SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 19 | 15.12 | 458 | 132 | 0.13 / 239.60 | 2 | 5 |
2 | 7 | 2003.76 | 38 | 14.80 | 2891 | 1626 | 1.76 / 241.23 | 2 | 13 |
3 | 13 | 1518.08 | 18 | 14.87 | 2309 | 618 | 2.38 / 241.85 | 2 | 14 |
4 | 13 | 973.80 | 18 | 14.97 | 1616 | 435 | 2.81 / 242.28 | 2 | 16 |
5 | 13 | 417.32 | 18 | 15.09 | 888 | 241 | 3.05 / 242.52 | 2 | 18 |
6 | 13 | 82.52 | 18 | 15.16 | 413 | 113 | 3.16 / 242.64 | 2 | 9 |
7 | 8 | -0.04 | 165 | 15.13 | 301 | 751 | 3.92 / 243.39 | 2 | 15 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.40 | 19 | 15.11 | 458 | 131 | 0.13 / 235.59 | 2 | 6 |
2 | 7 | 2006.84 | 38 | 14.81 | 2903 | 1634 | 1.77 / 237.23 | 2 | 14 |
3 | 13 | 1517.32 | 18 | 14.88 | 2314 | 620 | 2.39 / 237.85 | 2 | 14 |
4 | 13 | 1085.68 | 18 | 14.94 | 1757 | 472 | 2.86 / 238.32 | 2 | 19 |
5 | 13 | 490.00 | 18 | 15.07 | 990 | 269 | 3.13 / 238.59 | 2 | 18 |
6 | 13 | 113.84 | 18 | 15.15 | 463 | 126 | 3.25 / 238.71 | 2 | 10 |
7 | 8 | 0.08 | 165 | 15.13 | 304 | 759 | 4.01 / 239.47 | 2 | 21 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 19 | 15.12 | 426 | 122 | 0.12 / 231.58 | 2 | 3 |
2 | 3 | 1381.32 | -1 | 15.45 | 0 | 0 | 0.00 / 231.58 | 2 | 3 |
3 | 3 | 1424.60 | 1 | 15.08 | 2275 | 34 | 0.16 / 231.61 | 2 | 15 |
4 | 7 | 2004.24 | 38 | 14.80 | 2889 | 1625 | 1.78 / 233.24 | 2 | 14 |
5 | 13 | 1526.88 | 18 | 14.87 | 2321 | 621 | 2.40 / 233.86 | 2 | 14 |
6 | 13 | 1090.04 | 18 | 14.94 | 1773 | 477 | 2.88 / 234.34 | 2 | 18 |
7 | 13 | 474.12 | 18 | 15.07 | 964 | 261 | 3.14 / 234.60 | 2 | 18 |
8 | 13 | 83.20 | 18 | 15.15 | 420 | 115 | 3.26 / 234.71 | 2 | 4 |
9 | 8 | 0.08 | 165 | 15.14 | 299 | 747 | 4.00 / 235.46 | 2 | 11 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.68 | 19 | 15.12 | 447 | 128 | 0.13 / 227.70 | 2 | 4 |
2 | 7 | 2005.80 | 38 | 14.82 | 2890 | 1628 | 1.76 / 229.33 | 2 | 11 |
3 | 13 | 1471.40 | 18 | 14.89 | 2250 | 603 | 2.36 / 229.93 | 2 | 16 |
4 | 13 | 994.60 | 18 | 14.97 | 1635 | 441 | 2.80 / 230.37 | 2 | 19 |
5 | 13 | 457.16 | 18 | 15.08 | 926 | 251 | 3.05 / 230.62 | 2 | 17 |
6 | 13 | 81.12 | 18 | 15.18 | 408 | 111 | 3.16 / 230.73 | 2 | 18 |
7 | 8 | 0.12 | 165 | 15.15 | 290 | 725 | 3.89 / 231.46 | 2 | 2 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 19 | 15.13 | 444 | 128 | 0.13 / 223.77 | 2 | 6 |
2 | 7 | 2011.88 | 38 | 14.81 | 2893 | 1628 | 1.76 / 225.40 | 2 | 13 |
3 | 13 | 1572.88 | 18 | 14.86 | 2367 | 633 | 2.39 / 226.03 | 2 | 13 |
4 | 13 | 1018.00 | 18 | 14.96 | 1671 | 450 | 2.84 / 226.48 | 2 | 18 |
5 | 13 | 468.48 | 18 | 15.09 | 940 | 255 | 3.09 / 226.74 | 2 | 16 |
6 | 13 | 46.36 | 18 | 15.18 | 366 | 100 | 3.19 / 226.84 | 2 | 17 |
7 | 8 | 0.08 | 165 | 15.15 | 294 | 735 | 3.93 / 227.57 | 2 | 3 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 19 | 15.12 | 447 | 128 | 0.13 / 219.84 | 2 | 6 |
2 | 7 | 2009.40 | 38 | 14.81 | 2894 | 1629 | 1.76 / 221.47 | 2 | 16 |
3 | 13 | 1574.80 | 18 | 14.88 | 2376 | 636 | 2.39 / 222.11 | 2 | 15 |
4 | 13 | 984.88 | 18 | 14.98 | 1629 | 439 | 2.83 / 222.55 | 2 | 16 |
5 | 13 | 402.60 | 18 | 15.12 | 856 | 233 | 3.07 / 222.78 | 2 | 17 |
6 | 13 | 129.28 | 18 | 15.16 | 473 | 129 | 3.19 / 222.91 | 2 | 14 |
7 | 8 | 0.04 | 165 | 15.15 | 293 | 732 | 3.93 / 223.64 | 2 | 9 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 19 | 15.12 | 447 | 128 | 0.13 / 215.90 | 2 | 3 |
2 | 7 | 2006.16 | 38 | 14.82 | 2883 | 1624 | 1.75 / 217.53 | 2 | 10 |
3 | 13 | 1515.84 | 18 | 14.89 | 2297 | 616 | 2.37 / 218.14 | 2 | 17 |
4 | 13 | 1000.76 | 18 | 14.98 | 1649 | 445 | 2.81 / 218.59 | 2 | 17 |
5 | 13 | 460.16 | 18 | 15.10 | 949 | 258 | 3.07 / 218.85 | 2 | 17 |
6 | 13 | 126.00 | 18 | 15.16 | 473 | 129 | 3.20 / 218.97 | 2 | 10 |
7 | 8 | 0.04 | 165 | 15.15 | 296 | 740 | 3.94 / 219.71 | 2 | 8 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 19 | 15.13 | 453 | 130 | 0.13 / 211.90 | 2 | 2 |
2 | 7 | 2003.04 | 39 | 14.80 | 2897 | 1672 | 1.80 / 213.57 | 2 | 10 |
3 | 13 | 1565.24 | 18 | 14.88 | 2369 | 635 | 2.44 / 214.21 | 2 | 15 |
4 | 13 | 1011.16 | 18 | 14.97 | 1664 | 448 | 2.89 / 214.66 | 2 | 15 |
5 | 13 | 419.68 | 18 | 15.10 | 884 | 240 | 3.13 / 214.90 | 2 | 18 |
