SIO Argo Site:
Pump Diagnostics Page   



Serial= 6102 WMO= 5906931

Return

←PreviousNext→

Cycle 71 GMT 12/11/2024 14:42: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.2 8 78 14.98 455 532 0.53 / 1383.34 2 11
2 6 5861.4 716 82 14.34 4123 4848 5.38 / 1388.19 2 41
3 3 5335.6 897 7 14.60 3857 394 5.77 / 1388.58 2 43
4 7 5121.8 12002 80 14.56 3688 4296 10.07 / 1392.88 2 48
5 13 4073.6 12248 80 14.53 3047 3542 13.61 / 1396.42 2 52
6 13 2907.0 12518 80 14.67 2328 2732 16.34 / 1399.15 2 53
7 13 1981.3 12698 80 14.78 1745 2063 18.41 / 1401.22 2 51
8 13 1138.1 12842 80 14.90 1203 1434 19.84 / 1402.65 2 50
9 13 749.3 12896 80 14.93 933 1114 20.96 / 1403.77 2 48
10 13 710.1 12900 80 14.88 913 1087 22.04 / 1404.85 2 87
11 14 0.7 12974 54 15.00 425 344 22.39 / 1405.20 2 111
12 14 0.8 12975 46 14.98 406 280 22.67 / 1405.48 24 246
Average= 19.52
(KJ/cycle)

Cycle 70 GMT 2/11/2024 17:17: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.3 8 78 15.00 451 528 0.53 / 1360.75 2 10
2 6 5716.3 678 80 14.37 4033 4636 5.16 / 1365.39 2 41
3 3 5299.4 859 5 14.61 3828 280 5.44 / 1365.67 2 44
4 7 5182.0 12002 80 14.55 3731 4343 9.79 / 1370.01 2 48
5 13 4129.7 12260 80 14.53 3069 3567 13.35 / 1373.58 2 51
6 13 3105.5 12476 80 14.63 2458 2877 16.23 / 1376.46 2 52
7 13 1988.1 12704 80 14.79 1755 2077 18.31 / 1378.53 2 52
8 13 1148.4 12848 80 14.90 1216 1449 19.76 / 1379.98 2 51
9 13 747.8 12908 80 14.94 936 1119 20.88 / 1381.10 2 46
10 13 709.5 12912 80 14.89 903 1076 21.95 / 1382.18 2 81
11 14 1.0 12984 54 15.00 431 349 22.30 / 1382.53 2 108
12 14 1.1 12984 46 14.98 413 285 22.58 / 1382.81 21 246
Average= 19.48
(KJ/cycle)

Cycle 69 GMT 23/10/2024 20:19: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.1 8 78 15.01 453 530 0.53 / 1339.32 2 11
2 6 5495.3 634 81 14.38 3909 4553 5.08 / 1343.87 2 42
3 7 5222.3 12002 80 14.56 3733 4348 9.43 / 1348.22 2 48
4 13 4238.8 12242 80 14.51 3141 3646 13.08 / 1351.86 2 51
5 13 3168.2 12470 80 14.62 2479 2899 15.98 / 1354.76 2 53
6 13 1984.7 12698 80 14.79 1744 2064 18.04 / 1356.83 2 51
7 13 1364.9 12800 80 14.85 1343 1595 19.64 / 1358.42 2 52
8 13 742.9 12887 80 14.94 933 1115 20.75 / 1359.54 2 47
9 14 0.3 12980 112 15.02 410 690 21.44 / 1360.23 2 105
Average= 19.43
(KJ/cycle)

Cycle 68 GMT 14/10/2024 0:10: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.2 8 78 15.00 460 538 0.54 / 1318.13 2 12
2 6 5144.4 573 95 14.40 3671 5022 5.56 / 1323.15 2 43
3 7 4969.8 12002 80 14.58 3591 4189 9.75 / 1327.34 2 48
4 13 4133.1 12194 80 14.53 3058 3555 13.30 / 1330.90 2 52
5 13 2796.6 12482 80 14.69 2269 2667 15.97 / 1333.56 2 54
6 13 1974.8 12632 80 14.78 1745 2063 18.03 / 1335.63 2 53
7 13 1103.8 12776 80 14.91 1185 1413 19.45 / 1337.04 2 51
8 13 721.0 12827 80 14.93 923 1102 20.55 / 1338.14 2 48
9 14 0.8 12914 103 15.02 416 644 21.19 / 1338.78 2 110
Average= 19.40
(KJ/cycle)

Cycle 67 GMT 4/10/2024 6: 5: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.7 8 79 15.01 454 538 0.54 / 1296.45 2 11
2 6 5754.0 699 81 14.36 4071 4735 5.27 / 1301.19 2 41
3 3 5237.6 880 2 14.67 3919 115 5.39 / 1301.30 2 33
4 7 5192.9 12002 80 14.56 3733 4348 9.74 / 1305.65 2 48
5 13 4306.1 12218 80 14.51 3184 3696 13.43 / 1309.35 2 51
6 13 3052.6 12494 80 14.66 2414 2831 16.26 / 1312.18 2 52
7 13 1990.8 12704 80 14.79 1746 2066 18.33 / 1314.25 2 53
8 13 1268.2 12824 80 14.88 1278 1521 19.85 / 1315.77 2 52
9 13 747.1 12899 80 14.94 935 1118 20.97 / 1316.88 2 47
10 14 0.5 12991 112 15.02 421 708 21.68 / 1317.59 2 103
Average= 19.38
(KJ/cycle)

Cycle 66 GMT 24/ 9/2024 8:37: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.4 8 78 15.01 451 528 0.53 / 1275.01 2 11
2 6 5734.1 682 82 14.36 4039 4756 5.28 / 1279.76 2 41
3 3 5315.3 862 6 14.60 3866 339 5.62 / 1280.10 2 43
4 7 5126.5 12002 80 14.57 3666 4273 9.90 / 1284.38 2 49
5 13 4073.2 12254 80 14.54 3022 3515 13.41 / 1287.89 2 51
6 13 2961.9 12506 80 14.67 2344 2751 16.16 / 1290.64 2 52
7 13 1999.5 12698 80 14.79 1764 2087 18.25 / 1292.73 2 53
8 13 1138.0 12842 80 14.91 1206 1439 19.69 / 1294.17 2 49
9 13 735.9 12899 80 14.94 931 1113 20.80 / 1295.28 2 48
10 14 0.5 12991 103 15.03 410 635 21.44 / 1295.92 2 108
Average= 19.34
(KJ/cycle)

Cycle 65 GMT 14/ 9/2024 11:27: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.9 8 79 15.01 456 541 0.54 / 1253.21 2 12
2 6 5896.8 731 81 14.34 4158 4830 5.37 / 1258.04 2 42
3 3 5345.2 912 8 14.59 3844 449 5.82 / 1258.48 2 43
4 7 5093.7 12183 80 14.57 3682 4292 10.11 / 1262.78 2 47
5 13 4215.2 12375 80 14.52 3126 3631 13.74 / 1266.41 2 51
6 13 2985.1 12639 80 14.66 2383 2795 16.54 / 1269.20 2 53
7 13 1997.9 12831 80 14.79 1755 2077 18.61 / 1271.28 2 51
8 13 1185.9 12963 80 14.90 1237 1475 20.09 / 1272.75 2 52
9 13 721.3 13025 80 14.94 919 1098 21.19 / 1273.85 2 48
10 14 0.5 13115 101 15.03 414 628 21.81 / 1274.48 2 112
Average= 19.31
(KJ/cycle)

Cycle 64 GMT 4/ 9/2024 14:28: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.8 8 79 15.01 459 544 0.54 / 1231.40 2 13
2 6 5889.2 744 81 14.35 4125 4795 5.34 / 1236.20 2 41
3 3 5332.3 924 7 14.60 3858 394 5.73 / 1236.59 2 42
4 7 5122.5 12183 80 14.58 3667 4277 10.01 / 1240.87 2 47
5 13 4334.7 12369 80 14.51 3200 3715 13.73 / 1244.58 2 51
6 13 2908.9 12663 80 14.68 2337 2745 16.47 / 1247.33 2 52
7 13 1980.9 12843 80 14.79 1755 2077 18.55 / 1249.41 2 53
8 13 1186.7 12975 80 14.90 1243 1482 20.03 / 1250.89 2 51
9 13 734.1 13037 80 14.94 939 1122 21.15 / 1252.01 2 46
10 14 0.3 13128 105 15.03 416 657 21.81 / 1252.67 2 111
Average= 19.27
(KJ/cycle)

Cycle 63 GMT 25/ 8/2024 17: 1: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.9 8 78 14.98 464 542 0.54 / 1209.61 2 13
2 6 5838.5 714 82 14.35 4100 4824 5.37 / 1214.43 2 41
3 3 5333.5 895 7 14.59 3859 394 5.76 / 1214.83 2 42
4 7 5123.1 12002 80 14.58 3670 4281 10.04 / 1219.11 2 48
5 13 4146.9 12236 80 14.54 3073 3575 13.62 / 1222.68 2 51
6 13 3079.4 12470 80 14.65 2438 2857 16.47 / 1225.54 2 52
7 13 1985.1 12674 80 14.80 1748 2070 18.54 / 1227.61 2 52
8 13 1176.8 12812 80 14.90 1233 1470 20.01 / 1229.08 2 50
9 13 717.3 12875 80 14.95 921 1102 21.11 / 1230.18 2 46
10 14 0.3 12964 108 15.03 419 680 21.79 / 1230.86 2 105
Average= 19.23
(KJ/cycle)

