SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 30 | 15.21 | 447 | 204 | 0.20 / 161.81 | 2 | 3 |
2 | 7 | 2010.00 | 38 | 14.85 | 2982 | 1683 | 1.89 / 163.49 | 2 | 14 |
3 | 13 | 1462.00 | 18 | 14.95 | 2308 | 621 | 2.51 / 164.11 | 2 | 19 |
4 | 13 | 1031.08 | 18 | 15.02 | 1748 | 473 | 2.98 / 164.58 | 2 | 19 |
5 | 13 | 517.20 | 18 | 15.15 | 1051 | 287 | 3.27 / 164.87 | 2 | 19 |
6 | 13 | 108.00 | 18 | 15.25 | 470 | 129 | 3.40 / 165.00 | 2 | 15 |
7 | 8 | 0.12 | 165 | 15.24 | 313 | 787 | 4.18 / 165.79 | 2 | 15 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 30 | 15.20 | 464 | 212 | 0.21 / 157.70 | 2 | 4 |
2 | 7 | 2010.96 | 38 | 14.85 | 2984 | 1684 | 1.90 / 159.39 | 2 | 15 |
3 | 13 | 1418.68 | 18 | 14.95 | 2280 | 614 | 2.51 / 160.00 | 2 | 17 |
4 | 13 | 979.44 | 18 | 15.03 | 1708 | 462 | 2.97 / 160.46 | 2 | 19 |
5 | 13 | 375.68 | 18 | 15.20 | 865 | 237 | 3.21 / 160.70 | 2 | 19 |
6 | 13 | 101.56 | 18 | 15.26 | 456 | 125 | 3.33 / 160.82 | 2 | 14 |
7 | 8 | 0.08 | 165 | 15.25 | 310 | 780 | 4.11 / 161.60 | 2 | 18 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 30 | 15.20 | 458 | 209 | 0.21 / 153.55 | 2 | 4 |
2 | 7 | 2003.92 | 38 | 14.87 | 2992 | 1691 | 1.90 / 155.24 | 2 | 14 |
3 | 13 | 1504.36 | 18 | 14.96 | 2378 | 640 | 2.54 / 155.88 | 2 | 21 |
4 | 13 | 880.20 | 18 | 15.07 | 1575 | 427 | 2.97 / 156.31 | 2 | 20 |
5 | 13 | 405.24 | 18 | 15.20 | 916 | 251 | 3.22 / 156.56 | 2 | 18 |
6 | 13 | 124.08 | 18 | 15.26 | 498 | 137 | 3.35 / 156.70 | 2 | 15 |
7 | 8 | 0.12 | 165 | 15.25 | 316 | 795 | 4.15 / 157.49 | 2 | 18 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 30 | 15.22 | 459 | 210 | 0.21 / 149.37 | 2 | 3 |
2 | 7 | 2007.08 | 38 | 14.87 | 2978 | 1683 | 1.89 / 151.05 | 2 | 13 |
3 | 13 | 1513.00 | 18 | 14.96 | 2365 | 637 | 2.53 / 151.69 | 2 | 18 |
4 | 13 | 1019.68 | 18 | 15.03 | 1757 | 475 | 3.00 / 152.17 | 2 | 20 |
5 | 13 | 403.76 | 18 | 15.19 | 894 | 244 | 3.25 / 152.41 | 2 | 19 |
6 | 13 | 118.72 | 18 | 15.27 | 486 | 134 | 3.38 / 152.54 | 2 | 16 |
7 | 8 | -0.04 | 165 | 15.25 | 317 | 798 | 4.18 / 153.34 | 2 | 15 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 30 | 15.22 | 454 | 207 | 0.21 / 145.28 | 2 | 3 |
2 | 7 | 2010.24 | 39 | 14.86 | 2980 | 1727 | 1.93 / 147.01 | 2 | 13 |
3 | 13 | 1473.56 | 18 | 14.96 | 2312 | 623 | 2.56 / 147.63 | 2 | 17 |
4 | 13 | 819.40 | 18 | 15.09 | 1468 | 399 | 2.96 / 148.03 | 2 | 19 |
5 | 13 | 295.00 | 18 | 15.23 | 723 | 198 | 3.15 / 148.23 | 2 | 18 |
6 | 13 | 85.84 | 18 | 15.28 | 409 | 112 | 3.27 / 148.34 | 2 | 14 |
