SIO Argo Site:
Pump Diagnostics Page   



Serial= 8858 WMO= 5906140

Return

←PreviousNext→

Cycle 165 GMT 9/12/2024 20:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 14 15.05 444 94 0.09 / 426.60 2 3
2 7 1430.60 38 14.86 2281 1288 1.38 / 427.89 2 5
3 13 664.76 22 14.99 1249 412 1.79 / 428.30 2 5
4 8 0.28 165 15.09 278 692 2.49 / 428.99 2 3
Average= 2.58
(KJ/cycle)

Cycle 164 GMT 30/11/2024 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 13 15.06 440 86 0.09 / 424.05 2 3
2 3 1023.08 1 15.03 1797 27 0.11 / 424.08 2 3
3 7 1430.76 39 14.87 2286 1326 1.44 / 425.41 2 3
4 13 675.76 22 14.99 1263 417 1.86 / 425.82 2 5
5 8 0.04 165 15.09 275 685 2.54 / 426.51 2 3
Average= 2.58
(KJ/cycle)

Cycle 163 GMT 20/11/2024 11:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 13 15.05 446 87 0.09 / 421.55 2 3
2 3 1028.16 1 15.01 1802 27 0.11 / 421.58 2 4
3 7 1429.40 38 14.86 2283 1289 1.40 / 422.87 2 3
4 13 674.52 22 14.99 1263 417 1.82 / 423.29 2 4
5 8 0.04 165 15.09 273 680 2.50 / 423.97 2 3
Average= 2.59
(KJ/cycle)

Cycle 162 GMT 10/11/2024 19: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 12 15.06 447 81 0.08 / 419.03 2 3
2 7 1428.24 39 14.86 2284 1324 1.40 / 420.36 2 4
3 13 676.88 22 14.98 1269 418 1.82 / 420.78 2 3
4 8 0.24 165 15.09 277 690 2.51 / 421.47 2 3
Average= 2.59
(KJ/cycle)

Cycle 161 GMT 1/11/2024 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 12 15.05 448 81 0.08 / 416.46 2 3
2 7 1428.72 39 14.86 2288 1326 1.41 / 417.79 2 5
3 13 789.92 22 14.96 1437 473 1.88 / 418.26 2 5
4 8 0.12 165 15.10 278 693 2.57 / 418.95 2 3
Average= 2.59
(KJ/cycle)

Cycle 160 GMT 22/10/2024 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 12 15.06 451 82 0.08 / 413.98 2 3
2 7 1432.20 38 14.85 2292 1293 1.37 / 415.27 2 4
3 13 674.80 22 14.98 1274 420 1.79 / 415.69 2 3
4 8 0.16 165 15.09 278 692 2.49 / 416.38 2 5
Average= 2.59
(KJ/cycle)

Cycle 159 GMT 12/10/2024 17: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 12 15.05 432 78 0.08 / 411.50 2 3
2 7 1431.60 38 14.86 2294 1295 1.37 / 412.79 2 4
3 13 674.16 22 14.98 1272 419 1.79 / 413.21 2 4
4 8 0.08 165 15.10 274 683 2.48 / 413.89 2 5
Average= 2.59
(KJ/cycle)

Cycle 158 GMT 3/10/2024 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 12 15.06 451 82 0.08 / 408.91 2 3
2 7 1427.64 38 14.85 2293 1294 1.38 / 410.21 2 4
3 13 643.92 22 14.99 1233 407 1.78 / 410.61 2 4
4 13 35.40 22 15.12 338 112 1.89 / 410.73 2 3
5 8 -0.04 165 15.09 278 692 2.59 / 411.42 2 3
Average= 2.59
(KJ/cycle)

Cycle 157 GMT 23/ 9/2024 7:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 12 15.06 450 81 0.08 / 406.43 2 3
2 7 1427.96 38 14.87 2288 1293 1.37 / 407.73 2 3
3 13 655.60 22 14.99 1251 413 1.79 / 408.14 2 4
4 8 0.00 165 15.10 278 693 2.48 / 408.83 2 5
Average= 2.59
(KJ/cycle)

Cycle 156 GMT 13/ 9/2024 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 12 15.05 434 78 0.08 / 403.89 2 3
2 10 1001.48 2 14.98 1795 54 0.13 / 403.94 2 3
3 3 951.52 -1 15.30 0 0 0.05 / 403.94 2 3
4 3 972.48 -1 15.34 0 0 0.05 / 403.94 2 3
5 7 1431.16 38 14.86 2291 1294 1.43 / 405.24 2 3
6 13 662.84 22 14.98 1269 418 1.84 / 405.66 2 4
7 8 0.12 165 15.09 280 697 2.54 / 406.35 2 3
Average= 2.59
(KJ/cycle)

Cycle 155 GMT 3/ 9/2024 22: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 12 15.06 439 79 0.08 / 401.29 2 3
2 7 1432.12 38 14.86 2301 1299 1.38 / 402.59 2 4
3 13 668.72 22 14.96 1267 417 1.80 / 403.01 2 5
4 13 40.60 22 15.11 347 115 1.91 / 403.12 2 4
5 8 0.00 165 15.08 277 689 2.60 / 403.81 2 4
Average= 2.59
(KJ/cycle)

Cycle 154 GMT 25/ 8/2024 5:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 12 15.06 439 79 0.08 / 398.83 2 3
2 7 1430.16 38 14.85 2296 1296 1.37 / 400.12 2 3
3 13 654.28 22 14.96 1248 411 1.79 / 400.53 2 4
4 8 0.24 165 15.08 273 679 2.46 / 401.21 2 3
Average= 2.59
(KJ/cycle)

Cycle 153 GMT 15/ 8/2024 12:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 12 15.05 437 79 0.08 / 396.40 2 3
2 7 1429.84 38 14.85 2298 1297 1.38 / 397.70 2 4
3 13 524.92 22 15.01 1070 353 1.73 / 398.05 2 3
4 8 0.00 165 15.09 279 695 2.42 / 398.75 2 4
Average= 2.59
(KJ/cycle)

Cycle 152 GMT 5/ 8/2024 19:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 12 15.07 443 80 0.08 / 393.76 2 3
2 7 1429.08 39 14.85 2298 1331 1.41 / 395.09 2 4
3 13 651.76 22 14.98 1248 411 1.82 / 395.51 2 4
4 8 0.00 165 15.09 278 692 2.51 / 396.20 2 18
5 14 0.00 30 15.06 278 126 2.64 / 396.32 2 7
Average= 2.59
(KJ/cycle)

Cycle 151 GMT 27/ 7/2024 2:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 12 15.06 451 82 0.08 / 391.29 2 3
2 7 1428.96 38 14.86 2289 1293 1.37 / 392.59 2 4
3 13 668.40 22 14.98 1267 418 1.79 / 393.00 2 5
4 8 0.20 165 15.10 273 680 2.47 / 393.68 2 3
Average= 2.59
(KJ/cycle)

Cycle 150 GMT 17/ 7/2024 9:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 12 15.05 458 83 0.08 / 388.71 2 3
2 7 1427.48 38 14.86 2292 1294 1.38 / 390.01 2 3
3 13 651.64 22 14.98 1249 412 1.79 / 390.42 2 3
4 13 15.32 22 15.13 306 102 1.89 / 390.52 2 3
5 8 0.00 165 15.08 277 689 2.58 / 391.21 2 4
Average= 2.59
(KJ/cycle)

Cycle 149 GMT 7/ 7/2024 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 12 15.06 456 82 0.08 / 386.24 2 3
2 7 1431.12 38 14.85 2299 1297 1.38 / 387.53 2 4
3 13 651.72 22 14.98 1243 410 1.79 / 387.94 2 3
4 8 -0.12 165 15.09 277 690 2.48 / 388.63 2 3
Average= 2.59
(KJ/cycle)

Cycle 148 GMT 28/ 6/2024 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 12 15.06 450 81 0.08 / 383.64 2 3
2 7 1430.04 38 14.85 2296 1296 1.38 / 384.94 2 5
3 13 641.80 22 14.98 1231 406 1.78 / 385.34 2 4
4 13 58.08 22 15.11 373 124 1.91 / 385.47 2 3
5 8 -0.04 165 15.08 276 687 2.59 / 386.15 2 4
Average= 2.59
(KJ/cycle)

Cycle 147 GMT 18/ 6/2024 7:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 12 15.07 444 80 0.08 / 381.04 3 3
2 7 1434.60 38 14.87 2295 1297 1.38 / 382.34 2 3
3 13 649.56 22 15.00 1237 408 1.79 / 382.75 2 5
4 13 31.68 22 15.13 336 112 1.90 / 382.86 2 3
5 8 0.24 165 15.10 280 698 2.59 / 383.56 2 2
Average= 2.59
(KJ/cycle)

Cycle 146 GMT 8/ 6/2024 14:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 13 15.06 434 85 0.08 / 378.34 2 3
2 7 1430.52 38 14.86 2289 1293 1.38 / 379.63 2 4
3 13 665.32 22 14.98 1258 415 1.79 / 380.05 2 3
4 13 42.48 22 15.12 347 115 1.91 / 380.16 2 2
5 8 0.00 165 15.09 273 680 2.59 / 380.84 2 4
6 14 0.00 30 15.06 273 123 2.71 / 380.96 2 5
Average= 2.59
(KJ/cycle)

Cycle 145 GMT 29/ 5/2024 21:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 12 15.06 447 81 0.08 / 375.75 3 3
2 7 1427.08 38 14.86 2284 1290 1.37 / 377.04 2 3
3 13 640.20 22 14.99 1222 403 1.77 / 377.44 2 4
4 13 71.04 22 15.11 397 132 1.91 / 377.57 2 4
5 8 -0.04 165 15.08 273 679 2.58 / 378.25 2 3
Average= 2.59
(KJ/cycle)

