SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 32 | 14.73 | 470 | 222 | 0.22 / 240.14 | 3 | 3 |
2 | 7 | 2011.80 | 50 | 14.28 | 2920 | 2085 | 2.31 / 242.22 | 3 | 3 |
3 | 13 | 1332.00 | 25 | 14.45 | 2096 | 757 | 3.06 / 242.98 | 3 | 4 |
4 | 13 | 524.76 | 25 | 14.68 | 1061 | 389 | 3.45 / 243.37 | 3 | 4 |
5 | 8 | 0.12 | 165 | 14.80 | 328 | 801 | 4.25 / 244.17 | 3 | 7 |
6 | 14 | 0.12 | 30 | 14.77 | 333 | 148 | 4.40 / 244.32 | 3 | 10 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 32 | 14.74 | 480 | 226 | 0.23 / 235.61 | 3 | 3 |
2 | 7 | 2010.52 | 50 | 14.28 | 2911 | 2078 | 2.30 / 237.69 | 3 | 3 |
3 | 13 | 1334.60 | 25 | 14.45 | 2090 | 755 | 3.06 / 238.45 | 3 | 4 |
4 | 13 | 520.56 | 25 | 14.69 | 1029 | 378 | 3.44 / 238.82 | 3 | 4 |
5 | 13 | 41.96 | 25 | 14.82 | 399 | 148 | 3.59 / 238.97 | 3 | 5 |
6 | 8 | -0.28 | 165 | 14.79 | 328 | 800 | 4.39 / 239.77 | 3 | 12 |
7 | 14 | -0.28 | 30 | 14.77 | 328 | 145 | 4.53 / 239.92 | 4 | 9 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 32 | 14.74 | 491 | 232 | 0.23 / 231.20 | 3 | 3 |
2 | 7 | 2001.24 | 50 | 14.28 | 2921 | 2086 | 2.32 / 233.29 | 3 | 3 |
3 | 13 | 1498.28 | 25 | 14.39 | 2327 | 837 | 3.15 / 234.12 | 3 | 4 |
4 | 13 | 605.32 | 25 | 14.65 | 1178 | 431 | 3.59 / 234.55 | 3 | 5 |
5 | 8 | 0.08 | 165 | 14.79 | 341 | 832 | 4.42 / 235.39 | 3 | 9 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 32 | 14.75 | 483 | 228 | 0.23 / 226.86 | 3 | 3 |
2 | 7 | 2013.04 | 50 | 14.28 | 2914 | 2081 | 2.31 / 228.94 | 3 | 4 |
3 | 13 | 1450.36 | 25 | 14.41 | 2235 | 805 | 3.11 / 229.74 | 3 | 6 |
4 | 13 | 612.96 | 25 | 14.65 | 1150 | 421 | 3.53 / 230.16 | 3 | 4 |
5 | 8 | 0.12 | 165 | 14.80 | 329 | 803 | 4.34 / 230.97 | 3 | 9 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 32 | 14.75 | 489 | 231 | 0.23 / 222.56 | 3 | 3 |
2 | 7 | 2011.48 | 50 | 14.28 | 2931 | 2093 | 2.32 / 224.65 | 3 | 3 |
3 | 13 | 1378.36 | 25 | 14.43 | 2181 | 787 | 3.11 / 225.44 | 3 | 6 |
4 | 13 | 505.80 | 25 | 14.69 | 1040 | 382 | 3.49 / 225.82 | 3 | 5 |
5 | 8 | 0.00 | 165 | 14.80 | 332 | 811 | 4.30 / 226.63 | 3 | 7 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 32 | 14.75 | 481 | 227 | 0.23 / 218.21 | 3 | 3 |
2 | 7 | 2011.48 | 50 | 14.28 | 2937 | 2097 | 2.32 / 220.31 | 3 | 3 |
3 | 13 | 1385.52 | 25 | 14.43 | 2200 | 794 | 3.12 / 221.10 | 3 | 4 |
4 | 13 | 556.24 | 25 | 14.67 | 1118 | 410 | 3.53 / 221.51 | 3 | 5 |
5 | 8 | 0.20 | 165 | 14.80 | 334 | 816 | 4.34 / 222.33 | 3 | 11 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 32 | 14.74 | 519 | 245 | 0.24 / 213.72 | 3 | 3 |
2 | 7 | 2012.08 | 50 | 14.29 | 2918 | 2085 | 2.33 / 215.80 | 3 | 3 |
3 | 13 | 1510.52 | 25 | 14.40 | 2308 | 831 | 3.16 / 216.63 | 3 | 6 |
4 | 13 | 547.76 | 25 | 14.69 | 1066 | 391 | 3.55 / 217.02 | 3 | 4 |
