SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 29 | 14.98 | 387 | 168 | 0.17 / 454.49 | 2 | 2 |
2 | 7 | 1171.20 | 31 | 15.05 | 1783 | 832 | 1.00 / 455.32 | 2 | 3 |
3 | 13 | 1146.00 | 18 | 14.99 | 1765 | 476 | 1.48 / 455.80 | 2 | 3 |
4 | 13 | 1026.80 | 18 | 14.97 | 1608 | 433 | 1.91 / 456.23 | 2 | 3 |
5 | 13 | 452.48 | 18 | 15.00 | 872 | 235 | 2.14 / 456.47 | 2 | 3 |
6 | 13 | 64.40 | 18 | 15.04 | 344 | 93 | 2.24 / 456.56 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.02 | 248 | 615 | 2.85 / 457.18 | 2 | 7 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.24 | 29 | 14.96 | 392 | 170 | 0.17 / 451.69 | 2 | 3 |
2 | 7 | 1182.40 | 31 | 15.05 | 1796 | 838 | 1.01 / 452.53 | 2 | 3 |
3 | 13 | 1148.32 | 18 | 15.01 | 1757 | 475 | 1.48 / 453.00 | 2 | 2 |
4 | 13 | 1027.68 | 18 | 14.97 | 1608 | 433 | 1.92 / 453.44 | 2 | 3 |
5 | 13 | 329.28 | 18 | 15.02 | 705 | 191 | 2.11 / 453.63 | 2 | 3 |
6 | 13 | 48.92 | 18 | 15.04 | 318 | 86 | 2.19 / 453.71 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.02 | 246 | 610 | 2.80 / 454.32 | 2 | 7 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 29 | 14.97 | 392 | 170 | 0.17 / 448.86 | 2 | 2 |
2 | 7 | 1234.96 | 31 | 15.04 | 1859 | 867 | 1.04 / 449.73 | 2 | 2 |
3 | 13 | 1187.84 | 18 | 14.99 | 1809 | 488 | 1.53 / 450.22 | 2 | 3 |
4 | 13 | 946.52 | 18 | 14.97 | 1506 | 406 | 1.93 / 450.63 | 2 | 3 |
5 | 13 | 392.32 | 18 | 15.01 | 787 | 213 | 2.14 / 450.84 | 2 | 3 |
6 | 13 | 28.48 | 18 | 15.05 | 293 | 79 | 2.22 / 450.92 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.01 | 244 | 604 | 2.83 / 451.52 | 2 | 5 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.48 | 29 | 14.96 | 396 | 172 | 0.17 / 446.05 | 2 | 2 |
2 | 7 | 1283.16 | 31 | 15.03 | 1917 | 893 | 1.06 / 446.94 | 2 | 3 |
3 | 13 | 1227.44 | 18 | 14.98 | 1862 | 502 | 1.57 / 447.45 | 2 | 2 |
4 | 13 | 976.80 | 18 | 14.95 | 1543 | 415 | 1.98 / 447.86 | 2 | 3 |
5 | 13 | 423.20 | 18 | 14.99 | 827 | 223 | 2.21 / 448.08 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.02 | 246 | 610 | 2.82 / 448.69 | 2 | 7 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 29 | 14.97 | 392 | 170 | 0.17 / 443.06 | 2 | 2 |
2 | 7 | 1356.00 | 31 | 15.01 | 2005 | 933 | 1.10 / 443.99 | 2 | 3 |
3 | 13 | 1283.40 | 18 | 14.96 | 1932 | 520 | 1.62 / 444.51 | 2 | 2 |
4 | 13 | 1036.40 | 18 | 14.93 | 1625 | 437 | 2.06 / 444.95 | 2 | 3 |
5 | 13 | 462.96 | 18 | 14.98 | 882 | 238 | 2.30 / 445.19 | 2 | 3 |
6 | 13 | 33.56 | 18 | 15.03 | 302 | 82 | 2.38 / 445.27 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.00 | 247 | 611 | 2.99 / 445.88 | 2 | 5 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 29 | 14.96 | 411 | 178 | 0.18 / 439.97 | 2 | 2 |
2 | 7 | 1343.44 | 31 | 15.02 | 1997 | 930 | 1.11 / 440.90 | 2 | 3 |
3 | 13 | 1287.08 | 18 | 14.96 | 1940 | 522 | 1.63 / 441.42 | 2 | 3 |
4 | 13 | 1163.64 | 18 | 14.93 | 1780 | 478 | 2.11 / 441.90 | 2 | 3 |
5 | 13 | 577.84 | 18 | 14.97 | 1038 | 280 | 2.39 / 442.18 | 2 | 3 |
6 | 13 | 54.40 | 18 | 15.03 | 330 | 89 | 2.48 / 442.27 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.00 | 249 | 616 | 3.09 / 442.89 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 29 | 14.94 | 401 | 174 | 0.17 / 436.80 | 2 | 2 |
2 | 7 | 1424.12 | 32 | 14.98 | 2098 | 1006 | 1.18 / 437.80 | 2 | 3 |
3 | 13 | 1343.00 | 18 | 14.93 | 2025 | 544 | 1.72 / 438.35 | 2 | 3 |
4 | 13 | 964.32 | 18 | 14.94 | 1546 | 416 | 2.14 / 438.76 | 2 | 3 |
5 | 13 | 422.40 | 18 | 14.99 | 831 | 224 | 2.36 / 438.99 | 2 | 3 |
6 | 13 | 28.96 | 18 | 15.03 | 297 | 80 | 2.44 / 439.07 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.01 | 248 | 614 | 3.06 / 439.68 | 2 | 4 |
8 | 14 | 0.04 | 30 | 14.99 | 248 | 112 | 3.17 / 439.79 | 2 | 9 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 29 | 14.93 | 393 | 170 | 0.17 / 433.13 | 2 | 2 |
2 | 7 | 1811.60 | 31 | 14.85 | 2597 | 1196 | 1.37 / 434.33 | 2 | 3 |
3 | 13 | 1684.16 | 18 | 14.81 | 2460 | 656 | 2.02 / 434.98 | 2 | 2 |
4 | 13 | 1241.16 | 18 | 14.82 | 1894 | 505 | 2.53 / 435.49 | 2 | 3 |
5 | 13 | 646.60 | 18 | 14.89 | 1133 | 304 | 2.83 / 435.79 | 2 | 3 |
6 | 13 | 96.24 | 18 | 14.98 | 387 | 104 | 2.93 / 435.90 | 2 | 3 |
7 | 8 | -0.04 | 165 | 14.97 | 250 | 618 | 3.55 / 436.52 | 2 | 7 |
8 | 14 | -0.04 | 30 | 14.95 | 244 | 109 | 3.66 / 436.62 | 3 | 8 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 29 | 14.94 | 399 | 173 | 0.17 / 429.45 | 2 | 2 |
2 | 7 | 2010.92 | 32 | 14.81 | 2830 | 1341 | 1.51 / 430.79 | 2 | 3 |
3 | 13 | 1738.88 | 18 | 14.77 | 2510 | 667 | 2.18 / 431.46 | 2 | 2 |
4 | 13 | 1150.72 | 18 | 14.80 | 1795 | 478 | 2.66 / 431.94 | 2 | 3 |
5 | 13 | 593.24 | 18 | 14.88 | 1057 | 283 | 2.94 / 432.22 | 2 | 3 |
6 | 13 | 150.08 | 18 | 14.96 | 459 | 124 | 3.07 / 432.35 | 2 | 3 |
7 | 8 | 0.12 | 165 | 14.97 | 250 | 618 | 3.68 / 432.96 | 2 | 6 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 30 | 14.93 | 384 | 172 | 0.17 / 425.77 | 2 | 2 |
2 | 3 | 957.16 | -1 | 15.26 | 1 | 0 | 0.00 / 425.77 | 2 | 2 |
3 | 7 | 2003.08 | 31 | 14.81 | 2814 | 1292 | 1.46 / 427.07 | 2 | 3 |
4 | 13 | 1601.88 | 18 | 14.78 | 2346 | 624 | 2.09 / 427.69 | 2 | 3 |
5 | 13 | 1170.48 | 18 | 14.80 | 1804 | 481 | 2.57 / 428.17 | 2 | 3 |
6 | 13 | 602.64 | 18 | 14.87 | 1073 | 287 | 2.86 / 428.46 | 2 | 3 |
7 | 13 | 79.80 | 18 | 14.97 | 366 | 99 | 2.95 / 428.56 | 2 | 3 |
8 | 8 | -0.04 | 165 | 14.97 | 248 | 613 | 3.57 / 429.17 | 2 | 5 |
9 | 14 | -0.04 | 30 | 14.95 | 246 | 110 | 3.68 / 429.28 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 29 | 14.93 | 397 | 172 | 0.17 / 422.04 | 2 | 2 |
2 | 3 | 1044.40 | 1 | 15.02 | 1676 | 25 | 0.20 / 422.06 | 2 | 2 |
3 | 3 | 1017.36 | 1 | 15.06 | 1685 | 25 | 0.22 / 422.09 | 2 | 2 |
4 | 7 | 2004.76 | 31 | 14.80 | 2819 | 1293 | 1.52 / 423.38 | 2 | 2 |
5 | 13 | 1607.44 | 18 | 14.78 | 2354 | 626 | 2.14 / 424.01 | 2 | 2 |
6 | 13 | 1185.32 | 18 | 14.80 | 1827 | 487 | 2.63 / 424.49 | 2 | 3 |
7 | 13 | 598.52 | 18 | 14.88 | 1067 | 286 | 2.91 / 424.78 | 2 | 3 |
8 | 13 | 78.68 | 18 | 14.98 | 364 | 98 | 3.01 / 424.88 | 2 | 3 |
9 | 8 | 0.32 | 165 | 14.97 | 249 | 615 | 3.63 / 425.49 | 2 | 6 |
10 | 14 | 0.32 | 30 | 14.95 | 247 | 111 | 3.74 / 425.60 | 3 | 17 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 29 | 14.94 | 397 | 172 | 0.17 / 418.45 | 2 | 2 |
2 | 7 | 2006.76 | 31 | 14.81 | 2818 | 1294 | 1.47 / 419.74 | 2 | 2 |
3 | 13 | 1606.28 | 18 | 14.79 | 2358 | 628 | 2.09 / 420.37 | 2 | 3 |
4 | 13 | 1186.84 | 18 | 14.80 | 1837 | 489 | 2.58 / 420.86 | 2 | 3 |
5 | 13 | 606.88 | 18 | 14.90 | 1079 | 289 | 2.87 / 421.15 | 2 | 3 |
6 | 13 | 74.96 | 18 | 14.99 | 360 | 97 | 2.97 / 421.25 | 2 | 2 |
7 | 8 | 0.00 | 165 | 14.97 | 250 | 618 | 3.59 / 421.86 | 2 | 9 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 29 | 14.94 | 390 | 169 | 0.17 / 414.86 | 2 | 2 |
2 | 7 | 2005.52 | 31 | 14.82 | 2822 | 1296 | 1.47 / 416.15 | 2 | 3 |
3 | 13 | 1722.80 | 18 | 14.78 | 2496 | 664 | 2.13 / 416.82 | 2 | 3 |
4 | 13 | 1148.40 | 18 | 14.81 | 1772 | 472 | 2.60 / 417.29 | 2 | 3 |
5 | 13 | 570.60 | 18 | 14.90 | 1029 | 276 | 2.88 / 417.57 | 2 | 3 |
6 | 13 | 62.76 | 18 | 14.99 | 341 | 92 | 2.97 / 417.66 | 2 | 3 |
7 | 8 | 0.00 | 165 | 14.98 | 250 | 618 | 3.59 / 418.28 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.32 | 29 | 14.92 | 398 | 172 | 0.17 / 411.28 | 2 | 2 |
2 | 7 | 2008.00 | 31 | 14.82 | 2822 | 1296 | 1.47 / 412.58 | 2 | 2 |
3 | 13 | 1609.40 | 18 | 14.77 | 2352 | 625 | 2.09 / 413.21 | 2 | 3 |
4 | 13 | 1198.44 | 18 | 14.80 | 1838 | 490 | 2.58 / 413.70 | 2 | 3 |
5 | 13 | 526.48 | 18 | 14.90 | 978 | 262 | 2.85 / 413.96 | 2 | 3 |
6 | 13 | 112.76 | 18 | 14.97 | 412 | 111 | 2.96 / 414.07 | 2 | 2 |
7 | 8 | 0.08 | 165 | 14.97 | 251 | 620 | 3.58 / 414.69 | 2 | 7 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 29 | 14.93 | 394 | 171 | 0.17 / 407.70 | 2 | 2 |
2 | 7 | 2006.24 | 31 | 14.80 | 2816 | 1292 | 1.46 / 408.99 | 2 | 2 |
3 | 13 | 1613.44 | 18 | 14.78 | 2359 | 628 | 2.09 / 409.62 | 2 | 3 |
4 | 13 | 1188.40 | 18 | 14.80 | 1830 | 488 | 2.58 / 410.11 | 2 | 3 |
5 | 13 | 594.72 | 18 | 14.89 | 1062 | 285 | 2.86 / 410.39 | 2 | 2 |
6 | 13 | 69.36 | 18 | 14.99 | 357 | 96 | 2.96 / 410.49 | 2 | 3 |
7 | 8 | 0.28 | 165 | 14.97 | 253 | 625 | 3.58 / 411.11 | 2 | 8 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 30 | 14.94 | 401 | 180 | 0.18 / 404.12 | 2 | 2 |
2 | 7 | 2004.80 | 31 | 14.81 | 2818 | 1294 | 1.47 / 405.42 | 2 | 3 |
3 | 13 | 1601.08 | 18 | 14.78 | 2354 | 626 | 2.10 / 406.04 | 2 | 3 |
4 | 13 | 1166.80 | 18 | 14.80 | 1809 | 482 | 2.58 / 406.53 | 2 | 3 |
5 | 13 | 596.36 | 18 | 14.88 | 1076 | 288 | 2.87 / 406.81 | 2 | 3 |
6 | 13 | 72.96 | 18 | 14.98 | 357 | 96 | 2.97 / 406.91 | 2 | 3 |
7 | 8 | -0.08 | 165 | 14.97 | 250 | 618 | 3.58 / 407.53 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 30 | 14.93 | 407 | 182 | 0.18 / 400.54 | 2 | 2 |
2 | 7 | 2006.16 | 31 | 14.83 | 2816 | 1295 | 1.48 / 401.84 | 2 | 2 |
3 | 13 | 1620.84 | 18 | 14.79 | 2366 | 630 | 2.11 / 402.47 | 2 | 2 |
4 | 13 | 1197.28 | 18 | 14.80 | 1843 | 491 | 2.60 / 402.96 | 2 | 3 |
