SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 26 | 15.03 | 482 | 188 | 0.19 / 505.37 | 2 | 2 |
2 | 3 | 972.52 | -1 | 15.39 | 0 | 0 | 0.00 / 505.37 | 2 | 2 |
3 | 7 | 1876.20 | 32 | 14.75 | 2697 | 1273 | 1.46 / 506.64 | 2 | 3 |
4 | 13 | 1506.24 | 18 | 14.78 | 2270 | 604 | 2.07 / 507.25 | 2 | 3 |
5 | 13 | 1006.60 | 18 | 14.86 | 1648 | 441 | 2.51 / 507.69 | 2 | 3 |
6 | 13 | 492.92 | 18 | 14.98 | 1003 | 270 | 2.78 / 507.96 | 2 | 4 |
7 | 13 | 57.00 | 18 | 15.10 | 415 | 113 | 2.89 / 508.07 | 2 | 4 |
8 | 8 | 0.12 | 165 | 15.06 | 327 | 813 | 3.70 / 508.88 | 2 | 9 |
Average= | 2.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 26 | 15.03 | 491 | 192 | 0.19 / 501.50 | 2 | 2 |
2 | 7 | 1877.44 | 32 | 14.75 | 2711 | 1280 | 1.47 / 502.78 | 2 | 3 |
3 | 13 | 1519.20 | 18 | 14.77 | 2295 | 610 | 2.08 / 503.39 | 2 | 3 |
4 | 13 | 920.28 | 18 | 14.87 | 1549 | 415 | 2.50 / 503.81 | 2 | 3 |
5 | 13 | 540.88 | 18 | 14.96 | 1075 | 289 | 2.79 / 504.10 | 2 | 4 |
6 | 13 | 89.16 | 18 | 15.09 | 453 | 123 | 2.91 / 504.22 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.06 | 328 | 815 | 3.72 / 505.04 | 2 | 6 |
8 | 14 | 0.12 | 30 | 15.03 | 326 | 147 | 3.87 / 505.18 | 2 | 9 |
Average= | 2.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 26 | 15.02 | 487 | 190 | 0.19 / 497.80 | 2 | 2 |
2 | 7 | 1873.20 | 32 | 14.76 | 2702 | 1276 | 1.47 / 499.08 | 2 | 3 |
3 | 13 | 1488.40 | 18 | 14.78 | 2255 | 600 | 2.07 / 499.68 | 2 | 3 |
4 | 13 | 927.12 | 18 | 14.87 | 1564 | 419 | 2.48 / 500.09 | 2 | 4 |
5 | 13 | 497.32 | 18 | 14.98 | 999 | 269 | 2.75 / 500.36 | 2 | 4 |
6 | 13 | 56.08 | 18 | 15.09 | 420 | 114 | 2.87 / 500.48 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.06 | 336 | 835 | 3.70 / 501.31 | 2 | 8 |
Average= | 2.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 26 | 15.03 | 480 | 188 | 0.19 / 494.10 | 2 | 2 |
2 | 7 | 1876.40 | 32 | 14.74 | 2701 | 1274 | 1.46 / 495.37 | 2 | 3 |
3 | 13 | 1457.36 | 18 | 14.78 | 2235 | 595 | 2.06 / 495.97 | 2 | 3 |
4 | 13 | 926.12 | 18 | 14.86 | 1561 | 418 | 2.47 / 496.39 | 2 | 4 |
5 | 13 | 589.92 | 18 | 14.94 | 1133 | 305 | 2.78 / 496.69 | 2 | 4 |
6 | 13 | 43.68 | 18 | 15.10 | 397 | 108 | 2.89 / 496.80 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.06 | 326 | 810 | 3.70 / 497.61 | 2 | 8 |
Average= | 2.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 26 | 15.03 | 481 | 188 | 0.19 / 490.24 | 2 | 2 |
2 | 7 | 1873.60 | 32 | 14.75 | 2699 | 1274 | 1.46 / 491.52 | 2 | 3 |
3 | 13 | 1451.72 | 18 | 14.79 | 2231 | 594 | 2.06 / 492.11 | 2 | 3 |
4 | 13 | 951.92 | 18 | 14.87 | 1598 | 428 | 2.48 / 492.54 | 2 | 3 |
5 | 13 | 562.76 | 18 | 14.95 | 1097 | 295 | 2.78 / 492.84 | 2 | 4 |
6 | 13 | 59.52 | 18 | 15.10 | 417 | 113 | 2.89 / 492.95 | 2 | 4 |
7 | 8 | 0.24 | 165 | 15.06 | 329 | 818 | 3.71 / 493.77 | 2 | 5 |
8 | 14 | 0.24 | 30 | 15.04 | 324 | 146 | 3.86 / 493.91 | 2 | 10 |
Average= | 2.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 26 | 15.04 | 460 | 180 | 0.18 / 486.54 | 2 | 2 |
2 | 3 | 980.24 | -1 | 15.43 | 0 | 0 | 0.00 / 486.54 | 2 | 2 |
3 | 7 | 1871.56 | 32 | 14.77 | 2685 | 1269 | 1.45 / 487.81 | 2 | 3 |
4 | 13 | 1493.32 | 18 | 14.79 | 2252 | 600 | 2.05 / 488.41 | 2 | 3 |
5 | 13 | 995.84 | 18 | 14.86 | 1640 | 439 | 2.49 / 488.85 | 2 | 4 |
6 | 13 | 544.36 | 18 | 14.96 | 1087 | 293 | 2.78 / 489.14 | 2 | 4 |
7 | 13 | 85.68 | 18 | 15.09 | 437 | 119 | 2.90 / 489.26 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.06 | 322 | 800 | 3.70 / 490.06 | 2 | 7 |
Average= | 2.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 26 | 15.04 | 456 | 178 | 0.18 / 482.85 | 2 | 3 |
2 | 7 | 1877.28 | 32 | 14.75 | 2695 | 1272 | 1.45 / 484.13 | 2 | 3 |
3 | 13 | 1513.44 | 18 | 14.78 | 2282 | 607 | 2.06 / 484.73 | 2 | 3 |
4 | 13 | 928.92 | 18 | 14.87 | 1553 | 416 | 2.47 / 485.15 | 2 | 4 |
5 | 13 | 644.08 | 18 | 14.93 | 1196 | 321 | 2.79 / 485.47 | 2 | 4 |
6 | 13 | 63.84 | 18 | 15.11 | 408 | 111 | 2.91 / 485.58 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.06 | 313 | 778 | 3.68 / 486.36 | 2 | 10 |
Average= | 2.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 26 | 15.03 | 468 | 183 | 0.18 / 479.20 | 2 | 2 |
2 | 3 | 1017.32 | 1 | 15.07 | 1711 | 26 | 0.21 / 479.22 | 2 | 3 |
3 | 7 | 1871.36 | 32 | 14.75 | 2691 | 1270 | 1.48 / 480.49 | 2 | 3 |
4 | 13 | 1500.16 | 18 | 14.79 | 2265 | 603 | 2.08 / 481.10 | 2 | 3 |
5 | 13 | 847.56 | 18 | 14.89 | 1457 | 391 | 2.47 / 481.49 | 2 | 4 |
6 | 13 | 526.08 | 18 | 14.96 | 1036 | 279 | 2.75 / 481.77 | 2 | 4 |
7 | 13 | 45.12 | 18 | 15.10 | 387 | 105 | 2.86 / 481.87 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.05 | 324 | 805 | 3.66 / 482.67 | 2 | 9 |
Average= | 2.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 26 | 15.03 | 461 | 180 | 0.18 / 475.53 | 2 | 2 |
2 | 7 | 1876.20 | 32 | 14.76 | 2695 | 1273 | 1.45 / 476.80 | 2 | 3 |
3 | 13 | 1504.68 | 18 | 14.78 | 2271 | 604 | 2.06 / 477.40 | 2 | 3 |
4 | 13 | 968.92 | 18 | 14.87 | 1603 | 429 | 2.49 / 477.83 | 2 | 4 |
5 | 13 | 523.16 | 18 | 14.97 | 1025 | 276 | 2.76 / 478.11 | 2 | 4 |
6 | 13 | 83.16 | 18 | 15.09 | 437 | 119 | 2.88 / 478.23 | 2 | 4 |
7 | 8 | 0.00 | 165 | 15.06 | 316 | 785 | 3.67 / 479.01 | 2 | 7 |
Average= | 2.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 26 | 15.04 | 455 | 178 | 0.18 / 471.90 | 2 | 2 |
2 | 3 | 1016.12 | 1 | 15.10 | 1710 | 26 | 0.20 / 471.93 | 2 | 2 |
3 | 7 | 1875.92 | 32 | 14.75 | 2687 | 1268 | 1.47 / 473.20 | 2 | 3 |
4 | 13 | 1358.48 | 18 | 14.81 | 2095 | 558 | 2.03 / 473.75 | 2 | 3 |
5 | 13 | 927.44 | 18 | 14.87 | 1557 | 417 | 2.45 / 474.17 | 2 | 3 |
6 | 13 | 542.48 | 18 | 14.96 | 1049 | 282 | 2.73 / 474.45 | 2 | 4 |
7 | 13 | 86.72 | 18 | 15.09 | 436 | 118 | 2.85 / 474.57 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.07 | 312 | 776 | 3.62 / 475.35 | 2 | 7 |
Average= | 2.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 26 | 15.04 | 468 | 183 | 0.18 / 468.24 | 2 | 2 |
2 | 7 | 1872.00 | 32 | 14.77 | 2684 | 1269 | 1.45 / 469.51 | 2 | 3 |
3 | 13 | 1502.12 | 18 | 14.79 | 2261 | 602 | 2.05 / 470.11 | 2 | 3 |
4 | 13 | 1008.32 | 18 | 14.86 | 1642 | 439 | 2.49 / 470.55 | 2 | 4 |
5 | 13 | 521.40 | 18 | 14.99 | 1021 | 275 | 2.77 / 470.83 | 2 | 4 |
6 | 13 | 78.16 | 18 | 15.09 | 421 | 114 | 2.88 / 470.94 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.07 | 314 | 781 | 3.66 / 471.72 | 2 | 7 |
Average= | 2.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 25 | 15.04 | 466 | 175 | 0.18 / 464.53 | 2 | 2 |
2 | 3 | 1021.72 | 1 | 15.07 | 1699 | 26 | 0.20 / 464.56 | 2 | 3 |
3 | 7 | 1877.84 | 32 | 14.77 | 2709 | 1280 | 1.48 / 465.84 | 2 | 3 |
4 | 13 | 1464.88 | 18 | 14.80 | 2230 | 594 | 2.08 / 466.43 | 2 | 3 |
5 | 13 | 964.72 | 18 | 14.87 | 1606 | 430 | 2.51 / 466.86 | 2 | 3 |
6 | 13 | 529.44 | 18 | 14.97 | 1050 | 283 | 2.79 / 467.15 | 2 | 4 |
7 | 13 | 83.88 | 18 | 15.10 | 442 | 120 | 2.91 / 467.27 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.07 | 319 | 793 | 3.70 / 468.06 | 2 | 6 |
Average= | 2.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 26 | 15.05 | 467 | 183 | 0.18 / 460.95 | 2 | 2 |
2 | 3 | 976.12 | -1 | 15.40 | 0 | 0 | 0.00 / 460.95 | 2 | 2 |
3 | 7 | 1875.24 | 32 | 14.76 | 2692 | 1271 | 1.45 / 462.22 | 2 | 3 |
4 | 13 | 1351.76 | 18 | 14.81 | 2093 | 558 | 2.01 / 462.78 | 2 | 3 |
5 | 13 | 875.60 | 18 | 14.89 | 1490 | 399 | 2.41 / 463.18 | 2 | 4 |
6 | 13 | 455.04 | 18 | 15.00 | 952 | 257 | 2.67 / 463.44 | 2 | 4 |
7 | 13 | 34.76 | 18 | 15.11 | 383 | 104 | 2.77 / 463.54 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.06 | 329 | 818 | 3.59 / 464.36 | 2 | 10 |
Average= | 2.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 25 | 15.04 | 491 | 185 | 0.18 / 457.21 | 2 | 2 |
2 | 7 | 1877.44 | 32 | 14.76 | 2706 | 1278 | 1.46 / 458.48 | 2 | 3 |
3 | 13 | 1508.80 | 18 | 14.78 | 2288 | 609 | 2.07 / 459.09 | 2 | 3 |
4 | 13 | 1028.76 | 18 | 14.85 | 1687 | 451 | 2.52 / 459.54 | 2 | 4 |
5 | 13 | 576.04 | 18 | 14.96 | 1116 | 301 | 2.82 / 459.84 | 2 | 4 |
6 | 13 | 66.04 | 18 | 15.11 | 421 | 115 | 2.94 / 459.96 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.06 | 326 | 810 | 3.75 / 460.77 | 2 | 6 |
Average= | 2.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 25 | 15.05 | 451 | 170 | 0.17 / 453.50 | 2 | 2 |
2 | 7 | 1873.40 | 32 | 14.77 | 2682 | 1268 | 1.44 / 454.77 | 2 | 3 |
3 | 13 | 1437.36 | 18 | 14.80 | 2194 | 584 | 2.02 / 455.35 | 2 | 3 |
4 | 13 | 942.08 | 18 | 14.88 | 1579 | 423 | 2.44 / 455.78 | 2 | 3 |
5 | 13 | 497.72 | 18 | 14.98 | 1007 | 272 | 2.72 / 456.05 | 2 | 4 |
6 | 13 | 46.28 | 18 | 15.11 | 412 | 112 | 2.83 / 456.16 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.06 | 347 | 862 | 3.69 / 457.02 | 2 | 6 |
Average= | 2.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 25 | 15.03 | 472 | 177 | 0.18 / 449.83 | 2 | 2 |
2 | 7 | 1874.96 | 33 | 14.77 | 2697 | 1315 | 1.49 / 451.15 | 2 | 3 |
3 | 13 | 1391.72 | 18 | 14.82 | 2129 | 568 | 2.06 / 451.72 | 2 | 3 |
4 | 13 | 963.88 | 18 | 14.88 | 1612 | 432 | 2.49 / 452.15 | 2 | 4 |
5 | 13 | 522.52 | 18 | 14.98 | 1040 | 280 | 2.77 / 452.43 | 2 | 4 |
6 | 13 | 37.64 | 18 | 15.12 | 375 | 102 | 2.87 / 452.53 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.07 | 322 | 801 | 3.67 / 453.33 | 2 | 8 |
Average= | 2.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 25 | 15.05 | 461 | 173 | 0.17 / 446.10 | 2 | 2 |
2 | 7 | 1876.12 | 32 | 14.75 | 2692 | 1271 | 1.44 / 447.37 | 2 | 3 |
3 | 13 | 1503.28 | 18 | 14.79 | 2262 | 602 | 2.05 / 447.98 | 2 | 3 |
4 | 13 | 1007.44 | 18 | 14.86 | 1659 | 444 | 2.49 / 448.42 | 2 | 3 |
5 | 13 | 559.32 | 18 | 14.96 | 1094 | 295 | 2.78 / 448.72 | 2 | 4 |
6 | 13 | 45.88 | 18 | 15.10 | 407 | 111 | 2.90 / 448.83 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.06 | 334 | 830 | 3.73 / 449.66 | 2 | 13 |
Average= | 2.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 24 | 15.03 | 462 | 167 | 0.17 / 442.43 | 2 | 2 |
2 | 3 | 1035.04 | 1 | 15.05 | 1740 | 26 | 0.19 / 442.45 | 2 | 2 |
3 | 7 | 1874.68 | 32 | 14.76 | 2686 | 1269 | 1.46 / 443.72 | 2 | 3 |
4 | 13 | 1549.88 | 18 | 14.77 | 2326 | 618 | 2.08 / 444.34 | 2 | 3 |
5 | 13 | 985.88 | 18 | 14.87 | 1624 | 435 | 2.51 / 444.77 | 2 | 3 |
6 | 13 | 498.52 | 18 | 14.98 | 992 | 267 | 2.78 / 445.04 | 2 | 4 |
7 | 13 | 47.48 | 18 | 15.11 | 381 | 104 | 2.89 / 445.14 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.08 | 316 | 786 | 3.67 / 445.93 | 2 | 9 |
Average= | 2.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 24 | 15.03 | 460 | 166 | 0.17 / 438.85 | 2 | 2 |
2 | 7 | 1872.44 | 32 | 14.76 | 2680 | 1266 | 1.43 / 440.11 | 2 | 3 |
3 | 13 | 1405.96 | 18 | 14.81 | 2151 | 573 | 2.01 / 440.69 | 2 | 3 |
