SIO Argo Site:
Pump Diagnostics Page   



Serial= 8757 WMO= 7900793

Return

←PreviousNext→

Cycle 198 GMT 17/ 3/2024 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.88 25 14.96 654 245 0.24 / 728.54 2 3
2 7 1629.16 28 15.00 2497 1049 1.29 / 729.59 2 3
3 13 1595.84 18 14.95 2469 664 1.96 / 730.25 2 4
4 13 979.32 18 14.99 1701 459 2.42 / 730.71 2 6
5 13 358.12 14 15.07 902 190 2.61 / 730.90 2 7
6 13 58.16 5 15.12 522 39 2.65 / 730.94 2 8
7 13 19.48 9 15.12 468 64 2.71 / 731.00 2 8
8 8 0.32 165 15.06 420 1044 3.75 / 732.05 2 17
Average= 3.68
(KJ/cycle)

Cycle 197 GMT 7/ 3/2024 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.92 25 14.99 669 251 0.25 / 724.57 2 3
2 7 1928.28 28 14.93 2852 1192 1.44 / 725.76 2 2
3 13 1572.80 18 14.91 2451 658 2.10 / 726.42 2 5
4 13 943.88 18 14.95 1664 448 2.55 / 726.86 2 6
5 13 505.32 18 15.00 1100 297 2.85 / 727.16 2 7
6 13 40.04 18 15.10 482 131 2.98 / 727.29 2 9
7 8 0.00 165 15.04 404 1003 3.98 / 728.29 2 19
Average= 3.68
(KJ/cycle)

Cycle 196 GMT 26/ 2/2024 21:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.56 25 14.91 666 248 0.25 / 720.76 2 3
2 3 1016.44 1 15.11 1798 27 0.28 / 720.79 2 2
3 7 1525.96 28 14.99 2376 997 1.27 / 721.78 2 2
4 13 1493.88 18 14.94 2333 627 1.90 / 722.41 2 4
5 13 1012.36 18 14.98 1741 469 2.37 / 722.88 2 6
6 13 329.96 18 15.09 874 237 2.61 / 723.12 2 6
7 13 35.52 18 15.14 482 131 2.74 / 723.25 2 8
8 8 0.16 165 15.08 428 1065 3.80 / 724.32 2 19
Average= 3.68
(KJ/cycle)

Cycle 195 GMT 25/ 2/2024 22:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.16 25 14.86 642 239 0.24 / 716.99 2 3
2 3 985.20 -1 15.39 5 0 0.00 / 716.99 2 3
3 7 1528.40 29 14.98 2365 1027 1.27 / 718.02 2 2
4 13 1499.64 18 14.93 2339 629 1.89 / 718.65 2 4
5 13 992.88 18 14.97 1724 465 2.36 / 719.11 2 6
6 13 330.76 18 15.08 866 235 2.59 / 719.35 2 7
7 13 37.44 18 15.13 476 130 2.72 / 719.48 2 8
8 8 0.16 165 15.08 416 1035 3.76 / 720.51 2 20
Average= 3.68
(KJ/cycle)

Cycle 194 GMT 24/ 2/2024 22:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.04 24 14.94 672 241 0.24 / 712.90 2 3
2 3 1038.32 1 15.00 1830 27 0.27 / 712.93 2 2
3 7 2009.52 29 14.90 2943 1272 1.54 / 714.20 2 2
4 13 1617.60 18 14.89 2497 669 2.21 / 714.87 2 4
5 13 1077.20 18 14.91 1829 491 2.70 / 715.36 2 5
6 13 425.60 18 15.02 986 267 2.97 / 715.62 2 7
7 13 58.12 18 15.09 495 134 3.10 / 715.76 2 8
8 8 -0.16 165 15.04 401 995 4.10 / 716.75 2 18
Average= 3.68
(KJ/cycle)

Cycle 193

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.32 13 14.94 675 131 0.13 / 708.27 2 2
2 10 1073.16 6 14.86 1904 170 0.30 / 708.44 2 2
3 10 1126.04 4 14.86 1972 117 0.42 / 708.55 2 2
4 3 1145.72 4 14.90 1977 118 0.54 / 708.67 2 2
5 7 2002.92 28 14.90 2944 1228 1.76 / 709.90 2 2
6 13 1547.52 18 14.90 2395 642 2.41 / 710.54 2 4
7 13 1066.80 18 14.91 1809 485 2.89 / 711.03 2 6
8 13 455.84 18 15.00 1033 279 3.17 / 711.31 2 7
9 13 45.04 18 15.09 486 132 3.30 / 711.44 2 8
10 8 0.36 165 15.04 406 1008 4.31 / 712.45 2 18
11 14 0.36 35 15.01 401 211 4.52 / 712.66 2 21
Average= 3.67
(KJ/cycle)

Cycle 192 GMT 5/ 2/2024 6:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.56 13 15.05 683 134 0.13 / 704.37 2 2
2 7 2003.56 28 14.89 2938 1225 1.36 / 705.60 2 2
3 13 1634.80 18 14.87 2513 673 2.03 / 706.27 2 3
4 13 1042.48 18 14.90 1796 482 2.51 / 706.75 2 5
5 13 443.88 18 15.00 1023 276 2.79 / 707.03 2 7
6 13 56.92 5 15.09 518 39 2.83 / 707.07 2 7
7 13 41.32 5 15.09 509 38 2.87 / 707.11 2 8
8 8 0.16 165 15.04 415 1030 3.90 / 708.14 2 17
Average= 3.67
(KJ/cycle)

Cycle 191

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.24 14 15.05 662 139 0.14 / 701.57 2 2
2 3 979.40 -1 15.36 4 0 0.00 / 701.57 2 2
3 7 2004.84 28 14.89 2948 1229 1.37 / 702.80 2 2
4 13 1552.88 18 14.88 2428 650 2.02 / 703.45 2 4
5 13 1026.88 18 14.91 1763 473 2.49 / 703.93 2 5
6 13 438.24 18 15.00 1022 276 2.77 / 704.20 2 7
7 13 46.88 5 15.10 504 38 2.81 / 704.24 2 7
Average= 3.67
(KJ/cycle)

Cycle 190

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.40 13 15.05 681 133 0.13 / 698.76 2 2
2 7 2005.12 28 14.89 2946 1228 1.36 / 699.99 2 2
3 13 1595.92 18 14.88 2470 662 2.02 / 700.65 2 4
4 13 1051.00 18 14.90 1791 480 2.50 / 701.13 2 6
5 13 378.84 15 15.02 930 210 2.71 / 701.34 2 7
6 13 90.04 6 15.09 562 51 2.76 / 701.40 2 7
7 13 40.44 5 15.10 503 38 2.80 / 701.43 2 7
Average= 3.67
(KJ/cycle)

Cycle 189

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.16 14 15.05 680 143 0.14 / 696.00 2 2
2 7 2003.00 28 14.89 2940 1226 1.37 / 697.22 2 2
3 13 1590.52 18 14.88 2467 661 2.03 / 697.88 2 4
4 13 1009.40 18 14.91 1750 470 2.50 / 698.35 2 6
5 13 387.52 15 15.02 961 217 2.72 / 698.57 2 6
6 13 94.80 7 15.09 575 61 2.78 / 698.63 2 7
Average= 3.68
(KJ/cycle)

Cycle 188

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.76 13 15.05 665 130 0.13 / 693.12 2 2
2 10 1000.72 2 15.01 1812 54 0.18 / 693.18 2 3
3 3 933.08 -2 15.36 4 0 0.05 / 693.18 2 3
4 7 2003.60 28 14.91 2941 1228 1.41 / 694.40 2 2
5 13 1595.36 18 14.88 2453 657 2.07 / 695.06 2 3
6 13 1033.68 18 14.91 1773 476 2.55 / 695.54 2 6
7 13 447.32 18 15.00 1030 278 2.82 / 695.82 2 6
8 13 59.32 5 15.10 519 39 2.86 / 695.85 2 7
Average= 3.68
(KJ/cycle)

Cycle 187

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.56 13 15.05 677 132 0.13 / 690.37 2 2
2 7 2005.56 28 14.90 2951 1231 1.36 / 691.60 2 2
3 13 1548.88 18 14.88 2412 646 2.01 / 692.25 2 4
4 13 1065.24 18 14.91 1821 489 2.50 / 692.73 2 5
5 13 370.80 15 15.03 921 208 2.71 / 692.94 2 6
6 13 81.08 6 15.09 550 50 2.76 / 692.99 2 8
Average= 3.69
(KJ/cycle)

Cycle 186

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.88 13 15.05 685 134 0.13 / 687.36 2 2
2 3 1041.52 1 15.02 1861 28 0.16 / 687.39 2 2
3 7 2004.80 28 14.90 2946 1229 1.39 / 688.62 2 2
4 13 1816.48 18 14.85 2734 731 2.12 / 689.35 2 3
5 13 1179.40 18 14.87 1960 525 2.65 / 689.87 2 5
6 13 549.44 18 14.97 1171 316 2.96 / 690.19 2 6
7 13 68.96 6 15.09 536 49 3.01 / 690.24 2 7
Average= 3.69
(KJ/cycle)

Cycle 185

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.76 14 15.05 659 139 0.14 / 684.55 2 3
2 3 937.64 -2 15.37 4 0 0.00 / 684.55 2 3
3 7 2003.32 28 14.89 2944 1227 1.37 / 685.78 2 2
4 13 1637.68 18 14.87 2518 674 2.04 / 686.45 2 3
5 13 999.84 18 14.91 1738 466 2.51 / 686.92 2 5
6 13 428.68 18 15.00 1002 271 2.78 / 687.19 2 7
7 13 53.04 5 15.10 514 39 2.82 / 687.23 2 7
Average= 3.69
(KJ/cycle)

Cycle 184

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.96 13 15.05 674 132 0.13 / 681.66 2 2
2 10 1022.84 2 14.99 1827 55 0.19 / 681.71 2 2
3 3 974.92 -1 15.36 5 0 0.05 / 681.71 2 2
4 7 2005.68 28 14.90 2952 1232 1.42 / 682.94 2 2
5 13 1602.92 18 14.88 2471 662 2.08 / 683.61 2 3
6 13 1030.04 18 14.90 1769 474 2.55 / 684.08 2 5
7 13 474.32 18 14.99 1071 289 2.84 / 684.37 2 7
8 13 56.92 5 15.09 531 40 2.88 / 684.41 2 7
Average= 3.70
(KJ/cycle)

Cycle 183

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.80 13 15.05 666 130 0.13 / 678.79 2 3
2 3 971.68 -1 15.37 4 0 0.00 / 678.79 2 3
3 7 2006.68 28 14.89 2950 1230 1.36 / 680.02 2 2
4 13 1680.68 18 14.87 2584 692 2.05 / 680.71 2 4
5 13 999.40 18 14.91 1732 465 2.52 / 681.18 2 5
6 13 467.52 18 15.00 1054 285 2.80 / 681.46 2 7
7 13 128.48 7 15.08 621 66 2.87 / 681.53 2 7
Average= 3.70
(KJ/cycle)

Cycle 182

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.00 14 15.06 658 139 0.14 / 676.02 2 3
2 3 966.08 -1 15.37 4 0 0.00 / 676.02 2 3
3 7 2003.08 28 14.89 2930 1222 1.36 / 677.25 2 2
4 13 1586.24 18 14.88 2452 657 2.02 / 677.90 2 4
5 13 1059.60 18 14.91 1810 486 2.50 / 678.39 2 5
6 13 422.44 18 15.01 1004 271 2.77 / 678.66 2 7
Average= 3.71
(KJ/cycle)

Cycle 181

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.48 13 15.05 672 131 0.13 / 673.12 2 2
2 3 1059.56 2 15.02 1881 57 0.19 / 673.18 2 2
3 7 2004.40 28 14.90 2947 1229 1.42 / 674.40 2 2
4 13 1646.24 18 14.87 2550 683 2.10 / 675.09 2 3
5 13 1000.24 18 14.91 1749 469 2.57 / 675.56 2 5
6 13 459.04 18 15.00 1044 282 2.85 / 675.84 2 7
7 13 62.08 6 15.10 519 47 2.90 / 675.89 2 7
Average= 3.71
(KJ/cycle)

Cycle 180

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.20 12 15.06 666 120 0.12 / 670.26 2 2
2 10 1000.80 2 15.00 1809 54 0.17 / 670.32 2 3
3 3 952.12 -2 15.37 4 0 0.05 / 670.32 2 3
4 7 2006.88 28 14.90 2943 1228 1.40 / 671.54 2 2
5 13 1644.56 18 14.88 2518 674 2.08 / 672.22 2 4
6 13 1002.76 18 14.92 1742 468 2.54 / 672.69 2 5
7 13 382.20 15 15.02 954 215 2.76 / 672.90 2 6
8 13 65.72 6 15.10 531 48 2.81 / 672.95 2 7
9 13 45.32 5 15.09 512 39 2.85 / 672.99 2 8
Average= 3.72
(KJ/cycle)

Cycle 179

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.00 14 15.06 671 141 0.14 / 667.47 2 3
2 3 956.08 -2 15.37 4 0 0.00 / 667.47 2 3
3 7 2004.80 28 14.90 2930 1222 1.36 / 668.70 2 2
4 13 1600.56 18 14.88 2457 658 2.02 / 669.35 2 4
5 13 1011.56 18 14.92 1742 468 2.49 / 669.82 2 5
6 13 421.52 18 15.01 1002 271 2.76 / 670.09 2 6
7 13 69.88 6 15.10 533 48 2.81 / 670.14 2 7
Average= 3.72
(KJ/cycle)

Cycle 178

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.32 13 15.06 675 132 0.13 / 664.61 2 2
2 3 1019.84 1 15.06 1835 28 0.16 / 664.64 2 2
3 7 2004.88 29 14.90 2934 1268 1.43 / 665.91 2 2
4 13 1594.24 18 14.87 2482 664 2.09 / 666.57 2 4
5 13 1000.36 18 14.91 1742 468 2.56 / 667.04 2 5
6 13 495.52 18 14.99 1090 294 2.85 / 667.33 2 7
Average= 3.73
(KJ/cycle)

Cycle 177

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.48 13 15.05 680 133 0.13 / 661.85 2 3
2 7 2003.96 28 14.90 2927 1221 1.35 / 663.07 2 2
3 13 1597.72 18 14.88 2474 663 2.02 / 663.73 2 4
4 13 1016.28 18 14.92 1761 473 2.49 / 664.20 2 5
5 13 383.80 15 15.03 945 213 2.70 / 664.42 2 7
6 13 100.64 7 15.09 578 61 2.76 / 664.48 2 7
Average= 3.73
(KJ/cycle)

Cycle 176

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.32 13 15.06 666 130 0.13 / 659.12 2 3
2 7 2003.60 28 14.90 2943 1228 1.36 / 660.35 2 2
3 13 1590.36 18 14.89 2461 660 2.02 / 661.01 2 4
4 13 1002.08 18 14.92 1751 470 2.49 / 661.48 2 5
5 13 336.08 14 15.05 881 186 2.67 / 661.67 2 6
6 13 74.16 6 15.10 541 49 2.72 / 661.71 2 7
Average= 3.74
(KJ/cycle)

Cycle 175

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.80 14 15.06 671 141 0.14 / 656.29 2 3
2 3 973.00 -1 15.38 4 0 0.00 / 656.29 2 3
3 7 2003.56 28 14.89 2951 1230 1.37 / 657.52 2 2
4 13 1638.64 18 14.88 2528 677 2.05 / 658.19 2 3
5 13 1013.36 18 14.91 1766 474 2.52 / 658.67 2 5
6 13 435.60 18 15.01 1016 275 2.80 / 658.94 2 7
7 13 72.08 6 15.09 547 50 2.85 / 658.99 2 7
Average= 3.74
(KJ/cycle)

Cycle 174

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.00 14 15.06 681 144 0.14 / 653.55 2 3
2 7 2004.32 28 14.89 2949 1229 1.37 / 654.78 2 2
3 13 1547.68 18 14.89 2406 645 2.02 / 655.42 2 4
4 13 968.60 18 14.93 1684 453 2.47 / 655.88 2 5
5 13 391.36 15 15.02 960 216 2.69 / 656.09 2 6
6 13 89.64 6 15.10 572 52 2.74 / 656.15 2 7
Average= 3.75
(KJ/cycle)