Cycle 62 GMT 15/ 8/2024 19:48: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.5 8 79 15.01 461 547 0.55 / 1187.02 2 13
2 6 5752.1 704 81 14.37 4053 4718 5.26 / 1191.74 2 42
3 3 5282.2 885 4 14.63 3829 224 5.49 / 1191.96 2 41
4 7 5153.9 12002 80 14.57 3697 4309 9.80 / 1196.27 2 47
5 13 4133.3 12248 80 14.54 3075 3577 13.37 / 1199.85 2 52
6 13 3082.2 12470 80 14.65 2429 2847 16.22 / 1202.70 2 53
7 13 1976.9 12680 80 14.80 1748 2070 18.29 / 1204.77 2 51
8 13 1159.8 12818 80 14.91 1217 1452 19.74 / 1206.22 2 50
9 13 749.2 12876 80 14.95 940 1124 20.87 / 1207.34 2 46
10 13 712.9 12880 80 14.89 909 1083 21.95 / 1208.43 2 84
11 14 0.7 12952 54 15.01 437 354 22.30 / 1208.78 2 111
12 14 0.9 12953 46 14.99 414 285 22.59 / 1209.06 24 246
Average= 19.19
(KJ/cycle)

Cycle 61 GMT 5/ 8/2024 22:58: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 73.7 8 79 15.01 472 560 0.56 / 1165.23 2 13
2 6 5784.4 710 81 14.36 4105 4775 5.33 / 1170.00 2 41
3 3 5291.6 891 5 14.63 3857 282 5.62 / 1170.29 2 43
4 7 5144.0 12002 80 14.57 3711 4326 9.94 / 1174.61 2 47
5 13 4252.9 12206 80 14.53 3149 3660 13.60 / 1178.27 2 51
6 13 3021.8 12470 80 14.68 2373 2787 16.39 / 1181.06 2 53
7 13 1992.7 12668 80 14.80 1755 2078 18.47 / 1183.14 2 52
8 13 1248.1 12788 80 14.89 1280 1525 19.99 / 1184.66 2 51
9 13 752.0 12857 80 14.94 951 1137 21.13 / 1185.80 2 46
10 14 0.3 12950 108 15.03 418 679 21.81 / 1186.48 2 111
Average= 19.14
(KJ/cycle)

Cycle 60 GMT 27/ 7/2024 2: 4: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.5 8 79 15.02 465 552 0.55 / 1143.26 2 12
2 6 5801.1 711 81 14.36 4094 4762 5.31 / 1148.02 2 40
3 3 5315.7 892 6 14.59 3863 338 5.65 / 1148.36 2 43
4 7 5135.9 12002 80 14.57 3700 4313 9.96 / 1152.68 2 47
5 13 4281.0 12200 80 14.52 3178 3692 13.66 / 1156.37 2 50
6 13 3168.8 12428 80 14.63 2501 2927 16.58 / 1159.29 2 52
7 13 1992.6 12650 80 14.80 1762 2086 18.67 / 1161.38 2 51
8 13 1201.1 12782 80 14.90 1253 1494 20.16 / 1162.87 2 50
9 13 723.4 12849 80 14.95 930 1112 21.28 / 1163.99 2 46
10 14 0.4 12941 108 15.04 420 682 21.96 / 1164.67 2 108
Average= 19.09
(KJ/cycle)

Cycle 59 GMT 17/ 7/2024 5:17: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.4 8 79 14.99 451 534 0.53 / 1121.59 2 12
2 6 5801.8 705 82 14.36 4080 4804 5.34 / 1126.39 2 40
3 3 5293.2 886 5 14.61 3878 283 5.62 / 1126.68 2 42
4 7 5132.7 12002 80 14.58 3681 4294 9.92 / 1130.97 2 47
5 13 4166.3 12230 80 14.54 3109 3616 13.53 / 1134.59 2 51
6 13 3012.9 12476 80 14.67 2400 2817 16.35 / 1137.40 2 52
7 13 1977.4 12680 80 14.81 1751 2075 18.42 / 1139.48 2 51
8 13 1097.9 12830 80 14.93 1189 1420 19.84 / 1140.90 2 50
9 13 741.6 12881 80 14.95 945 1130 20.97 / 1142.03 2 47
10 14 0.2 12973 108 15.04 420 682 21.66 / 1142.71 2 111
Average= 19.05
(KJ/cycle)

Cycle 58 GMT 7/ 7/2024 8: 6: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.6 8 79 14.99 454 538 0.54 / 1098.82 2 12
2 6 5807.0 707 81 14.37 4074 4742 5.28 / 1103.56 2 42
3 3 5315.5 888 6 14.60 3856 338 5.62 / 1103.90 2 43
4 7 5146.1 12002 80 14.58 3684 4297 9.91 / 1108.19 2 47
5 13 4211.4 12224 80 14.54 3116 3625 13.54 / 1111.82 2 51
6 13 2962.8 12488 80 14.68 2371 2785 16.32 / 1114.60 2 52
7 13 1978.6 12680 80 14.81 1756 2081 18.40 / 1116.68 2 50
8 13 1278.9 12794 80 14.89 1301 1550 19.95 / 1118.23 2 52
9 13 748.8 12866 80 14.96 940 1125 21.08 / 1119.36 2 46
10 13 708.6 12870 80 14.90 905 1079 22.16 / 1120.44 2 86
11 14 0.3 12944 54 15.02 418 339 22.50 / 1120.78 2 110
12 14 0.4 12944 46 15.00 405 279 22.78 / 1121.06 22 246
Average= 19.00
(KJ/cycle)

Cycle 57 GMT 27/ 6/2024 11:21: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.4 8 78 15.02 460 539 0.54 / 1075.89 2 12
2 6 5959.8 754 82 14.34 4195 4933 5.47 / 1080.82 2 40
3 3 5407.6 935 12 14.58 3881 679 6.15 / 1081.50 2 43
4 7 5038.5 12183 80 14.59 3640 4249 10.40 / 1085.75 2 50
5 13 4026.4 12429 80 14.57 3019 3519 13.92 / 1089.26 2 53
6 13 2856.3 12687 80 14.70 2286 2688 16.61 / 1091.95 2 51
7 13 1989.2 12849 80 14.80 1741 2061 18.67 / 1094.01 2 51
8 13 1173.0 12981 80 14.91 1230 1467 20.14 / 1095.48 2 51
9 13 735.9 13041 80 14.96 928 1111 21.25 / 1096.59 2 48
10 13 694.4 13045 80 14.90 895 1067 22.31 / 1097.66 2 136
11 14 0.9 13114 50 15.02 426 320 22.63 / 1097.98 2 111
12 14 0.8 13115 50 15.00 401 301 22.93 / 1098.28 23 246
Average= 18.94
(KJ/cycle)

Cycle 56 GMT 17/ 6/2024 13:57: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.1 8 78 15.02 464 544 0.54 / 1054.12 2 13
2 6 5876.8 724 82 14.35 4152 4886 5.43 / 1059.01 2 41
3 3 5345.8 905 8 14.60 3875 453 5.88 / 1059.46 2 43
4 7 5101.1 12002 80 14.58 3681 4294 10.18 / 1063.75 2 47
5 13 4200.5 12206 80 14.54 3123 3633 13.81 / 1067.38 2 50
6 13 2872.3 12494 80 14.71 2309 2717 16.53 / 1070.10 2 52
7 13 1994.7 12668 80 14.81 1756 2081 18.61 / 1072.18 2 51
8 13 980.2 12836 80 14.96 1106 1324 19.93 / 1073.51 2 49
9 13 749.2 12869 80 14.95 946 1131 21.06 / 1074.64 2 48
10 14 0.3 12963 112 15.04 421 709 21.77 / 1075.35 2 110
Average= 18.87
(KJ/cycle)

Cycle 55 GMT 7/ 6/2024 16:34: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.0 8 78 15.00 462 541 0.54 / 1032.50 2 11
2 6 5877.5 735 82 14.36 4128 4861 5.40 / 1037.36 2 40
3 3 5354.2 916 8 14.60 3870 452 5.85 / 1037.81 2 41
4 7 5102.6 12183 80 14.59 3660 4272 10.13 / 1042.09 2 47
5 13 4064.2 12435 80 14.57 3026 3527 13.65 / 1045.61 2 52
6 13 2907.7 12681 80 14.70 2317 2725 16.38 / 1048.34 2 51
7 13 1979.6 12861 80 14.81 1744 2066 18.44 / 1050.40 2 50
8 13 1135.5 12999 80 14.92 1203 1436 19.88 / 1051.84 2 50
9 13 729.2 13055 80 14.96 926 1108 20.99 / 1052.95 2 47
10 14 0.3 13146 99 15.04 417 621 21.61 / 1053.57 2 104
11 14 0.4 13146 1 15.03 429 6 21.61 / 1053.58 18 45
Average= 18.81
(KJ/cycle)

