SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 46 | 10.71 | 672 | 331 | 0.33 / 1435.44 | 3 | 4 |
2 | 12 | 1126.60 | 5 | 9.71 | 2064 | 100 | 0.43 / 1435.54 | 3 | 3 |
3 | 12 | 2003.56 | 50 | 8.99 | 3241 | 1457 | 1.89 / 1437.00 | 3 | 3 |
4 | 7 | 2000.28 | 25 | 9.03 | 3244 | 732 | 2.62 / 1437.73 | 3 | 3 |
5 | 13 | 1874.36 | 37 | 9.17 | 3096 | 1050 | 3.67 / 1438.78 | 3 | 3 |
6 | 13 | 1123.00 | 37 | 9.81 | 2076 | 754 | 4.42 / 1439.53 | 3 | 4 |
7 | 13 | 234.60 | 5 | 10.70 | 868 | 46 | 4.47 / 1439.58 | 3 | 7 |
8 | 13 | 199.76 | 5 | 10.73 | 812 | 44 | 4.51 / 1439.62 | 3 | 7 |
9 | 13 | 165.20 | 5 | 10.77 | 751 | 40 | 4.55 / 1439.66 | 3 | 7 |
10 | 13 | 128.20 | 5 | 10.80 | 708 | 38 | 4.59 / 1439.70 | 3 | 7 |
11 | 13 | 17.16 | 37 | 10.85 | 531 | 213 | 4.81 / 1439.92 | 3 | 6 |
12 | 8 | 0.36 | 190 | 10.88 | 483 | 998 | 5.80 / 1440.91 | 3 | 12 |
Average= | 480.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 46 | 10.70 | 659 | 324 | 0.32 / 1429.65 | 3 | 5 |
2 | 12 | 1105.52 | 5 | 9.73 | 2011 | 98 | 0.42 / 1429.75 | 3 | 3 |
3 | 12 | 2004.56 | 50 | 8.97 | 3273 | 1468 | 1.89 / 1431.22 | 3 | 3 |
4 | 7 | 2001.68 | 25 | 9.01 | 3268 | 736 | 2.63 / 1431.96 | 3 | 3 |
5 | 13 | 1961.04 | 37 | 9.15 | 3185 | 1078 | 3.70 / 1433.03 | 3 | 3 |
6 | 13 | 1196.12 | 37 | 9.74 | 2180 | 786 | 4.49 / 1433.82 | 3 | 4 |
7 | 13 | 336.84 | 7 | 10.57 | 1007 | 75 | 4.56 / 1433.89 | 3 | 6 |
8 | 13 | 257.16 | 5 | 10.67 | 901 | 48 | 4.61 / 1433.94 | 3 | 7 |
9 | 13 | 133.60 | 5 | 10.80 | 728 | 39 | 4.65 / 1433.98 | 3 | 7 |
10 | 13 | 96.92 | 5 | 10.82 | 672 | 36 | 4.69 / 1434.02 | 3 | 7 |
11 | 13 | 46.20 | 5 | 10.88 | 602 | 33 | 4.72 / 1434.05 | 3 | 7 |
12 | 13 | 43.00 | 5 | 10.87 | 594 | 32 | 4.75 / 1434.08 | 3 | 7 |
13 | 8 | -0.28 | 190 | 10.86 | 497 | 1026 | 5.78 / 1435.11 | 3 | 10 |
Average= | 717.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 48 | 10.72 | 656 | 338 | 0.34 / 1425.40 | 3 | 5 |
2 | 3 | 718.28 | -7 | 10.72 | 656 | 0 | 0.00 / 1425.40 | 3 | 5 |
3 | 3 | 961.68 | -1 | 10.72 | 656 | 0 | 0.00 / 1425.40 | 3 | 5 |
4 | 12 | 1154.84 | 50 | 9.49 | 2088 | 991 | 1.33 / 1426.39 | 3 | 3 |
5 | 7 | 1156.44 | 25 | 9.58 | 2108 | 505 | 1.83 / 1426.89 | 3 | 3 |
6 | 13 | 1130.60 | 37 | 9.64 | 2070 | 738 | 2.57 / 1427.63 | 3 | 4 |
7 | 13 | 504.00 | 37 | 10.32 | 1174 | 448 | 3.02 / 1428.08 | 3 | 5 |
8 | 13 | 55.64 | 5 | 10.83 | 616 | 33 | 3.05 / 1428.11 | 3 | 6 |
9 | 13 | 4.04 | 37 | 10.82 | 516 | 207 | 3.26 / 1428.32 | 3 | 6 |
10 | 8 | 0.80 | 190 | 10.83 | 491 | 1010 | 4.27 / 1429.33 | 3 | 11 |
Average= | 1429.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 47 | 10.75 | 668 | 338 | 0.34 / 1419.61 | 3 | 4 |
2 | 12 | 1123.08 | 5 | 9.83 | 2034 | 100 | 0.44 / 1419.71 | 3 | 3 |
3 | 12 | 2006.04 | 50 | 9.17 | 3247 | 1489 | 1.93 / 1421.20 | 3 | 3 |
4 | 7 | 2002.76 | 25 | 9.20 | 3263 | 750 | 2.68 / 1421.95 | 3 | 3 |
5 | 13 | 1797.88 | 37 | 9.38 | 2980 | 1034 | 3.71 / 1422.98 | 3 | 3 |
6 | 13 | 967.76 | 37 | 10.02 | 1872 | 694 | 4.40 / 1423.68 | 3 | 5 |
7 | 13 | 185.56 | 5 | 10.76 | 824 | 44 | 4.45 / 1423.72 | 3 | 7 |
8 | 13 | 148.48 | 5 | 10.81 | 749 | 40 | 4.49 / 1423.76 | 3 | 7 |
9 | 13 | 110.84 | 5 | 10.85 | 690 | 37 | 4.53 / 1423.80 | 3 | 6 |
10 | 13 | 75.36 | 5 | 10.89 | 634 | 35 | 4.56 / 1423.83 | 3 | 6 |
11 | 13 | 57.24 | 5 | 10.91 | 608 | 33 | 4.59 / 1423.87 | 3 | 6 |
12 | 13 | 5.04 | 37 | 10.88 | 513 | 207 | 4.80 / 1424.07 | 3 | 10 |
13 | 8 | -0.08 | 190 | 10.90 | 476 | 986 | 5.79 / 1425.06 | 3 | 10 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 47 | 10.72 | 665 | 335 | 0.34 / 1413.85 | 3 | 4 |
2 | 12 | 1126.68 | 5 | 9.82 | 2046 | 100 | 0.44 / 1413.95 | 3 | 3 |
3 | 12 | 2001.72 | 50 | 9.14 | 3246 | 1483 | 1.92 / 1415.43 | 3 | 3 |
4 | 7 | 1998.40 | 25 | 9.18 | 3228 | 741 | 2.66 / 1416.17 | 3 | 3 |
5 | 13 | 1873.80 | 37 | 9.21 | 3286 | 1120 | 3.78 / 1417.29 | 3 | 3 |
6 | 13 | 1138.40 | 37 | 9.88 | 2103 | 769 | 4.55 / 1418.06 | 3 | 4 |
7 | 13 | 389.84 | 8 | 10.55 | 1087 | 92 | 4.64 / 1418.15 | 3 | 7 |
8 | 13 | 179.84 | 5 | 10.76 | 814 | 44 | 4.68 / 1418.19 | 3 | 7 |
9 | 13 | 50.76 | 5 | 10.90 | 606 | 33 | 4.72 / 1418.23 | 3 | 6 |
10 | 13 | 45.44 | 5 | 10.89 | 594 | 32 | 4.75 / 1418.26 | 3 | 6 |
11 | 8 | 0.28 | 190 | 10.88 | 490 | 1013 | 5.76 / 1419.27 | 3 | 10 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 46 | 10.70 | 648 | 319 | 0.32 / 1407.85 | 3 | 4 |
2 | 3 | 1035.92 | 1 | 10.02 | 1971 | 20 | 0.34 / 1407.87 | 3 | 3 |
3 | 3 | 1020.56 | 1 | 10.01 | 2026 | 20 | 0.36 / 1407.89 | 3 | 3 |
4 | 12 | 1140.96 | 5 | 9.76 | 2108 | 103 | 0.46 / 1407.99 | 3 | 3 |
5 | 12 | 2001.28 | 50 | 9.07 | 3251 | 1474 | 1.94 / 1409.46 | 3 | 3 |
6 | 7 | 1998.04 | 25 | 9.12 | 3256 | 742 | 2.68 / 1410.21 | 3 | 3 |
7 | 13 | 1874.00 | 37 | 9.23 | 3177 | 1085 | 3.76 / 1411.29 | 3 | 3 |
8 | 13 | 1202.76 | 37 | 9.79 | 2203 | 798 | 4.56 / 1412.09 | 3 | 4 |
9 | 13 | 299.32 | 6 | 10.62 | 984 | 63 | 4.62 / 1412.15 | 3 | 7 |
10 | 13 | 142.28 | 5 | 10.78 | 756 | 41 | 4.66 / 1412.19 | 3 | 7 |
11 | 13 | 103.52 | 5 | 10.81 | 691 | 37 | 4.70 / 1412.23 | 3 | 6 |
12 | 13 | 52.96 | 5 | 10.87 | 615 | 33 | 4.74 / 1412.26 | 3 | 6 |
13 | 13 | 46.40 | 5 | 10.88 | 586 | 32 | 4.77 / 1412.30 | 3 | 6 |
14 | 13 | 16.60 | 37 | 10.85 | 525 | 211 | 4.98 / 1412.51 | 3 | 6 |
15 | 8 | 0.12 | 190 | 10.87 | 486 | 1004 | 5.98 / 1413.51 | 3 | 11 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 44 | 10.76 | 641 | 303 | 0.30 / 1403.44 | 3 | 3 |
2 | 10 | 1000.44 | 3 | 10.08 | 1906 | 58 | 0.36 / 1403.50 | 3 | 3 |
3 | 3 | 1041.08 | 1 | 10.09 | 1996 | 20 | 0.38 / 1403.52 | 3 | 3 |
4 | 12 | 1145.80 | 50 | 9.60 | 2058 | 988 | 1.37 / 1404.51 | 3 | 3 |
5 | 7 | 1147.20 | 25 | 9.66 | 2062 | 498 | 1.87 / 1405.00 | 3 | 3 |
6 | 13 | 1117.96 | 37 | 9.72 | 2035 | 732 | 2.60 / 1405.74 | 3 | 4 |
7 | 13 | 684.68 | 37 | 10.15 | 1446 | 543 | 3.14 / 1406.28 | 3 | 5 |
8 | 13 | 44.48 | 5 | 10.84 | 586 | 32 | 3.17 / 1406.31 | 3 | 6 |
9 | 13 | 41.72 | 5 | 10.81 | 591 | 32 | 3.21 / 1406.34 | 3 | 6 |
10 | 13 | 16.80 | 37 | 10.81 | 518 | 207 | 3.41 / 1406.55 | 3 | 7 |
11 | 8 | 0.08 | 190 | 10.83 | 476 | 979 | 4.39 / 1407.53 | 3 | 10 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 47 | 10.96 | 664 | 342 | 0.34 / 1399.26 | 3 | 4 |
2 | 12 | 1135.04 | 50 | 10.32 | 2067 | 1067 | 1.41 / 1400.32 | 3 | 3 |
3 | 7 | 1135.84 | 25 | 10.11 | 2078 | 525 | 1.93 / 1400.85 | 3 | 3 |
4 | 13 | 1104.28 | 37 | 10.09 | 2014 | 752 | 2.69 / 1401.60 | 3 | 4 |
5 | 13 | 396.32 | 9 | 10.75 | 1080 | 104 | 2.79 / 1401.70 | 3 | 6 |
6 | 13 | 316.08 | 6 | 10.80 | 971 | 63 | 2.85 / 1401.77 | 3 | 7 |
7 | 13 | 108.20 | 5 | 10.97 | 685 | 38 | 2.89 / 1401.81 | 3 | 6 |
8 | 13 | 72.32 | 5 | 10.99 | 622 | 34 | 2.92 / 1401.84 | 3 | 6 |
9 | 13 | 55.68 | 5 | 10.97 | 634 | 35 | 2.96 / 1401.87 | 3 | 6 |
10 | 13 | 47.60 | 5 | 10.98 | 612 | 34 | 2.99 / 1401.91 | 3 | 6 |
11 | 13 | 17.84 | 37 | 10.95 | 528 | 214 | 3.21 / 1402.12 | 3 | 6 |
12 | 8 | -0.08 | 190 | 10.90 | 490 | 1015 | 4.22 / 1403.14 | 3 | 10 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 45 | 11.21 | 645 | 325 | 0.33 / 1394.95 | 3 | 3 |
2 | 3 | 1059.88 | 2 | 11.20 | 1991 | 45 | 0.37 / 1395.00 | 3 | 3 |
3 | 3 | 1033.08 | 1 | 11.05 | 1989 | 22 | 0.39 / 1395.02 | 3 | 3 |
4 | 12 | 1153.44 | 50 | 9.97 | 2084 | 1039 | 1.43 / 1396.06 | 3 | 3 |
5 | 7 | 1154.44 | 25 | 10.06 | 2087 | 525 | 1.96 / 1396.58 | 3 | 3 |
6 | 13 | 1123.92 | 37 | 10.11 | 2055 | 769 | 2.72 / 1397.35 | 3 | 4 |
7 | 13 | 592.60 | 37 | 10.62 | 1308 | 514 | 3.24 / 1397.87 | 3 | 6 |
8 | 8 | 0.20 | 190 | 11.14 | 495 | 1048 | 4.29 / 1398.91 | 3 | 10 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 45 | 11.33 | 649 | 331 | 0.33 / 1389.14 | 3 | 4 |
2 | 12 | 1130.00 | 5 | 10.89 | 2100 | 114 | 0.45 / 1389.26 | 3 | 3 |
3 | 12 | 2002.08 | 50 | 9.79 | 3247 | 1589 | 2.03 / 1390.85 | 3 | 3 |
4 | 7 | 1998.48 | 25 | 9.80 | 3239 | 794 | 2.83 / 1391.64 | 3 | 3 |
5 | 13 | 1659.64 | 37 | 9.98 | 2801 | 1034 | 3.86 / 1392.67 | 3 | 3 |
6 | 13 | 792.52 | 37 | 10.66 | 1598 | 630 | 4.49 / 1393.30 | 3 | 6 |
7 | 13 | 77.64 | 37 | 11.41 | 609 | 257 | 4.75 / 1393.56 | 3 | 7 |
8 | 8 | 0.20 | 190 | 11.34 | 495 | 1067 | 5.82 / 1394.63 | 3 | 14 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 45 | 11.71 | 651 | 343 | 0.34 / 1384.92 | 3 | 5 |
2 | 12 | 1133.12 | 50 | 10.13 | 2058 | 1042 | 1.39 / 1385.96 | 3 | 3 |
3 | 7 | 1133.92 | 25 | 10.27 | 2085 | 535 | 1.92 / 1386.50 | 3 | 3 |
4 | 13 | 1101.44 | 37 | 10.25 | 2020 | 766 | 2.69 / 1387.26 | 3 | 4 |
5 | 13 | 477.36 | 37 | 11.11 | 1155 | 475 | 3.16 / 1387.74 | 3 | 7 |
6 | 8 | 0.20 | 190 | 11.50 | 492 | 1075 | 4.24 / 1388.81 | 3 | 9 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.72 | 44 | 11.98 | 668 | 352 | 0.35 / 1378.77 | 3 | 4 |
2 | 3 | 1031.56 | 1 | 12.04 | 1976 | 24 | 0.38 / 1378.79 | 3 | 3 |
3 | 12 | 1153.68 | 5 | 12.04 | 2124 | 128 | 0.50 / 1378.92 | 3 | 3 |
4 | 12 | 2003.00 | 50 | 10.58 | 3256 | 1722 | 2.23 / 1380.64 | 3 | 3 |
5 | 7 | 1998.68 | 25 | 10.43 | 3238 | 844 | 3.07 / 1381.49 | 3 | 3 |
6 | 13 | 1599.96 | 37 | 10.61 | 2712 | 1065 | 4.14 / 1382.55 | 3 | 4 |
7 | 13 | 798.72 | 37 | 11.25 | 1587 | 661 | 4.80 / 1383.21 | 3 | 6 |
8 | 13 | 30.16 | 37 | 12.24 | 547 | 248 | 5.04 / 1383.46 | 3 | 7 |
9 | 8 | 0.16 | 190 | 11.89 | 494 | 1116 | 6.16 / 1384.58 | 3 | 18 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 34 | 12.82 | 658 | 287 | 0.29 / 1373.87 | 3 | 3 |
2 | 10 | 1017.72 | 5 | 12.85 | 1933 | 124 | 0.41 / 1373.99 | 3 | 3 |
3 | 10 | 1051.04 | 3 | 12.84 | 2024 | 78 | 0.49 / 1374.07 | 3 | 3 |
4 | 3 | 1060.96 | 2 | 12.52 | 2030 | 51 | 0.54 / 1374.12 | 3 | 3 |
5 | 12 | 1133.72 | 50 | 8.95 | 2068 | 925 | 1.47 / 1375.05 | 3 | 3 |
6 | 7 | 1135.32 | 25 | 9.87 | 2107 | 520 | 1.99 / 1375.57 | 3 | 3 |
7 | 13 | 1109.12 | 37 | 9.95 | 2055 | 757 | 2.74 / 1376.32 | 3 | 3 |
8 | 13 | 854.60 | 37 | 10.80 | 1696 | 678 | 3.42 / 1377.00 | 3 | 5 |
9 | 13 | 16.28 | 37 | 12.74 | 549 | 259 | 3.68 / 1377.26 | 3 | 8 |
10 | 8 | -0.16 | 190 | 12.23 | 497 | 1155 | 4.83 / 1378.42 | 3 | 5 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 42 | 12.94 | 640 | 348 | 0.35 / 1369.34 | 3 | 4 |
2 | 3 | 1065.48 | 2 | 12.44 | 2011 | 50 | 0.40 / 1369.39 | 3 | 3 |
3 | 3 | 1019.68 | 1 | 11.72 | 1971 | 23 | 0.42 / 1369.41 | 3 | 3 |
4 | 12 | 1169.52 | 50 | 8.99 | 2132 | 958 | 1.38 / 1370.37 | 3 | 3 |
5 | 7 | 1171.48 | 25 | 10.24 | 2144 | 549 | 1.93 / 1370.92 | 3 | 3 |
6 | 13 | 1144.76 | 37 | 10.49 | 2062 | 800 | 2.73 / 1371.72 | 3 | 4 |
7 | 13 | 565.52 | 37 | 12.32 | 1240 | 565 | 3.29 / 1372.28 | 3 | 8 |
8 | 13 | 45.64 | 5 | 13.01 | 603 | 39 | 3.33 / 1372.32 | 3 | 8 |
9 | 13 | 42.36 | 5 | 13.01 | 608 | 40 | 3.37 / 1372.36 | 3 | 8 |
10 | 8 | 0.16 | 190 | 12.73 | 505 | 1221 | 4.59 / 1373.58 | 3 | 10 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 35 | 13.23 | 660 | 306 | 0.31 / 1364.59 | 3 | 3 |
2 | 10 | 1063.28 | 5 | 12.88 | 2001 | 129 | 0.43 / 1364.72 | 3 | 3 |
3 | 3 | 1077.40 | 2 | 12.62 | 2110 | 53 | 0.49 / 1364.77 | 3 | 3 |
4 | 3 | 1029.76 | 1 | 12.05 | 2004 | 24 | 0.51 / 1364.80 | 3 | 3 |
5 | 12 | 1144.08 | 50 | 9.66 | 2068 | 999 | 1.51 / 1365.80 | 3 | 3 |
6 | 7 | 1145.12 | 25 | 10.51 | 2114 | 555 | 2.07 / 1366.35 | 3 | 3 |
7 | 13 | 1112.52 | 37 | 10.73 | 2020 | 802 | 2.87 / 1367.15 | 3 | 4 |
8 | 13 | 518.24 | 37 | 12.63 | 1179 | 551 | 3.42 / 1367.71 | 3 | 9 |
9 | 13 | 44.44 | 5 | 13.22 | 618 | 41 | 3.46 / 1367.75 | 3 | 8 |
10 | 8 | 0.32 | 190 | 12.90 | 507 | 1243 | 4.70 / 1368.99 | 3 | 15 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 33 | 13.14 | 654 | 284 | 0.28 / 1358.08 | 3 | 3 |
2 | 10 | 1027.40 | 5 | 12.85 | 1966 | 126 | 0.41 / 1358.21 | 3 | 3 |
3 | 10 | 1062.08 | 3 | 12.90 | 2012 | 78 | 0.49 / 1358.29 | 3 | 4 |
4 | 3 | 1075.24 | 2 | 12.44 | 2066 | 51 | 0.54 / 1358.34 | 3 | 3 |
5 | 3 | 1024.60 | 1 | 11.83 | 1954 | 23 | 0.56 / 1358.36 | 3 | 3 |
6 | 12 | 1130.52 | 5 | 11.93 | 2105 | 126 | 0.69 / 1358.49 | 3 | 3 |
7 | 12 | 2000.40 | 50 | 10.50 | 3248 | 1705 | 2.39 / 1360.19 | 3 | 3 |
8 | 7 | 1996.16 | 25 | 10.52 | 3242 | 853 | 3.25 / 1361.05 | 3 | 3 |
9 | 13 | 1555.12 | 37 | 11.62 | 2656 | 1142 | 4.39 / 1362.19 | 3 | 4 |
10 | 13 | 511.00 | 37 | 13.17 | 1164 | 567 | 4.95 / 1362.75 | 3 | 10 |
11 | 13 | 16.16 | 37 | 13.73 | 554 | 281 | 5.24 / 1363.04 | 3 | 6 |
12 | 8 | -0.40 | 190 | 13.00 | 506 | 1250 | 6.49 / 1364.29 | 3 | 12 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 33 | 13.63 | 662 | 298 | 0.30 / 1353.13 | 3 | 4 |
2 | 3 | 1035.92 | 1 | 11.93 | 1993 | 24 | 0.32 / 1353.16 | 3 | 3 |
3 | 12 | 1146.76 | 50 | 8.03 | 2018 | 810 | 1.13 / 1353.97 | 3 | 3 |
4 | 7 | 1149.40 | 25 | 10.07 | 2088 | 526 | 1.66 / 1354.49 | 3 | 3 |
5 | 13 | 1131.04 | 37 | 10.16 | 2048 | 770 | 2.43 / 1355.26 | 3 | 3 |
6 | 13 | 842.64 | 37 | 11.84 | 1633 | 715 | 3.14 / 1355.98 | 3 | 6 |
7 | 13 | 61.64 | 5 | 13.60 | 613 | 42 | 3.18 / 1356.02 | 3 | 7 |
8 | 13 | 50.48 | 5 | 13.66 | 607 | 41 | 3.23 / 1356.06 | 3 | 7 |
9 | 13 | 16.96 | 37 | 13.75 | 546 | 278 | 3.50 / 1356.34 | 3 | 7 |
10 | 13 | 5.24 | 37 | 13.44 | 523 | 260 | 3.76 / 1356.60 | 3 | 7 |
11 | 8 | -0.32 | 190 | 12.92 | 489 | 1200 | 4.96 / 1357.80 | 3 | 12 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 34 | 13.67 | 650 | 302 | 0.30 / 1349.97 | 3 | 4 |
2 | 3 | 1019.40 | 1 | 11.62 | 1966 | 23 | 0.32 / 1349.99 | 3 | 3 |
3 | 12 | 1147.56 | 50 | 8.49 | 2017 | 856 | 1.18 / 1350.85 | 3 | 3 |
4 | 7 | 1149.80 | 25 | 10.24 | 2093 | 536 | 1.72 / 1351.38 | 3 | 3 |
5 | 13 | 1127.12 | 37 | 10.43 | 2032 | 784 | 2.50 / 1352.17 | 3 | 4 |
6 | 13 | 704.88 | 37 | 12.66 | 1429 | 669 | 3.17 / 1352.84 | 3 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 35 | 13.67 | 658 | 315 | 0.31 / 1346.72 | 3 | 5 |
2 | 3 | 978.32 | -1 | 13.67 | 658 | 0 | 0.00 / 1346.72 | 3 | 5 |
3 | 12 | 1131.84 | 50 | 9.45 | 2029 | 959 | 1.27 / 1347.68 | 3 | 3 |
4 | 7 | 1133.04 | 25 | 10.55 | 2057 | 543 | 1.82 / 1348.22 | 3 | 3 |
5 | 13 | 1100.16 | 37 | 10.83 | 1992 | 798 | 2.61 / 1349.02 | 3 | 4 |
6 | 13 | 654.32 | 37 | 12.96 | 1352 | 648 | 3.26 / 1349.67 | 3 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 33 | 13.64 | 659 | 297 | 0.30 / 1342.12 | 3 | 4 |
2 | 12 | 1123.56 | 5 | 11.64 | 2079 | 121 | 0.42 / 1342.24 | 3 | 3 |
3 | 12 | 2001.24 | 50 | 10.15 | 3259 | 1654 | 2.07 / 1343.89 | 3 | 3 |
4 | 7 | 1997.04 | 25 | 10.30 | 3230 | 832 | 2.90 / 1344.72 | 3 | 3 |
5 | 13 | 1555.04 | 37 | 11.94 | 2620 | 1157 | 4.06 / 1345.88 | 3 | 5 |
6 | 13 | 444.40 | 37 | 13.34 | 1061 | 524 | 4.58 / 1346.40 | 3 | 10 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 34 | 13.69 | 639 | 297 | 0.30 / 1338.97 | 3 | 5 |
2 | 3 | 943.80 | -1 | 13.69 | 639 | 0 | 0.00 / 1338.97 | 3 | 5 |
3 | 12 | 1117.20 | 50 | 8.22 | 1975 | 812 | 1.11 / 1339.79 | 3 | 3 |
4 | 7 | 1119.84 | 25 | 10.26 | 2036 | 522 | 1.63 / 1340.31 | 3 | 3 |
5 | 13 | 1101.04 | 37 | 10.41 | 1992 | 767 | 2.40 / 1341.08 | 3 | 4 |
6 | 13 | 850.36 | 37 | 12.26 | 1638 | 743 | 3.14 / 1341.82 | 3 | 7 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 35 | 13.73 | 654 | 314 | 0.31 / 1335.72 | 3 | 4 |
2 | 12 | 1134.32 | 50 | 8.61 | 2032 | 875 | 1.19 / 1336.59 | 3 | 3 |
3 | 7 | 1136.64 | 25 | 10.39 | 2056 | 534 | 1.72 / 1337.12 | 3 | 3 |
4 | 13 | 1114.28 | 37 | 10.65 | 2009 | 792 | 2.51 / 1337.92 | 3 | 4 |
5 | 13 | 859.80 | 37 | 12.48 | 1647 | 761 | 3.28 / 1338.68 | 3 | 7 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 36 | 13.66 | 659 | 324 | 0.32 / 1332.49 | 3 | 5 |
2 | 3 | 978.60 | -1 | 13.66 | 659 | 0 | 0.00 / 1332.49 | 3 | 5 |
3 | 12 | 1143.12 | 50 | 9.47 | 2064 | 977 | 1.30 / 1333.47 | 3 | 3 |
4 | 7 | 1144.52 | 25 | 10.67 | 2097 | 559 | 1.86 / 1334.03 | 3 | 3 |
5 | 13 | 1114.28 | 37 | 11.04 | 1999 | 817 | 2.68 / 1334.85 | 3 | 4 |
6 | 13 | 481.48 | 37 | 13.31 | 1124 | 554 | 3.23 / 1335.40 | 3 | 10 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 33 | 13.66 | 646 | 291 | 0.29 / 1327.75 | 3 | 5 |
2 | 12 | 1126.88 | 5 | 11.75 | 2097 | 123 | 0.41 / 1327.88 | 3 | 3 |
3 | 12 | 1999.52 | 50 | 10.34 | 3243 | 1677 | 2.09 / 1329.55 | 3 | 3 |
4 | 7 | 1995.32 | 25 | 10.42 | 3228 | 841 | 2.93 / 1330.39 | 3 | 3 |
5 | 13 | 1603.32 | 37 | 12.01 | 2680 | 1191 | 4.12 / 1331.58 | 3 | 5 |
6 | 13 | 534.64 | 37 | 13.31 | 1192 | 587 | 4.71 / 1332.17 | 3 | 11 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 33 | 13.70 | 661 | 299 | 0.30 / 1324.53 | 3 | 4 |
2 | 12 | 1146.48 | 50 | 7.68 | 2006 | 770 | 1.07 / 1325.30 | 3 | 3 |
3 | 7 | 1149.64 | 25 | 10.40 | 2060 | 536 | 1.60 / 1325.84 | 3 | 3 |
4 | 13 | 1135.60 | 37 | 10.56 | 2041 | 797 | 2.40 / 1326.64 | 3 | 4 |
5 | 13 | 1096.20 | 37 | 10.68 | 1972 | 779 | 3.18 / 1327.42 | 3 | 4 |
6 | 13 | 103.44 | 5 | 13.71 | 647 | 44 | 3.23 / 1327.46 | 3 | 8 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 34 | 13.74 | 654 | 306 | 0.31 / 1321.30 | 3 | 4 |
2 | 3 | 1046.32 | 1 | 12.29 | 1964 | 24 | 0.33 / 1321.32 | 3 | 3 |
3 | 12 | 1129.64 | 50 | 8.35 | 1978 | 826 | 1.16 / 1322.15 | 3 | 3 |
4 | 7 | 1132.28 | 25 | 10.46 | 2049 | 536 | 1.69 / 1322.68 | 3 | 3 |
5 | 13 | 1110.48 | 37 | 10.76 | 1991 | 793 | 2.48 / 1323.48 | 3 | 4 |
6 | 13 | 856.76 | 37 | 12.60 | 1629 | 759 | 3.24 / 1324.23 | 3 | 7 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 34 | 13.76 | 646 | 302 | 0.30 / 1318.11 | 3 | 5 |
2 | 12 | 1136.20 | 50 | 9.30 | 2031 | 944 | 1.25 / 1319.05 | 3 | 3 |
3 | 7 | 1138.16 | 25 | 10.70 | 2071 | 554 | 1.80 / 1319.61 | 3 | 3 |
4 | 13 | 1109.52 | 37 | 11.11 | 1999 | 822 | 2.62 / 1320.43 | 3 | 4 |
5 | 13 | 508.68 | 37 | 13.30 | 1145 | 563 | 3.19 / 1320.99 | 3 | 10 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 34 | 13.68 | 655 | 305 | 0.30 / 1313.36 | 3 | 5 |
2 | 3 | 957.28 | -1 | 13.68 | 655 | 0 | 0.00 / 1313.36 | 3 | 5 |
3 | 12 | 1110.68 | 5 | 11.65 | 2085 | 121 | 0.43 / 1313.48 | 3 | 3 |
4 | 12 | 2009.68 | 50 | 10.18 | 3253 | 1656 | 2.08 / 1315.14 | 3 | 3 |
5 | 7 | 2005.76 | 25 | 10.35 | 3262 | 844 | 2.93 / 1315.98 | 3 | 3 |
6 | 13 | 1704.52 | 37 | 11.87 | 2836 | 1246 | 4.17 / 1317.23 | 3 | 4 |
7 | 13 | 524.84 | 37 | 13.34 | 1172 | 578 | 4.75 / 1317.81 | 3 | 11 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 33 | 13.73 | 665 | 301 | 0.30 / 1310.22 | 3 | 5 |
2 | 12 | 1112.96 | 50 | 7.39 | 1967 | 727 | 1.03 / 1310.94 | 3 | 3 |
3 | 7 | 1116.20 | 25 | 10.47 | 2061 | 539 | 1.57 / 1311.48 | 3 | 3 |
4 | 13 | 1104.48 | 37 | 10.79 | 2002 | 799 | 2.37 / 1312.28 | 3 | 4 |
5 | 13 | 902.76 | 37 | 12.45 | 1680 | 774 | 3.14 / 1313.06 | 3 | 7 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 35 | 13.71 | 675 | 324 | 0.32 / 1307.03 | 3 | 6 |
2 | 3 | 976.28 | -1 | 13.71 | 675 | 0 | 0.00 / 1307.03 | 3 | 6 |
3 | 12 | 1146.40 | 50 | 8.15 | 1980 | 807 | 1.13 / 1307.83 | 3 | 3 |
4 | 7 | 1148.88 | 25 | 10.58 | 2083 | 551 | 1.68 / 1308.38 | 3 | 3 |
5 | 13 | 1128.12 | 37 | 11.01 | 2003 | 816 | 2.50 / 1309.20 | 3 | 4 |
6 | 13 | 753.20 | 37 | 12.89 | 1501 | 716 | 3.21 / 1309.92 | 3 | 9 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 34 | 13.75 | 659 | 308 | 0.31 / 1303.78 | 3 | 5 |
2 | 12 | 1137.56 | 50 | 9.30 | 2039 | 948 | 1.26 / 1304.73 | 3 | 3 |
3 | 7 | 1139.40 | 25 | 10.76 | 2083 | 560 | 1.82 / 1305.29 | 3 | 3 |
4 | 13 | 1109.76 | 37 | 11.29 | 1987 | 830 | 2.65 / 1306.12 | 3 | 4 |
5 | 13 | 525.76 | 37 | 13.31 | 1187 | 585 | 3.23 / 1306.70 | 3 | 10 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 35 | 13.66 | 663 | 317 | 0.32 / 1299.14 | 3 | 5 |
2 | 3 | 949.80 | -1 | 13.66 | 663 | 0 | 0.00 / 1299.14 | 3 | 5 |
3 | 12 | 1137.60 | 5 | 11.60 | 2118 | 123 | 0.44 / 1299.27 | 3 | 3 |
4 | 12 | 2002.92 | 50 | 10.27 | 3242 | 1665 | 2.10 / 1300.93 | 3 | 3 |
5 | 7 | 1999.44 | 25 | 10.40 | 3235 | 841 | 2.95 / 1301.77 | 3 | 3 |
6 | 13 | 1552.76 | 37 | 12.14 | 2602 | 1169 | 4.11 / 1302.94 | 3 | 5 |
7 | 13 | 450.08 | 37 | 13.47 | 1060 | 528 | 4.64 / 1303.47 | 3 | 10 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 33 | 13.72 | 660 | 299 | 0.30 / 1295.86 | 3 | 5 |
2 | 12 | 1133.12 | 50 | 7.17 | 1948 | 698 | 1.00 / 1296.56 | 3 | 3 |
3 | 7 | 1136.24 | 25 | 10.52 | 2069 | 544 | 1.54 / 1297.10 | 3 | 3 |
4 | 13 | 1124.88 | 37 | 10.97 | 2009 | 815 | 2.36 / 1297.91 | 3 | 4 |
5 | 13 | 1005.92 | 37 | 12.24 | 1833 | 830 | 3.19 / 1298.74 | 3 | 6 |
6 | 13 | 56.72 | 5 | 13.80 | 602 | 42 | 3.23 / 1298.79 | 3 | 7 |
7 | 13 | 40.52 | 5 | 13.82 | 597 | 41 | 3.27 / 1298.83 | 3 | 7 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 34 | 13.73 | 662 | 309 | 0.31 / 1292.69 | 3 | 5 |
2 | 12 | 1132.52 | 50 | 8.14 | 1962 | 799 | 1.11 / 1293.48 | 3 | 3 |
3 | 7 | 1135.56 | 25 | 10.62 | 2068 | 549 | 1.66 / 1294.03 | 3 | 3 |
4 | 13 | 1118.64 | 37 | 11.20 | 1989 | 824 | 2.48 / 1294.86 | 3 | 4 |
5 | 13 | 745.96 | 37 | 12.94 | 1462 | 700 | 3.18 / 1295.56 | 3 | 8 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 35 | 13.71 | 663 | 318 | 0.32 / 1289.49 | 3 | 6 |
2 | 3 | 952.96 | -1 | 13.71 | 663 | 0 | 0.00 / 1289.49 | 3 | 6 |
3 | 12 | 1138.72 | 50 | 9.21 | 2003 | 922 | 1.24 / 1290.42 | 3 | 3 |
4 | 7 | 1140.60 | 25 | 10.79 | 2080 | 561 | 1.80 / 1290.98 | 3 | 3 |
5 | 13 | 1113.84 | 37 | 11.40 | 2004 | 845 | 2.65 / 1291.82 | 3 | 4 |
6 | 13 | 482.96 | 37 | 13.38 | 1122 | 555 | 3.20 / 1292.38 | 3 | 11 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 33 | 13.75 | 649 | 294 | 0.29 / 1284.66 | 3 | 5 |
2 | 3 | 1044.84 | 1 | 12.15 | 1955 | 24 | 0.32 / 1284.68 | 3 | 3 |
3 | 12 | 1108.68 | 5 | 11.64 | 2066 | 120 | 0.44 / 1284.80 | 3 | 3 |
4 | 12 | 2002.92 | 50 | 10.31 | 3250 | 1675 | 2.11 / 1286.47 | 3 | 3 |
5 | 7 | 1998.96 | 25 | 10.47 | 3238 | 848 | 2.96 / 1287.32 | 3 | 3 |
6 | 13 | 1740.40 | 37 | 11.93 | 2886 | 1274 | 4.24 / 1288.60 | 3 | 4 |
7 | 13 | 504.48 | 37 | 13.41 | 1166 | 579 | 4.81 / 1289.17 | 3 | 11 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 34 | 13.71 | 666 | 310 | 0.31 / 1281.26 | 3 | 5 |
2 | 3 | 978.04 | -1 | 13.71 | 666 | 0 | 0.00 / 1281.26 | 3 | 5 |
3 | 12 | 1133.68 | 50 | 7.02 | 1971 | 692 | 1.00 / 1281.95 | 3 | 3 |
4 | 7 | 1136.84 | 25 | 10.57 | 2071 | 547 | 1.55 / 1282.50 | 3 | 3 |
5 | 13 | 1127.68 | 37 | 11.12 | 2021 | 832 | 2.38 / 1283.33 | 3 | 4 |
6 | 13 | 1007.52 | 37 | 12.29 | 1860 | 846 | 3.23 / 1284.18 | 3 | 6 |
7 | 13 | 298.84 | 6 | 13.66 | 915 | 75 | 3.30 / 1284.25 | 3 | 10 |
8 | 13 | 260.04 | 5 | 13.71 | 865 | 59 | 3.36 / 1284.31 | 3 | 10 |
9 | 13 | 135.00 | 5 | 13.81 | 697 | 48 | 3.41 / 1284.36 | 3 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 35 | 13.74 | 644 | 310 | 0.31 / 1278.02 | 3 | 5 |
2 | 12 | 1137.40 | 50 | 7.97 | 1973 | 786 | 1.10 / 1278.80 | 3 | 3 |
3 | 7 | 1140.24 | 25 | 10.70 | 2066 | 553 | 1.65 / 1279.36 | 3 | 3 |
4 | 13 | 1121.48 | 37 | 11.36 | 1999 | 840 | 2.49 / 1280.20 | 3 | 4 |
5 | 13 | 826.76 | 37 | 12.83 | 1590 | 755 | 3.24 / 1280.95 | 3 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 35 | 13.71 | 665 | 319 | 0.32 / 1274.80 | 3 | 5 |
2 | 12 | 1132.68 | 50 | 9.22 | 2020 | 931 | 1.25 / 1275.73 | 3 | 3 |
3 | 7 | 1134.68 | 25 | 10.85 | 2071 | 562 | 1.81 / 1276.29 | 3 | 3 |
4 | 13 | 1107.60 | 37 | 11.49 | 2016 | 857 | 2.67 / 1277.15 | 3 | 5 |
5 | 13 | 488.24 | 37 | 13.39 | 1131 | 560 | 3.23 / 1277.71 | 3 | 11 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 33 | 13.71 | 670 | 303 | 0.30 / 1270.01 | 3 | 5 |
2 | 12 | 1129.04 | 5 | 11.61 | 2088 | 121 | 0.42 / 1270.13 | 3 | 3 |
3 | 12 | 2000.52 | 50 | 10.29 | 3240 | 1667 | 2.09 / 1271.80 | 3 | 3 |
4 | 7 | 1996.72 | 25 | 10.44 | 3232 | 844 | 2.93 / 1272.64 | 3 | 3 |
5 | 13 | 1568.28 | 37 | 12.18 | 2648 | 1193 | 4.13 / 1273.83 | 3 | 5 |
6 | 13 | 613.20 | 37 | 13.31 | 1307 | 644 | 4.77 / 1274.48 | 3 | 11 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 33 | 13.74 | 633 | 287 | 0.29 / 1266.76 | 3 | 4 |
2 | 12 | 1136.68 | 50 | 6.97 | 2001 | 697 | 0.98 / 1267.45 | 3 | 3 |
3 | 7 | 1140.00 | 25 | 10.61 | 2090 | 554 | 1.54 / 1268.01 | 3 | 3 |
4 | 13 | 1131.48 | 37 | 11.32 | 2023 | 847 | 2.39 / 1268.85 | 3 | 4 |
5 | 13 | 929.96 | 37 | 12.61 | 1733 | 809 | 3.19 / 1269.66 | 3 | 7 |
6 | 13 | 85.40 | 5 | 13.87 | 623 | 43 | 3.24 / 1269.71 | 3 | 8 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 34 | 13.76 | 662 | 310 | 0.31 / 1263.52 | 3 | 5 |