5 | 13 | 512.20 | 18 | 14.90 | 960 | 257 | 2.86 / 403.22 | 2 | 3 |
6 | 13 | 107.32 | 18 | 14.98 | 403 | 109 | 2.96 / 403.32 | 2 | 2 |
7 | 8 | 0.12 | 165 | 14.97 | 251 | 620 | 3.58 / 403.94 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 30 | 14.94 | 408 | 183 | 0.18 / 396.91 | 2 | 2 |
2 | 3 | 1016.12 | 1 | 15.08 | 1658 | 25 | 0.21 / 396.93 | 2 | 2 |
3 | 7 | 2010.52 | 31 | 14.81 | 2829 | 1299 | 1.51 / 398.23 | 2 | 3 |
4 | 13 | 1732.52 | 18 | 14.77 | 2502 | 665 | 2.17 / 398.90 | 2 | 3 |
5 | 13 | 1048.92 | 18 | 14.82 | 1647 | 439 | 2.61 / 399.34 | 2 | 3 |
6 | 13 | 632.20 | 18 | 14.87 | 1111 | 297 | 2.91 / 399.64 | 2 | 3 |
7 | 13 | 89.56 | 18 | 14.98 | 380 | 102 | 3.01 / 399.74 | 2 | 3 |
8 | 8 | 0.28 | 165 | 14.97 | 252 | 622 | 3.63 / 400.36 | 2 | 7 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 30 | 14.94 | 389 | 174 | 0.17 / 393.25 | 2 | 2 |
2 | 3 | 979.24 | -1 | 15.36 | 0 | 0 | 0.00 / 393.25 | 2 | 2 |
3 | 7 | 2005.36 | 31 | 14.82 | 2821 | 1296 | 1.47 / 394.55 | 2 | 2 |
4 | 13 | 1616.48 | 18 | 14.79 | 2357 | 627 | 2.10 / 395.17 | 2 | 3 |
5 | 13 | 1196.12 | 18 | 14.79 | 1834 | 488 | 2.59 / 395.66 | 2 | 3 |
6 | 13 | 747.32 | 18 | 14.85 | 1258 | 336 | 2.92 / 396.00 | 2 | 3 |
7 | 13 | 137.88 | 18 | 14.97 | 442 | 119 | 3.04 / 396.12 | 2 | 3 |
8 | 8 | -0.16 | 165 | 14.97 | 247 | 610 | 3.65 / 396.73 | 2 | 8 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 31 | 14.93 | 397 | 184 | 0.18 / 389.68 | 2 | 2 |
2 | 7 | 2002.64 | 31 | 14.82 | 2814 | 1293 | 1.48 / 390.97 | 2 | 3 |
3 | 13 | 1593.04 | 18 | 14.80 | 2331 | 621 | 2.10 / 391.59 | 2 | 3 |
4 | 13 | 1175.60 | 18 | 14.81 | 1803 | 481 | 2.58 / 392.07 | 2 | 3 |
5 | 13 | 607.04 | 18 | 14.88 | 1079 | 289 | 2.87 / 392.36 | 2 | 3 |
6 | 13 | 87.24 | 18 | 14.98 | 375 | 101 | 2.97 / 392.46 | 2 | 4 |
7 | 8 | 0.04 | 165 | 14.98 | 248 | 613 | 3.58 / 393.08 | 2 | 8 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 31 | 14.94 | 400 | 185 | 0.19 / 386.06 | 2 | 2 |
2 | 3 | 972.36 | -1 | 15.34 | 0 | 0 | 0.00 / 386.06 | 2 | 2 |
3 | 3 | 1016.92 | 1 | 15.12 | 1663 | 25 | 0.21 / 386.09 | 2 | 2 |
4 | 7 | 2003.64 | 31 | 14.82 | 2821 | 1296 | 1.51 / 387.38 | 2 | 3 |
5 | 13 | 1608.20 | 18 | 14.78 | 2363 | 629 | 2.14 / 388.01 | 2 | 2 |
6 | 13 | 1183.84 | 18 | 14.79 | 1820 | 485 | 2.62 / 388.50 | 2 | 3 |
7 | 13 | 608.88 | 18 | 14.88 | 1082 | 290 | 2.91 / 388.79 | 2 | 3 |
8 | 13 | 83.88 | 18 | 14.98 | 370 | 100 | 3.01 / 388.89 | 2 | 4 |
9 | 8 | 0.12 | 165 | 14.97 | 246 | 608 | 3.62 / 389.49 | 2 | 7 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 30 | 14.98 | 392 | 176 | 0.18 / 382.30 | 2 | 3 |
2 | 10 | 1008.48 | 2 | 15.03 | 1647 | 50 | 0.23 / 382.35 | 2 | 2 |
3 | 3 | 975.12 | -1 | 15.33 | 0 | 0 | 0.05 / 382.35 | 2 | 2 |
4 | 3 | 1016.84 | 1 | 15.10 | 1654 | 25 | 0.25 / 382.37 | 2 | 2 |
5 | 7 | 2008.80 | 31 | 14.83 | 2832 | 1302 | 1.55 / 383.68 | 2 | 2 |
6 | 13 | 1734.08 | 18 | 14.79 | 2504 | 667 | 2.22 / 384.34 | 2 | 2 |
7 | 13 | 1163.64 | 18 | 14.82 | 1797 | 479 | 2.70 / 384.82 | 2 | 3 |
8 | 13 | 739.20 | 18 | 14.87 | 1252 | 335 | 3.03 / 385.16 | 2 | 3 |
9 | 13 | 135.44 | 18 | 14.97 | 435 | 117 | 3.15 / 385.27 | 2 | 3 |
10 | 8 | 0.04 | 165 | 14.97 | 244 | 603 | 3.75 / 385.88 | 2 | 7 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 29 | 15.01 | 398 | 173 | 0.17 / 379.36 | 2 | 2 |
2 | 10 | 1002.28 | 2 | 15.02 | 1628 | 49 | 0.22 / 379.40 | 2 | 2 |
3 | 7 | 1242.08 | 31 | 15.05 | 1877 | 876 | 1.10 / 380.28 | 2 | 3 |
4 | 13 | 1190.80 | 18 | 14.99 | 1828 | 493 | 1.59 / 380.77 | 2 | 3 |
5 | 13 | 1076.28 | 18 | 14.96 | 1674 | 451 | 2.04 / 381.22 | 2 | 3 |
6 | 13 | 368.84 | 18 | 15.03 | 758 | 205 | 2.25 / 381.43 | 2 | 2 |
7 | 13 | 56.76 | 18 | 15.04 | 331 | 90 | 2.34 / 381.52 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.02 | 244 | 605 | 2.94 / 382.12 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 30 | 15.00 | 395 | 178 | 0.18 / 376.68 | 2 | 2 |
2 | 3 | 980.68 | -1 | 15.32 | 0 | 0 | 0.00 / 376.68 | 2 | 2 |
3 | 7 | 1044.48 | 31 | 15.12 | 1619 | 759 | 0.94 / 377.44 | 2 | 3 |
4 | 13 | 1044.76 | 18 | 15.06 | 1624 | 440 | 1.38 / 377.88 | 2 | 2 |
5 | 13 | 925.28 | 18 | 15.02 | 1473 | 398 | 1.78 / 378.28 | 2 | 3 |
6 | 13 | 373.08 | 18 | 15.06 | 763 | 207 | 1.98 / 378.49 | 2 | 3 |
7 | 13 | 52.00 | 18 | 15.08 | 325 | 88 | 2.07 / 378.57 | 2 | 3 |
8 | 8 | 0.24 | 165 | 15.05 | 245 | 608 | 2.68 / 379.18 | 2 | 5 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 30 | 14.97 | 379 | 170 | 0.17 / 374.02 | 2 | 2 |
2 | 7 | 996.72 | 31 | 15.14 | 1563 | 734 | 0.90 / 374.75 | 2 | 3 |
3 | 13 | 996.12 | 18 | 15.07 | 1571 | 426 | 1.33 / 375.18 | 2 | 2 |
4 | 13 | 892.24 | 18 | 15.05 | 1433 | 388 | 1.72 / 375.56 | 2 | 3 |
5 | 13 | 478.64 | 18 | 15.06 | 903 | 245 | 1.96 / 375.81 | 2 | 2 |
6 | 13 | 39.56 | 18 | 15.09 | 307 | 83 | 2.05 / 375.89 | 2 | 5 |
7 | 8 | 0.12 | 165 | 15.06 | 246 | 611 | 2.66 / 376.50 | 2 | 9 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 30 | 14.94 | 396 | 177 | 0.18 / 370.82 | 2 | 2 |
2 | 7 | 1514.56 | 31 | 14.96 | 2222 | 1030 | 1.21 / 371.85 | 2 | 2 |
3 | 13 | 1412.92 | 18 | 14.92 | 2102 | 565 | 1.77 / 372.42 | 2 | 3 |
4 | 13 | 1008.72 | 18 | 14.92 | 1606 | 431 | 2.20 / 372.85 | 2 | 3 |
5 | 13 | 327.56 | 18 | 15.01 | 703 | 190 | 2.39 / 373.04 | 2 | 3 |
6 | 13 | 50.32 | 18 | 15.04 | 322 | 87 | 2.48 / 373.13 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.02 | 246 | 610 | 3.09 / 373.74 | 2 | 4 |
8 | 14 | 0.12 | 30 | 15.00 | 244 | 110 | 3.20 / 373.85 | 2 | 11 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 30 | 14.94 | 404 | 181 | 0.18 / 367.20 | 2 | 2 |
2 | 7 | 2004.48 | 31 | 14.82 | 2822 | 1296 | 1.48 / 368.50 | 2 | 2 |
3 | 13 | 1583.48 | 18 | 14.81 | 2318 | 618 | 2.10 / 369.12 | 2 | 3 |
4 | 13 | 1166.20 | 18 | 14.82 | 1800 | 480 | 2.58 / 369.60 | 2 | 3 |
5 | 13 | 724.40 | 18 | 14.87 | 1233 | 330 | 2.91 / 369.93 | 2 | 3 |
6 | 13 | 121.04 | 18 | 14.98 | 421 | 114 | 3.02 / 370.04 | 2 | 4 |
7 | 8 | 0.08 | 165 | 14.98 | 245 | 606 | 3.62 / 370.65 | 2 | 4 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 30 | 14.96 | 393 | 176 | 0.18 / 363.59 | 2 | 2 |
2 | 7 | 2005.44 | 32 | 14.83 | 2820 | 1338 | 1.51 / 364.92 | 2 | 2 |
3 | 13 | 1618.48 | 18 | 14.80 | 2371 | 632 | 2.15 / 365.56 | 2 | 3 |
4 | 13 | 1082.44 | 18 | 14.83 | 1691 | 451 | 2.60 / 366.01 | 2 | 3 |
5 | 13 | 638.72 | 18 | 14.88 | 1130 | 303 | 2.90 / 366.31 | 2 | 3 |
6 | 13 | 91.08 | 18 | 14.98 | 383 | 103 | 3.00 / 366.41 | 2 | 3 |
7 | 8 | 0.04 | 165 | 14.98 | 246 | 608 | 3.61 / 367.02 | 2 | 10 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 29 | 14.94 | 388 | 168 | 0.17 / 359.75 | 2 | 2 |
2 | 3 | 1022.16 | 1 | 15.07 | 1695 | 26 | 0.19 / 359.78 | 2 | 2 |
3 | 7 | 2002.96 | 32 | 14.82 | 2822 | 1338 | 1.53 / 361.11 | 2 | 2 |
4 | 13 | 1739.92 | 18 | 14.79 | 2515 | 670 | 2.20 / 361.78 | 2 | 3 |
5 | 13 | 1316.84 | 18 | 14.79 | 1991 | 530 | 2.73 / 362.31 | 2 | 3 |
6 | 13 | 590.56 | 18 | 14.90 | 1053 | 282 | 3.01 / 362.60 | 2 | 3 |
7 | 13 | 82.00 | 18 | 14.99 | 365 | 98 | 3.11 / 362.69 | 2 | 2 |
8 | 8 | 0.20 | 165 | 14.99 | 245 | 606 | 3.72 / 363.30 | 2 | 4 |
9 | 14 | 0.20 | 30 | 14.97 | 243 | 109 | 3.83 / 363.41 | 3 | 8 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 30 | 14.96 | 393 | 176 | 0.18 / 356.18 | 2 | 2 |
2 | 3 | 974.80 | -1 | 15.35 | 0 | 0 | 0.00 / 356.18 | 2 | 2 |
3 | 7 | 2007.68 | 31 | 14.82 | 2835 | 1302 | 1.48 / 357.49 | 2 | 3 |
4 | 13 | 1604.44 | 18 | 14.80 | 2349 | 626 | 2.10 / 358.11 | 2 | 2 |
5 | 13 | 1080.96 | 18 | 14.83 | 1693 | 452 | 2.56 / 358.56 | 2 | 3 |
6 | 13 | 657.76 | 18 | 14.89 | 1141 | 306 | 2.86 / 358.87 | 2 | 3 |
7 | 13 | 99.72 | 18 | 14.98 | 391 | 105 | 2.97 / 358.97 | 2 | 2 |
8 | 8 | 0.04 | 165 | 14.98 | 246 | 608 | 3.58 / 359.58 | 2 | 14 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 30 | 14.97 | 393 | 176 | 0.18 / 352.87 | 2 | 2 |
2 | 3 | 1016.32 | 1 | 15.11 | 1672 | 25 | 0.20 / 352.90 | 2 | 2 |
3 | 7 | 1618.32 | 31 | 14.94 | 2345 | 1086 | 1.29 / 353.98 | 2 | 2 |
4 | 13 | 1503.36 | 18 | 14.90 | 2228 | 598 | 1.89 / 354.58 | 2 | 3 |
5 | 13 | 1065.84 | 18 | 14.90 | 1675 | 449 | 2.33 / 355.03 | 2 | 3 |
6 | 13 | 374.32 | 18 | 14.99 | 768 | 207 | 2.54 / 355.24 | 2 | 3 |
7 | 13 | 57.72 | 18 | 15.03 | 333 | 90 | 2.63 / 355.33 | 2 | 4 |
8 | 13 | 15.20 | 18 | 15.03 | 272 | 74 | 2.71 / 355.40 | 2 | 5 |
9 | 8 | 0.12 | 165 | 15.01 | 244 | 604 | 3.31 / 356.01 | 2 | 3 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 30 | 14.95 | 395 | 177 | 0.18 / 349.28 | 2 | 2 |
2 | 7 | 2004.24 | 31 | 14.84 | 2823 | 1299 | 1.48 / 350.58 | 2 | 2 |
3 | 13 | 1613.52 | 18 | 14.80 | 2356 | 628 | 2.10 / 351.21 | 2 | 3 |
4 | 13 | 1187.08 | 18 | 14.82 | 1817 | 485 | 2.59 / 351.69 | 2 | 3 |
5 | 13 | 612.76 | 18 | 14.90 | 1088 | 292 | 2.88 / 351.98 | 2 | 3 |
6 | 13 | 87.76 | 18 | 15.00 | 379 | 102 | 2.98 / 352.09 | 2 | 2 |
7 | 8 | 0.20 | 165 | 14.99 | 247 | 611 | 3.59 / 352.70 | 2 | 8 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 29 | 14.94 | 388 | 168 | 0.17 / 345.69 | 2 | 2 |