Cycle 173

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.36 15 15.05 690 156 0.16 / 650.70 2 3
2 3 940.68 -2 15.37 4 0 0.00 / 650.70 2 3
3 7 2002.64 28 14.91 2949 1231 1.39 / 651.93 2 2
4 13 1588.00 18 14.88 2460 659 2.05 / 652.59 2 3
5 13 1045.64 18 14.92 1799 483 2.53 / 653.07 2 5
6 13 457.20 18 15.01 1051 284 2.81 / 653.36 2 7
7 13 63.24 6 15.10 537 49 2.86 / 653.41 2 7
Average= 3.76
(KJ/cycle)

Cycle 172

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.32 13 15.07 663 130 0.13 / 647.73 2 2
2 10 1036.44 2 15.00 1863 56 0.19 / 647.79 2 3
3 7 2004.32 29 14.90 2947 1273 1.46 / 649.06 2 2
4 13 1600.64 18 14.88 2484 665 2.12 / 649.73 2 4
5 13 1058.04 18 14.91 1811 486 2.61 / 650.21 2 6
6 13 458.48 18 15.01 1057 286 2.90 / 650.50 2 7
7 13 61.68 6 15.10 533 48 2.94 / 650.54 2 7
Average= 3.76
(KJ/cycle)

Cycle 171

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.32 13 15.06 669 131 0.13 / 644.86 2 3
2 7 2002.96 28 14.90 2926 1221 1.35 / 646.08 2 2
3 13 1637.16 18 14.88 2514 673 2.03 / 646.75 2 4
4 13 930.68 18 14.94 1640 441 2.47 / 647.19 2 5
5 13 538.00 18 14.99 1148 310 2.78 / 647.50 2 6
6 13 77.48 6 15.10 546 49 2.83 / 647.55 2 7
7 13 61.28 6 15.10 525 48 2.87 / 647.60 2 8
Average= 3.77
(KJ/cycle)

Cycle 170

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.64 13 15.06 672 132 0.13 / 642.04 2 3
2 7 2005.96 28 14.90 2941 1227 1.36 / 643.26 2 2
3 13 1595.20 18 14.89 2469 662 2.02 / 643.93 2 4
4 13 1019.68 18 14.92 1754 471 2.49 / 644.40 2 5
5 13 460.96 18 15.01 1045 282 2.77 / 644.68 2 7
6 13 68.88 6 15.10 533 48 2.82 / 644.73 2 7
Average= 3.77
(KJ/cycle)

Cycle 169

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.16 13 15.06 677 133 0.13 / 639.27 2 3
2 7 2008.64 28 14.90 2936 1225 1.36 / 640.49 2 2
3 13 1563.68 18 14.89 2428 651 2.01 / 641.14 2 4
4 13 953.84 18 14.93 1668 448 2.46 / 641.59 2 5
5 13 418.20 18 15.02 983 266 2.72 / 641.86 2 6
6 13 69.16 6 15.10 529 48 2.77 / 641.91 2 7
Average= 3.78
(KJ/cycle)

Cycle 168

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.36 13 15.07 662 130 0.13 / 636.51 2 3
2 7 2004.84 28 14.90 2935 1224 1.35 / 637.73 2 2
3 13 1637.24 18 14.88 2521 675 2.03 / 638.41 2 4
4 13 936.52 18 14.94 1655 445 2.47 / 638.86 2 5
5 13 364.84 14 15.05 913 192 2.67 / 639.05 2 6
6 13 80.48 6 15.11 552 50 2.72 / 639.10 2 8
7 13 48.48 5 15.11 503 38 2.75 / 639.14 2 8
Average= 3.78
(KJ/cycle)

Cycle 167

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.16 13 15.07 657 129 0.13 / 633.70 2 2
2 3 1019.52 1 15.11 1836 28 0.16 / 633.73 2 2
3 7 2006.00 28 14.90 2940 1227 1.38 / 634.95 2 2
4 13 1688.04 18 14.88 2578 690 2.07 / 635.64 2 4
5 13 997.04 18 14.93 1729 465 2.54 / 636.11 2 5
6 13 375.28 15 15.04 925 209 2.75 / 636.32 2 6
7 13 125.08 7 15.10 605 64 2.81 / 636.38 2 7
Average= 3.79
(KJ/cycle)

Cycle 166

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.12 14 15.07 645 136 0.14 / 630.88 2 3
2 3 952.40 -2 15.38 4 0 0.00 / 630.88 2 3
3 7 2002.68 28 14.90 2930 1222 1.36 / 632.10 2 2
4 13 1631.12 18 14.89 2516 674 2.03 / 632.78 2 4
5 13 967.36 18 14.93 1692 455 2.49 / 633.23 2 6
6 13 487.84 18 15.01 1075 290 2.78 / 633.52 2 7
7 13 71.40 6 15.11 531 48 2.83 / 633.57 2 7
Average= 3.79
(KJ/cycle)

Cycle 165

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.16 24 15.06 652 236 0.24 / 628.08 2 6
2 3 608.32 -14 15.38 4 0 0.00 / 628.08 2 6
3 3 948.80 -2 15.42 4 0 0.00 / 628.08 2 6
4 7 2005.56 28 14.91 2935 1225 1.46 / 629.30 2 2
5 13 1590.72 18 14.90 2459 660 2.12 / 629.96 2 4
6 13 979.48 18 14.93 1703 458 2.58 / 630.42 2 5
7 13 483.76 18 15.01 1065 288 2.87 / 630.71 2 6
8 13 55.00 5 15.12 499 38 2.90 / 630.74 2 8
Average= 3.80
(KJ/cycle)

Cycle 164

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.72 24 14.98 674 242 0.24 / 625.15 2 3
2 7 2003.28 28 14.93 2942 1230 1.47 / 626.38 2 2
3 13 1633.84 18 14.91 2508 673 2.15 / 627.06 2 4
4 13 1003.36 18 14.94 1724 464 2.61 / 627.52 2 6
5 13 467.76 18 15.03 1040 281 2.89 / 627.80 2 6
6 13 49.92 5 15.13 496 38 2.93 / 627.84 2 7
Average= 3.81
(KJ/cycle)

Cycle 163 GMT 26/ 4/2023 19:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.04 25 14.99 659 247 0.25 / 621.24 2 3
2 3 977.88 -1 15.36 4 0 0.00 / 621.24 2 3
3 7 2003.72 28 14.92 2933 1225 1.47 / 622.46 2 2
4 13 1583.88 18 14.91 2445 656 2.13 / 623.12 2 4
5 13 1048.44 18 14.94 1782 479 2.61 / 623.60 2 5
6 13 448.88 18 15.03 1015 275 2.88 / 623.87 2 6
7 13 50.08 5 15.13 502 38 2.92 / 623.91 2 8
8 8 0.20 165 15.07 402 1000 3.92 / 624.91 2 17
Average= 3.81
(KJ/cycle)

Cycle 162 GMT 16/ 4/2023 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.40 24 14.99 644 232 0.23 / 617.31 2 3
2 10 1021.28 2 14.98 1811 54 0.29 / 617.36 2 3
3 3 976.76 -1 15.35 4 0 0.05 / 617.36 2 3
4 7 2004.00 28 14.93 2935 1227 1.51 / 618.59 2 2
5 13 1609.24 18 14.91 2467 662 2.17 / 619.25 2 4
6 13 941.88 18 14.95 1649 444 2.62 / 619.70 2 5
7 13 457.80 18 15.02 1027 278 2.90 / 619.97 2 6
8 8 0.28 165 15.07 410 1019 3.92 / 620.99 2 17
Average= 3.81
(KJ/cycle)

Cycle 161 GMT 7/ 4/2023 3:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.60 24 14.99 631 227 0.23 / 613.38 2 3
2 7 2003.76 29 14.93 2928 1268 1.49 / 614.64 2 2
3 13 1598.16 18 14.91 2453 658 2.15 / 615.30 2 4
4 13 1003.68 18 14.95 1723 464 2.62 / 615.77 2 5
5 13 454.20 18 15.03 1015 275 2.89 / 616.04 2 6
6 13 59.88 5 15.13 509 39 2.93 / 616.08 2 7
7 8 -0.04 165 15.08 401 998 3.93 / 617.08 2 17
Average= 3.81
(KJ/cycle)

Cycle 160 GMT 28/ 3/2023 8:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.44 24 14.99 654 235 0.24 / 609.46 2 3
2 3 1020.84 1 15.06 1817 27 0.26 / 609.49 2 2
3 7 2004.44 28 14.93 2923 1222 1.48 / 610.71 2 2
4 13 1560.12 18 14.92 2414 648 2.13 / 611.36 2 4
5 13 1017.72 18 14.95 1738 468 2.60 / 611.82 2 6
6 13 467.48 18 15.03 1035 280 2.88 / 612.10 2 6
7 13 72.24 6 15.12 521 47 2.93 / 612.15 2 7
8 8 0.08 165 15.07 401 997 3.92 / 613.15 2 15
Average= 3.81
(KJ/cycle)

Cycle 159 GMT 18/ 3/2023 12:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.48 24 14.99 629 226 0.23 / 605.40 2 3
2 3 966.84 -1 15.36 4 0 0.00 / 605.40 2 3
3 7 2003.20 28 14.93 2945 1231 1.46 / 606.63 2 2
4 13 1583.72 18 14.91 2451 658 2.12 / 607.29 2 4
5 13 959.88 18 14.96 1665 448 2.56 / 607.74 2 6
6 13 370.52 15 15.05 913 206 2.77 / 607.95 2 6
7 13 138.36 8 15.10 611 74 2.84 / 608.02 2 7
8 8 0.24 165 15.08 400 995 3.84 / 609.02 2 17
9 14 0.24 35 15.05 396 209 4.05 / 609.22 2 18
Average= 3.81
(KJ/cycle)

Cycle 158 GMT 8/ 3/2023 16:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.96 24 15.00 650 234 0.23 / 601.43 2 3
2 7 2004.76 28 14.92 2942 1229 1.46 / 602.65 2 3
3 13 1608.28 18 14.91 2477 665 2.13 / 603.32 2 4
4 13 1017.52 18 14.95 1742 469 2.60 / 603.79 2 6
5 13 425.00 18 15.04 984 266 2.86 / 604.05 2 6
6 13 36.44 18 15.12 468 127 2.99 / 604.18 2 8
7 8 0.16 165 15.07 400 995 3.98 / 605.18 2 21
Average= 3.81
(KJ/cycle)

Cycle 157 GMT 26/ 2/2023 20:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.44 24 14.98 638 229 0.23 / 597.43 2 3
2 7 2005.20 28 14.93 2941 1229 1.46 / 598.66 2 2
3 13 1594.12 18 14.92 2458 660 2.12 / 599.32 2 3
4 13 1013.68 18 14.95 1740 468 2.59 / 599.79 2 5
5 13 430.80 18 15.04 994 269 2.86 / 600.06 2 6
6 13 41.76 18 15.12 481 131 2.99 / 600.19 2 8
7 8 0.28 165 15.07 404 1005 3.99 / 601.19 2 15
Average= 3.81
(KJ/cycle)

Cycle 156 GMT 17/ 2/2023 1: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.32 23 15.01 650 224 0.22 / 593.20 2 3
2 10 1026.72 2 15.01 1827 55 0.28 / 593.25 2 3
3 3 979.08 -1 15.37 4 0 0.05 / 593.25 2 3
4 7 2003.32 28 14.94 2921 1222 1.50 / 594.48 2 2
5 13 1589.24 18 14.92 2444 656 2.16 / 595.13 2 4
6 13 969.80 18 14.96 1691 455 2.61 / 595.59 2 5
7 13 433.56 18 15.04 1012 274 2.89 / 595.86 2 6
8 13 83.88 18 15.11 538 146 3.03 / 596.01 2 8
9 8 -0.24 165 15.08 395 983 4.02 / 596.99 2 17
10 14 -0.24 35 15.04 399 210 4.23 / 597.20 3 20
Average= 3.80
(KJ/cycle)

Cycle 155 GMT 7/ 2/2023 5:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.48 14 15.05 654 138 0.14 / 588.93 2 2
2 10 1052.16 6 14.94 1859 167 0.30 / 589.10 2 2
3 10 1100.88 3 14.94 1929 86 0.39 / 589.19 2 2
4 3 1085.88 3 15.01 1902 86 0.48 / 589.27 2 2
5 7 2003.60 28 14.95 2929 1226 1.70 / 590.50 2 2
6 13 1591.28 18 14.94 2456 660 2.36 / 591.16 2 4
7 13 1058.16 18 14.96 1796 484 2.85 / 591.64 2 5
8 13 494.80 18 15.04 1079 292 3.14 / 591.93 2 6
9 13 57.36 5 15.14 515 39 3.18 / 591.97 2 7
10 8 0.12 165 15.09 402 1001 4.18 / 592.97 2 15
Average= 3.80
(KJ/cycle)

Cycle 154 GMT 28/ 1/2023 10: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.68 25 14.96 654 245 0.24 / 585.45 2 3
2 3 1017.96 1 15.14 1824 28 0.27 / 585.47 2 2
3 7 1528.56 28 15.02 2362 993 1.27 / 586.47 2 2
4 13 1497.92 18 14.97 2334 629 1.89 / 587.10 2 4
5 13 964.96 18 15.02 1673 452 2.35 / 587.55 2 6
6 13 363.80 14 15.12 911 193 2.54 / 587.74 2 6
7 13 57.92 5 15.18 514 39 2.58 / 587.78 2 7
8 8 0.20 165 15.12 407 1015 3.59 / 588.80 2 15
Average= 3.80
(KJ/cycle)

Cycle 153 GMT 27/ 1/2023 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.96 21 14.94 659 207 0.21 / 581.40 2 2
2 10 1031.44 4 14.91 1834 109 0.32 / 581.51 2 3
3 3 1054.08 2 15.07 1878 57 0.37 / 581.57 2 2
4 7 1526.04 31 14.98 2348 1090 1.46 / 582.66 2 3
5 13 1488.48 28 14.91 2303 961 2.42 / 583.62 2 5
6 13 680.92 28 15.02 1303 548 2.97 / 584.17 2 6
7 13 48.68 5 15.17 492 37 3.01 / 584.20 2 7
8 8 0.04 165 15.12 400 998 4.01 / 585.20 2 16
Average= 3.80
(KJ/cycle)

Cycle 152 GMT 26/ 1/2023 11:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.76 13 15.09 659 129 0.13 / 577.15 2 3
2 3 1044.52 1 15.11 1865 28 0.16 / 577.18 2 3
3 7 2005.44 32 14.89 2937 1399 1.56 / 578.58 2 3
4 13 1594.08 28 14.86 2439 1015 2.57 / 579.59 2 5
5 13 663.76 28 14.98 1298 544 3.12 / 580.14 2 6
6 13 52.76 5 15.13 514 39 3.16 / 580.18 2 7
7 8 -0.04 165 15.08 408 1015 4.17 / 581.19 2 20
Average= 3.80
(KJ/cycle)

Cycle 151

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.64 12 15.08 679 123 0.12 / 573.99 2 3
2 7 2006.60 31 14.90 2941 1358 1.48 / 575.35 2 3
3 13 1589.72 28 14.86 2445 1017 2.50 / 576.36 2 4
4 13 796.96 28 14.95 1461 612 3.11 / 576.97 2 6
5 13 73.36 6 15.12 539 49 3.16 / 577.02 2 8
Average= 3.80
(KJ/cycle)

Cycle 150

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.00 12 15.08 667 121 0.12 / 570.88 2 3
2 7 2011.32 32 14.89 2948 1405 1.53 / 572.29 2 2
3 13 1479.76 28 14.88 2321 967 2.49 / 573.25 2 5
4 13 712.32 28 14.96 1363 571 3.06 / 573.82 2 6
5 13 56.24 5 15.13 522 39 3.10 / 573.86 2 7
Average= 3.80
(KJ/cycle)

Cycle 149

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.32 14 15.09 659 139 0.14 / 567.80 2 4
2 3 949.84 -2 15.45 4 0 0.00 / 567.80 2 4
3 7 2003.40 31 14.91 2931 1355 1.49 / 569.15 2 3
4 13 1595.00 28 14.87 2450 1020 2.51 / 570.17 2 4
5 13 685.12 28 14.98 1317 552 3.07 / 570.72 2 7
6 13 45.96 5 15.14 500 38 3.10 / 570.76 2 8
Average= 3.81
(KJ/cycle)