2 | 3 | 1025.24 | 1 | 12.02 | 1965 | 24 | 0.33 / 1263.54 | 3 | 3 |
3 | 12 | 1146.36 | 50 | 8.20 | 2003 | 821 | 1.15 / 1264.36 | 3 | 3 |
4 | 7 | 1149.04 | 25 | 10.81 | 2080 | 562 | 1.72 / 1264.92 | 3 | 3 |
5 | 13 | 1129.16 | 37 | 11.50 | 2012 | 856 | 2.57 / 1265.78 | 3 | 4 |
6 | 13 | 696.80 | 37 | 13.11 | 1418 | 688 | 3.26 / 1266.47 | 3 | 10 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 35 | 13.73 | 653 | 314 | 0.31 / 1260.26 | 3 | 6 |
2 | 3 | 976.40 | -1 | 13.73 | 653 | 0 | 0.00 / 1260.26 | 3 | 6 |
3 | 12 | 1138.52 | 50 | 9.43 | 2015 | 950 | 1.26 / 1261.21 | 3 | 3 |
4 | 7 | 1140.52 | 25 | 10.91 | 2061 | 562 | 1.83 / 1261.77 | 3 | 3 |
5 | 13 | 1112.48 | 37 | 11.67 | 1990 | 859 | 2.69 / 1262.63 | 3 | 5 |
6 | 13 | 526.28 | 37 | 13.38 | 1167 | 578 | 3.26 / 1263.21 | 3 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 34 | 13.71 | 668 | 311 | 0.31 / 1255.55 | 3 | 5 |
2 | 3 | 973.32 | -1 | 13.71 | 668 | 0 | 0.00 / 1255.55 | 3 | 5 |
3 | 12 | 1135.92 | 5 | 11.76 | 2105 | 124 | 0.44 / 1255.68 | 3 | 3 |
4 | 12 | 2001.36 | 50 | 10.39 | 3246 | 1686 | 2.12 / 1257.36 | 3 | 3 |
5 | 7 | 1997.32 | 25 | 10.51 | 3234 | 850 | 2.97 / 1258.21 | 3 | 3 |
6 | 13 | 1478.28 | 37 | 12.33 | 2518 | 1149 | 4.12 / 1259.36 | 3 | 5 |
7 | 13 | 521.08 | 37 | 13.43 | 1178 | 585 | 4.71 / 1259.95 | 3 | 11 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 35 | 13.72 | 659 | 316 | 0.32 / 1252.16 | 3 | 5 |
2 | 3 | 937.24 | -2 | 13.72 | 659 | 0 | 0.00 / 1252.16 | 3 | 5 |
3 | 12 | 1140.12 | 50 | 7.06 | 1954 | 690 | 1.01 / 1252.85 | 3 | 3 |
4 | 7 | 1143.96 | 25 | 10.58 | 2100 | 555 | 1.56 / 1253.41 | 3 | 3 |
5 | 13 | 1139.20 | 37 | 11.36 | 2049 | 861 | 2.42 / 1254.27 | 3 | 4 |
6 | 13 | 1101.52 | 37 | 11.56 | 1965 | 840 | 3.26 / 1255.11 | 3 | 5 |
7 | 13 | 117.72 | 5 | 13.84 | 670 | 46 | 3.31 / 1255.16 | 3 | 8 |
8 | 13 | 48.24 | 5 | 13.87 | 606 | 42 | 3.35 / 1255.20 | 3 | 7 |
9 | 13 | 43.92 | 5 | 13.82 | 594 | 41 | 3.39 / 1255.24 | 3 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 35 | 13.74 | 662 | 318 | 0.32 / 1248.90 | 3 | 5 |
2 | 3 | 979.88 | -1 | 13.74 | 662 | 0 | 0.00 / 1248.90 | 3 | 5 |
3 | 3 | 1020.20 | 1 | 11.62 | 1984 | 23 | 0.34 / 1248.92 | 3 | 3 |
4 | 12 | 1150.88 | 50 | 8.04 | 1990 | 800 | 1.14 / 1249.72 | 3 | 3 |
5 | 7 | 1153.84 | 25 | 10.76 | 2100 | 565 | 1.71 / 1250.29 | 3 | 3 |
6 | 13 | 1135.64 | 37 | 11.61 | 1999 | 859 | 2.57 / 1251.14 | 3 | 4 |
7 | 13 | 724.64 | 37 | 13.09 | 1452 | 703 | 3.27 / 1251.85 | 3 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 33 | 13.73 | 651 | 295 | 0.29 / 1245.58 | 3 | 5 |
2 | 3 | 1061.36 | 2 | 12.61 | 2008 | 51 | 0.35 / 1245.63 | 3 | 3 |
3 | 3 | 1018.84 | 1 | 12.05 | 1952 | 24 | 0.37 / 1245.65 | 3 | 3 |
4 | 12 | 1139.40 | 50 | 9.18 | 2020 | 927 | 1.30 / 1246.58 | 3 | 3 |
5 | 7 | 1141.24 | 25 | 10.89 | 2090 | 569 | 1.87 / 1247.15 | 3 | 3 |
6 | 13 | 1112.12 | 37 | 11.70 | 2001 | 866 | 2.73 / 1248.01 | 3 | 5 |
7 | 13 | 490.12 | 37 | 13.40 | 1141 | 566 | 3.30 / 1248.58 | 3 | 11 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 35 | 13.70 | 673 | 323 | 0.32 / 1240.89 | 3 | 6 |
2 | 3 | 946.32 | -1 | 13.70 | 673 | 0 | 0.00 / 1240.89 | 3 | 6 |
3 | 12 | 1104.92 | 5 | 11.64 | 2063 | 120 | 0.44 / 1241.01 | 3 | 3 |
4 | 12 | 2009.52 | 50 | 10.26 | 3255 | 1670 | 2.11 / 1242.68 | 3 | 3 |
5 | 7 | 2005.64 | 25 | 10.45 | 3244 | 847 | 2.96 / 1243.53 | 3 | 3 |
6 | 13 | 1533.16 | 37 | 12.27 | 2592 | 1177 | 4.14 / 1244.71 | 3 | 5 |
7 | 13 | 520.20 | 37 | 13.43 | 1160 | 576 | 4.71 / 1245.28 | 3 | 11 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 35 | 13.71 | 661 | 317 | 0.32 / 1237.68 | 3 | 5 |
2 | 12 | 1135.12 | 50 | 8.03 | 1979 | 795 | 1.11 / 1238.48 | 3 | 3 |
3 | 7 | 1138.24 | 25 | 10.76 | 2082 | 560 | 1.67 / 1239.04 | 3 | 3 |
4 | 13 | 1122.12 | 37 | 11.63 | 1987 | 855 | 2.53 / 1239.89 | 3 | 4 |
5 | 13 | 658.84 | 37 | 13.16 | 1386 | 675 | 3.20 / 1240.57 | 3 | 10 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 34 | 13.73 | 660 | 308 | 0.31 / 1234.52 | 3 | 6 |
2 | 3 | 954.04 | -1 | 13.73 | 660 | 0 | 0.00 / 1234.52 | 3 | 6 |
3 | 12 | 1115.32 | 50 | 8.81 | 1934 | 852 | 1.16 / 1235.37 | 3 | 3 |
4 | 7 | 1117.52 | 25 | 10.94 | 2041 | 558 | 1.72 / 1235.93 | 3 | 3 |
5 | 13 | 1092.64 | 37 | 11.78 | 1965 | 856 | 2.57 / 1236.79 | 3 | 5 |
6 | 13 | 523.48 | 37 | 13.37 | 1172 | 580 | 3.15 / 1237.37 | 3 | 10 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 34 | 13.73 | 656 | 306 | 0.31 / 1231.55 | 3 | 5 |
2 | 12 | 1139.24 | 50 | 9.52 | 1987 | 946 | 1.25 / 1232.50 | 3 | 3 |
3 | 7 | 1140.52 | 25 | 10.99 | 2057 | 565 | 1.82 / 1233.07 | 3 | 4 |
4 | 13 | 1109.72 | 37 | 11.83 | 1987 | 870 | 2.69 / 1233.94 | 3 | 5 |
5 | 13 | 351.92 | 7 | 13.75 | 970 | 93 | 2.78 / 1234.03 | 3 | 10 |
6 | 13 | 228.84 | 5 | 13.82 | 810 | 56 | 2.84 / 1234.08 | 3 | 10 |
7 | 13 | 109.76 | 5 | 13.91 | 663 | 46 | 2.88 / 1234.13 | 3 | 8 |
8 | 13 | 46.72 | 5 | 13.93 | 583 | 41 | 2.92 / 1234.17 | 3 | 7 |
9 | 13 | 43.44 | 5 | 13.90 | 586 | 41 | 2.96 / 1234.21 | 3 | 7 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 36 | 13.70 | 654 | 323 | 0.32 / 1226.82 | 3 | 5 |
2 | 3 | 956.44 | -1 | 13.70 | 654 | 0 | 0.00 / 1226.82 | 3 | 5 |
3 | 12 | 1112.72 | 5 | 11.75 | 2082 | 122 | 0.44 / 1226.94 | 3 | 3 |
4 | 12 | 2008.12 | 50 | 10.46 | 3239 | 1694 | 2.14 / 1228.63 | 3 | 3 |
5 | 7 | 2003.92 | 25 | 10.60 | 3243 | 859 | 3.00 / 1229.49 | 3 | 3 |
6 | 13 | 1526.08 | 37 | 12.39 | 2564 | 1175 | 4.17 / 1230.67 | 3 | 5 |
7 | 13 | 514.88 | 37 | 13.46 | 1164 | 580 | 4.75 / 1231.25 | 3 | 11 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 43 | 13.61 | 667 | 390 | 0.39 / 1223.54 | 3 | 7 |
2 | 3 | 760.36 | -6 | 13.61 | 667 | 0 | 0.00 / 1223.54 | 3 | 7 |
3 | 3 | 939.32 | -2 | 13.61 | 667 | 0 | 0.00 / 1223.54 | 3 | 7 |
4 | 12 | 1143.56 | 50 | 8.16 | 1948 | 795 | 1.19 / 1224.34 | 3 | 3 |
5 | 7 | 1146.16 | 25 | 10.88 | 2082 | 566 | 1.75 / 1224.91 | 3 | 3 |
6 | 13 | 1125.68 | 37 | 11.77 | 2027 | 883 | 2.63 / 1225.79 | 3 | 5 |
7 | 13 | 711.40 | 37 | 13.16 | 1451 | 707 | 3.34 / 1226.50 | 3 | 10 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 33 | 13.71 | 662 | 300 | 0.30 / 1220.19 | 3 | 5 |
2 | 3 | 1019.56 | 1 | 12.11 | 1938 | 23 | 0.32 / 1220.21 | 3 | 3 |
3 | 12 | 1148.68 | 50 | 8.94 | 1999 | 894 | 1.22 / 1221.11 | 3 | 3 |
4 | 7 | 1150.92 | 25 | 11.00 | 2079 | 572 | 1.79 / 1221.68 | 3 | 3 |
5 | 13 | 1126.88 | 37 | 11.84 | 2040 | 894 | 2.68 / 1222.57 | 3 | 5 |
6 | 13 | 518.44 | 37 | 13.40 | 1171 | 581 | 3.26 / 1223.15 | 3 | 11 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 43 | 13.63 | 672 | 394 | 0.39 / 1217.17 | 3 | 7 |
2 | 3 | 682.16 | -8 | 13.63 | 672 | 0 | 0.00 / 1217.17 | 3 | 7 |
3 | 3 | 912.12 | -2 | 13.63 | 672 | 0 | 0.00 / 1217.17 | 3 | 7 |
4 | 12 | 1106.40 | 50 | 9.76 | 1968 | 960 | 1.35 / 1218.13 | 3 | 3 |
5 | 7 | 1107.52 | 25 | 11.17 | 1999 | 558 | 1.91 / 1218.69 | 3 | 4 |
6 | 13 | 1074.20 | 37 | 12.10 | 1919 | 859 | 2.77 / 1219.55 | 3 | 6 |
7 | 13 | 311.08 | 6 | 13.78 | 934 | 77 | 2.85 / 1219.62 | 3 | 10 |
8 | 13 | 190.60 | 5 | 13.86 | 767 | 53 | 2.90 / 1219.68 | 3 | 8 |
9 | 13 | 151.20 | 5 | 13.88 | 728 | 51 | 2.95 / 1219.73 | 3 | 9 |
10 | 13 | 55.16 | 5 | 13.93 | 606 | 42 | 2.99 / 1219.77 | 3 | 7 |
11 | 13 | 48.00 | 5 | 13.91 | 600 | 42 | 3.04 / 1219.81 | 3 | 7 |
12 | 13 | 44.08 | 5 | 13.90 | 583 | 41 | 3.08 / 1219.85 | 3 | 7 |
13 | 13 | 41.20 | 5 | 13.87 | 590 | 41 | 3.12 / 1219.89 | 3 | 7 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 43 | 13.64 | 661 | 388 | 0.39 / 1212.67 | 3 | 7 |
2 | 3 | 773.16 | -6 | 13.64 | 661 | 0 | 0.00 / 1212.67 | 3 | 7 |
3 | 3 | 954.20 | -1 | 13.64 | 661 | 0 | 0.00 / 1212.67 | 3 | 7 |
4 | 12 | 1111.12 | 5 | 11.96 | 2066 | 124 | 0.51 / 1212.79 | 3 | 3 |
5 | 12 | 2009.04 | 50 | 10.71 | 3238 | 1734 | 2.25 / 1214.52 | 3 | 3 |
6 | 7 | 2004.92 | 25 | 10.71 | 3249 | 870 | 3.12 / 1215.39 | 3 | 3 |
7 | 13 | 1436.84 | 37 | 12.54 | 2474 | 1148 | 4.26 / 1216.54 | 3 | 6 |
8 | 13 | 344.36 | 7 | 13.81 | 971 | 94 | 4.36 / 1216.63 | 3 | 10 |
9 | 13 | 138.08 | 5 | 13.91 | 713 | 50 | 4.41 / 1216.68 | 3 | 9 |
10 | 13 | 99.88 | 5 | 13.95 | 663 | 46 | 4.45 / 1216.73 | 3 | 8 |
11 | 13 | 68.12 | 5 | 13.94 | 626 | 44 | 4.50 / 1216.77 | 3 | 7 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 34 | 13.69 | 670 | 312 | 0.31 / 1209.18 | 3 | 3 |
2 | 10 | 1009.36 | 5 | 13.11 | 1886 | 124 | 0.44 / 1209.30 | 3 | 4 |
3 | 10 | 1042.28 | 3 | 13.24 | 1954 | 78 | 0.51 / 1209.38 | 3 | 4 |
4 | 3 | 1023.44 | 1 | 12.28 | 1942 | 24 | 0.54 / 1209.40 | 3 | 3 |
5 | 12 | 1143.04 | 50 | 9.28 | 1968 | 913 | 1.45 / 1210.32 | 3 | 3 |
6 | 7 | 1144.68 | 25 | 11.04 | 2063 | 569 | 2.02 / 1210.89 | 3 | 4 |
7 | 13 | 1116.28 | 37 | 11.99 | 1971 | 874 | 2.89 / 1211.76 | 3 | 5 |
8 | 13 | 417.28 | 37 | 13.54 | 1033 | 518 | 3.41 / 1212.28 | 3 | 10 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 42 | 13.64 | 641 | 367 | 0.37 / 1204.64 | 3 | 5 |
2 | 3 | 1031.00 | 1 | 12.40 | 1959 | 24 | 0.39 / 1204.66 | 3 | 3 |
3 | 12 | 1151.64 | 50 | 9.62 | 2004 | 964 | 1.36 / 1205.63 | 3 | 3 |
4 | 7 | 1153.12 | 25 | 11.05 | 2081 | 575 | 1.93 / 1206.20 | 3 | 4 |
5 | 13 | 1124.96 | 37 | 12.01 | 1988 | 883 | 2.81 / 1207.08 | 3 | 5 |
6 | 13 | 362.32 | 37 | 13.61 | 940 | 473 | 3.29 / 1207.56 | 3 | 10 |
7 | 8 | 0.48 | 190 | 13.51 | 510 | 1309 | 4.60 / 1208.87 | 3 | 10 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 32 | 13.67 | 686 | 300 | 0.30 / 1199.82 | 3 | 4 |
2 | 10 | 1046.84 | 5 | 13.17 | 1942 | 128 | 0.43 / 1199.94 | 3 | 3 |
3 | 10 | 1076.52 | 3 | 13.25 | 2056 | 82 | 0.51 / 1200.03 | 3 | 4 |
4 | 3 | 1055.88 | 1 | 12.82 | 2001 | 26 | 0.54 / 1200.05 | 3 | 3 |
5 | 12 | 1149.20 | 50 | 10.13 | 2014 | 1020 | 1.56 / 1201.07 | 3 | 3 |
6 | 7 | 1150.12 | 25 | 11.26 | 2082 | 586 | 2.14 / 1201.66 | 3 | 4 |
7 | 13 | 1116.60 | 37 | 12.21 | 2003 | 905 | 3.05 / 1202.56 | 3 | 6 |
8 | 13 | 238.16 | 37 | 13.76 | 784 | 399 | 3.45 / 1202.96 | 3 | 9 |
9 | 8 | 0.44 | 190 | 13.51 | 510 | 1309 | 4.75 / 1204.27 | 3 | 9 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 43 | 13.55 | 665 | 387 | 0.39 / 1193.75 | 3 | 8 |
2 | 12 | 1107.56 | 5 | 12.30 | 2072 | 127 | 0.51 / 1193.88 | 3 | 3 |
3 | 12 | 2001.16 | 50 | 11.10 | 3230 | 1793 | 2.31 / 1195.68 | 3 | 3 |
4 | 7 | 1996.40 | 25 | 10.90 | 3233 | 881 | 3.19 / 1196.56 | 3 | 3 |
5 | 13 | 1405.68 | 37 | 12.63 | 2415 | 1129 | 4.32 / 1197.68 | 3 | 6 |
6 | 13 | 382.96 | 37 | 13.59 | 1004 | 505 | 4.82 / 1198.19 | 3 | 12 |
7 | 8 | 0.20 | 190 | 13.50 | 517 | 1326 | 6.15 / 1199.52 | 3 | 9 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 42 | 13.56 | 668 | 380 | 0.38 / 1187.57 | 3 | 9 |
2 | 12 | 1130.80 | 5 | 12.26 | 2118 | 130 | 0.51 / 1187.70 | 3 | 3 |
3 | 12 | 1999.12 | 50 | 10.98 | 3230 | 1773 | 2.28 / 1189.47 | 3 | 3 |
4 | 7 | 1994.40 | 25 | 10.86 | 3217 | 873 | 3.16 / 1190.34 | 3 | 3 |
5 | 13 | 1671.44 | 37 | 12.34 | 2775 | 1267 | 4.42 / 1191.61 | 3 | 5 |
6 | 13 | 336.56 | 37 | 13.64 | 901 | 455 | 4.88 / 1192.07 | 3 | 10 |
7 | 8 | 0.24 | 190 | 13.52 | 507 | 1302 | 6.18 / 1193.37 | 3 | 9 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 32 | 13.64 | 631 | 275 | 0.28 / 1181.35 | 3 | 3 |
2 | 10 | 1015.00 | 5 | 13.01 | 1889 | 123 | 0.40 / 1181.47 | 3 | 3 |
3 | 10 | 1046.64 | 3 | 13.12 | 1988 | 78 | 0.48 / 1181.55 | 3 | 4 |
4 | 3 | 1057.72 | 1 | 12.25 | 1987 | 24 | 0.50 / 1181.57 | 3 | 3 |
5 | 3 | 1029.60 | 1 | 11.72 | 1924 | 23 | 0.52 / 1181.60 | 3 | 3 |
6 | 12 | 1142.16 | 5 | 11.85 | 2124 | 126 | 0.65 / 1181.72 | 3 | 3 |
7 | 12 | 2012.12 | 50 | 10.48 | 3240 | 1698 | 2.35 / 1183.42 | 3 | 3 |
8 | 7 | 2008.64 | 25 | 10.63 | 3224 | 857 | 3.20 / 1184.28 | 3 | 3 |
9 | 13 | 1459.48 | 37 | 12.45 | 2451 | 1129 | 4.33 / 1185.41 | 3 | 5 |
10 | 13 | 370.92 | 37 | 13.57 | 960 | 482 | 4.81 / 1185.89 | 3 | 10 |
11 | 8 | 0.44 | 190 | 13.51 | 506 | 1299 | 6.11 / 1187.19 | 3 | 10 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 34 | 13.70 | 636 | 296 | 0.30 / 1176.69 | 3 | 5 |
2 | 12 | 1114.64 | 50 | 7.33 | 1891 | 693 | 0.99 / 1177.39 | 3 | 3 |
3 | 7 | 1117.96 | 25 | 10.47 | 2027 | 531 | 1.52 / 1177.92 | 3 | 3 |
4 | 13 | 1076.44 | 37 | 12.13 | 1961 | 880 | 2.40 / 1178.80 | 3 | 6 |
5 | 13 | 810.12 | 37 | 12.89 | 1552 | 740 | 3.14 / 1179.54 | 3 | 8 |
6 | 13 | 15.24 | 37 | 13.83 | 532 | 272 | 3.41 / 1179.81 | 3 | 7 |
7 | 8 | 0.44 | 190 | 13.42 | 495 | 1262 | 4.67 / 1181.07 | 3 | 12 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 34 | 13.68 | 663 | 308 | 0.31 / 1173.63 | 3 | 7 |
2 | 3 | 939.08 | -2 | 13.68 | 663 | 0 | 0.00 / 1173.63 | 3 | 7 |
3 | 12 | 1137.52 | 50 | 8.01 | 1919 | 769 | 1.08 / 1174.40 | 3 | 3 |
4 | 7 | 1139.96 | 25 | 10.69 | 2063 | 551 | 1.63 / 1174.95 | 3 | 3 |
5 | 13 | 1069.64 | 37 | 12.32 | 1917 | 874 | 2.50 / 1175.82 | 3 | 5 |
6 | 13 | 521.72 | 37 | 13.33 | 1164 | 574 | 3.08 / 1176.40 | 3 | 10 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 33 | 13.67 | 655 | 295 | 0.30 / 1170.71 | 3 | 5 |
2 | 3 | 1036.32 | 1 | 12.14 | 1961 | 24 | 0.32 / 1170.73 | 3 | 3 |
3 | 12 | 1138.04 | 50 | 9.10 | 1971 | 897 | 1.22 / 1171.63 | 3 | 3 |
4 | 7 | 1139.92 | 25 | 10.90 | 2061 | 562 | 1.78 / 1172.19 | 3 | 3 |
5 | 13 | 1044.80 | 37 | 12.54 | 1869 | 867 | 2.64 / 1173.06 | 3 | 6 |
6 | 13 | 351.84 | 7 | 13.69 | 962 | 92 | 2.74 / 1173.15 | 3 | 10 |
7 | 13 | 130.68 | 5 | 13.83 | 683 | 47 | 2.78 / 1173.20 | 3 | 8 |
8 | 13 | 85.80 | 5 | 13.85 | 638 | 44 | 2.83 / 1173.24 | 3 | 8 |
9 | 13 | 61.28 | 5 | 13.88 | 606 | 42 | 2.87 / 1173.28 | 3 | 8 |
10 | 13 | 41.00 | 5 | 13.87 | 585 | 41 | 2.91 / 1173.32 | 3 | 8 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 33 | 13.66 | 650 | 293 | 0.29 / 1166.13 | 3 | 5 |
2 | 3 | 972.80 | -1 | 13.66 | 650 | 0 | 0.00 / 1166.13 | 3 | 5 |
3 | 12 | 1132.64 | 5 | 11.51 | 2083 | 120 | 0.41 / 1166.25 | 3 | 3 |
4 | 12 | 2001.60 | 50 | 10.05 | 3218 | 1617 | 2.03 / 1167.87 | 3 | 3 |
5 | 7 | 1997.68 | 25 | 10.45 | 3221 | 841 | 2.87 / 1168.71 | 3 | 3 |
6 | 13 | 1446.68 | 37 | 12.39 | 2454 | 1125 | 4.00 / 1169.83 | 3 | 5 |
7 | 13 | 529.40 | 37 | 13.40 | 1168 | 579 | 4.58 / 1170.41 | 3 | 10 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 33 | 13.62 | 675 | 303 | 0.30 / 1162.95 | 3 | 6 |
2 | 12 | 1139.04 | 50 | 7.45 | 1896 | 706 | 1.01 / 1163.65 | 3 | 3 |
3 | 7 | 1142.20 | 25 | 10.56 | 2034 | 537 | 1.55 / 1164.19 | 3 | 3 |
4 | 13 | 1090.24 | 37 | 12.18 | 1979 | 892 | 2.44 / 1165.08 | 3 | 5 |
5 | 13 | 818.56 | 37 | 12.92 | 1575 | 753 | 3.19 / 1165.84 | 3 | 8 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 35 | 13.64 | 647 | 309 | 0.31 / 1159.88 | 3 | 6 |
2 | 3 | 924.32 | -2 | 13.64 | 647 | 0 | 0.00 / 1159.88 | 3 | 6 |
3 | 12 | 1123.48 | 50 | 8.14 | 1926 | 784 | 1.09 / 1160.67 | 3 | 3 |
4 | 7 | 1126.40 | 25 | 10.71 | 2033 | 544 | 1.64 / 1161.21 | 3 | 3 |
5 | 13 | 1057.36 | 37 | 12.40 | 1894 | 869 | 2.51 / 1162.08 | 3 | 6 |
6 | 13 | 497.48 | 37 | 13.33 | 1144 | 564 | 3.07 / 1162.64 | 3 | 11 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 33 | 13.66 | 651 | 293 | 0.29 / 1156.98 | 3 | 5 |
2 | 3 | 1044.96 | 1 | 12.24 | 1963 | 24 | 0.32 / 1157.00 | 3 | 3 |
3 | 12 | 1143.84 | 50 | 9.10 | 1984 | 903 | 1.22 / 1157.91 | 3 | 3 |
4 | 7 | 1146.00 | 25 | 10.92 | 2069 | 565 | 1.79 / 1158.47 | 3 | 3 |
5 | 13 | 1055.24 | 37 | 12.55 | 1895 | 880 | 2.66 / 1159.35 | 3 | 6 |
6 | 13 | 335.12 | 7 | 13.71 | 938 | 90 | 2.76 / 1159.44 | 3 | 10 |
7 | 13 | 121.56 | 5 | 13.85 | 677 | 47 | 2.80 / 1159.49 | 3 | 8 |
8 | 13 | 82.44 | 5 | 13.86 | 634 | 44 | 2.85 / 1159.53 | 3 | 8 |
9 | 13 | 43.64 | 5 | 13.88 | 590 | 41 | 2.89 / 1159.57 | 3 | 6 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 34 | 13.63 | 659 | 305 | 0.31 / 1152.37 | 3 | 6 |
2 | 3 | 979.88 | -1 | 13.63 | 659 | 0 | 0.00 / 1152.37 | 3 | 6 |
3 | 12 | 1137.64 | 5 | 11.68 | 2054 | 120 | 0.43 / 1152.49 | 3 | 3 |
4 | 12 | 2008.64 | 50 | 10.10 | 3232 | 1632 | 2.06 / 1154.13 | 3 | 3 |
5 | 7 | 2004.68 | 25 | 10.51 | 3225 | 847 | 2.90 / 1154.97 | 3 | 3 |
6 | 13 | 1452.40 | 37 | 12.39 | 2456 | 1126 | 4.03 / 1156.10 | 3 | 5 |
7 | 13 | 531.56 | 37 | 13.38 | 1185 | 587 | 4.62 / 1156.69 | 3 | 10 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 33 | 13.67 | 658 | 297 | 0.30 / 1149.24 | 3 | 6 |
2 | 12 | 1130.68 | 50 | 7.87 | 1898 | 747 | 1.04 / 1149.98 | 3 | 3 |
3 | 7 | 1133.68 | 25 | 10.59 | 2053 | 544 | 1.59 / 1150.53 | 3 | 3 |
4 | 13 | 1077.96 | 37 | 12.28 | 1938 | 881 | 2.47 / 1151.41 | 3 | 6 |
5 | 13 | 665.24 | 37 | 13.13 | 1363 | 662 | 3.13 / 1152.07 | 3 | 10 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 34 | 13.65 | 641 | 297 | 0.30 / 1146.37 | 3 | 6 |
2 | 3 | 960.80 | -1 | 13.65 | 641 | 0 | 0.00 / 1146.37 | 3 | 6 |
3 | 12 | 1124.52 | 50 | 8.51 | 1908 | 812 | 1.11 / 1147.18 | 3 | 3 |
4 | 7 | 1127.04 | 25 | 10.77 | 2040 | 549 | 1.66 / 1147.73 | 3 | 3 |
5 | 13 | 1052.76 | 37 | 12.40 | 1912 | 877 | 2.54 / 1148.61 | 3 | 6 |
6 | 13 | 366.24 | 8 | 13.65 | 994 | 109 | 2.64 / 1148.72 | 3 | 10 |
7 | 13 | 239.68 | 5 | 13.73 | 827 | 57 | 2.70 / 1148.77 | 3 | 10 |
8 | 13 | 86.16 | 5 | 13.83 | 629 | 43 | 2.74 / 1148.82 | 3 | 8 |
9 | 13 | 63.80 | 5 | 13.83 | 607 | 42 | 2.79 / 1148.86 | 3 | 7 |
10 | 13 | 51.60 | 5 | 13.84 | 593 | 41 | 2.83 / 1148.90 | 3 | 7 |
11 | 13 | 45.56 | 5 | 13.82 | 587 | 41 | 2.87 / 1148.94 | 3 | 6 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 34 | 13.66 | 664 | 308 | 0.31 / 1143.48 | 3 | 5 |
2 | 12 | 1143.00 | 50 | 9.29 | 1978 | 919 | 1.23 / 1144.40 | 3 | 3 |
3 | 7 | 1144.92 | 25 | 10.99 | 2066 | 568 | 1.79 / 1144.97 | 3 | 4 |
4 | 13 | 1051.72 | 37 | 12.61 | 1896 | 885 | 2.68 / 1145.85 | 3 | 7 |
5 | 13 | 317.20 | 7 | 13.72 | 924 | 89 | 2.77 / 1145.94 | 3 | 9 |
6 | 13 | 109.00 | 5 | 13.84 | 649 | 45 | 2.81 / 1145.98 | 3 | 8 |
7 | 13 | 87.56 | 5 | 13.86 | 638 | 44 | 2.86 / 1146.03 | 3 | 8 |
8 | 13 | 64.00 | 5 | 13.85 | 610 | 42 | 2.90 / 1146.07 | 3 | 7 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 34 | 13.64 | 655 | 304 | 0.30 / 1139.01 | 3 | 5 |
2 | 12 | 1122.28 | 5 | 11.71 | 2039 | 119 | 0.42 / 1139.13 | 3 | 3 |
3 | 12 | 2009.84 | 50 | 10.16 | 3223 | 1637 | 2.06 / 1140.77 | 3 | 3 |
4 | 7 | 2005.96 | 25 | 10.54 | 3215 | 847 | 2.91 / 1141.62 | 3 | 3 |
5 | 13 | 1312.04 | 37 | 12.57 | 2263 | 1052 | 3.96 / 1142.67 | 3 | 6 |
6 | 13 | 404.84 | 37 | 13.51 | 1005 | 502 | 4.46 / 1143.17 | 3 | 11 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 33 | 13.62 | 650 | 292 | 0.29 / 1135.90 | 3 | 5 |
2 | 12 | 1118.28 | 50 | 7.84 | 1880 | 737 | 1.03 / 1136.64 | 3 | 3 |
3 | 7 | 1121.00 | 25 | 10.66 | 2037 | 543 | 1.57 / 1137.18 | 3 | 3 |
4 | 13 | 1057.24 | 37 | 12.38 | 1885 | 863 | 2.44 / 1138.05 | 3 | 6 |
5 | 13 | 649.08 | 37 | 13.15 | 1362 | 663 | 3.10 / 1138.71 | 3 | 10 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 35 | 13.62 | 653 | 311 | 0.31 / 1133.12 | 3 | 6 |
2 | 3 | 957.40 | -1 | 13.62 | 653 | 0 | 0.00 / 1133.12 | 3 | 6 |
3 | 12 | 1125.32 | 50 | 8.57 | 1921 | 823 | 1.13 / 1133.94 | 3 | 3 |
4 | 7 | 1127.84 | 25 | 10.84 | 2041 | 553 | 1.69 / 1134.49 | 3 | 3 |
5 | 13 | 1050.60 | 37 | 12.46 | 1908 | 880 | 2.57 / 1135.37 | 3 | 6 |
6 | 13 | 345.68 | 7 | 13.66 | 970 | 93 | 2.66 / 1135.47 | 3 | 10 |
7 | 13 | 216.24 | 5 | 13.75 | 800 | 55 | 2.71 / 1135.52 | 3 | 9 |
8 | 13 | 125.04 | 5 | 13.79 | 695 | 48 | 2.76 / 1135.57 | 3 | 9 |
9 | 13 | 57.28 | 5 | 13.85 | 603 | 42 | 2.80 / 1135.61 | 3 | 7 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 32 | 13.71 | 626 | 275 | 0.27 / 1130.10 | 3 | 4 |
2 | 3 | 1080.04 | 2 | 12.53 | 2005 | 50 | 0.32 / 1130.15 | 3 | 3 |
3 | 3 | 1030.32 | 1 | 11.95 | 1938 | 23 | 0.35 / 1130.18 | 3 | 3 |
4 | 12 | 1147.96 | 50 | 9.37 | 1984 | 930 | 1.28 / 1131.11 | 3 | 3 |
5 | 7 | 1149.76 | 25 | 11.06 | 2042 | 565 | 1.84 / 1131.67 | 3 | 4 |
6 | 13 | 1054.12 | 37 | 12.62 | 1900 | 887 | 2.73 / 1132.56 | 3 | 7 |
7 | 13 | 312.32 | 6 | 13.72 | 926 | 76 | 2.81 / 1132.64 | 3 | 11 |
8 | 13 | 110.64 | 5 | 13.82 | 656 | 45 | 2.85 / 1132.68 | 3 | 8 |
9 | 13 | 75.60 | 5 | 13.87 | 622 | 43 | 2.89 / 1132.72 | 3 | 7 |
10 | 13 | 57.16 | 5 | 13.85 | 603 | 42 | 2.94 / 1132.77 | 3 | 7 |
11 | 13 | 40.36 | 5 | 13.87 | 587 | 41 | 2.98 / 1132.81 | 3 | 7 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 35 | 13.64 | 632 | 302 | 0.30 / 1125.53 | 3 | 5 |
2 | 3 | 966.76 | -1 | 13.64 | 632 | 0 | 0.00 / 1125.53 | 3 | 5 |
3 | 12 | 1138.56 | 5 | 11.72 | 2076 | 122 | 0.42 / 1125.65 | 3 | 3 |
4 | 12 | 2010.96 | 50 | 10.23 | 3233 | 1654 | 2.08 / 1127.30 | 3 | 3 |
5 | 7 | 2007.16 | 25 | 10.56 | 3230 | 853 | 2.93 / 1128.16 | 3 | 3 |
6 | 13 | 1440.08 | 37 | 12.42 | 2451 | 1126 | 4.06 / 1129.28 | 3 | 6 |
7 | 13 | 482.88 | 37 | 13.44 | 1099 | 547 | 4.60 / 1129.83 | 3 | 11 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 34 | 13.63 | 651 | 302 | 0.30 / 1122.48 | 3 | 7 |
2 | 3 | 950.80 | -1 | 13.63 | 651 | 0 | 0.00 / 1122.48 | 3 | 7 |
3 | 12 | 1121.32 | 50 | 8.05 | 1899 | 764 | 1.07 / 1123.24 | 3 | 3 |
4 | 7 | 1124.04 | 25 | 10.71 | 2032 | 544 | 1.61 / 1123.79 | 3 | 3 |
5 | 13 | 1059.56 | 37 | 12.43 | 1907 | 877 | 2.49 / 1124.67 | 3 | 6 |
6 | 13 | 502.64 | 37 | 13.34 | 1138 | 562 | 3.05 / 1125.23 | 3 | 10 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 35 | 13.66 | 645 | 308 | 0.31 / 1119.62 | 3 | 7 |
2 | 3 | 913.32 | -2 | 13.66 | 645 | 0 | 0.00 / 1119.62 | 3 | 7 |
3 | 3 | 978.64 | -1 | 13.66 | 645 | 0 | 0.00 / 1119.62 | 3 | 7 |
4 | 12 | 1146.76 | 50 | 8.77 | 1952 | 856 | 1.16 / 1120.47 | 3 | 3 |
5 | 7 | 1149.12 | 25 | 10.84 | 2076 | 563 | 1.73 / 1121.04 | 3 | 3 |
6 | 13 | 1068.60 | 37 | 12.53 | 1918 | 889 | 2.62 / 1121.93 | 3 | 6 |
7 | 13 | 360.60 | 8 | 13.65 | 976 | 107 | 2.72 / 1122.03 | 3 | 10 |
8 | 13 | 230.40 | 5 | 13.74 | 806 | 55 | 2.78 / 1122.09 | 3 | 10 |
9 | 13 | 126.80 | 5 | 13.84 | 676 | 47 | 2.82 / 1122.14 | 3 | 8 |
10 | 13 | 80.80 | 5 | 13.86 | 624 | 43 | 2.87 / 1122.18 | 3 | 8 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 32 | 13.65 | 649 | 283 | 0.28 / 1116.66 | 3 | 5 |
2 | 3 | 1070.28 | 2 | 12.47 | 1983 | 49 | 0.33 / 1116.71 | 3 | 3 |
3 | 3 | 1023.20 | 1 | 11.83 | 1940 | 23 | 0.36 / 1116.74 | 3 | 3 |
4 | 12 | 1139.64 | 50 | 9.48 | 1993 | 945 | 1.30 / 1117.68 | 3 | 3 |
5 | 7 | 1141.20 | 25 | 11.08 | 2052 | 568 | 1.87 / 1118.25 | 3 | 4 |
6 | 13 | 1039.44 | 37 | 12.67 | 1880 | 881 | 2.75 / 1119.13 | 3 | 7 |
7 | 13 | 177.16 | 5 | 13.82 | 723 | 50 | 2.80 / 1119.18 | 3 | 8 |
8 | 13 | 106.12 | 5 | 13.82 | 655 | 45 | 2.85 / 1119.23 | 3 | 8 |
9 | 13 | 74.72 | 5 | 13.85 | 618 | 43 | 2.89 / 1119.27 | 3 | 7 |
10 | 13 | 57.12 | 5 | 13.88 | 600 | 42 | 2.93 / 1119.31 | 3 | 7 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 32 | 13.63 | 636 | 277 | 0.28 / 1111.94 | 3 | 4 |
2 | 3 | 1049.96 | 1 | 11.98 | 1945 | 23 | 0.30 / 1111.96 | 3 | 3 |
3 | 3 | 1034.40 | 1 | 11.63 | 1930 | 22 | 0.32 / 1111.98 | 3 | 3 |
4 | 12 | 1125.84 | 5 | 11.85 | 2064 | 122 | 0.45 / 1112.11 | 3 | 3 |
5 | 12 | 2002.80 | 50 | 10.39 | 3217 | 1671 | 2.12 / 1113.78 | 3 | 3 |
6 | 7 | 1998.76 | 25 | 10.56 | 3221 | 850 | 2.97 / 1114.63 | 3 | 3 |
7 | 13 | 1589.88 | 37 | 12.27 | 2648 | 1202 | 4.17 / 1115.83 | 3 | 5 |
8 | 13 | 475.16 | 37 | 13.41 | 1112 | 552 | 4.72 / 1116.38 | 3 | 10 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 35 | 13.60 | 656 | 312 | 0.31 / 1108.89 | 3 | 6 |
2 | 3 | 950.48 | -1 | 13.60 | 656 | 0 | 0.00 / 1108.89 | 3 | 6 |
3 | 12 | 1122.52 | 50 | 8.22 | 1916 | 787 | 1.10 / 1109.68 | 3 | 3 |
4 | 7 | 1125.52 | 25 | 10.79 | 2045 | 552 | 1.65 / 1110.23 | 3 | 3 |
5 | 13 | 1052.08 | 37 | 12.47 | 1898 | 876 | 2.53 / 1111.11 | 3 | 6 |
6 | 13 | 492.00 | 37 | 13.36 | 1113 | 550 | 3.08 / 1111.66 | 3 | 10 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 33 | 13.63 | 649 | 292 | 0.29 / 1105.94 | 3 | 6 |
2 | 3 | 975.88 | -1 | 13.63 | 649 | 0 | 0.00 / 1105.94 | 3 | 6 |
3 | 12 | 1154.12 | 50 | 8.83 | 1947 | 860 | 1.15 / 1106.80 | 3 | 3 |
4 | 7 | 1156.16 | 25 | 10.90 | 2071 | 564 | 1.72 / 1107.36 | 3 | 3 |
5 | 13 | 1061.92 | 37 | 12.55 | 1912 | 888 | 2.60 / 1108.25 | 3 | 6 |