6 | 13 | 145.52 | 18 | 15.16 | 506 | 138 | 3.26 / 215.04 | 2 | 14 |
7 | 8 | 0.12 | 165 | 15.15 | 296 | 740 | 4.00 / 215.77 | 2 | 31 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 19 | 15.13 | 460 | 132 | 0.13 / 207.95 | 2 | 4 |
2 | 7 | 2012.32 | 39 | 14.82 | 2901 | 1677 | 1.81 / 209.63 | 2 | 12 |
3 | 13 | 1483.80 | 18 | 14.90 | 2268 | 608 | 2.42 / 210.23 | 2 | 16 |
4 | 13 | 951.60 | 18 | 14.98 | 1587 | 428 | 2.85 / 210.66 | 2 | 18 |
5 | 13 | 412.68 | 18 | 15.11 | 880 | 239 | 3.08 / 210.90 | 2 | 16 |
6 | 13 | 83.64 | 18 | 15.18 | 422 | 115 | 3.20 / 211.02 | 2 | 14 |
7 | 8 | 0.16 | 165 | 15.16 | 302 | 755 | 3.96 / 211.77 | 2 | 30 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 19 | 15.14 | 459 | 132 | 0.13 / 204.06 | 2 | 6 |
2 | 7 | 2003.88 | 38 | 14.82 | 2892 | 1629 | 1.76 / 205.69 | 2 | 13 |
3 | 13 | 1468.00 | 18 | 14.90 | 2250 | 603 | 2.36 / 206.29 | 2 | 17 |
4 | 13 | 889.84 | 18 | 15.01 | 1516 | 410 | 2.77 / 206.70 | 2 | 18 |
5 | 13 | 459.56 | 18 | 15.11 | 948 | 258 | 3.03 / 206.96 | 2 | 17 |
6 | 13 | 30.32 | 18 | 15.19 | 351 | 96 | 3.13 / 207.06 | 2 | 22 |
7 | 8 | 0.04 | 165 | 15.16 | 304 | 760 | 3.89 / 207.82 | 2 | 23 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 19 | 15.13 | 462 | 133 | 0.13 / 200.09 | 2 | 2 |
2 | 7 | 2009.32 | 38 | 14.81 | 2900 | 1632 | 1.76 / 201.72 | 2 | 13 |
3 | 13 | 1427.12 | 18 | 14.91 | 2206 | 592 | 2.36 / 202.31 | 2 | 15 |
4 | 13 | 996.52 | 18 | 14.98 | 1652 | 445 | 2.80 / 202.76 | 2 | 18 |
5 | 13 | 493.56 | 18 | 15.08 | 997 | 271 | 3.07 / 203.03 | 2 | 18 |
6 | 13 | 136.92 | 18 | 15.17 | 502 | 137 | 3.21 / 203.16 | 2 | 12 |
7 | 8 | 0.08 | 165 | 15.15 | 306 | 765 | 3.97 / 203.93 | 2 | 32 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.44 | 19 | 15.12 | 461 | 132 | 0.13 / 196.08 | 2 | 3 |
2 | 3 | 1385.56 | -1 | 15.45 | 0 | 0 | 0.00 / 196.08 | 2 | 3 |
3 | 3 | 1422.52 | 1 | 15.09 | 2238 | 34 | 0.17 / 196.11 | 2 | 13 |
4 | 7 | 2005.04 | 38 | 14.82 | 2896 | 1631 | 1.80 / 197.74 | 2 | 14 |
5 | 13 | 1522.48 | 18 | 14.90 | 2319 | 622 | 2.42 / 198.36 | 2 | 18 |
6 | 13 | 983.96 | 18 | 14.98 | 1629 | 439 | 2.86 / 198.80 | 2 | 19 |
7 | 13 | 489.36 | 18 | 15.10 | 992 | 270 | 3.13 / 199.07 | 2 | 20 |
8 | 13 | 84.80 | 18 | 15.18 | 428 | 117 | 3.24 / 199.19 | 2 | 18 |
9 | 8 | 0.12 | 165 | 15.15 | 306 | 765 | 4.01 / 199.95 | 2 | 31 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 19 | 15.13 | 447 | 128 | 0.13 / 192.09 | 2 | 4 |
2 | 3 | 1383.32 | -1 | 15.46 | 0 | 0 | 0.00 / 192.09 | 2 | 4 |
3 | 3 | 1422.52 | 1 | 15.09 | 2277 | 34 | 0.16 / 192.13 | 2 | 14 |
4 | 7 | 2002.68 | 38 | 14.83 | 2895 | 1631 | 1.79 / 193.76 | 2 | 15 |
5 | 13 | 1522.48 | 18 | 14.89 | 2329 | 624 | 2.42 / 194.38 | 2 | 17 |
6 | 13 | 963.64 | 18 | 15.00 | 1608 | 434 | 2.85 / 194.82 | 2 | 18 |
7 | 13 | 473.76 | 18 | 15.10 | 972 | 264 | 3.12 / 195.08 | 2 | 20 |
8 | 13 | 42.60 | 18 | 15.19 | 370 | 101 | 3.22 / 195.18 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.16 | 304 | 760 | 3.98 / 195.94 | 2 | 35 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 19 | 15.14 | 447 | 129 | 0.13 / 188.14 | 2 | 3 |
2 | 7 | 2008.68 | 38 | 14.82 | 2899 | 1633 | 1.76 / 189.77 | 2 | 11 |
3 | 13 | 1528.08 | 18 | 14.90 | 2328 | 624 | 2.39 / 190.40 | 2 | 15 |
4 | 13 | 981.44 | 18 | 14.99 | 1640 | 443 | 2.83 / 190.84 | 2 | 17 |
5 | 13 | 446.40 | 18 | 15.11 | 930 | 253 | 3.08 / 191.09 | 2 | 19 |
6 | 13 | 60.16 | 18 | 15.18 | 391 | 107 | 3.19 / 191.20 | 2 | 19 |
7 | 8 | 0.12 | 165 | 15.16 | 306 | 765 | 3.95 / 191.96 | 2 | 26 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 19 | 15.14 | 460 | 132 | 0.13 / 184.16 | 2 | 5 |
2 | 3 | 1379.80 | -1 | 15.46 | 0 | 0 | 0.00 / 184.16 | 2 | 5 |
3 | 3 | 1418.84 | 1 | 15.10 | 2254 | 34 | 0.17 / 184.19 | 2 | 14 |
4 | 7 | 2007.92 | 38 | 14.83 | 2905 | 1637 | 1.80 / 185.83 | 2 | 12 |
5 | 13 | 1470.04 | 18 | 14.91 | 2252 | 604 | 2.41 / 186.43 | 2 | 15 |
6 | 13 | 988.52 | 18 | 14.98 | 1634 | 441 | 2.85 / 186.87 | 2 | 17 |
7 | 13 | 440.08 | 18 | 15.11 | 926 | 252 | 3.10 / 187.12 | 2 | 19 |
8 | 13 | 102.00 | 18 | 15.18 | 447 | 122 | 3.22 / 187.25 | 2 | 9 |
