SIO Argo Site:
Pump Diagnostics Page   



Serial= 3287 WMO= 5907035

Return

←PreviousNext→

Cycle 17 GMT 10/ 3/2025 22:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 30 15.21 477 218 0.22 / 60.92 2 3
2 7 2009.52 38 14.92 2890 1639 1.86 / 62.55 2 5
3 13 1391.60 18 15.02 2063 558 2.41 / 63.11 2 6
4 13 845.28 18 15.13 1363 371 2.79 / 63.48 2 8
5 13 156.16 18 15.27 523 144 2.93 / 63.63 2 7
6 8 -0.12 165 15.26 305 768 3.70 / 64.39 2 22
Average= 3.58
(KJ/cycle)

Cycle 16 GMT 1/ 3/2025 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 30 15.23 475 217 0.22 / 57.27 2 3
2 7 2010.96 38 14.93 2902 1646 1.86 / 58.91 2 3
3 13 1313.72 18 15.06 1906 517 2.38 / 59.43 2 6
4 13 838.16 18 15.12 1374 374 2.75 / 59.81 2 7
5 13 112.76 18 15.29 467 129 2.88 / 59.93 2 6
6 8 -0.16 165 15.28 303 764 3.65 / 60.70 2 16
Average= 3.57
(KJ/cycle)

Cycle 15 GMT 19/ 2/2025 8:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 15.23 459 210 0.21 / 53.55 2 3
2 7 2013.56 38 14.93 2909 1650 1.86 / 55.20 2 3
3 13 1349.32 18 15.04 2055 556 2.42 / 55.76 2 6
4 13 864.16 18 15.11 1394 379 2.80 / 56.14 2 6
5 13 163.68 18 15.28 536 147 2.94 / 56.28 2 8
6 8 0.00 165 15.28 304 766 3.71 / 57.05 2 21
Average= 3.57
(KJ/cycle)

Cycle 14 GMT 9/ 2/2025 14: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 30 15.24 467 214 0.21 / 49.90 2 2
2 7 2012.36 38 14.93 2915 1654 1.87 / 51.55 2 3
3 13 1344.24 18 15.05 1957 530 2.40 / 52.08 2 5
4 13 811.72 18 15.13 1334 363 2.76 / 52.45 2 7
5 13 129.32 18 15.29 490 135 2.90 / 52.58 2 7
6 8 0.32 165 15.28 302 761 3.66 / 53.34 2 22
Average= 3.56
(KJ/cycle)

Cycle 13 GMT 30/ 1/2025 19:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 30 15.23 475 217 0.22 / 46.20 2 3
2 7 2009.08 39 14.95 2894 1687 1.90 / 47.89 2 4
3 13 1393.96 18 15.03 2114 572 2.48 / 48.46 2 5
4 13 770.28 18 15.16 1255 342 2.82 / 48.81 2 6
5 13 175.80 18 15.29 514 141 2.96 / 48.95 2 8
6 8 -0.08 165 15.29 292 737 3.70 / 49.68 2 18
Average= 3.55
(KJ/cycle)

Cycle 12 GMT 21/ 1/2025 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 30 15.24 467 214 0.21 / 42.56 2 3
2 7 2004.92 38 14.97 2876 1636 1.85 / 44.20 2 4
3 13 1346.56 18 15.07 1972 535 2.38 / 44.74 2 6
4 13 768.92 18 15.16 1276 348 2.73 / 45.08 2 7
5 13 131.32 18 15.29 489 135 2.87 / 45.22 2 6
6 8 0.12 165 15.29 305 769 3.64 / 45.99 2 18
Average= 3.54
(KJ/cycle)

Cycle 11 GMT 11/ 1/2025 5:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 30 15.24 461 211 0.21 / 38.92 2 2
2 7 2006.00 38 14.95 2894 1644 1.85 / 40.56 2 3
3 13 1337.32 18 15.08 1966 534 2.39 / 41.09 2 4
4 13 809.08 18 15.17 1306 357 2.75 / 41.45 2 6
5 13 167.76 18 15.31 504 139 2.88 / 41.59 2 8
6 8 0.04 165 15.30 302 762 3.65 / 42.35 2 16
Average= 3.53
(KJ/cycle)

Cycle 10 GMT 1/ 1/2025 10:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 30 15.25 458 210 0.21 / 35.23 2 2
2 7 2008.36 38 14.95 2900 1647 1.86 / 36.88 2 4
3 13 1339.64 18 15.06 2039 553 2.41 / 37.43 2 5
4 13 764.24 18 15.16 1304 356 2.77 / 37.79 2 6
5 13 178.72 18 15.29 557 153 2.92 / 37.94 2 7
6 8 0.16 165 15.30 303 765 3.68 / 38.70 2 17
Average= 3.52
(KJ/cycle)

