SIO Argo Site:
Pump Diagnostics Page   



Serial= 8857 WMO= 5906139

Return

←PreviousNext→

Cycle 165 GMT 10/12/2024 15:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 30 14.65 1041 458 0.46 / 749.77 2 2
2 7 2003.28 39 14.52 3782 2142 2.60 / 751.91 2 2
3 13 1395.76 17 14.56 3152 780 3.38 / 752.69 2 5
4 13 811.00 17 14.63 2295 571 3.95 / 753.26 2 7
5 13 106.88 17 14.82 1168 294 4.24 / 753.56 2 3
6 8 -0.16 170 14.76 803 2015 6.26 / 755.57 2 3
Average= 4.55
(KJ/cycle)

Cycle 164 GMT 30/11/2024 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 30 14.66 1086 478 0.48 / 743.42 2 2
2 7 2005.52 39 14.48 3889 2196 2.67 / 745.61 2 3
3 13 1407.20 17 14.54 3206 792 3.47 / 746.41 2 2
4 13 822.64 17 14.62 2302 572 4.04 / 746.98 2 9
5 13 229.88 17 14.76 1424 357 4.40 / 747.33 2 7
6 8 0.00 170 14.75 789 1978 6.37 / 749.31 2 3
Average= 4.54
(KJ/cycle)

Cycle 163 GMT 21/11/2024 1:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 30 14.66 1038 457 0.46 / 737.14 2 2
2 7 2009.20 39 14.50 3851 2178 2.63 / 739.32 2 2
3 13 1275.88 17 14.55 3002 743 3.38 / 740.06 2 4
4 13 845.96 17 14.61 2346 583 3.96 / 740.64 2 7
5 13 117.64 17 14.78 1277 321 4.28 / 740.96 2 5
6 8 0.08 170 14.75 788 1976 6.26 / 742.94 2 3
Average= 4.53
(KJ/cycle)

Cycle 162 GMT 11/11/2024 6: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 30 14.66 998 439 0.44 / 730.91 2 2
2 7 2007.92 39 14.51 3776 2137 2.58 / 733.04 2 3
3 13 1391.20 17 14.56 3129 774 3.35 / 733.82 2 3
4 13 796.56 17 14.65 2219 553 3.90 / 734.37 2 9
5 13 98.28 17 14.81 1223 308 4.21 / 734.68 2 3
6 8 0.24 170 14.75 800 2006 6.22 / 736.68 2 4
Average= 4.52
(KJ/cycle)

Cycle 161 GMT 1/11/2024 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 30 14.66 1019 448 0.45 / 724.67 2 2
2 7 2006.28 40 14.52 3783 2197 2.65 / 726.86 2 3
3 13 1381.96 17 14.56 3138 777 3.42 / 727.64 2 3
4 13 800.00 17 14.64 2213 551 3.97 / 728.19 2 9
5 13 101.00 17 14.81 1188 299 4.27 / 728.49 2 4
6 8 0.00 170 14.75 788 1976 6.25 / 730.47 2 4
Average= 4.51
(KJ/cycle)

Cycle 160 GMT 22/10/2024 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 30 14.67 1020 449 0.45 / 718.43 2 2
2 7 2004.80 39 14.50 3828 2165 2.61 / 720.59 2 3
3 13 1400.52 17 14.54 3198 790 3.40 / 721.38 2 3
4 13 807.76 17 14.65 2229 555 3.96 / 721.94 2 7
5 13 105.76 17 14.82 1172 295 4.25 / 722.23 2 5
6 8 0.16 170 14.76 791 1985 6.24 / 724.22 2 3
Average= 4.50
(KJ/cycle)

Cycle 159 GMT 12/10/2024 20:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 30 14.67 1021 449 0.45 / 712.17 2 2
2 7 2002.56 39 14.52 3792 2147 2.60 / 714.32 2 3
3 13 1409.56 17 14.57 3169 785 3.38 / 715.11 2 3
4 13 836.88 17 14.64 2286 569 3.95 / 715.67 2 9
5 13 130.52 17 14.82 1210 305 4.26 / 715.98 2 4
6 8 0.24 170 14.76 797 2000 6.26 / 717.98 2 3
Average= 4.49
(KJ/cycle)

Cycle 158 GMT 3/10/2024 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 14.68 993 437 0.44 / 705.96 2 2
2 7 2001.16 40 14.54 3729 2169 2.61 / 708.13 2 3
3 13 1388.60 17 14.58 3049 756 3.36 / 708.88 2 3
4 13 813.56 17 14.66 2204 549 3.91 / 709.43 2 11
5 13 49.88 17 14.85 1098 277 4.19 / 709.71 2 3
6 8 -0.08 170 14.77 802 2014 6.20 / 711.72 2 3
Average= 4.48
(KJ/cycle)

Cycle 157 GMT 23/ 9/2024 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 30 14.71 980 432 0.43 / 700.24 2 2
2 7 1728.36 39 14.61 3381 1926 2.36 / 702.17 2 3
3 13 1299.40 17 14.64 2875 716 3.07 / 702.88 2 4
4 13 854.96 17 14.69 2192 547 3.62 / 703.43 2 8
5 13 26.32 17 14.87 970 245 3.87 / 703.67 2 3
6 8 -0.08 170 14.79 735 1848 5.72 / 705.52 2 3
Average= 4.47
(KJ/cycle)

Cycle 156 GMT 13/ 9/2024 8:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 30 14.71 981 433 0.43 / 694.78 2 2
2 7 1615.88 39 14.65 3224 1842 2.27 / 696.63 2 3
3 13 1213.64 17 14.66 2857 712 2.99 / 697.34 2 3
4 13 782.68 17 14.71 2166 542 3.53 / 697.88 2 9
5 8 0.24 170 14.81 765 1926 5.45 / 699.81 2 3
Average= 4.46
(KJ/cycle)

Cycle 155 GMT 3/ 9/2024 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 30 14.71 948 418 0.42 / 689.42 2 2
2 7 1536.24 39 14.67 3106 1777 2.20 / 691.20 2 3
3 13 1271.28 17 14.65 3008 749 2.94 / 691.95 2 3
4 13 695.92 17 14.74 2078 521 3.47 / 692.47 2 9
5 8 0.08 170 14.82 747 1882 5.35 / 694.35 2 6
Average= 4.45
(KJ/cycle)

Cycle 154 GMT 24/ 8/2024 14:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 30 14.67 999 440 0.44 / 683.85 2 2
2 7 1403.68 39 14.75 2970 1708 2.15 / 685.56 2 3
3 13 1275.24 17 14.72 2900 726 2.87 / 686.29 2 5
4 13 681.28 17 14.77 2040 512 3.39 / 686.80 2 8
5 13 99.60 17 14.87 1162 294 3.68 / 687.09 2 3
6 8 -0.08 170 14.82 759 1912 5.59 / 689.00 2 3
Average= 4.45
(KJ/cycle)

Cycle 153 GMT 14/ 8/2024 17:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 30 14.68 967 426 0.43 / 678.22 2 2
2 7 1516.44 39 14.69 3123 1789 2.22 / 680.01 2 3
3 13 1256.88 17 14.69 2863 715 2.93 / 680.72 2 4
4 13 694.16 17 14.77 2001 502 3.43 / 681.22 2 10
5 13 55.92 17 14.89 991 251 3.68 / 681.48 2 3
6 8 0.16 170 14.80 770 1937 5.62 / 683.41 2 3
Average= 4.44
(KJ/cycle)

Cycle 152 GMT 4/ 8/2024 20:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 30 14.65 1035 455 0.45 / 672.12 2 2
2 7 2003.72 40 14.54 3749 2180 2.64 / 674.30 2 3
3 13 1273.52 17 14.58 2933 727 3.36 / 675.03 2 3
4 13 849.72 17 14.65 2243 559 3.92 / 675.59 2 9
5 13 119.20 17 14.82 1190 300 4.22 / 675.89 2 3
6 8 -0.08 170 14.78 758 1905 6.13 / 677.79 2 3
Average= 4.43
(KJ/cycle)

Cycle 151 GMT 26/ 7/2024 1:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 14.68 1000 440 0.44 / 665.96 2 2
2 7 2010.48 39 14.54 3819 2166 2.61 / 668.13 2 3
3 13 1283.60 17 14.58 2954 732 3.34 / 668.86 2 4
4 13 860.96 17 14.65 2238 557 3.90 / 669.42 2 7
5 13 123.80 17 14.82 1134 286 4.18 / 669.70 2 6
6 8 0.24 170 14.76 782 1962 6.14 / 671.67 2 6
Average= 4.42
(KJ/cycle)

Cycle 150 GMT 16/ 7/2024 6:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 30 14.70 993 438 0.44 / 659.83 2 2
2 7 2004.48 39 14.54 3747 2125 2.56 / 661.95 2 3
3 13 1391.28 17 14.58 3086 765 3.33 / 662.72 2 5
4 13 814.68 17 14.67 2229 556 3.88 / 663.27 2 9
5 13 111.24 17 14.82 1162 293 4.18 / 663.56 2 4
6 8 -0.08 170 14.77 780 1959 6.13 / 665.52 2 3
Average= 4.41
(KJ/cycle)

Cycle 149 GMT 6/ 7/2024 11:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 30 14.68 979 431 0.43 / 653.81 2 2
2 7 2003.16 39 14.55 3724 2113 2.54 / 655.93 2 3
3 13 1388.56 17 14.59 3021 749 3.29 / 656.68 2 3
4 13 809.92 17 14.70 2134 533 3.83 / 657.21 2 8
5 13 103.24 17 14.86 1057 267 4.09 / 657.48 2 3
6 8 0.12 170 14.79 761 1913 6.01 / 659.39 2 4
Average= 4.40
(KJ/cycle)

Cycle 148 GMT 26/ 6/2024 16:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 30 14.69 998 440 0.44 / 647.75 2 2
2 7 2007.96 39 14.55 3720 2111 2.55 / 649.86 2 2
3 13 1281.76 17 14.61 2897 720 3.27 / 650.58 2 4
4 13 853.32 17 14.68 2229 556 3.83 / 651.13 2 8
5 13 117.36 17 14.83 1136 286 4.11 / 651.42 2 5
6 8 0.40 170 14.78 781 1962 6.08 / 653.38 2 4
Average= 4.39
(KJ/cycle)

