SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 47 | 15.18 | 421 | 300 | 0.30 / 144.81 | 2 | 2 |
2 | 3 | 910.88 | -2 | 15.49 | 1 | 0 | 0.00 / 144.81 | 2 | 2 |
3 | 3 | 1339.24 | 10 | 15.09 | 1924 | 290 | 0.59 / 145.10 | 2 | 3 |
4 | 5 | 1363.80 | 10 | 15.04 | 2022 | 304 | 0.89 / 145.41 | 2 | 3 |
5 | 7 | 2004.04 | 38 | 14.79 | 2760 | 1551 | 2.45 / 146.96 | 2 | 5 |
6 | 13 | 1503.32 | 18 | 14.90 | 2130 | 571 | 3.02 / 147.53 | 2 | 4 |
7 | 13 | 1035.84 | 18 | 14.95 | 1568 | 422 | 3.44 / 147.95 | 2 | 8 |
8 | 13 | 655.92 | 18 | 15.05 | 1123 | 304 | 3.74 / 148.26 | 2 | 8 |
9 | 13 | 220.96 | 18 | 15.17 | 594 | 162 | 3.91 / 148.42 | 2 | 8 |
10 | 13 | 16.12 | 18 | 15.23 | 306 | 84 | 3.99 / 148.50 | 2 | 11 |
11 | 8 | 0.04 | 165 | 15.19 | 284 | 712 | 4.70 / 149.22 | 2 | 17 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 39 | 15.18 | 425 | 252 | 0.25 / 140.24 | 2 | 3 |
2 | 10 | 1017.44 | 3 | 15.20 | 1524 | 69 | 0.32 / 140.31 | 2 | 2 |
3 | 3 | 1049.44 | 1 | 15.21 | 1578 | 24 | 0.35 / 140.33 | 2 | 2 |
4 | 3 | 1085.20 | 2 | 15.19 | 1580 | 48 | 0.39 / 140.38 | 2 | 2 |
5 | 5 | 1394.96 | 11 | 15.07 | 2081 | 345 | 0.74 / 140.73 | 2 | 3 |
6 | 5 | 1301.44 | 8 | 15.13 | 1938 | 235 | 0.97 / 140.96 | 2 | 2 |
7 | 7 | 2003.72 | 38 | 14.81 | 2751 | 1548 | 2.52 / 142.51 | 2 | 5 |
8 | 13 | 1318.52 | 18 | 14.94 | 1879 | 505 | 3.03 / 143.01 | 2 | 4 |
9 | 13 | 908.40 | 18 | 15.01 | 1416 | 383 | 3.41 / 143.40 | 2 | 7 |
10 | 13 | 571.08 | 18 | 15.09 | 1017 | 276 | 3.68 / 143.67 | 2 | 9 |
11 | 13 | 193.56 | 18 | 15.19 | 545 | 149 | 3.83 / 143.82 | 2 | 8 |
12 | 8 | 0.12 | 165 | 15.21 | 276 | 693 | 4.53 / 144.51 | 2 | 18 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 58 | 15.18 | 421 | 371 | 0.37 / 136.48 | 2 | 3 |
2 | 3 | 267.96 | -18 | 15.52 | 0 | 0 | 0.00 / 136.48 | 2 | 3 |
3 | 3 | 852.80 | -4 | 15.55 | 0 | 0 | 0.00 / 136.48 | 2 | 3 |
4 | 7 | 2004.40 | 38 | 14.81 | 2685 | 1511 | 1.88 / 138.00 | 2 | 4 |
5 | 13 | 1348.92 | 18 | 14.93 | 1916 | 515 | 2.40 / 138.51 | 2 | 6 |
6 | 13 | 935.08 | 18 | 15.00 | 1436 | 388 | 2.78 / 138.90 | 2 | 7 |
7 | 13 | 515.32 | 18 | 15.09 | 958 | 260 | 3.04 / 139.16 | 2 | 8 |
8 | 13 | 133.84 | 18 | 15.20 | 472 | 129 | 3.17 / 139.29 | 2 | 7 |
9 | 8 | 0.04 | 165 | 15.20 | 279 | 700 | 3.87 / 139.99 | 2 | 15 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 57 | 15.18 | 434 | 376 | 0.38 / 131.43 | 2 | 4 |
2 | 3 | 592.72 | -10 | 15.51 | 0 | 0 | 0.00 / 131.43 | 2 | 4 |
3 | 3 | 1114.60 | 3 | 15.18 | 1786 | 81 | 0.46 / 131.51 | 2 | 2 |
4 | 5 | 1348.92 | 10 | 15.03 | 1994 | 300 | 0.76 / 131.81 | 2 | 2 |
5 | 5 | 1356.44 | 10 | 15.09 | 1975 | 298 | 1.05 / 132.11 | 2 | 3 |
6 | 5 | 1380.72 | 11 | 15.09 | 1891 | 314 | 1.37 / 132.43 | 2 | 2 |
7 | 7 | 2007.32 | 38 | 14.82 | 2708 | 1525 | 2.89 / 133.95 | 2 | 3 |
8 | 13 | 1488.28 | 18 | 14.90 | 2084 | 559 | 3.45 / 134.51 | 2 | 5 |
9 | 13 | 1056.84 | 18 | 14.98 | 1577 | 425 | 3.88 / 134.94 | 2 | 6 |
10 | 13 | 626.00 | 18 | 15.07 | 1078 | 292 | 4.17 / 135.23 | 2 | 8 |
11 | 13 | 253.32 | 18 | 15.17 | 635 | 173 | 4.34 / 135.40 | 2 | 8 |
12 | 8 | 0.24 | 165 | 15.21 | 284 | 713 | 5.06 / 136.11 | 2 | 18 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 44 | 15.18 | 417 | 279 | 0.28 / 126.89 | 2 | 2 |
