SIO Argo Site:
Pump Diagnostics Page   



Serial= 8755 WMO= 7900689

Return

←PreviousNext→

Cycle 16 GMT 17/ 5/2019 15:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.84 26 15.23 662 262 0.26 / 63.25 2 6
2 7 2005.28 29 15.04 3005 1311 1.57 / 64.56 2 5
3 13 1470.68 29 15.06 2344 1024 2.60 / 65.58 2 8
4 13 542.16 29 15.23 1163 514 3.11 / 66.09 2 7
5 8 0.16 165 15.31 429 1084 4.19 / 67.18 2 22
Average= 3.95
(KJ/cycle)

Cycle 15 GMT 7/ 5/2019 17:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.64 26 15.23 665 263 0.26 / 58.95 2 7
2 3 972.40 -1 15.62 9 0 0.00 / 58.95 2 7
3 7 2001.44 29 15.04 3005 1311 1.57 / 60.26 2 6
4 13 1569.00 29 15.05 2464 1075 2.65 / 61.34 2 9
5 13 620.16 29 15.21 1267 559 3.21 / 61.90 2 7
6 8 0.68 165 15.32 429 1084 4.29 / 62.98 2 16
Average= 3.94
(KJ/cycle)

Cycle 14 GMT 27/ 4/2019 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.76 26 15.23 680 269 0.27 / 54.61 2 6
2 3 1021.36 1 15.30 1907 29 0.30 / 54.64 2 4
3 7 2002.36 29 15.04 3016 1315 1.61 / 55.95 2 6
4 13 1580.20 29 15.04 2498 1090 2.70 / 57.04 2 9
5 13 626.32 29 15.21 1274 562 3.27 / 57.60 2 8
6 8 -0.24 165 15.32 430 1087 4.35 / 58.69 2 18
Average= 3.91
(KJ/cycle)

Cycle 13 GMT 17/ 4/2019 20:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.28 26 15.23 653 259 0.26 / 50.26 2 5
2 7 2000.56 31 15.04 3007 1402 1.66 / 51.66 2 4
3 13 1436.96 29 15.08 2312 1011 2.67 / 52.67 2 8
4 13 631.08 29 15.21 1290 569 3.24 / 53.24 2 8
5 8 0.20 165 15.32 435 1100 4.34 / 54.34 2 17
Average= 3.88
(KJ/cycle)

Cycle 12 GMT 7/ 4/2019 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.08 26 15.24 659 261 0.26 / 46.17 2 5
2 7 2001.40 30 15.04 3006 1356 1.62 / 47.53 2 5
3 13 1463.40 16 15.11 2369 573 2.19 / 48.10 2 7
4 13 1050.44 16 15.16 1839 446 2.64 / 48.55 2 8
5 13 334.36 14 15.31 905 194 2.83 / 48.74 2 7
6 13 60.92 6 15.37 542 50 2.88 / 48.79 2 8
7 13 18.28 16 15.37 473 116 3.00 / 48.91 2 8
8 8 0.12 165 15.31 431 1089 4.09 / 50.00 2 13
Average= 3.85
(KJ/cycle)

Cycle 11 GMT 28/ 3/2019 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.48 26 15.25 663 263 0.26 / 42.22 2 6
2 7 2001.12 30 15.05 3004 1356 1.62 / 43.57 2 5
3 13 1457.76 16 15.11 2362 571 2.19 / 44.14 2 8
4 13 905.96 16 15.19 1657 403 2.59 / 44.55 2 7
5 13 356.36 14 15.30 936 200 2.79 / 44.75 2 7
6 13 59.04 5 15.38 543 42 2.84 / 44.79 2 8
7 13 48.72 5 15.37 526 40 2.88 / 44.83 2 8
8 8 0.16 165 15.32 429 1084 3.96 / 45.91 2 17
Average= 3.83
(KJ/cycle)

Cycle 10 GMT 19/ 3/2019 0:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.64 26 15.25 653 259 0.26 / 38.13 2 5
2 7 2000.12 30 15.06 3003 1357 1.62 / 39.49 2 5
3 13 1575.04 16 15.10 2500 604 2.22 / 40.09 2 6
4 13 1011.08 16 15.18 1789 435 2.65 / 40.53 2 7
5 13 436.16 16 15.29 1039 254 2.91 / 40.78 2 7
6 13 54.60 5 15.38 542 42 2.95 / 40.82 2 8
7 13 46.68 5 15.38 520 40 2.99 / 40.86 2 8
8 8 0.24 165 15.33 431 1090 4.08 / 41.95 2 19
Average= 3.81
(KJ/cycle)

Cycle 9 GMT 9/ 3/2019 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.36 26 15.24 667 264 0.26 / 33.99 2 5
2 7 1996.52 31 15.06 2991 1396 1.66 / 35.39 2 7
3 13 1564.56 16 15.11 2479 599 2.26 / 35.99 2 6
4 13 1001.84 16 15.18 1784 433 2.69 / 36.42 2 6
5 13 425.04 16 15.29 1024 251 2.94 / 36.67 2 7
6 13 30.44 16 15.38 489 120 3.06 / 36.79 2 8
7 8 0.04 165 15.33 428 1083 4.15 / 37.87 2 18
Average= 3.79
(KJ/cycle)

