SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 31 | 14.96 | 413 | 192 | 0.19 / 493.87 | 2 | 2 |
2 | 7 | 2004.24 | 31 | 14.77 | 2959 | 1355 | 1.55 / 495.22 | 2 | 3 |
3 | 13 | 1840.64 | 23 | 14.69 | 2751 | 929 | 2.48 / 496.15 | 2 | 3 |
4 | 13 | 1206.76 | 23 | 14.74 | 1924 | 652 | 3.13 / 496.80 | 2 | 4 |
5 | 13 | 434.60 | 23 | 14.89 | 886 | 303 | 3.43 / 497.11 | 2 | 3 |
6 | 13 | 18.68 | 23 | 15.01 | 280 | 97 | 3.53 / 497.20 | 2 | 4 |
7 | 8 | 0.04 | 165 | 14.98 | 250 | 618 | 4.15 / 497.82 | 2 | 4 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 31 | 14.95 | 413 | 191 | 0.19 / 489.96 | 2 | 2 |
2 | 7 | 2004.88 | 30 | 14.79 | 2972 | 1319 | 1.51 / 491.28 | 2 | 2 |
3 | 13 | 1646.56 | 23 | 14.74 | 2507 | 850 | 2.36 / 492.13 | 2 | 3 |
4 | 13 | 1137.72 | 23 | 14.77 | 1846 | 627 | 2.99 / 492.76 | 2 | 3 |
5 | 13 | 417.60 | 23 | 14.91 | 865 | 297 | 3.28 / 493.05 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.99 | 252 | 623 | 3.91 / 493.68 | 2 | 4 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 31 | 14.95 | 407 | 189 | 0.19 / 485.93 | 2 | 2 |
2 | 7 | 2005.48 | 30 | 14.79 | 2964 | 1315 | 1.50 / 487.25 | 2 | 3 |
3 | 13 | 1754.32 | 23 | 14.74 | 2652 | 899 | 2.40 / 488.15 | 2 | 3 |
4 | 13 | 1131.16 | 23 | 14.77 | 1841 | 625 | 3.03 / 488.77 | 2 | 3 |
5 | 13 | 384.60 | 23 | 14.93 | 814 | 280 | 3.31 / 489.05 | 2 | 3 |
6 | 13 | 20.52 | 23 | 15.02 | 284 | 98 | 3.41 / 489.15 | 2 | 3 |
7 | 8 | 0.04 | 165 | 14.99 | 250 | 618 | 4.02 / 489.77 | 2 | 3 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 31 | 14.96 | 411 | 191 | 0.19 / 481.80 | 2 | 2 |
2 | 7 | 2011.96 | 31 | 14.78 | 2982 | 1366 | 1.56 / 483.17 | 2 | 3 |
3 | 13 | 1798.00 | 23 | 14.70 | 2696 | 912 | 2.47 / 484.08 | 2 | 3 |
4 | 13 | 1182.04 | 23 | 14.75 | 1905 | 646 | 3.11 / 484.72 | 2 | 4 |
5 | 13 | 415.84 | 23 | 14.91 | 864 | 296 | 3.41 / 485.02 | 2 | 4 |
6 | 13 | 24.92 | 23 | 15.01 | 293 | 101 | 3.51 / 485.12 | 2 | 2 |
7 | 8 | 0.00 | 165 | 14.98 | 252 | 623 | 4.13 / 485.74 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 31 | 14.95 | 416 | 193 | 0.19 / 477.97 | 2 | 2 |
2 | 7 | 2003.24 | 30 | 14.79 | 2964 | 1315 | 1.51 / 479.28 | 2 | 3 |
3 | 13 | 1620.60 | 23 | 14.74 | 2476 | 839 | 2.35 / 480.12 | 2 | 3 |
4 | 13 | 1068.40 | 23 | 14.78 | 1753 | 596 | 2.94 / 480.72 | 2 | 4 |
5 | 13 | 363.64 | 23 | 14.94 | 783 | 269 | 3.21 / 480.99 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.00 | 252 | 624 | 3.84 / 481.61 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 31 | 14.95 | 414 | 192 | 0.19 / 474.20 | 2 | 2 |
2 | 7 | 2005.08 | 30 | 14.79 | 2973 | 1319 | 1.51 / 475.52 | 2 | 2 |
3 | 13 | 1603.84 | 23 | 14.75 | 2450 | 831 | 2.34 / 476.35 | 2 | 3 |
4 | 13 | 1018.64 | 23 | 14.80 | 1686 | 574 | 2.92 / 476.93 | 2 | 4 |
5 | 13 | 270.80 | 23 | 14.96 | 641 | 221 | 3.14 / 477.15 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.00 | 252 | 624 | 3.76 / 477.77 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 31 | 14.97 | 411 | 191 | 0.19 / 470.46 | 2 | 2 |
2 | 7 | 2007.56 | 30 | 14.78 | 2958 | 1312 | 1.50 / 471.77 | 2 | 3 |
3 | 13 | 1606.40 | 23 | 14.74 | 2455 | 832 | 2.33 / 472.61 | 2 | 3 |
4 | 13 | 1006.12 | 23 | 14.79 | 1667 | 567 | 2.90 / 473.17 | 2 | 5 |
5 | 13 | 266.64 | 23 | 14.96 | 638 | 220 | 3.12 / 473.39 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.99 | 251 | 621 | 3.74 / 474.01 | 2 | 5 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 31 | 14.96 | 418 | 194 | 0.19 / 466.69 | 2 | 2 |
2 | 7 | 2013.08 | 30 | 14.78 | 2984 | 1323 | 1.52 / 468.01 | 2 | 3 |
3 | 13 | 1609.00 | 23 | 14.75 | 2461 | 835 | 2.35 / 468.84 | 2 | 3 |
4 | 13 | 1018.84 | 23 | 14.79 | 1693 | 576 | 2.93 / 469.42 | 2 | 4 |
5 | 13 | 275.40 | 23 | 14.98 | 652 | 225 | 3.15 / 469.64 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.00 | 253 | 626 | 3.78 / 470.27 | 2 | 6 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 31 | 14.97 | 423 | 196 | 0.20 / 462.91 | 2 | 2 |
2 | 7 | 2010.16 | 30 | 14.78 | 2969 | 1316 | 1.51 / 464.23 | 2 | 2 |
3 | 13 | 1611.84 | 23 | 14.74 | 2465 | 836 | 2.35 / 465.06 | 2 | 3 |
4 | 13 | 1015.76 | 23 | 14.79 | 1683 | 573 | 2.92 / 465.64 | 2 | 3 |
5 | 13 | 279.64 | 23 | 14.96 | 658 | 226 | 3.15 / 465.86 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.00 | 254 | 629 | 3.78 / 466.49 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 31 | 14.97 | 413 | 192 | 0.19 / 459.04 | 2 | 2 |
2 | 7 | 2008.84 | 30 | 14.79 | 2962 | 1314 | 1.51 / 460.36 | 2 | 2 |
3 | 13 | 1739.88 | 23 | 14.73 | 2624 | 889 | 2.39 / 461.25 | 2 | 2 |
4 | 13 | 991.64 | 23 | 14.80 | 1651 | 562 | 2.96 / 461.81 | 2 | 3 |
5 | 13 | 375.12 | 23 | 14.92 | 806 | 277 | 3.23 / 462.08 | 2 | 4 |
6 | 8 | 0.04 | 165 | 15.00 | 255 | 631 | 3.86 / 462.72 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 31 | 14.98 | 416 | 193 | 0.19 / 455.26 | 2 | 2 |
2 | 7 | 2007.48 | 30 | 14.78 | 2969 | 1316 | 1.51 / 456.58 | 2 | 3 |
3 | 13 | 1615.72 | 23 | 14.73 | 2471 | 837 | 2.35 / 457.42 | 2 | 2 |
4 | 13 | 1029.16 | 23 | 14.80 | 1699 | 578 | 2.93 / 458.00 | 2 | 2 |
5 | 13 | 280.64 | 23 | 14.96 | 663 | 228 | 3.15 / 458.22 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.01 | 253 | 627 | 3.78 / 458.85 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 31 | 14.97 | 425 | 197 | 0.20 / 451.47 | 2 | 2 |
2 | 7 | 2006.88 | 30 | 14.80 | 2967 | 1317 | 1.51 / 452.79 | 2 | 2 |
3 | 13 | 1605.48 | 23 | 14.76 | 2458 | 834 | 2.35 / 453.62 | 2 | 4 |
4 | 13 | 1028.80 | 23 | 14.80 | 1702 | 579 | 2.93 / 454.20 | 2 | 3 |
5 | 13 | 292.72 | 23 | 14.97 | 683 | 235 | 3.16 / 454.44 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.01 | 257 | 636 | 3.80 / 455.07 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 31 | 14.97 | 423 | 196 | 0.20 / 447.62 | 2 | 2 |
2 | 7 | 2002.64 | 31 | 14.79 | 2965 | 1359 | 1.56 / 448.98 | 2 | 3 |
3 | 13 | 1722.12 | 23 | 14.73 | 2598 | 880 | 2.44 / 449.86 | 2 | 4 |
4 | 13 | 999.00 | 23 | 14.80 | 1660 | 565 | 3.00 / 450.42 | 2 | 4 |
5 | 13 | 275.48 | 23 | 14.97 | 651 | 224 | 3.23 / 450.65 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.01 | 253 | 627 | 3.85 / 451.27 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 31 | 14.96 | 426 | 198 | 0.20 / 443.74 | 2 | 2 |
2 | 7 | 2009.32 | 31 | 14.80 | 2983 | 1369 | 1.57 / 445.11 | 2 | 4 |
3 | 13 | 1742.04 | 23 | 14.72 | 2623 | 888 | 2.45 / 446.00 | 2 | 3 |
4 | 13 | 1003.68 | 23 | 14.80 | 1671 | 569 | 3.02 / 446.56 | 2 | 3 |
5 | 13 | 271.04 | 23 | 14.97 | 651 | 224 | 3.25 / 446.79 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.01 | 255 | 632 | 3.88 / 447.42 | 2 | 2 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 31 | 14.98 | 419 | 195 | 0.19 / 439.92 | 2 | 2 |
2 | 7 | 2006.28 | 30 | 14.80 | 2968 | 1318 | 1.51 / 441.24 | 2 | 4 |
3 | 13 | 1735.84 | 23 | 14.74 | 2630 | 892 | 2.40 / 442.13 | 2 | 3 |
4 | 13 | 983.24 | 23 | 14.82 | 1645 | 561 | 2.96 / 442.69 | 2 | 3 |
5 | 13 | 242.08 | 23 | 14.98 | 614 | 212 | 3.18 / 442.90 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.01 | 259 | 641 | 3.82 / 443.54 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 31 | 14.97 | 416 | 193 | 0.19 / 436.16 | 2 | 2 |
2 | 7 | 2003.24 | 30 | 14.81 | 2972 | 1320 | 1.51 / 437.48 | 2 | 3 |
3 | 13 | 1601.88 | 23 | 14.76 | 2450 | 832 | 2.35 / 438.31 | 2 | 3 |
4 | 13 | 1008.16 | 23 | 14.82 | 1677 | 572 | 2.92 / 438.88 | 2 | 4 |
5 | 13 | 242.92 | 23 | 14.98 | 610 | 210 | 3.13 / 439.09 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.01 | 256 | 634 | 3.76 / 439.72 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 31 | 14.97 | 412 | 191 | 0.19 / 432.38 | 2 | 2 |
2 | 7 | 2008.04 | 30 | 14.81 | 2975 | 1322 | 1.51 / 433.70 | 2 | 3 |
3 | 13 | 1609.08 | 23 | 14.76 | 2462 | 836 | 2.35 / 434.54 | 2 | 3 |
4 | 13 | 1016.64 | 23 | 14.82 | 1694 | 577 | 2.93 / 435.11 | 2 | 5 |
5 | 13 | 255.40 | 23 | 14.98 | 627 | 216 | 3.14 / 435.33 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.02 | 255 | 632 | 3.77 / 435.96 | 2 | 5 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 31 | 14.98 | 417 | 194 | 0.19 / 428.64 | 2 | 2 |