5 | 8 | -0.16 | 165 | 14.81 | 332 | 811 | 4.36 / 217.83 | 3 | 11 |
6 | 14 | -0.16 | 30 | 14.78 | 335 | 149 | 4.51 / 217.98 | 3 | 11 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 32 | 14.75 | 479 | 226 | 0.23 / 209.33 | 3 | 3 |
2 | 7 | 2012.32 | 50 | 14.29 | 2918 | 2085 | 2.31 / 211.41 | 3 | 3 |
3 | 13 | 1406.52 | 25 | 14.44 | 2196 | 793 | 3.10 / 212.20 | 3 | 5 |
4 | 13 | 638.64 | 25 | 14.65 | 1223 | 448 | 3.55 / 212.65 | 3 | 6 |
5 | 8 | 0.00 | 165 | 14.80 | 336 | 821 | 4.37 / 213.47 | 3 | 10 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 32 | 14.74 | 488 | 230 | 0.23 / 204.80 | 3 | 3 |
2 | 7 | 2014.44 | 50 | 14.28 | 2942 | 2101 | 2.33 / 206.90 | 3 | 4 |
3 | 13 | 1402.56 | 25 | 14.43 | 2220 | 801 | 3.13 / 207.71 | 3 | 6 |
4 | 13 | 582.64 | 25 | 14.67 | 1143 | 419 | 3.55 / 208.12 | 3 | 4 |
5 | 8 | -0.08 | 165 | 14.81 | 337 | 824 | 4.37 / 208.95 | 3 | 8 |
6 | 14 | -0.08 | 30 | 14.78 | 341 | 151 | 4.53 / 209.10 | 3 | 9 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 32 | 14.75 | 478 | 226 | 0.23 / 200.32 | 3 | 3 |
2 | 7 | 2008.56 | 50 | 14.29 | 2926 | 2091 | 2.32 / 202.41 | 3 | 3 |
3 | 13 | 1285.84 | 25 | 14.47 | 2056 | 744 | 3.06 / 203.15 | 3 | 3 |
4 | 13 | 654.08 | 25 | 14.65 | 1240 | 454 | 3.51 / 203.61 | 3 | 4 |
5 | 8 | 0.20 | 165 | 14.81 | 336 | 821 | 4.34 / 204.43 | 3 | 11 |
6 | 14 | 0.20 | 30 | 14.78 | 332 | 147 | 4.48 / 204.57 | 3 | 9 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 31 | 14.75 | 486 | 222 | 0.22 / 195.81 | 3 | 3 |
2 | 7 | 2013.92 | 50 | 14.29 | 2921 | 2087 | 2.31 / 197.90 | 3 | 3 |
3 | 13 | 1448.44 | 25 | 14.42 | 2272 | 819 | 3.13 / 198.71 | 3 | 3 |
4 | 13 | 552.64 | 25 | 14.68 | 1112 | 408 | 3.54 / 199.12 | 3 | 4 |
5 | 8 | 0.08 | 165 | 14.81 | 334 | 816 | 4.35 / 199.94 | 3 | 8 |
6 | 14 | 0.08 | 30 | 14.79 | 344 | 153 | 4.51 / 200.09 | 3 | 11 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 31 | 14.76 | 480 | 220 | 0.22 / 191.48 | 3 | 3 |
2 | 7 | 2010.96 | 50 | 14.29 | 2927 | 2091 | 2.31 / 193.57 | 3 | 3 |
3 | 13 | 1395.28 | 25 | 14.44 | 2186 | 789 | 3.10 / 194.36 | 3 | 3 |
4 | 13 | 567.52 | 25 | 14.68 | 1124 | 413 | 3.51 / 194.77 | 3 | 4 |
5 | 8 | 0.08 | 165 | 14.82 | 334 | 817 | 4.33 / 195.59 | 3 | 9 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 31 | 14.76 | 484 | 221 | 0.22 / 187.12 | 3 | 3 |
2 | 3 | 1016.64 | 1 | 14.72 | 1750 | 26 | 0.25 / 187.14 | 3 | 3 |
3 | 7 | 2011.56 | 50 | 14.29 | 2931 | 2094 | 2.34 / 189.24 | 3 | 3 |
4 | 13 | 1389.80 | 25 | 14.45 | 2189 | 791 | 3.13 / 190.03 | 3 | 3 |
5 | 13 | 570.28 | 25 | 14.68 | 1128 | 414 | 3.55 / 190.44 | 3 | 4 |
6 | 8 | -0.12 | 165 | 14.82 | 333 | 814 | 4.36 / 191.26 | 3 | 11 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 31 | 14.76 | 481 | 220 | 0.22 / 182.80 | 3 | 3 |
2 | 7 | 2002.60 | 50 | 14.30 | 2913 | 2083 | 2.30 / 184.89 | 3 | 3 |