7 | 13 | 22.12 | 18 | 15.29 | 315 | 87 | 3.35 / 148.43 | 2 | 15 |
8 | 8 | -0.20 | 165 | 15.25 | 292 | 735 | 4.09 / 149.16 | 2 | 17 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 30 | 15.23 | 445 | 203 | 0.20 / 141.01 | 2 | 4 |
2 | 7 | 2004.56 | 38 | 14.86 | 2996 | 1692 | 1.90 / 142.70 | 2 | 21 |
3 | 13 | 1544.64 | 18 | 14.94 | 2442 | 657 | 2.55 / 143.35 | 2 | 23 |
4 | 13 | 933.32 | 18 | 15.06 | 1648 | 447 | 3.00 / 143.80 | 2 | 18 |
5 | 13 | 422.96 | 18 | 15.19 | 941 | 257 | 3.26 / 144.06 | 2 | 21 |
6 | 13 | 92.48 | 18 | 15.29 | 455 | 125 | 3.38 / 144.18 | 2 | 15 |
7 | 13 | 23.48 | 18 | 15.28 | 353 | 97 | 3.48 / 144.28 | 2 | 17 |
8 | 8 | -0.20 | 165 | 15.25 | 315 | 793 | 4.27 / 145.07 | 2 | 18 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 30 | 15.22 | 462 | 211 | 0.21 / 136.79 | 2 | 4 |
2 | 7 | 2009.12 | 39 | 14.87 | 2976 | 1726 | 1.94 / 138.51 | 2 | 16 |
3 | 13 | 1445.64 | 18 | 14.97 | 2287 | 616 | 2.55 / 139.13 | 2 | 19 |
4 | 13 | 1035.60 | 18 | 15.04 | 1779 | 482 | 3.03 / 139.61 | 2 | 19 |
5 | 13 | 421.88 | 18 | 15.19 | 944 | 258 | 3.29 / 139.87 | 2 | 20 |
6 | 13 | 130.36 | 18 | 15.27 | 504 | 139 | 3.43 / 140.01 | 2 | 16 |
7 | 8 | 0.16 | 165 | 15.26 | 316 | 796 | 4.23 / 140.80 | 2 | 15 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 30 | 15.21 | 446 | 204 | 0.20 / 132.72 | 2 | 4 |
2 | 7 | 2008.36 | 38 | 14.87 | 2965 | 1675 | 1.88 / 134.39 | 2 | 14 |
3 | 13 | 1360.92 | 18 | 15.00 | 2169 | 586 | 2.46 / 134.98 | 2 | 17 |
4 | 13 | 896.88 | 18 | 15.06 | 1567 | 425 | 2.89 / 135.41 | 2 | 20 |
5 | 13 | 351.76 | 18 | 15.21 | 829 | 227 | 3.12 / 135.63 | 2 | 19 |
6 | 13 | 128.20 | 18 | 15.26 | 503 | 138 | 3.25 / 135.77 | 2 | 15 |
7 | 8 | 0.20 | 165 | 15.25 | 320 | 805 | 4.06 / 136.58 | 2 | 20 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 30 | 15.23 | 463 | 212 | 0.21 / 128.55 | 2 | 4 |
2 | 7 | 2009.16 | 38 | 14.88 | 2978 | 1684 | 1.90 / 130.23 | 2 | 15 |
3 | 13 | 1558.96 | 18 | 14.96 | 2422 | 652 | 2.55 / 130.88 | 2 | 15 |
4 | 13 | 984.12 | 18 | 15.06 | 1686 | 457 | 3.00 / 131.34 | 2 | 21 |
5 | 13 | 408.68 | 18 | 15.21 | 897 | 246 | 3.25 / 131.59 | 2 | 19 |
6 | 13 | 125.68 | 18 | 15.27 | 464 | 128 | 3.38 / 131.71 | 2 | 16 |
7 | 13 | 16.00 | 18 | 15.31 | 303 | 84 | 3.46 / 131.80 | 2 | 15 |
8 | 8 | -0.12 | 165 | 15.26 | 285 | 718 | 4.18 / 132.52 | 2 | 17 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 30 | 15.22 | 461 | 210 | 0.21 / 124.57 | 2 | 4 |