Cycle 147 GMT 16/ 6/2024 21:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 30 14.71 929 410 0.41 / 641.77 2 2
2 7 2004.24 39 14.59 3658 2081 2.49 / 643.85 2 2
3 13 1404.96 17 14.62 2964 737 3.23 / 644.59 2 3
4 13 833.08 17 14.70 2122 530 3.76 / 645.12 2 6
5 13 237.52 17 14.82 1320 333 4.09 / 645.45 2 3
6 8 -0.20 170 14.80 738 1857 5.95 / 647.31 2 3
Average= 4.37
(KJ/cycle)

Cycle 146 GMT 7/ 6/2024 2:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 30 14.72 930 411 0.41 / 635.96 2 3
2 7 2003.96 39 14.58 3630 2064 2.47 / 638.03 2 3
3 13 1396.68 17 14.63 2923 727 3.20 / 638.75 2 2
4 13 700.28 17 14.74 1933 484 3.69 / 639.24 2 9
5 13 60.80 17 14.87 983 248 3.93 / 639.49 2 2
6 8 0.20 170 14.79 744 1871 5.81 / 641.36 2 5
Average= 4.36
(KJ/cycle)

Cycle 145 GMT 28/ 5/2024 7:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 29 14.73 903 386 0.39 / 630.27 2 2
2 7 2007.32 39 14.57 3643 2070 2.46 / 632.34 2 3
3 13 1269.80 17 14.64 2732 680 3.14 / 633.02 2 3
4 13 841.68 17 14.70 2071 518 3.65 / 633.54 2 6
5 13 113.28 17 14.86 1028 260 3.91 / 633.80 2 3
6 8 0.08 170 14.80 698 1756 5.67 / 635.55 2 4
Average= 4.35
(KJ/cycle)

Cycle 144 GMT 18/ 5/2024 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 29 14.75 903 386 0.39 / 624.61 2 2
2 7 2002.84 39 14.60 3553 2023 2.41 / 626.63 2 3
3 13 1271.24 17 14.66 2720 678 3.09 / 627.31 2 4
4 13 847.92 17 14.71 2069 517 3.60 / 627.83 2 6
5 13 117.76 17 14.88 1013 256 3.86 / 628.09 2 6
6 8 0.00 170 14.82 714 1799 5.66 / 629.88 2 3
Average= 4.34
(KJ/cycle)

Cycle 143 GMT 8/ 5/2024 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 29 14.75 839 359 0.36 / 619.00 2 2
2 7 2002.72 39 14.59 3618 2059 2.42 / 621.06 2 3
3 13 1402.04 17 14.65 2864 713 3.13 / 621.78 2 3
4 13 809.12 17 14.74 2021 506 3.64 / 622.28 2 10
5 13 110.00 17 14.89 1036 262 3.90 / 622.55 2 3
6 8 0.04 170 14.83 666 1679 5.58 / 624.22 2 4
Average= 4.33
(KJ/cycle)

Cycle 142 GMT 28/ 4/2024 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 14.75 867 371 0.37 / 613.55 2 2
2 7 2011.48 39 14.59 3563 2027 2.40 / 615.58 2 3
3 13 1387.08 17 14.65 2845 709 3.11 / 616.28 2 3
4 13 798.12 17 14.72 2014 504 3.61 / 616.79 2 7
5 13 63.72 17 14.89 860 218 3.83 / 617.01 2 3
6 8 0.24 170 14.84 650 1640 5.47 / 618.65 2 3
Average= 4.33
(KJ/cycle)

Cycle 141 GMT 19/ 4/2024 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 29 14.74 871 372 0.37 / 607.91 2 2
2 7 2005.08 39 14.60 3571 2033 2.41 / 609.94 2 3
3 13 1394.36 17 14.65 2885 719 3.12 / 610.66 2 2
4 13 932.00 17 14.69 2178 544 3.67 / 611.21 2 6
5 13 182.36 17 14.86 1099 278 3.95 / 611.48 2 5
6 8 0.12 170 14.83 672 1694 5.64 / 613.18 2 3
Average= 4.32
(KJ/cycle)

Cycle 140 GMT 9/ 4/2024 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 29 14.75 1056 452 0.45 / 602.45 2 2
2 7 2005.48 40 14.61 3506 2049 2.50 / 604.50 2 2
3 13 1283.44 17 14.68 2642 659 3.16 / 605.15 2 2
4 13 863.44 17 14.73 1991 499 3.66 / 605.65 2 5
5 13 121.72 17 14.89 986 250 3.91 / 605.90 2 3
6 8 0.00 170 14.84 648 1635 5.54 / 607.54 2 3
Average= 4.31
(KJ/cycle)

Cycle 139 GMT 30/ 3/2024 12:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 29 14.77 802 344 0.34 / 596.90 2 2
2 7 2002.76 39 14.63 3497 1995 2.34 / 598.89 2 3
3 13 1412.76 17 14.68 2789 696 3.03 / 599.59 2 3
4 13 954.28 17 14.73 2122 531 3.57 / 600.12 2 3
5 13 194.40 17 14.88 1051 266 3.83 / 600.39 2 5
6 8 0.04 170 14.84 638 1610 5.44 / 601.99 2 3
Average= 4.30
(KJ/cycle)

Cycle 138 GMT 20/ 3/2024 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 29 14.75 831 355 0.36 / 591.14 2 2
2 7 2002.84 40 14.62 3523 2060 2.42 / 593.20 2 3
3 13 1274.88 17 14.69 2646 661 3.08 / 593.86 2 3
4 13 726.64 17 14.77 1828 459 3.54 / 594.32 2 8
5 13 259.52 17 14.85 1190 300 3.84 / 594.62 2 4
6 8 0.12 170 14.83 658 1659 5.49 / 596.28 2 4
7 14 0.12 25 14.76 743 274 5.77 / 596.55 2 3
Average= 4.29
(KJ/cycle)

Cycle 137 GMT 10/ 3/2024 22:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 29 14.74 839 359 0.36 / 585.62 2 2
2 7 2007.80 39 14.61 3557 2027 2.39 / 587.65 2 3
3 13 1289.72 17 14.68 2678 668 3.05 / 588.32 2 3
4 13 865.80 17 14.73 2019 506 3.56 / 588.82 2 6
5 13 64.36 17 14.89 905 229 3.79 / 589.05 2 4
6 8 0.36 170 14.83 687 1732 5.52 / 590.78 2 6
Average= 4.28
(KJ/cycle)

Cycle 136 GMT 1/ 3/2024 3:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 29 14.78 793 340 0.34 / 580.11 2 2
2 7 2004.80 39 14.62 3504 1998 2.34 / 582.11 2 3
3 13 1390.00 17 14.69 2720 679 3.02 / 582.79 2 5
4 13 942.16 17 14.72 2083 521 3.54 / 583.31 2 5
5 13 156.24 17 14.88 1017 257 3.80 / 583.57 2 3
6 8 -0.04 170 14.83 673 1697 5.49 / 585.26 2 3
Average= 4.27
(KJ/cycle)

Cycle 135 GMT 20/ 2/2024 8:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 29 14.79 764 328 0.33 / 574.84 2 2
2 7 2007.64 39 14.63 3474 1982 2.31 / 576.82 2 3
3 13 1279.84 17 14.72 2543 636 2.95 / 577.46 2 3
4 13 855.76 17 14.76 1915 481 3.43 / 577.94 2 7
5 13 66.76 17 14.92 897 228 3.65 / 578.16 2 2
6 8 0.04 170 14.86 636 1607 5.26 / 579.77 2 4
Average= 4.26
(KJ/cycle)

Cycle 134 GMT 10/ 2/2024 13: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 29 14.75 935 400 0.40 / 569.64 2 2
2 7 2002.80 39 14.62 3463 1975 2.37 / 571.61 2 3
3 13 1392.40 17 14.69 2697 674 3.05 / 572.29 2 3
4 13 801.52 17 14.78 1847 464 3.51 / 572.75 2 9
5 13 100.04 17 14.92 893 227 3.74 / 572.98 2 3
6 8 0.16 170 14.86 607 1533 5.27 / 574.51 2 3
Average= 4.26
(KJ/cycle)

Cycle 133 GMT 31/ 1/2024 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 29 14.79 758 325 0.33 / 564.39 2 2
2 7 2004.16 40 14.63 3454 2021 2.35 / 566.41 2 3
3 13 1264.08 17 14.72 2545 637 2.98 / 567.05 2 3
4 13 846.68 17 14.77 1900 477 3.46 / 567.52 2 7
5 13 55.64 17 14.92 803 204 3.66 / 567.73 2 2
6 8 0.08 170 14.86 598 1511 5.17 / 569.24 2 8
Average= 4.25
(KJ/cycle)

Cycle 132 GMT 21/ 1/2024 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 29 14.78 768 329 0.33 / 559.32 2 2
2 7 2002.92 39 14.65 3427 1958 2.29 / 561.28 2 2
3 13 1268.64 17 14.72 2520 631 2.92 / 561.91 2 3
4 13 835.16 17 14.77 1881 472 3.39 / 562.38 2 7
5 13 55.44 17 14.92 788 200 3.59 / 562.58 2 3
6 8 -0.16 170 14.86 586 1480 5.07 / 564.06 2 3
Average= 4.24
(KJ/cycle)

Cycle 131 GMT 11/ 1/2024 22:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 29 14.81 761 327 0.33 / 554.26 2 2
2 7 2005.32 39 14.64 3453 1972 2.30 / 556.23 2 3
3 13 1265.76 17 14.73 2499 626 2.92 / 556.85 2 3
4 13 709.04 17 14.80 1734 436 3.36 / 557.29 2 9
5 13 61.48 17 14.93 841 213 3.57 / 557.50 2 4
6 8 0.04 170 14.87 589 1489 5.06 / 558.99 2 4
Average= 4.23
(KJ/cycle)

Cycle 130 GMT 2/ 1/2024 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 29 14.82 732 315 0.31 / 549.19 2 2
2 7 2004.96 39 14.66 3407 1948 2.26 / 551.14 2 2
3 13 1384.40 17 14.72 2676 670 2.93 / 551.81 2 3
4 13 797.20 17 14.81 1808 455 3.39 / 552.26 2 10
5 13 56.20 17 14.93 786 199 3.59 / 552.46 2 5
6 8 0.24 170 14.88 580 1467 5.05 / 553.93 2 3
Average= 4.23
(KJ/cycle)