3 | 13 | 1400.52 | 25 | 14.45 | 2177 | 786 | 3.09 / 185.67 | 3 | 3 |
4 | 13 | 556.56 | 25 | 14.69 | 1104 | 405 | 3.49 / 186.08 | 3 | 4 |
5 | 8 | -0.12 | 165 | 14.82 | 334 | 817 | 4.31 / 186.90 | 3 | 5 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 31 | 14.76 | 507 | 232 | 0.23 / 178.50 | 3 | 3 |
2 | 7 | 2003.44 | 50 | 14.31 | 2897 | 2073 | 2.30 / 180.57 | 3 | 3 |
3 | 13 | 1387.56 | 25 | 14.45 | 2167 | 783 | 3.09 / 181.35 | 3 | 3 |
4 | 13 | 604.92 | 25 | 14.68 | 1140 | 418 | 3.51 / 181.77 | 3 | 4 |
5 | 8 | -0.08 | 165 | 14.82 | 332 | 812 | 4.32 / 182.58 | 3 | 10 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 31 | 14.76 | 486 | 222 | 0.22 / 174.18 | 3 | 3 |
2 | 7 | 2010.44 | 50 | 14.30 | 2920 | 2088 | 2.31 / 176.26 | 3 | 3 |
3 | 13 | 1389.24 | 25 | 14.46 | 2153 | 778 | 3.09 / 177.04 | 3 | 3 |
4 | 13 | 629.76 | 25 | 14.67 | 1175 | 431 | 3.52 / 177.47 | 3 | 4 |
5 | 8 | 0.20 | 165 | 14.83 | 324 | 793 | 4.31 / 178.27 | 3 | 8 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 31 | 14.77 | 498 | 228 | 0.23 / 169.67 | 3 | 3 |
2 | 7 | 2001.68 | 50 | 14.31 | 2899 | 2074 | 2.30 / 171.74 | 3 | 3 |
3 | 13 | 1377.80 | 25 | 14.46 | 2176 | 787 | 3.09 / 172.53 | 3 | 3 |
4 | 13 | 673.28 | 25 | 14.65 | 1272 | 466 | 3.55 / 172.99 | 3 | 4 |
5 | 8 | -0.04 | 165 | 14.82 | 332 | 812 | 4.37 / 173.81 | 3 | 10 |
6 | 14 | -0.04 | 30 | 14.80 | 334 | 148 | 4.51 / 173.95 | 3 | 12 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 31 | 14.76 | 489 | 224 | 0.22 / 165.42 | 3 | 3 |
2 | 7 | 2012.04 | 50 | 14.30 | 2927 | 2093 | 2.32 / 167.51 | 3 | 3 |
3 | 13 | 1269.16 | 25 | 14.50 | 2007 | 728 | 3.04 / 168.24 | 3 | 3 |
4 | 13 | 467.04 | 25 | 14.73 | 994 | 366 | 3.41 / 168.61 | 3 | 4 |
5 | 8 | 0.00 | 165 | 14.83 | 340 | 832 | 4.24 / 169.44 | 3 | 7 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 31 | 14.77 | 498 | 228 | 0.23 / 161.05 | 3 | 3 |
2 | 7 | 2012.12 | 50 | 14.31 | 2914 | 2085 | 2.31 / 163.13 | 3 | 3 |
3 | 13 | 1394.68 | 25 | 14.46 | 2193 | 793 | 3.11 / 163.93 | 3 | 3 |
4 | 13 | 626.44 | 25 | 14.67 | 1205 | 442 | 3.55 / 164.37 | 3 | 4 |
5 | 8 | 0.04 | 165 | 14.82 | 339 | 829 | 4.38 / 165.20 | 3 | 7 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 30 | 14.76 | 495 | 219 | 0.22 / 156.62 | 3 | 3 |
2 | 10 | 1003.80 | 2 | 14.67 | 1726 | 51 | 0.27 / 156.67 | 3 | 3 |
3 | 3 | 975.16 | -1 | 14.97 | 25 | 0 | 0.05 / 156.67 | 3 | 3 |
4 | 3 | 1019.56 | 1 | 14.74 | 1768 | 26 | 0.30 / 156.69 | 3 | 3 |
5 | 7 | 2003.00 | 50 | 14.31 | 2917 | 2087 | 2.38 / 158.78 | 3 | 3 |
6 | 13 | 1396.20 | 25 | 14.46 | 2202 | 796 | 3.18 / 159.58 | 3 | 3 |
7 | 13 | 554.04 | 25 | 14.70 | 1115 | 410 | 3.59 / 159.99 | 3 | 4 |
8 | 8 | 0.28 | 165 | 14.83 | 341 | 834 | 4.42 / 160.82 | 3 | 11 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 30 | 14.77 | 487 | 216 | 0.22 / 152.10 | 3 | 3 |
