SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 30 | 15.20 | 473 | 216 | 0.22 / 95.71 | 2 | 16 |
2 | 3 | 789.12 | -11 | 15.58 | 0 | 0 | 0.00 / 95.71 | 2 | 16 |
3 | 3 | 1086.64 | 2 | 15.21 | 1807 | 55 | 0.27 / 95.76 | 2 | 23 |
4 | 7 | 2011.32 | 38 | 14.87 | 2860 | 1616 | 1.89 / 97.38 | 2 | 23 |
5 | 13 | 1446.32 | 18 | 14.97 | 2204 | 594 | 2.48 / 97.97 | 2 | 26 |
6 | 13 | 1021.20 | 18 | 15.06 | 1676 | 454 | 2.93 / 98.42 | 2 | 28 |
7 | 13 | 416.96 | 18 | 15.22 | 895 | 245 | 3.18 / 98.67 | 2 | 29 |
8 | 13 | 83.80 | 18 | 15.30 | 440 | 121 | 3.30 / 98.79 | 2 | 28 |
9 | 13 | 22.84 | 18 | 15.30 | 356 | 98 | 3.40 / 98.89 | 3 | 29 |
10 | 8 | -0.16 | 165 | 15.27 | 317 | 799 | 4.20 / 99.69 | 3 | 31 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 27 | 15.21 | 465 | 191 | 0.19 / 91.39 | 3 | 15 |
2 | 3 | 909.48 | -5 | 15.56 | 0 | 0 | 0.00 / 91.39 | 3 | 15 |
3 | 3 | 1210.24 | 6 | 15.15 | 1975 | 180 | 0.37 / 91.57 | 2 | 23 |
4 | 7 | 2007.44 | 38 | 14.89 | 2867 | 1622 | 1.99 / 93.19 | 2 | 23 |
5 | 13 | 1574.40 | 18 | 14.96 | 2361 | 636 | 2.63 / 93.83 | 2 | 26 |
6 | 13 | 916.68 | 18 | 15.10 | 1546 | 420 | 3.05 / 94.25 | 2 | 28 |
7 | 13 | 392.28 | 18 | 15.22 | 863 | 236 | 3.29 / 94.49 | 2 | 29 |
8 | 13 | 64.32 | 18 | 15.32 | 414 | 114 | 3.40 / 94.60 | 3 | 27 |
9 | 13 | 17.72 | 18 | 15.33 | 343 | 95 | 3.49 / 94.70 | 3 | 24 |
10 | 8 | -0.16 | 165 | 15.27 | 315 | 794 | 4.29 / 95.49 | 3 | 33 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 31 | 15.21 | 458 | 216 | 0.22 / 87.38 | 2 | 13 |
2 | 3 | 781.68 | -11 | 15.58 | 0 | 0 | 0.00 / 87.38 | 2 | 13 |
3 | 3 | 1040.20 | 1 | 15.25 | 1744 | 27 | 0.24 / 87.41 | 2 | 22 |
4 | 7 | 2006.32 | 38 | 14.87 | 2850 | 1610 | 1.85 / 89.02 | 2 | 23 |
5 | 13 | 1532.32 | 18 | 14.95 | 2297 | 618 | 2.47 / 89.64 | 2 | 26 |
6 | 13 | 975.48 | 18 | 15.07 | 1612 | 437 | 2.91 / 90.08 | 2 | 28 |
7 | 13 | 381.88 | 18 | 15.22 | 845 | 231 | 3.14 / 90.31 | 2 | 29 |
8 | 13 | 49.08 | 18 | 15.30 | 385 | 106 | 3.25 / 90.41 | 3 | 28 |
9 | 8 | -0.24 | 165 | 15.26 | 313 | 788 | 4.03 / 91.20 | 3 | 26 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 28 | 15.22 | 463 | 197 | 0.20 / 83.23 | 2 | 13 |
2 | 3 | 888.56 | -6 | 15.59 | 0 | 0 | 0.00 / 83.23 | 2 | 13 |
3 | 3 | 1229.04 | 6 | 15.13 | 1999 | 181 | 0.38 / 83.41 | 2 | 22 |
4 | 7 | 2008.36 | 38 | 14.88 | 2849 | 1611 | 1.99 / 85.03 | 2 | 23 |
5 | 13 | 1473.08 | 18 | 14.98 | 2228 | 601 | 2.59 / 85.63 | 2 | 26 |