2 | 3 | 1292.48 | 8 | 15.10 | 1953 | 236 | 0.51 / 127.12 | 2 | 2 |
3 | 5 | 1304.72 | 9 | 15.07 | 1972 | 267 | 0.78 / 127.39 | 2 | 3 |
4 | 7 | 2014.84 | 38 | 14.80 | 2761 | 1553 | 2.33 / 128.94 | 2 | 4 |
5 | 13 | 1434.76 | 18 | 14.91 | 2020 | 542 | 2.88 / 129.49 | 2 | 5 |
6 | 13 | 1012.00 | 18 | 15.00 | 1526 | 412 | 3.29 / 129.90 | 2 | 7 |
7 | 13 | 610.84 | 18 | 15.07 | 1061 | 288 | 3.58 / 130.19 | 2 | 9 |
8 | 13 | 214.84 | 18 | 15.19 | 588 | 161 | 3.74 / 130.35 | 2 | 8 |
9 | 8 | 0.08 | 165 | 15.21 | 283 | 710 | 4.45 / 131.06 | 2 | 14 |
Average= | 4.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 39 | 15.17 | 418 | 247 | 0.25 / 120.00 | 2 | 2 |
2 | 3 | 923.96 | -2 | 15.51 | 0 | 0 | 0.00 / 120.00 | 2 | 2 |
3 | 3 | 1139.28 | 4 | 15.15 | 1727 | 105 | 0.35 / 120.11 | 2 | 2 |
4 | 5 | 1446.48 | 13 | 15.02 | 2205 | 431 | 0.78 / 120.54 | 2 | 3 |
5 | 5 | 1377.00 | 11 | 15.10 | 2052 | 341 | 1.12 / 120.88 | 2 | 3 |
6 | 5 | 1328.04 | 9 | 15.10 | 1979 | 269 | 1.39 / 121.15 | 2 | 3 |
7 | 5 | 1311.88 | 9 | 15.08 | 1972 | 268 | 1.66 / 121.41 | 2 | 3 |
8 | 5 | 1580.84 | 16 | 14.97 | 2325 | 557 | 2.22 / 121.97 | 2 | 3 |
9 | 5 | 1446.56 | 13 | 15.01 | 2211 | 431 | 2.65 / 122.40 | 2 | 3 |
10 | 5 | 1336.08 | 9 | 15.08 | 2015 | 273 | 2.92 / 122.68 | 2 | 3 |
11 | 5 | 1342.64 | 10 | 15.08 | 1990 | 300 | 3.22 / 122.98 | 2 | 3 |
12 | 7 | 2013.20 | 38 | 14.84 | 2657 | 1498 | 4.72 / 124.47 | 2 | 5 |
13 | 13 | 1492.48 | 18 | 14.91 | 2094 | 562 | 5.28 / 125.04 | 2 | 4 |
14 | 13 | 1013.56 | 18 | 15.00 | 1535 | 414 | 5.70 / 125.45 | 2 | 6 |
15 | 13 | 630.68 | 18 | 15.08 | 1090 | 296 | 5.99 / 125.75 | 2 | 9 |
16 | 13 | 243.32 | 18 | 15.18 | 613 | 167 | 6.16 / 125.91 | 2 | 7 |
17 | 8 | 0.28 | 165 | 15.22 | 277 | 696 | 6.86 / 126.61 | 2 | 13 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 33 | 15.20 | 418 | 210 | 0.21 / 113.83 | 2 | 2 |
2 | 10 | 1019.36 | 3 | 15.24 | 1524 | 70 | 0.28 / 113.90 | 2 | 2 |
3 | 10 | 1057.80 | 2 | 15.17 | 1711 | 52 | 0.33 / 113.95 | 2 | 2 |
4 | 3 | 1046.08 | 1 | 15.19 | 1655 | 25 | 0.36 / 113.98 | 2 | 2 |
5 | 5 | 1300.92 | 8 | 15.16 | 1966 | 238 | 0.59 / 114.22 | 2 | 3 |
6 | 5 | 1447.24 | 13 | 15.09 | 2086 | 409 | 1.00 / 114.63 | 2 | 3 |
7 | 5 | 1339.92 | 10 | 15.11 | 2033 | 307 | 1.31 / 114.93 | 2 | 3 |
8 | 5 | 1349.36 | 10 | 15.16 | 1878 | 285 | 1.60 / 115.22 | 2 | 2 |
9 | 5 | 1394.00 | 11 | 15.07 | 2149 | 356 | 1.95 / 115.57 | 2 | 3 |
10 | 5 | 1326.04 | 9 | 15.17 | 1845 | 252 | 2.20 / 115.83 | 2 | 3 |
11 | 7 | 2011.08 | 38 | 14.83 | 2735 | 1541 | 3.75 / 117.37 | 2 | 4 |
12 | 13 | 1605.40 | 18 | 14.89 | 2208 | 592 | 4.34 / 117.96 | 2 | 4 |
13 | 13 | 1161.20 | 18 | 14.96 | 1723 | 464 | 4.80 / 118.42 | 2 | 6 |
14 | 13 | 723.08 | 18 | 15.05 | 1204 | 326 | 5.13 / 118.75 | 2 | 10 |
15 | 13 | 325.24 | 18 | 15.16 | 718 | 196 | 5.32 / 118.94 | 2 | 7 |
16 | 13 | 68.56 | 18 | 15.23 | 381 | 104 | 5.43 / 119.05 | 2 | 8 |
17 | 8 | 0.16 | 165 | 15.21 | 281 | 705 | 6.13 / 119.75 | 2 | 12 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 38 | 15.20 | 425 | 245 | 0.25 / 109.65 | 2 | 2 |
2 | 3 | 768.64 | -6 | 15.52 | 0 | 0 | 0.00 / 109.65 | 2 | 2 |
3 | 7 | 2008.48 | 39 | 14.85 | 2698 | 1563 | 1.81 / 111.21 | 2 | 4 |
