SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 33 | 15.20 | 481 | 241 | 0.24 / 150.86 | 2 | 6 |
2 | 3 | 1017.32 | 1 | 15.31 | 1737 | 27 | 0.27 / 150.89 | 2 | 11 |
3 | 7 | 2006.48 | 38 | 14.99 | 2920 | 1663 | 1.93 / 152.55 | 2 | 13 |
4 | 13 | 1576.48 | 18 | 15.06 | 2411 | 654 | 2.58 / 153.20 | 2 | 15 |
5 | 13 | 1068.28 | 18 | 15.13 | 1776 | 484 | 3.07 / 153.69 | 2 | 18 |
6 | 13 | 456.92 | 18 | 15.24 | 981 | 269 | 3.34 / 153.96 | 2 | 18 |
7 | 13 | 49.56 | 18 | 15.29 | 409 | 113 | 3.45 / 154.07 | 2 | 15 |
8 | 8 | -0.20 | 165 | 15.24 | 328 | 825 | 4.27 / 154.89 | 2 | 20 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 33 | 15.23 | 476 | 239 | 0.24 / 146.70 | 2 | 6 |
2 | 7 | 1919.28 | 38 | 15.00 | 2816 | 1605 | 1.84 / 148.30 | 2 | 15 |
3 | 13 | 1596.72 | 18 | 15.04 | 2448 | 663 | 2.51 / 148.96 | 2 | 17 |
4 | 13 | 1087.96 | 18 | 15.12 | 1799 | 490 | 3.00 / 149.45 | 2 | 17 |
5 | 13 | 408.64 | 18 | 15.24 | 906 | 249 | 3.25 / 149.70 | 2 | 18 |
6 | 13 | 27.20 | 18 | 15.29 | 374 | 103 | 3.35 / 149.81 | 2 | 17 |
7 | 8 | 0.00 | 165 | 15.26 | 323 | 813 | 4.16 / 150.62 | 2 | 24 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 33 | 15.21 | 470 | 236 | 0.24 / 143.04 | 2 | 7 |
2 | 7 | 1507.00 | 39 | 15.14 | 2308 | 1363 | 1.60 / 144.40 | 2 | 16 |
3 | 13 | 1461.00 | 18 | 15.11 | 2259 | 614 | 2.21 / 145.02 | 2 | 16 |
4 | 13 | 910.92 | 18 | 15.20 | 1580 | 432 | 2.65 / 145.45 | 2 | 18 |
5 | 13 | 257.64 | 18 | 15.30 | 695 | 191 | 2.84 / 145.64 | 2 | 18 |
6 | 8 | 0.28 | 165 | 15.29 | 323 | 815 | 3.65 / 146.46 | 2 | 24 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 33 | 15.24 | 479 | 241 | 0.24 / 139.26 | 2 | 7 |
2 | 7 | 1670.04 | 38 | 15.10 | 2515 | 1443 | 1.68 / 140.71 | 2 | 16 |
3 | 13 | 1471.28 | 18 | 15.09 | 2273 | 617 | 2.30 / 141.32 | 2 | 17 |
4 | 13 | 921.40 | 18 | 15.18 | 1585 | 433 | 2.73 / 141.76 | 2 | 18 |
5 | 13 | 331.44 | 18 | 15.27 | 802 | 220 | 2.95 / 141.98 | 2 | 18 |
6 | 8 | -0.16 | 165 | 15.28 | 329 | 829 | 3.78 / 142.81 | 2 | 20 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 33 | 15.27 | 467 | 235 | 0.24 / 135.68 | 2 | 7 |
2 | 7 | 1488.84 | 38 | 15.15 | 2273 | 1309 | 1.54 / 136.99 | 2 | 17 |
3 | 13 | 1445.96 | 18 | 15.15 | 2232 | 609 | 2.15 / 137.59 | 2 | 14 |
4 | 13 | 819.84 | 18 | 15.22 | 1449 | 397 | 2.55 / 137.99 | 2 | 17 |
5 | 13 | 311.80 | 18 | 15.31 | 769 | 212 | 2.76 / 138.20 | 2 | 18 |
6 | 8 | 0.00 | 165 | 15.29 | 324 | 817 | 3.58 / 139.02 | 2 | 26 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 33 | 15.22 | 475 | 239 | 0.24 / 132.30 | 2 | 6 |