6 | 13 | 892.00 | 18 | 15.10 | 1513 | 411 | 3.00 / 86.04 | 2 | 28 |
7 | 13 | 416.76 | 18 | 15.22 | 890 | 244 | 3.25 / 86.28 | 2 | 29 |
8 | 13 | 41.32 | 18 | 15.31 | 373 | 103 | 3.35 / 86.38 | 3 | 25 |
9 | 8 | 0.20 | 165 | 15.27 | 311 | 784 | 4.13 / 87.17 | 3 | 26 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 26 | 15.21 | 470 | 186 | 0.19 / 79.19 | 2 | 14 |
2 | 3 | 930.48 | -3 | 15.59 | 0 | 0 | 0.00 / 79.19 | 2 | 14 |
3 | 3 | 1101.56 | 3 | 15.21 | 1825 | 83 | 0.27 / 79.27 | 2 | 24 |
4 | 7 | 2006.96 | 38 | 14.88 | 2864 | 1619 | 1.89 / 80.89 | 2 | 23 |
5 | 13 | 1480.84 | 18 | 14.99 | 2255 | 608 | 2.50 / 81.50 | 2 | 26 |
6 | 13 | 943.24 | 18 | 15.09 | 1588 | 431 | 2.93 / 81.93 | 2 | 28 |
7 | 13 | 309.40 | 18 | 15.26 | 749 | 206 | 3.13 / 82.14 | 2 | 29 |
8 | 13 | 43.40 | 18 | 15.32 | 382 | 105 | 3.24 / 82.24 | 3 | 26 |
9 | 8 | 0.00 | 165 | 15.28 | 315 | 794 | 4.03 / 83.04 | 3 | 31 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 25 | 15.20 | 447 | 170 | 0.17 / 75.07 | 2 | 14 |
2 | 3 | 957.68 | -2 | 15.58 | 0 | 0 | 0.00 / 75.07 | 2 | 14 |
3 | 3 | 1084.80 | 2 | 15.21 | 1786 | 54 | 0.22 / 75.12 | 2 | 24 |
4 | 7 | 2009.20 | 38 | 14.89 | 2849 | 1612 | 1.84 / 76.73 | 2 | 23 |
5 | 13 | 1470.24 | 18 | 14.99 | 2223 | 600 | 2.44 / 77.33 | 2 | 26 |
6 | 13 | 946.44 | 18 | 15.08 | 1579 | 429 | 2.86 / 77.76 | 2 | 28 |
7 | 13 | 406.20 | 18 | 15.22 | 875 | 240 | 3.10 / 78.00 | 2 | 29 |
8 | 13 | 68.68 | 18 | 15.30 | 413 | 114 | 3.22 / 78.12 | 2 | 28 |
9 | 13 | 17.92 | 18 | 15.32 | 344 | 95 | 3.31 / 78.21 | 3 | 28 |
10 | 8 | 0.08 | 165 | 15.27 | 314 | 791 | 4.10 / 79.00 | 2 | 33 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 30 | 15.21 | 451 | 206 | 0.21 / 70.96 | 3 | 15 |
2 | 3 | 785.96 | -11 | 15.59 | 0 | 0 | 0.00 / 70.96 | 3 | 15 |
3 | 7 | 2010.00 | 38 | 14.88 | 2847 | 1610 | 1.82 / 72.57 | 2 | 23 |
4 | 13 | 1481.28 | 18 | 14.97 | 2237 | 603 | 2.42 / 73.17 | 2 | 26 |
5 | 13 | 1038.72 | 18 | 15.06 | 1698 | 460 | 2.88 / 73.63 | 2 | 28 |
6 | 13 | 423.88 | 18 | 15.22 | 902 | 247 | 3.13 / 73.88 | 2 | 29 |
7 | 13 | 81.76 | 18 | 15.31 | 440 | 121 | 3.25 / 74.00 | 3 | 29 |
8 | 13 | 21.56 | 18 | 15.31 | 352 | 97 | 3.34 / 74.10 | 3 | 25 |
9 | 8 | 0.36 | 165 | 15.26 | 317 | 798 | 4.14 / 74.90 | 3 | 35 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 29 | 15.21 | 466 | 206 | 0.21 / 66.68 | 3 | 14 |
2 | 3 | 841.16 | -8 | 15.60 | 0 | 0 | 0.00 / 66.68 | 3 | 14 |