9 | 8 | 0.00 | 165 | 15.16 | 306 | 765 | 3.99 / 188.01 | 2 | 14 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 19 | 15.15 | 452 | 130 | 0.13 / 180.16 | 2 | 2 |
2 | 3 | 1381.92 | -1 | 15.46 | 0 | 0 | 0.00 / 180.16 | 2 | 2 |
3 | 3 | 1422.84 | 1 | 15.08 | 2273 | 34 | 0.16 / 180.19 | 2 | 11 |
4 | 7 | 2005.96 | 38 | 14.83 | 2897 | 1633 | 1.80 / 181.82 | 2 | 12 |
5 | 13 | 1522.84 | 18 | 14.90 | 2309 | 619 | 2.42 / 182.44 | 2 | 15 |
6 | 13 | 1017.52 | 18 | 14.99 | 1680 | 453 | 2.87 / 182.90 | 2 | 16 |
7 | 13 | 412.48 | 18 | 15.12 | 886 | 241 | 3.11 / 183.14 | 2 | 16 |
8 | 13 | 77.92 | 18 | 15.18 | 423 | 116 | 3.23 / 183.25 | 2 | 14 |
9 | 8 | 0.32 | 165 | 15.17 | 308 | 771 | 4.00 / 184.02 | 2 | 20 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 19 | 15.14 | 460 | 132 | 0.13 / 176.20 | 2 | 4 |
2 | 3 | 1386.08 | -1 | 15.47 | 0 | 0 | 0.00 / 176.20 | 2 | 4 |
3 | 3 | 1417.80 | 1 | 15.13 | 2239 | 34 | 0.17 / 176.24 | 2 | 14 |
4 | 7 | 2007.48 | 38 | 14.83 | 2902 | 1635 | 1.80 / 177.87 | 2 | 12 |
5 | 13 | 1397.12 | 18 | 14.93 | 2160 | 580 | 2.38 / 178.45 | 2 | 16 |
6 | 13 | 1016.60 | 18 | 14.99 | 1678 | 453 | 2.83 / 178.90 | 2 | 20 |
7 | 13 | 469.32 | 18 | 15.11 | 962 | 262 | 3.10 / 179.17 | 2 | 18 |
8 | 13 | 65.96 | 18 | 15.19 | 396 | 108 | 3.20 / 179.27 | 2 | 18 |
9 | 8 | -0.04 | 165 | 15.16 | 301 | 753 | 3.96 / 180.03 | 2 | 10 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.24 | 19 | 15.15 | 462 | 133 | 0.13 / 172.20 | 2 | 3 |
2 | 7 | 2003.84 | 38 | 14.85 | 2902 | 1638 | 1.77 / 173.83 | 2 | 13 |
3 | 13 | 1625.84 | 18 | 14.88 | 2444 | 655 | 2.43 / 174.49 | 2 | 13 |
4 | 13 | 1069.32 | 18 | 14.98 | 1743 | 470 | 2.90 / 174.96 | 2 | 20 |
5 | 13 | 406.40 | 18 | 15.13 | 870 | 237 | 3.13 / 175.20 | 2 | 19 |
6 | 13 | 73.68 | 18 | 15.20 | 412 | 113 | 3.24 / 175.31 | 2 | 5 |
7 | 8 | 0.24 | 165 | 15.17 | 304 | 761 | 4.01 / 176.07 | 2 | 32 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.24 | 19 | 15.15 | 458 | 132 | 0.13 / 168.28 | 2 | 5 |
2 | 7 | 2007.64 | 38 | 14.84 | 2896 | 1633 | 1.76 / 169.91 | 2 | 14 |
3 | 13 | 1470.64 | 18 | 14.93 | 2244 | 603 | 2.37 / 170.52 | 2 | 15 |
4 | 13 | 971.00 | 18 | 15.01 | 1617 | 437 | 2.80 / 170.95 | 2 | 18 |
5 | 13 | 363.48 | 18 | 15.15 | 818 | 223 | 3.03 / 171.18 | 2 | 18 |
6 | 13 | 80.96 | 18 | 15.20 | 427 | 117 | 3.14 / 171.29 | 2 | 17 |
7 | 8 | 0.12 | 165 | 15.17 | 307 | 768 | 3.91 / 172.06 | 2 | 30 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 19 | 15.16 | 431 | 124 | 0.12 / 164.28 | 2 | 3 |
2 | 7 | 2003.84 | 38 | 14.84 | 2888 | 1629 | 1.75 / 165.91 | 2 | 13 |
3 | 13 | 1563.80 | 18 | 14.91 | 2362 | 634 | 2.39 / 166.55 | 2 | 15 |
4 | 13 | 1011.20 | 18 | 15.00 | 1669 | 451 | 2.84 / 167.00 | 2 | 16 |
5 | 13 | 458.60 | 18 | 15.13 | 952 | 259 | 3.10 / 167.26 | 2 | 19 |
6 | 13 | 110.28 | 18 | 15.20 | 463 | 127 | 3.22 / 167.38 | 2 | 14 |
7 | 8 | 0.04 | 165 | 15.17 | 306 | 766 | 3.99 / 168.15 | 2 | 26 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 19 | 15.15 | 435 | 125 | 0.13 / 160.30 | 2 | 3 |
2 | 3 | 1375.44 | -1 | 15.47 | 0 | 0 | 0.00 / 160.30 | 2 | 3 |
3 | 3 | 1423.12 | 1 | 15.11 | 2291 | 35 | 0.16 / 160.34 | 2 | 12 |
4 | 7 | 2005.56 | 38 | 14.86 | 2900 | 1638 | 1.80 / 161.98 | 2 | 14 |
5 | 13 | 1517.36 | 18 | 14.93 | 2317 | 623 | 2.42 / 162.60 | 2 | 16 |
6 | 13 | 977.08 | 18 | 15.01 | 1633 | 441 | 2.86 / 163.04 | 2 | 18 |
7 | 13 | 437.96 | 18 | 15.13 | 917 | 250 | 3.11 / 163.29 | 2 | 19 |
8 | 13 | 112.36 | 18 | 15.19 | 457 | 125 | 3.24 / 163.41 | 2 | 15 |
9 | 8 | -0.48 | 165 | 15.18 | 298 | 746 | 3.98 / 164.16 | 2 | 9 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 19 | 15.15 | 424 | 122 | 0.12 / 156.37 | 2 | 3 |
2 | 7 | 2004.56 | 38 | 14.84 | 2890 | 1630 | 1.75 / 158.00 | 2 | 15 |
3 | 13 | 1567.36 | 18 | 14.92 | 2366 | 635 | 2.39 / 158.63 | 2 | 15 |
4 | 13 | 990.00 | 18 | 15.00 | 1634 | 441 | 2.83 / 159.08 | 2 | 15 |
5 | 13 | 403.20 | 18 | 15.14 | 872 | 238 | 3.07 / 159.31 | 2 | 18 |
6 | 13 | 84.40 | 18 | 15.20 | 426 | 117 | 3.18 / 159.43 | 2 | 17 |
7 | 8 | 0.28 | 165 | 15.18 | 299 | 749 | 3.93 / 160.18 | 2 | 3 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 19 | 15.15 | 426 | 123 | 0.12 / 152.41 | 2 | 6 |