6 | 13 | 305.76 | 6 | 13.72 | 904 | 74 | 2.68 / 1108.32 | 3 | 10 |
7 | 13 | 177.24 | 5 | 13.78 | 745 | 51 | 2.73 / 1108.37 | 3 | 9 |
8 | 13 | 108.04 | 5 | 13.80 | 661 | 46 | 2.78 / 1108.42 | 3 | 8 |
9 | 13 | 52.84 | 5 | 13.85 | 598 | 41 | 2.82 / 1108.46 | 3 | 7 |
10 | 13 | 46.68 | 5 | 13.83 | 591 | 41 | 2.86 / 1108.50 | 3 | 7 |
11 | 13 | 43.68 | 5 | 13.80 | 581 | 40 | 2.90 / 1108.54 | 3 | 7 |
12 | 13 | 40.56 | 5 | 13.78 | 578 | 40 | 2.94 / 1108.58 | 3 | 6 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 32 | 13.66 | 653 | 285 | 0.29 / 1102.99 | 3 | 5 |
2 | 3 | 1020.08 | 1 | 11.89 | 1910 | 23 | 0.31 / 1103.01 | 3 | 3 |
3 | 12 | 1147.48 | 50 | 9.59 | 1986 | 952 | 1.26 / 1103.97 | 3 | 3 |
4 | 7 | 1149.08 | 25 | 11.12 | 2062 | 573 | 1.83 / 1104.54 | 3 | 4 |
5 | 13 | 1047.24 | 37 | 12.69 | 1886 | 886 | 2.72 / 1105.43 | 3 | 7 |
6 | 13 | 162.40 | 5 | 13.80 | 715 | 49 | 2.77 / 1105.47 | 3 | 8 |
7 | 13 | 107.60 | 5 | 13.84 | 656 | 45 | 2.81 / 1105.52 | 3 | 8 |
8 | 13 | 74.80 | 5 | 13.87 | 617 | 43 | 2.86 / 1105.56 | 3 | 7 |
9 | 13 | 57.32 | 5 | 13.85 | 605 | 42 | 2.90 / 1105.60 | 3 | 7 |
10 | 13 | 48.04 | 5 | 13.86 | 587 | 41 | 2.94 / 1105.65 | 3 | 7 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 34 | 13.66 | 626 | 291 | 0.29 / 1098.67 | 3 | 6 |
2 | 3 | 926.52 | -2 | 13.66 | 626 | 0 | 0.00 / 1098.67 | 3 | 6 |
3 | 12 | 1111.40 | 5 | 11.92 | 2035 | 121 | 0.41 / 1098.80 | 3 | 3 |
4 | 12 | 2005.00 | 50 | 10.36 | 3224 | 1670 | 2.08 / 1100.47 | 3 | 3 |
5 | 7 | 2000.68 | 25 | 10.60 | 3221 | 854 | 2.94 / 1101.32 | 3 | 3 |
6 | 13 | 1418.80 | 37 | 12.45 | 2433 | 1121 | 4.06 / 1102.44 | 3 | 6 |
7 | 13 | 335.44 | 7 | 13.74 | 959 | 92 | 4.15 / 1102.53 | 3 | 10 |
8 | 13 | 121.24 | 5 | 13.84 | 680 | 47 | 4.20 / 1102.58 | 3 | 8 |
9 | 13 | 82.16 | 5 | 13.86 | 631 | 44 | 4.24 / 1102.62 | 3 | 7 |
10 | 13 | 60.64 | 5 | 13.89 | 603 | 42 | 4.28 / 1102.66 | 3 | 7 |
11 | 13 | 49.68 | 5 | 13.86 | 598 | 41 | 4.32 / 1102.71 | 3 | 7 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 33 | 13.63 | 639 | 287 | 0.29 / 1095.78 | 3 | 5 |
2 | 10 | 1017.20 | 3 | 12.85 | 1953 | 75 | 0.36 / 1095.85 | 3 | 4 |
3 | 3 | 976.68 | -1 | 12.85 | 1953 | 0 | 0.08 / 1095.85 | 3 | 4 |
4 | 12 | 1138.72 | 50 | 8.44 | 1925 | 812 | 1.18 / 1096.66 | 3 | 3 |
5 | 7 | 1141.08 | 25 | 10.88 | 2048 | 557 | 1.73 / 1097.22 | 3 | 3 |
6 | 13 | 1063.84 | 37 | 12.55 | 1901 | 883 | 2.61 / 1098.10 | 3 | 6 |
7 | 13 | 366.16 | 8 | 13.64 | 987 | 108 | 2.72 / 1098.21 | 3 | 10 |
8 | 13 | 135.20 | 5 | 13.81 | 674 | 47 | 2.77 / 1098.26 | 3 | 8 |
9 | 13 | 91.00 | 5 | 13.81 | 628 | 43 | 2.81 / 1098.30 | 3 | 7 |
10 | 13 | 65.44 | 5 | 13.85 | 603 | 42 | 2.85 / 1098.34 | 3 | 6 |
11 | 13 | 52.20 | 5 | 13.85 | 589 | 41 | 2.89 / 1098.38 | 3 | 7 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 32 | 13.67 | 637 | 279 | 0.28 / 1092.69 | 3 | 6 |
2 | 12 | 1121.16 | 50 | 8.98 | 1923 | 863 | 1.14 / 1093.55 | 3 | 3 |
3 | 7 | 1123.24 | 25 | 10.91 | 2033 | 555 | 1.70 / 1094.11 | 3 | 3 |
4 | 13 | 1032.28 | 37 | 12.58 | 1857 | 864 | 2.56 / 1094.97 | 3 | 6 |
5 | 13 | 440.24 | 37 | 13.42 | 1038 | 515 | 3.08 / 1095.49 | 3 | 10 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 32 | 13.70 | 627 | 275 | 0.27 / 1089.86 | 3 | 5 |
2 | 12 | 1142.52 | 50 | 9.71 | 1979 | 961 | 1.24 / 1090.82 | 3 | 3 |
3 | 7 | 1143.84 | 25 | 11.17 | 2046 | 571 | 1.81 / 1091.39 | 3 | 4 |
4 | 13 | 1035.96 | 37 | 12.69 | 1881 | 883 | 2.69 / 1092.28 | 3 | 7 |
5 | 13 | 155.00 | 5 | 13.81 | 700 | 48 | 2.74 / 1092.32 | 3 | 8 |
6 | 13 | 101.48 | 5 | 13.84 | 646 | 45 | 2.78 / 1092.37 | 3 | 8 |
7 | 13 | 70.68 | 5 | 13.85 | 611 | 42 | 2.83 / 1092.41 | 3 | 7 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 32 | 13.62 | 647 | 282 | 0.28 / 1085.48 | 3 | 5 |
2 | 3 | 1058.52 | 2 | 12.15 | 1975 | 48 | 0.33 / 1085.53 | 3 | 3 |
3 | 3 | 1020.04 | 1 | 11.43 | 1916 | 22 | 0.35 / 1085.55 | 3 | 3 |
4 | 12 | 1142.88 | 5 | 12.03 | 2084 | 125 | 0.48 / 1085.68 | 3 | 3 |
5 | 12 | 2002.28 | 50 | 10.49 | 3215 | 1686 | 2.16 / 1087.36 | 3 | 3 |
6 | 7 | 1998.24 | 25 | 10.66 | 3195 | 851 | 3.01 / 1088.22 | 3 | 3 |
7 | 13 | 1420.84 | 37 | 12.46 | 2418 | 1115 | 4.13 / 1089.33 | 3 | 6 |
8 | 13 | 345.96 | 7 | 13.72 | 944 | 91 | 4.22 / 1089.42 | 3 | 10 |
9 | 13 | 125.40 | 5 | 13.84 | 660 | 46 | 4.27 / 1089.47 | 3 | 8 |
10 | 13 | 48.92 | 5 | 13.89 | 579 | 40 | 4.31 / 1089.51 | 3 | 7 |
11 | 13 | 44.92 | 5 | 13.85 | 579 | 40 | 4.35 / 1089.55 | 3 | 6 |
12 | 13 | 41.64 | 5 | 13.83 | 573 | 40 | 4.39 / 1089.59 | 3 | 6 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 33 | 13.61 | 645 | 290 | 0.29 / 1082.42 | 3 | 6 |
2 | 12 | 1123.88 | 50 | 8.56 | 1912 | 818 | 1.11 / 1083.23 | 3 | 3 |
3 | 7 | 1126.44 | 25 | 10.89 | 2028 | 552 | 1.66 / 1083.79 | 3 | 3 |
4 | 13 | 1043.76 | 37 | 12.51 | 1888 | 874 | 2.53 / 1084.66 | 3 | 6 |
5 | 13 | 477.40 | 37 | 13.37 | 1093 | 541 | 3.07 / 1085.20 | 3 | 10 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 33 | 13.62 | 661 | 297 | 0.30 / 1079.52 | 3 | 6 |
2 | 3 | 961.20 | -1 | 13.62 | 661 | 0 | 0.00 / 1079.52 | 3 | 6 |
3 | 12 | 1122.92 | 50 | 9.06 | 1926 | 872 | 1.17 / 1080.39 | 3 | 3 |
4 | 7 | 1124.96 | 25 | 11.00 | 2026 | 557 | 1.73 / 1080.95 | 3 | 3 |
5 | 13 | 1044.16 | 37 | 12.60 | 1876 | 875 | 2.60 / 1081.82 | 3 | 7 |
6 | 13 | 333.36 | 7 | 13.67 | 930 | 89 | 2.69 / 1081.91 | 3 | 10 |
7 | 13 | 119.64 | 5 | 13.80 | 676 | 47 | 2.74 / 1081.96 | 3 | 8 |
8 | 13 | 85.32 | 5 | 13.82 | 626 | 43 | 2.78 / 1082.00 | 3 | 7 |
9 | 13 | 64.84 | 5 | 13.84 | 599 | 41 | 2.82 / 1082.04 | 3 | 7 |
10 | 13 | 52.52 | 5 | 13.82 | 593 | 41 | 2.86 / 1082.09 | 3 | 7 |
11 | 13 | 42.28 | 5 | 13.83 | 578 | 40 | 2.90 / 1082.13 | 3 | 7 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 33 | 13.65 | 643 | 290 | 0.29 / 1076.65 | 3 | 5 |
2 | 12 | 1130.12 | 50 | 9.66 | 1965 | 949 | 1.24 / 1077.60 | 3 | 3 |
3 | 7 | 1131.84 | 25 | 11.20 | 2026 | 567 | 1.81 / 1078.17 | 3 | 4 |
4 | 13 | 1033.88 | 37 | 12.72 | 1869 | 880 | 2.69 / 1079.05 | 3 | 7 |
5 | 13 | 152.12 | 5 | 13.79 | 690 | 48 | 2.73 / 1079.10 | 3 | 8 |
6 | 13 | 93.72 | 5 | 13.83 | 637 | 44 | 2.78 / 1079.14 | 3 | 8 |
7 | 13 | 68.84 | 5 | 13.84 | 609 | 42 | 2.82 / 1079.18 | 3 | 7 |
8 | 13 | 54.00 | 5 | 13.83 | 594 | 41 | 2.86 / 1079.22 | 3 | 7 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 33 | 13.62 | 649 | 292 | 0.29 / 1072.26 | 3 | 6 |
2 | 3 | 971.16 | -1 | 13.62 | 649 | 0 | 0.00 / 1072.26 | 3 | 6 |
3 | 12 | 1127.08 | 5 | 12.01 | 2091 | 126 | 0.42 / 1072.39 | 3 | 3 |
4 | 12 | 2006.40 | 50 | 10.47 | 3222 | 1687 | 2.10 / 1074.08 | 3 | 3 |
5 | 7 | 2002.04 | 25 | 10.60 | 3222 | 854 | 2.96 / 1074.93 | 3 | 3 |
6 | 13 | 1433.80 | 37 | 12.46 | 2443 | 1126 | 4.08 / 1076.06 | 3 | 6 |
7 | 13 | 348.60 | 7 | 13.72 | 957 | 92 | 4.18 / 1076.15 | 3 | 10 |
8 | 13 | 121.44 | 5 | 13.86 | 661 | 46 | 4.22 / 1076.19 | 3 | 8 |
9 | 13 | 82.96 | 5 | 13.86 | 625 | 43 | 4.27 / 1076.24 | 3 | 8 |
10 | 13 | 62.96 | 5 | 13.86 | 608 | 42 | 4.31 / 1076.28 | 3 | 7 |
11 | 13 | 52.20 | 5 | 13.84 | 595 | 41 | 4.35 / 1076.32 | 3 | 7 |
12 | 13 | 45.88 | 5 | 13.85 | 591 | 41 | 4.39 / 1076.36 | 3 | 7 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 33 | 13.64 | 645 | 290 | 0.29 / 1069.41 | 3 | 5 |
2 | 12 | 1128.52 | 50 | 8.86 | 1946 | 862 | 1.15 / 1070.27 | 3 | 3 |
3 | 7 | 1131.16 | 25 | 10.94 | 2034 | 556 | 1.71 / 1070.83 | 3 | 3 |
4 | 13 | 1051.96 | 37 | 12.54 | 1882 | 873 | 2.58 / 1071.70 | 3 | 6 |
5 | 13 | 336.24 | 7 | 13.63 | 972 | 93 | 2.67 / 1071.79 | 3 | 10 |
6 | 13 | 207.44 | 5 | 13.74 | 785 | 54 | 2.73 / 1071.85 | 3 | 9 |
7 | 13 | 78.24 | 5 | 13.82 | 620 | 43 | 2.77 / 1071.89 | 3 | 7 |
8 | 13 | 59.08 | 5 | 13.82 | 602 | 42 | 2.81 / 1071.93 | 3 | 7 |
9 | 13 | 48.64 | 5 | 13.81 | 593 | 41 | 2.85 / 1071.97 | 3 | 7 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 34 | 13.66 | 641 | 298 | 0.30 / 1066.55 | 3 | 6 |
2 | 3 | 975.88 | -1 | 13.66 | 641 | 0 | 0.00 / 1066.55 | 3 | 6 |
3 | 12 | 1134.52 | 50 | 9.25 | 1955 | 904 | 1.20 / 1067.45 | 3 | 3 |
4 | 7 | 1136.44 | 25 | 11.03 | 2052 | 566 | 1.77 / 1068.02 | 3 | 3 |
5 | 13 | 1040.32 | 37 | 12.68 | 1870 | 877 | 2.65 / 1068.89 | 3 | 7 |
6 | 13 | 193.12 | 5 | 13.76 | 753 | 52 | 2.70 / 1068.95 | 3 | 9 |
7 | 13 | 116.20 | 5 | 13.80 | 676 | 47 | 2.74 / 1068.99 | 3 | 8 |
8 | 13 | 80.48 | 5 | 13.82 | 624 | 43 | 2.79 / 1069.04 | 3 | 7 |
9 | 13 | 60.96 | 5 | 13.85 | 605 | 42 | 2.83 / 1069.08 | 3 | 7 |
10 | 13 | 50.36 | 5 | 13.83 | 594 | 41 | 2.87 / 1069.12 | 3 | 6 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 33 | 13.64 | 652 | 293 | 0.29 / 1063.60 | 3 | 5 |
2 | 3 | 1020.96 | 1 | 11.92 | 1937 | 23 | 0.32 / 1063.62 | 3 | 3 |
3 | 12 | 1149.00 | 50 | 9.82 | 1995 | 980 | 1.30 / 1064.60 | 3 | 3 |
4 | 7 | 1150.40 | 25 | 11.23 | 2053 | 576 | 1.87 / 1065.17 | 3 | 4 |
5 | 13 | 1047.88 | 37 | 12.74 | 1900 | 896 | 2.77 / 1066.07 | 3 | 7 |
6 | 13 | 166.28 | 5 | 13.82 | 719 | 50 | 2.82 / 1066.12 | 3 | 9 |
7 | 13 | 100.12 | 5 | 13.82 | 652 | 45 | 2.86 / 1066.17 | 3 | 8 |
8 | 13 | 69.48 | 5 | 13.84 | 617 | 43 | 2.91 / 1066.21 | 3 | 6 |
9 | 13 | 54.16 | 5 | 13.86 | 599 | 42 | 2.95 / 1066.25 | 3 | 7 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 34 | 13.63 | 644 | 298 | 0.30 / 1059.18 | 3 | 5 |
2 | 3 | 962.68 | -1 | 13.63 | 644 | 0 | 0.00 / 1059.18 | 3 | 5 |
3 | 12 | 1119.44 | 5 | 12.09 | 2048 | 124 | 0.42 / 1059.30 | 3 | 3 |
4 | 12 | 2008.44 | 50 | 10.55 | 3220 | 1699 | 2.12 / 1061.00 | 3 | 3 |
5 | 7 | 2004.36 | 25 | 10.65 | 3228 | 859 | 2.98 / 1061.86 | 3 | 3 |
6 | 13 | 1439.68 | 37 | 12.46 | 2457 | 1133 | 4.11 / 1062.99 | 3 | 6 |
7 | 13 | 222.88 | 5 | 13.80 | 788 | 54 | 4.17 / 1063.05 | 3 | 10 |
8 | 13 | 132.28 | 5 | 13.82 | 684 | 47 | 4.21 / 1063.09 | 3 | 9 |
9 | 13 | 82.68 | 5 | 13.85 | 627 | 43 | 4.26 / 1063.14 | 3 | 7 |
10 | 13 | 62.84 | 5 | 13.88 | 605 | 42 | 4.30 / 1063.18 | 3 | 7 |
11 | 13 | 52.64 | 5 | 13.85 | 605 | 42 | 4.34 / 1063.22 | 3 | 8 |
12 | 13 | 46.96 | 5 | 13.85 | 599 | 41 | 4.38 / 1063.26 | 3 | 7 |
13 | 13 | 43.88 | 5 | 13.86 | 582 | 40 | 4.42 / 1063.30 | 3 | 7 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 33 | 13.62 | 647 | 291 | 0.29 / 1056.30 | 3 | 6 |
2 | 12 | 1141.32 | 50 | 9.14 | 1939 | 886 | 1.18 / 1057.18 | 3 | 3 |
3 | 7 | 1143.20 | 25 | 10.98 | 2039 | 560 | 1.74 / 1057.74 | 3 | 3 |
4 | 13 | 1048.36 | 37 | 12.61 | 1887 | 880 | 2.62 / 1058.62 | 3 | 6 |
5 | 13 | 324.48 | 7 | 13.70 | 917 | 88 | 2.70 / 1058.71 | 3 | 9 |
6 | 13 | 110.44 | 5 | 13.81 | 648 | 45 | 2.75 / 1058.75 | 3 | 8 |
7 | 13 | 77.40 | 5 | 13.81 | 615 | 42 | 2.79 / 1058.80 | 3 | 7 |
8 | 13 | 58.92 | 5 | 13.84 | 594 | 41 | 2.83 / 1058.84 | 3 | 7 |
9 | 13 | 49.12 | 5 | 13.81 | 587 | 41 | 2.87 / 1058.88 | 3 | 6 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 33 | 13.64 | 648 | 292 | 0.29 / 1053.35 | 3 | 5 |
2 | 12 | 1147.00 | 50 | 9.44 | 1950 | 920 | 1.21 / 1054.27 | 3 | 3 |
3 | 7 | 1148.72 | 25 | 11.08 | 2048 | 567 | 1.78 / 1054.84 | 3 | 4 |
4 | 13 | 1051.72 | 37 | 12.70 | 1876 | 882 | 2.66 / 1055.72 | 3 | 6 |
5 | 13 | 305.44 | 6 | 13.72 | 897 | 74 | 2.73 / 1055.79 | 3 | 10 |
6 | 13 | 173.72 | 5 | 13.79 | 733 | 51 | 2.79 / 1055.84 | 3 | 9 |
7 | 13 | 68.32 | 5 | 13.83 | 606 | 42 | 2.83 / 1055.88 | 3 | 6 |
8 | 13 | 54.24 | 5 | 13.84 | 589 | 41 | 2.87 / 1055.92 | 3 | 6 |
9 | 13 | 47.20 | 5 | 13.82 | 583 | 40 | 2.91 / 1055.96 | 3 | 7 |
10 | 13 | 43.40 | 5 | 13.80 | 580 | 40 | 2.95 / 1056.00 | 3 | 6 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 35 | 13.68 | 650 | 311 | 0.31 / 1050.43 | 3 | 7 |
2 | 3 | 910.48 | -2 | 13.68 | 650 | 0 | 0.00 / 1050.43 | 3 | 7 |
3 | 3 | 972.92 | -1 | 13.68 | 650 | 0 | 0.00 / 1050.43 | 3 | 7 |
4 | 12 | 1140.24 | 50 | 9.90 | 1982 | 981 | 1.29 / 1051.41 | 3 | 3 |
5 | 7 | 1141.36 | 25 | 11.26 | 2059 | 580 | 1.87 / 1051.99 | 3 | 4 |
6 | 13 | 1033.76 | 37 | 12.77 | 1870 | 884 | 2.76 / 1052.87 | 3 | 7 |
7 | 13 | 275.40 | 5 | 13.76 | 869 | 60 | 2.82 / 1052.93 | 3 | 10 |
8 | 13 | 91.28 | 5 | 13.84 | 635 | 44 | 2.86 / 1052.97 | 3 | 7 |
9 | 13 | 66.88 | 5 | 13.84 | 603 | 42 | 2.90 / 1053.02 | 3 | 7 |
10 | 13 | 54.40 | 5 | 13.84 | 595 | 41 | 2.94 / 1053.06 | 3 | 7 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 42 | 13.56 | 645 | 367 | 0.37 / 1046.01 | 3 | 7 |
2 | 3 | 735.36 | -7 | 13.56 | 645 | 0 | 0.00 / 1046.01 | 3 | 7 |
3 | 3 | 943.32 | -1 | 13.56 | 645 | 0 | 0.00 / 1046.01 | 3 | 7 |
4 | 12 | 1113.20 | 5 | 12.18 | 2053 | 125 | 0.49 / 1046.13 | 3 | 3 |
5 | 12 | 2008.88 | 50 | 10.69 | 3234 | 1729 | 2.22 / 1047.86 | 3 | 3 |
6 | 7 | 2004.84 | 25 | 10.75 | 3212 | 863 | 3.08 / 1048.73 | 3 | 3 |
7 | 13 | 1428.16 | 37 | 12.52 | 2438 | 1129 | 4.21 / 1049.86 | 3 | 6 |
8 | 13 | 322.40 | 7 | 13.77 | 914 | 88 | 4.30 / 1049.94 | 3 | 10 |
9 | 13 | 111.24 | 5 | 13.85 | 662 | 46 | 4.35 / 1049.99 | 3 | 8 |
10 | 13 | 75.52 | 5 | 13.87 | 614 | 43 | 4.39 / 1050.03 | 3 | 7 |
11 | 13 | 59.08 | 5 | 13.87 | 598 | 41 | 4.43 / 1050.07 | 3 | 7 |
12 | 13 | 48.68 | 5 | 13.87 | 587 | 41 | 4.47 / 1050.11 | 3 | 8 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 24 | 13.72 | 648 | 213 | 0.21 / 1042.73 | 3 | 3 |
2 | 10 | 1039.92 | 4 | 13.05 | 1958 | 102 | 0.32 / 1042.84 | 3 | 4 |
3 | 3 | 1109.88 | 3 | 13.00 | 2057 | 80 | 0.40 / 1042.92 | 3 | 4 |
4 | 3 | 1059.92 | 2 | 12.57 | 1970 | 50 | 0.45 / 1042.97 | 3 | 3 |
5 | 12 | 1151.04 | 50 | 9.25 | 1971 | 912 | 1.36 / 1043.88 | 3 | 3 |
6 | 7 | 1152.88 | 25 | 11.06 | 2057 | 569 | 1.93 / 1044.45 | 3 | 3 |
7 | 13 | 1057.76 | 37 | 12.70 | 1902 | 894 | 2.82 / 1045.34 | 3 | 7 |
8 | 13 | 326.68 | 7 | 13.71 | 930 | 89 | 2.91 / 1045.43 | 3 | 10 |
9 | 13 | 116.24 | 5 | 13.82 | 671 | 46 | 2.96 / 1045.48 | 3 | 8 |
10 | 13 | 78.60 | 5 | 13.82 | 623 | 43 | 3.00 / 1045.52 | 3 | 7 |
11 | 13 | 59.12 | 5 | 13.82 | 603 | 42 | 3.04 / 1045.56 | 3 | 7 |
12 | 13 | 48.96 | 5 | 13.81 | 597 | 41 | 3.08 / 1045.60 | 3 | 7 |
13 | 13 | 44.68 | 5 | 13.81 | 588 | 41 | 3.12 / 1045.64 | 3 | 7 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 43 | 13.60 | 642 | 375 | 0.38 / 1039.86 | 3 | 6 |
2 | 3 | 748.48 | -7 | 13.60 | 642 | 0 | 0.00 / 1039.86 | 3 | 6 |
3 | 3 | 956.84 | -1 | 13.60 | 642 | 0 | 0.00 / 1039.86 | 3 | 6 |
4 | 12 | 1140.16 | 50 | 9.55 | 1979 | 945 | 1.32 / 1040.80 | 3 | 3 |
5 | 7 | 1141.80 | 25 | 11.18 | 2044 | 571 | 1.89 / 1041.37 | 3 | 4 |
6 | 13 | 1045.52 | 37 | 12.77 | 1868 | 883 | 2.77 / 1042.26 | 3 | 7 |
7 | 13 | 177.80 | 5 | 13.79 | 732 | 50 | 2.82 / 1042.31 | 3 | 9 |
8 | 13 | 112.76 | 5 | 13.82 | 653 | 45 | 2.87 / 1042.35 | 3 | 8 |
9 | 13 | 77.52 | 5 | 13.83 | 627 | 43 | 2.91 / 1042.40 | 3 | 7 |
10 | 13 | 60.20 | 5 | 13.85 | 607 | 42 | 2.96 / 1042.44 | 3 | 7 |
11 | 13 | 49.72 | 5 | 13.82 | 607 | 42 | 3.00 / 1042.48 | 3 | 7 |
12 | 13 | 44.84 | 5 | 13.82 | 595 | 41 | 3.04 / 1042.52 | 3 | 7 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 43 | 13.55 | 647 | 377 | 0.38 / 1036.81 | 3 | 6 |
2 | 12 | 1141.48 | 50 | 10.00 | 1981 | 990 | 1.37 / 1037.80 | 3 | 3 |
3 | 7 | 1142.40 | 25 | 11.39 | 2033 | 579 | 1.95 / 1038.38 | 3 | 4 |
4 | 13 | 1035.12 | 37 | 12.86 | 1870 | 890 | 2.84 / 1039.27 | 3 | 7 |
5 | 13 | 149.40 | 5 | 13.83 | 702 | 49 | 2.88 / 1039.32 | 3 | 8 |
6 | 13 | 93.68 | 5 | 13.83 | 644 | 45 | 2.93 / 1039.36 | 3 | 8 |
7 | 13 | 65.48 | 5 | 13.86 | 603 | 42 | 2.97 / 1039.40 | 3 | 7 |
8 | 13 | 45.80 | 5 | 13.88 | 583 | 40 | 3.01 / 1039.44 | 3 | 6 |
9 | 13 | 42.76 | 5 | 13.84 | 586 | 41 | 3.05 / 1039.48 | 3 | 6 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 33 | 13.64 | 646 | 291 | 0.29 / 1030.87 | 3 | 4 |
2 | 10 | 1006.44 | 5 | 13.21 | 1885 | 125 | 0.42 / 1030.99 | 3 | 4 |
3 | 10 | 1039.24 | 3 | 13.39 | 1949 | 78 | 0.49 / 1031.07 | 3 | 5 |
4 | 12 | 1127.24 | 5 | 12.49 | 2064 | 129 | 0.62 / 1031.20 | 3 | 3 |
5 | 12 | 2007.32 | 50 | 11.08 | 3232 | 1791 | 2.41 / 1032.99 | 3 | 3 |
6 | 7 | 2002.72 | 25 | 10.94 | 3215 | 879 | 3.29 / 1033.87 | 3 | 3 |
7 | 13 | 1285.24 | 37 | 12.72 | 2226 | 1048 | 4.34 / 1034.92 | 3 | 7 |
8 | 13 | 215.48 | 5 | 13.83 | 798 | 55 | 4.40 / 1034.97 | 3 | 9 |
9 | 13 | 121.32 | 5 | 13.85 | 677 | 47 | 4.44 / 1035.02 | 3 | 8 |
10 | 13 | 78.40 | 5 | 13.88 | 620 | 43 | 4.49 / 1035.06 | 3 | 7 |
11 | 13 | 57.68 | 5 | 13.89 | 594 | 41 | 4.53 / 1035.11 | 3 | 8 |
12 | 13 | 48.40 | 5 | 13.90 | 578 | 40 | 4.57 / 1035.15 | 3 | 7 |
13 | 8 | 0.12 | 190 | 13.52 | 500 | 1284 | 5.85 / 1036.43 | 3 | 11 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 44 | 13.54 | 636 | 379 | 0.38 / 1024.58 | 3 | 7 |
2 | 3 | 959.36 | -1 | 13.54 | 636 | 0 | 0.00 / 1024.58 | 3 | 7 |
3 | 12 | 2003.16 | 34 | 8.25 | 2952 | 828 | 1.21 / 1025.41 | 3 | 3 |
4 | 7 | 2005.00 | 25 | 10.43 | 3215 | 838 | 2.05 / 1026.25 | 3 | 3 |
5 | 13 | 1926.48 | 37 | 11.85 | 3117 | 1367 | 3.41 / 1027.62 | 3 | 3 |
6 | 13 | 1516.60 | 37 | 12.44 | 2528 | 1164 | 4.58 / 1028.78 | 3 | 5 |
7 | 13 | 438.68 | 37 | 13.47 | 1054 | 525 | 5.10 / 1029.31 | 3 | 11 |
8 | 8 | 0.00 | 190 | 13.51 | 496 | 1273 | 6.37 / 1030.58 | 3 | 10 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 44 | 13.56 | 628 | 375 | 0.37 / 1018.28 | 3 | 8 |
2 | 12 | 2002.76 | 34 | 8.81 | 3000 | 899 | 1.27 / 1019.17 | 3 | 3 |
3 | 7 | 2004.00 | 25 | 10.55 | 3219 | 849 | 2.12 / 1020.02 | 3 | 3 |
4 | 13 | 1913.52 | 37 | 11.88 | 3091 | 1359 | 3.48 / 1021.38 | 3 | 3 |
5 | 13 | 1497.56 | 37 | 12.43 | 2522 | 1160 | 4.64 / 1022.54 | 3 | 5 |
6 | 13 | 264.20 | 37 | 13.66 | 797 | 403 | 5.04 / 1022.95 | 3 | 8 |
7 | 8 | 0.20 | 190 | 13.51 | 491 | 1260 | 6.30 / 1024.21 | 3 | 9 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 43 | 13.58 | 624 | 364 | 0.36 / 1011.97 | 3 | 7 |
2 | 3 | 1030.76 | 1 | 12.67 | 1907 | 24 | 0.39 / 1011.99 | 3 | 3 |
3 | 12 | 2005.88 | 34 | 8.41 | 3027 | 866 | 1.25 / 1012.86 | 3 | 3 |
4 | 7 | 2007.76 | 25 | 10.45 | 3207 | 838 | 2.09 / 1013.70 | 3 | 3 |
5 | 13 | 1929.80 | 37 | 11.76 | 3093 | 1346 | 3.44 / 1015.04 | 3 | 3 |
6 | 13 | 1520.92 | 37 | 12.39 | 2541 | 1165 | 4.60 / 1016.21 | 3 | 5 |
7 | 13 | 317.20 | 37 | 13.60 | 855 | 430 | 5.03 / 1016.64 | 3 | 9 |
8 | 8 | 0.48 | 190 | 13.51 | 492 | 1263 | 6.30 / 1017.90 | 3 | 6 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 42 | 13.58 | 632 | 360 | 0.36 / 1005.47 | 3 | 7 |
2 | 3 | 1025.04 | 1 | 12.31 | 1898 | 23 | 0.38 / 1005.50 | 3 | 3 |
3 | 12 | 2004.28 | 34 | 8.01 | 2967 | 808 | 1.19 / 1006.31 | 3 | 3 |
4 | 7 | 2006.16 | 25 | 10.05 | 3168 | 796 | 1.99 / 1007.10 | 3 | 3 |
5 | 13 | 1931.48 | 37 | 11.41 | 3099 | 1308 | 3.30 / 1008.41 | 3 | 3 |
6 | 13 | 1535.00 | 37 | 12.30 | 2562 | 1166 | 4.46 / 1009.58 | 3 | 5 |
7 | 13 | 474.76 | 37 | 13.42 | 1100 | 546 | 5.01 / 1010.12 | 3 | 11 |
8 | 13 | 9.12 | 37 | 13.85 | 507 | 260 | 5.27 / 1010.38 | 3 | 6 |
9 | 8 | 0.08 | 190 | 13.48 | 478 | 1224 | 6.49 / 1011.61 | 3 | 9 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 33 | 13.65 | 611 | 275 | 0.28 / 998.87 | 3 | 4 |
2 | 10 | 1051.92 | 4 | 13.36 | 1926 | 103 | 0.38 / 998.97 | 3 | 4 |
3 | 3 | 1140.44 | 4 | 13.29 | 2074 | 110 | 0.49 / 999.08 | 3 | 5 |
4 | 3 | 1029.20 | 1 | 12.84 | 1930 | 25 | 0.51 / 999.11 | 3 | 3 |
5 | 12 | 2005.00 | 34 | 8.51 | 3023 | 875 | 1.39 / 999.98 | 3 | 3 |
6 | 7 | 2006.76 | 25 | 10.12 | 3180 | 805 | 2.19 / 1000.78 | 3 | 3 |
7 | 13 | 1924.56 | 37 | 11.42 | 3095 | 1308 | 3.50 / 1002.09 | 3 | 3 |
8 | 13 | 1650.56 | 37 | 12.14 | 2725 | 1224 | 4.72 / 1003.32 | 3 | 4 |
9 | 13 | 424.80 | 37 | 13.46 | 1022 | 509 | 5.23 / 1003.83 | 3 | 11 |
10 | 13 | 40.60 | 5 | 13.86 | 571 | 40 | 5.27 / 1003.86 | 3 | 7 |
11 | 8 | 0.20 | 190 | 13.52 | 486 | 1248 | 6.52 / 1005.11 | 3 | 9 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 33 | 13.66 | 620 | 279 | 0.28 / 992.33 | 3 | 6 |
2 | 12 | 2005.48 | 34 | 7.95 | 2975 | 804 | 1.08 / 993.13 | 3 | 3 |
3 | 7 | 2007.68 | 25 | 9.66 | 3185 | 769 | 1.85 / 993.90 | 3 | 3 |
4 | 13 | 1943.04 | 37 | 11.06 | 3137 | 1284 | 3.14 / 995.18 | 3 | 3 |
5 | 13 | 1682.04 | 37 | 11.78 | 2754 | 1200 | 4.34 / 996.38 | 3 | 4 |
6 | 13 | 648.40 | 37 | 13.23 | 1315 | 644 | 4.98 / 997.03 | 3 | 10 |
7 | 13 | 43.96 | 5 | 13.84 | 570 | 39 | 5.02 / 997.07 | 3 | 8 |
8 | 13 | 40.88 | 5 | 13.82 | 567 | 39 | 5.06 / 997.11 | 3 | 7 |
9 | 13 | 4.04 | 37 | 13.85 | 509 | 261 | 5.32 / 997.37 | 3 | 8 |
10 | 8 | 0.12 | 190 | 13.49 | 478 | 1225 | 6.55 / 998.59 | 3 | 9 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 33 | 13.67 | 630 | 284 | 0.28 / 987.26 | 3 | 6 |
2 | 12 | 2005.60 | 34 | 7.66 | 2924 | 762 | 1.05 / 988.02 | 3 | 3 |
3 | 7 | 2008.00 | 25 | 9.72 | 3175 | 772 | 1.82 / 988.80 | 3 | 3 |
4 | 13 | 1947.80 | 37 | 11.02 | 3134 | 1278 | 3.10 / 990.07 | 3 | 3 |
5 | 13 | 1819.88 | 37 | 11.49 | 2958 | 1258 | 4.35 / 991.33 | 3 | 3 |
6 | 13 | 639.08 | 37 | 13.24 | 1302 | 638 | 4.99 / 991.97 | 3 | 10 |
7 | 13 | 44.32 | 5 | 13.82 | 573 | 40 | 5.03 / 992.01 | 3 | 7 |
8 | 13 | 41.24 | 5 | 13.82 | 564 | 39 | 5.07 / 992.05 | 3 | 7 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 33 | 13.69 | 637 | 288 | 0.29 / 982.22 | 3 | 7 |
2 | 12 | 2004.96 | 34 | 7.62 | 2922 | 757 | 1.04 / 982.98 | 3 | 3 |
3 | 7 | 2007.08 | 25 | 9.68 | 3161 | 765 | 1.81 / 983.74 | 3 | 3 |
4 | 13 | 1942.00 | 37 | 11.02 | 3118 | 1271 | 3.08 / 985.01 | 3 | 3 |
5 | 13 | 1681.20 | 37 | 11.77 | 2771 | 1207 | 4.29 / 986.22 | 3 | 4 |
6 | 13 | 774.60 | 37 | 13.10 | 1478 | 716 | 5.00 / 986.94 | 3 | 9 |
7 | 13 | 46.88 | 5 | 13.84 | 576 | 40 | 5.04 / 986.98 | 3 | 7 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 33 | 13.71 | 628 | 284 | 0.28 / 977.11 | 3 | 6 |
2 | 12 | 2004.36 | 34 | 7.65 | 2946 | 766 | 1.05 / 977.87 | 3 | 3 |
3 | 7 | 2006.56 | 25 | 9.73 | 3167 | 770 | 1.82 / 978.64 | 3 | 3 |
4 | 13 | 1942.24 | 37 | 11.05 | 3129 | 1279 | 3.10 / 979.92 | 3 | 3 |
5 | 13 | 1810.88 | 37 | 11.55 | 2945 | 1259 | 4.36 / 981.18 | 3 | 3 |
6 | 13 | 752.20 | 37 | 13.12 | 1471 | 714 | 5.07 / 981.90 | 3 | 10 |
7 | 13 | 42.64 | 5 | 13.84 | 560 | 39 | 5.11 / 981.93 | 3 | 7 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 33 | 13.70 | 633 | 286 | 0.29 / 972.10 | 3 | 7 |
2 | 12 | 2003.44 | 34 | 7.64 | 2952 | 767 | 1.05 / 972.87 | 3 | 3 |
3 | 7 | 2005.60 | 25 | 9.78 | 3169 | 775 | 1.83 / 973.64 | 3 | 3 |
4 | 13 | 1937.44 | 37 | 11.05 | 3137 | 1283 | 3.11 / 974.92 | 3 | 3 |
5 | 13 | 1674.72 | 37 | 11.91 | 2756 | 1214 | 4.32 / 976.14 | 3 | 4 |
6 | 13 | 635.24 | 37 | 13.25 | 1312 | 643 | 4.97 / 976.78 | 3 | 10 |
7 | 13 | 46.96 | 5 | 13.84 | 577 | 40 | 5.01 / 976.82 | 3 | 7 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 33 | 13.67 | 655 | 295 | 0.30 / 967.10 | 3 | 7 |
2 | 12 | 2005.24 | 34 | 7.84 | 2979 | 794 | 1.09 / 967.89 | 3 | 3 |
3 | 7 | 2007.40 | 25 | 9.72 | 3176 | 772 | 1.86 / 968.66 | 3 | 3 |
4 | 13 | 1944.32 | 37 | 11.10 | 3125 | 1283 | 3.14 / 969.95 | 3 | 3 |
5 | 13 | 1687.16 | 37 | 11.92 | 2777 | 1225 | 4.37 / 971.17 | 3 | 4 |
6 | 13 | 645.84 | 37 | 13.26 | 1310 | 643 | 5.01 / 971.81 | 3 | 9 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 34 | 13.69 | 630 | 293 | 0.29 / 962.03 | 3 | 6 |
2 | 3 | 976.96 | -1 | 13.69 | 630 | 0 | 0.00 / 962.03 | 3 | 6 |
3 | 12 | 2004.60 | 34 | 7.72 | 2960 | 777 | 1.07 / 962.80 | 3 | 3 |
4 | 7 | 2006.56 | 25 | 9.78 | 3180 | 778 | 1.85 / 963.58 | 3 | 3 |
5 | 13 | 1937.76 | 37 | 11.13 | 3121 | 1285 | 3.13 / 964.87 | 3 | 3 |
6 | 13 | 1670.68 | 37 | 11.97 | 2758 | 1221 | 4.35 / 966.09 | 3 | 4 |
7 | 13 | 748.76 | 37 | 13.15 | 1469 | 715 | 5.07 / 966.80 | 3 | 9 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 34 | 13.68 | 631 | 293 | 0.29 / 956.90 | 3 | 6 |
2 | 12 | 2018.76 | 34 | 7.88 | 3019 | 809 | 1.10 / 957.70 | 3 | 3 |
3 | 7 | 2020.92 | 25 | 9.77 | 3197 | 781 | 1.88 / 958.49 | 3 | 3 |
4 | 13 | 1954.12 | 37 | 11.12 | 3150 | 1296 | 3.18 / 959.78 | 3 | 3 |
5 | 13 | 1823.84 | 37 | 11.70 | 2974 | 1287 | 4.47 / 961.07 | 3 | 3 |
6 | 13 | 600.68 | 37 | 13.30 | 1270 | 625 | 5.09 / 961.69 | 3 | 11 |
7 | 13 | 41.72 | 5 | 13.83 | 560 | 39 | 5.13 / 961.73 | 3 | 7 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 33 | 13.72 | 633 | 287 | 0.29 / 951.72 | 3 | 6 |
2 | 12 | 2004.88 | 34 | 7.92 | 3030 | 816 | 1.10 / 952.54 | 3 | 3 |
3 | 7 | 2007.00 | 25 | 9.86 | 3160 | 779 | 1.88 / 953.32 | 3 | 3 |