Cycle 8 GMT 27/ 2/2019 1: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.16 26 15.25 653 259 0.26 / 29.91 2 4
2 7 1993.92 30 15.06 2990 1351 1.61 / 31.26 2 6
3 13 1574.80 16 15.11 2499 604 2.21 / 31.87 2 5
4 13 864.48 16 15.21 1599 389 2.60 / 32.26 2 6
5 13 430.36 16 15.29 1030 252 2.86 / 32.51 2 8
6 13 35.12 16 15.38 501 123 2.98 / 32.63 2 8
7 8 0.12 165 15.33 432 1093 4.07 / 33.73 2 19
Average= 3.75
(KJ/cycle)

Cycle 7 GMT 17/ 2/2019 0:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.76 25 15.26 660 252 0.25 / 25.81 2 5
2 3 1030.80 1 15.31 1903 29 0.28 / 25.83 2 4
3 7 1993.32 30 15.07 2983 1349 1.63 / 27.18 2 6
4 13 1450.08 16 15.13 2336 565 2.20 / 27.75 2 5
5 13 1025.24 16 15.18 1806 439 2.63 / 28.19 2 6
6 13 434.20 16 15.29 1032 252 2.89 / 28.44 2 7
7 13 57.48 16 15.37 528 130 3.02 / 28.57 2 8
8 8 0.08 165 15.33 429 1085 4.10 / 29.65 2 18
Average= 3.71
(KJ/cycle)

Cycle 6 GMT 6/ 2/2019 23:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.44 25 15.26 670 256 0.26 / 21.71 2 5
2 7 1987.24 38 15.03 2966 1694 1.95 / 23.40 2 5
3 13 1228.24 17 15.16 2063 532 2.48 / 23.93 2 7
4 13 651.08 17 15.25 1316 341 2.82 / 24.27 2 8
5 13 100.48 7 15.38 596 64 2.89 / 24.34 2 7
6 13 48.84 5 15.39 528 41 2.93 / 24.38 2 8
7 13 18.24 17 15.38 474 124 3.05 / 24.50 2 9
8 8 -0.08 165 15.34 415 1050 4.10 / 25.55 2 16
Average= 3.65
(KJ/cycle)

Cycle 5 GMT 27/ 1/2019 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.40 29 15.24 654 289 0.29 / 17.65 2 5
2 3 821.40 -6 15.63 10 0 0.00 / 17.65 2 5
3 7 1984.88 38 15.03 2972 1697 1.99 / 19.35 2 8
4 13 1242.68 17 15.15 2075 534 2.52 / 19.88 2 6
5 13 665.00 17 15.25 1337 347 2.87 / 20.23 2 7
6 13 103.84 7 15.38 602 65 2.93 / 20.29 2 8
7 13 65.00 6 15.39 553 51 2.98 / 20.35 2 8
8 8 0.20 165 15.34 437 1106 4.09 / 21.45 2 16
Average= 3.58
(KJ/cycle)

Cycle 4 GMT 17/ 1/2019 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.76 19 15.26 670 194 0.19 / 13.91 2 5
2 10 1006.08 4 15.17 1852 112 0.31 / 14.02 2 6
3 3 1027.88 1 15.31 1921 29 0.34 / 14.05 2 5
4 7 1521.20 38 15.11 2393 1374 1.71 / 15.42 2 5
5 13 1118.56 17 15.17 1921 495 2.21 / 15.92 2 7
6 13 533.16 17 15.26 1166 302 2.51 / 16.22 2 7
7 13 62.80 6 15.38 548 51 2.56 / 16.27 2 8
8 8 0.12 165 15.33 432 1093 3.65 / 17.36 2 17
Average= 3.47
(KJ/cycle)

Cycle 3 GMT 16/ 1/2019 23:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 21 15.28 574 184 0.18 / 9.89 2 5
2 3 958.52 -1 15.65 9 0 0.00 / 9.89 2 5
3 7 1518.00 74 15.03 2363 2628 2.81 / 12.52 2 7
4 13 65.76 6 15.39 549 51 2.86 / 12.57 2 7
5 13 50.80 5 15.39 534 41 2.90 / 12.61 2 7
6 8 0.20 165 15.33 435 1100 4.00 / 13.71 2 15
Average= 3.43
(KJ/cycle)

Cycle 2 GMT 16/ 1/2019 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 32 15.33 582 286 0.29 / 5.85 2 6
2 3 711.16 -5 15.68 9 0 0.00 / 5.85 2 6
3 3 865.12 -3 15.70 9 0 0.00 / 5.85 2 6
4 7 1518.28 75 15.05 2364 2668 2.95 / 8.52 2 6
5 13 63.12 6 15.40 548 51 3.00 / 8.57 2 7
6 13 40.08 5 15.40 517 40 3.04 / 8.61 2 7
7 8 0.24 165 15.34 435 1101 4.15 / 9.71 2 18
Average= 3.24
(KJ/cycle)

Cycle 1 GMT 15/ 1/2019 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 27 15.51 549 230 0.23 / 2.45 2 3
2 3 1036.56 1 15.37 1920 30 0.26 / 2.48 2 3
3 3 1024.00 1 15.41 1896 29 0.29 / 2.51 2 3
4 7 998.00 75 15.22 1715 1958 2.25 / 4.46 2 8
5 8 0.04 165 15.41 432 1098 3.34 / 5.56 2 18
Average= 2.78
(KJ/cycle)

Cycle 0 GMT 14/ 1/2019 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.52 27 15.69 555 235 0.24 / 0.24 3 3
2 7 136.84 74 15.65 547 633 0.87 / 0.87 3 4
3 8 -0.04 240 15.60 360 1348 2.22 / 2.22 2 16
Average= 2.22
(KJ/cycle)