 13/ 9/2021 18:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 26 15.18 484 191 0.19 / 103.82 2 2
2 7 2003.56 32 14.91 2950 1408 1.60 / 105.23 2 3
3 13 1434.92 31 14.94 2217 1027 2.63 / 106.25 2 4
4 13 455.36 31 15.15 934 439 3.06 / 106.69 2 4
5 8 0.16 180 15.24 286 785 3.85 / 107.48 2 2
6 14 0.16 15 15.22 286 65 3.91 / 107.54 2 2
Average= 3.71
(KJ/cycle)

Cycle 27 GMT 3/ 9/2021 20:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 26 15.17 484 191 0.19 / 99.85 2 2
2 3 1017.88 1 15.21 1764 27 0.22 / 99.88 2 3
3 7 2007.96 32 14.91 2947 1406 1.62 / 101.28 2 2
4 13 1457.68 31 14.93 2248 1040 2.66 / 102.32 2 4
5 13 471.40 31 15.15 955 449 3.11 / 102.77 2 3
6 8 -0.08 180 15.24 288 790 3.90 / 103.56 2 3
7 14 -0.08 15 15.22 289 66 3.97 / 103.63 2 2
Average= 3.70
(KJ/cycle)

Cycle 26 GMT 24/ 8/2021 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 26 15.18 476 188 0.19 / 96.15 2 2
2 7 2003.12 32 14.92 2953 1410 1.60 / 97.56 2 5
3 13 1435.96 31 14.94 2220 1028 2.63 / 98.59 2 4
4 13 346.88 13 15.20 803 159 2.78 / 98.75 2 3
5 13 109.16 7 15.26 472 50 2.84 / 98.80 2 3
6 8 0.16 180 15.25 289 793 3.63 / 99.59 2 2
7 14 0.16 15 15.23 290 66 3.69 / 99.66 2 3
Average= 3.69
(KJ/cycle)

Cycle 25 GMT 15/ 8/2021 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 26 15.19 468 185 0.18 / 92.26 2 2
2 7 2003.44 33 14.91 2951 1452 1.64 / 93.71 2 3
3 13 1431.44 31 14.95 2206 1022 2.66 / 94.73 2 4
4 13 461.64 31 15.16 940 442 3.10 / 95.17 2 3
5 8 -0.08 180 15.25 289 793 3.89 / 95.96 2 2
Average= 3.69
(KJ/cycle)

Cycle 24 GMT 5/ 8/2021 2:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 26 15.19 470 186 0.19 / 88.27 2 2
2 7 2008.24 33 14.93 2966 1461 1.65 / 89.74 2 3
3 13 1587.92 31 14.92 2418 1118 2.77 / 90.85 2 3
4 13 441.40 31 15.16 912 429 3.19 / 91.28 2 3
5 8 0.12 180 15.25 287 788 3.98 / 92.07 2 2
Average= 3.68
(KJ/cycle)

Cycle 23 GMT 26/ 7/2021 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 26 15.19 473 187 0.19 / 84.42 2 2
2 7 2002.60 32 14.92 2962 1414 1.60 / 85.83 2 2
3 13 1426.84 31 14.96 2214 1027 2.63 / 86.86 2 3
4 13 456.16 31 15.16 938 441 3.07 / 87.30 2 3
5 8 0.08 180 15.25 288 791 3.86 / 88.09 2 2
Average= 3.67
(KJ/cycle)

Cycle 22 GMT 16/ 7/2021 7: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 26 15.18 462 182 0.18 / 80.54 2 2
2 3 1024.96 1 15.24 1782 27 0.21 / 80.57 2 3
3 7 2003.44 32 14.92 2957 1412 1.62 / 81.98 2 2
4 13 1425.36 31 14.96 2204 1022 2.64 / 83.00 2 3
5 13 452.48 31 15.16 933 438 3.08 / 83.44 2 3
6 8 0.32 180 15.25 288 791 3.87 / 84.23 2 2
Average= 3.66
(KJ/cycle)

