SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 28 | 15.10 | 496 | 210 | 0.21 / 232.78 | 2 | 14 |
2 | 3 | 1019.36 | 1 | 15.12 | 1747 | 26 | 0.24 / 232.80 | 2 | 12 |
3 | 7 | 2009.28 | 38 | 14.84 | 2890 | 1630 | 1.87 / 234.43 | 2 | 11 |
4 | 13 | 1353.96 | 18 | 14.93 | 2111 | 567 | 2.43 / 235.00 | 2 | 16 |
5 | 13 | 786.08 | 18 | 15.02 | 1398 | 378 | 2.81 / 235.38 | 2 | 19 |
6 | 13 | 303.92 | 18 | 15.14 | 768 | 209 | 3.02 / 235.59 | 2 | 21 |
7 | 13 | 50.80 | 18 | 15.20 | 407 | 111 | 3.13 / 235.70 | 2 | 18 |
8 | 8 | 0.12 | 165 | 15.16 | 328 | 820 | 3.95 / 236.52 | 2 | 14 |
9 | 14 | 0.12 | 30 | 15.14 | 327 | 149 | 4.10 / 236.67 | 3 | 12 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 28 | 15.12 | 479 | 203 | 0.20 / 228.84 | 2 | 14 |
2 | 3 | 970.32 | -1 | 15.43 | 0 | 0 | 0.00 / 228.84 | 2 | 14 |
3 | 7 | 2009.28 | 38 | 14.83 | 2895 | 1631 | 1.83 / 230.47 | 2 | 11 |
4 | 13 | 1358.08 | 18 | 14.92 | 2113 | 567 | 2.40 / 231.04 | 2 | 16 |
5 | 13 | 818.64 | 18 | 15.02 | 1441 | 390 | 2.79 / 231.43 | 2 | 19 |
6 | 13 | 310.32 | 18 | 15.13 | 782 | 213 | 3.00 / 231.64 | 2 | 21 |
7 | 13 | 52.56 | 18 | 15.19 | 414 | 113 | 3.12 / 231.75 | 2 | 18 |
8 | 8 | -0.12 | 165 | 15.16 | 325 | 813 | 3.93 / 232.57 | 2 | 16 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 29 | 15.12 | 494 | 217 | 0.22 / 224.92 | 2 | 14 |
2 | 7 | 2004.64 | 38 | 14.83 | 2884 | 1625 | 1.84 / 226.54 | 2 | 12 |
3 | 13 | 1321.08 | 18 | 14.94 | 2068 | 556 | 2.40 / 227.10 | 2 | 16 |
4 | 13 | 864.68 | 18 | 15.01 | 1501 | 406 | 2.80 / 227.50 | 2 | 19 |
5 | 13 | 288.08 | 18 | 15.14 | 748 | 204 | 3.01 / 227.71 | 2 | 21 |
6 | 13 | 43.60 | 18 | 15.20 | 401 | 110 | 3.12 / 227.82 | 2 | 17 |
7 | 8 | -0.20 | 165 | 15.16 | 327 | 818 | 3.94 / 228.64 | 2 | 12 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 28 | 15.10 | 504 | 213 | 0.21 / 220.93 | 2 | 14 |
2 | 3 | 1033.08 | 1 | 15.11 | 1751 | 26 | 0.24 / 220.95 | 2 | 12 |
3 | 7 | 2009.12 | 38 | 14.84 | 2885 | 1627 | 1.87 / 222.58 | 2 | 12 |
4 | 13 | 1439.96 | 18 | 14.91 | 2222 | 596 | 2.46 / 223.18 | 2 | 15 |
5 | 13 | 843.28 | 18 | 15.02 | 1481 | 400 | 2.86 / 223.58 | 2 | 19 |
6 | 13 | 296.60 | 18 | 15.15 | 761 | 208 | 3.07 / 223.78 | 2 | 21 |
7 | 13 | 49.20 | 18 | 15.20 | 401 | 110 | 3.18 / 223.89 | 2 | 18 |
8 | 8 | 0.20 | 165 | 15.17 | 323 | 808 | 3.99 / 224.70 | 2 | 16 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 28 | 15.12 | 512 | 217 | 0.22 / 216.98 | 2 | 13 |
2 | 7 | 2007.76 | 38 | 14.83 | 2881 | 1624 | 1.84 / 218.61 | 2 | 12 |
3 | 13 | 1316.80 | 18 | 14.93 | 2072 | 557 | 2.40 / 219.16 | 2 | 16 |
4 | 13 | 839.32 | 18 | 15.02 | 1471 | 398 | 2.79 / 219.56 | 2 | 19 |
5 | 13 | 301.16 | 18 | 15.14 | 772 | 210 | 3.01 / 219.77 | 2 | 21 |
6 | 13 | 48.72 | 18 | 15.20 | 406 | 111 | 3.12 / 219.88 | 2 | 17 |
7 | 8 | 0.08 | 165 | 15.16 | 332 | 830 | 3.95 / 220.71 | 2 | 13 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 27 | 15.11 | 507 | 207 | 0.21 / 212.95 | 2 | 12 |
2 | 3 | 1033.36 | 1 | 15.10 | 1764 | 27 | 0.23 / 212.98 | 2 | 15 |
3 | 7 | 2008.32 | 38 | 14.84 | 2888 | 1629 | 1.86 / 214.61 | 2 | 12 |
4 | 13 | 1256.36 | 18 | 14.95 | 1984 | 534 | 2.40 / 215.14 | 2 | 16 |
5 | 13 | 969.76 | 18 | 14.98 | 1629 | 439 | 2.84 / 215.58 | 2 | 18 |
6 | 13 | 350.52 | 18 | 15.13 | 837 | 228 | 3.06 / 215.81 | 2 | 21 |
7 | 13 | 48.00 | 18 | 15.20 | 408 | 112 | 3.17 / 215.92 | 2 | 18 |
8 | 8 | 0.04 | 165 | 15.17 | 338 | 846 | 4.02 / 216.77 | 2 | 11 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 28 | 15.13 | 474 | 201 | 0.20 / 209.02 | 2 | 11 |
2 | 3 | 945.56 | -2 | 15.45 | 0 | 0 | 0.00 / 209.02 | 2 | 11 |
3 | 7 | 2007.72 | 38 | 14.84 | 2879 | 1624 | 1.82 / 210.64 | 2 | 11 |
4 | 13 | 1360.24 | 18 | 14.93 | 2114 | 568 | 2.39 / 211.21 | 2 | 14 |
5 | 13 | 857.80 | 18 | 15.02 | 1488 | 402 | 2.79 / 211.61 | 2 | 18 |
6 | 13 | 306.60 | 18 | 15.15 | 778 | 212 | 3.01 / 211.83 | 2 | 21 |
7 | 13 | 33.60 | 18 | 15.20 | 379 | 104 | 3.11 / 211.93 | 2 | 16 |