2 | 7 | 2003.76 | 39 | 14.85 | 2891 | 1674 | 1.80 / 154.09 | 2 | 13 |
3 | 13 | 1478.64 | 18 | 14.92 | 2261 | 607 | 2.40 / 154.69 | 2 | 18 |
4 | 13 | 986.04 | 18 | 15.00 | 1634 | 441 | 2.85 / 155.13 | 2 | 19 |
5 | 13 | 440.84 | 18 | 15.13 | 922 | 251 | 3.10 / 155.38 | 2 | 18 |
6 | 13 | 61.64 | 18 | 15.21 | 395 | 108 | 3.20 / 155.49 | 2 | 13 |
7 | 8 | 0.32 | 165 | 15.18 | 301 | 754 | 3.96 / 156.25 | 2 | 30 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 19 | 15.16 | 458 | 132 | 0.13 / 148.44 | 2 | 2 |
2 | 7 | 2011.72 | 38 | 14.85 | 2901 | 1637 | 1.77 / 150.08 | 2 | 13 |
3 | 13 | 1543.52 | 18 | 14.91 | 2333 | 626 | 2.40 / 150.70 | 2 | 17 |
4 | 13 | 1001.36 | 18 | 15.01 | 1659 | 448 | 2.84 / 151.15 | 2 | 19 |
5 | 13 | 457.92 | 18 | 15.13 | 954 | 260 | 3.10 / 151.41 | 2 | 19 |
6 | 13 | 113.20 | 18 | 15.20 | 463 | 127 | 3.23 / 151.54 | 2 | 17 |
7 | 8 | 0.36 | 165 | 15.18 | 299 | 749 | 3.98 / 152.29 | 2 | 26 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.96 | 19 | 15.17 | 450 | 130 | 0.13 / 144.44 | 2 | 3 |
2 | 7 | 2005.32 | 38 | 14.85 | 2912 | 1643 | 1.77 / 146.08 | 2 | 12 |
3 | 13 | 1588.64 | 18 | 14.90 | 2407 | 646 | 2.42 / 146.73 | 2 | 15 |
4 | 13 | 984.80 | 18 | 15.01 | 1639 | 443 | 2.86 / 147.17 | 2 | 19 |
5 | 13 | 444.20 | 18 | 15.14 | 927 | 253 | 3.11 / 147.42 | 2 | 19 |
6 | 13 | 110.44 | 18 | 15.21 | 463 | 127 | 3.24 / 147.55 | 2 | 18 |
7 | 8 | 0.24 | 165 | 15.19 | 304 | 762 | 4.00 / 148.31 | 2 | 11 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 19 | 15.17 | 435 | 125 | 0.13 / 140.50 | 2 | 3 |
2 | 3 | 1385.32 | -1 | 15.49 | 0 | 0 | 0.00 / 140.50 | 2 | 3 |
3 | 3 | 1425.56 | 1 | 15.13 | 2265 | 34 | 0.16 / 140.54 | 2 | 13 |
4 | 7 | 2012.24 | 38 | 14.86 | 2916 | 1647 | 1.81 / 142.19 | 2 | 12 |
5 | 13 | 1478.68 | 18 | 14.95 | 2275 | 612 | 2.42 / 142.80 | 2 | 14 |
6 | 13 | 904.12 | 18 | 15.05 | 1544 | 418 | 2.84 / 143.22 | 2 | 18 |
7 | 13 | 341.48 | 18 | 15.16 | 791 | 216 | 3.05 / 143.43 | 2 | 17 |
8 | 13 | 73.40 | 18 | 15.22 | 414 | 113 | 3.17 / 143.55 | 2 | 20 |
9 | 8 | 0.16 | 165 | 15.19 | 304 | 762 | 3.93 / 144.31 | 2 | 4 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 19 | 15.16 | 438 | 126 | 0.13 / 136.51 | 2 | 4 |
2 | 3 | 1378.16 | -1 | 15.49 | 0 | 0 | 0.00 / 136.51 | 2 | 4 |
3 | 3 | 1424.76 | 1 | 15.12 | 2288 | 35 | 0.16 / 136.54 | 2 | 12 |
4 | 7 | 2011.24 | 38 | 14.86 | 2910 | 1643 | 1.80 / 138.19 | 2 | 14 |
5 | 13 | 1481.88 | 18 | 14.94 | 2261 | 608 | 2.41 / 138.79 | 2 | 16 |
6 | 13 | 987.72 | 18 | 15.02 | 1642 | 444 | 2.86 / 139.24 | 2 | 18 |
7 | 13 | 481.32 | 18 | 15.13 | 977 | 266 | 3.12 / 139.50 | 2 | 20 |
8 | 13 | 83.64 | 18 | 15.22 | 429 | 118 | 3.24 / 139.62 | 2 | 15 |
9 | 8 | 0.12 | 165 | 15.19 | 302 | 757 | 4.00 / 140.38 | 2 | 26 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 19 | 15.16 | 425 | 122 | 0.12 / 132.55 | 2 | 4 |
2 | 3 | 1385.32 | -1 | 15.50 | 0 | 0 | 0.00 / 132.55 | 2 | 4 |
3 | 3 | 1420.80 | 1 | 15.14 | 2286 | 35 | 0.16 / 132.58 | 2 | 11 |
4 | 7 | 2007.32 | 39 | 14.86 | 2908 | 1685 | 1.84 / 134.27 | 2 | 12 |
5 | 13 | 1478.04 | 18 | 14.95 | 2258 | 608 | 2.45 / 134.88 | 2 | 15 |
6 | 13 | 930.88 | 18 | 15.04 | 1566 | 424 | 2.87 / 135.30 | 2 | 16 |
7 | 13 | 343.36 | 18 | 15.17 | 784 | 214 | 3.09 / 135.51 | 2 | 19 |
8 | 13 | 80.44 | 18 | 15.22 | 420 | 115 | 3.20 / 135.63 | 2 | 20 |
9 | 8 | 0.12 | 165 | 15.19 | 301 | 754 | 3.96 / 136.38 | 2 | 30 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 19 | 15.17 | 432 | 125 | 0.12 / 128.64 | 2 | 3 |
2 | 3 | 1384.40 | -1 | 15.50 | 0 | 0 | 0.00 / 128.64 | 2 | 3 |
3 | 3 | 1423.72 | 1 | 15.11 | 2275 | 34 | 0.16 / 128.68 | 2 | 12 |
4 | 7 | 2002.96 | 38 | 14.86 | 2896 | 1635 | 1.79 / 130.31 | 2 | 13 |
5 | 13 | 1451.36 | 18 | 14.95 | 2233 | 601 | 2.40 / 130.91 | 2 | 17 |
6 | 13 | 884.32 | 18 | 15.06 | 1510 | 409 | 2.80 / 131.32 | 2 | 18 |
7 | 13 | 411.04 | 18 | 15.16 | 885 | 241 | 3.05 / 131.56 | 2 | 18 |
8 | 13 | 75.24 | 18 | 15.22 | 409 | 112 | 3.16 / 131.68 | 2 | 19 |
9 | 8 | 0.08 | 165 | 15.19 | 299 | 749 | 3.91 / 132.43 | 2 | 4 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 19 | 15.17 | 446 | 129 | 0.13 / 124.66 | 2 | 5 |
