Cycle 80 GMT 13/12/2024 18:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 39 15.06 477 280 0.28 / 345.72 2 2
2 7 2007.84 38 14.73 2996 1677 1.96 / 347.39 2 2
3 13 1686.60 18 14.77 2589 688 2.65 / 348.08 2 2
4 13 1112.44 18 14.86 1825 488 3.13 / 348.57 2 3
5 13 526.28 18 15.02 1032 279 3.41 / 348.85 2 3
6 13 21.84 18 15.17 319 87 3.50 / 348.93 2 2
7 8 0.04 165 15.12 293 731 4.23 / 349.67 2 5
Average= 4.32
(KJ/cycle)

Cycle 79 GMT 3/12/2024 23:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 39 15.07 491 289 0.29 / 341.42 2 2
2 7 2005.68 38 14.74 3000 1680 1.97 / 343.10 2 2
3 13 1680.08 18 14.78 2592 690 2.66 / 343.79 2 2
4 13 1148.92 18 14.85 1872 500 3.16 / 344.29 2 3
5 13 531.36 18 15.02 1035 280 3.44 / 344.57 2 3
6 13 26.92 18 15.17 336 92 3.53 / 344.66 2 3
7 8 0.08 165 15.12 311 776 4.31 / 345.44 2 8
Average= 4.32
(KJ/cycle)

Cycle 78 GMT 24/11/2024 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 39 15.07 481 283 0.28 / 337.04 2 2
2 7 2006.52 38 14.74 3001 1681 1.96 / 338.72 2 2
3 13 1680.68 18 14.77 2598 691 2.65 / 339.41 2 2
4 13 1226.92 18 14.83 2007 536 3.19 / 339.95 2 3
5 13 504.32 18 15.04 1025 277 3.47 / 340.23 2 3
6 13 22.88 18 15.17 353 96 3.56 / 340.32 2 3
7 8 0.12 165 15.12 323 806 4.37 / 341.13 2 8
Average= 4.32
(KJ/cycle)

Cycle 77 GMT 14/11/2024 10:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 39 15.07 463 272 0.27 / 332.81 2 2
2 7 2007.36 38 14.76 2989 1676 1.95 / 334.48 2 2
3 13 1637.68 18 14.80 2532 675 2.62 / 335.16 2 2
4 13 1152.36 18 14.86 1883 504 3.13 / 335.66 2 3
5 13 480.44 18 15.05 971 263 3.39 / 335.92 2 3
6 13 16.96 18 15.19 313 86 3.48 / 336.01 2 4
7 8 0.04 165 15.14 300 749 4.22 / 336.76 2 9
Average= 4.32
(KJ/cycle)

Cycle 76 GMT 4/11/2024 15:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 39 15.08 468 275 0.28 / 328.58 2 2
2 7 2023.00 38 14.73 3026 1694 1.97 / 330.27 2 2
3 13 1616.80 18 14.79 2501 666 2.63 / 330.94 2 2
4 13 1128.76 18 14.87 1846 494 3.13 / 331.43 2 3
5 13 539.24 18 15.04 1052 285 3.41 / 331.72 2 3
6 13 14.40 18 15.18 310 85 3.50 / 331.80 2 3
7 8 0.00 165 15.14 293 732 4.23 / 332.53 2 8
Average= 4.32
(KJ/cycle)

Cycle 75 GMT 25/10/2024 21: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 39 15.08 493 290 0.29 / 324.38 2 2
2 7 2007.80 38 14.75 3004 1684 1.97 / 326.07 2 2
3 13 1610.76 18 14.80 2489 663 2.64 / 326.73 2 2
4 13 1170.24 18 14.86 1902 509 3.15 / 327.24 2 3
5 13 537.36 18 15.03 1069 289 3.43 / 327.53 2 3
6 8 0.08 165 15.15 310 775 4.21 / 328.30 2 5
Average= 4.32
(KJ/cycle)

Cycle 74 GMT 16/10/2024 2:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 39 15.09 488 287 0.29 / 320.17 2 2
2 7 2005.88 38 14.75 2987 1674 1.96 / 321.84 2 2
3 13 1640.80 18 14.80 2529 674 2.64 / 322.51 2 2
4 13 1112.84 18 14.87 1832 490 3.13 / 323.00 2 3
5 13 535.96 18 15.03 1058 286 3.41 / 323.29 2 3
6 8 0.36 165 15.13 322 804 4.22 / 324.09 2 3
Average= 4.32
(KJ/cycle)

Cycle 73 GMT 6/10/2024 7:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.44 39 15.09 489 288 0.29 / 315.79 2 2
2 7 2009.40 38 14.75 3004 1684 1.97 / 317.48 2 2
3 13 1648.56 18 14.80 2536 676 2.65 / 318.15 2 2
4 13 1155.08 18 14.87 1886 505 3.15 / 318.66 2 3
5 13 521.08 18 15.05 1035 280 3.43 / 318.94 2 3
6 8 -0.12 165 15.16 319 798 4.23 / 319.73 2 5
7 14 -0.12 30 15.13 317 144 4.37 / 319.88 2 5
Average= 4.32
(KJ/cycle)

Cycle 72 GMT 26/ 9/2024 13:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 39 15.10 487 287 0.29 / 311.57 2 2
2 7 2006.64 38 14.74 3009 1685 1.97 / 313.25 2 2
3 13 1687.52 18 14.79 2581 687 2.66 / 313.94 2 2
4 13 1149.92 18 14.87 1878 503 3.16 / 314.44 2 3
5 13 519.12 18 15.04 1047 283 3.45 / 314.72 2 3
6 8 0.16 165 15.16 312 780 4.23 / 315.50 2 6
Average= 4.32
(KJ/cycle)

Cycle 71 GMT 16/ 9/2024 18:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 39 15.10 487 287 0.29 / 307.36 2 2
2 7 2007.08 38 14.75 2994 1678 1.96 / 309.04 2 2
3 13 1635.36 18 14.79 2519 671 2.64 / 309.71 2 2
4 13 1122.88 18 14.88 1842 493 3.13 / 310.20 2 3
5 13 573.12 18 15.03 1124 304 3.43 / 310.50 2 3
6 8 0.08 165 15.16 310 775 4.21 / 311.28 2 8
Average= 4.32
(KJ/cycle)