2 | 7 | 2012.24 | 38 | 14.89 | 2988 | 1691 | 1.90 / 126.26 | 2 | 13 |
3 | 13 | 1382.04 | 18 | 14.99 | 2200 | 594 | 2.49 / 126.86 | 2 | 20 |
4 | 13 | 871.24 | 18 | 15.09 | 1542 | 419 | 2.91 / 127.28 | 2 | 19 |
5 | 13 | 347.16 | 18 | 15.22 | 802 | 220 | 3.13 / 127.50 | 2 | 18 |
6 | 13 | 94.64 | 18 | 15.29 | 418 | 115 | 3.25 / 127.61 | 2 | 14 |
7 | 8 | 0.08 | 165 | 15.27 | 288 | 726 | 3.97 / 128.34 | 2 | 22 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 30 | 15.23 | 443 | 202 | 0.20 / 120.53 | 2 | 4 |
2 | 7 | 2007.28 | 38 | 14.88 | 2969 | 1679 | 1.88 / 122.21 | 2 | 14 |
3 | 13 | 1410.60 | 18 | 14.99 | 2235 | 603 | 2.48 / 122.82 | 2 | 16 |
4 | 13 | 882.32 | 18 | 15.08 | 1548 | 420 | 2.90 / 123.24 | 2 | 19 |
5 | 13 | 394.00 | 18 | 15.21 | 872 | 239 | 3.14 / 123.47 | 2 | 19 |
6 | 13 | 119.48 | 18 | 15.27 | 453 | 125 | 3.27 / 123.60 | 2 | 15 |
7 | 8 | 0.08 | 165 | 15.27 | 303 | 763 | 4.03 / 124.36 | 2 | 16 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 30 | 15.24 | 435 | 199 | 0.20 / 116.54 | 2 | 4 |
2 | 7 | 2010.72 | 38 | 14.89 | 2978 | 1685 | 1.88 / 118.23 | 2 | 14 |
3 | 13 | 1464.04 | 18 | 14.98 | 2302 | 621 | 2.50 / 118.85 | 2 | 17 |
4 | 13 | 880.12 | 18 | 15.08 | 1545 | 419 | 2.92 / 119.27 | 2 | 21 |
5 | 13 | 433.36 | 18 | 15.21 | 925 | 253 | 3.18 / 119.52 | 2 | 19 |
6 | 13 | 149.84 | 18 | 15.28 | 497 | 137 | 3.31 / 119.66 | 2 | 15 |
7 | 8 | -0.08 | 165 | 15.28 | 268 | 676 | 3.99 / 120.33 | 2 | 15 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 30 | 15.24 | 463 | 212 | 0.21 / 112.39 | 2 | 3 |
2 | 7 | 2010.68 | 39 | 14.88 | 2975 | 1726 | 1.94 / 114.12 | 2 | 16 |
3 | 13 | 1561.64 | 18 | 14.96 | 2454 | 661 | 2.60 / 114.78 | 2 | 15 |
4 | 13 | 950.56 | 18 | 15.07 | 1670 | 453 | 3.05 / 115.23 | 2 | 21 |
5 | 13 | 310.96 | 18 | 15.24 | 767 | 210 | 3.26 / 115.44 | 2 | 17 |
6 | 13 | 105.16 | 18 | 15.29 | 461 | 127 | 3.39 / 115.57 | 2 | 14 |
7 | 8 | 0.36 | 165 | 15.27 | 307 | 774 | 4.16 / 116.34 | 2 | 18 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 30 | 15.24 | 457 | 209 | 0.21 / 108.43 | 2 | 4 |
2 | 7 | 1704.00 | 38 | 14.97 | 2594 | 1476 | 1.68 / 109.91 | 2 | 17 |
3 | 13 | 1665.20 | 18 | 14.95 | 2569 | 691 | 2.38 / 110.60 | 2 | 16 |
4 | 13 | 850.48 | 18 | 15.11 | 1541 | 419 | 2.80 / 111.02 | 2 | 18 |
5 | 13 | 329.84 | 18 | 15.24 | 820 | 225 | 3.02 / 111.24 | 2 | 18 |
6 | 13 | 117.64 | 18 | 15.30 | 482 | 133 | 3.15 / 111.38 | 2 | 15 |
7 | 8 | 0.04 | 165 | 15.28 | 318 | 802 | 3.95 / 112.18 | 2 | 18 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 30 | 15.24 | 454 | 208 | 0.21 / 104.41 | 2 | 4 |