2 | 7 | 2011.20 | 38 | 14.88 | 2909 | 1645 | 1.77 / 126.30 | 2 | 13 |
3 | 13 | 1485.72 | 18 | 14.96 | 2283 | 615 | 2.39 / 126.92 | 2 | 17 |
4 | 13 | 1004.04 | 18 | 15.02 | 1663 | 450 | 2.84 / 127.37 | 2 | 20 |
5 | 13 | 449.84 | 18 | 15.15 | 944 | 257 | 3.10 / 127.63 | 2 | 17 |
6 | 13 | 109.36 | 18 | 15.21 | 466 | 128 | 3.22 / 127.75 | 2 | 20 |
7 | 8 | 0.28 | 165 | 15.18 | 305 | 764 | 3.99 / 128.52 | 2 | 21 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 19 | 15.17 | 432 | 125 | 0.12 / 120.65 | 2 | 3 |
2 | 7 | 2004.40 | 38 | 14.86 | 2906 | 1641 | 1.77 / 122.29 | 2 | 13 |
3 | 13 | 1520.72 | 18 | 14.95 | 2325 | 626 | 2.39 / 122.92 | 2 | 15 |
4 | 13 | 1017.44 | 18 | 15.03 | 1679 | 454 | 2.85 / 123.37 | 2 | 18 |
5 | 13 | 470.96 | 18 | 15.14 | 972 | 265 | 3.11 / 123.64 | 2 | 18 |
6 | 13 | 78.12 | 18 | 15.23 | 423 | 116 | 3.23 / 123.75 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.19 | 310 | 777 | 4.00 / 124.53 | 2 | 5 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 19 | 15.19 | 434 | 125 | 0.13 / 116.63 | 2 | 3 |
2 | 7 | 2005.32 | 39 | 14.88 | 2872 | 1667 | 1.79 / 118.30 | 2 | 13 |
3 | 13 | 1419.96 | 18 | 14.99 | 2160 | 583 | 2.37 / 118.88 | 2 | 16 |
4 | 13 | 942.76 | 18 | 15.05 | 1572 | 426 | 2.80 / 119.31 | 2 | 19 |
5 | 13 | 408.36 | 18 | 15.17 | 875 | 239 | 3.04 / 119.54 | 2 | 18 |
6 | 13 | 136.92 | 18 | 15.21 | 494 | 135 | 3.17 / 119.68 | 2 | 16 |
7 | 13 | 18.64 | 18 | 15.23 | 335 | 92 | 3.27 / 119.77 | 2 | 5 |
8 | 8 | -0.04 | 165 | 15.19 | 302 | 757 | 4.02 / 120.53 | 2 | 11 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 19 | 15.19 | 446 | 129 | 0.13 / 112.76 | 2 | 2 |
2 | 7 | 2002.48 | 38 | 14.87 | 2891 | 1634 | 1.76 / 114.39 | 2 | 12 |
3 | 13 | 1396.28 | 18 | 14.98 | 2163 | 583 | 2.35 / 114.97 | 2 | 16 |
4 | 13 | 963.44 | 18 | 15.05 | 1600 | 433 | 2.78 / 115.41 | 2 | 17 |
5 | 13 | 400.64 | 18 | 15.17 | 863 | 236 | 3.01 / 115.64 | 2 | 16 |
6 | 13 | 81.72 | 18 | 15.24 | 418 | 115 | 3.13 / 115.76 | 2 | 14 |
7 | 8 | 0.20 | 165 | 15.22 | 298 | 748 | 3.88 / 116.50 | 2 | 32 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 19 | 15.19 | 450 | 130 | 0.13 / 108.69 | 2 | 2 |
2 | 3 | 1386.44 | -1 | 15.52 | 0 | 0 | 0.00 / 108.69 | 2 | 2 |
3 | 3 | 1430.72 | 1 | 15.15 | 2278 | 35 | 0.16 / 108.73 | 2 | 11 |
4 | 7 | 2003.72 | 38 | 14.88 | 2897 | 1638 | 1.80 / 110.36 | 2 | 13 |
5 | 13 | 1556.40 | 18 | 14.95 | 2363 | 636 | 2.44 / 111.00 | 2 | 15 |
6 | 13 | 1050.00 | 18 | 15.02 | 1723 | 466 | 2.90 / 111.47 | 2 | 17 |
7 | 13 | 504.52 | 18 | 15.15 | 1006 | 274 | 3.18 / 111.74 | 2 | 18 |
8 | 13 | 103.64 | 18 | 15.23 | 451 | 124 | 3.30 / 111.86 | 2 | 15 |
9 | 8 | 0.16 | 165 | 15.21 | 304 | 763 | 4.07 / 112.63 | 2 | 9 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 19 | 15.19 | 431 | 124 | 0.12 / 104.78 | 2 | 3 |
2 | 3 | 1386.24 | -1 | 15.52 | 0 | 0 | 0.00 / 104.78 | 2 | 3 |
3 | 3 | 1430.80 | 1 | 15.14 | 2295 | 35 | 0.16 / 104.82 | 2 | 13 |
4 | 7 | 2009.96 | 38 | 14.88 | 2907 | 1644 | 1.80 / 106.46 | 2 | 15 |
5 | 13 | 1484.96 | 18 | 14.97 | 2267 | 611 | 2.41 / 107.07 | 2 | 16 |
6 | 13 | 899.88 | 18 | 15.08 | 1523 | 413 | 2.83 / 107.48 | 2 | 20 |
7 | 13 | 363.68 | 18 | 15.18 | 812 | 222 | 3.05 / 107.71 | 2 | 16 |
8 | 13 | 51.16 | 18 | 15.25 | 380 | 104 | 3.15 / 107.81 | 2 | 23 |
9 | 8 | 0.16 | 165 | 15.22 | 299 | 751 | 3.90 / 108.56 | 2 | 30 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 19 | 15.20 | 437 | 126 | 0.13 / 100.82 | 2 | 3 |
2 | 7 | 2004.44 | 38 | 14.89 | 2901 | 1641 | 1.77 / 102.46 | 2 | 13 |
3 | 13 | 1566.76 | 18 | 14.96 | 2376 | 640 | 2.41 / 103.10 | 2 | 15 |
4 | 13 | 1015.12 | 18 | 15.04 | 1678 | 454 | 2.86 / 103.56 | 2 | 17 |
5 | 13 | 366.48 | 18 | 15.19 | 817 | 223 | 3.09 / 103.78 | 2 | 17 |
6 | 13 | 96.52 | 18 | 15.24 | 440 | 121 | 3.21 / 103.90 | 2 | 15 |
7 | 8 | 0.08 | 165 | 15.21 | 302 | 758 | 3.96 / 104.66 | 2 | 24 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 19 | 15.20 | 461 | 133 | 0.13 / 96.86 | 2 | 3 |
2 | 7 | 2003.96 | 38 | 14.90 | 2903 | 1644 | 1.78 / 98.50 | 2 | 13 |
3 | 13 | 1520.36 | 18 | 14.98 | 2317 | 625 | 2.40 / 99.12 | 2 | 15 |