4 | 13 | 933.40 | 18 | 14.87 | 1561 | 418 | 2.42 / 441.11 | 2 | 3 |
5 | 13 | 495.68 | 18 | 14.98 | 988 | 266 | 2.69 / 441.37 | 2 | 4 |
6 | 13 | 24.80 | 18 | 15.11 | 353 | 96 | 2.79 / 441.47 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.06 | 318 | 790 | 3.58 / 442.26 | 2 | 10 |
Average= | 2.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 24 | 15.04 | 477 | 172 | 0.17 / 435.18 | 2 | 2 |
2 | 7 | 1877.60 | 33 | 14.77 | 2704 | 1318 | 1.49 / 436.50 | 2 | 3 |
3 | 13 | 1459.76 | 18 | 14.80 | 2204 | 587 | 2.08 / 437.08 | 2 | 3 |
4 | 13 | 932.36 | 18 | 14.89 | 1550 | 415 | 2.49 / 437.50 | 2 | 4 |
5 | 13 | 548.44 | 18 | 14.98 | 1055 | 284 | 2.78 / 437.78 | 2 | 4 |
6 | 13 | 43.48 | 18 | 15.11 | 378 | 103 | 2.88 / 437.89 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.08 | 320 | 796 | 3.68 / 438.68 | 2 | 6 |
Average= | 2.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 24 | 15.05 | 479 | 173 | 0.17 / 431.51 | 2 | 2 |
2 | 7 | 1873.56 | 33 | 14.75 | 2693 | 1311 | 1.48 / 432.83 | 2 | 3 |
3 | 13 | 1505.56 | 18 | 14.79 | 2293 | 610 | 2.09 / 433.44 | 2 | 3 |
4 | 13 | 908.36 | 18 | 14.89 | 1534 | 411 | 2.51 / 433.85 | 2 | 4 |
5 | 13 | 485.88 | 18 | 14.99 | 984 | 266 | 2.77 / 434.11 | 2 | 4 |
6 | 13 | 21.00 | 18 | 15.12 | 351 | 96 | 2.87 / 434.21 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.08 | 321 | 799 | 3.67 / 435.01 | 2 | 8 |
Average= | 2.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 25 | 15.06 | 478 | 180 | 0.18 / 427.89 | 2 | 2 |
2 | 3 | 969.96 | -1 | 15.42 | 0 | 0 | 0.00 / 427.89 | 2 | 2 |
3 | 7 | 1876.12 | 32 | 14.78 | 2696 | 1275 | 1.46 / 429.16 | 2 | 3 |
4 | 13 | 1517.28 | 18 | 14.80 | 2294 | 611 | 2.07 / 429.77 | 2 | 3 |
5 | 13 | 917.96 | 18 | 14.88 | 1552 | 416 | 2.48 / 430.19 | 2 | 4 |
6 | 13 | 439.56 | 18 | 15.01 | 928 | 251 | 2.73 / 430.44 | 2 | 4 |
7 | 13 | 25.36 | 18 | 15.12 | 354 | 96 | 2.83 / 430.54 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.08 | 324 | 806 | 3.64 / 431.34 | 2 | 8 |
Average= | 2.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 25 | 15.06 | 473 | 178 | 0.18 / 424.23 | 2 | 2 |
2 | 7 | 1875.56 | 32 | 14.78 | 2710 | 1282 | 1.46 / 425.51 | 2 | 3 |
3 | 13 | 1417.88 | 18 | 14.80 | 2192 | 584 | 2.04 / 426.09 | 2 | 3 |
4 | 13 | 926.36 | 18 | 14.89 | 1569 | 421 | 2.46 / 426.51 | 2 | 3 |
5 | 13 | 491.08 | 18 | 14.99 | 995 | 268 | 2.73 / 426.78 | 2 | 4 |
6 | 13 | 22.44 | 18 | 15.12 | 362 | 99 | 2.83 / 426.88 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.07 | 332 | 826 | 3.66 / 427.71 | 2 | 7 |
Average= | 2.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 25 | 15.05 | 469 | 176 | 0.18 / 420.48 | 2 | 2 |
2 | 3 | 960.56 | -1 | 15.41 | 0 | 0 | 0.00 / 420.48 | 2 | 2 |
3 | 7 | 1872.20 | 32 | 14.79 | 2701 | 1278 | 1.45 / 421.76 | 2 | 3 |
4 | 13 | 1552.36 | 18 | 14.80 | 2338 | 623 | 2.08 / 422.38 | 2 | 3 |
5 | 13 | 985.84 | 18 | 14.89 | 1640 | 440 | 2.52 / 422.82 | 2 | 4 |
6 | 13 | 596.16 | 18 | 14.97 | 1142 | 308 | 2.82 / 423.13 | 2 | 4 |
7 | 13 | 37.56 | 18 | 15.13 | 376 | 102 | 2.93 / 423.23 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.08 | 328 | 816 | 3.74 / 424.05 | 2 | 11 |
Average= | 2.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 24 | 15.06 | 502 | 181 | 0.18 / 416.77 | 2 | 2 |
2 | 10 | 1008.96 | 3 | 15.03 | 1667 | 75 | 0.26 / 416.85 | 2 | 2 |
3 | 3 | 973.64 | -1 | 15.42 | 0 | 0 | 0.08 / 416.85 | 2 | 2 |
4 | 7 | 1872.40 | 32 | 14.77 | 2696 | 1274 | 1.53 / 418.12 | 2 | 3 |
5 | 13 | 1410.04 | 18 | 14.82 | 2162 | 577 | 2.11 / 418.70 | 2 | 3 |
6 | 13 | 940.16 | 18 | 14.88 | 1586 | 425 | 2.53 / 419.12 | 2 | 4 |
7 | 13 | 420.52 | 18 | 15.01 | 898 | 243 | 2.77 / 419.37 | 2 | 4 |
8 | 13 | 44.44 | 18 | 15.11 | 398 | 108 | 2.88 / 419.48 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.07 | 334 | 831 | 3.71 / 420.31 | 2 | 8 |
Average= | 2.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 24 | 15.05 | 490 | 177 | 0.18 / 412.99 | 2 | 2 |
2 | 3 | 1016.36 | 1 | 15.09 | 1724 | 26 | 0.20 / 413.02 | 2 | 3 |
3 | 7 | 1876.40 | 32 | 14.78 | 2685 | 1270 | 1.47 / 414.29 | 2 | 3 |
4 | 13 | 1497.16 | 18 | 14.81 | 2259 | 602 | 2.08 / 414.89 | 2 | 3 |
5 | 13 | 1015.04 | 18 | 14.87 | 1663 | 445 | 2.52 / 415.33 | 2 | 3 |
6 | 13 | 516.60 | 18 | 14.98 | 1041 | 281 | 2.80 / 415.61 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.08 | 333 | 829 | 3.63 / 416.44 | 2 | 7 |
8 | 14 | 0.04 | 30 | 15.06 | 333 | 150 | 3.78 / 416.59 | 2 | 7 |
Average= | 2.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 24 | 15.05 | 471 | 170 | 0.17 / 409.22 | 2 | 2 |
2 | 7 | 1873.00 | 33 | 14.77 | 2692 | 1312 | 1.48 / 410.53 | 2 | 3 |
3 | 13 | 1555.32 | 18 | 14.80 | 2333 | 622 | 2.10 / 411.15 | 2 | 3 |
4 | 13 | 946.04 | 18 | 14.89 | 1584 | 425 | 2.53 / 411.58 | 2 | 4 |
5 | 13 | 469.76 | 18 | 15.00 | 969 | 262 | 2.79 / 411.84 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.09 | 332 | 827 | 3.62 / 412.66 | 2 | 8 |
7 | 14 | 0.16 | 30 | 15.06 | 330 | 149 | 3.77 / 412.81 | 2 | 12 |
Average= | 2.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 24 | 15.06 | 465 | 168 | 0.17 / 405.48 | 2 | 2 |
2 | 7 | 1876.88 | 33 | 14.77 | 2701 | 1316 | 1.48 / 406.80 | 2 | 3 |
3 | 13 | 1398.80 | 18 | 14.82 | 2146 | 572 | 2.06 / 407.37 | 2 | 3 |
4 | 13 | 1013.84 | 18 | 14.86 | 1690 | 452 | 2.51 / 407.83 | 2 | 3 |
5 | 13 | 561.04 | 18 | 14.96 | 1096 | 295 | 2.80 / 408.12 | 2 | 4 |
6 | 13 | 30.88 | 18 | 15.11 | 379 | 103 | 2.91 / 408.22 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.08 | 331 | 824 | 3.73 / 409.05 | 2 | 9 |
Average= | 2.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 24 | 15.05 | 464 | 168 | 0.17 / 401.79 | 2 | 2 |
2 | 7 | 1875.16 | 32 | 14.79 | 2699 | 1277 | 1.44 / 403.07 | 2 | 3 |
3 | 13 | 1405.80 | 18 | 14.83 | 2160 | 577 | 2.02 / 403.65 | 2 | 3 |
4 | 13 | 1017.20 | 18 | 14.88 | 1678 | 449 | 2.47 / 404.10 | 2 | 4 |
5 | 13 | 560.32 | 18 | 14.98 | 1090 | 294 | 2.76 / 404.39 | 2 | 4 |
6 | 13 | 21.64 | 18 | 15.12 | 364 | 99 | 2.86 / 404.49 | 2 | 3 |
7 | 8 | -0.12 | 165 | 15.08 | 332 | 826 | 3.69 / 405.32 | 2 | 11 |
Average= | 2.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 24 | 15.06 | 469 | 170 | 0.17 / 398.10 | 2 | 2 |
2 | 7 | 1875.32 | 32 | 14.80 | 2696 | 1277 | 1.45 / 399.38 | 2 | 3 |
3 | 13 | 1502.84 | 18 | 14.80 | 2275 | 606 | 2.05 / 399.98 | 2 | 3 |
4 | 13 | 994.04 | 18 | 14.88 | 1658 | 444 | 2.50 / 400.43 | 2 | 3 |
5 | 13 | 508.84 | 18 | 15.00 | 1024 | 276 | 2.77 / 400.70 | 2 | 4 |
6 | 13 | 16.40 | 18 | 15.12 | 358 | 97 | 2.87 / 400.80 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.08 | 332 | 826 | 3.70 / 401.63 | 2 | 8 |
Average= | 2.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 24 | 15.04 | 487 | 176 | 0.18 / 394.60 | 2 | 2 |
2 | 7 | 1873.04 | 32 | 14.79 | 2683 | 1270 | 1.45 / 395.87 | 2 | 3 |
3 | 13 | 1416.20 | 18 | 14.83 | 2174 | 580 | 2.03 / 396.45 | 2 | 3 |
4 | 13 | 888.20 | 18 | 14.90 | 1518 | 407 | 2.43 / 396.85 | 2 | 4 |
5 | 13 | 502.56 | 18 | 14.99 | 1011 | 273 | 2.71 / 397.13 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.09 | 323 | 804 | 3.51 / 397.93 | 2 | 4 |
Average= | 2.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 25 | 15.07 | 461 | 174 | 0.17 / 390.78 | 2 | 2 |
2 | 3 | 979.84 | -1 | 15.41 | 0 | 0 | 0.00 / 390.78 | 2 | 2 |
3 | 7 | 1873.92 | 32 | 14.78 | 2693 | 1274 | 1.45 / 392.05 | 2 | 3 |
4 | 13 | 1462.80 | 18 | 14.82 | 2212 | 590 | 2.04 / 392.64 | 2 | 3 |
5 | 13 | 966.72 | 18 | 14.89 | 1601 | 429 | 2.47 / 393.07 | 2 | 3 |
6 | 13 | 476.44 | 18 | 15.01 | 976 | 264 | 2.73 / 393.33 | 2 | 4 |
7 | 13 | 77.12 | 18 | 15.11 | 435 | 118 | 2.85 / 393.45 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.08 | 330 | 821 | 3.67 / 394.27 | 2 | 10 |
9 | 14 | 0.08 | 30 | 15.06 | 328 | 148 | 3.82 / 394.42 | 2 | 9 |
Average= | 2.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 25 | 15.07 | 457 | 172 | 0.17 / 387.22 | 2 | 2 |
2 | 3 | 969.44 | -1 | 15.42 | 0 | 0 | 0.00 / 387.22 | 2 | 2 |
3 | 7 | 1873.08 | 32 | 14.78 | 2686 | 1270 | 1.44 / 388.49 | 2 | 3 |
4 | 13 | 1405.60 | 18 | 14.82 | 2143 | 572 | 2.01 / 389.06 | 2 | 3 |
5 | 13 | 1024.24 | 18 | 14.85 | 1694 | 453 | 2.47 / 389.52 | 2 | 3 |
6 | 13 | 518.24 | 18 | 14.99 | 1035 | 279 | 2.75 / 389.79 | 2 | 4 |
7 | 8 | 0.28 | 165 | 15.09 | 324 | 807 | 3.55 / 390.60 | 2 | 5 |
Average= | 2.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 24 | 15.04 | 491 | 177 | 0.18 / 383.37 | 2 | 2 |
2 | 10 | 1018.68 | 2 | 15.05 | 1720 | 52 | 0.23 / 383.42 | 2 | 3 |
3 | 3 | 977.84 | -1 | 15.42 | 0 | 0 | 0.05 / 383.42 | 2 | 3 |
4 | 7 | 1873.64 | 32 | 14.80 | 2689 | 1274 | 1.50 / 384.70 | 2 | 3 |
5 | 13 | 1457.12 | 18 | 14.81 | 2226 | 593 | 2.10 / 385.29 | 2 | 3 |
6 | 13 | 968.68 | 18 | 14.89 | 1608 | 431 | 2.53 / 385.72 | 2 | 4 |
7 | 13 | 431.88 | 18 | 15.03 | 914 | 247 | 2.77 / 385.97 | 2 | 4 |
8 | 13 | 51.44 | 18 | 15.12 | 409 | 111 | 2.89 / 386.08 | 2 | 4 |
9 | 8 | 0.08 | 165 | 15.08 | 331 | 824 | 3.71 / 386.90 | 2 | 8 |
10 | 14 | 0.08 | 30 | 15.05 | 320 | 144 | 3.85 / 387.05 | 2 | 7 |
Average= | 2.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 24 | 15.05 | 468 | 169 | 0.17 / 379.65 | 2 | 2 |
2 | 7 | 1872.24 | 32 | 14.79 | 2692 | 1274 | 1.44 / 380.92 | 2 | 3 |
3 | 13 | 1498.12 | 18 | 14.81 | 2264 | 604 | 2.05 / 381.52 | 2 | 3 |
4 | 13 | 906.24 | 18 | 14.90 | 1536 | 412 | 2.46 / 381.94 | 2 | 4 |
5 | 13 | 533.80 | 18 | 14.99 | 1063 | 287 | 2.75 / 382.22 | 2 | 4 |
6 | 13 | 78.88 | 18 | 15.11 | 450 | 122 | 2.87 / 382.34 | 2 | 4 |
7 | 8 | -0.12 | 165 | 15.07 | 342 | 850 | 3.72 / 383.20 | 2 | 6 |
Average= | 2.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 24 | 15.05 | 485 | 175 | 0.18 / 375.81 | 2 | 2 |
2 | 7 | 1878.00 | 32 | 14.80 | 2705 | 1281 | 1.46 / 377.09 | 2 | 3 |
3 | 13 | 1464.28 | 18 | 14.81 | 2241 | 597 | 2.05 / 377.69 | 2 | 3 |
4 | 13 | 931.80 | 18 | 14.89 | 1572 | 421 | 2.48 / 378.11 | 2 | 4 |
5 | 13 | 497.64 | 18 | 15.00 | 1005 | 271 | 2.75 / 378.38 | 2 | 4 |
6 | 13 | 65.00 | 18 | 15.11 | 424 | 115 | 2.86 / 378.50 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.07 | 334 | 831 | 3.69 / 379.33 | 2 | 6 |
8 | 14 | 0.16 | 30 | 15.05 | 328 | 148 | 3.84 / 379.48 | 3 | 12 |
Average= | 2.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 25 | 15.05 | 475 | 179 | 0.18 / 372.11 | 2 | 2 |
2 | 3 | 952.44 | -1 | 15.43 | 0 | 0 | 0.00 / 372.11 | 2 | 2 |
3 | 3 | 981.76 | -1 | 15.45 | 0 | 0 | 0.00 / 372.11 | 2 | 2 |
4 | 7 | 1876.44 | 32 | 14.80 | 2697 | 1277 | 1.46 / 373.38 | 2 | 3 |
5 | 13 | 1451.44 | 18 | 14.82 | 2220 | 592 | 2.05 / 373.98 | 2 | 3 |
6 | 13 | 925.84 | 18 | 14.91 | 1549 | 416 | 2.46 / 374.39 | 2 | 4 |