Cycle 129 GMT 23/12/2023 2:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 29 14.81 715 307 0.31 / 544.24 2 2
2 7 2007.16 39 14.66 3397 1942 2.25 / 546.18 2 2
3 13 1275.64 17 14.73 2501 626 2.88 / 546.81 2 3
4 13 720.80 17 14.81 1716 432 3.31 / 547.24 2 6
5 13 68.28 17 14.95 783 199 3.51 / 547.44 2 3
6 8 0.00 170 14.89 569 1440 4.95 / 548.88 2 4
Average= 4.22
(KJ/cycle)

Cycle 128 GMT 13/12/2023 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 29 14.82 766 329 0.33 / 539.19 2 2
2 7 2009.24 39 14.65 3410 1948 2.28 / 541.13 2 3
3 13 1408.20 17 14.69 2716 678 2.96 / 541.81 2 3
4 13 806.36 17 14.78 1838 462 3.42 / 542.27 2 7
5 13 93.92 17 14.92 882 224 3.64 / 542.50 2 6
6 8 -0.08 170 14.88 566 1432 5.07 / 543.93 2 3
Average= 4.22
(KJ/cycle)

Cycle 127 GMT 3/12/2023 7:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 29 14.83 761 327 0.33 / 533.98 2 2
2 7 2006.56 39 14.67 3420 1957 2.28 / 535.94 2 2
3 13 1271.44 17 14.72 2528 633 2.92 / 536.57 2 3
4 13 724.08 17 14.81 1702 429 3.35 / 537.00 2 9
5 13 146.36 17 14.93 863 219 3.56 / 537.22 2 3
6 8 0.08 170 14.89 554 1402 4.97 / 538.62 2 2
7 14 0.08 25 14.84 644 239 5.21 / 538.86 2 4
Average= 4.21
(KJ/cycle)

Cycle 126 GMT 23/11/2023 9:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 29 14.85 761 328 0.33 / 529.09 2 2
2 7 2003.12 39 14.67 3356 1920 2.25 / 531.01 2 3
3 13 1264.44 17 14.75 2427 609 2.86 / 531.62 2 4
4 13 836.52 17 14.79 1816 457 3.31 / 532.08 2 5
5 13 54.00 17 14.95 722 183 3.50 / 532.26 2 3
6 8 0.12 170 14.90 548 1388 4.88 / 533.65 2 3
Average= 4.20
(KJ/cycle)

Cycle 125 GMT 13/11/2023 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 29 14.82 735 316 0.32 / 524.35 2 2
2 7 2010.00 39 14.65 3410 1948 2.26 / 526.30 2 2
3 13 1393.44 17 14.72 2621 656 2.92 / 526.96 2 3
4 13 694.04 17 14.83 1631 411 3.33 / 527.37 2 6
5 8 0.12 170 14.92 551 1398 4.73 / 528.77 2 3
Average= 4.20
(KJ/cycle)

Cycle 124 GMT 3/11/2023 13:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 29 14.83 689 296 0.30 / 519.46 2 2
2 7 2004.80 39 14.65 3375 1928 2.22 / 521.38 2 2
3 13 1275.84 17 14.74 2457 616 2.84 / 522.00 2 3
4 13 722.08 17 14.81 1675 422 3.26 / 522.42 2 11
5 13 30.12 17 14.96 690 175 3.44 / 522.60 2 3
6 8 0.08 170 14.89 569 1440 4.88 / 524.04 2 3
Average= 4.19
(KJ/cycle)

Cycle 123 GMT 24/10/2023 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 29 14.85 704 303 0.30 / 514.64 2 3
2 7 2003.76 39 14.66 3388 1937 2.24 / 516.58 2 3
3 13 1262.20 17 14.75 2439 612 2.85 / 517.19 2 3
4 13 830.84 17 14.80 1808 455 3.31 / 517.64 2 11
5 13 50.28 17 14.97 692 176 3.48 / 517.82 2 5
6 8 0.20 170 14.91 529 1341 4.82 / 519.16 2 5
Average= 4.19
(KJ/cycle)

Cycle 122 GMT 14/10/2023 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 29 14.85 694 299 0.30 / 509.90 2 2
2 7 2005.04 39 14.67 3349 1916 2.21 / 511.82 2 2
3 13 1274.48 17 14.76 2424 608 2.82 / 512.43 2 3
4 13 718.52 17 14.84 1631 411 3.23 / 512.84 2 10
5 13 67.40 17 14.97 688 175 3.41 / 513.02 2 3
6 8 -0.28 170 14.92 521 1321 4.73 / 514.34 2 4
Average= 4.18
(KJ/cycle)

Cycle 121 GMT 4/10/2023 19:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 14.86 698 301 0.30 / 505.10 2 2
2 7 2010.40 39 14.67 3373 1930 2.23 / 507.03 2 3
3 13 1390.60 17 14.74 2575 645 2.88 / 507.67 2 5
4 13 806.64 17 14.81 1767 445 3.32 / 508.12 2 9
5 13 23.12 17 14.98 630 160 3.48 / 508.28 2 2
6 8 0.12 170 14.92 523 1327 4.81 / 509.61 2 3
Average= 4.18
(KJ/cycle)

Cycle 120 GMT 24/ 9/2023 21:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 29 14.85 743 320 0.32 / 500.39 2 2
2 7 2004.68 39 14.67 3335 1908 2.23 / 502.30 2 3
3 13 1266.40 17 14.77 2374 596 2.82 / 502.90 2 3
4 13 720.36 17 14.84 1616 408 3.23 / 503.30 2 9
5 13 63.88 17 14.98 686 175 3.41 / 503.48 2 8
6 8 0.04 170 14.92 520 1319 4.73 / 504.80 2 4
Average= 4.17
(KJ/cycle)

Cycle 119 GMT 15/ 9/2023 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 29 14.86 724 312 0.31 / 495.63 2 3
2 7 2004.52 39 14.67 3360 1922 2.23 / 497.56 2 3
3 13 1389.68 17 14.76 2541 638 2.87 / 498.19 2 3
4 13 796.44 17 14.83 1701 429 3.30 / 498.62 2 7
5 13 51.68 17 14.99 622 159 3.46 / 498.78 2 4
6 8 0.12 170 14.93 509 1292 4.75 / 500.07 2 10
Average= 4.17
(KJ/cycle)

Cycle 118 GMT 5/ 9/2023 2:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 29 14.86 702 303 0.30 / 490.90 2 3
2 7 2004.08 39 14.68 3363 1925 2.23 / 492.83 2 3
3 13 1274.68 17 14.76 2389 599 2.83 / 493.43 2 3
4 13 719.20 17 14.84 1606 405 3.23 / 493.83 2 11
5 13 30.32 17 15.00 567 145 3.38 / 493.98 2 3
6 8 -0.04 170 14.92 530 1344 4.72 / 495.32 2 2
Average= 4.16
(KJ/cycle)

Cycle 117 GMT 26/ 8/2023 4:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 29 14.85 693 298 0.30 / 486.20 2 2
2 7 2004.68 39 14.68 3304 1892 2.19 / 488.09 2 3
3 13 1273.36 17 14.77 2375 596 2.79 / 488.68 2 3
4 13 834.40 17 14.81 1742 439 3.22 / 489.12 2 6
5 13 58.08 17 14.98 642 163 3.39 / 489.29 2 5
6 8 0.20 170 14.92 518 1314 4.70 / 490.60 2 3
Average= 4.16
(KJ/cycle)

Cycle 116 GMT 16/ 8/2023 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 29 14.87 683 295 0.29 / 481.30 2 3
2 7 2007.84 39 14.69 3308 1895 2.19 / 483.19 2 3
3 13 1399.80 17 14.75 2535 636 2.83 / 483.83 2 3
4 13 808.12 17 14.84 1709 431 3.26 / 484.26 2 6
5 13 44.92 17 15.00 614 157 3.41 / 484.42 2 4
6 8 -0.08 170 14.93 506 1284 4.70 / 485.70 2 3
7 14 -0.08 25 14.89 532 198 4.90 / 485.90 4 3
Average= 4.15
(KJ/cycle)

Cycle 115 GMT 6/ 8/2023 8:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 14.87 683 295 0.29 / 476.66 2 3
2 7 2004.04 39 14.69 3310 1896 2.19 / 478.56 2 3
3 13 1388.36 17 14.78 2515 632 2.82 / 479.19 2 3
4 13 680.00 17 14.86 1528 386 3.21 / 479.58 2 8
5 13 28.16 17 15.00 569 145 3.35 / 479.72 2 3
6 8 0.12 170 14.94 504 1280 4.63 / 481.00 2 3
Average= 4.15
(KJ/cycle)

Cycle 114 GMT 27/ 7/2023 10:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 14.87 686 296 0.30 / 472.06 2 2
2 7 2006.60 39 14.70 3302 1893 2.19 / 473.96 2 2
3 13 1399.76 17 14.76 2513 631 2.82 / 474.59 2 4
4 13 801.24 17 14.84 1686 425 3.24 / 475.01 2 10
5 13 19.76 17 15.00 537 137 3.38 / 475.15 2 3
6 8 0.08 170 14.94 480 1219 4.60 / 476.37 2 3
Average= 4.14
(KJ/cycle)

Cycle 113 GMT 17/ 7/2023 13: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 29 14.86 695 300 0.30 / 467.39 2 2
2 7 2007.04 39 14.68 3330 1906 2.21 / 469.30 2 3
3 13 1254.92 17 14.77 2366 594 2.80 / 469.89 2 3
4 13 696.16 17 14.85 1584 400 3.20 / 470.29 2 7
5 13 114.36 17 14.96 760 193 3.39 / 470.49 2 3
6 8 0.24 170 14.93 505 1282 4.67 / 471.77 2 2
Average= 4.14
(KJ/cycle)

Cycle 112 GMT 7/ 7/2023 15:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 29 14.87 675 291 0.29 / 462.66 2 3
2 7 2008.08 39 14.70 3304 1894 2.19 / 464.55 2 2
3 13 1400.68 17 14.76 2520 632 2.82 / 465.18 2 3
4 13 814.20 17 14.83 1709 431 3.25 / 465.62 2 6
5 13 50.44 17 14.98 641 163 3.41 / 465.78 2 2
6 8 -0.04 170 14.92 518 1314 4.73 / 467.09 2 2
Average= 4.13
(KJ/cycle)