Cycle 70 GMT 7/ 9/2024 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 39 15.12 457 269 0.27 / 303.12 2 2
2 7 2023.52 38 14.74 3031 1698 1.97 / 304.82 2 2
3 13 1607.08 18 14.79 2500 666 2.63 / 305.48 2 2
4 13 1127.08 18 14.88 1856 497 3.13 / 305.98 2 3
5 13 535.48 18 15.04 1074 291 3.42 / 306.27 2 3
6 8 0.40 165 15.16 320 800 4.22 / 307.07 2 7
Average= 4.32
(KJ/cycle)

Cycle 69 GMT 28/ 8/2024 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 39 15.11 455 268 0.27 / 298.89 2 2
2 7 2006.28 38 14.77 3000 1684 1.95 / 300.57 2 2
3 13 1650.16 18 14.81 2542 678 2.63 / 301.25 2 3
4 13 1168.12 18 14.87 1923 515 3.14 / 301.77 2 3
5 13 568.08 18 15.04 1119 303 3.45 / 302.07 2 3
6 8 0.16 165 15.17 312 781 4.23 / 302.85 2 3
Average= 4.33
(KJ/cycle)

Cycle 68 GMT 18/ 8/2024 10:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 39 15.13 467 276 0.28 / 294.60 2 2
2 7 2008.44 38 14.76 3014 1690 1.97 / 296.29 2 2
3 13 1684.96 18 14.80 2575 686 2.65 / 296.97 2 2
4 13 1143.64 18 14.91 1860 499 3.15 / 297.47 2 3
5 13 513.08 18 15.07 1022 277 3.43 / 297.75 2 3
6 13 40.88 18 15.21 381 104 3.53 / 297.85 2 4
7 8 0.12 165 15.18 306 766 4.30 / 298.62 2 6
Average= 4.33
(KJ/cycle)

Cycle 67 GMT 8/ 8/2024 16:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 39 15.12 474 280 0.28 / 290.14 2 2
2 7 2006.32 38 14.77 3006 1687 1.97 / 291.83 2 2
3 13 1602.60 18 14.83 2483 663 2.63 / 292.49 2 3
4 13 1123.20 18 14.91 1861 499 3.13 / 292.99 2 3
5 13 502.20 18 15.08 1027 279 3.41 / 293.27 2 3
6 13 81.16 18 15.20 445 122 3.53 / 293.39 2 4
7 8 0.28 165 15.18 313 784 4.31 / 294.18 2 5
8 14 0.28 30 15.16 315 143 4.46 / 294.32 2 9
Average= 4.33
(KJ/cycle)

Cycle 66 GMT 29/ 7/2024 21:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 39 15.12 478 282 0.28 / 285.96 2 2
2 7 2007.16 38 14.75 2985 1673 1.95 / 287.63 2 2
3 13 1636.56 18 14.81 2527 674 2.63 / 288.30 2 3
4 13 1098.80 18 14.90 1818 488 3.12 / 288.79 2 3
5 13 520.84 18 15.06 1055 286 3.40 / 289.08 2 3
6 8 0.20 165 15.18 314 786 4.19 / 289.87 2 7
Average= 4.33
(KJ/cycle)

Cycle 65 GMT 20/ 7/2024 3: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 39 15.10 472 278 0.28 / 281.72 2 2
2 7 2006.60 38 14.75 2992 1677 1.95 / 283.40 2 2
3 13 1632.68 18 14.80 2532 675 2.63 / 284.07 2 2
4 13 1186.84 18 14.87 1928 516 3.15 / 284.59 2 3
5 13 584.44 18 15.04 1113 301 3.45 / 284.89 2 3
6 8 -0.04 165 15.17 314 786 4.23 / 285.68 2 6
Average= 4.33
(KJ/cycle)

Cycle 64 GMT 10/ 7/2024 8:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 39 15.12 486 287 0.29 / 277.19 2 2
2 7 2023.72 38 14.74 3035 1700 1.99 / 278.89 2 2
3 13 1662.72 18 14.79 2576 686 2.67 / 279.58 2 2
4 13 1131.52 18 14.89 1878 503 3.18 / 280.08 2 3
5 13 579.76 18 15.04 1151 312 3.49 / 280.39 2 3
6 13 46.20 18 15.20 398 109 3.60 / 280.50 2 3
7 8 -0.24 165 15.17 319 798 4.39 / 281.30 2 6
8 14 -0.24 30 15.14 316 144 4.54 / 281.44 2 8
Average= 4.33
(KJ/cycle)

Cycle 63 GMT 30/ 6/2024 13:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 39 15.10 482 284 0.28 / 272.89 2 2
2 7 2007.16 38 14.77 3011 1690 1.97 / 274.58 2 2
3 13 1686.20 18 14.82 2589 691 2.66 / 275.27 2 2
4 13 1150.80 18 14.89 1911 512 3.18 / 275.78 2 3
5 13 563.64 18 15.07 1101 299 3.48 / 276.08 2 3
6 8 0.52 165 15.19 329 825 4.30 / 276.91 2 10
Average= 4.33
(KJ/cycle)

Cycle 62 GMT 20/ 6/2024 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 39 15.14 484 286 0.29 / 268.50 2 2
2 7 2006.28 39 14.75 3000 1726 2.01 / 270.22 2 2
3 13 1597.36 18 14.81 2488 663 2.67 / 270.88 2 2
4 13 1158.56 18 14.89 1925 516 3.19 / 271.40 2 3
5 13 523.84 18 15.07 1070 290 3.48 / 271.69 2 3
6 13 49.60 18 15.21 406 111 3.59 / 271.80 2 3
7 8 0.04 165 15.18 321 804 4.40 / 272.61 2 6
Average= 4.33
(KJ/cycle)

Cycle 61 GMT 11/ 6/2024 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 39 15.14 476 281 0.28 / 264.26 2 2
2 7 2021.68 38 14.76 3006 1686 1.97 / 265.95 2 2
3 13 1650.20 18 14.82 2544 679 2.65 / 266.63 2 2
4 13 1078.16 18 14.93 1774 477 3.12 / 267.10 2 3
5 13 547.68 18 15.09 1098 298 3.42 / 267.40 2 3
6 8 0.16 165 15.19 322 807 4.23 / 268.21 2 5
Average= 4.33
(KJ/cycle)