7 | 13 | 538.88 | 18 | 14.98 | 1067 | 288 | 2.75 / 374.68 | 2 | 4 |
8 | 13 | 78.96 | 18 | 15.11 | 454 | 123 | 2.88 / 374.80 | 2 | 4 |
9 | 8 | 0.08 | 165 | 15.07 | 335 | 833 | 3.71 / 375.64 | 2 | 6 |
Average= | 2.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 25 | 15.06 | 461 | 174 | 0.17 / 368.41 | 2 | 2 |
2 | 7 | 1876.24 | 32 | 14.79 | 2699 | 1277 | 1.45 / 369.68 | 2 | 3 |
3 | 13 | 1407.08 | 18 | 14.84 | 2165 | 578 | 2.03 / 370.26 | 2 | 3 |
4 | 13 | 975.28 | 18 | 14.90 | 1619 | 434 | 2.46 / 370.70 | 2 | 4 |
5 | 13 | 538.20 | 18 | 14.98 | 1059 | 286 | 2.75 / 370.98 | 2 | 4 |
6 | 13 | 85.84 | 18 | 15.11 | 450 | 122 | 2.87 / 371.10 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.08 | 331 | 824 | 3.70 / 371.93 | 2 | 8 |
Average= | 2.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 25 | 15.06 | 470 | 177 | 0.18 / 364.77 | 2 | 2 |
2 | 7 | 1874.60 | 32 | 14.79 | 2689 | 1273 | 1.45 / 366.04 | 2 | 3 |
3 | 13 | 1403.04 | 18 | 14.83 | 2163 | 577 | 2.03 / 366.62 | 2 | 3 |
4 | 13 | 967.44 | 18 | 14.89 | 1628 | 436 | 2.46 / 367.06 | 2 | 3 |
5 | 13 | 468.88 | 18 | 15.00 | 973 | 263 | 2.73 / 367.32 | 2 | 4 |
6 | 13 | 74.48 | 18 | 15.12 | 427 | 116 | 2.84 / 367.44 | 2 | 4 |
7 | 8 | 0.00 | 165 | 15.09 | 320 | 797 | 3.64 / 368.23 | 2 | 7 |
Average= | 2.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 26 | 15.06 | 451 | 177 | 0.18 / 361.13 | 2 | 2 |
2 | 3 | 982.64 | -1 | 15.43 | 0 | 0 | 0.00 / 361.13 | 2 | 2 |
3 | 3 | 1020.28 | 1 | 15.12 | 1697 | 26 | 0.20 / 361.16 | 2 | 3 |
4 | 7 | 1876.48 | 32 | 14.80 | 2686 | 1272 | 1.47 / 362.43 | 2 | 3 |
5 | 13 | 1411.32 | 18 | 14.84 | 2155 | 576 | 2.05 / 363.01 | 2 | 3 |
6 | 13 | 922.08 | 18 | 14.90 | 1545 | 414 | 2.46 / 363.42 | 2 | 4 |
7 | 13 | 489.48 | 18 | 15.00 | 997 | 269 | 2.73 / 363.69 | 2 | 4 |
8 | 13 | 54.04 | 18 | 15.13 | 394 | 107 | 2.84 / 363.80 | 2 | 4 |
9 | 8 | 0.04 | 165 | 15.09 | 320 | 797 | 3.64 / 364.59 | 2 | 9 |
Average= | 2.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 26 | 15.06 | 468 | 183 | 0.18 / 357.52 | 2 | 2 |
2 | 7 | 1874.28 | 32 | 14.81 | 2693 | 1276 | 1.46 / 358.79 | 2 | 3 |
3 | 13 | 1452.28 | 18 | 14.84 | 2194 | 586 | 2.05 / 359.38 | 2 | 3 |
4 | 13 | 950.08 | 18 | 14.91 | 1586 | 426 | 2.47 / 359.81 | 2 | 4 |
5 | 13 | 462.76 | 18 | 15.02 | 950 | 257 | 2.73 / 360.06 | 2 | 4 |
6 | 13 | 47.28 | 18 | 15.12 | 387 | 105 | 2.83 / 360.17 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.09 | 317 | 789 | 3.62 / 360.96 | 2 | 11 |
Average= | 2.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 25 | 15.05 | 478 | 180 | 0.18 / 353.79 | 2 | 2 |
2 | 3 | 1028.16 | 1 | 15.09 | 1744 | 26 | 0.21 / 353.81 | 2 | 2 |
3 | 7 | 1873.88 | 33 | 14.79 | 2695 | 1315 | 1.52 / 355.13 | 2 | 3 |
4 | 13 | 1497.40 | 18 | 14.82 | 2262 | 603 | 2.12 / 355.73 | 2 | 3 |
5 | 13 | 892.84 | 18 | 14.91 | 1528 | 410 | 2.54 / 356.14 | 2 | 4 |
6 | 13 | 517.12 | 18 | 15.00 | 1037 | 280 | 2.81 / 356.42 | 2 | 4 |
7 | 13 | 62.64 | 18 | 15.11 | 414 | 113 | 2.93 / 356.53 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.09 | 321 | 799 | 3.73 / 357.33 | 2 | 8 |
Average= | 2.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 25 | 15.06 | 459 | 173 | 0.17 / 350.04 | 2 | 2 |
2 | 3 | 980.16 | -1 | 15.43 | 0 | 0 | 0.00 / 350.04 | 2 | 2 |
3 | 3 | 1020.64 | 1 | 15.11 | 1697 | 26 | 0.20 / 350.07 | 2 | 3 |
4 | 7 | 1875.72 | 33 | 14.80 | 2689 | 1313 | 1.51 / 351.38 | 2 | 3 |
5 | 13 | 1451.04 | 18 | 14.85 | 2198 | 588 | 2.10 / 351.97 | 2 | 3 |
6 | 13 | 957.76 | 18 | 14.90 | 1602 | 430 | 2.53 / 352.40 | 2 | 3 |
7 | 13 | 467.76 | 18 | 15.02 | 955 | 258 | 2.79 / 352.66 | 2 | 4 |
8 | 13 | 44.80 | 18 | 15.13 | 405 | 110 | 2.90 / 352.77 | 2 | 4 |
9 | 8 | -0.08 | 165 | 15.08 | 337 | 839 | 3.74 / 353.61 | 2 | 10 |
Average= | 2.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 26 | 15.07 | 461 | 181 | 0.18 / 346.26 | 2 | 2 |
2 | 3 | 982.16 | -1 | 15.43 | 0 | 0 | 0.00 / 346.26 | 2 | 2 |
3 | 7 | 1873.72 | 32 | 14.80 | 2686 | 1272 | 1.45 / 347.53 | 2 | 3 |
4 | 13 | 1505.36 | 18 | 14.82 | 2272 | 606 | 2.06 / 348.13 | 2 | 3 |
5 | 13 | 1001.12 | 18 | 14.89 | 1643 | 440 | 2.50 / 348.57 | 2 | 4 |
6 | 13 | 542.84 | 18 | 14.99 | 1062 | 287 | 2.79 / 348.86 | 2 | 4 |
7 | 13 | 76.04 | 18 | 15.12 | 431 | 117 | 2.90 / 348.98 | 2 | 4 |
8 | 13 | 18.12 | 18 | 15.13 | 356 | 97 | 3.00 / 349.08 | 2 | 4 |
9 | 8 | 0.12 | 165 | 15.08 | 320 | 796 | 3.80 / 349.87 | 2 | 11 |
Average= | 2.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 26 | 15.07 | 462 | 181 | 0.18 / 342.64 | 2 | 2 |
2 | 3 | 975.92 | -1 | 15.44 | 0 | 0 | 0.00 / 342.64 | 2 | 2 |
3 | 7 | 1873.64 | 32 | 14.80 | 2693 | 1275 | 1.46 / 343.92 | 2 | 3 |
4 | 13 | 1493.76 | 18 | 14.83 | 2260 | 603 | 2.06 / 344.52 | 2 | 3 |
5 | 13 | 905.60 | 18 | 14.91 | 1531 | 411 | 2.47 / 344.93 | 2 | 3 |
6 | 13 | 436.08 | 18 | 15.05 | 917 | 248 | 2.72 / 345.18 | 2 | 4 |
7 | 13 | 52.48 | 18 | 15.14 | 394 | 107 | 2.83 / 345.29 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.09 | 316 | 787 | 3.61 / 346.08 | 2 | 7 |
Average= | 2.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 26 | 15.05 | 474 | 185 | 0.19 / 338.95 | 2 | 2 |
2 | 7 | 1872.04 | 32 | 14.82 | 2703 | 1282 | 1.47 / 340.23 | 2 | 3 |
3 | 13 | 1445.20 | 18 | 14.85 | 2201 | 588 | 2.06 / 340.82 | 2 | 3 |
4 | 13 | 1001.92 | 18 | 14.91 | 1644 | 441 | 2.50 / 341.26 | 2 | 4 |
5 | 13 | 598.24 | 18 | 14.98 | 1136 | 306 | 2.80 / 341.57 | 2 | 4 |
6 | 13 | 49.96 | 18 | 15.14 | 391 | 107 | 2.91 / 341.67 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.09 | 317 | 789 | 3.70 / 342.46 | 2 | 9 |
Average= | 2.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 26 | 15.07 | 460 | 180 | 0.18 / 335.21 | 2 | 2 |
2 | 10 | 1010.32 | 2 | 15.07 | 1691 | 51 | 0.23 / 335.26 | 2 | 3 |
3 | 3 | 976.60 | -1 | 15.44 | 0 | 0 | 0.05 / 335.26 | 2 | 3 |
4 | 7 | 1872.40 | 32 | 14.80 | 2683 | 1271 | 1.50 / 336.53 | 2 | 3 |
5 | 13 | 1491.76 | 18 | 14.84 | 2258 | 603 | 2.11 / 337.14 | 2 | 3 |
6 | 13 | 896.44 | 18 | 14.92 | 1520 | 408 | 2.51 / 337.55 | 2 | 4 |
7 | 13 | 471.72 | 18 | 15.03 | 961 | 260 | 2.77 / 337.81 | 2 | 4 |
8 | 13 | 73.12 | 18 | 15.12 | 445 | 121 | 2.89 / 337.93 | 2 | 4 |
9 | 8 | 0.04 | 165 | 15.08 | 336 | 836 | 3.73 / 338.76 | 2 | 9 |
Average= | 2.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 26 | 15.08 | 458 | 180 | 0.18 / 331.60 | 2 | 2 |
2 | 7 | 1877.64 | 32 | 14.81 | 2696 | 1278 | 1.46 / 332.88 | 2 | 3 |
3 | 13 | 1362.28 | 18 | 14.85 | 2099 | 561 | 2.02 / 333.44 | 2 | 3 |
4 | 13 | 903.00 | 18 | 14.92 | 1515 | 407 | 2.43 / 333.85 | 2 | 4 |
5 | 13 | 485.00 | 18 | 15.02 | 974 | 263 | 2.69 / 334.11 | 2 | 4 |
6 | 13 | 47.32 | 18 | 15.13 | 394 | 107 | 2.80 / 334.22 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.09 | 326 | 812 | 3.61 / 335.03 | 2 | 9 |
Average= | 2.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 26 | 15.07 | 462 | 181 | 0.18 / 327.93 | 2 | 2 |
2 | 7 | 1874.12 | 32 | 14.81 | 2692 | 1276 | 1.46 / 329.20 | 2 | 3 |
3 | 13 | 1517.96 | 18 | 14.84 | 2281 | 609 | 2.07 / 329.81 | 2 | 3 |
4 | 13 | 1051.72 | 18 | 14.90 | 1697 | 455 | 2.52 / 330.27 | 2 | 3 |
5 | 13 | 454.92 | 18 | 15.04 | 956 | 259 | 2.78 / 330.53 | 2 | 4 |
6 | 13 | 39.12 | 18 | 15.15 | 378 | 103 | 2.88 / 330.63 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.11 | 319 | 795 | 3.68 / 331.43 | 2 | 7 |
Average= | 2.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 25 | 15.08 | 461 | 174 | 0.17 / 324.32 | 2 | 2 |
2 | 7 | 1873.12 | 32 | 14.82 | 2685 | 1273 | 1.45 / 325.60 | 2 | 3 |
3 | 13 | 1397.56 | 18 | 14.87 | 2142 | 573 | 2.02 / 326.17 | 2 | 3 |
4 | 13 | 911.00 | 18 | 14.93 | 1532 | 412 | 2.43 / 326.58 | 2 | 4 |
5 | 13 | 484.96 | 18 | 15.04 | 984 | 266 | 2.70 / 326.85 | 2 | 4 |
6 | 13 | 45.16 | 18 | 15.15 | 383 | 104 | 2.80 / 326.95 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.11 | 318 | 793 | 3.60 / 327.75 | 2 | 7 |
Average= | 2.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 25 | 15.09 | 465 | 175 | 0.18 / 320.71 | 2 | 2 |
2 | 7 | 1872.44 | 32 | 14.81 | 2677 | 1269 | 1.44 / 321.97 | 2 | 3 |
3 | 13 | 1488.20 | 18 | 14.84 | 2259 | 603 | 2.05 / 322.58 | 2 | 3 |
4 | 13 | 895.64 | 18 | 14.94 | 1515 | 407 | 2.45 / 322.99 | 2 | 3 |
5 | 13 | 474.72 | 18 | 15.04 | 968 | 262 | 2.72 / 323.25 | 2 | 4 |
6 | 13 | 39.76 | 18 | 15.16 | 377 | 103 | 2.82 / 323.35 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.11 | 321 | 800 | 3.62 / 324.15 | 2 | 8 |
Average= | 2.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 26 | 15.12 | 451 | 177 | 0.18 / 317.08 | 2 | 2 |
2 | 3 | 956.76 | -1 | 15.46 | 0 | 0 | 0.00 / 317.08 | 2 | 2 |
3 | 7 | 1871.88 | 32 | 14.82 | 2683 | 1272 | 1.45 / 318.35 | 2 | 3 |
4 | 13 | 1480.96 | 18 | 14.86 | 2240 | 599 | 2.05 / 318.95 | 2 | 3 |
5 | 13 | 907.92 | 18 | 14.94 | 1529 | 411 | 2.46 / 319.36 | 2 | 4 |
6 | 13 | 527.24 | 18 | 15.04 | 1032 | 279 | 2.74 / 319.64 | 2 | 4 |
7 | 13 | 35.44 | 18 | 15.16 | 367 | 100 | 2.84 / 319.74 | 2 | 4 |
8 | 8 | 0.12 | 165 | 15.12 | 317 | 791 | 3.63 / 320.53 | 2 | 6 |
Average= | 2.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 25 | 15.10 | 463 | 175 | 0.17 / 313.37 | 2 | 2 |
2 | 10 | 1001.40 | 2 | 15.10 | 1671 | 50 | 0.23 / 313.42 | 2 | 2 |
3 | 7 | 1877.28 | 33 | 14.83 | 2700 | 1321 | 1.55 / 314.74 | 2 | 3 |
4 | 13 | 1406.32 | 18 | 14.88 | 2146 | 575 | 2.12 / 315.32 | 2 | 3 |
5 | 13 | 916.40 | 18 | 14.95 | 1539 | 414 | 2.54 / 315.73 | 2 | 4 |
6 | 13 | 522.28 | 18 | 15.05 | 1022 | 277 | 2.81 / 316.01 | 2 | 4 |
7 | 13 | 53.84 | 18 | 15.17 | 398 | 109 | 2.92 / 316.12 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.13 | 314 | 784 | 3.70 / 316.90 | 2 | 8 |
Average= | 2.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 24 | 15.11 | 446 | 162 | 0.16 / 309.72 | 2 | 2 |
2 | 7 | 1873.20 | 32 | 14.83 | 2694 | 1278 | 1.44 / 311.00 | 2 | 3 |
3 | 13 | 1460.96 | 18 | 14.86 | 2215 | 592 | 2.03 / 311.59 | 2 | 3 |
4 | 13 | 933.60 | 18 | 14.93 | 1567 | 421 | 2.45 / 312.01 | 2 | 3 |
5 | 13 | 510.84 | 18 | 15.03 | 1022 | 276 | 2.73 / 312.29 | 2 | 4 |
6 | 13 | 69.56 | 18 | 15.16 | 417 | 114 | 2.84 / 312.40 | 2 | 4 |
7 | 8 | 0.32 | 165 | 15.12 | 318 | 793 | 3.64 / 313.20 | 2 | 6 |
Average= | 2.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 24 | 15.11 | 458 | 166 | 0.17 / 306.07 | 2 | 2 |
2 | 7 | 1874.56 | 32 | 14.84 | 2691 | 1278 | 1.44 / 307.35 | 2 | 3 |
3 | 13 | 1456.80 | 18 | 14.87 | 2211 | 592 | 2.04 / 307.94 | 2 | 3 |
4 | 13 | 1009.48 | 18 | 14.93 | 1654 | 444 | 2.48 / 308.39 | 2 | 3 |
5 | 13 | 511.52 | 18 | 15.05 | 1006 | 273 | 2.75 / 308.66 | 2 | 4 |