Cycle 111 GMT 27/ 6/2023 17:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 29 14.87 666 287 0.29 / 457.97 2 2
2 7 2005.56 39 14.70 3291 1887 2.17 / 459.86 2 2
3 13 1411.08 17 14.78 2522 634 2.81 / 460.50 2 3
4 13 835.60 17 14.84 1731 437 3.24 / 460.93 2 5
5 13 110.68 17 14.97 721 183 3.43 / 461.12 2 3
6 8 0.00 170 14.93 493 1251 4.68 / 462.37 2 6
Average= 4.13
(KJ/cycle)

Cycle 110 GMT 17/ 6/2023 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 29 14.88 686 296 0.30 / 453.44 2 2
2 7 2003.68 39 14.70 3292 1887 2.18 / 455.33 2 3
3 13 1272.08 17 14.80 2326 585 2.77 / 455.91 2 3
4 13 721.56 17 14.87 1573 398 3.17 / 456.31 2 8
5 13 66.88 17 14.98 647 165 3.33 / 456.48 2 2
6 8 -0.04 170 14.94 477 1211 4.54 / 457.69 2 3
Average= 4.12
(KJ/cycle)

Cycle 109 GMT 7/ 6/2023 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 29 14.87 664 286 0.29 / 448.90 2 2
2 7 2003.08 39 14.71 3283 1883 2.17 / 450.78 2 2
3 13 1257.04 17 14.80 2299 578 2.75 / 451.36 2 3
4 13 817.84 17 14.85 1691 427 3.18 / 451.79 2 6
5 13 51.08 17 15.00 614 157 3.33 / 451.95 2 3
6 8 0.32 170 14.95 472 1200 4.53 / 453.15 2 2
Average= 4.12
(KJ/cycle)

Cycle 108 GMT 29/ 5/2023 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 29 14.88 681 294 0.29 / 444.29 2 2
2 7 2009.88 39 14.70 3293 1888 2.18 / 446.18 2 3
3 13 1402.84 17 14.78 2542 639 2.82 / 446.82 2 3
4 13 689.88 17 14.87 1528 386 3.21 / 447.21 2 7
5 13 116.68 17 14.99 712 181 3.39 / 447.39 2 3
6 8 0.20 170 14.94 483 1227 4.61 / 448.61 2 5
Average= 4.12
(KJ/cycle)

Cycle 107 GMT 19/ 5/2023 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 29 14.88 659 284 0.28 / 439.67 2 2
2 7 2002.80 40 14.72 3282 1932 2.22 / 441.60 2 3
3 13 1394.48 17 14.78 2491 626 2.84 / 442.23 2 3
4 13 688.40 17 14.88 1525 386 3.23 / 442.61 2 6
5 13 64.72 17 15.00 648 165 3.39 / 442.78 2 3
6 8 0.16 170 14.95 481 1222 4.62 / 444.00 2 3
Average= 4.11
(KJ/cycle)

Cycle 106 GMT 9/ 5/2023 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 29 14.89 636 275 0.27 / 435.06 2 2
2 7 2008.32 39 14.71 3279 1881 2.16 / 436.94 2 3
3 13 1397.60 17 14.78 2496 627 2.78 / 437.57 2 4
4 13 795.48 17 14.86 1672 422 3.21 / 437.99 2 7
5 13 101.12 17 15.00 657 168 3.37 / 438.16 2 2
6 8 -0.08 170 14.94 483 1227 4.60 / 439.38 2 4
Average= 4.11
(KJ/cycle)

Cycle 105 GMT 29/ 4/2023 6:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 29 14.88 689 297 0.30 / 430.49 2 2
2 7 2009.16 39 14.70 3309 1897 2.19 / 432.39 2 2
3 13 1282.40 17 14.79 2381 599 2.79 / 432.98 2 4
4 13 708.28 17 14.87 1579 399 3.19 / 433.38 2 10
5 13 69.68 17 15.01 646 165 3.36 / 433.55 2 4
6 8 0.04 170 14.95 486 1235 4.59 / 434.78 2 3
Average= 4.10
(KJ/cycle)

Cycle 104 GMT 19/ 4/2023 8:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 29 14.88 663 286 0.29 / 425.89 2 2
2 7 2006.32 39 14.71 3284 1884 2.17 / 427.77 2 3
3 13 1269.40 17 14.81 2327 586 2.76 / 428.36 2 3
4 13 846.52 17 14.85 1739 439 3.19 / 428.79 2 4
5 13 61.28 17 15.01 612 156 3.35 / 428.95 2 3
6 8 0.40 170 14.95 488 1240 4.59 / 430.19 2 3
Average= 4.10
(KJ/cycle)

Cycle 103 GMT 9/ 4/2023 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 29 14.90 631 273 0.27 / 421.26 2 2
2 7 2008.08 40 14.71 3264 1921 2.19 / 423.18 2 2
3 13 1264.68 17 14.80 2306 580 2.77 / 423.76 2 3
4 13 841.36 17 14.84 1724 435 3.21 / 424.20 2 5
5 13 100.64 17 14.98 683 174 3.38 / 424.37 2 3
6 8 -0.12 170 14.93 484 1228 4.61 / 425.60 2 3
Average= 4.09
(KJ/cycle)

Cycle 102 GMT 30/ 3/2023 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 29 14.88 682 294 0.29 / 416.74 2 2
2 7 2009.92 39 14.71 3293 1889 2.18 / 418.63 2 2
3 13 1405.16 17 14.78 2499 628 2.81 / 419.25 2 3
4 13 693.04 17 14.88 1531 387 3.20 / 419.64 2 8
5 13 58.92 17 15.01 607 155 3.35 / 419.80 2 4
6 8 -0.16 170 14.96 469 1193 4.55 / 420.99 2 3
Average= 4.09
(KJ/cycle)

Cycle 101 GMT 20/ 3/2023 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 29 14.87 694 299 0.30 / 412.02 2 2
2 7 2004.48 39 14.72 3261 1872 2.17 / 413.89 2 3
3 13 1278.20 17 14.79 2318 583 2.75 / 414.47 2 3
4 13 719.64 17 14.87 1568 396 3.15 / 414.87 2 6
5 13 62.88 17 15.01 635 162 3.31 / 415.03 2 3
6 8 0.20 170 14.95 485 1233 4.55 / 416.26 2 3
7 14 0.20 25 14.91 486 181 4.73 / 416.44 2 4
Average= 4.08
(KJ/cycle)

Cycle 100 GMT 10/ 3/2023 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 29 14.88 703 303 0.30 / 407.34 2 2
2 7 2003.48 39 14.72 3308 1899 2.20 / 409.24 2 2
3 13 1546.28 17 14.76 2715 681 2.88 / 409.92 2 3
4 13 677.40 17 14.90 1525 386 3.27 / 410.30 2 6
5 13 111.68 17 15.00 704 180 3.45 / 410.48 2 3
6 8 0.16 170 14.95 485 1233 4.68 / 411.72 2 3
Average= 4.08
(KJ/cycle)

Cycle 99 GMT 28/ 2/2023 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 29 14.90 641 277 0.28 / 402.64 2 2
2 7 2009.88 39 14.71 3282 1883 2.16 / 404.52 2 2
3 13 1383.64 17 14.79 2496 628 2.79 / 405.15 2 3
4 13 921.08 17 14.84 1826 461 3.25 / 405.61 2 4
5 13 136.92 17 15.00 755 193 3.44 / 405.80 2 3
6 8 -0.12 170 14.96 484 1231 4.67 / 407.03 2 3
Average= 4.07
(KJ/cycle)

Cycle 98 GMT 18/ 2/2023 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 29 14.89 643 278 0.28 / 398.15 2 2
2 7 2008.04 39 14.72 3268 1876 2.15 / 400.02 2 2
3 13 1305.96 17 14.81 2347 591 2.74 / 400.61 2 3
4 13 745.04 17 14.88 1577 399 3.14 / 401.01 2 5
5 13 45.08 17 15.01 568 145 3.29 / 401.16 2 3
6 8 0.12 170 14.95 474 1205 4.49 / 402.36 2 4
Average= 4.06
(KJ/cycle)

Cycle 97 GMT 9/ 2/2023 0:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 29 14.89 659 285 0.28 / 393.61 2 2
2 7 2003.68 39 14.72 3258 1870 2.15 / 395.48 2 3
3 13 1265.76 17 14.81 2309 581 2.74 / 396.06 2 3
4 13 830.16 17 14.86 1695 428 3.16 / 396.49 2 4
5 13 56.64 17 15.02 588 150 3.31 / 396.64 2 2
6 8 0.12 170 14.95 484 1230 4.54 / 397.87 2 3
Average= 4.06
(KJ/cycle)

Cycle 96 GMT 30/ 1/2023 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 29 14.87 682 294 0.29 / 389.01 2 2
2 7 2003.72 39 14.72 3252 1867 2.16 / 390.88 2 3
3 13 1376.64 17 14.80 2450 616 2.78 / 391.50 2 3
4 13 777.92 17 14.90 1620 410 3.19 / 391.91 2 4
5 13 184.88 17 15.01 779 199 3.39 / 392.11 2 4
6 8 -0.04 170 14.97 479 1219 4.61 / 393.33 2 3
Average= 4.05
(KJ/cycle)

Cycle 95 GMT 20/ 1/2023 4:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 14.90 655 283 0.28 / 384.25 2 2
2 7 2002.88 39 14.72 3238 1859 2.14 / 386.11 2 3
3 13 1384.64 17 14.79 2452 617 2.76 / 386.73 2 3
4 13 785.68 17 14.88 1636 414 3.17 / 387.14 2 6
5 13 91.84 17 15.02 635 162 3.33 / 387.30 2 3
6 8 0.16 170 14.96 483 1228 4.56 / 388.53 2 3
7 14 0.16 25 14.91 500 186 4.75 / 388.72 2 6
Average= 4.05
(KJ/cycle)

Cycle 94 GMT 10/ 1/2023 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 29 14.91 626 271 0.27 / 379.85 2 2
2 7 2006.96 39 14.73 3229 1855 2.13 / 381.71 2 2
3 13 1264.80 17 14.82 2274 573 2.70 / 382.28 2 3
4 13 708.96 17 14.90 1505 381 3.08 / 382.66 2 6
5 13 35.48 17 15.04 521 133 3.21 / 382.80 2 2
6 8 -0.08 170 14.97 461 1173 4.39 / 383.97 2 3
Average= 4.04
(KJ/cycle)

