SIO Argo Site:
Pump Diagnostics Page   



Serial= 8902 WMO= 5906400

Return

←PreviousNext→

Cycle 154 GMT 2/12/2024 7: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 32 14.97 394 189 0.19 / 610.10 3 3
2 12 1308.56 3 15.15 2075 94 0.28 / 610.20 2 3
3 7 2003.64 30 14.86 2811 1253 1.54 / 611.45 2 5
4 13 1610.20 31 14.81 2338 1073 2.61 / 612.53 2 7
5 13 791.80 31 14.89 1319 609 3.22 / 613.13 2 4
6 13 119.84 31 15.01 426 198 3.42 / 613.33 2 3
7 8 0.12 165 15.01 252 624 4.04 / 613.96 3 9
Average= 3.96
(KJ/cycle)

Cycle 153 GMT 22/11/2024 12:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 32 14.96 388 186 0.19 / 606.16 3 3
2 12 1300.92 3 15.17 2051 93 0.28 / 606.26 2 4
3 7 2004.76 30 14.87 2815 1256 1.53 / 607.51 2 5
4 13 1603.40 31 14.82 2330 1070 2.61 / 608.58 2 7
5 13 682.44 31 14.90 1170 540 3.15 / 609.12 2 4
6 13 96.32 31 15.02 390 182 3.33 / 609.30 2 2
7 8 0.00 165 15.00 247 611 3.94 / 609.92 2 8
Average= 3.96
(KJ/cycle)

Cycle 152 GMT 12/11/2024 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 14.98 390 187 0.19 / 602.06 3 3
2 12 1306.04 3 15.16 2093 95 0.28 / 602.16 2 3
3 7 2008.92 30 14.86 2824 1259 1.54 / 603.41 2 3
4 13 1740.68 31 14.78 2493 1142 2.68 / 604.56 2 3
5 13 768.76 31 14.91 1288 595 3.28 / 605.15 2 5
6 13 109.44 31 15.02 417 194 3.47 / 605.35 2 3
7 8 0.08 165 15.00 255 631 4.10 / 605.98 2 9
Average= 3.96
(KJ/cycle)

Cycle 151 GMT 2/11/2024 21:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 32 14.96 392 188 0.19 / 597.97 3 3
2 12 1309.48 3 15.18 2079 95 0.28 / 598.07 2 3
3 7 2007.64 31 14.87 2814 1297 1.58 / 599.36 2 4
4 13 1606.92 31 14.81 2331 1070 2.65 / 600.43 2 7
5 13 804.96 31 14.87 1329 613 3.26 / 601.05 2 5
6 13 123.40 31 15.01 433 201 3.46 / 601.25 2 3
7 8 0.08 165 15.00 253 626 4.09 / 601.87 2 6
Average= 3.96
(KJ/cycle)

Cycle 150 GMT 24/10/2024 2:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 32 14.97 387 185 0.19 / 594.01 3 3
2 12 1295.88 3 15.18 2069 94 0.28 / 594.11 2 4
3 7 2003.56 30 14.87 2805 1251 1.53 / 595.36 2 4
4 13 1604.12 31 14.80 2333 1070 2.60 / 596.43 2 3
5 13 678.76 31 14.92 1173 543 3.14 / 596.97 2 5
6 13 95.56 31 15.03 398 185 3.33 / 597.16 2 3
7 8 0.00 165 15.00 253 626 3.96 / 597.78 2 8
Average= 3.96
(KJ/cycle)

Cycle 149 GMT 14/10/2024 7:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 32 14.94 399 191 0.19 / 590.02 3 3
2 12 1303.64 3 15.20 2053 94 0.28 / 590.11 2 4
3 7 2002.32 30 14.88 2813 1256 1.54 / 591.37 2 6
4 13 1730.52 31 14.80 2479 1137 2.68 / 592.50 2 4
5 13 641.40 31 14.95 1125 521 3.20 / 593.02 2 5
6 13 86.84 31 15.05 384 179 3.38 / 593.20 2 3
7 8 0.08 165 15.02 252 625 4.00 / 593.83 2 8
Average= 3.96
(KJ/cycle)

Cycle 148 GMT 4/10/2024 12:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 32 14.98 388 186 0.19 / 585.87 3 3
2 12 1306.00 3 15.17 2053 93 0.28 / 585.96 2 3
3 7 2005.92 31 14.87 2814 1297 1.58 / 587.26 2 4
4 13 1736.56 31 14.79 2493 1143 2.72 / 588.40 2 3
5 13 769.64 31 14.90 1286 594 3.31 / 589.00 2 3
6 13 121.76 31 15.02 431 201 3.51 / 589.20 2 3
7 8 -0.04 165 14.99 254 628 4.14 / 589.82 2 4
Average= 3.96
(KJ/cycle)

Cycle 147 GMT 24/ 9/2024 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 32 14.99 392 188 0.19 / 581.88 3 3
2 12 1292.56 3 15.17 2059 94 0.28 / 581.97 2 3
3 7 2002.08 30 14.87 2809 1253 1.53 / 583.23 2 3
4 13 1725.88 31 14.79 2478 1136 2.67 / 584.36 2 6
5 13 641.56 31 14.93 1120 518 3.19 / 584.88 2 4
6 13 87.24 31 15.03 383 178 3.37 / 585.06 2 3
7 8 0.20 165 15.01 251 622 3.99 / 585.68 3 14
Average= 3.96
(KJ/cycle)

Cycle 146 GMT 14/ 9/2024 22:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 32 14.97 385 184 0.18 / 577.92 3 3
2 12 1302.08 3 15.16 2089 95 0.28 / 578.01 2 4
3 7 2004.20 30 14.88 2819 1258 1.54 / 579.27 2 3
4 13 1604.08 31 14.82 2327 1069 2.61 / 580.34 2 4
5 13 678.12 31 14.94 1168 541 3.15 / 580.88 2 5
6 13 88.40 31 15.03 388 181 3.33 / 581.06 2 4
7 8 -0.08 165 15.00 255 631 3.96 / 581.69 3 7
Average= 3.96
(KJ/cycle)

Cycle 145 GMT 5/ 9/2024 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 32 14.96 390 187 0.19 / 573.85 3 3
2 12 1312.24 3 15.17 2065 94 0.28 / 573.94 2 3
3 7 2006.16 31 14.85 2811 1294 1.57 / 575.24 2 3
4 13 1607.52 31 14.80 2337 1072 2.65 / 576.31 2 4
5 13 816.88 31 14.89 1349 623 3.27 / 576.93 2 4
6 13 79.00 31 15.04 373 174 3.44 / 577.10 2 4
7 8 0.16 165 15.01 254 629 4.07 / 577.73 2 3
Average= 3.96
(KJ/cycle)

Cycle 144 GMT 26/ 8/2024 8:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 32 14.98 395 189 0.19 / 569.90 3 3
2 12 1307.24 3 15.19 2060 94 0.28 / 570.00 2 5
3 7 2003.04 30 14.88 2818 1258 1.54 / 571.25 2 5
4 13 1599.80 31 14.82 2331 1071 2.61 / 572.32 2 5
5 13 667.08 31 14.93 1153 534 3.15 / 572.86 2 5
6 13 86.28 31 15.03 383 178 3.32 / 573.04 2 4
7 8 0.12 165 15.00 252 624 3.95 / 573.66 3 5
Average= 3.96
(KJ/cycle)

Cycle 143 GMT 16/ 8/2024 13:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 32 14.96 393 188 0.19 / 565.80 3 3
2 12 1315.92 3 15.17 2093 95 0.28 / 565.89 2 3
3 7 2002.88 30 14.87 2811 1254 1.54 / 567.14 2 6
4 13 1744.76 31 14.79 2499 1146 2.68 / 568.29 2 5
5 13 773.04 31 14.91 1292 597 3.28 / 568.89 2 3
6 13 118.88 31 15.03 427 199 3.48 / 569.09 2 4
7 8 -0.04 165 15.00 253 626 4.11 / 569.71 2 3
Average= 3.96
(KJ/cycle)

Cycle 142 GMT 6/ 8/2024 18:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 32 14.97 394 189 0.19 / 561.76 3 3
2 12 1310.36 3 15.18 2089 95 0.28 / 561.86 2 3
3 7 2003.28 30 14.87 2806 1252 1.54 / 563.11 2 4
4 13 1608.80 31 14.80 2326 1067 2.60 / 564.18 2 10
5 13 791.32 31 14.90 1310 605 3.21 / 564.78 2 4
6 13 128.04 31 15.02 437 203 3.41 / 564.99 2 5
7 8 -0.04 165 15.01 251 622 4.03 / 565.61 2 3
Average= 3.96
(KJ/cycle)

Cycle 141 GMT 27/ 7/2024 23:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 32 14.96 398 191 0.19 / 557.83 3 3
2 12 1301.48 3 15.19 2073 94 0.28 / 557.92 2 3
3 7 2007.64 30 14.87 2827 1261 1.55 / 559.18 2 4
4 13 1595.12 31 14.82 2316 1064 2.61 / 560.24 2 5
5 13 658.40 31 14.92 1141 528 3.14 / 560.77 2 4
6 13 93.40 31 15.03 387 180 3.32 / 560.95 2 4
7 8 0.04 165 15.01 251 622 3.94 / 561.57 2 9
Average= 3.95
(KJ/cycle)

Cycle 140 GMT 18/ 7/2024 4:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 32 14.97 399 191 0.19 / 553.77 3 3
2 12 1312.36 3 15.16 2075 94 0.29 / 553.87 2 3
3 7 2003.56 30 14.87 2820 1258 1.54 / 555.12 2 3
4 13 1598.36 31 14.82 2323 1067 2.61 / 556.19 2 4
5 13 802.44 31 14.90 1327 613 3.22 / 556.80 2 4
6 13 125.68 31 15.02 438 204 3.43 / 557.01 2 4
7 8 0.00 165 14.99 253 626 4.05 / 557.63 2 8
Average= 3.95
(KJ/cycle)

Cycle 139 GMT 8/ 7/2024 9:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 32 14.97 396 190 0.19 / 549.72 3 3
2 12 1287.84 3 15.18 2046 93 0.28 / 549.82 2 3
3 7 2004.92 30 14.87 2815 1256 1.54 / 551.07 2 5
4 13 1596.00 31 14.81 2315 1063 2.60 / 552.14 2 3
5 13 801.20 31 14.90 1324 612 3.21 / 552.75 2 4
6 13 122.36 31 15.04 433 202 3.41 / 552.95 2 5
7 8 0.08 165 15.00 255 631 4.05 / 553.58 3 11
Average= 3.95
(KJ/cycle)

Cycle 138 GMT 28/ 6/2024 14:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 32 14.98 392 188 0.19 / 545.77 3 3
2 12 1293.84 3 15.19 2057 94 0.28 / 545.86 2 5
3 7 2002.44 30 14.88 2812 1255 1.54 / 547.12 2 3
4 13 1606.12 31 14.81 2328 1069 2.61 / 548.18 2 7
5 13 691.32 31 14.92 1187 549 3.15 / 548.73 2 4
6 13 98.04 31 15.03 398 185 3.34 / 548.92 2 3
7 8 0.00 165 15.01 249 617 3.96 / 549.54 3 13
Average= 3.95
(KJ/cycle)

Cycle 137 GMT 18/ 6/2024 19:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 32 14.98 398 191 0.19 / 541.67 3 3
2 12 1299.00 3 15.19 2045 93 0.28 / 541.76 2 3
3 7 2004.00 30 14.88 2818 1258 1.54 / 543.02 2 4
4 13 1733.08 31 14.80 2480 1138 2.68 / 544.16 2 4
5 13 767.28 31 14.91 1281 592 3.27 / 544.75 2 4
6 13 121.16 31 15.04 429 200 3.47 / 544.95 2 3
7 8 0.04 165 15.01 254 629 4.10 / 545.58 2 6
Average= 3.95
(KJ/cycle)

Cycle 136 GMT 9/ 6/2024 0:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 32 14.99 391 188 0.19 / 537.63 3 3
2 12 1313.48 3 15.20 2076 95 0.28 / 537.72 2 3
3 7 2004.52 30 14.90 2815 1258 1.54 / 538.98 2 4
4 13 1597.80 31 14.83 2315 1064 2.60 / 540.04 2 4
5 13 791.84 31 14.91 1314 607 3.21 / 540.65 2 5
6 13 121.12 31 15.03 427 199 3.41 / 540.85 2 3
7 8 -0.08 165 15.02 253 627 4.04 / 541.48 2 5
Average= 3.95
(KJ/cycle)