Cycle 144 GMT 20/ 5/2024 4:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 12 15.06 431 78 0.08 / 373.18 2 3
2 7 1430.00 38 14.87 2285 1291 1.37 / 374.47 2 3
3 13 649.28 22 15.00 1235 408 1.78 / 374.88 2 4
4 13 40.72 22 15.12 347 115 1.89 / 374.99 2 3
5 8 0.08 165 15.09 272 677 2.57 / 375.67 2 3
Average= 2.59
(KJ/cycle)

Cycle 143 GMT 10/ 5/2024 12:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 13 15.07 458 90 0.09 / 370.60 2 3
2 7 1429.00 38 14.85 2288 1291 1.38 / 371.89 2 4
3 13 662.48 22 14.99 1258 415 1.80 / 372.31 2 4
4 13 41.44 22 15.12 344 114 1.91 / 372.42 2 2
5 8 0.08 165 15.09 273 680 2.59 / 373.10 2 4
Average= 2.59
(KJ/cycle)

Cycle 142 GMT 30/ 4/2024 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 13 15.06 437 86 0.09 / 367.99 2 3
2 7 1427.80 38 14.87 2291 1295 1.38 / 369.29 2 4
3 13 668.00 22 15.00 1264 417 1.80 / 369.71 2 5
4 13 37.32 22 15.13 344 115 1.91 / 369.82 2 3
5 8 0.00 165 15.10 277 690 2.60 / 370.51 2 5
Average= 2.59
(KJ/cycle)

Cycle 141 GMT 21/ 4/2024 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 12 15.08 444 80 0.08 / 365.35 3 3
2 3 1017.08 1 15.05 1812 27 0.11 / 365.37 2 4
3 7 1437.48 38 14.87 2305 1302 1.41 / 366.68 2 5
4 13 668.80 22 15.00 1263 417 1.83 / 367.09 2 5
5 13 40.04 22 15.13 350 117 1.94 / 367.21 2 4
6 8 -0.04 165 15.10 280 698 2.64 / 367.91 2 3
Average= 2.59
(KJ/cycle)

Cycle 140 GMT 11/ 4/2024 9:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 12 15.06 439 79 0.08 / 362.76 2 3
2 7 1433.36 38 14.88 2295 1298 1.38 / 364.06 2 3
3 13 665.44 22 15.00 1261 416 1.79 / 364.48 2 3
4 13 42.76 22 15.13 346 115 1.91 / 364.59 2 3
5 8 0.00 165 15.10 271 675 2.58 / 365.27 2 3
Average= 2.59
(KJ/cycle)

Cycle 139 GMT 1/ 4/2024 16:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 12 15.06 441 80 0.08 / 360.13 3 3
2 7 1428.40 39 14.86 2293 1329 1.41 / 361.46 2 3
3 13 658.68 22 14.98 1255 414 1.82 / 361.88 2 3
4 13 43.84 22 15.12 351 117 1.94 / 361.99 2 3
5 8 -0.12 165 15.09 277 690 2.63 / 362.68 2 6
Average= 2.59
(KJ/cycle)

Cycle 138 GMT 23/ 3/2024 0: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 12 15.07 432 78 0.08 / 357.40 3 3
2 7 1427.96 38 14.87 2287 1292 1.37 / 358.70 2 4
3 13 672.32 22 14.99 1278 421 1.79 / 359.12 2 3
4 13 55.48 22 15.12 375 125 1.92 / 359.24 2 3
5 8 0.08 165 15.09 276 687 2.60 / 359.93 2 7
6 14 0.08 30 15.07 276 125 2.73 / 360.06 2 8
Average= 2.59
(KJ/cycle)

Cycle 137 GMT 13/ 3/2024 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 12 15.07 447 81 0.08 / 354.83 3 3
2 7 1429.08 38 14.86 2293 1295 1.38 / 356.13 2 5
3 13 661.84 22 14.99 1258 415 1.79 / 356.54 2 3
4 13 53.88 22 15.12 366 122 1.91 / 356.67 2 3
5 8 -0.08 165 15.10 265 660 2.57 / 357.33 2 4
Average= 2.59
(KJ/cycle)

Cycle 136 GMT 3/ 3/2024 13:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 12 15.07 436 79 0.08 / 352.24 2 3
2 7 1428.00 38 14.87 2291 1295 1.37 / 353.53 2 4
3 13 658.04 22 15.00 1256 414 1.79 / 353.95 2 3
4 13 49.80 22 15.12 361 120 1.91 / 354.07 2 3
5 8 0.00 165 15.10 275 685 2.59 / 354.75 2 3
Average= 2.59
(KJ/cycle)

Cycle 135 GMT 22/ 2/2024 21:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 12 15.08 424 77 0.08 / 349.53 2 3
2 7 1430.20 38 14.87 2297 1298 1.37 / 350.82 2 4
3 13 651.96 22 15.00 1250 412 1.79 / 351.24 2 4
4 13 47.80 22 15.12 356 118 1.91 / 351.36 2 3
5 8 0.04 165 15.10 274 683 2.59 / 352.04 2 8
6 14 0.04 30 15.08 272 123 2.71 / 352.16 3 3
Average= 2.59
(KJ/cycle)

Cycle 134 GMT 13/ 2/2024 4:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 13 15.09 442 87 0.09 / 346.92 3 3
2 7 1427.36 39 14.88 2287 1327 1.41 / 348.25 2 4
3 13 653.76 22 15.01 1247 412 1.83 / 348.66 2 3
4 13 44.88 22 15.13 346 115 1.94 / 348.78 2 4
5 8 -0.16 165 15.10 270 673 2.61 / 349.45 2 4
Average= 2.59
(KJ/cycle)

Cycle 133 GMT 3/ 2/2024 11:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 13 15.07 441 86 0.09 / 344.19 3 3
2 3 972.64 -1 15.37 0 0 0.00 / 344.19 3 3
3 3 1030.00 1 15.07 1855 28 0.11 / 344.22 2 3
4 7 1428.16 39 14.87 2290 1328 1.44 / 345.55 2 5
5 13 791.16 22 14.97 1441 475 1.92 / 346.03 2 5
6 13 60.32 22 15.14 376 125 2.04 / 346.15 2 4
7 8 0.08 165 15.11 275 686 2.73 / 346.84 2 4
Average= 2.59
(KJ/cycle)

Cycle 132 GMT 24/ 1/2024 16: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 13 15.06 424 83 0.08 / 341.54 2 3
2 7 1429.04 38 14.87 2292 1295 1.38 / 342.83 2 4
3 13 788.04 22 14.97 1431 471 1.85 / 343.31 2 4
4 13 55.72 22 15.13 368 122 1.97 / 343.43 2 4
5 8 0.00 165 15.10 273 680 2.65 / 344.11 2 3
Average= 2.59
(KJ/cycle)

Cycle 131 GMT 14/ 1/2024 20:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 13 15.07 438 86 0.09 / 338.95 3 3
2 7 1432.16 38 14.87 2298 1299 1.38 / 340.25 2 3
3 13 668.72 22 15.01 1263 417 1.80 / 340.67 2 3
4 13 44.44 22 15.14 345 115 1.92 / 340.79 2 3
5 8 -0.12 165 15.11 269 671 2.59 / 341.46 2 5
Average= 2.59
(KJ/cycle)

Cycle 130 GMT 5/ 1/2024 1: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 13 15.07 429 84 0.08 / 336.32 3 3
2 7 1430.12 39 14.86 2291 1328 1.41 / 337.65 2 3
3 13 674.72 22 15.00 1266 418 1.83 / 338.06 2 4
4 13 79.24 22 15.12 401 133 1.96 / 338.20 2 3
5 8 0.00 165 15.10 270 673 2.64 / 338.87 2 3
Average= 2.59
(KJ/cycle)

Cycle 129 GMT 26/12/2023 5:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 13 15.08 450 88 0.09 / 333.72 2 3
2 7 1430.76 38 14.88 2291 1295 1.38 / 335.02 2 4
3 13 673.84 22 15.01 1272 420 1.80 / 335.44 2 4
4 13 43.80 22 15.13 346 115 1.92 / 335.55 2 3
5 8 0.12 165 15.10 274 683 2.60 / 336.23 2 3
Average= 2.59
(KJ/cycle)

Cycle 128 GMT 16/12/2023 10:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 13 15.08 425 83 0.08 / 331.03 2 3
2 7 1427.04 39 14.88 2295 1332 1.42 / 332.36 2 3
3 13 792.96 22 14.99 1440 475 1.89 / 332.83 2 3
4 13 57.40 22 15.13 367 122 2.01 / 332.96 2 4
5 8 -0.12 165 15.10 271 675 2.69 / 333.63 2 8
Average= 2.59
(KJ/cycle)

Cycle 127 GMT 6/12/2023 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 13 15.08 424 83 0.08 / 328.45 2 3
2 7 1427.08 38 14.88 2298 1299 1.38 / 329.75 2 3
3 13 669.08 22 15.00 1258 415 1.80 / 330.16 2 3
4 13 41.72 22 15.14 340 113 1.91 / 330.28 2 3
5 8 0.48 165 15.11 268 668 2.58 / 330.94 2 7
Average= 2.59
(KJ/cycle)

Cycle 126 GMT 26/11/2023 19:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 13 15.07 437 86 0.09 / 325.84 2 3
2 7 1427.16 38 14.88 2293 1297 1.38 / 327.13 2 3
3 13 672.40 22 15.01 1269 419 1.80 / 327.55 2 4
4 13 75.76 22 15.13 399 133 1.93 / 327.68 2 3
5 8 -0.16 165 15.11 273 681 2.61 / 328.37 2 3
Average= 2.59
(KJ/cycle)