Cycle 93 GMT 31/12/2022 9: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 14.92 641 268 0.27 / 375.50 2 2
2 7 2002.96 39 14.73 3233 1857 2.13 / 377.36 2 2
3 13 1257.40 17 14.82 2248 566 2.69 / 377.92 2 4
4 13 695.56 17 14.89 1489 377 3.07 / 378.30 2 7
5 13 34.44 17 15.04 517 132 3.20 / 378.43 2 3
6 8 0.12 170 14.98 452 1151 4.35 / 379.58 2 3
Average= 4.04
(KJ/cycle)

Cycle 92 GMT 21/12/2022 11:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 29 14.92 611 264 0.26 / 371.01 2 3
2 7 2005.84 39 14.73 3238 1860 2.12 / 372.87 2 3
3 13 1394.24 17 14.80 2446 615 2.74 / 373.48 2 3
4 13 793.60 17 14.89 1615 409 3.15 / 373.89 2 5
5 13 177.32 17 15.01 753 192 3.34 / 374.08 2 3
6 8 0.00 170 14.98 452 1151 4.49 / 375.23 2 3
Average= 4.03
(KJ/cycle)

Cycle 91 GMT 11/12/2022 13:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 29 14.89 626 270 0.27 / 366.61 2 2
2 7 2004.88 40 14.72 3234 1904 2.17 / 368.51 2 3
3 13 1251.12 17 14.82 2260 569 2.74 / 369.08 2 3
4 13 703.72 17 14.90 1516 384 3.13 / 369.47 2 6
5 13 63.32 17 15.03 594 152 3.28 / 369.62 2 3
6 8 0.04 170 14.98 441 1123 4.40 / 370.74 2 4
Average= 4.03
(KJ/cycle)

Cycle 90 GMT 1/12/2022 15:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 29 14.91 615 266 0.27 / 362.24 2 2
2 7 2002.20 39 14.73 3215 1847 2.11 / 364.09 2 2
3 13 1252.32 17 14.83 2243 565 2.68 / 364.65 2 3
4 13 699.40 17 14.90 1469 372 3.05 / 365.03 2 4
5 13 55.12 17 15.02 552 141 3.19 / 365.17 2 3
6 8 0.24 170 14.97 460 1171 4.36 / 366.34 2 6
Average= 4.03
(KJ/cycle)

Cycle 89 GMT 21/11/2022 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 29 14.92 623 270 0.27 / 357.60 2 2
2 7 2008.24 40 14.74 3240 1910 2.18 / 359.51 2 3
3 13 1379.32 17 14.83 2413 608 2.79 / 360.12 2 3
4 13 791.16 17 14.90 1604 406 3.19 / 360.53 2 5
5 13 86.28 17 15.04 603 154 3.35 / 360.68 2 4
6 8 -0.16 170 15.00 443 1130 4.48 / 361.81 2 4
7 14 -0.16 25 14.96 441 165 4.64 / 361.98 2 3
Average= 4.02
(KJ/cycle)

Cycle 88 GMT 11/11/2022 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 14.91 638 276 0.28 / 353.21 2 2
2 7 2006.40 39 14.73 3215 1847 2.12 / 355.06 2 3
3 13 1390.04 17 14.81 2424 610 2.73 / 355.67 2 3
4 13 811.72 17 14.90 1610 408 3.14 / 356.08 2 4
5 13 25.60 17 15.05 486 124 3.27 / 356.20 2 4
6 8 0.20 170 14.99 444 1131 4.40 / 357.33 2 2
Average= 4.01
(KJ/cycle)

Cycle 87 GMT 1/11/2022 21:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 29 14.93 627 271 0.27 / 348.89 2 2
2 7 2004.44 39 14.73 3229 1855 2.13 / 350.75 2 2
3 13 1258.88 17 14.83 2262 570 2.70 / 351.32 2 3
4 13 706.52 17 14.91 1473 373 3.07 / 351.69 2 6
5 13 59.88 17 15.03 550 141 3.21 / 351.83 2 3
6 8 -0.40 170 14.98 433 1103 4.31 / 352.94 2 3
Average= 4.01
(KJ/cycle)

Cycle 86 GMT 22/10/2022 23:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 29 14.93 614 266 0.27 / 344.41 2 2
2 7 2007.68 39 14.75 3204 1843 2.11 / 346.25 2 3
3 13 1249.08 17 14.85 2222 561 2.67 / 346.81 2 3
4 13 820.40 17 14.89 1616 409 3.08 / 347.22 2 4
5 13 52.64 17 15.05 515 132 3.21 / 347.35 2 3
6 8 0.08 170 14.99 434 1106 4.32 / 348.46 2 3
7 14 0.08 25 14.96 439 164 4.48 / 348.62 2 3
Average= 4.01
(KJ/cycle)

Cycle 85 GMT 13/10/2022 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 29 14.94 620 269 0.27 / 340.17 2 2
2 7 2003.60 39 14.76 3205 1845 2.11 / 342.01 2 3
3 13 1258.80 17 14.86 2233 564 2.68 / 342.58 2 3
4 13 709.76 17 14.93 1461 371 3.05 / 342.95 2 4
5 13 56.28 17 15.04 524 134 3.18 / 343.08 2 2
6 8 0.20 170 15.00 416 1061 4.24 / 344.14 2 4
Average= 4.00
(KJ/cycle)

Cycle 84 GMT 3/10/2022 4: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 29 14.93 618 268 0.27 / 335.74 2 2
2 7 2009.84 40 14.76 3213 1897 2.16 / 337.64 2 3
3 13 1394.52 17 14.83 2421 610 2.77 / 338.25 2 3
4 13 807.64 17 14.90 1601 406 3.18 / 338.65 2 4
5 13 90.40 17 15.04 602 154 3.33 / 338.81 2 3
6 8 0.16 170 15.00 428 1091 4.43 / 339.90 2 3
Average= 4.00
(KJ/cycle)

Cycle 83 GMT 23/ 9/2022 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 29 14.94 623 270 0.27 / 331.50 2 2
2 7 2004.96 39 14.75 3211 1847 2.12 / 333.35 2 3
3 13 1274.68 17 14.84 2257 569 2.69 / 333.92 2 3
4 13 722.52 17 14.92 1497 380 3.07 / 334.30 2 7
5 13 28.24 17 15.05 464 119 3.18 / 334.42 2 2
6 8 0.08 170 15.01 413 1054 4.24 / 335.47 2 4
Average= 3.99
(KJ/cycle)

Cycle 82 GMT 13/ 9/2022 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 29 14.95 586 254 0.25 / 327.27 2 3
2 7 2003.00 39 14.77 3197 1842 2.10 / 329.12 2 3
3 13 1259.72 17 14.86 2223 562 2.66 / 329.68 2 3
4 13 693.36 17 14.92 1428 362 3.02 / 330.04 2 6
5 13 59.36 17 15.05 514 132 3.15 / 330.17 2 3
6 8 0.12 170 15.00 417 1063 4.21 / 331.23 2 5
Average= 3.99
(KJ/cycle)

Cycle 81 GMT 3/ 9/2022 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 29 14.98 589 256 0.26 / 323.09 2 2
2 7 2004.00 39 14.75 3216 1850 2.11 / 324.94 2 2
3 13 1262.24 17 14.84 2245 566 2.67 / 325.50 2 3
4 13 700.56 17 14.93 1449 368 3.04 / 325.87 2 4
5 13 26.84 17 15.06 466 119 3.16 / 325.99 2 3
6 8 0.16 170 15.01 404 1031 4.19 / 327.02 2 4
Average= 3.99
(KJ/cycle)

Cycle 80 GMT 24/ 8/2022 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 29 14.98 599 260 0.26 / 318.80 2 2
2 7 2009.56 39 14.77 3199 1843 2.10 / 320.64 2 2
3 13 1392.92 17 14.85 2382 601 2.70 / 321.24 2 3
4 13 802.16 17 14.92 1578 400 3.10 / 321.64 2 4
5 13 46.52 17 15.07 501 128 3.23 / 321.77 2 3
6 8 0.20 170 15.03 415 1060 4.29 / 322.83 2 4
Average= 3.99
(KJ/cycle)

Cycle 79 GMT 14/ 8/2022 14:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 14.99 558 243 0.24 / 314.54 2 3
2 7 2005.36 40 14.78 3176 1878 2.12 / 316.42 2 3
3 13 1403.32 17 14.84 2401 606 2.73 / 317.02 2 3
4 13 699.32 17 14.94 1430 363 3.09 / 317.38 2 7
5 13 57.84 17 15.08 499 128 3.22 / 317.51 2 2
6 8 0.16 170 15.02 401 1024 4.24 / 318.54 2 4
Average= 3.98
(KJ/cycle)

Cycle 78 GMT 4/ 8/2022 16:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 29 14.99 597 260 0.26 / 310.20 2 3
2 7 2005.40 40 14.77 3186 1882 2.14 / 312.08 2 3
3 13 1266.32 17 14.87 2234 565 2.71 / 312.64 2 3
4 13 713.32 17 14.94 1460 371 3.08 / 313.01 2 4
5 13 66.80 17 15.07 523 134 3.21 / 313.15 2 3
6 8 0.24 170 15.04 392 1002 4.21 / 314.15 2 2
7 14 0.24 25 15.01 390 146 4.36 / 314.30 2 3
Average= 3.98
(KJ/cycle)

Cycle 77 GMT 25/ 7/2022 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 14.99 600 261 0.26 / 306.06 2 2
2 7 2003.80 39 14.78 3183 1835 2.10 / 307.90 2 3
3 13 1393.84 17 14.85 2400 606 2.70 / 308.50 2 3
4 13 795.72 17 14.92 1564 397 3.10 / 308.90 2 5
5 8 0.08 170 15.06 405 1037 4.14 / 309.94 2 4
Average= 3.97
(KJ/cycle)

Cycle 76 GMT 15/ 7/2022 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 14.99 604 263 0.26 / 301.86 2 2
2 7 2005.32 39 14.79 3183 1836 2.10 / 303.69 2 2
3 13 1275.88 17 14.87 2239 566 2.66 / 304.26 2 3
4 13 850.20 17 14.92 1638 415 3.08 / 304.67 2 4
5 13 26.04 17 15.10 447 115 3.19 / 304.79 2 3
6 8 -0.04 170 15.04 396 1012 4.21 / 305.80 2 3
Average= 3.97
(KJ/cycle)