Cycle 148

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.84 13 15.08 679 133 0.13 / 564.65 2 3
2 3 1042.68 1 15.11 1876 28 0.16 / 564.68 2 3
3 7 2004.24 31 14.90 2944 1360 1.52 / 566.04 2 3
4 13 1608.00 28 14.86 2467 1026 2.55 / 567.06 2 5
5 13 682.40 28 14.98 1319 553 3.10 / 567.62 2 6
6 13 58.44 5 15.14 523 40 3.14 / 567.66 2 7
Average= 3.81
(KJ/cycle)

Cycle 147

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.44 13 15.09 671 132 0.13 / 561.48 2 3
2 3 973.16 -1 15.45 4 0 0.00 / 561.48 2 3
3 7 2002.44 31 14.90 2936 1356 1.49 / 562.84 2 3
4 13 1578.84 28 14.87 2431 1012 2.50 / 563.85 2 4
5 13 791.16 28 14.95 1480 620 3.12 / 564.47 2 6
6 13 66.76 6 15.12 535 49 3.17 / 564.52 2 7
Average= 3.81
(KJ/cycle)

Cycle 146

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.60 12 15.09 678 123 0.12 / 558.33 2 3
2 3 1051.60 2 15.11 1869 56 0.18 / 558.39 2 2
3 7 2003.44 31 14.89 2945 1359 1.54 / 559.75 2 3
4 13 1583.04 28 14.87 2447 1019 2.56 / 560.77 2 4
5 13 663.68 28 14.98 1296 544 3.10 / 561.31 2 6
6 13 53.76 5 15.14 513 39 3.14 / 561.35 2 7
Average= 3.82
(KJ/cycle)

Cycle 145

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.28 15 15.09 693 157 0.16 / 555.21 2 4
2 3 906.12 -3 15.45 4 0 0.00 / 555.21 2 4
3 7 2004.56 31 14.90 2941 1358 1.52 / 556.57 2 3
4 13 1604.72 28 14.87 2470 1028 2.54 / 557.60 2 4
5 13 698.08 28 14.97 1348 565 3.11 / 558.16 2 6
6 13 60.64 6 15.13 527 48 3.16 / 558.21 2 7
Average= 3.82
(KJ/cycle)

Cycle 144

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.04 20 15.07 673 203 0.20 / 552.13 2 5
2 3 772.00 -8 15.45 4 0 0.00 / 552.13 2 5
3 3 973.40 -1 15.48 4 0 0.00 / 552.13 2 5
4 7 2003.56 31 14.90 2931 1354 1.56 / 553.48 2 2
5 13 1584.88 28 14.87 2448 1019 2.58 / 554.50 2 4
6 13 660.80 28 14.98 1314 551 3.13 / 555.05 2 6
Average= 3.83
(KJ/cycle)

Cycle 143

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.80 14 15.08 664 140 0.14 / 548.84 2 2
2 10 1076.56 4 14.97 1905 114 0.25 / 548.95 2 2
3 3 1134.68 4 15.05 1992 120 0.37 / 549.07 2 3
4 7 2005.80 31 14.89 2941 1358 1.73 / 550.43 2 3
5 13 1467.36 28 14.89 2286 953 2.68 / 551.38 2 5
6 13 575.52 28 15.01 1185 498 3.18 / 551.88 2 7
7 13 61.00 6 15.14 520 47 3.23 / 551.92 2 7
Average= 3.83
(KJ/cycle)

Cycle 142

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.20 13 15.09 665 130 0.13 / 545.58 2 3
2 3 1022.68 1 15.13 1835 28 0.16 / 545.61 2 2
3 7 2005.36 31 14.90 2941 1358 1.52 / 546.97 2 3
4 13 1604.52 28 14.86 2463 1025 2.54 / 547.99 2 4
5 13 795.64 28 14.96 1461 612 3.15 / 548.61 2 6
6 13 71.88 6 15.13 542 49 3.20 / 548.66 2 8
7 13 44.56 5 15.13 514 39 3.24 / 548.69 2 8
Average= 3.84
(KJ/cycle)

Cycle 141

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.44 14 15.08 672 142 0.14 / 542.41 2 4
2 3 962.92 -1 15.45 4 0 0.00 / 542.41 2 4
3 7 2004.08 32 14.90 2939 1401 1.54 / 543.81 2 3
4 13 1618.56 28 14.86 2480 1032 2.58 / 544.85 2 4
5 13 672.80 28 14.97 1330 557 3.13 / 545.40 2 7
6 13 78.72 6 15.13 553 50 3.18 / 545.45 2 8
Average= 3.84
(KJ/cycle)

Cycle 140

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.40 15 15.09 671 152 0.15 / 539.17 2 3
2 3 966.80 -1 15.45 5 0 0.00 / 539.17 2 3
3 7 2008.44 31 14.90 2953 1364 1.52 / 540.53 2 3
4 13 1732.72 28 14.85 2621 1090 2.61 / 541.62 2 4
5 13 768.00 28 14.96 1440 603 3.21 / 542.22 2 7
6 13 64.64 6 15.13 532 48 3.26 / 542.27 2 7
Average= 3.85
(KJ/cycle)

Cycle 139

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.16 15 15.10 649 147 0.15 / 536.03 2 3
2 7 2008.44 31 14.91 2938 1358 1.50 / 537.39 2 3
3 13 1595.16 28 14.87 2450 1020 2.53 / 538.41 2 5
4 13 663.08 28 14.99 1313 551 3.08 / 538.96 2 7
5 13 78.32 6 15.14 544 49 3.13 / 539.01 2 7
Average= 3.85
(KJ/cycle)

Cycle 138

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.20 25 15.08 655 247 0.25 / 532.87 2 6
2 3 590.20 -15 15.46 4 0 0.00 / 532.87 2 6
3 3 960.12 -1 15.48 4 0 0.00 / 532.87 2 6
4 7 2008.12 31 14.90 2945 1360 1.61 / 534.23 2 3
5 13 1598.12 28 14.87 2454 1022 2.63 / 535.25 2 4
6 13 782.24 28 14.97 1432 600 3.23 / 535.85 2 7
7 13 45.60 5 15.14 494 37 3.27 / 535.89 2 7
Average= 3.86
(KJ/cycle)

Cycle 137

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.84 24 14.99 663 239 0.24 / 529.59 2 4
2 10 1019.52 2 15.00 1811 54 0.29 / 529.64 2 3
3 3 985.48 -1 15.43 4 0 0.05 / 529.64 2 3
4 7 2003.88 31 14.93 2931 1357 1.65 / 531.00 2 2
5 13 1605.40 28 14.89 2448 1021 2.67 / 532.02 2 4
6 13 690.52 28 15.00 1335 561 3.23 / 532.58 2 6
7 13 58.84 5 15.15 513 39 3.27 / 532.62 2 7
Average= 3.86
(KJ/cycle)

Cycle 136

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.48 25 15.02 640 240 0.24 / 525.18 2 4
2 3 964.48 -1 15.45 4 0 0.00 / 525.18 2 4
3 7 2004.16 31 14.92 2924 1352 1.59 / 526.54 2 3
4 13 1610.64 28 14.88 2455 1023 2.62 / 527.56 2 4
5 13 684.40 28 15.00 1317 553 3.17 / 528.11 2 7
6 13 55.32 5 15.15 502 38 3.21 / 528.15 2 8
7 8 0.36 165 15.10 398 992 4.20 / 529.14 2 17
8 14 0.36 35 15.07 397 209 4.41 / 529.35 2 19
Average= 3.86
(KJ/cycle)

Cycle 135 GMT 11/ 8/2022 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.48 24 15.02 650 234 0.23 / 520.97 2 3
2 3 1032.12 1 15.12 1837 28 0.26 / 520.99 2 3
3 7 2003.64 31 14.93 2934 1358 1.62 / 522.35 2 3
4 13 1601.04 28 14.89 2446 1020 2.64 / 523.37 2 4
5 13 669.32 28 15.01 1288 541 3.18 / 523.91 2 6
6 13 80.32 6 15.14 525 48 3.23 / 523.96 2 7
7 8 0.36 165 15.10 395 984 4.21 / 524.94 2 17
Average= 3.86
(KJ/cycle)

Cycle 134 GMT 1/ 8/2022 5:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.64 24 15.01 639 230 0.23 / 516.77 2 4
2 7 2003.96 31 14.93 2933 1357 1.59 / 518.13 2 3
3 13 1448.72 28 14.91 2267 946 2.53 / 519.08 2 4
4 13 825.76 28 14.97 1487 623 3.16 / 519.70 2 6
5 13 70.52 6 15.15 518 47 3.20 / 519.75 2 7
6 8 0.16 165 15.10 395 984 4.19 / 520.73 2 17
Average= 3.86
(KJ/cycle)

Cycle 133 GMT 22/ 7/2022 7:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.00 25 15.02 634 238 0.24 / 512.34 2 4
2 3 961.28 -1 15.45 4 0 0.00 / 512.34 2 4
3 7 2006.60 32 14.91 2933 1399 1.64 / 513.74 2 3
4 13 1578.28 28 14.89 2410 1005 2.64 / 514.75 2 5
5 13 642.84 28 15.01 1254 527 3.17 / 515.27 2 6
6 13 55.08 5 15.15 506 38 3.21 / 515.31 2 8
7 8 -0.08 165 15.10 407 1014 4.22 / 516.33 2 17
8 14 -0.08 35 15.07 408 215 4.44 / 516.54 2 20
Average= 3.85
(KJ/cycle)

Cycle 132 GMT 12/ 7/2022 9:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.32 24 15.02 640 231 0.23 / 508.02 2 4
2 3 1039.48 1 15.11 1843 28 0.26 / 508.05 2 3
3 7 2003.60 31 14.91 2933 1356 1.61 / 509.40 2 3
4 13 1719.80 28 14.87 2590 1078 2.69 / 510.48 2 4
5 13 757.04 28 14.98 1404 589 3.28 / 511.07 2 6
6 13 61.08 6 15.16 500 45 3.33 / 511.11 2 8
7 8 0.32 165 15.10 398 992 4.32 / 512.11 2 17
Average= 3.85
(KJ/cycle)

Cycle 131 GMT 2/ 7/2022 11:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.32 24 15.03 654 236 0.24 / 503.81 2 4
2 7 2005.80 31 14.92 2929 1355 1.59 / 505.17 2 3
3 13 1598.00 28 14.88 2451 1021 2.61 / 506.19 2 5
4 13 778.12 28 14.98 1432 601 3.21 / 506.79 2 7
5 8 0.60 165 15.11 401 1000 4.21 / 507.79 2 14
Average= 3.85
(KJ/cycle)

Cycle 130 GMT 22/ 6/2022 14: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.08 24 15.02 642 231 0.23 / 499.68 2 4
2 7 2002.68 31 14.92 2925 1353 1.58 / 501.03 2 3
3 13 1585.88 28 14.89 2431 1014 2.60 / 502.05 2 4
4 13 655.04 28 15.01 1275 536 3.13 / 502.58 2 7
5 8 0.12 165 15.11 398 992 4.13 / 503.57 2 19
Average= 3.84
(KJ/cycle)

Cycle 129 GMT 12/ 6/2022 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.32 24 15.02 645 233 0.23 / 495.48 2 3
2 3 1037.44 1 15.12 1845 28 0.26 / 495.51 2 3
3 7 2003.92 31 14.92 2921 1351 1.61 / 496.86 2 3
4 13 1594.88 28 14.89 2442 1018 2.63 / 497.88 2 4
5 13 648.20 28 15.02 1272 535 3.16 / 498.41 2 7
6 13 51.72 5 15.16 503 38 3.20 / 498.45 2 7
7 8 0.00 165 15.11 401 1000 4.20 / 499.45 2 15
Average= 3.84
(KJ/cycle)

Cycle 128 GMT 2/ 6/2022 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.92 24 15.02 634 229 0.23 / 491.04 2 4
2 3 986.00 -1 15.45 4 0 0.00 / 491.04 2 4
3 3 1016.76 1 15.17 1811 27 0.26 / 491.07 2 3
4 7 2009.80 31 14.92 2939 1359 1.62 / 492.43 2 3
5 13 1615.28 28 14.89 2467 1029 2.64 / 493.46 2 5
6 13 669.76 28 15.01 1292 543 3.19 / 494.00 2 6
7 13 19.60 7 15.17 448 48 3.23 / 494.05 2 8
8 8 0.24 165 15.11 397 990 4.22 / 495.04 2 19
9 14 0.24 35 15.08 394 208 4.43 / 495.25 2 19
Average= 3.84
(KJ/cycle)

Cycle 127 GMT 23/ 5/2022 20: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.52 24 15.03 640 231 0.23 / 486.56 2 4
2 3 981.28 -1 15.45 4 0 0.00 / 486.56 2 4
3 7 2005.76 31 14.92 2933 1357 1.59 / 487.91 2 3
4 13 1742.40 28 14.87 2612 1088 2.67 / 489.00 2 4
5 13 638.72 28 15.02 1249 525 3.20 / 489.53 2 7
6 13 161.24 8 15.13 641 78 3.28 / 489.60 2 7
7 8 0.40 165 15.11 401 1000 4.28 / 490.60 2 15
8 14 0.40 35 15.08 398 210 4.49 / 490.81 2 18
Average= 3.83
(KJ/cycle)

Cycle 126 GMT 13/ 5/2022 22: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.08 24 15.04 626 226 0.23 / 482.18 2 4
2 7 2002.00 31 14.92 2939 1359 1.59 / 483.54 2 3
3 13 1598.48 28 14.89 2439 1017 2.60 / 484.56 2 4
4 13 674.16 28 15.01 1297 545 3.15 / 485.10 2 7
5 13 78.56 6 15.15 531 48 3.20 / 485.15 2 7
6 13 17.36 28 15.15 441 187 3.38 / 485.34 2 10
7 8 -0.04 165 15.10 396 987 4.37 / 486.33 2 22
Average= 3.83
(KJ/cycle)

Cycle 125 GMT 4/ 5/2022 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.48 25 15.03 639 240 0.24 / 477.90 2 4
2 3 976.16 -1 15.45 4 0 0.00 / 477.90 2 4
3 7 2009.60 32 14.92 2939 1403 1.64 / 479.30 2 3
4 13 1733.44 28 14.87 2606 1085 2.73 / 480.39 2 4
5 13 754.24 28 15.00 1393 585 3.31 / 480.97 2 7
6 8 0.04 165 15.12 395 985 4.30 / 481.96 2 23
Average= 3.83
(KJ/cycle)

Cycle 124 GMT 24/ 4/2022 2:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.60 24 15.04 636 230 0.23 / 473.71 2 4
2 3 1021.56 1 15.15 1825 28 0.26 / 473.73 2 3
3 7 2003.56 31 14.92 2924 1352 1.61 / 475.09 2 3
4 13 1591.68 28 14.89 2440 1017 2.63 / 476.10 2 4
5 13 656.80 28 15.02 1276 537 3.16 / 476.64 2 7
6 13 51.76 5 15.16 495 38 3.20 / 476.68 2 7
7 8 0.24 165 15.11 393 980 4.18 / 477.66 2 17
Average= 3.82
(KJ/cycle)

Cycle 123 GMT 14/ 4/2022 4:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.56 24 15.04 631 228 0.23 / 469.52 2 4
2 3 985.84 -1 15.49 4 0 0.00 / 469.52 2 4
3 7 2005.32 31 14.94 2934 1359 1.59 / 470.88 2 3
4 13 1600.04 28 14.90 2456 1025 2.61 / 471.90 2 5
5 13 700.64 28 15.01 1332 560 3.17 / 472.46 2 7
6 8 0.16 165 15.12 406 1013 4.18 / 473.48 2 17
Average= 3.82
(KJ/cycle)

Cycle 122 GMT 4/ 4/2022 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.44 25 15.03 631 237 0.24 / 465.31 2 4
2 3 980.28 -1 15.46 4 0 0.00 / 465.31 2 4
3 7 2002.24 31 14.93 2927 1355 1.59 / 466.67 2 3
4 13 1583.92 28 14.90 2436 1016 2.61 / 467.69 2 4
5 13 667.40 28 15.02 1289 542 3.15 / 468.23 2 7
6 13 90.20 6 15.15 564 51 3.20 / 468.28 2 7
7 8 -0.12 165 15.11 407 1015 4.22 / 469.29 2 16
Average= 3.82
(KJ/cycle)