4 | 13 | 1550.84 | 18 | 14.92 | 2152 | 578 | 2.39 / 111.79 | 2 | 4 |
5 | 13 | 1143.20 | 18 | 14.97 | 1660 | 447 | 2.83 / 112.23 | 2 | 6 |
6 | 13 | 769.68 | 18 | 15.05 | 1239 | 336 | 3.17 / 112.57 | 2 | 7 |
7 | 13 | 398.68 | 18 | 15.15 | 809 | 221 | 3.39 / 112.79 | 2 | 6 |
8 | 13 | 98.08 | 18 | 15.24 | 421 | 115 | 3.51 / 112.91 | 2 | 8 |
9 | 8 | 0.08 | 165 | 15.22 | 285 | 716 | 4.22 / 113.62 | 2 | 14 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 53 | 15.21 | 420 | 339 | 0.34 / 104.56 | 2 | 2 |
2 | 3 | 421.72 | -14 | 15.55 | 0 | 0 | 0.00 / 104.56 | 2 | 2 |
3 | 3 | 891.08 | -3 | 15.57 | 1 | 0 | 0.00 / 104.56 | 2 | 2 |
4 | 5 | 1319.44 | 9 | 15.20 | 1828 | 250 | 0.59 / 104.81 | 2 | 2 |
5 | 5 | 1300.56 | 8 | 15.19 | 1892 | 230 | 0.82 / 105.04 | 2 | 3 |
6 | 5 | 1322.92 | 9 | 15.12 | 2079 | 283 | 1.10 / 105.33 | 2 | 3 |
7 | 5 | 1352.56 | 10 | 15.15 | 1941 | 294 | 1.40 / 105.62 | 2 | 3 |
8 | 7 | 2006.60 | 38 | 14.84 | 2742 | 1546 | 2.94 / 107.17 | 2 | 3 |
9 | 13 | 1458.12 | 18 | 14.94 | 2070 | 557 | 3.50 / 107.72 | 2 | 5 |
10 | 13 | 1071.08 | 18 | 15.00 | 1590 | 429 | 3.93 / 108.15 | 2 | 6 |
11 | 13 | 558.88 | 18 | 15.12 | 1008 | 274 | 4.20 / 108.43 | 2 | 11 |
12 | 13 | 234.52 | 18 | 15.20 | 612 | 167 | 4.37 / 108.59 | 2 | 8 |
13 | 13 | 45.16 | 18 | 15.25 | 351 | 96 | 4.47 / 108.69 | 2 | 8 |
14 | 8 | 0.08 | 165 | 15.22 | 283 | 711 | 5.18 / 109.40 | 2 | 20 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 56 | 15.19 | 416 | 354 | 0.35 / 98.05 | 2 | 3 |
2 | 3 | 416.16 | -14 | 15.53 | 0 | 0 | 0.00 / 98.05 | 2 | 3 |
3 | 3 | 1027.20 | 1 | 15.28 | 1632 | 25 | 0.38 / 98.08 | 2 | 2 |
4 | 5 | 1404.16 | 11 | 15.06 | 2101 | 348 | 0.73 / 98.43 | 2 | 2 |
5 | 5 | 1343.88 | 10 | 15.08 | 1996 | 301 | 1.03 / 98.73 | 2 | 3 |
6 | 5 | 1308.20 | 9 | 15.14 | 1901 | 259 | 1.29 / 98.99 | 2 | 3 |
7 | 5 | 1349.28 | 10 | 15.11 | 2031 | 307 | 1.59 / 99.29 | 2 | 3 |
8 | 5 | 1313.88 | 9 | 15.20 | 1857 | 254 | 1.85 / 99.55 | 2 | 3 |
9 | 5 | 1313.32 | 9 | 15.19 | 1967 | 269 | 2.12 / 99.81 | 2 | 3 |
10 | 5 | 1629.52 | 18 | 15.03 | 2282 | 617 | 2.73 / 100.43 | 2 | 3 |
11 | 7 | 2007.32 | 38 | 14.84 | 2756 | 1554 | 4.29 / 101.99 | 2 | 4 |
12 | 13 | 1465.32 | 18 | 14.93 | 2054 | 552 | 4.84 / 102.54 | 2 | 5 |
13 | 13 | 1060.96 | 18 | 15.01 | 1570 | 424 | 5.26 / 102.96 | 2 | 7 |
14 | 13 | 653.56 | 18 | 15.10 | 1117 | 304 | 5.57 / 103.27 | 2 | 10 |
15 | 13 | 206.84 | 18 | 15.22 | 574 | 157 | 5.73 / 103.42 | 2 | 7 |
16 | 13 | 32.72 | 18 | 15.27 | 333 | 92 | 5.82 / 103.52 | 2 | 6 |
17 | 8 | 0.04 | 165 | 15.24 | 282 | 709 | 6.53 / 104.22 | 2 | 11 |
Average= | 4.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 52 | 15.19 | 434 | 343 | 0.34 / 92.45 | 2 | 3 |
2 | 3 | 744.72 | -6 | 15.54 | 0 | 0 | 0.00 / 92.45 | 2 | 3 |
3 | 3 | 1186.52 | 5 | 15.17 | 1803 | 137 | 0.48 / 92.58 | 2 | 2 |
4 | 5 | 1422.76 | 12 | 15.06 | 2079 | 376 | 0.86 / 92.96 | 2 | 3 |
5 | 5 | 1372.08 | 10 | 15.15 | 1933 | 293 | 1.15 / 93.25 | 2 | 3 |
6 | 5 | 1364.88 | 10 | 15.12 | 1960 | 296 | 1.44 / 93.55 | 2 | 3 |
7 | 5 | 1376.44 | 11 | 15.14 | 2008 | 334 | 1.78 / 93.88 | 2 | 3 |
8 | 7 | 2006.68 | 38 | 14.86 | 2692 | 1520 | 3.30 / 95.40 | 2 | 5 |