Cycle 60 GMT 1/ 6/2024 5:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 39 15.14 472 279 0.28 / 259.77 2 2
2 7 2007.60 38 14.76 3006 1686 1.96 / 261.45 2 2
3 13 1693.96 18 14.81 2606 695 2.66 / 262.15 2 2
4 13 1093.40 18 14.92 1843 495 3.15 / 262.64 2 3
5 13 525.44 18 15.09 1071 291 3.45 / 262.93 2 3
6 13 56.84 18 15.22 414 113 3.56 / 263.05 2 3
7 8 -0.20 165 15.19 315 790 4.35 / 263.84 2 5
8 14 -0.20 30 15.16 322 146 4.49 / 263.98 2 9
Average= 4.33
(KJ/cycle)

Cycle 59 GMT 22/ 5/2024 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 39 15.15 478 282 0.28 / 255.48 2 2
2 7 2006.76 38 14.77 3005 1687 1.97 / 257.17 2 2
3 13 1600.84 18 14.84 2483 663 2.63 / 257.83 2 2
4 13 1122.80 18 14.92 1853 498 3.13 / 258.33 2 3
5 13 492.88 18 15.10 1013 275 3.41 / 258.61 2 3
6 13 29.24 18 15.23 373 102 3.51 / 258.71 2 3
7 8 0.28 165 15.20 310 777 4.28 / 259.49 2 6
Average= 4.32
(KJ/cycle)

Cycle 58 GMT 12/ 5/2024 16:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 39 15.15 491 290 0.29 / 251.04 2 2
2 7 2005.64 38 14.77 3007 1688 1.98 / 252.73 2 2
3 13 1635.96 18 14.83 2537 677 2.66 / 253.41 2 2
4 13 1071.80 18 14.95 1766 475 3.13 / 253.88 2 3
5 13 455.36 18 15.13 947 258 3.39 / 254.14 2 3
6 13 43.44 18 15.25 395 108 3.50 / 254.25 2 3
7 8 -0.08 165 15.21 319 801 4.30 / 255.05 2 7
8 14 -0.08 30 15.18 331 151 4.45 / 255.20 2 7
Average= 4.33
(KJ/cycle)

Cycle 57 GMT 2/ 5/2024 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 39 15.12 489 288 0.29 / 246.66 2 2
2 7 2017.16 38 14.77 3020 1695 1.98 / 248.36 2 2
3 13 1668.36 18 14.82 2566 685 2.67 / 249.04 2 2
4 13 1137.36 18 14.92 1863 500 3.17 / 249.54 2 3
5 13 532.12 18 15.10 1059 288 3.46 / 249.83 2 3
6 13 65.04 18 15.23 423 116 3.57 / 249.95 2 3
7 8 -0.04 165 15.20 322 808 4.38 / 250.75 2 5
Average= 4.32
(KJ/cycle)

Cycle 56 GMT 23/ 4/2024 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 39 15.13 486 287 0.29 / 242.33 2 2
2 7 2022.04 38 14.76 3014 1690 1.98 / 244.02 2 2
3 13 1639.76 18 14.82 2532 675 2.65 / 244.69 2 2
4 13 1077.92 18 14.94 1782 479 3.13 / 245.17 2 3
5 13 533.92 18 15.09 1079 293 3.42 / 245.47 2 3
6 13 51.56 18 15.23 399 109 3.53 / 245.57 2 4
7 8 0.16 165 15.19 319 800 4.33 / 246.37 2 6
Average= 4.32
(KJ/cycle)

Cycle 55 GMT 13/ 4/2024 8: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 39 15.14 483 285 0.29 / 237.88 2 2
2 7 2023.88 39 14.76 3005 1730 2.01 / 239.61 2 2
3 13 1694.56 18 14.81 2604 694 2.71 / 240.31 2 2
4 13 1125.76 18 14.93 1848 497 3.21 / 240.81 2 3
5 13 554.40 18 15.09 1093 297 3.50 / 241.10 2 3
6 13 61.84 18 15.24 425 117 3.62 / 241.22 2 3
7 8 0.20 165 15.19 328 822 4.44 / 242.04 2 8
Average= 4.32
(KJ/cycle)

Cycle 54 GMT 3/ 4/2024 13:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 39 15.14 465 275 0.27 / 233.53 2 2
2 7 2007.52 38 14.76 3006 1686 1.96 / 235.21 2 2
3 13 1611.08 18 14.83 2511 670 2.63 / 235.89 2 2
4 13 1132.44 18 14.91 1890 507 3.14 / 236.39 2 3
5 13 474.16 18 15.11 1001 272 3.41 / 236.66 2 3
6 13 51.28 18 15.24 408 112 3.52 / 236.78 2 3
7 8 0.24 165 15.20 328 823 4.34 / 237.60 2 5
Average= 4.32
(KJ/cycle)

Cycle 53 GMT 24/ 3/2024 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 39 15.14 458 270 0.27 / 229.10 2 2
2 7 2007.24 38 14.78 2991 1680 1.95 / 230.78 2 2
3 13 1697.92 18 14.83 2592 692 2.64 / 231.48 2 2
4 13 1199.12 18 14.92 1939 521 3.16 / 232.00 2 3
5 13 591.72 18 15.09 1139 309 3.47 / 232.31 2 3
6 13 58.08 18 15.24 421 115 3.59 / 232.42 2 3
7 8 -0.08 165 15.21 332 833 4.42 / 233.25 2 7
Average= 4.32
(KJ/cycle)

Cycle 52 GMT 15/ 3/2024 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 39 15.15 481 284 0.28 / 224.78 2 2
2 7 2010.96 38 14.77 2999 1683 1.97 / 226.47 2 2
3 13 1653.88 18 14.82 2550 680 2.65 / 227.15 2 2
4 13 1118.68 18 14.93 1836 493 3.14 / 227.64 2 3
5 13 490.08 18 15.12 1004 273 3.41 / 227.91 2 3
6 13 37.04 18 15.25 391 107 3.52 / 228.02 2 3
7 8 0.00 165 15.20 324 813 4.33 / 228.83 2 6
Average= 4.32
(KJ/cycle)

Cycle 51 GMT 5/ 3/2024 5:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.16 39 15.15 491 290 0.29 / 220.47 2 2
2 7 2008.28 38 14.78 3022 1697 1.99 / 222.16 2 2
3 13 1598.28 18 14.85 2479 663 2.65 / 222.83 2 2
4 13 1164.40 18 14.92 1923 516 3.17 / 223.34 2 3
5 13 406.56 18 15.16 906 247 3.41 / 223.59 2 3
6 13 42.84 18 15.26 392 108 3.52 / 223.70 2 3
7 8 0.12 165 15.21 319 801 4.32 / 224.50 2 6
Average= 4.32
(KJ/cycle)