Cycle 121 GMT 25/ 3/2022 8:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.80 24 15.05 633 229 0.23 / 460.82 2 3
2 10 1015.40 2 15.02 1825 55 0.28 / 460.87 2 3
3 3 971.00 -1 15.45 4 0 0.05 / 460.87 2 3
4 7 2003.60 31 14.93 2939 1360 1.64 / 462.24 2 4
5 13 1592.92 28 14.90 2432 1015 2.66 / 463.25 2 4
6 13 797.64 28 14.98 1464 614 3.27 / 463.86 2 7
7 8 0.68 165 15.12 402 1003 4.28 / 464.87 2 21
8 14 0.68 35 15.09 399 211 4.49 / 465.08 4 21
Average= 3.81
(KJ/cycle)

Cycle 120 GMT 15/ 3/2022 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.88 24 15.03 624 225 0.23 / 456.66 2 3
2 7 2006.24 31 14.93 2935 1358 1.58 / 458.02 2 3
3 13 1598.64 28 14.89 2455 1024 2.61 / 459.04 2 4
4 13 657.24 28 15.02 1281 539 3.15 / 459.58 2 6
5 8 0.36 165 15.12 404 1008 4.15 / 460.59 2 18
Average= 3.81
(KJ/cycle)

Cycle 119 GMT 5/ 3/2022 13:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.80 24 15.01 652 235 0.23 / 452.11 2 4
2 7 2003.68 31 14.94 2938 1361 1.60 / 453.47 2 3
3 13 1586.28 28 14.90 2451 1023 2.62 / 454.49 2 5
4 13 644.20 28 15.03 1261 531 3.15 / 455.02 2 7
5 13 64.16 28 15.15 499 212 3.36 / 455.23 2 9
6 8 -0.16 165 15.11 399 995 4.36 / 456.23 2 21
7 14 -0.16 35 15.08 396 209 4.56 / 456.44 2 23
Average= 3.80
(KJ/cycle)

Cycle 118 GMT 23/ 2/2022 15:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.96 25 15.03 652 245 0.24 / 447.47 2 4
2 3 972.92 -1 15.46 4 0 0.00 / 447.47 2 4
3 7 2004.40 31 14.93 2936 1359 1.60 / 448.82 2 3
4 13 1596.96 28 14.89 2465 1028 2.63 / 449.85 2 4
5 13 668.84 28 15.01 1321 555 3.19 / 450.41 2 7
6 13 34.16 28 15.15 477 202 3.39 / 450.61 2 9
7 8 0.12 165 15.10 421 1049 4.44 / 451.66 2 20
8 14 0.12 35 15.07 408 215 4.65 / 451.87 3 21
Average= 3.80
(KJ/cycle)

Cycle 117 GMT 13/ 2/2022 17:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.32 24 15.05 635 229 0.23 / 442.94 2 4
2 10 1003.16 2 15.04 1799 54 0.28 / 443.00 2 3
3 3 959.48 -1 15.45 4 0 0.05 / 443.00 2 3
4 7 2002.00 31 14.94 2930 1357 1.64 / 444.35 2 4
5 13 1589.96 28 14.91 2440 1019 2.66 / 445.37 2 4
6 13 794.88 28 15.00 1452 610 3.27 / 445.98 2 6
7 13 54.80 28 15.15 495 210 3.48 / 446.19 2 9
8 8 0.32 165 15.11 412 1027 4.51 / 447.22 2 17
Average= 3.79
(KJ/cycle)

Cycle 116 GMT 3/ 2/2022 19:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.12 25 15.06 636 239 0.24 / 438.73 2 4
2 3 976.24 -1 15.46 4 0 0.00 / 438.73 2 4
3 7 2003.60 32 14.93 2935 1402 1.64 / 440.13 2 3
4 13 1593.04 28 14.90 2440 1018 2.66 / 441.15 2 4
5 13 643.88 28 15.03 1257 529 3.19 / 441.68 2 7
6 13 51.40 5 15.17 498 38 3.23 / 441.72 2 7
7 8 -0.04 165 15.12 400 998 4.22 / 442.71 2 17
Average= 3.78
(KJ/cycle)

Cycle 115 GMT 24/ 1/2022 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.00 24 15.05 645 233 0.23 / 434.52 2 4
2 10 1019.64 3 15.04 1820 82 0.32 / 434.61 2 3
3 3 957.08 -2 15.46 4 0 0.08 / 434.61 2 3
4 7 2002.00 31 14.93 2923 1353 1.67 / 435.96 2 3
5 13 1572.80 28 14.91 2401 1002 2.67 / 436.96 2 5
6 13 635.60 28 15.03 1253 527 3.20 / 437.49 2 7
7 8 0.08 165 15.13 401 1001 4.20 / 438.49 2 16
Average= 3.78
(KJ/cycle)

Cycle 114 GMT 14/ 1/2022 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.60 24 15.04 654 236 0.24 / 430.33 2 4
2 7 2002.40 31 14.94 2934 1359 1.59 / 431.69 2 3
3 13 1600.48 28 14.91 2457 1026 2.62 / 432.71 2 4
4 13 649.28 28 15.03 1274 536 3.16 / 433.25 2 6
5 13 53.08 5 15.18 503 38 3.19 / 433.29 2 7
6 8 0.24 165 15.12 403 1005 4.20 / 434.29 2 15
Average= 3.78
(KJ/cycle)

Cycle 113 GMT 5/ 1/2022 1:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.12 24 15.05 638 230 0.23 / 426.02 2 4
2 3 1030.72 1 15.14 1829 28 0.26 / 426.05 2 4
3 7 2006.32 31 14.94 2929 1357 1.61 / 427.41 2 3
4 13 1600.84 28 14.90 2459 1026 2.64 / 428.43 2 4
5 13 792.80 28 15.00 1452 610 3.25 / 429.04 2 6
6 13 64.96 6 15.17 515 47 3.30 / 429.09 2 8
7 8 0.08 165 15.13 401 1001 4.30 / 430.09 2 16
Average= 3.77
(KJ/cycle)

Cycle 112 GMT 26/12/2021 4: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.64 23 15.06 643 223 0.22 / 421.77 2 4
2 3 1036.76 1 15.13 1868 28 0.25 / 421.80 2 3
3 7 2010.00 31 14.94 2938 1361 1.61 / 423.16 2 3
4 13 1589.96 28 14.91 2438 1018 2.63 / 424.18 2 4
5 13 790.36 28 15.00 1448 608 3.24 / 424.78 2 6
6 8 0.28 165 15.13 404 1009 4.25 / 425.79 2 18
Average= 3.77
(KJ/cycle)

Cycle 111 GMT 16/12/2021 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.44 24 15.03 644 232 0.23 / 417.62 2 5
2 3 945.32 -2 15.46 4 0 0.00 / 417.62 2 5
3 7 2006.72 31 14.94 2929 1357 1.59 / 418.98 2 3
4 13 1600.52 28 14.91 2449 1022 2.61 / 420.00 2 4
5 13 663.08 28 15.03 1286 541 3.15 / 420.54 2 7
6 8 0.20 165 15.13 401 1001 4.15 / 421.55 2 15
Average= 3.76
(KJ/cycle)

Cycle 110 GMT 6/12/2021 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.00 23 15.04 635 220 0.22 / 413.19 2 4
2 3 1029.60 1 15.14 1843 28 0.25 / 413.21 2 3
3 7 2002.80 31 14.95 2928 1357 1.60 / 414.57 2 3
4 13 1573.96 28 14.92 2418 1010 2.61 / 415.58 2 4
5 13 647.12 28 15.04 1271 535 3.15 / 416.12 2 8
6 13 50.88 5 15.18 499 38 3.19 / 416.15 2 7
7 8 0.24 165 15.13 410 1024 4.21 / 417.18 2 15
8 14 0.24 35 15.09 406 214 4.43 / 417.39 2 20
Average= 3.76
(KJ/cycle)

Cycle 109 GMT 26/11/2021 10:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.56 23 15.05 672 233 0.23 / 408.92 2 5
2 3 1029.32 1 15.14 1838 28 0.26 / 408.95 2 3
3 7 2007.40 31 14.94 2935 1359 1.62 / 410.31 2 3
4 13 1600.44 28 14.90 2470 1030 2.65 / 411.34 2 4
5 13 705.64 28 15.02 1343 565 3.22 / 411.91 2 6
6 13 52.40 5 15.18 507 38 3.25 / 411.94 2 7
7 8 -0.08 165 15.12 410 1023 4.28 / 412.97 2 17
Average= 3.75
(KJ/cycle)

Cycle 108 GMT 16/11/2021 12:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.20 24 15.05 647 234 0.23 / 404.63 2 5
2 3 977.24 -1 15.47 4 0 0.00 / 404.63 2 5
3 7 2003.16 31 14.95 2928 1357 1.59 / 405.99 2 3
4 13 1592.00 28 14.91 2466 1030 2.62 / 407.02 2 5
5 13 784.20 28 15.00 1467 616 3.24 / 407.64 2 7
6 8 0.36 165 15.13 422 1054 4.29 / 408.69 2 18
Average= 3.75
(KJ/cycle)

Cycle 107 GMT 6/11/2021 14:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.00 24 15.05 631 228 0.23 / 400.22 2 5
2 3 971.32 -1 15.47 5 0 0.00 / 400.22 2 5
3 7 2009.52 31 14.94 2942 1363 1.59 / 401.58 2 3
4 13 1442.96 28 14.94 2254 943 2.53 / 402.53 2 4
5 13 786.32 28 15.01 1445 607 3.14 / 403.13 2 7
6 13 60.00 5 15.18 513 39 3.18 / 403.17 2 8
7 8 0.12 165 15.13 406 1014 4.19 / 404.19 2 16
8 14 0.12 35 15.10 404 214 4.41 / 404.40 2 20
Average= 3.74
(KJ/cycle)

Cycle 106 GMT 27/10/2021 16:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.44 23 15.05 638 221 0.22 / 395.81 2 4
2 3 1053.32 2 15.12 1868 56 0.28 / 395.87 2 3
3 3 984.80 -1 15.50 4 0 0.06 / 395.87 2 3
4 7 2005.48 31 14.95 2938 1362 1.64 / 397.23 2 3
5 13 1601.48 28 14.92 2447 1022 2.66 / 398.25 2 5
6 13 666.08 28 15.04 1286 542 3.20 / 398.80 2 6
7 8 0.32 165 15.14 396 989 4.19 / 399.78 2 16
8 14 0.32 35 15.11 395 209 4.40 / 399.99 2 18
Average= 3.74
(KJ/cycle)

Cycle 105 GMT 17/10/2021 18:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.40 24 15.06 626 226 0.23 / 391.49 2 5
2 3 976.36 -1 15.47 4 0 0.00 / 391.49 2 5
3 7 2004.84 31 14.94 2935 1359 1.59 / 392.85 2 3
4 13 1580.40 28 14.91 2426 1013 2.60 / 393.86 2 4
5 13 651.00 28 15.04 1266 533 3.13 / 394.40 2 6
6 8 -0.28 165 15.14 395 987 4.12 / 395.38 2 19
7 14 -0.28 35 15.11 394 208 4.33 / 395.59 2 16
Average= 3.73
(KJ/cycle)

Cycle 104 GMT 7/10/2021 20:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.44 24 15.05 634 229 0.23 / 387.00 2 4
2 7 2005.96 31 14.94 2936 1360 1.59 / 388.36 2 3
3 13 1565.40 28 14.92 2407 1006 2.59 / 389.36 2 5
4 13 633.12 28 15.05 1244 524 3.12 / 389.89 2 7
5 13 17.04 28 15.18 427 181 3.30 / 390.07 2 9
6 8 0.12 165 15.13 396 989 4.29 / 391.06 2 20
7 14 0.12 35 15.10 397 210 4.50 / 391.27 3 23
Average= 3.73
(KJ/cycle)

Cycle 103 GMT 27/ 9/2021 22: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.20 23 15.06 631 219 0.22 / 382.67 2 5
2 7 2003.32 31 14.95 2929 1357 1.58 / 384.02 2 3
3 13 1460.24 28 14.94 2272 950 2.53 / 384.97 2 4
4 13 699.56 28 15.03 1326 558 3.08 / 385.53 2 7
5 13 53.96 5 15.19 489 37 3.12 / 385.57 2 8
6 8 0.96 165 15.14 396 989 4.11 / 386.56 2 12
7 14 0.96 35 15.11 394 208 4.32 / 386.77 2 22
Average= 3.72
(KJ/cycle)

Cycle 102 GMT 18/ 9/2021 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.28 24 15.05 653 236 0.24 / 378.22 2 5
2 3 970.20 -1 15.47 4 0 0.00 / 378.22 2 5
3 7 2006.24 31 14.95 2933 1359 1.60 / 379.58 2 3
4 13 1583.96 28 14.92 2431 1016 2.61 / 380.60 2 4
5 13 782.04 28 15.02 1438 605 3.22 / 381.20 2 7
6 13 60.76 6 15.19 500 46 3.26 / 381.25 2 7
7 8 0.00 165 15.14 398 994 4.26 / 382.24 2 20
8 14 0.00 35 15.11 395 209 4.46 / 382.45 2 21
Average= 3.71
(KJ/cycle)

Cycle 101 GMT 8/ 9/2021 2: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.12 23 15.06 637 221 0.22 / 373.78 2 5
2 3 1038.84 1 15.14 1866 28 0.25 / 373.81 2 3
3 7 2003.64 31 14.94 2932 1358 1.61 / 375.16 2 3
4 13 1594.92 28 14.91 2454 1024 2.63 / 376.19 2 4
5 13 682.28 28 15.03 1325 558 3.19 / 376.75 2 7
6 13 51.48 5 15.19 497 38 3.23 / 376.78 2 8
7 8 0.48 165 15.14 397 992 4.22 / 377.78 2 17
8 14 0.48 35 15.11 395 209 4.43 / 377.98 2 20
Average= 3.71
(KJ/cycle)

Cycle 100 GMT 29/ 8/2021 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.04 23 15.06 629 218 0.22 / 369.60 2 5
2 7 2002.64 31 14.96 2934 1361 1.58 / 370.96 2 3
3 13 1597.16 28 14.92 2464 1029 2.61 / 371.99 2 4
4 13 656.76 28 15.05 1277 538 3.15 / 372.53 2 6
5 13 43.68 5 15.20 479 36 3.18 / 372.57 2 7
6 8 -0.20 165 15.15 396 990 4.17 / 373.56 2 21
Average= 3.70
(KJ/cycle)

Cycle 99 GMT 19/ 8/2021 6: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.00 23 15.07 626 217 0.22 / 365.14 2 5
2 3 1028.84 1 15.15 1856 28 0.25 / 365.17 2 3
3 7 2002.80 31 14.95 2938 1362 1.61 / 366.53 2 3
4 13 1601.72 28 14.91 2458 1026 2.63 / 367.56 2 4
5 13 817.48 28 15.00 1486 624 3.26 / 368.18 2 8
6 8 0.08 165 15.15 397 992 4.25 / 369.17 2 17
7 14 0.08 35 15.12 397 210 4.46 / 369.38 2 19
Average= 3.69
(KJ/cycle)

Cycle 98 GMT 9/ 8/2021 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.76 23 15.04 647 224 0.22 / 360.90 2 5
2 3 971.44 -1 15.47 4 0 0.00 / 360.90 2 5
3 7 2005.28 32 14.95 2933 1403 1.63 / 362.30 2 3
4 13 1592.72 28 14.92 2431 1016 2.64 / 363.32 2 4
5 13 771.04 28 15.02 1426 600 3.24 / 363.92 2 7
6 8 0.12 165 15.15 404 1010 4.25 / 364.93 2 16
Average= 3.69
(KJ/cycle)

Cycle 97 GMT 30/ 7/2021 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.84 23 15.06 649 225 0.22 / 356.29 2 5
2 3 975.96 -1 15.51 4 0 0.00 / 356.29 2 5
3 7 2003.28 31 14.96 2938 1363 1.59 / 357.65 2 3
4 13 1459.44 28 14.94 2281 954 2.54 / 358.61 2 4
5 13 713.96 28 15.03 1362 573 3.11 / 359.18 2 7
6 13 53.12 5 15.19 510 39 3.15 / 359.22 2 7
7 13 17.20 28 15.18 451 192 3.35 / 359.41 2 8
8 8 0.44 165 15.12 419 1045 4.39 / 360.46 2 21
9 14 0.44 35 15.09 407 215 4.61 / 360.67 3 21
Average= 3.68
(KJ/cycle)