2 | 7 | 2008.04 | 38 | 14.88 | 2980 | 1685 | 1.89 / 106.09 | 2 | 14 |
3 | 13 | 1357.68 | 18 | 15.01 | 2198 | 594 | 2.49 / 106.69 | 2 | 18 |
4 | 13 | 887.56 | 18 | 15.09 | 1589 | 432 | 2.92 / 107.12 | 2 | 19 |
5 | 13 | 260.48 | 18 | 15.26 | 705 | 194 | 3.11 / 107.31 | 2 | 18 |
6 | 13 | 103.08 | 18 | 15.30 | 469 | 129 | 3.24 / 107.44 | 2 | 15 |
7 | 8 | 0.12 | 165 | 15.28 | 311 | 784 | 4.02 / 108.22 | 2 | 21 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 30 | 15.23 | 461 | 211 | 0.21 / 100.25 | 2 | 4 |
2 | 7 | 2003.84 | 39 | 14.89 | 2994 | 1739 | 1.95 / 101.99 | 2 | 15 |
3 | 13 | 1457.20 | 18 | 14.99 | 2320 | 626 | 2.58 / 102.61 | 2 | 18 |
4 | 13 | 913.52 | 18 | 15.08 | 1628 | 442 | 3.02 / 103.05 | 2 | 19 |
5 | 13 | 362.16 | 18 | 15.23 | 852 | 234 | 3.25 / 103.29 | 2 | 19 |
6 | 13 | 100.28 | 18 | 15.29 | 460 | 127 | 3.38 / 103.41 | 2 | 14 |
7 | 8 | 0.04 | 165 | 15.27 | 312 | 786 | 4.16 / 104.20 | 2 | 20 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 30 | 15.24 | 456 | 208 | 0.21 / 95.99 | 2 | 4 |
2 | 3 | 1019.36 | 1 | 15.28 | 1765 | 27 | 0.24 / 96.01 | 2 | 13 |
3 | 7 | 2010.36 | 38 | 14.90 | 3003 | 1700 | 1.94 / 97.71 | 2 | 14 |
4 | 13 | 1569.24 | 18 | 14.97 | 2473 | 666 | 2.60 / 98.38 | 2 | 19 |
5 | 13 | 955.36 | 18 | 15.08 | 1663 | 451 | 3.05 / 98.83 | 2 | 20 |
6 | 13 | 447.24 | 18 | 15.22 | 982 | 269 | 3.32 / 99.10 | 2 | 20 |
7 | 13 | 110.76 | 18 | 15.30 | 467 | 129 | 3.45 / 99.23 | 2 | 15 |
8 | 8 | 0.24 | 165 | 15.28 | 320 | 807 | 4.26 / 100.04 | 2 | 14 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 30 | 15.22 | 464 | 212 | 0.21 / 91.86 | 2 | 4 |
2 | 7 | 2009.28 | 38 | 14.89 | 2974 | 1683 | 1.89 / 93.54 | 2 | 16 |
3 | 13 | 1504.32 | 18 | 14.99 | 2349 | 634 | 2.53 / 94.18 | 2 | 18 |
4 | 13 | 897.56 | 18 | 15.11 | 1569 | 427 | 2.96 / 94.60 | 2 | 18 |
5 | 13 | 406.80 | 18 | 15.21 | 913 | 250 | 3.21 / 94.85 | 2 | 18 |
6 | 13 | 122.64 | 18 | 15.29 | 491 | 135 | 3.34 / 94.99 | 2 | 16 |
7 | 8 | 0.16 | 165 | 15.28 | 313 | 789 | 4.13 / 95.78 | 2 | 19 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 30 | 15.24 | 452 | 207 | 0.21 / 87.70 | 2 | 5 |
2 | 7 | 2006.48 | 38 | 14.90 | 2998 | 1697 | 1.90 / 89.39 | 2 | 18 |
3 | 13 | 1446.36 | 18 | 15.00 | 2319 | 626 | 2.53 / 90.02 | 2 | 16 |
4 | 13 | 944.96 | 18 | 15.08 | 1652 | 448 | 2.98 / 90.47 | 2 | 21 |
5 | 13 | 400.88 | 18 | 15.23 | 893 | 245 | 3.22 / 90.71 | 2 | 19 |
