SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 29 | 15.13 | 527 | 231 | 0.23 / 306.12 | 2 | 3 |
2 | 7 | 2004.64 | 38 | 14.87 | 2898 | 1638 | 1.87 / 307.76 | 2 | 2 |
3 | 13 | 1314.04 | 18 | 14.97 | 2083 | 561 | 2.43 / 308.32 | 2 | 3 |
4 | 13 | 549.12 | 18 | 15.11 | 1135 | 309 | 2.74 / 308.63 | 2 | 4 |
5 | 13 | 101.12 | 7 | 15.24 | 537 | 57 | 2.80 / 308.69 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.21 | 371 | 931 | 3.73 / 309.62 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 29 | 15.14 | 543 | 238 | 0.24 / 302.35 | 2 | 3 |
2 | 7 | 2005.28 | 38 | 14.90 | 2899 | 1641 | 1.88 / 303.99 | 2 | 3 |
3 | 13 | 1302.68 | 18 | 14.98 | 2056 | 554 | 2.43 / 304.55 | 2 | 3 |
4 | 13 | 651.44 | 18 | 15.10 | 1244 | 338 | 2.77 / 304.88 | 2 | 3 |
5 | 13 | 125.88 | 7 | 15.24 | 559 | 60 | 2.83 / 304.94 | 2 | 4 |
6 | 13 | 47.48 | 5 | 15.26 | 456 | 35 | 2.87 / 304.98 | 2 | 4 |
7 | 8 | -0.16 | 165 | 15.21 | 364 | 914 | 3.78 / 305.89 | 2 | 5 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 29 | 15.15 | 521 | 229 | 0.23 / 298.59 | 2 | 3 |
2 | 7 | 2002.68 | 38 | 14.88 | 2897 | 1638 | 1.87 / 300.23 | 2 | 3 |
3 | 13 | 1293.72 | 18 | 14.99 | 2054 | 554 | 2.42 / 300.78 | 2 | 3 |
4 | 13 | 653.12 | 18 | 15.10 | 1259 | 342 | 2.76 / 301.13 | 2 | 3 |
5 | 13 | 143.48 | 8 | 15.23 | 597 | 73 | 2.84 / 301.20 | 2 | 4 |
6 | 8 | 0.40 | 165 | 15.21 | 364 | 914 | 3.75 / 302.11 | 2 | 5 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 29 | 15.14 | 522 | 229 | 0.23 / 294.84 | 2 | 3 |
2 | 7 | 2011.68 | 38 | 14.90 | 2901 | 1643 | 1.87 / 296.48 | 2 | 2 |
3 | 13 | 1207.76 | 18 | 15.01 | 1953 | 528 | 2.40 / 297.01 | 2 | 3 |
4 | 13 | 710.40 | 18 | 15.09 | 1334 | 362 | 2.76 / 297.37 | 2 | 3 |
5 | 13 | 182.24 | 9 | 15.22 | 630 | 86 | 2.85 / 297.46 | 2 | 4 |
6 | 8 | -0.04 | 165 | 15.21 | 360 | 903 | 3.75 / 298.36 | 2 | 8 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 29 | 15.14 | 524 | 230 | 0.23 / 291.11 | 2 | 3 |
2 | 7 | 2004.24 | 38 | 14.90 | 2895 | 1639 | 1.87 / 292.75 | 2 | 2 |
3 | 13 | 1188.40 | 18 | 15.01 | 1935 | 523 | 2.39 / 293.27 | 2 | 3 |
4 | 13 | 693.32 | 18 | 15.09 | 1293 | 351 | 2.74 / 293.63 | 2 | 3 |
5 | 13 | 182.64 | 9 | 15.23 | 633 | 87 | 2.83 / 293.71 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.21 | 358 | 898 | 3.73 / 294.61 | 2 | 4 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 29 | 15.14 | 536 | 235 | 0.24 / 287.28 | 2 | 3 |
2 | 7 | 2012.60 | 38 | 14.91 | 2906 | 1646 | 1.88 / 288.93 | 2 | 2 |
3 | 13 | 1327.24 | 18 | 14.99 | 2095 | 565 | 2.45 / 289.49 | 2 | 3 |
4 | 13 | 670.92 | 18 | 15.11 | 1276 | 347 | 2.79 / 289.84 | 2 | 3 |
5 | 13 | 167.68 | 8 | 15.24 | 625 | 76 | 2.87 / 289.92 | 2 | 4 |
6 | 13 | 61.84 | 6 | 15.27 | 481 | 44 | 2.91 / 289.96 | 2 | 4 |
7 | 8 | 0.80 | 165 | 15.23 | 367 | 922 | 3.84 / 290.88 | 2 | 7 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 29 | 15.16 | 513 | 226 | 0.23 / 283.47 | 2 | 3 |
2 | 7 | 2012.40 | 38 | 14.90 | 2903 | 1644 | 1.87 / 285.11 | 2 | 2 |
3 | 13 | 1441.40 | 18 | 14.96 | 2242 | 604 | 2.47 / 285.71 | 2 | 3 |
4 | 13 | 757.16 | 18 | 15.08 | 1383 | 375 | 2.85 / 286.09 | 2 | 3 |
5 | 13 | 127.12 | 7 | 15.23 | 553 | 59 | 2.91 / 286.15 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.22 | 357 | 897 | 3.80 / 287.05 | 2 | 11 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 29 | 15.15 | 533 | 234 | 0.23 / 279.68 | 2 | 3 |
2 | 7 | 2006.24 | 38 | 14.91 | 2894 | 1640 | 1.87 / 281.32 | 2 | 2 |
3 | 13 | 1291.28 | 18 | 14.99 | 2058 | 555 | 2.43 / 281.88 | 2 | 3 |
4 | 13 | 752.96 | 18 | 15.09 | 1376 | 374 | 2.80 / 282.25 | 2 | 3 |
5 | 13 | 219.20 | 10 | 15.22 | 688 | 105 | 2.91 / 282.35 | 2 | 4 |
6 | 8 | 0.56 | 165 | 15.22 | 353 | 886 | 3.79 / 283.24 | 2 | 13 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 29 | 15.15 | 535 | 235 | 0.24 / 275.93 | 2 | 3 |
2 | 7 | 2005.60 | 38 | 14.90 | 2897 | 1640 | 1.88 / 277.57 | 2 | 2 |
3 | 13 | 1214.48 | 18 | 15.01 | 1953 | 528 | 2.40 / 278.10 | 2 | 3 |
4 | 13 | 691.80 | 18 | 15.10 | 1298 | 353 | 2.76 / 278.45 | 2 | 3 |
5 | 13 | 170.44 | 9 | 15.24 | 624 | 86 | 2.84 / 278.54 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.23 | 361 | 907 | 3.75 / 279.45 | 2 | 6 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 29 | 15.14 | 510 | 224 | 0.22 / 272.09 | 2 | 3 |
2 | 7 | 2003.44 | 38 | 14.91 | 2896 | 1641 | 1.86 / 273.73 | 2 | 2 |
3 | 13 | 1317.48 | 18 | 14.99 | 2083 | 562 | 2.43 / 274.29 | 2 | 3 |
4 | 13 | 769.48 | 18 | 15.09 | 1401 | 381 | 2.81 / 274.67 | 2 | 3 |