Cycle 96 GMT 20/ 7/2021 11:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.80 24 15.07 622 225 0.22 / 351.93 2 5
2 3 961.92 -1 15.48 4 0 0.00 / 351.93 2 5
3 7 2006.76 31 14.94 2934 1359 1.58 / 353.28 2 3
4 13 1459.12 28 14.93 2310 966 2.55 / 354.25 2 5
5 13 668.32 28 15.04 1309 551 3.10 / 354.80 2 6
6 13 77.80 6 15.19 538 49 3.15 / 354.85 2 7
7 8 -0.20 165 15.14 402 1004 4.15 / 355.86 2 29
8 14 -0.20 35 15.11 402 213 4.37 / 356.07 2 18
Average= 3.67
(KJ/cycle)

Cycle 95 GMT 10/ 7/2021 13:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.92 24 15.08 649 235 0.23 / 347.84 2 5
2 7 2008.68 31 14.95 2942 1363 1.60 / 349.21 2 3
3 13 1473.36 28 14.94 2295 960 2.56 / 350.17 2 5
4 13 590.12 28 15.06 1188 501 3.06 / 350.67 2 6
5 13 46.12 5 15.19 495 38 3.10 / 350.71 2 7
6 8 0.44 165 15.14 398 994 4.09 / 351.70 2 21
Average= 3.66
(KJ/cycle)

Cycle 94 GMT 30/ 6/2021 15:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.92 24 15.08 649 235 0.23 / 343.68 2 4
2 7 2004.84 31 14.96 2935 1361 1.60 / 345.04 2 4
3 13 1592.92 28 14.93 2440 1020 2.62 / 346.06 2 5
4 13 642.84 28 15.06 1255 529 3.15 / 346.59 2 6
5 13 44.36 5 15.21 479 36 3.18 / 346.62 2 7
6 8 -0.16 165 15.15 394 985 4.17 / 347.61 2 19
Average= 3.66
(KJ/cycle)

Cycle 93 GMT 20/ 6/2021 17:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.16 24 15.08 649 235 0.23 / 339.38 2 4
2 7 2003.44 31 14.95 2936 1361 1.60 / 340.74 2 3
3 13 1731.24 28 14.90 2607 1088 2.68 / 341.83 2 4
4 13 740.04 28 15.04 1381 582 3.26 / 342.41 2 7
5 13 19.52 5 15.21 450 34 3.30 / 342.45 2 8
6 8 0.24 165 15.15 399 997 4.30 / 343.44 2 20
Average= 3.65
(KJ/cycle)

Cycle 92 GMT 10/ 6/2021 19:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.32 24 15.06 633 229 0.23 / 335.10 2 4
2 3 1030.68 1 15.15 1833 28 0.26 / 335.12 2 3
3 7 2006.04 31 14.96 2938 1363 1.62 / 336.49 2 3
4 13 1611.92 28 14.92 2458 1027 2.65 / 337.51 2 4
5 13 858.96 28 15.00 1530 643 3.29 / 338.16 2 6
6 8 0.00 165 15.16 396 991 4.28 / 339.15 2 18
Average= 3.65
(KJ/cycle)

Cycle 91 GMT 31/ 5/2021 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.32 24 15.09 629 228 0.23 / 330.77 2 4
2 7 2002.68 31 14.95 2931 1358 1.59 / 332.13 2 4
3 13 1586.52 28 14.93 2430 1016 2.60 / 333.15 2 4
4 13 643.76 28 15.06 1263 533 3.13 / 333.68 2 8
5 8 0.00 165 15.16 391 978 4.11 / 334.66 2 15
6 14 0.00 35 15.13 393 208 4.32 / 334.87 2 21
Average= 3.64
(KJ/cycle)

Cycle 90 GMT 21/ 5/2021 23:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.20 24 15.08 638 231 0.23 / 326.59 2 4
2 3 976.72 -1 15.48 5 0 0.00 / 326.59 2 4
3 7 2005.40 32 14.95 2932 1403 1.63 / 328.00 2 3
4 13 1588.28 28 14.93 2434 1018 2.65 / 329.01 2 4
5 13 655.44 28 15.06 1287 543 3.19 / 329.56 2 8
6 8 0.64 165 15.16 396 991 4.18 / 330.55 2 16
Average= 3.63
(KJ/cycle)

Cycle 89 GMT 12/ 5/2021 1:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.12 24 15.09 626 227 0.23 / 322.33 2 4
2 3 1018.52 1 15.20 1803 27 0.25 / 322.36 2 3
3 7 2007.20 31 14.95 2945 1365 1.62 / 323.72 2 3
4 13 1592.08 28 14.92 2446 1022 2.64 / 324.75 2 5
5 13 665.64 28 15.06 1296 546 3.19 / 325.29 2 8
6 13 53.80 5 15.21 498 38 3.23 / 325.33 2 8
7 13 47.08 5 15.20 488 37 3.26 / 325.37 2 7
8 8 0.08 165 15.16 398 996 4.26 / 326.36 2 17
Average= 3.63
(KJ/cycle)

Cycle 88 GMT 2/ 5/2021 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.16 24 15.08 631 228 0.23 / 318.20 2 4
2 7 2002.72 32 14.95 2936 1405 1.63 / 319.61 2 3
3 13 1464.12 28 14.95 2283 956 2.59 / 320.56 2 5
4 13 676.40 28 15.05 1305 550 3.14 / 321.11 2 6
5 8 0.28 165 15.16 396 991 4.13 / 322.10 2 16
Average= 3.62
(KJ/cycle)

Cycle 87 GMT 22/ 4/2021 5:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.16 24 15.10 626 227 0.23 / 313.87 2 4
2 10 1011.28 2 15.07 1810 55 0.28 / 313.93 2 4
3 3 959.20 -1 15.48 4 0 0.05 / 313.93 2 4
4 3 983.80 -1 15.52 5 0 0.05 / 313.93 2 4
5 7 2005.68 31 14.96 2938 1363 1.64 / 315.29 2 4
6 13 1582.28 28 14.94 2421 1013 2.66 / 316.30 2 4
7 13 530.84 28 15.09 1118 472 3.13 / 316.77 2 6
8 8 -0.08 165 15.17 396 991 4.12 / 317.77 2 12
9 14 -0.08 35 15.14 396 210 4.33 / 317.98 2 19
Average= 3.61
(KJ/cycle)

Cycle 86 GMT 12/ 4/2021 7: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.36 24 15.10 631 229 0.23 / 309.76 2 4
2 3 980.32 -1 15.49 4 0 0.00 / 309.76 2 4
3 7 2003.84 31 14.95 2935 1360 1.59 / 311.12 2 4
4 13 1585.80 28 14.93 2427 1015 2.60 / 312.13 2 4
5 13 638.24 28 15.07 1248 527 3.13 / 312.66 2 6
6 8 0.12 165 15.17 394 986 4.12 / 313.65 2 16
Average= 3.61
(KJ/cycle)

Cycle 85 GMT 2/ 4/2021 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.12 24 15.10 625 226 0.23 / 305.64 2 4
2 7 2003.88 31 14.96 2927 1357 1.58 / 306.99 2 3
3 13 1596.24 28 14.93 2442 1021 2.60 / 308.01 2 5
4 13 643.80 28 15.07 1255 530 3.13 / 308.54 2 6
5 8 0.44 165 15.17 394 986 4.12 / 309.53 2 17
Average= 3.60
(KJ/cycle)

Cycle 84 GMT 23/ 3/2021 11: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.60 25 15.10 621 234 0.23 / 301.34 2 4
2 3 979.96 -1 15.49 4 0 0.00 / 301.34 2 4
3 7 2009.44 31 14.96 2940 1363 1.60 / 302.71 2 3
4 13 1468.28 28 14.95 2295 961 2.56 / 303.67 2 4
5 13 672.96 28 15.06 1292 545 3.10 / 304.21 2 6
6 8 -0.08 165 15.17 394 986 4.09 / 305.20 2 17
7 14 -0.08 35 15.14 397 210 4.30 / 305.41 3 22
Average= 3.59
(KJ/cycle)

Cycle 83 GMT 13/ 3/2021 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.28 24 15.11 611 222 0.22 / 297.04 2 4
2 10 1038.44 3 15.06 1835 83 0.30 / 297.13 2 4
3 3 956.32 -2 15.49 4 0 0.08 / 297.13 2 4
4 7 2006.56 31 14.97 2939 1364 1.67 / 298.49 2 3
5 13 1588.68 28 14.94 2435 1019 2.69 / 299.51 2 5
6 13 770.56 28 15.05 1413 595 3.28 / 300.11 2 6
7 8 0.20 165 15.17 401 1004 4.29 / 301.11 2 21
Average= 3.58
(KJ/cycle)

Cycle 82 GMT 3/ 3/2021 15:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.68 24 15.09 624 226 0.23 / 292.87 2 4
2 7 2012.08 23 15.07 2961 1026 1.25 / 293.89 2 2
3 13 1897.64 22 14.95 2816 926 2.18 / 294.82 2 4
4 13 1287.20 22 14.98 2066 681 2.86 / 295.50 2 5
5 13 458.16 22 15.12 1021 340 3.20 / 295.84 2 7
6 8 0.40 165 15.18 392 982 4.18 / 296.82 2 19
Average= 3.58
(KJ/cycle)

Cycle 81 GMT 21/ 2/2021 17:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.92 24 15.09 639 231 0.23 / 288.68 2 4
2 3 1016.28 1 15.19 1825 28 0.26 / 288.71 2 4
3 7 2003.32 30 14.98 2927 1315 1.57 / 290.03 2 3
4 13 1605.12 19 14.97 2463 701 2.28 / 290.73 2 3
5 13 1038.64 19 15.02 1763 503 2.78 / 291.23 2 5
6 13 455.60 19 15.12 1020 293 3.07 / 291.52 2 7
7 13 64.04 19 15.20 500 144 3.22 / 291.67 2 8
8 8 -0.28 165 15.17 389 974 4.19 / 292.64 2 17
Average= 3.57
(KJ/cycle)

Cycle 80 GMT 11/ 2/2021 19: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.20 24 15.10 629 228 0.23 / 284.56 2 4
2 7 2005.72 29 14.99 2942 1279 1.51 / 285.84 2 3
3 13 1606.16 19 14.97 2462 700 2.21 / 286.54 2 4
4 13 1027.80 19 15.03 1757 502 2.71 / 287.04 2 5
5 13 437.84 19 15.13 1001 288 3.00 / 287.33 2 6
6 13 12.56 19 15.22 435 126 3.12 / 287.45 2 9
7 8 0.08 165 15.17 399 999 4.12 / 288.45 2 19
Average= 3.56
(KJ/cycle)

Cycle 79 GMT 1/ 2/2021 20:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.04 23 15.09 646 224 0.22 / 280.52 2 4
2 3 1022.00 1 15.19 1851 28 0.25 / 280.54 2 4
3 7 2002.24 29 14.98 2932 1274 1.53 / 281.82 2 3
4 13 1607.76 19 14.97 2474 704 2.23 / 282.52 2 4
5 13 1018.32 19 15.03 1744 498 2.73 / 283.02 2 5
6 13 411.32 19 15.14 960 276 3.00 / 283.30 2 6
7 13 59.92 5 15.22 511 39 3.04 / 283.34 2 8
8 8 0.04 165 15.17 398 996 4.04 / 284.33 2 16
Average= 3.55
(KJ/cycle)

Cycle 78 GMT 22/ 1/2021 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.40 23 15.09 622 216 0.22 / 276.60 2 4
2 3 983.84 -1 15.49 4 0 0.00 / 276.60 2 4
3 7 2002.00 29 14.98 2936 1275 1.49 / 277.88 2 3
4 13 1611.24 19 14.97 2479 705 2.20 / 278.58 2 4
5 13 905.16 19 15.05 1602 458 2.65 / 279.04 2 7
6 13 345.36 14 15.16 882 187 2.84 / 279.23 2 6
7 13 57.28 5 15.22 514 39 2.88 / 279.27 2 7
8 8 0.52 165 15.17 409 1024 3.90 / 280.29 2 18
Average= 3.55
(KJ/cycle)

Cycle 77 GMT 13/ 1/2021 0:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.88 23 15.10 631 219 0.22 / 272.38 2 4
2 7 2003.48 29 15.00 2940 1279 1.50 / 273.66 2 3
3 13 1746.12 19 14.96 2634 749 2.25 / 274.41 2 4
4 13 1004.40 19 15.04 1722 492 2.74 / 274.90 2 5
5 13 421.96 19 15.14 976 281 3.02 / 275.18 2 7
6 8 0.04 165 15.18 397 994 4.01 / 276.18 2 14
7 14 0.04 35 15.15 398 211 4.22 / 276.39 2 22
Average= 3.54
(KJ/cycle)

Cycle 76 GMT 3/ 1/2021 1:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.44 24 15.10 628 228 0.23 / 268.46 2 4
2 3 978.72 -1 15.50 4 0 0.00 / 268.46 2 4
3 7 2004.00 29 14.98 2938 1276 1.50 / 269.74 2 3
4 13 1731.00 19 14.96 2624 746 2.25 / 270.48 2 4
5 13 979.16 19 15.04 1688 482 2.73 / 270.97 2 5
6 13 283.04 12 15.18 807 147 2.88 / 271.11 2 6
7 13 86.56 6 15.22 540 49 2.93 / 271.16 2 8
8 8 0.04 165 15.18 399 999 3.93 / 272.16 2 18
Average= 3.53
(KJ/cycle)

Cycle 75 GMT 24/12/2020 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.60 23 15.10 644 224 0.22 / 264.49 2 5
2 3 1036.56 1 15.18 1850 28 0.25 / 264.52 2 4
3 7 2004.36 29 14.99 2933 1275 1.53 / 265.79 2 3
4 13 1616.40 19 14.97 2475 704 2.23 / 266.50 2 4
5 13 931.12 19 15.05 1630 466 2.70 / 266.96 2 5
6 13 361.08 14 15.16 901 191 2.89 / 267.16 2 6
7 13 63.04 6 15.23 505 46 2.93 / 267.20 2 7
8 13 43.56 5 15.23 484 37 2.97 / 267.24 2 7
9 8 0.44 165 15.18 398 997 3.97 / 268.23 2 18
Average= 3.53
(KJ/cycle)

Cycle 74 GMT 14/12/2020 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.52 23 15.12 640 223 0.22 / 260.51 2 5
2 7 2008.32 29 14.99 2942 1279 1.50 / 261.79 2 3
3 13 1596.12 19 14.98 2454 698 2.20 / 262.49 2 5
4 13 1012.24 19 15.04 1735 496 2.70 / 262.99 2 5
5 13 401.56 19 15.15 954 275 2.97 / 263.26 2 7
6 8 0.04 165 15.18 401 1004 3.97 / 264.27 2 16
Average= 3.52
(KJ/cycle)

Cycle 73 GMT 4/12/2020 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.24 24 15.09 651 236 0.24 / 256.52 2 5
2 3 971.12 -1 15.50 4 0 0.00 / 256.52 2 5
3 7 2002.36 30 15.00 2932 1319 1.56 / 257.84 2 3
4 13 1595.68 19 14.99 2453 699 2.25 / 258.54 2 4
5 13 890.80 19 15.07 1581 453 2.71 / 258.99 2 6
6 13 457.72 19 15.14 1031 297 3.00 / 259.29 2 6
7 8 -0.12 165 15.18 401 1004 4.01 / 260.29 2 17
Average= 3.52
(KJ/cycle)

Cycle 72 GMT 24/11/2020 8:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.12 23 15.10 655 227 0.23 / 252.54 2 5
2 3 1032.32 1 15.18 1844 28 0.26 / 252.57 2 4
3 7 2004.36 29 14.99 2938 1277 1.53 / 253.85 2 3
4 13 1585.88 19 14.99 2438 694 2.23 / 254.54 2 5
5 13 1017.56 19 15.04 1739 497 2.72 / 255.04 2 5
6 13 318.72 13 15.18 848 167 2.89 / 255.21 2 6
7 13 96.92 7 15.23 566 60 2.95 / 255.27 2 7
8 8 0.44 165 15.18 406 1017 3.97 / 256.28 2 19
Average= 3.51
(KJ/cycle)

Cycle 71 GMT 14/11/2020 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.84 23 15.11 654 227 0.23 / 248.49 2 5
2 7 2008.00 29 15.01 2942 1281 1.51 / 249.77 2 3
3 13 1740.60 19 14.98 2627 748 2.26 / 250.52 2 4
4 13 1004.24 19 15.05 1736 496 2.75 / 251.01 2 5
5 13 406.16 19 15.15 972 280 3.03 / 251.29 2 7
6 8 0.88 165 15.19 408 1023 4.05 / 252.32 2 15
Average= 3.50
(KJ/cycle)