Cycle 50 GMT 24/ 2/2024 10:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.12 39 15.16 500 296 0.30 / 216.06 2 2
2 7 2007.24 38 14.79 2992 1682 1.98 / 217.74 2 2
3 13 1689.92 18 14.85 2586 691 2.67 / 218.43 2 2
4 13 1152.36 18 14.94 1872 503 3.17 / 218.94 2 3
5 13 652.36 18 15.08 1212 329 3.50 / 219.27 2 3
6 13 54.44 18 15.26 411 113 3.61 / 219.38 2 4
7 8 0.00 165 15.21 318 798 4.41 / 220.18 2 4
Average= 4.32
(KJ/cycle)

Cycle 49 GMT 14/ 2/2024 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 39 15.17 482 285 0.29 / 211.70 2 2
2 7 2008.12 38 14.79 2997 1684 1.97 / 213.39 2 2
3 13 1607.68 18 14.85 2487 665 2.63 / 214.05 2 3
4 13 1047.72 18 14.98 1768 477 3.11 / 214.53 2 3
5 13 488.72 18 15.13 1018 277 3.39 / 214.81 2 3
6 13 51.64 18 15.26 422 116 3.50 / 214.92 2 4
7 8 0.04 165 15.21 336 843 4.35 / 215.77 2 7
Average= 4.32
(KJ/cycle)

Cycle 48 GMT 4/ 2/2024 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 39 15.17 486 288 0.29 / 207.33 2 2
2 7 2007.04 38 14.79 2993 1682 1.97 / 209.01 2 2
3 13 1652.88 18 14.84 2543 679 2.65 / 209.69 2 2
4 13 1163.84 18 14.94 1890 508 3.16 / 210.20 2 3
5 13 569.88 18 15.11 1109 302 3.46 / 210.50 2 3
6 13 50.84 18 15.25 405 111 3.57 / 210.61 2 3
7 8 0.08 165 15.22 320 804 4.37 / 211.42 2 5
Average= 4.31
(KJ/cycle)

Cycle 47 GMT 26/ 1/2024 3: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 39 15.18 494 292 0.29 / 202.85 2 2
2 7 2006.76 38 14.78 3011 1691 1.98 / 204.54 2 2
3 13 1678.08 18 14.86 2571 688 2.67 / 205.23 2 2
4 13 1092.00 18 14.98 1797 485 3.16 / 205.71 2 3
5 13 516.56 18 15.15 1016 277 3.43 / 205.99 2 3
6 13 43.28 18 15.28 378 104 3.54 / 206.10 2 3
7 8 -0.08 165 15.24 320 805 4.34 / 206.90 2 8
8 14 -0.08 30 15.21 316 144 4.49 / 207.04 2 9
Average= 4.31
(KJ/cycle)

Cycle 46 GMT 16/ 1/2024 8:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 39 15.17 489 289 0.29 / 198.50 2 2
2 7 2006.56 38 14.80 3005 1690 1.98 / 200.19 2 2
3 13 1602.40 18 14.88 2471 662 2.64 / 200.85 2 2
4 13 1115.60 18 14.97 1838 495 3.14 / 201.35 2 3
5 13 480.08 18 15.17 974 266 3.40 / 201.62 2 3
6 13 29.32 18 15.28 376 103 3.51 / 201.72 2 3
7 8 0.28 165 15.24 334 840 4.35 / 202.56 2 8
Average= 4.31
(KJ/cycle)

Cycle 45 GMT 6/ 1/2024 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 39 15.19 484 287 0.29 / 194.15 2 2
2 7 2006.04 38 14.79 2993 1682 1.97 / 195.83 2 2
3 13 1693.68 18 14.85 2614 699 2.67 / 196.53 2 2
4 13 1153.08 18 14.96 1871 504 3.17 / 197.03 2 3
5 13 568.52 18 15.13 1093 298 3.47 / 197.33 2 3
6 13 24.12 18 15.29 330 91 3.56 / 197.42 2 3
7 8 0.24 165 15.24 316 795 4.35 / 198.21 2 6
Average= 4.31
(KJ/cycle)

Cycle 44 GMT 27/12/2023 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 39 15.18 487 288 0.29 / 189.78 2 2
2 7 2021.28 38 14.78 3002 1686 1.97 / 191.47 2 2
3 13 1616.04 18 14.85 2494 667 2.64 / 192.14 2 2
4 13 1174.32 18 14.95 1913 515 3.16 / 192.65 2 3
5 13 566.52 18 15.12 1123 306 3.46 / 192.96 2 3
6 13 34.96 18 15.27 382 105 3.57 / 193.06 2 3
7 8 0.04 165 15.24 317 797 4.36 / 193.86 2 9
Average= 4.31
(KJ/cycle)

Cycle 43 GMT 18/12/2023 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 39 15.19 482 286 0.29 / 185.48 2 2
2 7 2011.48 38 14.80 3006 1691 1.98 / 187.17 2 2
3 13 1606.40 18 14.87 2499 669 2.64 / 187.84 2 2
4 13 1123.00 18 14.97 1841 496 3.14 / 188.33 2 3
5 13 478.52 18 15.17 974 266 3.41 / 188.60 2 3
6 13 23.20 18 15.30 364 100 3.51 / 188.70 2 3
7 8 0.08 165 15.25 317 798 4.30 / 189.49 2 6
Average= 4.31
(KJ/cycle)

Cycle 42 GMT 8/12/2023 5:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 39 15.20 500 296 0.30 / 181.13 2 2
2 7 2006.36 38 14.80 3013 1695 1.99 / 182.82 2 2
3 13 1650.68 18 14.87 2537 679 2.67 / 183.50 2 2
4 13 1114.04 18 14.98 1850 499 3.17 / 184.00 2 3
5 13 542.24 18 15.14 1088 297 3.47 / 184.30 2 3
6 13 17.96 18 15.29 344 95 3.56 / 184.39 2 3
7 8 0.16 165 15.25 317 798 4.36 / 185.19 2 9
Average= 4.31
(KJ/cycle)