5 | 13 | 138.24 | 8 | 15.24 | 582 | 71 | 2.88 / 274.74 | 2 | 4 |
6 | 13 | 59.16 | 5 | 15.27 | 465 | 36 | 2.91 / 274.78 | 2 | 4 |
7 | 8 | 0.24 | 165 | 15.22 | 367 | 922 | 3.84 / 275.70 | 2 | 8 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 29 | 15.17 | 541 | 238 | 0.24 / 268.32 | 2 | 3 |
2 | 7 | 2006.12 | 38 | 14.90 | 2914 | 1650 | 1.89 / 269.97 | 2 | 2 |
3 | 13 | 1211.60 | 18 | 15.01 | 1964 | 531 | 2.42 / 270.50 | 2 | 3 |
4 | 13 | 702.08 | 18 | 15.11 | 1330 | 362 | 2.78 / 270.86 | 2 | 3 |
5 | 13 | 182.56 | 9 | 15.24 | 633 | 87 | 2.87 / 270.95 | 2 | 4 |
6 | 8 | 0.40 | 165 | 15.23 | 363 | 912 | 3.78 / 271.86 | 2 | 8 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 29 | 15.15 | 527 | 232 | 0.23 / 264.52 | 2 | 3 |
2 | 7 | 2004.12 | 38 | 14.92 | 2901 | 1645 | 1.88 / 266.16 | 2 | 2 |
3 | 13 | 1318.76 | 18 | 15.01 | 2089 | 564 | 2.44 / 266.73 | 2 | 3 |
4 | 13 | 687.04 | 18 | 15.13 | 1301 | 354 | 2.80 / 267.08 | 2 | 3 |
5 | 13 | 177.20 | 9 | 15.25 | 636 | 87 | 2.88 / 267.17 | 2 | 4 |
6 | 8 | 0.12 | 165 | 15.25 | 364 | 916 | 3.80 / 268.08 | 2 | 7 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 28 | 15.17 | 535 | 227 | 0.23 / 260.82 | 2 | 3 |
2 | 7 | 2003.80 | 38 | 14.90 | 2905 | 1645 | 1.87 / 262.46 | 2 | 2 |
3 | 13 | 1211.36 | 18 | 15.02 | 1965 | 531 | 2.40 / 262.99 | 2 | 3 |
4 | 13 | 594.40 | 18 | 15.13 | 1187 | 323 | 2.73 / 263.31 | 2 | 4 |
5 | 13 | 116.12 | 7 | 15.27 | 547 | 58 | 2.79 / 263.37 | 2 | 4 |
6 | 8 | 0.52 | 165 | 15.24 | 363 | 913 | 3.70 / 264.29 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 28 | 15.16 | 540 | 229 | 0.23 / 257.04 | 2 | 3 |
2 | 7 | 2004.96 | 38 | 14.90 | 2904 | 1644 | 1.87 / 258.69 | 2 | 2 |
3 | 13 | 1196.48 | 18 | 15.02 | 1943 | 525 | 2.40 / 259.21 | 2 | 3 |
4 | 13 | 665.20 | 18 | 15.11 | 1266 | 344 | 2.74 / 259.56 | 2 | 3 |
5 | 13 | 147.48 | 8 | 15.23 | 600 | 73 | 2.82 / 259.63 | 2 | 4 |
6 | 13 | 50.88 | 5 | 15.27 | 461 | 35 | 2.85 / 259.67 | 2 | 4 |
7 | 8 | 0.24 | 165 | 15.24 | 367 | 923 | 3.77 / 260.59 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 28 | 15.17 | 527 | 224 | 0.22 / 253.25 | 2 | 3 |
2 | 7 | 2009.44 | 38 | 14.90 | 2937 | 1663 | 1.89 / 254.91 | 2 | 3 |
3 | 13 | 1192.48 | 18 | 15.01 | 1941 | 524 | 2.41 / 255.43 | 2 | 3 |
4 | 13 | 562.24 | 18 | 15.13 | 1163 | 317 | 2.73 / 255.75 | 2 | 4 |
5 | 13 | 174.28 | 9 | 15.24 | 632 | 87 | 2.81 / 255.84 | 2 | 4 |
6 | 13 | 64.08 | 6 | 15.27 | 476 | 44 | 2.86 / 255.88 | 2 | 4 |
7 | 8 | -0.40 | 165 | 15.24 | 371 | 933 | 3.79 / 256.81 | 2 | 6 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 28 | 15.16 | 517 | 219 | 0.22 / 249.52 | 2 | 3 |
2 | 7 | 2003.40 | 38 | 14.89 | 2904 | 1643 | 1.86 / 251.17 | 2 | 3 |
3 | 13 | 1277.96 | 18 | 15.01 | 2042 | 552 | 2.41 / 251.72 | 2 | 3 |
4 | 13 | 620.36 | 18 | 15.13 | 1220 | 332 | 2.75 / 252.05 | 2 | 4 |
5 | 13 | 115.36 | 7 | 15.28 | 543 | 58 | 2.80 / 252.11 | 2 | 4 |
6 | 8 | -0.08 | 165 | 15.25 | 363 | 913 | 3.72 / 253.02 | 2 | 6 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 28 | 15.17 | 530 | 225 | 0.23 / 245.76 | 2 | 3 |
2 | 7 | 2003.68 | 38 | 14.89 | 2912 | 1648 | 1.87 / 247.41 | 2 | 3 |
3 | 13 | 1190.36 | 18 | 15.01 | 1938 | 524 | 2.40 / 247.93 | 2 | 3 |
4 | 13 | 580.56 | 18 | 15.14 | 1171 | 319 | 2.72 / 248.25 | 2 | 4 |
5 | 13 | 105.12 | 7 | 15.27 | 545 | 58 | 2.77 / 248.31 | 2 | 4 |
6 | 13 | 53.80 | 5 | 15.29 | 468 | 36 | 2.81 / 248.34 | 2 | 4 |
7 | 13 | 47.72 | 5 | 15.29 | 463 | 35 | 2.84 / 248.38 | 2 | 4 |
8 | 8 | 0.20 | 165 | 15.23 | 369 | 927 | 3.77 / 249.30 | 2 | 9 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 28 | 15.17 | 548 | 233 | 0.23 / 241.98 | 2 | 3 |
2 | 7 | 2007.16 | 38 | 14.89 | 2923 | 1654 | 1.89 / 243.63 | 2 | 3 |
3 | 13 | 1219.04 | 18 | 15.02 | 1982 | 536 | 2.42 / 244.17 | 2 | 3 |
4 | 13 | 695.40 | 18 | 15.11 | 1328 | 361 | 2.78 / 244.53 | 2 | 4 |
5 | 13 | 154.12 | 8 | 15.25 | 615 | 75 | 2.86 / 244.61 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.24 | 368 | 925 | 3.78 / 245.53 | 2 | 5 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 28 | 15.16 | 540 | 229 | 0.23 / 238.23 | 2 | 3 |
2 | 7 | 2004.12 | 39 | 14.90 | 2911 | 1692 | 1.92 / 239.92 | 2 | 3 |
3 | 13 | 1194.00 | 18 | 15.03 | 1955 | 529 | 2.45 / 240.45 | 2 | 3 |
4 | 13 | 568.84 | 18 | 15.14 | 1163 | 317 | 2.77 / 240.76 | 2 | 4 |
5 | 13 | 102.36 | 7 | 15.26 | 550 | 59 | 2.83 / 240.82 | 2 | 4 |
6 | 8 | -0.04 | 165 | 15.25 | 368 | 926 | 3.75 / 241.75 | 2 | 7 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 28 | 15.18 | 551 | 234 | 0.23 / 234.51 | 2 | 3 |