Cycle 9 GMT 22/12/2024 16: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 15.24 453 200 0.20 / 31.61 2 3
2 3 1017.80 1 15.24 1715 26 0.23 / 31.64 2 2
3 7 2004.04 38 14.96 2866 1629 1.86 / 33.26 2 4
4 13 1379.80 18 15.05 2067 560 2.42 / 33.82 2 6
5 13 797.72 18 15.16 1275 348 2.76 / 34.17 2 7
6 13 117.28 18 15.31 432 119 2.88 / 34.29 2 8
7 8 0.04 165 15.29 289 729 3.61 / 35.02 2 18
Average= 3.50
(KJ/cycle)

Cycle 8 GMT 12/12/2024 21:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 31 15.22 463 218 0.22 / 27.32 2 3
2 3 931.60 -1 15.57 0 0 0.00 / 27.32 2 3
3 7 2004.44 74 14.83 2848 3125 3.34 / 30.45 2 6
4 13 373.32 18 15.27 765 210 3.55 / 30.66 2 6
5 8 0.04 165 15.31 298 753 4.31 / 31.41 2 17
Average= 3.49
(KJ/cycle)

Cycle 7 GMT 3/12/2024 0: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 29 15.24 455 201 0.20 / 23.26 2 2
2 7 1810.96 75 14.89 2605 2909 3.11 / 26.17 2 8
3 13 292.32 18 15.26 691 190 3.30 / 26.36 2 6
4 8 0.20 165 15.29 296 747 4.05 / 27.10 2 17
Average= 3.39
(KJ/cycle)

Cycle 6 GMT 1/12/2024 23:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 28 15.25 456 195 0.19 / 19.22 2 3
2 3 1022.40 1 15.33 1656 25 0.22 / 19.24 2 3
3 7 1814.12 74 14.91 2592 2860 3.08 / 22.10 2 5
4 13 350.36 18 15.24 754 207 3.29 / 22.31 2 6
5 8 0.08 165 15.29 295 744 4.03 / 23.06 2 16
Average= 3.29
(KJ/cycle)

Cycle 5 GMT 30/11/2024 22:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 28 15.26 458 196 0.20 / 15.19 2 2
2 7 1816.32 74 14.90 2625 2894 3.09 / 18.09 2 6
3 13 318.60 18 15.27 716 197 3.29 / 18.28 2 6
4 8 0.12 165 15.30 293 740 4.03 / 19.02 2 18
Average= 3.17
(KJ/cycle)

Cycle 4 GMT 29/11/2024 21:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 15.26 454 194 0.19 / 11.64 2 2
2 7 1513.56 74 15.02 2221 2469 2.66 / 14.11 2 7
3 13 156.48 18 15.32 520 143 2.81 / 14.25 2 7
4 8 0.00 165 15.32 296 748 3.55 / 15.00 2 17
Average= 3.00
(KJ/cycle)

Cycle 3 GMT 28/11/2024 22:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 15.26 453 187 0.19 / 8.08 2 3
2 3 1033.76 1 15.29 1699 26 0.21 / 8.10 2 3
3 7 1509.76 74 15.02 2204 2450 2.66 / 10.55 2 7
4 13 169.12 18 15.31 536 148 2.81 / 10.70 2 6
5 8 0.12 165 15.30 294 742 3.55 / 11.44 2 17
Average= 2.86
(KJ/cycle)

Cycle 2 GMT 27/11/2024 23: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 33 15.30 449 227 0.23 / 4.50 2 4
2 3 788.80 -4 15.61 0 0 0.00 / 4.50 2 4
3 3 952.08 -1 15.64 0 0 0.00 / 4.50 2 4
4 7 1508.32 75 15.02 2221 2502 2.73 / 7.00 2 6
5 13 191.40 18 15.30 560 154 2.88 / 7.15 2 6
6 8 0.08 165 15.31 292 738 3.62 / 7.89 2 16
Average= 2.63
(KJ/cycle)

Cycle 1 GMT 26/11/2024 23:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 28 15.46 427 185 0.18 / 1.75 2 2
2 3 970.08 -1 15.64 0 0 0.00 / 1.75 2 2
3 3 1025.88 1 15.36 1578 24 0.21 / 1.77 2 3
4 7 1001.44 75 15.19 1548 1764 1.97 / 3.54 2 7
5 8 -0.04 165 15.37 290 735 2.71 / 4.27 2 19
Average= 2.14
(KJ/cycle)

Cycle 0 GMT 26/11/2024 13: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.96 28 15.61 426 186 0.19 / 0.19 2 3
2 7 136.56 74 15.58 441 508 0.69 / 0.69 2 4
3 8 0.36 229 15.54 244 868 1.56 / 1.56 2 235
Average= 1.56
(KJ/cycle)