SIO Argo Site:
Pump Diagnostics Page   



Serial= 3104 WMO= 5906768

Return

←PreviousNext→

Cycle 35 GMT 25/ 9/2023 5:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 28 15.24 475 203 0.20 / 136.47 2 2
2 3 1038.32 1 15.23 1761 27 0.23 / 136.50 2 3
3 7 2004.48 74 14.67 2897 3145 3.37 / 139.64 2 3
4 13 377.04 18 15.23 811 222 3.60 / 139.86 2 2
5 8 0.24 165 15.29 294 742 4.34 / 140.61 2 3
Average= 3.91 (KJ/cycle)

Cycle 34 GMT 15/ 9/2023 8:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 28 15.24 474 202 0.20 / 132.10 2 2
2 7 2010.88 74 14.66 2914 3161 3.36 / 135.26 2 3
3 13 392.16 18 15.20 858 235 3.60 / 135.50 2 2
4 8 -0.04 165 15.27 306 771 4.37 / 136.27 2 3
Average= 3.89 (KJ/cycle)

Cycle 33 GMT 5/ 9/2023 11:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 28 15.26 466 199 0.20 / 127.76 2 2
2 7 2003.40 75 14.65 2889 3174 3.37 / 130.93 2 3
3 13 362.48 18 15.22 784 215 3.59 / 131.14 2 2
4 8 0.28 165 15.28 299 754 4.34 / 131.90 2 3
Average= 3.88 (KJ/cycle)

Cycle 32 GMT 26/ 8/2023 14:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 28 15.26 472 202 0.20 / 123.42 2 2
2 3 1018.64 1 15.28 1714 26 0.23 / 123.45 2 5
3 7 2011.32 74 14.65 2902 3146 3.37 / 126.60 2 4
4 13 393.80 18 15.22 821 225 3.60 / 126.82 2 2
5 8 0.28 165 15.29 292 737 4.34 / 127.56 2 3
Average= 3.87 (KJ/cycle)

Cycle 31 GMT 16/ 8/2023 17:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 27 15.26 474 195 0.20 / 119.04 2 2
2 10 1035.00 2 15.19 1774 54 0.25 / 119.09 2 3
3 7 2009.32 74 14.66 2907 3154 3.40 / 122.25 2 5
4 13 384.96 18 15.24 814 223 3.63 / 122.47 2 2
5 8 -0.04 165 15.29 297 749 4.38 / 123.22 2 3
Average= 3.85 (KJ/cycle)

Cycle 30 GMT 6/ 8/2023 20:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 15.22 457 195 0.19 / 114.68 2 2
2 3 959.64 -1 15.61 0 0 0.00 / 114.68 2 2
3 7 2007.52 74 14.68 2912 3163 3.36 / 117.84 2 5
4 13 393.56 18 15.25 830 228 3.59 / 118.07 2 2
5 8 0.12 165 15.30 307 775 4.36 / 118.85 2 3
Average= 3.83 (KJ/cycle)

Cycle 29 GMT 27/ 7/2023 23:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 27 15.26 459 189 0.19 / 109.91 2 2
2 3 1044.36 1 15.24 1761 27 0.22 / 109.94 2 3
3 7 2004.84 74 14.65 2895 3138 3.35 / 113.08 2 4
4 13 394.08 18 15.23 825 226 3.58 / 113.30 2 3
5 13 17.24 18 15.33 299 83 3.66 / 113.39 2 2
6 8 -0.08 165 15.28 301 759 4.42 / 114.14 2 6
7 14 -0.08 75 15.25 298 341 4.76 / 114.48 2 3
Average= 3.82 (KJ/cycle)

Cycle 28 GMT 18/ 7/2023 2:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 15.26 460 197 0.20 / 105.62 2 2
2 3 960.12 -1 15.62 0 0 0.00 / 105.62 2 2
3 7 2003.64 74 14.66 2901 3147 3.34 / 108.76 2 5
4 13 382.40 18 15.23 812 223 3.57 / 108.99 2 3
5 8 0.12 165 15.31 291 735 4.30 / 109.72 2 3
Average= 3.78 (KJ/cycle)

Cycle 27 GMT 8/ 7/2023 5:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 26 15.26 458 182 0.18 / 101.40 2 2
2 10 1016.00 2 15.20 1739 53 0.23 / 101.45 2 3
3 7 1589.48 74 14.84 2409 2645 2.88 / 104.10 2 3
4 13 329.52 18 15.29 746 205 3.09 / 104.30 2 2
5 8 0.12 165 15.32 307 776 3.86 / 105.08 2 2
6 14 0.12 75 15.29 298 342 4.20 / 105.42 2 3
Average= 3.77 (KJ/cycle)