2 | 7 | 2006.36 | 38 | 14.91 | 2909 | 1648 | 1.88 / 236.15 | 2 | 3 |
3 | 13 | 1203.44 | 18 | 15.04 | 1964 | 532 | 2.41 / 236.68 | 2 | 3 |
4 | 13 | 570.36 | 18 | 15.15 | 1168 | 319 | 2.73 / 237.00 | 2 | 4 |
5 | 13 | 101.52 | 7 | 15.27 | 542 | 58 | 2.79 / 237.06 | 2 | 4 |
6 | 8 | -0.20 | 165 | 15.24 | 372 | 935 | 3.73 / 238.00 | 2 | 8 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 28 | 15.17 | 543 | 231 | 0.23 / 230.69 | 2 | 3 |
2 | 7 | 2004.56 | 38 | 14.91 | 2915 | 1652 | 1.88 / 232.35 | 2 | 3 |
3 | 13 | 1300.60 | 18 | 15.01 | 2088 | 564 | 2.45 / 232.91 | 2 | 3 |
4 | 13 | 641.08 | 18 | 15.13 | 1255 | 342 | 2.79 / 233.25 | 2 | 4 |
5 | 13 | 135.00 | 8 | 15.27 | 596 | 73 | 2.86 / 233.32 | 2 | 4 |
6 | 8 | 0.68 | 165 | 15.25 | 376 | 946 | 3.81 / 234.27 | 2 | 5 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 28 | 15.18 | 557 | 237 | 0.24 / 226.87 | 2 | 3 |
2 | 7 | 2010.00 | 38 | 14.89 | 2916 | 1650 | 1.89 / 228.52 | 2 | 3 |
3 | 13 | 1184.20 | 18 | 15.03 | 1949 | 527 | 2.41 / 229.05 | 2 | 3 |
4 | 13 | 564.44 | 18 | 15.15 | 1161 | 317 | 2.73 / 229.37 | 2 | 4 |
5 | 13 | 111.16 | 7 | 15.28 | 544 | 58 | 2.79 / 229.43 | 2 | 4 |
6 | 13 | 16.80 | 18 | 15.29 | 420 | 116 | 2.90 / 229.54 | 2 | 3 |
7 | 8 | 0.28 | 165 | 15.24 | 367 | 923 | 3.83 / 230.46 | 2 | 8 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 28 | 15.15 | 525 | 223 | 0.22 / 223.05 | 2 | 3 |
2 | 7 | 2009.00 | 38 | 14.90 | 2930 | 1659 | 1.88 / 224.71 | 2 | 3 |
3 | 13 | 1311.24 | 18 | 15.02 | 2095 | 566 | 2.45 / 225.28 | 2 | 3 |
4 | 13 | 649.60 | 18 | 15.13 | 1277 | 348 | 2.80 / 225.63 | 2 | 4 |
5 | 13 | 135.36 | 8 | 15.28 | 605 | 74 | 2.87 / 225.70 | 2 | 4 |
6 | 8 | 0.28 | 165 | 15.25 | 372 | 936 | 3.81 / 226.64 | 2 | 5 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 28 | 15.18 | 559 | 238 | 0.24 / 219.25 | 2 | 3 |
2 | 7 | 2009.04 | 38 | 14.90 | 2919 | 1653 | 1.89 / 220.90 | 2 | 3 |
3 | 13 | 1197.32 | 18 | 15.04 | 1945 | 527 | 2.42 / 221.43 | 2 | 3 |
4 | 13 | 676.68 | 18 | 15.12 | 1312 | 357 | 2.77 / 221.79 | 2 | 4 |
5 | 13 | 97.28 | 7 | 15.30 | 560 | 60 | 2.83 / 221.85 | 2 | 4 |
6 | 13 | 52.48 | 5 | 15.30 | 485 | 37 | 2.87 / 221.88 | 2 | 4 |
7 | 8 | 0.60 | 165 | 15.25 | 376 | 946 | 3.82 / 222.83 | 2 | 8 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 28 | 15.18 | 551 | 234 | 0.23 / 215.48 | 2 | 3 |
2 | 7 | 2011.60 | 38 | 14.89 | 2930 | 1658 | 1.89 / 217.14 | 2 | 3 |
3 | 13 | 1203.92 | 18 | 15.03 | 1975 | 534 | 2.43 / 217.68 | 2 | 3 |
4 | 13 | 571.68 | 18 | 15.16 | 1199 | 327 | 2.75 / 218.00 | 2 | 4 |
5 | 13 | 105.96 | 7 | 15.28 | 561 | 60 | 2.81 / 218.06 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.26 | 377 | 949 | 3.76 / 219.01 | 2 | 4 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 28 | 15.17 | 536 | 228 | 0.23 / 211.71 | 2 | 3 |
2 | 7 | 2008.12 | 38 | 14.88 | 2926 | 1654 | 1.88 / 213.37 | 2 | 3 |
3 | 13 | 1187.12 | 18 | 15.02 | 1959 | 530 | 2.41 / 213.89 | 2 | 3 |
4 | 13 | 665.68 | 18 | 15.12 | 1306 | 355 | 2.77 / 214.25 | 2 | 4 |
5 | 13 | 124.04 | 7 | 15.27 | 581 | 62 | 2.83 / 214.31 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.25 | 373 | 939 | 3.77 / 215.25 | 2 | 4 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 28 | 15.19 | 535 | 228 | 0.23 / 207.86 | 2 | 3 |
2 | 7 | 2003.36 | 38 | 14.89 | 2918 | 1651 | 1.88 / 209.52 | 2 | 3 |
3 | 13 | 1199.88 | 18 | 15.03 | 1956 | 529 | 2.41 / 210.04 | 2 | 3 |
4 | 13 | 578.96 | 18 | 15.16 | 1182 | 323 | 2.73 / 210.37 | 2 | 4 |
5 | 13 | 101.44 | 7 | 15.28 | 533 | 57 | 2.79 / 210.42 | 2 | 4 |
6 | 13 | 18.00 | 18 | 15.30 | 429 | 118 | 2.91 / 210.54 | 2 | 3 |
7 | 8 | -0.44 | 165 | 15.24 | 374 | 940 | 3.85 / 211.48 | 2 | 9 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 28 | 15.18 | 556 | 236 | 0.24 / 204.13 | 2 | 3 |
2 | 7 | 2005.28 | 38 | 14.90 | 2932 | 1660 | 1.90 / 205.79 | 2 | 3 |
3 | 13 | 1096.52 | 18 | 15.06 | 1844 | 500 | 2.40 / 206.29 | 2 | 3 |
4 | 13 | 584.64 | 18 | 15.16 | 1203 | 328 | 2.72 / 206.62 | 2 | 4 |
5 | 13 | 101.12 | 7 | 15.29 | 548 | 59 | 2.78 / 206.68 | 2 | 4 |
6 | 13 | 18.56 | 1 | 15.32 | 424 | 6 | 2.79 / 206.68 | 2 | 2 |
7 | 8 | -0.16 | 165 | 15.26 | 379 | 954 | 3.74 / 207.64 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 28 | 15.17 | 550 | 234 | 0.23 / 200.37 | 2 | 3 |
2 | 7 | 2008.40 | 38 | 14.90 | 2934 | 1661 | 1.89 / 202.03 | 2 | 3 |
3 | 13 | 1214.84 | 18 | 15.03 | 1985 | 537 | 2.43 / 202.56 | 2 | 3 |
4 | 13 | 569.84 | 18 | 15.16 | 1181 | 322 | 2.75 / 202.89 | 2 | 4 |