2 | 3 | 969.40 | -1 | 15.62 | 0 | 0 | 0.00 / 132.30 | 2 | 6 |
3 | 7 | 1218.64 | 38 | 15.27 | 1936 | 1123 | 1.36 / 133.42 | 2 | 15 |
4 | 13 | 1185.28 | 18 | 15.24 | 1908 | 523 | 1.89 / 133.94 | 2 | 15 |
5 | 13 | 1026.64 | 18 | 15.24 | 1722 | 472 | 2.36 / 134.42 | 2 | 18 |
6 | 13 | 303.76 | 18 | 15.34 | 766 | 212 | 2.57 / 134.63 | 2 | 18 |
7 | 8 | -0.16 | 165 | 15.33 | 322 | 814 | 3.38 / 135.44 | 2 | 20 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 33 | 15.21 | 472 | 237 | 0.24 / 128.43 | 2 | 6 |
2 | 7 | 1697.72 | 38 | 15.08 | 2549 | 1461 | 1.70 / 129.89 | 2 | 15 |
3 | 13 | 1449.56 | 18 | 15.10 | 2259 | 614 | 2.31 / 130.50 | 2 | 17 |
4 | 13 | 925.40 | 18 | 15.16 | 1597 | 436 | 2.75 / 130.94 | 2 | 19 |
5 | 13 | 269.72 | 18 | 15.28 | 717 | 197 | 2.94 / 131.13 | 2 | 18 |
6 | 13 | 19.28 | 18 | 15.32 | 368 | 101 | 3.05 / 131.23 | 2 | 20 |
7 | 8 | -0.16 | 165 | 15.27 | 327 | 824 | 3.87 / 132.06 | 2 | 28 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 33 | 15.29 | 491 | 248 | 0.25 / 124.29 | 2 | 6 |
2 | 7 | 1906.84 | 39 | 14.99 | 2817 | 1647 | 1.89 / 125.93 | 2 | 16 |
3 | 13 | 1519.52 | 18 | 15.04 | 2344 | 635 | 2.53 / 126.57 | 2 | 17 |
4 | 13 | 1007.56 | 18 | 15.12 | 1702 | 463 | 2.99 / 127.03 | 2 | 20 |
5 | 13 | 305.52 | 18 | 15.27 | 778 | 214 | 3.21 / 127.25 | 2 | 18 |
6 | 13 | 61.76 | 18 | 15.30 | 432 | 119 | 3.33 / 127.37 | 2 | 18 |
7 | 8 | -0.12 | 165 | 15.26 | 327 | 823 | 4.15 / 128.19 | 2 | 22 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 32 | 15.27 | 485 | 237 | 0.24 / 121.13 | 2 | 6 |
2 | 7 | 1078.96 | 38 | 15.32 | 1776 | 1034 | 1.27 / 122.17 | 2 | 14 |
3 | 13 | 1055.48 | 18 | 15.30 | 1753 | 483 | 1.75 / 122.65 | 2 | 15 |
4 | 13 | 811.32 | 18 | 15.31 | 1441 | 397 | 2.15 / 123.05 | 2 | 17 |
5 | 13 | 144.84 | 18 | 15.40 | 545 | 151 | 2.30 / 123.20 | 2 | 17 |
6 | 8 | 0.32 | 165 | 15.36 | 332 | 841 | 3.14 / 124.04 | 2 | 22 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 32 | 15.26 | 485 | 237 | 0.24 / 117.59 | 2 | 6 |
2 | 7 | 1290.08 | 38 | 15.25 | 2038 | 1181 | 1.42 / 118.77 | 2 | 14 |
3 | 13 | 1260.64 | 18 | 15.22 | 2015 | 552 | 1.97 / 119.32 | 2 | 15 |
4 | 13 | 798.00 | 18 | 15.28 | 1438 | 396 | 2.37 / 119.71 | 2 | 18 |
5 | 13 | 245.92 | 18 | 15.36 | 694 | 192 | 2.56 / 119.91 | 2 | 17 |
6 | 8 | -0.08 | 165 | 15.34 | 331 | 838 | 3.40 / 120.74 | 2 | 25 |
7 | 14 | -0.08 | 30 | 15.31 | 332 | 152 | 3.55 / 120.90 | 3 | 21 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 32 | 15.24 | 489 | 238 | 0.24 / 113.79 | 2 | 7 |