Cycle 135 GMT 30/ 5/2024 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 32 14.98 399 191 0.19 / 533.56 3 4
2 12 1306.04 3 15.18 2073 94 0.29 / 533.65 2 3
3 7 2003.32 30 14.89 2817 1258 1.54 / 534.91 2 3
4 13 1596.52 31 14.83 2324 1068 2.61 / 535.98 2 6
5 13 678.92 31 14.93 1165 539 3.15 / 536.52 2 5
6 13 101.52 31 15.04 402 187 3.34 / 536.71 3 8
7 8 0.08 165 15.01 250 619 3.96 / 537.33 2 3
8 14 0.08 30 14.99 249 112 4.07 / 537.44 3 14
Average= 3.95
(KJ/cycle)

Cycle 134 GMT 20/ 5/2024 10:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 32 14.99 395 189 0.19 / 529.51 3 3
2 12 1297.72 3 15.18 2069 94 0.28 / 529.61 2 4
3 7 2002.64 30 14.87 2809 1253 1.54 / 530.86 2 4
4 13 1593.64 31 14.83 2319 1066 2.60 / 531.92 2 4
5 13 796.44 31 14.90 1318 609 3.21 / 532.53 2 6
6 13 124.60 31 15.04 436 203 3.41 / 532.74 2 3
7 8 0.04 165 15.02 255 632 4.05 / 533.37 2 5
Average= 3.95
(KJ/cycle)

Cycle 133 GMT 10/ 5/2024 15:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 32 14.98 398 191 0.19 / 525.52 3 3
2 12 1315.20 3 15.19 2078 95 0.29 / 525.62 2 3
3 7 2008.36 30 14.88 2822 1260 1.55 / 526.88 2 5
4 13 1608.60 31 14.83 2342 1077 2.62 / 527.96 2 5
5 13 689.40 31 14.93 1188 550 3.17 / 528.51 2 5
6 13 103.44 31 15.05 407 190 3.36 / 528.70 2 3
7 8 -0.04 165 15.02 253 627 3.99 / 529.32 2 5
Average= 3.95
(KJ/cycle)

Cycle 132 GMT 30/ 4/2024 20:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 32 14.98 395 189 0.19 / 521.47 3 3
2 12 1321.32 3 15.15 2077 94 0.28 / 521.57 2 3
3 7 2006.64 30 14.87 2817 1257 1.54 / 522.82 2 4
4 13 1612.04 31 14.82 2338 1074 2.61 / 523.90 2 4
5 13 790.36 31 14.91 1310 605 3.22 / 524.50 2 4
6 13 117.56 31 15.03 428 199 3.42 / 524.70 2 3
7 8 0.16 165 15.01 255 632 4.05 / 525.33 2 5
Average= 3.95
(KJ/cycle)

Cycle 131 GMT 21/ 4/2024 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 14.98 393 188 0.19 / 517.47 3 3
2 12 1302.08 3 15.19 2089 95 0.28 / 517.56 2 4
3 7 2008.32 31 14.89 2818 1301 1.58 / 518.86 2 4
4 13 1604.04 31 14.83 2335 1073 2.66 / 519.94 2 6
5 13 671.48 31 14.95 1158 537 3.19 / 520.47 2 7
6 13 90.68 31 15.05 390 182 3.38 / 520.65 2 3
7 8 0.00 165 15.03 253 627 4.00 / 521.28 3 3
Average= 3.95
(KJ/cycle)

Cycle 130 GMT 11/ 4/2024 6: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 32 14.99 396 190 0.19 / 513.40 3 3
2 12 1317.48 3 15.19 2073 94 0.28 / 513.49 2 5
3 7 2006.48 30 14.88 2820 1259 1.54 / 514.75 2 5
4 13 1595.92 31 14.83 2315 1064 2.61 / 515.82 2 5
5 13 664.76 31 14.95 1155 535 3.14 / 516.35 2 4
6 13 92.28 31 15.05 393 183 3.33 / 516.54 2 3
7 8 0.04 165 15.03 254 630 3.96 / 517.17 3 5
8 14 0.04 30 15.00 251 113 4.07 / 517.28 3 11
Average= 3.95
(KJ/cycle)

Cycle 129 GMT 1/ 4/2024 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 32 14.99 395 189 0.19 / 509.41 3 3
2 12 1298.76 3 15.20 2071 94 0.28 / 509.51 2 3
3 7 2006.08 30 14.89 2825 1262 1.55 / 510.77 2 6
4 13 1615.08 31 14.83 2344 1078 2.62 / 511.85 2 7
5 13 687.16 31 14.95 1180 547 3.17 / 512.39 2 3
6 13 93.00 31 15.06 396 185 3.36 / 512.58 2 3
7 8 0.00 165 15.03 255 632 3.99 / 513.21 2 6
Average= 3.95
(KJ/cycle)

Cycle 128 GMT 22/ 3/2024 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 32 15.00 397 191 0.19 / 505.30 3 3
2 12 1308.04 3 15.19 2073 94 0.29 / 505.40 2 4
3 7 2007.24 30 14.89 2818 1259 1.54 / 506.65 2 4
4 13 1733.20 31 14.81 2487 1142 2.69 / 507.80 2 8
5 13 777.28 31 14.91 1292 597 3.28 / 508.39 2 7
6 13 105.88 31 15.03 416 194 3.48 / 508.59 2 3
7 8 -0.08 165 15.02 256 634 4.11 / 509.22 2 3
Average= 3.95
(KJ/cycle)

Cycle 127 GMT 12/ 3/2024 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 32 14.99 390 187 0.19 / 501.35 3 3
2 12 1301.36 3 15.20 2050 93 0.28 / 501.45 2 4
3 7 2002.20 30 14.89 2811 1256 1.54 / 502.70 2 5
4 13 1590.88 31 14.83 2313 1063 2.60 / 503.76 2 6
5 13 673.84 31 14.94 1157 536 3.14 / 504.30 2 4
6 13 89.76 31 15.05 387 181 3.32 / 504.48 2 3
7 8 0.08 165 15.03 254 630 3.95 / 505.11 2 7
Average= 3.95
(KJ/cycle)

Cycle 126 GMT 3/ 3/2024 1:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 32 14.98 403 193 0.19 / 497.37 3 3
2 12 1309.04 3 15.19 2072 94 0.29 / 497.46 2 4
3 7 2002.04 30 14.89 2805 1253 1.54 / 498.72 2 3
4 13 1720.24 31 14.81 2467 1133 2.67 / 499.85 2 3
5 13 634.64 31 14.97 1105 513 3.19 / 500.36 2 4
6 13 91.40 31 15.06 387 181 3.37 / 500.54 2 4
7 8 -0.16 165 15.03 251 622 3.99 / 501.16 3 11
Average= 3.95
(KJ/cycle)

Cycle 125 GMT 22/ 2/2024 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 32 15.00 400 192 0.19 / 493.27 3 3
2 12 1323.20 3 15.19 2102 96 0.29 / 493.36 2 3
3 7 2003.04 30 14.89 2804 1253 1.54 / 494.62 2 3
4 13 1736.92 31 14.80 2485 1140 2.68 / 495.76 2 8
5 13 760.20 31 14.93 1271 588 3.27 / 496.35 2 4
6 13 123.56 31 15.05 434 202 3.47 / 496.55 2 3
7 8 0.04 165 15.03 253 627 4.10 / 497.18 3 4
Average= 3.95
(KJ/cycle)

Cycle 124 GMT 12/ 2/2024 11:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 32 15.00 400 192 0.19 / 489.16 3 3
2 12 1307.28 3 15.20 2077 95 0.29 / 489.25 2 3
3 7 2002.60 30 14.90 2820 1261 1.55 / 490.52 2 3
4 13 1732.48 31 14.81 2480 1139 2.69 / 491.65 2 9
5 13 755.44 31 14.94 1270 588 3.27 / 492.24 2 4
6 13 118.80 31 15.04 430 200 3.47 / 492.44 2 3
7 8 0.12 165 15.02 256 634 4.11 / 493.08 2 5
Average= 3.94
(KJ/cycle)

Cycle 123 GMT 2/ 2/2024 16:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 32 14.99 393 189 0.19 / 485.07 3 3
2 12 1319.08 3 15.18 2077 95 0.28 / 485.16 2 3
3 7 2002.16 30 14.88 2818 1258 1.54 / 486.42 2 4
4 13 1727.96 31 14.81 2473 1135 2.68 / 487.55 2 7
5 13 757.20 31 14.94 1270 588 3.26 / 488.14 2 3
6 13 114.76 31 15.05 422 197 3.46 / 488.34 2 4
7 8 0.08 165 15.02 254 629 4.09 / 488.97 2 8
Average= 3.94
(KJ/cycle)

Cycle 122 GMT 23/ 1/2024 21:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 32 14.98 402 193 0.19 / 481.04 3 3
2 12 1314.52 3 15.19 2066 94 0.29 / 481.14 2 3
3 7 2005.08 31 14.91 2820 1303 1.59 / 482.44 2 3
4 13 1606.40 31 14.84 2332 1073 2.66 / 483.51 2 7
5 13 679.08 31 14.95 1170 542 3.21 / 484.06 2 3
6 13 95.60 31 15.04 398 186 3.39 / 484.24 2 3
7 8 0.04 165 15.04 256 635 4.03 / 484.88 3 5
Average= 3.94
(KJ/cycle)

Cycle 121 GMT 14/ 1/2024 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 32 15.00 398 191 0.19 / 476.98 3 3
2 12 1305.12 3 15.20 2095 96 0.29 / 477.07 2 5
3 7 2004.68 30 14.89 2817 1258 1.54 / 478.33 2 3
4 13 1592.20 31 14.83 2317 1065 2.61 / 479.40 2 4
5 13 806.80 31 14.91 1333 616 3.23 / 480.01 2 4
6 13 123.32 31 15.05 435 203 3.43 / 480.22 2 3
7 8 -0.12 165 15.02 256 634 4.06 / 480.85 3 4
Average= 3.94
(KJ/cycle)

Cycle 120 GMT 4/ 1/2024 7:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 32 15.00 395 190 0.19 / 472.89 3 3
2 12 1317.84 3 15.19 2079 95 0.28 / 472.98 2 4
3 7 2003.28 30 14.89 2819 1259 1.54 / 474.24 2 5
4 13 1607.04 31 14.84 2343 1078 2.62 / 475.32 2 4
5 13 682.04 31 14.95 1171 543 3.16 / 475.86 2 3
6 13 96.48 31 15.05 400 187 3.35 / 476.05 2 4
7 8 0.24 165 15.02 253 627 3.98 / 476.67 3 6
8 14 0.24 30 15.00 253 114 4.09 / 476.79 3 5
Average= 3.94
(KJ/cycle)

Cycle 119 GMT 25/12/2023 12:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 32 15.01 397 191 0.19 / 468.90 3 3
2 12 1308.76 3 15.19 2070 94 0.29 / 469.00 2 4
3 7 2007.00 30 14.90 2828 1264 1.55 / 470.26 2 5
4 13 1596.44 31 14.84 2324 1069 2.62 / 471.33 2 5
5 13 684.32 31 14.94 1178 546 3.16 / 471.88 2 3
6 13 94.88 31 15.05 397 185 3.35 / 472.06 2 3
7 8 0.24 165 15.04 255 633 3.98 / 472.70 2 6
Average= 3.94
(KJ/cycle)

Cycle 118 GMT 15/12/2023 17:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 32 14.99 388 186 0.19 / 464.93 3 3
2 12 1308.32 3 15.19 2088 95 0.28 / 465.03 2 3
3 7 2003.00 30 14.89 2819 1259 1.54 / 466.29 2 4
4 13 1591.44 31 14.86 2317 1067 2.61 / 467.36 2 4
5 13 677.08 31 14.95 1169 542 3.15 / 467.90 2 4
6 13 97.04 31 15.06 405 189 3.34 / 468.09 2 3
7 8 0.04 165 15.04 253 628 3.97 / 468.71 2 7
Average= 3.94
(KJ/cycle)

Cycle 117 GMT 5/12/2023 22: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 32 15.01 390 187 0.19 / 460.72 3 3
2 12 1317.28 3 15.19 2076 95 0.28 / 460.81 2 6
3 7 2004.72 30 14.88 2820 1259 1.54 / 462.07 2 4
4 13 1731.40 31 14.80 2485 1140 2.68 / 463.21 2 5
5 13 760.64 31 14.92 1274 589 3.27 / 463.80 2 4
6 13 109.76 31 15.05 418 195 3.47 / 464.00 2 3
7 8 0.00 165 15.03 257 637 4.10 / 464.63 2 6
8 14 0.00 30 15.01 255 115 4.22 / 464.75 3 13
Average= 3.94
(KJ/cycle)