5 | 13 | 97.88 | 7 | 15.29 | 547 | 59 | 2.81 / 202.94 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.25 | 377 | 949 | 3.76 / 203.89 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 28 | 15.17 | 550 | 234 | 0.23 / 196.42 | 2 | 3 |
2 | 7 | 2002.96 | 39 | 14.90 | 2921 | 1697 | 1.93 / 198.12 | 2 | 3 |
3 | 13 | 1313.24 | 18 | 15.01 | 2103 | 568 | 2.50 / 198.69 | 2 | 3 |
4 | 13 | 637.56 | 18 | 15.14 | 1274 | 347 | 2.85 / 199.03 | 2 | 4 |
5 | 13 | 104.20 | 18 | 15.28 | 549 | 151 | 3.00 / 199.18 | 2 | 5 |
6 | 8 | 0.56 | 165 | 15.26 | 376 | 947 | 3.94 / 200.13 | 2 | 10 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 28 | 15.18 | 550 | 234 | 0.23 / 192.53 | 2 | 3 |
2 | 7 | 2006.40 | 38 | 14.90 | 2931 | 1660 | 1.89 / 194.19 | 2 | 3 |
3 | 13 | 1191.80 | 18 | 15.04 | 1964 | 532 | 2.42 / 194.72 | 2 | 3 |
4 | 13 | 655.68 | 18 | 15.14 | 1285 | 350 | 2.78 / 195.07 | 2 | 4 |
5 | 13 | 118.40 | 18 | 15.28 | 575 | 158 | 2.93 / 195.23 | 2 | 5 |
6 | 8 | 0.28 | 165 | 15.25 | 380 | 956 | 3.89 / 196.19 | 2 | 9 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 28 | 15.19 | 550 | 234 | 0.23 / 188.65 | 2 | 4 |
2 | 7 | 2009.04 | 38 | 14.90 | 2924 | 1656 | 1.89 / 190.31 | 2 | 3 |
3 | 13 | 1207.00 | 18 | 15.04 | 1989 | 538 | 2.43 / 190.85 | 2 | 3 |
4 | 13 | 576.00 | 18 | 15.16 | 1180 | 322 | 2.75 / 191.17 | 2 | 4 |
5 | 13 | 94.52 | 18 | 15.28 | 551 | 152 | 2.90 / 191.32 | 2 | 5 |
6 | 8 | -0.24 | 165 | 15.25 | 388 | 976 | 3.88 / 192.30 | 2 | 4 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 28 | 15.19 | 554 | 236 | 0.24 / 184.85 | 2 | 4 |
2 | 7 | 2007.80 | 38 | 14.91 | 2930 | 1660 | 1.90 / 186.51 | 2 | 3 |
3 | 13 | 1223.12 | 18 | 15.04 | 1989 | 538 | 2.43 / 187.05 | 2 | 3 |
4 | 13 | 597.84 | 18 | 15.15 | 1213 | 331 | 2.76 / 187.38 | 2 | 4 |
5 | 13 | 114.24 | 7 | 15.28 | 572 | 61 | 2.83 / 187.45 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.27 | 387 | 975 | 3.80 / 188.42 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 28 | 15.16 | 555 | 236 | 0.24 / 181.06 | 2 | 4 |
2 | 7 | 2004.52 | 38 | 14.92 | 2924 | 1658 | 1.89 / 182.72 | 2 | 3 |
3 | 13 | 1217.36 | 18 | 15.04 | 1991 | 539 | 2.43 / 183.26 | 2 | 3 |
4 | 13 | 597.68 | 18 | 15.16 | 1209 | 330 | 2.76 / 183.59 | 2 | 4 |
5 | 13 | 109.44 | 7 | 15.31 | 554 | 59 | 2.82 / 183.65 | 2 | 4 |
6 | 8 | 0.96 | 165 | 15.28 | 384 | 968 | 3.79 / 184.62 | 2 | 7 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 28 | 15.19 | 564 | 240 | 0.24 / 177.15 | 2 | 4 |
2 | 7 | 2007.72 | 38 | 14.91 | 2931 | 1661 | 1.90 / 178.82 | 2 | 3 |
3 | 13 | 1169.40 | 18 | 15.07 | 1936 | 525 | 2.43 / 179.34 | 2 | 3 |
4 | 13 | 666.88 | 18 | 15.15 | 1299 | 354 | 2.78 / 179.69 | 2 | 4 |
5 | 13 | 122.20 | 7 | 15.30 | 571 | 61 | 2.84 / 179.76 | 2 | 4 |
6 | 13 | 17.00 | 18 | 15.31 | 423 | 117 | 2.96 / 179.87 | 2 | 3 |
7 | 8 | -0.60 | 165 | 15.26 | 380 | 957 | 3.91 / 180.83 | 2 | 4 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 28 | 15.19 | 580 | 247 | 0.25 / 173.27 | 2 | 4 |
2 | 7 | 2003.60 | 38 | 14.92 | 2922 | 1657 | 1.90 / 174.93 | 2 | 3 |
3 | 13 | 1196.52 | 18 | 15.07 | 1961 | 532 | 2.44 / 175.46 | 2 | 3 |
4 | 13 | 662.92 | 18 | 15.16 | 1294 | 353 | 2.79 / 175.82 | 2 | 4 |
5 | 13 | 126.24 | 7 | 15.31 | 578 | 62 | 2.85 / 175.88 | 2 | 4 |
6 | 13 | 18.88 | 10 | 15.34 | 431 | 66 | 2.92 / 175.94 | 2 | 3 |
7 | 8 | 0.56 | 165 | 15.28 | 385 | 971 | 3.89 / 176.91 | 2 | 5 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 28 | 15.21 | 567 | 241 | 0.24 / 169.45 | 2 | 4 |
2 | 7 | 2005.04 | 38 | 14.91 | 2910 | 1649 | 1.89 / 171.10 | 2 | 3 |
3 | 13 | 1188.32 | 18 | 15.06 | 1960 | 531 | 2.42 / 171.63 | 2 | 3 |
4 | 13 | 562.64 | 18 | 15.18 | 1185 | 324 | 2.75 / 171.95 | 2 | 4 |
5 | 13 | 98.28 | 7 | 15.30 | 557 | 60 | 2.80 / 172.01 | 2 | 4 |
6 | 13 | 44.76 | 5 | 15.32 | 469 | 36 | 2.84 / 172.05 | 2 | 4 |
7 | 8 | -0.12 | 165 | 15.27 | 389 | 980 | 3.82 / 173.03 | 2 | 6 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 28 | 15.19 | 562 | 239 | 0.24 / 165.66 | 2 | 4 |
2 | 7 | 2004.08 | 38 | 14.91 | 2927 | 1658 | 1.90 / 167.32 | 2 | 3 |
3 | 13 | 1200.72 | 18 | 15.05 | 1987 | 538 | 2.44 / 167.86 | 2 | 3 |
4 | 13 | 570.00 | 18 | 15.18 | 1174 | 321 | 2.76 / 168.18 | 2 | 4 |
5 | 13 | 106.28 | 7 | 15.31 | 557 | 60 | 2.82 / 168.24 | 2 | 5 |
6 | 8 | 0.08 | 165 | 15.28 | 385 | 971 | 3.79 / 169.21 | 2 | 8 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 28 | 15.21 | 562 | 239 | 0.24 / 161.77 | 2 | 4 |
2 | 7 | 2003.92 | 38 | 14.92 | 2927 | 1659 | 1.90 / 163.43 | 2 | 3 |
3 | 13 | 1298.88 | 18 | 15.05 | 2106 | 571 | 2.47 / 164.00 | 2 | 3 |