2 | 7 | 1612.24 | 38 | 15.15 | 2443 | 1406 | 1.64 / 115.20 | 2 | 16 |
3 | 13 | 1362.92 | 18 | 15.18 | 2158 | 590 | 2.23 / 115.79 | 2 | 17 |
4 | 13 | 991.28 | 18 | 15.22 | 1683 | 461 | 2.70 / 116.25 | 2 | 19 |
5 | 13 | 435.60 | 18 | 15.29 | 952 | 262 | 2.96 / 116.51 | 2 | 19 |
6 | 8 | 0.20 | 165 | 15.31 | 332 | 839 | 3.80 / 117.35 | 2 | 28 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 32 | 15.24 | 485 | 237 | 0.24 / 109.97 | 2 | 6 |
2 | 7 | 1614.88 | 39 | 15.14 | 2451 | 1447 | 1.68 / 111.41 | 2 | 15 |
3 | 13 | 1521.48 | 18 | 15.13 | 2359 | 642 | 2.33 / 112.06 | 2 | 16 |
4 | 13 | 904.96 | 18 | 15.21 | 1573 | 431 | 2.76 / 112.49 | 2 | 19 |
5 | 13 | 318.76 | 18 | 15.32 | 791 | 218 | 2.97 / 112.70 | 2 | 18 |
6 | 8 | 0.28 | 165 | 15.31 | 336 | 849 | 3.82 / 113.55 | 2 | 22 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 32 | 15.26 | 483 | 236 | 0.24 / 106.08 | 2 | 7 |
2 | 7 | 1768.20 | 38 | 15.08 | 2650 | 1519 | 1.75 / 107.60 | 2 | 16 |
3 | 13 | 1466.96 | 18 | 15.11 | 2285 | 621 | 2.38 / 108.22 | 2 | 16 |
4 | 13 | 1019.36 | 18 | 15.16 | 1724 | 470 | 2.85 / 108.69 | 2 | 18 |
5 | 13 | 243.84 | 18 | 15.34 | 688 | 190 | 3.04 / 108.88 | 2 | 18 |
6 | 8 | 0.32 | 165 | 15.34 | 334 | 845 | 3.88 / 109.73 | 2 | 19 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 32 | 15.24 | 485 | 237 | 0.24 / 102.19 | 2 | 6 |
2 | 7 | 1725.76 | 39 | 15.10 | 2587 | 1523 | 1.76 / 103.71 | 2 | 14 |
3 | 13 | 1520.64 | 18 | 15.13 | 2343 | 638 | 2.40 / 104.35 | 2 | 16 |
4 | 13 | 907.40 | 18 | 15.21 | 1578 | 432 | 2.83 / 104.78 | 2 | 18 |
5 | 13 | 322.32 | 18 | 15.32 | 804 | 222 | 3.05 / 105.01 | 2 | 18 |
6 | 8 | 0.52 | 165 | 15.32 | 333 | 842 | 3.89 / 105.85 | 2 | 21 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 32 | 15.25 | 487 | 238 | 0.24 / 98.24 | 2 | 7 |
2 | 3 | 1022.84 | 1 | 15.33 | 1774 | 27 | 0.26 / 98.27 | 2 | 12 |
3 | 7 | 1853.48 | 38 | 15.05 | 2745 | 1570 | 1.83 / 99.83 | 2 | 15 |
4 | 13 | 1448.12 | 18 | 15.09 | 2265 | 615 | 2.45 / 100.45 | 2 | 17 |
5 | 13 | 1019.44 | 18 | 15.16 | 1717 | 469 | 2.92 / 100.92 | 2 | 18 |
6 | 13 | 271.00 | 18 | 15.31 | 724 | 200 | 3.12 / 101.12 | 2 | 18 |
7 | 8 | -0.16 | 165 | 15.30 | 331 | 836 | 3.95 / 101.95 | 2 | 21 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 32 | 15.25 | 493 | 241 | 0.24 / 94.53 | 2 | 6 |
2 | 7 | 1567.84 | 38 | 15.17 | 2392 | 1379 | 1.62 / 95.90 | 2 | 15 |
3 | 13 | 1429.16 | 18 | 15.17 | 2235 | 610 | 2.23 / 96.51 | 2 | 16 |
