SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 31 | 15.23 | 437 | 206 | 0.21 / 88.58 | 2 | 2 |
2 | 7 | 2012.32 | 38 | 14.96 | 2954 | 1679 | 1.89 / 90.26 | 2 | 4 |
3 | 13 | 1361.68 | 18 | 15.03 | 2145 | 580 | 2.47 / 90.84 | 2 | 8 |
4 | 13 | 906.20 | 18 | 15.10 | 1545 | 420 | 2.89 / 91.26 | 2 | 11 |
5 | 13 | 328.52 | 18 | 15.24 | 755 | 207 | 3.09 / 91.46 | 2 | 11 |
6 | 8 | 0.20 | 165 | 15.26 | 284 | 715 | 3.81 / 92.18 | 2 | 17 |
Average= | 4.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 31 | 15.22 | 458 | 216 | 0.22 / 84.69 | 2 | 2 |
2 | 3 | 975.88 | -1 | 15.62 | 1 | 0 | 0.00 / 84.69 | 2 | 2 |
3 | 3 | 1020.24 | 1 | 15.34 | 1732 | 27 | 0.24 / 84.72 | 2 | 2 |
4 | 7 | 2004.52 | 38 | 14.96 | 2950 | 1677 | 1.92 / 86.40 | 2 | 5 |
5 | 13 | 1348.76 | 18 | 15.05 | 2122 | 575 | 2.49 / 86.97 | 2 | 7 |
6 | 13 | 810.80 | 18 | 15.14 | 1420 | 387 | 2.88 / 87.36 | 2 | 10 |
7 | 13 | 321.60 | 18 | 15.26 | 745 | 205 | 3.09 / 87.56 | 2 | 11 |
8 | 13 | 26.88 | 18 | 15.31 | 334 | 92 | 3.18 / 87.66 | 2 | 8 |
9 | 8 | 0.32 | 165 | 15.27 | 283 | 713 | 3.89 / 88.37 | 2 | 14 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 30 | 14.84 | 439 | 195 | 0.20 / 80.73 | 2 | 2 |
2 | 10 | 1016.76 | 2 | 15.10 | 1759 | 53 | 0.25 / 80.79 | 2 | 3 |
3 | 7 | 1981.56 | 38 | 14.98 | 2898 | 1650 | 1.90 / 82.44 | 2 | 5 |
4 | 13 | 1386.28 | 18 | 15.07 | 2068 | 561 | 2.46 / 83.00 | 2 | 4 |
5 | 13 | 993.76 | 18 | 15.12 | 1543 | 420 | 2.88 / 83.42 | 2 | 8 |
6 | 13 | 466.84 | 18 | 15.24 | 920 | 252 | 3.13 / 83.67 | 2 | 11 |
7 | 13 | 55.84 | 18 | 15.31 | 375 | 103 | 3.23 / 83.77 | 2 | 8 |
8 | 8 | 0.24 | 165 | 15.28 | 280 | 706 | 3.94 / 84.48 | 2 | 19 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 30 | 15.23 | 424 | 194 | 0.19 / 60.10 | 2 | 2 |
2 | 7 | 1697.72 | 38 | 15.05 | 2580 | 1476 | 1.67 / 61.58 | 2 | 5 |
3 | 13 | 1697.04 | 18 | 15.02 | 2600 | 703 | 2.37 / 62.28 | 2 | 8 |
4 | 13 | 1697.12 | 18 | 14.96 | 2595 | 699 | 3.07 / 62.98 | 2 | 10 |
5 | 13 | 1697.00 | 18 | 14.91 | 2586 | 694 | 3.76 / 63.67 | 2 | 10 |
6 | 13 | 1697.08 | 18 | 14.84 | 2592 | 692 | 4.46 / 64.36 | 2 | 11 |
7 | 13 | 1697.00 | 18 | 14.80 | 2592 | 691 | 5.15 / 65.05 | 2 | 14 |
8 | 13 | 1697.00 | 18 | 14.74 | 2572 | 682 | 5.83 / 65.74 | 2 | 13 |
9 | 13 | 1697.08 | 18 | 14.69 | 2579 | 682 | 6.51 / 66.42 | 2 | 16 |
10 | 13 | 1697.16 | 18 | 14.63 | 2573 | 678 | 7.19 / 67.10 | 3 | 19 |
