SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 34 | 15.20 | 404 | 209 | 0.21 / 100.99 | 2 | 3 |
2 | 3 | 1095.40 | 3 | 15.20 | 1841 | 84 | 0.29 / 101.07 | 2 | 2 |
3 | 3 | 1049.92 | 1 | 15.25 | 1798 | 27 | 0.32 / 101.10 | 2 | 2 |
4 | 5 | 1383.84 | 11 | 15.14 | 2224 | 370 | 0.69 / 101.47 | 2 | 2 |
5 | 5 | 1306.20 | 9 | 15.19 | 2123 | 290 | 0.98 / 101.76 | 2 | 2 |
6 | 7 | 2039.36 | 34 | 14.87 | 2989 | 1511 | 2.49 / 103.27 | 2 | 2 |
7 | 13 | 2099.80 | 19 | 14.80 | 3082 | 867 | 3.36 / 104.14 | 2 | 3 |
8 | 13 | 1996.64 | 19 | 14.75 | 2930 | 821 | 4.18 / 104.96 | 2 | 3 |
9 | 13 | 1584.52 | 19 | 14.79 | 2417 | 679 | 4.86 / 105.64 | 2 | 3 |
10 | 13 | 1017.68 | 19 | 14.91 | 1680 | 476 | 5.33 / 106.11 | 2 | 3 |
11 | 13 | 304.40 | 19 | 15.10 | 723 | 207 | 5.54 / 106.32 | 2 | 2 |
12 | 13 | 141.92 | 19 | 15.14 | 476 | 137 | 5.68 / 106.46 | 2 | 2 |
13 | 8 | 0.16 | 165 | 15.13 | 269 | 672 | 6.35 / 107.13 | 2 | 45 |
14 | 14 | 0.16 | 30 | 15.10 | 265 | 120 | 6.47 / 107.25 | 2 | 31 |
Average= | 107.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 29 | 15.17 | 405 | 178 | 0.18 / 97.06 | 2 | 4 |
2 | 7 | 2012.52 | 34 | 14.92 | 2945 | 1494 | 1.67 / 98.56 | 2 | 2 |
3 | 13 | 1458.40 | 19 | 14.96 | 2262 | 643 | 2.32 / 99.20 | 2 | 2 |
4 | 13 | 1043.24 | 19 | 15.02 | 1706 | 487 | 2.80 / 99.69 | 2 | 3 |
5 | 13 | 297.80 | 19 | 15.20 | 713 | 206 | 3.01 / 99.89 | 2 | 4 |
6 | 13 | 115.08 | 19 | 15.22 | 438 | 127 | 3.13 / 100.02 | 2 | 3 |
7 | 13 | 28.48 | 19 | 15.23 | 316 | 91 | 3.23 / 100.11 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.20 | 267 | 670 | 3.90 / 100.78 | 2 | 8 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 29 | 15.19 | 413 | 182 | 0.18 / 93.20 | 2 | 3 |
2 | 7 | 2007.68 | 34 | 14.92 | 2943 | 1493 | 1.67 / 94.69 | 2 | 2 |
3 | 13 | 1583.20 | 19 | 14.94 | 2415 | 686 | 2.36 / 95.38 | 2 | 3 |
4 | 13 | 997.24 | 19 | 15.03 | 1654 | 472 | 2.83 / 95.85 | 2 | 3 |
5 | 13 | 384.96 | 19 | 15.17 | 828 | 239 | 3.07 / 96.09 | 2 | 4 |
6 | 13 | 134.52 | 19 | 15.22 | 464 | 134 | 3.21 / 96.23 | 2 | 8 |
7 | 8 | 0.16 | 165 | 15.22 | 262 | 658 | 3.86 / 96.88 | 2 | 31 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 29 | 15.17 | 421 | 185 | 0.19 / 89.44 | 2 | 2 |
2 | 7 | 2004.40 | 34 | 14.93 | 2941 | 1493 | 1.68 / 90.93 | 2 | 2 |
3 | 13 | 1583.96 | 19 | 14.96 | 2418 | 687 | 2.37 / 91.62 | 2 | 3 |
4 | 13 | 859.08 | 19 | 15.08 | 1471 | 421 | 2.79 / 92.04 | 2 | 3 |
5 | 13 | 290.28 | 19 | 15.21 | 688 | 199 | 2.99 / 92.24 | 2 | 2 |