2 | 7 | 2010.92 | 30 | 14.80 | 2963 | 1316 | 1.51 / 429.95 | 2 | 3 |
3 | 13 | 1605.48 | 23 | 14.76 | 2454 | 833 | 2.34 / 430.79 | 2 | 3 |
4 | 13 | 1008.76 | 23 | 14.81 | 1676 | 571 | 2.91 / 431.36 | 2 | 4 |
5 | 13 | 247.24 | 23 | 14.99 | 610 | 210 | 3.12 / 431.57 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.02 | 251 | 622 | 3.75 / 432.19 | 2 | 5 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 31 | 14.98 | 415 | 193 | 0.19 / 424.86 | 2 | 2 |
2 | 7 | 2010.40 | 30 | 14.81 | 2975 | 1322 | 1.51 / 426.18 | 2 | 2 |
3 | 13 | 1613.84 | 23 | 14.78 | 2467 | 839 | 2.35 / 427.02 | 2 | 3 |
4 | 13 | 1016.52 | 23 | 14.84 | 1691 | 577 | 2.93 / 427.60 | 2 | 5 |
5 | 13 | 264.00 | 23 | 15.00 | 638 | 220 | 3.15 / 427.82 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.03 | 252 | 625 | 3.78 / 428.44 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 31 | 14.98 | 419 | 195 | 0.19 / 421.02 | 2 | 2 |
2 | 7 | 2009.88 | 31 | 14.80 | 2961 | 1359 | 1.55 / 422.37 | 2 | 3 |
3 | 13 | 1735.00 | 23 | 14.74 | 2620 | 888 | 2.44 / 423.26 | 2 | 3 |
4 | 13 | 1003.04 | 23 | 14.81 | 1667 | 568 | 3.01 / 423.83 | 2 | 4 |
5 | 13 | 252.40 | 23 | 15.00 | 621 | 214 | 3.22 / 424.05 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.02 | 251 | 622 | 3.85 / 424.67 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 31 | 14.97 | 397 | 184 | 0.18 / 417.21 | 2 | 2 |
2 | 7 | 2003.80 | 31 | 14.81 | 2962 | 1360 | 1.54 / 418.57 | 2 | 3 |
3 | 13 | 1609.08 | 23 | 14.75 | 2453 | 832 | 2.38 / 419.40 | 2 | 4 |
4 | 13 | 1021.68 | 23 | 14.81 | 1694 | 577 | 2.95 / 419.98 | 2 | 3 |
5 | 13 | 257.80 | 23 | 14.98 | 626 | 216 | 3.17 / 420.20 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.01 | 253 | 627 | 3.80 / 420.82 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 31 | 14.96 | 394 | 183 | 0.18 / 413.47 | 2 | 2 |
2 | 7 | 2004.92 | 30 | 14.79 | 2967 | 1316 | 1.50 / 414.79 | 2 | 3 |
3 | 13 | 1598.72 | 23 | 14.75 | 2441 | 828 | 2.33 / 415.61 | 2 | 3 |
4 | 13 | 1011.72 | 23 | 14.80 | 1678 | 571 | 2.90 / 416.18 | 2 | 3 |
5 | 13 | 250.56 | 23 | 14.97 | 619 | 213 | 3.11 / 416.40 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.00 | 254 | 629 | 3.74 / 417.03 | 2 | 6 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 31 | 14.96 | 391 | 181 | 0.18 / 409.72 | 2 | 2 |
2 | 7 | 2011.20 | 30 | 14.80 | 2972 | 1320 | 1.50 / 411.04 | 2 | 3 |
3 | 13 | 1610.96 | 23 | 14.75 | 2462 | 835 | 2.34 / 411.87 | 2 | 3 |
4 | 13 | 1017.84 | 23 | 14.80 | 1690 | 575 | 2.91 / 412.45 | 2 | 4 |
5 | 13 | 251.04 | 23 | 14.97 | 618 | 213 | 3.12 / 412.66 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.00 | 253 | 626 | 3.75 / 413.29 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 31 | 14.97 | 405 | 188 | 0.19 / 406.01 | 2 | 2 |
2 | 7 | 2003.40 | 31 | 14.78 | 2957 | 1355 | 1.54 / 407.37 | 2 | 3 |
3 | 13 | 1612.52 | 23 | 14.75 | 2463 | 836 | 2.38 / 408.20 | 2 | 3 |
4 | 13 | 914.36 | 23 | 14.82 | 1549 | 528 | 2.91 / 408.73 | 2 | 3 |
5 | 13 | 200.08 | 23 | 14.99 | 542 | 187 | 3.09 / 408.92 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.00 | 249 | 616 | 3.71 / 409.54 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.84 | 31 | 14.98 | 413 | 192 | 0.19 / 402.25 | 2 | 2 |
2 | 7 | 2005.60 | 30 | 14.80 | 2967 | 1317 | 1.51 / 403.56 | 2 | 3 |
3 | 13 | 1608.36 | 23 | 14.76 | 2461 | 835 | 2.34 / 404.40 | 2 | 2 |
4 | 13 | 1039.12 | 23 | 14.80 | 1715 | 584 | 2.93 / 404.98 | 2 | 5 |
5 | 13 | 273.76 | 23 | 14.97 | 650 | 224 | 3.15 / 405.21 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.01 | 250 | 619 | 3.77 / 405.83 | 2 | 2 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 31 | 14.97 | 398 | 185 | 0.18 / 398.33 | 2 | 2 |
2 | 7 | 2008.08 | 31 | 14.80 | 2973 | 1364 | 1.55 / 399.69 | 2 | 4 |
3 | 13 | 1618.24 | 23 | 14.76 | 2469 | 838 | 2.39 / 400.53 | 2 | 3 |
4 | 13 | 1010.64 | 23 | 14.81 | 1679 | 572 | 2.96 / 401.10 | 2 | 4 |
5 | 13 | 269.72 | 23 | 14.98 | 646 | 223 | 3.18 / 401.32 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.02 | 250 | 620 | 3.80 / 401.94 | 2 | 2 |
7 | 14 | 0.20 | 30 | 15.00 | 252 | 113 | 3.91 / 402.05 | 2 | 6 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 30 | 14.98 | 412 | 185 | 0.19 / 394.58 | 2 | 2 |
2 | 7 | 2008.12 | 30 | 14.80 | 2968 | 1318 | 1.50 / 395.90 | 2 | 2 |
3 | 13 | 1599.00 | 23 | 14.75 | 2448 | 830 | 2.33 / 396.73 | 2 | 3 |
4 | 13 | 1006.52 | 23 | 14.81 | 1671 | 569 | 2.90 / 397.30 | 2 | 5 |
5 | 13 | 262.80 | 23 | 14.98 | 634 | 218 | 3.12 / 397.52 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.02 | 251 | 622 | 3.74 / 398.14 | 2 | 7 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 31 | 15.00 | 395 | 184 | 0.18 / 390.72 | 2 | 2 |
2 | 7 | 2002.76 | 30 | 14.80 | 2955 | 1312 | 1.50 / 392.03 | 2 | 3 |
3 | 13 | 1610.00 | 23 | 14.77 | 2466 | 838 | 2.33 / 392.86 | 2 | 3 |
4 | 13 | 1027.32 | 23 | 14.81 | 1697 | 578 | 2.91 / 393.44 | 2 | 3 |
5 | 13 | 276.52 | 23 | 14.99 | 655 | 226 | 3.14 / 393.67 | 2 | 3 |
6 | 13 | 21.44 | 23 | 15.04 | 288 | 100 | 3.24 / 393.77 | 2 | 3 |
7 | 8 | -0.08 | 165 | 15.01 | 254 | 629 | 3.87 / 394.40 | 2 | 5 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 31 | 14.99 | 419 | 195 | 0.19 / 386.82 | 2 | 2 |
2 | 7 | 2001.68 | 30 | 14.81 | 2968 | 1319 | 1.51 / 388.14 | 2 | 4 |
3 | 13 | 1714.76 | 23 | 14.77 | 2598 | 883 | 2.40 / 389.03 | 2 | 2 |
4 | 13 | 971.60 | 23 | 14.84 | 1632 | 557 | 2.95 / 389.58 | 2 | 3 |
5 | 13 | 233.84 | 23 | 15.01 | 592 | 204 | 3.16 / 389.79 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.04 | 254 | 630 | 3.79 / 390.42 | 2 | 2 |
7 | 14 | -0.04 | 30 | 15.02 | 253 | 114 | 3.90 / 390.53 | 2 | 4 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 31 | 14.99 | 386 | 179 | 0.18 / 382.83 | 2 | 2 |
2 | 7 | 2006.12 | 30 | 14.83 | 2971 | 1322 | 1.50 / 384.15 | 2 | 3 |
3 | 13 | 1585.44 | 23 | 14.79 | 2437 | 829 | 2.33 / 384.98 | 2 | 3 |
4 | 13 | 1003.68 | 23 | 14.83 | 1671 | 570 | 2.90 / 385.55 | 2 | 3 |
5 | 13 | 249.32 | 23 | 15.00 | 617 | 213 | 3.11 / 385.77 | 2 | 3 |
6 | 13 | 38.32 | 23 | 15.04 | 319 | 110 | 3.22 / 385.88 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.02 | 257 | 637 | 3.86 / 386.51 | 2 | 4 |
8 | 14 | 0.12 | 30 | 15.00 | 258 | 116 | 3.98 / 386.63 | 2 | 5 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 31 | 14.97 | 409 | 190 | 0.19 / 378.87 | 2 | 2 |
2 | 7 | 2007.80 | 30 | 14.80 | 2967 | 1317 | 1.51 / 380.19 | 2 | 2 |
3 | 13 | 1879.64 | 23 | 14.73 | 2801 | 949 | 2.46 / 381.14 | 2 | 4 |
4 | 13 | 1074.68 | 23 | 14.81 | 1765 | 601 | 3.06 / 381.74 | 2 | 6 |
5 | 13 | 196.16 | 23 | 15.02 | 538 | 186 | 3.24 / 381.93 | 2 | 3 |
6 | 13 | 18.16 | 23 | 15.05 | 285 | 99 | 3.34 / 382.03 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.02 | 253 | 627 | 3.97 / 382.65 | 2 | 7 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 31 | 14.99 | 391 | 182 | 0.18 / 375.02 | 2 | 2 |
2 | 7 | 2013.92 | 30 | 14.83 | 2975 | 1324 | 1.51 / 376.34 | 2 | 2 |
3 | 13 | 1621.48 | 23 | 14.77 | 2470 | 839 | 2.34 / 377.18 | 2 | 3 |
4 | 13 | 923.00 | 23 | 14.84 | 1562 | 533 | 2.88 / 377.72 | 2 | 4 |
5 | 13 | 315.48 | 23 | 14.96 | 710 | 244 | 3.12 / 377.96 | 2 | 3 |
6 | 13 | 28.00 | 23 | 15.03 | 298 | 103 | 3.22 / 378.06 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.00 | 251 | 621 | 3.85 / 378.68 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 31 | 14.98 | 413 | 192 | 0.19 / 371.11 | 2 | 2 |
2 | 7 | 2003.92 | 31 | 14.79 | 2963 | 1359 | 1.55 / 372.47 | 2 | 2 |
3 | 13 | 1724.12 | 23 | 14.74 | 2610 | 885 | 2.44 / 373.35 | 2 | 3 |
4 | 13 | 977.96 | 23 | 14.82 | 1632 | 556 | 2.99 / 373.91 | 2 | 3 |
5 | 13 | 245.00 | 23 | 14.99 | 606 | 209 | 3.20 / 374.12 | 2 | 3 |
6 | 13 | 22.52 | 23 | 15.03 | 290 | 100 | 3.30 / 374.22 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.01 | 251 | 622 | 3.92 / 374.84 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.36 | 30 | 14.99 | 421 | 189 | 0.19 / 367.13 | 2 | 2 |
2 | 7 | 2011.56 | 31 | 14.82 | 2967 | 1363 | 1.55 / 368.49 | 2 | 3 |