Cycle 26 GMT 28/ 6/2023 6:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 28 15.26 469 200 0.20 / 97.07 2 2
2 3 926.24 -1 15.62 0 0 0.00 / 97.07 2 2
3 7 2010.44 74 14.68 2908 3159 3.36 / 100.23 2 3
4 13 379.60 18 15.24 811 222 3.58 / 100.45 2 3
5 8 -0.28 165 15.30 304 767 4.35 / 101.22 2 3
Average= 3.75 (KJ/cycle)

Cycle 25 GMT 18/ 6/2023 9:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 26 15.25 468 186 0.19 / 92.65 2 2
2 10 1038.92 2 15.18 1755 53 0.24 / 92.71 2 3
3 7 1780.64 74 14.75 2646 2888 3.13 / 95.60 2 3
4 13 358.28 18 15.27 782 215 3.34 / 95.81 2 3
5 8 0.08 165 15.32 283 715 4.06 / 96.53 2 2
6 14 0.08 75 15.28 299 343 4.40 / 96.87 2 3
Average= 3.73 (KJ/cycle)

Cycle 24 GMT 8/ 6/2023 9:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 26 15.29 459 182 0.18 / 88.47 2 2
2 3 1019.60 1 15.29 1738 27 0.21 / 88.49 2 3
3 7 1913.24 74 14.69 2807 3051 3.26 / 91.55 2 4
4 13 338.48 18 15.26 757 208 3.47 / 91.75 2 2
5 8 0.12 165 15.31 283 715 4.18 / 92.47 2 3
Average= 3.70 (KJ/cycle)

Cycle 23 GMT 29/ 5/2023 9:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 15.34 472 203 0.20 / 84.93 2 2
2 3 960.48 -1 15.63 0 0 0.00 / 84.93 2 2
3 7 1186.96 74 15.06 1913 2132 2.33 / 87.06 2 3
4 13 70.40 18 15.38 415 115 2.45 / 87.18 2 2
5 8 0.16 165 15.35 302 765 3.21 / 87.94 2 3
6 14 0.16 75 15.32 298 342 3.56 / 88.28 2 4
Average= 3.68 (KJ/cycle)

Cycle 22 GMT 19/ 5/2023 11: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 15.33 462 198 0.20 / 82.02 2 2
2 7 978.48 74 15.18 1629 1830 2.03 / 83.85 2 4
3 13 37.52 18 15.42 362 100 2.13 / 83.95 2 2
4 8 0.08 165 15.39 306 777 2.91 / 84.73 2 4
Average= 3.68 (KJ/cycle)

Cycle 21 GMT 9/ 5/2023 12:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 28 15.32 473 203 0.20 / 78.76 2 2
2 3 973.12 -1 15.64 0 0 0.00 / 78.76 2 2
3 3 1024.60 1 15.31 1756 27 0.23 / 78.78 2 3
4 7 1199.96 74 15.06 1929 2150 2.38 / 80.93 2 3
5 13 91.12 18 15.39 446 124 2.50 / 81.06 2 2
6 8 -0.16 165 15.37 302 766 3.27 / 81.82 2 2
Average= 3.72 (KJ/cycle)

Cycle 20 GMT 29/ 4/2023 13:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 27 15.26 480 198 0.20 / 75.35 2 2
2 10 1000.84 2 15.21 1700 52 0.25 / 75.40 2 3
3 7 1310.84 74 15.00 2043 2268 2.52 / 77.67 2 3
4 13 58.80 18 15.40 396 110 2.63 / 77.78 2 2
5 8 0.12 165 15.36 305 773 3.40 / 78.55 2 3
Average= 3.74 (KJ/cycle)

Cycle 19 GMT 19/ 4/2023 15:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 28 15.27 461 197 0.20 / 71.09 2 2
2 3 966.48 -1 15.63 0 0 0.00 / 71.09 2 2
3 7 2001.88 74 14.66 2908 3155 3.35 / 74.25 2 3
4 13 387.52 18 15.24 825 226 3.58 / 74.48 2 2
5 8 0.24 165 15.32 268 677 4.26 / 75.15 2 2
Average= 3.76 (KJ/cycle)