2 | 3 | 1025.80 | 1 | 15.09 | 1690 | 26 | 0.19 / 345.71 | 2 | 3 |
3 | 7 | 2002.68 | 31 | 14.83 | 2818 | 1296 | 1.49 / 347.01 | 2 | 3 |
4 | 13 | 1581.20 | 18 | 14.82 | 2312 | 617 | 2.11 / 347.62 | 2 | 3 |
5 | 13 | 1166.92 | 18 | 14.83 | 1793 | 479 | 2.58 / 348.10 | 2 | 3 |
6 | 13 | 589.12 | 18 | 14.90 | 1060 | 284 | 2.87 / 348.39 | 2 | 3 |
7 | 13 | 68.08 | 18 | 15.01 | 356 | 96 | 2.96 / 348.48 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.00 | 251 | 621 | 3.59 / 349.10 | 2 | 6 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 29 | 14.95 | 393 | 170 | 0.17 / 342.07 | 2 | 2 |
2 | 7 | 2009.52 | 32 | 14.84 | 2828 | 1343 | 1.51 / 343.42 | 2 | 2 |
3 | 13 | 1489.12 | 18 | 14.81 | 2199 | 586 | 2.10 / 344.00 | 2 | 3 |
4 | 13 | 1215.60 | 18 | 14.81 | 1859 | 496 | 2.60 / 344.50 | 2 | 3 |
5 | 13 | 632.64 | 18 | 14.89 | 1119 | 300 | 2.90 / 344.80 | 2 | 3 |
6 | 13 | 83.48 | 18 | 15.00 | 376 | 102 | 3.00 / 344.90 | 2 | 4 |
7 | 8 | -0.08 | 165 | 14.98 | 250 | 618 | 3.61 / 345.52 | 2 | 9 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 29 | 14.97 | 394 | 171 | 0.17 / 338.50 | 2 | 2 |
2 | 7 | 2004.20 | 31 | 14.84 | 2823 | 1299 | 1.47 / 339.80 | 2 | 3 |
3 | 13 | 1604.32 | 18 | 14.82 | 2355 | 628 | 2.10 / 340.43 | 2 | 3 |
4 | 13 | 1163.20 | 18 | 14.84 | 1797 | 480 | 2.58 / 340.91 | 2 | 3 |
5 | 13 | 589.32 | 18 | 14.93 | 1056 | 284 | 2.86 / 341.19 | 2 | 3 |
6 | 13 | 68.60 | 18 | 15.01 | 352 | 95 | 2.96 / 341.29 | 2 | 3 |
7 | 8 | 0.20 | 165 | 14.99 | 249 | 616 | 3.57 / 341.90 | 2 | 4 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 29 | 14.96 | 387 | 168 | 0.17 / 334.84 | 2 | 2 |
2 | 7 | 2008.04 | 31 | 14.85 | 2830 | 1303 | 1.47 / 336.14 | 2 | 2 |
3 | 13 | 1733.64 | 18 | 14.81 | 2505 | 668 | 2.14 / 336.81 | 2 | 2 |
4 | 13 | 1166.84 | 18 | 14.84 | 1800 | 481 | 2.62 / 337.29 | 2 | 3 |
5 | 13 | 724.64 | 18 | 14.89 | 1235 | 331 | 2.95 / 337.62 | 2 | 3 |
6 | 13 | 61.28 | 18 | 15.02 | 343 | 93 | 3.04 / 337.71 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.00 | 250 | 619 | 3.66 / 338.33 | 2 | 8 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 29 | 14.97 | 399 | 173 | 0.17 / 331.05 | 2 | 2 |
2 | 7 | 2008.96 | 31 | 14.83 | 2822 | 1297 | 1.47 / 332.35 | 2 | 2 |
3 | 13 | 1727.68 | 18 | 14.80 | 2502 | 667 | 2.14 / 333.01 | 2 | 3 |
4 | 13 | 1175.24 | 18 | 14.83 | 1813 | 484 | 2.62 / 333.50 | 2 | 2 |
5 | 13 | 754.20 | 18 | 14.88 | 1270 | 340 | 2.96 / 333.84 | 2 | 3 |
6 | 13 | 76.88 | 18 | 15.01 | 365 | 99 | 3.06 / 333.94 | 2 | 2 |
7 | 8 | 0.12 | 165 | 14.99 | 251 | 621 | 3.68 / 334.56 | 2 | 5 |
8 | 14 | 0.12 | 30 | 14.97 | 249 | 112 | 3.79 / 334.67 | 3 | 12 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 29 | 14.98 | 398 | 173 | 0.17 / 327.40 | 2 | 2 |
2 | 3 | 1017.92 | 1 | 15.10 | 1692 | 26 | 0.20 / 327.42 | 2 | 2 |
3 | 7 | 2003.20 | 31 | 14.86 | 2829 | 1303 | 1.50 / 328.73 | 2 | 2 |
4 | 13 | 1619.12 | 18 | 14.83 | 2366 | 632 | 2.13 / 329.36 | 2 | 3 |
5 | 13 | 1204.96 | 18 | 14.84 | 1843 | 492 | 2.63 / 329.85 | 2 | 3 |
6 | 13 | 634.60 | 18 | 14.91 | 1119 | 300 | 2.93 / 330.15 | 2 | 3 |
7 | 13 | 91.68 | 18 | 15.02 | 387 | 105 | 3.03 / 330.25 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.01 | 251 | 622 | 3.65 / 330.88 | 2 | 6 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 28 | 14.98 | 398 | 167 | 0.17 / 323.85 | 2 | 2 |
2 | 7 | 2011.80 | 31 | 14.83 | 2820 | 1296 | 1.46 / 325.15 | 2 | 3 |
3 | 13 | 1623.00 | 18 | 14.82 | 2369 | 632 | 2.10 / 325.78 | 2 | 3 |
4 | 13 | 1076.36 | 18 | 14.85 | 1690 | 452 | 2.55 / 326.23 | 2 | 3 |
5 | 13 | 511.12 | 18 | 14.93 | 959 | 258 | 2.80 / 326.49 | 2 | 3 |
6 | 13 | 105.36 | 18 | 15.00 | 405 | 109 | 2.91 / 326.60 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.00 | 253 | 626 | 3.54 / 327.22 | 2 | 9 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 28 | 14.98 | 396 | 166 | 0.17 / 320.14 | 2 | 2 |
2 | 7 | 2004.96 | 31 | 14.85 | 2822 | 1299 | 1.47 / 321.44 | 2 | 2 |
3 | 13 | 1589.68 | 18 | 14.83 | 2336 | 624 | 2.09 / 322.06 | 2 | 2 |
4 | 13 | 1057.72 | 18 | 14.86 | 1660 | 444 | 2.53 / 322.51 | 2 | 3 |
5 | 13 | 774.28 | 18 | 14.88 | 1299 | 348 | 2.88 / 322.85 | 2 | 3 |
6 | 13 | 66.92 | 18 | 15.02 | 352 | 95 | 2.98 / 322.95 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.00 | 251 | 621 | 3.60 / 323.57 | 2 | 7 |
8 | 14 | 0.04 | 30 | 14.99 | 251 | 113 | 3.71 / 323.68 | 2 | 7 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 28 | 14.96 | 393 | 165 | 0.16 / 316.51 | 2 | 2 |
2 | 7 | 2002.96 | 32 | 14.85 | 2813 | 1337 | 1.50 / 317.84 | 2 | 2 |
3 | 13 | 1716.04 | 18 | 14.82 | 2476 | 660 | 2.16 / 318.50 | 2 | 3 |
4 | 13 | 1137.36 | 18 | 14.86 | 1762 | 471 | 2.63 / 318.97 | 2 | 3 |
5 | 13 | 561.24 | 18 | 14.94 | 1025 | 276 | 2.91 / 319.25 | 2 | 3 |
6 | 13 | 53.12 | 18 | 15.03 | 338 | 91 | 3.00 / 319.34 | 2 | 3 |
7 | 8 | 0.28 | 165 | 15.01 | 255 | 632 | 3.63 / 319.97 | 2 | 5 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 29 | 14.98 | 393 | 171 | 0.17 / 312.94 | 2 | 2 |
2 | 7 | 2012.12 | 32 | 14.84 | 2835 | 1346 | 1.52 / 314.29 | 2 | 2 |
3 | 13 | 1605.16 | 18 | 14.82 | 2354 | 628 | 2.14 / 314.92 | 2 | 3 |
4 | 13 | 1067.68 | 18 | 14.85 | 1672 | 447 | 2.59 / 315.36 | 2 | 3 |
5 | 13 | 530.36 | 18 | 14.94 | 978 | 263 | 2.85 / 315.63 | 2 | 3 |
6 | 13 | 53.28 | 18 | 15.02 | 333 | 90 | 2.94 / 315.72 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.00 | 253 | 626 | 3.57 / 316.34 | 2 | 10 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 28 | 14.98 | 413 | 173 | 0.17 / 309.25 | 2 | 2 |
2 | 3 | 1033.72 | 1 | 15.09 | 1690 | 26 | 0.20 / 309.28 | 2 | 3 |
3 | 7 | 2002.88 | 31 | 14.85 | 2818 | 1297 | 1.50 / 310.57 | 2 | 2 |
4 | 13 | 1721.88 | 18 | 14.82 | 2502 | 667 | 2.16 / 311.24 | 2 | 2 |
5 | 13 | 1163.76 | 18 | 14.85 | 1793 | 479 | 2.64 / 311.72 | 2 | 3 |
6 | 13 | 729.00 | 18 | 14.89 | 1239 | 332 | 2.97 / 312.05 | 2 | 3 |
7 | 13 | 61.40 | 18 | 15.03 | 345 | 93 | 3.07 / 312.15 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.01 | 252 | 624 | 3.69 / 312.77 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 28 | 14.97 | 398 | 167 | 0.17 / 305.66 | 2 | 2 |
2 | 7 | 2008.80 | 31 | 14.86 | 2823 | 1300 | 1.47 / 306.96 | 2 | 2 |
3 | 13 | 1602.80 | 18 | 14.84 | 2354 | 629 | 2.10 / 307.58 | 2 | 3 |
4 | 13 | 1169.00 | 18 | 14.85 | 1798 | 481 | 2.58 / 308.07 | 2 | 3 |
5 | 13 | 600.20 | 18 | 14.94 | 1075 | 289 | 2.87 / 308.35 | 2 | 3 |
6 | 13 | 73.56 | 18 | 15.03 | 360 | 97 | 2.96 / 308.45 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.01 | 253 | 627 | 3.59 / 309.08 | 2 | 6 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.12 | 28 | 14.98 | 402 | 169 | 0.17 / 302.11 | 2 | 2 |
2 | 7 | 2002.96 | 31 | 14.85 | 2830 | 1303 | 1.47 / 303.41 | 2 | 3 |
3 | 13 | 1737.32 | 18 | 14.80 | 2499 | 666 | 2.14 / 304.08 | 2 | 2 |
4 | 13 | 1037.04 | 18 | 14.86 | 1632 | 437 | 2.57 / 304.51 | 2 | 3 |
5 | 13 | 499.36 | 18 | 14.94 | 941 | 253 | 2.83 / 304.77 | 2 | 3 |
6 | 13 | 45.52 | 18 | 15.03 | 326 | 88 | 2.91 / 304.85 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.01 | 256 | 634 | 3.55 / 305.49 | 2 | 6 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 28 | 14.98 | 401 | 168 | 0.17 / 298.50 | 2 | 2 |
2 | 7 | 2007.28 | 31 | 14.86 | 2819 | 1299 | 1.47 / 299.80 | 2 | 2 |
3 | 13 | 1602.84 | 18 | 14.84 | 2359 | 630 | 2.10 / 300.43 | 2 | 2 |
4 | 13 | 1187.00 | 18 | 14.85 | 1830 | 489 | 2.59 / 300.92 | 2 | 3 |
5 | 13 | 609.96 | 18 | 14.93 | 1088 | 292 | 2.88 / 301.21 | 2 | 3 |
6 | 13 | 79.16 | 18 | 15.03 | 372 | 101 | 2.98 / 301.31 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.02 | 253 | 627 | 3.61 / 301.94 | 2 | 8 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 28 | 14.97 | 403 | 169 | 0.17 / 294.89 | 2 | 2 |
2 | 7 | 2005.64 | 31 | 14.85 | 2817 | 1297 | 1.47 / 296.18 | 2 | 3 |
3 | 13 | 1741.28 | 18 | 14.80 | 2522 | 672 | 2.14 / 296.85 | 2 | 2 |
4 | 13 | 1146.80 | 18 | 14.84 | 1777 | 475 | 2.61 / 297.33 | 2 | 3 |
5 | 13 | 564.00 | 18 | 14.93 | 1029 | 277 | 2.89 / 297.61 | 2 | 3 |
6 | 13 | 58.36 | 18 | 15.04 | 344 | 93 | 2.98 / 297.70 | 2 | 3 |
7 | 8 | 0.28 | 165 | 15.01 | 256 | 634 | 3.62 / 298.33 | 2 | 10 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.92 | 28 | 14.97 | 398 | 167 | 0.17 / 291.31 | 2 | 2 |
2 | 7 | 2005.56 | 31 | 14.86 | 2818 | 1298 | 1.46 / 292.61 | 2 | 2 |
3 | 13 | 1733.00 | 18 | 14.81 | 2495 | 665 | 2.13 / 293.27 | 2 | 3 |
4 | 13 | 1156.24 | 18 | 14.85 | 1785 | 477 | 2.61 / 293.75 | 2 | 3 |
5 | 13 | 487.12 | 18 | 14.95 | 920 | 248 | 2.85 / 294.00 | 2 | 3 |
6 | 13 | 43.48 | 18 | 15.02 | 325 | 88 | 2.94 / 294.09 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.01 | 255 | 632 | 3.57 / 294.72 | 2 | 5 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.88 | 28 | 14.98 | 398 | 167 | 0.17 / 287.70 | 2 | 2 |
2 | 7 | 2005.20 | 31 | 14.85 | 2815 | 1296 | 1.46 / 289.00 | 2 | 2 |
3 | 13 | 1730.80 | 18 | 14.82 | 2509 | 669 | 2.13 / 289.66 | 2 | 2 |
4 | 13 | 1157.40 | 18 | 14.85 | 1790 | 478 | 2.61 / 290.14 | 2 | 3 |