Cycle 125 GMT 17/11/2023 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 13 15.07 453 89 0.09 / 323.21 2 3
2 3 1018.64 1 15.08 1838 28 0.12 / 323.24 2 3
3 7 1432.52 38 14.89 2300 1301 1.42 / 324.54 2 3
4 13 679.96 22 15.00 1281 423 1.84 / 324.96 2 3
5 13 39.44 22 15.14 340 113 1.95 / 325.07 2 2
6 8 0.04 165 15.11 272 678 2.63 / 325.75 2 17
Average= 2.59
(KJ/cycle)

Cycle 124 GMT 7/11/2023 5: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 13 15.08 457 90 0.09 / 320.60 2 3
2 7 1428.76 38 14.88 2299 1300 1.39 / 321.90 2 4
3 13 680.12 22 15.01 1280 423 1.81 / 322.32 2 3
4 13 43.20 22 15.14 347 116 1.93 / 322.44 2 4
5 8 -0.08 165 15.11 274 683 2.61 / 323.12 2 3
Average= 2.58
(KJ/cycle)

Cycle 123 GMT 28/10/2023 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 13 15.08 452 89 0.09 / 317.98 3 3
2 7 1431.60 38 14.89 2301 1302 1.39 / 319.28 2 3
3 13 668.12 22 15.01 1272 420 1.81 / 319.70 2 5
4 13 39.64 22 15.14 348 116 1.93 / 319.82 2 3
5 8 0.08 165 15.11 277 691 2.62 / 320.51 2 3
Average= 2.58
(KJ/cycle)

Cycle 122 GMT 18/10/2023 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 13 15.08 430 84 0.08 / 315.36 2 3
2 7 1426.52 38 14.88 2301 1301 1.39 / 316.66 2 3
3 13 670.04 22 15.00 1274 420 1.81 / 317.08 2 3
4 13 40.72 22 15.14 344 115 1.92 / 317.20 2 3
5 8 0.00 165 15.11 279 696 2.62 / 317.89 2 3
Average= 2.58
(KJ/cycle)

Cycle 121 GMT 8/10/2023 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 13 15.09 434 85 0.09 / 312.75 2 3
2 7 1429.72 38 14.89 2306 1305 1.39 / 314.06 2 5
3 13 671.84 22 15.02 1276 422 1.81 / 314.48 2 3
4 13 37.24 22 15.15 336 112 1.92 / 314.59 2 3
5 8 0.04 165 15.12 274 684 2.61 / 315.27 2 4
Average= 2.58
(KJ/cycle)

Cycle 120 GMT 28/ 9/2023 23:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 13 15.09 433 85 0.08 / 310.09 2 3
2 7 1429.08 38 14.88 2295 1298 1.38 / 311.39 2 3
3 13 790.76 22 14.99 1440 475 1.86 / 311.87 2 4
4 13 56.20 22 15.14 365 122 1.98 / 311.99 2 2
5 8 0.00 165 15.12 273 681 2.66 / 312.67 2 3
Average= 2.58
(KJ/cycle)

Cycle 119 GMT 19/ 9/2023 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 13 15.09 454 89 0.09 / 307.42 2 3
2 7 1431.04 38 14.88 2301 1301 1.39 / 308.72 2 3
3 13 808.84 22 14.97 1464 482 1.87 / 309.20 2 5
4 13 66.12 22 15.14 384 128 2.00 / 309.33 2 3
5 8 0.28 165 15.11 273 681 2.68 / 310.01 2 4
Average= 2.58
(KJ/cycle)

Cycle 118 GMT 9/ 9/2023 8:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 13 15.10 446 88 0.09 / 304.79 2 3
2 7 1430.20 38 14.89 2299 1301 1.39 / 306.09 2 3
3 13 674.24 22 15.01 1270 419 1.81 / 306.51 2 4
4 13 79.68 22 15.14 405 135 1.94 / 306.64 2 3
5 8 0.00 165 15.12 275 686 2.63 / 307.33 2 3
Average= 2.58
(KJ/cycle)

Cycle 117 GMT 30/ 8/2023 13:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 14 15.09 455 96 0.10 / 302.23 2 3
2 7 1431.32 38 14.89 2296 1299 1.40 / 303.52 2 5
3 13 795.64 22 14.98 1446 477 1.87 / 304.00 2 4
4 8 0.00 165 15.14 279 697 2.57 / 304.70 2 4
Average= 2.58
(KJ/cycle)

Cycle 116 GMT 20/ 8/2023 17:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 14 15.09 439 93 0.09 / 299.71 2 3
2 7 1432.60 38 14.88 2293 1297 1.39 / 301.01 2 5
3 13 668.60 22 15.01 1259 416 1.81 / 301.42 2 3
4 8 0.12 165 15.12 284 709 2.51 / 302.13 2 6
Average= 2.58
(KJ/cycle)

Cycle 115 GMT 10/ 8/2023 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 14 15.10 450 95 0.10 / 297.12 2 3
2 7 1427.36 38 14.89 2284 1292 1.39 / 298.41 2 5
3 13 667.36 22 15.02 1252 414 1.80 / 298.82 2 4
4 13 32.36 22 15.16 330 110 1.91 / 298.93 2 2
5 8 0.04 165 15.12 274 684 2.59 / 299.62 2 2
Average= 2.58
(KJ/cycle)

Cycle 114 GMT 1/ 8/2023 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 14 15.10 445 94 0.09 / 294.62 2 3
2 7 1432.56 38 14.89 2294 1298 1.39 / 295.92 2 3
3 13 684.72 22 15.01 1277 422 1.81 / 296.34 2 3
4 8 -0.08 165 15.13 274 684 2.50 / 297.02 2 9
Average= 2.58
(KJ/cycle)

Cycle 113 GMT 22/ 7/2023 7:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 14 15.11 443 94 0.09 / 292.13 2 3
2 7 1429.08 38 14.90 2278 1290 1.38 / 293.42 2 4
3 13 673.68 22 15.03 1261 417 1.80 / 293.84 2 4
4 8 0.24 165 15.14 274 684 2.48 / 294.52 2 5
Average= 2.58
(KJ/cycle)

Cycle 112 GMT 12/ 7/2023 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 14 15.12 445 94 0.09 / 289.54 2 3
2 7 1430.24 38 14.90 2286 1294 1.39 / 290.84 2 3
3 13 676.84 22 15.03 1260 417 1.81 / 291.26 2 4
4 13 37.68 22 15.16 332 111 1.92 / 291.37 2 5
5 8 0.04 165 15.13 269 672 2.59 / 292.04 2 7
Average= 2.58
(KJ/cycle)

Cycle 111 GMT 2/ 7/2023 17: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 13 15.10 440 86 0.09 / 286.88 2 3
2 7 1428.24 38 14.90 2285 1294 1.38 / 288.18 2 3
3 13 792.36 22 15.01 1433 473 1.85 / 288.65 2 4
4 8 0.00 165 15.15 271 677 2.53 / 289.33 2 7
5 14 0.00 30 15.13 272 123 2.65 / 289.45 2 7
Average= 2.58
(KJ/cycle)

Cycle 110 GMT 22/ 6/2023 21:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 13 15.12 451 89 0.09 / 284.27 2 3
2 7 1431.12 38 14.89 2285 1293 1.38 / 285.56 2 3
3 13 670.28 22 15.02 1253 414 1.80 / 285.98 2 3
4 13 96.92 22 15.14 429 143 1.94 / 286.12 2 3
5 8 0.12 165 15.13 271 677 2.62 / 286.80 2 3
Average= 2.58
(KJ/cycle)

Cycle 109 GMT 13/ 6/2023 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 13 15.11 452 89 0.09 / 281.79 2 3
2 7 1427.20 38 14.90 2281 1292 1.38 / 283.09 2 4
3 13 675.68 22 15.03 1259 416 1.80 / 283.50 2 4
4 8 0.28 165 15.14 272 679 2.48 / 284.18 2 3
Average= 2.58
(KJ/cycle)

Cycle 108 GMT 3/ 6/2023 6:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 13 15.11 445 87 0.09 / 279.10 2 3
2 7 1427.64 39 14.91 2283 1328 1.41 / 280.43 2 4
3 13 789.20 22 15.02 1430 473 1.89 / 280.90 2 4
4 13 52.92 22 15.17 363 121 2.01 / 281.02 2 3
5 8 -0.04 165 15.14 274 684 2.69 / 281.71 2 7
Average= 2.58
(KJ/cycle)

Cycle 107 GMT 24/ 5/2023 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 13 15.13 445 88 0.09 / 276.51 2 3
2 7 1428.72 38 14.91 2285 1295 1.38 / 277.80 2 3
3 13 666.48 22 15.03 1247 412 1.79 / 278.21 2 4
4 13 37.88 22 15.16 333 111 1.91 / 278.33 2 2
5 8 0.12 165 15.14 275 687 2.59 / 279.01 2 4
Average= 2.58
(KJ/cycle)

Cycle 106 GMT 14/ 5/2023 16: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 13 15.12 435 86 0.09 / 273.93 3 3
2 7 1429.68 39 14.91 2282 1327 1.41 / 275.26 2 3
3 13 797.88 22 15.02 1438 475 1.89 / 275.73 2 3
4 8 0.04 165 15.16 275 688 2.58 / 276.42 2 3
Average= 2.58
(KJ/cycle)

Cycle 105 GMT 4/ 5/2023 20:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 13 15.12 435 86 0.09 / 271.31 3 3
2 7 1435.56 38 14.91 2293 1299 1.38 / 272.61 2 3
3 13 670.44 22 15.05 1255 416 1.80 / 273.03 2 4
4 13 79.80 22 15.16 405 135 1.94 / 273.16 2 4
5 8 0.00 165 15.15 273 682 2.62 / 273.84 2 3
Average= 2.58
(KJ/cycle)