3 | 13 | 1611.20 | 23 | 14.78 | 2458 | 836 | 2.39 / 369.33 | 2 | 3 |
4 | 13 | 1012.12 | 23 | 14.83 | 1677 | 572 | 2.96 / 369.90 | 2 | 6 |
5 | 13 | 390.40 | 23 | 14.95 | 824 | 283 | 3.24 / 370.18 | 2 | 3 |
6 | 13 | 40.76 | 23 | 15.04 | 316 | 109 | 3.35 / 370.29 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.02 | 251 | 622 | 3.97 / 370.92 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 30 | 14.98 | 395 | 178 | 0.18 / 363.14 | 2 | 2 |
2 | 7 | 2006.40 | 30 | 14.81 | 2967 | 1318 | 1.50 / 364.45 | 2 | 2 |
3 | 13 | 1728.72 | 23 | 14.76 | 2610 | 886 | 2.38 / 365.34 | 2 | 3 |
4 | 13 | 1109.32 | 23 | 14.81 | 1809 | 616 | 3.00 / 365.96 | 2 | 3 |
5 | 13 | 340.60 | 23 | 14.98 | 747 | 257 | 3.26 / 366.21 | 2 | 3 |
6 | 13 | 38.12 | 23 | 15.05 | 312 | 108 | 3.36 / 366.32 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.03 | 250 | 620 | 3.98 / 366.94 | 2 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 30 | 14.99 | 395 | 178 | 0.18 / 359.28 | 2 | 2 |
2 | 7 | 2006.24 | 30 | 14.80 | 2972 | 1320 | 1.50 / 360.60 | 2 | 5 |
3 | 13 | 1610.16 | 23 | 14.77 | 2473 | 840 | 2.34 / 361.44 | 2 | 2 |
4 | 13 | 1018.36 | 23 | 14.81 | 1691 | 576 | 2.91 / 362.01 | 2 | 6 |
5 | 13 | 266.16 | 23 | 14.99 | 640 | 221 | 3.13 / 362.23 | 2 | 2 |
6 | 13 | 27.08 | 23 | 15.04 | 295 | 102 | 3.24 / 362.34 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.02 | 251 | 622 | 3.86 / 362.96 | 2 | 5 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 30 | 15.01 | 401 | 181 | 0.18 / 355.44 | 2 | 2 |
2 | 7 | 2008.84 | 30 | 14.81 | 2968 | 1319 | 1.50 / 356.76 | 2 | 4 |
3 | 13 | 1604.84 | 23 | 14.78 | 2454 | 834 | 2.33 / 357.59 | 2 | 3 |
4 | 13 | 995.80 | 23 | 14.83 | 1660 | 566 | 2.90 / 358.16 | 2 | 3 |
5 | 13 | 241.64 | 23 | 15.01 | 610 | 211 | 3.11 / 358.37 | 2 | 3 |
6 | 13 | 20.20 | 23 | 15.05 | 288 | 100 | 3.21 / 358.47 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.02 | 255 | 632 | 3.84 / 359.10 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 30 | 15.00 | 419 | 189 | 0.19 / 351.65 | 2 | 2 |
2 | 7 | 2009.68 | 31 | 14.80 | 2969 | 1362 | 1.55 / 353.01 | 2 | 3 |
3 | 13 | 1596.24 | 23 | 14.78 | 2451 | 833 | 2.38 / 353.85 | 2 | 3 |
4 | 13 | 999.48 | 23 | 14.83 | 1670 | 570 | 2.95 / 354.42 | 2 | 5 |
5 | 13 | 247.64 | 23 | 15.00 | 616 | 213 | 3.17 / 354.63 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.04 | 254 | 630 | 3.80 / 355.26 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 30 | 15.00 | 425 | 191 | 0.19 / 347.72 | 2 | 2 |
2 | 7 | 2010.00 | 31 | 14.82 | 2990 | 1374 | 1.56 / 349.10 | 2 | 3 |
3 | 13 | 1612.88 | 23 | 14.78 | 2473 | 841 | 2.41 / 349.94 | 2 | 3 |
4 | 13 | 1005.72 | 23 | 14.84 | 1678 | 573 | 2.98 / 350.51 | 2 | 4 |
5 | 13 | 251.80 | 23 | 15.01 | 626 | 216 | 3.19 / 350.73 | 2 | 2 |
6 | 13 | 17.44 | 23 | 15.07 | 285 | 99 | 3.29 / 350.82 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.03 | 257 | 637 | 3.93 / 351.46 | 2 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 30 | 15.00 | 418 | 188 | 0.19 / 343.93 | 2 | 2 |
2 | 7 | 2009.52 | 30 | 14.82 | 2980 | 1325 | 1.51 / 345.25 | 2 | 3 |
3 | 13 | 1605.52 | 23 | 14.78 | 2465 | 838 | 2.35 / 346.09 | 2 | 2 |
4 | 13 | 1021.40 | 23 | 14.82 | 1701 | 580 | 2.93 / 346.67 | 2 | 3 |
5 | 13 | 262.56 | 23 | 15.01 | 643 | 222 | 3.15 / 346.89 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.04 | 257 | 638 | 3.79 / 347.53 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 30 | 15.01 | 423 | 190 | 0.19 / 340.08 | 2 | 2 |
2 | 7 | 2003.84 | 31 | 14.83 | 2971 | 1366 | 1.56 / 341.44 | 2 | 3 |
3 | 13 | 1720.24 | 23 | 14.78 | 2615 | 889 | 2.45 / 342.33 | 2 | 2 |
4 | 13 | 971.60 | 23 | 14.86 | 1633 | 558 | 3.00 / 342.89 | 2 | 6 |
5 | 13 | 246.72 | 23 | 15.02 | 616 | 213 | 3.22 / 343.10 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.05 | 257 | 638 | 3.85 / 343.74 | 2 | 2 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 30 | 15.01 | 416 | 187 | 0.19 / 336.32 | 2 | 2 |
2 | 7 | 2006.36 | 30 | 14.82 | 2968 | 1320 | 1.51 / 337.64 | 2 | 2 |
3 | 13 | 1598.36 | 23 | 14.79 | 2448 | 833 | 2.34 / 338.47 | 2 | 3 |
4 | 13 | 999.72 | 23 | 14.84 | 1669 | 570 | 2.91 / 339.04 | 2 | 4 |
5 | 13 | 253.20 | 23 | 15.00 | 624 | 215 | 3.12 / 339.25 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.04 | 255 | 633 | 3.76 / 339.89 | 2 | 5 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 30 | 15.00 | 418 | 188 | 0.19 / 332.59 | 2 | 2 |
2 | 7 | 2003.16 | 30 | 14.83 | 2965 | 1319 | 1.51 / 333.90 | 2 | 3 |
3 | 13 | 1608.52 | 23 | 14.80 | 2461 | 838 | 2.34 / 334.74 | 2 | 3 |
4 | 13 | 897.20 | 23 | 14.88 | 1530 | 524 | 2.87 / 335.27 | 2 | 3 |
5 | 13 | 292.52 | 23 | 15.01 | 681 | 235 | 3.10 / 335.50 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.05 | 253 | 628 | 3.73 / 336.13 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 30 | 15.02 | 397 | 179 | 0.18 / 328.79 | 2 | 2 |
2 | 7 | 2010.96 | 30 | 14.82 | 2966 | 1319 | 1.50 / 330.11 | 2 | 3 |
3 | 13 | 1742.44 | 23 | 14.77 | 2629 | 893 | 2.39 / 331.00 | 2 | 4 |
4 | 13 | 984.24 | 23 | 14.84 | 1642 | 560 | 2.95 / 331.56 | 2 | 3 |
5 | 13 | 248.08 | 23 | 15.02 | 612 | 211 | 3.16 / 331.77 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.06 | 252 | 626 | 3.79 / 332.40 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 30 | 15.01 | 407 | 183 | 0.18 / 325.00 | 2 | 2 |
2 | 7 | 2006.84 | 31 | 14.83 | 2970 | 1365 | 1.55 / 326.37 | 2 | 3 |
3 | 13 | 1604.40 | 23 | 14.80 | 2453 | 835 | 2.38 / 327.20 | 2 | 3 |
4 | 13 | 1001.64 | 23 | 14.85 | 1670 | 570 | 2.95 / 327.77 | 2 | 3 |
5 | 13 | 246.72 | 23 | 15.03 | 607 | 210 | 3.16 / 327.98 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.06 | 251 | 624 | 3.79 / 328.61 | 2 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 30 | 15.03 | 417 | 188 | 0.19 / 321.14 | 2 | 2 |
2 | 7 | 2007.24 | 30 | 14.83 | 2966 | 1320 | 1.51 / 322.46 | 2 | 2 |
3 | 13 | 1606.04 | 23 | 14.78 | 2452 | 834 | 2.34 / 323.29 | 2 | 3 |
4 | 13 | 1008.68 | 23 | 14.85 | 1680 | 574 | 2.91 / 323.87 | 2 | 4 |
5 | 13 | 265.92 | 23 | 15.02 | 631 | 218 | 3.13 / 324.09 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.06 | 250 | 621 | 3.75 / 324.71 | 2 | 2 |
7 | 14 | 0.28 | 30 | 15.03 | 250 | 113 | 3.87 / 324.82 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 30 | 15.03 | 397 | 179 | 0.18 / 317.41 | 2 | 2 |
2 | 7 | 2006.08 | 30 | 14.82 | 2954 | 1313 | 1.49 / 318.72 | 2 | 5 |
3 | 13 | 1606.56 | 23 | 14.78 | 2452 | 834 | 2.33 / 319.55 | 2 | 3 |
4 | 13 | 999.60 | 23 | 14.84 | 1661 | 567 | 2.89 / 320.12 | 2 | 4 |
5 | 13 | 236.72 | 23 | 15.03 | 595 | 206 | 3.10 / 320.33 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.05 | 253 | 628 | 3.73 / 320.95 | 2 | 5 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 30 | 15.03 | 415 | 187 | 0.19 / 313.61 | 2 | 2 |
2 | 7 | 2002.64 | 30 | 14.83 | 2963 | 1318 | 1.51 / 314.93 | 2 | 3 |
3 | 13 | 1734.32 | 23 | 14.78 | 2622 | 891 | 2.40 / 315.82 | 2 | 3 |
4 | 13 | 986.64 | 23 | 14.86 | 1652 | 565 | 2.96 / 316.39 | 2 | 4 |
5 | 13 | 245.96 | 23 | 15.04 | 609 | 211 | 3.17 / 316.60 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.06 | 253 | 629 | 3.80 / 317.23 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 30 | 15.04 | 393 | 177 | 0.18 / 309.84 | 2 | 2 |
2 | 7 | 2007.68 | 30 | 14.84 | 2963 | 1319 | 1.50 / 311.15 | 2 | 4 |
3 | 13 | 1606.16 | 23 | 14.81 | 2461 | 838 | 2.33 / 311.99 | 2 | 3 |
4 | 13 | 1025.52 | 23 | 14.85 | 1703 | 582 | 2.92 / 312.57 | 2 | 3 |
5 | 13 | 269.64 | 23 | 15.02 | 646 | 223 | 3.14 / 312.80 | 2 | 2 |
6 | 8 | -0.12 | 165 | 15.07 | 253 | 629 | 3.77 / 313.43 | 2 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 30 | 15.05 | 399 | 180 | 0.18 / 306.01 | 2 | 2 |
2 | 7 | 2010.80 | 30 | 14.82 | 2973 | 1322 | 1.50 / 307.34 | 2 | 2 |
3 | 13 | 1753.24 | 23 | 14.77 | 2652 | 901 | 2.40 / 308.24 | 2 | 3 |
4 | 13 | 1000.84 | 23 | 14.85 | 1670 | 570 | 2.97 / 308.81 | 2 | 4 |
5 | 13 | 269.68 | 23 | 15.04 | 645 | 223 | 3.20 / 309.03 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.07 | 252 | 627 | 3.82 / 309.66 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 30 | 15.03 | 413 | 186 | 0.19 / 302.19 | 2 | 2 |