6 | 13 | 121.52 | 19 | 15.23 | 438 | 127 | 3.11 / 92.37 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.22 | 260 | 653 | 3.77 / 93.02 | 2 | 27 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 29 | 15.20 | 407 | 179 | 0.18 / 85.65 | 2 | 2 |
2 | 7 | 2011.40 | 34 | 14.92 | 2950 | 1496 | 1.68 / 87.15 | 2 | 2 |
3 | 13 | 1345.36 | 19 | 14.99 | 2111 | 601 | 2.28 / 87.75 | 2 | 2 |
4 | 13 | 831.04 | 19 | 15.08 | 1427 | 409 | 2.69 / 88.16 | 2 | 3 |
5 | 13 | 260.28 | 19 | 15.21 | 659 | 190 | 2.88 / 88.35 | 2 | 2 |
6 | 13 | 157.88 | 19 | 15.21 | 499 | 144 | 3.02 / 88.50 | 2 | 2 |
7 | 13 | 17.96 | 19 | 15.24 | 299 | 87 | 3.11 / 88.58 | 2 | 14 |
8 | 8 | 0.12 | 165 | 15.20 | 268 | 672 | 3.78 / 89.25 | 2 | 6 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 29 | 15.17 | 408 | 179 | 0.18 / 81.93 | 2 | 2 |
2 | 7 | 2007.12 | 34 | 14.94 | 2942 | 1494 | 1.67 / 83.42 | 2 | 3 |
3 | 13 | 1345.92 | 19 | 15.00 | 2106 | 600 | 2.27 / 84.02 | 2 | 3 |
4 | 13 | 941.64 | 19 | 15.06 | 1571 | 450 | 2.72 / 84.47 | 2 | 2 |
5 | 13 | 322.84 | 19 | 15.19 | 747 | 216 | 2.94 / 84.69 | 2 | 2 |
6 | 13 | 124.36 | 19 | 15.23 | 445 | 129 | 3.07 / 84.82 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.22 | 262 | 658 | 3.73 / 85.48 | 2 | 22 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 29 | 15.18 | 419 | 184 | 0.18 / 78.10 | 2 | 2 |
2 | 7 | 2005.16 | 34 | 14.94 | 2931 | 1489 | 1.67 / 79.59 | 2 | 3 |
3 | 13 | 1454.16 | 19 | 14.99 | 2248 | 640 | 2.31 / 80.23 | 2 | 2 |
4 | 13 | 897.32 | 19 | 15.07 | 1519 | 435 | 2.75 / 80.67 | 2 | 3 |
5 | 13 | 445.96 | 19 | 15.17 | 915 | 264 | 3.01 / 80.93 | 2 | 3 |
6 | 13 | 150.72 | 19 | 15.22 | 490 | 142 | 3.15 / 81.07 | 2 | 6 |
7 | 8 | 0.12 | 165 | 15.22 | 269 | 676 | 3.83 / 81.75 | 2 | 16 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 29 | 15.20 | 409 | 180 | 0.18 / 74.25 | 2 | 2 |
2 | 7 | 2004.20 | 34 | 14.94 | 2936 | 1491 | 1.67 / 75.74 | 2 | 2 |
3 | 13 | 1428.84 | 19 | 15.00 | 2205 | 628 | 2.30 / 76.37 | 2 | 2 |
4 | 13 | 987.88 | 19 | 15.06 | 1637 | 468 | 2.77 / 76.84 | 2 | 3 |
5 | 13 | 249.72 | 19 | 15.23 | 648 | 188 | 2.96 / 77.03 | 2 | 2 |
6 | 13 | 138.60 | 19 | 15.24 | 477 | 138 | 3.09 / 77.17 | 2 | 2 |
7 | 13 | 16.88 | 19 | 15.26 | 298 | 86 | 3.18 / 77.25 | 2 | 10 |
8 | 8 | 0.08 | 165 | 15.22 | 266 | 668 | 3.85 / 77.92 | 2 | 6 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 29 | 15.20 | 406 | 179 | 0.18 / 70.49 | 2 | 2 |
2 | 3 | 1016.28 | 1 | 15.29 | 1749 | 27 | 0.21 / 70.51 | 2 | 2 |
3 | 7 | 2005.16 | 34 | 14.94 | 2939 | 1493 | 1.70 / 72.01 | 2 | 2 |
4 | 13 | 1451.44 | 19 | 14.99 | 2242 | 639 | 2.34 / 72.65 | 2 | 2 |