Cycle 54 GMT 28/ 5/2024 18:59: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.6 8 78 15.03 467 547 0.55 / 1009.55 2 10
2 6 5874.1 716 82 14.36 4150 4887 5.43 / 1014.43 2 41
3 3 5337.9 897 8 14.60 3891 454 5.89 / 1014.89 2 43
4 7 5102.5 12002 80 14.59 3678 4293 10.18 / 1019.18 2 47
5 13 4101.3 12230 80 14.57 3061 3568 13.75 / 1022.75 2 51
6 13 3035.7 12452 80 14.68 2405 2824 16.57 / 1025.57 2 52
7 13 1988.3 12650 80 14.81 1754 2078 18.65 / 1027.65 2 51
8 13 1166.2 12788 80 14.92 1229 1467 20.12 / 1029.12 2 50
9 13 746.7 12847 80 14.96 944 1130 21.25 / 1030.25 2 46
10 13 707.1 12851 80 14.91 910 1085 22.33 / 1031.33 2 92
11 14 0.9 12922 52 15.02 430 336 22.67 / 1031.67 2 102
12 14 1.1 12923 48 15.00 405 292 22.96 / 1031.96 23 246
Average= 18.76
(KJ/cycle)

Cycle 53 GMT 18/ 5/2024 22:26: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.9 8 79 15.03 453 538 0.54 / 987.81 2 10
2 6 5818.7 708 81 14.37 4106 4779 5.32 / 992.59 2 41
3 3 5297.4 889 5 14.63 3944 289 5.61 / 992.88 2 41
4 7 5141.5 12002 80 14.58 3707 4324 9.93 / 997.20 2 47
5 13 4239.7 12218 80 14.55 3150 3667 13.60 / 1000.87 2 50
6 13 2962.9 12488 80 14.70 2365 2781 16.38 / 1003.65 2 53
7 13 1993.3 12674 80 14.82 1769 2097 18.47 / 1005.75 2 51
8 13 1101.9 12824 80 14.94 1192 1425 19.90 / 1007.17 2 49
9 13 740.3 12875 80 14.96 942 1127 21.03 / 1008.30 2 48
10 14 0.8 12967 110 15.05 423 700 21.73 / 1009.00 2 111
Average= 18.69
(KJ/cycle)

Cycle 52 GMT 9/ 5/2024 1:16: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.9 8 78 15.03 460 539 0.54 / 965.85 2 9
2 6 5857.8 718 82 14.37 4114 4848 5.39 / 970.70 2 40
3 3 5315.2 899 6 14.61 3832 336 5.72 / 971.04 2 43
4 7 5141.8 12002 80 14.59 3686 4302 10.03 / 975.34 2 46
5 13 4233.5 12206 80 14.55 3127 3640 13.67 / 978.98 2 49
6 13 3155.7 12422 80 14.66 2489 2919 16.58 / 981.90 2 52
7 13 1987.0 12644 80 14.82 1752 2077 18.66 / 983.98 2 51
8 13 1144.7 12788 80 14.94 1218 1456 20.12 / 985.43 2 50
9 13 748.5 12845 80 14.96 944 1130 21.25 / 986.56 2 48
10 14 0.3 12941 114 15.05 415 712 21.96 / 987.27 2 107
Average= 18.63
(KJ/cycle)

Cycle 51 GMT 29/ 4/2024 4:22: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.6 8 79 15.01 453 537 0.54 / 944.14 2 10
2 6 5877.6 730 81 14.36 4150 4827 5.36 / 948.96 2 41
3 3 5364.9 911 9 14.60 3898 512 5.88 / 949.48 2 43
4 7 5084.8 12002 80 14.59 3671 4285 10.16 / 953.76 2 47
5 13 4080.0 12242 80 14.57 3046 3550 13.71 / 957.31 2 52
6 13 2906.4 12494 80 14.71 2325 2736 16.45 / 960.05 2 53
7 13 1983.7 12668 80 14.82 1743 2067 18.51 / 962.11 2 51
8 13 1056.6 12824 80 14.95 1158 1385 19.90 / 963.50 2 49
9 13 731.5 12869 80 14.97 938 1123 21.02 / 964.62 2 48
10 14 0.4 12960 108 15.05 425 691 21.71 / 965.31 2 105
Average= 18.56
(KJ/cycle)

Cycle 50 GMT 19/ 4/2024 6:59: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 51.5 6 79 15.04 451 536 0.54 / 921.37 2 8
2 6 5912.4 726 81 14.36 4167 4847 5.38 / 926.22 2 41
3 3 5332.3 907 7 14.62 3858 395 5.78 / 926.61 2 42
4 7 5125.7 12002 80 14.59 3700 4319 10.10 / 930.93 2 47
5 13 4182.1 12224 80 14.56 3113 3626 13.72 / 934.56 2 50
6 13 2947.9 12494 80 14.71 2360 2777 16.50 / 937.33 2 54
7 13 1995.2 12680 80 14.83 1754 2081 18.58 / 939.41 2 53
8 13 990.4 12854 80 14.98 1113 1334 19.91 / 940.75 2 47
9 13 747.1 12888 80 14.97 950 1138 21.05 / 941.89 2 47
10 13 709.6 12892 80 14.92 912 1089 22.14 / 942.97 2 96
11 14 1.4 12966 54 15.04 429 348 22.49 / 943.32 2 108
12 14 1.6 12966 46 15.02 401 277 22.77 / 943.60 23 246
Average= 18.50
(KJ/cycle)

Cycle 49 GMT 9/ 4/2024 9:30: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.1 8 78 15.04 463 543 0.54 / 899.39 2 8
2 6 5911.6 737 82 14.37 4162 4904 5.45 / 904.29 2 40
3 3 5363.3 918 9 14.60 3858 507 5.95 / 904.80 2 41
4 7 5089.9 12183 80 14.60 3680 4298 10.25 / 909.09 2 46
5 13 4156.4 12405 80 14.57 3094 3606 13.86 / 912.70 2 51
6 13 2972.6 12645 80 14.70 2366 2782 16.64 / 915.48 2 52
7 13 1983.9 12837 80 14.83 1757 2085 18.73 / 917.57 2 51
8 13 1105.6 12981 80 14.94 1196 1429 20.16 / 919.00 2 49
9 13 728.0 13031 80 14.97 937 1122 21.28 / 920.12 2 46
10 14 0.8 13123 112 15.05 424 715 21.99 / 920.83 2 109
Average= 18.42
(KJ/cycle)

Cycle 48 GMT 30/ 3/2024 12:16: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 71.6 8 79 15.02 449 533 0.53 / 877.56 2 9
2 6 5970.8 751 82 14.36 4195 4940 5.47 / 882.50 2 41
3 3 5385.5 932 10 14.60 3918 572 6.04 / 883.07 2 43
4 7 5042.4 12183 80 14.61 3644 4259 10.30 / 887.33 2 47
5 13 4034.3 12411 80 14.59 3032 3539 13.84 / 890.87 2 51
6 13 2848.2 12669 80 14.73 2294 2703 16.55 / 893.58 2 53
7 13 1999.5 12831 80 14.82 1762 2089 18.63 / 895.66 2 50
8 13 1042.9 12987 80 14.96 1148 1374 20.01 / 897.04 2 48
9 13 722.7 13030 80 14.97 933 1117 21.13 / 898.16 2 46
10 14 0.5 13119 108 15.06 422 686 21.81 / 898.84 2 106
Average= 18.34
(KJ/cycle)

Cycle 47 GMT 20/ 3/2024 14:53: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.1 8 78 15.03 445 522 0.52 / 855.06 2 7
2 6 5886.5 727 82 14.38 4153 4897 5.42 / 859.96 2 41
3 3 5376.3 908 10 14.61 3850 562 5.98 / 860.52 2 42
4 7 5093.8 12002 80 14.61 3659 4277 10.26 / 864.80 2 47
5 13 4158.3 12218 80 14.58 3093 3608 13.87 / 868.41 2 51
6 13 2901.0 12494 80 14.73 2319 2733 16.60 / 871.14 2 52
7 13 1988.1 12668 80 14.83 1762 2090 18.69 / 873.23 2 50
8 13 1250.9 12788 80 14.92 1279 1527 20.22 / 874.76 2 52
9 13 739.7 12857 80 14.97 940 1126 21.34 / 875.88 2 48
10 13 43.7 12940 80 15.05 450 542 21.88 / 876.42 2 55
11 14 0.9 12950 52 15.05 417 326 22.21 / 876.75 2 113
12 14 1.1 12950 48 15.03 388 280 22.49 / 877.03 27 246
Average= 18.27
(KJ/cycle)

Cycle 46 GMT 10/ 3/2024 17:38: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.5 8 79 15.05 447 531 0.53 / 832.57 2 8
2 6 6005.3 761 82 14.36 4221 4970 5.50 / 837.54 2 41
3 3 5383.3 942 10 14.61 3895 569 6.07 / 838.11 2 42
4 7 5052.1 12183 80 14.60 3652 4266 10.34 / 842.37 2 47
5 13 4112.8 12399 80 14.59 3053 3563 13.90 / 845.93 2 51
6 13 2793.0 12687 80 14.75 2268 2676 16.58 / 848.61 2 53
7 13 1979.0 12849 80 14.84 1753 2081 18.66 / 850.69 2 50
8 13 1255.9 12969 80 14.92 1300 1552 20.21 / 852.24 2 50
9 13 748.0 13037 80 14.97 950 1138 21.35 / 853.38 2 48
10 13 44.6 13121 80 15.05 458 551 21.90 / 853.93 2 63
11 14 0.9 13133 52 15.05 418 327 22.23 / 854.26 2 120
12 14 1.0 13133 48 15.03 389 281 22.51 / 854.54 28 246
Average= 18.18
(KJ/cycle)