8 | 8 | 0.24 | 165 | 15.17 | 326 | 816 | 3.93 / 212.74 | 2 | 12 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 28 | 15.14 | 493 | 209 | 0.21 / 205.11 | 2 | 11 |
2 | 7 | 2004.12 | 38 | 14.86 | 2887 | 1630 | 1.84 / 206.74 | 2 | 12 |
3 | 13 | 1335.80 | 18 | 14.96 | 2084 | 561 | 2.40 / 207.31 | 2 | 16 |
4 | 13 | 813.72 | 18 | 15.04 | 1436 | 389 | 2.79 / 207.69 | 2 | 20 |
5 | 13 | 277.08 | 18 | 15.17 | 736 | 201 | 2.99 / 207.89 | 2 | 21 |
6 | 13 | 40.60 | 18 | 15.23 | 389 | 107 | 3.10 / 208.00 | 2 | 16 |
7 | 8 | 0.12 | 165 | 15.18 | 326 | 817 | 3.91 / 208.82 | 2 | 16 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 29 | 15.14 | 494 | 217 | 0.22 / 201.16 | 2 | 11 |
2 | 7 | 2004.56 | 38 | 14.85 | 2877 | 1623 | 1.84 / 202.78 | 2 | 12 |
3 | 13 | 1311.56 | 18 | 14.96 | 2062 | 555 | 2.40 / 203.34 | 2 | 15 |
4 | 13 | 878.72 | 18 | 15.03 | 1528 | 413 | 2.81 / 203.75 | 2 | 19 |
5 | 13 | 375.32 | 18 | 15.14 | 866 | 236 | 3.05 / 203.99 | 2 | 21 |
6 | 13 | 42.36 | 18 | 15.23 | 397 | 109 | 3.15 / 204.10 | 2 | 18 |
7 | 8 | 0.12 | 165 | 15.18 | 323 | 809 | 3.96 / 204.90 | 2 | 19 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 27 | 15.12 | 492 | 201 | 0.20 / 197.17 | 2 | 10 |
2 | 10 | 1022.64 | 2 | 15.09 | 1746 | 53 | 0.25 / 197.22 | 2 | 13 |
3 | 7 | 2006.68 | 38 | 14.86 | 2878 | 1625 | 1.88 / 198.85 | 2 | 13 |
4 | 13 | 1369.52 | 18 | 14.96 | 2125 | 572 | 2.45 / 199.42 | 2 | 16 |
5 | 13 | 840.04 | 18 | 15.03 | 1462 | 396 | 2.85 / 199.81 | 2 | 18 |
6 | 13 | 297.08 | 18 | 15.16 | 763 | 208 | 3.05 / 200.02 | 2 | 22 |
7 | 13 | 35.16 | 18 | 15.23 | 386 | 106 | 3.16 / 200.13 | 2 | 16 |
8 | 8 | 0.04 | 165 | 15.18 | 325 | 814 | 3.97 / 200.94 | 2 | 19 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 27 | 15.13 | 474 | 194 | 0.19 / 193.30 | 2 | 12 |
2 | 7 | 2009.52 | 38 | 14.85 | 2873 | 1621 | 1.81 / 194.92 | 2 | 11 |
3 | 13 | 1299.20 | 18 | 14.97 | 2033 | 548 | 2.36 / 195.47 | 2 | 16 |
4 | 13 | 825.80 | 18 | 15.05 | 1445 | 391 | 2.75 / 195.86 | 2 | 19 |
5 | 13 | 280.88 | 18 | 15.17 | 733 | 200 | 2.95 / 196.06 | 2 | 21 |
6 | 13 | 26.08 | 18 | 15.23 | 367 | 101 | 3.05 / 196.16 | 2 | 15 |
7 | 8 | 0.12 | 165 | 15.18 | 321 | 804 | 3.86 / 196.97 | 2 | 17 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 29 | 15.13 | 483 | 212 | 0.21 / 189.36 | 2 | 12 |
2 | 3 | 943.80 | -2 | 15.46 | 0 | 0 | 0.00 / 189.36 | 2 | 12 |
3 | 7 | 2005.96 | 38 | 14.85 | 2890 | 1631 | 1.84 / 190.99 | 2 | 11 |
4 | 13 | 1384.08 | 18 | 14.95 | 2149 | 578 | 2.42 / 191.57 | 2 | 15 |
5 | 13 | 837.92 | 18 | 15.04 | 1468 | 397 | 2.82 / 191.96 | 2 | 19 |
6 | 13 | 342.52 | 18 | 15.15 | 820 | 224 | 3.04 / 192.19 | 2 | 21 |
7 | 13 | 29.28 | 18 | 15.23 | 372 | 102 | 3.14 / 192.29 | 2 | 15 |
8 | 8 | 0.32 | 165 | 15.18 | 327 | 819 | 3.96 / 193.11 | 2 | 17 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.16 | 28 | 15.13 | 504 | 214 | 0.21 / 185.46 | 2 | 12 |
2 | 7 | 2003.92 | 38 | 14.85 | 2888 | 1630 | 1.84 / 187.09 | 2 | 11 |
3 | 13 | 1279.12 | 18 | 14.97 | 2019 | 544 | 2.39 / 187.63 | 2 | 16 |
4 | 13 | 812.64 | 18 | 15.05 | 1431 | 388 | 2.77 / 188.02 | 2 | 19 |
5 | 13 | 259.44 | 18 | 15.17 | 706 | 193 | 2.97 / 188.21 | 2 | 21 |
6 | 13 | 28.24 | 18 | 15.22 | 382 | 105 | 3.07 / 188.32 | 2 | 15 |
7 | 8 | 0.04 | 165 | 15.18 | 331 | 829 | 3.90 / 189.15 | 2 | 15 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 28 | 15.14 | 498 | 211 | 0.21 / 181.52 | 2 | 13 |
2 | 7 | 2009.84 | 38 | 14.85 | 2892 | 1632 | 1.84 / 183.15 | 2 | 11 |
3 | 13 | 1301.80 | 18 | 14.96 | 2050 | 552 | 2.40 / 183.71 | 2 | 16 |
4 | 13 | 830.88 | 18 | 15.04 | 1450 | 393 | 2.79 / 184.10 | 2 | 18 |
5 | 13 | 353.92 | 18 | 15.15 | 836 | 228 | 3.02 / 184.33 | 2 | 21 |
6 | 13 | 21.84 | 18 | 15.23 | 364 | 100 | 3.12 / 184.43 | 2 | 15 |
7 | 8 | 0.00 | 165 | 15.19 | 326 | 817 | 3.93 / 185.24 | 2 | 15 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 28 | 15.13 | 507 | 215 | 0.21 / 177.51 | 2 | 14 |