6 | 13 | 71.64 | 18 | 15.30 | 424 | 117 | 3.34 / 90.83 | 2 | 14 |
7 | 8 | 0.04 | 165 | 15.27 | 325 | 819 | 4.16 / 91.65 | 2 | 19 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 30 | 15.26 | 448 | 205 | 0.21 / 83.51 | 2 | 5 |
2 | 7 | 2003.40 | 38 | 14.91 | 2967 | 1681 | 1.89 / 85.19 | 2 | 18 |
3 | 13 | 1493.80 | 18 | 15.00 | 2347 | 634 | 2.52 / 85.82 | 2 | 17 |
4 | 13 | 900.28 | 18 | 15.10 | 1578 | 429 | 2.95 / 86.25 | 2 | 20 |
5 | 13 | 507.00 | 18 | 15.20 | 1047 | 286 | 3.24 / 86.54 | 2 | 20 |
6 | 13 | 107.72 | 18 | 15.31 | 473 | 130 | 3.37 / 86.67 | 2 | 15 |
7 | 8 | -0.32 | 165 | 15.28 | 326 | 822 | 4.19 / 87.49 | 2 | 23 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 30 | 15.27 | 442 | 202 | 0.20 / 79.44 | 2 | 4 |
2 | 7 | 2006.60 | 38 | 14.91 | 2977 | 1687 | 1.89 / 81.13 | 2 | 14 |
3 | 13 | 1449.28 | 18 | 15.02 | 2286 | 618 | 2.51 / 81.75 | 2 | 19 |
4 | 13 | 994.80 | 18 | 15.08 | 1696 | 460 | 2.97 / 82.21 | 2 | 20 |
5 | 13 | 465.92 | 18 | 15.22 | 981 | 269 | 3.24 / 82.48 | 2 | 21 |
6 | 13 | 116.56 | 18 | 15.30 | 452 | 124 | 3.36 / 82.60 | 2 | 16 |
7 | 8 | 0.12 | 165 | 15.30 | 278 | 702 | 4.06 / 83.30 | 2 | 18 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 30 | 15.25 | 444 | 203 | 0.20 / 75.46 | 2 | 4 |
2 | 7 | 2003.88 | 38 | 14.92 | 2971 | 1684 | 1.89 / 77.14 | 2 | 17 |
3 | 13 | 1467.16 | 18 | 15.00 | 2315 | 625 | 2.51 / 77.77 | 2 | 17 |
4 | 13 | 851.40 | 18 | 15.12 | 1517 | 413 | 2.93 / 78.18 | 2 | 19 |
5 | 13 | 354.56 | 18 | 15.25 | 811 | 223 | 3.15 / 78.40 | 2 | 19 |
6 | 13 | 93.40 | 18 | 15.32 | 412 | 114 | 3.26 / 78.52 | 2 | 14 |
7 | 8 | 0.04 | 165 | 15.30 | 287 | 725 | 3.99 / 79.24 | 2 | 18 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 30 | 15.26 | 440 | 201 | 0.20 / 71.36 | 2 | 4 |
2 | 7 | 2003.48 | 38 | 14.92 | 2971 | 1684 | 1.89 / 73.04 | 2 | 14 |
3 | 13 | 1436.16 | 18 | 15.02 | 2257 | 610 | 2.50 / 73.65 | 2 | 17 |
4 | 13 | 848.08 | 18 | 15.13 | 1507 | 410 | 2.91 / 74.06 | 2 | 20 |
5 | 13 | 465.68 | 18 | 15.21 | 983 | 269 | 3.18 / 74.33 | 2 | 21 |
6 | 13 | 118.60 | 18 | 15.31 | 472 | 130 | 3.31 / 74.46 | 2 | 16 |
7 | 8 | 0.00 | 165 | 15.28 | 314 | 792 | 4.10 / 75.25 | 2 | 22 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 30 | 15.26 | 455 | 208 | 0.21 / 67.15 | 2 | 5 |
2 | 7 | 2013.84 | 39 | 14.93 | 2986 | 1739 | 1.95 / 68.89 | 2 | 14 |
3 | 13 | 1477.80 | 18 | 15.01 | 2323 | 628 | 2.57 / 69.52 | 2 | 17 |
4 | 13 | 984.68 | 18 | 15.11 | 1698 | 462 | 3.04 / 69.98 | 2 | 19 |
