SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 31 | 15.23 | 426 | 201 | 0.20 / 58.80 | 2 | 2 |
2 | 7 | 2005.12 | 38 | 14.97 | 2710 | 1542 | 1.74 / 60.34 | 2 | 4 |
3 | 13 | 1416.72 | 18 | 15.04 | 2032 | 550 | 2.29 / 60.89 | 2 | 5 |
4 | 13 | 924.48 | 18 | 15.11 | 1448 | 394 | 2.69 / 61.29 | 2 | 7 |
5 | 13 | 244.64 | 18 | 15.26 | 613 | 168 | 2.86 / 61.45 | 2 | 6 |
6 | 8 | 0.24 | 165 | 15.28 | 289 | 729 | 3.58 / 62.18 | 2 | 16 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 31 | 15.24 | 447 | 211 | 0.21 / 55.27 | 2 | 3 |
2 | 7 | 2011.68 | 38 | 14.97 | 2730 | 1553 | 1.76 / 56.82 | 2 | 4 |
3 | 13 | 1358.64 | 18 | 15.04 | 1964 | 532 | 2.30 / 57.35 | 2 | 6 |
4 | 13 | 877.16 | 18 | 15.13 | 1399 | 381 | 2.68 / 57.73 | 2 | 6 |
5 | 13 | 206.04 | 18 | 15.27 | 559 | 154 | 2.83 / 57.89 | 2 | 6 |
6 | 8 | 0.00 | 165 | 15.28 | 282 | 711 | 3.54 / 58.60 | 2 | 17 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 31 | 15.23 | 432 | 204 | 0.20 / 51.73 | 2 | 2 |
2 | 7 | 2011.92 | 38 | 14.98 | 2719 | 1548 | 1.75 / 53.28 | 2 | 4 |
3 | 13 | 1320.84 | 18 | 15.05 | 1926 | 522 | 2.27 / 53.80 | 2 | 5 |
4 | 13 | 885.08 | 18 | 15.12 | 1395 | 380 | 2.65 / 54.18 | 2 | 8 |
5 | 13 | 238.64 | 18 | 15.29 | 606 | 167 | 2.82 / 54.34 | 2 | 6 |
6 | 8 | -0.48 | 165 | 15.29 | 283 | 714 | 3.53 / 55.06 | 2 | 14 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 31 | 15.24 | 430 | 203 | 0.20 / 48.12 | 2 | 3 |
2 | 7 | 2006.04 | 38 | 14.97 | 2707 | 1540 | 1.74 / 49.66 | 2 | 3 |
3 | 13 | 1455.00 | 18 | 15.04 | 2083 | 564 | 2.31 / 50.23 | 2 | 5 |
4 | 13 | 873.88 | 18 | 15.13 | 1391 | 379 | 2.69 / 50.61 | 2 | 5 |
5 | 13 | 340.96 | 18 | 15.24 | 731 | 201 | 2.89 / 50.81 | 2 | 7 |
6 | 8 | 0.24 | 165 | 15.27 | 285 | 718 | 3.60 / 51.52 | 2 | 17 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 31 | 15.25 | 434 | 205 | 0.21 / 44.56 | 2 | 2 |
2 | 3 | 983.28 | -1 | 15.55 | 1 | 0 | 0.00 / 44.56 | 2 | 2 |
3 | 7 | 2006.64 | 38 | 15.00 | 2714 | 1547 | 1.75 / 46.10 | 2 | 3 |
4 | 13 | 1416.96 | 18 | 15.05 | 2032 | 550 | 2.30 / 46.66 | 2 | 5 |
5 | 13 | 882.00 | 18 | 15.14 | 1398 | 381 | 2.68 / 47.04 | 2 | 7 |
6 | 13 | 263.48 | 18 | 15.27 | 625 | 172 | 2.86 / 47.21 | 2 | 6 |
7 | 8 | 0.24 | 165 | 15.29 | 282 | 711 | 3.57 / 47.92 | 2 | 18 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 30 | 15.26 | 436 | 200 | 0.20 / 40.98 | 2 | 2 |
2 | 10 | 1002.76 | 2 | 15.25 | 1584 | 48 | 0.25 / 41.03 | 2 | 2 |
3 | 3 | 969.44 | -1 | 15.55 | 1 | 0 | 0.05 / 41.03 | 2 | 2 |