Cycle 70 GMT 4/11/2020 11:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.04 23 15.11 650 226 0.23 / 244.28 2 5
2 7 2001.60 29 15.00 2939 1278 1.50 / 245.56 2 4
3 13 1598.44 19 14.99 2458 700 2.20 / 246.26 2 4
4 13 1007.16 19 15.05 1721 492 2.70 / 246.75 2 5
5 13 411.52 19 15.15 964 277 2.97 / 247.03 2 7
6 8 0.20 165 15.19 407 1020 3.99 / 248.05 2 18
7 14 0.20 35 15.16 408 216 4.21 / 248.26 2 19
Average= 3.50
(KJ/cycle)

Cycle 69 GMT 25/10/2020 13:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.24 23 15.11 646 225 0.22 / 240.23 2 5
2 7 2003.24 29 15.00 2933 1276 1.50 / 241.50 2 3
3 13 1489.20 18 15.01 2336 631 2.13 / 242.13 2 5
4 13 1073.16 18 15.04 1810 490 2.62 / 242.62 2 5
5 13 466.16 18 15.14 1054 287 2.91 / 242.91 2 6
6 13 18.12 18 15.24 454 125 3.03 / 243.03 2 10
7 8 0.32 165 15.18 406 1017 4.05 / 244.05 2 17
Average= 3.49
(KJ/cycle)

Cycle 68 GMT 15/10/2020 14:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.80 23 15.13 641 223 0.22 / 236.25 2 5
2 7 2007.16 29 15.01 2933 1277 1.50 / 237.53 2 4
3 13 1605.40 18 15.00 2468 666 2.17 / 238.19 2 4
4 13 1039.36 18 15.05 1767 479 2.64 / 238.67 2 6
5 13 475.36 18 15.15 1053 287 2.93 / 238.96 2 6
6 13 46.24 5 15.24 502 38 2.97 / 239.00 2 7
7 8 0.44 165 15.19 400 1003 3.97 / 240.00 2 17
Average= 3.48
(KJ/cycle)

Cycle 67 GMT 5/10/2020 16:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.36 23 15.12 619 215 0.22 / 232.26 2 5
2 7 2007.32 29 15.02 2941 1281 1.50 / 233.55 2 3
3 13 1604.40 17 15.01 2470 630 2.13 / 234.18 2 3
4 13 1172.28 17 15.04 1925 492 2.62 / 234.67 2 5
5 13 560.76 17 15.14 1160 299 2.92 / 234.97 2 5
6 13 124.76 7 15.24 596 64 2.98 / 235.03 2 7
7 8 -0.16 165 15.20 398 998 3.98 / 236.03 2 22
Average= 3.47
(KJ/cycle)

Cycle 66 GMT 25/ 9/2020 18: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.48 23 15.13 645 224 0.22 / 227.98 2 5
2 7 2004.80 30 15.01 2931 1320 1.54 / 229.30 2 4
3 13 1590.76 17 15.01 2448 625 2.17 / 229.93 2 4
4 13 1154.56 17 15.04 1905 487 2.66 / 230.41 2 5
5 13 553.04 17 15.14 1142 294 2.95 / 230.71 2 6
6 13 66.96 6 15.25 516 47 3.00 / 230.75 2 7
7 13 18.88 12 15.25 445 81 3.08 / 230.84 2 8
8 8 0.16 165 15.20 400 1003 4.08 / 231.84 2 20
9 14 0.16 35 15.17 396 210 4.29 / 232.05 2 20
Average= 3.46
(KJ/cycle)

Cycle 65 GMT 15/ 9/2020 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.24 24 15.13 640 232 0.23 / 224.08 2 5
2 3 984.00 -1 15.52 4 0 0.00 / 224.08 2 5
3 7 2008.24 29 15.01 2943 1281 1.51 / 225.37 2 3
4 13 1605.36 17 15.01 2465 629 2.14 / 225.99 2 4
5 13 1044.20 17 15.07 1771 454 2.60 / 226.45 2 6
6 13 471.16 17 15.16 1040 268 2.86 / 226.72 2 6
7 13 91.84 6 15.25 540 49 2.91 / 226.77 2 7
8 8 0.08 165 15.21 395 991 3.90 / 227.76 2 19
Average= 3.45
(KJ/cycle)

Cycle 64 GMT 5/ 9/2020 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.12 23 15.14 642 224 0.22 / 220.14 2 5
2 3 1030.12 1 15.21 1839 28 0.25 / 220.17 2 4
3 7 2004.04 30 15.02 2934 1322 1.57 / 221.49 2 3
4 13 1471.32 17 15.02 2300 587 2.16 / 222.08 2 4
5 13 1057.84 17 15.06 1783 456 2.62 / 222.54 2 6
6 13 483.80 17 15.16 1055 272 2.89 / 222.81 2 6
7 13 59.44 5 15.25 512 39 2.93 / 222.85 2 7
8 8 0.36 165 15.21 400 1004 3.93 / 223.85 2 17
Average= 3.44
(KJ/cycle)

Cycle 63 GMT 26/ 8/2020 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.64 23 15.13 632 220 0.22 / 216.24 2 5
2 7 2005.72 29 15.01 2942 1281 1.50 / 217.52 2 3
3 13 1581.44 17 15.01 2435 621 2.12 / 218.14 2 4
4 13 1011.28 17 15.08 1722 441 2.56 / 218.58 2 5
5 13 566.68 17 15.15 1166 300 2.86 / 218.88 2 7
6 13 66.32 6 15.26 513 47 2.91 / 218.93 2 7
7 8 -0.08 165 15.21 396 994 3.90 / 219.92 2 17
Average= 3.44
(KJ/cycle)

Cycle 62 GMT 17/ 8/2020 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.28 23 15.14 632 220 0.22 / 212.21 2 5
2 10 1005.76 2 15.11 1802 54 0.27 / 212.27 2 4
3 3 958.12 -2 15.51 4 0 0.05 / 212.27 2 4
4 7 2005.08 30 15.02 2932 1321 1.60 / 213.59 2 3
5 13 1599.88 17 15.01 2459 627 2.22 / 214.21 2 4
6 13 1042.24 17 15.07 1763 452 2.67 / 214.67 2 6
7 13 602.20 17 15.14 1205 310 2.98 / 214.98 2 6
8 13 80.40 6 15.26 523 48 3.03 / 215.02 2 7
9 8 0.32 165 15.21 395 991 4.02 / 216.02 2 16
Average= 3.43
(KJ/cycle)

Cycle 61 GMT 7/ 8/2020 2:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.28 23 15.15 624 217 0.22 / 208.07 2 5
2 7 2007.48 30 15.02 2941 1325 1.54 / 209.39 2 3
3 13 1598.36 17 15.02 2460 628 2.17 / 210.02 2 5
4 13 1025.60 17 15.08 1744 447 2.62 / 210.47 2 5
5 13 485.00 17 15.17 1056 272 2.89 / 210.74 2 6
6 13 99.00 7 15.25 548 58 2.95 / 210.80 2 7
7 8 0.08 165 15.22 393 987 3.94 / 211.78 2 14
8 14 0.08 35 15.19 392 208 4.14 / 211.99 2 23
Average= 3.42
(KJ/cycle)

Cycle 60 GMT 28/ 7/2020 3:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.52 23 15.13 627 218 0.22 / 204.05 2 5
2 7 2003.96 30 15.02 2928 1319 1.54 / 205.37 2 3
3 13 1600.60 17 15.02 2459 628 2.17 / 205.99 2 4
4 13 1050.16 17 15.08 1778 456 2.62 / 206.45 2 5
5 13 471.20 17 15.17 1038 268 2.89 / 206.72 2 7
6 13 55.92 5 15.27 504 38 2.93 / 206.76 2 7
7 13 17.36 17 15.26 433 112 3.04 / 206.87 2 8
8 8 0.04 165 15.21 390 979 4.02 / 207.85 2 20
Average= 3.41
(KJ/cycle)

Cycle 59 GMT 18/ 7/2020 5:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.72 23 15.14 639 223 0.22 / 199.96 2 5
2 7 2006.84 29 15.03 2939 1281 1.50 / 201.24 2 4
3 13 1602.20 17 15.02 2469 630 2.13 / 201.87 2 3
4 13 1035.32 17 15.08 1754 450 2.58 / 202.32 2 6
5 13 481.88 17 15.17 1052 271 2.85 / 202.59 2 7
6 13 100.96 7 15.26 554 59 2.91 / 202.65 2 6
7 8 0.08 165 15.22 389 977 3.89 / 203.62 2 15
8 14 0.08 35 15.19 386 205 4.10 / 203.83 2 17
Average= 3.40
(KJ/cycle)

Cycle 58 GMT 8/ 7/2020 6:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.28 23 15.15 632 220 0.22 / 195.77 2 5
2 7 2003.04 29 15.03 2928 1276 1.50 / 197.05 2 3
3 13 1581.16 17 15.03 2437 623 2.12 / 197.67 2 5
4 13 1153.44 17 15.06 1897 486 2.60 / 198.16 2 5
5 13 552.52 17 15.16 1147 296 2.90 / 198.45 2 6
6 13 65.92 6 15.27 502 46 2.95 / 198.50 2 7
7 13 43.52 5 15.27 485 37 2.98 / 198.54 2 7
8 8 0.08 165 15.22 393 987 3.97 / 199.52 2 20
9 14 0.08 35 15.19 394 209 4.18 / 199.73 2 21
Average= 3.39
(KJ/cycle)

Cycle 57 GMT 28/ 6/2020 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.12 23 15.15 634 221 0.22 / 191.61 2 4
2 7 2002.60 30 15.03 2930 1321 1.54 / 192.94 2 4
3 13 1585.24 17 15.03 2446 625 2.17 / 193.56 2 4
4 13 1155.68 17 15.06 1909 489 2.66 / 194.05 2 5
5 13 553.68 17 15.17 1148 296 2.95 / 194.35 2 6
6 13 114.56 7 15.26 569 61 3.01 / 194.41 2 7
7 13 77.80 6 15.27 529 48 3.06 / 194.45 2 7
8 13 58.76 5 15.27 499 38 3.10 / 194.49 2 7
9 13 48.64 5 15.27 492 38 3.14 / 194.53 2 7
10 13 19.64 6 15.27 448 41 3.18 / 194.57 2 8
11 8 0.44 165 15.22 391 982 4.16 / 195.55 2 14
Average= 3.37
(KJ/cycle)

Cycle 56 GMT 18/ 6/2020 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.68 23 15.15 647 225 0.23 / 187.47 2 5
2 3 1018.12 1 15.23 1827 28 0.25 / 187.50 2 3
3 7 2008.48 29 15.04 2933 1279 1.53 / 188.78 2 4
4 13 1745.16 17 15.01 2640 674 2.21 / 189.46 2 4
5 13 1157.44 17 15.07 1909 489 2.70 / 189.94 2 5
6 13 570.20 17 15.16 1168 301 3.00 / 190.25 2 6
7 13 130.68 8 15.26 593 72 3.07 / 190.32 2 7
8 13 78.04 6 15.26 526 48 3.12 / 190.37 2 7
9 13 44.84 5 15.28 491 38 3.15 / 190.40 2 7
10 8 0.36 165 15.22 394 989 4.14 / 191.39 2 21
Average= 3.36
(KJ/cycle)

Cycle 55 GMT 8/ 6/2020 11:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.88 23 15.15 650 226 0.23 / 183.37 2 5
2 3 984.88 -1 15.53 4 0 0.00 / 183.37 2 5
3 7 2002.96 30 15.02 2932 1321 1.55 / 184.69 2 4
4 13 1602.24 17 15.03 2469 631 2.18 / 185.32 2 4
5 13 1045.88 17 15.08 1792 459 2.64 / 185.78 2 5
6 13 481.72 17 15.18 1066 275 2.91 / 186.05 2 6
7 13 94.72 7 15.27 561 60 2.97 / 186.11 2 7
8 13 43.04 5 15.27 488 37 3.01 / 186.15 2 8
9 13 17.92 17 15.27 443 115 3.13 / 186.27 2 9
10 8 -0.08 165 15.22 392 984 4.11 / 187.25 2 22
Average= 3.34
(KJ/cycle)

Cycle 54 GMT 29/ 5/2020 12:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.76 23 15.16 650 227 0.23 / 179.31 2 5
2 7 2003.96 29 15.02 2939 1280 1.51 / 180.59 2 3
3 13 1591.84 17 15.03 2457 628 2.13 / 181.22 2 5
4 13 988.88 17 15.11 1703 437 2.57 / 181.66 2 5
5 13 424.32 17 15.20 983 254 2.83 / 181.91 2 6
6 8 0.28 165 15.24 403 1013 3.84 / 182.93 2 16
7 14 0.28 35 15.21 403 215 4.05 / 183.14 2 20
Average= 3.33
(KJ/cycle)

Cycle 53 GMT 19/ 5/2020 14:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.84 23 15.16 633 221 0.22 / 175.41 2 5
2 7 2001.80 29 15.02 2934 1278 1.50 / 176.69 2 4
3 13 1576.48 17 15.03 2439 623 2.12 / 177.31 2 3
4 13 1160.04 17 15.07 1926 493 2.62 / 177.80 2 5
5 13 428.76 17 15.20 988 255 2.87 / 178.06 2 7
6 13 74.68 6 15.28 526 48 2.92 / 178.11 2 7
7 8 0.00 165 15.24 390 981 3.90 / 179.09 2 19
Average= 3.32
(KJ/cycle)

Cycle 52 GMT 9/ 5/2020 16:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.20 23 15.17 639 223 0.22 / 171.48 2 5
2 7 2003.28 30 15.03 2944 1327 1.55 / 172.81 2 3
3 13 1593.48 17 15.02 2460 628 2.18 / 173.44 2 4
4 13 896.96 17 15.12 1588 408 2.59 / 173.84 2 5
5 13 487.16 17 15.19 1060 274 2.86 / 174.12 2 7
6 13 88.00 6 15.28 535 49 2.91 / 174.17 2 7
7 13 58.76 5 15.28 503 38 2.95 / 174.21 2 7
8 8 0.48 165 15.24 390 981 3.93 / 175.19 2 16
Average= 3.31
(KJ/cycle)

Cycle 51 GMT 29/ 4/2020 17:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.00 23 15.17 639 223 0.22 / 167.53 2 5
2 7 2003.40 30 15.02 2925 1318 1.54 / 168.85 2 3
3 13 1724.48 17 15.01 2627 670 2.21 / 169.52 2 5
4 13 1018.52 17 15.10 1745 448 2.66 / 169.96 2 5
5 13 448.44 17 15.20 1011 261 2.92 / 170.23 2 7
6 13 80.40 6 15.28 532 49 2.97 / 170.27 2 7
7 8 -0.20 165 15.24 391 983 3.95 / 171.26 2 15
Average= 3.29
(KJ/cycle)

Cycle 50 GMT 19/ 4/2020 19: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.56 23 15.17 621 217 0.22 / 163.57 2 5
2 7 2003.00 30 15.02 2941 1325 1.54 / 164.90 2 4
3 13 1584.00 17 15.03 2449 626 2.17 / 165.52 2 4
4 13 1152.24 17 15.07 1913 490 2.66 / 166.01 2 6
5 13 424.92 17 15.21 981 254 2.91 / 166.27 2 6
6 13 74.00 6 15.29 526 48 2.96 / 166.31 2 7
7 8 0.60 165 15.24 394 991 3.95 / 167.31 2 18
Average= 3.28
(KJ/cycle)

Cycle 49 GMT 9/ 4/2020 20:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.40 22 15.17 643 215 0.21 / 159.56 2 5
2 10 1027.76 3 15.12 1827 83 0.30 / 159.65 2 4
3 3 950.56 -2 15.53 4 0 0.08 / 159.65 2 4
4 7 2003.12 29 15.03 2944 1283 1.58 / 160.93 2 5
5 13 1736.64 17 15.00 2634 672 2.25 / 161.60 2 4
6 13 1028.92 17 15.10 1760 452 2.70 / 162.05 2 6
7 13 443.08 17 15.20 1008 260 2.96 / 162.31 2 7
8 13 79.20 6 15.29 530 49 3.01 / 162.36 2 7
9 8 -0.36 165 15.25 394 991 4.00 / 163.35 2 18
Average= 3.27
(KJ/cycle)