5 | 13 | 877.64 | 19 | 15.08 | 1492 | 427 | 2.76 / 73.07 | 2 | 2 |
6 | 13 | 292.12 | 19 | 15.22 | 705 | 204 | 2.97 / 73.28 | 2 | 4 |
7 | 13 | 128.40 | 19 | 15.24 | 451 | 131 | 3.10 / 73.41 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.23 | 264 | 663 | 3.76 / 74.07 | 2 | 7 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 29 | 15.21 | 412 | 182 | 0.18 / 66.64 | 2 | 2 |
2 | 7 | 2008.48 | 34 | 14.94 | 2937 | 1492 | 1.67 / 68.13 | 2 | 2 |
3 | 13 | 1545.04 | 19 | 14.97 | 2359 | 671 | 2.34 / 68.80 | 2 | 2 |
4 | 13 | 838.52 | 19 | 15.09 | 1445 | 414 | 2.76 / 69.22 | 2 | 3 |
5 | 13 | 263.76 | 19 | 15.21 | 661 | 191 | 2.95 / 69.41 | 2 | 2 |
6 | 13 | 141.20 | 19 | 15.23 | 477 | 138 | 3.09 / 69.55 | 2 | 3 |
7 | 13 | 36.76 | 19 | 15.26 | 328 | 95 | 3.18 / 69.64 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.22 | 266 | 668 | 3.85 / 70.31 | 2 | 13 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 28 | 15.21 | 409 | 174 | 0.17 / 62.81 | 2 | 2 |
2 | 7 | 2002.88 | 34 | 14.96 | 2928 | 1489 | 1.66 / 64.30 | 2 | 2 |
3 | 13 | 1446.44 | 19 | 15.01 | 2233 | 637 | 2.30 / 64.94 | 2 | 3 |
4 | 13 | 886.80 | 19 | 15.10 | 1501 | 431 | 2.73 / 65.37 | 2 | 3 |
5 | 13 | 294.28 | 19 | 15.22 | 704 | 204 | 2.93 / 65.57 | 2 | 3 |
6 | 13 | 130.80 | 19 | 15.25 | 454 | 132 | 3.07 / 65.71 | 2 | 3 |
7 | 13 | 33.00 | 19 | 15.27 | 314 | 91 | 3.16 / 65.80 | 2 | 12 |
8 | 8 | 0.16 | 165 | 15.23 | 263 | 661 | 3.82 / 66.46 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 28 | 15.21 | 423 | 180 | 0.18 / 59.07 | 2 | 2 |
2 | 7 | 2010.28 | 34 | 14.94 | 2945 | 1496 | 1.68 / 60.57 | 2 | 2 |
3 | 13 | 1446.40 | 19 | 15.00 | 2232 | 636 | 2.31 / 61.20 | 2 | 2 |
4 | 13 | 883.88 | 19 | 15.09 | 1500 | 430 | 2.74 / 61.63 | 2 | 3 |
5 | 13 | 290.32 | 19 | 15.22 | 697 | 202 | 2.94 / 61.83 | 2 | 2 |
6 | 13 | 169.12 | 19 | 15.23 | 513 | 148 | 3.09 / 61.98 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.24 | 261 | 656 | 3.75 / 62.64 | 2 | 8 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.68 | 28 | 15.21 | 401 | 171 | 0.17 / 55.28 | 2 | 2 |
2 | 7 | 2006.08 | 34 | 14.96 | 2933 | 1492 | 1.66 / 56.77 | 2 | 3 |
3 | 13 | 1455.92 | 19 | 15.01 | 2240 | 639 | 2.30 / 57.41 | 2 | 2 |
4 | 13 | 894.92 | 19 | 15.09 | 1517 | 435 | 2.74 / 57.84 | 2 | 4 |
5 | 13 | 211.08 | 19 | 15.25 | 578 | 167 | 2.90 / 58.01 | 2 | 2 |
6 | 13 | 119.48 | 19 | 15.26 | 446 | 129 | 3.03 / 58.14 | 2 | 2 |
7 | 13 | 34.12 | 19 | 15.27 | 318 | 92 | 3.13 / 58.23 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.24 | 262 | 659 | 3.78 / 58.89 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 28 | 15.22 | 405 | 173 | 0.17 / 51.39 | 2 | 2 |