Cycle 104 GMT 25/ 4/2023 1:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 13 15.13 446 88 0.09 / 268.72 3 3
2 7 1427.60 38 14.91 2279 1291 1.38 / 270.01 2 5
3 13 675.24 22 15.04 1265 419 1.80 / 270.43 2 3
4 13 43.20 22 15.18 348 116 1.91 / 270.55 2 3
5 8 0.00 165 15.15 272 680 2.59 / 271.23 2 8
Average= 2.58
(KJ/cycle)

Cycle 103 GMT 15/ 4/2023 6: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 13 15.12 430 85 0.08 / 266.12 2 3
2 7 1429.32 38 14.92 2284 1295 1.38 / 267.42 2 3
3 13 668.76 22 15.04 1255 415 1.79 / 267.83 2 4
4 13 39.84 22 15.18 341 114 1.91 / 267.95 2 4
5 8 0.00 165 15.15 274 685 2.59 / 268.63 2 3
Average= 2.58
(KJ/cycle)

Cycle 102 GMT 5/ 4/2023 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 13 15.12 440 86 0.09 / 263.54 3 3
2 7 1427.64 38 14.92 2279 1292 1.38 / 264.84 2 4
3 13 661.80 22 15.06 1237 410 1.79 / 265.25 2 3
4 13 46.96 22 15.18 348 116 1.90 / 265.36 2 3
5 8 -0.04 165 15.16 271 678 2.58 / 266.04 2 8
Average= 2.58
(KJ/cycle)

Cycle 101 GMT 26/ 3/2023 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 13 15.13 429 84 0.08 / 260.94 2 3
2 7 1427.44 38 14.91 2290 1297 1.38 / 262.24 2 3
3 13 674.24 22 15.04 1259 417 1.80 / 262.65 2 4
4 13 41.20 22 15.18 344 115 1.91 / 262.77 2 3
5 8 0.00 165 15.15 276 690 2.60 / 263.46 2 7
Average= 2.58
(KJ/cycle)

Cycle 100 GMT 16/ 3/2023 19:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 13 15.12 449 88 0.09 / 258.35 3 3
2 7 1427.80 38 14.92 2284 1295 1.38 / 259.65 2 6
3 13 671.44 22 15.04 1253 415 1.80 / 260.06 2 4
4 13 41.52 22 15.18 343 115 1.91 / 260.18 2 2
5 8 0.12 165 15.15 270 675 2.59 / 260.85 2 2
Average= 2.58
(KJ/cycle)

Cycle 99 GMT 7/ 3/2023 0:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 14 15.13 441 93 0.09 / 255.67 2 3
2 7 1430.04 38 14.93 2293 1301 1.39 / 256.97 2 3
3 13 803.04 22 15.02 1451 479 1.87 / 257.45 2 4
4 13 57.12 22 15.18 375 125 2.00 / 257.57 2 5
5 8 0.04 165 15.15 277 692 2.69 / 258.27 2 11
Average= 2.58
(KJ/cycle)

Cycle 98 GMT 25/ 2/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 14 15.12 444 94 0.09 / 253.06 2 3
2 7 1429.20 38 14.92 2294 1301 1.39 / 254.36 2 4
3 13 660.68 22 15.05 1243 412 1.81 / 254.78 2 4
4 13 16.76 22 15.19 310 104 1.91 / 254.88 2 3
5 8 0.12 165 15.16 278 695 2.61 / 255.57 2 8
Average= 2.58
(KJ/cycle)

Cycle 97 GMT 15/ 2/2023 9:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 14 15.12 446 94 0.09 / 250.44 2 4
2 7 1432.48 38 14.91 2296 1301 1.40 / 251.74 2 4
3 13 676.40 22 15.04 1267 419 1.81 / 252.16 2 3
4 13 28.76 22 15.18 329 110 1.92 / 252.27 2 4
5 8 -0.08 165 15.15 279 697 2.62 / 252.97 2 3
Average= 2.58
(KJ/cycle)

Cycle 96 GMT 5/ 2/2023 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 14 15.14 451 96 0.10 / 247.82 2 3
2 7 1426.88 38 14.92 2288 1297 1.39 / 249.11 2 3
3 13 663.32 22 15.06 1246 413 1.81 / 249.53 2 4
4 8 0.08 165 15.17 277 693 2.50 / 250.22 2 7
5 14 0.08 30 15.15 279 127 2.63 / 250.35 2 7
Average= 2.58
(KJ/cycle)

Cycle 95 GMT 26/ 1/2023 19:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 14 15.13 446 94 0.09 / 245.21 2 3
2 7 1432.36 38 14.92 2289 1298 1.39 / 246.51 2 5
3 13 675.84 22 15.05 1263 418 1.81 / 246.93 2 4
4 13 16.48 22 15.19 306 102 1.91 / 247.03 2 3
5 8 -0.08 165 15.16 277 693 2.61 / 247.72 2 3
Average= 2.58
(KJ/cycle)

Cycle 94 GMT 16/ 1/2023 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 14 15.13 445 94 0.09 / 242.60 2 3
2 7 1431.24 38 14.93 2287 1298 1.39 / 243.90 2 3
3 13 666.32 22 15.06 1251 414 1.81 / 244.31 2 5
4 13 28.60 22 15.20 325 109 1.91 / 244.42 2 2
5 8 0.20 165 15.16 278 695 2.61 / 245.12 2 3
Average= 2.58
(KJ/cycle)

Cycle 93 GMT 7/ 1/2023 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 14 15.14 448 95 0.09 / 240.10 2 3
2 7 1429.88 38 14.93 2290 1299 1.39 / 241.40 2 3
3 13 674.92 22 15.06 1261 418 1.81 / 241.81 2 3
4 8 0.04 165 15.17 277 693 2.51 / 242.51 2 3
Average= 2.58
(KJ/cycle)

Cycle 92 GMT 28/12/2022 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 14 15.15 445 94 0.09 / 237.59 2 3
2 7 1429.56 38 14.93 2287 1298 1.39 / 238.89 2 5
3 13 674.04 22 15.06 1260 417 1.81 / 239.30 2 4
4 8 0.20 165 15.17 279 698 2.51 / 240.00 2 4
Average= 2.58
(KJ/cycle)

Cycle 91 GMT 18/12/2022 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 14 15.14 441 93 0.09 / 235.09 2 3
2 7 1427.20 38 14.94 2286 1298 1.39 / 236.39 2 3
3 13 667.44 22 15.07 1249 414 1.81 / 236.80 2 4
4 8 0.08 165 15.18 276 691 2.50 / 237.49 2 5
Average= 2.58
(KJ/cycle)

Cycle 90 GMT 8/12/2022 18:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 14 15.14 453 96 0.10 / 232.50 2 3
2 7 1428.72 39 14.93 2284 1330 1.43 / 233.83 2 3
3 13 794.64 22 15.03 1429 473 1.90 / 234.31 2 5
4 8 -0.04 165 15.18 276 691 2.59 / 235.00 2 5
Average= 2.58
(KJ/cycle)

Cycle 89 GMT 28/11/2022 23:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 14 15.14 440 93 0.09 / 229.94 2 3
2 7 1427.56 38 14.92 2289 1298 1.39 / 231.24 2 3
3 13 794.44 22 15.03 1431 473 1.86 / 231.71 2 5
4 8 0.08 165 15.18 278 696 2.56 / 232.41 2 5
Average= 2.58
(KJ/cycle)

Cycle 88 GMT 19/11/2022 4:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 14 15.15 441 94 0.09 / 227.44 2 3
2 7 1433.84 38 14.92 2294 1301 1.39 / 228.74 2 4
3 13 664.16 22 15.07 1242 412 1.81 / 229.15 2 3
4 8 0.16 165 15.18 277 694 2.50 / 229.85 2 3
Average= 2.58
(KJ/cycle)

Cycle 87 GMT 9/11/2022 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 14 15.16 449 95 0.10 / 224.93 2 3
2 7 1430.04 38 14.94 2290 1300 1.40 / 226.23 2 6
3 13 690.68 22 15.06 1283 425 1.82 / 226.65 2 5
4 8 -0.20 165 15.19 277 694 2.51 / 227.35 2 3
Average= 2.58
(KJ/cycle)

Cycle 86 GMT 30/10/2022 13:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 14 15.16 459 97 0.10 / 222.41 2 3
2 7 1429.84 38 14.95 2289 1300 1.40 / 223.71 2 4
3 13 673.72 22 15.08 1262 419 1.82 / 224.13 2 5
4 8 0.24 165 15.19 279 699 2.52 / 224.83 2 3
Average= 2.58
(KJ/cycle)

Cycle 85 GMT 20/10/2022 18:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 14 15.15 452 96 0.10 / 219.89 2 3
2 7 1428.24 38 14.94 2290 1300 1.40 / 221.19 2 3
3 13 683.60 22 15.07 1274 422 1.82 / 221.61 2 3
4 8 0.00 165 15.19 281 704 2.52 / 222.32 2 3
Average= 2.59
(KJ/cycle)

Cycle 84 GMT 10/10/2022 23: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 14 15.17 451 96 0.10 / 217.38 2 3
2 7 1430.36 38 14.93 2286 1297 1.39 / 218.68 2 4
3 13 655.84 22 15.07 1237 410 1.80 / 219.09 2 4
4 8 0.00 165 15.19 282 707 2.51 / 219.79 2 5
Average= 2.59
(KJ/cycle)

Cycle 83 GMT 1/10/2022 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 14 15.17 463 98 0.10 / 214.75 2 3
2 7 1427.20 38 14.95 2281 1296 1.39 / 216.04 2 4
3 13 672.00 22 15.08 1261 418 1.81 / 216.46 2 4
4 8 0.12 165 15.20 278 697 2.51 / 217.16 2 2
5 14 0.12 30 15.18 280 128 2.64 / 217.28 2 3
Average= 2.59
(KJ/cycle)