Cycle 18 GMT 9/ 4/2023 16:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 27 15.28 462 191 0.19 / 66.55 2 2
2 3 1034.40 1 15.27 1777 27 0.22 / 66.58 2 3
3 7 2003.08 74 14.70 2895 3149 3.37 / 69.73 2 3
4 13 231.12 18 15.32 608 168 3.53 / 69.89 2 2
5 8 -0.16 165 15.34 265 671 4.21 / 70.57 2 4
6 14 -0.16 75 15.30 290 333 4.54 / 70.90 2 4
Average= 3.73 (KJ/cycle)

Cycle 17 GMT 30/ 3/2023 19: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 28 15.27 467 200 0.20 / 62.24 2 2
2 7 2002.56 74 14.70 2903 3158 3.36 / 65.39 2 3
3 13 369.92 18 15.28 802 221 3.58 / 65.61 2 3
4 8 0.16 165 15.33 295 746 4.32 / 66.36 2 3
Average= 3.69 (KJ/cycle)

Cycle 16 GMT 20/ 3/2023 21:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 28 15.32 461 198 0.20 / 57.60 2 2
2 7 2009.52 74 14.73 2915 3177 3.38 / 60.77 2 4
3 13 354.28 18 15.29 778 214 3.59 / 60.99 2 2
4 8 0.12 165 15.33 276 698 4.29 / 61.69 2 2
5 14 0.12 75 15.30 305 350 4.64 / 62.04 2 4
Average= 3.65 (KJ/cycle)

Cycle 15 GMT 11/ 3/2023 0:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 28 15.29 471 202 0.20 / 53.97 2 2
2 7 1494.24 75 14.93 2285 2559 2.76 / 56.53 2 4
3 13 115.00 18 15.38 451 125 2.89 / 56.65 2 2
4 8 0.12 165 15.37 295 748 3.63 / 57.40 2 3
Average= 3.59 (KJ/cycle)

Cycle 14 GMT 1/ 3/2023 1:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 28 15.31 461 198 0.20 / 49.58 2 2
2 7 2011.16 74 14.72 2917 3177 3.38 / 52.76 2 3
3 13 398.96 18 15.27 840 231 3.61 / 52.99 2 3
4 13 19.48 18 15.38 303 84 3.69 / 53.07 2 2
5 8 -0.04 165 15.34 274 694 4.38 / 53.76 2 3
Average= 3.58 (KJ/cycle)

Cycle 13 GMT 19/ 2/2023 4:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 28 15.33 463 199 0.20 / 45.87 2 2
2 7 1582.44 74 14.89 2396 2640 2.84 / 48.51 2 4
3 13 94.44 18 15.39 421 117 2.96 / 48.62 2 2
4 8 0.20 165 15.37 299 758 3.71 / 49.38 2 4
Average= 3.53 (KJ/cycle)

Cycle 12 GMT 9/ 2/2023 5:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 28 15.33 472 203 0.20 / 42.16 2 2
2 7 1576.04 75 14.89 2385 2663 2.87 / 44.82 2 3
3 13 91.60 18 15.39 417 116 2.98 / 44.94 2 2
4 8 -0.04 165 15.37 287 728 3.71 / 45.67 2 3
Average= 3.51 (KJ/cycle)

Cycle 11 GMT 30/ 1/2023 5:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 28 15.31 434 186 0.19 / 38.78 2 2
2 3 1017.60 1 15.34 1724 26 0.21 / 38.80 2 3
3 7 1293.24 74 15.04 2044 2275 2.49 / 41.08 2 3
4 13 59.44 18 15.42 395 110 2.60 / 41.19 2 2
5 8 0.12 165 15.38 303 769 3.37 / 41.96 2 3
Average= 3.50 (KJ/cycle)

Cycle 10 GMT 20/ 1/2023 6:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 28 15.31 420 180 0.18 / 34.72 2 2
2 7 1787.20 74 14.79 2651 2901 3.08 / 37.62 2 3
3 13 325.16 18 15.31 740 204 3.29 / 37.82 2 2
4 13 24.40 18 15.38 312 86 3.37 / 37.91 2 2
5 8 -0.08 165 15.35 269 681 4.05 / 38.59 2 3
Average= 3.51 (KJ/cycle)