4 | 13 | 966.56 | 18 | 15.06 | 1623 | 440 | 2.84 / 99.56 | 2 | 18 |
5 | 13 | 363.40 | 18 | 15.20 | 819 | 224 | 3.07 / 99.79 | 2 | 17 |
6 | 13 | 90.96 | 18 | 15.24 | 443 | 122 | 3.19 / 99.91 | 2 | 7 |
7 | 8 | 0.20 | 165 | 15.22 | 312 | 784 | 3.97 / 100.69 | 2 | 25 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 19 | 15.21 | 459 | 133 | 0.13 / 92.91 | 2 | 5 |
2 | 7 | 2006.00 | 38 | 14.90 | 2904 | 1644 | 1.78 / 94.56 | 2 | 14 |
3 | 13 | 1397.08 | 18 | 15.00 | 2170 | 586 | 2.36 / 95.14 | 2 | 18 |
4 | 13 | 961.28 | 18 | 15.07 | 1616 | 438 | 2.80 / 95.58 | 2 | 18 |
5 | 13 | 452.12 | 18 | 15.18 | 946 | 258 | 3.06 / 95.84 | 2 | 17 |
6 | 13 | 43.72 | 18 | 15.26 | 378 | 104 | 3.16 / 95.94 | 2 | 15 |
7 | 8 | -0.08 | 165 | 15.22 | 311 | 781 | 3.94 / 96.72 | 2 | 25 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 19 | 15.21 | 456 | 132 | 0.13 / 88.87 | 2 | 3 |
2 | 7 | 2010.32 | 38 | 14.91 | 2915 | 1652 | 1.78 / 90.53 | 2 | 14 |
3 | 13 | 1569.56 | 18 | 14.97 | 2383 | 642 | 2.43 / 91.17 | 2 | 18 |
4 | 13 | 1029.36 | 18 | 15.06 | 1710 | 464 | 2.89 / 91.63 | 2 | 18 |
5 | 13 | 476.64 | 18 | 15.18 | 969 | 265 | 3.15 / 91.90 | 2 | 17 |
6 | 13 | 76.16 | 18 | 15.25 | 420 | 115 | 3.27 / 92.01 | 2 | 11 |
7 | 8 | 0.04 | 165 | 15.23 | 305 | 766 | 4.04 / 92.78 | 2 | 7 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.56 | 19 | 15.21 | 459 | 133 | 0.13 / 84.91 | 2 | 4 |
2 | 3 | 1383.40 | -1 | 15.53 | 0 | 0 | 0.00 / 84.91 | 2 | 4 |
3 | 3 | 1425.56 | 1 | 15.16 | 2278 | 35 | 0.17 / 84.94 | 2 | 14 |
4 | 7 | 2008.96 | 38 | 14.92 | 2880 | 1633 | 1.80 / 86.58 | 2 | 14 |
5 | 13 | 1477.24 | 18 | 15.00 | 2240 | 605 | 2.40 / 87.18 | 2 | 15 |
6 | 13 | 990.56 | 18 | 15.07 | 1639 | 445 | 2.85 / 87.63 | 2 | 18 |
7 | 13 | 394.20 | 18 | 15.20 | 865 | 237 | 3.09 / 87.86 | 2 | 17 |
8 | 13 | 113.20 | 18 | 15.25 | 455 | 125 | 3.21 / 87.99 | 2 | 14 |
9 | 8 | -0.04 | 165 | 15.23 | 301 | 756 | 3.97 / 88.74 | 2 | 25 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.88 | 19 | 15.21 | 472 | 136 | 0.14 / 80.85 | 2 | 4 |
2 | 7 | 2004.00 | 39 | 14.90 | 2906 | 1689 | 1.83 / 82.53 | 2 | 12 |
3 | 13 | 1572.04 | 18 | 14.98 | 2382 | 642 | 2.47 / 83.18 | 2 | 16 |
4 | 13 | 1020.40 | 18 | 15.06 | 1681 | 456 | 2.92 / 83.63 | 2 | 17 |
5 | 13 | 419.80 | 18 | 15.20 | 886 | 242 | 3.17 / 83.88 | 2 | 17 |
6 | 13 | 143.08 | 18 | 15.24 | 505 | 139 | 3.30 / 84.01 | 2 | 13 |
7 | 8 | 0.24 | 165 | 15.24 | 303 | 762 | 4.07 / 84.78 | 2 | 27 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 19 | 15.22 | 450 | 130 | 0.13 / 76.95 | 2 | 4 |
2 | 7 | 1974.28 | 38 | 14.93 | 2865 | 1625 | 1.76 / 78.57 | 2 | 14 |
3 | 13 | 1425.92 | 18 | 15.00 | 2206 | 596 | 2.35 / 79.17 | 2 | 15 |
4 | 13 | 927.08 | 18 | 15.09 | 1575 | 428 | 2.78 / 79.60 | 2 | 16 |
5 | 13 | 364.92 | 18 | 15.22 | 824 | 226 | 3.00 / 79.82 | 2 | 16 |
6 | 13 | 41.96 | 18 | 15.27 | 380 | 104 | 3.11 / 79.93 | 2 | 19 |
7 | 8 | 0.12 | 165 | 15.23 | 312 | 784 | 3.89 / 80.71 | 2 | 9 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 19 | 15.24 | 452 | 131 | 0.13 / 73.14 | 2 | 4 |
2 | 7 | 1992.08 | 38 | 14.92 | 2884 | 1635 | 1.77 / 74.78 | 2 | 13 |
3 | 13 | 1392.60 | 18 | 15.01 | 2157 | 583 | 2.35 / 75.36 | 2 | 17 |
4 | 13 | 858.72 | 18 | 15.11 | 1475 | 401 | 2.75 / 75.76 | 2 | 17 |
5 | 13 | 309.68 | 18 | 15.23 | 734 | 201 | 2.95 / 75.96 | 2 | 17 |
6 | 13 | 49.32 | 18 | 15.26 | 368 | 101 | 3.05 / 76.07 | 2 | 15 |
7 | 8 | 0.08 | 165 | 15.23 | 299 | 751 | 3.80 / 76.82 | 2 | 6 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 19 | 15.23 | 427 | 124 | 0.12 / 69.73 | 2 | 5 |
2 | 3 | 1377.56 | -1 | 15.52 | 0 | 0 | 0.00 / 69.73 | 2 | 5 |
3 | 3 | 1427.36 | 1 | 15.17 | 2274 | 34 | 0.16 / 69.77 | 2 | 12 |
4 | 7 | 1761.92 | 38 | 15.01 | 2588 | 1476 | 1.63 / 71.25 | 2 | 13 |
5 | 13 | 1190.96 | 18 | 15.10 | 1895 | 515 | 2.15 / 71.76 | 2 | 17 |
6 | 13 | 634.52 | 18 | 15.19 | 1192 | 326 | 2.48 / 72.09 | 2 | 18 |
7 | 13 | 228.96 | 18 | 15.26 | 631 | 173 | 2.65 / 72.26 | 2 | 16 |
8 | 8 | -0.04 | 165 | 15.27 | 299 | 753 | 3.40 / 73.01 | 2 | 30 |
Average= | 3.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 19 | 15.22 | 441 | 128 | 0.13 / 65.88 | 2 | 4 |