5 | 13 | 568.64 | 18 | 14.94 | 1038 | 279 | 2.89 / 290.42 | 2 | 3 |
6 | 13 | 57.80 | 18 | 15.02 | 340 | 92 | 2.98 / 290.51 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.01 | 254 | 629 | 3.61 / 291.14 | 2 | 8 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.88 | 29 | 14.97 | 415 | 180 | 0.18 / 284.02 | 2 | 2 |
2 | 7 | 2004.20 | 31 | 14.85 | 2817 | 1297 | 1.48 / 285.31 | 2 | 2 |
3 | 13 | 1728.68 | 18 | 14.81 | 2489 | 664 | 2.14 / 285.98 | 2 | 2 |
4 | 13 | 1161.28 | 18 | 14.85 | 1793 | 479 | 2.62 / 286.46 | 2 | 3 |
5 | 13 | 716.32 | 18 | 14.90 | 1226 | 329 | 2.95 / 286.78 | 2 | 3 |
6 | 13 | 123.96 | 18 | 15.02 | 431 | 117 | 3.07 / 286.90 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.01 | 255 | 632 | 3.70 / 287.53 | 2 | 11 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 28 | 14.98 | 407 | 171 | 0.17 / 280.38 | 2 | 2 |
2 | 3 | 1026.76 | 1 | 15.08 | 1695 | 26 | 0.20 / 280.40 | 2 | 2 |
3 | 7 | 2004.80 | 31 | 14.85 | 2830 | 1303 | 1.50 / 281.70 | 2 | 2 |
4 | 13 | 1734.64 | 18 | 14.81 | 2511 | 669 | 2.17 / 282.37 | 2 | 3 |
5 | 13 | 1047.36 | 18 | 14.87 | 1647 | 441 | 2.61 / 282.81 | 2 | 3 |
6 | 13 | 622.16 | 18 | 14.93 | 1108 | 298 | 2.91 / 283.11 | 2 | 3 |
7 | 13 | 80.04 | 18 | 15.02 | 370 | 100 | 3.01 / 283.21 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.01 | 252 | 624 | 3.63 / 283.84 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 28 | 15.00 | 410 | 172 | 0.17 / 276.81 | 2 | 2 |
2 | 7 | 2004.68 | 31 | 14.87 | 2817 | 1299 | 1.47 / 278.11 | 2 | 2 |
3 | 13 | 1574.28 | 18 | 14.85 | 2309 | 617 | 2.09 / 278.73 | 2 | 3 |
4 | 13 | 1137.96 | 18 | 14.86 | 1761 | 471 | 2.56 / 279.20 | 2 | 3 |
5 | 13 | 565.80 | 18 | 14.96 | 1034 | 278 | 2.84 / 279.48 | 2 | 3 |
6 | 13 | 62.64 | 18 | 15.02 | 349 | 94 | 2.93 / 279.57 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.01 | 255 | 632 | 3.56 / 280.20 | 2 | 6 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.00 | 28 | 14.98 | 403 | 169 | 0.17 / 273.13 | 2 | 2 |
2 | 3 | 970.64 | -1 | 15.35 | 0 | 0 | 0.00 / 273.13 | 2 | 2 |
3 | 7 | 2007.56 | 32 | 14.87 | 2841 | 1352 | 1.52 / 274.48 | 2 | 2 |
4 | 13 | 1736.92 | 18 | 14.83 | 2524 | 674 | 2.19 / 275.15 | 2 | 3 |
5 | 13 | 1179.08 | 18 | 14.85 | 1819 | 486 | 2.68 / 275.64 | 2 | 3 |
6 | 13 | 571.24 | 18 | 14.94 | 1042 | 280 | 2.96 / 275.92 | 2 | 3 |
7 | 13 | 67.40 | 18 | 15.05 | 353 | 96 | 3.06 / 276.01 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.03 | 253 | 627 | 3.68 / 276.64 | 2 | 5 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 14.99 | 397 | 167 | 0.17 / 269.43 | 2 | 2 |
2 | 3 | 1017.04 | 1 | 15.14 | 1689 | 26 | 0.19 / 269.45 | 2 | 2 |
3 | 7 | 2009.52 | 31 | 14.86 | 2833 | 1305 | 1.50 / 270.76 | 2 | 2 |
4 | 13 | 1747.60 | 18 | 14.83 | 2533 | 676 | 2.17 / 271.43 | 2 | 3 |
5 | 13 | 1176.80 | 18 | 14.86 | 1816 | 486 | 2.66 / 271.92 | 2 | 3 |
6 | 13 | 602.72 | 18 | 14.94 | 1084 | 292 | 2.95 / 272.21 | 2 | 3 |
7 | 13 | 75.80 | 18 | 15.04 | 372 | 101 | 3.05 / 272.31 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.02 | 260 | 644 | 3.70 / 272.96 | 2 | 11 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 28 | 14.99 | 397 | 167 | 0.17 / 265.87 | 2 | 2 |
2 | 7 | 2006.32 | 31 | 14.87 | 2828 | 1304 | 1.47 / 267.17 | 2 | 2 |
3 | 13 | 1605.24 | 18 | 14.85 | 2356 | 630 | 2.10 / 267.80 | 2 | 3 |
4 | 13 | 1180.00 | 18 | 14.86 | 1813 | 485 | 2.58 / 268.29 | 2 | 3 |
5 | 13 | 473.84 | 18 | 14.97 | 901 | 243 | 2.83 / 268.53 | 2 | 3 |
6 | 13 | 86.08 | 18 | 15.04 | 376 | 102 | 2.93 / 268.63 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.03 | 254 | 630 | 3.56 / 269.26 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 29 | 15.01 | 391 | 170 | 0.17 / 262.24 | 2 | 2 |
2 | 7 | 2004.56 | 32 | 14.86 | 2805 | 1334 | 1.50 / 263.58 | 2 | 2 |
3 | 13 | 1599.56 | 18 | 14.84 | 2343 | 626 | 2.13 / 264.20 | 2 | 3 |
4 | 13 | 1170.16 | 18 | 14.85 | 1813 | 485 | 2.61 / 264.69 | 2 | 4 |
5 | 13 | 607.96 | 18 | 14.93 | 1087 | 292 | 2.91 / 264.98 | 2 | 3 |
6 | 13 | 71.60 | 18 | 15.03 | 359 | 97 | 3.00 / 265.07 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.02 | 253 | 627 | 3.63 / 265.70 | 2 | 5 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 29 | 14.99 | 410 | 178 | 0.18 / 258.63 | 2 | 2 |
2 | 7 | 2007.24 | 32 | 14.87 | 2826 | 1345 | 1.52 / 259.97 | 2 | 2 |
3 | 13 | 1594.24 | 18 | 14.86 | 2344 | 627 | 2.15 / 260.60 | 2 | 3 |
4 | 13 | 1142.20 | 18 | 14.87 | 1781 | 477 | 2.63 / 261.07 | 2 | 3 |
5 | 13 | 563.28 | 18 | 14.96 | 1023 | 275 | 2.90 / 261.35 | 2 | 3 |
6 | 13 | 68.32 | 18 | 15.04 | 353 | 96 | 3.00 / 261.45 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.04 | 252 | 625 | 3.62 / 262.07 | 2 | 9 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 29 | 15.02 | 392 | 171 | 0.17 / 255.10 | 2 | 2 |
2 | 7 | 2002.40 | 31 | 14.87 | 2807 | 1294 | 1.46 / 256.39 | 2 | 3 |
3 | 13 | 1617.60 | 18 | 14.84 | 2365 | 632 | 2.10 / 257.02 | 2 | 3 |
4 | 13 | 1053.80 | 18 | 14.89 | 1663 | 446 | 2.54 / 257.47 | 2 | 3 |
5 | 13 | 497.76 | 18 | 14.97 | 944 | 254 | 2.80 / 257.72 | 2 | 3 |
6 | 13 | 93.80 | 18 | 15.04 | 388 | 105 | 2.90 / 257.83 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.02 | 250 | 620 | 3.52 / 258.45 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 29 | 15.00 | 406 | 177 | 0.18 / 251.87 | 2 | 2 |
2 | 7 | 1527.64 | 31 | 15.00 | 2241 | 1042 | 1.22 / 252.91 | 2 | 3 |
3 | 13 | 1479.08 | 18 | 14.94 | 2196 | 591 | 1.81 / 253.50 | 2 | 3 |
4 | 13 | 1063.36 | 18 | 14.96 | 1673 | 451 | 2.26 / 253.95 | 2 | 4 |
5 | 13 | 479.56 | 18 | 15.02 | 912 | 247 | 2.51 / 254.20 | 2 | 3 |
6 | 13 | 82.84 | 18 | 15.07 | 375 | 102 | 2.61 / 254.30 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.06 | 252 | 626 | 3.23 / 254.93 | 2 | 9 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 29 | 15.00 | 403 | 175 | 0.18 / 248.31 | 2 | 2 |
2 | 7 | 2014.24 | 31 | 14.87 | 2840 | 1309 | 1.48 / 249.62 | 2 | 3 |
3 | 13 | 1626.24 | 18 | 14.85 | 2365 | 632 | 2.12 / 250.25 | 2 | 3 |
4 | 13 | 1081.92 | 18 | 14.88 | 1695 | 454 | 2.57 / 250.71 | 2 | 3 |
5 | 13 | 532.48 | 18 | 14.96 | 987 | 266 | 2.84 / 250.97 | 2 | 3 |
6 | 13 | 70.40 | 18 | 15.05 | 356 | 96 | 2.93 / 251.07 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.02 | 251 | 622 | 3.55 / 251.69 | 2 | 5 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 30 | 15.01 | 393 | 177 | 0.18 / 244.67 | 2 | 2 |
2 | 3 | 967.12 | -1 | 15.37 | 0 | 0 | 0.00 / 244.67 | 2 | 2 |
3 | 7 | 2010.00 | 32 | 14.88 | 2833 | 1349 | 1.53 / 246.02 | 2 | 2 |
4 | 13 | 1600.60 | 18 | 14.86 | 2348 | 628 | 2.15 / 246.65 | 2 | 3 |
5 | 13 | 1179.24 | 18 | 14.88 | 1812 | 485 | 2.64 / 247.13 | 2 | 3 |
6 | 13 | 597.04 | 18 | 14.95 | 1074 | 289 | 2.93 / 247.42 | 2 | 3 |
7 | 13 | 71.92 | 18 | 15.06 | 357 | 97 | 3.03 / 247.52 | 2 | 2 |
8 | 8 | 0.24 | 165 | 15.04 | 250 | 620 | 3.65 / 248.14 | 2 | 8 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 30 | 15.01 | 396 | 178 | 0.18 / 240.99 | 2 | 2 |
2 | 7 | 2006.28 | 31 | 14.89 | 2830 | 1306 | 1.48 / 242.29 | 2 | 2 |
3 | 13 | 1733.20 | 18 | 14.85 | 2504 | 669 | 2.15 / 242.96 | 2 | 3 |
4 | 13 | 1164.84 | 18 | 14.89 | 1807 | 484 | 2.64 / 243.45 | 2 | 3 |
5 | 13 | 717.52 | 18 | 14.94 | 1227 | 330 | 2.97 / 243.78 | 2 | 3 |
6 | 13 | 73.52 | 18 | 15.06 | 360 | 98 | 3.07 / 243.87 | 2 | 2 |
7 | 8 | 0.52 | 165 | 15.04 | 249 | 618 | 3.68 / 244.49 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 29 | 15.01 | 393 | 171 | 0.17 / 237.34 | 2 | 2 |
2 | 10 | 1006.36 | 2 | 15.07 | 1632 | 49 | 0.22 / 237.39 | 2 | 2 |
3 | 3 | 979.48 | -1 | 15.37 | 0 | 0 | 0.05 / 237.39 | 2 | 2 |
4 | 7 | 2005.00 | 31 | 14.89 | 2826 | 1304 | 1.52 / 238.69 | 2 | 2 |
5 | 13 | 1603.96 | 18 | 14.84 | 2348 | 627 | 2.15 / 239.32 | 2 | 3 |
6 | 13 | 1169.88 | 18 | 14.87 | 1805 | 483 | 2.64 / 239.80 | 2 | 3 |
7 | 13 | 591.08 | 18 | 14.95 | 1066 | 287 | 2.92 / 240.09 | 2 | 3 |
8 | 13 | 79.84 | 18 | 15.06 | 367 | 99 | 3.02 / 240.19 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.04 | 249 | 618 | 3.64 / 240.81 | 2 | 6 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 29 | 15.01 | 397 | 173 | 0.17 / 233.80 | 2 | 2 |
2 | 7 | 1924.28 | 31 | 14.89 | 2732 | 1261 | 1.43 / 235.06 | 2 | 2 |
3 | 13 | 1534.08 | 18 | 14.87 | 2281 | 611 | 2.04 / 235.67 | 2 | 3 |
4 | 13 | 1110.20 | 18 | 14.89 | 1737 | 466 | 2.51 / 236.13 | 2 | 3 |
5 | 13 | 673.84 | 18 | 14.95 | 1170 | 315 | 2.82 / 236.45 | 2 | 3 |
6 | 13 | 109.44 | 18 | 15.05 | 404 | 109 | 2.93 / 236.56 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.04 | 247 | 613 | 3.55 / 237.17 | 2 | 10 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 30 | 15.00 | 395 | 178 | 0.18 / 230.24 | 2 | 2 |
2 | 3 | 972.44 | -1 | 15.38 | 0 | 0 | 0.00 / 230.24 | 2 | 2 |
3 | 7 | 2007.44 | 31 | 14.89 | 2820 | 1302 | 1.48 / 231.54 | 2 | 3 |
4 | 13 | 1593.20 | 18 | 14.87 | 2337 | 626 | 2.10 / 232.16 | 2 | 2 |
5 | 13 | 1051.72 | 18 | 14.91 | 1658 | 445 | 2.55 / 232.61 | 2 | 3 |
6 | 13 | 620.84 | 18 | 14.96 | 1099 | 296 | 2.85 / 232.90 | 2 | 3 |
7 | 13 | 80.40 | 18 | 15.07 | 368 | 100 | 2.95 / 233.00 | 2 | 3 |