Cycle 45 GMT 29/ 2/2024 19:50: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.3 8 79 15.01 454 538 0.54 / 810.62 2 8
2 6 6007.6 779 82 14.37 4221 4974 5.51 / 815.59 2 41
3 3 5407.9 960 12 14.59 3901 683 6.20 / 816.27 2 43
4 7 5030.5 12183 80 14.62 3630 4246 10.44 / 820.52 2 48
5 13 4120.3 12393 80 14.59 3075 3589 14.03 / 824.11 2 51
6 13 2849.1 12669 80 14.74 2283 2692 16.72 / 826.80 2 53
7 13 1993.9 12831 80 14.84 1747 2074 18.80 / 828.87 2 51
8 13 1034.3 12993 80 14.98 1138 1364 20.16 / 830.24 2 48
9 13 749.3 13031 80 14.98 946 1134 21.29 / 831.37 2 48
10 14 0.1 13126 105 15.07 419 663 21.96 / 832.03 2 101
Average= 18.09
(KJ/cycle)

Cycle 44 GMT 19/ 2/2024 21:53: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.9 8 79 15.05 454 540 0.54 / 787.59 2 8
2 6 6007.8 757 82 14.37 4221 4974 5.51 / 792.57 2 41
3 3 5429.6 938 13 14.58 3912 741 6.26 / 793.31 2 43
4 7 5017.0 12183 80 14.62 3631 4247 10.50 / 797.56 2 48
5 13 3981.6 12429 80 14.61 2987 3491 13.99 / 801.05 2 52
6 13 2871.7 12669 80 14.73 2319 2733 16.73 / 803.78 2 53
7 13 1985.8 12831 80 14.83 1755 2082 18.81 / 805.86 2 51
8 13 1054.5 12981 80 14.97 1152 1380 20.19 / 807.24 2 49
9 13 750.3 13023 80 14.98 945 1132 21.32 / 808.37 2 48
10 13 712.4 13027 80 14.93 906 1082 22.40 / 809.46 2 106
11 14 1.3 13100 54 15.04 430 349 22.75 / 809.81 2 119
12 14 1.4 13101 46 15.02 395 273 23.02 / 810.08 27 246
Average= 18.00
(KJ/cycle)

Cycle 43 GMT 10/ 2/2024 0:42: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.2 8 79 15.05 451 536 0.54 / 765.66 2 10
2 6 6008.3 763 82 14.37 4206 4956 5.49 / 770.61 2 39
3 3 5423.1 944 13 14.60 3904 741 6.23 / 771.36 2 42
4 7 5007.2 12183 80 14.63 3602 4216 10.45 / 775.57 2 47
5 13 4014.4 12417 80 14.61 3007 3515 13.96 / 779.09 2 51
6 13 2835.4 12681 80 14.75 2275 2684 16.65 / 781.77 2 53
7 13 1982.2 12837 80 14.84 1761 2091 18.74 / 783.86 2 53
8 13 1037.8 12993 80 14.97 1155 1383 20.12 / 785.24 2 49
9 13 747.9 13031 80 14.98 952 1141 21.26 / 786.39 2 48
10 14 1.1 13125 105 15.06 423 669 21.93 / 787.05 2 106
Average= 17.89
(KJ/cycle)

Cycle 42 GMT 31/ 1/2024 3: 1: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 68.5 8 79 15.05 466 554 0.55 / 743.65 2 10
2 6 6007.0 778 81 14.37 4231 4925 5.48 / 748.58 2 41
3 3 5394.1 959 11 14.60 3882 623 6.10 / 749.20 2 42
4 7 5053.4 12183 80 14.63 3638 4258 10.36 / 753.46 2 47
5 13 4158.5 12381 80 14.60 3089 3608 13.97 / 757.07 2 51
6 13 2978.9 12627 80 14.73 2367 2789 16.76 / 759.86 2 53
7 13 1992.0 12813 80 14.85 1752 2081 18.84 / 761.94 2 51
8 13 1081.1 12963 80 14.97 1174 1406 20.24 / 763.34 2 50
9 13 712.6 13013 80 15.00 919 1103 21.35 / 764.45 2 47
10 14 0.8 13103 108 15.07 415 675 22.02 / 765.12 2 102
Average= 17.79
(KJ/cycle)

Cycle 41 GMT 21/ 1/2024 5:22: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.4 8 79 15.03 457 543 0.54 / 721.70 2 8
2 6 6005.0 774 82 14.38 4234 4993 5.54 / 726.69 2 41
3 3 5403.7 955 11 14.61 3898 626 6.16 / 727.32 2 43
4 7 5037.3 12183 80 14.63 3642 4263 10.42 / 731.58 2 47
5 13 4074.2 12411 80 14.62 3044 3560 13.98 / 735.14 2 51
6 13 2955.5 12639 80 14.73 2360 2781 16.77 / 737.92 2 52
7 13 1999.3 12813 80 14.84 1757 2086 18.85 / 740.00 2 51
8 13 964.2 12987 80 15.00 1097 1316 20.17 / 741.32 2 49
9 13 729.6 13019 80 14.99 939 1126 21.29 / 742.45 2 48
10 14 0.6 13110 103 15.07 420 652 21.95 / 743.10 2 104
Average= 17.69
(KJ/cycle)

Cycle 40 GMT 11/ 1/2024 7:45: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.7 8 80 15.05 460 554 0.55 / 698.70 2 9
2 6 6004.3 756 81 14.38 4225 4921 5.48 / 703.62 2 41
3 3 5405.4 937 12 14.59 3890 681 6.16 / 704.30 2 42
4 7 5031.3 12183 80 14.63 3635 4254 10.41 / 708.55 2 48
5 13 4153.0 12381 80 14.61 3095 3617 14.03 / 712.17 2 51
6 13 2805.5 12663 80 14.76 2283 2696 16.72 / 714.87 2 54
7 13 1988.4 12825 80 14.85 1762 2093 18.82 / 716.96 2 50
8 13 967.3 12993 80 15.00 1108 1330 20.15 / 718.29 2 49
9 13 750.3 13023 80 14.99 946 1134 21.28 / 719.42 2 48
10 13 710.9 13027 80 14.94 917 1096 22.38 / 720.52 2 101
11 14 1.5 13101 52 15.05 432 338 22.72 / 720.86 2 103
12 14 1.6 13102 48 15.03 411 297 23.01 / 721.15 26 246
Average= 17.59
(KJ/cycle)

Cycle 39 GMT 1/ 1/2024 10:33: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 66.5 8 79 15.06 466 554 0.55 / 676.54 2 10
2 6 6007.7 755 82 14.38 4228 4985 5.54 / 681.53 2 40
3 3 5390.3 936 11 14.60 3887 624 6.16 / 682.15 2 41
4 7 5073.1 12183 80 14.64 3654 4280 10.44 / 686.43 2 48
5 13 4043.3 12429 80 14.63 3036 3553 14.00 / 689.98 2 50
6 13 2929.0 12663 80 14.74 2362 2785 16.78 / 692.77 2 53
7 13 1980.3 12843 80 14.85 1753 2083 18.86 / 694.85 2 51
8 13 1187.6 12969 80 14.95 1253 1499 20.36 / 696.35 2 50
9 13 721.4 13031 80 14.99 941 1128 21.49 / 697.48 2 47
10 14 1.4 13123 103 15.07 427 663 22.15 / 698.14 2 104
Average= 17.45
(KJ/cycle)

Cycle 38 GMT 22/12/2023 13: 1: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.2 8 90 15.05 458 620 0.62 / 655.60 2 9
2 6 5808.2 744 81 14.40 4119 4804 5.42 / 660.41 2 41
3 3 5222.1 925 12 14.62 3823 671 6.10 / 661.08 2 42
4 7 4806.3 12183 80 14.67 3511 4121 10.22 / 665.20 2 49
5 13 3788.7 12435 80 14.67 2893 3395 13.61 / 668.59 2 52
6 13 2634.8 12687 80 14.80 2181 2582 16.19 / 671.18 2 52
7 13 1973.8 12807 80 14.85 1754 2084 18.28 / 673.26 2 51
8 13 746.5 13007 80 15.04 960 1155 19.43 / 674.41 2 46
9 13 491.3 13043 80 15.03 778 935 20.37 / 675.35 2 44
10 14 1.0 13105 93 15.08 423 593 20.96 / 675.94 2 106
11 14 1.2 13105 7 15.07 414 44 21.00 / 675.99 16 66
Average= 17.33
(KJ/cycle)

Cycle 37 GMT 12/12/2023 15:58: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.1 8 90 15.06 468 634 0.63 / 634.20 2 10
2 6 5807.3 743 81 14.41 4121 4810 5.44 / 639.01 2 42
3 3 5235.1 924 13 14.62 3801 722 6.17 / 639.73 2 43
4 7 4811.2 12183 80 14.67 3522 4133 10.30 / 643.86 2 48
5 13 3807.7 12423 80 14.67 2896 3399 13.70 / 647.26 2 51
6 13 2608.5 12687 80 14.81 2148 2545 16.24 / 649.81 2 52
7 13 1974.4 12801 80 14.85 1762 2093 18.34 / 651.90 2 50
8 13 905.7 12969 80 15.01 1076 1292 19.63 / 653.19 2 48
9 13 749.0 12989 80 14.99 958 1149 20.78 / 654.34 2 51
10 14 0.8 13079 93 15.08 425 596 21.37 / 654.94 2 108
11 14 0.8 13079 7 15.07 421 44 21.42 / 654.98 20 62
Average= 17.24
(KJ/cycle)