6 | 13 | 62.68 | 18 | 15.17 | 400 | 109 | 2.86 / 308.77 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.14 | 316 | 789 | 3.65 / 309.56 | 2 | 6 |
Average= | 2.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 24 | 15.12 | 436 | 158 | 0.16 / 302.37 | 2 | 2 |
2 | 7 | 1872.28 | 32 | 14.83 | 2691 | 1277 | 1.44 / 303.65 | 2 | 3 |
3 | 13 | 1549.56 | 18 | 14.85 | 2306 | 616 | 2.05 / 304.27 | 2 | 3 |
4 | 13 | 939.32 | 18 | 14.95 | 1563 | 421 | 2.47 / 304.69 | 2 | 3 |
5 | 13 | 556.44 | 18 | 15.03 | 1063 | 288 | 2.76 / 304.98 | 2 | 4 |
6 | 13 | 45.44 | 18 | 15.16 | 399 | 109 | 2.87 / 305.09 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.13 | 329 | 821 | 3.69 / 305.91 | 2 | 7 |
Average= | 2.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 24 | 15.12 | 454 | 165 | 0.16 / 298.77 | 2 | 2 |
2 | 3 | 1024.20 | 1 | 15.14 | 1711 | 26 | 0.19 / 298.80 | 2 | 3 |
3 | 7 | 1873.08 | 32 | 14.84 | 2674 | 1270 | 1.46 / 300.06 | 2 | 3 |
4 | 13 | 1452.32 | 18 | 14.87 | 2205 | 590 | 2.05 / 300.66 | 2 | 3 |
5 | 13 | 958.24 | 18 | 14.95 | 1598 | 430 | 2.48 / 301.09 | 2 | 4 |
6 | 13 | 469.96 | 18 | 15.07 | 957 | 260 | 2.74 / 301.34 | 2 | 4 |
7 | 13 | 37.04 | 18 | 15.19 | 363 | 99 | 2.84 / 301.44 | 2 | 4 |
8 | 8 | -0.04 | 165 | 15.15 | 309 | 772 | 3.61 / 302.22 | 2 | 11 |
Average= | 2.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 23 | 15.13 | 457 | 159 | 0.16 / 295.09 | 2 | 2 |
2 | 7 | 1874.64 | 33 | 14.83 | 2704 | 1323 | 1.48 / 296.42 | 2 | 3 |
3 | 13 | 1483.24 | 18 | 14.87 | 2238 | 599 | 2.08 / 297.02 | 2 | 3 |
4 | 13 | 982.04 | 18 | 14.95 | 1628 | 438 | 2.52 / 297.45 | 2 | 3 |
5 | 13 | 445.20 | 18 | 15.08 | 935 | 254 | 2.77 / 297.71 | 2 | 4 |
6 | 13 | 45.28 | 18 | 15.18 | 381 | 104 | 2.88 / 297.81 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.15 | 317 | 792 | 3.67 / 298.60 | 2 | 10 |
Average= | 2.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 23 | 15.10 | 467 | 162 | 0.16 / 291.41 | 2 | 2 |
2 | 7 | 1875.28 | 32 | 14.83 | 2694 | 1278 | 1.44 / 292.69 | 2 | 3 |
3 | 13 | 1562.56 | 18 | 14.85 | 2338 | 625 | 2.07 / 293.32 | 2 | 3 |
4 | 13 | 956.72 | 18 | 14.95 | 1583 | 426 | 2.49 / 293.74 | 2 | 4 |
5 | 13 | 524.20 | 18 | 15.06 | 1028 | 279 | 2.77 / 294.02 | 2 | 4 |
6 | 13 | 32.48 | 18 | 15.19 | 373 | 102 | 2.87 / 294.12 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.15 | 325 | 812 | 3.68 / 294.93 | 2 | 8 |
Average= | 2.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 23 | 15.13 | 462 | 161 | 0.16 / 287.78 | 2 | 2 |
2 | 7 | 1875.28 | 32 | 14.83 | 2685 | 1274 | 1.43 / 289.06 | 2 | 3 |
3 | 13 | 1502.20 | 18 | 14.86 | 2251 | 602 | 2.04 / 289.66 | 2 | 3 |
4 | 13 | 951.92 | 18 | 14.95 | 1582 | 426 | 2.46 / 290.08 | 2 | 4 |
5 | 13 | 464.60 | 18 | 15.07 | 960 | 260 | 2.72 / 290.34 | 2 | 4 |
6 | 13 | 29.84 | 18 | 15.19 | 366 | 100 | 2.82 / 290.45 | 2 | 4 |
7 | 8 | 0.00 | 165 | 15.15 | 322 | 805 | 3.63 / 291.25 | 2 | 10 |
Average= | 2.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 23 | 15.13 | 464 | 161 | 0.16 / 284.15 | 2 | 2 |
2 | 7 | 1873.80 | 32 | 14.83 | 2703 | 1283 | 1.44 / 285.44 | 2 | 3 |
3 | 13 | 1443.60 | 18 | 14.86 | 2188 | 585 | 2.03 / 286.02 | 2 | 3 |
4 | 13 | 962.08 | 18 | 14.94 | 1598 | 430 | 2.46 / 286.45 | 2 | 4 |
5 | 13 | 479.52 | 18 | 15.07 | 976 | 265 | 2.72 / 286.72 | 2 | 4 |
6 | 13 | 41.56 | 18 | 15.20 | 377 | 103 | 2.83 / 286.82 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.16 | 321 | 803 | 3.63 / 287.62 | 2 | 8 |
Average= | 2.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 23 | 15.14 | 473 | 165 | 0.16 / 280.37 | 2 | 2 |
2 | 7 | 1874.76 | 32 | 14.83 | 2688 | 1276 | 1.44 / 281.65 | 2 | 3 |
3 | 13 | 1401.08 | 18 | 14.88 | 2159 | 578 | 2.02 / 282.22 | 2 | 3 |
4 | 13 | 925.80 | 18 | 14.96 | 1563 | 421 | 2.44 / 282.64 | 2 | 4 |
5 | 13 | 490.96 | 18 | 15.07 | 1003 | 272 | 2.71 / 282.92 | 2 | 4 |
6 | 13 | 39.56 | 18 | 15.19 | 384 | 105 | 2.82 / 283.02 | 2 | 4 |
7 | 8 | 0.24 | 165 | 15.15 | 329 | 822 | 3.64 / 283.84 | 2 | 9 |
8 | 14 | 0.24 | 30 | 15.13 | 326 | 148 | 3.79 / 283.99 | 2 | 9 |
Average= | 2.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.84 | 23 | 15.15 | 459 | 160 | 0.16 / 276.57 | 2 | 2 |
2 | 3 | 1023.12 | 1 | 15.13 | 1712 | 26 | 0.19 / 276.59 | 2 | 3 |
3 | 7 | 1878.64 | 32 | 14.85 | 2695 | 1281 | 1.47 / 277.87 | 2 | 3 |
4 | 13 | 1435.56 | 18 | 14.88 | 2182 | 584 | 2.05 / 278.46 | 2 | 3 |
5 | 13 | 905.52 | 18 | 14.98 | 1530 | 413 | 2.46 / 278.87 | 2 | 4 |
6 | 13 | 475.04 | 18 | 15.09 | 960 | 261 | 2.72 / 279.13 | 2 | 4 |
7 | 13 | 18.64 | 18 | 15.22 | 364 | 100 | 2.82 / 279.23 | 2 | 4 |
8 | 8 | -0.04 | 165 | 15.17 | 331 | 829 | 3.65 / 280.06 | 2 | 6 |
9 | 14 | -0.04 | 30 | 15.14 | 322 | 146 | 3.80 / 280.20 | 3 | 7 |
Average= | 2.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 23 | 15.14 | 463 | 161 | 0.16 / 272.97 | 2 | 2 |
2 | 3 | 980.48 | -1 | 15.47 | 0 | 0 | 0.00 / 272.97 | 2 | 2 |
3 | 7 | 1873.12 | 33 | 14.83 | 2684 | 1314 | 1.47 / 274.29 | 2 | 3 |
4 | 13 | 1508.36 | 18 | 14.86 | 2263 | 605 | 2.08 / 274.89 | 2 | 3 |
5 | 13 | 953.36 | 18 | 14.96 | 1588 | 428 | 2.51 / 275.32 | 2 | 3 |
6 | 13 | 509.60 | 18 | 15.08 | 1014 | 275 | 2.78 / 275.60 | 2 | 4 |
7 | 8 | 0.32 | 165 | 15.17 | 324 | 811 | 3.59 / 276.41 | 2 | 8 |
Average= | 2.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 23 | 15.17 | 469 | 164 | 0.16 / 269.44 | 2 | 2 |
2 | 7 | 1866.80 | 32 | 14.85 | 2669 | 1268 | 1.43 / 270.71 | 2 | 3 |
3 | 13 | 1482.96 | 18 | 14.87 | 2250 | 602 | 2.03 / 271.31 | 2 | 3 |
4 | 13 | 949.24 | 18 | 14.96 | 1585 | 427 | 2.46 / 271.74 | 2 | 4 |
5 | 13 | 520.40 | 18 | 15.07 | 1030 | 279 | 2.74 / 272.02 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.18 | 318 | 796 | 3.54 / 272.81 | 2 | 8 |
Average= | 2.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 23 | 15.16 | 476 | 166 | 0.17 / 265.87 | 2 | 2 |
2 | 3 | 981.76 | -1 | 15.48 | 0 | 0 | 0.00 / 265.87 | 2 | 2 |
3 | 3 | 1021.80 | 1 | 15.16 | 1712 | 26 | 0.19 / 265.90 | 2 | 3 |
4 | 7 | 1865.32 | 32 | 14.85 | 2681 | 1274 | 1.47 / 267.17 | 2 | 3 |
5 | 13 | 1440.04 | 18 | 14.89 | 2196 | 589 | 2.05 / 267.76 | 2 | 3 |
6 | 13 | 1009.88 | 18 | 14.95 | 1660 | 447 | 2.50 / 268.21 | 2 | 3 |
7 | 13 | 463.16 | 18 | 15.10 | 958 | 260 | 2.76 / 268.47 | 2 | 4 |
8 | 8 | 0.20 | 165 | 15.18 | 323 | 809 | 3.57 / 269.28 | 2 | 5 |
Average= | 2.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 24 | 15.16 | 456 | 166 | 0.17 / 262.37 | 2 | 2 |
2 | 3 | 970.68 | -1 | 15.47 | 0 | 0 | 0.00 / 262.37 | 2 | 2 |
3 | 7 | 1866.88 | 33 | 14.83 | 2685 | 1314 | 1.48 / 263.68 | 2 | 3 |
4 | 13 | 1402.36 | 18 | 14.88 | 2143 | 574 | 2.05 / 264.26 | 2 | 3 |
5 | 13 | 869.72 | 18 | 15.00 | 1474 | 398 | 2.45 / 264.65 | 2 | 3 |
6 | 13 | 488.08 | 18 | 15.09 | 980 | 266 | 2.72 / 264.92 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.18 | 313 | 784 | 3.50 / 265.70 | 2 | 6 |
Average= | 2.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 24 | 15.16 | 446 | 162 | 0.16 / 258.84 | 2 | 2 |
2 | 7 | 1863.12 | 32 | 14.85 | 2675 | 1271 | 1.43 / 260.11 | 2 | 3 |
3 | 13 | 1484.64 | 18 | 14.88 | 2239 | 600 | 2.03 / 260.71 | 2 | 3 |
4 | 13 | 936.20 | 18 | 14.98 | 1553 | 419 | 2.45 / 261.13 | 2 | 3 |
5 | 13 | 453.68 | 18 | 15.09 | 950 | 258 | 2.71 / 261.39 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.18 | 324 | 812 | 3.52 / 262.20 | 2 | 7 |
Average= | 2.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 23 | 15.17 | 444 | 155 | 0.15 / 255.27 | 2 | 2 |
2 | 3 | 1019.08 | 1 | 15.16 | 1696 | 26 | 0.18 / 255.30 | 2 | 3 |
3 | 3 | 1017.80 | 1 | 15.20 | 1708 | 26 | 0.21 / 255.33 | 2 | 3 |
4 | 7 | 1867.20 | 33 | 14.84 | 2673 | 1309 | 1.52 / 256.63 | 2 | 3 |
5 | 13 | 1434.28 | 18 | 14.89 | 2166 | 581 | 2.10 / 257.22 | 2 | 3 |
6 | 13 | 937.12 | 18 | 14.99 | 1565 | 422 | 2.52 / 257.64 | 2 | 4 |
7 | 13 | 495.92 | 18 | 15.09 | 989 | 269 | 2.79 / 257.91 | 2 | 4 |
8 | 8 | -0.04 | 165 | 15.20 | 309 | 775 | 3.56 / 258.68 | 2 | 6 |
Average= | 2.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 23 | 15.16 | 463 | 161 | 0.16 / 251.82 | 2 | 2 |
2 | 3 | 982.12 | -1 | 15.50 | 0 | 0 | 0.00 / 251.82 | 2 | 2 |
3 | 7 | 1864.24 | 32 | 14.86 | 2675 | 1272 | 1.43 / 253.09 | 2 | 3 |
4 | 13 | 1348.56 | 18 | 14.92 | 2070 | 556 | 1.99 / 253.65 | 2 | 3 |
5 | 13 | 968.60 | 18 | 14.98 | 1601 | 432 | 2.42 / 254.08 | 2 | 3 |
6 | 13 | 482.20 | 18 | 15.11 | 968 | 263 | 2.68 / 254.34 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.19 | 309 | 774 | 3.46 / 255.12 | 2 | 5 |
Average= | 2.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 23 | 15.15 | 469 | 163 | 0.16 / 248.34 | 2 | 2 |
2 | 7 | 1865.36 | 32 | 14.85 | 2687 | 1277 | 1.44 / 249.62 | 2 | 3 |
3 | 13 | 1389.24 | 18 | 14.90 | 2144 | 575 | 2.02 / 250.19 | 2 | 3 |
4 | 13 | 908.64 | 18 | 14.99 | 1528 | 412 | 2.43 / 250.61 | 2 | 3 |
5 | 13 | 425.12 | 18 | 15.13 | 906 | 247 | 2.67 / 250.85 | 2 | 4 |
6 | 8 | 0.36 | 165 | 15.20 | 322 | 808 | 3.48 / 251.66 | 2 | 7 |
Average= | 2.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 23 | 15.18 | 454 | 159 | 0.16 / 244.61 | 2 | 2 |
2 | 7 | 1867.40 | 39 | 14.82 | 2673 | 1545 | 1.70 / 246.15 | 2 | 3 |
3 | 13 | 1264.60 | 18 | 14.92 | 1960 | 526 | 2.23 / 246.68 | 2 | 3 |
4 | 13 | 695.56 | 18 | 15.06 | 1257 | 341 | 2.57 / 247.02 | 2 | 4 |
5 | 13 | 268.84 | 18 | 15.17 | 698 | 191 | 2.76 / 247.21 | 2 | 4 |
6 | 8 | -0.16 | 165 | 15.19 | 328 | 822 | 3.58 / 248.03 | 2 | 7 |
7 | 14 | -0.16 | 30 | 15.17 | 321 | 146 | 3.73 / 248.18 | 2 | 7 |
Average= | 2.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 24 | 15.19 | 438 | 160 | 0.16 / 241.11 | 2 | 2 |
2 | 3 | 980.96 | -1 | 15.50 | 0 | 0 | 0.00 / 241.11 | 2 | 2 |
3 | 7 | 1862.56 | 38 | 14.83 | 2662 | 1500 | 1.66 / 242.61 | 2 | 3 |
4 | 13 | 1257.60 | 18 | 14.93 | 1949 | 524 | 2.18 / 243.14 | 2 | 3 |
5 | 13 | 693.88 | 18 | 15.07 | 1240 | 336 | 2.52 / 243.47 | 2 | 4 |
6 | 13 | 272.52 | 18 | 15.17 | 698 | 191 | 2.71 / 243.66 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.20 | 313 | 785 | 3.50 / 244.45 | 2 | 6 |
Average= | 2.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 24 | 15.17 | 451 | 164 | 0.16 / 237.51 | 2 | 2 |
2 | 7 | 1865.32 | 38 | 14.83 | 2669 | 1504 | 1.67 / 239.01 | 2 | 3 |
3 | 13 | 1262.68 | 18 | 14.94 | 1964 | 528 | 2.20 / 239.54 | 2 | 3 |
4 | 13 | 678.44 | 18 | 15.07 | 1225 | 332 | 2.53 / 239.87 | 2 | 4 |
5 | 13 | 252.48 | 18 | 15.18 | 651 | 178 | 2.71 / 240.05 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.20 | 305 | 765 | 3.47 / 240.82 | 2 | 9 |
7 | 14 | 0.20 | 30 | 15.18 | 299 | 136 | 3.61 / 240.95 | 3 | 7 |
Average= | 2.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 24 | 15.18 | 435 | 158 | 0.16 / 234.02 | 2 | 2 |