Cycle 75 GMT 5/ 7/2022 23:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 29 15.00 588 256 0.26 / 297.68 2 2
2 7 2006.96 39 14.79 3175 1831 2.09 / 299.51 2 3
3 13 1269.80 17 14.88 2226 563 2.65 / 300.08 2 3
4 13 709.60 17 14.96 1434 365 3.01 / 300.44 2 6
5 13 56.24 17 15.09 486 125 3.14 / 300.57 2 3
6 8 0.12 170 15.05 401 1026 4.17 / 301.59 2 4
Average= 3.97
(KJ/cycle)

Cycle 74 GMT 26/ 6/2022 1: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 29 14.98 589 256 0.26 / 293.49 2 2
2 7 2002.88 39 14.79 3175 1831 2.09 / 295.32 2 2
3 13 1382.96 17 14.87 2372 600 2.69 / 295.92 2 3
4 13 667.60 17 14.97 1384 352 3.04 / 296.28 2 4
5 8 0.24 170 15.06 392 1004 4.04 / 297.28 2 4
6 14 0.24 25 15.04 395 149 4.19 / 297.43 2 3
Average= 3.97
(KJ/cycle)

Cycle 73 GMT 16/ 6/2022 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 29 15.01 567 247 0.25 / 289.30 2 2
2 7 2002.92 39 14.79 3175 1831 2.08 / 291.13 2 2
3 13 1278.68 17 14.88 2235 565 2.64 / 291.70 2 3
4 13 711.60 17 14.95 1448 368 3.01 / 292.07 2 4
5 13 61.76 17 15.09 528 135 3.15 / 292.20 2 2
6 8 0.28 170 15.04 405 1036 4.18 / 293.24 2 3
Average= 3.96
(KJ/cycle)

Cycle 72 GMT 6/ 6/2022 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 29 14.99 573 249 0.25 / 285.09 2 3
2 7 2005.20 39 14.79 3191 1841 2.09 / 286.93 2 3
3 13 1387.88 17 14.88 2372 600 2.69 / 287.53 2 4
4 13 800.68 17 14.94 1557 395 3.09 / 287.92 2 5
5 13 92.20 17 15.08 554 142 3.23 / 288.07 2 3
6 8 -0.12 170 15.05 386 988 4.21 / 289.05 2 2
Average= 3.96
(KJ/cycle)

Cycle 71 GMT 27/ 5/2022 7:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 14.99 567 238 0.24 / 280.73 2 2
2 3 1018.52 1 15.17 1992 30 0.27 / 280.76 2 3
3 7 2005.04 39 14.80 3172 1831 2.10 / 282.59 2 2
4 13 1288.24 17 14.88 2244 568 2.67 / 283.16 2 4
5 13 858.96 17 14.94 1634 415 3.08 / 283.58 2 3
6 13 117.48 17 15.08 578 148 3.23 / 283.72 2 3
7 8 0.72 170 15.06 378 968 4.20 / 284.69 2 4
8 14 0.72 25 15.02 391 147 4.34 / 284.84 2 6
Average= 3.96
(KJ/cycle)

Cycle 70 GMT 17/ 5/2022 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 28 15.01 557 234 0.23 / 276.56 2 2
2 7 2005.72 39 14.80 3159 1823 2.06 / 278.39 2 3
3 13 1279.16 17 14.88 2226 563 2.62 / 278.95 2 2
4 13 837.80 17 14.94 1610 409 3.03 / 279.36 2 4
5 13 105.32 17 15.09 570 146 3.18 / 279.50 2 3
6 8 0.12 170 15.06 387 991 4.17 / 280.49 2 3
Average= 3.95
(KJ/cycle)

Cycle 69 GMT 7/ 5/2022 11:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 28 15.02 568 239 0.24 / 272.42 2 2
2 7 2007.76 39 14.78 3175 1830 2.07 / 274.25 2 2
3 13 1286.12 17 14.87 2247 568 2.64 / 274.82 2 2
4 13 731.16 17 14.95 1456 370 3.01 / 275.19 2 5
5 13 71.12 17 15.09 522 134 3.14 / 275.32 2 3
6 8 -0.08 170 15.06 394 1009 4.15 / 276.33 2 4
Average= 3.95
(KJ/cycle)

Cycle 68 GMT 27/ 4/2022 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 28 15.03 570 240 0.24 / 268.21 2 2
2 7 2002.12 39 14.79 3172 1830 2.07 / 270.04 2 3
3 13 1276.96 17 14.89 2230 564 2.63 / 270.60 2 3
4 13 834.40 17 14.95 1617 411 3.04 / 271.01 2 4
5 13 99.96 17 15.11 567 146 3.19 / 271.16 2 3
6 8 0.24 170 15.06 398 1019 4.21 / 272.18 2 2
Average= 3.94
(KJ/cycle)

Cycle 67 GMT 17/ 4/2022 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 28 15.02 583 245 0.25 / 263.99 2 2
2 7 2010.12 39 14.79 3170 1828 2.07 / 265.82 2 3
3 13 1394.00 17 14.88 2373 600 2.67 / 266.42 2 2
4 13 692.24 17 14.98 1414 360 3.03 / 266.78 2 5
5 13 247.32 17 15.08 777 199 3.23 / 266.98 2 3
6 8 -0.04 170 15.07 388 994 4.23 / 267.97 2 3
Average= 3.94
(KJ/cycle)

Cycle 66 GMT 7/ 4/2022 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 28 15.02 561 236 0.24 / 259.79 2 2
2 7 2008.84 39 14.80 3168 1829 2.06 / 261.62 2 2
3 13 1406.92 17 14.88 2389 604 2.67 / 262.22 2 5
4 13 805.44 17 14.97 1568 399 3.07 / 262.62 2 3
5 13 58.00 17 15.13 487 125 3.19 / 262.74 2 3
6 8 0.28 170 15.08 389 997 4.19 / 263.74 2 2
Average= 3.94
(KJ/cycle)

Cycle 65 GMT 28/ 3/2022 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 28 15.02 574 241 0.24 / 255.62 2 2
2 7 2006.92 39 14.81 3171 1832 2.07 / 257.45 2 3
3 13 1273.00 17 14.90 2225 564 2.64 / 258.01 2 3
4 13 842.32 17 14.95 1613 410 3.05 / 258.42 2 3
5 13 56.36 17 15.12 489 126 3.17 / 258.55 2 3
6 8 0.12 170 15.08 392 1005 4.18 / 259.55 2 3
Average= 3.93
(KJ/cycle)

Cycle 64 GMT 18/ 3/2022 22:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 28 15.03 561 236 0.24 / 251.41 2 2
2 7 2003.00 39 14.81 3149 1819 2.05 / 253.22 2 3
3 13 1254.12 17 14.92 2198 558 2.61 / 253.78 2 3
4 13 705.44 17 14.99 1426 363 2.98 / 254.14 2 4
5 13 54.84 17 15.14 465 120 3.10 / 254.26 2 3
6 8 0.24 170 15.08 377 966 4.06 / 255.23 2 3
7 14 0.24 25 15.05 381 143 4.21 / 255.37 2 3
Average= 3.93
(KJ/cycle)

Cycle 63 GMT 9/ 3/2022 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 28 15.05 544 229 0.23 / 247.30 2 2
2 7 2002.32 39 14.81 3162 1826 2.06 / 249.13 2 3
3 13 1261.64 17 14.91 2189 555 2.61 / 249.68 2 3
4 13 708.64 17 14.98 1420 362 2.97 / 250.04 2 3
5 13 115.88 17 15.12 584 150 3.12 / 250.19 2 3
6 8 -0.08 170 15.09 380 975 4.10 / 251.17 2 3
Average= 3.92
(KJ/cycle)

Cycle 62 GMT 27/ 2/2022 2:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 28 15.05 564 238 0.24 / 243.28 2 2
2 7 2006.72 39 14.81 3161 1826 2.06 / 245.10 2 3
3 13 1264.24 17 14.93 2201 559 2.62 / 245.66 2 3
4 13 706.08 17 15.02 1423 363 2.99 / 246.02 2 4
5 13 56.68 17 15.14 470 121 3.11 / 246.15 2 2
6 8 0.16 170 15.10 361 927 4.03 / 247.07 2 2
Average= 3.92
(KJ/cycle)

Cycle 61 GMT 17/ 2/2022 4:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 15.05 553 233 0.23 / 239.15 2 2
2 7 2005.16 39 14.81 3163 1827 2.06 / 240.97 2 4
3 13 1392.84 17 14.89 2367 599 2.66 / 241.57 2 2
4 13 796.24 17 14.98 1553 395 3.05 / 241.97 2 3
5 13 55.04 17 15.15 467 120 3.17 / 242.09 2 2
6 8 0.00 170 15.11 370 950 4.13 / 243.04 2 3
Average= 3.92
(KJ/cycle)

Cycle 60 GMT 7/ 2/2022 6:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 28 15.06 547 231 0.23 / 234.88 2 2
2 7 2003.52 39 14.83 3149 1821 2.05 / 236.71 2 3
3 13 1387.32 17 14.90 2352 596 2.65 / 237.30 2 3
4 13 705.12 17 15.01 1410 360 3.01 / 237.66 2 3
5 13 125.68 17 15.13 589 151 3.16 / 237.81 2 3
6 8 -0.12 170 15.12 374 961 4.12 / 238.77 2 2
7 14 -0.12 25 15.08 372 140 4.26 / 238.91 2 6
Average= 3.92
(KJ/cycle)

Cycle 59 GMT 28/ 1/2022 9: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 28 15.07 546 230 0.23 / 230.86 2 2
2 7 2004.68 39 14.81 3137 1812 2.04 / 232.67 2 3
3 13 1248.68 17 14.92 2165 549 2.59 / 233.22 2 4
4 13 708.00 17 15.01 1425 364 2.96 / 233.58 2 5
5 13 61.60 17 15.15 495 127 3.08 / 233.71 2 2
6 8 0.20 170 15.12 366 941 4.02 / 234.65 2 4
Average= 3.91
(KJ/cycle)