8 | 8 | 0.28 | 165 | 15.05 | 249 | 618 | 3.56 / 233.62 | 2 | 7 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 29 | 15.01 | 394 | 172 | 0.17 / 226.56 | 2 | 2 |
2 | 3 | 1021.52 | 1 | 15.12 | 1677 | 25 | 0.20 / 226.58 | 2 | 2 |
3 | 7 | 2006.60 | 32 | 14.89 | 2826 | 1347 | 1.54 / 227.93 | 2 | 2 |
4 | 13 | 1612.40 | 18 | 14.86 | 2362 | 632 | 2.18 / 228.56 | 2 | 3 |
5 | 13 | 1078.64 | 18 | 14.90 | 1698 | 455 | 2.63 / 229.02 | 2 | 3 |
6 | 13 | 653.52 | 18 | 14.96 | 1147 | 309 | 2.94 / 229.33 | 2 | 3 |
7 | 13 | 98.00 | 18 | 15.06 | 397 | 108 | 3.05 / 229.43 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.04 | 252 | 625 | 3.67 / 230.06 | 2 | 5 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 29 | 15.02 | 396 | 172 | 0.17 / 222.94 | 2 | 2 |
2 | 7 | 2005.68 | 31 | 14.90 | 2823 | 1304 | 1.48 / 224.24 | 2 | 2 |
3 | 13 | 1470.88 | 18 | 14.90 | 2195 | 589 | 2.07 / 224.83 | 2 | 3 |
4 | 13 | 1064.92 | 18 | 14.91 | 1678 | 450 | 2.52 / 225.28 | 2 | 3 |
5 | 13 | 510.92 | 18 | 14.99 | 966 | 261 | 2.78 / 225.54 | 2 | 3 |
6 | 13 | 99.04 | 18 | 15.06 | 399 | 108 | 2.88 / 225.65 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.04 | 251 | 623 | 3.51 / 226.27 | 2 | 4 |
8 | 14 | 0.12 | 30 | 15.03 | 247 | 111 | 3.62 / 226.39 | 2 | 11 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 29 | 15.00 | 396 | 172 | 0.17 / 219.34 | 2 | 2 |
2 | 7 | 2004.28 | 31 | 14.90 | 2832 | 1308 | 1.48 / 220.65 | 2 | 2 |
3 | 13 | 1593.32 | 18 | 14.87 | 2342 | 627 | 2.11 / 221.27 | 2 | 3 |
4 | 13 | 1154.20 | 18 | 14.89 | 1783 | 478 | 2.59 / 221.75 | 2 | 3 |
5 | 13 | 596.08 | 18 | 14.96 | 1075 | 289 | 2.87 / 222.04 | 2 | 3 |
6 | 13 | 71.72 | 18 | 15.07 | 359 | 97 | 2.97 / 222.14 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.05 | 253 | 628 | 3.60 / 222.77 | 2 | 8 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 29 | 15.02 | 390 | 170 | 0.17 / 215.66 | 2 | 2 |
2 | 7 | 2007.28 | 32 | 14.89 | 2826 | 1347 | 1.52 / 217.00 | 2 | 2 |
3 | 13 | 1594.20 | 18 | 14.89 | 2341 | 627 | 2.14 / 217.63 | 2 | 3 |
4 | 13 | 1045.44 | 18 | 14.92 | 1648 | 443 | 2.59 / 218.07 | 2 | 3 |
5 | 13 | 623.52 | 18 | 14.97 | 1106 | 298 | 2.88 / 218.37 | 2 | 3 |
6 | 13 | 86.24 | 18 | 15.05 | 376 | 102 | 2.99 / 218.47 | 2 | 2 |
7 | 13 | 21.04 | 18 | 15.07 | 284 | 77 | 3.06 / 218.55 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.05 | 249 | 618 | 3.68 / 219.17 | 2 | 11 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 29 | 15.02 | 392 | 171 | 0.17 / 212.00 | 2 | 2 |
2 | 7 | 2003.80 | 31 | 14.91 | 2817 | 1302 | 1.47 / 213.30 | 2 | 3 |
3 | 13 | 1598.72 | 18 | 14.88 | 2348 | 629 | 2.10 / 213.93 | 2 | 3 |
4 | 13 | 1153.96 | 18 | 14.91 | 1792 | 481 | 2.58 / 214.41 | 2 | 3 |
5 | 13 | 574.00 | 18 | 15.00 | 1046 | 282 | 2.87 / 214.69 | 2 | 3 |
6 | 13 | 76.88 | 18 | 15.08 | 362 | 98 | 2.96 / 214.79 | 2 | 2 |
7 | 13 | 19.84 | 18 | 15.09 | 283 | 77 | 3.04 / 214.87 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.06 | 249 | 619 | 3.66 / 215.49 | 2 | 7 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 29 | 15.03 | 393 | 171 | 0.17 / 208.33 | 2 | 2 |
2 | 7 | 2003.56 | 31 | 14.91 | 2827 | 1307 | 1.48 / 209.64 | 2 | 2 |
3 | 13 | 1604.04 | 18 | 14.88 | 2346 | 628 | 2.11 / 210.26 | 2 | 3 |
4 | 13 | 1174.64 | 18 | 14.91 | 1815 | 487 | 2.59 / 210.75 | 2 | 3 |
5 | 13 | 593.28 | 18 | 14.99 | 1068 | 288 | 2.88 / 211.04 | 2 | 3 |
6 | 13 | 73.72 | 18 | 15.08 | 357 | 97 | 2.98 / 211.14 | 2 | 2 |
7 | 13 | 17.96 | 18 | 15.09 | 279 | 76 | 3.05 / 211.21 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.06 | 247 | 614 | 3.67 / 211.83 | 2 | 7 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 29 | 15.03 | 395 | 172 | 0.17 / 204.63 | 2 | 2 |
2 | 7 | 2003.88 | 31 | 14.92 | 2822 | 1305 | 1.48 / 205.94 | 2 | 3 |
3 | 13 | 1733.24 | 18 | 14.88 | 2513 | 673 | 2.15 / 206.61 | 2 | 3 |
4 | 13 | 1143.00 | 18 | 14.91 | 1778 | 477 | 2.63 / 207.09 | 2 | 3 |
5 | 13 | 718.92 | 18 | 14.97 | 1230 | 331 | 2.96 / 207.42 | 2 | 3 |
6 | 13 | 121.60 | 18 | 15.09 | 427 | 116 | 3.08 / 207.54 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.07 | 250 | 622 | 3.70 / 208.16 | 2 | 4 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 29 | 15.04 | 394 | 172 | 0.17 / 201.03 | 2 | 2 |
2 | 7 | 2001.32 | 31 | 14.90 | 2817 | 1301 | 1.47 / 202.33 | 2 | 2 |
3 | 13 | 1577.28 | 18 | 14.89 | 2316 | 621 | 2.09 / 202.95 | 2 | 3 |
4 | 13 | 1151.88 | 18 | 14.92 | 1788 | 480 | 2.57 / 203.43 | 2 | 3 |
5 | 13 | 442.16 | 18 | 15.04 | 866 | 234 | 2.81 / 203.66 | 2 | 3 |
6 | 13 | 81.24 | 18 | 15.09 | 370 | 100 | 2.91 / 203.76 | 2 | 2 |
7 | 13 | 18.64 | 18 | 15.09 | 281 | 76 | 2.99 / 203.84 | 2 | 4 |
8 | 8 | 0.24 | 165 | 15.06 | 250 | 621 | 3.61 / 204.46 | 2 | 10 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 29 | 15.05 | 393 | 172 | 0.17 / 197.51 | 2 | 2 |
2 | 7 | 2004.24 | 31 | 14.90 | 2814 | 1300 | 1.47 / 198.81 | 2 | 2 |
3 | 13 | 1597.04 | 18 | 14.89 | 2354 | 631 | 2.10 / 199.44 | 2 | 3 |
4 | 13 | 1050.04 | 18 | 14.92 | 1662 | 446 | 2.55 / 199.89 | 2 | 3 |
5 | 13 | 498.88 | 18 | 15.01 | 943 | 255 | 2.80 / 200.15 | 2 | 3 |
6 | 13 | 52.92 | 18 | 15.10 | 330 | 90 | 2.89 / 200.24 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.08 | 249 | 620 | 3.51 / 200.86 | 2 | 7 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 29 | 15.03 | 394 | 172 | 0.17 / 193.92 | 2 | 2 |
2 | 7 | 2004.64 | 31 | 14.92 | 2825 | 1307 | 1.48 / 195.23 | 2 | 2 |
3 | 13 | 1592.60 | 18 | 14.90 | 2330 | 625 | 2.10 / 195.85 | 2 | 2 |
4 | 13 | 1152.16 | 18 | 14.93 | 1797 | 483 | 2.59 / 196.33 | 2 | 3 |
5 | 13 | 586.96 | 18 | 15.01 | 1062 | 287 | 2.87 / 196.62 | 2 | 3 |
6 | 13 | 72.56 | 18 | 15.10 | 359 | 98 | 2.97 / 196.72 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.08 | 251 | 625 | 3.60 / 197.34 | 2 | 7 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 29 | 15.06 | 400 | 175 | 0.17 / 190.32 | 2 | 2 |
2 | 7 | 2002.36 | 31 | 14.93 | 2821 | 1306 | 1.48 / 191.63 | 2 | 2 |
3 | 13 | 1601.12 | 18 | 14.90 | 2339 | 627 | 2.11 / 192.25 | 2 | 3 |
4 | 13 | 1175.20 | 18 | 14.92 | 1806 | 485 | 2.59 / 192.74 | 2 | 3 |
5 | 13 | 600.20 | 18 | 15.01 | 1074 | 290 | 2.88 / 193.03 | 2 | 3 |
6 | 13 | 75.08 | 18 | 15.11 | 361 | 98 | 2.98 / 193.13 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.07 | 250 | 622 | 3.60 / 193.75 | 2 | 4 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 29 | 15.06 | 402 | 176 | 0.18 / 186.74 | 2 | 2 |
2 | 7 | 2002.80 | 31 | 14.93 | 2828 | 1309 | 1.48 / 188.05 | 2 | 3 |
3 | 13 | 1594.96 | 18 | 14.91 | 2335 | 627 | 2.11 / 188.68 | 2 | 2 |
4 | 13 | 1048.44 | 18 | 14.95 | 1664 | 448 | 2.56 / 189.13 | 2 | 3 |
5 | 13 | 629.20 | 18 | 14.99 | 1115 | 301 | 2.86 / 189.43 | 2 | 3 |
6 | 13 | 85.16 | 18 | 15.11 | 373 | 101 | 2.96 / 189.53 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.09 | 247 | 615 | 3.58 / 190.14 | 2 | 6 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 28 | 15.05 | 402 | 169 | 0.17 / 183.14 | 2 | 2 |
2 | 7 | 2003.12 | 31 | 14.92 | 2833 | 1310 | 1.48 / 184.45 | 2 | 2 |
3 | 13 | 1598.64 | 18 | 14.90 | 2353 | 631 | 2.11 / 185.08 | 2 | 2 |
4 | 13 | 1167.64 | 18 | 14.93 | 1811 | 487 | 2.60 / 185.57 | 2 | 4 |
5 | 13 | 584.32 | 18 | 15.01 | 1059 | 286 | 2.88 / 185.86 | 2 | 3 |
6 | 13 | 76.72 | 18 | 15.11 | 362 | 98 | 2.98 / 185.95 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.09 | 247 | 615 | 3.60 / 186.57 | 2 | 7 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 28 | 15.06 | 402 | 170 | 0.17 / 179.45 | 2 | 2 |
2 | 3 | 1018.48 | 1 | 15.16 | 1693 | 26 | 0.20 / 179.47 | 2 | 2 |
3 | 7 | 2005.80 | 31 | 14.93 | 2828 | 1309 | 1.50 / 180.78 | 2 | 2 |
4 | 13 | 1716.28 | 18 | 14.90 | 2490 | 668 | 2.17 / 181.45 | 2 | 2 |
5 | 13 | 1120.08 | 18 | 14.94 | 1749 | 470 | 2.64 / 181.92 | 2 | 4 |
6 | 13 | 686.44 | 18 | 14.99 | 1191 | 321 | 2.96 / 182.24 | 2 | 3 |
7 | 13 | 112.48 | 18 | 15.11 | 413 | 112 | 3.08 / 182.35 | 2 | 2 |
8 | 8 | -0.04 | 165 | 15.10 | 248 | 618 | 3.69 / 182.97 | 2 | 7 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 29 | 15.06 | 398 | 174 | 0.17 / 175.94 | 2 | 2 |
2 | 7 | 2003.68 | 31 | 14.93 | 2813 | 1302 | 1.48 / 177.25 | 2 | 2 |
3 | 13 | 1579.32 | 18 | 14.90 | 2321 | 622 | 2.10 / 177.87 | 2 | 2 |
4 | 13 | 1029.88 | 18 | 14.95 | 1629 | 438 | 2.54 / 178.31 | 2 | 3 |
5 | 13 | 475.32 | 18 | 15.05 | 911 | 247 | 2.78 / 178.55 | 2 | 3 |
6 | 13 | 99.32 | 18 | 15.11 | 391 | 106 | 2.89 / 178.66 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.10 | 248 | 618 | 3.51 / 179.28 | 2 | 6 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 28 | 15.07 | 409 | 173 | 0.17 / 172.27 | 2 | 2 |
2 | 3 | 1020.88 | 1 | 15.17 | 1673 | 25 | 0.20 / 172.30 | 2 | 3 |
3 | 7 | 2003.72 | 31 | 14.92 | 2817 | 1303 | 1.50 / 173.60 | 2 | 2 |
4 | 13 | 1602.40 | 18 | 14.91 | 2354 | 632 | 2.13 / 174.23 | 2 | 3 |
5 | 13 | 1051.08 | 18 | 14.95 | 1659 | 446 | 2.58 / 174.68 | 2 | 3 |
6 | 13 | 499.48 | 18 | 15.04 | 943 | 255 | 2.83 / 174.94 | 2 | 3 |
7 | 13 | 96.76 | 18 | 15.10 | 389 | 106 | 2.94 / 175.04 | 2 | 2 |