3 | 3 | 1173.40 | 5 | 15.17 | 1924 | 146 | 0.35 / 66.83 | 2 | 23 |
4 | 7 | 2004.20 | 38 | 14.89 | 2858 | 1617 | 1.97 / 68.45 | 2 | 23 |
5 | 13 | 1513.80 | 18 | 14.99 | 2286 | 617 | 2.59 / 69.06 | 2 | 26 |
6 | 13 | 960.68 | 18 | 15.10 | 1602 | 435 | 3.02 / 69.50 | 2 | 28 |
7 | 13 | 407.88 | 18 | 15.24 | 884 | 242 | 3.26 / 69.74 | 2 | 29 |
8 | 13 | 72.12 | 18 | 15.32 | 425 | 117 | 3.38 / 69.86 | 2 | 28 |
9 | 13 | 17.28 | 18 | 15.33 | 344 | 95 | 3.48 / 69.95 | 3 | 29 |
10 | 8 | -0.20 | 165 | 15.28 | 318 | 802 | 4.28 / 70.76 | 3 | 27 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.68 | 27 | 15.21 | 477 | 196 | 0.20 / 62.41 | 2 | 13 |
2 | 3 | 924.48 | -4 | 15.60 | 0 | 0 | 0.00 / 62.41 | 2 | 13 |
3 | 3 | 1158.68 | 4 | 15.19 | 1899 | 115 | 0.31 / 62.53 | 2 | 23 |
4 | 7 | 2005.40 | 38 | 14.90 | 2862 | 1620 | 1.93 / 64.15 | 2 | 23 |
5 | 13 | 1517.08 | 18 | 15.00 | 2290 | 618 | 2.55 / 64.77 | 2 | 26 |
6 | 13 | 965.00 | 18 | 15.10 | 1610 | 438 | 2.99 / 65.21 | 2 | 28 |
7 | 13 | 415.72 | 18 | 15.24 | 902 | 247 | 3.24 / 65.45 | 2 | 29 |
8 | 13 | 84.32 | 18 | 15.32 | 446 | 123 | 3.36 / 65.58 | 3 | 29 |
9 | 13 | 20.96 | 18 | 15.33 | 354 | 98 | 3.46 / 65.67 | 3 | 27 |
10 | 8 | -0.12 | 165 | 15.28 | 319 | 804 | 4.26 / 66.48 | 3 | 32 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 26 | 15.22 | 472 | 187 | 0.19 / 58.22 | 2 | 13 |
2 | 3 | 950.56 | -2 | 15.61 | 0 | 0 | 0.00 / 58.22 | 2 | 13 |
3 | 3 | 1070.52 | 2 | 15.25 | 1801 | 55 | 0.24 / 58.28 | 2 | 22 |
4 | 7 | 2008.92 | 38 | 14.92 | 2867 | 1625 | 1.87 / 59.90 | 2 | 23 |
5 | 13 | 1507.12 | 18 | 15.00 | 2286 | 617 | 2.48 / 60.52 | 2 | 26 |
6 | 13 | 951.64 | 18 | 15.12 | 1596 | 434 | 2.92 / 60.96 | 2 | 28 |
7 | 13 | 407.40 | 18 | 15.25 | 886 | 243 | 3.16 / 61.20 | 2 | 29 |
8 | 13 | 77.28 | 18 | 15.34 | 436 | 120 | 3.28 / 61.32 | 3 | 29 |
9 | 13 | 19.36 | 18 | 15.34 | 354 | 98 | 3.38 / 61.42 | 3 | 29 |
10 | 8 | -0.20 | 165 | 15.29 | 318 | 802 | 4.18 / 62.22 | 3 | 29 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 25 | 15.23 | 453 | 172 | 0.17 / 54.01 | 3 | 13 |
2 | 3 | 961.00 | -2 | 15.60 | 0 | 0 | 0.00 / 54.01 | 3 | 13 |
3 | 3 | 1078.04 | 2 | 15.25 | 1806 | 55 | 0.23 / 54.07 | 2 | 24 |
4 | 7 | 2007.60 | 38 | 14.90 | 2868 | 1624 | 1.85 / 55.69 | 2 | 23 |
5 | 13 | 1579.00 | 18 | 14.98 | 2368 | 639 | 2.49 / 56.33 | 2 | 26 |
6 | 13 | 967.84 | 18 | 15.11 | 1606 | 437 | 2.93 / 56.77 | 2 | 28 |