9 | 13 | 1504.08 | 18 | 14.95 | 2084 | 561 | 3.86 / 95.96 | 2 | 4 |
10 | 13 | 1162.04 | 18 | 14.97 | 1690 | 455 | 4.32 / 96.42 | 2 | 7 |
11 | 13 | 663.00 | 18 | 15.09 | 1131 | 307 | 4.62 / 96.73 | 2 | 8 |
12 | 13 | 284.92 | 18 | 15.19 | 663 | 181 | 4.80 / 96.91 | 2 | 7 |
13 | 13 | 51.80 | 18 | 15.25 | 355 | 97 | 4.90 / 97.00 | 2 | 7 |
14 | 8 | 0.08 | 165 | 15.23 | 276 | 694 | 5.59 / 97.70 | 2 | 18 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 47 | 15.22 | 422 | 302 | 0.30 / 86.79 | 2 | 3 |
2 | 3 | 820.32 | -4 | 15.55 | 1 | 0 | 0.00 / 86.79 | 2 | 3 |
3 | 3 | 1114.84 | 3 | 15.23 | 1633 | 75 | 0.38 / 86.86 | 2 | 3 |
4 | 5 | 1628.44 | 18 | 14.95 | 2301 | 619 | 1.00 / 87.48 | 2 | 2 |
5 | 5 | 1316.36 | 9 | 15.09 | 1941 | 264 | 1.26 / 87.74 | 2 | 3 |
6 | 5 | 1539.36 | 15 | 15.00 | 2336 | 526 | 1.78 / 88.27 | 2 | 4 |
7 | 7 | 2006.56 | 38 | 14.84 | 2760 | 1556 | 3.34 / 89.82 | 2 | 4 |
8 | 13 | 1519.72 | 18 | 14.95 | 2123 | 571 | 3.91 / 90.40 | 2 | 5 |
9 | 13 | 1033.28 | 18 | 15.03 | 1512 | 409 | 4.32 / 90.81 | 2 | 7 |
10 | 13 | 646.48 | 18 | 15.10 | 1098 | 298 | 4.62 / 91.10 | 2 | 6 |
11 | 13 | 254.44 | 18 | 15.20 | 633 | 173 | 4.79 / 91.28 | 2 | 7 |
12 | 13 | 59.68 | 18 | 15.25 | 375 | 103 | 4.90 / 91.38 | 2 | 9 |
13 | 8 | 0.12 | 165 | 15.23 | 288 | 724 | 5.62 / 92.10 | 2 | 18 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 34 | 15.21 | 420 | 217 | 0.22 / 82.26 | 2 | 2 |
2 | 10 | 1047.16 | 2 | 15.20 | 1663 | 51 | 0.27 / 82.31 | 2 | 2 |
3 | 3 | 1124.52 | 4 | 15.13 | 1777 | 108 | 0.38 / 82.41 | 2 | 2 |
4 | 3 | 1165.00 | 5 | 15.13 | 1837 | 139 | 0.51 / 82.55 | 2 | 2 |
5 | 5 | 1319.40 | 9 | 15.12 | 1906 | 259 | 0.77 / 82.81 | 2 | 2 |
6 | 7 | 2006.72 | 38 | 14.88 | 2657 | 1502 | 2.28 / 84.32 | 2 | 4 |
7 | 13 | 1407.52 | 18 | 14.98 | 1996 | 538 | 2.81 / 84.85 | 2 | 4 |
8 | 13 | 969.96 | 18 | 15.04 | 1472 | 398 | 3.21 / 85.25 | 2 | 7 |
9 | 13 | 585.32 | 18 | 15.12 | 1025 | 279 | 3.49 / 85.53 | 2 | 9 |
10 | 13 | 210.64 | 18 | 15.23 | 580 | 159 | 3.65 / 85.69 | 2 | 8 |
11 | 13 | 37.04 | 18 | 15.27 | 334 | 92 | 3.74 / 85.78 | 2 | 5 |
12 | 8 | 0.16 | 165 | 15.24 | 279 | 702 | 4.44 / 86.48 | 2 | 16 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 44 | 15.20 | 411 | 275 | 0.27 / 78.21 | 2 | 3 |
2 | 3 | 616.40 | -9 | 15.52 | 0 | 0 | 0.00 / 78.21 | 2 | 3 |
3 | 3 | 929.52 | -2 | 15.56 | 0 | 0 | 0.00 / 78.21 | 2 | 3 |
4 | 7 | 2013.16 | 38 | 14.84 | 2764 | 1559 | 1.83 / 79.77 | 2 | 3 |
5 | 13 | 1509.80 | 18 | 14.93 | 2101 | 565 | 2.40 / 80.33 | 2 | 5 |
6 | 13 | 1028.80 | 18 | 15.03 | 1522 | 412 | 2.81 / 80.74 | 2 | 6 |
7 | 13 | 614.56 | 18 | 15.11 | 1077 | 293 | 3.10 / 81.04 | 2 | 8 |
8 | 13 | 286.64 | 18 | 15.20 | 674 | 184 | 3.29 / 81.22 | 2 | 8 |
9 | 13 | 78.60 | 18 | 15.25 | 398 | 109 | 3.40 / 81.33 | 2 | 8 |
10 | 8 | 0.08 | 165 | 15.23 | 282 | 709 | 4.11 / 82.04 | 2 | 22 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 41 | 15.21 | 421 | 263 | 0.26 / 73.20 | 2 | 2 |
2 | 3 | 822.64 | -4 | 15.53 | 0 | 0 | 0.00 / 73.20 | 2 | 2 |
3 | 3 | 1059.84 | 2 | 15.24 | 1531 | 47 | 0.31 / 73.25 | 2 | 2 |
4 | 5 | 1592.12 | 17 | 14.95 | 2386 | 606 | 0.92 / 73.85 | 2 | 2 |
5 | 5 | 1374.88 | 11 | 15.12 | 1973 | 328 | 1.24 / 74.18 | 2 | 3 |