2 | 7 | 2007.80 | 38 | 14.91 | 2898 | 1642 | 1.77 / 67.52 | 2 | 12 |
3 | 13 | 1421.48 | 18 | 15.02 | 2179 | 589 | 2.36 / 68.11 | 2 | 16 |
4 | 13 | 902.36 | 18 | 15.10 | 1525 | 414 | 2.77 / 68.53 | 2 | 18 |
5 | 13 | 412.20 | 18 | 15.20 | 882 | 241 | 3.01 / 68.77 | 2 | 17 |
6 | 13 | 38.44 | 18 | 15.28 | 354 | 97 | 3.11 / 68.87 | 2 | 11 |
7 | 8 | 0.04 | 165 | 15.25 | 296 | 745 | 3.86 / 69.61 | 2 | 26 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 19 | 15.23 | 449 | 130 | 0.13 / 61.98 | 2 | 3 |
2 | 7 | 2004.56 | 38 | 14.93 | 2903 | 1647 | 1.78 / 63.62 | 2 | 11 |
3 | 13 | 1416.28 | 18 | 15.02 | 2189 | 592 | 2.37 / 64.21 | 2 | 15 |
4 | 13 | 988.84 | 18 | 15.08 | 1638 | 445 | 2.81 / 64.66 | 2 | 17 |
5 | 13 | 430.36 | 18 | 15.20 | 903 | 247 | 3.06 / 64.91 | 2 | 17 |
6 | 13 | 42.44 | 18 | 15.27 | 361 | 99 | 3.16 / 65.01 | 2 | 15 |
7 | 8 | 0.28 | 165 | 15.24 | 298 | 749 | 3.91 / 65.75 | 2 | 19 |
Average= | 3.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 19 | 15.23 | 452 | 131 | 0.13 / 58.04 | 2 | 4 |
2 | 7 | 2004.00 | 38 | 14.93 | 2899 | 1645 | 1.78 / 59.68 | 2 | 15 |
3 | 13 | 1500.08 | 18 | 15.01 | 2293 | 620 | 2.40 / 60.30 | 2 | 15 |
4 | 13 | 1000.56 | 18 | 15.08 | 1658 | 450 | 2.85 / 60.75 | 2 | 18 |
5 | 13 | 391.92 | 18 | 15.21 | 849 | 232 | 3.08 / 60.99 | 2 | 17 |
6 | 13 | 57.96 | 18 | 15.27 | 384 | 106 | 3.18 / 61.09 | 2 | 13 |
7 | 8 | -0.04 | 165 | 15.25 | 300 | 755 | 3.94 / 61.85 | 2 | 23 |
Average= | 3.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 19 | 15.24 | 453 | 131 | 0.13 / 54.15 | 2 | 3 |
2 | 7 | 2006.60 | 38 | 14.93 | 2893 | 1641 | 1.77 / 55.79 | 2 | 12 |
3 | 13 | 1406.96 | 18 | 15.03 | 2172 | 588 | 2.36 / 56.38 | 2 | 16 |
4 | 13 | 928.20 | 18 | 15.10 | 1558 | 423 | 2.78 / 56.80 | 2 | 18 |
5 | 13 | 433.24 | 18 | 15.21 | 912 | 250 | 3.03 / 57.05 | 2 | 18 |
6 | 13 | 34.96 | 18 | 15.28 | 359 | 99 | 3.13 / 57.15 | 2 | 15 |
7 | 8 | 0.16 | 165 | 15.25 | 302 | 760 | 3.89 / 57.91 | 2 | 18 |
Average= | 3.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 19 | 15.23 | 449 | 130 | 0.13 / 50.18 | 2 | 4 |
2 | 3 | 1371.80 | -1 | 15.54 | 0 | 0 | 0.00 / 50.18 | 2 | 4 |
3 | 7 | 2004.68 | 39 | 14.94 | 2896 | 1687 | 1.82 / 51.87 | 2 | 14 |
4 | 13 | 1560.80 | 18 | 15.01 | 2376 | 642 | 2.46 / 52.51 | 2 | 15 |
5 | 13 | 992.64 | 18 | 15.10 | 1648 | 448 | 2.91 / 52.95 | 2 | 18 |
6 | 13 | 333.32 | 18 | 15.24 | 773 | 212 | 3.12 / 53.17 | 2 | 17 |
7 | 13 | 24.28 | 18 | 15.30 | 339 | 93 | 3.21 / 53.26 | 2 | 15 |
8 | 8 | 0.08 | 165 | 15.26 | 300 | 755 | 3.97 / 54.02 | 2 | 24 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 21 | 15.23 | 443 | 142 | 0.14 / 46.41 | 2 | 4 |
2 | 3 | 1315.88 | -3 | 15.54 | 0 | 0 | 0.00 / 46.41 | 2 | 4 |
3 | 7 | 2007.84 | 38 | 14.94 | 2884 | 1637 | 1.78 / 48.04 | 2 | 12 |
4 | 13 | 1409.16 | 18 | 15.04 | 2169 | 587 | 2.37 / 48.63 | 2 | 16 |
5 | 13 | 934.76 | 18 | 15.10 | 1567 | 426 | 2.79 / 49.06 | 2 | 17 |
6 | 13 | 393.52 | 18 | 15.22 | 856 | 235 | 3.03 / 49.29 | 2 | 17 |
7 | 8 | 0.12 | 165 | 15.26 | 300 | 755 | 3.78 / 50.05 | 2 | 15 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 30 | 15.27 | 440 | 202 | 0.20 / 42.63 | 2 | 4 |
2 | 3 | 1010.96 | -15 | 15.56 | 0 | 0 | 0.00 / 42.63 | 2 | 4 |
3 | 7 | 2005.72 | 38 | 14.94 | 2892 | 1642 | 1.84 / 44.27 | 2 | 13 |
4 | 13 | 1452.36 | 18 | 15.03 | 2217 | 600 | 2.44 / 44.87 | 2 | 15 |
5 | 13 | 967.84 | 18 | 15.09 | 1606 | 436 | 2.88 / 45.31 | 2 | 18 |
6 | 13 | 328.44 | 18 | 15.24 | 758 | 208 | 3.09 / 45.52 | 2 | 16 |
7 | 8 | 0.00 | 165 | 15.26 | 298 | 750 | 3.84 / 46.27 | 2 | 23 |
Average= | 3.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 30 | 15.26 | 435 | 199 | 0.20 / 39.92 | 2 | 5 |
2 | 7 | 1419.68 | 38 | 15.14 | 2155 | 1240 | 1.44 / 41.15 | 2 | 15 |
3 | 13 | 792.68 | 18 | 15.24 | 1374 | 377 | 1.82 / 41.53 | 2 | 18 |
4 | 13 | 193.84 | 18 | 15.34 | 573 | 158 | 1.97 / 41.69 | 2 | 14 |
5 | 8 | 0.12 | 165 | 15.32 | 292 | 738 | 2.71 / 42.43 | 2 | 20 |
Average= | 3.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 29 | 15.25 | 415 | 184 | 0.18 / 36.62 | 2 | 4 |