2 | 7 | 2006.60 | 50 | 14.31 | 2910 | 2082 | 2.30 / 154.18 | 3 | 3 |
3 | 13 | 1449.64 | 25 | 14.44 | 2260 | 816 | 3.11 / 154.99 | 3 | 3 |
4 | 13 | 556.60 | 25 | 14.70 | 1115 | 410 | 3.52 / 155.40 | 3 | 4 |
5 | 8 | -0.12 | 165 | 14.83 | 345 | 844 | 4.37 / 156.25 | 3 | 12 |
6 | 14 | -0.12 | 30 | 14.80 | 337 | 150 | 4.52 / 156.40 | 3 | 10 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 30 | 14.77 | 493 | 218 | 0.22 / 147.79 | 3 | 3 |
2 | 7 | 2012.56 | 50 | 14.31 | 2901 | 2076 | 2.29 / 149.86 | 3 | 3 |
3 | 13 | 1353.48 | 25 | 14.49 | 2114 | 766 | 3.06 / 150.63 | 3 | 3 |
4 | 13 | 602.16 | 25 | 14.69 | 1168 | 429 | 3.49 / 151.06 | 3 | 4 |
5 | 8 | -0.04 | 165 | 14.83 | 336 | 822 | 4.31 / 151.88 | 3 | 7 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 30 | 14.77 | 491 | 218 | 0.22 / 143.53 | 3 | 3 |
2 | 7 | 2001.56 | 50 | 14.32 | 2900 | 2076 | 2.29 / 145.60 | 3 | 3 |
3 | 13 | 1382.52 | 25 | 14.48 | 2150 | 778 | 3.07 / 146.38 | 3 | 3 |
4 | 13 | 444.24 | 25 | 14.75 | 958 | 353 | 3.43 / 146.73 | 3 | 4 |
5 | 8 | -0.04 | 165 | 14.84 | 341 | 835 | 4.26 / 147.57 | 3 | 7 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 30 | 14.76 | 495 | 219 | 0.22 / 139.20 | 3 | 3 |
2 | 7 | 2001.32 | 50 | 14.32 | 2895 | 2073 | 2.29 / 141.27 | 3 | 3 |
3 | 13 | 1338.44 | 25 | 14.49 | 2119 | 768 | 3.06 / 142.04 | 3 | 3 |
4 | 13 | 522.72 | 25 | 14.73 | 1054 | 388 | 3.45 / 142.43 | 3 | 4 |
5 | 8 | 0.28 | 165 | 14.83 | 361 | 883 | 4.33 / 143.31 | 3 | 10 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 31 | 14.78 | 510 | 234 | 0.23 / 134.67 | 3 | 3 |
2 | 3 | 964.88 | -1 | 14.99 | 25 | 0 | 0.00 / 134.67 | 3 | 3 |
3 | 3 | 1016.08 | 1 | 14.75 | 1760 | 26 | 0.26 / 134.70 | 3 | 3 |
4 | 7 | 2001.80 | 50 | 14.33 | 2888 | 2069 | 2.33 / 136.76 | 3 | 3 |
5 | 13 | 1447.56 | 25 | 14.46 | 2241 | 810 | 3.14 / 137.57 | 3 | 3 |
6 | 13 | 618.04 | 25 | 14.69 | 1189 | 437 | 3.58 / 138.01 | 3 | 4 |
7 | 8 | -0.52 | 165 | 14.84 | 334 | 818 | 4.39 / 138.83 | 3 | 6 |
8 | 14 | -0.52 | 30 | 14.81 | 335 | 149 | 4.54 / 138.98 | 3 | 13 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 31 | 14.78 | 502 | 230 | 0.23 / 130.29 | 3 | 3 |
2 | 7 | 2011.60 | 50 | 14.33 | 2893 | 2073 | 2.30 / 132.36 | 3 | 3 |
3 | 13 | 1463.72 | 25 | 14.46 | 2264 | 818 | 3.12 / 133.18 | 3 | 3 |
4 | 13 | 617.96 | 25 | 14.69 | 1187 | 436 | 3.56 / 133.62 | 3 | 4 |
5 | 8 | 0.20 | 165 | 14.84 | 334 | 818 | 4.38 / 134.44 | 3 | 8 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 31 | 14.78 | 479 | 219 | 0.22 / 125.92 | 3 | 3 |
2 | 7 | 2012.92 | 50 | 14.32 | 2924 | 2094 | 2.31 / 128.02 | 3 | 3 |
3 | 13 | 1387.68 | 25 | 14.47 | 2196 | 794 | 3.11 / 128.81 | 3 | 3 |
4 | 13 | 573.08 | 25 | 14.71 | 1138 | 418 | 3.53 / 129.23 | 3 | 4 |