4 | 13 | 1943.40 | 37 | 11.25 | 3119 | 1298 | 3.18 / 954.62 | 3 | 3 |
5 | 13 | 1812.00 | 37 | 11.77 | 2944 | 1282 | 4.46 / 955.90 | 3 | 3 |
6 | 13 | 737.52 | 37 | 13.18 | 1441 | 703 | 5.16 / 956.60 | 3 | 8 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 33 | 13.67 | 639 | 288 | 0.29 / 946.74 | 3 | 6 |
2 | 12 | 2003.56 | 34 | 7.76 | 2939 | 775 | 1.06 / 947.52 | 3 | 3 |
3 | 7 | 2005.60 | 25 | 9.91 | 3157 | 782 | 1.85 / 948.30 | 3 | 3 |
4 | 13 | 1935.48 | 37 | 11.28 | 3103 | 1295 | 3.14 / 949.59 | 3 | 3 |
5 | 13 | 1667.44 | 37 | 12.04 | 2741 | 1221 | 4.36 / 950.81 | 3 | 4 |
6 | 13 | 610.44 | 37 | 13.31 | 1266 | 623 | 4.99 / 951.44 | 3 | 10 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 34 | 13.67 | 639 | 297 | 0.30 / 941.68 | 3 | 6 |
2 | 3 | 966.76 | -1 | 13.67 | 639 | 0 | 0.00 / 941.68 | 3 | 6 |
3 | 12 | 2016.40 | 34 | 7.98 | 2986 | 810 | 1.11 / 942.49 | 3 | 3 |
4 | 7 | 2018.16 | 25 | 9.90 | 3183 | 788 | 1.89 / 943.28 | 3 | 3 |
5 | 13 | 1944.28 | 37 | 11.30 | 3130 | 1309 | 3.20 / 944.58 | 3 | 3 |
6 | 13 | 1678.12 | 37 | 12.05 | 2749 | 1226 | 4.43 / 945.81 | 3 | 4 |
7 | 13 | 638.64 | 37 | 13.29 | 1306 | 642 | 5.07 / 946.45 | 3 | 9 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 33 | 13.70 | 634 | 287 | 0.29 / 936.51 | 3 | 6 |
2 | 12 | 2006.48 | 34 | 8.15 | 3011 | 834 | 1.12 / 937.35 | 3 | 3 |
3 | 7 | 2008.72 | 25 | 10.04 | 3174 | 797 | 1.92 / 938.15 | 3 | 3 |
4 | 13 | 1944.24 | 37 | 11.40 | 3124 | 1318 | 3.24 / 939.46 | 3 | 3 |
5 | 13 | 1813.08 | 37 | 11.85 | 2953 | 1295 | 4.53 / 940.76 | 3 | 3 |
6 | 13 | 596.16 | 37 | 13.31 | 1266 | 623 | 5.15 / 941.38 | 3 | 10 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 33 | 13.73 | 624 | 283 | 0.28 / 931.41 | 3 | 6 |
2 | 12 | 2004.52 | 34 | 7.99 | 2978 | 809 | 1.09 / 932.22 | 3 | 3 |
3 | 7 | 2006.68 | 25 | 10.02 | 3183 | 797 | 1.89 / 933.02 | 3 | 3 |
4 | 13 | 1939.72 | 37 | 11.39 | 3120 | 1315 | 3.20 / 934.34 | 3 | 3 |
5 | 13 | 1673.88 | 37 | 12.09 | 2761 | 1235 | 4.44 / 935.57 | 3 | 4 |
6 | 13 | 596.00 | 37 | 13.33 | 1253 | 618 | 5.06 / 936.19 | 3 | 9 |
7 | 13 | 40.60 | 5 | 13.83 | 556 | 38 | 5.10 / 936.23 | 3 | 6 |
Average= | 4.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 33 | 13.67 | 630 | 284 | 0.28 / 926.41 | 3 | 6 |
2 | 12 | 2017.88 | 34 | 7.85 | 2970 | 793 | 1.08 / 927.21 | 3 | 3 |
3 | 7 | 2019.92 | 25 | 10.00 | 3202 | 800 | 1.88 / 928.01 | 3 | 3 |
4 | 13 | 1948.60 | 37 | 11.40 | 3126 | 1319 | 3.20 / 929.33 | 3 | 3 |
5 | 13 | 1551.36 | 37 | 12.30 | 2579 | 1174 | 4.37 / 930.50 | 3 | 4 |
6 | 13 | 624.60 | 37 | 13.31 | 1283 | 632 | 5.00 / 931.13 | 3 | 8 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 33 | 13.71 | 620 | 281 | 0.28 / 921.38 | 3 | 6 |
2 | 12 | 2003.48 | 34 | 7.77 | 2912 | 769 | 1.05 / 922.15 | 3 | 3 |
3 | 7 | 2005.44 | 25 | 10.13 | 3176 | 804 | 1.85 / 922.96 | 3 | 3 |
4 | 13 | 1935.40 | 37 | 11.42 | 3123 | 1320 | 3.17 / 924.28 | 3 | 3 |
5 | 13 | 1670.20 | 37 | 12.16 | 2760 | 1242 | 4.42 / 925.52 | 3 | 4 |
6 | 13 | 600.16 | 37 | 13.33 | 1243 | 613 | 5.03 / 926.13 | 3 | 9 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 34 | 13.73 | 625 | 292 | 0.29 / 916.40 | 3 | 6 |
2 | 3 | 963.68 | -1 | 13.73 | 625 | 0 | 0.00 / 916.40 | 3 | 6 |
3 | 12 | 2004.88 | 34 | 7.81 | 2932 | 779 | 1.07 / 917.18 | 3 | 3 |
4 | 7 | 2007.08 | 25 | 10.15 | 3162 | 802 | 1.87 / 917.98 | 3 | 3 |
5 | 13 | 1936.04 | 37 | 11.46 | 3111 | 1319 | 3.19 / 919.30 | 3 | 3 |
6 | 13 | 1530.80 | 37 | 12.37 | 2571 | 1177 | 4.37 / 920.48 | 3 | 5 |
7 | 13 | 606.20 | 37 | 13.32 | 1270 | 626 | 4.99 / 921.10 | 3 | 10 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 34 | 13.70 | 622 | 290 | 0.29 / 911.31 | 3 | 6 |
2 | 12 | 2006.04 | 34 | 8.01 | 2986 | 813 | 1.10 / 912.13 | 3 | 3 |
3 | 7 | 2008.32 | 25 | 10.15 | 3176 | 806 | 1.91 / 912.93 | 3 | 3 |
4 | 13 | 1938.00 | 37 | 11.50 | 3118 | 1327 | 3.24 / 914.26 | 3 | 3 |
5 | 13 | 1672.76 | 37 | 12.21 | 2757 | 1246 | 4.48 / 915.51 | 3 | 4 |
6 | 13 | 580.92 | 37 | 13.35 | 1219 | 602 | 5.08 / 916.11 | 3 | 10 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 34 | 13.67 | 634 | 295 | 0.29 / 906.36 | 3 | 6 |
2 | 12 | 2003.84 | 34 | 8.12 | 2955 | 816 | 1.11 / 907.18 | 3 | 3 |
3 | 7 | 2005.68 | 25 | 10.28 | 3168 | 814 | 1.92 / 907.99 | 3 | 3 |
4 | 13 | 1926.72 | 37 | 11.58 | 3098 | 1327 | 3.25 / 909.32 | 3 | 3 |
5 | 13 | 1524.04 | 37 | 12.45 | 2540 | 1170 | 4.42 / 910.49 | 3 | 5 |
6 | 13 | 461.00 | 37 | 13.45 | 1079 | 537 | 4.96 / 911.02 | 3 | 10 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 35 | 13.72 | 639 | 307 | 0.31 / 901.37 | 3 | 6 |
2 | 3 | 971.80 | -1 | 13.72 | 639 | 0 | 0.00 / 901.37 | 3 | 6 |
3 | 12 | 2005.12 | 34 | 8.17 | 3011 | 836 | 1.14 / 902.21 | 3 | 3 |
4 | 7 | 2007.24 | 25 | 10.20 | 3178 | 810 | 1.95 / 903.02 | 3 | 3 |
5 | 13 | 1937.32 | 37 | 11.59 | 3089 | 1325 | 3.28 / 904.34 | 3 | 3 |
6 | 13 | 1541.04 | 37 | 12.41 | 2578 | 1184 | 4.46 / 905.53 | 3 | 5 |
7 | 13 | 470.08 | 37 | 13.44 | 1081 | 538 | 5.00 / 906.07 | 3 | 10 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 33 | 13.70 | 632 | 286 | 0.29 / 896.26 | 3 | 6 |
2 | 10 | 1012.04 | 3 | 13.18 | 1873 | 74 | 0.36 / 896.33 | 3 | 6 |
3 | 3 | 974.64 | -1 | 13.18 | 1873 | 0 | 0.07 / 896.33 | 3 | 6 |
4 | 12 | 2004.76 | 34 | 7.93 | 2945 | 794 | 1.15 / 897.13 | 3 | 3 |
5 | 7 | 2006.84 | 25 | 10.32 | 3184 | 821 | 1.98 / 897.95 | 3 | 3 |
6 | 13 | 1938.00 | 37 | 11.64 | 3116 | 1342 | 3.32 / 899.29 | 3 | 3 |
7 | 13 | 1677.48 | 37 | 12.29 | 2754 | 1252 | 4.57 / 900.54 | 3 | 4 |
8 | 13 | 448.60 | 37 | 13.47 | 1051 | 524 | 5.09 / 901.07 | 3 | 10 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 34 | 13.70 | 639 | 298 | 0.30 / 891.33 | 3 | 7 |
2 | 3 | 940.68 | -2 | 13.70 | 639 | 0 | 0.00 / 891.33 | 3 | 7 |
3 | 12 | 2014.40 | 34 | 8.34 | 2990 | 848 | 1.15 / 892.18 | 3 | 3 |
4 | 7 | 2016.28 | 25 | 10.36 | 3170 | 821 | 1.97 / 893.00 | 3 | 3 |
5 | 13 | 1936.92 | 37 | 11.63 | 3110 | 1338 | 3.30 / 894.34 | 3 | 3 |
6 | 13 | 1397.76 | 37 | 12.56 | 2363 | 1098 | 4.40 / 895.44 | 3 | 5 |
7 | 13 | 472.76 | 37 | 13.45 | 1078 | 536 | 4.94 / 895.97 | 3 | 10 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 35 | 13.69 | 641 | 307 | 0.31 / 886.54 | 3 | 7 |
2 | 3 | 978.36 | -1 | 13.69 | 641 | 0 | 0.00 / 886.54 | 3 | 7 |
3 | 12 | 2004.84 | 34 | 7.81 | 2911 | 773 | 1.08 / 887.31 | 3 | 3 |
4 | 7 | 2006.96 | 25 | 10.37 | 3193 | 828 | 1.91 / 888.14 | 3 | 3 |
5 | 13 | 1938.24 | 37 | 11.73 | 3130 | 1358 | 3.27 / 889.50 | 3 | 3 |
6 | 13 | 1536.48 | 37 | 12.44 | 2561 | 1179 | 4.45 / 890.67 | 3 | 5 |
7 | 13 | 351.72 | 7 | 13.68 | 950 | 91 | 4.54 / 890.77 | 3 | 9 |
8 | 13 | 230.08 | 5 | 13.72 | 800 | 55 | 4.59 / 890.82 | 3 | 9 |
9 | 13 | 144.48 | 5 | 13.78 | 691 | 48 | 4.64 / 890.87 | 3 | 8 |
10 | 13 | 91.84 | 5 | 13.80 | 630 | 43 | 4.68 / 890.91 | 3 | 7 |
11 | 13 | 67.76 | 5 | 13.83 | 597 | 41 | 4.72 / 890.95 | 3 | 6 |
12 | 13 | 54.60 | 5 | 13.80 | 589 | 41 | 4.76 / 890.99 | 3 | 7 |
13 | 13 | 47.04 | 5 | 13.82 | 579 | 40 | 4.80 / 891.03 | 3 | 7 |
Average= | 4.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 34 | 13.73 | 652 | 304 | 0.30 / 881.53 | 3 | 6 |
2 | 12 | 2004.16 | 34 | 7.88 | 2919 | 782 | 1.09 / 882.31 | 3 | 3 |
3 | 7 | 2006.48 | 25 | 10.46 | 3179 | 831 | 1.92 / 883.14 | 3 | 3 |
4 | 13 | 1937.48 | 37 | 11.79 | 3111 | 1357 | 3.27 / 884.50 | 3 | 3 |
5 | 13 | 1532.64 | 37 | 12.45 | 2579 | 1188 | 4.46 / 885.69 | 3 | 5 |
6 | 13 | 462.52 | 37 | 13.45 | 1089 | 542 | 5.00 / 886.23 | 3 | 11 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 34 | 13.71 | 635 | 296 | 0.30 / 876.40 | 3 | 5 |
2 | 12 | 2014.08 | 34 | 7.74 | 2973 | 782 | 1.08 / 877.19 | 3 | 3 |
3 | 7 | 2017.08 | 25 | 10.39 | 3198 | 831 | 1.91 / 878.02 | 3 | 3 |
4 | 13 | 1958.44 | 37 | 11.69 | 3163 | 1368 | 3.28 / 879.38 | 3 | 3 |
5 | 13 | 1433.48 | 37 | 12.52 | 2418 | 1120 | 4.40 / 880.51 | 3 | 5 |
6 | 13 | 691.04 | 37 | 13.26 | 1385 | 680 | 5.08 / 881.18 | 3 | 10 |
7 | 13 | 59.52 | 5 | 13.85 | 572 | 40 | 5.12 / 881.22 | 3 | 6 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 34 | 13.72 | 639 | 298 | 0.30 / 871.37 | 3 | 6 |
2 | 12 | 2004.08 | 34 | 7.79 | 2925 | 775 | 1.07 / 872.15 | 3 | 3 |
3 | 7 | 2006.24 | 25 | 10.47 | 3183 | 833 | 1.91 / 872.98 | 3 | 3 |
4 | 13 | 1930.76 | 37 | 11.80 | 3107 | 1357 | 3.26 / 874.34 | 3 | 3 |
5 | 13 | 1655.40 | 37 | 12.29 | 2743 | 1247 | 4.51 / 875.59 | 3 | 4 |
6 | 13 | 430.92 | 37 | 13.47 | 1046 | 521 | 5.03 / 876.11 | 3 | 11 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 34 | 13.72 | 640 | 299 | 0.30 / 866.37 | 3 | 6 |
2 | 12 | 2018.80 | 34 | 7.71 | 2897 | 759 | 1.06 / 867.13 | 3 | 3 |
3 | 7 | 2021.12 | 25 | 10.44 | 3205 | 837 | 1.89 / 867.97 | 3 | 3 |
4 | 13 | 1950.92 | 37 | 11.78 | 3150 | 1373 | 3.27 / 869.34 | 3 | 3 |
5 | 13 | 1536.00 | 37 | 12.43 | 2593 | 1193 | 4.46 / 870.53 | 3 | 5 |
6 | 13 | 468.48 | 37 | 13.45 | 1090 | 542 | 5.00 / 871.08 | 3 | 11 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 35 | 13.73 | 636 | 306 | 0.31 / 861.39 | 3 | 6 |
2 | 3 | 966.48 | -1 | 13.73 | 636 | 0 | 0.00 / 861.39 | 3 | 6 |
3 | 12 | 2004.40 | 34 | 7.67 | 2870 | 748 | 1.05 / 862.14 | 3 | 3 |
4 | 7 | 2006.68 | 25 | 10.53 | 3205 | 844 | 1.90 / 862.99 | 3 | 3 |
5 | 13 | 1934.12 | 37 | 11.83 | 3129 | 1370 | 3.27 / 864.36 | 3 | 3 |
6 | 13 | 1526.60 | 37 | 12.50 | 2543 | 1176 | 4.44 / 865.53 | 3 | 5 |
7 | 13 | 459.88 | 37 | 13.47 | 1089 | 543 | 4.99 / 866.07 | 3 | 11 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 33 | 13.76 | 628 | 285 | 0.29 / 856.27 | 3 | 5 |
2 | 10 | 1020.40 | 3 | 13.19 | 1912 | 76 | 0.36 / 856.35 | 3 | 6 |
3 | 12 | 2017.96 | 34 | 7.81 | 2922 | 776 | 1.14 / 857.12 | 3 | 3 |
4 | 7 | 2019.96 | 25 | 10.57 | 3219 | 851 | 1.99 / 857.97 | 3 | 3 |
5 | 13 | 1941.96 | 37 | 11.92 | 3146 | 1388 | 3.37 / 859.36 | 3 | 3 |
6 | 13 | 1537.92 | 37 | 12.49 | 2571 | 1188 | 4.56 / 860.55 | 3 | 5 |
7 | 13 | 463.04 | 37 | 13.49 | 1078 | 538 | 5.10 / 861.09 | 3 | 10 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 32 | 13.73 | 663 | 291 | 0.29 / 851.20 | 3 | 7 |
2 | 12 | 2017.20 | 34 | 8.64 | 2979 | 875 | 1.17 / 852.07 | 3 | 3 |
3 | 7 | 2018.56 | 25 | 10.72 | 3195 | 856 | 2.02 / 852.93 | 3 | 3 |
4 | 13 | 1929.92 | 37 | 11.99 | 3084 | 1368 | 3.39 / 854.30 | 3 | 3 |
5 | 13 | 1519.04 | 37 | 12.54 | 2549 | 1183 | 4.57 / 855.48 | 3 | 5 |
6 | 13 | 414.36 | 37 | 13.52 | 1014 | 507 | 5.08 / 855.99 | 3 | 10 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 32 | 13.76 | 659 | 290 | 0.29 / 846.46 | 3 | 7 |
2 | 12 | 2004.20 | 34 | 8.60 | 2953 | 863 | 1.15 / 847.32 | 3 | 3 |
3 | 7 | 2005.96 | 25 | 10.76 | 3197 | 860 | 2.01 / 848.18 | 3 | 3 |
4 | 13 | 1923.44 | 37 | 12.01 | 3099 | 1377 | 3.39 / 849.56 | 3 | 3 |
5 | 13 | 1365.08 | 37 | 12.69 | 2329 | 1094 | 4.48 / 850.65 | 3 | 6 |
6 | 13 | 295.80 | 6 | 13.70 | 888 | 73 | 4.56 / 850.73 | 3 | 10 |
7 | 13 | 167.96 | 5 | 13.80 | 726 | 50 | 4.61 / 850.78 | 3 | 8 |
8 | 13 | 98.12 | 5 | 13.84 | 647 | 45 | 4.65 / 850.82 | 3 | 8 |
9 | 13 | 73.88 | 5 | 13.87 | 621 | 43 | 4.70 / 850.86 | 3 | 7 |
10 | 13 | 56.88 | 5 | 13.82 | 599 | 41 | 4.74 / 850.91 | 3 | 7 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 42 | 13.71 | 650 | 374 | 0.37 / 841.78 | 3 | 9 |
2 | 3 | 677.52 | -8 | 13.71 | 650 | 0 | 0.00 / 841.78 | 3 | 9 |
3 | 3 | 909.20 | -2 | 13.71 | 650 | 0 | 0.00 / 841.78 | 3 | 9 |
4 | 12 | 2004.24 | 34 | 8.77 | 2989 | 891 | 1.27 / 842.67 | 3 | 3 |
5 | 7 | 2005.72 | 25 | 10.91 | 3199 | 873 | 2.14 / 843.54 | 3 | 3 |
6 | 13 | 1915.60 | 37 | 12.12 | 3107 | 1393 | 3.53 / 844.93 | 3 | 3 |
7 | 13 | 1218.36 | 37 | 12.85 | 2137 | 1016 | 4.55 / 845.95 | 3 | 7 |
8 | 13 | 172.40 | 5 | 13.77 | 715 | 49 | 4.60 / 846.00 | 3 | 9 |
9 | 13 | 109.92 | 5 | 13.84 | 656 | 45 | 4.64 / 846.04 | 3 | 8 |
10 | 13 | 79.96 | 5 | 13.85 | 625 | 43 | 4.69 / 846.09 | 3 | 8 |
11 | 13 | 62.88 | 5 | 13.84 | 604 | 42 | 4.73 / 846.13 | 3 | 7 |
12 | 13 | 51.84 | 5 | 13.83 | 596 | 41 | 4.77 / 846.17 | 3 | 7 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 44 | 13.63 | 654 | 392 | 0.39 / 836.99 | 3 | 10 |
2 | 3 | 898.28 | -3 | 13.63 | 654 | 0 | 0.00 / 836.99 | 3 | 10 |
3 | 12 | 2004.64 | 34 | 9.66 | 3060 | 1005 | 1.40 / 837.99 | 3 | 3 |
4 | 7 | 2005.12 | 25 | 11.08 | 3183 | 882 | 2.28 / 838.87 | 3 | 3 |
5 | 13 | 1907.64 | 37 | 12.24 | 3070 | 1390 | 3.67 / 840.26 | 3 | 4 |
6 | 13 | 1201.40 | 37 | 12.88 | 2093 | 997 | 4.67 / 841.26 | 3 | 8 |
7 | 13 | 247.92 | 5 | 13.75 | 823 | 57 | 4.72 / 841.32 | 3 | 10 |
8 | 13 | 90.08 | 5 | 13.82 | 644 | 45 | 4.77 / 841.36 | 3 | 8 |
9 | 13 | 50.80 | 5 | 13.86 | 583 | 40 | 4.81 / 841.40 | 3 | 7 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 34 | 13.75 | 640 | 299 | 0.30 / 831.35 | 3 | 6 |
2 | 3 | 979.16 | -1 | 13.75 | 640 | 0 | 0.00 / 831.35 | 3 | 6 |
3 | 12 | 1522.64 | 34 | 12.42 | 2578 | 1089 | 1.39 / 832.44 | 3 | 3 |
4 | 7 | 1524.48 | 25 | 11.85 | 2562 | 759 | 2.15 / 833.20 | 3 | 3 |
5 | 13 | 1422.96 | 37 | 12.67 | 2405 | 1127 | 3.27 / 834.32 | 3 | 5 |
6 | 13 | 694.56 | 37 | 13.29 | 1394 | 685 | 3.96 / 835.01 | 3 | 11 |
7 | 13 | 58.36 | 5 | 13.84 | 567 | 39 | 4.00 / 835.05 | 3 | 8 |
8 | 13 | 2.48 | 37 | 13.89 | 524 | 269 | 4.27 / 835.32 | 3 | 6 |
9 | 8 | 0.12 | 190 | 13.49 | 498 | 1276 | 5.54 / 836.59 | 3 | 10 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 42 | 13.69 | 637 | 366 | 0.37 / 827.35 | 3 | 8 |
2 | 3 | 747.84 | -7 | 13.69 | 637 | 0 | 0.00 / 827.35 | 3 | 8 |
3 | 3 | 949.80 | -1 | 13.69 | 637 | 0 | 0.00 / 827.35 | 3 | 8 |
4 | 12 | 1519.44 | 34 | 12.38 | 2567 | 1081 | 1.45 / 828.44 | 3 | 3 |
5 | 7 | 1520.92 | 25 | 11.83 | 2576 | 762 | 2.21 / 829.20 | 3 | 4 |
6 | 13 | 1414.00 | 37 | 12.65 | 2420 | 1133 | 3.34 / 830.33 | 3 | 6 |
7 | 13 | 675.20 | 37 | 13.31 | 1378 | 679 | 4.02 / 831.01 | 3 | 11 |
8 | 13 | 58.36 | 5 | 13.85 | 581 | 40 | 4.06 / 831.05 | 3 | 8 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 27 | 13.77 | 651 | 242 | 0.24 / 823.02 | 3 | 4 |
2 | 10 | 1015.16 | 6 | 13.32 | 1881 | 150 | 0.39 / 823.17 | 3 | 5 |
3 | 10 | 1060.84 | 4 | 13.46 | 1932 | 104 | 0.50 / 823.28 | 3 | 6 |
4 | 3 | 1134.20 | 3 | 13.08 | 2091 | 82 | 0.58 / 823.36 | 3 | 6 |
5 | 3 | 1031.68 | 1 | 12.61 | 1929 | 24 | 0.60 / 823.38 | 3 | 3 |
6 | 12 | 1523.24 | 34 | 12.31 | 2561 | 1072 | 1.67 / 824.45 | 3 | 3 |
7 | 7 | 1524.76 | 25 | 11.82 | 2567 | 759 | 2.43 / 825.21 | 3 | 3 |
8 | 13 | 1424.24 | 37 | 12.66 | 2408 | 1128 | 3.56 / 826.34 | 3 | 5 |
9 | 13 | 560.16 | 37 | 13.40 | 1227 | 608 | 4.17 / 826.95 | 3 | 11 |
10 | 13 | 51.72 | 5 | 13.86 | 571 | 40 | 4.21 / 826.99 | 3 | 7 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 28 | 13.73 | 674 | 259 | 0.26 / 816.34 | 3 | 4 |
2 | 10 | 1056.24 | 6 | 13.32 | 1896 | 152 | 0.41 / 816.49 | 3 | 4 |
3 | 10 | 1102.64 | 4 | 13.47 | 1993 | 107 | 0.52 / 816.59 | 3 | 5 |
4 | 3 | 1205.76 | 5 | 13.04 | 2186 | 143 | 0.66 / 816.74 | 3 | 6 |
5 | 3 | 1046.88 | 1 | 12.82 | 1949 | 25 | 0.69 / 816.76 | 3 | 3 |
6 | 12 | 2013.76 | 34 | 8.14 | 2939 | 813 | 1.50 / 817.58 | 3 | 3 |
7 | 7 | 2015.96 | 24 | 10.88 | 3214 | 839 | 2.34 / 818.41 | 3 | 3 |
8 | 13 | 1942.64 | 37 | 12.00 | 3132 | 1391 | 3.73 / 819.81 | 3 | 3 |
9 | 13 | 1394.36 | 37 | 12.67 | 2366 | 1109 | 4.84 / 820.91 | 3 | 6 |
10 | 13 | 332.76 | 7 | 13.69 | 938 | 90 | 4.93 / 821.00 | 3 | 9 |
11 | 13 | 211.92 | 5 | 13.76 | 794 | 55 | 4.98 / 821.06 | 3 | 9 |
12 | 13 | 122.20 | 5 | 13.82 | 676 | 47 | 5.03 / 821.11 | 3 | 8 |
13 | 13 | 80.80 | 5 | 13.81 | 627 | 43 | 5.07 / 821.15 | 3 | 7 |
14 | 13 | 60.44 | 5 | 13.83 | 605 | 42 | 5.11 / 821.19 | 3 | 7 |
15 | 13 | 50.08 | 5 | 13.80 | 588 | 41 | 5.15 / 821.23 | 3 | 7 |
16 | 13 | 3.88 | 37 | 13.88 | 528 | 271 | 5.43 / 821.50 | 3 | 6 |
17 | 8 | -0.36 | 190 | 13.49 | 498 | 1276 | 6.70 / 822.78 | 3 | 10 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 28 | 13.79 | 639 | 247 | 0.25 / 810.63 | 3 | 3 |
2 | 3 | 979.72 | -1 | 13.79 | 639 | 0 | 0.00 / 810.63 | 3 | 3 |
3 | 3 | 1020.28 | 1 | 12.48 | 1907 | 24 | 0.27 / 810.66 | 3 | 3 |
4 | 12 | 2001.40 | 34 | 8.26 | 2899 | 814 | 1.08 / 811.47 | 3 | 3 |
5 | 7 | 1999.48 | 25 | 10.71 | 3155 | 845 | 1.93 / 812.32 | 3 | 3 |
6 | 13 | 1872.28 | 37 | 11.98 | 3036 | 1346 | 3.28 / 813.66 | 3 | 3 |
7 | 13 | 945.28 | 37 | 13.04 | 1735 | 837 | 4.11 / 814.50 | 3 | 8 |
8 | 13 | 68.12 | 37 | 13.81 | 585 | 299 | 4.41 / 814.80 | 3 | 8 |
9 | 8 | 0.80 | 190 | 13.55 | 497 | 1280 | 5.69 / 816.08 | 3 | 11 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 28 | 13.77 | 626 | 241 | 0.24 / 805.03 | 3 | 3 |
2 | 12 | 2004.00 | 34 | 7.63 | 2878 | 747 | 0.99 / 805.78 | 3 | 3 |
3 | 7 | 2002.40 | 25 | 10.55 | 3173 | 837 | 1.82 / 806.62 | 3 | 3 |
4 | 13 | 1880.80 | 37 | 11.90 | 3043 | 1340 | 3.16 / 807.96 | 3 | 3 |
5 | 13 | 971.84 | 37 | 13.02 | 1751 | 844 | 4.01 / 808.80 | 3 | 7 |
6 | 13 | 81.28 | 37 | 13.81 | 593 | 303 | 4.31 / 809.10 | 3 | 8 |
7 | 8 | 0.08 | 190 | 13.56 | 498 | 1283 | 5.59 / 810.39 | 3 | 8 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 25 | 13.78 | 645 | 222 | 0.22 / 799.23 | 3 | 3 |
2 | 3 | 1083.28 | 2 | 12.92 | 1974 | 51 | 0.27 / 799.28 | 3 | 3 |
3 | 3 | 1023.24 | 1 | 12.41 | 1889 | 23 | 0.30 / 799.30 | 3 | 3 |
4 | 12 | 2004.68 | 34 | 7.74 | 2889 | 760 | 1.06 / 800.07 | 3 | 3 |
5 | 7 | 2003.08 | 25 | 10.58 | 3181 | 841 | 1.90 / 800.91 | 3 | 3 |
6 | 13 | 1885.40 | 37 | 11.94 | 3061 | 1352 | 3.25 / 802.26 | 3 | 3 |
7 | 13 | 1120.88 | 37 | 12.89 | 1993 | 951 | 4.20 / 803.21 | 3 | 8 |
8 | 13 | 71.96 | 37 | 13.81 | 589 | 301 | 4.50 / 803.51 | 3 | 9 |
9 | 8 | -0.04 | 190 | 13.57 | 497 | 1281 | 5.78 / 804.79 | 3 | 13 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 14 | 13.86 | 640 | 124 | 0.12 / 793.42 | 3 | 3 |
2 | 10 | 1026.76 | 6 | 13.21 | 1900 | 151 | 0.27 / 793.57 | 3 | 3 |
3 | 10 | 1062.68 | 3 | 13.48 | 1941 | 78 | 0.35 / 793.65 | 3 | 3 |
4 | 3 | 1054.12 | 1 | 12.83 | 1969 | 25 | 0.38 / 793.67 | 3 | 3 |
5 | 12 | 2003.36 | 34 | 7.28 | 2912 | 721 | 1.10 / 794.39 | 3 | 3 |
6 | 7 | 2002.24 | 25 | 10.53 | 3171 | 835 | 1.93 / 795.23 | 3 | 3 |
7 | 13 | 1887.32 | 37 | 11.89 | 3067 | 1349 | 3.28 / 796.58 | 3 | 3 |
8 | 13 | 1164.24 | 37 | 12.86 | 2037 | 969 | 4.25 / 797.55 | 3 | 7 |
9 | 13 | 117.24 | 5 | 13.77 | 660 | 45 | 4.30 / 797.59 | 3 | 8 |
10 | 13 | 80.44 | 5 | 13.80 | 629 | 43 | 4.34 / 797.64 | 3 | 8 |
11 | 13 | 59.80 | 5 | 13.83 | 604 | 42 | 4.38 / 797.68 | 3 | 7 |
12 | 13 | 49.48 | 5 | 13.81 | 595 | 41 | 4.42 / 797.72 | 3 | 7 |
13 | 8 | 0.16 | 190 | 13.57 | 500 | 1289 | 5.71 / 799.01 | 3 | 12 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 13 | 13.89 | 654 | 118 | 0.12 / 787.46 | 3 | 3 |
2 | 3 | 1030.56 | 1 | 12.55 | 1934 | 24 | 0.14 / 787.49 | 3 | 3 |
3 | 12 | 2003.04 | 34 | 7.56 | 2871 | 738 | 0.88 / 788.22 | 3 | 3 |
4 | 7 | 2001.20 | 25 | 10.33 | 3182 | 822 | 1.70 / 789.05 | 3 | 3 |
5 | 13 | 1878.40 | 37 | 11.67 | 3043 | 1314 | 3.02 / 790.36 | 3 | 3 |
6 | 13 | 1149.44 | 37 | 12.80 | 2023 | 958 | 3.97 / 791.32 | 3 | 7 |
7 | 13 | 115.48 | 5 | 13.78 | 642 | 44 | 4.02 / 791.36 | 3 | 7 |
8 | 13 | 74.80 | 5 | 13.80 | 610 | 42 | 4.06 / 791.40 | 3 | 6 |
9 | 13 | 48.60 | 5 | 13.82 | 588 | 41 | 4.10 / 791.45 | 3 | 6 |
10 | 13 | 44.76 | 5 | 13.83 | 578 | 40 | 4.14 / 791.49 | 3 | 6 |
11 | 13 | 42.04 | 5 | 13.83 | 575 | 40 | 4.18 / 791.53 | 3 | 7 |
12 | 13 | 17.16 | 37 | 13.85 | 536 | 275 | 4.46 / 791.80 | 3 | 6 |
13 | 13 | 4.08 | 37 | 13.78 | 508 | 259 | 4.71 / 792.06 | 3 | 8 |
14 | 8 | 0.12 | 190 | 13.47 | 483 | 1236 | 5.95 / 793.29 | 3 | 13 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 13 | 13.85 | 662 | 119 | 0.12 / 783.32 | 3 | 3 |
2 | 12 | 2003.12 | 34 | 7.43 | 2926 | 739 | 0.86 / 784.06 | 3 | 3 |
3 | 7 | 2001.96 | 25 | 10.38 | 3190 | 828 | 1.69 / 784.89 | 3 | 3 |
4 | 13 | 1888.96 | 37 | 11.69 | 3058 | 1323 | 3.01 / 786.21 | 3 | 3 |
5 | 13 | 1158.16 | 37 | 12.79 | 2040 | 965 | 3.97 / 787.18 | 3 | 7 |
6 | 13 | 110.64 | 5 | 13.80 | 640 | 44 | 4.02 / 787.22 | 3 | 7 |
7 | 13 | 76.48 | 5 | 13.79 | 616 | 42 | 4.06 / 787.26 | 3 | 7 |
8 | 13 | 57.16 | 5 | 13.81 | 600 | 41 | 4.10 / 787.30 | 3 | 7 |
9 | 13 | 40.28 | 5 | 13.82 | 575 | 40 | 4.14 / 787.34 | 3 | 6 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 13 | 13.84 | 666 | 120 | 0.12 / 779.22 | 3 | 3 |
2 | 12 | 2002.76 | 34 | 7.25 | 2951 | 727 | 0.85 / 779.94 | 3 | 3 |
3 | 7 | 2001.56 | 25 | 10.43 | 3180 | 829 | 1.68 / 780.77 | 3 | 3 |
4 | 13 | 1886.24 | 37 | 11.75 | 3062 | 1331 | 3.01 / 782.10 | 3 | 3 |
5 | 13 | 1160.76 | 37 | 12.79 | 2050 | 970 | 3.98 / 783.07 | 3 | 7 |
6 | 13 | 111.64 | 5 | 13.78 | 648 | 45 | 4.02 / 783.12 | 3 | 8 |
7 | 13 | 82.48 | 5 | 13.78 | 628 | 43 | 4.07 / 783.16 | 3 | 7 |
8 | 13 | 61.48 | 5 | 13.81 | 595 | 41 | 4.11 / 783.20 | 3 | 6 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 13 | 13.84 | 662 | 119 | 0.12 / 775.09 | 3 | 3 |
2 | 12 | 2005.04 | 34 | 7.54 | 2917 | 748 | 0.87 / 775.84 | 3 | 3 |
3 | 7 | 2003.52 | 25 | 10.53 | 3174 | 836 | 1.70 / 776.67 | 3 | 3 |
4 | 13 | 1886.40 | 37 | 11.80 | 3070 | 1340 | 3.04 / 778.01 | 3 | 3 |
5 | 13 | 1144.72 | 37 | 12.81 | 2013 | 954 | 4.00 / 778.97 | 3 | 7 |
6 | 13 | 101.48 | 5 | 13.77 | 637 | 44 | 4.04 / 779.01 | 3 | 7 |
7 | 13 | 71.16 | 5 | 13.80 | 629 | 43 | 4.08 / 779.05 | 3 | 8 |
8 | 13 | 43.20 | 5 | 13.83 | 591 | 41 | 4.13 / 779.10 | 3 | 7 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 14 | 13.88 | 647 | 126 | 0.13 / 771.05 | 3 | 3 |
2 | 3 | 966.20 | -1 | 13.88 | 647 | 0 | 0.00 / 771.05 | 3 | 3 |
3 | 12 | 2001.68 | 34 | 7.42 | 2902 | 732 | 0.86 / 771.79 | 3 | 3 |
4 | 7 | 2000.68 | 25 | 10.49 | 3174 | 832 | 1.69 / 772.62 | 3 | 3 |
5 | 13 | 1887.44 | 37 | 11.80 | 3059 | 1336 | 3.03 / 773.95 | 3 | 3 |
6 | 13 | 1026.16 | 37 | 12.92 | 1850 | 884 | 3.91 / 774.84 | 3 | 8 |
7 | 13 | 124.88 | 5 | 13.78 | 670 | 46 | 3.96 / 774.88 | 3 | 7 |
8 | 13 | 81.16 | 5 | 13.80 | 631 | 44 | 4.00 / 774.93 | 3 | 8 |
9 | 13 | 59.08 | 5 | 13.80 | 613 | 42 | 4.04 / 774.97 | 3 | 7 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 14 | 13.83 | 671 | 130 | 0.13 / 767.07 | 3 | 3 |
2 | 12 | 2002.44 | 34 | 7.53 | 2856 | 731 | 0.86 / 767.80 | 3 | 3 |
3 | 7 | 2000.64 | 25 | 10.51 | 3177 | 835 | 1.70 / 768.64 | 3 | 3 |
4 | 13 | 1879.80 | 37 | 11.81 | 3058 | 1336 | 3.03 / 769.98 | 3 | 3 |
5 | 13 | 1009.56 | 37 | 12.97 | 1816 | 871 | 3.90 / 770.85 | 3 | 7 |
6 | 13 | 75.24 | 5 | 13.83 | 588 | 41 | 3.94 / 770.89 | 3 | 6 |
7 | 13 | 56.40 | 5 | 13.84 | 587 | 41 | 3.98 / 770.93 | 3 | 6 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 14 | 13.85 | 663 | 129 | 0.13 / 762.95 | 3 | 3 |
2 | 12 | 2003.12 | 34 | 7.63 | 2845 | 738 | 0.87 / 763.69 | 3 | 3 |
3 | 7 | 2001.40 | 25 | 10.53 | 3186 | 839 | 1.71 / 764.53 | 3 | 3 |
4 | 13 | 1881.60 | 37 | 11.82 | 3056 | 1337 | 3.04 / 765.87 | 3 | 3 |
5 | 13 | 1130.88 | 37 | 12.83 | 2013 | 956 | 4.00 / 766.82 | 3 | 7 |
6 | 13 | 64.88 | 5 | 13.82 | 580 | 40 | 4.04 / 766.86 | 3 | 6 |
7 | 13 | 52.44 | 5 | 13.81 | 592 | 41 | 4.08 / 766.90 | 3 | 6 |
8 | 13 | 42.64 | 5 | 13.81 | 581 | 40 | 4.12 / 766.94 | 3 | 6 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 14 | 13.83 | 672 | 130 | 0.13 / 758.89 | 3 | 3 |
2 | 12 | 2002.96 | 34 | 7.62 | 2871 | 744 | 0.87 / 759.63 | 3 | 3 |
3 | 7 | 2001.56 | 25 | 10.56 | 3180 | 840 | 1.71 / 760.47 | 3 | 3 |
4 | 13 | 1887.00 | 37 | 11.84 | 3062 | 1341 | 3.05 / 761.82 | 3 | 3 |
5 | 13 | 1021.12 | 37 | 12.95 | 1838 | 881 | 3.94 / 762.70 | 3 | 7 |
6 | 13 | 122.36 | 5 | 13.80 | 655 | 45 | 3.98 / 762.74 | 3 | 7 |
7 | 13 | 81.08 | 5 | 13.83 | 618 | 43 | 4.02 / 762.78 | 3 | 7 |
8 | 13 | 40.44 | 5 | 13.84 | 590 | 41 | 4.06 / 762.82 | 3 | 7 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 14 | 13.88 | 661 | 128 | 0.13 / 754.84 | 3 | 3 |
2 | 12 | 2003.12 | 34 | 7.84 | 2877 | 767 | 0.90 / 755.60 | 3 | 3 |
3 | 7 | 2001.36 | 25 | 10.59 | 3180 | 842 | 1.74 / 756.45 | 3 | 3 |
4 | 13 | 1880.36 | 37 | 11.86 | 3070 | 1347 | 3.08 / 757.79 | 3 | 3 |
5 | 13 | 1002.80 | 37 | 12.95 | 1845 | 884 | 3.97 / 758.68 | 3 | 8 |
6 | 13 | 70.60 | 5 | 13.83 | 605 | 42 | 4.01 / 758.72 | 3 | 6 |