Cycle 82 GMT 21/ 9/2022 8:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 14 15.18 449 95 0.10 / 212.21 2 3
2 7 1429.20 38 14.95 2292 1302 1.40 / 213.51 2 4
3 13 679.52 22 15.08 1280 425 1.82 / 213.94 2 3
4 8 0.24 165 15.20 282 707 2.53 / 214.65 2 4
Average= 2.59
(KJ/cycle)

Cycle 81 GMT 11/ 9/2022 12:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 14 15.18 455 97 0.10 / 209.69 2 3
2 7 1433.64 38 14.96 2300 1308 1.40 / 211.00 2 4
3 13 670.88 22 15.09 1262 419 1.82 / 211.42 2 4
4 8 -0.12 165 15.21 279 700 2.52 / 212.12 2 3
Average= 2.59
(KJ/cycle)

Cycle 80 GMT 1/ 9/2022 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 14 15.17 443 94 0.09 / 207.17 2 3
2 7 1427.04 38 14.96 2284 1298 1.39 / 208.47 2 4
3 13 670.72 22 15.09 1259 418 1.81 / 208.89 2 3
4 8 -0.04 165 15.22 280 703 2.51 / 209.59 2 3
Average= 2.59
(KJ/cycle)

Cycle 79 GMT 22/ 8/2022 22:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 14 15.18 458 97 0.10 / 204.65 2 3
2 7 1429.48 38 14.95 2293 1303 1.40 / 205.96 2 3
3 13 662.52 22 15.08 1251 415 1.82 / 206.37 2 3
4 8 0.40 165 15.21 282 708 2.52 / 207.08 2 3
Average= 2.59
(KJ/cycle)

Cycle 78 GMT 13/ 8/2022 3: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 14 15.19 462 98 0.10 / 202.15 2 3
2 7 1427.80 38 14.95 2285 1298 1.40 / 203.45 2 3
3 13 663.96 22 15.09 1248 414 1.81 / 203.86 2 3
4 8 -0.08 165 15.21 277 695 2.51 / 204.56 2 3
Average= 2.59
(KJ/cycle)

Cycle 77 GMT 3/ 8/2022 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 14 15.17 451 96 0.10 / 199.50 2 3
2 7 1426.96 38 14.96 2290 1302 1.40 / 200.80 2 3
3 13 676.84 22 15.09 1271 422 1.82 / 201.22 2 4
4 8 0.16 165 15.22 279 701 2.52 / 201.92 2 2
5 14 0.16 30 15.19 281 128 2.65 / 202.05 3 2
Average= 2.59
(KJ/cycle)

Cycle 76 GMT 24/ 7/2022 12:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 14 15.19 451 96 0.10 / 196.97 2 3
2 7 1429.56 38 14.96 2287 1300 1.40 / 198.27 2 5
3 13 680.72 22 15.10 1275 424 1.82 / 198.70 2 4
4 8 -0.08 165 15.22 281 706 2.53 / 199.40 2 3
Average= 2.59
(KJ/cycle)

Cycle 75 GMT 14/ 7/2022 17:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 13 15.19 449 89 0.09 / 194.46 2 3
2 7 1427.04 38 14.97 2282 1298 1.39 / 195.76 2 5
3 13 667.28 22 15.10 1249 415 1.80 / 196.18 2 3
4 8 0.04 165 15.22 280 703 2.50 / 196.88 2 3
Average= 2.59
(KJ/cycle)

Cycle 74 GMT 4/ 7/2022 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 13 15.21 462 91 0.09 / 191.94 2 3
2 7 1434.80 38 14.97 2298 1307 1.40 / 193.25 2 4
3 13 676.48 22 15.10 1270 422 1.82 / 193.67 2 3
4 8 0.16 165 15.23 279 701 2.52 / 194.37 2 2
Average= 2.59
(KJ/cycle)

Cycle 73 GMT 25/ 6/2022 2:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 13 15.21 437 86 0.09 / 189.43 2 3
2 7 1428.44 38 14.98 2292 1305 1.39 / 190.74 2 6
3 13 674.28 22 15.12 1257 418 1.81 / 191.16 2 5
4 8 0.16 165 15.24 276 694 2.50 / 191.85 2 2
Average= 2.59
(KJ/cycle)

Cycle 72 GMT 15/ 6/2022 7:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 13 15.20 458 91 0.09 / 186.94 2 3
2 7 1427.32 38 14.97 2297 1307 1.40 / 188.24 2 3
3 13 650.88 22 15.12 1230 409 1.81 / 188.65 2 3
4 8 -0.12 165 15.23 277 696 2.50 / 189.35 2 3
Average= 2.59
(KJ/cycle)

Cycle 71 GMT 5/ 6/2022 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 13 15.21 446 88 0.09 / 184.40 2 3
2 3 1022.88 1 15.17 1841 28 0.12 / 184.42 2 5
3 7 1430.56 38 14.97 2292 1304 1.42 / 185.73 2 4
4 13 670.12 22 15.11 1255 417 1.84 / 186.14 2 3
5 8 0.08 165 15.24 279 702 2.54 / 186.85 2 4
Average= 2.60
(KJ/cycle)

Cycle 70 GMT 26/ 5/2022 16:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 12 15.21 449 82 0.08 / 181.86 3 3
2 3 1020.12 1 15.17 1838 28 0.11 / 181.89 2 5
3 7 1431.36 38 14.97 2297 1307 1.42 / 183.19 2 3
4 13 677.16 22 15.11 1270 422 1.84 / 183.62 2 3
5 8 0.24 165 15.24 275 692 2.53 / 184.31 2 4
Average= 2.60
(KJ/cycle)

Cycle 69 GMT 16/ 5/2022 21:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 12 15.22 437 80 0.08 / 179.14 2 3
2 7 1427.80 38 14.97 2293 1304 1.38 / 180.44 2 3
3 13 664.48 22 15.11 1255 417 1.80 / 180.86 2 3
4 13 16.36 22 15.26 305 102 1.90 / 180.96 2 3
5 8 0.00 165 15.23 274 689 2.59 / 181.65 2 4
6 14 0.00 30 15.22 273 125 2.72 / 181.78 2 5
Average= 2.60
(KJ/cycle)

Cycle 68 GMT 7/ 5/2022 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 12 15.21 449 82 0.08 / 176.64 2 3
2 7 1431.12 38 14.96 2301 1308 1.39 / 177.95 2 4
3 13 661.16 22 15.10 1256 417 1.81 / 178.37 2 4
4 8 0.20 165 15.24 275 692 2.50 / 179.06 2 4
Average= 2.60
(KJ/cycle)

Cycle 67 GMT 27/ 4/2022 6:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 12 15.23 443 81 0.08 / 174.02 2 3
2 3 1018.80 1 15.19 1845 28 0.11 / 174.04 2 5
3 7 1428.60 38 14.96 2295 1305 1.41 / 175.35 2 5
4 13 649.80 22 15.12 1237 411 1.83 / 175.76 2 4
5 13 29.24 22 15.26 328 110 1.94 / 175.87 2 3
6 8 -0.12 165 15.24 275 692 2.63 / 176.56 2 7
Average= 2.60
(KJ/cycle)

Cycle 66 GMT 17/ 4/2022 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 12 15.23 432 79 0.08 / 171.41 2 3
2 7 1428.16 38 14.97 2302 1310 1.39 / 172.72 2 4
3 13 642.68 22 15.12 1236 411 1.80 / 173.13 2 4
4 13 15.28 22 15.28 305 103 1.90 / 173.23 2 2
5 8 0.08 165 15.25 280 705 2.61 / 173.93 2 3
Average= 2.60
(KJ/cycle)

Cycle 65 GMT 7/ 4/2022 15:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 12 15.21 429 78 0.08 / 168.76 2 3
2 7 1428.96 38 14.97 2302 1310 1.39 / 170.07 2 4
3 13 765.68 22 15.09 1411 468 1.86 / 170.54 2 3
4 13 25.32 22 15.28 314 106 1.96 / 170.64 2 3
5 8 0.04 165 15.25 273 687 2.65 / 171.33 2 3
Average= 2.60
(KJ/cycle)

Cycle 64 GMT 28/ 3/2022 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 12 15.22 438 80 0.08 / 166.16 3 3
2 7 1431.48 38 14.97 2308 1313 1.39 / 167.47 2 4
3 13 544.04 22 15.14 1104 368 1.76 / 167.84 2 3
4 13 95.76 22 15.25 439 147 1.91 / 167.99 2 4
5 8 -0.12 165 15.24 276 694 2.60 / 168.68 2 4
Average= 2.60
(KJ/cycle)

Cycle 63 GMT 19/ 3/2022 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 12 15.23 434 79 0.08 / 163.40 2 3
2 7 1428.80 38 14.97 2303 1310 1.39 / 164.71 2 5
3 13 650.28 22 15.12 1257 418 1.81 / 165.13 2 4
4 13 72.88 22 15.26 397 133 1.94 / 165.26 2 3
5 8 0.16 165 15.25 275 692 2.63 / 165.95 2 9
6 14 0.16 30 15.23 275 126 2.76 / 166.08 2 6
Average= 2.59
(KJ/cycle)

Cycle 62 GMT 9/ 3/2022 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 12 15.22 461 84 0.08 / 160.76 2 3
2 7 1426.24 38 14.98 2304 1312 1.40 / 162.08 2 4
3 13 650.40 22 15.11 1249 415 1.81 / 162.49 2 4
4 13 69.64 22 15.27 395 133 1.94 / 162.62 2 3
5 8 -0.04 165 15.25 276 694 2.64 / 163.32 2 6
Average= 2.59
(KJ/cycle)