4 | 7 | 2011.20 | 38 | 14.97 | 2714 | 1544 | 1.79 / 42.57 | 2 | 3 |
5 | 13 | 1361.76 | 18 | 15.04 | 1963 | 531 | 2.32 / 43.10 | 2 | 3 |
6 | 13 | 918.88 | 18 | 15.11 | 1441 | 392 | 2.72 / 43.50 | 2 | 6 |
7 | 13 | 194.44 | 18 | 15.27 | 539 | 148 | 2.86 / 43.64 | 2 | 5 |
8 | 8 | -0.08 | 165 | 15.29 | 281 | 709 | 3.57 / 44.35 | 2 | 15 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 30 | 15.26 | 426 | 195 | 0.20 / 37.47 | 2 | 3 |
2 | 7 | 2010.76 | 38 | 14.99 | 2719 | 1549 | 1.74 / 39.02 | 2 | 3 |
3 | 13 | 1400.88 | 18 | 15.04 | 2014 | 545 | 2.29 / 39.57 | 2 | 3 |
4 | 13 | 826.36 | 18 | 15.14 | 1332 | 363 | 2.65 / 39.93 | 2 | 6 |
5 | 13 | 173.40 | 18 | 15.30 | 510 | 140 | 2.79 / 40.07 | 2 | 6 |
6 | 8 | 0.00 | 165 | 15.29 | 281 | 709 | 3.50 / 40.78 | 2 | 17 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 29 | 15.26 | 421 | 186 | 0.19 / 33.91 | 2 | 2 |
2 | 10 | 1036.92 | 2 | 15.25 | 1622 | 49 | 0.24 / 33.96 | 2 | 2 |
3 | 7 | 2009.60 | 38 | 15.00 | 2716 | 1548 | 1.78 / 35.51 | 2 | 3 |
4 | 13 | 1358.44 | 18 | 15.07 | 1972 | 535 | 2.32 / 36.04 | 2 | 4 |
5 | 13 | 834.84 | 18 | 15.16 | 1332 | 363 | 2.68 / 36.41 | 2 | 5 |
6 | 13 | 240.00 | 18 | 15.28 | 597 | 164 | 2.85 / 36.57 | 2 | 6 |
7 | 8 | 0.20 | 165 | 15.30 | 280 | 707 | 3.55 / 37.28 | 2 | 15 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 28 | 15.27 | 418 | 179 | 0.18 / 30.40 | 2 | 2 |
2 | 3 | 1032.08 | 1 | 15.28 | 1619 | 25 | 0.20 / 30.42 | 2 | 2 |
3 | 7 | 2010.20 | 38 | 14.98 | 2709 | 1542 | 1.75 / 31.96 | 2 | 2 |
4 | 13 | 1359.28 | 18 | 15.08 | 1965 | 533 | 2.28 / 32.50 | 2 | 3 |
5 | 13 | 875.84 | 18 | 15.14 | 1389 | 379 | 2.66 / 32.88 | 2 | 5 |
6 | 13 | 188.48 | 18 | 15.30 | 532 | 147 | 2.80 / 33.02 | 2 | 7 |
7 | 8 | -0.04 | 165 | 15.31 | 278 | 702 | 3.51 / 33.73 | 2 | 18 |
Average= | 3.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 31 | 15.26 | 426 | 202 | 0.20 / 26.22 | 2 | 2 |
2 | 3 | 930.08 | -1 | 15.62 | 0 | 0 | 0.00 / 26.22 | 2 | 2 |
3 | 3 | 950.00 | -1 | 15.66 | 0 | 0 | 0.00 / 26.22 | 2 | 2 |
4 | 7 | 2012.24 | 75 | 14.88 | 2713 | 3028 | 3.23 / 29.25 | 2 | 4 |
5 | 13 | 548.32 | 18 | 15.23 | 986 | 270 | 3.50 / 29.52 | 2 | 6 |
6 | 8 | -0.08 | 165 | 15.32 | 278 | 703 | 4.20 / 30.22 | 2 | 16 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 28 | 15.25 | 425 | 181 | 0.18 / 22.32 | 2 | 2 |
2 | 3 | 1016.60 | 1 | 15.32 | 1588 | 24 | 0.21 / 22.34 | 2 | 2 |
3 | 7 | 1804.08 | 74 | 14.92 | 2462 | 2718 | 2.92 / 25.06 | 2 | 4 |
4 | 13 | 497.64 | 18 | 15.22 | 920 | 252 | 3.18 / 25.32 | 2 | 5 |