Cycle 21 GMT 6/ 7/2021 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 26 15.19 480 190 0.19 / 76.55 2 2
2 7 2003.20 32 14.93 2962 1415 1.60 / 77.97 2 3
3 13 1571.76 31 14.93 2394 1108 2.71 / 79.08 2 4
4 13 433.72 31 15.17 902 424 3.14 / 79.50 2 3
5 8 0.08 180 15.25 288 791 3.93 / 80.29 2 2
6 14 0.08 15 15.24 289 66 3.99 / 80.36 2 2
Average= 3.65
(KJ/cycle)

Cycle 20 GMT 26/ 6/2021 11:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 26 15.20 469 185 0.19 / 72.79 2 2
2 7 2008.08 32 14.93 2969 1418 1.60 / 74.21 2 3
3 13 1453.48 27 14.98 2251 910 2.51 / 75.12 2 3
4 13 545.28 27 15.16 1058 433 2.95 / 75.55 2 3
5 8 0.12 180 15.26 295 810 3.76 / 76.36 2 2
Average= 3.64
(KJ/cycle)

Cycle 19 GMT 16/ 6/2021 13:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 26 15.21 487 193 0.19 / 68.93 2 2
2 7 2004.96 32 14.93 2961 1415 1.61 / 70.34 2 3
3 13 1454.80 27 14.97 2255 911 2.52 / 71.25 2 3
4 13 515.36 27 15.16 1020 418 2.94 / 71.67 2 3
5 13 50.68 5 15.29 369 28 2.96 / 71.70 2 2
6 13 40.72 5 15.30 351 27 2.99 / 71.73 2 2
7 8 0.00 180 15.25 296 813 3.80 / 72.54 2 2
8 14 0.00 15 15.24 294 67 3.87 / 72.61 2 2
Average= 3.63
(KJ/cycle)

Cycle 18 GMT 6/ 6/2021 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 26 15.22 477 189 0.19 / 65.29 2 2
2 7 2002.84 32 14.94 2967 1418 1.61 / 66.71 2 4
3 13 1314.40 27 15.00 2080 842 2.45 / 67.55 2 5
4 13 435.44 27 15.20 909 373 2.82 / 67.92 2 3
5 8 0.20 180 15.28 295 811 3.63 / 68.74 2 2
Average= 3.62
(KJ/cycle)

Cycle 17 GMT 27/ 5/2021 16:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 26 15.22 476 188 0.19 / 61.50 2 2
2 7 2006.16 32 14.95 2969 1420 1.61 / 62.92 2 2
3 13 1443.80 27 14.99 2244 908 2.52 / 63.83 2 3
4 13 537.68 27 15.17 1048 429 2.95 / 64.26 2 3
5 13 55.76 5 15.32 375 29 2.97 / 64.29 2 2
6 8 0.20 180 15.28 295 811 3.79 / 65.10 2 2
Average= 3.62
(KJ/cycle)

Cycle 16 GMT 17/ 5/2021 18:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 26 15.21 465 184 0.18 / 57.64 2 2
2 7 2003.48 32 14.95 2971 1421 1.61 / 59.06 2 3
3 13 1571.16 27 14.98 2402 972 2.58 / 60.04 2 3
4 13 627.16 27 15.17 1169 479 3.06 / 60.51 2 3
5 8 -0.04 180 15.28 291 800 3.86 / 61.31 2 2
Average= 3.61
(KJ/cycle)

Cycle 15 GMT 7/ 5/2021 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 26 15.23 477 189 0.19 / 53.75 2 2
2 7 2003.88 33 14.94 2969 1464 1.65 / 55.21 2 3
3 13 1426.36 27 15.00 2223 900 2.55 / 56.11 2 3
4 13 617.88 27 15.15 1156 473 3.03 / 56.58 2 3
5 8 0.20 180 15.28 294 809 3.83 / 57.39 2 2
6 14 0.20 15 15.26 295 68 3.90 / 57.46 2 2
Average= 3.59
(KJ/cycle)

Cycle 14 GMT 27/ 4/2021 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 26 15.22 469 186 0.19 / 50.03 2 2
2 7 2001.24 32 14.96 2957 1416 1.60 / 51.44 2 3
3 13 1430.84 27 15.01 2227 903 2.50 / 52.34 2 4
4 13 479.48 27 15.20 977 401 2.90 / 52.74 2 3
5 8 0.36 180 15.29 295 812 3.72 / 53.56 2 2
Average= 3.57
(KJ/cycle)