Cycle 61 GMT 27/ 2/2022 8:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 12 15.23 440 80 0.08 / 158.13 2 3
2 7 1427.64 38 14.96 2301 1308 1.39 / 159.44 2 3
3 13 637.68 22 15.12 1230 409 1.80 / 159.85 2 3
4 13 74.56 22 15.26 400 134 1.93 / 159.98 2 3
5 8 0.16 165 15.25 277 697 2.63 / 160.68 2 3
Average= 2.59
(KJ/cycle)

Cycle 60 GMT 17/ 2/2022 13:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 12 15.22 446 81 0.08 / 155.50 2 3
2 7 1436.56 38 14.97 2312 1315 1.40 / 156.81 2 4
3 13 641.08 22 15.13 1232 410 1.81 / 157.22 2 4
4 13 62.56 22 15.27 386 130 1.94 / 157.35 2 4
5 8 0.08 165 15.25 278 700 2.64 / 158.05 2 5
Average= 2.59
(KJ/cycle)

Cycle 59 GMT 7/ 2/2022 17:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 12 15.25 427 78 0.08 / 152.85 3 3
2 7 1430.36 39 14.97 2292 1338 1.42 / 154.19 2 5
3 13 664.00 22 15.11 1260 419 1.84 / 154.61 2 5
4 13 35.80 22 15.27 336 113 1.95 / 154.72 2 3
5 8 0.00 165 15.25 275 692 2.64 / 155.42 2 4
Average= 2.59
(KJ/cycle)

Cycle 58 GMT 28/ 1/2022 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 12 15.25 428 78 0.08 / 150.26 3 3
2 7 1413.24 38 15.00 2269 1293 1.37 / 151.55 2 3
3 13 642.40 22 15.14 1224 408 1.78 / 151.96 2 4
4 13 67.04 22 15.28 384 129 1.91 / 152.09 2 3
5 8 0.24 165 15.27 272 685 2.59 / 152.78 2 3
Average= 2.59
(KJ/cycle)

Cycle 57 GMT 19/ 1/2022 2:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 12 15.24 442 81 0.08 / 147.64 2 3
2 3 1023.16 1 15.18 1841 28 0.11 / 147.67 2 4
3 7 1412.84 38 15.00 2267 1292 1.40 / 148.96 2 4
4 13 645.92 22 15.15 1230 410 1.81 / 149.37 2 3
5 13 64.36 22 15.29 382 128 1.94 / 149.50 2 3
6 8 -0.16 165 15.27 271 683 2.62 / 150.18 2 3
Average= 2.59
(KJ/cycle)

Cycle 56 GMT 9/ 1/2022 7:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 12 15.24 439 80 0.08 / 145.05 3 3
2 7 1412.16 38 14.99 2262 1288 1.37 / 146.34 2 4
3 13 647.00 22 15.14 1230 410 1.78 / 146.75 2 4
4 13 66.48 22 15.28 381 128 1.91 / 146.88 2 3
5 8 0.08 165 15.26 272 685 2.59 / 147.56 2 4
Average= 2.59
(KJ/cycle)

Cycle 55 GMT 30/12/2021 12: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 12 15.24 444 81 0.08 / 142.34 2 3
2 7 1413.32 38 14.99 2268 1292 1.37 / 143.63 2 3
3 13 647.20 22 15.14 1235 411 1.78 / 144.05 2 4
4 13 32.80 22 15.30 327 110 1.89 / 144.16 2 2
5 8 -0.12 165 15.27 273 688 2.58 / 144.84 2 5
6 14 -0.12 30 15.25 272 124 2.71 / 144.97 2 6
Average= 2.59
(KJ/cycle)

Cycle 54 GMT 20/12/2021 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 12 15.25 450 82 0.08 / 139.75 3 3
2 7 1414.96 38 15.00 2271 1294 1.38 / 141.04 2 4
3 13 625.64 22 15.15 1208 403 1.78 / 141.44 2 4
4 13 62.16 22 15.29 381 128 1.91 / 141.57 2 3
5 8 0.04 165 15.27 274 690 2.60 / 142.26 2 3
Average= 2.59
(KJ/cycle)

Cycle 53 GMT 10/12/2021 21:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 12 15.24 453 83 0.08 / 137.15 2 3
2 7 1415.36 39 15.00 2265 1325 1.41 / 138.47 2 4
3 13 619.04 22 15.15 1197 399 1.81 / 138.87 2 4
4 13 29.28 22 15.30 323 109 1.92 / 138.98 2 2
5 8 -0.04 165 15.28 272 686 2.60 / 139.66 2 3
Average= 2.59
(KJ/cycle)

Cycle 52 GMT 1/12/2021 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 11 15.25 442 74 0.07 / 134.56 2 3
2 3 1017.52 1 15.20 1843 28 0.10 / 134.59 2 5
3 7 1415.84 38 14.99 2268 1292 1.39 / 135.88 2 4
4 13 623.24 22 15.15 1202 401 1.79 / 136.28 2 3
5 13 28.08 22 15.30 318 107 1.90 / 136.38 2 3
6 8 0.12 165 15.27 269 678 2.58 / 137.06 2 3
Average= 2.59
(KJ/cycle)

Cycle 51 GMT 21/11/2021 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 11 15.25 438 73 0.07 / 131.99 2 3
2 7 1411.72 38 15.01 2252 1284 1.36 / 133.28 2 4
3 13 648.28 22 15.14 1233 411 1.77 / 133.69 2 5
4 13 32.20 22 15.30 327 110 1.88 / 133.80 2 3
5 8 -0.08 165 15.28 272 686 2.56 / 134.48 2 5
Average= 2.59
(KJ/cycle)

Cycle 50 GMT 11/11/2021 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 11 15.25 430 72 0.07 / 129.42 2 3
2 7 1413.12 38 15.00 2264 1290 1.36 / 130.71 2 3
3 13 639.96 22 15.15 1224 408 1.77 / 131.11 2 4
4 13 30.76 22 15.29 331 111 1.88 / 131.23 2 3
5 8 0.24 165 15.27 275 693 2.57 / 131.92 2 3
Average= 2.59
(KJ/cycle)

Cycle 49 GMT 1/11/2021 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 11 15.26 435 73 0.07 / 126.81 2 3
2 7 1415.48 39 15.00 2263 1324 1.40 / 128.13 2 5
3 13 646.52 22 15.14 1233 411 1.81 / 128.54 2 4
4 13 33.32 22 15.30 330 111 1.92 / 128.65 2 3
5 8 0.00 165 15.27 274 690 2.61 / 129.34 2 3
Average= 2.59
(KJ/cycle)

Cycle 48 GMT 22/10/2021 20: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 11 15.25 447 75 0.07 / 124.33 3 3
2 3 1016.12 1 15.21 1826 28 0.10 / 124.36 2 3
3 7 1418.80 38 15.01 2269 1294 1.40 / 125.65 2 5
4 13 630.28 22 15.15 1210 403 1.80 / 126.05 2 3
5 8 0.08 165 15.29 270 681 2.48 / 126.73 2 4
Average= 2.59
(KJ/cycle)

Cycle 47 GMT 13/10/2021 0:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 12 15.27 450 82 0.08 / 121.77 2 3
2 3 959.40 -1 15.51 0 0 0.00 / 121.77 2 3
3 7 1415.20 38 15.01 2259 1288 1.37 / 123.06 2 4
4 13 642.08 22 15.15 1222 407 1.78 / 123.46 2 3
5 13 33.64 22 15.30 330 111 1.89 / 123.58 2 3
6 8 0.20 165 15.27 269 678 2.57 / 124.25 2 4
Average= 2.59
(KJ/cycle)

Cycle 46 GMT 3/10/2021 5:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 12 15.26 445 81 0.08 / 119.34 2 3
2 7 1255.60 38 15.09 2043 1171 1.25 / 120.51 2 7
3 13 548.48 22 15.20 1091 365 1.62 / 120.88 2 3
4 13 44.80 22 15.32 352 119 1.74 / 120.99 2 3
5 8 0.04 165 15.30 274 692 2.43 / 121.69 2 4
Average= 2.59
(KJ/cycle)

Cycle 45 GMT 23/ 9/2021 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 13 15.27 453 90 0.09 / 116.78 3 3
2 7 1410.96 38 15.01 2260 1289 1.38 / 118.07 2 3
3 13 635.72 22 15.16 1214 405 1.78 / 118.47 2 4
4 13 12.56 22 15.32 300 101 1.88 / 118.57 2 3
5 8 -0.04 165 15.29 272 686 2.57 / 119.26 2 3
Average= 2.59
(KJ/cycle)

Cycle 44 GMT 13/ 9/2021 10:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 13 15.28 437 87 0.09 / 114.15 2 3
2 7 1416.04 39 15.03 2262 1326 1.41 / 115.48 2 3
3 13 648.08 22 15.18 1234 412 1.82 / 115.89 2 3
4 13 31.32 22 15.32 326 110 1.93 / 116.00 2 3
5 8 -0.08 165 15.30 272 687 2.62 / 116.69 2 3
Average= 2.59
(KJ/cycle)

Cycle 43 GMT 3/ 9/2021 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 13 15.28 430 85 0.09 / 111.67 3 3
2 7 1416.80 38 15.04 2264 1294 1.38 / 112.96 2 3
3 13 635.88 22 15.18 1207 403 1.78 / 113.36 2 3
4 8 0.20 165 15.31 278 702 2.48 / 114.07 2 7
Average= 2.59
(KJ/cycle)

Cycle 42 GMT 24/ 8/2021 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 12 15.30 443 81 0.08 / 109.07 2 3
2 7 1414.20 38 15.04 2264 1294 1.38 / 110.36 2 4
3 13 647.48 22 15.19 1222 408 1.78 / 110.77 2 3
4 13 72.52 22 15.33 391 132 1.92 / 110.90 2 2
5 8 0.00 165 15.32 269 680 2.60 / 111.58 2 4
Average= 2.59
(KJ/cycle)