4 | 13 | 989.64 | 18 | 15.21 | 1675 | 459 | 2.69 / 96.97 | 2 | 18 |
5 | 13 | 219.40 | 18 | 15.34 | 652 | 180 | 2.87 / 97.15 | 2 | 17 |
6 | 8 | -0.28 | 165 | 15.32 | 335 | 847 | 3.72 / 98.00 | 2 | 20 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 32 | 15.24 | 487 | 238 | 0.24 / 90.53 | 2 | 8 |
2 | 7 | 1858.68 | 38 | 15.04 | 2750 | 1572 | 1.81 / 92.11 | 2 | 14 |
3 | 13 | 1542.48 | 18 | 15.08 | 2389 | 648 | 2.46 / 92.75 | 2 | 17 |
4 | 13 | 1031.08 | 18 | 15.14 | 1740 | 474 | 2.93 / 93.23 | 2 | 19 |
5 | 13 | 267.72 | 18 | 15.31 | 725 | 200 | 3.13 / 93.43 | 2 | 18 |
6 | 8 | -0.12 | 165 | 15.31 | 339 | 856 | 3.99 / 94.29 | 2 | 23 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 32 | 15.26 | 502 | 245 | 0.25 / 86.56 | 2 | 7 |
2 | 7 | 1874.48 | 38 | 15.04 | 2775 | 1586 | 1.83 / 88.15 | 2 | 15 |
3 | 13 | 1554.20 | 18 | 15.08 | 2399 | 651 | 2.48 / 88.80 | 2 | 17 |
4 | 13 | 905.04 | 18 | 15.20 | 1576 | 431 | 2.91 / 89.23 | 2 | 19 |
5 | 13 | 271.08 | 18 | 15.30 | 732 | 202 | 3.12 / 89.43 | 2 | 17 |
6 | 8 | 0.12 | 165 | 15.31 | 343 | 866 | 3.98 / 90.30 | 2 | 25 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 32 | 15.27 | 491 | 240 | 0.24 / 82.40 | 2 | 7 |
2 | 10 | 1013.08 | 2 | 15.33 | 1767 | 54 | 0.29 / 82.45 | 2 | 11 |
3 | 3 | 976.00 | -1 | 15.61 | 0 | 0 | 0.05 / 82.45 | 2 | 11 |
4 | 7 | 2004.32 | 38 | 15.03 | 2927 | 1672 | 1.97 / 84.13 | 2 | 14 |
5 | 13 | 1587.40 | 18 | 15.09 | 2434 | 661 | 2.63 / 84.79 | 2 | 16 |
6 | 13 | 1025.20 | 18 | 15.16 | 1734 | 473 | 3.10 / 85.26 | 2 | 18 |
7 | 13 | 309.28 | 18 | 15.30 | 776 | 214 | 3.31 / 85.47 | 2 | 18 |
8 | 8 | 0.04 | 165 | 15.31 | 333 | 841 | 4.16 / 86.32 | 2 | 21 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 31 | 15.26 | 495 | 234 | 0.23 / 78.29 | 2 | 8 |
2 | 7 | 2015.80 | 39 | 15.03 | 2945 | 1726 | 1.96 / 80.02 | 2 | 13 |
3 | 13 | 1490.04 | 18 | 15.11 | 2316 | 630 | 2.59 / 80.65 | 2 | 16 |
4 | 13 | 968.08 | 18 | 15.19 | 1652 | 452 | 3.04 / 81.10 | 2 | 18 |
5 | 13 | 276.64 | 18 | 15.31 | 736 | 203 | 3.24 / 81.30 | 2 | 18 |
6 | 8 | 0.00 | 165 | 15.31 | 340 | 859 | 4.10 / 82.16 | 2 | 25 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 31 | 15.26 | 493 | 233 | 0.23 / 74.17 | 2 | 7 |
2 | 7 | 2011.76 | 38 | 15.03 | 2942 | 1680 | 1.91 / 75.85 | 2 | 12 |
3 | 13 | 1626.16 | 18 | 15.08 | 2481 | 673 | 2.59 / 76.52 | 2 | 15 |
4 | 13 | 1013.76 | 18 | 15.17 | 1711 | 467 | 3.05 / 76.99 | 2 | 19 |
5 | 13 | 311.44 | 18 | 15.31 | 792 | 218 | 3.27 / 77.21 | 2 | 18 |