Cycle 36 GMT 2/12/2023 19:21: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.6 8 90 15.07 462 627 0.63 / 612.83 2 11
2 6 5807.4 744 81 14.40 4130 4817 5.44 / 617.64 2 42
3 3 5172.2 925 9 14.65 3765 496 5.94 / 618.14 2 43
4 7 4864.9 12183 80 14.67 3557 4174 10.11 / 622.32 2 48
5 13 3844.6 12423 80 14.67 2924 3432 13.55 / 625.75 2 51
6 13 2689.6 12693 80 14.80 2203 2608 16.15 / 628.36 2 52
7 13 1989.1 12819 80 14.85 1770 2103 18.26 / 630.46 2 52
8 13 949.3 12981 80 15.01 1093 1312 19.57 / 631.77 2 48
9 13 721.9 13012 80 15.00 946 1135 20.71 / 632.91 2 47
10 14 0.9 13099 95 15.08 437 626 21.33 / 633.53 2 111
11 14 1.1 13099 5 15.07 427 32 21.36 / 633.56 14 63
Average= 17.12
(KJ/cycle)

Cycle 35 GMT 22/11/2023 22:23:59

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.8 8 90 15.07 463 628 0.63 / 591.81 2 12
2 6 5804.9 740 81 14.40 4124 4810 5.44 / 596.62 2 41
3 3 5220.8 921 12 14.62 3826 671 6.11 / 597.29 2 42
4 7 4814.5 12183 80 14.68 3509 4121 10.23 / 601.41 2 49
5 13 4025.0 12351 80 14.65 3033 3555 13.79 / 604.97 2 52
6 13 2640.3 12639 80 14.81 2182 2585 16.37 / 607.55 2 52
7 13 1899.9 12777 80 14.88 1712 2038 18.41 / 609.59 2 50
8 13 755.7 12965 80 15.06 962 1159 19.57 / 610.75 2 44
9 13 326.8 13025 80 15.07 668 805 20.37 / 611.55 2 36
10 14 0.6 13069 90 15.09 429 583 20.96 / 612.14 2 107
11 14 0.8 13069 10 15.08 425 64 21.02 / 612.20 21 77
Average= 17.01
(KJ/cycle)

Cycle 34 GMT 13/11/2023 2: 2: 3

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.1 8 89 15.08 466 625 0.63 / 570.39 2 10
2 6 5807.8 750 82 14.42 4131 4885 5.51 / 575.27 2 41
3 3 5237.7 931 13 14.62 3800 722 6.23 / 575.99 2 43
4 7 4812.4 12183 80 14.68 3534 4150 10.38 / 580.14 2 47
5 13 3871.3 12405 80 14.68 2950 3464 13.85 / 583.61 2 52
6 13 2619.1 12675 80 14.82 2167 2569 16.42 / 586.18 2 52
7 13 1862.7 12813 80 14.89 1691 2014 18.43 / 588.19 2 51
8 13 774.4 12993 80 15.06 985 1187 19.62 / 589.38 2 46
9 13 722.8 12999 80 15.01 951 1142 20.76 / 590.52 2 48
10 14 0.9 13083 93 15.09 438 615 21.37 / 591.14 2 103
11 14 0.9 13084 7 15.08 430 45 21.42 / 591.18 20 72
Average= 16.89
(KJ/cycle)

Cycle 33 GMT 3/11/2023 5: 9: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.5 8 90 15.08 466 632 0.63 / 549.45 2 12
2 6 5807.6 734 81 14.41 4119 4808 5.44 / 554.26 2 41
3 3 5168.3 915 9 14.65 3788 499 5.94 / 554.76 2 42
4 7 4876.6 12183 80 14.69 3572 4198 10.14 / 558.96 2 48
5 13 3931.3 12399 80 14.68 2963 3480 13.62 / 562.44 2 51
6 13 2695.5 12669 80 14.82 2213 2624 16.24 / 565.06 2 52
7 13 2000.5 12789 80 14.86 1775 2110 18.35 / 567.17 2 50
8 13 743.5 12995 80 15.06 969 1167 19.52 / 568.34 2 45
9 13 271.3 13061 80 15.08 634 765 20.28 / 569.10 2 36
10 14 0.8 13099 90 15.10 438 595 20.88 / 569.70 2 103
11 14 0.9 13099 10 15.09 433 65 20.94 / 569.76 23 81
Average= 16.76
(KJ/cycle)

Cycle 32 GMT 24/10/2023 8:19: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.4 8 89 15.08 473 635 0.63 / 528.45 2 13
2 6 5808.3 739 81 14.41 4124 4814 5.45 / 533.26 2 41
3 3 5213.4 920 12 14.64 3802 668 6.12 / 533.93 2 42
4 7 4849.0 12183 80 14.70 3530 4151 10.27 / 538.08 2 48
5 13 3777.7 12435 80 14.71 2882 3392 13.66 / 541.47 2 51
6 13 2738.6 12663 80 14.81 2241 2655 16.31 / 544.13 2 52
7 13 1991.5 12801 80 14.87 1781 2119 18.43 / 546.25 2 51
8 13 741.6 13007 80 15.07 967 1166 19.60 / 547.41 2 43
9 13 267.0 13073 80 15.09 627 757 20.36 / 548.17 2 33
10 14 0.5 13111 88 15.11 429 570 20.93 / 548.74 2 106
11 14 0.5 13111 12 15.10 426 77 21.00 / 548.82 21 94
Average= 16.63
(KJ/cycle)

Cycle 31 GMT 14/10/2023 11:16: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.5 8 90 15.08 477 647 0.65 / 507.60 2 13
2 6 5807.1 745 81 14.41 4139 4831 5.48 / 512.43 2 41
3 3 5209.7 926 12 14.63 3813 669 6.15 / 513.10 2 42
4 7 4808.6 12183 80 14.70 3526 4147 10.29 / 517.24 2 48
5 13 3774.3 12429 80 14.71 2895 3407 13.70 / 520.65 2 52
6 13 2603.0 12681 80 14.84 2167 2573 16.27 / 523.22 2 52
7 13 1955.5 12795 80 14.88 1749 2082 18.36 / 525.30 2 51
8 13 752.4 12989 80 15.07 968 1167 19.52 / 526.47 2 45
9 13 183.9 13067 80 15.10 571 690 20.21 / 527.16 2 31
10 14 0.3 13094 82 15.11 434 538 20.75 / 527.70 2 103
11 14 0.4 13095 18 15.09 428 116 20.87 / 527.81 16 134
Average= 16.49
(KJ/cycle)

Cycle 30 GMT 4/10/2023 14:21: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.0 8 89 15.08 480 644 0.64 / 486.07 2 14
2 6 5807.5 738 81 14.42 4131 4825 5.47 / 490.90 2 41
3 3 5229.5 919 13 14.64 3817 726 6.20 / 491.62 2 44
4 7 4839.1 12183 80 14.71 3547 4174 10.37 / 495.80 2 49
5 13 3814.4 12411 80 14.71 2913 3428 13.80 / 499.23 2 52
6 13 2615.9 12675 80 14.84 2174 2581 16.38 / 501.81 2 53
7 13 1846.2 12813 80 14.91 1684 2009 18.39 / 503.82 2 52
8 13 949.7 12963 80 15.04 1096 1319 19.71 / 505.13 2 48
9 13 746.8 12989 80 15.02 961 1155 20.86 / 506.29 2 50
10 14 0.3 13077 86 15.10 437 567 21.43 / 506.86 2 113
11 14 0.4 13077 14 15.09 434 92 21.52 / 506.95 19 123
Average= 16.35
(KJ/cycle)

Cycle 29 GMT 24/ 9/2023 17:49: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.2 8 89 15.08 481 646 0.65 / 464.33 2 13
2 6 5808.2 745 82 14.42 4145 4901 5.55 / 469.23 2 40
3 3 5233.9 926 13 14.63 3828 728 6.27 / 469.95 2 43
4 7 4804.1 12183 80 14.72 3523 4149 10.42 / 474.10 2 47
5 13 3908.0 12375 80 14.71 2962 3486 13.91 / 477.59 2 51
6 13 2636.2 12645 80 14.84 2186 2595 16.50 / 480.18 2 52
7 13 1964.0 12771 80 14.89 1767 2105 18.61 / 482.29 2 51
8 13 929.4 12933 80 15.04 1099 1322 19.93 / 483.61 2 48
9 13 728.6 12959 80 15.03 952 1145 21.08 / 484.76 2 50
10 14 0.6 13043 84 15.11 445 565 21.64 / 485.32 2 107
11 14 0.7 13044 16 15.09 443 107 21.75 / 485.43 18 137
Average= 16.18
(KJ/cycle)

Cycle 28 GMT 14/ 9/2023 21:45: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.8 8 103 15.08 486 755 0.75 / 443.84 2 14
2 6 5504.9 677 81 14.46 3964 4643 5.40 / 448.48 2 42
3 3 4927.2 858 13 14.67 3610 688 6.09 / 449.17 2 44
4 7 4506.9 12002 80 14.76 3350 3956 10.04 / 453.13 2 50
5 13 3551.3 12218 80 14.76 2771 3272 13.31 / 456.40 2 53
6 13 2378.8 12458 80 14.88 2033 2420 15.73 / 458.82 2 53
7 13 1635.2 12584 80 14.95 1567 1874 17.61 / 460.69 2 51
8 13 747.3 12722 80 15.08 972 1173 18.78 / 461.86 2 48
9 13 713.8 12726 80 15.02 947 1138 19.92 / 463.00 2 56
10 14 0.6 12806 71 15.11 451 484 20.40 / 463.49 2 105
11 14 0.6 12806 29 15.09 441 193 20.60 / 463.68 17 238
Average= 15.99
(KJ/cycle)