Cycle 58 GMT 18/ 1/2022 11: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 15.07 524 221 0.22 / 226.82 2 2
2 7 2001.76 39 14.82 3139 1814 2.04 / 228.63 2 3
3 13 1372.12 17 14.91 2318 588 2.62 / 229.22 2 3
4 13 656.60 17 15.04 1323 338 2.96 / 229.56 2 4
5 13 101.76 17 15.15 533 137 3.10 / 229.70 2 2
6 8 -0.08 170 15.12 363 933 4.03 / 230.63 2 3
Average= 3.91
(KJ/cycle)

Cycle 57 GMT 8/ 1/2022 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 28 15.09 543 229 0.23 / 222.69 2 2
2 7 2004.20 39 14.82 3143 1817 2.05 / 224.51 2 3
3 13 1267.88 17 14.93 2174 552 2.60 / 225.06 2 3
4 13 711.96 17 15.02 1417 362 2.96 / 225.42 2 4
5 13 33.04 17 15.17 416 107 3.07 / 225.53 2 2
6 8 0.12 170 15.13 363 934 4.00 / 226.46 2 3
7 14 0.12 25 15.10 354 134 4.13 / 226.60 2 3
Average= 3.91
(KJ/cycle)

Cycle 56 GMT 29/12/2021 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 28 15.10 536 227 0.23 / 218.71 2 2
2 7 2002.16 39 14.83 3147 1820 2.05 / 220.53 2 3
3 13 1258.76 17 14.94 2175 552 2.60 / 221.09 2 4
4 13 708.96 17 15.03 1413 361 2.96 / 221.45 2 5
5 13 55.92 17 15.17 454 117 3.08 / 221.56 2 3
6 8 0.04 170 15.14 350 901 3.98 / 222.46 2 3
Average= 3.90
(KJ/cycle)

Cycle 55 GMT 19/12/2021 16:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 28 15.10 550 233 0.23 / 214.59 2 2
2 7 2002.16 39 14.84 3143 1819 2.05 / 216.41 2 3
3 13 1251.44 17 14.95 2163 550 2.60 / 216.96 2 3
4 13 692.60 17 15.05 1386 355 2.96 / 217.31 2 3
5 13 29.56 17 15.19 401 104 3.06 / 217.42 2 2
6 8 0.08 170 15.15 362 932 3.99 / 218.35 2 4
7 14 0.08 25 15.12 365 138 4.13 / 218.49 2 4
Average= 3.90
(KJ/cycle)

Cycle 54 GMT 9/12/2021 18:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 15.11 551 233 0.23 / 210.58 2 2
2 7 2004.52 39 14.84 3151 1824 2.06 / 212.41 2 2
3 13 1242.96 17 14.97 2169 552 2.61 / 212.96 2 3
4 13 693.96 17 15.04 1392 356 2.96 / 213.31 2 4
5 13 50.40 17 15.20 455 118 3.08 / 213.43 2 2
6 8 0.00 170 15.15 359 925 4.01 / 214.36 2 3
Average= 3.90
(KJ/cycle)

Cycle 53 GMT 29/11/2021 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 28 15.11 547 231 0.23 / 206.50 2 2
2 7 2004.36 39 14.85 3164 1832 2.06 / 208.34 2 3
3 13 1272.08 17 14.94 2212 562 2.63 / 208.90 2 3
4 13 714.60 17 15.05 1438 368 2.99 / 209.27 2 5
5 13 55.60 17 15.19 473 122 3.12 / 209.39 2 2
6 8 0.20 170 15.15 373 961 4.08 / 210.35 2 3
Average= 3.90
(KJ/cycle)

Cycle 52 GMT 19/11/2021 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 28 15.10 558 236 0.24 / 202.50 2 2
2 7 2001.84 39 14.85 3145 1821 2.06 / 204.32 2 2
3 13 1249.36 17 14.95 2149 546 2.60 / 204.86 2 3
4 13 690.32 17 15.06 1394 357 2.96 / 205.22 2 3
5 13 29.68 17 15.21 414 107 3.07 / 205.33 2 2
6 8 -0.04 170 15.16 367 946 4.01 / 206.27 2 4
Average= 3.89
(KJ/cycle)

Cycle 51 GMT 10/11/2021 1:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 28 15.11 552 234 0.23 / 198.39 2 2
2 7 2001.96 39 14.85 3142 1820 2.05 / 200.21 2 3
3 13 1377.44 17 14.94 2335 593 2.65 / 200.80 2 3
4 13 792.92 17 15.04 1524 390 3.04 / 201.19 2 4
5 13 44.00 17 15.20 424 110 3.15 / 201.30 2 2
6 8 -0.04 170 15.15 371 956 4.10 / 202.26 2 3
Average= 3.89
(KJ/cycle)

Cycle 50 GMT 31/10/2021 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 28 15.12 544 230 0.23 / 194.35 2 2
2 7 2006.16 39 14.84 3146 1821 2.05 / 196.17 2 3
3 13 1378.32 17 14.92 2340 594 2.64 / 196.76 2 2
4 13 652.32 17 15.08 1342 344 2.99 / 197.11 2 6
5 13 49.20 17 15.21 444 115 3.10 / 197.22 2 3
6 8 -0.16 170 15.16 363 936 4.04 / 198.16 2 4
Average= 3.89
(KJ/cycle)

Cycle 49 GMT 21/10/2021 5:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 28 15.11 552 234 0.23 / 190.12 2 2
2 7 2002.64 39 14.85 3164 1832 2.07 / 191.95 2 3
3 13 1245.76 17 14.96 2155 548 2.61 / 192.50 2 2
4 13 819.48 17 15.04 1569 401 3.02 / 192.90 2 3
5 13 91.92 17 15.19 534 138 3.15 / 193.04 2 3
6 8 0.20 170 15.16 366 943 4.10 / 193.98 2 3
7 14 0.20 25 15.14 368 139 4.24 / 194.12 2 3
Average= 3.88
(KJ/cycle)

Cycle 48 GMT 11/10/2021 7:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 28 15.13 540 229 0.23 / 186.04 2 2
2 7 2003.84 39 14.84 3137 1816 2.04 / 187.86 2 3
3 13 1247.00 17 14.97 2171 552 2.60 / 188.41 2 3
4 13 818.48 17 15.02 1568 400 3.00 / 188.81 2 4
5 13 47.16 17 15.21 457 118 3.12 / 188.93 2 2
6 8 0.04 170 15.16 371 956 4.07 / 189.88 2 3
Average= 3.88
(KJ/cycle)

Cycle 47 GMT 1/10/2021 9:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 15.13 545 231 0.23 / 181.79 2 2
2 7 2002.44 40 14.85 3137 1863 2.09 / 183.66 2 3
3 13 1256.32 17 14.98 2169 552 2.65 / 184.21 2 2
4 13 807.16 17 15.04 1545 395 3.04 / 184.60 2 4
5 13 92.84 17 15.21 515 133 3.17 / 184.74 2 3
6 8 0.08 170 15.17 363 936 4.11 / 185.67 2 4
7 14 0.08 25 15.15 369 140 4.25 / 185.81 2 3
Average= 3.87
(KJ/cycle)

Cycle 46 GMT 21/ 9/2021 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 28 15.15 542 230 0.23 / 177.82 2 2
2 7 2001.72 39 14.86 3132 1815 2.05 / 179.63 2 3
3 13 1259.16 17 14.97 2165 551 2.60 / 180.18 2 4
4 13 695.72 17 15.09 1383 355 2.95 / 180.54 2 3
5 13 30.80 17 15.23 404 105 3.06 / 180.64 2 2
6 8 0.00 170 15.18 357 921 3.98 / 181.56 2 4
Average= 3.86
(KJ/cycle)

Cycle 45 GMT 11/ 9/2021 13:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 28 15.13 562 238 0.24 / 173.74 2 2
2 7 2003.44 39 14.86 3145 1823 2.06 / 175.56 2 3
3 13 1238.20 17 14.98 2162 551 2.61 / 176.11 2 5
4 13 799.28 17 15.05 1550 397 3.01 / 176.51 2 3
5 8 -0.20 170 15.19 364 940 3.95 / 177.45 2 3
6 14 -0.20 25 15.16 360 136 4.08 / 177.59 2 4
Average= 3.86
(KJ/cycle)

Cycle 44 GMT 1/ 9/2021 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 28 15.14 540 229 0.23 / 169.64 2 2
2 7 2002.20 39 14.87 3142 1822 2.05 / 171.47 2 3
3 13 1374.04 17 14.96 2332 593 2.64 / 172.06 2 2
4 13 776.64 17 15.07 1505 386 3.03 / 172.44 2 4
5 13 36.68 17 15.25 420 109 3.14 / 172.55 2 2
6 8 0.20 170 15.20 367 948 4.09 / 173.50 2 3
Average= 3.86
(KJ/cycle)

Cycle 43 GMT 22/ 8/2021 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 15.14 530 225 0.22 / 165.68 2 2
2 7 2004.96 39 14.85 3132 1814 2.04 / 167.49 2 3
3 13 1241.72 17 14.98 2149 547 2.59 / 168.04 2 4
4 13 671.64 17 15.09 1358 348 2.93 / 168.39 2 3
5 13 24.76 17 15.23 390 101 3.04 / 168.49 2 2
6 8 -0.08 170 15.19 359 927 3.96 / 169.41 2 4
Average= 3.85
(KJ/cycle)

Cycle 42 GMT 12/ 8/2021 20: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 28 15.15 537 228 0.23 / 161.68 2 2
2 7 2003.24 39 14.85 3129 1812 2.04 / 163.50 2 4
3 13 1256.44 17 14.98 2170 553 2.59 / 164.05 2 4
4 13 694.76 17 15.09 1382 355 2.95 / 164.40 2 4
5 8 0.12 170 15.20 353 912 3.86 / 165.32 2 2
6 14 0.12 25 15.17 358 136 4.00 / 165.45 2 4
Average= 3.85
(KJ/cycle)

Cycle 41 GMT 2/ 8/2021 22: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 27 15.16 538 220 0.22 / 157.64 2 2
2 3 1020.00 1 15.26 1908 29 0.25 / 157.67 2 3
3 7 2003.48 39 14.86 3133 1816 2.07 / 159.49 2 3
4 13 1251.16 17 14.99 2157 550 2.61 / 160.03 2 4
5 13 813.88 17 15.05 1552 397 3.01 / 160.43 2 3
6 13 28.24 17 15.24 397 103 3.11 / 160.53 2 2
7 8 0.24 170 15.19 357 922 4.04 / 161.46 2 3
Average= 3.84
(KJ/cycle)