7 | 13 | 425.48 | 18 | 15.24 | 910 | 250 | 3.18 / 57.02 | 2 | 29 |
8 | 13 | 91.96 | 18 | 15.32 | 453 | 125 | 3.30 / 57.14 | 3 | 29 |
9 | 13 | 21.60 | 18 | 15.32 | 352 | 97 | 3.40 / 57.24 | 3 | 29 |
10 | 8 | -0.04 | 165 | 15.28 | 316 | 797 | 4.20 / 58.04 | 3 | 30 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 24 | 15.25 | 452 | 165 | 0.17 / 49.81 | 3 | 14 |
2 | 3 | 985.72 | -1 | 15.61 | 0 | 0 | 0.00 / 49.81 | 3 | 14 |
3 | 3 | 1053.80 | 2 | 15.26 | 1768 | 54 | 0.22 / 49.86 | 2 | 24 |
4 | 7 | 2011.32 | 38 | 14.92 | 2863 | 1623 | 1.84 / 51.49 | 2 | 23 |
5 | 13 | 1520.04 | 18 | 15.01 | 2287 | 618 | 2.46 / 52.11 | 2 | 26 |
6 | 13 | 1027.56 | 18 | 15.10 | 1684 | 458 | 2.92 / 52.56 | 2 | 28 |
7 | 13 | 418.40 | 18 | 15.26 | 903 | 248 | 3.17 / 52.81 | 2 | 29 |
8 | 13 | 87.56 | 18 | 15.34 | 452 | 125 | 3.29 / 52.94 | 3 | 27 |
9 | 13 | 20.60 | 18 | 15.34 | 355 | 98 | 3.39 / 53.03 | 3 | 25 |
10 | 8 | 0.04 | 165 | 15.29 | 320 | 807 | 4.20 / 53.84 | 3 | 29 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 24 | 15.23 | 461 | 169 | 0.17 / 45.80 | 2 | 13 |
2 | 7 | 2009.88 | 38 | 14.93 | 2867 | 1627 | 1.80 / 47.42 | 2 | 23 |
3 | 13 | 1483.52 | 18 | 15.02 | 2247 | 607 | 2.40 / 48.03 | 2 | 26 |
4 | 13 | 986.92 | 18 | 15.12 | 1632 | 444 | 2.85 / 48.47 | 2 | 28 |
5 | 13 | 386.08 | 18 | 15.27 | 854 | 235 | 3.08 / 48.71 | 2 | 29 |
6 | 13 | 106.24 | 18 | 15.33 | 475 | 131 | 3.21 / 48.84 | 3 | 28 |
7 | 8 | -0.20 | 165 | 15.31 | 319 | 806 | 4.02 / 49.65 | 4 | 30 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 24 | 15.24 | 479 | 175 | 0.18 / 41.74 | 2 | 15 |
2 | 3 | 1033.52 | 1 | 15.27 | 1738 | 27 | 0.20 / 41.77 | 2 | 23 |
3 | 7 | 2004.60 | 38 | 14.93 | 2854 | 1619 | 1.82 / 43.39 | 2 | 23 |
4 | 13 | 1507.08 | 18 | 15.02 | 2276 | 615 | 2.44 / 44.00 | 2 | 26 |
5 | 13 | 1009.04 | 18 | 15.12 | 1659 | 452 | 2.89 / 44.45 | 2 | 28 |
6 | 13 | 403.28 | 18 | 15.27 | 882 | 242 | 3.13 / 44.69 | 2 | 29 |
7 | 13 | 90.16 | 18 | 15.33 | 453 | 125 | 3.26 / 44.82 | 2 | 28 |
8 | 8 | -0.04 | 165 | 15.29 | 320 | 807 | 4.06 / 45.63 | 3 | 30 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 23 | 15.26 | 458 | 161 | 0.16 / 37.70 | 3 | 15 |
2 | 7 | 2003.36 | 38 | 14.93 | 2857 | 1621 | 1.78 / 39.32 | 2 | 23 |
3 | 13 | 1572.40 | 18 | 15.01 | 2357 | 637 | 2.42 / 39.96 | 2 | 26 |
4 | 13 | 868.64 | 18 | 15.15 | 1489 | 406 | 2.82 / 40.37 | 2 | 28 |
5 | 13 | 445.40 | 18 | 15.25 | 937 | 257 | 3.08 / 40.62 | 2 | 29 |