2 | 7 | 1701.56 | 38 | 15.05 | 2504 | 1432 | 1.62 / 38.06 | 2 | 13 |
3 | 13 | 1094.08 | 18 | 15.15 | 1761 | 480 | 2.10 / 38.54 | 2 | 17 |
4 | 13 | 644.60 | 18 | 15.21 | 1190 | 326 | 2.42 / 38.86 | 2 | 18 |
5 | 13 | 81.72 | 18 | 15.31 | 405 | 112 | 2.53 / 38.97 | 2 | 14 |
6 | 8 | 0.08 | 165 | 15.29 | 294 | 742 | 3.27 / 39.72 | 2 | 17 |
Average= | 3.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 29 | 15.28 | 413 | 183 | 0.18 / 32.57 | 2 | 4 |
2 | 7 | 1848.88 | 74 | 14.90 | 2667 | 2941 | 3.12 / 35.51 | 2 | 13 |
3 | 13 | 319.88 | 18 | 15.26 | 714 | 196 | 3.32 / 35.70 | 2 | 16 |
4 | 13 | 23.96 | 18 | 15.31 | 299 | 82 | 3.40 / 35.79 | 2 | 11 |
5 | 8 | 0.04 | 165 | 15.28 | 260 | 656 | 4.06 / 36.44 | 2 | 20 |
Average= | 3.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 29 | 15.28 | 392 | 174 | 0.17 / 28.87 | 2 | 4 |
2 | 7 | 1658.08 | 74 | 14.97 | 2428 | 2690 | 2.86 / 31.56 | 2 | 14 |
3 | 13 | 231.48 | 18 | 15.31 | 589 | 162 | 3.03 / 31.72 | 2 | 15 |
4 | 8 | 0.20 | 165 | 15.31 | 263 | 664 | 3.69 / 32.38 | 2 | 20 |
Average= | 2.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 29 | 15.31 | 421 | 187 | 0.19 / 25.23 | 2 | 4 |
2 | 3 | 1018.20 | 1 | 15.34 | 1702 | 26 | 0.21 / 25.25 | 2 | 11 |
3 | 7 | 1613.04 | 74 | 14.99 | 2367 | 2626 | 2.84 / 27.88 | 2 | 14 |
4 | 13 | 163.60 | 18 | 15.33 | 502 | 139 | 2.98 / 28.02 | 2 | 15 |
5 | 8 | 0.20 | 165 | 15.32 | 267 | 675 | 3.65 / 28.69 | 2 | 23 |
Average= | 2.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 30 | 15.32 | 415 | 191 | 0.19 / 22.13 | 2 | 4 |
2 | 3 | 969.92 | -1 | 15.60 | 0 | 0 | 0.00 / 22.13 | 2 | 4 |
3 | 7 | 1314.64 | 74 | 15.12 | 1991 | 2228 | 2.42 / 24.36 | 2 | 15 |
4 | 8 | 0.04 | 165 | 15.36 | 268 | 679 | 3.10 / 25.04 | 2 | 17 |
Average= | 2.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 29 | 15.31 | 418 | 186 | 0.19 / 19.32 | 2 | 4 |
2 | 7 | 1111.48 | 74 | 15.18 | 1727 | 1940 | 2.13 / 21.26 | 2 | 15 |
3 | 8 | 0.00 | 165 | 15.37 | 269 | 682 | 2.81 / 21.94 | 2 | 17 |
Average= | 2.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 29 | 15.32 | 419 | 186 | 0.19 / 16.48 | 2 | 4 |
2 | 7 | 1117.68 | 75 | 15.17 | 1738 | 1977 | 2.16 / 18.45 | 2 | 15 |
3 | 8 | 0.12 | 165 | 15.35 | 269 | 681 | 2.84 / 19.14 | 2 | 20 |
Average= | 2.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 29 | 15.31 | 399 | 177 | 0.18 / 13.63 | 2 | 4 |
2 | 7 | 1144.88 | 74 | 15.17 | 1767 | 1984 | 2.16 / 15.61 | 2 | 15 |
3 | 8 | 0.00 | 165 | 15.35 | 267 | 676 | 2.84 / 16.29 | 2 | 15 |
Average= | 2.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 29 | 15.26 | 409 | 181 | 0.18 / 10.82 | 2 | 4 |
2 | 3 | 1019.68 | 1 | 15.31 | 1696 | 26 | 0.21 / 10.84 | 2 | 12 |
3 | 7 | 1109.04 | 74 | 15.17 | 1722 | 1933 | 2.14 / 12.78 | 2 | 15 |
4 | 8 | 0.04 | 165 | 15.35 | 267 | 676 | 2.82 / 13.45 | 2 | 18 |
Average= | 2.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 29 | 15.32 | 411 | 183 | 0.18 / 7.19 | 2 | 4 |
2 | 7 | 1523.24 | 74 | 15.01 | 2250 | 2499 | 2.68 / 9.69 | 2 | 13 |
3 | 13 | 312.96 | 18 | 15.27 | 701 | 193 | 2.87 / 9.89 | 2 | 15 |
4 | 13 | 42.92 | 18 | 15.32 | 326 | 90 | 2.96 / 9.98 | 2 | 12 |
5 | 8 | 0.12 | 165 | 15.29 | 262 | 661 | 3.63 / 10.64 | 2 | 15 |
Average= | 2.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 33 | 15.28 | 412 | 208 | 0.21 / 4.45 | 2 | 4 |
2 | 3 | 872.12 | -2 | 15.60 | 0 | 0 | 0.00 / 4.45 | 2 | 4 |
3 | 3 | 949.80 | -1 | 15.62 | 0 | 0 | 0.00 / 4.45 | 2 | 4 |
4 | 7 | 1071.12 | 74 | 15.19 | 1671 | 1878 | 2.09 / 6.33 | 2 | 15 |
5 | 8 | 0.08 | 165 | 15.36 | 268 | 679 | 2.77 / 7.01 | 2 | 14 |
Average= | 2.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 28 | 15.46 | 383 | 166 | 0.17 / 1.77 | 2 | 3 |
2 | 3 | 1021.16 | 1 | 15.35 | 1706 | 26 | 0.19 / 1.79 | 2 | 10 |
3 | 7 | 1006.48 | 74 | 15.17 | 1583 | 1777 | 1.97 / 3.57 | 2 | 15 |
4 | 8 | 0.00 | 165 | 15.33 | 267 | 675 | 2.64 / 4.25 | 2 | 13 |
Average= | 2.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 169.20 | 27 | 15.59 | 466 | 196 | 0.20 / 0.20 | 2 | 3 |
2 | 7 | 184.64 | 74 | 15.55 | 475 | 547 | 0.74 / 0.74 | 2 | 4 |
3 | 8 | 0.20 | 240 | 15.51 | 231 | 860 | 1.60 / 1.60 | 2 | 15 |
Average= | 1.60 (KJ/cycle) |