SIO Argo Site:
Pump Diagnostics Page   



Serial= 3267 WMO= 5907113

Return

←PreviousNext→

Cycle 20 GMT 11/12/2024 16:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 31 15.16 440 207 0.21 / 74.09 2 2
2 7 2011.32 38 14.86 2685 1516 1.72 / 75.61 2 6
3 13 1234.40 18 14.94 1814 488 2.21 / 76.09 2 12
4 13 864.96 18 14.99 1402 378 2.59 / 76.47 2 10
5 13 256.36 18 15.14 658 179 2.77 / 76.65 2 11
6 13 139.08 18 15.16 503 137 2.91 / 76.79 2 12
7 13 111.52 18 15.17 465 127 3.03 / 76.92 2 7
8 13 35.72 18 15.19 351 96 3.13 / 77.01 2 9
9 8 0.20 165 15.17 295 738 3.87 / 77.75 2 12
Average= 3.70
(KJ/cycle)

Cycle 19 GMT 1/12/2024 20:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 31 15.16 431 203 0.20 / 70.17 2 2
2 7 2002.48 38 14.88 2679 1515 1.72 / 71.68 2 6
3 13 1386.40 18 14.94 2004 539 2.26 / 72.22 2 8
4 13 898.56 18 15.01 1443 390 2.65 / 72.61 2 11
5 13 218.96 18 15.16 615 168 2.81 / 72.78 2 11
6 13 140.52 18 15.18 516 141 2.95 / 72.92 2 12
7 13 116.12 18 15.18 477 130 3.09 / 73.05 2 9
8 13 16.76 18 15.22 327 90 3.17 / 73.14 2 7
9 8 -0.04 165 15.18 296 741 3.92 / 73.88 2 12
Average= 3.69
(KJ/cycle)

Cycle 18 GMT 22/11/2024 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 31 15.16 434 204 0.20 / 66.29 2 2
2 7 2003.28 38 14.88 2668 1509 1.71 / 67.79 2 6
3 13 1398.00 18 14.93 2020 543 2.26 / 68.34 2 9
4 13 869.08 18 15.01 1410 381 2.64 / 68.72 2 11
5 13 213.92 18 15.16 610 166 2.80 / 68.88 2 8
6 13 139.48 18 15.19 509 139 2.94 / 69.02 2 8
7 13 115.76 18 15.18 472 129 3.07 / 69.15 2 8
8 13 35.36 18 15.21 350 96 3.17 / 69.25 2 13
9 8 0.00 165 15.19 287 719 3.89 / 69.97 2 21
Average= 3.68
(KJ/cycle)

Cycle 17 GMT 12/11/2024 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 31 15.17 434 204 0.20 / 62.54 2 2
2 7 2003.48 38 14.89 2659 1505 1.71 / 64.04 2 6
3 13 1346.72 18 14.95 1946 524 2.23 / 64.56 2 8
4 13 814.96 18 15.03 1335 361 2.59 / 64.93 2 12
5 13 224.64 18 15.16 614 168 2.76 / 65.09 2 8
6 13 139.68 18 15.18 507 139 2.90 / 65.23 2 7
7 13 111.92 18 15.18 465 127 3.03 / 65.36 2 13
8 8 -0.04 165 15.20 288 722 3.75 / 66.08 2 16
Average= 3.67
(KJ/cycle)

Cycle 16 GMT 2/11/2024 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 31 15.16 433 203 0.20 / 58.81 2 2
2 7 2004.52 38 14.88 2657 1502 1.71 / 60.31 2 5
3 13 1341.16 18 14.93 1929 518 2.22 / 60.83 2 7
4 13 732.52 18 15.04 1237 335 2.56 / 61.16 2 10
5 13 257.04 18 15.14 663 181 2.74 / 61.34 2 9
6 13 147.72 18 15.17 515 141 2.88 / 61.48 2 10
7 13 118.96 18 15.17 476 130 3.01 / 61.61 2 11
8 8 0.40 165 15.19 287 719 3.73 / 62.33 2 16
Average= 3.67
(KJ/cycle)

Cycle 15 GMT 23/10/2024 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 31 15.16 431 203 0.20 / 54.99 2 2
2 7 2007.52 38 14.87 2663 1505 1.71 / 56.49 2 6
3 13 1212.32 18 14.96 1796 484 2.19 / 56.98 2 10
4 13 801.84 18 15.01 1321 357 2.55 / 57.33 2 11
5 13 252.12 18 15.14 654 178 2.73 / 57.51 2 11
6 13 136.36 18 15.18 500 137 2.86 / 57.65 2 12
7 13 111.56 18 15.18 459 125 2.99 / 57.77 2 8
8 13 32.64 18 15.21 346 95 3.08 / 57.87 2 10
9 8 -0.04 165 15.19 293 734 3.82 / 58.60 2 17
Average= 3.66
(KJ/cycle)