2 | 7 | 2009.84 | 30 | 14.84 | 2980 | 1327 | 1.51 / 303.52 | 2 | 2 |
3 | 13 | 1744.60 | 23 | 14.78 | 2636 | 896 | 2.41 / 304.42 | 2 | 2 |
4 | 13 | 986.40 | 23 | 14.88 | 1655 | 566 | 2.98 / 304.98 | 2 | 5 |
5 | 13 | 249.72 | 23 | 15.05 | 617 | 214 | 3.19 / 305.20 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.08 | 256 | 637 | 3.83 / 305.83 | 2 | 3 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 30 | 15.05 | 399 | 180 | 0.18 / 298.35 | 2 | 2 |
2 | 7 | 2008.68 | 31 | 14.84 | 2981 | 1371 | 1.55 / 299.72 | 2 | 2 |
3 | 13 | 1597.24 | 23 | 14.80 | 2447 | 833 | 2.38 / 300.55 | 2 | 3 |
4 | 13 | 903.44 | 23 | 14.88 | 1538 | 526 | 2.91 / 301.08 | 2 | 4 |
5 | 13 | 200.16 | 23 | 15.06 | 545 | 189 | 3.10 / 301.27 | 2 | 2 |
6 | 13 | 39.88 | 23 | 15.09 | 316 | 110 | 3.21 / 301.38 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.07 | 254 | 632 | 3.84 / 302.01 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 30 | 15.06 | 399 | 180 | 0.18 / 294.55 | 2 | 2 |
2 | 7 | 2010.92 | 30 | 14.85 | 2985 | 1330 | 1.51 / 295.88 | 2 | 2 |
3 | 13 | 1615.44 | 23 | 14.81 | 2473 | 842 | 2.35 / 296.72 | 2 | 3 |
4 | 13 | 1030.92 | 23 | 14.86 | 1704 | 582 | 2.93 / 297.31 | 2 | 3 |
5 | 13 | 273.48 | 23 | 15.05 | 654 | 226 | 3.16 / 297.53 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.09 | 255 | 635 | 3.80 / 298.17 | 2 | 2 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 30 | 15.06 | 418 | 189 | 0.19 / 290.71 | 2 | 2 |
2 | 7 | 2005.04 | 30 | 14.85 | 2959 | 1318 | 1.51 / 292.03 | 2 | 3 |
3 | 13 | 1592.00 | 23 | 14.80 | 2447 | 833 | 2.34 / 292.86 | 2 | 3 |
4 | 13 | 994.68 | 23 | 14.88 | 1667 | 571 | 2.91 / 293.43 | 2 | 3 |
5 | 13 | 241.48 | 23 | 15.06 | 603 | 209 | 3.12 / 293.64 | 2 | 2 |
6 | 13 | 22.92 | 23 | 15.12 | 289 | 101 | 3.22 / 293.74 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.09 | 252 | 627 | 3.85 / 294.37 | 2 | 4 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 30 | 15.05 | 418 | 189 | 0.19 / 286.87 | 2 | 2 |
2 | 7 | 2007.72 | 30 | 14.85 | 2974 | 1325 | 1.51 / 288.19 | 2 | 2 |
3 | 13 | 1592.84 | 23 | 14.81 | 2439 | 831 | 2.34 / 289.02 | 2 | 2 |
4 | 13 | 996.44 | 23 | 14.88 | 1665 | 570 | 2.91 / 289.59 | 2 | 3 |
5 | 13 | 238.20 | 23 | 15.06 | 597 | 207 | 3.12 / 289.80 | 2 | 3 |
6 | 13 | 20.64 | 23 | 15.12 | 284 | 99 | 3.22 / 289.90 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.09 | 252 | 627 | 3.85 / 290.52 | 2 | 5 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 30 | 15.07 | 394 | 178 | 0.18 / 282.90 | 2 | 2 |
2 | 7 | 2008.16 | 31 | 14.86 | 2972 | 1369 | 1.55 / 284.27 | 2 | 4 |
3 | 13 | 1744.08 | 23 | 14.79 | 2639 | 898 | 2.44 / 285.17 | 2 | 3 |
4 | 13 | 994.88 | 23 | 14.88 | 1657 | 567 | 3.01 / 285.74 | 2 | 4 |
5 | 13 | 261.24 | 23 | 15.05 | 633 | 219 | 3.23 / 285.96 | 2 | 3 |
6 | 13 | 23.52 | 23 | 15.11 | 287 | 100 | 3.33 / 286.06 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.08 | 250 | 622 | 3.95 / 286.68 | 2 | 5 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 30 | 15.06 | 399 | 180 | 0.18 / 279.07 | 2 | 2 |
2 | 7 | 2003.76 | 31 | 14.85 | 2975 | 1370 | 1.55 / 280.44 | 2 | 2 |
3 | 13 | 1742.72 | 23 | 14.78 | 2633 | 895 | 2.44 / 281.34 | 2 | 3 |
4 | 13 | 973.12 | 23 | 14.88 | 1633 | 559 | 3.00 / 281.90 | 2 | 3 |
5 | 13 | 220.52 | 23 | 15.07 | 574 | 199 | 3.20 / 282.10 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.10 | 252 | 628 | 3.83 / 282.72 | 2 | 6 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 30 | 15.05 | 404 | 182 | 0.18 / 275.18 | 2 | 2 |
2 | 7 | 2003.64 | 30 | 14.85 | 2967 | 1322 | 1.50 / 276.51 | 2 | 3 |
3 | 13 | 1612.44 | 23 | 14.80 | 2472 | 841 | 2.35 / 277.35 | 2 | 4 |
4 | 13 | 1016.40 | 23 | 14.86 | 1692 | 578 | 2.92 / 277.93 | 2 | 4 |
5 | 13 | 248.36 | 23 | 15.07 | 623 | 216 | 3.14 / 278.14 | 2 | 2 |
6 | 13 | 40.28 | 23 | 15.12 | 321 | 112 | 3.25 / 278.25 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.09 | 257 | 640 | 3.89 / 278.89 | 2 | 4 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 30 | 15.07 | 419 | 189 | 0.19 / 271.37 | 2 | 2 |
2 | 7 | 2004.68 | 30 | 14.83 | 2967 | 1320 | 1.51 / 272.69 | 2 | 2 |
3 | 13 | 1586.56 | 23 | 14.81 | 2436 | 830 | 2.34 / 273.52 | 2 | 4 |
4 | 13 | 878.40 | 23 | 14.92 | 1508 | 517 | 2.86 / 274.03 | 2 | 4 |
5 | 13 | 270.72 | 23 | 15.06 | 655 | 227 | 3.08 / 274.26 | 2 | 3 |
6 | 13 | 23.28 | 23 | 15.12 | 292 | 102 | 3.19 / 274.36 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.09 | 257 | 640 | 3.83 / 275.00 | 2 | 4 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 30 | 15.08 | 419 | 190 | 0.19 / 267.56 | 2 | 2 |
2 | 7 | 2006.52 | 30 | 14.84 | 2958 | 1317 | 1.51 / 268.88 | 2 | 3 |
3 | 13 | 1580.88 | 23 | 14.81 | 2420 | 824 | 2.33 / 269.70 | 2 | 3 |
4 | 13 | 864.08 | 23 | 14.91 | 1486 | 510 | 2.84 / 270.21 | 2 | 4 |
5 | 13 | 246.24 | 23 | 15.07 | 616 | 214 | 3.05 / 270.43 | 2 | 2 |
6 | 13 | 39.36 | 23 | 15.12 | 322 | 112 | 3.17 / 270.54 | 2 | 3 |
7 | 8 | 0.32 | 165 | 15.09 | 256 | 637 | 3.80 / 271.18 | 2 | 4 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.68 | 30 | 15.07 | 400 | 181 | 0.18 / 263.67 | 2 | 2 |
2 | 7 | 2003.40 | 30 | 14.86 | 2969 | 1324 | 1.50 / 264.99 | 2 | 2 |
3 | 13 | 1722.92 | 23 | 14.81 | 2610 | 889 | 2.39 / 265.88 | 2 | 2 |
4 | 13 | 955.24 | 23 | 14.90 | 1606 | 550 | 2.94 / 266.43 | 2 | 4 |
5 | 13 | 207.36 | 23 | 15.09 | 567 | 197 | 3.14 / 266.63 | 2 | 3 |
6 | 13 | 37.80 | 23 | 15.12 | 318 | 111 | 3.25 / 266.74 | 2 | 2 |
7 | 8 | -0.08 | 165 | 15.10 | 255 | 635 | 3.89 / 267.37 | 2 | 3 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 30 | 15.07 | 389 | 176 | 0.18 / 259.63 | 2 | 2 |
2 | 7 | 2011.76 | 30 | 14.84 | 2978 | 1326 | 1.50 / 260.96 | 2 | 3 |
3 | 13 | 1750.88 | 23 | 14.78 | 2642 | 898 | 2.40 / 261.85 | 2 | 3 |
4 | 13 | 984.08 | 23 | 14.88 | 1649 | 564 | 2.96 / 262.42 | 2 | 3 |
5 | 13 | 230.60 | 23 | 15.08 | 593 | 206 | 3.17 / 262.62 | 2 | 2 |
6 | 13 | 46.08 | 23 | 15.13 | 330 | 115 | 3.28 / 262.74 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.10 | 254 | 633 | 3.92 / 263.37 | 2 | 5 |
8 | 14 | 0.04 | 30 | 15.09 | 254 | 115 | 4.03 / 263.49 | 2 | 12 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 30 | 15.08 | 396 | 179 | 0.18 / 255.71 | 2 | 2 |
2 | 7 | 2006.20 | 30 | 14.86 | 2968 | 1323 | 1.50 / 257.03 | 2 | 3 |
3 | 13 | 1615.16 | 23 | 14.82 | 2465 | 840 | 2.34 / 257.87 | 2 | 2 |
4 | 13 | 909.48 | 23 | 14.91 | 1553 | 533 | 2.88 / 258.40 | 2 | 3 |
5 | 13 | 207.36 | 23 | 15.10 | 558 | 194 | 3.07 / 258.60 | 2 | 2 |
6 | 13 | 41.08 | 23 | 15.13 | 320 | 111 | 3.18 / 258.71 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.11 | 254 | 633 | 3.81 / 259.34 | 2 | 9 |
8 | 14 | 0.12 | 30 | 15.09 | 254 | 115 | 3.93 / 259.45 | 2 | 4 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 30 | 15.09 | 416 | 188 | 0.19 / 251.86 | 2 | 2 |
2 | 7 | 2009.12 | 30 | 14.85 | 2976 | 1326 | 1.51 / 253.18 | 2 | 4 |
3 | 13 | 1602.44 | 23 | 14.80 | 2454 | 835 | 2.35 / 254.02 | 2 | 4 |
4 | 13 | 989.40 | 23 | 14.89 | 1658 | 568 | 2.92 / 254.58 | 2 | 3 |
5 | 13 | 233.20 | 23 | 15.09 | 597 | 207 | 3.12 / 254.79 | 2 | 2 |
6 | 13 | 26.40 | 23 | 15.15 | 299 | 104 | 3.23 / 254.90 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.11 | 253 | 631 | 3.86 / 255.53 | 2 | 9 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 30 | 15.09 | 415 | 188 | 0.19 / 247.80 | 2 | 2 |
2 | 7 | 2004.72 | 31 | 14.86 | 2975 | 1370 | 1.56 / 249.17 | 2 | 5 |
3 | 13 | 1727.40 | 23 | 14.80 | 2609 | 888 | 2.45 / 250.06 | 2 | 3 |
4 | 13 | 951.56 | 23 | 14.90 | 1598 | 548 | 2.99 / 250.61 | 2 | 3 |
5 | 13 | 207.72 | 23 | 15.10 | 562 | 195 | 3.19 / 250.80 | 2 | 2 |
6 | 13 | 43.32 | 23 | 15.14 | 323 | 112 | 3.30 / 250.92 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.12 | 255 | 636 | 3.94 / 251.55 | 2 | 12 |
8 | 14 | 0.04 | 30 | 15.10 | 254 | 115 | 4.05 / 251.67 | 2 | 4 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 30 | 15.09 | 401 | 182 | 0.18 / 243.95 | 2 | 2 |