4 | 13 | 643.80 | 18 | 15.17 | 1278 | 349 | 2.82 / 164.35 | 2 | 4 |
5 | 13 | 120.80 | 7 | 15.32 | 574 | 62 | 2.88 / 164.41 | 2 | 5 |
6 | 13 | 57.00 | 5 | 15.33 | 479 | 37 | 2.92 / 164.45 | 2 | 4 |
7 | 8 | 0.32 | 165 | 15.29 | 386 | 974 | 3.89 / 165.42 | 2 | 6 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 28 | 15.19 | 559 | 238 | 0.24 / 157.94 | 2 | 4 |
2 | 7 | 2010.92 | 38 | 14.92 | 2937 | 1665 | 1.90 / 159.61 | 2 | 3 |
3 | 13 | 1233.48 | 18 | 15.06 | 2010 | 545 | 2.45 / 160.15 | 2 | 3 |
4 | 13 | 585.76 | 18 | 15.19 | 1204 | 329 | 2.78 / 160.48 | 2 | 4 |
5 | 13 | 111.56 | 7 | 15.31 | 568 | 61 | 2.84 / 160.54 | 2 | 5 |
6 | 8 | 0.32 | 165 | 15.28 | 392 | 988 | 3.83 / 161.53 | 2 | 5 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 28 | 15.21 | 553 | 236 | 0.24 / 154.01 | 2 | 4 |
2 | 7 | 2011.04 | 38 | 14.94 | 2934 | 1666 | 1.90 / 155.68 | 2 | 3 |
3 | 13 | 1217.72 | 18 | 15.07 | 1992 | 540 | 2.44 / 156.22 | 2 | 3 |
4 | 13 | 590.96 | 18 | 15.18 | 1211 | 331 | 2.77 / 156.55 | 2 | 4 |
5 | 13 | 117.08 | 7 | 15.31 | 578 | 62 | 2.83 / 156.61 | 2 | 4 |
6 | 13 | 60.64 | 5 | 15.32 | 499 | 38 | 2.87 / 156.65 | 2 | 4 |
7 | 13 | 52.00 | 5 | 15.32 | 492 | 38 | 2.91 / 156.69 | 2 | 4 |
8 | 13 | 46.64 | 5 | 15.32 | 485 | 37 | 2.95 / 156.72 | 2 | 4 |
9 | 8 | 0.00 | 165 | 15.27 | 389 | 980 | 3.93 / 157.70 | 2 | 5 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 28 | 15.18 | 573 | 244 | 0.24 / 150.22 | 2 | 4 |
2 | 7 | 2003.88 | 38 | 14.91 | 2928 | 1659 | 1.90 / 151.88 | 2 | 3 |
3 | 13 | 1190.60 | 18 | 15.06 | 1954 | 530 | 2.43 / 152.41 | 2 | 3 |
4 | 13 | 555.80 | 18 | 15.17 | 1163 | 318 | 2.75 / 152.73 | 2 | 4 |
5 | 13 | 98.08 | 7 | 15.30 | 554 | 59 | 2.81 / 152.79 | 2 | 5 |
6 | 8 | 0.52 | 165 | 15.28 | 392 | 988 | 3.80 / 153.78 | 2 | 6 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 28 | 15.20 | 569 | 242 | 0.24 / 146.41 | 2 | 4 |
2 | 7 | 2003.40 | 38 | 14.92 | 2941 | 1667 | 1.91 / 148.08 | 2 | 3 |
3 | 13 | 1206.20 | 18 | 15.04 | 1971 | 534 | 2.44 / 148.61 | 2 | 3 |
4 | 13 | 580.56 | 18 | 15.16 | 1197 | 327 | 2.77 / 148.94 | 2 | 4 |
5 | 13 | 112.20 | 7 | 15.31 | 558 | 60 | 2.83 / 149.00 | 2 | 4 |
6 | 8 | 0.84 | 165 | 15.27 | 389 | 980 | 3.81 / 149.98 | 2 | 9 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 28 | 15.21 | 550 | 234 | 0.23 / 142.53 | 2 | 4 |
2 | 7 | 2007.64 | 38 | 14.91 | 2929 | 1660 | 1.89 / 144.19 | 2 | 3 |
3 | 13 | 1216.08 | 18 | 15.06 | 1985 | 538 | 2.43 / 144.73 | 2 | 3 |
4 | 13 | 692.60 | 18 | 15.15 | 1347 | 367 | 2.80 / 145.09 | 2 | 4 |
5 | 13 | 133.88 | 8 | 15.30 | 611 | 75 | 2.87 / 145.17 | 2 | 5 |
6 | 8 | -0.56 | 165 | 15.27 | 397 | 1000 | 3.87 / 146.17 | 2 | 5 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 28 | 15.22 | 572 | 244 | 0.24 / 138.70 | 2 | 4 |
2 | 7 | 2005.08 | 39 | 14.93 | 2922 | 1701 | 1.95 / 140.40 | 2 | 3 |
3 | 13 | 1173.72 | 18 | 15.07 | 1927 | 523 | 2.47 / 140.92 | 2 | 3 |
4 | 13 | 554.52 | 18 | 15.20 | 1172 | 321 | 2.79 / 141.24 | 2 | 4 |
5 | 13 | 99.88 | 7 | 15.33 | 556 | 60 | 2.85 / 141.30 | 2 | 5 |
6 | 8 | -0.40 | 165 | 15.29 | 394 | 994 | 3.84 / 142.29 | 2 | 8 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 28 | 15.20 | 561 | 239 | 0.24 / 134.87 | 2 | 4 |
2 | 7 | 2005.84 | 38 | 14.95 | 2931 | 1665 | 1.90 / 136.53 | 2 | 3 |
3 | 13 | 1199.40 | 18 | 15.09 | 1973 | 536 | 2.44 / 137.07 | 2 | 3 |
4 | 13 | 582.04 | 18 | 15.20 | 1207 | 330 | 2.77 / 137.40 | 2 | 4 |
5 | 13 | 109.00 | 7 | 15.33 | 554 | 59 | 2.83 / 137.46 | 2 | 5 |
6 | 8 | 0.32 | 165 | 15.30 | 394 | 995 | 3.82 / 138.45 | 2 | 5 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 28 | 15.24 | 553 | 236 | 0.24 / 130.96 | 2 | 4 |
2 | 7 | 2002.48 | 39 | 14.94 | 2943 | 1715 | 1.95 / 132.68 | 2 | 3 |
3 | 13 | 1338.08 | 18 | 15.03 | 2146 | 581 | 2.53 / 133.26 | 2 | 3 |
4 | 13 | 534.52 | 18 | 15.22 | 1138 | 312 | 2.84 / 133.57 | 2 | 4 |
5 | 13 | 101.92 | 7 | 15.34 | 553 | 59 | 2.90 / 133.63 | 2 | 5 |
6 | 8 | 0.84 | 165 | 15.30 | 396 | 1000 | 3.90 / 134.63 | 2 | 8 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 28 | 15.21 | 574 | 244 | 0.24 / 127.10 | 2 | 4 |
2 | 7 | 2005.56 | 38 | 14.96 | 2939 | 1671 | 1.92 / 128.77 | 2 | 3 |
3 | 13 | 1195.20 | 18 | 15.07 | 1962 | 532 | 2.45 / 129.30 | 2 | 3 |
4 | 13 | 661.88 | 18 | 15.18 | 1289 | 352 | 2.80 / 129.65 | 2 | 4 |
5 | 13 | 122.56 | 7 | 15.33 | 584 | 63 | 2.86 / 129.72 | 2 | 4 |
6 | 8 | -0.04 | 165 | 15.30 | 400 | 1010 | 3.87 / 130.73 | 2 | 11 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 28 | 15.22 | 575 | 245 | 0.25 / 123.26 | 2 | 3 |