7 | 13 | 54.80 | 5 | 13.83 | 598 | 41 | 4.05 / 758.76 | 3 | 7 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 15 | 13.88 | 664 | 138 | 0.14 / 750.76 | 3 | 4 |
2 | 3 | 969.32 | -1 | 13.88 | 664 | 0 | 0.00 / 750.76 | 3 | 4 |
3 | 12 | 2004.84 | 34 | 7.92 | 2896 | 780 | 0.92 / 751.54 | 3 | 3 |
4 | 7 | 2002.92 | 25 | 10.64 | 3176 | 845 | 1.76 / 752.38 | 3 | 3 |
5 | 13 | 1879.96 | 37 | 11.91 | 3065 | 1351 | 3.11 / 753.73 | 3 | 3 |
6 | 13 | 990.20 | 37 | 13.00 | 1780 | 856 | 3.97 / 754.59 | 3 | 7 |
7 | 13 | 71.96 | 5 | 13.83 | 584 | 40 | 4.01 / 754.63 | 3 | 6 |
8 | 13 | 55.76 | 5 | 13.84 | 598 | 41 | 4.05 / 754.67 | 3 | 7 |
9 | 13 | 40.16 | 5 | 13.85 | 582 | 40 | 4.09 / 754.71 | 3 | 6 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 14 | 13.86 | 667 | 129 | 0.13 / 746.63 | 3 | 3 |
2 | 3 | 1021.60 | 1 | 12.38 | 1904 | 24 | 0.15 / 746.65 | 3 | 3 |
3 | 12 | 2004.60 | 34 | 8.05 | 2954 | 809 | 0.96 / 747.46 | 3 | 3 |
4 | 7 | 2002.80 | 25 | 10.62 | 3183 | 845 | 1.81 / 748.31 | 3 | 3 |
5 | 13 | 1881.92 | 37 | 11.96 | 3061 | 1355 | 3.16 / 749.66 | 3 | 3 |
6 | 13 | 988.12 | 37 | 12.98 | 1812 | 870 | 4.03 / 750.53 | 3 | 8 |
7 | 13 | 100.08 | 5 | 13.82 | 643 | 44 | 4.08 / 750.58 | 3 | 7 |
8 | 13 | 68.76 | 5 | 13.84 | 608 | 42 | 4.12 / 750.62 | 3 | 6 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 13 | 13.86 | 662 | 119 | 0.12 / 742.53 | 3 | 3 |
2 | 3 | 1018.92 | 1 | 12.35 | 1909 | 24 | 0.14 / 742.55 | 3 | 3 |
3 | 12 | 2004.92 | 34 | 8.13 | 2952 | 816 | 0.96 / 743.37 | 3 | 3 |
4 | 7 | 2003.08 | 25 | 10.65 | 3174 | 845 | 1.80 / 744.22 | 3 | 3 |
5 | 13 | 1881.32 | 37 | 11.95 | 3039 | 1344 | 3.15 / 745.56 | 3 | 3 |
6 | 13 | 982.88 | 37 | 12.99 | 1780 | 856 | 4.00 / 746.41 | 3 | 8 |
7 | 13 | 96.60 | 5 | 13.83 | 615 | 43 | 4.05 / 746.46 | 3 | 7 |
8 | 13 | 67.48 | 5 | 13.84 | 607 | 42 | 4.09 / 746.50 | 3 | 7 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 13 | 13.87 | 659 | 119 | 0.12 / 738.37 | 3 | 3 |
2 | 12 | 2000.68 | 34 | 8.25 | 2914 | 817 | 0.94 / 739.19 | 3 | 3 |
3 | 7 | 1998.68 | 25 | 10.62 | 3164 | 840 | 1.78 / 740.03 | 3 | 3 |
4 | 13 | 1872.24 | 37 | 11.92 | 3040 | 1341 | 3.12 / 741.37 | 3 | 3 |
5 | 13 | 1103.72 | 37 | 12.88 | 1974 | 941 | 4.06 / 742.31 | 3 | 7 |
6 | 13 | 275.44 | 5 | 13.74 | 872 | 60 | 4.12 / 742.37 | 3 | 9 |
7 | 13 | 81.52 | 5 | 13.83 | 626 | 43 | 4.16 / 742.41 | 3 | 7 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 15 | 13.86 | 665 | 138 | 0.14 / 734.31 | 3 | 4 |
2 | 3 | 942.92 | -1 | 13.86 | 665 | 0 | 0.00 / 734.31 | 3 | 4 |
3 | 3 | 974.60 | -1 | 13.86 | 665 | 0 | 0.00 / 734.31 | 3 | 4 |
4 | 12 | 2005.16 | 34 | 8.28 | 2916 | 821 | 0.96 / 735.13 | 3 | 3 |
5 | 7 | 2003.20 | 25 | 10.58 | 3178 | 841 | 1.80 / 735.97 | 3 | 3 |
6 | 13 | 1880.96 | 37 | 11.92 | 3060 | 1350 | 3.15 / 737.32 | 3 | 3 |
7 | 13 | 980.16 | 37 | 13.02 | 1765 | 850 | 4.00 / 738.17 | 3 | 7 |
8 | 13 | 89.80 | 5 | 13.84 | 607 | 42 | 4.04 / 738.21 | 3 | 7 |
9 | 13 | 44.72 | 5 | 13.85 | 580 | 40 | 4.08 / 738.25 | 3 | 6 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 14 | 13.89 | 664 | 129 | 0.13 / 730.16 | 3 | 3 |
2 | 3 | 1031.96 | 1 | 12.65 | 1915 | 24 | 0.15 / 730.18 | 3 | 3 |
3 | 12 | 2001.56 | 34 | 8.48 | 2980 | 859 | 1.01 / 731.04 | 3 | 3 |
4 | 7 | 1999.36 | 25 | 10.63 | 3208 | 853 | 1.87 / 731.89 | 3 | 3 |
5 | 13 | 1873.60 | 37 | 11.99 | 3027 | 1343 | 3.21 / 733.24 | 3 | 3 |
6 | 13 | 965.52 | 37 | 13.02 | 1764 | 850 | 4.06 / 734.09 | 3 | 8 |
7 | 13 | 82.28 | 5 | 13.86 | 609 | 42 | 4.10 / 734.13 | 3 | 7 |
8 | 13 | 44.40 | 5 | 13.85 | 582 | 40 | 4.14 / 734.17 | 3 | 6 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 15 | 13.87 | 658 | 137 | 0.14 / 725.98 | 3 | 4 |
2 | 3 | 975.60 | -1 | 13.87 | 658 | 0 | 0.00 / 725.98 | 3 | 4 |
3 | 12 | 2004.80 | 34 | 8.64 | 2948 | 866 | 1.00 / 726.85 | 3 | 3 |
4 | 7 | 2002.44 | 25 | 10.70 | 3183 | 851 | 1.85 / 727.70 | 3 | 3 |
5 | 13 | 1872.04 | 37 | 11.97 | 3023 | 1339 | 3.19 / 729.04 | 3 | 3 |
6 | 13 | 935.08 | 37 | 13.05 | 1714 | 828 | 4.02 / 729.87 | 3 | 8 |
7 | 13 | 80.40 | 5 | 13.84 | 589 | 41 | 4.06 / 729.91 | 3 | 7 |
8 | 13 | 58.76 | 5 | 13.87 | 591 | 41 | 4.10 / 729.95 | 3 | 7 |
9 | 13 | 50.52 | 5 | 13.84 | 580 | 40 | 4.14 / 729.99 | 3 | 7 |
10 | 13 | 45.40 | 5 | 13.81 | 573 | 40 | 4.18 / 730.03 | 3 | 6 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 14 | 13.85 | 672 | 130 | 0.13 / 721.84 | 3 | 3 |
2 | 3 | 1024.92 | 1 | 12.37 | 1906 | 24 | 0.15 / 721.86 | 3 | 3 |
3 | 12 | 2005.68 | 34 | 8.76 | 2995 | 892 | 1.05 / 722.75 | 3 | 3 |
4 | 7 | 2003.28 | 25 | 10.72 | 3208 | 860 | 1.91 / 723.61 | 3 | 3 |
5 | 13 | 1874.08 | 37 | 11.99 | 3046 | 1351 | 3.26 / 724.96 | 3 | 3 |
6 | 13 | 824.04 | 37 | 13.15 | 1564 | 761 | 4.02 / 725.72 | 3 | 9 |
7 | 13 | 66.40 | 5 | 13.85 | 592 | 41 | 4.06 / 725.76 | 3 | 6 |
8 | 13 | 54.36 | 5 | 13.83 | 594 | 41 | 4.10 / 725.81 | 3 | 7 |
9 | 13 | 42.96 | 5 | 13.84 | 588 | 41 | 4.14 / 725.85 | 3 | 7 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 14 | 13.88 | 655 | 127 | 0.13 / 717.77 | 3 | 3 |
2 | 12 | 2003.40 | 34 | 8.68 | 2963 | 874 | 1.00 / 718.65 | 3 | 3 |
3 | 7 | 2000.96 | 25 | 10.60 | 3165 | 839 | 1.84 / 719.49 | 3 | 3 |
4 | 13 | 1868.44 | 37 | 11.95 | 3012 | 1332 | 3.17 / 720.82 | 3 | 3 |
5 | 13 | 835.04 | 37 | 13.13 | 1572 | 764 | 3.94 / 721.58 | 3 | 8 |
6 | 13 | 67.16 | 5 | 13.83 | 591 | 41 | 3.98 / 721.62 | 3 | 7 |
7 | 13 | 53.44 | 5 | 13.83 | 599 | 41 | 4.02 / 721.67 | 3 | 7 |
8 | 13 | 46.36 | 5 | 13.82 | 585 | 40 | 4.06 / 721.71 | 3 | 6 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 15 | 13.85 | 668 | 139 | 0.14 / 713.79 | 3 | 4 |
2 | 3 | 977.72 | -1 | 13.85 | 668 | 0 | 0.00 / 713.79 | 3 | 4 |
3 | 12 | 2002.52 | 34 | 8.90 | 3006 | 910 | 1.05 / 714.69 | 3 | 3 |
4 | 7 | 1999.84 | 25 | 10.75 | 3188 | 857 | 1.91 / 715.55 | 3 | 3 |
5 | 13 | 1736.72 | 37 | 12.20 | 2857 | 1290 | 3.19 / 716.84 | 3 | 4 |
6 | 13 | 828.36 | 37 | 13.15 | 1573 | 765 | 3.96 / 717.61 | 3 | 9 |
7 | 13 | 58.28 | 5 | 13.85 | 586 | 41 | 4.00 / 717.65 | 3 | 6 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 15 | 13.90 | 652 | 136 | 0.14 / 709.75 | 3 | 3 |
2 | 12 | 2004.32 | 34 | 8.78 | 2975 | 888 | 1.02 / 710.64 | 3 | 3 |
3 | 7 | 2001.92 | 25 | 10.63 | 3164 | 841 | 1.86 / 711.48 | 3 | 3 |
4 | 13 | 1871.00 | 37 | 11.94 | 3029 | 1338 | 3.20 / 712.82 | 3 | 3 |
5 | 13 | 812.68 | 37 | 13.15 | 1543 | 751 | 3.95 / 713.57 | 3 | 9 |
6 | 13 | 60.60 | 5 | 13.86 | 573 | 40 | 3.99 / 713.61 | 3 | 6 |
7 | 13 | 40.08 | 5 | 13.87 | 573 | 40 | 4.03 / 713.65 | 3 | 6 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 15 | 13.87 | 661 | 138 | 0.14 / 705.64 | 3 | 3 |
2 | 12 | 2003.44 | 34 | 9.02 | 3000 | 920 | 1.06 / 706.56 | 3 | 3 |
3 | 7 | 2000.68 | 25 | 10.69 | 3182 | 850 | 1.91 / 707.41 | 3 | 3 |
4 | 13 | 1733.04 | 37 | 12.21 | 2849 | 1287 | 3.20 / 708.70 | 3 | 4 |
5 | 13 | 956.72 | 37 | 13.03 | 1729 | 834 | 4.03 / 709.53 | 3 | 8 |
6 | 13 | 55.40 | 5 | 13.85 | 567 | 39 | 4.07 / 709.57 | 3 | 7 |
7 | 13 | 47.20 | 5 | 13.85 | 585 | 41 | 4.11 / 709.61 | 3 | 6 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 15 | 13.87 | 657 | 137 | 0.14 / 701.57 | 3 | 4 |
2 | 12 | 2006.12 | 34 | 8.92 | 2998 | 909 | 1.05 / 702.48 | 3 | 3 |
3 | 7 | 2003.64 | 25 | 10.68 | 3164 | 845 | 1.89 / 703.33 | 3 | 3 |
4 | 13 | 1874.08 | 37 | 11.98 | 3031 | 1344 | 3.23 / 704.67 | 3 | 3 |
5 | 13 | 812.64 | 37 | 13.15 | 1548 | 753 | 3.99 / 705.43 | 3 | 9 |
6 | 13 | 61.28 | 5 | 13.85 | 570 | 39 | 4.03 / 705.47 | 3 | 6 |
7 | 13 | 49.84 | 5 | 13.85 | 573 | 40 | 4.07 / 705.50 | 3 | 6 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 13 | 13.88 | 665 | 120 | 0.12 / 697.46 | 3 | 3 |
2 | 3 | 1047.88 | 1 | 12.84 | 1934 | 25 | 0.14 / 697.48 | 3 | 3 |
3 | 12 | 2002.32 | 34 | 9.21 | 3034 | 950 | 1.09 / 698.43 | 3 | 3 |
4 | 7 | 1999.48 | 25 | 10.76 | 3178 | 855 | 1.95 / 699.29 | 3 | 3 |
5 | 13 | 1735.32 | 37 | 12.29 | 2823 | 1284 | 3.23 / 700.57 | 3 | 4 |
6 | 13 | 809.84 | 37 | 13.17 | 1535 | 748 | 3.98 / 701.32 | 3 | 9 |
7 | 13 | 48.00 | 5 | 13.86 | 574 | 40 | 4.02 / 701.36 | 3 | 7 |
8 | 13 | 44.24 | 5 | 13.86 | 584 | 40 | 4.06 / 701.40 | 3 | 7 |
9 | 13 | 41.44 | 5 | 13.83 | 590 | 41 | 4.10 / 701.44 | 3 | 6 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 15 | 13.86 | 671 | 140 | 0.14 / 693.30 | 3 | 5 |
2 | 3 | 937.60 | -2 | 13.86 | 671 | 0 | 0.00 / 693.30 | 3 | 5 |
3 | 12 | 2004.88 | 34 | 9.16 | 3036 | 946 | 1.09 / 694.25 | 3 | 3 |
4 | 7 | 2002.16 | 25 | 10.85 | 3180 | 863 | 1.95 / 695.11 | 3 | 3 |
5 | 13 | 1871.28 | 37 | 12.04 | 3047 | 1357 | 3.30 / 696.47 | 3 | 4 |
6 | 13 | 803.92 | 37 | 13.18 | 1525 | 744 | 4.05 / 697.21 | 3 | 9 |
7 | 13 | 80.64 | 5 | 13.85 | 617 | 43 | 4.09 / 697.25 | 3 | 7 |
8 | 13 | 59.52 | 5 | 13.85 | 597 | 41 | 4.13 / 697.29 | 3 | 8 |
9 | 13 | 44.88 | 5 | 13.85 | 595 | 41 | 4.17 / 697.34 | 3 | 7 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 26 | 13.87 | 642 | 232 | 0.23 / 689.27 | 3 | 7 |
2 | 3 | 654.28 | -9 | 13.87 | 642 | 0 | 0.00 / 689.27 | 3 | 7 |
3 | 3 | 907.16 | -2 | 13.87 | 642 | 0 | 0.00 / 689.27 | 3 | 7 |
4 | 12 | 2002.76 | 34 | 9.20 | 3003 | 939 | 1.17 / 690.21 | 3 | 3 |
5 | 7 | 2000.28 | 25 | 10.82 | 3170 | 857 | 2.03 / 691.07 | 3 | 3 |
6 | 13 | 1868.00 | 37 | 12.06 | 3028 | 1351 | 3.38 / 692.42 | 3 | 4 |
7 | 13 | 785.12 | 37 | 13.18 | 1520 | 741 | 4.12 / 693.16 | 3 | 10 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 27 | 13.77 | 659 | 245 | 0.25 / 685.18 | 3 | 6 |
2 | 3 | 958.56 | -1 | 13.77 | 659 | 0 | 0.00 / 685.18 | 3 | 6 |
3 | 12 | 2002.32 | 34 | 9.33 | 3020 | 958 | 1.20 / 686.14 | 3 | 3 |
4 | 7 | 1999.40 | 25 | 10.92 | 3183 | 869 | 2.07 / 687.01 | 3 | 3 |
5 | 13 | 1736.68 | 37 | 12.28 | 2869 | 1304 | 3.38 / 688.31 | 3 | 5 |
6 | 13 | 687.80 | 37 | 13.26 | 1400 | 687 | 4.06 / 689.00 | 3 | 11 |
7 | 13 | 50.48 | 5 | 13.86 | 575 | 40 | 4.10 / 689.04 | 3 | 7 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 27 | 13.82 | 639 | 238 | 0.24 / 679.54 | 3 | 5 |
2 | 12 | 2001.00 | 34 | 9.35 | 3036 | 965 | 1.20 / 680.50 | 3 | 3 |
3 | 7 | 1997.92 | 25 | 11.00 | 3180 | 874 | 2.08 / 681.38 | 3 | 3 |
4 | 13 | 1730.48 | 37 | 12.30 | 2847 | 1296 | 3.37 / 682.67 | 3 | 4 |
5 | 13 | 663.20 | 37 | 13.30 | 1340 | 659 | 4.03 / 683.33 | 3 | 10 |
6 | 13 | 59.76 | 5 | 13.87 | 579 | 40 | 4.07 / 683.37 | 3 | 6 |
7 | 13 | 17.28 | 37 | 13.87 | 531 | 273 | 4.35 / 683.65 | 3 | 6 |
8 | 8 | 0.04 | 190 | 13.52 | 503 | 1292 | 5.64 / 684.94 | 3 | 15 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 27 | 13.79 | 647 | 241 | 0.24 / 674.11 | 3 | 5 |
2 | 12 | 2004.44 | 34 | 9.51 | 3030 | 980 | 1.22 / 675.09 | 3 | 3 |
3 | 7 | 2001.68 | 25 | 11.08 | 3165 | 877 | 2.10 / 675.97 | 3 | 3 |
4 | 13 | 1867.08 | 37 | 12.14 | 3012 | 1353 | 3.45 / 677.32 | 3 | 4 |
5 | 13 | 645.92 | 37 | 13.33 | 1307 | 645 | 4.09 / 677.97 | 3 | 11 |
6 | 13 | 58.00 | 5 | 13.87 | 570 | 40 | 4.13 / 678.01 | 3 | 9 |
7 | 8 | 0.20 | 190 | 13.57 | 502 | 1294 | 5.43 / 679.30 | 3 | 10 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 13.76 | 662 | 255 | 0.26 / 668.67 | 3 | 5 |
2 | 3 | 961.20 | -1 | 13.76 | 662 | 0 | 0.00 / 668.67 | 3 | 5 |
3 | 12 | 2002.08 | 34 | 9.54 | 3058 | 992 | 1.25 / 669.66 | 3 | 3 |
4 | 7 | 1999.12 | 25 | 11.10 | 3176 | 881 | 2.13 / 670.54 | 3 | 3 |
5 | 13 | 1730.12 | 37 | 12.31 | 2834 | 1291 | 3.42 / 671.83 | 3 | 5 |
6 | 13 | 652.92 | 37 | 13.30 | 1338 | 658 | 4.08 / 672.49 | 3 | 11 |
7 | 13 | 56.60 | 5 | 13.89 | 567 | 39 | 4.12 / 672.53 | 3 | 7 |
8 | 13 | 44.08 | 5 | 13.87 | 580 | 40 | 4.16 / 672.57 | 3 | 8 |
9 | 8 | 0.28 | 190 | 13.57 | 504 | 1299 | 5.46 / 673.87 | 3 | 15 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 27 | 13.85 | 636 | 238 | 0.24 / 663.21 | 3 | 4 |
2 | 3 | 1027.96 | 1 | 12.38 | 1902 | 24 | 0.26 / 663.23 | 3 | 3 |
3 | 12 | 2002.84 | 34 | 9.71 | 3082 | 1017 | 1.28 / 664.25 | 3 | 3 |
4 | 7 | 1999.68 | 25 | 11.21 | 3182 | 892 | 2.17 / 665.14 | 3 | 3 |
5 | 13 | 1598.64 | 37 | 12.45 | 2660 | 1225 | 3.40 / 666.37 | 3 | 5 |
6 | 13 | 544.28 | 37 | 13.41 | 1196 | 593 | 3.99 / 666.96 | 3 | 10 |
7 | 13 | 50.76 | 5 | 13.87 | 576 | 40 | 4.03 / 667.00 | 3 | 7 |
8 | 13 | 46.16 | 5 | 13.85 | 595 | 41 | 4.07 / 667.04 | 3 | 8 |
9 | 13 | 43.84 | 5 | 13.83 | 586 | 41 | 4.11 / 667.08 | 3 | 7 |
10 | 13 | 41.56 | 5 | 13.83 | 584 | 40 | 4.15 / 667.12 | 3 | 7 |
11 | 8 | 0.20 | 190 | 13.54 | 502 | 1291 | 5.44 / 668.42 | 3 | 8 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 27 | 13.79 | 644 | 240 | 0.24 / 657.83 | 3 | 4 |
2 | 12 | 2001.96 | 34 | 9.82 | 3053 | 1019 | 1.26 / 658.85 | 3 | 3 |
3 | 7 | 1999.04 | 25 | 11.19 | 3177 | 889 | 2.15 / 659.74 | 3 | 3 |
4 | 13 | 1729.76 | 37 | 12.32 | 2836 | 1293 | 3.44 / 661.03 | 3 | 5 |
5 | 13 | 523.76 | 37 | 13.44 | 1151 | 572 | 4.01 / 661.60 | 3 | 11 |
6 | 13 | 45.32 | 5 | 13.88 | 572 | 40 | 4.05 / 661.64 | 3 | 9 |
7 | 13 | 42.28 | 5 | 13.87 | 573 | 40 | 4.09 / 661.68 | 3 | 8 |
8 | 8 | 0.16 | 190 | 13.55 | 501 | 1290 | 5.38 / 662.97 | 3 | 17 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 28 | 13.78 | 649 | 250 | 0.25 / 652.45 | 3 | 5 |
2 | 3 | 946.48 | -1 | 13.78 | 649 | 0 | 0.00 / 652.45 | 3 | 5 |
3 | 12 | 2003.80 | 34 | 9.92 | 3064 | 1033 | 1.28 / 653.48 | 3 | 3 |
4 | 7 | 2000.84 | 25 | 11.26 | 3164 | 891 | 2.17 / 654.37 | 3 | 3 |
5 | 13 | 1597.00 | 37 | 12.45 | 2650 | 1221 | 3.40 / 655.59 | 3 | 5 |
6 | 13 | 537.64 | 37 | 13.41 | 1173 | 582 | 3.98 / 656.18 | 3 | 11 |
7 | 13 | 50.84 | 5 | 13.88 | 576 | 40 | 4.02 / 656.22 | 3 | 8 |
8 | 13 | 45.72 | 5 | 13.87 | 583 | 40 | 4.06 / 656.26 | 3 | 9 |
9 | 13 | 42.48 | 5 | 13.83 | 577 | 40 | 4.10 / 656.30 | 3 | 8 |
10 | 8 | 0.60 | 190 | 13.54 | 503 | 1294 | 5.39 / 657.59 | 3 | 11 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 27 | 13.83 | 646 | 241 | 0.24 / 646.89 | 3 | 3 |
2 | 3 | 1023.04 | 1 | 12.27 | 1892 | 23 | 0.26 / 646.91 | 3 | 3 |
3 | 12 | 2004.20 | 34 | 10.15 | 3071 | 1060 | 1.32 / 647.97 | 3 | 3 |
4 | 7 | 2000.92 | 25 | 11.26 | 3188 | 897 | 2.22 / 648.87 | 3 | 3 |
5 | 13 | 1583.84 | 37 | 12.47 | 2643 | 1219 | 3.44 / 650.09 | 3 | 5 |
6 | 13 | 522.28 | 37 | 13.44 | 1152 | 573 | 4.01 / 650.66 | 3 | 10 |
7 | 13 | 3.96 | 37 | 13.88 | 518 | 266 | 4.28 / 650.93 | 3 | 11 |
8 | 8 | -0.48 | 190 | 13.46 | 497 | 1271 | 5.55 / 652.20 | 3 | 12 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 27 | 13.87 | 625 | 234 | 0.23 / 641.36 | 3 | 3 |
2 | 12 | 2002.28 | 34 | 10.23 | 3054 | 1062 | 1.30 / 642.42 | 3 | 3 |
3 | 7 | 1999.00 | 25 | 11.27 | 3162 | 891 | 2.19 / 643.31 | 3 | 3 |
4 | 13 | 1586.08 | 37 | 12.48 | 2640 | 1219 | 3.41 / 644.53 | 3 | 5 |
5 | 13 | 517.40 | 37 | 13.44 | 1150 | 572 | 3.98 / 645.10 | 3 | 11 |
6 | 13 | 17.16 | 37 | 13.87 | 537 | 276 | 4.25 / 645.38 | 3 | 7 |
7 | 8 | 0.20 | 190 | 13.45 | 496 | 1268 | 5.52 / 646.65 | 3 | 13 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.96 | 26 | 13.84 | 644 | 232 | 0.23 / 635.83 | 3 | 4 |
2 | 3 | 1032.56 | 1 | 12.64 | 1892 | 24 | 0.26 / 635.85 | 3 | 3 |
3 | 12 | 2002.08 | 34 | 10.25 | 3067 | 1069 | 1.32 / 636.92 | 3 | 3 |
4 | 7 | 1998.60 | 25 | 11.28 | 3184 | 898 | 2.22 / 637.82 | 3 | 3 |
5 | 13 | 1583.36 | 37 | 12.49 | 2639 | 1220 | 3.44 / 639.04 | 3 | 6 |
6 | 13 | 518.68 | 37 | 13.45 | 1144 | 569 | 4.01 / 639.61 | 3 | 12 |
7 | 13 | 1.68 | 37 | 13.91 | 518 | 267 | 4.28 / 639.88 | 3 | 9 |
8 | 8 | 0.00 | 190 | 13.49 | 488 | 1251 | 5.53 / 641.13 | 3 | 17 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 13 | 13.91 | 624 | 113 | 0.11 / 629.83 | 3 | 3 |
2 | 10 | 1073.12 | 6 | 13.43 | 1937 | 156 | 0.27 / 629.99 | 3 | 3 |
3 | 10 | 1111.24 | 4 | 13.57 | 1991 | 108 | 0.38 / 630.10 | 3 | 3 |
4 | 3 | 1111.20 | 3 | 13.16 | 2065 | 82 | 0.46 / 630.18 | 3 | 4 |
5 | 3 | 1026.20 | 1 | 12.52 | 1905 | 24 | 0.48 / 630.20 | 3 | 3 |
6 | 12 | 2004.80 | 30 | 10.21 | 3050 | 934 | 1.42 / 631.14 | 3 | 3 |
7 | 7 | 2001.96 | 25 | 11.33 | 3192 | 904 | 2.32 / 632.04 | 3 | 3 |
8 | 13 | 1737.36 | 37 | 12.37 | 2843 | 1301 | 3.62 / 633.34 | 3 | 5 |
9 | 13 | 793.84 | 37 | 13.24 | 1498 | 734 | 4.36 / 634.07 | 3 | 10 |
10 | 13 | 17.48 | 37 | 13.90 | 524 | 269 | 4.63 / 634.34 | 3 | 6 |
11 | 8 | -0.24 | 190 | 13.55 | 487 | 1254 | 5.88 / 635.60 | 3 | 11 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 15 | 13.89 | 642 | 134 | 0.13 / 624.19 | 3 | 5 |
2 | 3 | 927.56 | -2 | 13.89 | 642 | 0 | 0.00 / 624.19 | 3 | 5 |
3 | 12 | 2003.96 | 30 | 10.30 | 3061 | 946 | 1.08 / 625.13 | 3 | 3 |
4 | 7 | 2001.20 | 25 | 11.35 | 3165 | 898 | 1.98 / 626.03 | 3 | 3 |
5 | 13 | 1728.84 | 37 | 12.38 | 2799 | 1282 | 3.26 / 627.31 | 3 | 4 |
6 | 13 | 653.40 | 37 | 13.33 | 1330 | 656 | 3.92 / 627.97 | 3 | 11 |
7 | 13 | 18.00 | 37 | 13.91 | 527 | 271 | 4.19 / 628.24 | 3 | 7 |
8 | 13 | 6.32 | 37 | 13.78 | 505 | 257 | 4.44 / 628.50 | 3 | 6 |
9 | 8 | -0.24 | 190 | 13.44 | 478 | 1221 | 5.67 / 629.72 | 3 | 14 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 14 | 13.90 | 665 | 129 | 0.13 / 620.19 | 3 | 4 |
2 | 3 | 1030.48 | 1 | 12.70 | 1893 | 24 | 0.15 / 620.21 | 3 | 3 |
3 | 12 | 2001.00 | 30 | 10.47 | 3068 | 964 | 1.12 / 621.18 | 3 | 3 |
4 | 7 | 1998.32 | 25 | 11.31 | 3226 | 912 | 2.03 / 622.09 | 3 | 3 |
5 | 13 | 1731.64 | 37 | 12.38 | 2846 | 1304 | 3.33 / 623.39 | 3 | 4 |
6 | 13 | 638.68 | 37 | 13.33 | 1337 | 659 | 3.99 / 624.05 | 3 | 11 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 15 | 13.87 | 632 | 131 | 0.13 / 616.19 | 3 | 5 |
2 | 3 | 963.40 | -1 | 13.87 | 632 | 0 | 0.00 / 616.19 | 3 | 5 |
3 | 12 | 2004.44 | 30 | 10.38 | 3076 | 958 | 1.09 / 617.15 | 3 | 3 |
4 | 7 | 2001.56 | 25 | 11.33 | 3189 | 903 | 1.99 / 618.06 | 3 | 3 |
5 | 13 | 1734.48 | 37 | 12.38 | 2841 | 1301 | 3.29 / 619.36 | 3 | 4 |
6 | 13 | 671.32 | 37 | 13.33 | 1351 | 666 | 3.96 / 620.02 | 3 | 10 |
7 | 13 | 40.84 | 5 | 13.89 | 550 | 38 | 4.00 / 620.06 | 3 | 8 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 15 | 13.90 | 645 | 134 | 0.13 / 612.26 | 3 | 4 |
2 | 12 | 2002.92 | 30 | 10.50 | 3054 | 962 | 1.10 / 613.22 | 3 | 3 |
3 | 7 | 1999.92 | 25 | 11.33 | 3188 | 903 | 2.00 / 614.12 | 3 | 3 |
4 | 13 | 1725.72 | 37 | 12.39 | 2829 | 1297 | 3.30 / 615.42 | 3 | 4 |
5 | 13 | 635.52 | 37 | 13.36 | 1304 | 645 | 3.94 / 616.06 | 3 | 11 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 13 | 13.92 | 639 | 116 | 0.12 / 608.26 | 3 | 4 |
2 | 3 | 1034.84 | 1 | 12.75 | 1924 | 25 | 0.14 / 608.29 | 3 | 3 |
3 | 12 | 2003.00 | 30 | 10.55 | 3076 | 974 | 1.11 / 609.26 | 3 | 3 |
4 | 7 | 1999.96 | 25 | 11.36 | 3186 | 905 | 2.02 / 610.17 | 3 | 3 |
5 | 13 | 1725.16 | 37 | 12.40 | 2831 | 1299 | 3.32 / 611.46 | 3 | 5 |
6 | 13 | 640.64 | 37 | 13.34 | 1332 | 657 | 3.97 / 612.12 | 3 | 11 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 14 | 13.89 | 649 | 126 | 0.13 / 604.37 | 3 | 5 |
2 | 3 | 968.68 | -1 | 13.89 | 649 | 0 | 0.00 / 604.37 | 3 | 5 |
3 | 12 | 2004.68 | 30 | 10.50 | 3074 | 968 | 1.09 / 605.34 | 3 | 3 |
4 | 7 | 2001.84 | 25 | 11.37 | 3200 | 910 | 2.00 / 606.25 | 3 | 3 |
5 | 13 | 1598.72 | 37 | 12.52 | 2656 | 1230 | 3.23 / 607.48 | 3 | 5 |
6 | 13 | 541.40 | 37 | 13.45 | 1191 | 593 | 3.83 / 608.07 | 3 | 11 |
7 | 13 | 44.08 | 5 | 13.91 | 564 | 39 | 3.87 / 608.11 | 3 | 7 |
8 | 13 | 40.80 | 5 | 13.90 | 572 | 40 | 3.91 / 608.15 | 3 | 8 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 15 | 13.89 | 663 | 138 | 0.14 / 600.43 | 3 | 5 |
2 | 3 | 956.12 | -1 | 13.89 | 663 | 0 | 0.00 / 600.43 | 3 | 5 |
3 | 12 | 2001.28 | 30 | 10.56 | 3064 | 971 | 1.11 / 601.40 | 3 | 3 |
4 | 7 | 1998.16 | 25 | 11.37 | 3172 | 902 | 2.01 / 602.30 | 3 | 3 |
5 | 13 | 1722.92 | 37 | 12.42 | 2800 | 1287 | 3.30 / 603.59 | 3 | 4 |
6 | 13 | 647.20 | 37 | 13.37 | 1320 | 653 | 3.95 / 604.24 | 3 | 11 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 14 | 13.91 | 651 | 127 | 0.13 / 596.39 | 3 | 4 |
2 | 3 | 1044.92 | 1 | 12.92 | 1941 | 25 | 0.15 / 596.42 | 3 | 3 |
3 | 3 | 1020.72 | 1 | 12.45 | 1921 | 24 | 0.18 / 596.44 | 3 | 3 |
4 | 12 | 2004.28 | 30 | 10.60 | 3082 | 980 | 1.16 / 597.42 | 3 | 3 |
5 | 7 | 2001.36 | 25 | 11.38 | 3184 | 906 | 2.06 / 598.33 | 3 | 3 |
6 | 13 | 1730.16 | 37 | 12.42 | 2855 | 1312 | 3.37 / 599.64 | 3 | 5 |
7 | 13 | 646.04 | 37 | 13.36 | 1313 | 649 | 4.02 / 600.29 | 3 | 10 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 15 | 13.92 | 643 | 134 | 0.13 / 592.47 | 3 | 5 |
2 | 3 | 951.92 | -1 | 13.92 | 643 | 0 | 0.00 / 592.47 | 3 | 5 |
3 | 12 | 2001.40 | 30 | 10.57 | 3068 | 973 | 1.11 / 593.44 | 3 | 3 |
4 | 7 | 1998.32 | 25 | 11.39 | 3189 | 908 | 2.02 / 594.35 | 3 | 3 |
5 | 13 | 1595.44 | 37 | 12.55 | 2632 | 1222 | 3.24 / 595.57 | 3 | 5 |
6 | 13 | 528.12 | 37 | 13.47 | 1159 | 578 | 3.81 / 596.15 | 3 | 11 |
7 | 13 | 52.88 | 5 | 13.92 | 568 | 40 | 3.85 / 596.19 | 3 | 7 |
8 | 13 | 47.12 | 5 | 13.89 | 577 | 40 | 3.89 / 596.23 | 3 | 8 |
9 | 13 | 43.36 | 5 | 13.90 | 575 | 40 | 3.93 / 596.27 | 3 | 8 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 14 | 13.93 | 658 | 128 | 0.13 / 588.32 | 3 | 4 |
2 | 3 | 1034.84 | 1 | 12.88 | 1914 | 25 | 0.15 / 588.35 | 3 | 3 |
3 | 12 | 2006.04 | 30 | 10.67 | 3097 | 991 | 1.14 / 589.34 | 3 | 3 |
4 | 7 | 2003.20 | 25 | 11.41 | 3194 | 911 | 2.06 / 590.25 | 3 | 3 |
5 | 13 | 1868.84 | 37 | 12.27 | 3018 | 1370 | 3.43 / 591.62 | 3 | 4 |
6 | 13 | 746.60 | 37 | 13.28 | 1450 | 712 | 4.14 / 592.33 | 3 | 10 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 16 | 13.93 | 630 | 140 | 0.14 / 584.48 | 3 | 5 |
2 | 3 | 946.08 | -1 | 13.93 | 630 | 0 | 0.00 / 584.48 | 3 | 5 |
3 | 3 | 980.00 | -1 | 13.93 | 630 | 0 | 0.00 / 584.48 | 3 | 5 |
4 | 12 | 2001.72 | 30 | 10.64 | 3078 | 982 | 1.12 / 585.46 | 3 | 3 |
5 | 7 | 1998.40 | 25 | 11.41 | 3178 | 907 | 2.03 / 586.37 | 3 | 3 |
6 | 13 | 1592.00 | 37 | 12.54 | 2655 | 1232 | 3.26 / 587.60 | 3 | 5 |
7 | 13 | 544.40 | 37 | 13.46 | 1198 | 597 | 3.86 / 588.20 | 3 | 11 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 13 | 13.93 | 650 | 118 | 0.12 / 580.58 | 3 | 4 |
2 | 3 | 1070.04 | 2 | 13.18 | 1971 | 52 | 0.17 / 580.63 | 3 | 3 |
3 | 12 | 2002.24 | 30 | 10.76 | 3086 | 996 | 1.17 / 581.63 | 3 | 3 |
4 | 7 | 1999.16 | 25 | 11.42 | 3182 | 908 | 2.07 / 582.54 | 3 | 3 |
5 | 13 | 1598.08 | 37 | 12.55 | 2638 | 1225 | 3.30 / 583.76 | 3 | 5 |
6 | 13 | 529.52 | 37 | 13.48 | 1157 | 577 | 3.88 / 584.34 | 3 | 11 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 26 | 13.88 | 629 | 227 | 0.23 / 576.61 | 3 | 9 |
2 | 3 | 618.20 | -10 | 13.88 | 629 | 0 | 0.00 / 576.61 | 3 | 9 |
3 | 3 | 881.68 | -3 | 13.88 | 629 | 0 | 0.00 / 576.61 | 3 | 9 |
4 | 12 | 2001.88 | 30 | 10.73 | 3078 | 991 | 1.22 / 577.61 | 3 | 3 |
5 | 7 | 1998.56 | 25 | 11.38 | 3185 | 906 | 2.12 / 578.51 | 3 | 3 |
6 | 13 | 1725.32 | 37 | 12.43 | 2844 | 1308 | 3.43 / 579.82 | 3 | 5 |
7 | 13 | 511.40 | 37 | 13.49 | 1128 | 563 | 3.99 / 580.38 | 3 | 11 |
8 | 13 | 58.48 | 5 | 13.95 | 564 | 39 | 4.03 / 580.42 | 3 | 8 |
9 | 13 | 49.00 | 5 | 13.90 | 570 | 40 | 4.07 / 580.46 | 3 | 8 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 27 | 13.84 | 644 | 241 | 0.24 / 572.91 | 3 | 7 |
2 | 3 | 979.96 | -1 | 13.84 | 644 | 0 | 0.00 / 572.91 | 3 | 7 |
3 | 12 | 2001.76 | 30 | 10.68 | 3076 | 986 | 1.23 / 573.89 | 3 | 3 |
4 | 7 | 1998.52 | 25 | 11.40 | 3224 | 919 | 2.15 / 574.81 | 3 | 3 |
5 | 13 | 1590.32 | 37 | 12.56 | 2639 | 1226 | 3.37 / 576.04 | 3 | 6 |
6 | 13 | 396.56 | 9 | 13.77 | 994 | 123 | 3.49 / 576.16 | 3 | 11 |
7 | 13 | 267.80 | 5 | 13.86 | 840 | 58 | 3.55 / 576.22 | 3 | 11 |
8 | 13 | 101.48 | 5 | 13.92 | 632 | 44 | 3.60 / 576.26 | 3 | 9 |
9 | 13 | 74.84 | 5 | 13.91 | 607 | 42 | 3.64 / 576.31 | 3 | 9 |
10 | 13 | 61.32 | 5 | 13.90 | 589 | 41 | 3.68 / 576.35 | 3 | 8 |
11 | 13 | 52.08 | 5 | 13.88 | 586 | 41 | 3.72 / 576.39 | 3 | 9 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 26 | 13.83 | 660 | 237 | 0.24 / 567.58 | 3 | 7 |
2 | 12 | 2001.92 | 30 | 10.81 | 3072 | 996 | 1.23 / 568.58 | 3 | 3 |
3 | 7 | 1998.80 | 25 | 11.43 | 3163 | 904 | 2.14 / 569.48 | 3 | 3 |
4 | 13 | 1586.60 | 37 | 12.57 | 2646 | 1231 | 3.37 / 570.71 | 3 | 6 |
5 | 13 | 639.40 | 37 | 13.39 | 1307 | 648 | 4.02 / 571.36 | 3 | 12 |