2 | 7 | 2002.64 | 30 | 14.84 | 2972 | 1323 | 1.50 / 245.28 | 2 | 2 |
3 | 13 | 1591.80 | 23 | 14.82 | 2441 | 832 | 2.34 / 246.11 | 2 | 3 |
4 | 13 | 892.60 | 23 | 14.92 | 1529 | 525 | 2.86 / 246.63 | 2 | 3 |
5 | 13 | 285.52 | 23 | 15.07 | 676 | 234 | 3.10 / 246.87 | 2 | 3 |
6 | 13 | 34.20 | 23 | 15.14 | 312 | 109 | 3.20 / 246.98 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.12 | 256 | 639 | 3.84 / 247.61 | 2 | 8 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 30 | 15.09 | 392 | 177 | 0.18 / 240.03 | 2 | 2 |
2 | 7 | 2004.20 | 30 | 14.86 | 2960 | 1320 | 1.50 / 241.35 | 2 | 3 |
3 | 13 | 1728.96 | 23 | 14.81 | 2626 | 894 | 2.39 / 242.24 | 2 | 3 |
4 | 13 | 990.32 | 23 | 14.91 | 1658 | 569 | 2.96 / 242.81 | 2 | 3 |
5 | 13 | 244.12 | 23 | 15.11 | 611 | 212 | 3.17 / 243.02 | 2 | 2 |
6 | 13 | 38.80 | 23 | 15.14 | 318 | 111 | 3.28 / 243.13 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.12 | 256 | 639 | 3.92 / 243.77 | 2 | 4 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 30 | 15.09 | 398 | 180 | 0.18 / 236.17 | 2 | 2 |
2 | 7 | 2003.96 | 30 | 14.85 | 2975 | 1325 | 1.51 / 237.49 | 2 | 3 |
3 | 13 | 1599.92 | 23 | 14.82 | 2458 | 838 | 2.34 / 238.33 | 2 | 2 |
4 | 13 | 998.00 | 23 | 14.90 | 1664 | 570 | 2.91 / 238.90 | 2 | 3 |
5 | 13 | 249.76 | 23 | 15.10 | 620 | 215 | 3.13 / 239.11 | 2 | 3 |
6 | 13 | 25.60 | 23 | 15.15 | 295 | 103 | 3.23 / 239.22 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.13 | 253 | 632 | 3.86 / 239.85 | 2 | 6 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 30 | 15.11 | 389 | 176 | 0.18 / 232.24 | 2 | 2 |
2 | 7 | 2004.32 | 30 | 14.88 | 2971 | 1326 | 1.50 / 233.57 | 2 | 2 |
3 | 13 | 1729.48 | 23 | 14.81 | 2609 | 889 | 2.39 / 234.46 | 2 | 3 |
4 | 13 | 974.12 | 23 | 14.90 | 1634 | 560 | 2.95 / 235.02 | 2 | 3 |
5 | 13 | 249.12 | 23 | 15.10 | 620 | 215 | 3.17 / 235.23 | 2 | 2 |
6 | 13 | 46.04 | 23 | 15.15 | 330 | 115 | 3.28 / 235.35 | 2 | 5 |
7 | 8 | 0.12 | 165 | 15.12 | 256 | 639 | 3.92 / 235.99 | 2 | 3 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 30 | 15.10 | 416 | 188 | 0.19 / 228.43 | 2 | 2 |
2 | 7 | 2007.84 | 30 | 14.86 | 2969 | 1324 | 1.51 / 229.75 | 2 | 3 |
3 | 13 | 1603.24 | 23 | 14.83 | 2452 | 836 | 2.35 / 230.59 | 2 | 3 |
4 | 13 | 1005.04 | 23 | 14.90 | 1674 | 574 | 2.92 / 231.16 | 2 | 3 |
5 | 13 | 151.60 | 23 | 15.13 | 477 | 166 | 3.09 / 231.33 | 2 | 2 |
6 | 13 | 33.12 | 23 | 15.15 | 307 | 107 | 3.20 / 231.44 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.13 | 252 | 629 | 3.82 / 232.07 | 2 | 3 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 30 | 15.11 | 394 | 179 | 0.18 / 224.57 | 2 | 2 |
2 | 7 | 2003.60 | 30 | 14.88 | 2970 | 1326 | 1.50 / 225.90 | 2 | 2 |
3 | 13 | 1605.68 | 23 | 14.85 | 2458 | 840 | 2.34 / 226.74 | 2 | 3 |
4 | 13 | 990.40 | 23 | 14.92 | 1653 | 567 | 2.91 / 227.31 | 2 | 3 |
5 | 13 | 218.96 | 23 | 15.13 | 576 | 200 | 3.11 / 227.51 | 2 | 2 |
6 | 13 | 31.08 | 23 | 15.17 | 301 | 105 | 3.22 / 227.61 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.14 | 252 | 630 | 3.85 / 228.24 | 2 | 3 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 30 | 15.10 | 418 | 189 | 0.19 / 220.71 | 2 | 2 |
2 | 7 | 2005.88 | 30 | 14.88 | 2970 | 1326 | 1.52 / 222.04 | 2 | 3 |
3 | 13 | 1608.60 | 23 | 14.84 | 2455 | 838 | 2.35 / 222.88 | 2 | 2 |
4 | 13 | 1007.56 | 23 | 14.92 | 1677 | 575 | 2.93 / 223.45 | 2 | 3 |
5 | 13 | 237.80 | 23 | 15.12 | 599 | 208 | 3.14 / 223.66 | 2 | 3 |
6 | 13 | 20.48 | 23 | 15.17 | 289 | 101 | 3.24 / 223.76 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.14 | 254 | 635 | 3.87 / 224.40 | 2 | 4 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 30 | 15.12 | 415 | 188 | 0.19 / 216.81 | 2 | 2 |
2 | 7 | 2004.96 | 30 | 14.88 | 2967 | 1324 | 1.51 / 218.13 | 2 | 2 |
3 | 13 | 1725.80 | 23 | 14.83 | 2614 | 892 | 2.40 / 219.02 | 2 | 5 |
4 | 13 | 969.60 | 23 | 14.93 | 1625 | 558 | 2.96 / 219.58 | 2 | 4 |
5 | 13 | 219.00 | 23 | 15.13 | 573 | 199 | 3.16 / 219.78 | 2 | 3 |
6 | 13 | 19.80 | 23 | 15.17 | 289 | 101 | 3.26 / 219.88 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.14 | 257 | 642 | 3.90 / 220.52 | 2 | 6 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 30 | 15.13 | 408 | 185 | 0.19 / 213.04 | 2 | 2 |
2 | 7 | 2006.32 | 30 | 14.87 | 2972 | 1326 | 1.51 / 214.36 | 2 | 2 |
3 | 13 | 1608.32 | 23 | 14.83 | 2463 | 840 | 2.35 / 215.20 | 2 | 3 |
4 | 13 | 876.72 | 23 | 14.95 | 1502 | 516 | 2.87 / 215.72 | 2 | 4 |
5 | 13 | 153.16 | 23 | 15.15 | 477 | 166 | 3.03 / 215.88 | 2 | 2 |
6 | 13 | 17.36 | 23 | 15.17 | 283 | 99 | 3.13 / 215.98 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.15 | 254 | 635 | 3.77 / 216.62 | 2 | 3 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 30 | 15.11 | 424 | 192 | 0.19 / 209.08 | 2 | 2 |
2 | 7 | 2009.92 | 31 | 14.88 | 2978 | 1374 | 1.57 / 210.45 | 2 | 4 |
3 | 13 | 1733.32 | 23 | 14.83 | 2621 | 894 | 2.46 / 211.35 | 2 | 3 |
4 | 13 | 979.84 | 23 | 14.93 | 1641 | 564 | 3.02 / 211.91 | 2 | 3 |
5 | 13 | 219.72 | 23 | 15.15 | 578 | 201 | 3.22 / 212.11 | 2 | 3 |
6 | 13 | 21.68 | 23 | 15.19 | 291 | 102 | 3.33 / 212.21 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.16 | 255 | 638 | 3.96 / 212.85 | 2 | 2 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 30 | 15.12 | 425 | 193 | 0.19 / 205.17 | 2 | 2 |
2 | 7 | 2003.48 | 30 | 14.87 | 2974 | 1327 | 1.52 / 206.50 | 2 | 2 |
3 | 13 | 1606.52 | 23 | 14.84 | 2462 | 840 | 2.36 / 207.34 | 2 | 3 |
4 | 13 | 1005.72 | 23 | 14.92 | 1678 | 576 | 2.94 / 207.92 | 2 | 3 |
5 | 13 | 237.00 | 23 | 15.14 | 607 | 211 | 3.15 / 208.13 | 2 | 3 |
6 | 13 | 19.24 | 23 | 15.19 | 295 | 103 | 3.25 / 208.23 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.15 | 262 | 655 | 3.91 / 208.89 | 2 | 3 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 30 | 15.14 | 421 | 191 | 0.19 / 201.30 | 2 | 2 |
2 | 7 | 2002.96 | 30 | 14.88 | 2963 | 1323 | 1.51 / 202.63 | 2 | 4 |
3 | 13 | 1578.92 | 23 | 14.86 | 2421 | 827 | 2.34 / 203.45 | 2 | 3 |
4 | 13 | 981.80 | 23 | 14.93 | 1650 | 567 | 2.91 / 204.02 | 2 | 4 |
5 | 13 | 230.00 | 23 | 15.13 | 602 | 209 | 3.12 / 204.23 | 2 | 3 |
6 | 13 | 16.84 | 23 | 15.18 | 290 | 101 | 3.22 / 204.33 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.15 | 260 | 650 | 3.87 / 204.98 | 2 | 5 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 30 | 15.14 | 428 | 194 | 0.19 / 197.51 | 2 | 2 |
2 | 7 | 2003.08 | 30 | 14.89 | 2978 | 1330 | 1.52 / 198.84 | 2 | 5 |
3 | 13 | 1607.44 | 23 | 14.84 | 2467 | 842 | 2.37 / 199.68 | 2 | 3 |
4 | 13 | 996.28 | 23 | 14.94 | 1663 | 571 | 2.94 / 200.25 | 2 | 4 |
5 | 13 | 228.08 | 23 | 15.14 | 592 | 206 | 3.14 / 200.46 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.17 | 261 | 653 | 3.80 / 201.11 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 30 | 15.14 | 422 | 192 | 0.19 / 193.66 | 2 | 2 |
2 | 7 | 2010.08 | 31 | 14.89 | 2975 | 1373 | 1.56 / 195.03 | 2 | 3 |
3 | 13 | 1602.44 | 23 | 14.87 | 2455 | 840 | 2.40 / 195.87 | 2 | 3 |
4 | 13 | 994.12 | 23 | 14.94 | 1665 | 572 | 2.98 / 196.45 | 2 | 4 |
5 | 13 | 241.08 | 23 | 15.14 | 613 | 213 | 3.19 / 196.66 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.18 | 262 | 656 | 3.85 / 197.32 | 2 | 3 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 30 | 15.14 | 416 | 189 | 0.19 / 189.87 | 2 | 2 |
2 | 7 | 2005.68 | 30 | 14.88 | 2962 | 1322 | 1.51 / 191.19 | 2 | 2 |
3 | 13 | 1603.04 | 23 | 14.85 | 2463 | 841 | 2.35 / 192.04 | 2 | 2 |
4 | 13 | 1001.84 | 23 | 14.93 | 1673 | 574 | 2.93 / 192.61 | 2 | 4 |
5 | 13 | 225.32 | 23 | 15.15 | 587 | 205 | 3.13 / 192.81 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.19 | 261 | 654 | 3.79 / 193.47 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 30 | 15.15 | 400 | 182 | 0.18 / 186.09 | 2 | 2 |
2 | 7 | 2004.52 | 30 | 14.89 | 2976 | 1329 | 1.51 / 187.42 | 2 | 2 |
3 | 13 | 1578.68 | 23 | 14.88 | 2431 | 832 | 2.34 / 188.25 | 2 | 3 |
4 | 13 | 999.08 | 23 | 14.94 | 1668 | 573 | 2.92 / 188.82 | 2 | 3 |