5 | 8 | 0.00 | 165 | 14.84 | 339 | 830 | 4.36 / 130.06 | 3 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 31 | 14.77 | 504 | 231 | 0.23 / 121.49 | 3 | 3 |
2 | 7 | 2010.40 | 50 | 14.32 | 2924 | 2094 | 2.32 / 123.58 | 3 | 3 |
3 | 13 | 1324.84 | 25 | 14.50 | 2098 | 761 | 3.08 / 124.34 | 3 | 3 |
4 | 13 | 514.36 | 25 | 14.74 | 1047 | 386 | 3.47 / 124.73 | 3 | 4 |
5 | 8 | 0.44 | 165 | 14.85 | 337 | 826 | 4.30 / 125.55 | 3 | 9 |
6 | 14 | 0.44 | 30 | 14.82 | 338 | 150 | 4.45 / 125.70 | 3 | 9 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 31 | 14.78 | 497 | 228 | 0.23 / 116.98 | 3 | 3 |
2 | 7 | 2011.92 | 50 | 14.33 | 2914 | 2088 | 2.32 / 119.07 | 3 | 3 |
3 | 13 | 1336.96 | 25 | 14.49 | 2121 | 768 | 3.08 / 119.84 | 3 | 3 |
4 | 13 | 576.04 | 25 | 14.71 | 1145 | 421 | 3.51 / 120.26 | 3 | 4 |
5 | 8 | -0.12 | 165 | 14.84 | 346 | 847 | 4.35 / 121.11 | 3 | 8 |
6 | 14 | -0.12 | 30 | 14.82 | 339 | 151 | 4.50 / 121.26 | 3 | 10 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 31 | 14.79 | 493 | 226 | 0.23 / 112.64 | 3 | 3 |
2 | 7 | 2001.64 | 50 | 14.34 | 2887 | 2070 | 2.30 / 114.71 | 3 | 3 |
3 | 13 | 1448.40 | 25 | 14.47 | 2252 | 815 | 3.11 / 115.52 | 3 | 3 |
4 | 13 | 547.32 | 25 | 14.73 | 1101 | 405 | 3.52 / 115.93 | 3 | 4 |
5 | 8 | -0.04 | 165 | 14.85 | 338 | 828 | 4.34 / 116.75 | 3 | 8 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 31 | 14.79 | 506 | 232 | 0.23 / 108.27 | 3 | 3 |
2 | 7 | 2002.00 | 50 | 14.33 | 2920 | 2092 | 2.32 / 110.36 | 3 | 3 |
3 | 13 | 1389.92 | 25 | 14.48 | 2199 | 796 | 3.12 / 111.15 | 3 | 3 |
4 | 13 | 504.52 | 25 | 14.74 | 1037 | 382 | 3.50 / 111.54 | 3 | 4 |
5 | 8 | 0.00 | 165 | 14.85 | 357 | 875 | 4.38 / 112.41 | 3 | 10 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 31 | 14.79 | 490 | 225 | 0.22 / 103.93 | 3 | 3 |
2 | 7 | 2005.48 | 50 | 14.34 | 2911 | 2087 | 2.31 / 106.01 | 3 | 3 |
3 | 13 | 1377.92 | 25 | 14.49 | 2167 | 785 | 3.10 / 106.80 | 3 | 3 |
4 | 13 | 495.76 | 25 | 14.75 | 1027 | 379 | 3.48 / 107.18 | 3 | 4 |
5 | 8 | -0.12 | 165 | 14.85 | 349 | 855 | 4.33 / 108.03 | 3 | 12 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 31 | 14.78 | 529 | 242 | 0.24 / 99.57 | 3 | 3 |
2 | 7 | 2001.92 | 50 | 14.34 | 2893 | 2074 | 2.32 / 101.64 | 3 | 3 |
3 | 13 | 1441.84 | 25 | 14.47 | 2247 | 813 | 3.13 / 102.45 | 3 | 3 |
4 | 13 | 596.80 | 25 | 14.72 | 1159 | 427 | 3.56 / 102.88 | 3 | 4 |
5 | 8 | -0.08 | 165 | 14.85 | 336 | 823 | 4.38 / 103.70 | 3 | 9 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 31 | 14.80 | 487 | 223 | 0.22 / 95.23 | 3 | 3 |
2 | 7 | 2011.40 | 50 | 14.34 | 2908 | 2085 | 2.31 / 97.32 | 3 | 3 |
3 | 13 | 1380.24 | 25 | 14.50 | 2153 | 780 | 3.09 / 98.10 | 3 | 3 |
4 | 13 | 545.44 | 25 | 14.74 | 1095 | 404 | 3.49 / 98.50 | 3 | 3 |