Cycle 27 GMT 5/ 9/2023 3:47: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.7 8 103 15.08 477 741 0.74 / 423.23 2 14
2 6 5507.8 709 80 14.47 3967 4592 5.33 / 427.83 2 42
3 3 4876.5 890 10 14.69 3640 535 5.87 / 428.36 2 43
4 7 4575.9 12002 80 14.76 3393 4006 9.87 / 432.37 2 49
5 13 3703.6 12194 80 14.75 2845 3357 13.23 / 435.73 2 53
6 13 2327.1 12488 80 14.90 1995 2378 15.61 / 438.10 2 53
7 13 1785.6 12584 80 14.93 1654 1976 17.58 / 440.08 2 51
8 13 749.6 12740 80 15.08 980 1182 18.77 / 441.26 2 46
9 13 716.1 12744 80 15.03 948 1140 19.91 / 442.40 2 52
10 14 0.7 12822 75 15.11 454 514 20.42 / 442.92 2 110
11 14 1.0 12822 25 15.09 447 169 20.59 / 443.08 24 208
Average= 15.82
(KJ/cycle)

Cycle 26 GMT 26/ 8/2023 9: 0: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.2 8 102 15.09 477 734 0.73 / 402.63 2 14
2 6 5505.3 721 80 14.47 3980 4607 5.34 / 407.24 2 42
3 3 4810.7 902 6 14.72 3616 319 5.66 / 407.56 2 43
4 7 4657.2 12002 80 14.74 3465 4086 9.75 / 411.65 2 48
5 13 3733.6 12212 80 14.75 2887 3407 13.15 / 415.05 2 51
6 13 2526.3 12464 80 14.87 2133 2537 15.69 / 417.59 2 52
7 13 1685.5 12614 80 14.95 1600 1914 17.60 / 419.50 2 51
8 13 746.6 12764 80 15.09 973 1175 18.78 / 420.68 2 46
9 13 713.2 12768 80 15.03 941 1131 19.91 / 421.81 2 51
10 14 0.9 12849 78 15.12 453 534 20.44 / 422.34 2 104
11 14 1.0 12850 22 15.10 449 149 20.59 / 422.49 21 184
Average= 15.65
(KJ/cycle)

Cycle 25 GMT 16/ 8/2023 13:36: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.3 9 126 15.09 483 918 0.92 / 384.35 2 15
2 6 5009.4 657 62 14.58 3649 3299 4.22 / 387.65 2 43
3 3 4559.8 837 3 14.81 3510 156 4.37 / 387.81 2 37
4 7 4520.7 12002 80 14.77 3370 3982 8.35 / 391.79 2 48
5 13 3517.7 12230 80 14.78 2760 3263 11.62 / 395.05 2 52
6 13 2464.7 12458 80 14.88 2117 2520 14.14 / 397.57 2 52
7 13 1531.1 12620 80 14.98 1510 1810 15.95 / 399.38 2 50
8 13 746.9 12743 80 15.08 989 1193 17.14 / 400.58 2 47
9 13 95.7 12827 80 15.13 527 638 17.78 / 401.21 2 32
10 14 0.2 12843 65 15.13 458 450 18.23 / 401.66 2 105
11 14 0.2 12843 35 15.11 447 236 18.47 / 401.90 21 246
Average= 15.46
(KJ/cycle)

Cycle 24 GMT 6/ 8/2023 19:21: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.1 9 126 15.09 479 911 0.91 / 365.61 2 16
2 6 5004.5 662 62 14.58 3681 3327 4.24 / 368.94 2 43
3 3 4568.5 843 3 14.81 3583 159 4.40 / 369.10 2 36
4 7 4497.0 12002 80 14.78 3363 3976 8.37 / 373.08 2 48
5 13 3647.0 12200 80 14.77 2841 3357 11.73 / 376.44 2 52
6 13 2468.8 12434 80 14.88 2096 2495 14.23 / 378.93 2 51
7 13 1778.4 12548 80 14.93 1663 1986 16.21 / 380.92 2 50
8 13 752.1 12701 80 15.09 981 1184 17.40 / 382.10 2 46
9 13 117.2 12785 80 15.13 541 655 18.05 / 382.76 2 34
10 14 0.4 12802 65 15.13 452 445 18.50 / 383.20 2 105
11 14 0.5 12802 35 15.11 443 234 18.73 / 383.43 15 246
Average= 15.34
(KJ/cycle)

Cycle 23 GMT 28/ 7/2023 1:43: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.5 9 128 15.09 488 943 0.94 / 346.99 2 15
2 6 4854.8 628 61 14.61 3578 3189 4.13 / 350.18 2 42
3 7 4523.1 12002 80 14.78 3373 3988 8.12 / 354.16 2 49
4 13 3521.5 12236 80 14.79 2766 3273 11.39 / 357.44 2 52
5 13 2508.4 12434 80 14.88 2115 2518 13.91 / 359.95 2 52
6 13 1850.4 12548 80 14.93 1701 2032 15.94 / 361.99 2 50
7 13 755.7 12713 80 15.09 986 1190 17.13 / 363.18 2 45
8 13 342.6 12767 80 15.10 701 847 17.98 / 364.02 2 42
9 14 0.4 12807 69 15.13 455 475 18.45 / 364.50 2 111
10 14 0.5 12807 31 15.11 441 207 18.66 / 364.70 20 246
Average= 15.20
(KJ/cycle)

Cycle 22 GMT 18/ 7/2023 8:32: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.0 9 128 15.10 475 918 0.92 / 328.24 2 15
2 6 4385.9 533 78 14.63 3288 3752 4.67 / 332.00 2 45
3 7 4203.4 13076 80 14.83 3202 3799 8.47 / 335.79 2 49
4 13 3253.5 13287 80 14.84 2595 3081 11.55 / 338.87 2 52
5 13 2102.0 13533 80 14.96 1875 2244 13.79 / 341.12 2 51
6 13 1434.7 13647 80 15.01 1443 1733 15.53 / 342.85 2 49
7 13 948.3 13713 80 15.05 1115 1342 16.87 / 344.19 2 47
8 13 719.3 13739 80 15.04 959 1154 18.02 / 345.35 2 67
9 14 0.7 13813 54 15.13 469 383 18.41 / 345.73 2 104
10 14 0.9 13813 46 15.11 450 313 18.72 / 346.04 20 246
Average= 15.05
(KJ/cycle)

Cycle 21 GMT 8/ 7/2023 18: 8: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.5 9 163 15.09 478 1176 1.18 / 311.42 2 16
2 6 4406.3 655 59 14.69 3307 2866 4.04 / 314.29 2 45
3 3 3878.4 836 4 14.88 3078 183 4.23 / 314.47 2 46
4 7 3751.1 4802 80 14.90 2907 3465 7.69 / 317.94 2 50
5 13 2747.9 5030 80 14.92 2269 2708 10.40 / 320.64 2 52
6 13 1988.7 5168 80 14.97 1788 2141 12.54 / 322.79 2 52
7 13 1089.4 5312 80 15.07 1204 1452 13.99 / 324.24 2 49
8 13 872.2 5342 80 15.06 1052 1267 15.26 / 325.50 2 48
9 13 735.7 5357 80 15.03 957 1151 16.41 / 326.65 2 170
10 14 0.4 5431 43 15.14 463 301 16.71 / 326.96 2 114
11 14 0.6 5431 57 15.12 428 369 17.08 / 327.33 28 246
Average= 14.88
(KJ/cycle)

Cycle 20 GMT 4/ 7/2023 3:27: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 59.2 9 163 15.10 480 1181 1.18 / 294.24 2 16
2 6 4406.8 649 59 14.69 3308 2867 4.05 / 297.11 2 45
3 3 3902.6 830 5 14.89 3055 227 4.28 / 297.34 2 46
4 7 3725.8 4802 80 14.91 2888 3445 7.72 / 300.78 2 50
5 13 2826.1 5000 80 14.91 2320 2767 10.49 / 303.55 2 52
6 13 1999.8 5150 80 14.97 1793 2147 12.64 / 305.70 2 51
7 13 1008.8 5312 80 15.10 1156 1396 14.03 / 307.09 2 48
8 13 968.8 5318 80 15.04 1119 1346 15.38 / 308.44 2 49
9 13 709.0 5345 80 15.05 946 1139 16.52 / 309.58 2 126
10 14 0.5 5416 43 15.14 460 299 16.82 / 309.88 2 115
11 14 0.6 5417 57 15.12 425 366 17.18 / 310.25 15 246
Average= 14.77
(KJ/cycle)

Cycle 19 GMT 29/ 6/2023 13: 9: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.2 9 163 15.13 483 1191 1.19 / 277.14 2 17
2 6 4406.5 645 59 14.70 3320 2879 4.07 / 280.02 2 45
3 3 3889.1 826 4 14.88 3055 182 4.25 / 280.21 2 46
4 7 3740.7 4802 80 14.91 2893 3451 7.70 / 283.66 2 50
5 13 2832.6 5006 80 14.92 2316 2764 10.47 / 286.42 2 52
6 13 1986.9 5162 80 14.98 1792 2148 12.62 / 288.57 2 51
7 13 986.0 5324 80 15.11 1150 1390 14.01 / 289.96 2 47
8 13 858.3 5342 80 15.08 1049 1266 15.27 / 291.22 2 48
9 13 724.7 5357 80 15.05 962 1158 16.43 / 292.38 2 158
10 14 0.6 5427 43 15.15 467 304 16.73 / 292.69 2 111
11 14 0.9 5428 57 15.13 436 376 17.11 / 293.06 30 246
Average= 14.65
(KJ/cycle)