Cycle 9 GMT 10/ 1/2023 7:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 27 15.30 426 176 0.18 / 30.48 2 2
2 7 2004.40 74 14.73 2907 3169 3.34 / 33.65 2 3
3 13 349.88 18 15.29 774 213 3.56 / 33.86 2 3
4 8 -0.12 165 15.35 268 679 4.24 / 34.54 2 3
Average= 3.45 (KJ/cycle)

Cycle 8 GMT 31/12/2022 10:14:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 26 15.30 434 173 0.17 / 26.16 2 2
2 10 1004.48 2 15.23 1689 51 0.22 / 26.21 2 3
3 3 972.64 -1 15.63 0 0 0.05 / 26.21 2 3
4 3 1025.52 1 15.32 1763 27 0.25 / 26.24 2 2
5 7 2007.80 74 14.71 2908 3165 3.42 / 29.40 2 2
6 13 341.92 18 15.28 766 211 3.63 / 29.61 2 2
7 8 0.24 165 15.33 272 688 4.32 / 30.30 2 3
Average= 3.37 (KJ/cycle)

Cycle 7 GMT 21/12/2022 13:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 26 15.34 445 177 0.18 / 21.97 2 2
2 7 2005.36 74 14.72 2904 3163 3.34 / 25.13 2 3
3 13 235.36 18 15.32 612 169 3.51 / 25.30 2 3
4 8 0.12 165 15.35 272 689 4.20 / 25.99 2 3
Average= 3.25 (KJ/cycle)

Cycle 6 GMT 11/12/2022 15:59: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 26 15.36 427 171 0.17 / 18.48 2 2
2 7 1470.88 74 14.96 2260 2502 2.67 / 20.98 2 4
3 13 96.84 18 15.40 423 117 2.79 / 21.10 2 2
4 8 0.12 165 15.39 273 693 3.48 / 21.79 2 3
Average= 3.11 (KJ/cycle)

Cycle 5 GMT 1/12/2022 16:55:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 29 15.31 428 190 0.19 / 15.39 2 2
2 3 882.80 -2 15.66 0 0 0.00 / 15.39 2 2
3 7 1211.68 74 15.09 1909 2132 2.32 / 17.52 2 3
4 13 32.88 18 15.45 320 89 2.41 / 17.61 2 2
5 8 0.00 165 15.41 274 697 3.11 / 18.31 2 5
Average= 3.05 (KJ/cycle)

Cycle 4 GMT 21/11/2022 18:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 25 15.32 428 164 0.16 / 11.88 2 2
2 7 1507.48 74 14.96 2287 2532 2.70 / 14.41 2 3
3 13 54.24 18 15.39 350 97 2.79 / 14.51 2 2
4 8 0.04 165 15.36 272 689 3.48 / 15.20 2 3
Average= 3.04 (KJ/cycle)

Cycle 3 GMT 20/11/2022 18:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 24 15.32 421 155 0.15 / 8.35 2 2
2 3 1038.68 1 15.30 1768 27 0.18 / 8.38 2 3
3 7 1525.40 74 14.95 2309 2554 2.74 / 10.93 2 3
4 13 62.04 18 15.39 362 100 2.84 / 11.03 2 2
5 8 0.04 165 15.36 269 682 3.52 / 11.72 2 4
Average= 2.93 (KJ/cycle)

Cycle 2 GMT 19/11/2022 19:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 31 15.30 434 206 0.21 / 4.84 2 2
2 3 708.76 -6 15.65 0 0 0.00 / 4.84 2 2
3 7 1510.72 74 14.94 2294 2536 2.74 / 7.38 2 3
4 13 105.92 18 15.37 433 120 2.86 / 7.50 2 2
5 8 0.04 165 15.36 277 702 3.56 / 8.20 2 4
Average= 2.73 (KJ/cycle)

Cycle 1 GMT 18/11/2022 19:55:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 26 15.47 394 158 0.16 / 1.74 2 3
2 3 933.92 -1 15.66 0 0 0.00 / 1.74 2 3
3 7 1008.80 74 15.13 1641 1837 2.00 / 3.57 2 4
4 8 -0.04 165 15.38 288 731 2.73 / 4.30 2 3
5 14 -0.04 75 15.34 287 330 3.06 / 4.63 2 3
Average= 2.32 (KJ/cycle)

Cycle 0 GMT 18/11/2022 9:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 26 15.62 392 159 0.16 / 0.16 3 3
2 7 123.44 74 15.57 409 471 0.63 / 0.63 2 3
3 8 0.24 240 15.54 254 947 1.58 / 1.58 2 9
Average= 1.58 (KJ/cycle)