11 | 13 | 1697.08 | 18 | 14.60 | 2572 | 676 | 7.87 / 67.77 | 3 | 19 |
12 | 13 | 1697.08 | 18 | 14.56 | 2570 | 674 | 8.54 / 68.45 | 3 | 19 |
13 | 13 | 1697.12 | 18 | 14.52 | 2576 | 673 | 9.21 / 69.12 | 4 | 20 |
14 | 13 | 1697.08 | 18 | 14.50 | 2574 | 672 | 9.88 / 69.79 | 4 | 21 |
15 | 13 | 1697.08 | 18 | 14.46 | 2564 | 667 | 10.55 / 70.46 | 4 | 21 |
16 | 13 | 1697.00 | 18 | 14.44 | 2566 | 667 | 11.22 / 71.13 | 4 | 21 |
17 | 13 | 1697.16 | 18 | 14.41 | 2575 | 668 | 11.89 / 71.79 | 5 | 22 |
18 | 13 | 1697.04 | 18 | 14.39 | 2572 | 666 | 12.55 / 72.46 | 5 | 24 |
19 | 13 | 1697.04 | 18 | 14.37 | 2573 | 666 | 13.22 / 73.12 | 8 | 28 |
20 | 13 | 1697.00 | 18 | 14.34 | 2570 | 663 | 13.88 / 73.79 | 8 | 26 |
21 | 13 | 1697.04 | 18 | 14.32 | 2569 | 662 | 14.54 / 74.45 | 8 | 26 |
22 | 13 | 1697.08 | 18 | 14.30 | 2557 | 658 | 15.20 / 75.11 | 9 | 29 |
23 | 13 | 1697.12 | 18 | 14.30 | 2571 | 662 | 15.86 / 75.77 | 11 | 34 |
24 | 13 | 1697.08 | 18 | 14.27 | 2569 | 660 | 16.52 / 76.43 | 14 | 39 |
25 | 13 | 1697.16 | 18 | 14.25 | 2566 | 658 | 17.18 / 77.09 | 19 | 52 |
26 | 13 | 1697.04 | 18 | 14.22 | 2559 | 655 | 17.84 / 77.74 | 30 | 152 |
27 | 13 | 1697.16 | 18 | 14.25 | 2309 | 592 | 18.43 / 78.34 | 76 | 250 |
28 | 13 | 1697.08 | 18 | 14.34 | 1819 | 470 | 18.90 / 78.81 | 250 | 250 |
29 | 13 | 1697.04 | 18 | 14.63 | 528 | 139 | 19.04 / 78.94 | 250 | 250 |
30 | 13 | 1697.00 | 18 | 14.73 | 260 | 69 | 19.11 / 79.01 | 250 | 250 |
31 | 13 | 1697.08 | 18 | 14.70 | 500 | 132 | 19.24 / 79.15 | 250 | 250 |
32 | 13 | 1697.12 | 18 | 14.70 | 454 | 120 | 19.36 / 79.27 | 250 | 250 |
33 | 13 | 1697.04 | 18 | 14.77 | 297 | 79 | 19.44 / 79.34 | 250 | 250 |
34 | 13 | 1697.00 | 18 | 14.79 | 275 | 73 | 19.51 / 79.42 | 250 | 250 |
35 | 13 | 1696.96 | 18 | 14.79 | 332 | 88 | 19.60 / 79.51 | 250 | 250 |
36 | 13 | 1697.20 | 18 | 14.78 | 394 | 105 | 19.70 / 79.61 | 250 | 250 |
37 | 13 | 1697.00 | 18 | 14.82 | 280 | 75 | 19.78 / 79.69 | 250 | 250 |
38 | 13 | 1697.04 | 18 | 14.83 | 277 | 74 | 19.85 / 79.76 | 250 | 250 |
39 | 13 | 1697.12 | 18 | 14.83 | 305 | 81 | 19.93 / 79.84 | 250 | 250 |
40 | 13 | 1697.00 | 18 | 14.84 | 282 | 75 | 20.01 / 79.92 | 250 | 250 |
41 | 8 | -0.40 | 165 | 14.88 | 253 | 621 | 20.63 / 80.54 | 249 | 249 |
Average= | 4.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 30 | 15.23 | 431 | 197 | 0.20 / 56.17 | 2 | 2 |