Cycle 41 GMT 15/ 8/2021 0:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 12 15.29 447 82 0.08 / 106.53 2 3
2 7 1414.68 38 15.04 2263 1293 1.38 / 107.82 2 3
3 13 782.88 22 15.16 1420 474 1.85 / 108.29 2 5
4 8 0.12 165 15.33 274 693 2.54 / 108.99 2 3
Average= 2.59
(KJ/cycle)

Cycle 40 GMT 5/ 8/2021 5: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 12 15.30 454 83 0.08 / 103.94 3 3
2 7 1415.16 38 15.04 2268 1296 1.38 / 105.24 2 4
3 13 650.24 22 15.19 1230 411 1.79 / 105.65 2 3
4 13 14.68 22 15.34 303 102 1.89 / 105.75 2 2
5 8 0.16 165 15.31 274 692 2.59 / 106.44 2 4
Average= 2.60
(KJ/cycle)

Cycle 39 GMT 26/ 7/2021 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 12 15.29 450 83 0.08 / 101.35 3 3
2 7 1412.24 38 15.04 2264 1294 1.38 / 102.65 2 4
3 13 643.08 22 15.20 1226 410 1.79 / 103.06 2 3
4 13 35.24 22 15.35 336 113 1.90 / 103.17 2 3
5 8 0.04 165 15.32 272 688 2.59 / 103.86 2 8
Average= 2.60
(KJ/cycle)

Cycle 38 GMT 16/ 7/2021 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 12 15.29 446 82 0.08 / 98.80 3 3
2 7 1412.80 38 15.04 2266 1295 1.38 / 100.10 2 3
3 13 777.20 22 15.16 1416 472 1.85 / 100.57 2 4
4 8 0.16 165 15.32 277 700 2.55 / 101.27 2 4
Average= 2.60
(KJ/cycle)

Cycle 37 GMT 6/ 7/2021 18:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 12 15.29 441 81 0.08 / 96.20 3 3
2 7 1413.64 38 15.04 2261 1292 1.37 / 97.49 2 5
3 13 645.80 22 15.20 1229 411 1.78 / 97.91 2 4
4 13 28.88 22 15.34 329 111 1.90 / 98.02 2 3
5 8 0.08 165 15.31 279 705 2.60 / 98.72 2 3
Average= 2.60
(KJ/cycle)

Cycle 36 GMT 26/ 6/2021 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 12 15.30 447 82 0.08 / 93.57 2 3
2 7 1411.80 39 15.05 2262 1328 1.41 / 94.90 2 4
3 13 637.00 22 15.20 1216 407 1.82 / 95.31 2 3
4 13 29.60 22 15.35 331 112 1.93 / 95.42 2 3
5 8 -0.04 165 15.32 278 703 2.63 / 96.12 2 4
Average= 2.60
(KJ/cycle)

Cycle 35 GMT 17/ 6/2021 4: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 13 15.30 431 86 0.09 / 90.98 2 3
2 7 1412.32 38 15.05 2267 1296 1.38 / 92.27 2 5
3 13 636.96 22 15.20 1218 407 1.79 / 92.68 2 4
4 13 26.40 22 15.34 325 110 1.90 / 92.79 2 3
5 8 0.08 165 15.32 277 700 2.60 / 93.49 2 3
Average= 2.60
(KJ/cycle)

Cycle 34 GMT 7/ 6/2021 8:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 13 15.31 456 91 0.09 / 88.37 2 3
2 7 1416.36 38 15.05 2275 1301 1.39 / 89.67 2 4
3 13 638.44 22 15.21 1223 409 1.80 / 90.08 2 3
4 13 28.72 22 15.35 331 112 1.91 / 90.19 2 3
5 8 -0.04 165 15.33 276 698 2.61 / 90.89 2 3
Average= 2.60
(KJ/cycle)

Cycle 33 GMT 28/ 5/2021 13: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 13 15.31 445 89 0.09 / 85.77 2 3
2 7 1412.12 38 15.06 2265 1296 1.38 / 87.07 2 3
3 13 649.80 22 15.22 1232 413 1.80 / 87.48 2 4
4 13 14.24 22 15.36 304 103 1.90 / 87.58 2 3
5 8 0.04 165 15.33 275 696 2.60 / 88.28 2 3
Average= 2.60
(KJ/cycle)

Cycle 32 GMT 18/ 5/2021 17:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 13 15.30 434 86 0.09 / 83.16 3 3
2 7 1411.92 39 15.06 2258 1326 1.41 / 84.48 2 5
3 13 632.44 22 15.21 1213 406 1.82 / 84.89 2 3
4 13 13.32 22 15.37 301 102 1.92 / 84.99 2 2
5 8 0.04 165 15.33 274 693 2.61 / 85.68 2 6
Average= 2.60
(KJ/cycle)

Cycle 31 GMT 8/ 5/2021 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 12 15.32 439 81 0.08 / 80.56 3 3
2 7 1417.04 38 15.06 2260 1293 1.37 / 81.86 2 5
3 13 657.12 22 15.22 1238 415 1.79 / 82.27 2 3
4 13 31.84 22 15.35 329 111 1.90 / 82.38 2 3
5 8 0.12 165 15.33 272 688 2.59 / 83.07 2 3
Average= 2.60
(KJ/cycle)

Cycle 30 GMT 29/ 4/2021 2:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 12 15.31 448 82 0.08 / 77.91 3 3
2 3 1018.96 1 15.25 1825 28 0.11 / 77.94 2 5
3 7 1412.76 39 15.06 2261 1328 1.44 / 79.27 2 4
4 13 651.84 22 15.21 1235 413 1.85 / 79.68 2 3
5 13 31.68 22 15.36 329 111 1.96 / 79.80 2 3
6 8 -0.12 165 15.34 272 688 2.65 / 80.48 2 3
Average= 2.60
(KJ/cycle)

Cycle 29 GMT 19/ 4/2021 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 12 15.30 439 81 0.08 / 75.33 3 3
2 7 1414.32 38 15.06 2258 1292 1.37 / 76.62 2 3
3 13 654.36 22 15.22 1232 413 1.79 / 77.03 2 3
4 13 33.92 22 15.36 330 112 1.90 / 77.14 2 3
5 8 0.16 165 15.33 272 688 2.58 / 77.83 2 3
Average= 2.59
(KJ/cycle)

Cycle 28 GMT 9/ 4/2021 12:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 12 15.30 454 83 0.08 / 72.61 2 3
2 7 1411.60 38 15.06 2256 1291 1.37 / 73.90 2 4
3 13 644.44 22 15.21 1224 410 1.78 / 74.31 2 3
4 13 29.04 22 15.35 329 111 1.90 / 74.42 2 3
5 8 0.24 165 15.33 277 701 2.60 / 75.12 2 3
6 14 0.24 30 15.30 275 126 2.72 / 75.25 2 7
Average= 2.59
(KJ/cycle)

Cycle 27 GMT 30/ 3/2021 16:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 12 15.31 437 80 0.08 / 70.10 3 3
2 7 1416.44 38 15.06 2264 1296 1.38 / 71.40 2 4
3 13 657.88 22 15.21 1248 418 1.79 / 71.81 2 5
4 8 0.08 165 15.33 281 711 2.50 / 72.53 2 5
Average= 2.59
(KJ/cycle)

Cycle 26 GMT 20/ 3/2021 21:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 12 15.32 448 82 0.08 / 67.46 3 3
2 7 1412.32 39 15.06 2264 1330 1.41 / 68.79 2 4
3 13 646.52 22 15.23 1235 414 1.83 / 69.21 2 4
4 13 27.28 22 15.36 329 111 1.94 / 69.32 2 2
5 8 0.04 165 15.34 278 704 2.64 / 70.02 2 2
Average= 2.59
(KJ/cycle)

Cycle 25 GMT 11/ 3/2021 2: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 12 15.32 450 83 0.08 / 64.93 2 3
2 7 1412.68 39 15.07 2269 1334 1.42 / 66.26 2 4
3 13 635.08 22 15.23 1225 410 1.83 / 66.67 2 4
4 8 -0.12 165 15.35 280 709 2.54 / 67.38 2 3
Average= 2.59
(KJ/cycle)

Cycle 24 GMT 1/ 3/2021 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 12 15.31 445 82 0.08 / 62.30 2 3
2 7 1410.96 38 15.07 2264 1297 1.38 / 63.60 2 5
3 13 638.12 22 15.23 1228 411 1.79 / 64.01 2 3
4 8 0.00 165 15.35 279 707 2.50 / 64.72 2 4
5 14 0.00 30 15.33 282 130 2.63 / 64.84 2 3
Average= 2.59
(KJ/cycle)

Cycle 23 GMT 19/ 2/2021 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 12 15.32 445 82 0.08 / 59.79 2 3
2 7 1414.76 38 15.06 2268 1298 1.38 / 61.08 2 3
3 13 634.92 22 15.23 1224 410 1.79 / 61.49 2 4
4 8 -0.04 165 15.35 286 724 2.51 / 62.22 2 3
Average= 2.59
(KJ/cycle)

Cycle 22 GMT 9/ 2/2021 15:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 12 15.32 447 82 0.08 / 57.16 2 3
2 7 1412.68 38 15.07 2268 1299 1.38 / 58.46 2 3
3 13 629.88 22 15.23 1216 407 1.79 / 58.86 2 3
4 8 0.08 165 15.35 281 712 2.50 / 59.58 2 5
5 14 0.08 30 15.34 280 129 2.63 / 59.70 2 2
Average= 2.60
(KJ/cycle)