2 | 7 | 2005.68 | 34 | 14.96 | 2933 | 1492 | 1.66 / 52.88 | 2 | 2 |
3 | 13 | 1595.00 | 19 | 14.99 | 2425 | 691 | 2.36 / 53.57 | 2 | 2 |
4 | 13 | 888.32 | 19 | 15.11 | 1504 | 432 | 2.79 / 54.00 | 2 | 3 |
5 | 13 | 291.64 | 19 | 15.24 | 694 | 201 | 2.99 / 54.20 | 2 | 3 |
6 | 13 | 166.32 | 19 | 15.25 | 514 | 149 | 3.14 / 54.35 | 2 | 2 |
7 | 13 | 40.32 | 19 | 15.28 | 326 | 95 | 3.23 / 54.45 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.25 | 262 | 659 | 3.89 / 55.11 | 2 | 4 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 28 | 15.24 | 410 | 175 | 0.17 / 47.59 | 2 | 2 |
2 | 7 | 2006.52 | 34 | 14.97 | 2929 | 1491 | 1.67 / 49.08 | 2 | 3 |
3 | 13 | 1459.16 | 19 | 15.02 | 2253 | 643 | 2.31 / 49.73 | 2 | 2 |
4 | 13 | 878.76 | 19 | 15.12 | 1495 | 429 | 2.74 / 50.16 | 2 | 3 |
5 | 13 | 292.12 | 19 | 15.24 | 697 | 202 | 2.94 / 50.36 | 2 | 3 |
6 | 13 | 113.04 | 19 | 15.27 | 424 | 123 | 3.06 / 50.48 | 2 | 2 |
7 | 13 | 33.32 | 19 | 15.28 | 311 | 90 | 3.15 / 50.57 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.25 | 256 | 644 | 3.80 / 51.22 | 2 | 9 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 28 | 15.24 | 405 | 173 | 0.17 / 43.74 | 2 | 2 |
2 | 7 | 2007.08 | 34 | 14.98 | 2935 | 1495 | 1.67 / 45.23 | 2 | 2 |
3 | 13 | 1556.96 | 19 | 15.02 | 2368 | 676 | 2.34 / 45.91 | 2 | 3 |
4 | 13 | 942.48 | 19 | 15.11 | 1574 | 452 | 2.80 / 46.36 | 2 | 3 |
5 | 13 | 222.08 | 19 | 15.28 | 602 | 175 | 2.97 / 46.54 | 2 | 2 |
6 | 13 | 130.20 | 19 | 15.29 | 452 | 131 | 3.10 / 46.67 | 2 | 4 |
7 | 13 | 68.20 | 19 | 15.29 | 359 | 104 | 3.21 / 46.77 | 2 | 2 |
8 | 8 | -0.04 | 165 | 15.26 | 257 | 647 | 3.85 / 47.42 | 2 | 3 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 28 | 15.23 | 405 | 173 | 0.17 / 39.88 | 2 | 2 |
2 | 7 | 2006.40 | 34 | 14.98 | 2929 | 1492 | 1.66 / 41.37 | 2 | 2 |
3 | 13 | 1573.64 | 19 | 15.00 | 2390 | 681 | 2.35 / 42.05 | 2 | 2 |
4 | 13 | 962.36 | 19 | 15.10 | 1607 | 461 | 2.81 / 42.51 | 2 | 3 |
5 | 13 | 229.20 | 19 | 15.26 | 613 | 178 | 2.98 / 42.69 | 2 | 4 |
6 | 13 | 133.44 | 19 | 15.27 | 460 | 133 | 3.12 / 42.82 | 2 | 2 |
7 | 13 | 33.60 | 19 | 15.29 | 312 | 91 | 3.21 / 42.91 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.26 | 259 | 652 | 3.86 / 43.57 | 2 | 4 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 28 | 15.23 | 405 | 173 | 0.17 / 36.01 | 2 | 2 |
2 | 7 | 2007.80 | 34 | 14.98 | 2946 | 1500 | 1.67 / 37.51 | 2 | 2 |
3 | 13 | 1589.52 | 18 | 15.02 | 2415 | 653 | 2.33 / 38.16 | 2 | 2 |