Cycle 14 GMT 13/10/2024 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 30 15.18 427 194 0.19 / 51.12 2 2
2 3 1017.80 1 15.23 1606 24 0.22 / 51.15 2 4
3 7 2008.72 38 14.89 2664 1507 1.73 / 52.65 2 6
4 13 1314.92 18 14.95 1918 516 2.24 / 53.17 2 8
5 13 818.32 18 15.02 1340 362 2.60 / 53.53 2 9
6 13 240.76 18 15.17 634 173 2.78 / 53.71 2 9
7 13 146.12 18 15.18 518 142 2.92 / 53.85 2 9
8 13 114.96 18 15.19 465 127 3.05 / 53.97 2 11
9 13 17.20 18 15.22 319 87 3.13 / 54.06 2 13
10 8 0.28 165 15.19 289 724 3.86 / 54.79 2 17
Average= 3.65
(KJ/cycle)

Cycle 13 GMT 3/10/2024 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 30 15.18 424 193 0.19 / 47.37 2 2
2 7 2010.52 38 14.89 2672 1512 1.70 / 48.88 2 7
3 13 1309.28 18 14.97 1897 511 2.22 / 49.39 2 7
4 13 889.88 18 15.02 1405 380 2.60 / 49.77 2 10
5 13 243.32 18 15.17 624 170 2.77 / 49.94 2 10
6 13 144.84 18 15.19 504 138 2.90 / 50.08 2 10
7 13 107.88 18 15.19 457 125 3.03 / 50.20 2 11
8 8 0.20 165 15.21 288 723 3.75 / 50.93 2 21
Average= 3.64
(KJ/cycle)

Cycle 12 GMT 24/ 9/2024 3:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 30 15.18 433 197 0.20 / 43.55 2 2
2 7 2003.68 38 14.90 2658 1505 1.70 / 45.05 2 8
3 13 1344.44 18 14.97 1923 518 2.22 / 45.57 2 9
4 13 860.72 18 15.02 1378 373 2.59 / 45.94 2 11
5 13 227.20 18 15.19 608 166 2.76 / 46.11 2 9
6 13 139.00 18 15.20 503 138 2.90 / 46.25 2 11
7 13 105.56 18 15.20 453 124 3.02 / 46.37 2 10
8 13 13.92 18 15.25 312 86 3.11 / 46.46 2 16
9 8 0.12 165 15.20 287 720 3.83 / 47.18 2 12
Average= 3.63
(KJ/cycle)

Cycle 11 GMT 14/ 9/2024 8: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 30 15.19 428 195 0.20 / 39.70 2 2
2 7 2007.96 38 14.91 2666 1511 1.71 / 41.21 2 5
3 13 1381.92 18 14.96 1974 532 2.24 / 41.74 2 9
4 13 801.88 18 15.05 1316 357 2.59 / 42.09 2 10
5 13 207.40 18 15.19 589 161 2.75 / 42.25 2 11
6 13 132.16 18 15.20 493 135 2.89 / 42.39 2 8
7 13 101.76 18 15.21 451 123 3.01 / 42.51 2 12
8 13 27.16 18 15.23 340 93 3.11 / 42.61 2 5
9 8 -0.08 165 15.21 296 743 3.85 / 43.35 2 16
Average= 3.61
(KJ/cycle)

Cycle 10 GMT 4/ 9/2024 12:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 30 15.20 428 195 0.20 / 35.95 2 2
2 7 2004.64 38 14.91 2663 1509 1.70 / 37.45 2 9
3 13 1356.36 18 14.97 1953 526 2.23 / 37.98 2 6
4 13 860.16 18 15.03 1379 373 2.60 / 38.35 2 10
5 13 202.08 18 15.19 579 158 2.76 / 38.51 2 10
6 13 130.64 18 15.22 487 133 2.90 / 38.65 2 9
7 13 99.56 18 15.21 442 121 3.02 / 38.77 2 10
8 8 0.20 165 15.22 292 733 3.75 / 39.50 2 18
Average= 3.59
(KJ/cycle)

Cycle 9 GMT 25/ 8/2024 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 29 15.20 435 192 0.19 / 31.47 2 2
2 3 1032.52 1 15.22 1637 25 0.22 / 31.49 2 7
3 3 1019.32 1 15.26 1608 25 0.24 / 31.52 2 8
4 7 2006.36 74 14.80 2639 2890 3.13 / 34.41 2 10
5 13 456.32 18 15.16 874 238 3.37 / 34.65 2 11
6 13 168.92 18 15.22 520 142 3.51 / 34.79 2 11
7 13 89.20 18 15.24 408 112 3.62 / 34.90 2 9
8 13 51.56 18 15.26 345 95 3.72 / 35.00 2 15
9 8 0.20 165 15.23 300 754 4.47 / 35.75 2 9
Average= 3.58
(KJ/cycle)

Cycle 8 GMT 15/ 8/2024 19:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 30 15.20 439 200 0.20 / 26.97 2 2
2 3 969.08 -1 15.53 0 0 0.00 / 26.97 2 2
3 3 1028.52 1 15.25 1626 25 0.22 / 27.00 2 8
4 7 2003.72 74 14.80 2651 2903 3.13 / 29.90 2 9
5 13 482.00 18 15.13 934 254 3.38 / 30.16 2 11
6 13 135.56 18 15.22 505 138 3.52 / 30.30 2 10
7 13 99.96 18 15.23 453 124 3.65 / 30.42 2 10
8 13 34.00 18 15.25 364 100 3.75 / 30.52 2 13
9 8 -0.36 165 15.22 302 758 4.50 / 31.28 2 22
Average= 3.48
(KJ/cycle)