Cycle 21 GMT 30/ 1/2021 20:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 12 15.31 457 84 0.08 / 54.54 2 3
2 7 1415.12 38 15.07 2268 1299 1.38 / 55.84 2 5
3 13 634.40 22 15.23 1224 410 1.79 / 56.25 2 3
4 13 21.36 22 15.38 324 110 1.90 / 56.36 2 3
5 8 -0.04 165 15.35 283 717 2.62 / 57.08 2 5
Average= 2.59
(KJ/cycle)

Cycle 20 GMT 21/ 1/2021 0:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 12 15.32 450 83 0.08 / 51.89 2 3
2 7 1414.48 39 15.07 2274 1336 1.42 / 53.22 2 7
3 13 630.24 22 15.23 1218 408 1.83 / 53.63 2 3
4 13 22.04 22 15.37 324 110 1.94 / 53.74 2 2
5 8 -0.08 165 15.34 283 716 2.65 / 54.46 2 3
Average= 2.59
(KJ/cycle)

Cycle 19 GMT 11/ 1/2021 5:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 12 15.33 439 81 0.08 / 49.27 2 3
2 7 1411.28 38 15.08 2259 1294 1.38 / 50.57 2 8
3 13 637.60 22 15.24 1222 410 1.78 / 50.98 2 4
4 13 27.16 22 15.38 333 113 1.90 / 51.09 2 2
5 8 -0.04 165 15.35 282 714 2.61 / 51.80 2 3
Average= 2.59
(KJ/cycle)

Cycle 18 GMT 1/ 1/2021 9:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 12 15.33 443 81 0.08 / 46.64 2 3
2 7 1413.40 38 15.08 2266 1299 1.38 / 47.94 2 4
3 13 628.56 22 15.23 1214 407 1.79 / 48.35 2 5
4 8 0.12 165 15.36 281 712 2.50 / 49.06 2 4
5 14 0.12 30 15.34 282 130 2.63 / 49.19 2 4
Average= 2.59
(KJ/cycle)

Cycle 17 GMT 22/12/2020 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 11 15.32 443 75 0.07 / 44.12 2 3
2 3 1018.16 1 15.28 1840 28 0.10 / 44.14 2 5
3 7 1414.80 38 15.07 2270 1300 1.40 / 45.44 2 4
4 13 632.80 22 15.25 1218 409 1.81 / 45.85 2 4
5 8 0.16 165 15.36 280 710 2.52 / 46.56 2 5
Average= 2.59
(KJ/cycle)

Cycle 16 GMT 12/12/2020 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 11 15.32 443 75 0.07 / 41.61 2 3
2 7 1412.76 38 15.07 2268 1299 1.37 / 42.91 2 6
3 13 642.32 22 15.23 1227 411 1.78 / 43.32 2 4
4 8 0.08 165 15.35 283 717 2.50 / 44.04 2 4
Average= 2.59
(KJ/cycle)

Cycle 15 GMT 2/12/2020 23: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 11 15.34 441 74 0.07 / 39.18 2 3
2 7 1411.48 38 15.08 2262 1296 1.37 / 40.47 2 4
3 13 507.68 22 15.27 1038 349 1.72 / 40.82 2 3
4 8 0.16 165 15.36 283 717 2.44 / 41.54 2 3
Average= 2.60
(KJ/cycle)

Cycle 14 GMT 23/11/2020 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 11 15.33 438 74 0.07 / 36.68 2 3
2 7 1413.48 38 15.08 2268 1300 1.37 / 37.98 2 7
3 13 632.00 22 15.25 1220 409 1.78 / 38.39 2 4
4 8 0.12 165 15.36 282 715 2.50 / 39.10 2 2
Average= 2.61
(KJ/cycle)

Cycle 13 GMT 13/11/2020 8: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 11 15.33 460 78 0.08 / 34.18 2 3
2 7 1412.28 38 15.08 2270 1301 1.38 / 35.48 2 7
3 13 630.56 22 15.24 1222 410 1.79 / 35.89 2 5
4 8 -0.08 165 15.36 282 715 2.50 / 36.61 2 4
Average= 2.61
(KJ/cycle)

Cycle 12 GMT 3/11/2020 12:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 12 15.33 448 82 0.08 / 31.67 2 3
2 7 1416.28 38 15.07 2273 1302 1.38 / 32.97 2 3
3 13 631.36 22 15.23 1217 408 1.79 / 33.38 2 3
4 8 0.20 165 15.35 285 722 2.51 / 34.10 2 2
Average= 2.62
(KJ/cycle)

Cycle 11 GMT 24/10/2020 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 11 15.34 440 74 0.07 / 29.16 2 3
2 7 1412.08 38 15.08 2270 1301 1.38 / 30.46 2 3
3 13 630.44 22 15.24 1219 409 1.78 / 30.87 2 3
4 8 -0.08 165 15.36 285 722 2.51 / 31.59 2 4
Average= 2.63
(KJ/cycle)

Cycle 10 GMT 14/10/2020 20:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 11 15.35 448 76 0.08 / 26.66 2 3
2 7 1412.12 38 15.10 2267 1301 1.38 / 27.96 2 3
3 13 636.52 22 15.25 1220 409 1.79 / 28.37 2 3
4 8 0.00 165 15.37 282 715 2.50 / 29.08 2 4
Average= 2.64
(KJ/cycle)

Cycle 9 GMT 5/10/2020 1:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 11 15.36 452 76 0.08 / 24.21 2 3
2 7 1411.80 38 15.09 2267 1300 1.38 / 25.51 2 2
3 13 522.40 22 15.27 1061 356 1.73 / 25.87 2 3
4 8 0.20 165 15.36 283 717 2.45 / 26.58 2 3
Average= 2.66
(KJ/cycle)

Cycle 8 GMT 25/ 9/2020 5:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 11 15.34 449 76 0.08 / 21.67 3 3
2 7 1411.04 39 15.10 2270 1337 1.41 / 23.01 2 2
3 13 645.64 22 15.26 1237 415 1.83 / 23.42 2 2
4 8 -0.08 165 15.38 280 711 2.54 / 24.13 2 2
Average= 2.68
(KJ/cycle)

Cycle 7 GMT 15/ 9/2020 10: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 11 15.34 442 75 0.07 / 19.09 2 3
2 7 1418.92 39 15.09 2286 1345 1.42 / 20.43 2 2
3 13 631.56 18 15.26 1223 336 1.76 / 20.77 2 3
4 13 73.20 18 15.39 409 113 1.87 / 20.88 2 3
5 8 0.24 165 15.37 280 710 2.58 / 21.59 2 12
Average= 2.70
(KJ/cycle)

Cycle 6 GMT 5/ 9/2020 10:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 11 15.35 451 76 0.08 / 16.55 3 3
2 7 1417.92 38 15.09 2287 1311 1.39 / 17.86 2 2
3 13 647.52 18 15.26 1245 342 1.73 / 18.20 2 2
4 13 15.64 18 15.39 320 89 1.82 / 18.29 2 2
5 8 -0.20 165 15.36 286 725 2.54 / 19.02 2 3
Average= 2.72
(KJ/cycle)

Cycle 5 GMT 26/ 8/2020 11:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 10 15.33 441 68 0.07 / 13.93 3 3
2 10 1009.16 2 15.25 1801 55 0.12 / 13.98 2 3
3 7 1415.60 39 15.10 2277 1341 1.46 / 15.32 2 2
4 13 621.40 18 15.27 1201 330 1.79 / 15.65 2 2
5 13 65.40 18 15.38 389 108 1.90 / 15.76 2 2
6 8 0.16 165 15.37 280 710 2.61 / 16.47 2 3
Average= 2.75
(KJ/cycle)

Cycle 4 GMT 16/ 8/2020 12:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 11 15.33 441 74 0.07 / 11.31 2 3
2 7 1391.56 38 15.09 2242 1286 1.36 / 12.59 2 2
3 13 599.00 18 15.25 1167 320 1.68 / 12.91 2 3
4 13 57.40 18 15.38 377 104 1.78 / 13.02 2 3
5 8 0.16 165 15.36 281 712 2.50 / 13.73 2 4
6 14 0.16 30 15.34 283 130 2.63 / 13.86 2 8
Average= 2.77
(KJ/cycle)

Cycle 3 GMT 15/ 8/2020 11:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 10 15.33 462 71 0.07 / 8.02 3 3
2 3 1044.44 1 15.26 1882 29 0.10 / 8.05 2 2
3 7 1385.56 74 15.00 2220 2464 2.56 / 10.51 2 2
4 8 0.08 165 15.35 286 724 3.29 / 11.23 2 4
Average= 2.81
(KJ/cycle)

Cycle 2 GMT 14/ 8/2020 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 28 15.29 455 195 0.19 / 4.71 2 3
2 3 256.44 -14 15.59 0 0 0.00 / 4.71 2 3
3 3 877.60 -2 15.61 0 0 0.00 / 4.71 2 3
4 7 1386.20 75 14.99 2228 2505 2.70 / 7.22 2 3
5 8 0.04 165 15.34 288 729 3.43 / 7.95 2 3
Average= 2.65
(KJ/cycle)

Cycle 1 GMT 13/ 8/2020 12:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 24 15.44 437 162 0.16 / 1.84 3 3
2 3 428.28 -11 15.55 0 0 0.00 / 1.84 3 3
3 3 915.48 -2 15.56 0 0 0.00 / 1.84 3 3
4 7 1036.52 74 15.06 1750 1950 2.11 / 3.79 2 3
5 8 0.04 165 15.32 289 731 2.84 / 4.52 2 4
Average= 2.26
(KJ/cycle)

Cycle 0 GMT 13/ 8/2020 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 24 15.57 443 166 0.17 / 0.17 3 3
2 7 115.24 74 15.53 442 508 0.67 / 0.67 3 3
3 8 0.12 240 15.50 269 1001 1.67 / 1.67 3 15
Average= 1.67