2 | 10 | 1001.00 | 2 | 15.09 | 1718 | 52 | 0.27 / 177.56 | 2 | 14 |
3 | 3 | 975.00 | -1 | 15.46 | 0 | 0 | 0.05 / 177.56 | 2 | 14 |
4 | 7 | 2009.08 | 38 | 14.87 | 2880 | 1627 | 1.89 / 179.19 | 2 | 12 |
5 | 13 | 1408.72 | 18 | 14.95 | 2168 | 583 | 2.48 / 179.77 | 2 | 16 |
6 | 13 | 822.44 | 18 | 15.05 | 1441 | 390 | 2.87 / 180.16 | 2 | 19 |
7 | 13 | 333.56 | 18 | 15.16 | 814 | 222 | 3.09 / 180.39 | 2 | 21 |
8 | 13 | 20.80 | 18 | 15.25 | 366 | 100 | 3.19 / 180.49 | 2 | 12 |
9 | 8 | 0.20 | 165 | 15.20 | 329 | 825 | 4.02 / 181.31 | 2 | 14 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 29 | 15.14 | 469 | 206 | 0.21 / 173.62 | 2 | 15 |
2 | 3 | 930.88 | -2 | 15.46 | 0 | 0 | 0.00 / 173.62 | 2 | 15 |
3 | 7 | 2007.80 | 38 | 14.86 | 2873 | 1622 | 1.83 / 175.24 | 2 | 12 |
4 | 13 | 1254.80 | 18 | 14.98 | 1982 | 534 | 2.36 / 175.78 | 2 | 16 |
5 | 13 | 764.60 | 18 | 15.07 | 1377 | 374 | 2.74 / 176.15 | 2 | 19 |
6 | 13 | 284.68 | 18 | 15.18 | 752 | 205 | 2.94 / 176.35 | 2 | 22 |
7 | 13 | 35.20 | 18 | 15.23 | 392 | 107 | 3.05 / 176.46 | 2 | 18 |
8 | 8 | 0.00 | 165 | 15.19 | 333 | 835 | 3.88 / 177.30 | 2 | 16 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 29 | 15.14 | 498 | 219 | 0.22 / 169.58 | 2 | 15 |
2 | 3 | 977.68 | -1 | 15.49 | 0 | 0 | 0.00 / 169.58 | 2 | 15 |
3 | 7 | 2003.96 | 38 | 14.86 | 2880 | 1626 | 1.84 / 171.20 | 2 | 12 |
4 | 13 | 1458.80 | 18 | 14.94 | 2234 | 601 | 2.45 / 171.80 | 2 | 16 |
5 | 13 | 901.72 | 18 | 15.04 | 1548 | 419 | 2.86 / 172.22 | 2 | 18 |
6 | 13 | 469.12 | 18 | 15.12 | 988 | 269 | 3.13 / 172.49 | 2 | 21 |
7 | 13 | 18.00 | 18 | 15.24 | 356 | 98 | 3.23 / 172.59 | 2 | 7 |
8 | 8 | 0.04 | 165 | 15.20 | 328 | 823 | 4.05 / 173.41 | 2 | 14 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 29 | 15.13 | 511 | 224 | 0.22 / 165.54 | 2 | 16 |
2 | 7 | 2004.20 | 39 | 14.85 | 2883 | 1670 | 1.89 / 167.21 | 2 | 12 |
3 | 13 | 1443.36 | 18 | 14.94 | 2223 | 598 | 2.49 / 167.81 | 2 | 15 |
4 | 13 | 869.76 | 18 | 15.04 | 1511 | 409 | 2.90 / 168.22 | 2 | 19 |
5 | 13 | 299.12 | 18 | 15.17 | 764 | 209 | 3.11 / 168.43 | 2 | 22 |
6 | 13 | 20.12 | 18 | 15.24 | 366 | 100 | 3.21 / 168.53 | 2 | 13 |
7 | 8 | 0.40 | 165 | 15.19 | 332 | 832 | 4.04 / 169.36 | 2 | 13 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 29 | 15.15 | 502 | 221 | 0.22 / 161.61 | 2 | 16 |
2 | 7 | 2012.40 | 38 | 14.86 | 2889 | 1631 | 1.85 / 163.24 | 2 | 12 |
3 | 13 | 1330.76 | 18 | 14.97 | 2079 | 560 | 2.41 / 163.80 | 2 | 17 |
4 | 13 | 722.36 | 18 | 15.08 | 1323 | 359 | 2.77 / 164.16 | 2 | 20 |
5 | 13 | 275.08 | 18 | 15.17 | 736 | 201 | 2.97 / 164.36 | 2 | 22 |
6 | 13 | 18.56 | 18 | 15.23 | 370 | 101 | 3.07 / 164.46 | 2 | 13 |
7 | 8 | 0.08 | 165 | 15.19 | 342 | 857 | 3.93 / 165.32 | 2 | 17 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 29 | 15.16 | 503 | 221 | 0.22 / 157.76 | 2 | 16 |
2 | 3 | 1016.28 | 1 | 15.16 | 1740 | 26 | 0.25 / 157.79 | 2 | 13 |
3 | 7 | 2003.60 | 38 | 14.87 | 2890 | 1633 | 1.88 / 159.42 | 2 | 12 |
4 | 13 | 1267.08 | 18 | 14.99 | 2004 | 541 | 2.42 / 159.96 | 2 | 17 |
5 | 13 | 829.12 | 18 | 15.07 | 1463 | 397 | 2.82 / 160.36 | 2 | 19 |
6 | 13 | 259.56 | 18 | 15.19 | 709 | 194 | 3.01 / 160.55 | 2 | 21 |
7 | 8 | 0.20 | 165 | 15.21 | 332 | 833 | 3.85 / 161.39 | 2 | 12 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 29 | 15.15 | 509 | 224 | 0.22 / 153.85 | 2 | 17 |
2 | 3 | 983.16 | -1 | 15.47 | 0 | 0 | 0.00 / 153.85 | 2 | 17 |
3 | 7 | 2004.88 | 38 | 14.88 | 2888 | 1633 | 1.86 / 155.48 | 2 | 12 |
4 | 13 | 1346.08 | 18 | 14.99 | 2101 | 567 | 2.42 / 156.05 | 2 | 16 |
5 | 13 | 775.28 | 18 | 15.08 | 1387 | 376 | 2.80 / 156.42 | 2 | 20 |
6 | 13 | 272.12 | 18 | 15.20 | 727 | 199 | 3.00 / 156.62 | 2 | 22 |
7 | 13 | 15.04 | 18 | 15.26 | 356 | 98 | 3.10 / 156.72 | 2 | 11 |
8 | 8 | -0.04 | 165 | 15.22 | 327 | 821 | 3.92 / 157.54 | 2 | 13 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.88 | 28 | 15.14 | 515 | 218 | 0.22 / 149.79 | 2 | 16 |