2 | 7 | 1868.16 | 39 | 14.82 | 2660 | 1537 | 1.70 / 235.56 | 2 | 3 |
3 | 13 | 1138.32 | 18 | 14.98 | 1800 | 485 | 2.18 / 236.04 | 2 | 3 |
4 | 13 | 718.24 | 18 | 15.06 | 1276 | 346 | 2.53 / 236.39 | 2 | 4 |
5 | 13 | 287.20 | 18 | 15.18 | 699 | 191 | 2.72 / 236.58 | 2 | 4 |
6 | 8 | -0.16 | 165 | 15.21 | 305 | 765 | 3.48 / 237.35 | 2 | 8 |
Average= | 2.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 24 | 15.18 | 455 | 166 | 0.17 / 230.48 | 2 | 2 |
2 | 7 | 1865.32 | 38 | 14.84 | 2668 | 1505 | 1.67 / 231.99 | 2 | 3 |
3 | 13 | 1136.04 | 18 | 14.97 | 1806 | 487 | 2.16 / 232.48 | 2 | 3 |
4 | 13 | 713.68 | 18 | 15.07 | 1277 | 346 | 2.50 / 232.82 | 2 | 4 |
5 | 13 | 160.24 | 18 | 15.23 | 525 | 144 | 2.65 / 232.97 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.21 | 303 | 760 | 3.41 / 233.73 | 2 | 5 |
7 | 14 | 0.08 | 30 | 15.19 | 297 | 135 | 3.54 / 233.86 | 3 | 9 |
Average= | 2.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 24 | 15.19 | 433 | 158 | 0.16 / 227.00 | 2 | 2 |
2 | 7 | 1863.64 | 38 | 14.82 | 2655 | 1495 | 1.65 / 228.50 | 2 | 3 |
3 | 13 | 1162.80 | 18 | 14.97 | 1835 | 494 | 2.15 / 228.99 | 2 | 3 |
4 | 13 | 738.44 | 18 | 15.04 | 1332 | 361 | 2.51 / 229.35 | 2 | 4 |
5 | 13 | 310.72 | 18 | 15.17 | 734 | 200 | 2.71 / 229.55 | 2 | 4 |
6 | 8 | 0.00 | 165 | 15.20 | 306 | 767 | 3.48 / 230.32 | 2 | 8 |
Average= | 2.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 24 | 15.19 | 453 | 165 | 0.17 / 223.57 | 2 | 2 |
2 | 7 | 1866.24 | 38 | 14.83 | 2663 | 1501 | 1.67 / 225.08 | 2 | 3 |
3 | 13 | 1258.52 | 18 | 14.95 | 1954 | 526 | 2.19 / 225.60 | 2 | 3 |
4 | 13 | 684.40 | 18 | 15.08 | 1241 | 337 | 2.53 / 225.94 | 2 | 4 |
5 | 13 | 143.44 | 18 | 15.22 | 509 | 139 | 2.67 / 226.08 | 2 | 4 |
6 | 8 | 0.20 | 165 | 15.22 | 305 | 766 | 3.43 / 226.84 | 2 | 11 |
Average= | 2.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 24 | 15.20 | 445 | 162 | 0.16 / 220.02 | 2 | 2 |
2 | 3 | 1016.56 | 1 | 15.20 | 1703 | 26 | 0.19 / 220.05 | 2 | 3 |
3 | 7 | 1862.40 | 38 | 14.84 | 2658 | 1499 | 1.69 / 221.55 | 2 | 3 |
4 | 13 | 1253.52 | 18 | 14.96 | 1955 | 526 | 2.21 / 222.07 | 2 | 3 |
5 | 13 | 799.68 | 18 | 15.04 | 1378 | 373 | 2.59 / 222.44 | 2 | 4 |
6 | 13 | 215.32 | 18 | 15.21 | 626 | 171 | 2.76 / 222.62 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.21 | 316 | 793 | 3.55 / 223.41 | 2 | 10 |
Average= | 2.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 24 | 15.20 | 435 | 159 | 0.16 / 216.58 | 2 | 2 |
2 | 7 | 1863.80 | 38 | 14.85 | 2660 | 1501 | 1.66 / 218.08 | 2 | 3 |
3 | 13 | 1260.20 | 18 | 14.96 | 1947 | 524 | 2.18 / 218.61 | 2 | 3 |
4 | 13 | 699.48 | 18 | 15.08 | 1261 | 342 | 2.53 / 218.95 | 2 | 4 |
5 | 13 | 147.48 | 18 | 15.23 | 510 | 140 | 2.67 / 219.09 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.22 | 307 | 771 | 3.44 / 219.86 | 2 | 6 |
Average= | 2.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 25 | 15.19 | 454 | 172 | 0.17 / 213.09 | 2 | 2 |
2 | 3 | 964.64 | -1 | 15.51 | 0 | 0 | 0.00 / 213.09 | 2 | 2 |
3 | 7 | 1866.12 | 38 | 14.84 | 2673 | 1507 | 1.68 / 214.60 | 2 | 3 |
4 | 13 | 1115.56 | 18 | 15.01 | 1781 | 481 | 2.16 / 215.08 | 2 | 3 |
5 | 13 | 695.80 | 18 | 15.09 | 1253 | 340 | 2.50 / 215.42 | 2 | 4 |
6 | 13 | 140.72 | 18 | 15.24 | 503 | 138 | 2.64 / 215.56 | 2 | 4 |
7 | 13 | 31.68 | 18 | 15.26 | 351 | 96 | 2.74 / 215.66 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.22 | 304 | 763 | 3.50 / 216.42 | 2 | 9 |
Average= | 2.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 24 | 15.20 | 447 | 163 | 0.16 / 209.48 | 2 | 2 |
2 | 3 | 1019.48 | 1 | 15.18 | 1708 | 26 | 0.19 / 209.50 | 2 | 2 |
3 | 7 | 1861.68 | 39 | 14.83 | 2665 | 1541 | 1.73 / 211.05 | 2 | 3 |
4 | 13 | 1140.48 | 18 | 14.98 | 1817 | 490 | 2.22 / 211.54 | 2 | 3 |
5 | 13 | 716.96 | 18 | 15.07 | 1286 | 349 | 2.57 / 211.88 | 2 | 4 |
6 | 13 | 159.96 | 18 | 15.23 | 541 | 148 | 2.72 / 212.03 | 2 | 4 |
7 | 13 | 34.28 | 18 | 15.26 | 366 | 101 | 2.82 / 212.13 | 2 | 4 |
8 | 8 | 0.12 | 165 | 15.22 | 314 | 789 | 3.61 / 212.92 | 2 | 6 |
Average= | 2.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 24 | 15.19 | 453 | 165 | 0.17 / 205.92 | 2 | 2 |
2 | 7 | 1867.08 | 39 | 14.84 | 2661 | 1540 | 1.71 / 207.46 | 2 | 3 |
3 | 13 | 1130.04 | 18 | 14.99 | 1815 | 490 | 2.19 / 207.95 | 2 | 3 |
4 | 13 | 705.48 | 18 | 15.09 | 1269 | 345 | 2.54 / 208.29 | 2 | 4 |
5 | 13 | 150.44 | 18 | 15.24 | 519 | 142 | 2.68 / 208.44 | 2 | 4 |
6 | 13 | 32.28 | 18 | 15.26 | 364 | 100 | 2.78 / 208.54 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.21 | 311 | 781 | 3.56 / 209.32 | 2 | 9 |
Average= | 2.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 25 | 15.19 | 441 | 167 | 0.17 / 202.37 | 2 | 2 |
2 | 3 | 975.20 | -1 | 15.53 | 0 | 0 | 0.00 / 202.37 | 2 | 2 |
3 | 3 | 1019.16 | 1 | 15.23 | 1704 | 26 | 0.19 / 202.40 | 2 | 3 |
4 | 7 | 1863.32 | 38 | 14.84 | 2663 | 1502 | 1.70 / 203.90 | 2 | 3 |
5 | 13 | 1132.40 | 18 | 15.00 | 1796 | 485 | 2.18 / 204.38 | 2 | 3 |
6 | 13 | 708.52 | 18 | 15.09 | 1277 | 347 | 2.53 / 204.73 | 2 | 4 |
7 | 13 | 143.28 | 18 | 15.25 | 510 | 140 | 2.67 / 204.87 | 2 | 4 |
8 | 13 | 31.00 | 18 | 15.27 | 354 | 97 | 2.76 / 204.97 | 2 | 3 |
9 | 8 | -0.08 | 165 | 15.22 | 313 | 786 | 3.55 / 205.75 | 2 | 8 |
Average= | 2.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 25 | 15.20 | 445 | 169 | 0.17 / 198.82 | 2 | 2 |
2 | 3 | 973.40 | -1 | 15.53 | 0 | 0 | 0.00 / 198.82 | 2 | 2 |
3 | 7 | 1863.56 | 38 | 14.85 | 2658 | 1500 | 1.67 / 200.32 | 2 | 3 |
4 | 13 | 1130.48 | 18 | 15.01 | 1800 | 486 | 2.16 / 200.81 | 2 | 3 |
5 | 13 | 708.48 | 18 | 15.10 | 1276 | 347 | 2.50 / 201.16 | 2 | 4 |
6 | 13 | 257.08 | 18 | 15.22 | 666 | 182 | 2.68 / 201.34 | 2 | 4 |
7 | 13 | 23.16 | 18 | 15.28 | 349 | 96 | 2.78 / 201.44 | 2 | 4 |
8 | 8 | -0.08 | 165 | 15.23 | 305 | 766 | 3.55 / 202.20 | 2 | 9 |
Average= | 2.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 25 | 15.20 | 446 | 169 | 0.17 / 195.34 | 2 | 2 |
2 | 7 | 1862.88 | 38 | 14.84 | 2653 | 1496 | 1.67 / 196.84 | 2 | 3 |
3 | 13 | 1113.68 | 18 | 15.00 | 1772 | 478 | 2.14 / 197.32 | 2 | 3 |
4 | 13 | 695.64 | 18 | 15.10 | 1253 | 341 | 2.48 / 197.66 | 2 | 4 |
5 | 13 | 142.20 | 18 | 15.26 | 505 | 139 | 2.62 / 197.80 | 2 | 4 |
6 | 13 | 32.72 | 18 | 15.27 | 356 | 98 | 2.72 / 197.89 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.24 | 303 | 762 | 3.48 / 198.66 | 2 | 8 |
Average= | 2.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 24 | 15.20 | 443 | 162 | 0.16 / 191.69 | 2 | 2 |
2 | 3 | 1037.32 | 1 | 15.20 | 1731 | 26 | 0.19 / 191.71 | 2 | 3 |
3 | 3 | 1016.36 | 1 | 15.23 | 1696 | 26 | 0.21 / 191.74 | 2 | 3 |
4 | 7 | 1867.56 | 38 | 14.85 | 2672 | 1508 | 1.72 / 193.25 | 2 | 3 |
5 | 13 | 1252.84 | 18 | 14.97 | 1946 | 524 | 2.25 / 193.77 | 2 | 3 |
6 | 13 | 689.92 | 18 | 15.10 | 1238 | 336 | 2.58 / 194.11 | 2 | 4 |
7 | 13 | 272.40 | 18 | 15.22 | 700 | 192 | 2.77 / 194.30 | 2 | 4 |
8 | 13 | 29.88 | 18 | 15.28 | 358 | 98 | 2.87 / 194.40 | 2 | 4 |
9 | 8 | 0.00 | 165 | 15.23 | 308 | 774 | 3.65 / 195.17 | 2 | 8 |
Average= | 2.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.76 | 24 | 15.22 | 437 | 160 | 0.16 / 188.18 | 2 | 2 |
2 | 7 | 1863.16 | 39 | 14.85 | 2658 | 1539 | 1.70 / 189.72 | 2 | 3 |
3 | 13 | 1131.32 | 18 | 15.02 | 1793 | 485 | 2.18 / 190.21 | 2 | 3 |
4 | 13 | 703.60 | 18 | 15.10 | 1253 | 341 | 2.52 / 190.55 | 2 | 4 |
5 | 13 | 149.12 | 18 | 15.26 | 503 | 138 | 2.66 / 190.68 | 2 | 3 |
6 | 13 | 33.12 | 18 | 15.28 | 346 | 95 | 2.76 / 190.78 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.24 | 297 | 747 | 3.50 / 191.53 | 2 | 10 |
Average= | 2.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 24 | 15.24 | 452 | 165 | 0.17 / 184.60 | 2 | 2 |
2 | 10 | 1014.28 | 2 | 15.19 | 1685 | 51 | 0.22 / 184.65 | 2 | 2 |
3 | 3 | 976.32 | -1 | 15.54 | 0 | 0 | 0.05 / 184.65 | 2 | 2 |
4 | 7 | 1867.24 | 38 | 14.85 | 2664 | 1503 | 1.72 / 186.15 | 2 | 3 |
5 | 13 | 1142.64 | 18 | 15.02 | 1801 | 487 | 2.21 / 186.64 | 2 | 3 |
6 | 13 | 722.60 | 18 | 15.09 | 1285 | 349 | 2.56 / 186.99 | 2 | 4 |
7 | 13 | 276.48 | 18 | 15.23 | 678 | 186 | 2.74 / 187.17 | 2 | 4 |
8 | 13 | 26.44 | 18 | 15.28 | 344 | 95 | 2.84 / 187.27 | 2 | 4 |
9 | 8 | 0.04 | 165 | 15.24 | 300 | 754 | 3.59 / 188.02 | 2 | 9 |
Average= | 2.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 24 | 15.24 | 438 | 160 | 0.16 / 181.04 | 2 | 2 |
2 | 7 | 1863.36 | 38 | 14.85 | 2653 | 1497 | 1.66 / 182.54 | 2 | 3 |
3 | 13 | 1249.76 | 18 | 14.99 | 1945 | 525 | 2.18 / 183.06 | 2 | 3 |
4 | 13 | 789.68 | 18 | 15.08 | 1375 | 373 | 2.56 / 183.44 | 2 | 4 |
5 | 13 | 197.12 | 18 | 15.26 | 576 | 158 | 2.71 / 183.60 | 2 | 4 |
6 | 13 | 19.64 | 18 | 15.30 | 324 | 89 | 2.80 / 183.69 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.26 | 296 | 745 | 3.55 / 184.43 | 2 | 6 |
Average= | 1.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 24 | 15.23 | 423 | 155 | 0.15 / 177.55 | 2 | 2 |
2 | 7 | 1861.76 | 38 | 14.86 | 2642 | 1492 | 1.65 / 179.04 | 2 | 3 |
3 | 13 | 1120.96 | 18 | 15.02 | 1793 | 485 | 2.13 / 179.52 | 2 | 3 |
4 | 13 | 701.72 | 18 | 15.12 | 1257 | 342 | 2.47 / 179.86 | 2 | 4 |
5 | 13 | 268.20 | 18 | 15.24 | 668 | 183 | 2.66 / 180.05 | 2 | 4 |
6 | 13 | 22.08 | 18 | 15.30 | 328 | 90 | 2.75 / 180.14 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.25 | 296 | 745 | 3.49 / 180.88 | 2 | 9 |
Average= | 1.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 24 | 15.25 | 442 | 162 | 0.16 / 174.10 | 2 | 2 |
2 | 7 | 1864.68 | 38 | 14.86 | 2658 | 1501 | 1.66 / 175.60 | 2 | 3 |
3 | 13 | 1142.04 | 18 | 15.03 | 1805 | 488 | 2.15 / 176.09 | 2 | 3 |
4 | 13 | 604.32 | 18 | 15.15 | 1123 | 306 | 2.46 / 176.40 | 2 | 4 |
5 | 13 | 195.04 | 18 | 15.26 | 567 | 156 | 2.61 / 176.55 | 2 | 3 |
6 | 13 | 17.44 | 18 | 15.30 | 325 | 90 | 2.70 / 176.64 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.26 | 298 | 750 | 3.45 / 177.39 | 2 | 8 |
Average= | 1.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 23 | 15.23 | 447 | 157 | 0.16 / 170.64 | 2 | 2 |
2 | 3 | 1029.96 | 1 | 15.21 | 1687 | 26 | 0.18 / 170.67 | 2 | 3 |
3 | 3 | 1016.12 | 1 | 15.24 | 1697 | 26 | 0.21 / 170.70 | 2 | 3 |
4 | 7 | 1865.16 | 38 | 14.88 | 2656 | 1502 | 1.71 / 172.20 | 2 | 3 |
5 | 13 | 1148.40 | 18 | 15.04 | 1806 | 489 | 2.20 / 172.69 | 2 | 3 |
6 | 13 | 725.56 | 18 | 15.13 | 1283 | 349 | 2.55 / 173.04 | 2 | 4 |
7 | 13 | 161.60 | 18 | 15.28 | 524 | 144 | 2.69 / 173.18 | 2 | 4 |
8 | 8 | 0.20 | 165 | 15.27 | 301 | 758 | 3.45 / 173.94 | 2 | 7 |
Average= | 1.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 23 | 15.25 | 450 | 158 | 0.16 / 167.21 | 2 | 2 |