2 | 7 | 2006.04 | 38 | 14.97 | 2973 | 1691 | 1.89 / 57.86 | 2 | 5 |
3 | 13 | 1402.64 | 18 | 15.06 | 2220 | 602 | 2.49 / 58.46 | 2 | 9 |
4 | 13 | 805.88 | 18 | 15.18 | 1435 | 392 | 2.88 / 58.86 | 2 | 10 |
5 | 13 | 327.88 | 18 | 15.28 | 773 | 213 | 3.09 / 59.07 | 2 | 11 |
6 | 13 | 40.00 | 18 | 15.33 | 361 | 100 | 3.19 / 59.17 | 2 | 11 |
7 | 8 | 0.12 | 165 | 15.28 | 293 | 739 | 3.93 / 59.91 | 2 | 25 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 30 | 15.23 | 448 | 205 | 0.20 / 52.25 | 2 | 2 |
2 | 7 | 2008.92 | 38 | 14.96 | 2974 | 1691 | 1.90 / 53.94 | 2 | 5 |
3 | 13 | 1353.84 | 18 | 15.05 | 2156 | 584 | 2.48 / 54.52 | 2 | 8 |
4 | 13 | 776.84 | 18 | 15.17 | 1393 | 380 | 2.86 / 54.90 | 2 | 10 |
5 | 13 | 342.36 | 18 | 15.27 | 797 | 219 | 3.08 / 55.12 | 2 | 10 |
6 | 13 | 37.60 | 18 | 15.32 | 363 | 100 | 3.18 / 55.22 | 2 | 6 |
7 | 8 | -0.04 | 165 | 15.28 | 298 | 751 | 3.93 / 55.97 | 5 | 19 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 30 | 15.23 | 440 | 201 | 0.20 / 48.29 | 2 | 2 |
2 | 7 | 2006.20 | 39 | 14.97 | 2970 | 1734 | 1.94 / 50.03 | 2 | 5 |
3 | 13 | 1248.36 | 18 | 15.08 | 2010 | 546 | 2.48 / 50.57 | 2 | 8 |
4 | 13 | 784.92 | 18 | 15.17 | 1409 | 385 | 2.87 / 50.96 | 2 | 11 |
5 | 13 | 399.88 | 18 | 15.25 | 881 | 242 | 3.11 / 51.20 | 2 | 11 |
6 | 13 | 39.68 | 18 | 15.31 | 364 | 100 | 3.21 / 51.30 | 2 | 10 |
7 | 8 | 0.00 | 165 | 15.27 | 295 | 743 | 3.95 / 52.04 | 2 | 16 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 30 | 15.23 | 427 | 195 | 0.20 / 44.36 | 2 | 2 |
2 | 7 | 2006.72 | 38 | 14.97 | 2968 | 1688 | 1.88 / 46.05 | 2 | 5 |
3 | 13 | 1368.56 | 18 | 15.06 | 2173 | 589 | 2.47 / 46.64 | 2 | 7 |
4 | 13 | 810.40 | 18 | 15.17 | 1436 | 392 | 2.86 / 47.03 | 2 | 10 |
5 | 13 | 379.16 | 18 | 15.26 | 844 | 232 | 3.10 / 47.27 | 2 | 11 |
6 | 13 | 39.64 | 18 | 15.32 | 356 | 98 | 3.19 / 47.36 | 2 | 11 |
7 | 8 | 0.16 | 165 | 15.28 | 289 | 729 | 3.92 / 48.09 | 2 | 20 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 30 | 15.24 | 418 | 191 | 0.19 / 40.42 | 2 | 2 |
2 | 7 | 2006.24 | 38 | 14.97 | 2967 | 1688 | 1.88 / 42.11 | 2 | 5 |
3 | 13 | 1434.04 | 18 | 15.05 | 2257 | 611 | 2.49 / 42.72 | 2 | 7 |
4 | 13 | 867.76 | 18 | 15.14 | 1512 | 412 | 2.90 / 43.14 | 2 | 10 |
5 | 13 | 373.32 | 18 | 15.27 | 833 | 229 | 3.13 / 43.36 | 2 | 10 |
6 | 13 | 23.72 | 18 | 15.33 | 331 | 91 | 3.22 / 43.46 | 2 | 6 |