6 | 7 | 2008.04 | 38 | 14.83 | 2754 | 1552 | 2.80 / 75.73 | 2 | 5 |
7 | 13 | 1409.64 | 18 | 14.96 | 1958 | 527 | 3.32 / 76.26 | 2 | 4 |
8 | 13 | 1063.40 | 18 | 15.01 | 1571 | 424 | 3.75 / 76.68 | 2 | 6 |
9 | 13 | 577.32 | 18 | 15.12 | 1025 | 279 | 4.03 / 76.96 | 2 | 8 |
10 | 13 | 239.08 | 18 | 15.21 | 612 | 168 | 4.19 / 77.13 | 2 | 7 |
11 | 13 | 40.40 | 18 | 15.26 | 347 | 95 | 4.29 / 77.23 | 2 | 8 |
12 | 8 | 0.04 | 165 | 15.23 | 282 | 709 | 5.00 / 77.93 | 2 | 17 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.80 | 49 | 15.22 | 425 | 317 | 0.32 / 68.66 | 2 | 3 |
2 | 3 | 564.96 | -10 | 15.55 | 0 | 0 | 0.00 / 68.66 | 2 | 3 |
3 | 3 | 958.76 | -1 | 15.57 | 0 | 0 | 0.00 / 68.66 | 2 | 3 |
4 | 5 | 1361.40 | 10 | 15.14 | 1946 | 295 | 0.61 / 68.96 | 2 | 3 |
5 | 5 | 1301.24 | 8 | 15.13 | 1993 | 241 | 0.85 / 69.20 | 2 | 3 |
6 | 7 | 2008.00 | 38 | 14.88 | 2709 | 1532 | 2.38 / 70.73 | 2 | 4 |
7 | 13 | 1481.68 | 18 | 14.95 | 2064 | 555 | 2.94 / 71.28 | 2 | 5 |
8 | 13 | 954.20 | 18 | 15.05 | 1448 | 392 | 3.33 / 71.68 | 2 | 6 |
9 | 13 | 605.68 | 18 | 15.11 | 1048 | 285 | 3.62 / 71.96 | 2 | 9 |
10 | 13 | 258.00 | 18 | 15.20 | 624 | 171 | 3.79 / 72.13 | 2 | 8 |
11 | 13 | 54.88 | 18 | 15.25 | 359 | 99 | 3.89 / 72.23 | 2 | 8 |
12 | 8 | 0.00 | 165 | 15.23 | 281 | 706 | 4.59 / 72.94 | 2 | 17 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 40 | 15.22 | 412 | 251 | 0.25 / 63.84 | 2 | 2 |
2 | 10 | 1007.88 | 3 | 15.24 | 1532 | 70 | 0.32 / 63.91 | 2 | 2 |
3 | 3 | 1029.96 | 1 | 15.24 | 1633 | 25 | 0.35 / 63.93 | 2 | 2 |
4 | 3 | 1173.64 | 5 | 15.20 | 1752 | 133 | 0.48 / 64.06 | 2 | 2 |
5 | 5 | 1323.88 | 9 | 15.21 | 1988 | 272 | 0.75 / 64.34 | 2 | 2 |
6 | 5 | 1377.60 | 11 | 15.17 | 1965 | 328 | 1.08 / 64.66 | 2 | 2 |
7 | 7 | 2005.96 | 38 | 14.86 | 2689 | 1518 | 2.60 / 66.18 | 2 | 3 |
8 | 13 | 1386.88 | 18 | 14.96 | 1961 | 528 | 3.13 / 66.71 | 2 | 5 |
9 | 13 | 1006.04 | 18 | 15.03 | 1477 | 400 | 3.53 / 67.11 | 2 | 6 |
10 | 13 | 529.96 | 18 | 15.14 | 975 | 266 | 3.79 / 67.38 | 2 | 8 |
11 | 13 | 242.80 | 18 | 15.22 | 610 | 167 | 3.96 / 67.54 | 2 | 7 |
12 | 13 | 41.28 | 18 | 15.28 | 345 | 95 | 4.05 / 67.64 | 2 | 6 |
13 | 8 | 0.12 | 165 | 15.24 | 281 | 707 | 4.76 / 68.34 | 2 | 20 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 56 | 15.22 | 414 | 353 | 0.35 / 59.76 | 2 | 3 |
2 | 3 | 413.24 | -14 | 15.56 | 0 | 0 | 0.00 / 59.76 | 2 | 3 |
3 | 3 | 872.40 | -3 | 15.60 | 0 | 0 | 0.00 / 59.76 | 2 | 3 |
4 | 7 | 2014.76 | 38 | 14.86 | 2716 | 1534 | 1.89 / 61.29 | 2 | 3 |
5 | 13 | 1534.36 | 18 | 14.95 | 2155 | 580 | 2.47 / 61.87 | 2 | 4 |
6 | 13 | 1120.00 | 18 | 15.00 | 1642 | 443 | 2.91 / 62.31 | 2 | 6 |
7 | 13 | 676.84 | 18 | 15.10 | 1143 | 311 | 3.22 / 62.62 | 2 | 9 |
8 | 13 | 255.56 | 18 | 15.21 | 619 | 169 | 3.39 / 62.79 | 2 | 7 |
9 | 13 | 76.72 | 18 | 15.26 | 384 | 105 | 3.50 / 62.90 | 2 | 7 |
10 | 8 | 0.12 | 165 | 15.24 | 273 | 686 | 4.18 / 63.58 | 2 | 11 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 36 | 15.23 | 419 | 230 | 0.23 / 53.82 | 2 | 2 |
2 | 10 | 1093.76 | 5 | 15.18 | 1680 | 128 | 0.36 / 53.95 | 2 | 2 |
3 | 10 | 1143.32 | 3 | 15.19 | 1719 | 78 | 0.44 / 54.03 | 2 | 2 |
4 | 10 | 1171.36 | 2 | 15.21 | 1683 | 51 | 0.49 / 54.08 | 2 | 2 |