Cycle 116 GMT 26/11/2023 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 32 15.01 408 196 0.20 / 456.67 3 3
2 12 1317.52 3 15.18 2090 95 0.29 / 456.76 2 3
3 7 2003.76 30 14.88 2810 1254 1.55 / 458.02 2 3
4 13 1598.76 31 14.83 2324 1068 2.61 / 459.09 2 5
5 13 788.88 31 14.92 1315 608 3.22 / 459.69 2 5
6 13 116.20 31 15.06 429 200 3.42 / 459.90 2 3
7 8 0.00 165 15.03 256 635 4.06 / 460.53 2 8
Average= 3.94
(KJ/cycle)

Cycle 115 GMT 16/11/2023 7:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 32 14.99 397 190 0.19 / 452.69 3 3
2 12 1313.04 3 15.20 2084 95 0.29 / 452.78 2 4
3 7 2008.52 30 14.88 2825 1261 1.55 / 454.04 2 4
4 13 1609.08 31 14.83 2333 1073 2.62 / 455.11 2 6
5 13 678.60 31 14.96 1170 543 3.16 / 455.66 2 6
6 13 94.68 31 15.06 397 185 3.35 / 455.84 2 4
7 8 0.04 165 15.03 254 630 3.98 / 456.47 3 3
Average= 3.94
(KJ/cycle)

Cycle 114 GMT 6/11/2023 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 32 15.01 391 188 0.19 / 448.78 3 3
2 12 1296.72 3 15.20 2060 94 0.28 / 448.87 2 3
3 7 2002.32 30 14.89 2809 1255 1.54 / 450.12 2 3
4 13 1474.72 31 14.86 2170 1000 2.54 / 451.12 2 4
5 13 708.52 31 14.94 1208 559 3.10 / 451.68 2 3
6 13 94.88 31 15.05 397 185 3.28 / 451.87 2 3
7 8 -0.12 165 15.03 253 627 3.91 / 452.50 2 8
Average= 3.93
(KJ/cycle)

Cycle 113 GMT 27/10/2023 17:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 32 14.99 393 189 0.19 / 444.82 3 3
2 12 1293.48 3 15.21 2053 94 0.28 / 444.91 2 3
3 7 2002.56 30 14.90 2819 1260 1.54 / 446.17 2 3
4 13 1595.28 31 14.83 2318 1066 2.61 / 447.24 2 4
5 13 673.20 31 14.95 1157 536 3.14 / 447.77 2 5
6 13 92.56 31 15.07 393 184 3.33 / 447.96 2 4
7 8 -0.04 165 15.04 254 630 3.96 / 448.59 3 5
Average= 3.93
(KJ/cycle)

Cycle 112 GMT 17/10/2023 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 32 14.98 399 191 0.19 / 440.75 3 3
2 12 1288.68 3 15.18 2051 93 0.28 / 440.85 2 4
3 7 2006.48 30 14.89 2820 1260 1.54 / 442.11 2 3
4 13 1599.84 31 14.84 2336 1075 2.62 / 443.18 2 5
5 13 799.16 31 14.92 1326 613 3.23 / 443.79 2 4
6 13 122.92 31 15.05 434 202 3.43 / 444.00 2 3
7 8 -0.04 165 15.02 255 632 4.07 / 444.63 2 6
Average= 3.93
(KJ/cycle)

Cycle 111 GMT 8/10/2023 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 32 14.99 392 188 0.19 / 436.70 3 3
2 12 1306.16 3 15.20 2051 94 0.28 / 436.79 2 4
3 7 2009.40 30 14.88 2821 1259 1.54 / 438.05 2 6
4 13 1608.52 31 14.84 2344 1078 2.62 / 439.13 2 6
5 13 785.64 31 14.93 1309 606 3.23 / 439.74 2 6
6 13 112.92 31 15.06 423 197 3.42 / 439.93 2 5
7 8 -0.08 165 15.03 254 630 4.05 / 440.56 2 4
Average= 3.93
(KJ/cycle)

Cycle 110 GMT 28/ 9/2023 8:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 32 15.00 394 189 0.19 / 432.72 3 3
2 12 1303.68 3 15.21 2062 94 0.28 / 432.82 2 5
3 7 2007.96 31 14.90 2818 1302 1.58 / 434.12 2 5
4 13 1488.08 31 14.85 2196 1011 2.60 / 435.13 2 6
5 13 719.84 31 14.94 1225 567 3.16 / 435.70 2 6
6 13 96.56 31 15.05 397 185 3.35 / 435.88 2 3
7 8 0.08 165 15.02 254 629 3.98 / 436.51 2 5
Average= 3.93
(KJ/cycle)

Cycle 109 GMT 18/ 9/2023 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 32 15.02 391 188 0.19 / 428.78 3 3
2 12 1287.40 3 15.20 2049 93 0.28 / 428.87 2 3
3 7 2002.36 30 14.91 2809 1256 1.54 / 430.13 2 3
4 13 1590.64 31 14.85 2317 1067 2.60 / 431.19 2 6
5 13 656.44 31 14.96 1143 530 3.13 / 431.72 2 4
6 13 88.60 31 15.07 385 180 3.31 / 431.90 2 3
7 8 0.04 165 15.03 254 630 3.94 / 432.53 2 6
Average= 3.93
(KJ/cycle)

Cycle 108 GMT 8/ 9/2023 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 32 15.00 392 188 0.19 / 424.78 3 3
2 12 1297.56 3 15.22 2041 93 0.28 / 424.87 2 4
3 7 2008.56 31 14.92 2819 1304 1.59 / 426.18 2 3
4 13 1592.76 31 14.86 2324 1071 2.66 / 427.25 2 4
5 13 668.72 31 14.98 1156 537 3.19 / 427.78 2 6
6 13 86.92 31 15.08 383 179 3.37 / 427.96 2 5
7 8 -0.04 165 15.05 252 626 4.00 / 428.59 2 10
Average= 3.93
(KJ/cycle)

Cycle 107 GMT 29/ 8/2023 22:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 32 15.01 393 189 0.19 / 420.57 3 3
2 12 1293.28 3 15.21 2053 94 0.28 / 420.66 2 4
3 7 2007.24 30 14.89 2818 1259 1.54 / 421.92 2 6
4 13 1728.56 31 14.82 2480 1139 2.68 / 423.06 2 4
5 13 758.12 31 14.95 1272 590 3.27 / 423.65 2 4
6 13 109.28 31 15.06 417 195 3.46 / 423.84 2 3
7 8 0.04 165 15.03 255 632 4.10 / 424.48 2 6
8 14 0.04 30 15.00 252 113 4.21 / 424.59 3 15
Average= 3.93
(KJ/cycle)

Cycle 106 GMT 20/ 8/2023 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 15.01 392 188 0.19 / 416.61 3 3
2 12 1282.28 3 15.23 2048 94 0.28 / 416.70 2 3
3 7 2003.72 30 14.91 2821 1262 1.54 / 417.96 2 3
4 13 1603.00 31 14.84 2331 1072 2.62 / 419.03 2 4
5 13 659.04 31 14.96 1147 532 3.15 / 419.57 2 4
6 13 90.48 31 15.06 393 183 3.33 / 419.75 2 3
7 8 -0.04 165 15.03 254 630 3.96 / 420.38 2 4
Average= 3.93
(KJ/cycle)

Cycle 105 GMT 10/ 8/2023 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 32 15.01 389 187 0.19 / 412.64 3 3
2 12 1287.28 3 15.22 2034 93 0.28 / 412.73 2 3
3 7 2007.92 30 14.92 2819 1262 1.54 / 414.00 2 8
4 13 1598.60 31 14.87 2326 1072 2.61 / 415.07 2 5
5 13 668.44 31 14.98 1157 537 3.15 / 415.61 2 6
6 13 90.60 31 15.07 389 182 3.33 / 415.79 2 4
7 8 -0.04 165 15.05 254 631 3.96 / 416.42 3 7
Average= 3.93
(KJ/cycle)

Cycle 104 GMT 31/ 7/2023 5:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 32 15.01 394 189 0.19 / 408.67 3 3
2 12 1302.76 3 15.24 2058 94 0.28 / 408.77 2 3
3 7 2006.16 30 14.90 2821 1261 1.54 / 410.03 2 6
4 13 1601.76 31 14.85 2324 1070 2.61 / 411.10 2 4
5 13 675.48 31 14.97 1166 541 3.16 / 411.64 2 4
6 13 89.72 31 15.07 390 182 3.34 / 411.82 2 3
7 8 0.00 165 15.04 255 633 3.97 / 412.46 2 8
Average= 3.93
(KJ/cycle)

Cycle 103 GMT 21/ 7/2023 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 32 14.99 389 187 0.19 / 404.69 3 3
2 12 1274.36 3 15.23 2037 93 0.28 / 404.79 2 3
3 7 2002.72 30 14.93 2825 1265 1.54 / 406.05 2 3
4 13 1602.88 31 14.87 2335 1076 2.62 / 407.13 2 4
5 13 684.00 31 14.97 1179 547 3.17 / 407.68 2 4
6 13 98.20 31 15.08 398 186 3.35 / 407.86 2 3
7 8 -0.04 165 15.05 251 623 3.98 / 408.48 2 10
Average= 3.93
(KJ/cycle)

Cycle 102 GMT 11/ 7/2023 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 32 14.98 400 192 0.19 / 400.74 3 3
2 12 1283.00 3 15.23 2023 92 0.28 / 400.83 2 4
3 7 2004.44 30 14.92 2824 1264 1.55 / 402.09 2 4
4 13 1593.92 31 14.86 2321 1069 2.62 / 403.16 2 8
5 13 653.12 31 14.98 1139 529 3.15 / 403.69 2 6
6 13 93.36 31 15.07 394 184 3.33 / 403.88 2 4
7 8 0.08 165 15.04 254 630 3.96 / 404.51 2 6
Average= 3.93
(KJ/cycle)

Cycle 101 GMT 1/ 7/2023 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 32 15.01 407 195 0.20 / 396.62 3 3
2 12 1291.36 3 15.23 2060 94 0.29 / 396.72 2 3
3 7 2007.76 31 14.93 2818 1304 1.59 / 398.02 2 5
4 13 1609.76 31 14.85 2341 1078 2.67 / 399.10 2 7
5 13 806.08 31 14.94 1337 619 3.29 / 399.72 2 6
6 13 115.48 31 15.06 425 198 3.49 / 399.92 2 3
7 8 -0.12 165 15.04 254 630 4.12 / 400.55 2 6
Average= 3.93
(KJ/cycle)

Cycle 100 GMT 21/ 6/2023 13:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 32 15.00 398 191 0.19 / 392.52 3 3
2 12 1306.44 3 15.22 2076 95 0.29 / 392.61 2 3
3 7 2002.04 30 14.92 2815 1260 1.55 / 393.87 2 3
4 13 1723.04 31 14.85 2470 1137 2.68 / 395.01 2 9
5 13 760.52 31 14.95 1275 591 3.27 / 395.60 2 3
6 13 107.56 31 15.06 414 193 3.47 / 395.79 2 3
7 8 0.04 165 15.04 256 635 4.10 / 396.43 2 4
Average= 3.93
(KJ/cycle)

Cycle 99 GMT 11/ 6/2023 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 32 15.02 391 188 0.19 / 388.55 3 3
2 12 1289.08 3 15.24 2060 94 0.28 / 388.65 2 3
3 7 2003.80 30 14.92 2820 1262 1.54 / 389.91 2 4
4 13 1598.96 31 14.86 2326 1071 2.62 / 390.98 2 6
5 13 665.44 31 14.97 1152 535 3.15 / 391.52 2 4
6 13 95.72 31 15.06 394 184 3.33 / 391.70 2 5
7 8 0.04 165 15.04 252 625 3.96 / 392.32 2 5
Average= 3.92
(KJ/cycle)

Cycle 98 GMT 1/ 6/2023 18:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 32 15.03 388 187 0.19 / 384.57 3 3
2 12 1309.64 3 15.22 2064 94 0.28 / 384.66 2 4
3 7 2010.08 30 14.93 2833 1269 1.55 / 385.93 2 3
4 13 1609.96 31 14.87 2342 1080 2.63 / 387.01 2 7
5 13 683.28 31 14.98 1175 546 3.17 / 387.55 2 3
6 13 93.08 31 15.07 394 184 3.36 / 387.74 2 2
7 8 0.08 165 15.05 252 626 3.98 / 388.36 2 3
Average= 3.92
(KJ/cycle)

Cycle 97 GMT 22/ 5/2023 20:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 32 14.99 396 190 0.19 / 380.58 3 3
2 12 1304.60 3 15.22 2054 94 0.28 / 380.67 2 5
3 7 2002.16 31 14.91 2818 1303 1.59 / 381.98 2 3
4 13 1589.36 31 14.86 2317 1067 2.65 / 383.04 2 5
5 13 651.92 31 14.98 1136 528 3.18 / 383.57 2 4
6 13 85.08 31 15.08 382 179 3.36 / 383.75 2 3
7 8 -0.08 165 15.06 254 631 3.99 / 384.38 2 6
Average= 3.92
(KJ/cycle)