Cycle 41 GMT 28/11/2023 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 39 15.19 494 293 0.29 / 176.94 2 2
2 7 2006.48 38 14.80 3008 1692 1.98 / 178.63 2 2
3 13 1556.72 18 14.89 2425 650 2.63 / 179.28 2 3
4 13 1084.24 18 15.00 1785 482 3.12 / 179.76 2 3
5 13 498.96 18 15.17 998 273 3.39 / 180.03 2 3
6 8 0.12 165 15.27 318 801 4.19 / 180.83 2 8
Average= 4.31
(KJ/cycle)

Cycle 40 GMT 18/11/2023 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 39 15.21 504 299 0.30 / 172.59 2 2
2 7 2007.48 38 14.79 2999 1685 1.98 / 174.28 2 2
3 13 1558.28 18 14.88 2418 648 2.63 / 174.93 2 2
4 13 1123.12 18 14.98 1841 496 3.13 / 175.42 2 3
5 13 487.24 18 15.15 1025 280 3.41 / 175.70 2 3
6 13 20.52 18 15.29 377 104 3.51 / 175.81 2 3
7 8 0.24 165 15.24 332 835 4.35 / 176.64 2 6
Average= 4.31
(KJ/cycle)

Cycle 39 GMT 8/11/2023 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 39 15.21 490 291 0.29 / 168.27 2 2
2 7 2010.84 38 14.81 3018 1698 1.99 / 169.97 2 2
3 13 1659.52 18 14.87 2562 686 2.67 / 170.66 2 2
4 13 1121.56 18 14.99 1855 501 3.18 / 171.16 2 3
5 13 524.84 18 15.16 1065 291 3.47 / 171.45 2 3
6 8 0.20 165 15.26 336 846 4.31 / 172.30 2 8
Average= 4.31
(KJ/cycle)

Cycle 38 GMT 30/10/2023 3:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 39 15.21 500 297 0.30 / 163.99 2 2
2 7 2022.72 38 14.81 3023 1701 2.00 / 165.70 2 2
3 13 1608.64 18 14.89 2532 679 2.68 / 166.37 2 2
4 13 1124.84 18 14.98 1888 509 3.19 / 166.88 2 3
5 13 497.84 18 15.17 1038 283 3.47 / 167.17 2 3
6 8 0.12 165 15.28 324 817 4.29 / 167.98 2 7
Average= 4.31
(KJ/cycle)

Cycle 37 GMT 20/10/2023 8:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 39 15.20 501 297 0.30 / 159.73 2 2
2 7 2006.48 38 14.79 3018 1696 1.99 / 161.43 2 2
3 13 1638.24 18 14.88 2532 678 2.67 / 162.11 2 2
4 13 1140.28 18 14.99 1881 508 3.18 / 162.61 2 3
5 13 502.44 18 15.18 999 273 3.45 / 162.89 2 3
6 8 0.00 165 15.28 322 812 4.26 / 163.70 2 4
Average= 4.31
(KJ/cycle)

Cycle 36 GMT 10/10/2023 14:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 39 15.23 496 295 0.29 / 155.41 2 2
2 7 2022.68 38 14.80 3017 1697 1.99 / 157.10 2 2
3 13 1656.60 18 14.86 2560 685 2.68 / 157.79 2 2
4 13 1160.12 18 14.97 1946 524 3.20 / 158.31 2 3
5 13 517.72 18 15.17 1062 290 3.49 / 158.60 2 3
6 8 0.00 165 15.28 330 832 4.32 / 159.43 2 7
Average= 4.31
(KJ/cycle)

Cycle 35 GMT 30/ 9/2023 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 39 15.22 495 294 0.29 / 151.05 2 2
2 7 2006.48 38 14.82 3022 1702 2.00 / 152.75 2 2
3 13 1646.04 18 14.89 2562 687 2.68 / 153.44 2 2
4 13 1157.40 18 14.99 1925 519 3.20 / 153.96 2 3
5 13 570.96 18 15.16 1146 313 3.51 / 154.27 2 3
6 8 0.32 165 15.28 334 842 4.36 / 155.11 2 6
Average= 4.31
(KJ/cycle)

Cycle 34 GMT 21/ 9/2023 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 39 15.21 494 293 0.29 / 146.81 2 2
2 7 2009.00 38 14.83 3010 1696 1.99 / 148.51 2 2
3 13 1611.92 18 14.90 2485 666 2.66 / 149.17 2 2
4 13 1122.40 18 15.01 1839 497 3.15 / 149.67 2 3
5 13 489.76 18 15.20 982 269 3.42 / 149.94 2 3
6 8 0.36 165 15.29 323 815 4.24 / 150.76 2 6
Average= 4.31
(KJ/cycle)

Cycle 33 GMT 11/ 9/2023 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 38 15.20 513 296 0.30 / 142.44 2 2
2 7 2005.72 39 14.83 2988 1728 2.02 / 144.17 2 2
3 13 1630.72 18 14.91 2506 673 2.70 / 144.84 2 2
4 13 1103.00 18 15.02 1812 490 3.19 / 145.33 2 3
5 13 509.28 18 15.19 1013 277 3.46 / 145.61 2 3
6 13 18.72 18 15.34 323 89 3.55 / 145.70 2 3
7 8 0.32 165 15.28 326 822 4.38 / 146.52 2 7
Average= 4.31
(KJ/cycle)

Cycle 32 GMT 1/ 9/2023 11:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 38 15.22 471 272 0.27 / 137.93 2 2
2 7 2022.08 38 14.83 3021 1702 1.97 / 139.63 2 2
3 13 1697.24 18 14.89 2637 707 2.68 / 140.34 2 2
4 13 1117.68 18 15.00 1876 507 3.19 / 140.85 2 3
5 13 622.76 18 15.16 1213 331 3.52 / 141.18 2 3
6 13 17.84 18 15.32 372 103 3.62 / 141.28 2 3
7 8 -0.48 165 15.27 343 864 4.49 / 142.14 2 7
Average= 4.31
(KJ/cycle)

Cycle 31 GMT 22/ 8/2023 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 38 15.21 513 297 0.30 / 133.69 2 2
2 7 2022.56 38 14.82 3035 1709 2.01 / 135.40 2 2
3 13 1645.92 18 14.90 2535 680 2.69 / 136.08 2 2
4 13 1072.80 18 15.03 1793 485 3.17 / 136.57 2 3
5 13 446.72 18 15.20 960 263 3.43 / 136.83 2 3
6 8 0.40 165 15.29 328 827 4.26 / 137.66 2 6
Average= 4.30
(KJ/cycle)