5 | 8 | 0.08 | 165 | 15.30 | 278 | 702 | 3.88 / 26.02 | 2 | 16 |
Average= | 3.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 28 | 15.25 | 420 | 179 | 0.18 / 18.43 | 2 | 2 |
2 | 3 | 1030.32 | 1 | 15.32 | 1617 | 25 | 0.20 / 18.45 | 2 | 2 |
3 | 7 | 1812.68 | 74 | 14.92 | 2476 | 2734 | 2.94 / 21.19 | 2 | 4 |
4 | 13 | 500.40 | 18 | 15.20 | 927 | 254 | 3.19 / 21.44 | 2 | 5 |
5 | 8 | 0.16 | 165 | 15.29 | 277 | 699 | 3.89 / 22.14 | 2 | 13 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 27 | 15.27 | 433 | 179 | 0.18 / 14.58 | 2 | 2 |
2 | 7 | 1804.08 | 74 | 14.92 | 2470 | 2727 | 2.91 / 17.30 | 2 | 4 |
3 | 13 | 473.76 | 18 | 15.22 | 892 | 244 | 3.15 / 17.55 | 2 | 6 |
4 | 8 | 0.00 | 165 | 15.30 | 278 | 702 | 3.85 / 18.25 | 2 | 17 |
Average= | 3.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 27 | 15.26 | 433 | 178 | 0.18 / 11.07 | 2 | 2 |
2 | 3 | 1026.92 | 1 | 15.33 | 1614 | 25 | 0.20 / 11.09 | 2 | 2 |
3 | 7 | 1509.32 | 75 | 15.04 | 2127 | 2399 | 2.60 / 13.49 | 2 | 4 |
4 | 13 | 361.60 | 18 | 15.28 | 751 | 207 | 2.81 / 13.70 | 2 | 6 |
5 | 8 | 0.24 | 165 | 15.32 | 277 | 700 | 3.51 / 14.40 | 2 | 17 |
Average= | 2.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 25 | 15.26 | 428 | 163 | 0.16 / 7.56 | 2 | 2 |
2 | 10 | 1003.68 | 3 | 15.25 | 1597 | 73 | 0.24 / 7.63 | 2 | 2 |
3 | 7 | 1506.80 | 74 | 15.04 | 2125 | 2365 | 2.60 / 10.00 | 2 | 4 |
4 | 13 | 329.76 | 18 | 15.28 | 709 | 195 | 2.80 / 10.19 | 2 | 6 |
5 | 8 | 0.44 | 165 | 15.31 | 275 | 695 | 3.49 / 10.89 | 2 | 17 |
Average= | 2.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 33 | 15.32 | 415 | 210 | 0.21 / 4.14 | 2 | 3 |
2 | 3 | 810.92 | -4 | 15.64 | 0 | 0 | 0.00 / 4.14 | 2 | 3 |
3 | 3 | 899.36 | -2 | 15.68 | 0 | 0 | 0.00 / 4.14 | 2 | 3 |
4 | 7 | 1524.96 | 74 | 15.04 | 2142 | 2384 | 2.59 / 6.53 | 2 | 4 |
5 | 13 | 284.92 | 18 | 15.29 | 651 | 179 | 2.77 / 6.71 | 2 | 6 |
6 | 8 | 0.08 | 165 | 15.32 | 273 | 690 | 3.46 / 7.40 | 2 | 19 |
Average= | 2.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 28 | 15.47 | 368 | 159 | 0.16 / 1.56 | 2 | 2 |
2 | 7 | 979.32 | 74 | 15.22 | 1487 | 1675 | 1.83 / 3.23 | 2 | 6 |
3 | 8 | -0.12 | 165 | 15.39 | 276 | 701 | 2.54 / 3.93 | 2 | 22 |
Average= | 1.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 28 | 15.60 | 353 | 154 | 0.15 / 0.15 | 2 | 2 |
2 | 7 | 115.08 | 74 | 15.56 | 366 | 421 | 0.58 / 0.58 | 2 | 3 |
3 | 8 | 0.52 | 240 | 15.52 | 221 | 823 | 1.40 / 1.40 | 2 | 19 |
Average= | 1.40 (KJ/cycle) |