4 | 13 | 983.92 | 18 | 15.12 | 1632 | 444 | 2.77 / 38.61 | 2 | 3 |
5 | 13 | 381.32 | 18 | 15.23 | 822 | 225 | 3.00 / 38.83 | 2 | 3 |
6 | 13 | 142.00 | 18 | 15.28 | 476 | 131 | 3.13 / 38.96 | 2 | 2 |
7 | 13 | 19.76 | 18 | 15.30 | 300 | 83 | 3.21 / 39.05 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.27 | 262 | 660 | 3.87 / 39.71 | 2 | 5 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 28 | 15.23 | 402 | 171 | 0.17 / 32.14 | 2 | 2 |
2 | 7 | 2003.12 | 34 | 14.98 | 2926 | 1490 | 1.66 / 33.63 | 2 | 2 |
3 | 13 | 1439.00 | 18 | 15.04 | 2229 | 603 | 2.27 / 34.23 | 2 | 2 |
4 | 13 | 1154.84 | 18 | 15.07 | 1859 | 504 | 2.77 / 34.74 | 2 | 2 |
5 | 13 | 368.52 | 18 | 15.24 | 805 | 221 | 2.99 / 34.96 | 2 | 2 |
6 | 13 | 151.32 | 18 | 15.27 | 487 | 134 | 3.12 / 35.09 | 2 | 3 |
7 | 13 | 38.76 | 18 | 15.29 | 324 | 89 | 3.21 / 35.18 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.26 | 260 | 655 | 3.87 / 35.84 | 2 | 4 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 28 | 15.25 | 405 | 173 | 0.17 / 28.35 | 2 | 2 |
2 | 7 | 2005.44 | 33 | 14.99 | 2924 | 1446 | 1.62 / 29.79 | 2 | 2 |
3 | 13 | 1589.56 | 18 | 15.03 | 2399 | 649 | 2.27 / 30.44 | 2 | 3 |
4 | 13 | 878.00 | 18 | 15.14 | 1473 | 401 | 2.67 / 30.85 | 2 | 3 |
5 | 13 | 432.20 | 18 | 15.23 | 867 | 238 | 2.91 / 31.08 | 2 | 3 |
6 | 13 | 141.08 | 18 | 15.27 | 474 | 130 | 3.04 / 31.21 | 2 | 2 |
7 | 13 | 39.36 | 18 | 15.30 | 327 | 90 | 3.13 / 31.30 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.26 | 264 | 665 | 3.79 / 31.97 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 27 | 15.26 | 413 | 170 | 0.17 / 23.86 | 2 | 2 |
2 | 3 | 1043.72 | 1 | 15.31 | 1779 | 27 | 0.20 / 23.89 | 2 | 2 |
3 | 7 | 2009.68 | 74 | 14.84 | 2923 | 3210 | 3.41 / 27.10 | 2 | 2 |
4 | 13 | 346.08 | 18 | 15.26 | 773 | 212 | 3.62 / 27.31 | 2 | 2 |
5 | 13 | 133.76 | 18 | 15.30 | 459 | 126 | 3.75 / 27.44 | 2 | 2 |
6 | 13 | 15.48 | 18 | 15.32 | 291 | 80 | 3.83 / 27.52 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.29 | 261 | 658 | 4.48 / 28.18 | 2 | 4 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 26 | 15.26 | 392 | 156 | 0.16 / 19.39 | 2 | 2 |
2 | 10 | 1009.48 | 2 | 15.28 | 1681 | 51 | 0.21 / 19.44 | 2 | 2 |
3 | 3 | 972.32 | -1 | 15.59 | 0 | 0 | 0.05 / 19.44 | 2 | 2 |
4 | 7 | 2006.32 | 74 | 14.85 | 2911 | 3199 | 3.41 / 22.64 | 2 | 2 |
5 | 13 | 327.00 | 18 | 15.28 | 723 | 199 | 3.60 / 22.84 | 2 | 2 |
6 | 13 | 132.08 | 18 | 15.30 | 438 | 121 | 3.73 / 22.96 | 2 | 2 |