Cycle 96 GMT 12/ 5/2023 22:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 32 15.01 391 188 0.19 / 376.51 3 3
2 12 1298.36 3 15.23 2041 93 0.28 / 376.61 2 5
3 7 2005.64 30 14.93 2815 1261 1.54 / 377.87 2 3
4 13 1597.44 31 14.87 2331 1075 2.62 / 378.94 2 5
5 13 810.64 31 14.95 1341 621 3.24 / 379.57 2 7
6 13 106.08 31 15.08 408 191 3.43 / 379.76 2 4
7 8 0.08 165 15.05 255 633 4.06 / 380.39 2 3
Average= 3.92
(KJ/cycle)

Cycle 95 GMT 3/ 5/2023 0:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 32 15.03 394 189 0.19 / 372.55 3 3
2 12 1312.56 3 15.21 2075 95 0.28 / 372.64 2 4
3 7 2009.72 30 14.91 2826 1264 1.55 / 373.91 2 3
4 13 1604.84 31 14.86 2334 1075 2.62 / 374.98 2 4
5 13 661.72 31 14.97 1145 531 3.15 / 375.51 2 4
6 13 98.36 31 15.07 398 186 3.34 / 375.70 2 3
7 8 0.08 165 15.05 253 628 3.97 / 376.33 3 3
Average= 3.92
(KJ/cycle)

Cycle 94 GMT 23/ 4/2023 2:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 32 15.03 386 186 0.19 / 368.58 3 3
2 12 1299.48 3 15.23 2061 94 0.28 / 368.68 2 3
3 7 2006.28 30 14.94 2822 1265 1.54 / 369.94 2 3
4 13 1591.84 31 14.86 2317 1067 2.61 / 371.01 2 5
5 13 662.84 31 14.99 1148 533 3.15 / 371.54 2 4
6 13 93.24 31 15.07 394 184 3.33 / 371.73 2 4
7 8 0.00 165 15.05 254 631 3.96 / 372.36 2 4
Average= 3.92
(KJ/cycle)

Cycle 93 GMT 13/ 4/2023 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 32 15.04 397 191 0.19 / 364.61 3 3
2 12 1310.24 3 15.23 2091 96 0.29 / 364.71 2 3
3 7 2007.68 30 14.91 2823 1263 1.55 / 365.97 2 5
4 13 1605.60 31 14.86 2344 1080 2.63 / 367.05 2 6
5 13 653.52 31 14.99 1140 530 3.16 / 367.58 2 3
6 13 84.36 31 15.07 387 181 3.34 / 367.76 2 5
7 8 -0.12 165 15.06 256 636 3.98 / 368.40 2 7
Average= 3.92
(KJ/cycle)

Cycle 92 GMT 3/ 4/2023 7: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 32 15.02 395 190 0.19 / 360.56 3 3
2 12 1283.64 3 15.23 2032 93 0.28 / 360.65 2 4
3 7 2004.28 31 14.94 2829 1310 1.59 / 361.96 2 5
4 13 1723.52 31 14.85 2481 1142 2.74 / 363.10 2 5
5 13 614.00 31 15.01 1092 508 3.24 / 363.61 2 4
6 13 90.04 31 15.10 387 181 3.42 / 363.79 2 3
7 8 -0.04 165 15.07 254 632 4.06 / 364.42 3 5
Average= 3.92
(KJ/cycle)

Cycle 91 GMT 24/ 3/2023 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 32 15.04 390 188 0.19 / 356.53 3 3
2 12 1309.76 3 15.21 2071 94 0.28 / 356.63 2 3
3 7 2004.68 30 14.91 2809 1256 1.54 / 357.88 2 4
4 13 1579.88 31 14.87 2303 1062 2.60 / 358.95 2 4
5 13 780.12 31 14.96 1302 604 3.20 / 359.55 2 6
6 13 73.08 31 15.08 376 176 3.38 / 359.73 2 3
7 8 0.08 165 15.06 258 641 4.02 / 360.37 2 6
Average= 3.92
(KJ/cycle)

Cycle 90 GMT 14/ 3/2023 11:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 32 15.04 397 191 0.19 / 352.50 3 3
2 12 1290.80 3 15.22 2048 94 0.28 / 352.59 2 3
3 7 2006.56 30 14.93 2827 1266 1.55 / 353.86 2 3
4 13 1593.72 31 14.86 2321 1069 2.62 / 354.92 2 4
5 13 785.76 31 14.96 1310 608 3.23 / 355.53 2 5
6 13 93.36 31 15.08 394 184 3.41 / 355.72 2 4
7 8 0.08 165 15.07 253 629 4.04 / 356.35 2 9
Average= 3.92
(KJ/cycle)

Cycle 89 GMT 4/ 3/2023 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 32 15.03 398 191 0.19 / 348.53 3 3
2 12 1300.84 3 15.23 2073 95 0.29 / 348.63 2 4
3 7 2004.28 30 14.94 2818 1263 1.55 / 349.89 2 4
4 13 1603.56 31 14.86 2329 1073 2.62 / 350.96 2 7
5 13 649.48 31 15.00 1131 526 3.15 / 351.49 2 4
6 13 105.96 31 15.08 409 191 3.34 / 351.68 2 3
7 8 0.04 165 15.05 252 626 3.96 / 352.30 2 8
Average= 3.91
(KJ/cycle)

Cycle 88 GMT 22/ 2/2023 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 15.04 392 189 0.19 / 344.39 3 3
2 12 1278.80 3 15.24 2025 93 0.28 / 344.48 2 6
3 7 2006.84 30 14.93 2819 1263 1.54 / 345.75 2 4
4 13 1581.40 31 14.89 2311 1067 2.61 / 346.81 2 5
5 13 769.64 31 14.97 1289 598 3.21 / 347.41 2 3
6 13 78.24 31 15.09 380 178 3.39 / 347.59 2 8
7 8 0.00 165 15.07 256 637 4.02 / 348.22 2 3
8 14 0.00 30 15.05 255 115 4.14 / 348.34 3 5
Average= 3.91
(KJ/cycle)

Cycle 87 GMT 12/ 2/2023 17:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 32 15.03 391 188 0.19 / 340.46 3 5
2 12 1334.16 3 15.23 2101 96 0.28 / 340.56 2 3
3 7 2001.68 30 14.92 2816 1260 1.54 / 341.82 2 6
4 13 1569.48 31 14.88 2289 1056 2.60 / 342.87 2 5
5 13 648.04 31 15.00 1127 524 3.12 / 343.40 2 5
6 13 67.04 31 15.11 363 170 3.29 / 343.57 2 3
7 8 0.08 165 15.07 255 634 3.93 / 344.20 3 4
Average= 3.91
(KJ/cycle)

Cycle 86 GMT 2/ 2/2023 20: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 32 15.04 391 188 0.19 / 336.50 3 3
2 12 1289.24 3 15.24 2045 93 0.28 / 336.59 2 4
3 7 2004.96 30 14.95 2823 1266 1.55 / 337.86 2 3
4 13 1595.52 31 14.87 2318 1069 2.62 / 338.93 2 4
5 13 659.20 31 14.99 1145 532 3.15 / 339.46 2 3
6 13 76.04 31 15.10 373 175 3.32 / 339.64 2 5
7 8 -0.16 165 15.07 256 637 3.96 / 340.27 2 4
Average= 3.91
(KJ/cycle)

Cycle 85 GMT 23/ 1/2023 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 31 15.04 398 186 0.19 / 332.22 3 3
2 12 1295.92 3 15.25 2066 95 0.28 / 332.31 2 3
3 7 2004.40 30 14.94 2820 1264 1.54 / 333.57 2 4
4 13 1727.08 31 14.87 2483 1145 2.69 / 334.72 2 5
5 13 870.64 31 14.96 1414 656 3.34 / 335.38 2 5
6 13 94.64 31 15.11 396 185 3.53 / 335.56 2 3
7 8 0.00 165 15.09 256 637 4.17 / 336.20 3 7
8 14 0.00 30 15.06 255 115 4.28 / 336.31 3 27
Average= 3.91
(KJ/cycle)

Cycle 84 GMT 14/ 1/2023 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 31 15.05 396 185 0.18 / 328.28 3 3
2 12 1290.68 3 15.23 2045 93 0.28 / 328.38 2 3
3 7 2006.44 30 14.94 2823 1265 1.54 / 329.64 2 5
4 13 1575.28 31 14.89 2287 1056 2.60 / 330.70 2 9
5 13 645.92 31 15.01 1126 524 3.12 / 331.22 2 4
6 13 70.44 31 15.11 362 170 3.29 / 331.39 2 3
7 8 0.00 165 15.08 257 639 3.93 / 332.03 2 5
Average= 3.91
(KJ/cycle)

Cycle 83 GMT 4/ 1/2023 3: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 31 15.07 400 187 0.19 / 324.28 3 3
2 12 1324.80 3 15.24 2089 96 0.28 / 324.38 2 4
3 7 2002.68 30 14.94 2818 1263 1.55 / 325.64 2 5
4 13 1575.16 31 14.89 2299 1061 2.61 / 326.70 2 6
5 13 757.64 31 15.00 1279 595 3.20 / 327.29 2 5
6 13 53.76 31 15.12 345 162 3.36 / 327.46 2 3
7 8 -0.08 165 15.10 258 643 4.01 / 328.10 2 3
Average= 3.91
(KJ/cycle)

Cycle 82 GMT 25/12/2022 5:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 31 15.07 392 183 0.18 / 320.21 3 3
2 12 1305.88 3 15.25 2074 95 0.28 / 320.30 2 3
3 7 2004.52 30 14.94 2815 1262 1.54 / 321.57 2 9
4 13 1721.64 31 14.88 2473 1141 2.68 / 322.71 2 4
5 13 743.48 31 15.01 1254 583 3.26 / 323.29 2 6
6 13 54.40 31 15.13 347 163 3.43 / 323.45 2 7
7 8 0.04 165 15.10 257 640 4.07 / 324.09 2 8
Average= 3.90
(KJ/cycle)

Cycle 81 GMT 15/12/2022 7:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 31 15.06 393 183 0.18 / 316.36 3 3
2 12 1326.12 3 15.25 2099 96 0.28 / 316.46 2 4
3 7 2006.00 30 14.93 2827 1266 1.55 / 317.72 2 3
4 13 1480.00 31 14.90 2185 1009 2.55 / 318.73 2 8
5 13 576.52 31 15.05 1038 484 3.04 / 319.22 2 4
6 13 47.52 31 15.13 339 159 3.20 / 319.38 2 4
7 8 -0.08 165 15.09 261 650 3.85 / 320.03 2 7
Average= 3.90
(KJ/cycle)

Cycle 80 GMT 5/12/2022 9:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 31 15.07 396 185 0.18 / 312.40 3 3
2 12 1305.36 3 15.24 2085 95 0.28 / 312.49 2 4
3 7 2004.76 31 14.95 2819 1306 1.59 / 313.80 2 4
4 13 1491.68 31 14.89 2193 1012 2.60 / 314.81 2 4
5 13 713.76 31 15.01 1215 565 3.16 / 315.38 2 5
6 13 39.32 31 15.13 329 154 3.32 / 315.53 2 6
7 8 -0.08 165 15.10 259 645 3.96 / 316.18 2 3
Average= 3.90
(KJ/cycle)

Cycle 79 GMT 25/11/2022 11:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 31 15.06 391 183 0.18 / 308.46 3 3
2 12 1297.20 3 15.25 2059 94 0.28 / 308.56 2 5
3 7 2004.72 30 14.95 2822 1266 1.54 / 309.82 2 3
4 13 1584.24 31 14.90 2302 1063 2.61 / 310.88 2 6
5 13 640.60 31 15.02 1119 521 3.13 / 311.41 2 5
6 13 53.56 31 15.14 345 162 3.29 / 311.57 2 3
7 8 -0.08 165 15.11 259 646 3.93 / 312.21 2 3
Average= 3.90
(KJ/cycle)

Cycle 78 GMT 15/11/2022 14: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 31 15.09 406 190 0.19 / 304.49 3 3
2 12 1296.08 3 15.24 2062 94 0.28 / 304.58 2 5
3 7 2004.52 30 14.94 2822 1265 1.55 / 305.85 2 3
4 13 1599.72 31 14.89 2326 1074 2.62 / 306.92 2 5
5 13 670.00 31 15.02 1160 540 3.16 / 307.46 2 4
6 13 61.68 31 15.15 358 168 3.33 / 307.63 2 3
7 8 -0.16 165 15.11 261 651 3.98 / 308.28 2 6
Average= 3.90
(KJ/cycle)