5 | 3 | 1188.20 | 5 | 15.15 | 1744 | 132 | 0.62 / 54.21 | 2 | 2 |
6 | 3 | 1196.72 | 6 | 15.20 | 1738 | 159 | 0.78 / 54.37 | 2 | 2 |
7 | 5 | 1300.80 | 8 | 15.17 | 1926 | 234 | 1.01 / 54.61 | 2 | 2 |
8 | 5 | 1389.56 | 11 | 15.11 | 2092 | 348 | 1.36 / 54.95 | 2 | 2 |
9 | 5 | 1315.84 | 9 | 15.19 | 1971 | 269 | 1.63 / 55.22 | 2 | 3 |
10 | 5 | 1347.88 | 10 | 15.14 | 2039 | 309 | 1.94 / 55.53 | 2 | 3 |
11 | 7 | 2010.28 | 38 | 14.86 | 2765 | 1561 | 3.50 / 57.09 | 2 | 5 |
12 | 13 | 1543.08 | 18 | 14.95 | 2148 | 578 | 4.08 / 57.67 | 2 | 4 |
13 | 13 | 983.80 | 18 | 15.05 | 1467 | 397 | 4.47 / 58.07 | 2 | 6 |
14 | 13 | 619.52 | 18 | 15.11 | 1078 | 293 | 4.77 / 58.36 | 2 | 9 |
15 | 13 | 279.88 | 18 | 15.21 | 651 | 178 | 4.95 / 58.54 | 2 | 7 |
16 | 13 | 55.96 | 18 | 15.27 | 353 | 97 | 5.04 / 58.64 | 2 | 6 |
17 | 13 | 12.96 | 18 | 15.27 | 294 | 81 | 5.12 / 58.72 | 2 | 5 |
18 | 8 | 0.04 | 165 | 15.25 | 272 | 684 | 5.81 / 59.40 | 2 | 15 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 33 | 15.24 | 408 | 205 | 0.21 / 49.23 | 2 | 2 |
2 | 5 | 1474.32 | 13 | 15.10 | 2159 | 424 | 0.63 / 49.65 | 2 | 3 |
3 | 5 | 1412.56 | 12 | 15.12 | 2016 | 366 | 0.99 / 50.02 | 2 | 3 |
4 | 7 | 2006.40 | 38 | 14.90 | 2681 | 1518 | 2.51 / 51.54 | 2 | 5 |
5 | 13 | 1415.48 | 18 | 14.99 | 1952 | 527 | 3.04 / 52.06 | 2 | 4 |
6 | 13 | 852.88 | 18 | 15.09 | 1336 | 363 | 3.40 / 52.43 | 2 | 6 |
7 | 13 | 518.88 | 18 | 15.16 | 954 | 260 | 3.66 / 52.69 | 2 | 9 |
8 | 13 | 140.88 | 18 | 15.26 | 477 | 131 | 3.79 / 52.82 | 2 | 7 |
9 | 13 | 52.88 | 18 | 15.28 | 349 | 96 | 3.89 / 52.91 | 2 | 7 |
10 | 8 | 0.04 | 165 | 15.26 | 271 | 682 | 4.57 / 53.60 | 2 | 14 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 43 | 15.25 | 410 | 269 | 0.27 / 45.14 | 2 | 2 |
2 | 3 | 637.08 | -9 | 15.56 | 0 | 0 | 0.00 / 45.14 | 2 | 2 |
3 | 3 | 944.76 | -1 | 15.58 | 0 | 0 | 0.00 / 45.14 | 2 | 2 |
4 | 7 | 2003.28 | 38 | 14.92 | 2664 | 1510 | 1.78 / 46.65 | 2 | 4 |
5 | 13 | 1564.12 | 18 | 14.98 | 2147 | 579 | 2.36 / 47.23 | 2 | 4 |
6 | 13 | 1142.52 | 18 | 15.05 | 1641 | 445 | 2.80 / 47.67 | 2 | 6 |
7 | 13 | 753.72 | 18 | 15.11 | 1230 | 335 | 3.14 / 48.01 | 2 | 9 |
8 | 13 | 408.32 | 18 | 15.18 | 818 | 224 | 3.36 / 48.23 | 2 | 7 |
9 | 13 | 101.24 | 18 | 15.28 | 410 | 113 | 3.47 / 48.34 | 2 | 7 |
10 | 8 | 0.04 | 165 | 15.26 | 270 | 680 | 4.15 / 49.02 | 2 | 16 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 34 | 15.25 | 411 | 213 | 0.21 / 40.97 | 2 | 2 |
2 | 10 | 1015.60 | 4 | 15.22 | 1560 | 95 | 0.31 / 41.06 | 2 | 2 |
3 | 3 | 1090.56 | 3 | 15.25 | 1543 | 71 | 0.38 / 41.13 | 2 | 2 |
4 | 3 | 1123.28 | 4 | 15.20 | 1729 | 105 | 0.48 / 41.24 | 2 | 2 |
5 | 7 | 2007.48 | 38 | 14.92 | 2652 | 1504 | 1.99 / 42.74 | 2 | 5 |
6 | 13 | 1475.88 | 18 | 15.01 | 1994 | 539 | 2.53 / 43.28 | 2 | 4 |
7 | 13 | 968.48 | 18 | 15.09 | 1401 | 381 | 2.91 / 43.66 | 2 | 5 |
8 | 13 | 636.60 | 18 | 15.15 | 1057 | 288 | 3.19 / 43.95 | 2 | 8 |
9 | 13 | 204.96 | 18 | 15.26 | 548 | 151 | 3.35 / 44.10 | 2 | 7 |
10 | 13 | 34.60 | 18 | 15.30 | 325 | 90 | 3.43 / 44.19 | 2 | 7 |
11 | 8 | 0.20 | 165 | 15.27 | 271 | 683 | 4.12 / 44.87 | 2 | 18 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 31 | 15.26 | 406 | 192 | 0.19 / 35.97 | 2 | 2 |