6 | 8 | 0.08 | 165 | 15.32 | 336 | 849 | 4.12 / 78.06 | 2 | 23 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 31 | 15.25 | 493 | 233 | 0.23 / 70.01 | 2 | 7 |
2 | 7 | 2002.92 | 38 | 15.03 | 2929 | 1673 | 1.91 / 71.69 | 2 | 12 |
3 | 13 | 1570.44 | 18 | 15.11 | 2417 | 657 | 2.56 / 72.34 | 2 | 16 |
4 | 13 | 1109.24 | 18 | 15.16 | 1840 | 502 | 3.07 / 72.85 | 2 | 18 |
5 | 13 | 370.28 | 18 | 15.29 | 867 | 239 | 3.30 / 73.09 | 2 | 19 |
6 | 8 | 0.12 | 165 | 15.32 | 336 | 849 | 4.15 / 73.93 | 2 | 18 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 31 | 15.25 | 492 | 233 | 0.23 / 65.84 | 2 | 9 |
2 | 7 | 2010.28 | 38 | 15.03 | 2937 | 1677 | 1.91 / 67.52 | 2 | 13 |
3 | 13 | 1552.60 | 18 | 15.09 | 2391 | 649 | 2.56 / 68.17 | 2 | 15 |
4 | 13 | 1104.40 | 18 | 15.15 | 1832 | 500 | 3.06 / 68.67 | 2 | 18 |
5 | 13 | 410.84 | 18 | 15.29 | 924 | 254 | 3.31 / 68.92 | 2 | 19 |
6 | 8 | 0.28 | 165 | 15.30 | 340 | 858 | 4.17 / 69.78 | 2 | 20 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 31 | 15.27 | 493 | 233 | 0.23 / 61.74 | 2 | 7 |
2 | 7 | 2003.48 | 38 | 15.05 | 2932 | 1677 | 1.91 / 63.42 | 2 | 13 |
3 | 13 | 1498.40 | 18 | 15.10 | 2327 | 632 | 2.54 / 64.05 | 2 | 16 |
4 | 13 | 997.32 | 18 | 15.18 | 1694 | 463 | 3.01 / 64.51 | 2 | 18 |
5 | 13 | 374.04 | 18 | 15.30 | 874 | 241 | 3.25 / 64.76 | 2 | 19 |
6 | 8 | 0.40 | 165 | 15.32 | 338 | 854 | 4.10 / 65.61 | 2 | 24 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 31 | 15.27 | 491 | 232 | 0.23 / 57.65 | 2 | 6 |
2 | 7 | 2006.92 | 38 | 15.05 | 2928 | 1675 | 1.91 / 59.33 | 2 | 12 |
3 | 13 | 1472.80 | 18 | 15.13 | 2297 | 626 | 2.53 / 59.95 | 2 | 16 |
4 | 13 | 915.76 | 18 | 15.22 | 1588 | 435 | 2.97 / 60.39 | 2 | 18 |
5 | 13 | 415.28 | 18 | 15.31 | 933 | 257 | 3.22 / 60.65 | 2 | 19 |
6 | 8 | 0.08 | 165 | 15.33 | 341 | 863 | 4.09 / 61.51 | 2 | 28 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 31 | 15.28 | 497 | 235 | 0.24 / 53.53 | 2 | 7 |
2 | 7 | 2005.56 | 38 | 15.05 | 2936 | 1679 | 1.91 / 55.21 | 2 | 11 |
3 | 13 | 1507.28 | 18 | 15.13 | 2331 | 635 | 2.55 / 55.85 | 2 | 14 |
4 | 13 | 960.12 | 18 | 15.21 | 1650 | 452 | 3.00 / 56.30 | 2 | 17 |
5 | 13 | 400.28 | 18 | 15.31 | 915 | 252 | 3.25 / 56.55 | 2 | 17 |
6 | 8 | 0.00 | 165 | 15.33 | 344 | 870 | 4.12 / 57.42 | 2 | 19 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 31 | 15.27 | 489 | 231 | 0.23 / 49.42 | 2 | 6 |
2 | 7 | 2008.88 | 38 | 15.06 | 2942 | 1684 | 1.92 / 51.11 | 2 | 11 |
3 | 13 | 1467.64 | 18 | 15.13 | 2291 | 624 | 2.54 / 51.73 | 2 | 15 |