8 | 8 | 0.20 | 165 | 15.09 | 248 | 617 | 3.56 / 175.66 | 2 | 7 |
9 | 14 | 0.20 | 30 | 15.06 | 247 | 112 | 3.67 / 175.77 | 2 | 6 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 28 | 15.07 | 400 | 169 | 0.17 / 168.67 | 2 | 2 |
2 | 7 | 2003.88 | 31 | 14.93 | 2819 | 1305 | 1.47 / 169.97 | 2 | 2 |
3 | 13 | 1603.04 | 18 | 14.91 | 2358 | 633 | 2.11 / 170.60 | 2 | 3 |
4 | 13 | 1083.12 | 18 | 14.94 | 1701 | 457 | 2.56 / 171.06 | 2 | 3 |
5 | 13 | 654.88 | 18 | 15.01 | 1150 | 311 | 2.87 / 171.37 | 2 | 3 |
6 | 13 | 96.28 | 18 | 15.11 | 390 | 106 | 2.98 / 171.48 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.10 | 250 | 623 | 3.60 / 172.10 | 2 | 5 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 28 | 15.07 | 401 | 169 | 0.17 / 165.07 | 2 | 2 |
2 | 7 | 2003.40 | 31 | 14.93 | 2825 | 1307 | 1.48 / 166.38 | 2 | 2 |
3 | 13 | 1594.88 | 18 | 14.92 | 2335 | 627 | 2.10 / 167.00 | 2 | 2 |
4 | 13 | 1157.84 | 18 | 14.94 | 1799 | 484 | 2.59 / 167.49 | 2 | 2 |
5 | 13 | 576.16 | 18 | 15.04 | 1051 | 285 | 2.87 / 167.77 | 2 | 3 |
6 | 13 | 76.20 | 18 | 15.13 | 364 | 99 | 2.97 / 167.87 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.11 | 251 | 626 | 3.60 / 168.50 | 2 | 4 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 15.08 | 395 | 167 | 0.17 / 161.42 | 2 | 2 |
2 | 7 | 2004.76 | 32 | 14.93 | 2822 | 1348 | 1.52 / 162.77 | 2 | 2 |
3 | 13 | 1594.28 | 18 | 14.92 | 2336 | 627 | 2.14 / 163.40 | 2 | 2 |
4 | 13 | 1164.48 | 18 | 14.94 | 1810 | 487 | 2.63 / 163.89 | 2 | 2 |
5 | 13 | 584.04 | 18 | 15.04 | 1055 | 286 | 2.91 / 164.17 | 2 | 3 |
6 | 13 | 69.44 | 18 | 15.12 | 356 | 97 | 3.01 / 164.27 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.11 | 253 | 631 | 3.64 / 164.90 | 2 | 8 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.88 | 28 | 15.10 | 403 | 170 | 0.17 / 157.75 | 2 | 2 |
2 | 7 | 2008.48 | 31 | 14.93 | 2826 | 1308 | 1.48 / 159.06 | 2 | 2 |
3 | 13 | 1607.84 | 18 | 14.93 | 2364 | 635 | 2.11 / 159.70 | 2 | 2 |
4 | 13 | 1055.20 | 18 | 14.97 | 1664 | 448 | 2.56 / 160.15 | 2 | 2 |
5 | 13 | 514.24 | 18 | 15.06 | 969 | 263 | 2.82 / 160.41 | 2 | 3 |
6 | 13 | 97.12 | 18 | 15.13 | 392 | 107 | 2.93 / 160.52 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.12 | 252 | 629 | 3.56 / 161.14 | 2 | 9 |
8 | 14 | 0.20 | 30 | 15.11 | 251 | 114 | 3.67 / 161.26 | 2 | 11 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 28 | 15.09 | 400 | 169 | 0.17 / 154.14 | 2 | 2 |
2 | 7 | 2003.60 | 31 | 14.95 | 2827 | 1310 | 1.48 / 155.45 | 2 | 2 |
3 | 13 | 1585.60 | 18 | 14.93 | 2344 | 630 | 2.11 / 156.08 | 2 | 2 |
4 | 13 | 1148.16 | 18 | 14.96 | 1783 | 480 | 2.59 / 156.56 | 2 | 2 |
5 | 13 | 578.28 | 18 | 15.04 | 1054 | 285 | 2.87 / 156.85 | 2 | 3 |
6 | 13 | 68.24 | 18 | 15.14 | 358 | 98 | 2.97 / 156.95 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.13 | 255 | 637 | 3.61 / 157.58 | 2 | 5 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 28 | 15.08 | 403 | 170 | 0.17 / 150.57 | 2 | 2 |
2 | 7 | 2006.32 | 31 | 14.95 | 2833 | 1313 | 1.48 / 151.88 | 2 | 2 |
3 | 13 | 1593.12 | 18 | 14.92 | 2341 | 629 | 2.11 / 152.51 | 2 | 2 |
4 | 13 | 1022.28 | 18 | 14.97 | 1622 | 437 | 2.55 / 152.95 | 2 | 2 |
5 | 13 | 596.84 | 18 | 15.03 | 1080 | 292 | 2.84 / 153.24 | 2 | 3 |
6 | 13 | 68.00 | 18 | 15.13 | 358 | 97 | 2.94 / 153.34 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.12 | 255 | 636 | 3.57 / 153.98 | 2 | 6 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 28 | 15.10 | 406 | 172 | 0.17 / 146.85 | 2 | 2 |
2 | 7 | 2003.12 | 31 | 14.94 | 2823 | 1307 | 1.48 / 148.16 | 2 | 2 |
3 | 13 | 1592.52 | 18 | 14.92 | 2335 | 627 | 2.11 / 148.79 | 2 | 2 |
4 | 13 | 1149.56 | 18 | 14.95 | 1788 | 481 | 2.59 / 149.27 | 2 | 2 |
5 | 13 | 578.76 | 18 | 15.05 | 1056 | 286 | 2.87 / 149.55 | 2 | 3 |
6 | 13 | 64.16 | 18 | 15.14 | 351 | 96 | 2.97 / 149.65 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.12 | 255 | 636 | 3.61 / 150.29 | 2 | 6 |
8 | 14 | 0.08 | 30 | 15.10 | 254 | 115 | 3.72 / 150.40 | 2 | 7 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 28 | 15.09 | 397 | 168 | 0.17 / 143.17 | 2 | 2 |
2 | 7 | 2005.64 | 31 | 14.96 | 2828 | 1312 | 1.48 / 144.48 | 2 | 2 |
3 | 13 | 1595.28 | 18 | 14.93 | 2346 | 630 | 2.11 / 145.12 | 2 | 2 |
4 | 13 | 1047.32 | 18 | 14.98 | 1655 | 446 | 2.56 / 145.56 | 2 | 2 |
5 | 13 | 508.24 | 18 | 15.07 | 958 | 260 | 2.82 / 145.82 | 2 | 3 |
6 | 13 | 96.84 | 18 | 15.14 | 396 | 108 | 2.92 / 145.93 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.13 | 255 | 637 | 3.56 / 146.57 | 2 | 6 |
8 | 14 | 0.16 | 30 | 15.12 | 252 | 114 | 3.67 / 146.68 | 2 | 8 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 27 | 15.10 | 400 | 163 | 0.16 / 139.64 | 2 | 2 |
2 | 7 | 2003.80 | 31 | 14.94 | 2828 | 1310 | 1.47 / 140.95 | 2 | 2 |
3 | 13 | 1597.88 | 18 | 14.92 | 2352 | 632 | 2.10 / 141.58 | 2 | 2 |
4 | 13 | 1051.24 | 18 | 14.97 | 1658 | 447 | 2.55 / 142.02 | 2 | 2 |
5 | 13 | 509.88 | 18 | 15.06 | 958 | 260 | 2.81 / 142.28 | 2 | 3 |
6 | 13 | 59.40 | 18 | 15.14 | 341 | 93 | 2.90 / 142.38 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.13 | 252 | 629 | 3.53 / 143.01 | 2 | 5 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 28 | 15.11 | 388 | 164 | 0.16 / 136.04 | 2 | 2 |
2 | 3 | 961.44 | -1 | 15.44 | 0 | 0 | 0.00 / 136.04 | 2 | 2 |
3 | 7 | 2002.00 | 31 | 14.95 | 2824 | 1309 | 1.47 / 137.35 | 2 | 2 |
4 | 13 | 1606.32 | 18 | 14.93 | 2356 | 633 | 2.11 / 137.98 | 2 | 2 |
5 | 13 | 1161.68 | 18 | 14.97 | 1808 | 487 | 2.59 / 138.47 | 2 | 2 |
6 | 13 | 581.20 | 18 | 15.06 | 1052 | 285 | 2.88 / 138.75 | 2 | 3 |
7 | 13 | 74.72 | 18 | 15.15 | 360 | 98 | 2.98 / 138.85 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.13 | 249 | 622 | 3.60 / 139.47 | 2 | 7 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 28 | 15.11 | 404 | 171 | 0.17 / 132.44 | 2 | 2 |
2 | 7 | 2003.84 | 31 | 14.97 | 2832 | 1314 | 1.49 / 133.75 | 2 | 2 |
3 | 13 | 1589.80 | 18 | 14.96 | 2348 | 632 | 2.12 / 134.39 | 2 | 2 |
4 | 13 | 1156.56 | 18 | 14.97 | 1791 | 483 | 2.60 / 134.87 | 2 | 2 |
5 | 13 | 579.08 | 18 | 15.06 | 1058 | 287 | 2.89 / 135.15 | 2 | 3 |
6 | 13 | 78.92 | 18 | 15.16 | 367 | 100 | 2.99 / 135.25 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.14 | 248 | 620 | 3.61 / 135.87 | 2 | 11 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 28 | 15.10 | 404 | 171 | 0.17 / 128.87 | 2 | 2 |
2 | 7 | 2003.64 | 31 | 14.96 | 2827 | 1311 | 1.48 / 130.18 | 2 | 2 |
3 | 13 | 1596.36 | 18 | 14.95 | 2339 | 629 | 2.11 / 130.81 | 2 | 2 |
4 | 13 | 1035.28 | 18 | 14.99 | 1635 | 441 | 2.55 / 131.25 | 2 | 2 |
5 | 13 | 606.24 | 18 | 15.05 | 1083 | 293 | 2.85 / 131.55 | 2 | 3 |
6 | 13 | 73.72 | 18 | 15.15 | 360 | 98 | 2.94 / 131.65 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.14 | 249 | 622 | 3.57 / 132.27 | 2 | 7 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 28 | 15.12 | 396 | 168 | 0.17 / 125.33 | 2 | 2 |
2 | 7 | 2007.84 | 31 | 14.95 | 2836 | 1314 | 1.48 / 126.65 | 2 | 2 |
3 | 13 | 1597.00 | 18 | 14.94 | 2340 | 629 | 2.11 / 127.28 | 2 | 2 |
4 | 13 | 1041.24 | 18 | 14.99 | 1647 | 444 | 2.56 / 127.72 | 2 | 2 |
5 | 13 | 485.80 | 18 | 15.08 | 925 | 251 | 2.81 / 127.97 | 2 | 3 |
6 | 13 | 92.44 | 18 | 15.15 | 386 | 105 | 2.91 / 128.08 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.14 | 250 | 625 | 3.54 / 128.70 | 2 | 7 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 28 | 15.14 | 397 | 168 | 0.17 / 121.75 | 2 | 2 |
2 | 7 | 2002.04 | 31 | 14.97 | 2822 | 1310 | 1.48 / 123.06 | 2 | 2 |
3 | 13 | 1571.28 | 18 | 14.97 | 2322 | 626 | 2.10 / 123.68 | 2 | 2 |
4 | 13 | 1147.96 | 18 | 14.99 | 1781 | 481 | 2.58 / 124.16 | 2 | 2 |
5 | 13 | 563.40 | 18 | 15.08 | 1028 | 279 | 2.86 / 124.44 | 2 | 3 |
6 | 13 | 70.40 | 18 | 15.17 | 353 | 96 | 2.96 / 124.54 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.15 | 250 | 625 | 3.58 / 125.17 | 2 | 4 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 29 | 15.13 | 388 | 170 | 0.17 / 118.23 | 2 | 2 |
2 | 7 | 2002.00 | 31 | 14.98 | 2818 | 1309 | 1.48 / 119.54 | 2 | 2 |
3 | 13 | 1577.44 | 18 | 14.97 | 2311 | 623 | 2.10 / 120.16 | 2 | 2 |
4 | 13 | 1031.84 | 18 | 15.00 | 1644 | 444 | 2.55 / 120.60 | 2 | 2 |
5 | 13 | 475.48 | 18 | 15.10 | 917 | 249 | 2.79 / 120.85 | 2 | 3 |
6 | 13 | 82.56 | 18 | 15.17 | 373 | 102 | 2.90 / 120.96 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.15 | 250 | 625 | 3.52 / 121.58 | 2 | 5 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 29 | 15.13 | 399 | 175 | 0.18 / 114.55 | 2 | 2 |
2 | 7 | 2002.84 | 31 | 14.98 | 2825 | 1312 | 1.49 / 115.87 | 2 | 2 |
3 | 13 | 1591.36 | 18 | 14.97 | 2342 | 631 | 2.12 / 116.50 | 2 | 2 |
4 | 13 | 1029.68 | 18 | 15.02 | 1631 | 441 | 2.56 / 116.94 | 2 | 2 |
5 | 13 | 591.80 | 18 | 15.08 | 1076 | 292 | 2.85 / 117.23 | 2 | 3 |
6 | 13 | 70.28 | 18 | 15.18 | 355 | 97 | 2.95 / 117.33 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.15 | 248 | 620 | 3.57 / 117.95 | 2 | 7 |