2 | 7 | 2007.96 | 38 | 14.94 | 2935 | 1666 | 1.91 / 124.92 | 2 | 2 |
3 | 13 | 1187.04 | 18 | 15.09 | 1953 | 530 | 2.44 / 125.45 | 2 | 3 |
4 | 13 | 558.36 | 18 | 15.20 | 1172 | 321 | 2.76 / 125.77 | 2 | 4 |
5 | 13 | 102.00 | 7 | 15.32 | 570 | 61 | 2.82 / 125.83 | 2 | 5 |
6 | 8 | 0.04 | 165 | 15.30 | 404 | 1020 | 3.84 / 126.85 | 2 | 6 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 28 | 15.21 | 575 | 245 | 0.24 / 119.36 | 2 | 4 |
2 | 7 | 2004.88 | 38 | 14.94 | 2940 | 1669 | 1.91 / 121.03 | 2 | 3 |
3 | 13 | 1216.52 | 18 | 15.09 | 2000 | 543 | 2.46 / 121.58 | 2 | 3 |
4 | 13 | 588.44 | 18 | 15.20 | 1209 | 331 | 2.79 / 121.91 | 2 | 4 |
5 | 13 | 113.68 | 7 | 15.33 | 572 | 61 | 2.85 / 121.97 | 2 | 5 |
6 | 13 | 56.52 | 5 | 15.34 | 484 | 37 | 2.89 / 122.01 | 2 | 4 |
7 | 8 | -0.36 | 165 | 15.29 | 398 | 1004 | 3.89 / 123.01 | 2 | 6 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 28 | 15.24 | 578 | 247 | 0.25 / 115.32 | 2 | 4 |
2 | 7 | 2004.40 | 39 | 14.94 | 2942 | 1714 | 1.96 / 117.03 | 2 | 3 |
3 | 13 | 1195.12 | 18 | 15.09 | 1972 | 536 | 2.50 / 117.57 | 2 | 3 |
4 | 13 | 561.52 | 18 | 15.22 | 1176 | 322 | 2.82 / 117.89 | 2 | 4 |
5 | 13 | 92.68 | 6 | 15.35 | 553 | 51 | 2.87 / 117.94 | 2 | 4 |
6 | 13 | 50.52 | 5 | 15.35 | 490 | 38 | 2.91 / 117.98 | 2 | 4 |
7 | 13 | 16.92 | 18 | 15.34 | 439 | 121 | 3.03 / 118.10 | 2 | 3 |
8 | 8 | 0.24 | 165 | 15.31 | 404 | 1021 | 4.05 / 119.12 | 2 | 5 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 28 | 15.22 | 580 | 247 | 0.25 / 111.46 | 2 | 4 |
2 | 7 | 2004.36 | 38 | 14.96 | 2941 | 1672 | 1.92 / 113.13 | 2 | 2 |
3 | 13 | 1195.56 | 18 | 15.09 | 1975 | 536 | 2.46 / 113.67 | 2 | 3 |
4 | 13 | 560.24 | 18 | 15.22 | 1189 | 326 | 2.78 / 114.00 | 2 | 4 |
5 | 13 | 99.16 | 7 | 15.35 | 548 | 59 | 2.84 / 114.06 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.31 | 402 | 1016 | 3.86 / 115.07 | 2 | 4 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 28 | 15.22 | 578 | 246 | 0.25 / 107.59 | 2 | 3 |
2 | 7 | 2009.36 | 38 | 14.96 | 2940 | 1671 | 1.92 / 109.26 | 2 | 2 |
3 | 13 | 1182.60 | 18 | 15.10 | 1957 | 532 | 2.45 / 109.80 | 2 | 3 |
4 | 13 | 538.04 | 18 | 15.23 | 1138 | 312 | 2.76 / 110.11 | 2 | 4 |
5 | 13 | 90.56 | 6 | 15.36 | 536 | 49 | 2.81 / 110.16 | 2 | 4 |
6 | 13 | 64.72 | 6 | 15.36 | 508 | 47 | 2.86 / 110.20 | 2 | 4 |
7 | 8 | 0.72 | 165 | 15.31 | 400 | 1010 | 3.87 / 111.22 | 2 | 6 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 28 | 15.24 | 558 | 238 | 0.24 / 103.71 | 2 | 3 |
2 | 7 | 2003.48 | 38 | 14.95 | 2929 | 1664 | 1.90 / 105.37 | 2 | 2 |
3 | 13 | 1179.60 | 18 | 15.11 | 1952 | 531 | 2.43 / 105.91 | 2 | 3 |
4 | 13 | 649.84 | 18 | 15.19 | 1293 | 354 | 2.79 / 106.26 | 2 | 4 |
5 | 13 | 118.16 | 7 | 15.34 | 585 | 63 | 2.85 / 106.32 | 2 | 4 |
6 | 8 | 0.44 | 165 | 15.30 | 406 | 1025 | 3.87 / 107.35 | 2 | 5 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 28 | 15.23 | 578 | 246 | 0.25 / 99.82 | 2 | 3 |
2 | 7 | 2006.56 | 38 | 14.96 | 2937 | 1670 | 1.92 / 101.48 | 2 | 2 |
3 | 13 | 1167.52 | 18 | 15.11 | 1945 | 529 | 2.45 / 102.01 | 2 | 3 |
4 | 13 | 670.52 | 18 | 15.20 | 1313 | 359 | 2.80 / 102.37 | 2 | 4 |
5 | 13 | 124.12 | 7 | 15.34 | 581 | 62 | 2.87 / 102.44 | 2 | 4 |
6 | 13 | 48.12 | 5 | 15.36 | 479 | 37 | 2.90 / 102.47 | 2 | 4 |
7 | 8 | 0.20 | 165 | 15.31 | 396 | 1000 | 3.90 / 103.47 | 2 | 5 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 28 | 15.23 | 585 | 249 | 0.25 / 95.93 | 2 | 3 |
2 | 7 | 2004.60 | 38 | 14.96 | 2929 | 1665 | 1.91 / 97.59 | 2 | 2 |
3 | 13 | 1093.44 | 18 | 15.13 | 1857 | 506 | 2.42 / 98.10 | 2 | 3 |
4 | 13 | 602.76 | 18 | 15.21 | 1232 | 337 | 2.76 / 98.44 | 2 | 4 |
5 | 13 | 104.36 | 7 | 15.34 | 566 | 61 | 2.82 / 98.50 | 2 | 4 |
6 | 13 | 53.68 | 5 | 15.35 | 502 | 39 | 2.86 / 98.54 | 2 | 4 |
7 | 8 | -0.48 | 165 | 15.30 | 409 | 1033 | 3.89 / 99.57 | 2 | 6 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 28 | 15.24 | 563 | 240 | 0.24 / 91.99 | 2 | 3 |
2 | 7 | 2003.60 | 38 | 14.97 | 2946 | 1676 | 1.92 / 93.66 | 2 | 2 |
3 | 13 | 1303.72 | 18 | 15.09 | 2111 | 573 | 2.49 / 94.24 | 2 | 3 |
4 | 13 | 639.64 | 18 | 15.20 | 1277 | 349 | 2.84 / 94.59 | 2 | 4 |
5 | 13 | 113.20 | 7 | 15.34 | 579 | 62 | 2.90 / 94.65 | 2 | 4 |
6 | 8 | 0.24 | 165 | 15.31 | 408 | 1031 | 3.93 / 95.68 | 2 | 4 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 28 | 15.25 | 567 | 242 | 0.24 / 88.17 | 2 | 3 |
2 | 7 | 2008.48 | 38 | 14.98 | 2931 | 1668 | 1.91 / 89.84 | 2 | 2 |
3 | 13 | 1175.44 | 18 | 15.13 | 1939 | 528 | 2.44 / 90.37 | 2 | 3 |