Cycle 77 GMT 5/11/2022 15:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 31 15.09 411 192 0.19 / 300.41 3 3
2 12 1300.04 3 15.24 2036 93 0.29 / 300.50 2 5
3 7 2004.68 30 14.95 2817 1263 1.55 / 301.77 2 5
4 13 1606.00 31 14.89 2339 1080 2.63 / 302.85 2 4
5 13 671.00 31 15.02 1162 541 3.17 / 303.39 2 4
6 13 33.56 31 15.16 319 150 3.32 / 303.54 2 3
7 8 -0.04 165 15.11 259 646 3.97 / 304.18 2 3
8 14 -0.04 30 15.09 256 116 4.08 / 304.30 2 5
Average= 3.90
(KJ/cycle)

Cycle 76 GMT 26/10/2022 17:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 31 15.09 389 182 0.18 / 296.44 3 3
2 12 1295.68 3 15.25 2063 94 0.28 / 296.53 2 3
3 7 2005.88 30 14.97 2823 1268 1.54 / 297.80 2 5
4 13 1598.12 31 14.91 2327 1076 2.62 / 298.88 2 4
5 13 660.32 31 15.03 1147 534 3.15 / 299.41 2 5
6 13 37.24 31 15.16 325 153 3.31 / 299.57 2 3
7 8 0.00 165 15.13 261 652 3.96 / 300.22 2 4
Average= 3.90
(KJ/cycle)

Cycle 75 GMT 16/10/2022 19:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 31 15.10 393 184 0.18 / 292.41 3 3
2 12 1296.08 3 15.25 2075 95 0.28 / 292.50 2 5
3 7 2002.12 30 14.95 2813 1262 1.54 / 293.76 2 7
4 13 1590.88 31 14.90 2318 1071 2.61 / 294.83 2 4
5 13 799.60 31 14.99 1328 617 3.23 / 295.45 2 5
6 13 49.76 31 15.15 340 160 3.39 / 295.61 2 3
7 8 -0.08 165 15.12 260 649 4.04 / 296.26 2 3
Average= 3.90
(KJ/cycle)

Cycle 74 GMT 6/10/2022 22:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 31 15.08 404 189 0.19 / 288.40 3 3
2 12 1298.68 3 15.25 2067 95 0.28 / 288.49 2 4
3 7 2005.76 31 14.96 2824 1310 1.59 / 289.80 2 4
4 13 1501.28 31 14.92 2208 1021 2.61 / 290.82 2 6
5 13 718.32 31 15.03 1225 571 3.19 / 291.39 2 5
6 13 83.48 31 15.16 388 182 3.37 / 291.57 2 3
7 8 -0.12 165 15.13 259 647 4.01 / 292.22 2 4
Average= 3.90
(KJ/cycle)

Cycle 73 GMT 27/ 9/2022 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 31 15.10 401 188 0.19 / 284.38 3 3
2 12 1298.28 3 15.26 2058 94 0.28 / 284.47 2 4
3 7 2007.52 30 14.96 2832 1271 1.55 / 285.74 2 3
4 13 1603.88 31 14.90 2341 1081 2.63 / 286.82 2 4
5 13 666.88 31 15.04 1160 541 3.18 / 287.36 2 7
6 13 75.08 31 15.16 380 179 3.35 / 287.54 2 2
7 8 -0.08 165 15.12 267 666 4.02 / 288.21 2 3
Average= 3.89
(KJ/cycle)

Cycle 72 GMT 17/ 9/2022 2:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 31 15.08 390 182 0.18 / 280.39 3 3
2 12 1301.60 3 15.26 2076 95 0.28 / 280.48 2 5
3 7 2003.88 30 14.95 2820 1265 1.54 / 281.75 2 6
4 13 1607.20 31 14.90 2333 1078 2.62 / 282.83 2 5
5 13 660.36 31 15.04 1149 536 3.16 / 283.36 2 4
6 13 69.40 31 15.16 371 174 3.33 / 283.54 2 3
7 8 -0.12 165 15.13 261 652 3.98 / 284.19 2 4
Average= 3.89
(KJ/cycle)

Cycle 71 GMT 7/ 9/2022 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 15.10 399 187 0.19 / 276.37 3 3
2 12 1295.00 3 15.25 2072 95 0.28 / 276.46 2 5
3 7 2005.64 31 14.96 2822 1309 1.59 / 277.77 2 3
4 13 1595.80 31 14.90 2323 1073 2.66 / 278.85 2 9
5 13 660.16 31 15.05 1148 536 3.20 / 279.38 2 4
6 13 78.84 31 15.17 383 180 3.38 / 279.56 2 3
7 8 -0.04 165 15.13 258 644 4.02 / 280.21 2 5
Average= 3.89
(KJ/cycle)

Cycle 70 GMT 28/ 8/2022 6:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 31 15.11 402 188 0.19 / 272.44 3 3
2 12 1161.64 3 15.30 1876 86 0.27 / 272.53 2 4
3 7 2007.64 30 14.96 2817 1264 1.54 / 273.79 2 3
4 13 1481.00 31 14.92 2177 1007 2.55 / 274.80 2 7
5 13 702.16 31 15.04 1201 560 3.11 / 275.36 2 4
6 13 83.96 31 15.16 388 182 3.29 / 275.54 2 3
7 8 -0.12 165 15.13 258 644 3.93 / 276.18 3 4
Average= 3.89
(KJ/cycle)

Cycle 69 GMT 18/ 8/2022 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 31 15.11 395 185 0.19 / 268.43 3 3
2 12 1309.92 3 15.27 2077 95 0.28 / 268.53 2 4
3 7 2007.08 30 14.98 2826 1270 1.55 / 269.80 2 5
4 13 1611.12 31 14.90 2339 1080 2.63 / 270.88 2 3
5 13 690.32 31 15.05 1180 551 3.18 / 271.43 2 5
6 13 86.08 31 15.18 386 182 3.36 / 271.61 2 3
7 8 -0.04 165 15.14 256 640 4.00 / 272.25 3 5
Average= 3.89
(KJ/cycle)

Cycle 68 GMT 8/ 8/2022 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 31 15.12 393 184 0.18 / 264.48 3 3
2 12 1309.20 3 15.29 2055 94 0.28 / 264.57 2 6
3 7 2006.68 30 14.96 2812 1262 1.54 / 265.83 2 5
4 13 1600.44 31 14.91 2327 1076 2.62 / 266.91 2 7
5 13 654.68 31 15.06 1132 528 3.14 / 267.44 2 5
6 13 78.24 31 15.18 374 176 3.32 / 267.61 2 3
7 8 0.04 165 15.14 254 635 3.96 / 268.25 2 7
Average= 3.89
(KJ/cycle)

Cycle 67 GMT 29/ 7/2022 12:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 31 15.11 395 185 0.19 / 260.52 3 3
2 12 1290.52 3 15.27 2054 94 0.28 / 260.61 2 3
3 7 2008.60 30 14.96 2815 1263 1.54 / 261.88 2 5
4 13 1601.36 31 14.92 2332 1079 2.62 / 262.95 2 9
5 13 666.96 31 15.06 1153 538 3.16 / 263.49 2 4
6 13 74.52 31 15.18 372 175 3.33 / 263.67 2 4
7 8 -0.08 165 15.14 251 627 3.96 / 264.29 2 5
Average= 3.89
(KJ/cycle)

Cycle 66 GMT 19/ 7/2022 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 31 15.11 390 183 0.18 / 256.48 3 3
2 12 1158.12 3 15.31 1889 87 0.27 / 256.56 2 4
3 7 2002.92 30 14.98 2825 1270 1.54 / 257.83 2 3
4 13 1600.16 31 14.92 2326 1076 2.61 / 258.91 2 7
5 13 779.80 31 15.04 1304 608 3.22 / 259.52 2 5
6 13 69.08 31 15.17 368 173 3.40 / 259.69 2 3
7 8 -0.08 165 15.16 257 643 4.04 / 260.33 2 5
Average= 3.89
(KJ/cycle)

Cycle 65 GMT 9/ 7/2022 17: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 31 15.12 391 183 0.18 / 252.52 3 3
2 12 1316.64 3 15.26 2081 95 0.28 / 252.62 2 4
3 7 2002.16 30 14.97 2826 1269 1.55 / 253.89 2 3
4 13 1580.00 31 14.92 2302 1065 2.61 / 254.95 2 6
5 13 645.08 31 15.07 1129 527 3.14 / 255.48 2 8
6 13 69.28 31 15.18 368 173 3.31 / 255.65 2 3
7 8 0.00 165 15.15 256 640 3.95 / 256.29 3 4
Average= 3.88
(KJ/cycle)

Cycle 64 GMT 29/ 6/2022 19: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 31 15.14 396 186 0.19 / 248.55 3 3
2 12 1300.96 3 15.28 2062 95 0.28 / 248.65 2 3
3 7 2002.32 30 14.96 2813 1262 1.54 / 249.91 2 4
4 13 1588.48 31 14.92 2309 1068 2.61 / 250.98 2 5
5 13 647.52 31 15.07 1127 527 3.14 / 251.50 2 4
6 13 69.28 31 15.19 376 177 3.31 / 251.68 2 6
7 8 -0.04 165 15.15 264 660 3.97 / 252.34 2 3
Average= 3.88
(KJ/cycle)

Cycle 63 GMT 19/ 6/2022 21:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 31 15.15 392 184 0.18 / 244.42 3 3
2 12 1329.36 3 15.25 2110 97 0.28 / 244.52 2 3
3 7 2006.48 31 14.96 2818 1307 1.59 / 245.82 2 9
4 13 1737.12 31 14.90 2492 1151 2.74 / 246.97 2 5
5 13 746.36 31 15.05 1255 586 3.32 / 247.56 2 4
6 13 65.04 31 15.18 359 169 3.49 / 247.73 2 3
7 8 0.12 165 15.15 255 637 4.13 / 248.37 2 7
Average= 3.88
(KJ/cycle)

Cycle 62 GMT 9/ 6/2022 23:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 31 15.14 401 188 0.19 / 240.41 3 3
2 12 1313.76 3 15.27 2068 95 0.28 / 240.50 2 3
3 7 2003.32 30 14.97 2822 1267 1.55 / 241.77 2 6
4 13 1715.60 31 14.90 2476 1144 2.69 / 242.91 2 3
5 13 613.92 31 15.10 1083 507 3.20 / 243.42 2 5
6 13 68.76 31 15.21 367 173 3.37 / 243.59 2 3
7 8 0.00 165 15.17 257 643 4.02 / 244.24 2 10
Average= 3.88
(KJ/cycle)

Cycle 61 GMT 31/ 5/2022 1:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 31 15.13 402 189 0.19 / 236.32 3 3
2 12 1279.24 3 15.29 2047 94 0.28 / 236.41 2 3
3 7 2004.40 31 14.98 2821 1310 1.59 / 237.72 2 3
4 13 1592.00 31 14.93 2320 1074 2.67 / 238.80 2 7
5 13 783.80 31 15.05 1307 610 3.28 / 239.41 2 4
6 13 63.84 31 15.20 356 168 3.44 / 239.57 2 2
7 8 0.04 165 15.16 258 645 4.09 / 240.22 2 9
Average= 3.87
(KJ/cycle)

Cycle 60 GMT 21/ 5/2022 3:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 31 15.15 398 187 0.19 / 232.29 3 3
2 12 1166.88 3 15.32 1886 87 0.27 / 232.38 2 3
3 7 2002.36 31 14.97 2825 1311 1.58 / 233.69 2 7
4 13 1595.16 31 14.93 2323 1075 2.66 / 234.77 2 9
5 13 675.60 31 15.08 1168 546 3.21 / 235.31 2 3
6 13 77.08 31 15.19 378 178 3.38 / 235.49 2 3
7 8 -0.08 165 15.17 255 638 4.02 / 236.13 2 5
Average= 3.87
(KJ/cycle)

Cycle 59 GMT 11/ 5/2022 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 31 15.15 399 187 0.19 / 228.30 3 3
2 12 1295.76 3 15.27 2071 95 0.28 / 228.40 2 5
3 7 2003.12 30 14.99 2823 1270 1.55 / 229.67 2 5
4 13 1600.72 31 14.94 2341 1084 2.64 / 230.75 2 5
5 13 650.68 31 15.11 1137 533 3.17 / 231.28 2 3
6 13 84.68 31 15.22 386 182 3.35 / 231.46 2 4
7 8 0.00 165 15.18 257 644 3.99 / 232.11 2 6
Average= 3.87
(KJ/cycle)