5 | 13 | 229.76 | 23 | 15.15 | 595 | 207 | 3.12 / 189.03 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.18 | 261 | 654 | 3.78 / 189.68 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 30 | 15.15 | 399 | 181 | 0.18 / 182.31 | 2 | 2 |
2 | 7 | 2010.56 | 30 | 14.89 | 2975 | 1329 | 1.51 / 183.63 | 2 | 2 |
3 | 13 | 1607.68 | 23 | 14.85 | 2460 | 840 | 2.35 / 184.47 | 2 | 3 |
4 | 13 | 1010.08 | 23 | 14.93 | 1685 | 579 | 2.93 / 185.05 | 2 | 3 |
5 | 13 | 231.84 | 23 | 15.15 | 593 | 207 | 3.14 / 185.26 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.18 | 258 | 646 | 3.78 / 185.91 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.24 | 30 | 15.15 | 427 | 194 | 0.19 / 178.50 | 2 | 2 |
2 | 7 | 2006.56 | 30 | 14.90 | 2968 | 1327 | 1.52 / 179.82 | 2 | 3 |
3 | 13 | 1731.64 | 23 | 14.84 | 2615 | 893 | 2.41 / 180.72 | 2 | 5 |
4 | 13 | 972.80 | 23 | 14.95 | 1636 | 563 | 2.98 / 181.28 | 2 | 3 |
5 | 13 | 221.52 | 23 | 15.16 | 579 | 202 | 3.18 / 181.48 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.19 | 257 | 644 | 3.82 / 182.12 | 2 | 2 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 30 | 15.16 | 425 | 193 | 0.19 / 174.72 | 2 | 2 |
2 | 7 | 2008.60 | 30 | 14.89 | 2980 | 1331 | 1.52 / 176.06 | 2 | 5 |
3 | 13 | 1600.00 | 23 | 14.87 | 2451 | 838 | 2.36 / 176.89 | 2 | 3 |
4 | 13 | 890.56 | 23 | 14.97 | 1526 | 525 | 2.89 / 177.42 | 2 | 4 |
5 | 13 | 273.44 | 23 | 15.14 | 658 | 229 | 3.12 / 177.65 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.18 | 261 | 654 | 3.77 / 178.30 | 2 | 3 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 29 | 15.16 | 420 | 185 | 0.18 / 170.90 | 2 | 2 |
2 | 7 | 2004.80 | 30 | 14.90 | 2966 | 1326 | 1.51 / 172.23 | 2 | 3 |
3 | 13 | 1732.68 | 23 | 14.84 | 2616 | 893 | 2.40 / 173.12 | 2 | 4 |
4 | 13 | 974.68 | 23 | 14.95 | 1643 | 565 | 2.97 / 173.69 | 2 | 4 |
5 | 13 | 215.56 | 23 | 15.16 | 570 | 199 | 3.17 / 173.88 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.20 | 258 | 647 | 3.81 / 174.53 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 29 | 15.16 | 422 | 186 | 0.19 / 166.98 | 2 | 2 |
2 | 7 | 2004.76 | 30 | 14.90 | 2977 | 1331 | 1.52 / 168.31 | 2 | 3 |
3 | 13 | 1728.56 | 23 | 14.86 | 2615 | 894 | 2.41 / 169.21 | 2 | 2 |
4 | 13 | 964.16 | 23 | 14.97 | 1616 | 556 | 2.97 / 169.76 | 2 | 4 |
5 | 13 | 222.52 | 23 | 15.18 | 585 | 204 | 3.17 / 169.97 | 2 | 3 |
6 | 13 | 17.16 | 23 | 15.24 | 289 | 101 | 3.27 / 170.07 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.20 | 259 | 650 | 3.92 / 170.72 | 2 | 5 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 29 | 15.17 | 411 | 181 | 0.18 / 163.29 | 2 | 2 |
2 | 7 | 2010.20 | 30 | 14.90 | 2979 | 1332 | 1.51 / 164.62 | 2 | 4 |
3 | 13 | 1493.44 | 23 | 14.89 | 2316 | 793 | 2.31 / 165.41 | 2 | 3 |
4 | 13 | 938.52 | 23 | 14.98 | 1586 | 546 | 2.85 / 165.96 | 2 | 4 |
5 | 13 | 189.60 | 23 | 15.19 | 542 | 189 | 3.04 / 166.15 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.20 | 258 | 647 | 3.69 / 166.80 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 30 | 15.17 | 400 | 182 | 0.18 / 159.55 | 2 | 2 |
2 | 7 | 2004.28 | 30 | 14.91 | 2975 | 1331 | 1.51 / 160.88 | 2 | 2 |
3 | 13 | 1578.80 | 23 | 14.87 | 2428 | 830 | 2.34 / 161.71 | 2 | 2 |
4 | 13 | 868.00 | 23 | 15.01 | 1496 | 516 | 2.86 / 162.23 | 2 | 3 |
5 | 13 | 255.68 | 23 | 15.18 | 634 | 221 | 3.08 / 162.45 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.21 | 263 | 660 | 3.74 / 163.11 | 2 | 2 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 30 | 15.17 | 425 | 193 | 0.19 / 155.81 | 2 | 2 |
2 | 7 | 2001.80 | 30 | 14.91 | 2958 | 1323 | 1.52 / 157.13 | 2 | 2 |
3 | 13 | 1568.16 | 23 | 14.90 | 2409 | 826 | 2.34 / 157.96 | 2 | 3 |
4 | 13 | 962.08 | 23 | 14.99 | 1620 | 559 | 2.90 / 158.52 | 2 | 4 |
5 | 13 | 212.76 | 23 | 15.19 | 571 | 199 | 3.10 / 158.72 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.21 | 259 | 650 | 3.75 / 159.37 | 2 | 3 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 30 | 15.17 | 425 | 193 | 0.19 / 151.99 | 2 | 2 |
2 | 7 | 2012.12 | 30 | 14.91 | 2986 | 1336 | 1.53 / 153.33 | 2 | 4 |
3 | 13 | 1619.60 | 23 | 14.88 | 2475 | 847 | 2.38 / 154.17 | 2 | 3 |
4 | 13 | 1005.64 | 23 | 14.97 | 1681 | 579 | 2.95 / 154.75 | 2 | 4 |
5 | 13 | 226.40 | 23 | 15.19 | 595 | 208 | 3.16 / 154.96 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.20 | 262 | 657 | 3.82 / 155.62 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 30 | 15.18 | 417 | 190 | 0.19 / 148.21 | 2 | 2 |
2 | 7 | 2002.48 | 30 | 14.91 | 2964 | 1326 | 1.52 / 149.53 | 2 | 2 |
3 | 13 | 1589.52 | 23 | 14.89 | 2439 | 835 | 2.35 / 150.37 | 2 | 3 |
4 | 13 | 986.76 | 23 | 14.99 | 1654 | 570 | 2.92 / 150.94 | 2 | 3 |
5 | 13 | 219.60 | 23 | 15.19 | 584 | 204 | 3.13 / 151.14 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.21 | 261 | 655 | 3.78 / 151.80 | 2 | 2 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 30 | 15.18 | 428 | 195 | 0.19 / 144.29 | 2 | 2 |
2 | 7 | 2011.04 | 31 | 14.91 | 2984 | 1379 | 1.57 / 145.67 | 2 | 3 |
3 | 13 | 1753.64 | 23 | 14.86 | 2649 | 905 | 2.48 / 146.58 | 2 | 3 |
4 | 13 | 980.44 | 23 | 14.98 | 1647 | 567 | 3.05 / 147.15 | 2 | 4 |
5 | 13 | 242.92 | 23 | 15.19 | 615 | 215 | 3.26 / 147.36 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.22 | 261 | 655 | 3.92 / 148.02 | 2 | 4 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 30 | 15.18 | 395 | 180 | 0.18 / 140.57 | 2 | 2 |
2 | 7 | 2006.92 | 30 | 14.92 | 2977 | 1333 | 1.51 / 141.90 | 2 | 3 |
3 | 13 | 1594.08 | 23 | 14.88 | 2446 | 837 | 2.35 / 142.74 | 2 | 3 |
4 | 13 | 893.68 | 23 | 15.00 | 1532 | 529 | 2.88 / 143.27 | 2 | 3 |
5 | 13 | 162.32 | 23 | 15.20 | 500 | 175 | 3.05 / 143.44 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.21 | 261 | 655 | 3.71 / 144.10 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 30 | 15.17 | 395 | 180 | 0.18 / 136.68 | 2 | 2 |
2 | 7 | 2007.28 | 30 | 14.93 | 2982 | 1336 | 1.52 / 138.02 | 2 | 2 |
3 | 13 | 1581.12 | 23 | 14.90 | 2434 | 834 | 2.35 / 138.85 | 2 | 2 |
4 | 13 | 999.04 | 23 | 14.99 | 1676 | 578 | 2.93 / 139.43 | 2 | 4 |
5 | 13 | 221.08 | 23 | 15.20 | 588 | 206 | 3.13 / 139.64 | 2 | 2 |
6 | 13 | 16.44 | 23 | 15.24 | 287 | 101 | 3.23 / 139.74 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.21 | 261 | 655 | 3.89 / 140.39 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 30 | 15.19 | 422 | 192 | 0.19 / 132.79 | 2 | 2 |
2 | 7 | 2006.96 | 30 | 14.93 | 2973 | 1332 | 1.52 / 134.12 | 2 | 3 |
3 | 13 | 1592.20 | 23 | 14.90 | 2451 | 840 | 2.36 / 134.96 | 2 | 3 |
4 | 13 | 987.16 | 23 | 14.99 | 1659 | 572 | 2.94 / 135.53 | 2 | 5 |
5 | 13 | 216.84 | 23 | 15.20 | 577 | 202 | 3.14 / 135.74 | 2 | 2 |
6 | 13 | 38.72 | 23 | 15.24 | 322 | 113 | 3.25 / 135.85 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.22 | 260 | 653 | 3.90 / 136.50 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 30 | 15.19 | 401 | 183 | 0.18 / 129.10 | 2 | 2 |
2 | 7 | 2002.44 | 30 | 14.92 | 2961 | 1325 | 1.51 / 130.43 | 2 | 3 |
3 | 13 | 1596.92 | 23 | 14.90 | 2446 | 838 | 2.35 / 131.27 | 2 | 2 |
4 | 13 | 870.32 | 23 | 15.03 | 1501 | 519 | 2.87 / 131.79 | 2 | 4 |
5 | 13 | 151.20 | 23 | 15.22 | 479 | 168 | 3.03 / 131.95 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.22 | 257 | 645 | 3.68 / 132.60 | 2 | 3 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 29 | 15.19 | 421 | 185 | 0.19 / 125.23 | 2 | 2 |
2 | 7 | 2005.08 | 30 | 14.91 | 2964 | 1326 | 1.51 / 126.56 | 2 | 3 |
3 | 13 | 1588.32 | 23 | 14.89 | 2437 | 835 | 2.35 / 127.39 | 2 | 3 |
4 | 13 | 980.20 | 23 | 14.99 | 1645 | 567 | 2.91 / 127.96 | 2 | 4 |
5 | 13 | 211.80 | 23 | 15.19 | 568 | 198 | 3.11 / 128.16 | 2 | 3 |
6 | 8 | 0.40 | 165 | 15.22 | 257 | 645 | 3.76 / 128.80 | 2 | 4 |
7 | 14 | 0.40 | 30 | 15.20 | 257 | 117 | 3.87 / 128.92 | 2 | 3 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 29 | 15.19 | 416 | 183 | 0.18 / 121.36 | 2 | 2 |
2 | 7 | 2003.32 | 30 | 14.93 | 2965 | 1328 | 1.51 / 122.69 | 2 | 2 |
3 | 13 | 1589.68 | 23 | 14.90 | 2436 | 835 | 2.35 / 123.53 | 2 | 3 |
4 | 13 | 977.16 | 23 | 15.00 | 1642 | 566 | 2.91 / 124.09 | 2 | 4 |
5 | 13 | 213.44 | 23 | 15.20 | 567 | 198 | 3.11 / 124.29 | 2 | 3 |