4 | 13 | 533.32 | 18 | 15.24 | 1135 | 311 | 2.75 / 90.68 | 2 | 4 |
5 | 13 | 88.60 | 6 | 15.36 | 533 | 49 | 2.80 / 90.73 | 2 | 4 |
6 | 8 | 0.52 | 165 | 15.32 | 403 | 1019 | 3.82 / 91.75 | 2 | 4 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 28 | 15.25 | 575 | 246 | 0.25 / 84.37 | 2 | 3 |
2 | 7 | 2009.36 | 38 | 14.99 | 2941 | 1675 | 1.92 / 86.05 | 2 | 2 |
3 | 13 | 1162.24 | 18 | 15.14 | 1939 | 528 | 2.45 / 86.58 | 2 | 3 |
4 | 13 | 522.16 | 18 | 15.25 | 1127 | 309 | 2.76 / 86.89 | 2 | 4 |
5 | 13 | 83.76 | 6 | 15.37 | 526 | 49 | 2.81 / 86.94 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.33 | 393 | 994 | 3.80 / 87.93 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 28 | 15.25 | 590 | 252 | 0.25 / 80.48 | 2 | 3 |
2 | 7 | 2003.56 | 39 | 14.98 | 2932 | 1713 | 1.96 / 82.19 | 2 | 2 |
3 | 13 | 1197.00 | 18 | 15.12 | 1970 | 536 | 2.50 / 82.73 | 2 | 3 |
4 | 13 | 572.00 | 18 | 15.23 | 1192 | 327 | 2.83 / 83.06 | 2 | 4 |
5 | 13 | 93.48 | 6 | 15.36 | 549 | 51 | 2.88 / 83.11 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.33 | 404 | 1022 | 3.90 / 84.13 | 2 | 5 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.28 | 28 | 15.23 | 577 | 246 | 0.25 / 76.57 | 2 | 3 |
2 | 7 | 2008.80 | 38 | 14.98 | 2927 | 1666 | 1.91 / 78.24 | 2 | 2 |
3 | 13 | 1199.16 | 18 | 15.10 | 1981 | 538 | 2.45 / 78.78 | 2 | 3 |
4 | 13 | 673.44 | 18 | 15.20 | 1316 | 360 | 2.81 / 79.14 | 2 | 4 |
5 | 13 | 122.36 | 7 | 15.33 | 593 | 64 | 2.87 / 79.20 | 2 | 4 |
6 | 8 | 0.24 | 165 | 15.31 | 406 | 1026 | 3.90 / 80.23 | 2 | 6 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 27 | 15.23 | 573 | 236 | 0.24 / 72.68 | 2 | 3 |
2 | 7 | 2004.40 | 39 | 14.99 | 2937 | 1717 | 1.95 / 74.40 | 2 | 2 |
3 | 13 | 1199.60 | 18 | 15.12 | 1976 | 538 | 2.49 / 74.93 | 2 | 3 |
4 | 13 | 561.80 | 18 | 15.24 | 1171 | 321 | 2.81 / 75.26 | 2 | 4 |
5 | 13 | 88.44 | 6 | 15.36 | 537 | 49 | 2.86 / 75.30 | 2 | 4 |
6 | 8 | 0.32 | 165 | 15.32 | 405 | 1024 | 3.88 / 76.33 | 2 | 4 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 27 | 15.24 | 582 | 239 | 0.24 / 68.78 | 2 | 3 |
2 | 7 | 2011.00 | 38 | 15.00 | 2944 | 1678 | 1.92 / 70.46 | 2 | 2 |
3 | 13 | 1215.84 | 18 | 15.11 | 1992 | 542 | 2.46 / 71.00 | 2 | 3 |
4 | 13 | 581.68 | 18 | 15.23 | 1201 | 329 | 2.79 / 71.33 | 2 | 4 |
5 | 13 | 104.32 | 7 | 15.36 | 559 | 60 | 2.85 / 71.39 | 2 | 4 |
6 | 13 | 46.80 | 5 | 15.37 | 485 | 37 | 2.89 / 71.42 | 2 | 4 |
7 | 8 | -0.20 | 165 | 15.32 | 403 | 1019 | 3.90 / 72.44 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 27 | 15.24 | 583 | 240 | 0.24 / 64.85 | 2 | 3 |
2 | 7 | 2004.04 | 38 | 14.99 | 2932 | 1670 | 1.91 / 66.52 | 2 | 2 |
3 | 13 | 1298.48 | 18 | 15.10 | 2106 | 572 | 2.48 / 67.10 | 2 | 3 |
4 | 13 | 640.16 | 18 | 15.22 | 1270 | 348 | 2.83 / 67.44 | 2 | 4 |
5 | 13 | 88.40 | 6 | 15.37 | 539 | 50 | 2.88 / 67.49 | 2 | 4 |
6 | 13 | 63.72 | 6 | 15.36 | 503 | 46 | 2.93 / 67.54 | 2 | 4 |
7 | 8 | 0.44 | 165 | 15.33 | 395 | 999 | 3.93 / 68.54 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 27 | 15.25 | 566 | 233 | 0.23 / 61.01 | 2 | 3 |
2 | 7 | 2003.36 | 38 | 14.99 | 2934 | 1671 | 1.90 / 62.68 | 2 | 2 |
3 | 13 | 1176.24 | 18 | 15.14 | 1940 | 529 | 2.43 / 63.21 | 2 | 3 |
4 | 13 | 560.36 | 18 | 15.24 | 1188 | 326 | 2.76 / 63.54 | 2 | 4 |
5 | 13 | 87.12 | 6 | 15.37 | 542 | 50 | 2.81 / 63.59 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.32 | 406 | 1026 | 3.84 / 64.61 | 2 | 6 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 27 | 15.26 | 574 | 236 | 0.24 / 57.03 | 2 | 3 |
2 | 7 | 2009.08 | 39 | 15.00 | 2947 | 1724 | 1.96 / 58.75 | 2 | 2 |
3 | 13 | 1178.76 | 18 | 15.13 | 1962 | 534 | 2.49 / 59.29 | 2 | 3 |
4 | 13 | 530.40 | 18 | 15.25 | 1137 | 312 | 2.81 / 59.60 | 2 | 4 |
5 | 13 | 81.64 | 6 | 15.38 | 541 | 50 | 2.86 / 59.65 | 2 | 4 |
6 | 13 | 16.80 | 18 | 15.38 | 440 | 122 | 2.98 / 59.77 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.32 | 399 | 1009 | 3.99 / 60.78 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 27 | 15.25 | 583 | 240 | 0.24 / 53.04 | 2 | 3 |
2 | 7 | 2003.52 | 39 | 15.01 | 2933 | 1717 | 1.96 / 54.76 | 2 | 2 |
3 | 13 | 1184.72 | 18 | 15.14 | 1978 | 539 | 2.50 / 55.30 | 2 | 3 |
4 | 13 | 547.20 | 18 | 15.25 | 1164 | 320 | 2.82 / 55.62 | 2 | 4 |
5 | 13 | 77.20 | 18 | 15.36 | 529 | 146 | 2.96 / 55.76 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.33 | 407 | 1029 | 3.99 / 56.79 | 2 | 7 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 27 | 15.26 | 563 | 232 | 0.23 / 48.26 | 2 | 3 |
2 | 7 | 2004.00 | 74 | 14.89 | 2917 | 3214 | 3.45 / 51.48 | 2 | 3 |