2 | 3 | 1041.40 | 1 | 15.30 | 1526 | 23 | 0.22 / 36.00 | 2 | 2 |
3 | 3 | 1031.12 | 1 | 15.32 | 1592 | 24 | 0.24 / 36.02 | 2 | 2 |
4 | 5 | 1300.20 | 8 | 15.23 | 1850 | 225 | 0.47 / 36.25 | 2 | 2 |
5 | 5 | 1385.76 | 11 | 15.16 | 2075 | 346 | 0.81 / 36.59 | 2 | 2 |
6 | 5 | 1334.28 | 9 | 15.19 | 1953 | 267 | 1.08 / 36.86 | 2 | 2 |
7 | 5 | 1316.36 | 9 | 15.19 | 2058 | 281 | 1.36 / 37.14 | 2 | 2 |
8 | 7 | 2009.48 | 38 | 14.93 | 2686 | 1524 | 2.88 / 38.67 | 2 | 4 |
9 | 13 | 1447.88 | 18 | 15.01 | 1980 | 535 | 3.42 / 39.20 | 2 | 4 |
10 | 13 | 927.96 | 18 | 15.09 | 1406 | 382 | 3.80 / 39.58 | 2 | 6 |
11 | 13 | 498.72 | 18 | 15.18 | 946 | 258 | 4.06 / 39.84 | 2 | 10 |
12 | 13 | 171.64 | 18 | 15.27 | 518 | 142 | 4.20 / 39.98 | 2 | 8 |
13 | 13 | 18.12 | 18 | 15.31 | 300 | 83 | 4.28 / 40.07 | 2 | 7 |
14 | 8 | 0.08 | 165 | 15.28 | 272 | 686 | 4.97 / 40.75 | 2 | 17 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 31 | 15.28 | 400 | 189 | 0.19 / 32.23 | 2 | 2 |
2 | 7 | 2013.76 | 38 | 14.95 | 2615 | 1486 | 1.68 / 33.72 | 2 | 3 |
3 | 13 | 1418.88 | 18 | 15.04 | 1978 | 535 | 2.21 / 34.25 | 2 | 5 |
4 | 13 | 896.92 | 18 | 15.13 | 1349 | 367 | 2.58 / 34.62 | 2 | 6 |
5 | 13 | 524.00 | 18 | 15.19 | 955 | 261 | 2.84 / 34.88 | 2 | 7 |
6 | 13 | 141.84 | 18 | 15.29 | 478 | 132 | 2.97 / 35.01 | 2 | 7 |
7 | 13 | 24.40 | 18 | 15.32 | 313 | 86 | 3.06 / 35.10 | 2 | 7 |
8 | 8 | 0.12 | 165 | 15.29 | 270 | 681 | 3.74 / 35.78 | 2 | 12 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 42 | 15.26 | 395 | 253 | 0.25 / 27.83 | 2 | 2 |
2 | 3 | 667.04 | -6 | 15.63 | 0 | 0 | 0.00 / 27.83 | 2 | 2 |
3 | 3 | 857.64 | -3 | 15.63 | 0 | 0 | 0.00 / 27.83 | 2 | 2 |
4 | 7 | 2011.32 | 74 | 14.81 | 2681 | 2938 | 3.19 / 30.77 | 2 | 6 |
5 | 13 | 692.32 | 18 | 15.16 | 1105 | 302 | 3.49 / 31.07 | 2 | 7 |
6 | 13 | 327.08 | 18 | 15.24 | 703 | 193 | 3.69 / 31.26 | 2 | 7 |
7 | 13 | 57.32 | 18 | 15.31 | 358 | 99 | 3.78 / 31.36 | 2 | 6 |
8 | 8 | 0.04 | 165 | 15.29 | 271 | 684 | 4.47 / 32.04 | 2 | 14 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 33 | 15.27 | 405 | 204 | 0.20 / 22.56 | 2 | 2 |
2 | 3 | 1094.28 | 3 | 15.24 | 1682 | 77 | 0.28 / 22.63 | 2 | 2 |
3 | 3 | 1146.88 | 4 | 15.26 | 1588 | 97 | 0.38 / 22.73 | 2 | 2 |
4 | 5 | 1366.48 | 10 | 15.18 | 1944 | 295 | 0.67 / 23.03 | 2 | 2 |
5 | 5 | 1308.48 | 9 | 15.17 | 1984 | 271 | 0.94 / 23.30 | 2 | 2 |
6 | 7 | 2004.96 | 74 | 14.83 | 2609 | 2863 | 3.81 / 26.16 | 2 | 7 |
7 | 13 | 807.60 | 18 | 15.14 | 1242 | 338 | 4.15 / 26.50 | 2 | 7 |
8 | 13 | 375.08 | 18 | 15.23 | 755 | 207 | 4.35 / 26.71 | 2 | 6 |
9 | 13 | 105.80 | 18 | 15.30 | 418 | 115 | 4.47 / 26.82 | 2 | 7 |
10 | 13 | 25.72 | 18 | 15.32 | 307 | 85 | 4.55 / 26.91 | 2 | 8 |
11 | 8 | 0.04 | 165 | 15.29 | 266 | 671 | 5.22 / 27.58 | 3 | 16 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 30 | 15.28 | 403 | 185 | 0.18 / 18.13 | 2 | 2 |
2 | 10 | 1059.48 | 3 | 15.25 | 1657 | 76 | 0.26 / 18.20 | 2 | 2 |
3 | 3 | 1057.76 | 2 | 15.31 | 1535 | 47 | 0.31 / 18.25 | 2 | 2 |
4 | 7 | 2010.24 | 74 | 14.84 | 2623 | 2880 | 3.19 / 21.13 | 2 | 7 |
5 | 13 | 599.64 | 18 | 15.18 | 999 | 273 | 3.46 / 21.40 | 2 | 7 |
6 | 13 | 324.20 | 18 | 15.24 | 690 | 189 | 3.65 / 21.59 | 2 | 7 |