8 | 14 | 0.20 | 30 | 15.14 | 248 | 113 | 3.68 / 118.06 | 3 | 7 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 29 | 15.12 | 396 | 174 | 0.17 / 111.10 | 2 | 2 |
2 | 7 | 2004.28 | 31 | 14.97 | 2817 | 1307 | 1.48 / 112.41 | 2 | 2 |
3 | 13 | 1468.04 | 18 | 14.97 | 2182 | 588 | 2.07 / 113.00 | 2 | 2 |
4 | 13 | 1061.40 | 18 | 15.01 | 1673 | 452 | 2.52 / 113.45 | 2 | 2 |
5 | 13 | 375.56 | 18 | 15.14 | 779 | 212 | 2.73 / 113.66 | 2 | 3 |
6 | 13 | 60.00 | 18 | 15.18 | 343 | 94 | 2.83 / 113.75 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.16 | 250 | 625 | 3.45 / 114.38 | 2 | 6 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 28 | 15.13 | 395 | 167 | 0.17 / 107.57 | 2 | 2 |
2 | 3 | 1022.84 | 1 | 15.20 | 1695 | 26 | 0.19 / 107.59 | 2 | 2 |
3 | 7 | 2009.08 | 31 | 14.97 | 2834 | 1315 | 1.51 / 108.91 | 2 | 2 |
4 | 13 | 1459.80 | 18 | 14.98 | 2167 | 584 | 2.09 / 109.49 | 2 | 2 |
5 | 13 | 1068.92 | 18 | 15.01 | 1684 | 455 | 2.55 / 109.95 | 2 | 2 |
6 | 13 | 503.48 | 18 | 15.10 | 949 | 258 | 2.81 / 110.21 | 2 | 3 |
7 | 13 | 53.28 | 18 | 15.18 | 336 | 92 | 2.90 / 110.30 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.16 | 251 | 628 | 3.53 / 110.93 | 2 | 6 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 28 | 15.13 | 389 | 165 | 0.16 / 104.04 | 2 | 2 |
2 | 7 | 2003.88 | 31 | 14.98 | 2832 | 1315 | 1.48 / 105.36 | 2 | 2 |
3 | 13 | 1466.04 | 18 | 14.98 | 2178 | 587 | 2.07 / 105.95 | 2 | 2 |
4 | 13 | 1048.88 | 18 | 15.01 | 1653 | 447 | 2.51 / 106.39 | 2 | 2 |
5 | 13 | 604.16 | 18 | 15.08 | 1083 | 294 | 2.81 / 106.69 | 2 | 3 |
6 | 13 | 34.92 | 18 | 15.19 | 310 | 85 | 2.89 / 106.77 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.16 | 252 | 630 | 3.52 / 107.40 | 2 | 6 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 28 | 15.13 | 398 | 169 | 0.17 / 100.47 | 2 | 2 |
2 | 7 | 2002.28 | 31 | 14.98 | 2820 | 1310 | 1.48 / 101.78 | 2 | 2 |
3 | 13 | 1575.96 | 18 | 14.96 | 2319 | 624 | 2.10 / 102.40 | 2 | 2 |
4 | 13 | 1019.96 | 18 | 15.02 | 1623 | 439 | 2.54 / 102.84 | 2 | 2 |
5 | 13 | 462.56 | 18 | 15.12 | 900 | 245 | 2.79 / 103.09 | 2 | 3 |
6 | 13 | 43.04 | 18 | 15.18 | 321 | 88 | 2.87 / 103.18 | 2 | 2 |
7 | 13 | 13.84 | 18 | 15.18 | 277 | 76 | 2.95 / 103.25 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.15 | 251 | 627 | 3.58 / 103.88 | 2 | 8 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 29 | 15.13 | 392 | 172 | 0.17 / 96.91 | 2 | 2 |
2 | 3 | 970.68 | -1 | 15.48 | 0 | 0 | 0.00 / 96.91 | 2 | 2 |
3 | 7 | 2002.20 | 32 | 14.98 | 2826 | 1355 | 1.53 / 98.26 | 2 | 2 |
4 | 13 | 1593.64 | 18 | 14.97 | 2342 | 631 | 2.16 / 98.89 | 2 | 2 |
5 | 13 | 950.64 | 18 | 15.04 | 1530 | 414 | 2.57 / 99.31 | 2 | 2 |
6 | 13 | 547.64 | 18 | 15.10 | 1008 | 274 | 2.85 / 99.58 | 2 | 3 |
7 | 13 | 49.88 | 18 | 15.19 | 331 | 91 | 2.94 / 99.67 | 2 | 2 |
8 | 8 | 0.28 | 165 | 15.17 | 252 | 631 | 3.57 / 100.30 | 2 | 5 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 29 | 15.12 | 395 | 173 | 0.17 / 93.07 | 2 | 2 |
2 | 7 | 2007.84 | 31 | 14.98 | 2837 | 1317 | 1.49 / 94.39 | 2 | 2 |
3 | 13 | 1590.92 | 18 | 14.96 | 2342 | 631 | 2.12 / 95.02 | 2 | 2 |
4 | 13 | 1156.00 | 18 | 15.00 | 1791 | 484 | 2.60 / 95.50 | 2 | 2 |
5 | 13 | 703.40 | 18 | 15.07 | 1217 | 330 | 2.93 / 95.83 | 2 | 2 |
6 | 13 | 41.68 | 18 | 15.19 | 318 | 87 | 3.02 / 95.92 | 2 | 2 |
7 | 13 | 16.56 | 18 | 15.20 | 282 | 77 | 3.10 / 96.00 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.17 | 250 | 626 | 3.72 / 96.62 | 2 | 10 |
9 | 14 | 0.00 | 30 | 15.14 | 249 | 113 | 3.84 / 96.73 | 3 | 11 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 29 | 15.15 | 398 | 175 | 0.17 / 89.40 | 2 | 2 |
2 | 7 | 2002.56 | 31 | 14.99 | 2831 | 1316 | 1.49 / 90.71 | 2 | 2 |
3 | 13 | 1474.72 | 18 | 14.99 | 2202 | 594 | 2.08 / 91.31 | 2 | 2 |
4 | 13 | 1186.80 | 18 | 14.99 | 1830 | 494 | 2.58 / 91.80 | 2 | 2 |
5 | 13 | 587.20 | 18 | 15.10 | 1065 | 289 | 2.87 / 92.09 | 2 | 2 |
6 | 13 | 55.48 | 18 | 15.20 | 342 | 94 | 2.96 / 92.19 | 2 | 2 |
7 | 13 | 18.32 | 18 | 15.19 | 286 | 78 | 3.04 / 92.26 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.16 | 253 | 633 | 3.67 / 92.90 | 2 | 7 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 28 | 15.15 | 398 | 169 | 0.17 / 85.79 | 2 | 2 |
2 | 3 | 1027.52 | 1 | 15.22 | 1701 | 26 | 0.19 / 85.82 | 2 | 2 |
3 | 7 | 2002.24 | 31 | 14.99 | 2816 | 1309 | 1.50 / 87.13 | 2 | 2 |
4 | 13 | 1582.56 | 18 | 14.98 | 2329 | 628 | 2.13 / 87.75 | 2 | 2 |
5 | 13 | 1015.20 | 18 | 15.05 | 1612 | 437 | 2.57 / 88.19 | 2 | 2 |
6 | 13 | 465.76 | 18 | 15.13 | 899 | 245 | 2.81 / 88.44 | 2 | 2 |
7 | 13 | 46.44 | 18 | 15.20 | 323 | 88 | 2.90 / 88.52 | 2 | 2 |
8 | 13 | 15.04 | 18 | 15.20 | 276 | 76 | 2.98 / 88.60 | 2 | 2 |
9 | 8 | 0.04 | 165 | 15.18 | 249 | 624 | 3.60 / 89.22 | 2 | 12 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 28 | 15.16 | 391 | 166 | 0.17 / 82.29 | 2 | 2 |
2 | 7 | 2004.00 | 31 | 15.00 | 2820 | 1311 | 1.48 / 83.60 | 2 | 2 |
3 | 13 | 1566.96 | 18 | 14.99 | 2305 | 622 | 2.10 / 84.23 | 2 | 2 |
4 | 13 | 1019.68 | 18 | 15.05 | 1617 | 438 | 2.54 / 84.66 | 2 | 2 |
5 | 13 | 459.44 | 18 | 15.14 | 890 | 243 | 2.78 / 84.91 | 2 | 2 |
6 | 13 | 46.72 | 18 | 15.21 | 326 | 89 | 2.87 / 85.00 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.19 | 250 | 627 | 3.50 / 85.62 | 2 | 6 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 29 | 15.18 | 403 | 177 | 0.18 / 78.75 | 2 | 2 |
2 | 7 | 2002.12 | 31 | 15.01 | 2813 | 1309 | 1.49 / 80.06 | 2 | 2 |
3 | 13 | 1572.00 | 18 | 15.00 | 2324 | 627 | 2.11 / 80.69 | 2 | 2 |
4 | 13 | 1136.44 | 18 | 15.03 | 1774 | 480 | 2.59 / 81.17 | 2 | 2 |
5 | 13 | 427.72 | 18 | 15.15 | 853 | 233 | 2.83 / 81.40 | 2 | 3 |
6 | 13 | 60.64 | 18 | 15.21 | 347 | 95 | 2.92 / 81.49 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.20 | 253 | 635 | 3.56 / 82.13 | 2 | 8 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 28 | 15.18 | 394 | 167 | 0.17 / 75.12 | 2 | 2 |
2 | 7 | 2005.96 | 31 | 15.02 | 2821 | 1314 | 1.48 / 76.44 | 2 | 2 |
3 | 13 | 1599.12 | 18 | 15.01 | 2353 | 636 | 2.12 / 77.07 | 2 | 2 |
4 | 13 | 1156.00 | 18 | 15.04 | 1798 | 487 | 2.60 / 77.56 | 2 | 2 |
5 | 13 | 570.52 | 18 | 15.13 | 1043 | 284 | 2.89 / 77.84 | 2 | 2 |
6 | 13 | 36.28 | 18 | 15.23 | 315 | 86 | 2.97 / 77.93 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.21 | 256 | 642 | 3.62 / 78.57 | 2 | 6 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 28 | 15.17 | 403 | 171 | 0.17 / 71.45 | 2 | 2 |
2 | 7 | 2003.28 | 31 | 15.02 | 2822 | 1314 | 1.49 / 72.76 | 2 | 2 |
3 | 13 | 1585.60 | 18 | 15.01 | 2332 | 630 | 2.12 / 73.39 | 2 | 2 |
4 | 13 | 1153.64 | 18 | 15.03 | 1787 | 483 | 2.60 / 73.87 | 2 | 2 |
5 | 13 | 570.32 | 18 | 15.13 | 1042 | 284 | 2.88 / 74.16 | 2 | 2 |
6 | 13 | 73.20 | 18 | 15.22 | 355 | 97 | 2.98 / 74.25 | 2 | 2 |
7 | 13 | 17.60 | 18 | 15.22 | 279 | 76 | 3.06 / 74.33 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.20 | 249 | 624 | 3.68 / 74.96 | 2 | 6 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 28 | 15.17 | 399 | 169 | 0.17 / 67.85 | 2 | 2 |
2 | 7 | 2005.56 | 32 | 15.01 | 2828 | 1358 | 1.53 / 69.21 | 2 | 2 |
3 | 13 | 1589.24 | 18 | 15.01 | 2345 | 634 | 2.16 / 69.84 | 2 | 2 |
4 | 13 | 1148.16 | 18 | 15.04 | 1780 | 482 | 2.64 / 70.32 | 2 | 2 |
5 | 13 | 443.52 | 18 | 15.17 | 868 | 237 | 2.88 / 70.56 | 2 | 2 |
6 | 13 | 89.28 | 18 | 15.21 | 375 | 103 | 2.98 / 70.66 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.20 | 245 | 614 | 3.60 / 71.27 | 2 | 6 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 28 | 15.18 | 401 | 170 | 0.17 / 64.33 | 2 | 2 |
2 | 7 | 2005.32 | 31 | 15.01 | 2829 | 1316 | 1.49 / 65.64 | 2 | 2 |
3 | 13 | 1593.32 | 18 | 15.01 | 2337 | 631 | 2.12 / 66.27 | 2 | 2 |
4 | 13 | 1024.96 | 18 | 15.07 | 1627 | 441 | 2.56 / 66.71 | 2 | 2 |
5 | 13 | 472.80 | 18 | 15.15 | 905 | 247 | 2.81 / 66.96 | 2 | 2 |
6 | 13 | 93.08 | 18 | 15.21 | 380 | 104 | 2.91 / 67.07 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.21 | 244 | 612 | 3.52 / 67.68 | 2 | 5 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.08 | 28 | 15.20 | 391 | 166 | 0.17 / 60.53 | 2 | 2 |
2 | 3 | 1019.24 | 1 | 15.26 | 1701 | 26 | 0.19 / 60.56 | 2 | 2 |
3 | 7 | 2003.76 | 31 | 15.03 | 2828 | 1318 | 1.51 / 61.88 | 2 | 2 |
4 | 13 | 1569.32 | 18 | 15.03 | 2310 | 625 | 2.13 / 62.50 | 2 | 2 |
5 | 13 | 1136.04 | 18 | 15.06 | 1773 | 481 | 2.62 / 62.98 | 2 | 2 |
6 | 13 | 686.96 | 18 | 15.12 | 1193 | 325 | 2.94 / 63.31 | 2 | 2 |
7 | 13 | 106.16 | 18 | 15.22 | 402 | 110 | 3.05 / 63.42 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.22 | 249 | 625 | 3.68 / 64.04 | 2 | 6 |
9 | 14 | 0.04 | 30 | 15.20 | 248 | 113 | 3.79 / 64.15 | 3 | 5 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 28 | 15.18 | 401 | 170 | 0.17 / 56.94 | 2 | 2 |
2 | 7 | 2001.92 | 31 | 15.05 | 2821 | 1316 | 1.49 / 58.25 | 2 | 2 |
3 | 13 | 1584.84 | 18 | 15.03 | 2330 | 630 | 2.12 / 58.88 | 2 | 2 |
4 | 13 | 1157.28 | 18 | 15.06 | 1797 | 487 | 2.60 / 59.37 | 2 | 2 |
5 | 13 | 578.76 | 18 | 15.15 | 1049 | 286 | 2.89 / 59.66 | 2 | 2 |