Cycle 7 GMT 5/ 8/2024 22:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 29 15.22 428 189 0.19 / 23.07 2 2
2 7 1518.40 74 14.95 2118 2343 2.53 / 25.41 2 9
3 13 427.12 18 15.17 864 236 2.77 / 25.65 2 11
4 13 131.72 18 15.24 498 137 2.90 / 25.78 2 10
5 13 90.92 18 15.24 447 123 3.03 / 25.91 2 12
6 13 22.04 18 15.26 350 96 3.12 / 26.00 2 13
7 8 0.20 165 15.23 307 771 3.89 / 26.77 2 18
Average= 3.35
(KJ/cycle)

Cycle 6 GMT 4/ 8/2024 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 29 15.23 427 189 0.19 / 19.24 2 2
2 7 1515.36 74 14.97 2108 2335 2.52 / 21.57 2 11
3 13 325.28 18 15.20 737 202 2.73 / 21.77 2 11
4 13 133.04 18 15.24 496 136 2.86 / 21.91 2 10
5 13 95.36 18 15.25 443 122 2.98 / 22.03 2 11
6 13 22.96 18 15.27 343 94 3.08 / 22.13 2 13
7 8 0.24 165 15.24 300 754 3.83 / 22.88 2 24
Average= 3.27
(KJ/cycle)

Cycle 5 GMT 3/ 8/2024 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 29 15.21 438 193 0.19 / 15.49 2 2
2 7 1513.28 74 14.96 2113 2339 2.53 / 17.83 2 9
3 13 301.68 18 15.21 710 194 2.73 / 18.03 2 11
4 13 140.16 18 15.25 505 139 2.87 / 18.16 2 10
5 13 99.08 18 15.25 451 124 2.99 / 18.29 2 11
6 8 0.20 165 15.24 302 759 3.75 / 19.05 2 13
Average= 3.17
(KJ/cycle)

Cycle 4 GMT 2/ 8/2024 23:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 29 15.21 437 193 0.19 / 11.62 2 2
2 7 1526.28 75 14.96 2118 2376 2.57 / 13.99 2 9
3 13 277.04 18 15.22 678 186 2.75 / 14.18 2 9
4 13 132.64 18 15.24 502 138 2.89 / 14.32 2 9
5 13 91.28 18 15.25 441 121 3.01 / 14.44 2 8
6 13 23.68 18 15.26 346 95 3.11 / 14.53 2 9
7 8 0.12 165 15.24 305 767 3.88 / 15.30 2 14
Average= 3.06
(KJ/cycle)

Cycle 3 GMT 1/ 8/2024 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 29 15.24 393 174 0.17 / 7.90 2 2
2 7 1526.04 74 14.97 2101 2327 2.50 / 10.23 2 9
3 13 234.28 18 15.23 610 167 2.67 / 10.40 2 10
4 13 139.88 18 15.25 505 139 2.81 / 10.54 2 9
5 13 97.72 18 15.25 451 124 2.93 / 10.66 2 10
6 8 0.16 165 15.26 303 763 3.69 / 11.42 2 17
Average= 2.86
(KJ/cycle)

Cycle 2 GMT 31/ 7/2024 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 32 15.29 381 186 0.19 / 4.33 2 2
2 3 847.28 -3 15.56 0 0 0.00 / 4.33 2 2
3 7 1510.20 75 14.98 2069 2325 2.51 / 6.65 2 10
4 13 297.48 18 15.23 677 186 2.70 / 6.84 2 11
5 13 139.96 18 15.26 473 130 2.83 / 6.97 2 10
6 13 65.68 18 15.28 361 99 2.93 / 7.07 2 13
7 8 0.16 165 15.27 262 660 3.59 / 7.73 2 30
Average= 2.58
(KJ/cycle)

Cycle 1 GMT 31/ 7/2024 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 27 15.46 366 153 0.15 / 1.61 3 3
2 3 1016.36 1 15.31 1614 25 0.18 / 1.63 2 7
3 7 997.40 74 15.15 1490 1670 1.85 / 3.30 2 13
4 13 77.76 18 15.35 378 104 1.95 / 3.41 2 12
5 13 23.12 18 15.35 297 82 2.03 / 3.49 2 17
6 8 0.08 165 15.33 259 655 2.69 / 4.14 2 14
Average= 2.07
(KJ/cycle)

Cycle 0 GMT 30/ 7/2024 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 88.12 27 15.62 347 146 0.15 / 0.15 3 15
2 7 107.20 74 15.60 366 423 0.57 / 0.57 3 3
3 13 65.56 18 15.58 300 84 0.65 / 0.65 3 5
4 8 0.12 240 15.53 215 801 1.45 / 1.45 3 10
Average= 1.45
(KJ/cycle)