Cycle 58 GMT 1/ 5/2022 7:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 31 15.17 395 186 0.19 / 224.33 3 3
2 12 1310.60 3 15.28 2105 96 0.28 / 224.42 2 6
3 7 2001.44 30 14.99 2819 1268 1.55 / 225.69 2 4
4 13 1591.24 31 14.94 2316 1073 2.62 / 226.76 2 6
5 13 656.40 31 15.10 1143 535 3.16 / 227.30 2 4
6 13 71.60 31 15.21 370 174 3.33 / 227.47 2 3
7 8 0.04 165 15.19 256 642 3.97 / 228.11 2 4
Average= 3.87
(KJ/cycle)

Cycle 57 GMT 21/ 4/2022 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 15.16 398 187 0.19 / 220.37 3 3
2 12 1293.28 3 15.30 2069 95 0.28 / 220.46 2 3
3 7 2005.92 30 14.98 2827 1270 1.55 / 221.74 2 5
4 13 1599.76 31 14.93 2328 1077 2.63 / 222.81 2 6
5 13 624.28 31 15.10 1099 514 3.14 / 223.33 2 7
6 13 72.48 31 15.21 369 174 3.32 / 223.50 2 3
7 8 0.04 165 15.18 255 639 3.96 / 224.14 2 4
Average= 3.86
(KJ/cycle)

Cycle 56 GMT 11/ 4/2022 11:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 31 15.16 394 185 0.19 / 216.29 3 3
2 12 1299.56 3 15.27 2052 94 0.28 / 216.38 2 4
3 7 2003.88 30 14.98 2820 1267 1.55 / 217.65 2 3
4 13 1728.76 31 14.93 2490 1152 2.70 / 218.80 2 4
5 13 727.08 31 15.08 1230 575 3.27 / 219.37 2 4
6 13 69.96 31 15.21 363 171 3.45 / 219.55 2 3
7 8 0.12 165 15.19 254 637 4.08 / 220.18 2 6
Average= 3.86
(KJ/cycle)

Cycle 55 GMT 1/ 4/2022 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 31 15.16 389 183 0.18 / 212.25 3 3
2 12 1295.92 3 15.30 2061 95 0.28 / 212.34 2 3
3 7 2003.76 30 14.99 2828 1272 1.55 / 213.61 2 3
4 13 1593.36 31 14.94 2330 1079 2.63 / 214.69 2 4
5 13 773.48 31 15.07 1290 603 3.23 / 215.30 2 6
6 13 67.60 31 15.23 362 171 3.40 / 215.47 2 3
7 8 -0.04 165 15.20 253 635 4.04 / 216.10 2 3
Average= 3.86
(KJ/cycle)

Cycle 54 GMT 22/ 3/2022 16:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 30 15.16 396 180 0.18 / 208.27 3 3
2 12 1288.64 3 15.30 2056 94 0.27 / 208.37 2 3
3 7 2004.40 30 15.00 2834 1275 1.55 / 209.64 2 3
4 13 1602.00 31 14.94 2342 1085 2.63 / 210.73 2 5
5 13 655.92 31 15.11 1137 533 3.17 / 211.26 2 3
6 13 70.96 31 15.22 365 172 3.34 / 211.43 2 3
7 8 -0.08 165 15.20 253 635 3.97 / 212.06 2 4
Average= 3.86
(KJ/cycle)

Cycle 53 GMT 12/ 3/2022 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 30 15.17 392 178 0.18 / 204.29 3 3
2 12 1299.28 3 15.30 2059 95 0.27 / 204.39 2 3
3 7 2002.92 30 14.99 2828 1272 1.54 / 205.66 2 7
4 13 1608.44 31 14.95 2339 1084 2.63 / 206.74 2 3
5 13 662.68 31 15.10 1149 538 3.17 / 207.28 2 3
6 13 76.64 31 15.22 372 176 3.34 / 207.46 2 3
7 8 0.08 165 15.19 253 634 3.98 / 208.09 2 5
Average= 3.85
(KJ/cycle)

Cycle 52 GMT 2/ 3/2022 20: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 30 15.16 391 178 0.18 / 200.34 3 3
2 12 1298.52 3 15.29 2055 94 0.27 / 200.44 2 3
3 7 2002.12 30 15.00 2819 1269 1.54 / 201.71 2 4
4 13 1590.36 31 14.94 2317 1073 2.61 / 202.78 2 6
5 13 640.60 31 15.11 1122 526 3.14 / 203.30 2 7
6 13 62.52 31 15.23 357 169 3.31 / 203.47 2 3
7 8 0.04 165 15.20 256 642 3.95 / 204.11 2 6
Average= 3.85
(KJ/cycle)

Cycle 51 GMT 20/ 2/2022 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 30 15.18 388 177 0.18 / 196.38 3 3
2 12 1313.60 3 15.31 2075 95 0.27 / 196.47 2 4
3 7 2004.24 30 15.00 2834 1275 1.55 / 197.75 2 4
4 13 1593.20 31 14.95 2324 1077 2.62 / 198.82 2 6
5 13 646.04 31 15.12 1133 531 3.16 / 199.35 2 5
6 13 59.40 31 15.24 357 169 3.32 / 199.52 2 3
7 8 -0.08 165 15.20 256 642 3.97 / 200.16 2 4
Average= 3.85
(KJ/cycle)

Cycle 50 GMT 11/ 2/2022 0: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 30 15.18 391 178 0.18 / 192.42 3 3
2 12 1317.32 3 15.29 2080 95 0.27 / 192.52 2 4
3 7 2004.00 30 14.99 2826 1271 1.54 / 193.79 2 5
4 13 1588.60 31 14.95 2316 1073 2.62 / 194.86 2 9
5 13 646.08 31 15.12 1129 529 3.15 / 195.39 2 4
6 13 62.48 31 15.23 358 169 3.32 / 195.56 2 3
7 8 -0.04 165 15.22 255 640 3.96 / 196.20 2 6
Average= 3.85
(KJ/cycle)

Cycle 49 GMT 1/ 2/2022 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 30 15.19 394 180 0.18 / 188.34 3 3
2 12 1303.52 3 15.33 2073 95 0.27 / 188.43 2 3
3 7 2005.36 30 15.00 2822 1270 1.54 / 189.70 2 5
4 13 1596.48 31 14.96 2329 1080 2.62 / 190.78 2 5
5 13 641.28 31 15.13 1124 527 3.15 / 191.31 2 7
6 13 64.64 31 15.26 363 172 3.32 / 191.48 2 3
7 8 0.00 165 15.22 256 643 3.97 / 192.13 2 4
8 14 0.00 30 15.19 255 116 4.08 / 192.24 2 5
Average= 3.84
(KJ/cycle)

Cycle 48 GMT 22/ 1/2022 4: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 30 15.19 400 182 0.18 / 184.38 3 3
2 12 1313.40 3 15.30 2099 96 0.28 / 184.48 2 3
3 7 2006.12 30 15.01 2840 1279 1.56 / 185.76 2 4
4 13 1578.12 31 14.97 2308 1071 2.63 / 186.83 2 5
5 13 623.08 31 15.14 1103 518 3.15 / 187.34 2 7
6 13 60.60 31 15.25 358 169 3.32 / 187.51 2 3
7 8 -0.04 165 15.22 257 645 3.96 / 188.16 2 4
Average= 3.84
(KJ/cycle)

Cycle 47 GMT 12/ 1/2022 6:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 15.20 398 181 0.18 / 180.30 3 3
2 12 1297.80 3 15.31 2067 95 0.28 / 180.40 2 3
3 7 2003.12 30 15.00 2831 1274 1.55 / 181.67 2 4
4 13 1593.96 31 14.96 2329 1080 2.63 / 182.75 2 5
5 13 636.76 31 15.12 1115 523 3.15 / 183.27 2 5
6 13 61.32 31 15.24 358 169 3.32 / 183.44 2 3
7 8 0.04 165 15.22 255 640 3.96 / 184.08 2 5
8 14 0.04 30 15.20 253 115 4.08 / 184.20 3 7
Average= 3.84
(KJ/cycle)

Cycle 46 GMT 2/ 1/2022 8:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 30 15.19 387 176 0.18 / 176.32 3 3
2 12 1306.28 3 15.33 2082 96 0.27 / 176.41 2 3
3 7 2003.52 30 15.01 2836 1277 1.55 / 177.69 2 5
4 13 1599.32 31 14.97 2345 1088 2.64 / 178.78 2 7
5 13 642.00 31 15.15 1132 532 3.17 / 179.31 2 4
6 13 54.96 31 15.27 350 166 3.33 / 179.47 2 3
7 8 0.08 165 15.23 257 646 3.98 / 180.12 2 10
Average= 3.83
(KJ/cycle)

Cycle 45 GMT 23/12/2021 10:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 30 15.21 393 179 0.18 / 172.41 3 3
2 12 1156.32 3 15.34 1878 86 0.27 / 172.49 2 4
3 7 2001.12 31 15.01 2822 1313 1.58 / 173.81 2 4
4 13 1587.92 31 14.97 2320 1077 2.66 / 174.88 2 12
5 13 515.76 31 15.17 964 453 3.11 / 175.34 2 5
6 13 46.28 31 15.27 336 159 3.27 / 175.50 2 3
7 8 0.08 165 15.24 256 644 3.91 / 176.14 2 5
Average= 3.83
(KJ/cycle)

Cycle 44 GMT 13/12/2021 12:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 30 15.20 393 179 0.18 / 168.44 3 3
2 12 1301.80 3 15.31 2080 96 0.27 / 168.54 2 3
3 7 2004.52 30 15.01 2838 1278 1.55 / 169.82 2 5
4 13 1587.28 31 14.98 2316 1076 2.63 / 170.89 2 5
5 13 628.16 31 15.15 1110 521 3.15 / 171.41 2 5
6 13 52.52 31 15.26 347 164 3.31 / 171.58 2 3
7 8 -0.04 165 15.23 259 651 3.96 / 172.23 2 4
Average= 3.83
(KJ/cycle)

Cycle 43 GMT 3/12/2021 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 15.20 392 179 0.18 / 164.48 3 3
2 12 1311.80 3 15.33 2078 96 0.27 / 164.58 2 4
3 7 2003.76 30 15.03 2833 1277 1.55 / 165.85 2 4
4 13 1580.24 31 14.98 2306 1071 2.62 / 166.92 2 5
5 13 634.64 31 15.16 1113 523 3.15 / 167.45 2 7
6 13 62.40 31 15.26 360 170 3.32 / 167.62 2 3
7 8 -0.04 165 15.23 257 646 3.96 / 168.26 2 4
Average= 3.82
(KJ/cycle)

Cycle 42 GMT 23/11/2021 16:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 30 15.19 404 184 0.18 / 160.50 3 3
2 12 1308.36 3 15.33 2074 95 0.28 / 160.60 2 5
3 7 2002.92 30 15.02 2835 1277 1.56 / 161.88 2 4
4 13 1591.28 31 14.99 2327 1081 2.64 / 162.96 2 6
5 13 642.72 31 15.16 1125 529 3.17 / 163.49 2 4
6 13 55.36 31 15.27 350 166 3.33 / 163.65 2 3
7 8 0.04 165 15.23 259 651 3.98 / 164.30 2 4
Average= 3.82
(KJ/cycle)

Cycle 41 GMT 13/11/2021 18:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 15.22 391 179 0.18 / 156.37 3 3
2 12 1323.60 3 15.32 2107 97 0.28 / 156.47 2 5
3 7 2002.60 31 15.02 2826 1316 1.59 / 157.78 2 5
4 13 1721.44 31 14.95 2489 1154 2.74 / 158.94 2 4
5 13 733.36 31 15.14 1242 583 3.33 / 159.52 2 5
6 13 37.64 31 15.28 324 153 3.48 / 159.67 2 3
7 8 0.08 165 15.24 257 646 4.13 / 160.32 2 5
Average= 3.82
(KJ/cycle)

Cycle 40 GMT 3/11/2021 20:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 30 15.21 408 186 0.19 / 152.40 3 3
2 12 1303.12 3 15.34 2069 95 0.28 / 152.50 2 6
3 7 2001.40 30 15.03 2835 1278 1.56 / 153.78 2 4
4 13 1588.44 31 14.99 2322 1079 2.64 / 154.86 2 5
5 13 634.28 31 15.16 1111 522 3.16 / 155.38 2 7
6 13 44.48 31 15.28 334 158 3.32 / 155.54 2 3
7 8 -0.08 165 15.25 260 654 3.97 / 156.19 2 4
Average= 3.81
(KJ/cycle)