Cycle 30 GMT 12/ 8/2023 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 38 15.22 498 288 0.29 / 129.37 2 2
2 7 2021.60 38 14.82 3026 1704 1.99 / 131.07 2 2
3 13 1658.92 18 14.90 2578 691 2.68 / 131.77 2 2
4 13 1117.80 18 15.02 1873 506 3.19 / 132.27 2 3
5 13 484.68 18 15.21 1015 278 3.47 / 132.55 2 3
6 8 0.16 165 15.29 336 848 4.32 / 133.40 2 6
Average= 4.30
(KJ/cycle)

Cycle 29 GMT 3/ 8/2023 4: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 38 15.24 494 286 0.29 / 124.92 2 2
2 7 2006.52 38 14.82 3024 1703 1.99 / 126.62 2 2
3 13 1681.64 18 14.90 2589 694 2.68 / 127.32 2 2
4 13 1143.32 18 15.00 1917 518 3.20 / 127.83 2 3
5 13 553.40 18 15.17 1119 306 3.51 / 128.14 2 3
6 13 15.60 18 15.33 365 101 3.61 / 128.24 2 3
7 8 0.04 165 15.28 334 842 4.45 / 129.08 2 7
Average= 4.30
(KJ/cycle)

Cycle 28 GMT 24/ 7/2023 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 38 15.23 500 289 0.29 / 120.54 2 2
2 7 2008.76 38 14.84 3015 1700 1.99 / 122.24 2 2
3 13 1609.44 18 14.91 2495 670 2.66 / 122.91 2 2
4 13 1076.56 18 15.03 1783 482 3.14 / 123.39 2 3
5 13 493.48 18 15.21 987 270 3.41 / 123.66 2 3
6 8 0.28 165 15.30 326 823 4.23 / 124.49 2 7
7 14 0.28 30 15.29 319 146 4.38 / 124.63 2 8
Average= 4.30
(KJ/cycle)

Cycle 27 GMT 14/ 7/2023 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 38 15.24 489 283 0.28 / 116.27 2 2
2 7 2006.44 38 14.85 3013 1700 1.98 / 117.97 2 2
3 13 1598.08 18 14.92 2500 671 2.65 / 118.64 2 2
4 13 1115.92 18 15.01 1888 510 3.16 / 119.15 2 3
5 13 467.48 18 15.22 990 271 3.44 / 119.42 2 3
6 8 0.12 165 15.30 328 828 4.26 / 120.25 2 8
Average= 4.29
(KJ/cycle)

Cycle 26 GMT 4/ 7/2023 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 38 15.24 500 290 0.29 / 111.84 2 2
2 7 2022.84 38 14.83 3041 1714 2.00 / 113.55 2 2
3 13 1614.28 18 14.94 2498 672 2.68 / 114.22 2 2
4 13 1082.44 18 15.04 1834 497 3.17 / 114.72 2 3
5 13 473.24 18 15.21 1011 277 3.45 / 115.00 2 3
6 8 0.04 165 15.30 332 838 4.29 / 115.83 2 5
7 14 0.04 30 15.28 332 152 4.44 / 115.99 2 8
Average= 4.30
(KJ/cycle)

Cycle 25 GMT 25/ 6/2023 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 38 15.26 469 272 0.27 / 107.31 2 2
2 7 2006.44 38 14.86 2998 1693 1.96 / 109.01 2 2
3 13 1672.96 18 14.93 2582 694 2.66 / 109.70 2 2
4 13 1096.56 18 15.04 1816 492 3.15 / 110.19 2 3
5 13 530.44 18 15.22 1039 285 3.44 / 110.48 2 3
6 13 23.52 18 15.35 328 91 3.53 / 110.57 2 3
7 8 -0.04 165 15.31 329 831 4.36 / 111.40 2 8
8 14 -0.04 30 15.28 327 150 4.51 / 111.55 2 7
Average= 4.29
(KJ/cycle)

Cycle 24 GMT 15/ 6/2023 6:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 38 15.23 510 295 0.30 / 103.10 2 2
2 7 2023.64 38 14.84 3023 1705 2.00 / 104.81 2 2
3 13 1608.64 18 14.93 2483 667 2.67 / 105.48 2 2
4 13 1088.52 18 15.05 1788 484 3.15 / 105.96 2 3
5 13 513.00 18 15.22 1012 277 3.43 / 106.24 2 3
6 8 -0.08 165 15.31 318 803 4.23 / 107.04 2 8
Average= 4.28
(KJ/cycle)

Cycle 23 GMT 5/ 6/2023 11:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 38 15.26 492 285 0.29 / 98.77 2 2
2 7 2011.72 38 14.85 3013 1700 1.99 / 100.47 2 2
3 13 1643.80 18 14.93 2552 686 2.67 / 101.16 2 2
4 13 1139.56 18 15.04 1871 507 3.18 / 101.67 2 3
5 13 494.76 18 15.21 1035 283 3.46 / 101.95 2 3
6 8 0.44 165 15.30 341 861 4.32 / 102.81 2 5
Average= 4.28
(KJ/cycle)

Cycle 22 GMT 26/ 5/2023 17:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 38 15.26 507 294 0.29 / 94.48 2 2
2 7 2006.12 38 14.86 2989 1688 1.98 / 96.17 2 2
3 13 1592.72 18 14.95 2475 666 2.65 / 96.83 2 2
4 13 1074.68 18 15.06 1782 483 3.13 / 97.32 2 3
5 13 493.88 18 15.22 987 270 3.40 / 97.59 2 3
6 13 26.00 18 15.36 332 92 3.49 / 97.68 2 3
7 8 0.08 165 15.31 320 808 4.30 / 98.49 2 7
Average= 4.28
(KJ/cycle)

Cycle 21 GMT 16/ 5/2023 22:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 38 15.25 480 278 0.28 / 90.19 2 2
2 7 2022.16 39 14.86 3008 1743 2.02 / 91.93 2 2
3 13 1538.52 18 14.96 2409 649 2.67 / 92.58 2 2
4 13 1080.64 18 15.06 1797 487 3.16 / 93.07 2 3
5 13 506.12 18 15.22 1050 288 3.44 / 93.35 2 3
6 8 0.00 165 15.32 329 832 4.28 / 94.19 2 4
Average= 4.28
(KJ/cycle)