2 | 3 | 1022.56 | 1 | 15.16 | 1740 | 26 | 0.24 / 149.82 | 2 | 14 |
3 | 7 | 2005.92 | 38 | 14.87 | 2886 | 1631 | 1.88 / 151.45 | 2 | 12 |
4 | 13 | 1405.56 | 18 | 14.96 | 2170 | 584 | 2.46 / 152.03 | 2 | 16 |
5 | 13 | 846.04 | 18 | 15.06 | 1478 | 401 | 2.86 / 152.43 | 2 | 19 |
6 | 13 | 356.48 | 18 | 15.16 | 845 | 231 | 3.09 / 152.67 | 2 | 21 |
7 | 13 | 43.36 | 18 | 15.24 | 406 | 111 | 3.20 / 152.78 | 2 | 17 |
8 | 8 | -0.04 | 165 | 15.21 | 337 | 846 | 4.05 / 153.62 | 2 | 15 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 28 | 15.16 | 507 | 215 | 0.22 / 145.92 | 2 | 17 |
2 | 3 | 1030.00 | 1 | 15.14 | 1746 | 26 | 0.24 / 145.95 | 2 | 15 |
3 | 7 | 2006.84 | 38 | 14.88 | 2887 | 1632 | 1.87 / 147.58 | 2 | 12 |
4 | 13 | 1355.20 | 18 | 14.97 | 2094 | 564 | 2.44 / 148.15 | 2 | 17 |
5 | 13 | 862.76 | 18 | 15.05 | 1501 | 407 | 2.84 / 148.55 | 2 | 19 |
6 | 13 | 231.32 | 18 | 15.18 | 666 | 182 | 3.03 / 148.73 | 2 | 22 |
7 | 8 | 0.24 | 165 | 15.21 | 335 | 841 | 3.87 / 149.57 | 2 | 16 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 29 | 15.16 | 475 | 209 | 0.21 / 142.02 | 2 | 17 |
2 | 3 | 944.16 | -2 | 15.48 | 0 | 0 | 0.00 / 142.02 | 2 | 17 |
3 | 7 | 2004.28 | 38 | 14.88 | 2871 | 1623 | 1.83 / 143.64 | 2 | 13 |
4 | 13 | 1343.28 | 18 | 14.98 | 2077 | 560 | 2.39 / 144.20 | 2 | 17 |
5 | 13 | 758.00 | 18 | 15.09 | 1360 | 369 | 2.76 / 144.57 | 2 | 20 |
6 | 13 | 272.44 | 18 | 15.20 | 723 | 198 | 2.96 / 144.77 | 2 | 22 |
7 | 13 | 27.92 | 18 | 15.26 | 377 | 104 | 3.06 / 144.87 | 2 | 14 |
8 | 8 | 0.20 | 165 | 15.21 | 332 | 833 | 3.90 / 145.71 | 2 | 11 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 30 | 15.16 | 492 | 224 | 0.22 / 138.15 | 2 | 17 |
2 | 7 | 2007.28 | 38 | 14.88 | 2875 | 1626 | 1.85 / 139.77 | 2 | 12 |
3 | 13 | 1342.40 | 18 | 14.99 | 2072 | 559 | 2.41 / 140.33 | 2 | 17 |
4 | 13 | 810.08 | 18 | 15.09 | 1414 | 384 | 2.79 / 140.71 | 2 | 19 |
5 | 13 | 204.96 | 18 | 15.21 | 630 | 172 | 2.97 / 140.89 | 2 | 22 |
6 | 13 | 29.92 | 18 | 15.26 | 381 | 105 | 3.07 / 140.99 | 2 | 16 |
7 | 8 | 0.00 | 165 | 15.22 | 326 | 819 | 3.89 / 141.81 | 2 | 10 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 30 | 15.16 | 510 | 232 | 0.23 / 134.16 | 2 | 18 |
2 | 7 | 2006.52 | 39 | 14.88 | 2893 | 1679 | 1.91 / 135.84 | 2 | 13 |
3 | 13 | 1298.24 | 18 | 14.99 | 2039 | 550 | 2.46 / 136.39 | 2 | 17 |
4 | 13 | 844.20 | 18 | 15.06 | 1478 | 401 | 2.86 / 136.79 | 2 | 19 |
5 | 13 | 263.88 | 18 | 15.20 | 712 | 195 | 3.06 / 136.99 | 2 | 22 |
6 | 13 | 31.84 | 18 | 15.26 | 383 | 105 | 3.16 / 137.09 | 2 | 16 |
7 | 8 | -0.12 | 165 | 15.22 | 331 | 831 | 3.99 / 137.92 | 2 | 14 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 28 | 15.16 | 517 | 219 | 0.22 / 130.11 | 2 | 17 |
2 | 10 | 1028.00 | 3 | 15.09 | 1743 | 79 | 0.30 / 130.19 | 2 | 15 |
3 | 7 | 2006.40 | 38 | 14.89 | 2880 | 1630 | 1.93 / 131.82 | 2 | 12 |
4 | 13 | 1429.20 | 18 | 14.99 | 2197 | 593 | 2.52 / 132.41 | 2 | 16 |
5 | 13 | 806.16 | 18 | 15.08 | 1420 | 385 | 2.91 / 132.80 | 2 | 19 |
6 | 13 | 320.52 | 18 | 15.19 | 785 | 215 | 3.12 / 133.01 | 2 | 21 |
7 | 13 | 28.40 | 18 | 15.27 | 374 | 103 | 3.22 / 133.11 | 2 | 16 |
8 | 8 | 0.12 | 165 | 15.23 | 325 | 817 | 4.04 / 133.93 | 2 | 16 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 28 | 15.17 | 486 | 206 | 0.21 / 126.27 | 2 | 18 |
2 | 7 | 2005.96 | 38 | 14.89 | 2888 | 1634 | 1.84 / 127.90 | 2 | 13 |
3 | 13 | 1319.32 | 18 | 14.99 | 2070 | 559 | 2.40 / 128.46 | 2 | 17 |
4 | 13 | 797.52 | 18 | 15.08 | 1409 | 382 | 2.78 / 128.84 | 2 | 20 |
5 | 13 | 315.36 | 18 | 15.19 | 784 | 214 | 3.00 / 129.05 | 2 | 22 |
6 | 8 | 0.24 | 165 | 15.23 | 332 | 834 | 3.83 / 129.89 | 2 | 12 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 28 | 15.17 | 494 | 210 | 0.21 / 122.43 | 2 | 18 |
2 | 3 | 975.00 | -1 | 15.48 | 0 | 0 | 0.00 / 122.43 | 2 | 18 |
3 | 7 | 2007.32 | 38 | 14.88 | 2891 | 1635 | 1.84 / 124.07 | 2 | 13 |