5 | 13 | 397.84 | 18 | 15.25 | 883 | 242 | 3.28 / 70.22 | 2 | 20 |
6 | 13 | 110.72 | 18 | 15.31 | 470 | 130 | 3.41 / 70.35 | 2 | 15 |
7 | 8 | -0.16 | 165 | 15.29 | 320 | 807 | 4.22 / 71.16 | 2 | 21 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 30 | 15.27 | 442 | 202 | 0.20 / 62.85 | 2 | 4 |
2 | 7 | 2012.80 | 38 | 14.93 | 2984 | 1693 | 1.90 / 64.54 | 2 | 13 |
3 | 13 | 1573.96 | 18 | 15.00 | 2439 | 659 | 2.55 / 65.20 | 2 | 18 |
4 | 13 | 960.60 | 18 | 15.10 | 1656 | 450 | 3.00 / 65.65 | 2 | 19 |
5 | 13 | 407.76 | 18 | 15.24 | 892 | 245 | 3.25 / 65.89 | 2 | 21 |
6 | 13 | 123.12 | 18 | 15.31 | 465 | 128 | 3.38 / 66.02 | 2 | 16 |
7 | 8 | 0.08 | 165 | 15.30 | 307 | 775 | 4.15 / 66.80 | 2 | 21 |
8 | 14 | 0.08 | 30 | 15.27 | 314 | 144 | 4.30 / 66.94 | 3 | 17 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 29 | 15.25 | 466 | 206 | 0.21 / 58.76 | 2 | 5 |
2 | 7 | 2005.92 | 38 | 14.93 | 2980 | 1691 | 1.90 / 60.45 | 2 | 14 |
3 | 13 | 1452.48 | 18 | 15.02 | 2307 | 624 | 2.52 / 61.07 | 2 | 17 |
4 | 13 | 863.64 | 18 | 15.13 | 1560 | 425 | 2.95 / 61.50 | 2 | 19 |
5 | 13 | 371.28 | 18 | 15.25 | 870 | 239 | 3.18 / 61.73 | 2 | 19 |
6 | 13 | 85.92 | 18 | 15.32 | 438 | 121 | 3.30 / 61.85 | 2 | 14 |
7 | 8 | 0.00 | 165 | 15.30 | 313 | 790 | 4.10 / 62.65 | 2 | 19 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 29 | 15.26 | 457 | 202 | 0.20 / 54.61 | 2 | 4 |
2 | 7 | 2010.44 | 38 | 14.92 | 2981 | 1690 | 1.89 / 56.30 | 2 | 17 |
3 | 13 | 1420.00 | 18 | 15.02 | 2273 | 615 | 2.51 / 56.92 | 2 | 17 |
4 | 13 | 878.12 | 18 | 15.11 | 1579 | 429 | 2.94 / 57.35 | 2 | 18 |
5 | 13 | 417.36 | 18 | 15.22 | 944 | 259 | 3.19 / 57.61 | 2 | 20 |
6 | 13 | 79.52 | 18 | 15.32 | 439 | 121 | 3.32 / 57.73 | 2 | 14 |
7 | 8 | -0.12 | 165 | 15.29 | 326 | 822 | 4.14 / 58.55 | 2 | 20 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 29 | 15.28 | 405 | 179 | 0.18 / 50.48 | 2 | 5 |
2 | 7 | 2013.76 | 38 | 14.93 | 2983 | 1692 | 1.87 / 52.17 | 2 | 17 |
3 | 13 | 1429.04 | 18 | 15.03 | 2264 | 613 | 2.48 / 52.78 | 2 | 17 |
4 | 13 | 948.60 | 18 | 15.11 | 1635 | 445 | 2.93 / 53.23 | 2 | 21 |
5 | 13 | 348.44 | 18 | 15.26 | 805 | 221 | 3.15 / 53.45 | 2 | 19 |
6 | 13 | 83.64 | 18 | 15.34 | 410 | 113 | 3.26 / 53.56 | 2 | 15 |
7 | 8 | -0.28 | 165 | 15.32 | 282 | 713 | 3.98 / 54.28 | 2 | 18 |
8 | 14 | -0.28 | 30 | 15.29 | 295 | 135 | 4.11 / 54.41 | 2 | 18 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 29 | 15.28 | 407 | 180 | 0.18 / 46.53 | 2 | 4 |
2 | 7 | 2010.00 | 38 | 14.94 | 2980 | 1692 | 1.87 / 48.22 | 2 | 14 |