Cycle 39 GMT 24/10/2021 22:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 30 15.22 397 181 0.18 / 148.47 3 3
2 12 1292.72 3 15.33 2096 96 0.28 / 148.57 2 4
3 7 2001.80 30 15.04 2837 1280 1.56 / 149.85 2 3
4 13 1598.56 30 14.99 2333 1049 2.61 / 150.90 2 6
5 13 654.96 30 15.16 1144 520 3.13 / 151.42 2 5
6 13 37.48 30 15.28 324 149 3.28 / 151.57 2 3
7 8 0.00 165 15.24 259 651 3.93 / 152.22 2 5
Average= 3.81
(KJ/cycle)

Cycle 38 GMT 15/10/2021 0:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 30 15.20 394 180 0.18 / 144.56 3 3
2 12 1311.24 3 15.35 2088 96 0.28 / 144.66 2 3
3 7 2002.92 30 15.03 2829 1276 1.55 / 145.93 2 9
4 13 1567.08 30 14.99 2302 1035 2.59 / 146.97 2 8
5 13 626.08 30 15.17 1104 502 3.09 / 147.47 2 7
6 13 52.56 30 15.28 348 160 3.25 / 147.63 2 3
7 8 0.00 165 15.25 263 662 3.91 / 148.29 2 3
Average= 3.80
(KJ/cycle)

Cycle 37 GMT 5/10/2021 2:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 15.21 384 175 0.18 / 140.75 3 3
2 12 1296.60 3 15.34 2067 95 0.27 / 140.85 2 3
3 7 2002.92 30 15.03 2834 1278 1.55 / 142.12 2 5
4 13 1465.88 30 15.01 2177 980 2.53 / 143.10 2 5
5 13 570.08 30 15.20 1035 472 3.00 / 143.58 2 4
6 13 39.76 30 15.28 329 151 3.15 / 143.73 2 3
7 8 0.04 165 15.24 260 654 3.81 / 144.38 2 4
Average= 3.80
(KJ/cycle)

Cycle 36 GMT 25/ 9/2021 4:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 30 15.22 395 180 0.18 / 136.83 3 3
2 12 1295.96 3 15.32 2068 95 0.28 / 136.92 2 3
3 7 2003.48 30 15.03 2836 1279 1.55 / 138.20 2 4
4 13 1584.24 30 14.99 2325 1046 2.60 / 139.25 2 10
5 13 641.00 30 15.18 1128 514 3.11 / 139.76 2 5
6 13 47.96 30 15.30 342 157 3.27 / 139.92 2 3
7 8 -0.08 165 15.25 261 657 3.93 / 140.58 2 5
Average= 3.80
(KJ/cycle)

Cycle 35 GMT 15/ 9/2021 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 15.23 383 175 0.17 / 132.93 3 3
2 12 1301.68 3 15.33 2066 95 0.27 / 133.03 2 3
3 7 2002.00 30 15.01 2831 1275 1.54 / 134.30 2 5
4 13 1574.96 30 15.00 2296 1033 2.58 / 135.34 2 7
5 13 628.32 30 15.17 1110 505 3.08 / 135.84 2 6
6 13 52.20 30 15.28 347 159 3.24 / 136.00 2 3
7 8 -0.04 165 15.25 258 649 3.89 / 136.65 2 5
Average= 3.80
(KJ/cycle)

Cycle 34 GMT 5/ 9/2021 8:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 15.22 393 179 0.18 / 129.12 3 3
2 12 1316.60 3 15.33 2108 97 0.28 / 129.21 2 3
3 7 2003.32 30 15.03 2827 1275 1.55 / 130.49 2 6
4 13 1473.28 30 15.03 2182 984 2.53 / 131.47 2 9
5 13 570.48 30 15.19 1036 472 3.01 / 131.94 2 4
6 13 55.32 30 15.28 350 160 3.17 / 132.11 2 3
7 8 0.04 165 15.25 259 652 3.82 / 132.76 2 6
Average= 3.79
(KJ/cycle)

Cycle 33 GMT 26/ 8/2021 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 30 15.22 389 178 0.18 / 125.15 3 3
2 12 1303.36 3 15.32 2110 97 0.27 / 125.25 2 3
3 7 2003.80 31 15.04 2838 1323 1.60 / 126.57 2 5
4 13 1582.88 30 15.01 2317 1043 2.64 / 127.61 2 3
5 13 637.36 30 15.18 1122 511 3.15 / 128.12 2 4
6 13 63.60 30 15.29 361 166 3.32 / 128.29 2 3
7 8 -0.04 165 15.26 258 650 3.97 / 128.94 2 6
Average= 3.79
(KJ/cycle)

Cycle 32 GMT 16/ 8/2021 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 30 15.22 395 180 0.18 / 121.22 3 3
2 12 1165.96 3 15.36 1895 87 0.27 / 121.31 2 4
3 7 2001.36 30 15.04 2823 1274 1.54 / 122.58 2 6
4 13 1586.80 30 15.01 2322 1046 2.59 / 123.62 2 8
5 13 659.08 30 15.17 1149 523 3.11 / 124.15 2 7
6 13 66.08 30 15.29 367 168 3.28 / 124.32 2 3
7 8 -0.12 165 15.26 260 655 3.93 / 124.97 2 4
Average= 3.79
(KJ/cycle)

Cycle 31 GMT 6/ 8/2021 14: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 30 15.23 398 182 0.18 / 117.29 3 3
2 12 1311.96 3 15.34 2096 96 0.28 / 117.38 2 5
3 7 2001.60 30 15.05 2827 1276 1.55 / 118.66 2 3
4 13 1593.24 30 15.00 2325 1046 2.60 / 119.71 2 3
5 13 642.36 30 15.18 1128 514 3.11 / 120.22 2 6
6 13 70.16 30 15.29 370 170 3.28 / 120.39 2 3
7 8 0.08 165 15.26 257 647 3.93 / 121.04 2 4
Average= 3.78
(KJ/cycle)

Cycle 30 GMT 27/ 7/2021 16: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 30 15.23 391 179 0.18 / 113.34 3 3
2 12 1312.24 3 15.36 2086 96 0.27 / 113.43 2 6
3 7 2003.24 30 15.04 2835 1279 1.55 / 114.71 2 6
4 13 1593.28 30 14.99 2331 1048 2.60 / 115.76 2 4
5 13 665.80 30 15.17 1153 525 3.13 / 116.29 2 5
6 13 71.28 30 15.30 371 170 3.30 / 116.46 2 3
7 8 -0.04 165 15.25 258 649 3.95 / 117.11 2 5
Average= 3.78
(KJ/cycle)

Cycle 29 GMT 17/ 7/2021 18: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 30 15.22 399 182 0.18 / 109.40 3 3
2 12 1326.56 3 15.33 2112 97 0.28 / 109.50 2 8
3 7 2001.88 30 15.04 2833 1278 1.56 / 110.77 2 7
4 13 1585.00 29 15.00 2324 1011 2.57 / 111.78 2 6
5 13 773.08 29 15.15 1297 570 3.14 / 112.35 2 5
6 13 76.36 29 15.29 378 168 3.31 / 112.52 2 3
7 8 0.00 165 15.27 253 637 3.94 / 113.16 2 4
Average= 3.77
(KJ/cycle)

Cycle 28 GMT 7/ 7/2021 20:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 30 15.24 391 179 0.18 / 105.41 3 3
2 12 1325.72 3 15.34 2089 96 0.27 / 105.51 2 7
3 7 2003.52 30 15.04 2836 1280 1.55 / 106.79 2 3
4 13 1566.44 29 15.02 2293 999 2.55 / 107.79 2 6
5 13 634.32 29 15.18 1114 490 3.04 / 108.28 2 7
6 13 80.36 29 15.29 382 169 3.21 / 108.45 2 3
7 13 21.20 29 15.28 291 129 3.34 / 108.57 2 3
8 8 0.04 165 15.25 255 642 3.98 / 109.22 2 6
Average= 3.77
(KJ/cycle)

Cycle 27 GMT 27/ 6/2021 22:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 30 15.24 398 182 0.18 / 101.51 3 3
2 12 1311.72 3 15.36 2093 96 0.28 / 101.61 2 4
3 7 2002.64 31 15.06 2834 1323 1.60 / 102.93 2 3
4 13 1574.76 29 15.03 2313 1008 2.61 / 103.94 2 4
5 13 627.56 29 15.20 1108 488 3.10 / 104.43 2 3
6 13 82.72 29 15.30 384 170 3.27 / 104.60 2 3
7 8 0.12 165 15.27 252 635 3.90 / 105.23 2 5
Average= 3.76
(KJ/cycle)

Cycle 26 GMT 18/ 6/2021 0:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 30 15.24 389 178 0.18 / 97.61 3 3
2 12 1310.12 3 15.36 2109 97 0.28 / 97.71 2 8
3 7 2002.68 30 15.07 2842 1285 1.56 / 98.99 2 4
4 13 1581.76 29 15.04 2320 1012 2.57 / 100.00 2 6
5 13 654.20 29 15.20 1144 504 3.08 / 100.51 2 7
6 13 91.32 29 15.32 400 178 3.25 / 100.68 2 3
7 8 0.08 165 15.27 256 645 3.90 / 101.33 3 6
Average= 3.75
(KJ/cycle)

Cycle 25 GMT 8/ 6/2021 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 30 15.25 402 184 0.18 / 93.81 3 3
2 12 1331.32 3 15.35 2127 98 0.28 / 93.91 2 6
3 7 2003.56 30 15.06 2843 1284 1.57 / 95.19 2 7
4 13 1588.32 27 15.04 2322 943 2.51 / 96.13 2 4
5 13 686.20 27 15.19 1188 487 3.00 / 96.62 2 4
6 13 96.12 27 15.31 407 168 3.16 / 96.79 2 3
7 8 0.08 165 15.29 254 641 3.81 / 97.43 3 4
Average= 3.75
(KJ/cycle)

Cycle 24 GMT 29/ 5/2021 4:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 30 15.27 395 181 0.18 / 89.77 3 3
2 12 1308.04 3 15.36 2090 96 0.28 / 89.87 2 8
3 7 2002.36 31 15.08 2832 1324 1.60 / 91.19 2 3
4 13 1582.76 27 15.04 2319 942 2.54 / 92.13 2 4
5 13 788.04 27 15.18 1322 542 3.08 / 92.67 2 6
6 13 101.96 27 15.31 414 171 3.26 / 92.85 2 3
7 13 55.72 27 15.30 344 142 3.40 / 92.99 2 3
8 8 -0.12 165 15.28 253 638 4.04 / 93.63 3 7
Average= 3.75
(KJ/cycle)

Cycle 23 GMT 19/ 5/2021 6: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 30 15.25 390 178 0.18 / 85.97 3 3
2 12 1311.60 3 15.35 2086 96 0.27 / 86.06 2 5
3 7 2002.28 30 15.06 2828 1278 1.55 / 87.34 2 8
4 13 1592.44 27 15.05 2338 950 2.50 / 88.29 2 7
5 13 673.40 27 15.21 1177 483 2.99 / 88.77 2 6
6 13 92.96 27 15.31 408 169 3.15 / 88.94 2 3
7 8 -0.12 165 15.29 256 646 3.80 / 89.59 3 7
Average= 3.73
(KJ/cycle)

Cycle 22 GMT 9/ 5/2021 7:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 15.26 393 180 0.18 / 82.11 3 3
2 12 1276.12 3 15.38 2037 94 0.27 / 82.21 2 4
3 7 2003.60 30 15.07 2845 1286 1.56 / 83.49 2 3
4 13 1591.84 27 15.05 2336 949 2.51 / 84.44 2 7
5 13 790.28 27 15.18 1322 542 3.05 / 84.98 2 6
6 13 94.56 27 15.32 404 167 3.22 / 85.15 2 3
7 8 0.04 165 15.30 253 639 3.86 / 85.79 2 5
Average= 3.73
(KJ/cycle)

Cycle 21 GMT 29/ 4/2021 9:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 30 15.26 393 180 0.18 / 78.24 3 3
2 12 1282.04 3 15.38 2055 95 0.27 / 78.33 2 4
3 7 2002.64 30 15.08 2838 1284 1.56 / 79.62 2 3
4 13 1587.32 27 15.07 2331 948 2.51 / 80.56 2 9
5 13 808.24 27 15.20 1350 554 3.06 / 81.12 2 5
6 13 91.48 27 15.32 405 168 3.23 / 81.29 2 3
7 8 0.20 165 15.31 256 647 3.88 / 81.93 3 5
Average= 3.72
(KJ/cycle)

Cycle 20 GMT 19/ 4/2021 11:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 30 15.26 405 185 0.19 / 74.08 3 3
2 12 1275.88 3 15.39 2059 95 0.28 / 74.17 2 4
3 7 2001.48 30 15.08 2842 1286 1.57 / 75.46 2 3
4 13 1724.00 40 14.99 2490 1493 3.06 / 76.95 2 7
5 13 352.84 40 15.28 745 455 3.51 / 77.41 2 5
6 8 0.04 165 15.31 258 652 4.17 / 78.06 3 4
Average= 3.72
(KJ/cycle)