4 | 13 | 1387.76 | 18 | 14.98 | 2155 | 581 | 2.43 / 124.65 | 2 | 16 |
5 | 13 | 802.84 | 18 | 15.08 | 1422 | 386 | 2.81 / 125.04 | 2 | 20 |
6 | 13 | 272.00 | 18 | 15.19 | 720 | 197 | 3.01 / 125.23 | 2 | 22 |
7 | 8 | 0.12 | 165 | 15.23 | 329 | 827 | 3.84 / 126.06 | 2 | 10 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 29 | 15.17 | 495 | 218 | 0.22 / 118.45 | 2 | 19 |
2 | 3 | 955.20 | -2 | 15.48 | 0 | 0 | 0.00 / 118.45 | 2 | 19 |
3 | 7 | 2011.60 | 38 | 14.89 | 2903 | 1643 | 1.86 / 120.09 | 2 | 14 |
4 | 13 | 1389.40 | 18 | 15.00 | 2153 | 581 | 2.44 / 120.67 | 2 | 17 |
5 | 13 | 761.00 | 18 | 15.10 | 1366 | 371 | 2.81 / 121.04 | 2 | 20 |
6 | 13 | 374.60 | 18 | 15.18 | 866 | 237 | 3.05 / 121.28 | 2 | 22 |
7 | 13 | 26.00 | 18 | 15.28 | 374 | 103 | 3.15 / 121.38 | 2 | 16 |
8 | 8 | -0.04 | 165 | 15.23 | 335 | 842 | 3.99 / 122.22 | 2 | 11 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 29 | 15.16 | 507 | 223 | 0.22 / 114.50 | 2 | 18 |
2 | 3 | 1030.60 | 1 | 15.16 | 1762 | 27 | 0.25 / 114.53 | 2 | 15 |
3 | 7 | 2005.00 | 38 | 14.90 | 2889 | 1636 | 1.89 / 116.16 | 2 | 13 |
4 | 13 | 1405.68 | 18 | 15.00 | 2171 | 586 | 2.47 / 116.75 | 2 | 17 |
5 | 13 | 863.84 | 18 | 15.08 | 1502 | 408 | 2.88 / 117.16 | 2 | 20 |
6 | 13 | 344.88 | 18 | 15.19 | 831 | 227 | 3.11 / 117.38 | 2 | 22 |
7 | 8 | 0.24 | 165 | 15.24 | 336 | 845 | 3.95 / 118.23 | 2 | 9 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 28 | 15.19 | 497 | 211 | 0.21 / 110.56 | 2 | 18 |
2 | 3 | 1025.20 | 1 | 15.17 | 1742 | 26 | 0.24 / 110.59 | 2 | 16 |
3 | 7 | 2004.08 | 38 | 14.90 | 2883 | 1632 | 1.87 / 112.22 | 2 | 13 |
4 | 13 | 1340.24 | 18 | 15.00 | 2092 | 565 | 2.44 / 112.79 | 2 | 17 |
5 | 13 | 782.00 | 18 | 15.10 | 1400 | 381 | 2.82 / 113.17 | 2 | 20 |
6 | 13 | 211.16 | 18 | 15.24 | 642 | 176 | 2.99 / 113.34 | 2 | 23 |
7 | 13 | 14.72 | 18 | 15.28 | 354 | 97 | 3.09 / 113.44 | 2 | 7 |
8 | 8 | 0.16 | 165 | 15.23 | 333 | 837 | 3.93 / 114.28 | 2 | 13 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 29 | 15.18 | 496 | 218 | 0.22 / 106.69 | 2 | 18 |
2 | 3 | 970.32 | -1 | 15.50 | 0 | 0 | 0.00 / 106.69 | 2 | 18 |
3 | 7 | 2010.88 | 39 | 14.90 | 2883 | 1675 | 1.89 / 108.36 | 2 | 13 |
4 | 13 | 1352.92 | 18 | 15.00 | 2094 | 565 | 2.46 / 108.93 | 2 | 17 |
5 | 13 | 804.88 | 18 | 15.10 | 1423 | 387 | 2.85 / 109.31 | 2 | 21 |
6 | 13 | 259.92 | 18 | 15.22 | 710 | 195 | 3.04 / 109.51 | 2 | 23 |
7 | 8 | 0.20 | 165 | 15.24 | 336 | 845 | 3.89 / 110.35 | 2 | 13 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.00 | 28 | 15.16 | 503 | 214 | 0.21 / 102.68 | 2 | 16 |
2 | 3 | 1030.48 | 1 | 15.16 | 1761 | 27 | 0.24 / 102.71 | 2 | 14 |
3 | 7 | 2003.84 | 38 | 14.89 | 2876 | 1627 | 1.87 / 104.33 | 2 | 13 |
4 | 13 | 1382.36 | 18 | 14.99 | 2139 | 577 | 2.44 / 104.91 | 2 | 17 |
5 | 13 | 746.40 | 18 | 15.11 | 1353 | 368 | 2.81 / 105.28 | 2 | 20 |
6 | 13 | 256.96 | 18 | 15.22 | 702 | 192 | 3.00 / 105.47 | 2 | 23 |
7 | 8 | -0.08 | 165 | 15.24 | 335 | 842 | 3.85 / 106.31 | 2 | 12 |
8 | 14 | -0.08 | 30 | 15.22 | 334 | 153 | 4.00 / 106.47 | 2 | 14 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 29 | 15.17 | 481 | 212 | 0.21 / 98.75 | 2 | 16 |
2 | 3 | 946.08 | -2 | 15.49 | 0 | 0 | 0.00 / 98.75 | 2 | 16 |
3 | 7 | 2009.48 | 38 | 14.90 | 2888 | 1635 | 1.85 / 100.39 | 2 | 11 |
4 | 13 | 1260.56 | 18 | 15.02 | 1982 | 536 | 2.38 / 100.93 | 2 | 16 |
5 | 13 | 788.44 | 18 | 15.09 | 1400 | 380 | 2.76 / 101.31 | 2 | 18 |
6 | 13 | 323.76 | 18 | 15.19 | 793 | 217 | 2.98 / 101.52 | 2 | 21 |
7 | 13 | 71.64 | 18 | 15.27 | 437 | 120 | 3.10 / 101.64 | 2 | 19 |
8 | 8 | 0.12 | 165 | 15.23 | 328 | 824 | 3.92 / 102.47 | 2 | 12 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 28 | 15.19 | 500 | 213 | 0.21 / 94.80 | 2 | 15 |
2 | 10 | 1039.44 | 2 | 15.13 | 1766 | 53 | 0.27 / 94.86 | 2 | 13 |
3 | 7 | 2004.36 | 38 | 14.90 | 2875 | 1628 | 1.89 / 96.49 | 2 | 11 |
4 | 13 | 1314.04 | 18 | 15.02 | 2061 | 557 | 2.45 / 97.04 | 2 | 15 |