6 | 13 | 108.00 | 18 | 15.34 | 480 | 133 | 3.21 / 40.76 | 3 | 28 |
7 | 8 | -0.24 | 165 | 15.31 | 320 | 808 | 4.02 / 41.56 | 2 | 28 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.24 | 19 | 15.26 | 481 | 139 | 0.14 / 33.60 | 2 | 15 |
2 | 10 | 1061.08 | 3 | 15.22 | 1765 | 81 | 0.22 / 33.68 | 2 | 21 |
3 | 3 | 1078.76 | 2 | 15.22 | 1804 | 55 | 0.27 / 33.74 | 2 | 23 |
4 | 7 | 2005.52 | 38 | 14.94 | 2856 | 1621 | 1.90 / 35.36 | 2 | 23 |
5 | 13 | 1409.28 | 18 | 15.05 | 2173 | 589 | 2.49 / 35.95 | 2 | 26 |
6 | 13 | 845.48 | 18 | 15.16 | 1464 | 399 | 2.88 / 36.35 | 2 | 28 |
7 | 13 | 419.52 | 18 | 15.25 | 913 | 251 | 3.14 / 36.60 | 2 | 29 |
8 | 13 | 98.44 | 18 | 15.34 | 465 | 128 | 3.26 / 36.73 | 2 | 28 |
9 | 8 | 0.08 | 165 | 15.31 | 322 | 813 | 4.08 / 37.54 | 3 | 29 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 29 | 15.25 | 457 | 202 | 0.20 / 29.15 | 2 | 16 |
2 | 3 | 776.44 | -4 | 15.66 | 0 | 0 | 0.00 / 29.15 | 2 | 16 |
3 | 3 | 858.64 | -3 | 15.68 | 0 | 0 | 0.00 / 29.15 | 2 | 16 |
4 | 7 | 2004.64 | 74 | 14.82 | 2840 | 3115 | 3.32 / 32.26 | 2 | 24 |
5 | 13 | 476.04 | 18 | 15.26 | 969 | 266 | 3.58 / 32.53 | 2 | 29 |
6 | 13 | 131.16 | 18 | 15.34 | 503 | 139 | 3.72 / 32.67 | 2 | 28 |
7 | 8 | 0.24 | 165 | 15.32 | 315 | 796 | 4.52 / 33.46 | 3 | 31 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 23 | 15.22 | 472 | 165 | 0.17 / 24.84 | 3 | 15 |
2 | 7 | 1775.84 | 74 | 14.91 | 2572 | 2838 | 3.00 / 27.67 | 2 | 24 |
3 | 13 | 393.40 | 18 | 15.28 | 868 | 239 | 3.24 / 27.91 | 2 | 29 |
4 | 13 | 118.08 | 18 | 15.35 | 489 | 135 | 3.38 / 28.05 | 2 | 28 |
5 | 13 | 17.36 | 18 | 15.35 | 348 | 96 | 3.47 / 28.14 | 3 | 26 |
6 | 8 | 0.24 | 165 | 15.31 | 318 | 803 | 4.28 / 28.95 | 2 | 26 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 23 | 15.25 | 457 | 160 | 0.16 / 20.29 | 2 | 16 |
2 | 7 | 1796.16 | 74 | 14.88 | 2591 | 2853 | 3.01 / 23.15 | 2 | 24 |
3 | 13 | 371.76 | 18 | 15.27 | 834 | 229 | 3.24 / 23.38 | 2 | 28 |
4 | 13 | 101.24 | 18 | 15.33 | 462 | 127 | 3.37 / 23.50 | 3 | 28 |
5 | 8 | 0.24 | 165 | 15.30 | 319 | 805 | 4.18 / 24.31 | 3 | 27 |
6 | 14 | 0.24 | 75 | 15.26 | 315 | 361 | 4.54 / 24.67 | 5 | 33 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 23 | 15.26 | 477 | 167 | 0.17 / 16.10 | 2 | 16 |
2 | 7 | 1802.32 | 74 | 14.90 | 2597 | 2863 | 3.03 / 18.97 | 2 | 24 |
3 | 13 | 386.60 | 18 | 15.28 | 849 | 234 | 3.26 / 19.20 | 2 | 28 |