7 | 8 | 0.08 | 165 | 15.28 | 283 | 713 | 3.94 / 44.17 | 2 | 16 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 30 | 15.23 | 428 | 196 | 0.20 / 36.52 | 2 | 2 |
2 | 7 | 2014.40 | 38 | 14.98 | 2976 | 1694 | 1.89 / 38.21 | 2 | 5 |
3 | 13 | 1369.92 | 18 | 15.08 | 2181 | 592 | 2.48 / 38.80 | 2 | 8 |
4 | 13 | 785.28 | 18 | 15.18 | 1400 | 383 | 2.86 / 39.19 | 2 | 10 |
5 | 13 | 392.40 | 18 | 15.27 | 860 | 236 | 3.10 / 39.42 | 2 | 11 |
6 | 13 | 27.24 | 18 | 15.33 | 333 | 92 | 3.19 / 39.51 | 2 | 9 |
7 | 8 | 0.08 | 165 | 15.29 | 285 | 719 | 3.91 / 40.23 | 2 | 18 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 30 | 15.25 | 445 | 204 | 0.20 / 32.60 | 2 | 2 |
2 | 7 | 2010.20 | 38 | 14.98 | 2966 | 1688 | 1.89 / 34.28 | 2 | 4 |
3 | 13 | 1458.96 | 18 | 15.05 | 2285 | 619 | 2.51 / 34.90 | 2 | 7 |
4 | 13 | 855.96 | 18 | 15.16 | 1496 | 408 | 2.92 / 35.31 | 2 | 11 |
5 | 13 | 316.24 | 18 | 15.28 | 746 | 205 | 3.12 / 35.52 | 2 | 9 |
6 | 13 | 25.84 | 18 | 15.33 | 329 | 91 | 3.22 / 35.61 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.29 | 283 | 714 | 3.93 / 36.32 | 2 | 12 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 30 | 15.24 | 447 | 204 | 0.20 / 28.66 | 2 | 2 |
2 | 7 | 2013.08 | 38 | 14.98 | 2972 | 1692 | 1.90 / 30.35 | 2 | 4 |
3 | 13 | 1385.36 | 18 | 15.07 | 2194 | 595 | 2.49 / 30.94 | 2 | 9 |
4 | 13 | 873.08 | 18 | 15.15 | 1519 | 414 | 2.91 / 31.36 | 2 | 11 |
5 | 13 | 368.60 | 18 | 15.27 | 828 | 228 | 3.13 / 31.58 | 2 | 11 |
6 | 13 | 20.04 | 18 | 15.34 | 324 | 89 | 3.22 / 31.67 | 2 | 14 |
7 | 8 | 0.12 | 165 | 15.30 | 285 | 719 | 3.94 / 32.39 | 2 | 15 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.36 | 30 | 15.24 | 437 | 200 | 0.20 / 24.80 | 2 | 2 |
2 | 7 | 2009.48 | 38 | 14.99 | 2970 | 1692 | 1.89 / 26.49 | 2 | 4 |
3 | 13 | 1296.24 | 18 | 15.10 | 2067 | 562 | 2.45 / 27.05 | 2 | 8 |
4 | 13 | 848.96 | 18 | 15.17 | 1484 | 405 | 2.86 / 27.45 | 2 | 10 |
5 | 13 | 301.60 | 18 | 15.31 | 723 | 199 | 3.06 / 27.65 | 2 | 10 |
6 | 13 | 22.12 | 18 | 15.35 | 318 | 88 | 3.15 / 27.74 | 2 | 7 |
7 | 8 | 0.12 | 165 | 15.30 | 281 | 709 | 3.86 / 28.45 | 2 | 21 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 29 | 15.26 | 414 | 183 | 0.18 / 20.23 | 2 | 2 |
2 | 3 | 1032.32 | 1 | 15.34 | 1778 | 27 | 0.21 / 20.25 | 2 | 4 |
3 | 7 | 2008.12 | 74 | 14.86 | 2949 | 3243 | 3.45 / 23.50 | 2 | 7 |