Cycle 48 GMT 30/ 3/2020 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.64 23 15.14 633 220 0.22 / 155.63 2 5
2 3 956.32 -2 15.53 4 0 0.00 / 155.63 2 5
3 3 1016.68 1 15.26 1832 28 0.25 / 155.66 2 3
4 7 2009.76 29 15.03 2957 1289 1.54 / 156.95 2 4
5 13 1596.72 17 15.03 2469 631 2.17 / 157.58 2 4
6 13 907.44 17 15.12 1614 415 2.58 / 157.99 2 6
7 13 487.52 17 15.19 1066 275 2.86 / 158.27 2 6
8 13 87.08 6 15.29 537 49 2.91 / 158.32 2 7
9 13 59.20 5 15.29 509 39 2.95 / 158.35 2 8
10 8 0.24 165 15.24 396 996 3.94 / 159.35 2 15
Average= 3.25
(KJ/cycle)

Cycle 47 GMT 20/ 3/2020 23:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.72 23 15.14 643 224 0.22 / 151.50 2 5
2 7 2004.56 29 15.02 2951 1285 1.51 / 152.79 2 4
3 13 1583.92 17 15.04 2451 627 2.14 / 153.42 2 4
4 13 1023.44 17 15.10 1764 453 2.59 / 153.87 2 5
5 13 444.52 17 15.20 1016 263 2.85 / 154.13 2 6
6 13 55.20 5 15.30 502 38 2.89 / 154.17 2 7
7 13 46.52 5 15.29 492 38 2.93 / 154.21 2 8
8 8 0.48 165 15.25 396 996 3.92 / 155.20 2 14
9 14 0.48 35 15.22 385 205 4.13 / 155.41 2 17
Average= 3.24
(KJ/cycle)

Cycle 46 GMT 11/ 3/2020 0:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.04 24 15.15 626 228 0.23 / 147.55 2 4
2 7 2003.00 30 15.03 2943 1327 1.55 / 148.88 2 3
3 13 1603.04 17 15.03 2475 632 2.19 / 149.51 2 5
4 13 1040.36 17 15.10 1779 457 2.64 / 149.97 2 5
5 13 447.28 17 15.21 1012 262 2.91 / 150.23 2 6
6 13 75.20 6 15.29 528 48 2.95 / 150.28 2 7
7 8 0.40 165 15.25 397 999 3.95 / 151.28 2 16
Average= 3.22
(KJ/cycle)

Cycle 45 GMT 1/ 3/2020 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.80 24 15.15 636 231 0.23 / 143.58 2 4
2 7 2003.08 29 15.03 2942 1282 1.51 / 144.86 2 5
3 13 1605.32 17 15.03 2484 635 2.15 / 145.50 2 4
4 13 1031.68 17 15.10 1766 453 2.60 / 145.95 2 6
5 13 466.60 17 15.20 1043 270 2.87 / 146.22 2 7
6 13 43.52 17 15.29 479 125 3.00 / 146.34 2 8
7 8 0.08 165 15.25 391 984 3.98 / 147.33 2 21
Average= 3.20
(KJ/cycle)

Cycle 44 GMT 20/ 2/2020 3:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.56 23 15.15 643 224 0.22 / 139.47 2 5
2 7 2003.72 30 15.03 2948 1329 1.55 / 140.80 2 5
3 13 1727.68 17 15.02 2627 671 2.22 / 141.47 2 4
4 13 1139.88 17 15.08 1898 487 2.71 / 141.96 2 6
5 13 420.24 17 15.22 985 255 2.97 / 142.21 2 8
6 13 56.52 17 15.29 496 129 3.09 / 142.34 2 8
7 8 0.12 165 15.25 400 1006 4.10 / 143.35 2 18
Average= 3.19
(KJ/cycle)

Cycle 43 GMT 10/ 2/2020 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.24 23 15.16 630 220 0.22 / 135.52 2 4
2 3 1041.92 1 15.21 1841 28 0.25 / 135.55 2 4
3 7 2006.52 29 15.04 2952 1288 1.54 / 136.83 2 4
4 13 1611.00 17 15.04 2486 636 2.17 / 137.47 2 4
5 13 1049.72 17 15.10 1792 460 2.63 / 137.93 2 6
6 13 479.88 17 15.20 1060 274 2.90 / 138.20 2 7
7 13 56.24 5 15.31 507 39 2.94 / 138.24 2 7
8 8 0.44 165 15.26 399 1005 3.95 / 139.25 2 13
Average= 3.16
(KJ/cycle)

Cycle 42 GMT 31/ 1/2020 6:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.60 21 15.16 633 202 0.20 / 131.58 2 5
2 10 1038.88 2 15.13 1846 56 0.26 / 131.63 2 4
3 7 2002.52 29 15.02 2945 1283 1.54 / 132.92 2 3
4 13 1589.40 17 15.04 2467 631 2.17 / 133.55 2 5
5 13 1005.80 17 15.11 1741 447 2.62 / 133.99 2 8
6 13 435.96 17 15.21 1000 259 2.88 / 134.25 2 8
7 13 66.52 6 15.30 515 47 2.92 / 134.30 2 8
8 8 -0.24 165 15.26 396 997 3.92 / 135.30 2 16
Average= 3.15
(KJ/cycle)

Cycle 41 GMT 21/ 1/2020 7:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1099.88 8 15.03 1920 231 0.23 / 127.07 2 3
2 10 1183.64 6 15.02 2031 183 0.41 / 127.25 2 3
3 10 1235.04 4 15.01 2098 126 0.54 / 127.38 2 4
4 3 1261.44 8 15.08 2150 259 0.80 / 127.64 2 4
5 7 2004.12 30 15.02 2943 1326 2.13 / 128.97 2 6
6 13 1597.00 17 15.04 2477 633 2.76 / 129.60 2 4
7 13 1035.56 17 15.11 1779 457 3.22 / 130.06 2 6
8 13 452.76 17 15.21 1030 266 3.48 / 130.32 2 7
9 13 51.84 5 15.30 517 40 3.52 / 130.36 2 8
10 8 0.32 165 15.26 403 1015 4.54 / 131.38 2 17
Average= 3.13
(KJ/cycle)

Cycle 40 GMT 11/ 1/2020 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 827.88 -6 15.58 4 0 0.00 / 123.06 2 2
2 3 983.24 -1 15.60 4 0 0.00 / 123.06 2 2
3 7 2007.00 30 15.03 2954 1332 1.33 / 124.39 2 4
4 13 1604.64 17 15.04 2491 637 1.97 / 125.02 2 4
5 13 1024.12 17 15.11 1772 455 2.42 / 125.48 2 6
6 13 436.72 17 15.22 1010 261 2.69 / 125.74 2 7
7 13 67.16 6 15.30 526 48 2.73 / 125.79 2 8
8 13 44.00 5 15.31 507 39 2.77 / 125.83 2 8
9 8 0.48 165 15.26 402 1012 3.79 / 126.84 2 19
Average= 3.09
(KJ/cycle)

Cycle 39

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 842.28 -6 15.58 3 0 0.00 / 120.37 2 2
2 7 2002.88 29 15.03 2944 1283 1.28 / 121.65 2 4
3 13 1586.32 17 15.05 2461 630 1.91 / 122.28 2 6
4 13 1033.72 17 15.10 1788 459 2.37 / 122.74 2 6
5 13 447.04 17 15.22 1026 265 2.64 / 123.01 2 7
6 13 71.44 6 15.30 540 50 2.69 / 123.06 2 8
Average= 3.08
(KJ/cycle)

Cycle 38

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 807.36 -7 15.59 4 0 0.00 / 117.61 2 2
2 7 2003.60 30 15.03 2952 1331 1.33 / 118.94 2 4
3 13 1584.72 17 15.04 2472 632 1.96 / 119.58 2 4
4 13 1017.96 17 15.11 1760 452 2.42 / 120.03 2 5
5 13 442.32 17 15.22 1021 264 2.68 / 120.29 2 7
6 13 51.72 5 15.31 512 39 2.72 / 120.33 2 8
7 13 41.56 5 15.31 500 38 2.76 / 120.37 2 8
Average= 3.09
(KJ/cycle)

Cycle 37

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 790.28 -8 15.59 4 0 0.00 / 114.94 2 2
2 7 2003.00 29 15.04 2951 1287 1.29 / 116.23 2 6
3 13 1593.32 17 15.05 2464 630 1.92 / 116.86 2 5
4 13 1015.04 17 15.12 1755 451 2.37 / 117.31 2 5
5 13 432.00 17 15.23 1006 260 2.63 / 117.57 2 7
6 13 50.84 5 15.31 508 39 2.67 / 117.61 2 8
Average= 3.10
(KJ/cycle)

Cycle 36

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 802.40 -7 15.59 4 0 0.00 / 112.25 2 2
2 3 971.64 -1 15.61 4 0 0.00 / 112.25 2 2
3 7 2003.36 29 15.05 2954 1289 1.29 / 113.54 2 5
4 13 1600.80 17 15.05 2484 636 1.93 / 114.18 2 4
5 13 1038.64 17 15.12 1787 459 2.38 / 114.64 2 6
6 13 458.16 17 15.22 1038 269 2.65 / 114.90 2 7
7 13 53.80 5 15.32 513 39 2.69 / 114.94 2 7
Average= 3.11
(KJ/cycle)

Cycle 35

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 791.12 -8 15.59 4 0 0.00 / 109.57 2 2
2 7 2002.96 29 15.04 2948 1286 1.29 / 110.85 2 3
3 13 1589.32 17 15.05 2469 632 1.92 / 111.48 2 5
4 13 1015.60 17 15.12 1761 453 2.37 / 111.94 2 6
5 13 445.20 17 15.22 1024 265 2.64 / 112.20 2 7
6 13 72.40 6 15.30 542 50 2.69 / 112.25 2 8
Average= 3.12
(KJ/cycle)

Cycle 34

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 794.32 -7 15.59 4 0 0.00 / 106.86 2 2
2 3 968.92 -1 15.61 3 0 0.00 / 106.86 2 2
3 7 2005.32 29 15.03 2958 1289 1.29 / 108.15 2 4
4 13 1594.12 17 15.05 2485 636 1.93 / 108.79 2 4
5 13 1026.12 17 15.12 1778 457 2.38 / 109.25 2 6
6 13 462.36 17 15.21 1053 272 2.65 / 109.52 2 7
7 13 76.88 6 15.31 545 50 2.70 / 109.57 2 8
Average= 3.13
(KJ/cycle)

Cycle 33

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 785.52 -8 15.59 4 0 0.00 / 104.18 2 2
2 3 986.08 -1 15.61 3 0 0.00 / 104.18 2 2
3 7 2005.32 29 15.03 2951 1286 1.29 / 105.47 2 4
4 13 1594.56 17 15.05 2473 633 1.92 / 106.10 2 5
5 13 1025.72 17 15.12 1773 456 2.38 / 106.55 2 6
6 13 451.76 17 15.22 1038 269 2.64 / 106.82 2 8
7 13 51.72 5 15.32 517 40 2.68 / 106.86 2 8
Average= 3.14
(KJ/cycle)

Cycle 32

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 766.28 -8 15.59 4 0 0.00 / 101.49 2 2
2 3 968.36 -1 15.61 4 0 0.00 / 101.49 2 2
3 7 2002.68 29 15.03 2959 1290 1.29 / 102.78 2 4
4 13 1578.88 17 15.05 2462 630 1.92 / 103.41 2 5
5 13 1023.68 17 15.12 1776 457 2.38 / 103.86 2 6
6 13 452.40 17 15.23 1034 268 2.64 / 104.13 2 7
7 13 72.76 6 15.31 545 50 2.69 / 104.18 2 8
Average= 3.16
(KJ/cycle)

Cycle 31

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 779.80 -8 15.60 4 0 0.00 / 98.80 2 2
2 3 983.40 -1 15.62 4 0 0.00 / 98.80 2 2
3 7 2006.92 29 15.04 2964 1293 1.29 / 100.09 2 3
4 13 1598.56 17 15.05 2487 636 1.93 / 100.72 2 4
5 13 1020.00 17 15.12 1764 453 2.38 / 101.18 2 5
6 13 447.96 17 15.23 1034 268 2.65 / 101.45 2 7
7 13 52.96 5 15.32 533 41 2.69 / 101.49 2 8
Average= 3.17
(KJ/cycle)

Cycle 30

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 749.44 -9 15.60 4 0 0.00 / 96.10 2 2
2 3 979.68 -1 15.62 4 0 0.00 / 96.10 2 2
3 7 2005.84 29 15.04 2957 1290 1.29 / 97.39 2 5
4 13 1593.48 17 15.06 2474 633 1.92 / 98.02 2 4
5 13 1030.76 17 15.13 1783 459 2.38 / 98.48 2 5
6 13 451.44 17 15.23 1028 266 2.65 / 98.75 2 7
7 13 72.60 6 15.32 540 50 2.70 / 98.80 2 8
Average= 3.19
(KJ/cycle)

Cycle 29

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 755.56 -9 15.60 4 0 0.00 / 93.43 2 2
2 3 980.60 -1 15.62 4 0 0.00 / 93.43 2 2
3 7 2002.68 29 15.05 2947 1286 1.29 / 94.72 2 5
4 13 1574.84 17 15.07 2443 626 1.91 / 95.34 2 6
5 13 1161.08 17 15.11 1938 498 2.41 / 95.84 2 6
6 13 418.08 17 15.25 990 257 2.67 / 96.10 2 7
Average= 3.20
(KJ/cycle)

Cycle 28

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 768.80 -8 15.61 4 0 0.00 / 90.76 2 2
2 3 967.40 -1 15.62 3 0 0.00 / 90.76 2 2
3 7 2002.72 29 15.05 2949 1287 1.29 / 92.04 2 4
4 13 1583.80 17 15.07 2461 630 1.92 / 92.67 2 4
5 13 1023.64 17 15.13 1766 454 2.37 / 93.13 2 5
6 13 433.88 17 15.24 1012 262 2.63 / 93.39 2 7
7 13 49.44 5 15.33 519 40 2.67 / 93.43 2 8
Average= 3.22
(KJ/cycle)

Cycle 27

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 799.24 -7 15.61 4 0 0.00 / 88.08 2 2
2 3 972.84 -1 15.63 4 0 0.00 / 88.08 2 2
3 7 2002.16 29 15.05 2945 1285 1.29 / 89.36 2 3
4 13 1588.24 17 15.07 2468 632 1.92 / 90.00 2 4
5 13 1015.04 17 15.14 1757 452 2.37 / 90.45 2 5
6 13 451.28 17 15.24 1037 269 2.64 / 90.72 2 7
7 13 52.72 5 15.33 523 40 2.68 / 90.76 2 8
Average= 3.24
(KJ/cycle)

Cycle 26

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 776.68 -8 15.61 4 0 0.00 / 85.33 2 2
2 3 982.56 -1 15.63 4 0 0.00 / 85.33 2 2
3 7 2002.24 29 15.07 2958 1293 1.29 / 86.62 2 3
4 13 1600.28 17 15.07 2486 637 1.93 / 87.26 2 4
5 13 1031.60 17 15.14 1785 459 2.39 / 87.72 2 5
6 13 459.64 17 15.24 1049 272 2.66 / 87.99 2 7
7 13 76.08 6 15.33 546 50 2.71 / 88.04 2 8
8 13 45.40 5 15.33 514 39 2.75 / 88.08 2 8
Average= 3.26
(KJ/cycle)

Cycle 25

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 747.76 -9 15.61 4 0 0.00 / 82.57 2 2
2 3 976.04 -1 15.63 4 0 0.00 / 82.57 2 2
3 7 2003.84 30 15.05 2950 1332 1.33 / 83.90 2 3
4 13 1580.64 17 15.08 2450 628 1.96 / 84.53 2 4
5 13 1141.76 17 15.12 1917 493 2.45 / 85.02 2 5
6 13 414.12 17 15.25 988 256 2.71 / 85.28 2 7
7 13 63.76 6 15.33 538 49 2.76 / 85.33 2 8
Average= 3.28
(KJ/cycle)

Cycle 24

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 786.28 -8 15.61 4 0 0.00 / 79.84 2 2
2 7 2002.08 29 15.07 2961 1294 1.29 / 81.14 2 3
3 13 1606.20 17 15.07 2498 640 1.93 / 81.78 2 4
4 13 1053.24 17 15.14 1812 466 2.40 / 82.25 2 5
5 13 466.96 17 15.24 1057 274 2.67 / 82.52 2 7
6 13 79.88 6 15.33 554 51 2.73 / 82.57 2 8
Average= 3.30
(KJ/cycle)