6 | 8 | 0.28 | 190 | 13.58 | 507 | 1308 | 5.32 / 572.67 | 3 | 12 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 26 | 13.86 | 633 | 228 | 0.23 / 562.23 | 3 | 7 |
2 | 12 | 2001.20 | 30 | 10.72 | 3091 | 994 | 1.22 / 563.22 | 3 | 3 |
3 | 7 | 1997.88 | 24 | 11.54 | 3146 | 871 | 2.09 / 564.09 | 3 | 3 |
4 | 13 | 1724.80 | 37 | 12.45 | 2828 | 1303 | 3.40 / 565.40 | 3 | 5 |
5 | 13 | 646.68 | 37 | 13.39 | 1322 | 655 | 4.05 / 566.05 | 3 | 12 |
6 | 8 | 0.36 | 190 | 13.59 | 500 | 1291 | 5.34 / 567.34 | 3 | 10 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 26 | 13.82 | 640 | 230 | 0.23 / 557.05 | 3 | 8 |
2 | 12 | 2002.20 | 30 | 10.78 | 3065 | 991 | 1.22 / 558.04 | 3 | 3 |
3 | 7 | 1999.28 | 25 | 11.45 | 3155 | 903 | 2.12 / 558.94 | 3 | 3 |
4 | 13 | 1465.32 | 37 | 12.68 | 2469 | 1158 | 3.28 / 560.10 | 3 | 7 |
5 | 13 | 569.68 | 37 | 13.45 | 1214 | 604 | 3.89 / 560.71 | 3 | 12 |
6 | 8 | -0.16 | 190 | 13.58 | 502 | 1295 | 5.18 / 562.00 | 3 | 9 |
Average= | 4.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 26 | 13.84 | 645 | 232 | 0.23 / 551.49 | 3 | 8 |
2 | 12 | 2002.20 | 30 | 10.82 | 3066 | 995 | 1.23 / 552.48 | 3 | 3 |
3 | 7 | 1998.96 | 25 | 11.46 | 3164 | 906 | 2.13 / 553.39 | 3 | 3 |
4 | 13 | 1732.16 | 37 | 12.44 | 2848 | 1311 | 3.44 / 554.70 | 3 | 5 |
5 | 13 | 516.64 | 37 | 13.49 | 1145 | 572 | 4.02 / 555.27 | 3 | 12 |
6 | 13 | 18.36 | 37 | 13.91 | 537 | 276 | 4.29 / 555.55 | 3 | 6 |
7 | 8 | -0.20 | 190 | 13.53 | 494 | 1270 | 5.56 / 556.82 | 3 | 13 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 28 | 13.81 | 622 | 241 | 0.24 / 546.08 | 3 | 6 |
2 | 3 | 915.64 | -2 | 13.81 | 622 | 0 | 0.00 / 546.08 | 3 | 6 |
3 | 12 | 2003.04 | 30 | 10.82 | 3061 | 994 | 1.23 / 547.07 | 3 | 3 |
4 | 7 | 2000.40 | 25 | 11.44 | 3169 | 906 | 2.14 / 547.98 | 3 | 3 |
5 | 13 | 1869.68 | 37 | 12.30 | 3017 | 1373 | 3.51 / 549.35 | 3 | 4 |
6 | 13 | 515.68 | 37 | 13.48 | 1160 | 579 | 4.09 / 549.93 | 3 | 12 |
7 | 13 | 50.80 | 5 | 13.94 | 575 | 40 | 4.13 / 549.97 | 3 | 8 |
8 | 8 | 1.04 | 190 | 13.59 | 498 | 1286 | 5.42 / 551.26 | 3 | 13 |
Average= | 4.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 28 | 13.87 | 632 | 245 | 0.25 / 540.58 | 3 | 5 |
2 | 12 | 2001.28 | 30 | 10.90 | 3066 | 1003 | 1.25 / 541.58 | 3 | 3 |
3 | 7 | 1997.84 | 25 | 11.47 | 3154 | 904 | 2.15 / 542.49 | 3 | 3 |
4 | 13 | 1582.04 | 37 | 12.59 | 2630 | 1225 | 3.38 / 543.71 | 3 | 6 |
5 | 13 | 534.20 | 37 | 13.49 | 1159 | 578 | 3.96 / 544.29 | 3 | 12 |
6 | 13 | 60.92 | 5 | 13.94 | 567 | 40 | 4.00 / 544.33 | 3 | 8 |
7 | 13 | 6.48 | 37 | 13.93 | 517 | 266 | 4.26 / 544.60 | 3 | 6 |
8 | 8 | 0.16 | 190 | 13.49 | 484 | 1241 | 5.50 / 545.84 | 3 | 19 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 27 | 13.89 | 616 | 231 | 0.23 / 535.25 | 3 | 5 |
2 | 3 | 1028.52 | 1 | 12.53 | 1887 | 24 | 0.25 / 535.27 | 3 | 3 |
3 | 12 | 2001.80 | 30 | 10.89 | 3066 | 1002 | 1.26 / 536.27 | 3 | 3 |
4 | 7 | 1998.56 | 25 | 11.44 | 3165 | 905 | 2.16 / 537.18 | 3 | 3 |
5 | 13 | 1588.16 | 37 | 12.59 | 2627 | 1224 | 3.39 / 538.40 | 3 | 6 |
6 | 13 | 529.12 | 37 | 13.48 | 1172 | 585 | 3.97 / 538.98 | 3 | 13 |
7 | 13 | 62.60 | 5 | 13.95 | 577 | 40 | 4.01 / 539.02 | 3 | 9 |
8 | 13 | 52.48 | 5 | 13.95 | 575 | 40 | 4.05 / 539.06 | 3 | 8 |
9 | 8 | 0.00 | 190 | 13.60 | 492 | 1271 | 5.32 / 540.34 | 3 | 12 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 28 | 13.85 | 620 | 240 | 0.24 / 530.05 | 3 | 6 |
2 | 3 | 917.08 | -2 | 13.85 | 620 | 0 | 0.00 / 530.05 | 3 | 6 |
3 | 12 | 2003.52 | 30 | 10.83 | 3073 | 998 | 1.24 / 531.05 | 3 | 3 |
4 | 7 | 2000.16 | 25 | 11.46 | 3169 | 908 | 2.15 / 531.95 | 3 | 3 |
5 | 13 | 1584.92 | 37 | 12.59 | 2625 | 1223 | 3.37 / 533.18 | 3 | 6 |
6 | 13 | 525.64 | 37 | 13.51 | 1142 | 571 | 3.94 / 533.75 | 3 | 12 |
7 | 8 | 0.20 | 190 | 13.63 | 489 | 1266 | 5.21 / 535.01 | 3 | 12 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 29 | 13.85 | 619 | 249 | 0.25 / 524.74 | 3 | 5 |
2 | 3 | 967.16 | -1 | 13.85 | 619 | 0 | 0.00 / 524.74 | 3 | 5 |
3 | 12 | 2001.88 | 30 | 10.88 | 3088 | 1008 | 1.26 / 525.75 | 3 | 3 |
4 | 7 | 1998.88 | 25 | 11.45 | 3157 | 904 | 2.16 / 526.65 | 3 | 3 |
5 | 13 | 1729.32 | 34 | 12.56 | 2827 | 1207 | 3.37 / 527.86 | 3 | 5 |
6 | 13 | 632.32 | 34 | 13.45 | 1303 | 596 | 3.96 / 528.46 | 3 | 12 |
7 | 13 | 62.36 | 5 | 13.94 | 578 | 40 | 4.00 / 528.50 | 3 | 8 |
8 | 13 | 44.80 | 5 | 13.94 | 574 | 40 | 4.04 / 528.54 | 3 | 7 |
9 | 8 | 0.20 | 190 | 13.61 | 491 | 1270 | 5.31 / 529.81 | 3 | 10 |
Average= | 4.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 29 | 13.86 | 612 | 246 | 0.25 / 519.55 | 3 | 4 |
2 | 12 | 1999.80 | 30 | 10.83 | 3073 | 998 | 1.24 / 520.55 | 3 | 3 |
3 | 7 | 1996.28 | 25 | 11.45 | 3144 | 900 | 2.14 / 521.45 | 3 | 3 |
4 | 13 | 1570.24 | 34 | 12.71 | 2609 | 1127 | 3.27 / 522.57 | 3 | 7 |
5 | 13 | 528.96 | 34 | 13.54 | 1148 | 528 | 3.80 / 523.10 | 3 | 12 |
6 | 13 | 64.68 | 5 | 13.97 | 587 | 41 | 3.84 / 523.14 | 3 | 8 |
7 | 13 | 52.52 | 5 | 13.93 | 581 | 40 | 3.88 / 523.18 | 3 | 9 |
8 | 13 | 46.64 | 5 | 13.91 | 572 | 40 | 3.92 / 523.22 | 3 | 8 |
9 | 8 | 0.08 | 190 | 13.59 | 492 | 1270 | 5.19 / 524.49 | 3 | 12 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 29 | 13.90 | 604 | 243 | 0.24 / 514.44 | 3 | 4 |
2 | 3 | 1021.52 | 1 | 11.36 | 1864 | 21 | 0.26 / 514.46 | 3 | 3 |
3 | 12 | 2002.92 | 30 | 10.87 | 3090 | 1008 | 1.27 / 515.47 | 3 | 3 |
4 | 7 | 1999.68 | 25 | 11.47 | 3151 | 904 | 2.18 / 516.37 | 3 | 3 |
5 | 13 | 1549.44 | 34 | 12.72 | 2578 | 1115 | 3.29 / 517.48 | 3 | 7 |
6 | 13 | 551.64 | 34 | 13.51 | 1192 | 548 | 3.84 / 518.03 | 3 | 12 |
7 | 8 | 0.24 | 190 | 13.64 | 490 | 1270 | 5.11 / 519.30 | 3 | 13 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 30 | 13.83 | 624 | 259 | 0.26 / 509.32 | 3 | 4 |
2 | 3 | 959.84 | -1 | 13.83 | 624 | 0 | 0.00 / 509.32 | 3 | 4 |
3 | 12 | 2001.84 | 30 | 10.93 | 3085 | 1012 | 1.27 / 510.33 | 3 | 3 |
4 | 7 | 1998.76 | 25 | 11.47 | 3141 | 901 | 2.17 / 511.23 | 3 | 3 |
5 | 13 | 1555.36 | 34 | 12.72 | 2577 | 1115 | 3.29 / 512.35 | 3 | 6 |
6 | 13 | 551.32 | 34 | 13.51 | 1181 | 542 | 3.83 / 512.89 | 3 | 12 |
7 | 13 | 79.20 | 5 | 13.95 | 606 | 42 | 3.87 / 512.93 | 3 | 9 |
8 | 8 | -0.12 | 190 | 13.63 | 488 | 1264 | 5.13 / 514.19 | 3 | 12 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 29 | 13.88 | 617 | 248 | 0.25 / 504.24 | 3 | 3 |
2 | 12 | 2001.24 | 30 | 10.88 | 3095 | 1010 | 1.26 / 505.25 | 3 | 3 |
3 | 7 | 1997.96 | 25 | 11.50 | 3156 | 907 | 2.17 / 506.15 | 3 | 3 |
4 | 13 | 1541.84 | 34 | 12.75 | 2555 | 1108 | 3.27 / 507.26 | 3 | 6 |
5 | 13 | 364.40 | 8 | 13.82 | 940 | 104 | 3.38 / 507.36 | 3 | 10 |
6 | 13 | 215.32 | 5 | 13.90 | 755 | 52 | 3.43 / 507.42 | 3 | 10 |
7 | 13 | 127.68 | 5 | 13.94 | 651 | 45 | 3.48 / 507.46 | 3 | 9 |
8 | 13 | 86.28 | 5 | 13.93 | 602 | 42 | 3.52 / 507.50 | 3 | 9 |
9 | 13 | 64.80 | 5 | 13.93 | 581 | 40 | 3.56 / 507.55 | 3 | 8 |
10 | 13 | 53.24 | 5 | 13.94 | 567 | 40 | 3.60 / 507.58 | 3 | 7 |
11 | 13 | 5.60 | 34 | 13.94 | 509 | 241 | 3.84 / 507.83 | 3 | 5 |
12 | 8 | 0.40 | 190 | 13.50 | 481 | 1234 | 5.07 / 509.06 | 3 | 12 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 28 | 13.88 | 613 | 238 | 0.24 / 499.06 | 3 | 4 |
2 | 3 | 1039.60 | 1 | 13.10 | 1930 | 25 | 0.26 / 499.09 | 3 | 3 |
3 | 12 | 2002.44 | 30 | 10.96 | 3084 | 1014 | 1.28 / 500.10 | 3 | 3 |
4 | 7 | 1999.28 | 25 | 11.50 | 3147 | 905 | 2.18 / 501.01 | 3 | 3 |
5 | 13 | 1564.48 | 35 | 12.67 | 2590 | 1149 | 3.33 / 502.15 | 3 | 6 |
6 | 13 | 551.28 | 35 | 13.49 | 1182 | 558 | 3.89 / 502.71 | 3 | 12 |
7 | 8 | 0.16 | 190 | 13.62 | 493 | 1276 | 5.16 / 503.99 | 3 | 12 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 29 | 13.93 | 593 | 240 | 0.24 / 494.19 | 3 | 4 |
2 | 3 | 977.88 | -1 | 13.93 | 593 | 0 | 0.00 / 494.19 | 3 | 4 |
3 | 3 | 1018.92 | 1 | 11.32 | 1866 | 21 | 0.26 / 494.21 | 3 | 3 |
4 | 12 | 2002.48 | 30 | 10.98 | 3088 | 1017 | 1.28 / 495.23 | 3 | 3 |
5 | 7 | 1999.48 | 25 | 11.50 | 3155 | 907 | 2.18 / 496.13 | 3 | 3 |
6 | 13 | 1553.56 | 35 | 12.68 | 2559 | 1136 | 3.32 / 497.27 | 3 | 7 |
7 | 13 | 348.08 | 7 | 13.82 | 920 | 89 | 3.41 / 497.36 | 3 | 11 |
8 | 13 | 200.72 | 5 | 13.93 | 738 | 51 | 3.46 / 497.41 | 3 | 10 |
9 | 13 | 127.12 | 5 | 13.94 | 641 | 45 | 3.51 / 497.45 | 3 | 10 |
10 | 13 | 89.44 | 5 | 13.95 | 600 | 42 | 3.55 / 497.49 | 3 | 9 |
11 | 13 | 64.72 | 5 | 13.93 | 586 | 41 | 3.59 / 497.54 | 3 | 9 |
12 | 13 | 52.48 | 5 | 13.91 | 572 | 40 | 3.63 / 497.58 | 3 | 8 |
13 | 8 | -0.24 | 190 | 13.62 | 482 | 1247 | 4.88 / 498.82 | 3 | 10 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 29 | 13.85 | 608 | 244 | 0.24 / 489.09 | 3 | 4 |
2 | 12 | 2001.72 | 30 | 10.97 | 3084 | 1015 | 1.26 / 490.11 | 3 | 3 |
3 | 7 | 1998.52 | 25 | 11.47 | 3144 | 902 | 2.16 / 491.01 | 3 | 3 |
4 | 13 | 1556.92 | 35 | 12.65 | 2596 | 1149 | 3.31 / 492.16 | 3 | 7 |
5 | 13 | 355.44 | 7 | 13.82 | 946 | 92 | 3.40 / 492.25 | 3 | 12 |
6 | 13 | 200.08 | 5 | 13.93 | 735 | 51 | 3.45 / 492.30 | 3 | 11 |
7 | 13 | 130.52 | 5 | 13.95 | 659 | 46 | 3.50 / 492.35 | 3 | 10 |
8 | 13 | 86.08 | 5 | 13.94 | 607 | 42 | 3.54 / 492.39 | 3 | 10 |
9 | 13 | 44.80 | 5 | 13.95 | 554 | 39 | 3.58 / 492.43 | 3 | 8 |
10 | 13 | 41.92 | 5 | 13.92 | 563 | 39 | 3.62 / 492.47 | 3 | 8 |
11 | 13 | 17.28 | 35 | 13.90 | 519 | 252 | 3.87 / 492.72 | 3 | 8 |
12 | 8 | 0.12 | 190 | 13.47 | 480 | 1228 | 5.10 / 493.95 | 3 | 13 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 29 | 13.91 | 594 | 240 | 0.24 / 484.08 | 3 | 3 |
2 | 12 | 2003.96 | 30 | 10.91 | 3086 | 1010 | 1.25 / 485.09 | 3 | 3 |
3 | 7 | 2001.04 | 25 | 11.47 | 3169 | 909 | 2.16 / 486.00 | 3 | 3 |
4 | 13 | 1345.40 | 35 | 12.81 | 2308 | 1035 | 3.19 / 487.04 | 3 | 8 |
5 | 13 | 394.92 | 8 | 13.81 | 993 | 110 | 3.30 / 487.15 | 3 | 11 |
6 | 13 | 217.44 | 5 | 13.90 | 764 | 53 | 3.36 / 487.20 | 3 | 10 |
7 | 13 | 127.92 | 5 | 13.92 | 668 | 46 | 3.40 / 487.25 | 3 | 9 |
8 | 13 | 83.44 | 5 | 13.94 | 611 | 43 | 3.45 / 487.29 | 3 | 9 |
9 | 13 | 48.68 | 5 | 13.97 | 560 | 39 | 3.48 / 487.33 | 3 | 7 |
10 | 13 | 44.32 | 5 | 13.91 | 574 | 40 | 3.52 / 487.37 | 3 | 8 |
11 | 13 | 17.64 | 35 | 13.90 | 530 | 258 | 3.78 / 487.63 | 3 | 7 |
12 | 8 | 0.40 | 190 | 13.45 | 478 | 1222 | 5.00 / 488.85 | 3 | 12 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 29 | 13.89 | 601 | 242 | 0.24 / 479.16 | 3 | 4 |
2 | 12 | 2000.84 | 30 | 10.96 | 3071 | 1010 | 1.25 / 480.17 | 3 | 3 |
3 | 7 | 1997.32 | 25 | 11.48 | 3133 | 899 | 2.15 / 481.07 | 3 | 3 |
4 | 13 | 1335.56 | 35 | 12.85 | 2250 | 1012 | 3.16 / 482.08 | 3 | 7 |
5 | 13 | 391.96 | 8 | 13.81 | 989 | 109 | 3.27 / 482.19 | 3 | 11 |
6 | 13 | 204.44 | 5 | 13.94 | 742 | 52 | 3.32 / 482.24 | 3 | 10 |
7 | 13 | 122.44 | 5 | 13.94 | 651 | 45 | 3.37 / 482.28 | 3 | 9 |
8 | 13 | 83.80 | 5 | 13.95 | 611 | 43 | 3.41 / 482.33 | 3 | 9 |
9 | 13 | 62.68 | 5 | 13.94 | 578 | 40 | 3.45 / 482.37 | 3 | 7 |
10 | 13 | 17.52 | 35 | 13.93 | 514 | 251 | 3.70 / 482.62 | 3 | 7 |
11 | 8 | -0.16 | 190 | 13.48 | 479 | 1227 | 4.93 / 483.84 | 3 | 13 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 29 | 13.94 | 587 | 237 | 0.24 / 473.83 | 3 | 4 |
2 | 3 | 974.76 | -1 | 13.94 | 587 | 0 | 0.00 / 473.83 | 3 | 4 |
3 | 12 | 2002.36 | 30 | 10.96 | 3081 | 1013 | 1.25 / 474.84 | 3 | 3 |
4 | 7 | 1999.28 | 25 | 11.50 | 3162 | 909 | 2.16 / 475.75 | 3 | 3 |
5 | 13 | 1545.04 | 35 | 12.67 | 2575 | 1142 | 3.30 / 476.89 | 3 | 6 |
6 | 13 | 528.36 | 35 | 13.52 | 1145 | 542 | 3.84 / 477.43 | 3 | 12 |
7 | 13 | 16.64 | 35 | 13.95 | 513 | 250 | 4.09 / 477.68 | 3 | 7 |
8 | 8 | 0.24 | 190 | 13.48 | 481 | 1232 | 5.33 / 478.91 | 3 | 14 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 29 | 13.92 | 599 | 242 | 0.24 / 468.62 | 3 | 4 |
2 | 12 | 2000.80 | 30 | 10.94 | 3072 | 1008 | 1.25 / 469.63 | 3 | 3 |
3 | 7 | 1997.68 | 25 | 11.47 | 3160 | 906 | 2.16 / 470.54 | 3 | 3 |
4 | 13 | 1545.20 | 35 | 12.67 | 2570 | 1140 | 3.30 / 471.68 | 3 | 7 |
5 | 13 | 326.00 | 35 | 13.69 | 862 | 413 | 3.71 / 472.09 | 3 | 11 |
6 | 13 | 65.36 | 35 | 13.91 | 561 | 273 | 3.98 / 472.36 | 3 | 11 |
7 | 8 | -0.08 | 190 | 13.62 | 473 | 1224 | 5.21 / 473.59 | 3 | 16 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 28 | 13.93 | 591 | 231 | 0.23 / 463.50 | 3 | 4 |
2 | 3 | 1027.60 | 1 | 12.44 | 1888 | 23 | 0.25 / 463.52 | 3 | 3 |
3 | 12 | 2001.60 | 30 | 10.99 | 3081 | 1016 | 1.27 / 464.54 | 3 | 3 |
4 | 7 | 1998.20 | 25 | 11.52 | 3152 | 908 | 2.18 / 465.45 | 3 | 3 |
5 | 13 | 1546.80 | 35 | 12.66 | 2571 | 1139 | 3.32 / 466.59 | 3 | 7 |
6 | 13 | 545.72 | 35 | 13.51 | 1165 | 551 | 3.87 / 467.14 | 3 | 13 |
7 | 8 | -0.12 | 190 | 13.64 | 481 | 1247 | 5.11 / 468.38 | 3 | 10 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 29 | 13.88 | 599 | 241 | 0.24 / 458.51 | 3 | 4 |
2 | 3 | 971.04 | -1 | 13.88 | 599 | 0 | 0.00 / 458.51 | 3 | 4 |
3 | 12 | 2002.00 | 30 | 10.98 | 3098 | 1020 | 1.26 / 459.53 | 3 | 3 |
4 | 7 | 1998.64 | 25 | 11.50 | 3175 | 913 | 2.17 / 460.45 | 3 | 3 |
5 | 13 | 1551.96 | 35 | 12.65 | 2595 | 1149 | 3.32 / 461.59 | 3 | 6 |
6 | 13 | 361.32 | 35 | 13.65 | 918 | 439 | 3.76 / 462.03 | 3 | 11 |
7 | 8 | 0.12 | 190 | 13.64 | 477 | 1236 | 5.00 / 463.27 | 3 | 18 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 28 | 13.90 | 600 | 234 | 0.23 / 453.42 | 3 | 4 |
2 | 3 | 1042.08 | 1 | 12.88 | 1920 | 25 | 0.26 / 453.44 | 3 | 3 |
3 | 12 | 2000.64 | 30 | 10.97 | 3088 | 1016 | 1.27 / 454.46 | 3 | 3 |
4 | 7 | 1997.20 | 25 | 11.50 | 3136 | 902 | 2.18 / 455.36 | 3 | 3 |
5 | 13 | 1546.40 | 34 | 12.71 | 2566 | 1109 | 3.28 / 456.47 | 3 | 7 |
6 | 13 | 551.72 | 34 | 13.51 | 1190 | 547 | 3.83 / 457.01 | 3 | 12 |
7 | 8 | 0.12 | 190 | 13.63 | 485 | 1256 | 5.09 / 458.27 | 3 | 9 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 28 | 13.89 | 605 | 235 | 0.24 / 448.35 | 3 | 4 |
2 | 12 | 2003.20 | 30 | 10.94 | 3096 | 1016 | 1.25 / 449.37 | 3 | 3 |
3 | 7 | 1999.92 | 25 | 11.47 | 3149 | 903 | 2.15 / 450.27 | 3 | 3 |
4 | 13 | 1546.00 | 34 | 12.71 | 2558 | 1105 | 3.26 / 451.38 | 3 | 7 |
5 | 13 | 552.52 | 34 | 13.49 | 1203 | 552 | 3.81 / 451.93 | 3 | 13 |
6 | 8 | 0.20 | 190 | 13.63 | 484 | 1253 | 5.06 / 453.18 | 3 | 12 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 27 | 13.88 | 604 | 226 | 0.23 / 442.84 | 3 | 4 |
2 | 3 | 1036.84 | 1 | 12.77 | 1924 | 25 | 0.25 / 442.87 | 3 | 3 |
3 | 12 | 2002.44 | 30 | 10.98 | 3094 | 1019 | 1.27 / 443.89 | 3 | 3 |
4 | 7 | 1999.16 | 25 | 11.49 | 3151 | 905 | 2.18 / 444.79 | 3 | 4 |
5 | 13 | 1536.20 | 34 | 12.72 | 2539 | 1098 | 3.27 / 445.89 | 3 | 7 |
6 | 13 | 556.92 | 34 | 13.50 | 1187 | 545 | 3.82 / 446.44 | 3 | 13 |
7 | 13 | 17.36 | 34 | 13.95 | 513 | 243 | 4.06 / 446.68 | 3 | 8 |
8 | 13 | 6.64 | 34 | 13.79 | 501 | 235 | 4.30 / 446.91 | 3 | 8 |
9 | 8 | 0.00 | 190 | 13.40 | 473 | 1204 | 5.50 / 448.12 | 3 | 18 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 26 | 13.84 | 617 | 222 | 0.22 / 437.57 | 3 | 6 |
2 | 12 | 2002.08 | 30 | 11.07 | 3096 | 1028 | 1.25 / 438.60 | 3 | 3 |
3 | 7 | 1998.32 | 25 | 11.47 | 3168 | 908 | 2.16 / 439.51 | 3 | 3 |
4 | 13 | 1535.96 | 34 | 12.66 | 2578 | 1110 | 3.27 / 440.62 | 3 | 7 |
5 | 13 | 541.08 | 34 | 13.51 | 1156 | 531 | 3.80 / 441.15 | 3 | 12 |
6 | 13 | 18.08 | 34 | 13.94 | 515 | 244 | 4.04 / 441.39 | 3 | 6 |
7 | 8 | -0.08 | 190 | 13.53 | 477 | 1226 | 5.27 / 442.62 | 3 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 28 | 13.87 | 612 | 238 | 0.24 / 432.34 | 3 | 7 |
2 | 3 | 957.40 | -1 | 13.87 | 612 | 0 | 0.00 / 432.34 | 3 | 7 |
3 | 7 | 2003.20 | 45 | 11.18 | 3129 | 1574 | 1.81 / 433.92 | 3 | 3 |
4 | 13 | 1791.16 | 33 | 12.45 | 2886 | 1186 | 3.00 / 435.10 | 3 | 6 |
5 | 13 | 816.56 | 33 | 13.27 | 1545 | 677 | 3.67 / 435.78 | 3 | 12 |
6 | 13 | 85.52 | 5 | 13.96 | 578 | 40 | 3.71 / 435.82 | 3 | 10 |
7 | 13 | 60.96 | 5 | 13.95 | 578 | 40 | 3.75 / 435.86 | 3 | 10 |
8 | 13 | 40.80 | 5 | 13.95 | 555 | 39 | 3.79 / 435.90 | 3 | 8 |
9 | 13 | 4.24 | 33 | 13.91 | 503 | 231 | 4.02 / 436.13 | 3 | 10 |
10 | 8 | 0.16 | 190 | 13.47 | 476 | 1218 | 5.24 / 437.35 | 3 | 11 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 26 | 13.86 | 611 | 220 | 0.22 / 426.93 | 3 | 6 |
2 | 3 | 1042.84 | 1 | 12.99 | 1920 | 25 | 0.25 / 426.95 | 3 | 3 |
3 | 7 | 2002.32 | 46 | 11.17 | 3163 | 1625 | 1.87 / 428.58 | 3 | 3 |
4 | 13 | 1801.28 | 33 | 12.43 | 2921 | 1198 | 3.07 / 429.77 | 3 | 6 |
5 | 13 | 834.72 | 33 | 13.27 | 1546 | 677 | 3.75 / 430.45 | 3 | 11 |
6 | 13 | 96.48 | 5 | 13.96 | 615 | 43 | 3.79 / 430.49 | 3 | 10 |
7 | 13 | 68.76 | 5 | 13.97 | 584 | 41 | 3.83 / 430.54 | 3 | 10 |
8 | 13 | 55.16 | 5 | 13.92 | 577 | 40 | 3.87 / 430.58 | 3 | 10 |
9 | 13 | 47.16 | 5 | 13.91 | 565 | 39 | 3.91 / 430.61 | 3 | 9 |
10 | 13 | 43.48 | 5 | 13.87 | 558 | 39 | 3.95 / 430.65 | 3 | 9 |
11 | 13 | 17.84 | 33 | 13.88 | 518 | 237 | 4.18 / 430.89 | 3 | 9 |
12 | 8 | -0.20 | 190 | 13.43 | 476 | 1215 | 5.40 / 432.11 | 3 | 15 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 26 | 13.89 | 618 | 223 | 0.22 / 422.04 | 3 | 8 |
2 | 7 | 2003.08 | 40 | 11.20 | 3153 | 1413 | 1.64 / 423.45 | 8 | 3 |
3 | 13 | 1802.72 | 33 | 12.47 | 2866 | 1179 | 2.82 / 424.63 | 3 | 5 |
4 | 13 | 865.84 | 33 | 13.23 | 1622 | 708 | 3.52 / 425.34 | 3 | 11 |
5 | 13 | 170.52 | 5 | 13.94 | 695 | 48 | 3.57 / 425.39 | 3 | 10 |
6 | 13 | 100.56 | 5 | 13.94 | 629 | 44 | 3.62 / 425.43 | 3 | 10 |
7 | 13 | 42.08 | 5 | 13.96 | 558 | 39 | 3.65 / 425.47 | 3 | 8 |
8 | 8 | 0.48 | 190 | 13.58 | 479 | 1236 | 4.89 / 426.71 | 3 | 11 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 25 | 13.90 | 620 | 215 | 0.22 / 416.95 | 3 | 9 |
2 | 3 | 1029.48 | 1 | 12.48 | 1884 | 24 | 0.24 / 416.98 | 3 | 3 |
3 | 7 | 2002.80 | 40 | 11.25 | 3140 | 1413 | 1.65 / 418.39 | 3 | 3 |
4 | 13 | 1795.96 | 33 | 12.45 | 2886 | 1186 | 2.84 / 419.58 | 3 | 6 |
5 | 13 | 849.12 | 33 | 13.25 | 1584 | 693 | 3.53 / 420.27 | 3 | 11 |
6 | 13 | 106.08 | 5 | 13.97 | 625 | 44 | 3.57 / 420.31 | 3 | 10 |
7 | 13 | 73.68 | 5 | 13.95 | 604 | 42 | 3.62 / 420.36 | 3 | 10 |
8 | 13 | 5.48 | 33 | 13.91 | 515 | 236 | 3.85 / 420.59 | 3 | 8 |
9 | 8 | 0.12 | 190 | 13.45 | 479 | 1224 | 5.08 / 421.82 | 3 | 16 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 26 | 13.85 | 612 | 220 | 0.22 / 412.06 | 3 | 9 |
2 | 3 | 956.96 | -1 | 13.85 | 612 | 0 | 0.00 / 412.06 | 3 | 9 |
3 | 7 | 2001.20 | 40 | 11.19 | 3144 | 1407 | 1.63 / 413.46 | 3 | 3 |
4 | 13 | 1804.68 | 33 | 12.45 | 2889 | 1187 | 2.81 / 414.65 | 3 | 5 |
5 | 13 | 857.92 | 33 | 13.25 | 1591 | 696 | 3.51 / 415.35 | 3 | 12 |
6 | 13 | 105.68 | 5 | 13.99 | 600 | 42 | 3.55 / 415.39 | 3 | 10 |
7 | 13 | 71.56 | 5 | 13.96 | 579 | 40 | 3.59 / 415.43 | 3 | 10 |
8 | 13 | 47.20 | 5 | 13.96 | 556 | 39 | 3.63 / 415.47 | 3 | 9 |
9 | 13 | 43.48 | 5 | 13.93 | 557 | 39 | 3.67 / 415.51 | 3 | 10 |
10 | 8 | -0.08 | 190 | 13.59 | 477 | 1232 | 4.90 / 416.74 | 3 | 14 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 25 | 13.89 | 607 | 211 | 0.21 / 406.64 | 3 | 8 |
2 | 3 | 1033.32 | 1 | 12.71 | 1883 | 24 | 0.23 / 406.66 | 3 | 3 |
3 | 7 | 2004.56 | 40 | 11.14 | 3176 | 1415 | 1.65 / 408.08 | 3 | 3 |
4 | 13 | 1797.48 | 33 | 12.48 | 2873 | 1183 | 2.83 / 409.26 | 3 | 5 |
5 | 13 | 1072.64 | 33 | 13.10 | 1868 | 808 | 3.64 / 410.07 | 3 | 10 |
6 | 13 | 145.16 | 5 | 13.95 | 650 | 45 | 3.69 / 410.11 | 3 | 10 |
7 | 13 | 93.60 | 5 | 13.95 | 606 | 42 | 3.73 / 410.16 | 3 | 10 |
8 | 13 | 71.40 | 5 | 13.95 | 583 | 41 | 3.77 / 410.20 | 3 | 9 |
9 | 13 | 17.68 | 33 | 13.93 | 507 | 233 | 4.00 / 410.43 | 3 | 8 |
10 | 13 | 5.84 | 33 | 13.79 | 488 | 222 | 4.22 / 410.65 | 3 | 8 |
11 | 8 | 0.56 | 190 | 13.39 | 466 | 1186 | 5.41 / 411.84 | 3 | 15 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 26 | 13.89 | 619 | 224 | 0.22 / 401.43 | 3 | 9 |
2 | 3 | 963.04 | -1 | 13.89 | 619 | 0 | 0.00 / 401.43 | 3 | 9 |
3 | 7 | 2005.76 | 40 | 11.27 | 3149 | 1420 | 1.64 / 402.85 | 3 | 3 |
4 | 13 | 1808.20 | 33 | 12.46 | 2905 | 1194 | 2.84 / 404.05 | 3 | 5 |
5 | 13 | 1083.20 | 33 | 13.10 | 1889 | 817 | 3.65 / 404.86 | 3 | 11 |
6 | 13 | 100.92 | 5 | 13.99 | 587 | 41 | 3.70 / 404.90 | 3 | 10 |
7 | 13 | 72.36 | 5 | 13.95 | 581 | 41 | 3.74 / 404.94 | 3 | 9 |
8 | 13 | 55.96 | 5 | 13.93 | 565 | 39 | 3.78 / 404.98 | 3 | 10 |
9 | 13 | 17.28 | 33 | 13.92 | 507 | 233 | 4.01 / 405.22 | 3 | 8 |
10 | 8 | 0.08 | 190 | 13.53 | 471 | 1211 | 5.22 / 406.43 | 3 | 15 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 26 | 13.85 | 619 | 223 | 0.22 / 396.29 | 3 | 9 |
2 | 7 | 2002.36 | 40 | 11.27 | 3129 | 1411 | 1.63 / 397.70 | 3 | 3 |
3 | 13 | 1788.44 | 33 | 12.49 | 2858 | 1178 | 2.81 / 398.88 | 3 | 6 |
4 | 13 | 1065.08 | 33 | 13.11 | 1864 | 806 | 3.62 / 399.69 | 3 | 11 |
5 | 13 | 139.28 | 5 | 13.97 | 644 | 45 | 3.66 / 399.73 | 3 | 11 |
6 | 13 | 90.32 | 5 | 13.97 | 593 | 41 | 3.70 / 399.77 | 3 | 10 |
7 | 13 | 70.88 | 5 | 13.96 | 578 | 40 | 3.74 / 399.81 | 3 | 10 |
8 | 13 | 61.68 | 5 | 13.93 | 580 | 40 | 3.79 / 399.85 | 3 | 10 |
9 | 13 | 54.68 | 5 | 13.93 | 571 | 40 | 3.82 / 399.89 | 3 | 10 |
10 | 13 | 47.96 | 5 | 13.91 | 559 | 39 | 3.86 / 399.93 | 3 | 10 |
11 | 13 | 44.64 | 5 | 13.88 | 559 | 39 | 3.90 / 399.97 | 3 | 10 |
12 | 13 | 41.68 | 5 | 13.88 | 549 | 38 | 3.94 / 400.01 | 3 | 10 |
13 | 8 | -0.16 | 190 | 13.58 | 465 | 1200 | 5.14 / 401.21 | 3 | 16 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 25 | 13.89 | 622 | 216 | 0.22 / 391.37 | 3 | 10 |
2 | 3 | 1030.84 | 1 | 12.79 | 1883 | 24 | 0.24 / 391.39 | 3 | 3 |
3 | 7 | 2004.08 | 40 | 11.22 | 3146 | 1412 | 1.65 / 392.80 | 3 | 3 |
4 | 13 | 1788.00 | 33 | 12.51 | 2861 | 1181 | 2.83 / 393.98 | 3 | 5 |
5 | 13 | 830.24 | 33 | 13.29 | 1550 | 680 | 3.51 / 394.66 | 3 | 11 |
6 | 13 | 161.32 | 5 | 13.96 | 671 | 47 | 3.56 / 394.71 | 3 | 10 |
7 | 13 | 96.00 | 5 | 13.98 | 614 | 43 | 3.60 / 394.75 | 3 | 10 |
8 | 13 | 45.56 | 5 | 13.98 | 549 | 38 | 3.64 / 394.79 | 3 | 9 |
9 | 13 | 43.68 | 5 | 13.94 | 546 | 38 | 3.68 / 394.83 | 3 | 9 |
10 | 13 | 41.12 | 5 | 13.94 | 542 | 38 | 3.72 / 394.87 | 3 | 8 |
11 | 8 | 0.32 | 190 | 13.59 | 465 | 1201 | 4.92 / 396.07 | 3 | 13 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 27 | 13.87 | 619 | 232 | 0.23 / 386.33 | 3 | 9 |
2 | 3 | 928.24 | -1 | 13.87 | 619 | 0 | 0.00 / 386.33 | 3 | 9 |
3 | 3 | 960.24 | -1 | 13.87 | 619 | 0 | 0.00 / 386.33 | 3 | 9 |
4 | 7 | 2004.92 | 40 | 11.27 | 3137 | 1414 | 1.65 / 387.75 | 9 | 3 |
5 | 13 | 1807.76 | 33 | 12.48 | 2902 | 1195 | 2.84 / 388.94 | 3 | 6 |
6 | 13 | 1081.60 | 33 | 13.10 | 1901 | 822 | 3.66 / 389.77 | 3 | 11 |
7 | 13 | 86.20 | 5 | 13.99 | 592 | 41 | 3.70 / 389.81 | 3 | 10 |
8 | 13 | 62.76 | 5 | 13.98 | 579 | 40 | 3.74 / 389.85 | 3 | 9 |
9 | 13 | 51.76 | 5 | 13.95 | 560 | 39 | 3.78 / 389.89 | 3 | 9 |
10 | 13 | 45.92 | 5 | 13.93 | 557 | 39 | 3.82 / 389.93 | 3 | 10 |
11 | 8 | 0.24 | 190 | 13.58 | 475 | 1226 | 5.05 / 391.15 | 3 | 12 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 26 | 13.92 | 611 | 221 | 0.22 / 381.20 | 3 | 8 |
2 | 3 | 1051.52 | 1 | 13.33 | 1928 | 26 | 0.25 / 381.22 | 3 | 3 |
3 | 7 | 2007.84 | 40 | 11.31 | 3155 | 1427 | 1.67 / 382.65 | 3 | 3 |
4 | 13 | 1823.08 | 33 | 12.49 | 2917 | 1202 | 2.88 / 383.85 | 3 | 6 |
5 | 13 | 868.32 | 33 | 13.25 | 1618 | 707 | 3.58 / 384.56 | 3 | 12 |
6 | 13 | 67.96 | 5 | 14.00 | 565 | 40 | 3.62 / 384.60 | 3 | 10 |
7 | 13 | 54.56 | 5 | 13.96 | 564 | 39 | 3.66 / 384.64 | 3 | 10 |
8 | 13 | 47.08 | 5 | 13.91 | 559 | 39 | 3.70 / 384.68 | 3 | 10 |
9 | 13 | 2.60 | 33 | 13.93 | 499 | 229 | 3.93 / 384.91 | 3 | 10 |
10 | 8 | 0.20 | 190 | 13.49 | 467 | 1197 | 5.13 / 386.10 | 3 | 16 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 27 | 13.85 | 616 | 230 | 0.23 / 376.07 | 3 | 8 |
2 | 3 | 959.92 | -1 | 13.85 | 616 | 0 | 0.00 / 376.07 | 3 | 8 |
3 | 7 | 2004.04 | 40 | 11.26 | 3134 | 1412 | 1.64 / 377.48 | 8 | 3 |
4 | 13 | 1807.20 | 33 | 12.50 | 2858 | 1179 | 2.82 / 378.66 | 3 | 5 |
5 | 13 | 878.52 | 33 | 13.27 | 1607 | 704 | 3.52 / 379.36 | 3 | 11 |
6 | 13 | 70.92 | 5 | 13.99 | 557 | 39 | 3.56 / 379.40 | 3 | 9 |
7 | 13 | 57.28 | 5 | 13.96 | 571 | 40 | 3.60 / 379.44 | 3 | 8 |
8 | 13 | 44.08 | 5 | 13.93 | 558 | 39 | 3.64 / 379.48 | 3 | 8 |
9 | 13 | 21.80 | 5 | 13.94 | 535 | 37 | 3.68 / 379.52 | 3 | 7 |