5 | 13 | 778.44 | 18 | 15.11 | 1381 | 376 | 2.83 / 97.42 | 2 | 18 |
6 | 13 | 246.20 | 18 | 15.22 | 688 | 188 | 3.02 / 97.61 | 2 | 21 |
7 | 13 | 49.40 | 18 | 15.28 | 405 | 111 | 3.13 / 97.72 | 2 | 17 |
8 | 8 | 0.56 | 165 | 15.23 | 328 | 824 | 3.95 / 98.54 | 2 | 11 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 29 | 15.18 | 491 | 216 | 0.22 / 90.95 | 2 | 14 |
2 | 3 | 928.56 | -2 | 15.50 | 0 | 0 | 0.00 / 90.95 | 2 | 14 |
3 | 7 | 2007.48 | 38 | 14.92 | 2880 | 1633 | 1.85 / 92.58 | 2 | 10 |
4 | 13 | 1359.44 | 18 | 15.02 | 2110 | 570 | 2.42 / 93.15 | 2 | 14 |
5 | 13 | 824.40 | 18 | 15.10 | 1446 | 393 | 2.81 / 93.54 | 2 | 17 |
6 | 13 | 275.32 | 18 | 15.22 | 725 | 199 | 3.01 / 93.74 | 2 | 20 |
7 | 8 | -0.04 | 165 | 15.25 | 338 | 850 | 3.86 / 94.59 | 2 | 8 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 29 | 15.19 | 479 | 211 | 0.21 / 87.13 | 2 | 15 |
2 | 7 | 2011.80 | 38 | 14.91 | 2880 | 1632 | 1.84 / 88.77 | 2 | 11 |
3 | 13 | 1254.60 | 18 | 15.04 | 1976 | 535 | 2.38 / 89.30 | 2 | 16 |
4 | 13 | 821.48 | 18 | 15.10 | 1439 | 391 | 2.77 / 89.69 | 2 | 18 |
5 | 13 | 270.40 | 18 | 15.23 | 716 | 196 | 2.97 / 89.89 | 2 | 20 |
6 | 8 | 0.04 | 165 | 15.25 | 335 | 843 | 3.81 / 90.73 | 2 | 11 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 29 | 15.19 | 505 | 222 | 0.22 / 83.19 | 2 | 14 |
2 | 3 | 1028.64 | 1 | 15.19 | 1754 | 27 | 0.25 / 83.22 | 2 | 13 |
3 | 7 | 2002.36 | 38 | 14.92 | 2871 | 1628 | 1.88 / 84.85 | 2 | 11 |
4 | 13 | 1352.96 | 18 | 15.01 | 2082 | 563 | 2.44 / 85.41 | 2 | 16 |
5 | 13 | 776.12 | 18 | 15.11 | 1379 | 375 | 2.81 / 85.78 | 2 | 19 |
6 | 13 | 279.92 | 18 | 15.22 | 737 | 202 | 3.02 / 85.99 | 2 | 21 |
7 | 13 | 71.08 | 18 | 15.28 | 435 | 120 | 3.14 / 86.11 | 2 | 19 |
8 | 8 | 0.12 | 165 | 15.24 | 325 | 817 | 3.95 / 86.92 | 2 | 18 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 29 | 15.19 | 504 | 222 | 0.22 / 79.34 | 2 | 15 |
2 | 7 | 2006.64 | 38 | 14.93 | 2882 | 1635 | 1.86 / 80.97 | 2 | 12 |
3 | 13 | 1350.80 | 18 | 15.04 | 2096 | 567 | 2.42 / 81.54 | 2 | 16 |
4 | 13 | 813.36 | 18 | 15.11 | 1433 | 390 | 2.81 / 81.93 | 2 | 18 |
5 | 13 | 307.08 | 18 | 15.23 | 775 | 212 | 3.03 / 82.14 | 2 | 21 |
6 | 8 | 0.12 | 165 | 15.26 | 329 | 828 | 3.86 / 82.97 | 2 | 13 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 28 | 15.20 | 500 | 213 | 0.21 / 75.36 | 2 | 13 |
2 | 10 | 1027.84 | 2 | 15.17 | 1752 | 53 | 0.27 / 75.41 | 2 | 13 |
3 | 7 | 2005.28 | 39 | 14.93 | 2870 | 1671 | 1.94 / 77.08 | 2 | 11 |
4 | 13 | 1255.32 | 18 | 15.06 | 1985 | 538 | 2.48 / 77.62 | 2 | 15 |
5 | 13 | 788.32 | 18 | 15.12 | 1397 | 380 | 2.86 / 78.00 | 2 | 18 |
6 | 13 | 251.68 | 18 | 15.24 | 689 | 189 | 3.04 / 78.19 | 2 | 21 |
7 | 13 | 51.00 | 18 | 15.30 | 407 | 112 | 3.16 / 78.30 | 2 | 18 |
8 | 8 | 0.04 | 165 | 15.25 | 324 | 815 | 3.97 / 79.11 | 2 | 12 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 28 | 15.21 | 484 | 206 | 0.21 / 71.43 | 2 | 12 |
2 | 3 | 963.36 | -1 | 15.53 | 0 | 0 | 0.00 / 71.43 | 2 | 12 |
3 | 7 | 2011.76 | 38 | 14.94 | 2869 | 1629 | 1.83 / 73.05 | 2 | 10 |
4 | 13 | 1338.52 | 18 | 15.05 | 2082 | 564 | 2.40 / 73.62 | 2 | 15 |
5 | 13 | 797.72 | 18 | 15.13 | 1409 | 384 | 2.78 / 74.00 | 2 | 18 |
6 | 13 | 286.64 | 18 | 15.23 | 742 | 203 | 2.99 / 74.21 | 2 | 20 |
7 | 13 | 40.92 | 18 | 15.30 | 400 | 110 | 3.10 / 74.32 | 2 | 16 |
8 | 8 | -0.04 | 165 | 15.27 | 328 | 826 | 3.92 / 75.14 | 2 | 17 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 29 | 15.22 | 478 | 211 | 0.21 / 67.43 | 2 | 11 |
2 | 3 | 983.48 | -1 | 15.53 | 0 | 0 | 0.00 / 67.43 | 2 | 11 |
3 | 7 | 2008.80 | 38 | 14.95 | 2874 | 1633 | 1.84 / 69.06 | 2 | 9 |
4 | 13 | 1479.16 | 18 | 15.03 | 2243 | 607 | 2.45 / 69.67 | 2 | 13 |
5 | 13 | 898.88 | 18 | 15.12 | 1527 | 416 | 2.87 / 70.08 | 2 | 16 |
6 | 13 | 250.28 | 18 | 15.26 | 686 | 188 | 3.05 / 70.27 | 2 | 19 |
7 | 13 | 28.92 | 18 | 15.30 | 388 | 107 | 3.16 / 70.38 | 2 | 14 |