Cycle 23

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 773.00 -8 15.62 3 0 0.00 / 77.20 2 2
2 3 977.04 -1 15.63 4 0 0.00 / 77.20 2 2
3 7 2001.08 29 15.06 2950 1288 1.29 / 78.48 2 3
4 13 1456.36 17 15.10 2306 592 1.88 / 79.08 2 4
5 13 1035.68 17 15.15 1786 460 2.34 / 79.54 2 5
6 13 451.24 17 15.25 1034 268 2.61 / 79.80 2 7
7 13 52.36 5 15.34 521 40 2.65 / 79.84 2 8
Average= 3.33
(KJ/cycle)

Cycle 22

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 749.56 -9 15.62 4 0 0.00 / 74.51 2 2
2 3 977.28 -1 15.64 4 0 0.00 / 74.51 2 2
3 7 2003.68 29 15.06 2952 1289 1.29 / 75.80 2 3
4 13 1581.40 17 15.08 2461 631 1.92 / 76.44 2 4
5 13 1011.32 17 15.15 1748 450 2.37 / 76.89 2 5
6 13 431.68 17 15.26 1010 262 2.63 / 77.15 2 7
7 13 65.12 6 15.34 532 49 2.68 / 77.20 2 8
Average= 3.36
(KJ/cycle)

Cycle 21

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 757.72 -9 15.62 3 0 0.00 / 71.87 2 2
2 3 983.08 -1 15.64 4 0 0.00 / 71.87 2 2
3 7 2001.80 29 15.07 2967 1297 1.30 / 73.17 2 3
4 13 1584.36 17 15.08 2461 631 1.93 / 73.80 2 4
5 13 1005.76 17 15.16 1755 452 2.38 / 74.25 2 5
6 13 429.72 17 15.26 1013 263 2.64 / 74.51 2 7
Average= 3.39
(KJ/cycle)

Cycle 20

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 769.68 -8 15.62 4 0 0.00 / 69.17 2 2
2 3 973.04 -1 15.64 3 0 0.00 / 69.17 2 2
3 7 2001.72 29 15.07 2946 1287 1.29 / 70.46 2 3
4 13 1718.48 17 15.07 2625 672 1.96 / 71.13 2 4
5 13 978.08 17 15.17 1709 441 2.40 / 71.58 2 5
6 13 539.28 17 15.24 1146 297 2.70 / 71.87 2 7
Average= 3.42
(KJ/cycle)

Cycle 19

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 766.36 -8 15.63 4 0 0.00 / 66.52 2 2
2 3 972.48 -1 15.65 5 0 0.00 / 66.52 2 2
3 7 2001.60 29 15.07 2944 1287 1.29 / 67.80 2 3
4 13 1456.16 17 15.11 2311 594 1.88 / 68.40 2 4
5 13 1045.12 17 15.15 1795 462 2.34 / 68.86 2 5
6 13 469.96 17 15.25 1061 275 2.62 / 69.14 2 7
7 13 51.36 5 15.35 515 40 2.66 / 69.17 2 8
Average= 3.46
(KJ/cycle)

Cycle 18

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 776.76 -8 15.63 4 0 0.00 / 63.85 2 2
2 3 982.92 -1 15.65 4 0 0.00 / 63.85 2 2
3 7 2004.16 29 15.08 2945 1288 1.29 / 65.14 2 3
4 13 1577.52 17 15.10 2453 630 1.92 / 65.77 2 4
5 13 1010.36 17 15.17 1753 452 2.37 / 66.22 2 5
6 13 425.36 17 15.27 1003 260 2.63 / 66.48 2 7
7 13 49.08 5 15.36 511 39 2.67 / 66.52 2 8
Average= 3.50
(KJ/cycle)

Cycle 17

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 767.96 -8 15.63 4 0 0.00 / 61.17 2 2
2 3 973.24 -1 15.65 4 0 0.00 / 61.17 2 2
3 7 2000.88 29 15.08 2952 1291 1.29 / 62.46 2 3
4 13 1580.04 17 15.10 2457 631 1.92 / 63.09 2 4
5 13 1017.48 17 15.17 1758 453 2.38 / 63.54 2 5
6 13 420.08 17 15.27 994 258 2.63 / 63.80 2 7
7 13 60.68 6 15.35 523 48 2.68 / 63.85 2 8
Average= 3.55
(KJ/cycle)

Cycle 16

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.44 21 15.31 647 208 0.21 / 58.48 2 7
2 3 87.88 -33 15.63 4 0 0.00 / 58.48 2 7
3 3 666.32 -12 15.64 4 0 0.00 / 58.48 2 7
4 7 2001.68 29 15.09 2946 1289 1.50 / 59.77 2 3
5 13 1601.44 17 15.11 2484 638 2.14 / 60.41 2 4
6 13 1020.08 17 15.18 1757 453 2.59 / 60.86 2 5
7 13 454.32 17 15.27 1031 268 2.86 / 61.13 2 7
8 13 44.76 5 15.36 495 38 2.89 / 61.17 2 8
Average= 3.60
(KJ/cycle)

Cycle 15

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.60 21 15.25 637 204 0.20 / 55.63 2 6
2 3 986.04 -1 15.62 4 0 0.00 / 55.63 2 6
3 7 2002.92 29 15.09 2948 1290 1.49 / 56.92 2 3
4 13 1458.08 17 15.13 2307 593 2.09 / 57.51 2 4
5 13 1033.80 17 15.17 1778 459 2.55 / 57.97 2 5
6 13 444.60 17 15.27 1016 264 2.81 / 58.23 2 7
7 13 49.88 5 15.37 502 39 2.85 / 58.27 2 8
Average= 3.64
(KJ/cycle)

Cycle 14 GMT 28/ 4/2019 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.32 20 15.25 643 196 0.20 / 51.73 2 6
2 3 1040.64 1 15.28 1860 28 0.22 / 51.76 2 4
3 7 2003.04 28 15.10 2951 1248 1.47 / 53.01 2 3
4 13 1599.88 17 15.11 2476 636 2.11 / 53.65 2 4
5 13 1024.24 17 15.18 1764 455 2.56 / 54.10 2 5
6 13 443.36 17 15.28 1015 264 2.83 / 54.36 2 7
7 13 50.56 5 15.37 501 39 2.87 / 54.40 2 8
8 8 0.00 165 15.32 404 1021 3.89 / 55.42 2 17
Average= 3.69
(KJ/cycle)

Cycle 13 GMT 18/ 4/2019 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.56 21 15.25 644 206 0.21 / 47.88 2 6
2 3 980.88 -1 15.62 4 0 0.00 / 47.88 2 6
3 7 2002.48 28 15.11 2949 1248 1.45 / 49.12 2 3
4 13 1588.80 17 15.12 2463 633 2.09 / 49.76 2 4
5 13 1007.08 17 15.19 1743 450 2.54 / 50.21 2 5
6 13 440.80 17 15.28 1016 264 2.80 / 50.47 2 7
7 13 51.28 5 15.37 510 39 2.84 / 50.51 2 8
8 8 -0.12 165 15.33 406 1027 3.87 / 51.54 2 15
Average= 3.68
(KJ/cycle)

Cycle 12 GMT 8/ 4/2019 9:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.24 21 15.26 635 203 0.20 / 44.00 2 6
2 3 968.24 -1 15.62 4 0 0.00 / 44.00 2 6
3 7 2001.80 28 15.11 2950 1248 1.45 / 45.25 2 3
4 13 1586.96 17 15.12 2468 634 2.09 / 45.88 2 4
5 13 1023.56 17 15.18 1767 456 2.54 / 46.34 2 5
6 13 443.12 17 15.28 1020 265 2.81 / 46.60 2 7
7 13 49.72 5 15.38 506 39 2.85 / 46.64 2 8
8 8 0.08 165 15.33 406 1027 3.87 / 47.67 2 14
Average= 3.67
(KJ/cycle)

Cycle 11 GMT 29/ 3/2019 10:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.24 21 15.24 659 211 0.21 / 40.04 2 5
2 10 1005.36 2 15.21 1819 55 0.27 / 40.10 2 4
3 3 946.00 -2 15.62 4 0 0.06 / 40.10 2 4
4 7 2001.52 28 15.11 2943 1245 1.51 / 41.34 2 3
5 13 1581.16 17 15.13 2453 631 2.14 / 41.97 2 4
6 13 1023.68 17 15.19 1764 456 2.60 / 42.43 2 5
7 13 441.68 17 15.29 1010 263 2.86 / 42.69 2 7
8 13 53.44 5 15.38 516 40 2.90 / 42.73 2 8
9 13 46.52 5 15.38 503 39 2.94 / 42.77 2 8
10 8 0.48 165 15.33 407 1029 3.97 / 43.80 2 18
Average= 3.65
(KJ/cycle)

Cycle 10 GMT 19/ 3/2019 12:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.60 20 15.25 662 202 0.20 / 35.90 2 5
2 10 1033.36 2 15.21 1857 56 0.26 / 35.95 2 4
3 3 980.84 -1 15.62 4 0 0.06 / 35.95 2 4
4 7 2002.16 28 15.12 2949 1248 1.51 / 37.20 2 3
5 13 1581.76 17 15.13 2455 631 2.14 / 37.83 2 4
6 13 1003.92 17 15.20 1736 449 2.59 / 38.28 2 5
7 13 435.92 17 15.29 1009 262 2.85 / 38.54 2 7
8 13 51.52 5 15.38 511 39 2.89 / 38.58 2 8
9 8 0.24 165 15.33 407 1029 3.92 / 39.61 2 18
10 14 0.24 35 15.30 406 217 4.14 / 39.83 2 19
Average= 3.62
(KJ/cycle)

Cycle 9 GMT 9/ 3/2019 13:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.72 21 15.26 633 203 0.20 / 31.95 2 5
2 3 961.48 -1 15.63 5 0 0.00 / 31.95 2 5
3 7 2001.88 28 15.11 2952 1249 1.45 / 33.20 2 3
4 13 1588.16 17 15.14 2467 635 2.09 / 33.83 2 4
5 13 1011.88 17 15.20 1751 452 2.54 / 34.28 2 5
6 13 428.44 17 15.30 996 259 2.80 / 34.54 2 7
7 13 30.96 17 15.37 467 122 2.92 / 34.66 2 8
8 8 -0.16 165 15.33 407 1029 3.95 / 35.69 2 17
Average= 3.57
(KJ/cycle)

Cycle 8 GMT 27/ 2/2019 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.52 20 15.26 639 195 0.20 / 27.96 2 5
2 3 1032.16 1 15.32 1850 28 0.22 / 27.99 2 4
3 7 2000.96 28 15.12 2948 1248 1.47 / 29.24 2 3
4 13 1598.96 17 15.13 2472 636 2.11 / 29.87 2 4
5 13 1018.68 17 15.20 1756 454 2.56 / 30.33 2 5
6 13 431.40 17 15.30 1000 260 2.82 / 30.59 2 7
7 13 56.12 17 15.37 498 130 2.95 / 30.72 2 9
8 8 0.08 165 15.33 406 1027 3.98 / 31.74 2 19
Average= 3.53
(KJ/cycle)

Cycle 7 GMT 17/ 2/2019 15:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.28 20 15.27 650 199 0.20 / 24.03 2 5
2 7 1998.76 28 15.13 2940 1246 1.44 / 25.27 2 3
3 13 1588.68 17 15.14 2463 634 2.08 / 25.90 2 4
4 13 1015.04 17 15.20 1745 451 2.53 / 26.36 2 5
5 13 433.72 17 15.30 1003 261 2.79 / 26.62 2 7
6 13 30.92 17 15.38 468 122 2.91 / 26.74 2 8
7 8 0.16 165 15.33 406 1027 3.94 / 27.77 2 18
Average= 3.47
(KJ/cycle)

Cycle 6 GMT 7/ 2/2019 14:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.56 22 15.27 636 214 0.21 / 20.09 2 5
2 3 938.32 -2 15.64 4 0 0.00 / 20.09 2 5
3 7 1992.96 38 15.07 2918 1671 1.88 / 21.76 2 3
4 13 1374.04 17 15.17 2192 565 2.45 / 22.33 2 4
5 13 780.40 17 15.24 1443 374 2.82 / 22.70 2 6
6 13 91.88 6 15.39 557 51 2.88 / 22.75 2 8
7 13 63.68 6 15.39 521 48 2.92 / 22.80 2 8
8 8 0.04 165 15.35 405 1026 3.95 / 23.83 2 21
Average= 3.40
(KJ/cycle)

Cycle 5 GMT 28/ 1/2019 14:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.80 29 15.25 634 280 0.28 / 16.22 2 5
2 3 706.44 -10 15.62 4 0 0.00 / 16.22 2 5
3 3 973.24 -1 15.65 4 0 0.00 / 16.22 2 5
4 7 1987.24 38 15.08 2911 1668 1.95 / 17.89 2 3
5 13 1249.36 17 15.19 2038 526 2.47 / 18.41 2 5
6 13 672.96 17 15.26 1306 339 2.81 / 18.75 2 6
7 13 105.92 7 15.39 570 61 2.87 / 18.81 2 7
8 13 65.48 6 15.39 516 48 2.92 / 18.86 2 8
9 8 0.12 165 15.35 402 1018 3.94 / 19.88 2 16
Average= 3.31
(KJ/cycle)

Cycle 4 GMT 18/ 1/2019 13:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.12 15 15.27 639 146 0.15 / 12.55 2 4
2 10 1051.28 4 15.17 1867 113 0.26 / 12.66 2 3
3 3 1082.44 2 15.27 1911 58 0.32 / 12.72 2 3
4 7 1518.88 38 15.15 2340 1347 1.67 / 14.07 2 3
5 13 1122.32 17 15.19 1876 484 2.15 / 14.55 2 4
6 13 553.96 17 15.28 1141 296 2.45 / 14.85 2 5
7 13 68.92 6 15.38 519 48 2.49 / 14.90 2 6
8 13 52.12 5 15.38 499 38 2.53 / 14.94 2 6
9 8 0.12 165 15.33 396 1002 3.53 / 15.94 2 15
Average= 3.19
(KJ/cycle)

Cycle 3 GMT 17/ 1/2019 14:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.00 11 15.30 630 106 0.11 / 9.03 2 4
2 10 1005.64 5 15.20 1813 138 0.24 / 9.16 2 3
3 3 1027.80 1 15.33 1864 29 0.27 / 9.19 2 3
4 7 1521.72 38 15.15 2345 1350 1.62 / 10.54 2 3
5 13 1115.40 17 15.20 1858 480 2.10 / 11.02 2 4
6 13 536.44 17 15.29 1123 292 2.39 / 11.31 2 5
7 13 62.12 6 15.38 511 47 2.44 / 11.36 2 6
8 13 43.60 5 15.39 491 38 2.48 / 11.40 2 6
9 8 0.04 165 15.34 397 1005 3.48 / 12.40 2 15
Average= 3.10
(KJ/cycle)

Cycle 2 GMT 16/ 1/2019 16:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 32 15.35 552 271 0.27 / 5.25 2 5
2 3 495.88 -10 15.67 4 0 0.00 / 5.25 2 5
3 3 770.44 -4 15.69 4 0 0.00 / 5.25 2 5
4 7 1522.40 74 15.09 2309 2578 2.85 / 7.83 2 4
5 13 65.64 6 15.40 511 47 2.90 / 7.88 2 6
6 13 50.68 5 15.41 495 38 2.93 / 7.92 2 6
7 8 0.12 165 15.36 395 1001 3.94 / 8.92 2 14
Average= 2.97
(KJ/cycle)

Cycle 1 GMT 15/ 1/2019 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 27 15.52 492 206 0.21 / 2.21 2 3
2 3 688.24 -6 15.70 4 0 0.00 / 2.21 2 3
3 3 858.32 -3 15.72 5 0 0.00 / 2.21 2 3
4 7 941.96 74 15.26 1584 1789 1.99 / 4.00 2 4
5 8 -0.08 165 15.42 387 985 2.98 / 4.98 2 17
Average= 2.49
(KJ/cycle)

Cycle 0 GMT 15/ 1/2019 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 27 15.68 505 214 0.21 / 0.21 2 2
2 7 128.44 75 15.64 498 584 0.80 / 0.80 2 3
3 8 0.04 240 15.60 322 1206 2.00 / 2.00 2 21
Average= 2.00
(KJ/cycle)