10 | 13 | 17.40 | 33 | 13.88 | 516 | 236 | 3.92 / 379.76 | 3 | 7 |
11 | 8 | 0.80 | 190 | 13.50 | 475 | 1218 | 5.13 / 380.97 | 3 | 9 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 24 | 13.93 | 609 | 204 | 0.20 / 370.94 | 3 | 8 |
2 | 10 | 1006.40 | 3 | 13.78 | 1822 | 75 | 0.28 / 371.02 | 3 | 7 |
3 | 7 | 2005.24 | 40 | 11.24 | 3155 | 1418 | 1.70 / 372.44 | 3 | 3 |
4 | 13 | 1813.16 | 33 | 12.49 | 2920 | 1204 | 2.90 / 373.64 | 3 | 5 |
5 | 13 | 867.72 | 33 | 13.29 | 1580 | 693 | 3.59 / 374.33 | 3 | 10 |
6 | 13 | 101.00 | 5 | 13.99 | 597 | 42 | 3.64 / 374.37 | 3 | 9 |
7 | 13 | 68.56 | 5 | 13.98 | 565 | 39 | 3.68 / 374.41 | 3 | 9 |
8 | 13 | 16.92 | 33 | 13.95 | 513 | 236 | 3.91 / 374.65 | 3 | 8 |
9 | 8 | 0.12 | 190 | 13.50 | 464 | 1190 | 5.10 / 375.84 | 3 | 11 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 28 | 13.87 | 606 | 235 | 0.24 / 366.14 | 3 | 9 |
2 | 3 | 897.84 | -2 | 13.87 | 606 | 0 | 0.00 / 366.14 | 3 | 9 |
3 | 3 | 965.76 | -1 | 13.87 | 606 | 0 | 0.00 / 366.14 | 3 | 9 |
4 | 7 | 2003.36 | 40 | 11.15 | 3169 | 1413 | 1.65 / 367.56 | 9 | 3 |
5 | 13 | 1807.00 | 33 | 12.49 | 2903 | 1197 | 2.85 / 368.75 | 3 | 5 |
6 | 13 | 844.32 | 33 | 13.29 | 1574 | 690 | 3.54 / 369.44 | 3 | 11 |
7 | 13 | 97.12 | 5 | 13.97 | 598 | 42 | 3.58 / 369.49 | 3 | 10 |
8 | 13 | 66.28 | 5 | 13.98 | 578 | 40 | 3.62 / 369.53 | 3 | 8 |
9 | 8 | 0.24 | 190 | 13.66 | 467 | 1212 | 4.83 / 370.74 | 3 | 12 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 28 | 13.90 | 610 | 237 | 0.24 / 360.59 | 3 | 7 |
2 | 7 | 2002.16 | 40 | 11.15 | 3144 | 1402 | 1.64 / 361.99 | 7 | 3 |
3 | 13 | 1798.80 | 33 | 12.51 | 2900 | 1197 | 2.84 / 363.19 | 3 | 6 |
4 | 13 | 1062.16 | 33 | 13.13 | 1881 | 815 | 3.65 / 364.00 | 3 | 11 |
5 | 13 | 91.80 | 5 | 13.99 | 584 | 41 | 3.69 / 364.05 | 3 | 10 |
6 | 13 | 69.32 | 5 | 13.98 | 579 | 40 | 3.73 / 364.09 | 3 | 10 |
7 | 13 | 59.40 | 5 | 13.97 | 565 | 39 | 3.77 / 364.13 | 3 | 9 |
8 | 13 | 52.68 | 5 | 13.94 | 556 | 39 | 3.81 / 364.16 | 3 | 10 |
9 | 13 | 48.08 | 5 | 13.92 | 547 | 38 | 3.85 / 364.20 | 3 | 10 |
10 | 13 | 45.16 | 5 | 13.90 | 550 | 38 | 3.89 / 364.24 | 3 | 10 |
11 | 13 | 42.04 | 5 | 13.88 | 547 | 38 | 3.93 / 364.28 | 3 | 10 |
12 | 13 | 18.04 | 33 | 13.87 | 514 | 235 | 4.16 / 364.51 | 3 | 10 |
13 | 13 | 8.88 | 33 | 13.75 | 500 | 227 | 4.39 / 364.74 | 3 | 10 |
14 | 8 | 0.08 | 190 | 13.37 | 460 | 1169 | 5.56 / 365.91 | 3 | 14 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 27 | 13.93 | 602 | 226 | 0.23 / 355.62 | 3 | 7 |
2 | 7 | 2001.56 | 41 | 11.24 | 3168 | 1460 | 1.69 / 357.08 | 3 | 3 |
3 | 13 | 1805.12 | 33 | 12.51 | 2911 | 1202 | 2.89 / 358.28 | 3 | 6 |
4 | 13 | 1077.72 | 33 | 13.14 | 1892 | 820 | 3.71 / 359.10 | 3 | 11 |
5 | 13 | 47.48 | 5 | 14.02 | 535 | 38 | 3.75 / 359.14 | 3 | 9 |
6 | 8 | 0.08 | 190 | 13.66 | 467 | 1212 | 4.96 / 360.35 | 3 | 10 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 27 | 13.96 | 590 | 222 | 0.22 / 350.49 | 3 | 6 |
2 | 7 | 2002.36 | 40 | 11.14 | 3160 | 1408 | 1.63 / 351.89 | 6 | 3 |
3 | 13 | 1786.36 | 33 | 12.55 | 2841 | 1177 | 2.81 / 353.07 | 3 | 6 |
4 | 13 | 1038.68 | 33 | 13.17 | 1817 | 790 | 3.60 / 353.86 | 3 | 10 |
5 | 13 | 90.44 | 5 | 14.00 | 571 | 40 | 3.64 / 353.90 | 3 | 9 |
6 | 13 | 66.56 | 5 | 13.98 | 568 | 40 | 3.68 / 353.94 | 3 | 8 |
7 | 13 | 52.64 | 5 | 13.97 | 562 | 39 | 3.72 / 353.98 | 3 | 8 |
8 | 13 | 5.72 | 33 | 13.97 | 492 | 227 | 3.94 / 354.21 | 3 | 7 |
9 | 8 | 0.12 | 190 | 13.53 | 462 | 1188 | 5.13 / 355.39 | 3 | 9 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 28 | 13.93 | 610 | 238 | 0.24 / 345.51 | 3 | 6 |
2 | 3 | 971.76 | -1 | 13.93 | 610 | 0 | 0.00 / 345.51 | 3 | 6 |
3 | 7 | 2001.80 | 40 | 11.12 | 3150 | 1401 | 1.64 / 346.92 | 3 | 3 |
4 | 13 | 1801.32 | 33 | 12.55 | 2840 | 1176 | 2.82 / 348.09 | 3 | 6 |
5 | 13 | 846.64 | 33 | 13.33 | 1549 | 681 | 3.50 / 348.77 | 3 | 11 |
6 | 13 | 93.16 | 5 | 14.01 | 580 | 41 | 3.54 / 348.81 | 3 | 9 |
7 | 13 | 65.92 | 5 | 14.00 | 562 | 39 | 3.58 / 348.85 | 3 | 9 |
8 | 13 | 16.32 | 33 | 13.97 | 499 | 230 | 3.81 / 349.08 | 3 | 7 |
9 | 8 | 0.04 | 190 | 13.54 | 459 | 1181 | 4.99 / 350.26 | 3 | 13 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 30 | 13.94 | 591 | 247 | 0.25 / 340.46 | 3 | 5 |
2 | 3 | 954.32 | -1 | 13.94 | 591 | 0 | 0.00 / 340.46 | 3 | 5 |
3 | 7 | 2005.44 | 40 | 11.16 | 3144 | 1403 | 1.65 / 341.87 | 5 | 3 |
4 | 13 | 1805.96 | 33 | 12.57 | 2861 | 1187 | 2.84 / 343.05 | 3 | 6 |
5 | 13 | 1048.84 | 33 | 13.19 | 1823 | 793 | 3.63 / 343.85 | 3 | 10 |
6 | 13 | 87.00 | 5 | 14.04 | 559 | 39 | 3.67 / 343.88 | 3 | 9 |
7 | 13 | 65.40 | 5 | 14.01 | 567 | 40 | 3.71 / 343.92 | 3 | 9 |
8 | 13 | 53.00 | 5 | 13.98 | 557 | 39 | 3.75 / 343.96 | 3 | 8 |
9 | 13 | 46.24 | 5 | 13.95 | 553 | 39 | 3.79 / 344.00 | 3 | 8 |
10 | 13 | 43.32 | 5 | 13.91 | 546 | 38 | 3.83 / 344.04 | 3 | 9 |
11 | 13 | 40.08 | 5 | 13.89 | 547 | 38 | 3.86 / 344.08 | 3 | 9 |
12 | 8 | 0.16 | 190 | 13.66 | 462 | 1199 | 5.06 / 345.28 | 3 | 8 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 28 | 13.96 | 574 | 224 | 0.22 / 335.56 | 3 | 4 |
2 | 3 | 1058.36 | 2 | 13.55 | 1914 | 52 | 0.28 / 335.62 | 3 | 5 |
3 | 7 | 2003.76 | 40 | 11.21 | 3146 | 1411 | 1.69 / 337.03 | 3 | 3 |
4 | 13 | 1797.16 | 33 | 12.58 | 2839 | 1179 | 2.87 / 338.21 | 3 | 6 |
5 | 13 | 856.36 | 33 | 13.33 | 1553 | 683 | 3.55 / 338.89 | 3 | 11 |
6 | 13 | 96.28 | 5 | 14.00 | 579 | 41 | 3.59 / 338.93 | 3 | 10 |
7 | 13 | 66.96 | 5 | 14.00 | 557 | 39 | 3.63 / 338.97 | 3 | 9 |
8 | 13 | 53.36 | 5 | 13.97 | 558 | 39 | 3.67 / 339.01 | 3 | 9 |
9 | 8 | 0.24 | 190 | 13.69 | 464 | 1207 | 4.87 / 340.21 | 3 | 9 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 29 | 13.93 | 577 | 233 | 0.23 / 330.82 | 3 | 5 |
2 | 3 | 972.28 | -1 | 13.93 | 577 | 0 | 0.00 / 330.82 | 3 | 5 |
3 | 7 | 2002.72 | 40 | 11.14 | 3148 | 1403 | 1.64 / 332.22 | 3 | 4 |
4 | 13 | 1797.56 | 33 | 12.56 | 2871 | 1190 | 2.83 / 333.41 | 3 | 6 |
5 | 13 | 853.44 | 33 | 13.34 | 1565 | 689 | 3.51 / 334.10 | 3 | 13 |
6 | 13 | 92.56 | 5 | 14.04 | 569 | 40 | 3.55 / 334.14 | 3 | 11 |
7 | 8 | -0.08 | 190 | 13.70 | 460 | 1197 | 4.75 / 335.34 | 3 | 17 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 28 | 13.99 | 563 | 221 | 0.22 / 325.77 | 3 | 5 |
2 | 7 | 2004.48 | 40 | 11.15 | 3157 | 1408 | 1.63 / 327.17 | 3 | 4 |
3 | 13 | 1807.48 | 33 | 12.57 | 2879 | 1194 | 2.82 / 328.37 | 3 | 6 |
4 | 13 | 865.76 | 33 | 13.34 | 1587 | 699 | 3.52 / 329.07 | 3 | 13 |
5 | 13 | 94.48 | 5 | 14.01 | 580 | 41 | 3.56 / 329.11 | 3 | 11 |
6 | 13 | 68.32 | 5 | 13.98 | 564 | 39 | 3.60 / 329.15 | 3 | 10 |
7 | 13 | 53.12 | 5 | 13.97 | 555 | 39 | 3.64 / 329.19 | 3 | 10 |
8 | 13 | 16.44 | 33 | 13.97 | 496 | 229 | 3.87 / 329.42 | 3 | 8 |
9 | 8 | 0.12 | 190 | 13.60 | 454 | 1173 | 5.04 / 330.59 | 3 | 18 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 30 | 13.96 | 594 | 249 | 0.25 / 320.66 | 3 | 5 |
2 | 3 | 953.60 | -1 | 13.96 | 594 | 0 | 0.00 / 320.66 | 3 | 5 |
3 | 7 | 2004.36 | 40 | 11.18 | 3125 | 1397 | 1.65 / 322.06 | 5 | 4 |
4 | 13 | 1795.64 | 33 | 12.56 | 2894 | 1200 | 2.85 / 323.26 | 3 | 7 |
5 | 13 | 1060.52 | 33 | 13.18 | 1861 | 809 | 3.66 / 324.07 | 3 | 12 |
6 | 13 | 133.20 | 5 | 14.00 | 649 | 45 | 3.70 / 324.11 | 3 | 12 |
7 | 13 | 82.56 | 5 | 14.01 | 601 | 42 | 3.74 / 324.16 | 3 | 11 |
8 | 13 | 17.76 | 33 | 13.99 | 502 | 232 | 3.97 / 324.39 | 3 | 8 |
9 | 8 | 0.08 | 190 | 13.56 | 450 | 1159 | 5.13 / 325.55 | 3 | 17 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 30 | 14.00 | 568 | 239 | 0.24 / 315.48 | 3 | 5 |
2 | 7 | 2003.52 | 40 | 11.14 | 3144 | 1401 | 1.64 / 316.88 | 5 | 3 |
3 | 13 | 1819.48 | 33 | 12.60 | 2877 | 1196 | 2.84 / 318.08 | 3 | 6 |
4 | 13 | 1070.36 | 33 | 13.20 | 1873 | 816 | 3.65 / 318.90 | 3 | 11 |
5 | 13 | 83.04 | 5 | 14.04 | 584 | 41 | 3.69 / 318.94 | 3 | 10 |
6 | 13 | 63.80 | 5 | 14.03 | 571 | 40 | 3.73 / 318.98 | 3 | 9 |
7 | 13 | 52.24 | 5 | 14.01 | 552 | 39 | 3.77 / 319.02 | 3 | 9 |
8 | 13 | 16.00 | 33 | 13.98 | 497 | 229 | 4.00 / 319.24 | 3 | 7 |
9 | 8 | -0.40 | 190 | 13.57 | 453 | 1168 | 5.17 / 320.41 | 3 | 12 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 29 | 13.99 | 569 | 231 | 0.23 / 310.73 | 3 | 5 |
2 | 3 | 1034.88 | 1 | 13.47 | 1930 | 26 | 0.26 / 310.75 | 3 | 3 |
3 | 7 | 2002.64 | 40 | 11.27 | 3136 | 1414 | 1.67 / 312.17 | 3 | 3 |
4 | 13 | 1788.16 | 33 | 12.63 | 2835 | 1182 | 2.85 / 313.35 | 3 | 6 |
5 | 13 | 835.68 | 33 | 13.38 | 1535 | 678 | 3.53 / 314.03 | 3 | 12 |
6 | 13 | 94.56 | 5 | 14.04 | 570 | 40 | 3.57 / 314.07 | 3 | 10 |
7 | 8 | 0.08 | 190 | 13.76 | 450 | 1176 | 4.75 / 315.24 | 3 | 9 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 30 | 14.03 | 565 | 238 | 0.24 / 306.07 | 3 | 6 |
2 | 3 | 954.24 | -1 | 14.03 | 565 | 0 | 0.00 / 306.07 | 3 | 6 |
3 | 7 | 2000.96 | 40 | 11.23 | 3138 | 1410 | 1.65 / 307.48 | 6 | 4 |
4 | 13 | 1797.80 | 33 | 12.63 | 2853 | 1189 | 2.84 / 308.66 | 3 | 7 |
5 | 13 | 669.00 | 33 | 13.52 | 1305 | 582 | 3.42 / 309.25 | 3 | 13 |
6 | 13 | 99.64 | 5 | 14.03 | 588 | 41 | 3.46 / 309.29 | 3 | 12 |
7 | 13 | 45.52 | 5 | 14.03 | 531 | 37 | 3.50 / 309.33 | 3 | 10 |
8 | 8 | 0.36 | 190 | 13.74 | 449 | 1172 | 4.67 / 310.50 | 3 | 14 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 27 | 14.02 | 569 | 215 | 0.22 / 301.17 | 3 | 5 |
2 | 10 | 1001.68 | 3 | 13.97 | 1814 | 76 | 0.29 / 301.25 | 3 | 10 |
3 | 7 | 2003.40 | 40 | 11.34 | 3131 | 1420 | 1.71 / 302.67 | 10 | 4 |
4 | 13 | 1798.76 | 33 | 12.62 | 2910 | 1212 | 2.92 / 303.88 | 3 | 7 |
5 | 13 | 823.28 | 33 | 13.40 | 1526 | 675 | 3.60 / 304.56 | 3 | 13 |
6 | 13 | 86.56 | 5 | 14.03 | 584 | 41 | 3.64 / 304.60 | 3 | 12 |
7 | 13 | 62.84 | 5 | 14.01 | 561 | 39 | 3.68 / 304.64 | 3 | 11 |
8 | 8 | 0.32 | 190 | 13.73 | 457 | 1192 | 4.87 / 305.83 | 3 | 14 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 28 | 14.03 | 565 | 222 | 0.22 / 296.36 | 3 | 5 |
2 | 3 | 972.92 | -1 | 14.03 | 565 | 0 | 0.00 / 296.36 | 3 | 5 |
3 | 7 | 2006.40 | 40 | 11.34 | 3124 | 1417 | 1.64 / 297.78 | 5 | 4 |
4 | 13 | 1819.96 | 33 | 12.63 | 2864 | 1194 | 2.83 / 298.97 | 3 | 7 |
5 | 13 | 836.20 | 33 | 13.39 | 1546 | 683 | 3.52 / 299.66 | 3 | 13 |
6 | 13 | 96.32 | 5 | 14.02 | 586 | 41 | 3.56 / 299.70 | 3 | 13 |
7 | 13 | 45.32 | 5 | 14.02 | 541 | 38 | 3.59 / 299.74 | 3 | 10 |
8 | 13 | 42.04 | 5 | 14.02 | 540 | 38 | 3.63 / 299.77 | 3 | 10 |
9 | 8 | -0.24 | 190 | 13.72 | 454 | 1183 | 4.82 / 300.96 | 3 | 15 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 28 | 13.96 | 579 | 226 | 0.23 / 291.16 | 3 | 5 |
2 | 7 | 2003.00 | 40 | 11.35 | 3123 | 1418 | 1.64 / 292.58 | 3 | 4 |
3 | 13 | 1804.40 | 33 | 12.64 | 2866 | 1195 | 2.84 / 293.77 | 3 | 6 |
4 | 13 | 863.16 | 33 | 13.38 | 1575 | 695 | 3.54 / 294.47 | 3 | 12 |
5 | 13 | 101.56 | 5 | 14.02 | 601 | 42 | 3.58 / 294.51 | 3 | 11 |
6 | 13 | 73.76 | 5 | 14.02 | 590 | 41 | 3.62 / 294.55 | 3 | 11 |
7 | 13 | 16.60 | 33 | 14.01 | 496 | 229 | 3.85 / 294.78 | 3 | 10 |
8 | 13 | 4.04 | 33 | 13.87 | 476 | 218 | 4.07 / 295.00 | 3 | 14 |
9 | 8 | 0.04 | 190 | 13.52 | 445 | 1143 | 5.21 / 296.14 | 3 | 12 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 28 | 14.01 | 566 | 222 | 0.22 / 286.20 | 3 | 5 |
2 | 7 | 2001.00 | 40 | 11.45 | 3118 | 1428 | 1.65 / 287.62 | 3 | 4 |
3 | 13 | 1796.00 | 33 | 12.67 | 2864 | 1197 | 2.85 / 288.82 | 3 | 7 |
4 | 13 | 846.80 | 33 | 13.41 | 1548 | 685 | 3.53 / 289.51 | 3 | 13 |
5 | 13 | 70.48 | 33 | 14.00 | 545 | 252 | 3.78 / 289.76 | 3 | 12 |
6 | 8 | 0.36 | 190 | 13.70 | 451 | 1174 | 4.96 / 290.93 | 3 | 17 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 27 | 14.00 | 578 | 218 | 0.22 / 281.14 | 3 | 6 |
2 | 3 | 1039.12 | 1 | 13.75 | 1915 | 26 | 0.24 / 281.17 | 3 | 3 |
3 | 7 | 2003.36 | 41 | 11.49 | 3127 | 1473 | 1.72 / 282.64 | 3 | 4 |
4 | 13 | 1811.76 | 33 | 12.67 | 2877 | 1203 | 2.92 / 283.85 | 3 | 7 |
5 | 13 | 850.56 | 33 | 13.41 | 1556 | 689 | 3.61 / 284.53 | 3 | 13 |
6 | 13 | 82.32 | 33 | 13.99 | 563 | 260 | 3.87 / 284.79 | 3 | 12 |
7 | 8 | -0.28 | 190 | 13.70 | 453 | 1179 | 5.05 / 285.97 | 3 | 14 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 28 | 14.00 | 558 | 219 | 0.22 / 276.16 | 3 | 5 |
2 | 3 | 967.68 | -1 | 14.00 | 558 | 0 | 0.00 / 276.16 | 3 | 5 |
3 | 7 | 2002.96 | 40 | 11.58 | 3115 | 1443 | 1.66 / 277.60 | 5 | 4 |
4 | 13 | 1800.12 | 33 | 12.69 | 2865 | 1200 | 2.86 / 278.80 | 3 | 8 |
5 | 13 | 834.12 | 33 | 13.43 | 1530 | 678 | 3.54 / 279.48 | 3 | 14 |
6 | 13 | 74.32 | 33 | 14.00 | 561 | 259 | 3.80 / 279.74 | 3 | 12 |
7 | 8 | 0.08 | 190 | 13.69 | 456 | 1186 | 4.98 / 280.93 | 3 | 14 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 27 | 13.99 | 591 | 223 | 0.22 / 270.84 | 3 | 7 |
2 | 3 | 1020.64 | 1 | 13.28 | 1922 | 26 | 0.25 / 270.86 | 3 | 3 |
3 | 7 | 2002.88 | 40 | 11.70 | 3122 | 1461 | 1.71 / 272.32 | 3 | 4 |
4 | 13 | 1798.92 | 33 | 12.69 | 2881 | 1206 | 2.92 / 273.53 | 3 | 7 |
5 | 13 | 849.20 | 33 | 13.42 | 1556 | 689 | 3.61 / 274.22 | 3 | 13 |
6 | 13 | 84.64 | 5 | 14.03 | 574 | 40 | 3.65 / 274.26 | 3 | 11 |
7 | 13 | 61.80 | 5 | 14.05 | 559 | 39 | 3.68 / 274.30 | 3 | 10 |
8 | 13 | 52.12 | 5 | 14.00 | 546 | 38 | 3.72 / 274.34 | 3 | 10 |
9 | 13 | 45.72 | 5 | 13.97 | 536 | 37 | 3.76 / 274.37 | 3 | 10 |
10 | 13 | 17.00 | 33 | 13.98 | 488 | 225 | 3.99 / 274.60 | 3 | 9 |
11 | 13 | 3.92 | 33 | 13.86 | 469 | 215 | 4.20 / 274.81 | 3 | 13 |
12 | 8 | 0.12 | 190 | 13.52 | 439 | 1128 | 5.33 / 275.94 | 3 | 16 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 26 | 14.02 | 589 | 215 | 0.21 / 265.84 | 3 | 8 |
2 | 3 | 1024.56 | 1 | 13.67 | 1897 | 26 | 0.24 / 265.87 | 3 | 3 |
3 | 7 | 2002.20 | 40 | 11.66 | 3124 | 1457 | 1.70 / 267.33 | 3 | 4 |
4 | 13 | 1790.52 | 33 | 12.70 | 2846 | 1193 | 2.89 / 268.52 | 3 | 8 |
5 | 13 | 827.04 | 33 | 13.44 | 1533 | 680 | 3.57 / 269.20 | 3 | 14 |
6 | 13 | 89.68 | 5 | 14.03 | 571 | 40 | 3.61 / 269.24 | 3 | 12 |
7 | 13 | 3.56 | 33 | 14.06 | 469 | 218 | 3.83 / 269.46 | 3 | 9 |
8 | 8 | 0.00 | 190 | 13.65 | 446 | 1157 | 4.98 / 270.61 | 3 | 15 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 28 | 14.00 | 591 | 232 | 0.23 / 261.05 | 3 | 10 |
2 | 3 | 947.00 | -1 | 14.00 | 591 | 0 | 0.00 / 261.05 | 3 | 10 |
3 | 7 | 2005.28 | 40 | 11.68 | 3137 | 1466 | 1.70 / 262.51 | 10 | 4 |
4 | 13 | 1807.92 | 33 | 12.71 | 2868 | 1203 | 2.90 / 263.72 | 3 | 8 |
5 | 13 | 837.04 | 33 | 13.43 | 1557 | 690 | 3.59 / 264.41 | 3 | 14 |
6 | 13 | 63.00 | 5 | 14.03 | 546 | 38 | 3.63 / 264.45 | 3 | 12 |
7 | 8 | -0.16 | 190 | 13.74 | 453 | 1183 | 4.81 / 265.63 | 3 | 12 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 25 | 14.00 | 597 | 209 | 0.21 / 256.11 | 3 | 9 |
2 | 3 | 1092.44 | 2 | 14.00 | 1957 | 55 | 0.26 / 256.16 | 3 | 10 |
3 | 3 | 1019.12 | 1 | 13.75 | 1892 | 26 | 0.29 / 256.19 | 3 | 3 |
4 | 7 | 2001.40 | 40 | 11.83 | 3127 | 1480 | 1.77 / 257.67 | 3 | 4 |
5 | 13 | 1790.08 | 33 | 12.72 | 2898 | 1216 | 2.99 / 258.88 | 3 | 8 |
6 | 13 | 787.60 | 33 | 13.49 | 1475 | 657 | 3.64 / 259.54 | 3 | 14 |
7 | 13 | 83.64 | 5 | 14.06 | 585 | 41 | 3.68 / 259.58 | 3 | 12 |
8 | 13 | 60.24 | 5 | 14.04 | 568 | 40 | 3.72 / 259.62 | 3 | 12 |
9 | 8 | 0.16 | 190 | 13.72 | 459 | 1197 | 4.92 / 260.82 | 3 | 11 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 23 | 14.04 | 577 | 186 | 0.19 / 251.10 | 3 | 9 |
2 | 3 | 1048.48 | 1 | 13.98 | 1913 | 27 | 0.21 / 251.13 | 3 | 4 |
3 | 7 | 2001.44 | 40 | 11.94 | 3111 | 1486 | 1.70 / 252.61 | 3 | 4 |
4 | 13 | 1799.00 | 33 | 12.75 | 2845 | 1197 | 2.90 / 253.81 | 3 | 7 |
5 | 13 | 814.36 | 33 | 13.49 | 1501 | 668 | 3.56 / 254.48 | 3 | 13 |
6 | 13 | 86.60 | 5 | 14.05 | 564 | 40 | 3.60 / 254.52 | 3 | 12 |
7 | 13 | 3.88 | 33 | 14.05 | 481 | 223 | 3.83 / 254.74 | 3 | 12 |
8 | 8 | 0.04 | 190 | 13.65 | 445 | 1154 | 4.98 / 255.90 | 3 | 20 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 8 | 14.02 | 599 | 67 | 0.07 / 245.89 | 3 | 5 |
2 | 10 | 1016.36 | 6 | 14.00 | 1850 | 155 | 0.22 / 246.05 | 3 | 9 |
3 | 10 | 1062.80 | 4 | 13.93 | 1889 | 105 | 0.33 / 246.15 | 3 | 10 |
4 | 3 | 1148.20 | 4 | 14.02 | 1996 | 112 | 0.44 / 246.26 | 3 | 10 |
5 | 3 | 1026.00 | 1 | 14.04 | 1920 | 27 | 0.47 / 246.29 | 3 | 3 |
6 | 7 | 2003.36 | 40 | 11.89 | 3136 | 1491 | 1.96 / 247.78 | 3 | 4 |
7 | 13 | 1592.80 | 33 | 12.93 | 2611 | 1114 | 3.07 / 248.90 | 3 | 9 |
8 | 13 | 658.96 | 33 | 13.59 | 1306 | 586 | 3.66 / 249.48 | 3 | 14 |
9 | 13 | 99.12 | 5 | 14.02 | 590 | 41 | 3.70 / 249.52 | 3 | 12 |
10 | 13 | 4.36 | 33 | 14.04 | 482 | 223 | 3.92 / 249.75 | 3 | 10 |
11 | 8 | 0.20 | 190 | 13.65 | 451 | 1170 | 5.09 / 250.92 | 3 | 18 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 7 | 14.16 | 630 | 62 | 0.06 / 241.02 | 3 | 9 |
2 | 3 | 1044.28 | 1 | 13.99 | 1924 | 27 | 0.09 / 241.04 | 3 | 3 |
3 | 7 | 2002.64 | 40 | 11.92 | 3127 | 1491 | 1.58 / 242.53 | 3 | 4 |
4 | 13 | 1786.40 | 33 | 12.75 | 2879 | 1211 | 2.79 / 243.74 | 3 | 7 |
5 | 13 | 783.56 | 33 | 13.51 | 1478 | 659 | 3.45 / 244.40 | 3 | 13 |
6 | 13 | 79.68 | 5 | 14.04 | 569 | 40 | 3.49 / 244.44 | 3 | 11 |
7 | 13 | 4.28 | 33 | 14.05 | 474 | 220 | 3.71 / 244.66 | 3 | 11 |
8 | 8 | 0.12 | 190 | 13.66 | 447 | 1160 | 4.87 / 245.82 | 3 | 18 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 12 | 14.14 | 614 | 104 | 0.10 / 237.52 | 3 | 11 |
2 | 3 | 842.72 | -3 | 14.14 | 614 | 0 | 0.00 / 237.52 | 3 | 11 |
3 | 3 | 934.04 | -1 | 14.14 | 614 | 0 | 0.00 / 237.52 | 3 | 11 |
4 | 7 | 2002.64 | 40 | 11.97 | 3139 | 1503 | 1.61 / 239.03 | 11 | 4 |
5 | 13 | 1789.60 | 33 | 12.75 | 2891 | 1216 | 2.82 / 240.24 | 3 | 7 |
6 | 13 | 800.32 | 33 | 13.50 | 1508 | 672 | 3.50 / 240.91 | 3 | 14 |
7 | 13 | 81.32 | 5 | 14.02 | 567 | 40 | 3.54 / 240.95 | 3 | 12 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 12 | 14.14 | 610 | 104 | 0.10 / 233.98 | 3 | 10 |
2 | 3 | 1027.60 | 1 | 13.97 | 1903 | 27 | 0.13 / 234.01 | 3 | 3 |
3 | 7 | 2004.84 | 40 | 12.16 | 3134 | 1524 | 1.65 / 235.53 | 3 | 4 |
4 | 13 | 1787.64 | 33 | 12.78 | 2892 | 1220 | 2.87 / 236.75 | 3 | 7 |
5 | 13 | 795.24 | 33 | 13.50 | 1500 | 668 | 3.54 / 237.42 | 3 | 14 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 8 | 14.16 | 608 | 69 | 0.07 / 230.30 | 3 | 8 |
2 | 10 | 1008.12 | 3 | 14.14 | 1775 | 75 | 0.14 / 230.37 | 3 | 10 |
3 | 3 | 1038.44 | 1 | 14.07 | 1909 | 27 | 0.17 / 230.40 | 3 | 3 |
4 | 7 | 2002.52 | 40 | 12.23 | 3158 | 1545 | 1.72 / 231.95 | 3 | 4 |
5 | 13 | 1597.20 | 33 | 12.95 | 2626 | 1122 | 2.84 / 233.07 | 3 | 9 |
6 | 13 | 849.40 | 33 | 13.48 | 1551 | 690 | 3.53 / 233.76 | 3 | 13 |
7 | 13 | 84.96 | 5 | 14.03 | 574 | 40 | 3.57 / 233.80 | 3 | 12 |
8 | 13 | 60.84 | 5 | 14.02 | 564 | 40 | 3.61 / 233.84 | 3 | 11 |
9 | 13 | 45.04 | 5 | 13.99 | 542 | 38 | 3.65 / 233.88 | 3 | 10 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 12 | 14.15 | 615 | 104 | 0.10 / 227.01 | 3 | 11 |
2 | 3 | 894.88 | -2 | 14.15 | 615 | 0 | 0.00 / 227.01 | 3 | 11 |
3 | 3 | 953.48 | -1 | 14.15 | 615 | 0 | 0.00 / 227.01 | 3 | 11 |
4 | 7 | 2001.88 | 40 | 12.28 | 3120 | 1533 | 1.64 / 228.54 | 11 | 5 |
5 | 13 | 1560.24 | 33 | 13.01 | 2552 | 1096 | 2.73 / 229.63 | 3 | 9 |
6 | 13 | 599.64 | 33 | 13.65 | 1234 | 556 | 3.29 / 230.19 | 3 | 14 |
7 | 13 | 90.16 | 5 | 14.03 | 574 | 40 | 3.33 / 230.23 | 3 | 12 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 9 | 14.16 | 630 | 80 | 0.08 / 223.29 | 3 | 9 |
2 | 3 | 1103.12 | 3 | 14.12 | 1941 | 82 | 0.16 / 223.38 | 3 | 10 |
3 | 7 | 2002.08 | 41 | 12.43 | 3133 | 1597 | 1.76 / 224.97 | 3 | 5 |
4 | 13 | 1782.96 | 33 | 12.84 | 2879 | 1220 | 2.98 / 226.19 | 3 | 8 |
5 | 13 | 807.16 | 33 | 13.52 | 1503 | 671 | 3.65 / 226.86 | 3 | 13 |
6 | 13 | 58.12 | 5 | 14.03 | 536 | 38 | 3.69 / 226.90 | 3 | 10 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 13 | 14.19 | 627 | 116 | 0.12 / 219.81 | 3 | 11 |
2 | 3 | 875.48 | -2 | 14.19 | 627 | 0 | 0.00 / 219.81 | 3 | 11 |
3 | 3 | 925.92 | -1 | 14.19 | 627 | 0 | 0.00 / 219.81 | 3 | 11 |
4 | 7 | 2000.84 | 40 | 12.41 | 3156 | 1567 | 1.68 / 221.38 | 11 | 5 |
5 | 13 | 1569.28 | 33 | 13.02 | 2604 | 1119 | 2.80 / 222.50 | 3 | 9 |
6 | 13 | 824.44 | 33 | 13.52 | 1529 | 682 | 3.48 / 223.18 | 3 | 14 |
7 | 13 | 43.76 | 5 | 14.06 | 517 | 36 | 3.52 / 223.21 | 3 | 10 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 9 | 14.16 | 604 | 77 | 0.08 / 216.22 | 3 | 10 |
2 | 10 | 1006.44 | 3 | 14.17 | 1769 | 75 | 0.15 / 216.30 | 3 | 11 |
3 | 3 | 1035.52 | 1 | 14.16 | 1920 | 27 | 0.18 / 216.32 | 3 | 3 |
4 | 7 | 2002.04 | 40 | 12.54 | 3147 | 1579 | 1.76 / 217.90 | 3 | 6 |
5 | 13 | 1800.56 | 33 | 12.87 | 2902 | 1233 | 2.99 / 219.14 | 3 | 8 |
6 | 13 | 600.36 | 33 | 13.65 | 1241 | 559 | 3.55 / 219.69 | 3 | 15 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 25 | 14.10 | 602 | 212 | 0.21 / 212.56 | 3 | 12 |
2 | 3 | 595.84 | -8 | 14.10 | 602 | 0 | 0.00 / 212.56 | 3 | 12 |
3 | 3 | 812.52 | -4 | 14.10 | 602 | 0 | 0.00 / 212.56 | 3 | 12 |
4 | 7 | 2004.64 | 40 | 12.59 | 3130 | 1576 | 1.79 / 214.13 | 12 | 6 |
5 | 13 | 1797.24 | 33 | 12.89 | 2892 | 1230 | 3.02 / 215.36 | 3 | 9 |
6 | 13 | 804.96 | 33 | 13.53 | 1497 | 668 | 3.69 / 216.03 | 3 | 15 |
7 | 13 | 55.44 | 5 | 14.04 | 547 | 38 | 3.73 / 216.07 | 3 | 11 |
8 | 13 | 43.36 | 5 | 14.03 | 547 | 38 | 3.76 / 216.11 | 3 | 12 |
9 | 13 | 40.24 | 5 | 14.03 | 543 | 38 | 3.80 / 216.14 | 3 | 12 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 12 | 14.09 | 588 | 99 | 0.10 / 208.50 | 3 | 9 |
2 | 10 | 1002.04 | 6 | 14.11 | 1756 | 149 | 0.25 / 208.65 | 3 | 11 |
3 | 10 | 1043.12 | 4 | 14.04 | 1838 | 103 | 0.35 / 208.75 | 3 | 12 |
4 | 3 | 1087.64 | 2 | 14.17 | 1906 | 54 | 0.41 / 208.81 | 3 | 10 |
5 | 3 | 1033.36 | 1 | 14.19 | 1888 | 27 | 0.43 / 208.83 | 3 | 3 |
6 | 7 | 2004.60 | 40 | 12.68 | 3125 | 1585 | 2.02 / 210.42 | 3 | 6 |
7 | 13 | 1794.96 | 33 | 12.90 | 2874 | 1223 | 3.24 / 211.64 | 3 | 9 |
8 | 13 | 790.12 | 33 | 13.56 | 1481 | 663 | 3.90 / 212.31 | 3 | 15 |
9 | 13 | 55.24 | 5 | 14.05 | 528 | 37 | 3.94 / 212.34 | 3 | 12 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 14 | 14.16 | 628 | 124 | 0.12 / 203.79 | 3 | 10 |
2 | 3 | 973.28 | -1 | 14.16 | 628 | 0 | 0.00 / 203.79 | 3 | 10 |
3 | 7 | 2003.60 | 40 | 12.74 | 3143 | 1602 | 1.73 / 205.40 | 10 | 5 |
4 | 13 | 1795.96 | 33 | 12.91 | 2886 | 1230 | 2.96 / 206.63 | 3 | 8 |
5 | 13 | 581.48 | 33 | 13.68 | 1205 | 544 | 3.50 / 207.17 | 3 | 14 |
6 | 13 | 86.16 | 5 | 14.05 | 572 | 40 | 3.54 / 207.21 | 3 | 13 |
7 | 8 | 0.32 | 190 | 13.80 | 455 | 1193 | 4.73 / 208.40 | 3 | 17 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 10 | 14.19 | 629 | 89 | 0.09 / 199.97 | 3 | 10 |
2 | 10 | 1033.40 | 3 | 14.19 | 1821 | 78 | 0.17 / 200.05 | 3 | 11 |
3 | 3 | 1019.40 | 1 | 14.18 | 1904 | 27 | 0.19 / 200.07 | 3 | 3 |
4 | 7 | 2001.84 | 41 | 12.76 | 3140 | 1643 | 1.84 / 201.71 | 3 | 6 |
5 | 13 | 1797.56 | 33 | 12.91 | 2882 | 1228 | 3.06 / 202.94 | 3 | 8 |
6 | 13 | 769.28 | 33 | 13.56 | 1451 | 649 | 3.71 / 203.59 | 3 | 14 |
7 | 13 | 74.40 | 5 | 14.03 | 554 | 39 | 3.75 / 203.63 | 3 | 11 |
8 | 13 | 57.08 | 5 | 14.04 | 552 | 39 | 3.79 / 203.67 | 3 | 11 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 26 | 14.06 | 610 | 223 | 0.22 / 196.52 | 3 | 12 |
2 | 3 | 593.52 | -8 | 14.06 | 610 | 0 | 0.00 / 196.52 | 3 | 12 |
3 | 3 | 803.24 | -4 | 14.06 | 610 | 0 | 0.00 / 196.52 | 3 | 12 |
4 | 7 | 2002.32 | 40 | 12.81 | 3119 | 1598 | 1.82 / 198.11 | 12 | 6 |
5 | 13 | 1579.12 | 33 | 13.10 | 2554 | 1104 | 2.93 / 199.22 | 3 | 10 |
6 | 13 | 591.16 | 33 | 13.70 | 1203 | 544 | 3.47 / 199.76 | 3 | 15 |
7 | 13 | 82.44 | 5 | 14.05 | 568 | 40 | 3.51 / 199.80 | 3 | 12 |
8 | 13 | 44.68 | 5 | 14.05 | 535 | 38 | 3.55 / 199.84 | 3 | 11 |
9 | 13 | 41.40 | 5 | 14.04 | 543 | 38 | 3.58 / 199.88 | 3 | 12 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 26 | 14.06 | 604 | 221 | 0.22 / 192.81 | 3 | 12 |
2 | 7 | 2001.08 | 40 | 12.84 | 3120 | 1602 | 1.82 / 194.42 | 12 | 6 |
3 | 13 | 1786.32 | 33 | 12.94 | 2873 | 1227 | 3.05 / 195.64 | 3 | 9 |
4 | 13 | 565.20 | 33 | 13.71 | 1176 | 532 | 3.58 / 196.17 | 3 | 15 |
5 | 13 | 83.52 | 5 | 14.03 | 570 | 40 | 3.62 / 196.21 | 3 | 13 |
6 | 13 | 63.68 | 5 | 14.00 | 568 | 40 | 3.66 / 196.25 | 3 | 13 |