6 | 13 | 77.56 | 18 | 15.23 | 360 | 99 | 2.99 / 59.76 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.22 | 243 | 610 | 3.60 / 60.37 | 2 | 3 |
Average= | 3.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 27 | 15.19 | 402 | 165 | 0.16 / 53.39 | 2 | 2 |
2 | 3 | 1044.68 | 1 | 15.25 | 1705 | 26 | 0.19 / 53.42 | 2 | 2 |
3 | 7 | 2003.24 | 31 | 15.03 | 2827 | 1317 | 1.51 / 54.73 | 2 | 2 |
4 | 13 | 1578.08 | 18 | 15.02 | 2329 | 630 | 2.14 / 55.36 | 2 | 2 |
5 | 13 | 1015.32 | 18 | 15.08 | 1616 | 439 | 2.58 / 55.80 | 2 | 2 |
6 | 13 | 465.64 | 18 | 15.17 | 897 | 245 | 2.82 / 56.05 | 2 | 2 |
7 | 13 | 88.92 | 18 | 15.23 | 376 | 103 | 2.92 / 56.15 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.22 | 246 | 618 | 3.54 / 56.77 | 2 | 6 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 27 | 15.19 | 402 | 165 | 0.16 / 49.78 | 2 | 2 |
2 | 7 | 2002.20 | 31 | 15.06 | 2830 | 1321 | 1.49 / 51.10 | 2 | 2 |
3 | 13 | 1578.12 | 18 | 15.03 | 2325 | 629 | 2.12 / 51.73 | 2 | 2 |
4 | 13 | 1145.48 | 18 | 15.07 | 1785 | 484 | 2.60 / 52.22 | 2 | 2 |
5 | 13 | 574.16 | 18 | 15.15 | 1052 | 287 | 2.89 / 52.50 | 2 | 2 |
6 | 13 | 74.32 | 18 | 15.24 | 358 | 98 | 2.98 / 52.60 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.23 | 248 | 623 | 3.61 / 53.22 | 2 | 7 |
Average= | 3.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 27 | 15.20 | 398 | 163 | 0.16 / 46.12 | 2 | 2 |
2 | 7 | 2007.12 | 31 | 15.02 | 2825 | 1315 | 1.48 / 47.44 | 2 | 2 |
3 | 13 | 1576.84 | 18 | 15.03 | 2326 | 629 | 2.11 / 48.06 | 2 | 2 |
4 | 13 | 1017.88 | 18 | 15.09 | 1629 | 442 | 2.55 / 48.51 | 2 | 2 |
5 | 13 | 472.88 | 18 | 15.17 | 922 | 252 | 2.80 / 48.76 | 2 | 2 |
6 | 13 | 80.16 | 18 | 15.24 | 372 | 102 | 2.90 / 48.86 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.23 | 255 | 641 | 3.55 / 49.50 | 2 | 4 |
8 | 14 | 0.04 | 30 | 15.21 | 253 | 115 | 3.66 / 49.62 | 3 | 8 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 26 | 15.20 | 401 | 158 | 0.16 / 42.55 | 2 | 2 |
2 | 7 | 2002.48 | 31 | 15.04 | 2837 | 1323 | 1.48 / 43.87 | 2 | 2 |
3 | 13 | 1563.32 | 18 | 15.04 | 2306 | 624 | 2.11 / 44.50 | 2 | 2 |
4 | 13 | 1008.44 | 18 | 15.10 | 1617 | 440 | 2.54 / 44.94 | 2 | 2 |
5 | 13 | 577.96 | 18 | 15.16 | 1055 | 288 | 2.83 / 45.23 | 2 | 2 |
6 | 13 | 60.24 | 18 | 15.26 | 344 | 94 | 2.93 / 45.32 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.24 | 253 | 636 | 3.56 / 45.96 | 2 | 4 |
Average= | 3.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 26 | 15.22 | 397 | 157 | 0.16 / 39.02 | 2 | 2 |
2 | 7 | 2002.04 | 31 | 15.05 | 2838 | 1324 | 1.48 / 40.35 | 2 | 2 |
3 | 13 | 1479.36 | 18 | 15.06 | 2209 | 599 | 2.08 / 40.95 | 2 | 2 |
4 | 13 | 1066.88 | 18 | 15.10 | 1688 | 459 | 2.54 / 41.41 | 2 | 2 |
5 | 13 | 495.76 | 18 | 15.18 | 948 | 259 | 2.80 / 41.66 | 2 | 2 |
6 | 13 | 45.96 | 18 | 15.26 | 325 | 89 | 2.89 / 41.75 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.24 | 254 | 639 | 3.53 / 42.39 | 2 | 6 |
Average= | 3.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 27 | 15.21 | 401 | 165 | 0.16 / 35.49 | 2 | 2 |
2 | 7 | 2008.48 | 31 | 15.06 | 2840 | 1326 | 1.49 / 36.81 | 2 | 2 |
3 | 13 | 1482.72 | 18 | 15.06 | 2201 | 597 | 2.09 / 37.41 | 2 | 2 |
4 | 13 | 1064.36 | 18 | 15.09 | 1679 | 456 | 2.54 / 37.87 | 2 | 2 |
5 | 13 | 504.20 | 18 | 15.18 | 959 | 262 | 2.81 / 38.13 | 2 | 2 |
6 | 13 | 41.16 | 18 | 15.27 | 323 | 89 | 2.89 / 38.22 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.25 | 258 | 649 | 3.54 / 38.87 | 2 | 7 |
Average= | 3.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 26 | 15.22 | 406 | 161 | 0.16 / 31.94 | 2 | 2 |
2 | 3 | 1025.80 | 1 | 15.28 | 1701 | 26 | 0.19 / 31.97 | 2 | 2 |
3 | 7 | 2002.72 | 31 | 15.05 | 2830 | 1320 | 1.51 / 33.29 | 2 | 2 |
4 | 13 | 1568.80 | 18 | 15.05 | 2317 | 628 | 2.13 / 33.92 | 2 | 2 |
5 | 13 | 1011.52 | 18 | 15.11 | 1615 | 439 | 2.57 / 34.35 | 2 | 2 |
6 | 13 | 459.72 | 18 | 15.18 | 892 | 244 | 2.82 / 34.60 | 2 | 2 |
7 | 13 | 37.76 | 18 | 15.27 | 314 | 86 | 2.90 / 34.68 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.25 | 254 | 639 | 3.54 / 35.32 | 2 | 5 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 27 | 15.23 | 403 | 166 | 0.17 / 28.35 | 2 | 2 |
2 | 3 | 979.96 | -1 | 15.54 | 0 | 0 | 0.00 / 28.35 | 2 | 2 |
3 | 7 | 2004.92 | 31 | 15.07 | 2841 | 1327 | 1.49 / 29.68 | 2 | 2 |
4 | 13 | 1590.56 | 18 | 15.05 | 2338 | 633 | 2.13 / 30.31 | 2 | 2 |
5 | 13 | 1029.92 | 18 | 15.11 | 1640 | 446 | 2.57 / 30.76 | 2 | 2 |
6 | 13 | 601.04 | 18 | 15.17 | 1083 | 296 | 2.87 / 31.05 | 2 | 2 |
7 | 13 | 66.04 | 18 | 15.27 | 351 | 96 | 2.96 / 31.15 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.25 | 251 | 632 | 3.60 / 31.78 | 2 | 7 |
Average= | 3.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 28 | 15.23 | 401 | 171 | 0.17 / 24.75 | 2 | 2 |
2 | 3 | 966.00 | -1 | 15.55 | 0 | 0 | 0.00 / 24.75 | 2 | 2 |
3 | 7 | 2001.44 | 32 | 15.07 | 2840 | 1370 | 1.54 / 26.12 | 2 | 2 |
4 | 13 | 1573.72 | 18 | 15.05 | 2325 | 630 | 2.17 / 26.75 | 2 | 2 |
5 | 13 | 1010.96 | 18 | 15.11 | 1624 | 442 | 2.61 / 27.19 | 2 | 2 |
6 | 13 | 444.64 | 18 | 15.20 | 882 | 241 | 2.85 / 27.44 | 2 | 2 |
7 | 13 | 63.64 | 18 | 15.29 | 352 | 97 | 2.95 / 27.53 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.26 | 259 | 652 | 3.60 / 28.18 | 2 | 6 |
Average= | 3.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 28 | 15.25 | 393 | 168 | 0.17 / 21.20 | 2 | 2 |
2 | 7 | 2005.44 | 38 | 15.01 | 2828 | 1613 | 1.78 / 22.81 | 2 | 2 |
3 | 13 | 1400.44 | 18 | 15.08 | 2115 | 574 | 2.35 / 23.39 | 2 | 2 |
4 | 13 | 841.52 | 18 | 15.14 | 1398 | 381 | 2.74 / 23.77 | 2 | 2 |
5 | 13 | 267.28 | 18 | 15.24 | 631 | 173 | 2.91 / 23.94 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.27 | 255 | 642 | 3.55 / 24.58 | 2 | 7 |
Average= | 3.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 26 | 15.24 | 409 | 162 | 0.16 / 17.47 | 2 | 2 |
2 | 10 | 1013.60 | 2 | 15.26 | 1667 | 51 | 0.21 / 17.52 | 2 | 2 |
3 | 7 | 2006.12 | 38 | 15.03 | 2832 | 1617 | 1.83 / 19.14 | 2 | 2 |
4 | 13 | 1407.04 | 18 | 15.09 | 2117 | 575 | 2.41 / 19.72 | 2 | 2 |
5 | 13 | 845.20 | 18 | 15.15 | 1403 | 383 | 2.79 / 20.10 | 2 | 2 |
6 | 13 | 267.60 | 18 | 15.26 | 633 | 174 | 2.96 / 20.27 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.28 | 255 | 643 | 3.60 / 20.91 | 2 | 8 |
8 | 14 | 0.24 | 30 | 15.26 | 253 | 116 | 3.72 / 21.03 | 2 | 5 |
Average= | 3.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 29 | 15.24 | 394 | 174 | 0.17 / 13.84 | 2 | 2 |
2 | 3 | 861.80 | -4 | 15.54 | 0 | 0 | 0.00 / 13.84 | 2 | 2 |
3 | 7 | 2002.68 | 39 | 15.03 | 2819 | 1652 | 1.83 / 15.49 | 2 | 2 |
4 | 13 | 1288.40 | 18 | 15.11 | 1968 | 535 | 2.36 / 16.03 | 2 | 2 |
5 | 13 | 862.60 | 18 | 15.15 | 1424 | 388 | 2.75 / 16.42 | 2 | 2 |
6 | 13 | 276.04 | 18 | 15.26 | 644 | 177 | 2.93 / 16.59 | 2 | 2 |
7 | 13 | 22.84 | 18 | 15.30 | 291 | 80 | 3.01 / 16.67 | 2 | 2 |
8 | 8 | -0.08 | 165 | 15.27 | 253 | 637 | 3.64 / 17.31 | 2 | 4 |
Average= | 2.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 25 | 15.25 | 389 | 148 | 0.15 / 10.78 | 2 | 2 |
2 | 7 | 1525.84 | 38 | 15.12 | 2221 | 1276 | 1.42 / 12.06 | 2 | 2 |
3 | 13 | 1260.28 | 18 | 15.14 | 1910 | 521 | 1.94 / 12.58 | 2 | 2 |
4 | 13 | 705.56 | 18 | 15.19 | 1215 | 332 | 2.28 / 12.91 | 2 | 2 |
5 | 13 | 130.20 | 18 | 15.29 | 442 | 122 | 2.40 / 13.03 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.29 | 250 | 631 | 3.03 / 13.67 | 2 | 6 |
Average= | 2.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 24 | 15.25 | 391 | 143 | 0.14 / 7.69 | 2 | 2 |
2 | 3 | 1016.72 | 1 | 15.32 | 1694 | 26 | 0.17 / 7.72 | 2 | 2 |
3 | 7 | 1523.88 | 39 | 15.13 | 2226 | 1313 | 1.48 / 9.03 | 2 | 2 |
4 | 13 | 1261.20 | 18 | 15.14 | 1913 | 521 | 2.00 / 9.55 | 2 | 2 |
5 | 13 | 706.08 | 18 | 15.20 | 1214 | 332 | 2.34 / 9.88 | 2 | 2 |
6 | 13 | 131.12 | 18 | 15.28 | 440 | 121 | 2.46 / 10.00 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.28 | 251 | 633 | 3.09 / 10.64 | 2 | 7 |
Average= | 2.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 32 | 15.29 | 411 | 201 | 0.20 / 4.33 | 2 | 2 |
2 | 3 | 732.92 | -5 | 15.56 | 0 | 0 | 0.00 / 4.33 | 2 | 2 |
3 | 3 | 933.28 | -1 | 15.58 | 0 | 0 | 0.00 / 4.33 | 2 | 2 |
4 | 7 | 1518.24 | 74 | 15.06 | 2207 | 2460 | 2.66 / 6.79 | 2 | 2 |
5 | 13 | 152.56 | 18 | 15.29 | 467 | 129 | 2.79 / 6.92 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.29 | 249 | 628 | 3.42 / 7.55 | 2 | 6 |
Average= | 2.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 27 | 15.46 | 384 | 160 | 0.16 / 1.69 | 2 | 2 |
2 | 3 | 930.68 | -1 | 15.59 | 0 | 0 | 0.00 / 1.69 | 2 | 2 |
3 | 3 | 972.24 | -1 | 15.61 | 0 | 0 | 0.00 / 1.69 | 2 | 2 |
4 | 7 | 1006.76 | 74 | 15.20 | 1564 | 1759 | 1.92 / 3.45 | 2 | 2 |
5 | 8 | 0.20 | 165 | 15.34 | 268 | 678 | 2.60 / 4.13 | 2 | 8 |
Average= | 2.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 133.80 | 26 | 15.58 | 436 | 177 | 0.18 / 0.18 | 2 | 2 |
2 | 7 | 147.48 | 74 | 15.54 | 430 | 494 | 0.67 / 0.67 | 2 | 2 |
3 | 8 | 0.08 | 240 | 15.51 | 231 | 860 | 1.53 / 1.53 | 2 | 7 |
Average= | 1.53 (KJ/cycle) |