2 | 7 | 1861.76 | 38 | 14.87 | 2651 | 1498 | 1.66 / 168.71 | 2 | 3 |
3 | 13 | 1240.00 | 18 | 15.01 | 1918 | 518 | 2.17 / 169.22 | 2 | 3 |
4 | 13 | 786.92 | 18 | 15.11 | 1357 | 369 | 2.54 / 169.59 | 2 | 4 |
5 | 13 | 190.52 | 18 | 15.28 | 552 | 152 | 2.69 / 169.74 | 2 | 4 |
6 | 8 | 0.16 | 165 | 15.27 | 295 | 743 | 3.44 / 170.49 | 2 | 7 |
Average= | 1.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 22 | 15.25 | 440 | 148 | 0.15 / 163.75 | 2 | 2 |
2 | 3 | 1016.60 | 1 | 15.23 | 1688 | 26 | 0.17 / 163.78 | 2 | 3 |
3 | 7 | 1863.08 | 38 | 14.87 | 2662 | 1504 | 1.68 / 165.28 | 2 | 3 |
4 | 13 | 1252.84 | 18 | 15.01 | 1959 | 529 | 2.21 / 165.81 | 2 | 3 |
5 | 13 | 679.68 | 18 | 15.15 | 1219 | 332 | 2.54 / 166.14 | 2 | 4 |
6 | 13 | 148.12 | 18 | 15.28 | 504 | 139 | 2.68 / 166.28 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.28 | 305 | 769 | 3.45 / 167.05 | 2 | 6 |
Average= | 1.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 23 | 15.25 | 439 | 154 | 0.15 / 160.26 | 2 | 2 |
2 | 3 | 980.64 | -1 | 15.57 | 0 | 0 | 0.00 / 160.26 | 2 | 2 |
3 | 3 | 1019.72 | 1 | 15.25 | 1687 | 26 | 0.18 / 160.29 | 2 | 3 |
4 | 7 | 1863.40 | 38 | 14.88 | 2665 | 1507 | 1.69 / 161.79 | 2 | 3 |
5 | 13 | 1262.88 | 18 | 15.01 | 1952 | 527 | 2.21 / 162.32 | 2 | 3 |
6 | 13 | 691.56 | 18 | 15.13 | 1238 | 337 | 2.55 / 162.66 | 2 | 4 |
7 | 13 | 258.24 | 18 | 15.26 | 658 | 181 | 2.73 / 162.84 | 2 | 4 |
8 | 8 | 0.28 | 165 | 15.28 | 303 | 764 | 3.50 / 163.60 | 2 | 7 |
Average= | 1.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 22 | 15.26 | 433 | 145 | 0.15 / 156.80 | 2 | 2 |
2 | 10 | 1000.60 | 2 | 15.22 | 1662 | 51 | 0.20 / 156.85 | 2 | 3 |
3 | 3 | 961.80 | -1 | 15.55 | 0 | 0 | 0.05 / 156.85 | 2 | 3 |
4 | 7 | 1861.84 | 38 | 14.88 | 2661 | 1505 | 1.70 / 158.35 | 2 | 3 |
5 | 13 | 1262.92 | 18 | 15.01 | 1954 | 528 | 2.23 / 158.88 | 2 | 3 |
6 | 13 | 689.60 | 18 | 15.15 | 1230 | 335 | 2.56 / 159.22 | 2 | 4 |
7 | 13 | 140.32 | 18 | 15.30 | 492 | 135 | 2.70 / 159.35 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.29 | 299 | 754 | 3.45 / 160.11 | 2 | 7 |
Average= | 1.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 22 | 15.27 | 436 | 146 | 0.15 / 153.44 | 2 | 2 |
2 | 7 | 1862.84 | 38 | 14.88 | 2650 | 1498 | 1.64 / 154.93 | 2 | 3 |
3 | 13 | 1145.04 | 18 | 15.05 | 1799 | 487 | 2.13 / 155.42 | 2 | 3 |
4 | 13 | 724.00 | 18 | 15.15 | 1266 | 345 | 2.48 / 155.77 | 2 | 4 |
5 | 13 | 160.60 | 18 | 15.29 | 520 | 143 | 2.62 / 155.91 | 2 | 3 |
6 | 8 | 0.36 | 165 | 15.28 | 295 | 744 | 3.36 / 156.65 | 2 | 8 |
Average= | 1.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 22 | 15.27 | 441 | 148 | 0.15 / 150.02 | 2 | 2 |
2 | 3 | 1020.04 | 1 | 15.25 | 1690 | 26 | 0.17 / 150.05 | 2 | 2 |
3 | 7 | 1862.92 | 38 | 14.89 | 2646 | 1497 | 1.67 / 151.54 | 2 | 3 |
4 | 13 | 1261.92 | 18 | 15.03 | 1938 | 524 | 2.20 / 152.07 | 2 | 3 |
5 | 13 | 695.36 | 18 | 15.16 | 1237 | 338 | 2.53 / 152.41 | 2 | 4 |
6 | 13 | 150.00 | 18 | 15.30 | 495 | 136 | 2.67 / 152.54 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.30 | 296 | 747 | 3.42 / 153.29 | 2 | 6 |
Average= | 1.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 22 | 15.28 | 433 | 146 | 0.15 / 146.70 | 2 | 2 |
2 | 7 | 1864.40 | 38 | 14.88 | 2643 | 1494 | 1.64 / 148.19 | 2 | 3 |
3 | 13 | 1125.00 | 18 | 15.05 | 1782 | 483 | 2.12 / 148.67 | 2 | 3 |
4 | 13 | 708.44 | 18 | 15.14 | 1246 | 340 | 2.46 / 149.01 | 2 | 4 |
5 | 13 | 156.00 | 18 | 15.29 | 498 | 137 | 2.60 / 149.15 | 2 | 3 |
6 | 8 | 0.36 | 165 | 15.29 | 286 | 722 | 3.32 / 149.87 | 2 | 6 |
Average= | 1.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 22 | 15.27 | 426 | 143 | 0.14 / 143.34 | 2 | 2 |
2 | 3 | 978.16 | -1 | 15.57 | 0 | 0 | 0.00 / 143.34 | 2 | 2 |
3 | 7 | 1871.52 | 38 | 14.89 | 2663 | 1507 | 1.65 / 144.85 | 2 | 3 |
4 | 13 | 1140.92 | 18 | 15.06 | 1788 | 485 | 2.13 / 145.33 | 2 | 3 |
5 | 13 | 727.00 | 18 | 15.15 | 1271 | 347 | 2.48 / 145.68 | 2 | 4 |
6 | 13 | 167.28 | 18 | 15.29 | 518 | 143 | 2.62 / 145.82 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.30 | 288 | 727 | 3.35 / 146.55 | 2 | 6 |
Average= | 1.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 21 | 15.25 | 451 | 144 | 0.14 / 139.95 | 2 | 2 |
2 | 3 | 1033.72 | 1 | 15.21 | 1695 | 26 | 0.17 / 139.97 | 2 | 3 |
3 | 7 | 1861.80 | 38 | 14.91 | 2635 | 1493 | 1.66 / 141.47 | 2 | 3 |
4 | 13 | 1241.96 | 18 | 15.03 | 1912 | 517 | 2.18 / 141.98 | 2 | 3 |
5 | 13 | 666.36 | 18 | 15.18 | 1190 | 325 | 2.51 / 142.31 | 2 | 4 |
6 | 13 | 236.48 | 18 | 15.28 | 614 | 169 | 2.67 / 142.48 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.30 | 286 | 722 | 3.40 / 143.20 | 2 | 6 |
Average= | 1.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 22 | 15.37 | 413 | 140 | 0.14 / 136.53 | 2 | 2 |
2 | 3 | 967.80 | -1 | 15.59 | 0 | 0 | 0.00 / 136.53 | 2 | 2 |
3 | 7 | 1863.60 | 38 | 14.90 | 2635 | 1492 | 1.63 / 138.02 | 2 | 3 |
4 | 13 | 1257.84 | 18 | 15.03 | 1923 | 520 | 2.15 / 138.54 | 2 | 3 |
5 | 13 | 805.52 | 18 | 15.12 | 1357 | 369 | 2.52 / 138.91 | 2 | 4 |
6 | 13 | 211.60 | 18 | 15.28 | 576 | 158 | 2.68 / 139.07 | 2 | 4 |
7 | 8 | 0.20 | 165 | 15.29 | 290 | 732 | 3.41 / 139.80 | 2 | 7 |
Average= | 1.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 38 | 15.35 | 418 | 244 | 0.24 / 135.15 | 2 | 2 |
2 | 7 | 512.64 | 38 | 15.35 | 942 | 549 | 0.79 / 135.70 | 2 | 3 |
3 | 8 | 0.00 | 165 | 15.40 | 274 | 696 | 1.49 / 136.39 | 2 | 6 |
Average= | 1.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 38 | 15.36 | 401 | 234 | 0.23 / 133.55 | 2 | 2 |
2 | 3 | 461.32 | -1 | 15.55 | 0 | 0 | 0.00 / 133.55 | 2 | 2 |
3 | 7 | 531.72 | 38 | 15.34 | 963 | 561 | 0.80 / 134.11 | 2 | 3 |
4 | 8 | 0.16 | 165 | 15.40 | 263 | 668 | 1.46 / 134.78 | 2 | 5 |
5 | 14 | 0.16 | 30 | 15.38 | 265 | 122 | 1.59 / 134.90 | 2 | 8 |
Average= | 1.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 38 | 15.36 | 404 | 236 | 0.24 / 131.99 | 2 | 2 |
2 | 7 | 495.00 | 39 | 15.36 | 912 | 546 | 0.78 / 132.53 | 2 | 3 |
3 | 8 | 0.04 | 165 | 15.40 | 262 | 666 | 1.45 / 133.20 | 3 | 6 |
4 | 14 | 0.04 | 30 | 15.39 | 260 | 120 | 1.57 / 133.32 | 2 | 8 |
Average= | 1.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 38 | 15.36 | 406 | 237 | 0.24 / 130.54 | 2 | 3 |
2 | 7 | 508.44 | 38 | 15.35 | 932 | 544 | 0.78 / 131.08 | 2 | 3 |
3 | 8 | 0.04 | 165 | 15.40 | 262 | 666 | 1.45 / 131.75 | 2 | 7 |
Average= | 1.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 38 | 15.35 | 400 | 233 | 0.23 / 129.07 | 2 | 3 |
2 | 3 | 472.16 | -1 | 15.55 | 0 | 0 | 0.00 / 129.07 | 2 | 3 |
3 | 7 | 525.96 | 38 | 15.35 | 956 | 558 | 0.79 / 129.63 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.40 | 265 | 673 | 1.46 / 130.30 | 2 | 4 |
Average= | 1.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 38 | 15.35 | 424 | 247 | 0.25 / 127.50 | 2 | 2 |
2 | 7 | 514.32 | 38 | 15.35 | 944 | 551 | 0.80 / 128.05 | 2 | 3 |
3 | 8 | 0.20 | 165 | 15.40 | 265 | 673 | 1.47 / 128.72 | 2 | 5 |
4 | 14 | 0.20 | 30 | 15.38 | 259 | 120 | 1.59 / 128.84 | 2 | 6 |
Average= | 1.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 38 | 15.34 | 399 | 233 | 0.23 / 126.02 | 2 | 2 |
2 | 7 | 501.28 | 38 | 15.36 | 925 | 540 | 0.77 / 126.56 | 2 | 3 |
3 | 8 | 0.12 | 165 | 15.41 | 271 | 689 | 1.46 / 127.25 | 2 | 6 |
Average= | 1.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 38 | 15.36 | 407 | 238 | 0.24 / 124.55 | 2 | 2 |
2 | 3 | 472.20 | -1 | 15.55 | 0 | 0 | 0.00 / 124.55 | 2 | 2 |
3 | 7 | 531.52 | 38 | 15.34 | 970 | 565 | 0.80 / 125.11 | 2 | 3 |
4 | 8 | 0.20 | 165 | 15.40 | 265 | 673 | 1.48 / 125.79 | 2 | 4 |
Average= | 1.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 38 | 15.36 | 399 | 233 | 0.23 / 123.08 | 2 | 2 |
2 | 7 | 519.48 | 38 | 15.35 | 950 | 554 | 0.79 / 123.64 | 2 | 3 |
3 | 8 | 0.20 | 165 | 15.40 | 264 | 671 | 1.46 / 124.31 | 2 | 6 |
Average= | 1.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 38 | 15.35 | 416 | 243 | 0.24 / 121.60 | 2 | 2 |
2 | 3 | 469.60 | -1 | 15.56 | 0 | 0 | 0.00 / 121.60 | 2 | 2 |
3 | 7 | 520.48 | 38 | 15.36 | 958 | 559 | 0.80 / 122.16 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.41 | 272 | 692 | 1.49 / 122.85 | 2 | 7 |
Average= | 1.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 38 | 15.38 | 397 | 232 | 0.23 / 119.97 | 2 | 2 |
2 | 3 | 477.36 | -1 | 15.56 | 0 | 0 | 0.00 / 119.97 | 2 | 2 |
3 | 7 | 530.92 | 38 | 15.36 | 959 | 560 | 0.79 / 120.53 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.41 | 278 | 707 | 1.50 / 121.23 | 2 | 4 |
5 | 14 | 0.04 | 30 | 15.39 | 273 | 126 | 1.62 / 121.36 | 2 | 8 |
Average= | 1.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 38 | 15.37 | 403 | 235 | 0.24 / 118.51 | 2 | 3 |
2 | 3 | 482.44 | -1 | 15.56 | 0 | 0 | 0.00 / 118.51 | 2 | 3 |
3 | 7 | 534.16 | 38 | 15.36 | 966 | 564 | 0.80 / 119.08 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.41 | 259 | 659 | 1.46 / 119.73 | 2 | 4 |
Average= | 1.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 38 | 15.36 | 413 | 241 | 0.24 / 117.05 | 2 | 3 |
2 | 3 | 471.72 | -1 | 15.56 | 0 | 0 | 0.00 / 117.05 | 2 | 3 |
3 | 7 | 527.84 | 38 | 15.35 | 961 | 561 | 0.80 / 117.62 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.41 | 260 | 661 | 1.46 / 118.28 | 2 | 8 |
Average= | 1.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 38 | 15.37 | 407 | 238 | 0.24 / 115.56 | 2 | 2 |
2 | 3 | 477.08 | -1 | 15.56 | 0 | 0 | 0.00 / 115.56 | 2 | 2 |
3 | 7 | 534.52 | 38 | 15.35 | 967 | 564 | 0.80 / 116.12 | 2 | 3 |
4 | 8 | 0.16 | 165 | 15.41 | 271 | 689 | 1.49 / 116.81 | 2 | 7 |
Average= | 1.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 38 | 15.37 | 418 | 244 | 0.24 / 114.12 | 2 | 2 |
2 | 7 | 504.44 | 38 | 15.36 | 929 | 542 | 0.79 / 114.66 | 2 | 3 |
3 | 8 | 0.12 | 165 | 15.41 | 260 | 661 | 1.45 / 115.32 | 2 | 5 |
Average= | 1.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 39 | 15.35 | 412 | 247 | 0.25 / 112.61 | 2 | 3 |
2 | 3 | 466.48 | -1 | 15.55 | 0 | 0 | 0.00 / 112.61 | 2 | 3 |
3 | 7 | 527.56 | 39 | 15.36 | 962 | 576 | 0.82 / 113.19 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.41 | 269 | 684 | 1.51 / 113.88 | 2 | 5 |
Average= | 1.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 39 | 15.36 | 404 | 242 | 0.24 / 111.12 | 2 | 2 |
2 | 3 | 481.68 | -1 | 15.55 | 0 | 0 | 0.00 / 111.12 | 2 | 2 |
3 | 7 | 536.16 | 38 | 15.35 | 966 | 563 | 0.81 / 111.68 | 2 | 3 |
4 | 8 | 0.20 | 165 | 15.40 | 270 | 686 | 1.49 / 112.37 | 2 | 6 |
Average= | 1.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 38 | 15.34 | 410 | 239 | 0.24 / 109.65 | 2 | 2 |
2 | 3 | 480.48 | -1 | 15.55 | 0 | 0 | 0.00 / 109.65 | 2 | 2 |