5 | 8 | 0.44 | 165 | 14.86 | 335 | 821 | 4.31 / 99.32 | 3 | 6 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 31 | 14.79 | 482 | 221 | 0.22 / 90.90 | 3 | 3 |
2 | 7 | 2008.88 | 50 | 14.34 | 2913 | 2089 | 2.31 / 92.99 | 3 | 3 |
3 | 13 | 1341.64 | 25 | 14.51 | 2139 | 776 | 3.09 / 93.76 | 3 | 3 |
4 | 13 | 589.00 | 25 | 14.72 | 1153 | 424 | 3.51 / 94.19 | 3 | 4 |
5 | 8 | 0.04 | 165 | 14.86 | 335 | 821 | 4.33 / 95.01 | 3 | 9 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 31 | 14.80 | 479 | 220 | 0.22 / 86.30 | 3 | 3 |
2 | 7 | 2010.20 | 50 | 14.33 | 2950 | 2114 | 2.33 / 88.41 | 3 | 3 |
3 | 13 | 1442.56 | 25 | 14.47 | 2273 | 822 | 3.16 / 89.24 | 3 | 3 |
4 | 13 | 604.36 | 25 | 14.71 | 1184 | 435 | 3.59 / 89.67 | 3 | 4 |
5 | 8 | -0.16 | 165 | 14.85 | 351 | 860 | 4.45 / 90.53 | 3 | 13 |
6 | 14 | -0.16 | 30 | 14.83 | 329 | 146 | 4.60 / 90.68 | 3 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 31 | 14.81 | 480 | 220 | 0.22 / 81.84 | 3 | 3 |
2 | 7 | 2008.88 | 50 | 14.34 | 2930 | 2101 | 2.32 / 83.94 | 3 | 3 |
3 | 13 | 1386.40 | 25 | 14.50 | 2173 | 788 | 3.11 / 84.73 | 3 | 3 |
4 | 13 | 505.68 | 25 | 14.75 | 1040 | 383 | 3.49 / 85.12 | 3 | 4 |
5 | 8 | 0.12 | 165 | 14.86 | 333 | 816 | 4.31 / 85.93 | 3 | 10 |
6 | 14 | 0.12 | 30 | 14.84 | 333 | 148 | 4.46 / 86.08 | 3 | 9 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.32 | 31 | 14.81 | 492 | 226 | 0.23 / 77.52 | 3 | 3 |
2 | 7 | 2010.96 | 50 | 14.33 | 2963 | 2123 | 2.35 / 79.64 | 3 | 3 |
3 | 13 | 1391.16 | 25 | 14.50 | 2199 | 797 | 3.15 / 80.44 | 3 | 3 |
4 | 13 | 440.72 | 25 | 14.78 | 956 | 353 | 3.50 / 80.79 | 3 | 4 |
5 | 8 | 0.16 | 165 | 14.86 | 338 | 829 | 4.33 / 81.62 | 3 | 9 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 31 | 14.80 | 508 | 233 | 0.23 / 73.24 | 3 | 3 |
2 | 7 | 2009.76 | 50 | 14.35 | 2902 | 2082 | 2.32 / 75.32 | 3 | 3 |
3 | 13 | 1282.72 | 25 | 14.54 | 2052 | 746 | 3.06 / 76.07 | 3 | 3 |
4 | 13 | 536.00 | 25 | 14.75 | 1092 | 403 | 3.46 / 76.47 | 3 | 4 |
5 | 8 | -0.24 | 165 | 14.87 | 336 | 824 | 4.29 / 77.30 | 3 | 9 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 31 | 14.81 | 494 | 227 | 0.23 / 68.91 | 3 | 3 |
2 | 7 | 2002.48 | 50 | 14.35 | 2907 | 2086 | 2.31 / 71.00 | 3 | 3 |
3 | 13 | 1339.24 | 25 | 14.52 | 2137 | 776 | 3.09 / 71.78 | 3 | 3 |
4 | 13 | 420.64 | 25 | 14.79 | 944 | 349 | 3.44 / 72.12 | 3 | 4 |
5 | 8 | -0.04 | 165 | 14.86 | 360 | 883 | 4.32 / 73.01 | 3 | 12 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 31 | 14.81 | 486 | 223 | 0.22 / 64.65 | 3 | 3 |
2 | 7 | 2001.60 | 50 | 14.36 | 2894 | 2078 | 2.30 / 66.73 | 3 | 3 |
3 | 13 | 1384.32 | 25 | 14.52 | 2156 | 783 | 3.08 / 67.52 | 3 | 3 |
4 | 13 | 459.56 | 25 | 14.79 | 947 | 350 | 3.43 / 67.87 | 3 | 4 |
5 | 8 | 0.04 | 165 | 14.87 | 335 | 822 | 4.26 / 68.69 | 3 | 10 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 31 | 14.81 | 471 | 216 | 0.22 / 60.33 | 3 | 3 |