Cycle 20 GMT 7/ 5/2023 3:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 38 15.25 487 282 0.28 / 85.68 2 2
2 7 2008.44 38 14.85 3009 1698 1.98 / 87.37 2 2
3 13 1562.16 18 14.95 2434 655 2.64 / 88.03 2 2
4 13 1083.00 18 15.06 1782 483 3.12 / 88.51 2 3
5 13 628.92 18 15.18 1171 320 3.44 / 88.83 2 3
6 13 45.88 18 15.35 364 101 3.54 / 88.93 2 3
7 8 0.24 165 15.30 326 823 4.36 / 89.76 2 5
8 14 0.24 30 15.28 335 154 4.52 / 89.91 2 8
Average= 4.28
(KJ/cycle)

Cycle 19 GMT 27/ 4/2023 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 38 15.28 491 285 0.29 / 81.06 2 2
2 7 2019.04 38 14.86 3013 1701 1.99 / 82.77 2 2
3 13 1739.96 18 14.92 2656 713 2.70 / 83.48 2 2
4 13 1182.64 18 15.04 1923 521 3.22 / 84.00 2 3
5 13 575.92 18 15.20 1100 301 3.52 / 84.30 2 3
6 13 39.52 18 15.35 400 111 3.63 / 84.41 2 3
7 8 0.12 165 15.31 330 834 4.47 / 85.25 2 6
8 14 0.12 30 15.28 325 149 4.61 / 85.39 2 7
Average= 4.27
(KJ/cycle)

Cycle 18 GMT 17/ 4/2023 14:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 38 15.25 494 286 0.29 / 76.57 2 2
2 7 2022.96 38 14.86 3026 1709 1.99 / 78.28 2 2
3 13 1648.08 18 14.96 2540 684 2.68 / 78.97 2 2
4 13 1142.44 18 15.06 1874 508 3.19 / 79.47 2 3
5 13 489.96 18 15.25 980 269 3.46 / 79.74 2 3
6 13 60.12 18 15.37 385 107 3.56 / 79.85 2 3
7 8 0.08 165 15.33 307 777 4.34 / 80.63 2 7
8 14 0.08 30 15.30 334 153 4.49 / 80.78 3 5
Average= 4.25
(KJ/cycle)

Cycle 17 GMT 7/ 4/2023 19:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 38 15.26 475 275 0.28 / 72.14 2 2
2 7 2023.48 39 14.86 3026 1754 2.03 / 73.89 2 2
3 13 1601.48 18 14.96 2485 669 2.70 / 74.56 2 2
4 13 1115.96 18 15.05 1861 504 3.20 / 75.07 2 3
5 13 469.52 18 15.23 986 270 3.47 / 75.34 2 3
6 13 41.24 18 15.35 410 113 3.59 / 75.45 2 3
7 8 0.00 165 15.31 331 836 4.42 / 76.29 2 5
Average= 4.24
(KJ/cycle)

Cycle 16 GMT 29/ 3/2023 1:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 38 15.27 500 290 0.29 / 67.86 2 2
2 7 2007.00 38 14.87 2990 1690 1.98 / 69.55 2 2
3 13 1642.96 18 14.94 2547 685 2.66 / 70.24 2 2
4 13 1100.24 18 15.06 1818 493 3.16 / 70.73 2 3
5 13 468.32 18 15.25 949 261 3.42 / 70.99 2 3
6 13 37.08 18 15.37 352 97 3.52 / 71.09 2 3
7 8 0.16 165 15.32 308 779 4.29 / 71.87 2 7
Average= 4.23
(KJ/cycle)

Cycle 15 GMT 19/ 3/2023 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 38 15.27 489 284 0.28 / 63.43 2 2
2 7 2022.12 38 14.88 3016 1705 1.99 / 65.14 2 2
3 13 1701.44 18 14.95 2599 699 2.69 / 65.84 2 2
4 13 1153.44 18 15.06 1880 510 3.20 / 66.35 2 3
5 13 520.40 18 15.24 1024 281 3.48 / 66.63 2 3
6 13 46.92 18 15.38 373 103 3.58 / 66.73 2 3
7 8 0.08 165 15.33 332 840 4.42 / 67.57 2 5
Average= 4.22
(KJ/cycle)

Cycle 14 GMT 9/ 3/2023 12: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 38 15.28 487 283 0.28 / 59.18 2 2
2 7 2007.16 38 14.87 3006 1699 1.98 / 60.87 2 2
3 13 1590.36 18 14.97 2465 664 2.65 / 61.54 2 2
4 13 1155.28 18 15.05 1895 513 3.16 / 62.05 2 3
5 13 502.76 18 15.23 1001 274 3.43 / 62.33 2 3
6 13 37.36 18 15.37 350 97 3.53 / 62.42 2 3
7 8 0.16 165 15.34 287 726 4.26 / 63.15 2 5
Average= 4.21
(KJ/cycle)

Cycle 13 GMT 27/ 2/2023 17:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 38 15.28 491 285 0.29 / 54.96 2 2
2 7 2021.08 38 14.85 3014 1701 1.99 / 56.66 2 2
3 13 1591.64 18 14.96 2461 663 2.65 / 57.32 2 2
4 13 1071.84 18 15.08 1776 482 3.13 / 57.80 2 3
5 13 479.92 18 15.25 967 265 3.40 / 58.07 2 3
6 13 23.56 18 15.39 333 92 3.49 / 58.16 2 3
7 8 -0.04 165 15.35 289 732 4.22 / 58.89 2 4
Average= 4.21
(KJ/cycle)

Cycle 12 GMT 17/ 2/2023 22:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 37 15.28 503 284 0.28 / 50.69 2 2
2 3 1017.92 1 15.33 1829 28 0.31 / 50.71 2 2
3 7 2008.36 38 14.87 2997 1693 2.01 / 52.41 2 2
4 13 1602.16 18 14.98 2491 672 2.68 / 53.08 2 2
5 13 1110.24 18 15.07 1816 493 3.17 / 53.57 2 3
6 13 477.68 18 15.26 969 266 3.44 / 53.84 2 3
7 13 39.84 18 15.39 354 98 3.53 / 53.94 2 3
8 8 0.12 165 15.35 291 737 4.27 / 54.67 2 6
Average= 4.21
(KJ/cycle)