7 | 13 | 35.12 | 18 | 15.32 | 295 | 81 | 3.81 / 23.04 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.30 | 257 | 649 | 4.46 / 23.69 | 2 | 8 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 29 | 15.28 | 400 | 177 | 0.18 / 14.97 | 2 | 2 |
2 | 3 | 920.48 | -2 | 15.59 | 0 | 0 | 0.00 / 14.97 | 2 | 2 |
3 | 7 | 2005.24 | 74 | 14.85 | 2905 | 3192 | 3.37 / 18.16 | 2 | 2 |
4 | 13 | 337.80 | 18 | 15.28 | 753 | 207 | 3.58 / 18.37 | 2 | 2 |
5 | 13 | 138.64 | 18 | 15.30 | 457 | 126 | 3.70 / 18.49 | 2 | 2 |
6 | 13 | 72.32 | 18 | 15.31 | 361 | 99 | 3.80 / 18.59 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.29 | 255 | 643 | 4.45 / 19.24 | 2 | 6 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 26 | 15.28 | 406 | 161 | 0.16 / 11.32 | 2 | 2 |
2 | 3 | 1018.52 | 1 | 15.34 | 1732 | 27 | 0.19 / 11.34 | 2 | 2 |
3 | 7 | 1520.64 | 74 | 15.03 | 2296 | 2554 | 2.74 / 13.90 | 2 | 2 |
4 | 13 | 183.16 | 18 | 15.33 | 526 | 145 | 2.89 / 14.04 | 2 | 2 |
5 | 13 | 113.20 | 18 | 15.33 | 417 | 115 | 3.00 / 14.16 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.32 | 251 | 634 | 3.64 / 14.79 | 2 | 5 |
Average= | 2.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 25 | 15.27 | 389 | 149 | 0.15 / 7.71 | 2 | 2 |
2 | 10 | 1031.00 | 2 | 15.27 | 1715 | 52 | 0.20 / 7.76 | 2 | 2 |
3 | 7 | 1507.08 | 74 | 15.03 | 2273 | 2528 | 2.73 / 10.29 | 2 | 3 |
4 | 13 | 164.44 | 18 | 15.34 | 496 | 137 | 2.87 / 10.42 | 2 | 2 |
5 | 13 | 92.96 | 18 | 15.34 | 387 | 107 | 2.97 / 10.53 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.32 | 247 | 624 | 3.60 / 11.15 | 2 | 4 |
Average= | 2.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 31 | 15.32 | 384 | 182 | 0.18 / 4.14 | 2 | 2 |
2 | 3 | 810.08 | -4 | 15.61 | 0 | 0 | 0.00 / 4.14 | 2 | 2 |
3 | 3 | 933.40 | -1 | 15.63 | 0 | 0 | 0.00 / 4.14 | 2 | 2 |
4 | 7 | 1515.56 | 74 | 15.05 | 2285 | 2545 | 2.73 / 6.68 | 2 | 2 |
5 | 13 | 176.40 | 18 | 15.33 | 506 | 140 | 2.87 / 6.82 | 2 | 2 |
6 | 13 | 121.16 | 18 | 15.33 | 422 | 116 | 2.98 / 6.94 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.31 | 245 | 619 | 3.60 / 7.56 | 2 | 5 |
Average= | 2.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 26 | 15.47 | 347 | 140 | 0.14 / 1.56 | 3 | 3 |
2 | 7 | 986.44 | 74 | 15.21 | 1577 | 1775 | 1.91 / 3.33 | 2 | 3 |
3 | 8 | 0.16 | 165 | 15.36 | 245 | 621 | 2.54 / 3.95 | 2 | 5 |
Average= | 1.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 166.04 | 26 | 15.59 | 426 | 173 | 0.17 / 0.17 | 3 | 3 |
2 | 7 | 179.80 | 75 | 15.56 | 436 | 509 | 0.68 / 0.68 | 3 | 3 |
3 | 8 | 0.08 | 240 | 15.52 | 198 | 738 | 1.42 / 1.42 | 3 | 7 |
Average= | 1.42 (KJ/cycle) |