3 | 13 | 1416.84 | 18 | 15.02 | 2248 | 608 | 2.48 / 48.83 | 2 | 17 |
4 | 13 | 935.24 | 18 | 15.11 | 1624 | 442 | 2.92 / 49.27 | 2 | 20 |
5 | 13 | 343.28 | 18 | 15.27 | 801 | 220 | 3.14 / 49.49 | 2 | 18 |
6 | 13 | 81.60 | 18 | 15.33 | 403 | 111 | 3.25 / 49.60 | 2 | 14 |
7 | 8 | 0.16 | 165 | 15.31 | 276 | 697 | 3.95 / 50.30 | 2 | 20 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 29 | 15.26 | 414 | 183 | 0.18 / 42.03 | 2 | 5 |
2 | 7 | 2005.12 | 74 | 14.82 | 2958 | 3244 | 3.43 / 45.27 | 2 | 18 |
3 | 13 | 436.60 | 18 | 15.25 | 933 | 256 | 3.68 / 45.53 | 2 | 19 |
4 | 13 | 109.24 | 18 | 15.33 | 443 | 122 | 3.81 / 45.65 | 2 | 15 |
5 | 8 | -0.12 | 165 | 15.32 | 276 | 698 | 4.50 / 46.35 | 2 | 20 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 29 | 15.27 | 422 | 187 | 0.19 / 37.36 | 2 | 5 |
2 | 7 | 2007.64 | 74 | 14.83 | 2957 | 3245 | 3.43 / 40.61 | 2 | 15 |
3 | 13 | 603.44 | 18 | 15.20 | 1173 | 321 | 3.75 / 40.93 | 2 | 23 |
4 | 13 | 134.56 | 18 | 15.33 | 480 | 132 | 3.89 / 41.06 | 2 | 15 |
5 | 13 | 16.88 | 18 | 15.34 | 307 | 85 | 3.97 / 41.15 | 2 | 14 |
6 | 8 | 0.08 | 165 | 15.31 | 277 | 700 | 4.67 / 41.85 | 2 | 20 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 29 | 15.28 | 417 | 185 | 0.18 / 32.80 | 2 | 4 |
2 | 3 | 1018.36 | 1 | 15.32 | 1794 | 27 | 0.21 / 32.83 | 2 | 12 |
3 | 7 | 2010.80 | 74 | 14.82 | 2964 | 3251 | 3.46 / 36.08 | 2 | 14 |
4 | 13 | 494.20 | 18 | 15.23 | 1018 | 279 | 3.74 / 36.36 | 2 | 21 |
5 | 13 | 107.68 | 18 | 15.33 | 447 | 123 | 3.87 / 36.48 | 2 | 14 |
6 | 8 | -0.12 | 165 | 15.31 | 276 | 697 | 4.56 / 37.18 | 2 | 18 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 30 | 15.28 | 409 | 187 | 0.19 / 28.26 | 2 | 4 |
2 | 3 | 962.64 | -1 | 15.61 | 0 | 0 | 0.00 / 28.26 | 2 | 4 |
3 | 7 | 2005.68 | 74 | 14.82 | 2953 | 3238 | 3.43 / 31.50 | 2 | 14 |
4 | 13 | 560.80 | 18 | 15.20 | 1113 | 305 | 3.73 / 31.80 | 2 | 20 |
5 | 13 | 107.44 | 18 | 15.33 | 433 | 119 | 3.85 / 31.92 | 2 | 14 |
6 | 8 | 0.12 | 165 | 15.32 | 275 | 695 | 4.55 / 32.61 | 2 | 17 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 29 | 15.29 | 416 | 184 | 0.18 / 24.10 | 2 | 4 |
2 | 7 | 1773.92 | 74 | 14.90 | 2659 | 2932 | 3.12 / 27.03 | 2 | 13 |
3 | 13 | 369.24 | 18 | 15.27 | 833 | 229 | 3.35 / 27.26 | 2 | 18 |
4 | 13 | 101.56 | 18 | 15.34 | 427 | 118 | 3.46 / 27.38 | 2 | 13 |
5 | 8 | -0.04 | 165 | 15.32 | 273 | 690 | 4.15 / 28.07 | 2 | 21 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 28 | 15.28 | 427 | 183 | 0.18 / 19.93 | 2 | 3 |