Cycle 11 GMT 8/ 2/2023 4: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 37 15.29 478 270 0.27 / 46.26 2 2
2 7 2021.00 38 14.89 3009 1703 1.97 / 47.97 2 2
3 13 1729.76 18 14.96 2659 716 2.69 / 48.68 2 2
4 13 1120.60 18 15.09 1855 504 3.19 / 49.19 2 3
5 13 445.52 18 15.27 949 261 3.45 / 49.45 2 3
6 13 30.64 18 15.39 388 107 3.56 / 49.56 2 3
7 8 0.16 165 15.34 334 845 4.41 / 50.40 2 6
Average= 4.20
(KJ/cycle)

Cycle 10 GMT 29/ 1/2023 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.40 37 15.30 501 284 0.28 / 41.51 2 2
2 7 2006.60 74 14.77 2984 3261 3.55 / 44.77 2 2
3 13 763.84 18 15.18 1364 373 3.92 / 45.15 2 3
4 13 74.40 18 15.39 407 113 4.03 / 45.26 2 3
5 8 0.08 165 15.36 290 735 4.77 / 45.99 2 6
Average= 4.18
(KJ/cycle)

Cycle 9 GMT 19/ 1/2023 13: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 37 15.31 452 256 0.26 / 36.77 2 2
2 7 2021.04 74 14.77 3001 3280 3.54 / 40.05 2 2
3 13 645.24 18 15.22 1199 328 3.86 / 40.37 2 3
4 13 90.28 18 15.38 431 119 3.98 / 40.49 2 3
5 8 0.20 165 15.36 290 735 4.72 / 41.23 2 7
Average= 4.12
(KJ/cycle)

Cycle 8 GMT 9/ 1/2023 16:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 37 15.29 510 289 0.29 / 32.01 2 2
2 3 1024.08 1 15.32 1793 27 0.32 / 32.04 2 2
3 7 2005.48 74 14.78 2988 3268 3.58 / 35.30 2 2
4 13 751.96 18 15.19 1346 368 3.95 / 35.67 2 3
5 13 69.96 18 15.39 398 110 4.06 / 35.78 2 3
6 8 0.04 165 15.36 287 727 4.79 / 36.51 2 5
Average= 4.06
(KJ/cycle)

Cycle 7 GMT 30/12/2022 19:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 35 15.29 504 270 0.27 / 27.00 2 2
2 10 1033.80 2 15.25 1819 55 0.33 / 27.05 2 2
3 7 2019.08 74 14.77 3006 3285 3.61 / 30.34 2 2
4 13 764.92 18 15.17 1410 385 4.00 / 30.72 2 3
5 13 80.92 18 15.37 467 129 4.12 / 30.85 2 3
6 8 0.24 165 15.35 342 866 4.99 / 31.72 2 5
Average= 3.97
(KJ/cycle)

Cycle 6 GMT 20/12/2022 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 29 15.32 500 222 0.22 / 21.97 2 2
2 10 1041.44 4 15.24 1791 109 0.33 / 22.08 2 2
3 10 1077.80 2 15.24 1869 57 0.39 / 22.14 2 2
4 3 1055.84 2 15.29 1829 56 0.44 / 22.20 2 2
5 7 2013.48 74 14.78 2994 3275 3.72 / 25.47 2 2
6 13 507.24 18 15.25 1045 287 4.01 / 25.76 2 3
7 13 47.56 18 15.38 414 115 4.12 / 25.87 2 3
8 8 -0.04 165 15.34 339 858 4.98 / 26.73 2 6
Average= 3.82
(KJ/cycle)

Cycle 5 GMT 11/12/2022 2:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 29 15.31 492 218 0.22 / 17.30 2 2
2 7 2009.92 74 14.79 2996 3279 3.50 / 20.58 2 2
3 13 615.00 18 15.25 1153 316 3.81 / 20.89 2 3
4 13 73.84 18 15.40 400 111 3.92 / 21.01 2 3
5 8 0.20 165 15.37 294 746 4.67 / 21.75 2 7
Average= 3.63
(KJ/cycle)

Cycle 4 GMT 1/12/2022 5:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 28 15.31 496 213 0.21 / 13.45 2 2
2 3 1019.92 1 15.34 1777 27 0.24 / 13.48 2 2
3 7 1507.68 74 14.97 2358 2612 2.85 / 16.09 2 2
4 13 131.08 18 15.38 536 148 3.00 / 16.24 2 3
5 8 0.12 165 15.36 333 844 3.84 / 17.08 2 6
Average= 3.42
(KJ/cycle)

Cycle 3 GMT 30/11/2022 6: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 15.29 490 210 0.21 / 9.56 2 2
2 10 1006.56 2 15.26 1759 54 0.26 / 9.61 2 2
3 3 967.20 -1 15.66 1 0 0.05 / 9.61 2 2
4 7 1507.96 74 14.97 2356 2610 2.87 / 12.22 2 2
5 13 135.20 18 15.38 543 150 3.02 / 12.37 2 3
6 8 0.00 165 15.36 340 862 3.89 / 13.24 2 5
Average= 3.31
(KJ/cycle)

Cycle 2 GMT 29/11/2022 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 15.32 478 227 0.23 / 5.34 2 2
2 3 852.72 -3 15.68 1 0 0.00 / 5.34 2 2
3 7 1521.32 75 14.97 2346 2634 2.86 / 7.97 2 3
4 13 122.52 18 15.37 506 140 3.00 / 8.11 2 3
5 8 0.12 165 15.36 337 854 3.86 / 8.97 2 7
6 14 0.12 75 15.31 334 384 4.24 / 9.35 2 9
Average= 3.12
(KJ/cycle)

Cycle 1 GMT 28/11/2022 7: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 26 15.48 444 179 0.18 / 2.02 2 2
2 3 1028.24 1 15.33 1769 27 0.21 / 2.05 2 2
3 7 1002.52 74 15.14 1678 1880 2.09 / 3.93 2 3
4 8 0.08 165 15.39 321 815 2.90 / 4.75 2 10
5 14 0.08 75 15.35 318 366 3.27 / 5.11 2 8
Average= 2.56
(KJ/cycle)

Cycle 0 GMT 27/11/2022 20:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 90.48 26 15.64 437 178 0.18 / 0.18 2 2
2 7 105.80 74 15.60 448 517 0.69 / 0.69 2 2
3 8 0.16 240 15.56 308 1150 1.85 / 1.85 2 11
Average= 1.85
(KJ/cycle)