2 | 7 | 2003.48 | 50 | 14.35 | 2932 | 2104 | 2.32 / 62.43 | 3 | 3 |
3 | 13 | 1331.36 | 25 | 14.53 | 2095 | 761 | 3.08 / 63.19 | 3 | 3 |
4 | 13 | 571.96 | 25 | 14.74 | 1137 | 419 | 3.50 / 63.61 | 3 | 4 |
5 | 8 | -0.12 | 165 | 14.87 | 335 | 822 | 4.32 / 64.43 | 3 | 11 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 31 | 14.82 | 500 | 230 | 0.23 / 55.78 | 3 | 3 |
2 | 7 | 2012.44 | 50 | 14.35 | 2943 | 2112 | 2.34 / 57.89 | 3 | 3 |
3 | 13 | 1450.64 | 25 | 14.49 | 2246 | 814 | 3.15 / 58.71 | 3 | 3 |
4 | 13 | 603.28 | 25 | 14.73 | 1161 | 428 | 3.58 / 59.13 | 3 | 3 |
5 | 8 | 0.04 | 165 | 14.87 | 337 | 827 | 4.41 / 59.96 | 3 | 8 |
6 | 14 | 0.04 | 30 | 14.85 | 334 | 149 | 4.56 / 60.11 | 3 | 10 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 31 | 14.82 | 497 | 228 | 0.23 / 51.49 | 3 | 3 |
2 | 7 | 2005.88 | 50 | 14.36 | 2899 | 2081 | 2.31 / 53.57 | 3 | 3 |
3 | 13 | 1374.52 | 25 | 14.53 | 2146 | 780 | 3.09 / 54.35 | 3 | 3 |
4 | 13 | 496.20 | 25 | 14.78 | 1022 | 378 | 3.47 / 54.73 | 3 | 4 |
5 | 8 | -0.08 | 165 | 14.88 | 335 | 822 | 4.29 / 55.55 | 3 | 8 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 31 | 14.82 | 493 | 226 | 0.23 / 47.15 | 3 | 3 |
2 | 7 | 2005.16 | 50 | 14.37 | 2907 | 2089 | 2.32 / 49.24 | 3 | 3 |
3 | 13 | 1349.24 | 25 | 14.54 | 2106 | 766 | 3.08 / 50.00 | 3 | 3 |
4 | 13 | 593.16 | 25 | 14.74 | 1168 | 430 | 3.51 / 50.43 | 3 | 3 |
5 | 8 | 0.12 | 165 | 14.88 | 337 | 827 | 4.34 / 51.26 | 3 | 10 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 31 | 14.83 | 519 | 239 | 0.24 / 42.80 | 3 | 3 |
2 | 7 | 2011.12 | 50 | 14.36 | 2907 | 2087 | 2.33 / 44.89 | 3 | 3 |
3 | 13 | 1398.00 | 25 | 14.52 | 2188 | 794 | 3.12 / 45.68 | 3 | 3 |
4 | 13 | 570.64 | 25 | 14.75 | 1127 | 416 | 3.54 / 46.10 | 3 | 4 |
5 | 8 | -0.08 | 165 | 14.88 | 336 | 825 | 4.36 / 46.92 | 3 | 9 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 31 | 14.83 | 504 | 232 | 0.23 / 38.46 | 3 | 3 |
2 | 7 | 2009.44 | 74 | 14.30 | 2897 | 3066 | 3.30 / 41.53 | 3 | 3 |
3 | 13 | 384.40 | 18 | 14.83 | 846 | 226 | 3.52 / 41.75 | 3 | 3 |
4 | 8 | -0.04 | 165 | 14.90 | 330 | 811 | 4.33 / 42.56 | 3 | 11 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.48 | 31 | 14.84 | 510 | 235 | 0.23 / 34.11 | 3 | 3 |
2 | 7 | 2013.44 | 74 | 14.30 | 2904 | 3073 | 3.31 / 37.18 | 3 | 3 |
3 | 13 | 392.36 | 18 | 14.83 | 878 | 234 | 3.54 / 37.41 | 3 | 3 |
4 | 8 | 0.20 | 165 | 14.90 | 331 | 814 | 4.36 / 38.23 | 3 | 8 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 30 | 14.83 | 517 | 230 | 0.23 / 29.78 | 3 | 3 |
2 | 7 | 2009.04 | 74 | 14.31 | 2896 | 3067 | 3.30 / 32.84 | 3 | 3 |
3 | 13 | 391.68 | 18 | 14.83 | 858 | 229 | 3.53 / 33.07 | 3 | 3 |
4 | 8 | 0.00 | 165 | 14.90 | 326 | 801 | 4.33 / 33.87 | 3 | 11 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 30 | 14.83 | 511 | 227 | 0.23 / 25.39 | 3 | 3 |