3 | 13 | 205.44 | 18 | 15.33 | 701 | 193 | 3.64 / 51.67 | 2 | 4 |
4 | 13 | 25.20 | 18 | 15.39 | 445 | 123 | 3.76 / 51.79 | 2 | 4 |
5 | 8 | -0.28 | 165 | 15.34 | 398 | 1007 | 4.77 / 52.80 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 27 | 15.26 | 575 | 237 | 0.24 / 44.21 | 2 | 3 |
2 | 7 | 1525.76 | 75 | 15.00 | 2350 | 2644 | 2.88 / 46.85 | 2 | 3 |
3 | 13 | 140.72 | 18 | 15.36 | 608 | 168 | 3.05 / 47.02 | 2 | 4 |
4 | 8 | 0.04 | 165 | 15.34 | 400 | 1012 | 4.06 / 48.03 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 27 | 15.25 | 565 | 233 | 0.23 / 40.19 | 2 | 3 |
2 | 7 | 1520.40 | 74 | 15.01 | 2340 | 2599 | 2.83 / 42.79 | 2 | 3 |
3 | 13 | 132.52 | 18 | 15.36 | 600 | 166 | 3.00 / 42.95 | 2 | 4 |
4 | 8 | 0.68 | 165 | 15.33 | 402 | 1017 | 4.01 / 43.97 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 26 | 15.26 | 547 | 217 | 0.22 / 36.12 | 2 | 3 |
2 | 10 | 1011.80 | 2 | 15.19 | 1821 | 55 | 0.27 / 36.18 | 2 | 3 |
3 | 7 | 1507.48 | 75 | 15.00 | 2332 | 2623 | 2.90 / 38.80 | 2 | 3 |
4 | 13 | 118.40 | 18 | 15.36 | 568 | 157 | 3.05 / 38.96 | 2 | 4 |
5 | 8 | 0.60 | 165 | 15.34 | 393 | 995 | 4.05 / 39.95 | 2 | 10 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 27 | 15.27 | 574 | 237 | 0.24 / 31.38 | 2 | 3 |
2 | 7 | 2005.28 | 74 | 14.90 | 2921 | 3221 | 3.46 / 34.60 | 2 | 3 |
3 | 13 | 205.56 | 18 | 15.35 | 700 | 193 | 3.65 / 34.80 | 2 | 4 |
4 | 13 | 19.04 | 18 | 15.40 | 426 | 118 | 3.77 / 34.91 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.34 | 392 | 992 | 4.76 / 35.91 | 2 | 7 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 27 | 15.26 | 568 | 234 | 0.23 / 26.66 | 2 | 3 |
2 | 7 | 2003.04 | 75 | 14.90 | 2918 | 3261 | 3.49 / 29.92 | 2 | 3 |
3 | 13 | 293.16 | 18 | 15.32 | 817 | 225 | 3.72 / 30.15 | 2 | 4 |
4 | 8 | -0.16 | 165 | 15.34 | 393 | 995 | 4.71 / 31.15 | 2 | 8 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 25 | 15.28 | 552 | 211 | 0.21 / 21.78 | 2 | 3 |
2 | 10 | 1015.36 | 3 | 15.18 | 1800 | 82 | 0.29 / 21.86 | 2 | 3 |
3 | 7 | 2008.40 | 74 | 14.90 | 2920 | 3220 | 3.51 / 25.08 | 2 | 3 |
4 | 13 | 342.64 | 18 | 15.31 | 884 | 244 | 3.76 / 25.32 | 2 | 4 |
5 | 13 | 16.28 | 18 | 15.39 | 424 | 117 | 3.87 / 25.44 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.34 | 391 | 990 | 4.86 / 26.43 | 2 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 30 | 15.25 | 562 | 257 | 0.26 / 17.19 | 2 | 2 |
2 | 3 | 869.40 | -2 | 15.64 | 0 | 0 | 0.00 / 17.19 | 2 | 2 |
3 | 3 | 923.88 | -1 | 15.67 | 0 | 0 | 0.00 / 17.19 | 2 | 2 |
4 | 7 | 2002.60 | 74 | 14.91 | 2910 | 3211 | 3.47 / 20.40 | 2 | 3 |
5 | 13 | 194.44 | 18 | 15.37 | 672 | 186 | 3.65 / 20.59 | 2 | 4 |
6 | 8 | -0.32 | 165 | 15.36 | 387 | 981 | 4.63 / 21.57 | 2 | 7 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 26 | 15.25 | 569 | 226 | 0.23 / 13.20 | 2 | 3 |
2 | 7 | 1521.04 | 74 | 15.00 | 2333 | 2590 | 2.82 / 15.79 | 2 | 3 |
3 | 13 | 134.20 | 18 | 15.36 | 582 | 161 | 2.98 / 15.95 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.34 | 389 | 985 | 3.96 / 16.93 | 2 | 5 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 26 | 15.26 | 546 | 217 | 0.22 / 9.22 | 2 | 3 |
2 | 3 | 1018.72 | 1 | 15.30 | 1822 | 28 | 0.24 / 9.25 | 2 | 3 |
3 | 7 | 1519.92 | 74 | 15.00 | 2330 | 2586 | 2.83 / 11.84 | 2 | 3 |
4 | 13 | 135.76 | 18 | 15.35 | 583 | 161 | 2.99 / 12.00 | 2 | 4 |
5 | 8 | 0.72 | 165 | 15.32 | 385 | 973 | 3.97 / 12.97 | 2 | 4 |
Average= | 3.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 32 | 15.30 | 550 | 269 | 0.27 / 5.30 | 2 | 4 |
2 | 3 | 749.72 | -5 | 15.65 | 0 | 0 | 0.00 / 5.30 | 2 | 4 |
3 | 3 | 969.92 | -1 | 15.68 | 0 | 0 | 0.00 / 5.30 | 2 | 4 |
4 | 7 | 1523.00 | 74 | 15.00 | 2327 | 2583 | 2.85 / 7.88 | 2 | 3 |
5 | 13 | 120.68 | 18 | 15.36 | 561 | 155 | 3.01 / 8.04 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.34 | 383 | 969 | 3.98 / 9.01 | 2 | 4 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 27 | 15.51 | 478 | 200 | 0.20 / 2.16 | 2 | 2 |
2 | 3 | 919.32 | -2 | 15.69 | 0 | 0 | 0.00 / 2.16 | 2 | 2 |
3 | 3 | 1042.72 | 1 | 15.33 | 1823 | 28 | 0.23 / 2.18 | 2 | 3 |
4 | 7 | 999.28 | 74 | 15.16 | 1679 | 1884 | 2.11 / 4.07 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.38 | 379 | 962 | 3.07 / 5.03 | 2 | 6 |
Average= | 2.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.64 | 27 | 15.69 | 493 | 209 | 0.21 / 0.21 | 2 | 2 |
2 | 7 | 134.76 | 74 | 15.65 | 497 | 576 | 0.78 / 0.78 | 2 | 2 |
3 | 8 | -0.16 | 240 | 15.60 | 313 | 1172 | 1.96 / 1.96 | 2 | 9 |
Average= | 1.96 (KJ/cycle) |