6 | 13 | 34.76 | 23 | 15.24 | 313 | 110 | 3.22 / 124.40 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.21 | 257 | 645 | 3.87 / 125.05 | 2 | 5 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 29 | 15.20 | 413 | 182 | 0.18 / 117.52 | 2 | 2 |
2 | 7 | 2005.72 | 30 | 14.92 | 2971 | 1330 | 1.51 / 118.84 | 2 | 6 |
3 | 13 | 1603.24 | 23 | 14.89 | 2451 | 839 | 2.35 / 119.68 | 2 | 4 |
4 | 13 | 873.56 | 23 | 15.03 | 1506 | 521 | 2.87 / 120.20 | 2 | 3 |
5 | 13 | 260.40 | 23 | 15.20 | 644 | 225 | 3.10 / 120.43 | 2 | 3 |
6 | 13 | 24.76 | 23 | 15.25 | 301 | 106 | 3.20 / 120.54 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.22 | 257 | 645 | 3.85 / 121.18 | 2 | 10 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 29 | 15.20 | 417 | 184 | 0.18 / 113.71 | 2 | 2 |
2 | 7 | 2005.92 | 30 | 14.92 | 2968 | 1328 | 1.51 / 115.04 | 2 | 2 |
3 | 13 | 1604.00 | 23 | 14.90 | 2459 | 843 | 2.35 / 115.89 | 2 | 3 |
4 | 13 | 880.32 | 23 | 15.03 | 1516 | 524 | 2.88 / 116.41 | 2 | 4 |
5 | 13 | 148.60 | 23 | 15.23 | 473 | 166 | 3.04 / 116.58 | 2 | 2 |
6 | 13 | 33.32 | 23 | 15.25 | 312 | 109 | 3.15 / 116.68 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.23 | 258 | 648 | 3.80 / 117.33 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 29 | 15.20 | 402 | 177 | 0.18 / 109.87 | 2 | 2 |
2 | 7 | 2005.20 | 30 | 14.92 | 2969 | 1329 | 1.51 / 111.20 | 2 | 2 |
3 | 13 | 1593.44 | 23 | 14.89 | 2436 | 834 | 2.34 / 112.04 | 2 | 3 |
4 | 13 | 865.28 | 23 | 15.03 | 1496 | 517 | 2.86 / 112.55 | 2 | 4 |
5 | 13 | 244.76 | 23 | 15.21 | 618 | 216 | 3.07 / 112.77 | 2 | 2 |
6 | 13 | 40.68 | 23 | 15.25 | 322 | 113 | 3.19 / 112.88 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.22 | 258 | 648 | 3.83 / 113.53 | 2 | 7 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 29 | 15.21 | 419 | 185 | 0.18 / 105.99 | 2 | 2 |
2 | 7 | 2005.08 | 30 | 14.94 | 2975 | 1333 | 1.52 / 107.32 | 2 | 3 |
3 | 13 | 1604.40 | 23 | 14.92 | 2459 | 844 | 2.36 / 108.17 | 2 | 3 |
4 | 13 | 984.72 | 23 | 15.01 | 1652 | 570 | 2.93 / 108.74 | 2 | 3 |
5 | 13 | 206.60 | 23 | 15.22 | 563 | 197 | 3.13 / 108.93 | 2 | 3 |
6 | 13 | 19.48 | 23 | 15.26 | 295 | 104 | 3.23 / 109.04 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.23 | 262 | 658 | 3.89 / 109.70 | 2 | 3 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.48 | 29 | 15.21 | 425 | 187 | 0.19 / 102.12 | 2 | 2 |
2 | 7 | 2011.68 | 31 | 14.93 | 2970 | 1375 | 1.56 / 103.49 | 2 | 2 |
3 | 13 | 1614.96 | 23 | 14.90 | 2474 | 848 | 2.41 / 104.34 | 2 | 3 |
4 | 13 | 889.24 | 23 | 15.04 | 1530 | 529 | 2.94 / 104.87 | 2 | 4 |
5 | 13 | 153.68 | 23 | 15.24 | 484 | 170 | 3.11 / 105.04 | 2 | 2 |
6 | 13 | 36.56 | 23 | 15.25 | 319 | 112 | 3.22 / 105.15 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.23 | 260 | 653 | 3.87 / 105.80 | 2 | 10 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 29 | 15.21 | 414 | 183 | 0.18 / 98.18 | 2 | 2 |
2 | 7 | 2006.40 | 30 | 14.93 | 2965 | 1328 | 1.51 / 99.51 | 2 | 2 |
3 | 13 | 1730.92 | 23 | 14.88 | 2619 | 896 | 2.41 / 100.41 | 2 | 2 |
4 | 13 | 971.84 | 23 | 15.02 | 1640 | 567 | 2.97 / 100.97 | 2 | 3 |
5 | 13 | 209.32 | 23 | 15.23 | 568 | 199 | 3.17 / 101.17 | 2 | 2 |
6 | 13 | 20.24 | 23 | 15.26 | 298 | 105 | 3.28 / 101.28 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.24 | 260 | 654 | 3.93 / 101.93 | 2 | 4 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 29 | 15.22 | 414 | 183 | 0.18 / 94.23 | 2 | 2 |
2 | 7 | 2007.84 | 30 | 14.95 | 2964 | 1329 | 1.51 / 95.56 | 2 | 4 |
3 | 13 | 1747.40 | 23 | 14.89 | 2642 | 905 | 2.42 / 96.47 | 2 | 3 |
4 | 13 | 970.72 | 23 | 15.02 | 1638 | 566 | 2.98 / 97.03 | 2 | 4 |
5 | 13 | 212.16 | 23 | 15.24 | 577 | 202 | 3.19 / 97.24 | 2 | 2 |
6 | 13 | 19.96 | 23 | 15.28 | 298 | 105 | 3.29 / 97.34 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.25 | 262 | 659 | 3.95 / 98.00 | 2 | 5 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 29 | 15.21 | 426 | 188 | 0.19 / 90.36 | 2 | 2 |
2 | 7 | 2004.56 | 30 | 14.96 | 2975 | 1335 | 1.52 / 91.69 | 2 | 5 |
3 | 13 | 1582.80 | 23 | 14.94 | 2435 | 837 | 2.36 / 92.53 | 2 | 3 |
4 | 13 | 979.60 | 23 | 15.04 | 1648 | 570 | 2.93 / 93.10 | 2 | 4 |
5 | 13 | 196.88 | 23 | 15.23 | 552 | 193 | 3.12 / 93.29 | 2 | 2 |
6 | 13 | 18.92 | 23 | 15.27 | 294 | 103 | 3.23 / 93.39 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.24 | 261 | 656 | 3.88 / 94.05 | 2 | 8 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 29 | 15.22 | 419 | 185 | 0.18 / 86.50 | 2 | 2 |
2 | 7 | 2006.40 | 30 | 14.96 | 2965 | 1331 | 1.52 / 87.83 | 2 | 3 |
3 | 13 | 1589.08 | 23 | 14.93 | 2451 | 842 | 2.36 / 88.67 | 2 | 3 |
4 | 13 | 867.32 | 23 | 15.05 | 1502 | 520 | 2.88 / 89.19 | 2 | 4 |
5 | 13 | 248.64 | 23 | 15.22 | 626 | 219 | 3.10 / 89.41 | 2 | 3 |
6 | 13 | 21.56 | 23 | 15.27 | 298 | 105 | 3.20 / 89.51 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.25 | 261 | 657 | 3.86 / 90.17 | 2 | 6 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 29 | 15.25 | 426 | 188 | 0.19 / 82.73 | 2 | 2 |
2 | 7 | 2003.44 | 30 | 14.95 | 2974 | 1334 | 1.52 / 84.06 | 2 | 3 |
3 | 13 | 1602.00 | 23 | 14.93 | 2462 | 845 | 2.37 / 84.91 | 2 | 3 |
4 | 13 | 873.76 | 23 | 15.06 | 1510 | 523 | 2.89 / 85.43 | 2 | 3 |
5 | 13 | 261.88 | 23 | 15.21 | 640 | 224 | 3.11 / 85.66 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.25 | 260 | 654 | 3.77 / 86.31 | 2 | 4 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.84 | 29 | 15.23 | 420 | 186 | 0.19 / 79.02 | 2 | 2 |
2 | 7 | 2001.80 | 30 | 14.96 | 2976 | 1336 | 1.52 / 80.36 | 2 | 3 |
3 | 13 | 1590.92 | 23 | 14.94 | 2449 | 842 | 2.36 / 81.20 | 2 | 3 |
4 | 13 | 869.88 | 23 | 15.06 | 1503 | 521 | 2.88 / 81.72 | 2 | 4 |
5 | 13 | 151.72 | 23 | 15.26 | 480 | 168 | 3.05 / 81.89 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.28 | 260 | 656 | 3.71 / 82.54 | 2 | 4 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 29 | 15.24 | 409 | 181 | 0.18 / 75.10 | 2 | 2 |
2 | 7 | 2010.04 | 30 | 14.96 | 2981 | 1338 | 1.52 / 76.44 | 2 | 2 |
3 | 13 | 1616.40 | 23 | 14.93 | 2473 | 849 | 2.37 / 77.29 | 2 | 4 |
4 | 13 | 1007.48 | 23 | 15.03 | 1686 | 583 | 2.95 / 77.87 | 2 | 5 |
5 | 13 | 226.60 | 23 | 15.26 | 589 | 207 | 3.16 / 78.08 | 2 | 2 |
6 | 13 | 17.20 | 23 | 15.30 | 287 | 101 | 3.26 / 78.18 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.27 | 260 | 655 | 3.91 / 78.83 | 2 | 6 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 29 | 15.23 | 425 | 188 | 0.19 / 71.18 | 2 | 2 |
2 | 7 | 2004.28 | 30 | 14.97 | 2972 | 1335 | 1.52 / 72.52 | 2 | 4 |
3 | 13 | 1735.04 | 23 | 14.92 | 2631 | 903 | 2.43 / 73.42 | 2 | 3 |
4 | 13 | 950.64 | 23 | 15.06 | 1611 | 558 | 2.98 / 73.98 | 2 | 4 |
5 | 13 | 188.84 | 23 | 15.26 | 534 | 187 | 3.17 / 74.17 | 2 | 2 |
6 | 13 | 18.44 | 23 | 15.30 | 288 | 101 | 3.27 / 74.27 | 2 | 3 |
7 | 8 | 0.24 | 165 | 15.27 | 259 | 653 | 3.92 / 74.92 | 2 | 7 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 29 | 15.24 | 429 | 190 | 0.19 / 67.32 | 2 | 2 |
2 | 7 | 2004.88 | 30 | 14.96 | 2969 | 1332 | 1.52 / 68.65 | 2 | 3 |
3 | 13 | 1581.84 | 23 | 14.94 | 2431 | 835 | 2.36 / 69.49 | 2 | 3 |
4 | 13 | 969.48 | 23 | 15.04 | 1633 | 565 | 2.92 / 70.05 | 2 | 4 |
5 | 13 | 188.92 | 23 | 15.27 | 538 | 189 | 3.11 / 70.24 | 2 | 2 |
6 | 13 | 17.20 | 23 | 15.28 | 288 | 101 | 3.21 / 70.34 | 2 | 2 |
7 | 8 | -0.12 | 165 | 15.27 | 259 | 653 | 3.87 / 71.00 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 29 | 15.25 | 400 | 177 | 0.18 / 63.45 | 2 | 2 |
2 | 7 | 2004.36 | 30 | 14.97 | 2969 | 1333 | 1.51 / 64.79 | 2 | 3 |
3 | 13 | 1587.92 | 23 | 14.96 | 2444 | 841 | 2.35 / 65.63 | 2 | 4 |
4 | 13 | 868.40 | 23 | 15.08 | 1504 | 522 | 2.87 / 66.15 | 2 | 4 |
5 | 13 | 255.44 | 23 | 15.24 | 634 | 222 | 3.10 / 66.37 | 2 | 2 |
6 | 13 | 16.40 | 23 | 15.30 | 288 | 101 | 3.20 / 66.47 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.27 | 261 | 658 | 3.85 / 67.13 | 2 | 9 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 29 | 15.24 | 403 | 178 | 0.18 / 59.68 | 2 | 2 |