2 | 3 | 1020.76 | 1 | 14.80 | 1770 | 26 | 0.25 / 25.41 | 3 | 3 |
3 | 7 | 2004.72 | 74 | 14.31 | 2893 | 3064 | 3.32 / 28.48 | 3 | 3 |
4 | 13 | 379.28 | 18 | 14.84 | 843 | 225 | 3.54 / 28.70 | 3 | 3 |
5 | 8 | 0.12 | 165 | 14.90 | 343 | 843 | 4.39 / 29.55 | 3 | 10 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 14.84 | 489 | 203 | 0.20 / 20.94 | 3 | 3 |
2 | 10 | 1023.48 | 2 | 14.73 | 1759 | 52 | 0.26 / 20.99 | 3 | 3 |
3 | 7 | 2002.80 | 74 | 14.31 | 2886 | 3056 | 3.31 / 24.05 | 3 | 3 |
4 | 13 | 380.64 | 18 | 14.83 | 871 | 233 | 3.54 / 24.28 | 3 | 3 |
5 | 8 | 0.24 | 165 | 14.89 | 359 | 882 | 4.43 / 25.16 | 3 | 9 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 28 | 14.83 | 507 | 211 | 0.21 / 16.63 | 3 | 3 |
2 | 7 | 2003.24 | 74 | 14.31 | 2894 | 3065 | 3.28 / 19.69 | 3 | 3 |
3 | 13 | 376.80 | 18 | 14.84 | 861 | 230 | 3.51 / 19.92 | 3 | 3 |
4 | 8 | 0.08 | 165 | 14.90 | 331 | 814 | 4.32 / 20.73 | 3 | 6 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 28 | 14.82 | 475 | 197 | 0.20 / 12.93 | 3 | 3 |
2 | 7 | 1507.72 | 74 | 14.48 | 2310 | 2475 | 2.67 / 15.40 | 3 | 3 |
3 | 13 | 121.76 | 18 | 14.90 | 513 | 138 | 2.81 / 15.54 | 3 | 3 |
4 | 8 | -0.04 | 165 | 14.89 | 356 | 875 | 3.68 / 16.42 | 3 | 7 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 27 | 14.82 | 467 | 187 | 0.19 / 8.97 | 3 | 3 |
2 | 3 | 1033.44 | 1 | 14.77 | 1808 | 27 | 0.21 / 8.99 | 3 | 3 |
3 | 7 | 1505.92 | 74 | 14.47 | 2303 | 2466 | 2.68 / 11.46 | 3 | 3 |
4 | 13 | 58.04 | 18 | 14.93 | 412 | 111 | 2.79 / 11.57 | 3 | 3 |
5 | 8 | 0.16 | 165 | 14.90 | 326 | 801 | 3.59 / 12.37 | 3 | 9 |
6 | 14 | 0.16 | 75 | 14.86 | 323 | 360 | 3.95 / 12.73 | 3 | 9 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 31 | 14.82 | 482 | 221 | 0.22 / 4.93 | 3 | 3 |
2 | 3 | 882.56 | -2 | 15.07 | 24 | 0 | 0.00 / 4.93 | 3 | 3 |
3 | 3 | 973.32 | -1 | 15.08 | 25 | 0 | 0.00 / 4.93 | 3 | 3 |
4 | 7 | 1506.00 | 74 | 14.47 | 2328 | 2493 | 2.71 / 7.43 | 3 | 3 |
5 | 13 | 63.60 | 18 | 14.92 | 422 | 113 | 2.83 / 7.54 | 3 | 3 |
6 | 8 | 0.00 | 165 | 14.89 | 349 | 857 | 3.68 / 8.40 | 3 | 7 |
7 | 14 | 0.00 | 75 | 14.85 | 343 | 382 | 4.07 / 8.78 | 3 | 10 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 26 | 14.91 | 482 | 187 | 0.19 / 2.02 | 3 | 3 |
2 | 10 | 1019.20 | 2 | 14.75 | 1757 | 52 | 0.24 / 2.07 | 3 | 3 |
3 | 7 | 995.48 | 74 | 14.63 | 1651 | 1787 | 2.03 / 3.86 | 3 | 3 |
4 | 8 | 0.00 | 165 | 14.88 | 347 | 852 | 2.88 / 4.71 | 3 | 8 |
Average= | 2.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 133.56 | 25 | 15.05 | 463 | 174 | 0.17 / 0.17 | 3 | 3 |
2 | 7 | 143.04 | 74 | 15.01 | 488 | 542 | 0.72 / 0.72 | 3 | 3 |
3 | 8 | 0.04 | 240 | 14.98 | 311 | 1118 | 1.83 / 1.83 | 3 | 10 |
Average= | 1.83 (KJ/cycle) |