4 | 13 | 1028.44 | 18 | 15.18 | 1739 | 475 | 3.01 / 52.20 | 2 | 17 |
5 | 13 | 345.12 | 18 | 15.30 | 833 | 229 | 3.24 / 52.43 | 2 | 17 |
6 | 8 | -0.28 | 165 | 15.32 | 342 | 865 | 4.11 / 53.30 | 2 | 22 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 31 | 15.28 | 480 | 227 | 0.23 / 45.30 | 2 | 6 |
2 | 7 | 2002.96 | 39 | 15.06 | 2920 | 1715 | 1.94 / 47.01 | 2 | 11 |
3 | 13 | 1539.04 | 18 | 15.12 | 2365 | 644 | 2.59 / 47.66 | 2 | 15 |
4 | 13 | 993.80 | 18 | 15.18 | 1692 | 462 | 3.05 / 48.12 | 2 | 17 |
5 | 13 | 334.64 | 18 | 15.31 | 819 | 226 | 3.27 / 48.34 | 2 | 17 |
6 | 8 | 0.28 | 165 | 15.33 | 335 | 847 | 4.12 / 49.19 | 2 | 21 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 31 | 15.28 | 485 | 230 | 0.23 / 41.30 | 2 | 6 |
2 | 7 | 2004.92 | 38 | 15.07 | 2926 | 1676 | 1.91 / 42.97 | 2 | 11 |
3 | 13 | 1461.28 | 18 | 15.14 | 2278 | 621 | 2.53 / 43.59 | 2 | 15 |
4 | 13 | 876.96 | 18 | 15.22 | 1541 | 422 | 2.95 / 44.01 | 2 | 17 |
5 | 13 | 293.36 | 18 | 15.34 | 760 | 210 | 3.16 / 44.22 | 2 | 17 |
6 | 8 | -0.16 | 165 | 15.33 | 334 | 845 | 4.00 / 45.07 | 2 | 24 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 31 | 15.27 | 499 | 236 | 0.24 / 36.68 | 2 | 6 |
2 | 10 | 1011.32 | 2 | 15.33 | 1769 | 54 | 0.29 / 36.74 | 2 | 10 |
3 | 7 | 2008.76 | 74 | 14.95 | 2922 | 3233 | 3.52 / 39.97 | 2 | 13 |
4 | 13 | 409.60 | 18 | 15.31 | 917 | 253 | 3.78 / 40.22 | 2 | 17 |
5 | 8 | 0.00 | 165 | 15.33 | 334 | 845 | 4.62 / 41.07 | 2 | 23 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 30 | 15.28 | 488 | 224 | 0.22 / 32.00 | 2 | 6 |
2 | 10 | 1003.04 | 2 | 15.32 | 1745 | 53 | 0.28 / 32.05 | 2 | 9 |
3 | 3 | 967.72 | -1 | 15.65 | 0 | 0 | 0.05 / 32.05 | 2 | 9 |
4 | 7 | 2011.20 | 74 | 14.95 | 2921 | 3232 | 3.51 / 35.28 | 2 | 13 |
5 | 13 | 504.08 | 18 | 15.29 | 1056 | 291 | 3.80 / 35.58 | 2 | 18 |
6 | 8 | 0.28 | 165 | 15.33 | 344 | 870 | 4.67 / 36.45 | 2 | 23 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 30 | 15.27 | 497 | 228 | 0.23 / 27.27 | 2 | 6 |
2 | 7 | 2005.16 | 74 | 14.94 | 2911 | 3218 | 3.45 / 30.49 | 2 | 12 |
3 | 13 | 572.60 | 18 | 15.27 | 1131 | 311 | 3.76 / 30.80 | 2 | 17 |
4 | 13 | 42.16 | 18 | 15.35 | 407 | 112 | 3.87 / 30.92 | 2 | 15 |
5 | 8 | 0.16 | 165 | 15.32 | 340 | 859 | 4.73 / 31.78 | 2 | 20 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 30 | 15.29 | 497 | 228 | 0.23 / 23.12 | 2 | 5 |
2 | 7 | 1706.68 | 75 | 15.04 | 2548 | 2874 | 3.10 / 25.99 | 2 | 13 |
3 | 13 | 239.40 | 18 | 15.33 | 685 | 189 | 3.29 / 26.18 | 2 | 15 |