Cycle 18 GMT 24/ 6/2023 22:42: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 65.6 9 164 15.11 478 1185 1.18 / 261.20 2 15
2 6 4407.0 614 59 14.70 3327 2886 4.07 / 264.09 2 44
3 3 3863.8 795 3 14.93 3164 142 4.21 / 264.23 2 36
4 7 3746.1 4802 80 14.92 2910 3473 7.69 / 267.70 2 50
5 13 2787.5 5018 80 14.93 2297 2744 10.43 / 270.45 2 51
6 13 1997.4 5162 80 14.98 1811 2170 12.60 / 272.62 2 50
7 13 1070.4 5312 80 15.09 1212 1463 14.06 / 274.08 2 48
8 13 728.8 5357 80 15.10 973 1175 15.24 / 275.25 2 47
9 14 0.2 5444 90 15.17 461 629 15.87 / 275.88 2 101
10 14 0.4 5444 10 15.16 455 69 15.94 / 275.95 18 90
Average= 14.52
(KJ/cycle)

Cycle 17 GMT 20/ 6/2023 8:30: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.6 9 162 15.11 478 1170 1.17 / 243.90 2 16
2 6 4406.6 624 60 14.70 3318 2926 4.10 / 246.83 2 45
3 3 3912.1 805 6 14.88 3047 272 4.37 / 247.10 2 45
4 7 3708.4 4802 80 14.93 2881 3441 7.81 / 250.54 2 50
5 13 2901.5 4976 80 14.92 2363 2820 10.63 / 253.36 2 51
6 13 1941.8 5156 80 15.00 1777 2132 12.76 / 255.49 2 51
7 13 1064.7 5300 80 15.10 1201 1451 14.21 / 256.94 2 47
8 13 800.9 5336 80 15.10 1019 1231 15.44 / 258.17 2 46
9 13 720.1 5345 80 15.06 959 1155 16.60 / 259.33 2 93
10 14 0.4 5417 48 15.15 471 343 16.94 / 259.67 2 114
11 14 0.7 5418 52 15.14 440 346 17.29 / 260.02 28 246
Average= 14.45
(KJ/cycle)

Cycle 16 GMT 15/ 6/2023 18:35: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.4 9 163 15.15 478 1180 1.18 / 226.45 2 15
2 6 4407.4 626 59 14.71 3325 2886 4.07 / 229.34 2 44
3 3 3863.6 807 3 14.93 3141 141 4.21 / 229.48 2 35
4 7 3765.7 4802 80 14.93 2924 3492 7.70 / 232.97 2 50
5 13 3037.9 4952 80 14.90 2466 2939 10.64 / 235.91 2 51
6 13 1982.2 5144 80 14.99 1802 2161 12.80 / 238.07 2 50
7 13 1105.7 5282 80 15.09 1235 1491 14.29 / 239.56 2 48
8 13 880.2 5312 80 15.08 1075 1297 15.59 / 240.86 2 47
9 13 743.1 5327 80 15.06 979 1179 16.77 / 242.04 2 151
10 14 0.9 5402 45 15.16 476 325 17.09 / 242.36 2 114
11 14 1.0 5403 55 15.14 437 364 17.46 / 242.73 21 246
Average= 14.28
(KJ/cycle)

Cycle 15 GMT 11/ 6/2023 4:52: 2

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.1 9 162 15.12 480 1176 1.18 / 210.39 2 15
2 6 4404.9 636 60 14.71 3321 2931 4.11 / 213.32 2 45
3 3 3906.4 817 5 14.91 3105 231 4.34 / 213.55 2 45
4 7 3741.3 4802 80 14.93 2917 3484 7.82 / 217.03 2 51
5 13 2725.5 5048 80 14.96 2280 2729 10.55 / 219.76 2 51
6 13 1975.8 5192 80 14.99 1811 2172 12.72 / 221.93 2 51
7 13 1048.0 5342 80 15.11 1203 1454 14.18 / 223.39 2 47
8 13 737.4 5383 80 15.11 988 1194 15.37 / 224.58 2 46
9 14 0.2 5473 93 15.19 454 641 16.01 / 225.22 2 107
10 14 0.3 5473 7 15.18 461 49 16.06 / 225.27 24 79
Average= 14.08
(KJ/cycle)

Cycle 14 GMT 6/ 6/2023 13:46: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.7 9 160 15.12 483 1168 1.17 / 192.86 2 15
2 6 4403.9 630 59 14.72 3321 2884 4.05 / 195.74 2 45
3 3 3970.6 811 9 14.88 3092 414 4.47 / 196.16 2 46
4 7 3731.5 4802 80 14.94 2899 3465 7.93 / 199.62 2 50
5 13 2917.8 4976 80 14.93 2390 2855 10.79 / 202.48 2 52
6 13 1946.9 5150 80 15.01 1785 2143 12.93 / 204.62 2 50
7 13 1101.0 5288 80 15.10 1243 1502 14.43 / 206.12 2 48
8 13 786.8 5330 80 15.11 1016 1228 15.66 / 207.35 2 47
9 13 733.9 5336 80 15.06 972 1171 16.83 / 208.52 2 98
10 14 0.7 5407 48 15.16 469 341 17.17 / 208.86 2 111
11 14 0.7 5408 52 15.15 441 347 17.52 / 209.21 23 246
Average= 13.95
(KJ/cycle)

Cycle 13 GMT 1/ 6/2023 23:55: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.9 9 151 15.13 487 1113 1.11 / 174.81 2 16
2 6 4409.9 596 60 14.71 3319 2929 4.04 / 177.74 2 44
3 3 4040.1 777 13 14.85 3127 604 4.65 / 178.34 2 44
4 7 3808.9 4802 80 14.94 2958 3535 8.18 / 181.88 2 51
5 13 2970.6 4982 80 14.93 2434 2907 11.09 / 184.78 2 50
6 13 1998.4 5162 80 15.01 1811 2175 13.26 / 186.96 2 51
7 13 1038.6 5318 80 15.12 1200 1452 14.71 / 188.41 2 47
8 13 997.3 5324 80 15.06 1165 1404 16.12 / 189.81 2 49
9 13 739.6 5351 80 15.06 984 1186 17.30 / 191.00 2 135
10 14 0.6 5425 43 15.17 476 310 17.61 / 191.31 2 112
11 14 0.6 5426 57 15.15 444 383 18.00 / 191.69 25 246
Average= 13.69
(KJ/cycle)

Cycle 12 GMT 28/ 5/2023 10:19: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.3 9 151 15.13 484 1106 1.11 / 157.06 2 15
2 6 4208.5 548 70 14.72 3214 3312 4.42 / 160.37 2 44
3 3 3832.4 729 1 14.94 3119 47 4.46 / 160.42 2 34
4 7 3837.4 5892 80 14.94 2983 3565 8.03 / 163.98 2 51
5 13 2895.3 6108 80 14.94 2388 2854 10.88 / 166.84 2 50
6 13 1997.4 6276 80 15.01 1813 2177 13.06 / 169.01 2 50
7 13 988.9 6444 80 15.14 1174 1422 14.48 / 170.44 2 46
8 13 948.5 6450 80 15.08 1135 1369 15.85 / 171.81 2 48
9 13 727.0 6473 80 15.07 979 1180 17.03 / 172.99 2 134
10 14 1.2 6543 43 15.17 489 319 17.35 / 173.30 2 120
11 14 1.3 6544 57 15.15 452 390 17.74 / 173.69 23 246
Average= 13.36
(KJ/cycle)

Cycle 11 GMT 23/ 5/2023 21: 0: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.5 9 150 15.11 487 1104 1.10 / 139.26 2 14
2 6 4209.9 543 71 14.71 3200 3342 4.45 / 142.60 2 45
3 7 3859.8 5887 80 14.93 3005 3589 8.04 / 146.19 2 51
4 13 2836.8 6127 80 14.96 2361 2826 10.86 / 149.02 2 52
5 13 1988.1 6295 80 15.01 1819 2184 13.04 / 151.20 2 50
6 13 1027.5 6457 80 15.13 1202 1455 14.50 / 152.66 2 47
7 13 987.0 6463 80 15.07 1161 1400 15.90 / 154.06 2 49
8 13 739.3 6490 80 15.07 990 1194 17.09 / 155.25 2 125
9 14 1.1 6564 43 15.18 481 314 17.41 / 155.56 2 106
10 14 1.4 6565 57 15.15 450 389 17.80 / 155.95 24 246
Average= 13.00
(KJ/cycle)