3 | 7 | 545.00 | 38 | 15.35 | 979 | 571 | 0.81 / 110.22 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.40 | 259 | 658 | 1.47 / 110.88 | 2 | 6 |
Average= | 1.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 39 | 15.34 | 414 | 248 | 0.25 / 108.20 | 2 | 2 |
2 | 3 | 451.12 | -1 | 15.54 | 0 | 0 | 0.00 / 108.20 | 2 | 2 |
3 | 7 | 508.36 | 38 | 15.34 | 932 | 543 | 0.79 / 108.74 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.40 | 262 | 666 | 1.46 / 109.41 | 2 | 10 |
Average= | 1.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 38 | 15.28 | 416 | 242 | 0.24 / 106.60 | 2 | 2 |
2 | 3 | 519.16 | 1 | 15.37 | 963 | 15 | 0.26 / 106.61 | 2 | 3 |
3 | 7 | 521.12 | 38 | 15.34 | 954 | 556 | 0.81 / 107.17 | 2 | 3 |
4 | 8 | 0.64 | 165 | 15.39 | 262 | 665 | 1.48 / 107.83 | 2 | 7 |
5 | 14 | 0.64 | 30 | 15.37 | 259 | 119 | 1.60 / 107.95 | 2 | 5 |
Average= | 1.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 22 | 15.37 | 418 | 141 | 0.14 / 102.99 | 2 | 2 |
2 | 3 | 1017.40 | 1 | 15.29 | 1673 | 26 | 0.17 / 103.01 | 2 | 2 |
3 | 7 | 1862.96 | 38 | 14.91 | 2626 | 1488 | 1.65 / 104.50 | 2 | 3 |
4 | 13 | 1242.52 | 18 | 15.05 | 1897 | 514 | 2.17 / 105.02 | 2 | 3 |
5 | 13 | 791.20 | 18 | 15.14 | 1343 | 366 | 2.53 / 105.38 | 2 | 4 |
6 | 13 | 201.52 | 18 | 15.30 | 551 | 152 | 2.69 / 105.53 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.31 | 275 | 695 | 3.38 / 106.23 | 2 | 7 |
8 | 14 | 0.12 | 30 | 15.29 | 274 | 126 | 3.51 / 106.35 | 2 | 8 |
Average= | 1.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 38 | 15.37 | 398 | 232 | 0.23 / 101.63 | 2 | 2 |
2 | 3 | 476.60 | -1 | 15.57 | 0 | 0 | 0.00 / 101.63 | 2 | 2 |
3 | 7 | 537.92 | 38 | 15.36 | 966 | 564 | 0.80 / 102.20 | 2 | 3 |
4 | 8 | 0.16 | 165 | 15.41 | 256 | 651 | 1.45 / 102.85 | 2 | 5 |
Average= | 1.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 38 | 15.37 | 406 | 237 | 0.24 / 100.20 | 2 | 2 |
2 | 3 | 476.48 | -1 | 15.55 | 0 | 0 | 0.00 / 100.20 | 2 | 2 |
3 | 7 | 535.52 | 38 | 15.35 | 960 | 560 | 0.80 / 100.76 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.42 | 253 | 644 | 1.44 / 101.40 | 2 | 4 |
Average= | 1.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 38 | 15.37 | 389 | 227 | 0.23 / 98.75 | 2 | 2 |
2 | 3 | 480.80 | -1 | 15.56 | 0 | 0 | 0.00 / 98.75 | 2 | 2 |
3 | 7 | 553.24 | 38 | 15.35 | 983 | 573 | 0.80 / 99.32 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.41 | 252 | 641 | 1.44 / 99.96 | 2 | 7 |
Average= | 1.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 38 | 15.37 | 407 | 238 | 0.24 / 97.30 | 2 | 2 |
2 | 3 | 478.92 | -1 | 15.56 | 0 | 0 | 0.00 / 97.30 | 2 | 2 |
3 | 7 | 542.92 | 38 | 15.35 | 973 | 568 | 0.81 / 97.87 | 2 | 3 |
4 | 8 | -0.04 | 165 | 15.42 | 254 | 646 | 1.45 / 98.52 | 2 | 6 |
Average= | 1.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 38 | 15.36 | 387 | 226 | 0.23 / 95.85 | 2 | 2 |
2 | 3 | 463.72 | -1 | 15.55 | 0 | 0 | 0.00 / 95.85 | 2 | 2 |
3 | 7 | 526.36 | 39 | 15.36 | 949 | 568 | 0.79 / 96.42 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.41 | 256 | 651 | 1.45 / 97.07 | 2 | 6 |
Average= | 1.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 38 | 15.38 | 402 | 235 | 0.23 / 94.31 | 2 | 2 |
2 | 3 | 476.68 | -1 | 15.57 | 0 | 0 | 0.00 / 94.31 | 2 | 2 |
3 | 7 | 531.68 | 38 | 15.36 | 956 | 558 | 0.79 / 94.87 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.41 | 252 | 641 | 1.43 / 95.51 | 2 | 7 |
5 | 14 | 0.12 | 30 | 15.40 | 251 | 116 | 1.55 / 95.62 | 3 | 6 |
Average= | 1.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 38 | 15.37 | 398 | 232 | 0.23 / 92.86 | 2 | 2 |
2 | 3 | 479.88 | -1 | 15.55 | 0 | 0 | 0.00 / 92.86 | 2 | 2 |
3 | 7 | 531.28 | 38 | 15.36 | 958 | 559 | 0.79 / 93.42 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.41 | 257 | 653 | 1.45 / 94.07 | 2 | 7 |
Average= | 1.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 38 | 15.37 | 393 | 230 | 0.23 / 91.43 | 2 | 3 |
2 | 3 | 466.76 | -1 | 15.56 | 0 | 0 | 0.00 / 91.43 | 2 | 3 |
3 | 7 | 523.00 | 38 | 15.37 | 944 | 551 | 0.78 / 91.99 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.42 | 252 | 641 | 1.42 / 92.63 | 2 | 6 |
Average= | 1.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 38 | 15.37 | 405 | 237 | 0.24 / 90.01 | 2 | 2 |
2 | 7 | 523.00 | 38 | 15.37 | 947 | 553 | 0.79 / 90.57 | 2 | 3 |
3 | 8 | 0.08 | 165 | 15.42 | 251 | 639 | 1.43 / 91.21 | 2 | 6 |
Average= | 1.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 38 | 15.38 | 392 | 229 | 0.23 / 88.48 | 2 | 2 |
2 | 7 | 506.92 | 38 | 15.37 | 926 | 541 | 0.77 / 89.02 | 2 | 3 |
3 | 8 | 0.24 | 165 | 15.42 | 252 | 641 | 1.41 / 89.66 | 2 | 8 |
4 | 14 | 0.24 | 30 | 15.40 | 252 | 116 | 1.53 / 89.78 | 3 | 8 |
Average= | 1.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 38 | 15.38 | 387 | 226 | 0.23 / 87.05 | 2 | 2 |
2 | 3 | 470.44 | -1 | 15.57 | 0 | 0 | 0.00 / 87.05 | 2 | 2 |
3 | 7 | 526.04 | 38 | 15.36 | 951 | 555 | 0.78 / 87.60 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.42 | 254 | 646 | 1.43 / 88.25 | 2 | 5 |
Average= | 1.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 38 | 15.36 | 392 | 229 | 0.23 / 85.52 | 2 | 2 |
2 | 3 | 455.52 | -1 | 15.56 | 0 | 0 | 0.00 / 85.52 | 2 | 2 |
3 | 7 | 519.24 | 38 | 15.38 | 937 | 548 | 0.78 / 86.07 | 2 | 3 |
4 | 8 | 0.20 | 165 | 15.42 | 250 | 636 | 1.41 / 86.71 | 2 | 6 |
5 | 14 | 0.20 | 30 | 15.41 | 249 | 115 | 1.53 / 86.82 | 2 | 9 |
Average= | 1.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 38 | 15.39 | 396 | 232 | 0.23 / 83.98 | 2 | 2 |
2 | 7 | 523.32 | 38 | 15.36 | 948 | 553 | 0.78 / 84.54 | 2 | 3 |
3 | 8 | 0.12 | 165 | 15.42 | 252 | 641 | 1.43 / 85.18 | 2 | 7 |
4 | 14 | 0.12 | 30 | 15.39 | 250 | 115 | 1.54 / 85.29 | 2 | 6 |
Average= | 1.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 38 | 15.38 | 401 | 234 | 0.23 / 82.57 | 2 | 2 |
2 | 7 | 510.44 | 38 | 15.38 | 929 | 543 | 0.78 / 83.11 | 2 | 3 |
3 | 8 | 0.20 | 165 | 15.43 | 251 | 639 | 1.42 / 83.75 | 2 | 5 |
Average= | 1.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 38 | 15.39 | 392 | 229 | 0.23 / 81.15 | 2 | 2 |
2 | 7 | 523.92 | 38 | 15.37 | 946 | 553 | 0.78 / 81.70 | 2 | 3 |
3 | 8 | 0.08 | 165 | 15.42 | 251 | 639 | 1.42 / 82.34 | 2 | 8 |
Average= | 1.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 38 | 15.37 | 398 | 232 | 0.23 / 79.74 | 2 | 2 |
2 | 7 | 500.04 | 38 | 15.38 | 915 | 535 | 0.77 / 80.27 | 2 | 3 |
3 | 8 | 0.24 | 165 | 15.43 | 252 | 642 | 1.41 / 80.92 | 2 | 7 |
Average= | 1.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 38 | 15.39 | 388 | 227 | 0.23 / 78.18 | 2 | 2 |
2 | 3 | 477.92 | -1 | 15.57 | 0 | 0 | 0.00 / 78.18 | 2 | 2 |
3 | 7 | 543.24 | 38 | 15.37 | 974 | 569 | 0.80 / 78.75 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.43 | 252 | 642 | 1.44 / 79.39 | 2 | 7 |
5 | 14 | 0.08 | 30 | 15.40 | 253 | 117 | 1.55 / 79.51 | 2 | 9 |
Average= | 1.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 38 | 15.39 | 384 | 225 | 0.22 / 76.66 | 2 | 2 |
2 | 3 | 454.64 | -1 | 15.58 | 0 | 0 | 0.00 / 76.66 | 2 | 2 |
3 | 7 | 503.88 | 38 | 15.39 | 918 | 537 | 0.76 / 77.20 | 2 | 3 |
4 | 8 | 0.16 | 165 | 15.44 | 251 | 639 | 1.40 / 77.84 | 2 | 4 |
5 | 14 | 0.16 | 30 | 15.42 | 252 | 117 | 1.52 / 77.95 | 2 | 5 |
Average= | 1.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 39 | 15.38 | 401 | 241 | 0.24 / 75.13 | 2 | 2 |
2 | 3 | 465.20 | -1 | 15.57 | 0 | 0 | 0.00 / 75.13 | 2 | 2 |
3 | 7 | 523.72 | 38 | 15.38 | 946 | 553 | 0.79 / 75.68 | 2 | 3 |
4 | 8 | -0.04 | 165 | 15.43 | 250 | 636 | 1.43 / 76.32 | 2 | 5 |
5 | 14 | -0.04 | 30 | 15.41 | 250 | 116 | 1.55 / 76.44 | 3 | 7 |
Average= | 1.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 38 | 15.39 | 399 | 233 | 0.23 / 73.69 | 2 | 2 |
2 | 7 | 533.12 | 38 | 15.37 | 959 | 560 | 0.79 / 74.25 | 2 | 3 |
3 | 8 | 0.16 | 165 | 15.43 | 252 | 642 | 1.44 / 74.89 | 2 | 5 |
Average= | 1.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 38 | 15.38 | 402 | 235 | 0.23 / 72.29 | 2 | 2 |
2 | 7 | 497.48 | 38 | 15.38 | 908 | 531 | 0.77 / 72.82 | 2 | 3 |
3 | 8 | 0.12 | 165 | 15.43 | 250 | 636 | 1.40 / 73.45 | 2 | 6 |
Average= | 1.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 38 | 15.38 | 395 | 231 | 0.23 / 70.84 | 2 | 3 |
2 | 3 | 473.04 | -1 | 15.57 | 0 | 0 | 0.00 / 70.84 | 2 | 3 |
3 | 7 | 538.68 | 38 | 15.37 | 969 | 566 | 0.80 / 71.41 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.42 | 253 | 644 | 1.44 / 72.05 | 2 | 5 |
Average= | 1.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 38 | 15.40 | 399 | 233 | 0.23 / 69.41 | 2 | 2 |
2 | 3 | 466.36 | -1 | 15.57 | 0 | 0 | 0.00 / 69.41 | 2 | 2 |
3 | 7 | 523.20 | 38 | 15.37 | 948 | 554 | 0.79 / 69.97 | 2 | 3 |
4 | 8 | 0.24 | 165 | 15.43 | 253 | 644 | 1.43 / 70.61 | 2 | 6 |
Average= | 1.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 38 | 15.38 | 402 | 235 | 0.23 / 67.98 | 2 | 2 |
2 | 7 | 524.40 | 38 | 15.37 | 947 | 553 | 0.79 / 68.54 | 2 | 3 |
3 | 8 | 0.16 | 165 | 15.43 | 253 | 644 | 1.43 / 69.18 | 2 | 6 |
Average= | 1.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 38 | 15.39 | 406 | 237 | 0.24 / 66.54 | 2 | 2 |
2 | 3 | 473.24 | -1 | 15.58 | 0 | 0 | 0.00 / 66.54 | 2 | 2 |
3 | 7 | 533.24 | 38 | 15.37 | 960 | 561 | 0.80 / 67.10 | 2 | 3 |
4 | 8 | 0.20 | 165 | 15.43 | 255 | 649 | 1.45 / 67.75 | 2 | 8 |
Average= | 1.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 38 | 15.38 | 401 | 234 | 0.23 / 65.10 | 2 | 3 |
2 | 7 | 518.56 | 39 | 15.37 | 937 | 562 | 0.80 / 65.66 | 2 | 3 |
3 | 8 | 0.16 | 165 | 15.43 | 252 | 642 | 1.44 / 66.30 | 2 | 8 |
Average= | 2.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 38 | 15.39 | 391 | 229 | 0.23 / 63.65 | 2 | 2 |
2 | 3 | 466.96 | -1 | 15.57 | 0 | 0 | 0.00 / 63.65 | 2 | 2 |
3 | 7 | 526.56 | 38 | 15.36 | 956 | 558 | 0.79 / 64.21 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.43 | 258 | 657 | 1.44 / 64.86 | 2 | 6 |
Average= | 2.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 38 | 15.37 | 406 | 237 | 0.24 / 62.23 | 2 | 2 |
2 | 7 | 508.00 | 38 | 15.37 | 927 | 541 | 0.78 / 62.77 | 2 | 3 |
3 | 8 | 0.16 | 165 | 15.42 | 255 | 649 | 1.43 / 63.42 | 2 | 4 |
Average= | 2.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 38 | 15.37 | 397 | 232 | 0.23 / 60.77 | 2 | 2 |
2 | 3 | 455.84 | -1 | 15.56 | 0 | 0 | 0.00 / 60.77 | 2 | 2 |
3 | 7 | 537.44 | 38 | 15.36 | 968 | 565 | 0.80 / 61.34 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.42 | 258 | 656 | 1.45 / 61.99 | 2 | 7 |
Average= | 2.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.28 | 38 | 15.37 | 398 | 232 | 0.23 / 59.19 | 2 | 2 |
2 | 3 | 482.08 | -1 | 15.55 | 0 | 0 | 0.00 / 59.19 | 2 | 2 |