4 | 13 | 531.88 | 18 | 15.24 | 1048 | 287 | 3.74 / 23.78 | 2 | 10 |
5 | 13 | 53.88 | 18 | 15.34 | 367 | 101 | 3.84 / 23.88 | 2 | 8 |
6 | 8 | -0.16 | 165 | 15.29 | 282 | 711 | 4.55 / 24.60 | 2 | 15 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 31 | 15.27 | 433 | 205 | 0.20 / 15.72 | 2 | 2 |
2 | 3 | 933.64 | -1 | 15.70 | 0 | 0 | 0.00 / 15.72 | 2 | 2 |
3 | 3 | 971.88 | -1 | 15.73 | 0 | 0 | 0.00 / 15.72 | 2 | 2 |
4 | 7 | 2011.32 | 74 | 14.86 | 2952 | 3246 | 3.45 / 18.97 | 2 | 8 |
5 | 13 | 520.40 | 18 | 15.24 | 1029 | 282 | 3.73 / 19.25 | 2 | 9 |
6 | 13 | 50.04 | 18 | 15.34 | 351 | 97 | 3.83 / 19.35 | 2 | 10 |
7 | 8 | 0.20 | 165 | 15.30 | 276 | 697 | 4.53 / 20.04 | 2 | 18 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 28 | 15.27 | 436 | 186 | 0.19 / 11.91 | 2 | 2 |
2 | 7 | 1507.72 | 74 | 15.05 | 2316 | 2579 | 2.77 / 14.49 | 2 | 7 |
3 | 13 | 414.80 | 18 | 15.30 | 859 | 237 | 3.00 / 14.72 | 2 | 10 |
4 | 13 | 18.56 | 18 | 15.36 | 308 | 85 | 3.09 / 14.81 | 2 | 6 |
5 | 8 | 0.20 | 165 | 15.32 | 279 | 705 | 3.79 / 15.51 | 2 | 16 |
Average= | 3.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 28 | 15.27 | 442 | 189 | 0.19 / 8.09 | 2 | 2 |
2 | 7 | 1520.08 | 74 | 15.04 | 2324 | 2587 | 2.78 / 10.68 | 2 | 8 |
3 | 13 | 432.92 | 18 | 15.30 | 895 | 246 | 3.02 / 10.93 | 2 | 9 |
4 | 13 | 20.60 | 18 | 15.37 | 313 | 87 | 3.11 / 11.01 | 2 | 13 |
5 | 8 | 0.16 | 165 | 15.32 | 280 | 708 | 3.82 / 11.72 | 2 | 17 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 33 | 15.31 | 441 | 223 | 0.22 / 4.42 | 2 | 2 |
2 | 3 | 837.56 | -3 | 15.71 | 1 | 0 | 0.00 / 4.42 | 2 | 2 |
3 | 3 | 953.64 | -1 | 15.73 | 0 | 0 | 0.00 / 4.42 | 2 | 2 |
4 | 7 | 1524.92 | 74 | 15.04 | 2326 | 2589 | 2.81 / 7.01 | 2 | 7 |
5 | 13 | 304.72 | 18 | 15.32 | 711 | 196 | 3.01 / 7.21 | 2 | 8 |
6 | 8 | 0.24 | 165 | 15.33 | 277 | 701 | 3.71 / 7.91 | 2 | 12 |
Average= | 2.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 28 | 15.47 | 395 | 171 | 0.17 / 1.66 | 2 | 3 |
2 | 7 | 982.16 | 74 | 15.23 | 1623 | 1829 | 2.00 / 3.49 | 2 | 11 |
3 | 8 | 0.08 | 165 | 15.39 | 280 | 711 | 2.71 / 4.20 | 2 | 14 |
Average= | 2.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 86.20 | 28 | 15.62 | 361 | 158 | 0.16 / 0.16 | 2 | 3 |
2 | 7 | 102.24 | 74 | 15.58 | 392 | 452 | 0.61 / 0.61 | 2 | 4 |
3 | 8 | 0.28 | 240 | 15.54 | 235 | 876 | 1.49 / 1.49 | 2 | 95 |
Average= | 1.49 (KJ/cycle) |