8 | 8 | 0.00 | 165 | 15.26 | 335 | 843 | 4.00 / 71.22 | 2 | 10 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 29 | 15.20 | 487 | 215 | 0.21 / 63.67 | 2 | 10 |
2 | 7 | 2003.24 | 38 | 14.94 | 2873 | 1631 | 1.85 / 65.30 | 2 | 8 |
3 | 13 | 1299.44 | 18 | 15.06 | 2018 | 547 | 2.39 / 65.85 | 2 | 12 |
4 | 13 | 725.60 | 18 | 15.16 | 1309 | 357 | 2.75 / 66.21 | 2 | 15 |
5 | 13 | 239.48 | 18 | 15.26 | 672 | 185 | 2.93 / 66.39 | 2 | 18 |
6 | 8 | 0.16 | 165 | 15.28 | 326 | 822 | 3.76 / 67.22 | 2 | 8 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 27 | 15.20 | 497 | 204 | 0.20 / 59.72 | 2 | 11 |
2 | 3 | 1048.00 | 1 | 15.20 | 1780 | 27 | 0.23 / 59.75 | 2 | 12 |
3 | 7 | 2007.64 | 38 | 14.94 | 2885 | 1638 | 1.87 / 61.38 | 2 | 10 |
4 | 13 | 1346.04 | 18 | 15.05 | 2095 | 568 | 2.44 / 61.95 | 2 | 14 |
5 | 13 | 807.72 | 18 | 15.13 | 1423 | 388 | 2.82 / 62.34 | 2 | 17 |
6 | 13 | 263.92 | 18 | 15.26 | 708 | 194 | 3.02 / 62.53 | 2 | 20 |
7 | 13 | 35.20 | 18 | 15.31 | 386 | 106 | 3.12 / 62.64 | 2 | 15 |
8 | 8 | 0.08 | 165 | 15.26 | 325 | 818 | 3.94 / 63.46 | 2 | 14 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 29 | 15.23 | 464 | 205 | 0.20 / 55.85 | 2 | 11 |
2 | 3 | 930.80 | -2 | 15.54 | 0 | 0 | 0.00 / 55.85 | 2 | 11 |
3 | 7 | 2007.72 | 38 | 14.95 | 2881 | 1637 | 1.84 / 57.49 | 2 | 11 |
4 | 13 | 1311.00 | 18 | 15.05 | 2047 | 555 | 2.40 / 58.04 | 2 | 15 |
5 | 13 | 782.60 | 18 | 15.14 | 1380 | 376 | 2.77 / 58.42 | 2 | 18 |
6 | 13 | 215.92 | 18 | 15.27 | 637 | 175 | 2.95 / 58.59 | 2 | 20 |
7 | 13 | 42.24 | 18 | 15.31 | 389 | 107 | 3.05 / 58.70 | 2 | 16 |
8 | 8 | 0.08 | 165 | 15.27 | 324 | 816 | 3.87 / 59.52 | 2 | 12 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 29 | 15.22 | 480 | 212 | 0.21 / 51.97 | 2 | 9 |
2 | 7 | 2002.72 | 38 | 14.95 | 2881 | 1637 | 1.85 / 53.60 | 2 | 9 |
3 | 13 | 1315.04 | 18 | 15.06 | 2037 | 552 | 2.40 / 54.16 | 2 | 14 |
4 | 13 | 772.52 | 18 | 15.15 | 1370 | 374 | 2.77 / 54.53 | 2 | 17 |
5 | 13 | 274.08 | 18 | 15.26 | 715 | 196 | 2.97 / 54.73 | 2 | 19 |
6 | 13 | 34.64 | 18 | 15.31 | 382 | 105 | 3.08 / 54.83 | 2 | 14 |
7 | 8 | 0.12 | 165 | 15.26 | 323 | 813 | 3.89 / 55.64 | 2 | 10 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 29 | 15.21 | 478 | 211 | 0.21 / 48.12 | 2 | 10 |
2 | 7 | 2003.24 | 38 | 14.95 | 2868 | 1629 | 1.84 / 49.75 | 2 | 9 |
3 | 13 | 1341.28 | 18 | 15.06 | 2074 | 562 | 2.40 / 50.31 | 2 | 13 |
4 | 13 | 763.28 | 18 | 15.15 | 1355 | 370 | 2.77 / 50.68 | 2 | 17 |
5 | 13 | 276.60 | 18 | 15.26 | 711 | 195 | 2.97 / 50.87 | 2 | 19 |
6 | 13 | 21.48 | 18 | 15.31 | 354 | 98 | 3.06 / 50.97 | 2 | 13 |
7 | 8 | 0.04 | 165 | 15.27 | 311 | 784 | 3.85 / 51.76 | 2 | 11 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 29 | 15.22 | 484 | 214 | 0.21 / 44.20 | 2 | 10 |
2 | 7 | 2003.48 | 38 | 14.96 | 2873 | 1633 | 1.85 / 45.84 | 2 | 10 |
3 | 13 | 1422.64 | 18 | 15.05 | 2177 | 590 | 2.44 / 46.43 | 2 | 13 |
4 | 13 | 771.92 | 18 | 15.15 | 1360 | 371 | 2.81 / 46.80 | 2 | 17 |
5 | 13 | 280.04 | 18 | 15.25 | 719 | 197 | 3.00 / 46.99 | 2 | 20 |
6 | 13 | 25.60 | 18 | 15.32 | 365 | 101 | 3.11 / 47.10 | 2 | 14 |
7 | 8 | 0.16 | 165 | 15.27 | 322 | 811 | 3.92 / 47.91 | 2 | 14 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 29 | 15.21 | 481 | 212 | 0.21 / 40.32 | 2 | 13 |
2 | 7 | 2011.40 | 39 | 14.94 | 2879 | 1677 | 1.89 / 42.00 | 2 | 11 |
3 | 13 | 1343.96 | 18 | 15.05 | 2072 | 561 | 2.45 / 42.56 | 2 | 15 |
4 | 13 | 715.84 | 18 | 15.16 | 1290 | 352 | 2.80 / 42.91 | 2 | 18 |
5 | 13 | 269.68 | 18 | 15.26 | 702 | 193 | 3.00 / 43.11 | 2 | 20 |
6 | 13 | 17.20 | 18 | 15.32 | 344 | 95 | 3.09 / 43.20 | 2 | 11 |
7 | 8 | 0.16 | 165 | 15.27 | 313 | 789 | 3.88 / 43.99 | 2 | 11 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 29 | 15.23 | 489 | 216 | 0.22 / 36.48 | 2 | 13 |
2 | 7 | 2002.32 | 38 | 14.96 | 2865 | 1629 | 1.84 / 38.11 | 2 | 12 |
3 | 13 | 1305.36 | 18 | 15.07 | 2031 | 551 | 2.40 / 38.66 | 2 | 15 |