3 | 7 | 530.48 | 39 | 15.37 | 960 | 575 | 0.81 / 59.77 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.42 | 257 | 654 | 1.46 / 60.42 | 2 | 6 |
5 | 14 | 0.12 | 30 | 15.40 | 255 | 118 | 1.58 / 60.54 | 2 | 6 |
Average= | 2.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 21 | 15.32 | 409 | 132 | 0.13 / 57.19 | 2 | 2 |
2 | 7 | 999.88 | 38 | 15.25 | 1588 | 920 | 1.05 / 58.11 | 2 | 3 |
3 | 13 | 254.20 | 18 | 15.41 | 621 | 172 | 1.22 / 58.28 | 2 | 4 |
4 | 8 | -0.04 | 165 | 15.41 | 267 | 679 | 1.90 / 58.96 | 2 | 6 |
Average= | 2.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 23 | 15.39 | 399 | 141 | 0.14 / 53.91 | 2 | 2 |
2 | 3 | 947.88 | -2 | 15.63 | 0 | 0 | 0.00 / 53.91 | 2 | 2 |
3 | 7 | 1861.36 | 38 | 14.95 | 2628 | 1493 | 1.63 / 55.41 | 2 | 3 |
4 | 13 | 1117.92 | 18 | 15.12 | 1746 | 475 | 2.11 / 55.88 | 2 | 3 |
5 | 13 | 677.36 | 18 | 15.21 | 1192 | 326 | 2.44 / 56.21 | 2 | 4 |
6 | 13 | 238.08 | 18 | 15.32 | 602 | 166 | 2.60 / 56.37 | 2 | 4 |
7 | 8 | 0.32 | 165 | 15.34 | 270 | 683 | 3.29 / 57.06 | 2 | 6 |
Average= | 2.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 38 | 15.39 | 400 | 234 | 0.23 / 52.57 | 2 | 2 |
2 | 7 | 520.52 | 39 | 15.38 | 944 | 566 | 0.80 / 53.14 | 2 | 3 |
3 | 8 | 0.04 | 165 | 15.43 | 249 | 634 | 1.43 / 53.77 | 2 | 4 |
Average= | 2.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 38 | 15.40 | 398 | 233 | 0.23 / 51.11 | 2 | 2 |
2 | 3 | 478.72 | -1 | 15.58 | 0 | 0 | 0.00 / 51.11 | 2 | 2 |
3 | 7 | 539.60 | 38 | 15.38 | 973 | 569 | 0.80 / 51.68 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.43 | 257 | 654 | 1.46 / 52.34 | 2 | 6 |
Average= | 2.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 37 | 15.38 | 400 | 228 | 0.23 / 49.68 | 2 | 2 |
2 | 7 | 509.40 | 39 | 15.39 | 928 | 557 | 0.78 / 50.23 | 2 | 3 |
3 | 8 | 0.20 | 165 | 15.44 | 254 | 647 | 1.43 / 50.88 | 2 | 6 |
Average= | 2.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 38 | 15.40 | 401 | 235 | 0.23 / 48.14 | 2 | 2 |
2 | 3 | 450.28 | -1 | 15.57 | 0 | 0 | 0.00 / 48.14 | 2 | 2 |
3 | 7 | 507.00 | 38 | 15.40 | 930 | 544 | 0.78 / 48.69 | 2 | 3 |
4 | 8 | 0.36 | 165 | 15.44 | 254 | 647 | 1.43 / 49.33 | 2 | 10 |
5 | 14 | 0.36 | 30 | 15.42 | 254 | 118 | 1.54 / 49.45 | 3 | 8 |
Average= | 2.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 38 | 15.40 | 401 | 235 | 0.23 / 46.60 | 2 | 2 |
2 | 7 | 512.20 | 38 | 15.39 | 935 | 547 | 0.78 / 47.14 | 2 | 3 |
3 | 8 | 0.08 | 165 | 15.44 | 254 | 647 | 1.43 / 47.79 | 2 | 6 |
4 | 14 | 0.08 | 30 | 15.42 | 253 | 117 | 1.55 / 47.91 | 2 | 4 |
Average= | 2.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 38 | 15.39 | 396 | 232 | 0.23 / 45.13 | 2 | 2 |
2 | 3 | 463.88 | -1 | 15.57 | 0 | 0 | 0.00 / 45.13 | 2 | 2 |
3 | 7 | 535.08 | 39 | 15.37 | 967 | 580 | 0.81 / 45.71 | 2 | 3 |
4 | 8 | 0.00 | 165 | 15.43 | 257 | 654 | 1.47 / 46.36 | 2 | 4 |
Average= | 2.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.56 | 38 | 15.39 | 400 | 234 | 0.23 / 43.56 | 2 | 2 |
2 | 3 | 471.56 | -1 | 15.57 | 0 | 0 | 0.00 / 43.56 | 2 | 2 |
3 | 7 | 538.20 | 38 | 15.38 | 972 | 568 | 0.80 / 44.13 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.43 | 256 | 652 | 1.45 / 44.78 | 2 | 9 |
5 | 14 | 0.12 | 30 | 15.41 | 255 | 118 | 1.57 / 44.90 | 2 | 6 |
Average= | 2.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 38 | 15.38 | 395 | 231 | 0.23 / 42.11 | 2 | 2 |
2 | 3 | 452.24 | -1 | 15.58 | 0 | 0 | 0.00 / 42.11 | 2 | 2 |
3 | 7 | 523.08 | 39 | 15.38 | 948 | 569 | 0.80 / 42.68 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.43 | 254 | 647 | 1.45 / 43.32 | 2 | 6 |
Average= | 2.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.00 | 38 | 15.40 | 397 | 232 | 0.23 / 40.51 | 2 | 2 |
2 | 3 | 471.04 | -1 | 15.58 | 0 | 0 | 0.00 / 40.51 | 2 | 2 |
3 | 7 | 547.28 | 39 | 15.38 | 984 | 590 | 0.82 / 41.10 | 2 | 3 |
4 | 8 | -0.08 | 165 | 15.44 | 257 | 655 | 1.48 / 41.76 | 2 | 7 |
5 | 14 | -0.08 | 30 | 15.41 | 256 | 118 | 1.60 / 41.88 | 2 | 6 |
Average= | 2.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 38 | 15.40 | 402 | 235 | 0.24 / 39.08 | 2 | 2 |
2 | 7 | 515.00 | 38 | 15.39 | 940 | 550 | 0.78 / 39.63 | 2 | 3 |
3 | 8 | 0.12 | 165 | 15.44 | 255 | 650 | 1.43 / 40.28 | 2 | 6 |
Average= | 2.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 38 | 15.38 | 395 | 231 | 0.23 / 37.62 | 2 | 2 |
2 | 3 | 449.28 | -2 | 15.58 | 0 | 0 | 0.00 / 37.62 | 2 | 2 |
3 | 7 | 547.56 | 38 | 15.38 | 985 | 576 | 0.81 / 38.20 | 2 | 3 |
4 | 8 | 0.08 | 165 | 15.44 | 256 | 652 | 1.46 / 38.85 | 2 | 5 |
Average= | 2.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 38 | 15.38 | 399 | 233 | 0.23 / 36.07 | 2 | 2 |
2 | 3 | 479.28 | -1 | 15.57 | 0 | 0 | 0.00 / 36.07 | 2 | 2 |
3 | 7 | 531.76 | 38 | 15.39 | 960 | 561 | 0.79 / 36.63 | 2 | 3 |
4 | 8 | 0.00 | 165 | 15.44 | 253 | 645 | 1.44 / 37.27 | 2 | 7 |
5 | 14 | 0.00 | 30 | 15.42 | 253 | 117 | 1.56 / 37.39 | 2 | 7 |
Average= | 2.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 38 | 15.38 | 410 | 240 | 0.24 / 34.61 | 2 | 2 |
2 | 7 | 524.72 | 38 | 15.38 | 958 | 560 | 0.80 / 35.17 | 2 | 3 |
3 | 8 | 0.08 | 165 | 15.44 | 260 | 662 | 1.46 / 35.83 | 2 | 5 |
Average= | 2.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 38 | 15.38 | 397 | 232 | 0.23 / 33.13 | 2 | 2 |
2 | 3 | 481.84 | -1 | 15.57 | 0 | 0 | 0.00 / 33.13 | 2 | 2 |
3 | 7 | 532.20 | 39 | 15.38 | 969 | 581 | 0.81 / 33.71 | 2 | 3 |
4 | 8 | 0.16 | 165 | 15.43 | 260 | 662 | 1.48 / 34.37 | 2 | 5 |
Average= | 2.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 35 | 15.37 | 405 | 218 | 0.22 / 31.64 | 2 | 2 |
2 | 10 | 531.80 | 2 | 15.40 | 984 | 30 | 0.25 / 31.67 | 2 | 2 |
3 | 3 | 533.76 | 1 | 15.42 | 986 | 15 | 0.26 / 31.69 | 2 | 3 |
4 | 7 | 516.28 | 38 | 15.37 | 945 | 552 | 0.82 / 32.24 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.44 | 258 | 657 | 1.47 / 32.90 | 2 | 7 |
Average= | 2.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 22 | 15.40 | 422 | 143 | 0.14 / 29.63 | 2 | 2 |
2 | 3 | 968.64 | -1 | 15.65 | 0 | 0 | 0.00 / 29.63 | 2 | 2 |
3 | 7 | 1011.60 | 38 | 15.25 | 1604 | 930 | 1.07 / 30.56 | 2 | 3 |
4 | 13 | 239.84 | 18 | 15.42 | 605 | 168 | 1.24 / 30.73 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.42 | 272 | 692 | 1.93 / 31.42 | 2 | 8 |
Average= | 2.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 23 | 15.38 | 426 | 151 | 0.15 / 27.68 | 2 | 2 |
2 | 3 | 948.72 | -2 | 15.66 | 0 | 0 | 0.00 / 27.68 | 2 | 2 |
3 | 3 | 1017.72 | 1 | 15.35 | 1701 | 26 | 0.18 / 27.71 | 2 | 3 |
4 | 7 | 996.16 | 38 | 15.26 | 1585 | 919 | 1.10 / 28.63 | 2 | 3 |
5 | 13 | 246.00 | 18 | 15.43 | 611 | 170 | 1.27 / 28.80 | 2 | 4 |
6 | 8 | 0.08 | 165 | 15.43 | 272 | 692 | 1.96 / 29.49 | 2 | 5 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 24 | 15.32 | 427 | 157 | 0.16 / 25.61 | 2 | 2 |
2 | 3 | 949.96 | -2 | 15.65 | 0 | 0 | 0.00 / 25.61 | 2 | 2 |
3 | 7 | 1011.84 | 38 | 15.26 | 1608 | 932 | 1.09 / 26.54 | 2 | 3 |
4 | 13 | 257.24 | 18 | 15.42 | 627 | 174 | 1.26 / 26.71 | 2 | 4 |
5 | 8 | 0.24 | 165 | 15.43 | 273 | 695 | 1.96 / 27.41 | 2 | 7 |
6 | 14 | 0.24 | 30 | 15.41 | 271 | 125 | 2.08 / 27.53 | 2 | 8 |
Average= | 3.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 21 | 15.32 | 415 | 134 | 0.13 / 22.24 | 2 | 2 |
2 | 10 | 1005.36 | 2 | 15.27 | 1649 | 50 | 0.18 / 22.29 | 2 | 2 |
3 | 7 | 1874.24 | 38 | 14.96 | 2658 | 1511 | 1.69 / 23.81 | 2 | 3 |
4 | 13 | 1123.12 | 18 | 15.13 | 1762 | 480 | 2.17 / 24.28 | 2 | 3 |
5 | 13 | 702.40 | 18 | 15.21 | 1234 | 338 | 2.51 / 24.62 | 2 | 4 |
6 | 13 | 140.76 | 18 | 15.36 | 469 | 130 | 2.64 / 24.75 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.34 | 275 | 696 | 3.34 / 25.45 | 2 | 8 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 21 | 15.29 | 415 | 133 | 0.13 / 18.85 | 2 | 2 |
2 | 7 | 1869.12 | 38 | 14.95 | 2644 | 1502 | 1.64 / 20.35 | 2 | 3 |
3 | 13 | 1240.16 | 18 | 15.09 | 1895 | 515 | 2.15 / 20.86 | 2 | 3 |
4 | 13 | 660.36 | 18 | 15.22 | 1173 | 321 | 2.47 / 21.18 | 2 | 3 |
5 | 13 | 128.08 | 18 | 15.36 | 443 | 122 | 2.59 / 21.31 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.35 | 269 | 681 | 3.28 / 21.99 | 2 | 9 |
7 | 14 | 0.00 | 30 | 15.33 | 268 | 123 | 3.40 / 22.11 | 2 | 8 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 29 | 15.31 | 408 | 181 | 0.18 / 14.51 | 2 | 2 |
2 | 3 | 770.72 | -4 | 15.66 | 0 | 0 | 0.00 / 14.51 | 2 | 2 |
3 | 3 | 882.16 | -2 | 15.67 | 0 | 0 | 0.00 / 14.51 | 2 | 2 |
4 | 7 | 1864.88 | 75 | 14.85 | 2624 | 2922 | 3.10 / 17.43 | 2 | 3 |
5 | 13 | 328.56 | 18 | 15.31 | 724 | 200 | 3.30 / 17.63 | 2 | 4 |
6 | 13 | 34.24 | 18 | 15.37 | 323 | 89 | 3.39 / 17.72 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.35 | 271 | 686 | 4.08 / 18.41 | 2 | 8 |
8 | 14 | 0.16 | 75 | 15.32 | 265 | 304 | 4.38 / 18.71 | 3 | 11 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 21 | 15.32 | 406 | 131 | 0.13 / 11.09 | 2 | 2 |
2 | 7 | 1515.04 | 74 | 14.98 | 2199 | 2438 | 2.57 / 13.53 | 2 | 3 |
3 | 13 | 126.12 | 18 | 15.37 | 441 | 122 | 2.69 / 13.65 | 2 | 3 |
4 | 8 | 0.12 | 165 | 15.35 | 267 | 676 | 3.37 / 14.33 | 2 | 6 |
Average= | 2.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 20 | 15.32 | 408 | 125 | 0.13 / 7.69 | 2 | 2 |
2 | 3 | 1044.24 | 1 | 15.29 | 1733 | 26 | 0.15 / 7.72 | 2 | 3 |
3 | 7 | 1521.68 | 74 | 14.98 | 2208 | 2448 | 2.60 / 10.16 | 2 | 3 |
4 | 13 | 128.96 | 18 | 15.36 | 446 | 123 | 2.72 / 10.29 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.35 | 266 | 674 | 3.40 / 10.96 | 2 | 6 |
Average= | 2.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 32 | 15.33 | 409 | 201 | 0.20 / 4.28 | 2 | 2 |
2 | 3 | 687.52 | -6 | 15.65 | 0 | 0 | 0.00 / 4.28 | 2 | 2 |
3 | 3 | 842.48 | -3 | 15.69 | 0 | 0 | 0.00 / 4.28 | 2 | 2 |
4 | 7 | 1518.52 | 74 | 14.98 | 2203 | 2442 | 2.64 / 6.72 | 2 | 3 |
5 | 13 | 221.00 | 18 | 15.33 | 575 | 159 | 2.80 / 6.88 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.35 | 270 | 684 | 3.49 / 7.57 | 2 | 8 |
Average= | 2.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.60 | 27 | 15.50 | 372 | 156 | 0.16 / 1.62 | 2 | 3 |
2 | 3 | 845.64 | -3 | 15.67 | 0 | 0 | 0.00 / 1.62 | 2 | 3 |
3 | 3 | 972.36 | -1 | 15.68 | 0 | 0 | 0.00 / 1.62 | 2 | 3 |
4 | 7 | 1003.88 | 74 | 15.14 | 1575 | 1765 | 1.92 / 3.38 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.37 | 276 | 700 | 2.62 / 4.08 | 2 | 11 |
Average= | 2.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 26 | 15.63 | 377 | 153 | 0.15 / 0.15 | 2 | 3 |
2 | 7 | 120.32 | 74 | 15.60 | 398 | 459 | 0.61 / 0.61 | 2 | 3 |
3 | 8 | 0.08 | 240 | 15.56 | 227 | 848 | 1.46 / 1.46 | 2 | 7 |
Average= | 1.46 (KJ/cycle) |