2 | 7 | 2003.32 | 30 | 14.98 | 2980 | 1339 | 1.52 / 61.02 | 2 | 3 |
3 | 13 | 1597.60 | 23 | 14.96 | 2461 | 847 | 2.36 / 61.86 | 2 | 3 |
4 | 13 | 884.68 | 23 | 15.09 | 1524 | 529 | 2.89 / 62.39 | 2 | 4 |
5 | 13 | 265.00 | 23 | 15.24 | 647 | 227 | 3.12 / 62.62 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.29 | 261 | 658 | 3.78 / 63.28 | 2 | 6 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 29 | 15.25 | 429 | 190 | 0.19 / 55.93 | 2 | 2 |
2 | 7 | 2004.80 | 30 | 14.98 | 2973 | 1336 | 1.53 / 57.26 | 2 | 3 |
3 | 13 | 1485.72 | 23 | 14.98 | 2315 | 798 | 2.32 / 58.06 | 2 | 3 |
4 | 13 | 908.52 | 23 | 15.07 | 1555 | 539 | 2.86 / 58.60 | 2 | 4 |
5 | 13 | 280.44 | 23 | 15.24 | 670 | 235 | 3.10 / 58.84 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.28 | 263 | 663 | 3.76 / 59.50 | 2 | 4 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 29 | 15.25 | 404 | 179 | 0.18 / 52.14 | 2 | 2 |
2 | 7 | 2004.04 | 30 | 14.99 | 2986 | 1343 | 1.52 / 53.49 | 2 | 3 |
3 | 13 | 1588.92 | 23 | 14.96 | 2443 | 841 | 2.36 / 54.33 | 2 | 3 |
4 | 13 | 963.44 | 23 | 15.07 | 1632 | 566 | 2.93 / 54.89 | 2 | 5 |
5 | 13 | 190.88 | 23 | 15.28 | 541 | 190 | 3.12 / 55.08 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.30 | 260 | 656 | 3.77 / 55.74 | 2 | 3 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 29 | 15.26 | 423 | 187 | 0.19 / 48.38 | 2 | 2 |
2 | 7 | 2007.40 | 34 | 14.95 | 2980 | 1515 | 1.70 / 49.89 | 2 | 3 |
3 | 13 | 1442.64 | 19 | 15.00 | 2262 | 645 | 2.35 / 50.54 | 2 | 3 |
4 | 13 | 1002.20 | 19 | 15.06 | 1681 | 481 | 2.83 / 51.02 | 2 | 5 |
5 | 13 | 274.44 | 19 | 15.24 | 665 | 193 | 3.02 / 51.21 | 2 | 2 |
6 | 13 | 32.44 | 19 | 15.29 | 313 | 91 | 3.11 / 51.30 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.28 | 262 | 661 | 3.77 / 51.96 | 2 | 7 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 29 | 15.26 | 408 | 181 | 0.18 / 44.62 | 2 | 2 |
2 | 7 | 2003.04 | 34 | 14.96 | 2968 | 1510 | 1.69 / 46.13 | 2 | 2 |
3 | 13 | 1444.08 | 19 | 15.02 | 2262 | 646 | 2.34 / 46.77 | 2 | 3 |
4 | 13 | 996.52 | 19 | 15.07 | 1681 | 481 | 2.82 / 47.25 | 2 | 3 |
5 | 13 | 260.36 | 19 | 15.27 | 643 | 187 | 3.00 / 47.44 | 2 | 3 |
6 | 13 | 28.92 | 19 | 15.32 | 310 | 90 | 3.09 / 47.53 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.29 | 262 | 661 | 3.75 / 48.19 | 2 | 5 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 29 | 15.27 | 399 | 177 | 0.18 / 40.90 | 2 | 2 |
2 | 7 | 2004.80 | 34 | 14.95 | 2967 | 1508 | 1.68 / 42.41 | 2 | 4 |
3 | 13 | 1445.20 | 19 | 15.01 | 2264 | 646 | 2.33 / 43.06 | 2 | 3 |
4 | 13 | 867.92 | 19 | 15.11 | 1508 | 433 | 2.76 / 43.49 | 2 | 3 |
5 | 13 | 283.40 | 19 | 15.26 | 676 | 196 | 2.96 / 43.69 | 2 | 2 |
6 | 13 | 31.28 | 19 | 15.32 | 311 | 91 | 3.05 / 43.78 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.30 | 262 | 661 | 3.71 / 44.44 | 2 | 4 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 29 | 15.27 | 431 | 191 | 0.19 / 37.18 | 2 | 2 |
2 | 7 | 2003.36 | 34 | 14.96 | 2961 | 1506 | 1.70 / 38.69 | 2 | 3 |
3 | 13 | 1432.28 | 19 | 15.03 | 2247 | 642 | 2.34 / 39.33 | 2 | 3 |
4 | 13 | 984.24 | 19 | 15.07 | 1653 | 473 | 2.81 / 39.80 | 2 | 5 |
5 | 13 | 248.24 | 19 | 15.28 | 620 | 180 | 2.99 / 39.98 | 2 | 2 |
6 | 13 | 24.68 | 19 | 15.32 | 300 | 87 | 3.08 / 40.07 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.30 | 260 | 656 | 3.74 / 40.73 | 2 | 5 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.32 | 29 | 15.28 | 428 | 190 | 0.19 / 33.52 | 2 | 2 |
2 | 7 | 2003.60 | 34 | 14.96 | 2957 | 1504 | 1.69 / 35.02 | 2 | 4 |
3 | 13 | 1446.80 | 19 | 15.00 | 2260 | 644 | 2.34 / 35.66 | 2 | 3 |
4 | 13 | 997.80 | 19 | 15.07 | 1679 | 481 | 2.82 / 36.14 | 2 | 3 |
5 | 13 | 252.36 | 19 | 15.27 | 626 | 182 | 3.00 / 36.33 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.30 | 263 | 664 | 3.66 / 36.99 | 2 | 5 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 29 | 15.27 | 429 | 190 | 0.19 / 29.88 | 2 | 2 |
2 | 7 | 2005.84 | 34 | 14.95 | 2979 | 1514 | 1.70 / 31.40 | 2 | 2 |
3 | 13 | 1421.68 | 19 | 15.02 | 2227 | 636 | 2.34 / 32.03 | 2 | 3 |
4 | 13 | 865.60 | 19 | 15.11 | 1498 | 430 | 2.77 / 32.46 | 2 | 5 |
5 | 13 | 280.96 | 19 | 15.26 | 672 | 195 | 2.96 / 32.66 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.30 | 265 | 669 | 3.63 / 33.33 | 2 | 3 |
Average= | 3.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 29 | 15.28 | 421 | 187 | 0.19 / 26.26 | 2 | 2 |
2 | 7 | 2004.56 | 35 | 14.96 | 2973 | 1557 | 1.74 / 27.81 | 2 | 3 |
3 | 13 | 1447.68 | 18 | 15.01 | 2263 | 611 | 2.35 / 28.42 | 2 | 3 |
4 | 13 | 883.16 | 18 | 15.11 | 1526 | 415 | 2.77 / 28.84 | 2 | 4 |
5 | 13 | 299.20 | 18 | 15.26 | 701 | 193 | 2.96 / 29.03 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.31 | 262 | 662 | 3.62 / 29.69 | 2 | 5 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 29 | 15.29 | 413 | 183 | 0.18 / 22.58 | 2 | 2 |
2 | 7 | 2008.84 | 36 | 14.96 | 2970 | 1600 | 1.78 / 24.18 | 2 | 3 |
3 | 13 | 1442.00 | 18 | 15.03 | 2254 | 610 | 2.39 / 24.79 | 2 | 6 |
4 | 13 | 877.32 | 18 | 15.13 | 1519 | 414 | 2.81 / 25.21 | 2 | 4 |
5 | 13 | 295.76 | 18 | 15.28 | 697 | 192 | 3.00 / 25.40 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.31 | 265 | 669 | 3.67 / 26.07 | 2 | 2 |
Average= | 3.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 28 | 15.29 | 424 | 182 | 0.18 / 18.86 | 2 | 2 |
2 | 3 | 1030.36 | 1 | 15.31 | 1771 | 27 | 0.21 / 18.89 | 2 | 2 |
3 | 7 | 2003.72 | 38 | 14.94 | 2963 | 1682 | 1.89 / 20.57 | 2 | 3 |
4 | 13 | 1392.68 | 18 | 15.04 | 2200 | 596 | 2.49 / 21.17 | 2 | 3 |
5 | 13 | 818.00 | 18 | 15.15 | 1440 | 393 | 2.88 / 21.56 | 2 | 3 |
6 | 13 | 232.48 | 18 | 15.30 | 607 | 167 | 3.05 / 21.73 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.32 | 266 | 672 | 3.72 / 22.40 | 2 | 3 |
Average= | 3.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 29 | 15.29 | 474 | 210 | 0.21 / 15.18 | 2 | 2 |
2 | 3 | 949.80 | -1 | 15.58 | 0 | 0 | 0.00 / 15.18 | 2 | 2 |
3 | 7 | 2003.00 | 38 | 14.96 | 2962 | 1684 | 1.89 / 16.86 | 2 | 4 |
4 | 13 | 1398.16 | 18 | 15.05 | 2198 | 595 | 2.49 / 17.46 | 2 | 3 |
5 | 13 | 807.52 | 18 | 15.17 | 1421 | 388 | 2.88 / 17.85 | 2 | 4 |
6 | 13 | 218.60 | 18 | 15.30 | 584 | 161 | 3.04 / 18.01 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.33 | 267 | 675 | 3.71 / 18.68 | 2 | 5 |
Average= | 3.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 27 | 15.30 | 416 | 172 | 0.17 / 11.88 | 2 | 2 |
2 | 7 | 1512.08 | 38 | 15.11 | 2332 | 1339 | 1.51 / 13.21 | 2 | 3 |
3 | 13 | 1129.48 | 18 | 15.14 | 1846 | 503 | 2.01 / 13.72 | 2 | 3 |
4 | 13 | 695.24 | 18 | 15.20 | 1275 | 349 | 2.36 / 14.07 | 2 | 4 |
5 | 13 | 117.20 | 18 | 15.35 | 447 | 124 | 2.49 / 14.19 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.33 | 308 | 779 | 3.27 / 14.97 | 2 | 6 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 27 | 15.31 | 420 | 174 | 0.17 / 8.30 | 2 | 2 |
2 | 7 | 1524.72 | 74 | 15.01 | 2341 | 2600 | 2.77 / 10.90 | 2 | 3 |
3 | 13 | 152.00 | 18 | 15.34 | 484 | 134 | 2.91 / 11.04 | 2 | 2 |
4 | 8 | 0.16 | 165 | 15.34 | 263 | 666 | 3.57 / 11.70 | 2 | 3 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 32 | 15.29 | 475 | 232 | 0.23 / 4.78 | 2 | 2 |
2 | 3 | 828.72 | -3 | 15.59 | 0 | 0 | 0.00 / 4.78 | 2 | 2 |
3 | 3 | 957.56 | -1 | 15.61 | 0 | 0 | 0.00 / 4.78 | 2 | 2 |
4 | 7 | 1505.92 | 74 | 15.01 | 2306 | 2561 | 2.79 / 7.34 | 2 | 4 |
5 | 13 | 137.28 | 18 | 15.34 | 458 | 126 | 2.92 / 7.47 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.34 | 261 | 661 | 3.58 / 8.13 | 2 | 4 |
Average= | 2.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 27 | 15.44 | 443 | 185 | 0.18 / 1.89 | 2 | 3 |
2 | 7 | 999.04 | 74 | 15.15 | 1685 | 1889 | 2.07 / 3.78 | 2 | 4 |
3 | 8 | 0.00 | 165 | 15.34 | 306 | 775 | 2.85 / 4.55 | 2 | 7 |
Average= | 2.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 126.36 | 26 | 15.58 | 417 | 169 | 0.17 / 0.17 | 2 | 3 |
2 | 7 | 140.24 | 75 | 15.55 | 446 | 520 | 0.69 / 0.69 | 2 | 2 |
3 | 8 | 0.24 | 240 | 15.51 | 272 | 1012 | 1.70 / 1.70 | 2 | 3 |
Average= | 1.70 (KJ/cycle) |