7 | 13 | 53.04 | 5 | 14.01 | 558 | 39 | 3.70 / 196.29 | 3 | 11 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 26 | 14.06 | 594 | 217 | 0.22 / 188.09 | 3 | 12 |
2 | 7 | 2002.44 | 40 | 12.86 | 3123 | 1606 | 1.82 / 189.70 | 12 | 6 |
3 | 13 | 1564.76 | 33 | 13.09 | 2574 | 1112 | 2.94 / 190.81 | 3 | 11 |
4 | 13 | 597.80 | 33 | 13.69 | 1213 | 548 | 3.48 / 191.36 | 3 | 15 |
5 | 13 | 78.96 | 5 | 14.07 | 563 | 40 | 3.52 / 191.40 | 3 | 12 |
6 | 8 | 0.72 | 190 | 13.82 | 456 | 1197 | 4.72 / 192.59 | 3 | 15 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 25 | 14.10 | 596 | 210 | 0.21 / 183.38 | 3 | 12 |
2 | 3 | 1030.44 | 1 | 14.22 | 1875 | 27 | 0.24 / 183.41 | 3 | 3 |
3 | 7 | 2003.28 | 40 | 12.85 | 3120 | 1604 | 1.84 / 185.01 | 3 | 6 |
4 | 13 | 1575.64 | 33 | 13.11 | 2580 | 1116 | 2.96 / 186.13 | 3 | 10 |
5 | 13 | 613.80 | 33 | 13.68 | 1238 | 559 | 3.52 / 186.69 | 3 | 14 |
6 | 8 | 0.16 | 190 | 13.82 | 451 | 1184 | 4.70 / 187.87 | 3 | 11 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 26 | 14.11 | 586 | 215 | 0.21 / 178.86 | 3 | 11 |
2 | 3 | 972.00 | -1 | 14.11 | 586 | 0 | 0.00 / 178.86 | 3 | 11 |
3 | 7 | 2002.00 | 40 | 12.88 | 3117 | 1606 | 1.82 / 180.47 | 3 | 6 |
4 | 13 | 1582.88 | 33 | 13.14 | 2524 | 1094 | 2.92 / 181.56 | 3 | 10 |
5 | 13 | 401.80 | 33 | 13.85 | 940 | 430 | 3.34 / 181.99 | 3 | 14 |
6 | 8 | 0.00 | 190 | 13.86 | 448 | 1180 | 4.52 / 183.17 | 3 | 11 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 24 | 14.15 | 580 | 197 | 0.20 / 174.10 | 3 | 12 |
2 | 3 | 1059.60 | 2 | 14.25 | 1892 | 54 | 0.25 / 174.15 | 3 | 9 |
3 | 7 | 2003.40 | 40 | 12.86 | 3117 | 1603 | 1.85 / 175.75 | 3 | 7 |
4 | 13 | 1567.16 | 33 | 13.14 | 2542 | 1102 | 2.96 / 176.86 | 3 | 11 |
5 | 13 | 602.48 | 33 | 13.72 | 1221 | 553 | 3.51 / 177.41 | 3 | 15 |
6 | 13 | 86.52 | 5 | 14.06 | 567 | 40 | 3.55 / 177.45 | 3 | 13 |
7 | 13 | 61.88 | 5 | 14.07 | 557 | 39 | 3.59 / 177.49 | 3 | 12 |
8 | 8 | 0.16 | 190 | 13.84 | 441 | 1160 | 4.75 / 178.65 | 3 | 18 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 26 | 14.13 | 573 | 211 | 0.21 / 169.29 | 3 | 11 |
2 | 3 | 959.36 | -1 | 14.13 | 573 | 0 | 0.00 / 169.29 | 3 | 11 |
3 | 7 | 2002.36 | 40 | 12.92 | 3117 | 1611 | 1.82 / 170.90 | 11 | 7 |
4 | 13 | 1785.44 | 33 | 13.00 | 2843 | 1220 | 3.04 / 172.12 | 3 | 10 |
5 | 13 | 560.96 | 33 | 13.76 | 1163 | 528 | 3.57 / 172.65 | 3 | 15 |
6 | 13 | 79.56 | 5 | 14.10 | 533 | 38 | 3.61 / 172.69 | 3 | 12 |
7 | 13 | 43.68 | 5 | 14.08 | 534 | 38 | 3.64 / 172.72 | 3 | 12 |
8 | 8 | 0.16 | 190 | 13.84 | 447 | 1175 | 4.82 / 173.90 | 3 | 13 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 27 | 14.17 | 590 | 226 | 0.23 / 164.28 | 3 | 11 |
2 | 3 | 962.44 | -1 | 14.17 | 590 | 0 | 0.00 / 164.28 | 3 | 11 |
3 | 7 | 2002.52 | 41 | 12.93 | 3123 | 1656 | 1.88 / 165.94 | 3 | 7 |
4 | 13 | 1569.44 | 33 | 13.17 | 2552 | 1109 | 2.99 / 167.05 | 3 | 11 |
5 | 13 | 828.96 | 33 | 13.59 | 1514 | 679 | 3.67 / 167.73 | 3 | 15 |
6 | 13 | 7.68 | 33 | 14.14 | 462 | 216 | 3.89 / 167.94 | 3 | 9 |
7 | 8 | 0.36 | 190 | 13.81 | 434 | 1139 | 5.02 / 169.08 | 3 | 14 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 25 | 14.17 | 573 | 203 | 0.20 / 159.66 | 3 | 8 |
2 | 3 | 1049.20 | 1 | 14.29 | 1885 | 27 | 0.23 / 159.69 | 3 | 7 |
3 | 7 | 2002.88 | 40 | 12.94 | 3110 | 1610 | 1.84 / 161.30 | 3 | 6 |
4 | 13 | 1368.44 | 33 | 13.29 | 2255 | 989 | 2.83 / 162.29 | 3 | 12 |
5 | 13 | 681.04 | 33 | 13.70 | 1322 | 598 | 3.43 / 162.88 | 3 | 15 |
6 | 8 | 0.24 | 190 | 13.91 | 444 | 1173 | 4.60 / 164.06 | 3 | 17 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 28 | 14.17 | 575 | 228 | 0.23 / 155.15 | 3 | 10 |
2 | 3 | 943.56 | -1 | 14.17 | 575 | 0 | 0.00 / 155.15 | 3 | 10 |
3 | 3 | 970.88 | -1 | 14.17 | 575 | 0 | 0.00 / 155.15 | 3 | 10 |
4 | 7 | 2004.40 | 40 | 12.97 | 3114 | 1616 | 1.84 / 156.77 | 10 | 6 |
5 | 13 | 1389.88 | 33 | 13.28 | 2332 | 1022 | 2.87 / 157.79 | 3 | 11 |
6 | 13 | 482.28 | 33 | 13.84 | 1058 | 483 | 3.35 / 158.27 | 3 | 14 |
7 | 8 | -0.12 | 190 | 13.92 | 448 | 1185 | 4.53 / 159.46 | 3 | 16 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 28 | 14.21 | 553 | 220 | 0.22 / 150.65 | 3 | 8 |
2 | 7 | 2005.24 | 40 | 12.96 | 3117 | 1616 | 1.84 / 152.26 | 3 | 7 |
3 | 13 | 1397.40 | 33 | 13.31 | 2271 | 997 | 2.83 / 153.26 | 3 | 11 |
4 | 13 | 507.88 | 33 | 13.85 | 1093 | 500 | 3.33 / 153.76 | 3 | 16 |
5 | 8 | 0.24 | 190 | 13.92 | 440 | 1164 | 4.50 / 154.92 | 3 | 17 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 27 | 14.22 | 567 | 218 | 0.22 / 145.95 | 3 | 8 |
2 | 3 | 1020.44 | 1 | 14.23 | 1892 | 27 | 0.24 / 145.98 | 3 | 3 |
3 | 7 | 2002.80 | 40 | 12.99 | 3116 | 1619 | 1.86 / 147.59 | 3 | 7 |
4 | 13 | 1596.80 | 33 | 13.21 | 2581 | 1125 | 2.99 / 148.72 | 3 | 11 |
5 | 13 | 609.68 | 33 | 13.79 | 1224 | 557 | 3.55 / 149.28 | 3 | 16 |
6 | 8 | -0.04 | 190 | 13.94 | 434 | 1149 | 4.70 / 150.43 | 3 | 13 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 25 | 14.24 | 557 | 198 | 0.20 / 141.43 | 3 | 7 |
2 | 3 | 1072.84 | 2 | 14.35 | 1898 | 54 | 0.25 / 141.48 | 3 | 12 |
3 | 3 | 1021.60 | 1 | 14.20 | 1896 | 27 | 0.28 / 141.51 | 3 | 3 |
4 | 7 | 2001.64 | 40 | 13.01 | 3107 | 1617 | 1.90 / 143.13 | 3 | 7 |
5 | 13 | 1389.28 | 33 | 13.35 | 2250 | 991 | 2.89 / 144.12 | 3 | 12 |
6 | 13 | 470.08 | 33 | 13.90 | 1028 | 472 | 3.36 / 144.59 | 3 | 16 |
7 | 8 | 0.16 | 190 | 13.95 | 430 | 1140 | 4.50 / 145.73 | 3 | 15 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 29 | 14.21 | 560 | 231 | 0.23 / 137.00 | 3 | 7 |
2 | 3 | 905.04 | -2 | 14.21 | 560 | 0 | 0.00 / 137.00 | 3 | 7 |
3 | 3 | 970.84 | -1 | 14.21 | 560 | 0 | 0.00 / 137.00 | 3 | 7 |
4 | 7 | 2002.64 | 40 | 13.03 | 3087 | 1609 | 1.84 / 138.60 | 7 | 6 |
5 | 13 | 1373.12 | 33 | 13.36 | 2232 | 984 | 2.82 / 139.59 | 3 | 11 |
6 | 13 | 483.48 | 33 | 13.90 | 1059 | 486 | 3.31 / 140.07 | 3 | 15 |
7 | 8 | 0.56 | 190 | 13.97 | 436 | 1157 | 4.47 / 141.23 | 3 | 20 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 27 | 14.24 | 527 | 203 | 0.20 / 132.29 | 3 | 5 |
2 | 3 | 1044.84 | 1 | 14.34 | 1860 | 27 | 0.23 / 132.32 | 3 | 8 |
3 | 7 | 2002.64 | 40 | 13.03 | 3112 | 1622 | 1.85 / 133.94 | 3 | 7 |
4 | 13 | 1378.92 | 33 | 13.37 | 2228 | 983 | 2.83 / 134.92 | 3 | 11 |
5 | 13 | 490.12 | 33 | 13.91 | 1044 | 479 | 3.31 / 135.40 | 3 | 15 |
6 | 13 | 16.64 | 33 | 14.24 | 469 | 220 | 3.53 / 135.62 | 3 | 8 |
7 | 8 | -0.28 | 190 | 13.93 | 432 | 1143 | 4.68 / 136.76 | 3 | 15 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 27 | 14.26 | 551 | 212 | 0.21 / 127.66 | 3 | 6 |
2 | 7 | 2002.80 | 40 | 13.03 | 3110 | 1621 | 1.83 / 129.28 | 3 | 7 |
3 | 13 | 1369.16 | 33 | 13.37 | 2216 | 978 | 2.81 / 130.26 | 3 | 11 |
4 | 13 | 464.20 | 33 | 13.92 | 1030 | 473 | 3.28 / 130.73 | 3 | 15 |
5 | 13 | 17.92 | 33 | 14.25 | 470 | 221 | 3.50 / 130.95 | 3 | 8 |
6 | 8 | 0.40 | 190 | 13.93 | 430 | 1138 | 4.64 / 132.09 | 3 | 13 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 27 | 14.26 | 536 | 206 | 0.21 / 122.95 | 3 | 6 |
2 | 7 | 2002.80 | 40 | 13.05 | 3116 | 1627 | 1.83 / 124.58 | 3 | 7 |
3 | 13 | 1577.80 | 30 | 13.30 | 2528 | 1009 | 2.84 / 125.59 | 3 | 11 |
4 | 13 | 639.04 | 30 | 13.87 | 1208 | 503 | 3.34 / 126.09 | 3 | 15 |
5 | 13 | 61.52 | 30 | 14.24 | 505 | 216 | 3.56 / 126.31 | 3 | 11 |
6 | 8 | 0.04 | 190 | 13.98 | 428 | 1137 | 4.70 / 127.44 | 3 | 14 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 29 | 14.25 | 544 | 225 | 0.22 / 118.33 | 3 | 7 |
2 | 3 | 942.12 | -1 | 14.25 | 544 | 0 | 0.00 / 118.33 | 3 | 7 |
3 | 3 | 960.56 | -1 | 14.25 | 544 | 0 | 0.00 / 118.33 | 3 | 7 |
4 | 7 | 2003.28 | 40 | 13.02 | 3120 | 1625 | 1.85 / 119.95 | 7 | 7 |
5 | 13 | 1593.00 | 30 | 13.28 | 2551 | 1016 | 2.87 / 120.97 | 3 | 11 |
6 | 13 | 461.32 | 30 | 13.96 | 1008 | 422 | 3.29 / 121.39 | 3 | 15 |
7 | 13 | 49.44 | 30 | 14.25 | 510 | 218 | 3.51 / 121.61 | 3 | 12 |
8 | 8 | -0.24 | 190 | 13.95 | 430 | 1140 | 4.65 / 122.75 | 3 | 14 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 25 | 14.31 | 553 | 198 | 0.20 / 113.87 | 3 | 6 |
2 | 10 | 1020.96 | 3 | 14.46 | 1791 | 78 | 0.28 / 113.95 | 3 | 13 |
3 | 3 | 1041.68 | 1 | 14.38 | 1883 | 27 | 0.30 / 113.98 | 3 | 9 |
4 | 3 | 1019.24 | 1 | 14.26 | 1883 | 27 | 0.33 / 114.00 | 3 | 3 |
5 | 7 | 2001.76 | 40 | 13.05 | 3108 | 1622 | 1.95 / 115.62 | 3 | 8 |
6 | 13 | 1389.44 | 30 | 13.41 | 2235 | 899 | 2.85 / 116.52 | 3 | 12 |
7 | 13 | 490.24 | 30 | 13.96 | 1047 | 438 | 3.29 / 116.96 | 3 | 16 |
8 | 8 | 0.24 | 190 | 14.01 | 428 | 1139 | 4.43 / 118.10 | 3 | 15 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 28 | 14.24 | 552 | 220 | 0.22 / 109.29 | 3 | 8 |
2 | 3 | 947.72 | -1 | 14.24 | 552 | 0 | 0.00 / 109.29 | 3 | 8 |
3 | 3 | 973.64 | -1 | 14.24 | 552 | 0 | 0.00 / 109.29 | 3 | 8 |
4 | 7 | 2003.08 | 40 | 13.05 | 3113 | 1625 | 1.85 / 110.91 | 8 | 7 |
5 | 13 | 1574.96 | 30 | 13.31 | 2508 | 1001 | 2.85 / 111.92 | 3 | 11 |
6 | 13 | 637.44 | 30 | 13.86 | 1261 | 524 | 3.37 / 112.44 | 3 | 15 |
7 | 13 | 68.40 | 5 | 14.31 | 524 | 37 | 3.41 / 112.48 | 3 | 12 |
8 | 13 | 47.12 | 5 | 14.32 | 527 | 38 | 3.45 / 112.51 | 3 | 12 |
9 | 8 | -0.08 | 190 | 13.98 | 436 | 1158 | 4.60 / 113.67 | 3 | 16 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 26 | 14.30 | 539 | 200 | 0.20 / 104.53 | 3 | 7 |
2 | 3 | 1042.52 | 1 | 14.46 | 1843 | 27 | 0.23 / 104.56 | 3 | 11 |
3 | 7 | 2003.12 | 40 | 13.05 | 3095 | 1616 | 1.84 / 106.18 | 3 | 7 |
4 | 13 | 1586.72 | 30 | 13.30 | 2513 | 1003 | 2.85 / 107.18 | 3 | 10 |
5 | 13 | 633.00 | 30 | 13.88 | 1227 | 511 | 3.36 / 107.69 | 3 | 16 |
6 | 13 | 45.36 | 5 | 14.30 | 500 | 36 | 3.39 / 107.73 | 3 | 12 |
7 | 13 | 17.96 | 30 | 14.28 | 473 | 203 | 3.59 / 107.93 | 3 | 10 |
8 | 8 | 0.16 | 190 | 13.96 | 430 | 1141 | 4.74 / 109.07 | 3 | 15 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 26 | 14.28 | 550 | 204 | 0.20 / 100.27 | 3 | 11 |
2 | 7 | 2002.44 | 40 | 13.05 | 3097 | 1617 | 1.82 / 101.88 | 3 | 7 |
3 | 13 | 1376.48 | 30 | 13.40 | 2253 | 906 | 2.73 / 102.79 | 3 | 13 |
4 | 13 | 475.40 | 30 | 14.00 | 1000 | 420 | 3.15 / 103.21 | 3 | 16 |
5 | 8 | 0.04 | 190 | 14.03 | 422 | 1125 | 4.27 / 104.33 | 3 | 16 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 26 | 14.32 | 540 | 201 | 0.20 / 95.62 | 3 | 12 |
2 | 7 | 2003.68 | 40 | 13.04 | 3104 | 1619 | 1.82 / 97.24 | 3 | 8 |
3 | 13 | 1581.40 | 30 | 13.30 | 2537 | 1012 | 2.83 / 98.25 | 3 | 12 |
4 | 13 | 631.68 | 30 | 13.88 | 1217 | 507 | 3.34 / 98.76 | 3 | 16 |
5 | 13 | 6.16 | 30 | 14.33 | 431 | 185 | 3.52 / 98.95 | 3 | 11 |
6 | 8 | 0.04 | 190 | 13.96 | 421 | 1117 | 4.64 / 100.06 | 3 | 21 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 23 | 14.34 | 532 | 175 | 0.18 / 91.29 | 3 | 13 |
2 | 3 | 1075.08 | 2 | 14.48 | 1879 | 54 | 0.23 / 91.35 | 3 | 14 |
3 | 7 | 2001.84 | 40 | 13.06 | 3097 | 1618 | 1.85 / 92.97 | 3 | 8 |
4 | 13 | 1367.08 | 30 | 13.42 | 2234 | 899 | 2.75 / 93.87 | 3 | 13 |
5 | 13 | 491.12 | 30 | 14.00 | 1017 | 427 | 3.17 / 94.29 | 3 | 16 |
6 | 13 | 56.84 | 5 | 14.34 | 491 | 35 | 3.21 / 94.33 | 3 | 13 |
7 | 13 | 45.04 | 5 | 14.34 | 483 | 35 | 3.24 / 94.36 | 3 | 13 |
8 | 13 | 42.16 | 5 | 14.33 | 475 | 34 | 3.28 / 94.40 | 3 | 12 |
9 | 8 | 0.00 | 190 | 14.05 | 384 | 1025 | 4.30 / 95.42 | 3 | 13 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 1008.16 | 8 | 14.36 | 1710 | 196 | 0.20 / 86.54 | 3 | 10 |
2 | 10 | 1068.72 | 6 | 14.21 | 1807 | 154 | 0.35 / 86.70 | 3 | 12 |
3 | 10 | 1113.08 | 4 | 14.22 | 1888 | 107 | 0.46 / 86.80 | 3 | 12 |
4 | 3 | 1209.68 | 5 | 14.38 | 2023 | 145 | 0.60 / 86.95 | 3 | 13 |
5 | 3 | 1030.40 | 1 | 14.45 | 1860 | 27 | 0.63 / 86.98 | 3 | 7 |
6 | 7 | 2002.16 | 40 | 13.08 | 3088 | 1616 | 2.25 / 88.59 | 7 | 7 |
7 | 13 | 1579.32 | 30 | 13.30 | 2527 | 1008 | 3.25 / 89.60 | 3 | 11 |
8 | 13 | 628.36 | 30 | 13.91 | 1186 | 495 | 3.75 / 90.10 | 3 | 15 |
9 | 8 | 0.28 | 190 | 14.08 | 382 | 1022 | 4.77 / 91.12 | 3 | 15 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 880.28 | -2 | 0.00 | 0 | 0 | 0.00 / 82.27 | 3 | 3 |
2 | 3 | 924.24 | -1 | 0.00 | 0 | 0 | 0.00 / 82.27 | 3 | 3 |
3 | 7 | 2002.00 | 40 | 13.05 | 3115 | 1626 | 1.63 / 83.90 | 3 | 7 |
4 | 13 | 1577.52 | 30 | 13.30 | 2542 | 1014 | 2.64 / 84.91 | 3 | 11 |
5 | 13 | 438.80 | 30 | 14.04 | 941 | 396 | 3.04 / 85.31 | 3 | 15 |
6 | 13 | 42.44 | 5 | 14.37 | 452 | 32 | 3.07 / 85.34 | 3 | 12 |
7 | 8 | 0.24 | 190 | 14.09 | 375 | 1004 | 4.07 / 86.35 | 3 | 13 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 15 | 14.47 | 529 | 115 | 0.11 / 79.27 | 3 | 12 |
2 | 3 | 381.44 | -12 | 14.47 | 529 | 0 | 0.00 / 79.27 | 3 | 12 |
3 | 3 | 672.84 | -6 | 14.47 | 529 | 0 | 0.00 / 79.27 | 3 | 12 |
4 | 7 | 1989.28 | 40 | 13.07 | 3095 | 1618 | 1.73 / 80.89 | 12 | 7 |
5 | 13 | 1557.24 | 30 | 13.34 | 2478 | 992 | 2.72 / 81.88 | 3 | 11 |
6 | 13 | 432.48 | 30 | 14.05 | 938 | 395 | 3.12 / 82.27 | 3 | 15 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 10 | 1055.52 | 7 | 14.42 | 1777 | 179 | 0.18 / 76.00 | 3 | 12 |
2 | 10 | 1101.08 | 4 | 14.27 | 1906 | 109 | 0.29 / 76.11 | 3 | 12 |
3 | 3 | 1141.52 | 4 | 14.47 | 1931 | 112 | 0.40 / 76.22 | 3 | 13 |
4 | 7 | 2001.36 | 40 | 13.07 | 3112 | 1627 | 2.03 / 77.84 | 3 | 7 |
5 | 13 | 1370.92 | 30 | 13.47 | 2215 | 895 | 2.92 / 78.74 | 3 | 11 |
6 | 13 | 478.56 | 30 | 14.04 | 985 | 415 | 3.34 / 79.15 | 3 | 15 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 860.44 | -3 | 0.00 | 0 | 0 | 0.00 / 72.85 | 3 | 3 |
2 | 3 | 945.12 | -1 | 0.00 | 0 | 0 | 0.00 / 72.85 | 3 | 3 |
3 | 7 | 1993.60 | 40 | 13.09 | 3107 | 1627 | 1.63 / 74.47 | 3 | 7 |
4 | 13 | 1350.68 | 30 | 13.45 | 2201 | 888 | 2.51 / 75.36 | 3 | 12 |
5 | 13 | 472.68 | 30 | 14.03 | 998 | 420 | 2.93 / 75.78 | 3 | 16 |
6 | 13 | 55.88 | 5 | 14.37 | 482 | 35 | 2.97 / 75.82 | 3 | 13 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 883.48 | -2 | 0.00 | 0 | 0 | 0.00 / 69.89 | 3 | 3 |
2 | 3 | 944.36 | -1 | 0.00 | 0 | 0 | 0.00 / 69.89 | 3 | 3 |
3 | 7 | 2001.56 | 40 | 13.10 | 3115 | 1632 | 1.63 / 71.52 | 3 | 7 |
4 | 13 | 1390.44 | 30 | 13.45 | 2246 | 906 | 2.54 / 72.43 | 3 | 12 |
5 | 13 | 483.16 | 30 | 14.03 | 1003 | 422 | 2.96 / 72.85 | 3 | 16 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 807.28 | -4 | 0.00 | 0 | 0 | 0.00 / 66.83 | 3 | 3 |
2 | 3 | 917.92 | -2 | 0.00 | 0 | 0 | 0.00 / 66.83 | 3 | 3 |
3 | 7 | 2001.32 | 40 | 13.12 | 3104 | 1629 | 1.63 / 68.46 | 3 | 7 |
4 | 13 | 1374.12 | 30 | 13.46 | 2222 | 897 | 2.53 / 69.35 | 3 | 12 |
5 | 13 | 677.08 | 30 | 13.91 | 1276 | 532 | 3.06 / 69.89 | 3 | 16 |
Average= | 3.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 953.64 | -1 | 0.00 | 0 | 0 | 0.00 / 63.79 | 3 | 3 |
2 | 7 | 1997.68 | 40 | 13.13 | 3090 | 1623 | 1.62 / 65.42 | 3 | 7 |
3 | 13 | 1572.96 | 30 | 13.35 | 2538 | 1016 | 2.64 / 66.43 | 3 | 12 |
4 | 13 | 424.48 | 30 | 14.08 | 937 | 396 | 3.04 / 66.83 | 3 | 17 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 851.92 | -3 | 0.00 | 0 | 0 | 0.00 / 60.65 | 3 | 3 |
2 | 3 | 923.68 | -1 | 0.00 | 0 | 0 | 0.00 / 60.65 | 3 | 3 |
3 | 7 | 2001.40 | 41 | 13.14 | 3112 | 1677 | 1.68 / 62.33 | 3 | 7 |
4 | 13 | 1390.40 | 30 | 13.46 | 2282 | 921 | 2.60 / 63.25 | 3 | 12 |
5 | 13 | 701.56 | 30 | 13.90 | 1302 | 543 | 3.14 / 63.79 | 3 | 16 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 890.72 | -2 | 0.00 | 0 | 0 | 0.00 / 57.68 | 3 | 3 |
2 | 3 | 949.84 | -1 | 0.00 | 0 | 0 | 0.00 / 57.68 | 3 | 3 |
3 | 7 | 1999.04 | 40 | 13.15 | 3108 | 1635 | 1.63 / 59.31 | 3 | 8 |
4 | 13 | 1387.24 | 30 | 13.47 | 2269 | 917 | 2.55 / 60.23 | 3 | 13 |
5 | 13 | 484.44 | 30 | 14.06 | 1005 | 424 | 2.98 / 60.65 | 3 | 16 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 858.08 | -3 | 0.00 | 0 | 0 | 0.00 / 54.67 | 3 | 3 |
2 | 3 | 939.20 | -1 | 0.00 | 0 | 0 | 0.00 / 54.67 | 3 | 3 |
3 | 7 | 1988.84 | 41 | 13.16 | 3100 | 1673 | 1.67 / 56.34 | 3 | 8 |
4 | 13 | 1380.80 | 30 | 13.48 | 2253 | 911 | 2.58 / 57.25 | 3 | 13 |
5 | 13 | 488.80 | 30 | 14.06 | 1008 | 425 | 3.01 / 57.68 | 3 | 16 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 862.12 | -3 | 0.00 | 0 | 0 | 0.00 / 51.70 | 3 | 3 |
2 | 3 | 947.08 | -1 | 0.00 | 0 | 0 | 0.00 / 51.70 | 3 | 3 |
3 | 7 | 1995.00 | 40 | 13.17 | 3093 | 1629 | 1.63 / 53.32 | 3 | 8 |
4 | 13 | 1389.28 | 30 | 13.48 | 2280 | 922 | 2.55 / 54.25 | 3 | 13 |
5 | 13 | 476.56 | 30 | 14.07 | 997 | 421 | 2.97 / 54.67 | 3 | 16 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 845.96 | -3 | 0.00 | 0 | 0 | 0.00 / 48.74 | 3 | 3 |
2 | 3 | 921.20 | -1 | 0.00 | 0 | 0 | 0.00 / 48.74 | 3 | 3 |
3 | 7 | 1992.16 | 40 | 13.18 | 3086 | 1627 | 1.63 / 50.37 | 3 | 8 |
4 | 13 | 1375.56 | 30 | 13.50 | 2234 | 905 | 2.53 / 51.28 | 3 | 13 |
5 | 13 | 472.84 | 30 | 14.07 | 992 | 419 | 2.95 / 51.70 | 3 | 16 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 857.36 | -3 | 0.00 | 0 | 0 | 0.00 / 45.72 | 3 | 3 |
2 | 3 | 942.76 | -1 | 0.00 | 0 | 0 | 0.00 / 45.72 | 3 | 3 |
3 | 7 | 1987.20 | 40 | 13.18 | 3093 | 1631 | 1.63 / 47.35 | 3 | 8 |
4 | 13 | 1550.68 | 30 | 13.41 | 2502 | 1007 | 2.64 / 48.36 | 3 | 12 |
5 | 13 | 416.32 | 30 | 14.12 | 909 | 385 | 3.02 / 48.74 | 3 | 14 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 879.20 | -2 | 0.00 | 0 | 0 | 0.00 / 42.70 | 3 | 3 |
2 | 3 | 935.76 | -1 | 0.00 | 0 | 0 | 0.00 / 42.70 | 3 | 3 |
3 | 7 | 1994.80 | 40 | 13.20 | 3106 | 1640 | 1.64 / 44.34 | 3 | 8 |
4 | 13 | 1383.12 | 30 | 13.50 | 2254 | 913 | 2.55 / 45.25 | 3 | 13 |
5 | 13 | 491.48 | 30 | 14.05 | 1029 | 434 | 2.99 / 45.69 | 3 | 16 |
6 | 13 | 44.60 | 5 | 14.46 | 487 | 35 | 3.02 / 45.72 | 3 | 13 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 3 | 947.40 | -1 | 0.00 | 0 | 0 | 0.00 / 39.73 | 3 | 3 |
2 | 7 | 1988.72 | 40 | 13.20 | 3102 | 1638 | 1.64 / 41.36 | 3 | 9 |
3 | 13 | 1378.76 | 30 | 13.51 | 2223 | 901 | 2.54 / 42.27 | 3 | 13 |
4 | 13 | 482.36 | 30 | 14.04 | 1033 | 435 | 2.97 / 42.70 | 3 | 17 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 27 | 14.35 | 574 | 222 | 0.22 / 36.75 | 3 | 13 |
2 | 3 | 280.92 | -14 | 14.35 | 574 | 0 | 0.00 / 36.75 | 3 | 13 |
3 | 3 | 588.36 | -8 | 14.35 | 574 | 0 | 0.00 / 36.75 | 3 | 13 |
4 | 7 | 1980.88 | 40 | 13.21 | 3075 | 1625 | 1.85 / 38.38 | 13 | 9 |
5 | 13 | 1365.88 | 30 | 13.50 | 2213 | 896 | 2.74 / 39.28 | 3 | 13 |
6 | 13 | 465.52 | 30 | 14.07 | 985 | 416 | 3.16 / 39.69 | 3 | 16 |
7 | 13 | 55.20 | 5 | 14.52 | 495 | 36 | 3.20 / 39.73 | 3 | 13 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 28 | 14.34 | 533 | 214 | 0.21 / 33.51 | 3 | 15 |
2 | 3 | 971.16 | -1 | 14.34 | 533 | 0 | 0.00 / 33.51 | 3 | 15 |
3 | 7 | 1984.68 | 40 | 13.21 | 3086 | 1631 | 1.84 / 35.14 | 15 | 9 |
4 | 13 | 1563.08 | 30 | 13.39 | 2474 | 994 | 2.84 / 36.14 | 3 | 12 |
5 | 13 | 421.28 | 30 | 14.10 | 931 | 394 | 3.23 / 36.53 | 3 | 17 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 24 | 14.38 | 527 | 182 | 0.18 / 29.10 | 3 | 14 |
2 | 10 | 1035.12 | 3 | 14.53 | 1795 | 78 | 0.26 / 29.18 | 3 | 15 |
3 | 3 | 1020.48 | 1 | 14.50 | 1868 | 27 | 0.29 / 29.21 | 3 | 5 |
4 | 7 | 1962.88 | 40 | 13.22 | 3030 | 1602 | 1.89 / 30.81 | 3 | 9 |
5 | 13 | 1547.08 | 30 | 13.39 | 2485 | 998 | 2.89 / 31.81 | 3 | 13 |
6 | 13 | 589.48 | 30 | 13.98 | 1141 | 479 | 3.37 / 32.29 | 3 | 17 |
7 | 8 | 0.16 | 190 | 14.11 | 378 | 1013 | 4.38 / 33.30 | 3 | 15 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 28 | 14.36 | 509 | 205 | 0.20 / 25.03 | 3 | 12 |
2 | 3 | 896.40 | -2 | 14.36 | 509 | 0 | 0.00 / 25.03 | 3 | 12 |
3 | 3 | 952.12 | -1 | 14.36 | 509 | 0 | 0.00 / 25.03 | 3 | 12 |
4 | 7 | 1977.00 | 40 | 13.20 | 3076 | 1624 | 1.83 / 26.65 | 12 | 9 |
5 | 13 | 1366.56 | 30 | 13.46 | 2205 | 890 | 2.72 / 27.54 | 3 | 13 |
6 | 13 | 255.92 | 5 | 14.36 | 725 | 52 | 2.77 / 27.59 | 3 | 15 |
7 | 13 | 166.04 | 5 | 14.43 | 611 | 44 | 2.82 / 27.64 | 3 | 14 |
8 | 13 | 116.08 | 5 | 14.44 | 555 | 40 | 2.86 / 27.68 | 3 | 14 |
9 | 13 | 85.44 | 5 | 14.44 | 524 | 38 | 2.89 / 27.71 | 3 | 13 |
10 | 13 | 63.88 | 5 | 14.42 | 498 | 36 | 2.93 / 27.75 | 3 | 14 |
11 | 13 | 3.96 | 30 | 14.38 | 417 | 180 | 3.11 / 27.93 | 3 | 9 |
12 | 8 | -0.20 | 190 | 14.00 | 372 | 990 | 4.10 / 28.92 | 3 | 18 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 27 | 14.37 | 505 | 196 | 0.20 / 20.35 | 3 | 12 |
2 | 3 | 1045.80 | 1 | 14.54 | 1841 | 27 | 0.22 / 20.37 | 3 | 14 |
3 | 7 | 1969.68 | 74 | 12.90 | 3029 | 2891 | 3.11 / 23.26 | 3 | 10 |
4 | 13 | 468.80 | 25 | 14.12 | 968 | 342 | 3.46 / 23.61 | 3 | 16 |
5 | 13 | 75.08 | 5 | 14.51 | 488 | 35 | 3.49 / 23.64 | 3 | 14 |
6 | 13 | 57.68 | 5 | 14.48 | 470 | 34 | 3.53 / 23.68 | 3 | 13 |
7 | 13 | 40.92 | 5 | 14.47 | 452 | 33 | 3.56 / 23.71 | 3 | 13 |
8 | 13 | 17.24 | 25 | 14.41 | 405 | 146 | 3.70 / 23.85 | 3 | 11 |
9 | 8 | -0.04 | 190 | 14.03 | 363 | 968 | 4.67 / 24.82 | 3 | 17 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 23 | 14.40 | 498 | 165 | 0.16 / 15.98 | 3 | 9 |
2 | 10 | 1013.60 | 4 | 14.45 | 1764 | 102 | 0.27 / 16.08 | 3 | 14 |
3 | 7 | 1964.52 | 74 | 12.87 | 3018 | 2874 | 3.14 / 18.95 | 14 | 10 |
4 | 13 | 277.64 | 6 | 14.33 | 740 | 64 | 3.20 / 19.02 | 3 | 15 |
5 | 13 | 175.04 | 5 | 14.40 | 614 | 44 | 3.25 / 19.06 | 3 | 14 |
6 | 13 | 129.48 | 5 | 14.43 | 559 | 40 | 3.29 / 19.10 | 3 | 14 |
7 | 13 | 99.52 | 5 | 14.44 | 525 | 38 | 3.33 / 19.14 | 3 | 14 |
8 | 13 | 40.96 | 5 | 14.47 | 454 | 33 | 3.36 / 19.17 | 3 | 11 |
9 | 8 | 0.04 | 190 | 14.09 | 365 | 977 | 4.34 / 20.15 | 3 | 16 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 30 | 14.31 | 494 | 212 | 0.21 / 12.38 | 3 | 10 |
2 | 3 | 946.08 | -1 | 14.31 | 494 | 0 | 0.00 / 12.38 | 3 | 10 |
3 | 3 | 968.44 | -1 | 14.31 | 494 | 0 | 0.00 / 12.38 | 3 | 10 |
4 | 7 | 1503.64 | 74 | 13.12 | 2343 | 2275 | 2.49 / 14.65 | 10 | 10 |
5 | 13 | 286.24 | 6 | 14.30 | 755 | 65 | 2.55 / 14.72 | 3 | 15 |
6 | 13 | 167.80 | 5 | 14.38 | 600 | 43 | 2.59 / 14.76 | 3 | 13 |
7 | 13 | 104.56 | 5 | 14.41 | 512 | 37 | 2.63 / 14.80 | 3 | 12 |
8 | 13 | 75.80 | 5 | 14.41 | 481 | 35 | 2.67 / 14.83 | 3 | 11 |
9 | 13 | 58.56 | 5 | 14.41 | 459 | 33 | 2.70 / 14.87 | 3 | 11 |
10 | 8 | 0.36 | 190 | 14.07 | 354 | 946 | 3.65 / 15.81 | 3 | 13 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 28 | 14.27 | 493 | 197 | 0.20 / 8.54 | 3 | 10 |
2 | 3 | 1051.44 | 1 | 14.42 | 1838 | 27 | 0.22 / 8.56 | 3 | 13 |
3 | 7 | 1514.12 | 74 | 13.00 | 2393 | 2302 | 2.53 / 10.87 | 3 | 10 |
4 | 13 | 266.80 | 5 | 14.24 | 732 | 52 | 2.58 / 10.92 | 3 | 14 |
5 | 13 | 166.32 | 5 | 14.31 | 600 | 43 | 2.62 / 10.96 | 3 | 14 |
6 | 13 | 79.20 | 5 | 14.37 | 487 | 35 | 2.66 / 11.00 | 3 | 11 |
7 | 13 | 63.88 | 5 | 14.36 | 469 | 34 | 2.69 / 11.03 | 3 | 12 |
8 | 13 | 53.76 | 5 | 14.34 | 456 | 33 | 2.72 / 11.06 | 3 | 10 |
9 | 13 | 40.80 | 5 | 14.32 | 440 | 32 | 2.75 / 11.09 | 3 | 11 |
10 | 13 | 16.44 | 25 | 14.30 | 397 | 142 | 2.90 / 11.24 | 3 | 11 |
11 | 8 | -0.16 | 190 | 13.95 | 351 | 930 | 3.83 / 12.17 | 3 | 13 |
Average= | 3.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 23 | 14.33 | 480 | 158 | 0.16 / 4.68 | 3 | 10 |
2 | 10 | 1026.40 | 4 | 14.26 | 1751 | 100 | 0.26 / 4.78 | 3 | 12 |
3 | 3 | 1032.16 | 1 | 14.26 | 1822 | 26 | 0.28 / 4.81 | 3 | 12 |
4 | 7 | 1506.32 | 74 | 12.86 | 2392 | 2276 | 2.56 / 7.08 | 3 | 10 |
5 | 13 | 300.52 | 6 | 14.14 | 773 | 66 | 2.63 / 7.15 | 3 | 15 |
6 | 13 | 176.88 | 5 | 14.24 | 611 | 44 | 2.67 / 7.19 | 3 | 13 |
7 | 13 | 111.80 | 5 | 14.31 | 526 | 38 | 2.71 / 7.23 | 3 | 13 |
8 | 13 | 57.96 | 5 | 14.35 | 462 | 33 | 2.74 / 7.26 | 3 | 12 |
9 | 13 | 16.68 | 25 | 14.32 | 398 | 142 | 2.88 / 7.40 | 3 | 9 |
10 | 8 | 0.08 | 190 | 13.97 | 353 | 937 | 3.82 / 8.34 | 3 | 15 |
Average= | 2.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 23 | 14.45 | 467 | 155 | 0.16 / 1.73 | 3 | 8 |
2 | 3 | 1028.20 | 1 | 13.76 | 1841 | 25 | 0.18 / 1.75 | 3 | 10 |
3 | 7 | 1002.80 | 75 | 13.04 | 1642 | 1606 | 1.79 / 3.36 | 3 | 12 |
4 | 8 | -0.08 | 240 | 13.93 | 348 | 1163 | 2.95 / 4.52 | 3 | 15 |
Average= | 2.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 78.84 | 23 | 14.46 | 425 | 141 | 0.14 / 0.14 | 3 | 4 |
2 | 7 | 87.68 | 74 | 14.20 | 423 | 444 | 0.59 / 0.59 | 4 | 6 |
3 | 8 | 0.28 | 240 | 14.21 | 289 | 986 | 1.57 / 1.57 | 3 | 19 |
Average= | 1.57 (KJ/cycle) |