4 | 13 | 778.72 | 18 | 15.15 | 1367 | 373 | 2.77 / 39.03 | 2 | 18 |
5 | 13 | 275.04 | 18 | 15.25 | 712 | 195 | 2.96 / 39.22 | 2 | 21 |
6 | 13 | 19.56 | 18 | 15.32 | 353 | 97 | 3.06 / 39.32 | 2 | 13 |
7 | 8 | -0.04 | 165 | 15.28 | 313 | 789 | 3.85 / 40.11 | 2 | 9 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 28 | 15.25 | 483 | 206 | 0.21 / 31.93 | 2 | 14 |
2 | 7 | 2005.32 | 74 | 14.84 | 2856 | 3136 | 3.34 / 35.07 | 2 | 13 |
3 | 13 | 474.92 | 18 | 15.23 | 977 | 268 | 3.61 / 35.33 | 2 | 20 |
4 | 13 | 97.76 | 18 | 15.31 | 469 | 129 | 3.74 / 35.46 | 2 | 20 |
5 | 8 | 0.16 | 165 | 15.30 | 316 | 798 | 4.54 / 36.26 | 2 | 13 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 27 | 15.24 | 478 | 197 | 0.20 / 27.31 | 2 | 13 |
2 | 10 | 1003.20 | 2 | 15.19 | 1719 | 52 | 0.25 / 27.36 | 2 | 12 |
3 | 7 | 2006.60 | 74 | 14.86 | 2862 | 3147 | 3.40 / 30.51 | 2 | 12 |
4 | 13 | 531.60 | 18 | 15.21 | 1057 | 289 | 3.69 / 30.80 | 2 | 19 |
5 | 13 | 114.48 | 18 | 15.30 | 491 | 135 | 3.82 / 30.93 | 2 | 21 |
6 | 8 | 0.00 | 165 | 15.29 | 313 | 790 | 4.61 / 31.72 | 2 | 11 |
Average= | 3.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 29 | 15.29 | 488 | 216 | 0.22 / 22.86 | 2 | 15 |
2 | 3 | 947.04 | -1 | 15.60 | 0 | 0 | 0.00 / 22.86 | 2 | 15 |
3 | 3 | 972.56 | -1 | 15.61 | 0 | 0 | 0.00 / 22.86 | 2 | 15 |
4 | 7 | 2004.56 | 74 | 14.85 | 2852 | 3134 | 3.35 / 26.00 | 2 | 13 |
5 | 13 | 328.20 | 18 | 15.27 | 784 | 215 | 3.57 / 26.21 | 2 | 21 |
6 | 13 | 60.64 | 18 | 15.33 | 408 | 113 | 3.68 / 26.32 | 2 | 18 |
7 | 8 | 0.36 | 165 | 15.29 | 313 | 790 | 4.47 / 27.11 | 2 | 14 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 27 | 15.29 | 489 | 202 | 0.20 / 19.70 | 2 | 15 |
2 | 7 | 1251.92 | 74 | 15.09 | 1926 | 2151 | 2.35 / 21.85 | 2 | 16 |
3 | 8 | -0.12 | 165 | 15.35 | 312 | 790 | 3.14 / 22.64 | 2 | 11 |
Average= | 2.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.84 | 27 | 15.31 | 480 | 198 | 0.20 / 16.73 | 2 | 15 |
2 | 7 | 1107.56 | 74 | 15.14 | 1753 | 1964 | 2.16 / 18.69 | 2 | 17 |
3 | 8 | -0.04 | 165 | 15.36 | 320 | 811 | 2.97 / 19.50 | 2 | 12 |
Average= | 2.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 27 | 15.29 | 500 | 206 | 0.21 / 13.75 | 2 | 13 |
2 | 7 | 1122.24 | 74 | 15.14 | 1769 | 1982 | 2.19 / 15.73 | 2 | 17 |
3 | 8 | 0.16 | 165 | 15.37 | 313 | 794 | 2.98 / 16.53 | 2 | 11 |
Average= | 2.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 26 | 15.30 | 479 | 191 | 0.19 / 10.76 | 2 | 14 |
2 | 3 | 1023.24 | 1 | 15.28 | 1755 | 27 | 0.22 / 10.79 | 2 | 13 |
3 | 7 | 1101.68 | 74 | 15.14 | 1745 | 1955 | 2.17 / 12.74 | 2 | 17 |
4 | 8 | 0.28 | 165 | 15.36 | 318 | 806 | 2.98 / 13.55 | 2 | 11 |
Average= | 2.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 24 | 15.32 | 490 | 180 | 0.18 / 7.75 | 2 | 15 |
2 | 10 | 1017.00 | 2 | 15.22 | 1714 | 52 | 0.23 / 7.80 | 2 | 13 |
3 | 3 | 1029.40 | 1 | 15.28 | 1758 | 27 | 0.26 / 7.83 | 2 | 14 |
4 | 7 | 1093.92 | 74 | 15.14 | 1737 | 1946 | 2.21 / 9.78 | 2 | 17 |
5 | 8 | 0.12 | 165 | 15.37 | 312 | 791 | 3.00 / 10.57 | 2 | 11 |
Average= | 2.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.44 | 31 | 15.30 | 469 | 222 | 0.22 / 4.96 | 2 | 15 |
2 | 3 | 842.60 | -3 | 15.61 | 0 | 0 | 0.00 / 4.96 | 2 | 15 |
3 | 3 | 877.28 | -2 | 15.62 | 0 | 0 | 0.00 / 4.96 | 2 | 15 |
4 | 7 | 1003.00 | 74 | 15.19 | 1617 | 1818 | 2.04 / 6.77 | 2 | 17 |
5 | 8 | 0.08 | 165 | 15.38 | 314 | 797 | 2.84 / 7.57 | 2 | 12 |
Average= | 2.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 26 | 15.42 | 458 | 184 | 0.18 / 2.10 | 2 | 8 |
2 | 7 | 1003.40 | 75 | 15.15 | 1618 | 1838 | 2.02 / 3.93 | 2 | 16 |
3 | 8 | 0.04 | 165 | 15.36 | 316 | 801 | 2.82 / 4.73 | 2 | 11 |
Average= | 2.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 162.36 | 26 | 15.58 | 524 | 212 | 0.21 / 0.21 | 2 | 7 |
2 | 7 | 177.76 | 74 | 15.53 | 540 | 621 | 0.83 / 0.83 | 2 | 11 |
3 | 8 | 0.16 | 240 | 15.50 | 290 | 1079 | 1.91 / 1.91 | 2 | 22 |
Average= | 1.91 (KJ/cycle) |