Cycle 10 GMT 19/ 5/2023 7:22: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 61.4 9 157 15.11 493 1170 1.17 / 121.90 2 16
2 6 4108.9 538 70 14.73 3145 3243 4.41 / 125.14 2 43
3 7 3665.2 1562 80 14.89 2875 3425 7.84 / 128.57 2 48
4 13 2762.1 1766 80 14.92 2314 2762 10.60 / 131.33 2 51
5 13 1963.6 1916 80 14.99 1809 2169 12.77 / 133.50 2 49
6 13 1110.3 2054 80 15.09 1259 1520 14.29 / 135.02 2 47
7 13 766.6 2099 80 15.11 1017 1229 15.52 / 136.25 2 46
8 13 728.3 2103 80 15.05 992 1194 16.71 / 137.44 2 108
9 14 0.6 2177 50 15.15 491 372 17.08 / 137.81 2 114
10 14 0.7 2178 50 15.13 455 344 17.43 / 138.16 22 246
Average= 12.56
(KJ/cycle)

Cycle 9 GMT 17/ 5/2023 18:51: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.3 9 157 15.11 492 1167 1.17 / 104.21 2 15
2 6 4109.6 545 70 14.73 3155 3253 4.42 / 107.46 2 43
3 3 3757.6 726 3 14.95 3120 140 4.56 / 107.60 2 35
4 7 3651.6 1569 80 14.90 2873 3425 7.98 / 111.02 2 50
5 13 2741.2 1773 80 14.93 2305 2753 10.74 / 113.78 2 50
6 13 2000.6 1917 80 14.98 1827 2189 12.93 / 115.97 2 49
7 13 1121.5 2055 80 15.09 1273 1537 14.46 / 117.50 2 47
8 13 854.1 2091 80 15.09 1092 1318 15.78 / 118.82 2 48
9 13 720.7 2106 80 15.06 992 1195 16.98 / 120.02 2 245
10 14 0.8 2177 43 15.16 494 322 17.30 / 120.34 2 121
11 14 0.9 2178 57 15.13 454 392 17.69 / 120.73 29 246
Average= 12.07
(KJ/cycle)

Cycle 8 GMT 16/ 5/2023 6:22: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.3 9 157 15.11 495 1174 1.17 / 86.44 2 15
2 6 4099.8 533 70 14.73 3153 3251 4.43 / 89.69 2 43
3 7 3704.1 1557 80 14.89 2917 3475 7.90 / 93.17 2 48
4 13 2798.1 1768 80 14.93 2348 2804 10.70 / 95.97 2 51
5 13 1978.8 1930 80 14.99 1830 2195 12.90 / 98.17 2 50
6 13 1036.0 2080 80 15.11 1233 1490 14.39 / 99.66 2 47
7 13 997.5 2086 80 15.05 1190 1433 15.82 / 101.09 2 49
8 13 737.2 2112 80 15.05 1015 1222 17.04 / 102.31 2 151
9 14 0.8 2186 43 15.15 501 326 17.37 / 102.64 2 110
10 14 0.9 2187 57 15.14 465 401 17.77 / 103.04 23 246
Average= 11.45
(KJ/cycle)

Cycle 7 GMT 14/ 5/2023 17:44: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.3 9 160 15.14 504 1221 1.22 / 68.82 2 15
2 6 4035.4 524 70 14.75 3117 3218 4.44 / 72.04 2 42
3 7 3629.9 1548 80 14.91 2863 3415 7.85 / 75.45 2 48
4 13 2723.8 1752 80 14.94 2303 2753 10.61 / 78.21 2 51
5 13 1990.1 1884 80 14.99 1848 2216 12.82 / 80.42 2 47
6 13 1006.2 2040 80 15.12 1223 1479 14.30 / 81.90 2 46
7 13 965.7 2046 80 15.06 1173 1413 15.72 / 83.32 2 48
8 13 727.5 2070 80 15.05 1019 1227 16.94 / 84.54 2 159
9 14 0.9 2143 43 15.16 499 325 17.27 / 84.87 2 117
10 14 1.1 2144 57 15.14 462 399 17.67 / 85.27 32 246
Average= 10.66
(KJ/cycle)

Cycle 6 GMT 13/ 5/2023 5:47: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 63.5 9 166 15.11 513 1287 1.29 / 52.87 2 15
2 6 4009.0 533 65 14.76 3122 2995 4.28 / 55.87 2 43
3 3 3619.8 714 6 14.93 2972 266 4.55 / 56.13 2 44
4 7 3478.3 1557 80 14.93 2797 3341 7.89 / 59.47 2 48
5 13 2567.0 1767 80 14.96 2234 2674 10.56 / 62.15 2 51
6 13 1666.0 1935 80 15.04 1666 2005 12.57 / 64.15 2 48
7 13 981.9 2043 80 15.11 1216 1470 14.04 / 65.62 2 47
8 13 720.1 2076 80 15.11 1023 1237 15.27 / 66.86 2 46
9 14 0.5 2159 84 15.19 491 626 15.90 / 67.49 2 104
10 14 0.7 2159 16 15.17 473 115 16.01 / 67.60 22 157
Average= 9.66
(KJ/cycle)

Cycle 5 GMT 11/ 5/2023 17:35:59

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 62.7 9 155 15.28 482 1142 1.14 / 34.54 2 15
2 6 4006.4 516 65 14.80 3145 3025 4.17 / 37.57 2 43
3 3 3734.8 697 13 14.92 3050 592 4.76 / 38.16 2 45
4 3 3524.7 878 1 15.04 3060 46 4.80 / 38.21 2 36
5 7 3521.1 1541 80 14.94 2834 3387 8.19 / 41.59 2 49
6 13 2758.0 1703 80 14.94 2362 2823 11.01 / 44.42 2 51
7 13 1986.4 1841 80 14.99 1883 2258 13.27 / 46.67 2 48
8 13 985.0 1991 80 15.12 1241 1501 14.77 / 48.18 2 47
9 13 942.8 1997 80 15.06 1177 1418 16.19 / 49.59 2 49
10 13 738.3 2018 80 15.05 1033 1244 17.44 / 50.84 2 239
11 14 1.2 2090 41 15.16 525 326 17.76 / 51.16 2 114
12 14 1.5 2091 59 15.14 472 422 18.18 / 51.59 28 246
Average= 8.60
(KJ/cycle)

Cycle 4 GMT 10/ 5/2023 6:36: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.3 12 339 15.26 486 2514 2.51 / 28.91 2 16
2 6 1008.5 190 59 15.16 1163 1040 3.55 / 29.95 2 33
3 3 700.9 311 5 15.29 1025 78 3.63 / 30.03 2 35
4 7 504.0 1035 80 15.41 854 1053 4.69 / 31.09 2 33
5 13 471.7 1041 80 15.37 814 1001 5.69 / 32.09 2 34
6 13 49.7 1094 80 15.35 509 625 6.31 / 32.71 2 36
7 14 0.5 1103 52 15.34 460 367 6.68 / 33.08 2 113
8 14 0.6 1104 48 15.32 439 323 7.00 / 33.40 26 246
Average= 6.68
(KJ/cycle)

Cycle 3 GMT 9/ 5/2023 11:59: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.6 12 336 15.25 499 2557 2.56 / 22.21 2 17
2 6 1016.1 179 60 15.16 1180 1073 3.63 / 23.29 2 32
3 3 752.0 300 7 15.28 1066 114 3.74 / 23.40 2 33
4 7 516.6 1024 80 15.41 874 1077 4.82 / 24.48 2 34
5 13 486.0 1030 80 15.36 841 1033 5.86 / 25.51 2 36
6 14 0.5 1097 125 15.35 464 890 6.75 / 26.40 2 104
Average= 6.60
(KJ/cycle)

Cycle 2 GMT 8/ 5/2023 17:31: 0

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 56.1 12 329 15.27 484 2432 2.43 / 15.22 2 17
2 6 1013.1 180 60 15.17 1184 1078 3.51 / 16.30 2 33
3 3 795.5 301 9 15.28 1114 153 3.66 / 16.45 2 34
4 7 587.5 1025 80 15.40 942 1161 4.82 / 17.61 2 34
5 13 553.7 1031 80 15.35 886 1088 5.91 / 18.70 2 37
6 14 0.4 1111 131 15.33 476 956 6.87 / 19.65 2 116
Average= 6.55
(KJ/cycle)

Cycle 1 GMT 7/ 5/2023 22:48: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 60.5 11 279 15.26 424 1805 1.81 / 6.88 2 14
2 6 1028.3 134 59 15.20 1148 1030 2.83 / 7.91 2 26
3 3 1443.8 256 43 15.21 1498 980 3.81 / 8.89 2 37
4 3 1111.8 377 26 15.27 1342 533 4.35 / 9.42 2 40
5 3 741.8 498 7 15.34 1128 121 4.47 / 9.54 2 38
6 7 394.1 981 80 15.43 795 981 5.45 / 10.52 2 32
7 13 362.4 987 80 15.39 758 933 6.38 / 11.46 2 30
8 13 23.1 1030 80 15.37 503 618 7.00 / 12.08 2 40
9 14 0.4 1037 45 15.36 477 330 7.33 / 12.41 2 108
10 14 0.7 1038 55 15.34 453 382 7.71 / 12.79 21 246
Average= 6.39
(KJ/cycle)

Cycle 0 GMT 7/ 5/2023 5:21: 1

Number Code Pressure
(db)
Elapsed
Time (s)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 13 114.1 23931 402 15.49 455 2833 2.83 / 2.83 2 12
2 7 181.3 23933 80 15.41 474 584 3.42 / 3.42 2 11
3 13 167.7 23939 80 15.38 466 573 3.99 / 3.99 2 10
4 13 47.7 23956 80 15.35 399 490 4.48 / 4.48 2 10
5 14 1.1 23967 103 15.33 376 594 5.07 / 5.07 2 132
Average= 5.07