Cycle 13 GMT 18/ 4/2021 1: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 26 15.21 492 195 0.19 / 46.26 2 2
2 7 2002.80 32 14.96 2961 1417 1.61 / 47.67 2 3
3 13 1443.88 26 15.00 2241 874 2.49 / 48.55 2 3
4 13 548.28 26 15.17 1064 420 2.91 / 48.97 2 3
5 8 -0.08 180 15.28 293 806 3.71 / 49.77 2 2
6 14 -0.08 15 15.27 292 67 3.78 / 49.84 2 2
Average= 3.56
(KJ/cycle)

Cycle 12 GMT 8/ 4/2021 2:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 25 15.22 486 185 0.18 / 42.30 2 2
2 3 1018.20 1 15.29 1794 27 0.21 / 42.33 2 2
3 7 2006.64 33 14.95 2969 1465 1.68 / 43.79 2 3
4 13 1560.20 25 14.98 2387 894 2.57 / 44.69 2 5
5 13 727.60 25 15.14 1304 494 3.06 / 45.18 2 4
6 8 -0.32 180 15.28 296 814 3.88 / 45.99 2 2
7 14 -0.32 15 15.27 297 68 3.95 / 46.06 2 2
Average= 3.54
(KJ/cycle)

Cycle 11 GMT 29/ 3/2021 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 25 15.22 484 184 0.18 / 38.54 2 2
2 7 2005.08 32 14.97 2963 1419 1.60 / 39.96 2 3
3 13 1571.64 25 15.00 2420 907 2.51 / 40.87 2 3
4 13 516.16 25 15.19 1021 388 2.90 / 41.26 2 3
5 13 19.64 5 15.35 318 24 2.92 / 41.28 2 2
6 8 0.24 180 15.29 303 834 3.76 / 42.12 2 2
Average= 3.51
(KJ/cycle)

Cycle 10 GMT 19/ 3/2021 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 25 15.21 493 187 0.19 / 34.90 2 2
2 7 2002.40 32 14.96 2969 1421 1.61 / 36.32 2 3
3 13 1429.44 25 15.02 2229 837 2.45 / 37.16 2 2
4 13 508.48 25 15.20 1012 385 2.83 / 37.54 2 3
5 8 0.24 180 15.29 296 815 3.64 / 38.36 2 2
Average= 3.49
(KJ/cycle)

Cycle 9 GMT 9/ 3/2021 8:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 25 15.23 464 177 0.18 / 31.08 2 2
2 3 1025.20 1 15.26 1810 28 0.20 / 31.10 2 2
3 7 2003.28 32 14.96 2966 1420 1.62 / 32.52 2 3
4 13 1445.24 25 15.01 2254 846 2.47 / 33.37 2 4
5 13 676.36 25 15.15 1233 467 2.94 / 33.84 2 3
6 13 29.20 25 15.32 323 124 3.06 / 33.96 2 2
7 8 -0.08 165 15.28 299 754 3.81 / 34.71 2 2
Average= 3.47
(KJ/cycle)

Cycle 8 GMT 27/ 2/2021 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 25 15.23 483 184 0.18 / 27.30 2 2
2 10 1020.64 2 15.16 1765 54 0.24 / 27.35 2 2
3 3 936.52 -2 15.55 0 0 0.05 / 27.35 2 2
4 7 2004.08 32 14.98 2961 1419 1.66 / 28.77 2 3
5 13 1453.76 25 15.02 2264 850 2.51 / 29.62 2 3
6 13 542.52 25 15.20 1055 401 2.91 / 30.02 2 4
7 8 0.44 165 15.30 295 745 3.65 / 30.76 2 2
8 14 0.44 30 15.28 294 135 3.79 / 30.90 2 2
Average= 3.43
(KJ/cycle)