7 | 13 | 86.56 | 18 | 15.31 | 386 | 106 | 3.76 / 21.70 | 2 | 7 |
8 | 8 | 0.00 | 165 | 15.29 | 259 | 653 | 4.41 / 22.35 | 2 | 16 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 50 | 15.28 | 384 | 293 | 0.29 / 13.90 | 2 | 2 |
2 | 3 | 421.88 | -11 | 15.64 | 0 | 0 | 0.00 / 13.90 | 2 | 2 |
3 | 3 | 925.56 | -1 | 15.66 | 0 | 0 | 0.00 / 13.90 | 2 | 2 |
4 | 5 | 1355.96 | 10 | 15.21 | 1893 | 288 | 0.58 / 14.19 | 2 | 2 |
5 | 5 | 1384.72 | 11 | 15.15 | 2034 | 339 | 0.92 / 14.53 | 2 | 2 |
6 | 7 | 1519.52 | 74 | 15.01 | 2018 | 2241 | 3.16 / 16.77 | 2 | 6 |
7 | 13 | 534.24 | 18 | 15.23 | 910 | 249 | 3.41 / 17.02 | 2 | 8 |
8 | 13 | 271.88 | 18 | 15.29 | 614 | 169 | 3.58 / 17.19 | 2 | 6 |
9 | 13 | 63.96 | 18 | 15.34 | 334 | 92 | 3.67 / 17.28 | 2 | 6 |
10 | 8 | 0.12 | 165 | 15.31 | 262 | 662 | 4.33 / 17.94 | 2 | 12 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 53 | 15.30 | 374 | 303 | 0.30 / 9.24 | 2 | 2 |
2 | 3 | 488.92 | -10 | 15.64 | 1 | 0 | 0.00 / 9.24 | 2 | 2 |
3 | 3 | 951.56 | -1 | 15.66 | 0 | 0 | 0.00 / 9.24 | 2 | 2 |
4 | 5 | 1411.68 | 12 | 15.19 | 2101 | 383 | 0.69 / 9.62 | 2 | 2 |
5 | 5 | 1324.92 | 9 | 15.18 | 1965 | 268 | 0.95 / 9.89 | 2 | 2 |
6 | 5 | 1378.28 | 11 | 15.19 | 1912 | 319 | 1.27 / 10.21 | 2 | 3 |
7 | 7 | 1506.32 | 74 | 15.00 | 2040 | 2264 | 3.54 / 12.48 | 2 | 7 |
8 | 13 | 649.36 | 18 | 15.20 | 1045 | 286 | 3.82 / 12.76 | 2 | 6 |
9 | 13 | 239.36 | 18 | 15.29 | 583 | 160 | 3.98 / 12.92 | 2 | 7 |
10 | 13 | 65.40 | 18 | 15.33 | 337 | 93 | 4.08 / 13.01 | 2 | 6 |
11 | 8 | 0.12 | 165 | 15.32 | 235 | 594 | 4.67 / 13.61 | 2 | 14 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 32 | 15.32 | 365 | 179 | 0.18 / 4.71 | 2 | 2 |
2 | 10 | 1068.52 | 3 | 15.29 | 1526 | 70 | 0.25 / 4.78 | 2 | 2 |
3 | 10 | 1114.20 | 3 | 15.30 | 1581 | 73 | 0.32 / 4.85 | 2 | 2 |
4 | 3 | 1340.36 | 10 | 15.16 | 1963 | 298 | 0.62 / 5.15 | 2 | 2 |
5 | 3 | 1210.24 | 6 | 15.27 | 1695 | 155 | 0.77 / 5.31 | 2 | 2 |
6 | 5 | 1332.36 | 9 | 15.25 | 1843 | 253 | 1.03 / 5.56 | 2 | 2 |
7 | 7 | 1507.40 | 75 | 15.02 | 2002 | 2255 | 3.28 / 7.82 | 2 | 5 |
8 | 13 | 652.32 | 18 | 15.22 | 1046 | 287 | 3.57 / 8.10 | 2 | 6 |
9 | 13 | 219.12 | 18 | 15.30 | 554 | 153 | 3.72 / 8.26 | 2 | 7 |
10 | 13 | 57.80 | 18 | 15.35 | 324 | 90 | 3.81 / 8.34 | 2 | 6 |
11 | 8 | 0.12 | 165 | 15.33 | 234 | 592 | 4.40 / 8.94 | 2 | 14 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 27 | 15.51 | 332 | 139 | 0.14 / 1.44 | 2 | 3 |
2 | 10 | 1069.24 | 4 | 15.37 | 1494 | 92 | 0.23 / 1.53 | 2 | 2 |
3 | 3 | 1108.28 | 3 | 15.29 | 1648 | 76 | 0.31 / 1.60 | 2 | 2 |
4 | 3 | 1150.96 | 4 | 15.32 | 1476 | 90 | 0.40 / 1.70 | 2 | 2 |
5 | 7 | 1332.12 | 74 | 15.05 | 1794 | 1998 | 2.39 / 3.69 | 2 | 5 |
6 | 13 | 238.36 | 18 | 15.32 | 571 | 157 | 2.55 / 3.85 | 2 | 6 |
7 | 13 | 59.32 | 18 | 15.35 | 328 | 91 | 2.64 / 3.94 | 2 | 6 |
8 | 8 | 0.04 | 165 | 15.33 | 234 | 592 | 3.23 / 4.53 | 2 | 14 |
Average= | 2.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 27 | 15.65 | 347 | 147 | 0.15 / 0.15 | 2 | 3 |
2 | 7 | 121.36 | 74 | 15.61 | 370 | 427 | 0.57 / 0.57 | 2 | 3 |
3 | 8 | 0.08 | 240 | 15.56 | 194 | 724 | 1.30 / 1.30 | 3 | 17 |
Average= | 1.30 (KJ/cycle) |