4 | 13 | 115.48 | 18 | 15.34 | 479 | 132 | 3.40 / 19.33 | 3 | 28 |
5 | 8 | 0.04 | 165 | 15.31 | 317 | 801 | 4.20 / 20.13 | 3 | 32 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 22 | 15.27 | 454 | 153 | 0.15 / 12.22 | 2 | 16 |
2 | 10 | 1000.52 | 2 | 15.25 | 1680 | 51 | 0.20 / 12.27 | 2 | 22 |
3 | 3 | 968.64 | -1 | 15.66 | 0 | 0 | 0.05 / 12.27 | 2 | 22 |
4 | 3 | 1025.16 | 1 | 15.33 | 1738 | 27 | 0.23 / 12.30 | 2 | 25 |
5 | 7 | 1508.00 | 74 | 15.01 | 2246 | 2495 | 2.73 / 14.79 | 2 | 24 |
6 | 13 | 326.12 | 18 | 15.31 | 769 | 212 | 2.94 / 15.00 | 2 | 28 |
7 | 13 | 98.32 | 18 | 15.36 | 460 | 127 | 3.06 / 15.13 | 2 | 28 |
8 | 8 | -0.04 | 165 | 15.32 | 319 | 806 | 3.87 / 15.94 | 4 | 32 |
Average= | 3.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 16 | 15.28 | 449 | 110 | 0.11 / 8.22 | 2 | 16 |
2 | 10 | 1015.36 | 4 | 15.24 | 1687 | 103 | 0.21 / 8.32 | 2 | 20 |
3 | 10 | 1048.20 | 2 | 15.25 | 1743 | 53 | 0.27 / 8.38 | 2 | 20 |
4 | 3 | 1032.92 | 1 | 15.31 | 1724 | 26 | 0.29 / 8.40 | 2 | 25 |
5 | 7 | 1509.12 | 74 | 15.01 | 2247 | 2496 | 2.79 / 10.90 | 2 | 24 |
6 | 13 | 420.24 | 18 | 15.28 | 890 | 245 | 3.03 / 11.14 | 2 | 29 |
7 | 13 | 81.76 | 18 | 15.36 | 438 | 121 | 3.15 / 11.27 | 3 | 28 |
8 | 8 | -0.28 | 165 | 15.32 | 317 | 801 | 3.96 / 12.07 | 3 | 29 |
Average= | 3.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 32 | 15.32 | 470 | 230 | 0.23 / 4.57 | 2 | 17 |
2 | 3 | 705.68 | -6 | 15.68 | 0 | 0 | 0.00 / 4.57 | 2 | 17 |
3 | 3 | 779.24 | -4 | 15.70 | 0 | 0 | 0.00 / 4.57 | 2 | 17 |
4 | 7 | 1521.28 | 74 | 15.02 | 2240 | 2490 | 2.72 / 7.06 | 2 | 23 |
5 | 13 | 187.20 | 18 | 15.35 | 568 | 157 | 2.88 / 7.22 | 2 | 26 |
6 | 13 | 60.32 | 18 | 15.37 | 399 | 110 | 2.99 / 7.33 | 2 | 27 |
7 | 8 | 0.12 | 165 | 15.33 | 310 | 784 | 3.77 / 8.11 | 2 | 33 |
Average= | 2.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 27 | 15.49 | 433 | 181 | 0.18 / 1.77 | 3 | 10 |
2 | 3 | 917.88 | -2 | 15.70 | 0 | 0 | 0.00 / 1.77 | 3 | 10 |
3 | 3 | 967.16 | -1 | 15.71 | 0 | 0 | 0.00 / 1.77 | 3 | 10 |
4 | 7 | 992.64 | 74 | 15.21 | 1589 | 1788 | 1.97 / 3.56 | 2 | 27 |
5 | 8 | -0.04 | 165 | 15.40 | 308 | 783 | 2.75 / 4.34 | 4 | 33 |
Average= | 2.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 57.24 | 26 | 15.66 | 358 | 146 | 0.15 / 0.15 | 3 | 10 |
2 | 7 | 75.68 | 74 | 15.63 | 380 | 440 | 0.59 / 0.59 | 3 | 14 |
3 | 8 | 0.20 | 240 | 15.58 | 268 | 1002 | 1.59 / 1.59 | 3 | 25 |
Average= | 1.59 (KJ/cycle) |