2 | 3 | 1025.24 | 1 | 15.32 | 1783 | 27 | 0.21 / 19.96 | 2 | 11 |
3 | 7 | 1765.48 | 74 | 14.90 | 2651 | 2923 | 3.13 / 22.88 | 2 | 13 |
4 | 13 | 335.00 | 18 | 15.28 | 779 | 214 | 3.35 / 23.10 | 2 | 17 |
5 | 13 | 115.04 | 18 | 15.33 | 452 | 125 | 3.47 / 23.22 | 2 | 14 |
6 | 8 | -0.20 | 165 | 15.33 | 275 | 696 | 4.17 / 23.92 | 2 | 12 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 28 | 15.29 | 424 | 182 | 0.18 / 15.81 | 2 | 3 |
2 | 7 | 1773.92 | 74 | 14.90 | 2662 | 2935 | 3.12 / 18.75 | 2 | 14 |
3 | 13 | 312.48 | 18 | 15.29 | 741 | 204 | 3.32 / 18.95 | 2 | 17 |
4 | 13 | 96.00 | 18 | 15.34 | 420 | 116 | 3.44 / 19.07 | 2 | 13 |
5 | 8 | 0.16 | 165 | 15.32 | 270 | 683 | 4.12 / 19.75 | 2 | 20 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 28 | 15.30 | 421 | 180 | 0.18 / 12.03 | 2 | 3 |
2 | 7 | 1511.76 | 74 | 14.99 | 2327 | 2581 | 2.76 / 14.62 | 2 | 14 |
3 | 13 | 309.84 | 18 | 15.30 | 739 | 204 | 2.97 / 14.82 | 2 | 16 |
4 | 13 | 92.72 | 18 | 15.35 | 416 | 115 | 3.08 / 14.93 | 2 | 13 |
5 | 8 | 0.12 | 165 | 15.33 | 275 | 696 | 3.78 / 15.63 | 2 | 16 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 28 | 15.28 | 420 | 180 | 0.18 / 8.24 | 2 | 3 |
2 | 7 | 1526.24 | 74 | 14.99 | 2345 | 2601 | 2.78 / 10.84 | 2 | 14 |
3 | 13 | 300.48 | 18 | 15.32 | 729 | 201 | 2.98 / 11.04 | 2 | 16 |
4 | 13 | 95.00 | 18 | 15.35 | 418 | 115 | 3.10 / 11.16 | 2 | 13 |
5 | 8 | 0.16 | 165 | 15.34 | 275 | 696 | 3.79 / 11.85 | 2 | 17 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 33 | 15.31 | 416 | 210 | 0.21 / 4.45 | 2 | 4 |
2 | 3 | 840.32 | -3 | 15.63 | 0 | 0 | 0.00 / 4.45 | 2 | 4 |
3 | 3 | 964.28 | -1 | 15.66 | 0 | 0 | 0.00 / 4.45 | 2 | 4 |
4 | 7 | 1510.28 | 74 | 15.00 | 2325 | 2581 | 2.79 / 7.03 | 2 | 14 |
5 | 13 | 354.64 | 18 | 15.29 | 812 | 223 | 3.01 / 7.26 | 2 | 17 |
6 | 13 | 83.20 | 18 | 15.35 | 401 | 111 | 3.13 / 7.37 | 2 | 13 |
7 | 8 | 0.04 | 165 | 15.33 | 274 | 693 | 3.82 / 8.06 | 2 | 16 |
Average= | 2.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 28 | 15.49 | 388 | 168 | 0.17 / 1.65 | 2 | 3 |
2 | 7 | 1001.12 | 75 | 15.16 | 1660 | 1887 | 2.06 / 3.54 | 2 | 17 |
3 | 8 | 0.12 | 165 | 15.36 | 277 | 702 | 2.76 / 4.24 | 2 | 17 |
Average= | 2.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 64.28 | 27 | 15.63 | 355 | 150 | 0.15 / 0.15 | 2 | 3 |
2 | 7 | 83.28 | 74 | 15.61 | 376 | 434 | 0.58 / 0.58 | 2 | 6 |
3 | 8 | 0.24 | 240 | 15.56 | 241 | 900 | 1.48 / 1.48 | 2 | 19 |
Average= | 1.48 (KJ/cycle) |