Cycle 7 GMT 17/ 2/2021 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 24 15.23 481 176 0.18 / 23.74 2 2
2 3 1018.56 1 15.28 1757 27 0.20 / 23.77 2 3
3 7 2003.20 32 14.97 2959 1417 1.62 / 25.18 2 3
4 13 1327.92 18 15.07 2099 569 2.19 / 25.75 2 3
5 13 659.60 18 15.19 1214 332 2.52 / 26.09 2 3
6 13 145.60 18 15.30 523 144 2.67 / 26.23 2 3
7 8 -0.16 165 15.30 296 747 3.41 / 26.98 2 2
8 14 -0.16 30 15.28 293 134 3.55 / 27.11 2 2
Average= 3.39
(KJ/cycle)

Cycle 6 GMT 7/ 2/2021 13:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 22 15.23 482 161 0.16 / 20.09 2 2
2 10 1040.92 3 15.13 1777 81 0.24 / 20.17 2 3
3 7 2003.96 32 14.98 2971 1424 1.67 / 21.60 2 5
4 13 1565.68 18 15.02 2408 651 2.32 / 22.25 2 3
5 13 826.12 18 15.15 1440 393 2.71 / 22.64 2 4
6 13 233.44 18 15.29 642 177 2.89 / 22.82 2 3
7 8 0.04 165 15.30 296 747 3.63 / 23.56 2 2
Average= 3.37
(KJ/cycle)

Cycle 5 GMT 28/ 1/2021 15:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 28 15.23 480 205 0.20 / 15.81 2 2
2 3 862.60 -3 15.56 0 0 0.00 / 15.81 2 2
3 3 937.32 -1 15.57 0 0 0.00 / 15.81 2 2
4 7 2003.28 74 14.81 2948 3231 3.44 / 19.04 2 3
5 13 135.08 18 15.29 506 139 3.57 / 19.18 2 3
6 8 0.00 165 15.30 296 747 4.32 / 19.93 2 2
Average= 3.32
(KJ/cycle)

Cycle 4 GMT 18/ 1/2021 17:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 23 15.24 488 171 0.17 / 12.15 2 2
2 3 1028.20 1 15.25 1808 28 0.20 / 12.18 2 4
3 7 1515.60 74 14.97 2314 2563 2.76 / 14.74 2 5
4 13 91.32 18 15.31 433 119 2.88 / 14.86 2 3
5 8 0.04 165 15.30 296 747 3.63 / 15.61 2 2
Average= 3.12
(KJ/cycle)

Cycle 3 GMT 17/ 1/2021 18:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 19 15.25 472 137 0.14 / 8.40 2 2
2 10 1066.52 3 15.13 1825 83 0.22 / 8.48 2 3
3 3 1054.68 2 15.22 1835 56 0.28 / 8.54 2 3
4 7 1524.48 74 14.96 2323 2572 2.85 / 11.11 2 6
5 13 93.96 18 15.31 439 121 2.97 / 11.23 2 2
6 8 -0.16 165 15.30 297 750 3.72 / 11.98 2 2
Average= 2.99
(KJ/cycle)

Cycle 2 GMT 16/ 1/2021 18:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 30 15.30 477 219 0.22 / 4.82 2 2
2 3 733.60 -5 15.58 0 0 0.00 / 4.82 2 2
3 3 864.56 -3 15.59 0 0 0.00 / 4.82 2 2
4 7 1506.84 75 14.97 2299 2581 2.80 / 7.40 2 3
5 13 80.96 18 15.32 419 116 2.92 / 7.52 2 2
6 8 0.04 165 15.31 294 743 3.66 / 8.26 2 2
Average= 2.75
(KJ/cycle)

Cycle 1 GMT 15/ 1/2021 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 26 15.42 457 183 0.18 / 2.04 2 2
2 3 888.04 -2 15.60 0 0 0.00 / 2.04 2 2
3 3 950.40 -1 15.62 0 0 0.00 / 2.04 2 2
4 7 976.96 75 15.15 1604 1823 2.01 / 3.86 2 6
5 8 0.12 165 15.36 292 740 2.75 / 4.60 2 2
Average= 2.30
(KJ/cycle)

Cycle 0 GMT 15/ 1/2021 8:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 146.92 25 15.55 526 204 0.20 / 0.20 2 2
2 7 161.16 74 15.51 517 593 0.80 / 0.80 2 2
3 8 -0.08 240 15.49 285 1060 1.86 / 1.86 2 3
Average= 1.86
(KJ/cycle)