Cycle 19 GMT 9/ 4/2021 13: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 30 15.28 412 189 0.19 / 70.19 3 3
2 12 1156.84 2 15.43 1879 58 0.25 / 70.25 2 5
3 7 2002.52 31 15.08 2839 1327 1.57 / 71.57 2 3
4 13 1574.72 28 15.07 2312 976 2.55 / 72.55 2 10
5 13 736.28 28 15.21 1249 532 3.08 / 73.08 2 5
6 13 80.56 28 15.34 384 165 3.25 / 73.25 2 3
7 8 0.16 165 15.30 255 644 3.89 / 73.89 3 5
Average= 3.69
(KJ/cycle)

Cycle 18 GMT 30/ 3/2021 15:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 29 15.26 415 184 0.18 / 66.37 3 3
2 12 1309.68 2 15.39 2089 64 0.25 / 66.43 2 5
3 7 2005.08 31 15.07 2835 1324 1.57 / 67.75 2 3
4 13 1470.64 28 15.09 2192 926 2.50 / 68.68 2 9
5 13 697.84 28 15.22 1205 514 3.01 / 69.19 2 5
6 13 63.52 28 15.35 365 157 3.17 / 69.35 2 3
7 8 0.12 165 15.31 257 649 3.82 / 70.00 2 4
Average= 3.68
(KJ/cycle)

Cycle 17 GMT 20/ 3/2021 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 29 15.26 397 176 0.18 / 62.25 3 3
2 12 1269.56 2 15.41 2043 63 0.24 / 62.31 2 4
3 7 2002.00 31 15.07 2835 1324 1.56 / 63.64 2 3
4 13 1604.20 33 15.04 2344 1163 2.73 / 64.80 2 3
5 13 603.68 33 15.24 1083 545 3.27 / 65.35 2 10
6 13 56.40 33 15.34 354 179 3.45 / 65.53 2 3
7 8 -0.04 165 15.30 260 656 4.11 / 66.18 2 6
Average= 3.68
(KJ/cycle)

Cycle 16 GMT 10/ 3/2021 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 29 15.27 417 185 0.18 / 58.26 3 3
2 12 1306.76 2 15.40 2079 64 0.25 / 58.32 2 9
3 7 2005.12 32 15.07 2851 1375 1.62 / 59.70 2 3
4 13 1434.64 33 15.08 2136 1063 2.69 / 60.76 2 8
5 13 499.00 33 15.23 943 474 3.16 / 61.23 2 8
6 13 53.48 33 15.34 352 178 3.34 / 61.41 2 3
7 8 -0.28 165 15.30 263 664 4.00 / 62.08 2 9
Average= 3.65
(KJ/cycle)

Cycle 15 GMT 28/ 2/2021 21:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 29 15.27 399 177 0.18 / 54.19 3 3
2 7 2002.84 31 15.07 2833 1323 1.50 / 55.51 2 5
3 13 1597.04 33 15.04 2337 1160 2.66 / 56.67 2 10
4 13 626.08 33 15.23 1113 559 3.22 / 57.23 2 4
5 13 51.72 33 15.33 351 178 3.40 / 57.41 2 3
6 8 -0.12 165 15.30 263 664 4.06 / 58.07 2 5
Average= 3.63
(KJ/cycle)

Cycle 14 GMT 19/ 2/2021 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 15.28 395 175 0.18 / 50.13 3 3
2 7 2005.72 31 15.09 2828 1323 1.50 / 51.45 2 10
3 13 1598.84 33 15.05 2342 1163 2.66 / 52.62 2 12
4 13 636.48 33 15.23 1115 560 3.22 / 53.18 2 4
5 13 46.36 33 15.35 341 173 3.39 / 53.35 2 3
6 8 -0.12 165 15.31 262 662 4.06 / 54.01 2 8
Average= 3.60
(KJ/cycle)

Cycle 13 GMT 9/ 2/2021 2:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 29 15.29 412 183 0.18 / 46.07 3 3
2 7 2007.32 31 15.10 2837 1328 1.51 / 47.40 2 8
3 13 1589.72 33 15.06 2328 1157 2.67 / 48.56 2 7
4 13 622.36 33 15.24 1106 556 3.22 / 49.11 2 7
5 13 58.20 33 15.35 358 181 3.41 / 49.29 2 3
6 8 -0.12 165 15.32 262 662 4.07 / 49.96 2 6
Average= 3.57
(KJ/cycle)

Cycle 12 GMT 30/ 1/2021 5: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 29 15.28 418 185 0.19 / 41.99 3 3
2 7 2008.32 31 15.10 2854 1336 1.52 / 43.33 2 3
3 13 1594.52 33 15.07 2337 1162 2.68 / 44.49 2 5
4 13 616.08 33 15.23 1098 552 3.24 / 45.04 2 4
5 13 40.64 33 15.35 336 170 3.41 / 45.21 2 3
6 8 -0.08 165 15.32 267 675 4.08 / 45.89 2 6
Average= 3.53
(KJ/cycle)

Cycle 11 GMT 20/ 1/2021 7:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 29 15.29 409 181 0.18 / 37.90 3 3
2 7 2006.80 33 15.09 2836 1412 1.59 / 39.31 2 3
3 13 1590.32 32 15.07 2326 1122 2.72 / 40.43 2 6
4 13 626.60 32 15.24 1108 540 3.26 / 40.97 2 3
5 13 47.24 32 15.36 341 168 3.42 / 41.14 2 3
6 8 -0.24 165 15.32 264 667 4.09 / 41.81 2 5
Average= 3.48
(KJ/cycle)

Cycle 10 GMT 10/ 1/2021 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 29 15.29 411 182 0.18 / 33.86 3 3
2 7 2005.88 33 15.09 2847 1418 1.60 / 35.28 2 2
3 13 1470.80 32 15.10 2182 1054 2.65 / 36.33 2 2
4 13 647.16 32 15.23 1139 555 3.21 / 36.88 2 2
5 13 32.96 32 15.36 325 160 3.37 / 37.04 2 2
6 8 -0.20 165 15.33 266 673 4.04 / 37.72 2 3
Average= 3.43
(KJ/cycle)

Cycle 9 GMT 31/12/2020 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 29 15.30 420 186 0.19 / 29.77 3 3
2 7 2005.68 33 15.09 2833 1411 1.60 / 31.18 2 2
3 13 1595.44 32 15.08 2337 1128 2.72 / 32.31 2 2
4 13 622.96 32 15.25 1108 541 3.27 / 32.85 2 2
5 13 36.24 32 15.37 326 160 3.43 / 33.01 2 2
6 8 -0.04 165 15.33 264 668 4.09 / 33.68 2 6
Average= 3.37
(KJ/cycle)

Cycle 8 GMT 21/12/2020 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 29 15.28 419 186 0.19 / 25.83 3 3
2 7 2005.00 33 15.08 2843 1415 1.60 / 27.24 2 3
3 13 1461.08 32 15.10 2167 1047 2.65 / 28.29 2 2
4 13 513.68 32 15.27 966 472 3.12 / 28.76 2 2
5 13 27.48 32 15.35 313 154 3.27 / 28.91 2 2
6 8 -0.16 165 15.33 264 668 3.94 / 29.58 2 5
Average= 3.29
(KJ/cycle)

Cycle 7 GMT 11/12/2020 17:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 28 15.31 410 176 0.18 / 22.05 3 3
2 3 1022.28 1 15.39 1715 26 0.20 / 22.07 2 2
3 7 2004.64 33 15.11 2838 1415 1.62 / 23.49 2 2
4 13 1458.00 24 15.14 2171 789 2.41 / 24.28 2 2
5 13 727.80 24 15.25 1245 456 2.86 / 24.73 2 2
6 13 64.40 24 15.37 367 135 3.00 / 24.87 2 2
7 13 15.96 24 15.37 293 108 3.11 / 24.98 2 3
8 8 -0.08 165 15.33 263 665 3.77 / 25.64 2 9
Average= 3.21
(KJ/cycle)

Cycle 6 GMT 1/12/2020 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 15.30 386 159 0.16 / 18.25 3 3
2 3 1048.60 1 15.37 1738 27 0.19 / 18.28 2 2
3 7 2005.24 38 15.06 2844 1628 1.81 / 19.91 2 2
4 13 1419.36 18 15.16 2132 582 2.40 / 20.49 2 2
5 13 844.04 18 15.23 1403 385 2.78 / 20.87 2 2
6 13 250.12 18 15.34 616 170 2.95 / 21.04 2 2
7 13 29.32 18 15.39 319 88 3.04 / 21.13 2 3
8 13 23.48 18 15.37 306 85 3.12 / 21.21 2 2
9 8 0.08 165 15.34 259 656 3.78 / 21.87 2 3
Average= 3.12
(KJ/cycle)

Cycle 5 GMT 21/11/2020 21: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 29 15.32 389 173 0.17 / 14.59 3 3
2 3 959.60 -1 15.65 1 0 0.00 / 14.59 3 3
3 7 2004.16 38 15.07 2833 1622 1.80 / 16.22 2 2
4 13 1306.72 18 15.17 1989 543 2.34 / 16.76 2 2
5 13 756.40 18 15.25 1291 354 2.69 / 17.11 2 2
6 13 179.16 18 15.35 521 144 2.84 / 17.26 2 2
7 13 38.92 18 15.38 332 92 2.93 / 17.35 2 2
8 13 25.16 18 15.37 307 85 3.01 / 17.43 2 2
9 8 0.04 165 15.32 260 657 3.67 / 18.09 2 5
Average= 3.02
(KJ/cycle)

Cycle 4 GMT 11/11/2020 23: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 27 15.30 414 171 0.17 / 11.39 3 3
2 7 1520.72 38 15.19 2238 1292 1.46 / 12.68 2 2
3 13 1390.80 18 15.19 2075 567 2.03 / 13.25 2 2
4 13 644.44 18 15.28 1136 312 2.34 / 13.56 2 2
5 13 100.72 18 15.39 419 116 2.46 / 13.68 2 2
6 13 28.12 18 15.40 315 87 2.55 / 13.76 2 2
7 8 0.20 165 15.35 259 656 3.20 / 14.42 2 4
Average= 2.88
(KJ/cycle)

Cycle 3 GMT 10/11/2020 22:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 26 15.30 401 160 0.16 / 8.21 3 3
2 3 1047.64 1 15.36 1751 27 0.19 / 8.24 2 2
3 7 1527.24 38 15.18 2242 1293 1.48 / 9.53 2 2
4 13 1266.96 18 15.21 1934 529 2.01 / 10.06 2 2
5 13 566.16 18 15.30 1037 286 2.29 / 10.34 2 2
6 13 134.84 18 15.38 461 128 2.42 / 10.47 2 2
7 13 31.96 18 15.38 320 89 2.51 / 10.56 2 2
8 8 0.12 165 15.35 260 659 3.17 / 11.22 2 6
Average= 2.80
(KJ/cycle)

Cycle 2 GMT 9/11/2020 22:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 30 15.33 467 215 0.21 / 4.61 3 3
2 3 902.72 -2 15.67 1 0 0.00 / 4.61 3 3
3 3 961.64 -1 15.66 0 0 0.00 / 4.61 3 3
4 7 1508.16 74 15.11 2210 2471 2.69 / 7.08 2 2
5 13 130.92 18 15.39 464 129 2.81 / 7.21 2 2
6 13 33.08 18 15.39 328 91 2.91 / 7.30 2 2
7 13 12.16 18 15.39 294 81 2.99 / 7.38 2 3
8 8 0.12 165 15.35 265 671 3.66 / 8.05 2 6
Average= 2.68
(KJ/cycle)

Cycle 1 GMT 8/11/2020 22:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 27 15.50 421 176 0.18 / 1.75 3 3
2 3 1018.88 1 15.41 1725 27 0.20 / 1.78 2 2
3 7 1003.68 74 15.24 1577 1778 1.98 / 3.56 2 2
4 13 25.92 18 15.43 323 90 2.07 / 3.65 2 2
5 8 -0.08 165 15.38 294 746 2.82 / 4.39 2 4
Average= 2.20
(KJ/cycle)

Cycle 0 GMT 8/11/2020 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 87.12 26 15.62 357 145 0.14 / 0.14 3 3
2 7 101.08 74 15.59 363 419 0.56 / 0.56 3 3
3 13 13.00 18 15.60 249 70 0.63 / 0.63 3 3
4 8 -0.04 240 15.55 252 940 1.57 / 1.57 3 17
Average= 1.57
(KJ/cycle)