4 | 8 | 0.36 | 165 | 15.33 | 343 | 868 | 4.16 / 27.05 | 2 | 20 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 30 | 15.30 | 493 | 226 | 0.23 / 19.46 | 2 | 6 |
2 | 7 | 1399.00 | 74 | 15.15 | 2168 | 2431 | 2.66 / 21.89 | 2 | 13 |
3 | 13 | 65.68 | 18 | 15.39 | 447 | 124 | 2.78 / 22.01 | 2 | 14 |
4 | 8 | 0.24 | 165 | 15.35 | 345 | 874 | 3.65 / 22.89 | 2 | 21 |
Average= | 3.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 29 | 15.30 | 499 | 221 | 0.22 / 15.91 | 2 | 5 |
2 | 7 | 1392.12 | 75 | 15.15 | 2152 | 2445 | 2.67 / 18.36 | 2 | 14 |
3 | 8 | 0.12 | 165 | 15.36 | 345 | 874 | 3.54 / 19.23 | 2 | 23 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 25 | 15.27 | 505 | 193 | 0.19 / 12.34 | 2 | 5 |
2 | 10 | 1057.60 | 3 | 15.29 | 1820 | 83 | 0.28 / 12.43 | 2 | 8 |
3 | 3 | 1095.48 | 3 | 15.34 | 1885 | 87 | 0.36 / 12.51 | 2 | 12 |
4 | 3 | 1017.64 | 1 | 15.39 | 1779 | 27 | 0.39 / 12.54 | 2 | 12 |
5 | 7 | 1290.28 | 74 | 15.19 | 2022 | 2273 | 2.66 / 14.81 | 2 | 14 |
6 | 8 | 0.20 | 165 | 15.36 | 347 | 879 | 3.54 / 15.69 | 2 | 22 |
Average= | 3.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 39 | 15.30 | 503 | 300 | 0.30 / 8.50 | 2 | 5 |
2 | 3 | 658.24 | -6 | 15.64 | 0 | 0 | 0.00 / 8.50 | 2 | 5 |
3 | 3 | 804.56 | -4 | 15.69 | 0 | 0 | 0.00 / 8.50 | 2 | 5 |
4 | 7 | 1518.36 | 74 | 15.11 | 2311 | 2584 | 2.88 / 11.08 | 2 | 12 |
5 | 13 | 251.92 | 18 | 15.33 | 705 | 195 | 3.08 / 11.28 | 2 | 15 |
6 | 8 | 0.08 | 165 | 15.32 | 345 | 872 | 3.95 / 12.15 | 2 | 23 |
Average= | 3.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 33 | 15.29 | 498 | 251 | 0.25 / 5.13 | 2 | 6 |
2 | 10 | 1067.64 | 4 | 15.29 | 1807 | 111 | 0.36 / 5.24 | 2 | 8 |
3 | 10 | 1099.08 | 2 | 15.30 | 1870 | 57 | 0.42 / 5.29 | 2 | 8 |
4 | 3 | 1080.40 | 2 | 15.33 | 1861 | 57 | 0.48 / 5.35 | 2 | 11 |
5 | 7 | 1059.28 | 74 | 15.26 | 1739 | 1964 | 2.44 / 7.31 | 2 | 15 |
6 | 8 | 0.08 | 165 | 15.38 | 349 | 886 | 3.33 / 8.20 | 2 | 25 |
Average= | 2.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 28 | 15.45 | 468 | 202 | 0.20 / 2.10 | 2 | 3 |
2 | 10 | 1015.64 | 2 | 15.36 | 1745 | 54 | 0.26 / 2.15 | 2 | 7 |
3 | 7 | 999.68 | 74 | 15.24 | 1650 | 1861 | 2.12 / 4.01 | 2 | 14 |
4 | 8 | -0.12 | 165 | 15.35 | 341 | 864 | 2.98 / 4.87 | 2 | 22 |
Average= | 2.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 27 | 15.62 | 473 | 199 | 0.20 / 0.20 | 2 | 4 |
2 | 7 | 127.48 | 75 | 15.59 | 485 | 567 | 0.77 / 0.77 | 2 | 6 |
3 | 8 | 0.08 | 240 | 15.55 | 302 | 1127 | 1.89 / 1.89 | 2 | 18 |
Average= | 1.89 (KJ/cycle) |