Cycle 40 GMT 24/ 7/2021 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 27 15.16 538 220 0.22 / 153.75 2 2
2 7 2007.48 39 14.86 3132 1815 2.04 / 155.56 2 2
3 13 1244.76 17 15.00 2130 543 2.58 / 156.10 2 3
4 13 816.04 17 15.07 1549 397 2.98 / 156.50 2 3
5 8 0.12 170 15.22 355 919 3.89 / 157.42 2 4
Average= 3.84
(KJ/cycle)

Cycle 39 GMT 14/ 7/2021 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 27 15.16 546 223 0.22 / 149.76 2 2
2 3 1023.88 1 15.26 1913 29 0.25 / 149.79 2 2
3 7 2004.96 39 14.86 3132 1815 2.07 / 151.61 2 3
4 13 1237.76 17 14.98 2122 540 2.61 / 152.15 2 3
5 13 688.04 17 15.11 1375 353 2.96 / 152.50 2 3
6 13 25.40 17 15.25 391 101 3.06 / 152.60 2 2
7 8 -0.04 170 15.21 357 923 3.99 / 153.53 2 3
Average= 3.84
(KJ/cycle)

Cycle 38 GMT 4/ 7/2021 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 27 15.16 544 223 0.22 / 145.78 2 2
2 7 2005.52 39 14.86 3133 1816 2.04 / 147.60 2 3
3 13 1134.72 17 15.01 1990 508 2.55 / 148.10 2 3
4 13 727.32 17 15.09 1434 368 2.91 / 148.47 2 4
5 13 127.40 17 15.23 573 148 3.06 / 148.62 2 2
6 8 0.08 170 15.20 356 920 3.98 / 149.54 2 3
Average= 3.83
(KJ/cycle)

Cycle 37 GMT 24/ 6/2021 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 27 15.17 546 224 0.22 / 141.72 2 2
2 7 2002.92 40 14.87 3128 1861 2.08 / 143.58 2 3
3 13 1251.32 17 15.00 2138 545 2.63 / 144.13 2 4
4 13 818.80 17 15.08 1551 398 3.03 / 144.52 2 3
5 13 87.40 17 15.24 490 127 3.15 / 144.65 2 3
6 8 -0.12 170 15.21 351 908 4.06 / 145.56 2 2
Average= 3.83
(KJ/cycle)

Cycle 36 GMT 14/ 6/2021 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 27 15.16 541 221 0.22 / 137.79 2 2
2 7 2005.40 39 14.87 3135 1818 2.04 / 139.61 2 3
3 13 1231.24 17 15.02 2128 543 2.58 / 140.15 2 3
4 13 551.60 17 15.15 1189 306 2.89 / 140.46 2 4
5 13 57.84 17 15.25 451 117 3.01 / 140.57 2 2
6 8 0.04 170 15.22 357 924 3.93 / 141.50 2 3
Average= 3.82
(KJ/cycle)

Cycle 35 GMT 4/ 6/2021 10: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 27 15.19 532 218 0.22 / 133.57 2 2
2 7 2002.48 39 14.88 3139 1822 2.04 / 135.40 2 2
3 13 1395.60 17 14.98 2347 598 2.64 / 135.99 2 3
4 13 792.28 17 15.10 1519 390 3.03 / 136.38 2 3
5 13 114.04 17 15.23 533 138 3.17 / 136.52 2 2
6 8 0.12 170 15.22 352 911 4.08 / 137.43 2 4
7 14 0.12 25 15.20 355 135 4.21 / 137.57 2 3
Average= 3.82
(KJ/cycle)

Cycle 34 GMT 25/ 5/2021 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 27 15.17 524 215 0.21 / 129.74 2 2
2 7 2003.72 39 14.88 3130 1816 2.03 / 131.56 2 3
3 13 1131.52 17 15.03 1989 508 2.54 / 132.07 2 4
4 13 722.96 17 15.11 1433 368 2.91 / 132.43 2 4
5 8 0.24 170 15.23 356 922 3.83 / 133.36 2 2
Average= 3.81
(KJ/cycle)

Cycle 33 GMT 15/ 5/2021 13:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 26 15.17 544 215 0.21 / 125.77 2 2
2 7 2001.60 39 14.89 3134 1820 2.03 / 127.59 2 3
3 13 1225.88 17 15.04 2116 541 2.58 / 128.13 2 3
4 13 657.64 17 15.14 1333 343 2.92 / 128.47 2 3
5 13 106.96 17 15.24 515 133 3.05 / 128.60 2 3
6 8 -0.12 170 15.22 357 924 3.98 / 129.53 2 4
Average= 3.81
(KJ/cycle)

Cycle 32 GMT 5/ 5/2021 15:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 26 15.19 541 214 0.21 / 121.76 2 2
2 7 2014.40 39 14.88 3144 1825 2.04 / 123.59 2 3
3 13 1385.48 17 14.98 2319 591 2.63 / 124.18 2 3
4 13 656.32 17 15.14 1331 343 2.97 / 124.52 2 5
5 13 43.68 17 15.27 412 107 3.08 / 124.63 2 2
6 8 0.12 170 15.23 356 922 4.00 / 125.55 2 3
Average= 3.80
(KJ/cycle)

Cycle 31 GMT 25/ 4/2021 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 27 15.19 547 224 0.22 / 117.69 2 2
2 7 2002.84 39 14.89 3128 1816 2.04 / 119.50 2 3
3 13 1222.24 17 15.04 2101 537 2.58 / 120.04 2 3
4 13 661.92 17 15.15 1340 345 2.92 / 120.38 2 4
5 13 105.60 17 15.26 516 134 3.06 / 120.52 2 3
6 8 0.16 170 15.23 347 898 3.96 / 121.42 2 3
7 14 0.16 25 15.21 355 135 4.09 / 121.55 3 4
Average= 3.80
(KJ/cycle)

Cycle 30 GMT 15/ 4/2021 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 27 15.19 531 218 0.22 / 113.65 2 2
2 7 2005.20 39 14.89 3120 1812 2.03 / 115.46 2 3
3 13 1387.88 17 14.99 2314 590 2.62 / 116.05 2 3
4 13 754.20 17 15.13 1458 375 2.99 / 116.43 2 3
5 13 70.52 17 15.27 464 120 3.11 / 116.55 2 3
6 8 -0.04 170 15.24 353 915 4.03 / 117.46 2 3
Average= 3.79
(KJ/cycle)

Cycle 29 GMT 5/ 4/2021 21:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.84 27 15.19 546 224 0.22 / 109.69 2 2
2 7 2006.76 40 14.90 3124 1862 2.09 / 111.55 2 3
3 13 1139.40 17 15.06 1989 509 2.60 / 112.06 2 3
4 13 722.40 17 15.13 1420 365 2.96 / 112.42 2 3
5 13 30.44 17 15.29 389 101 3.06 / 112.52 2 2
6 8 0.16 170 15.23 351 909 3.97 / 113.43 2 5
Average= 3.78
(KJ/cycle)

Cycle 28 GMT 26/ 3/2021 23:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 26 15.20 517 204 0.20 / 105.79 2 2
2 7 2003.04 39 14.90 3102 1803 2.01 / 107.59 2 3
3 13 1234.28 17 15.04 2095 536 2.54 / 108.13 2 3
4 13 547.40 17 15.18 1165 301 2.84 / 108.43 2 4
5 13 122.20 17 15.27 538 140 2.98 / 108.57 2 3
6 8 -0.24 170 15.24 345 894 3.88 / 109.46 2 3
Average= 3.77
(KJ/cycle)

Cycle 27 GMT 17/ 3/2021 1:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 26 15.19 526 208 0.21 / 101.91 2 2
2 7 2004.20 39 14.90 3106 1805 2.01 / 103.72 2 3
3 13 1237.56 17 15.04 2104 538 2.55 / 104.25 2 3
4 13 660.04 17 15.15 1330 343 2.89 / 104.60 2 3
5 13 49.84 17 15.29 417 108 3.00 / 104.71 2 2
6 8 0.24 170 15.25 339 879 3.88 / 105.58 2 3
Average= 3.77
(KJ/cycle)

Cycle 26 GMT 7/ 3/2021 3:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 26 15.20 506 200 0.20 / 98.06 2 2
2 7 2002.28 39 14.90 3118 1812 2.01 / 99.87 2 2
3 13 1140.40 17 15.06 1988 509 2.52 / 100.38 2 3
4 13 694.40 17 15.14 1377 354 2.88 / 100.73 2 3
5 13 52.16 17 15.28 417 108 2.98 / 100.84 2 2
6 8 -0.08 170 15.24 334 865 3.85 / 101.70 2 3
Average= 3.77
(KJ/cycle)

Cycle 25 GMT 25/ 2/2021 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 26 15.19 534 211 0.21 / 93.94 2 2
2 7 2004.80 39 14.91 3127 1818 2.03 / 95.76 2 3
3 13 1378.48 17 15.03 2314 591 2.62 / 96.35 2 3
4 13 654.32 17 15.17 1329 343 2.96 / 96.69 2 3
5 13 98.32 17 15.28 511 133 3.10 / 96.82 2 3
6 8 -0.08 170 15.25 347 900 4.00 / 97.72 2 3
7 14 -0.08 25 15.23 348 133 4.13 / 97.86 2 3
Average= 3.76
(KJ/cycle)

Cycle 24 GMT 15/ 2/2021 6:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 26 15.20 517 204 0.20 / 89.94 2 2
2 3 1017.96 1 15.33 1889 29 0.23 / 89.97 2 2
3 7 2003.92 39 14.89 3112 1807 2.04 / 91.77 2 3
4 13 1130.36 17 15.08 1969 505 2.55 / 92.28 2 3
5 13 574.32 17 15.19 1204 311 2.86 / 92.59 2 3
6 13 61.48 17 15.29 435 113 2.97 / 92.70 2 2
7 8 0.08 170 15.26 344 892 3.86 / 93.60 2 3
8 14 0.08 25 15.23 345 131 3.99 / 93.73 2 3
Average= 3.75
(KJ/cycle)

Cycle 23 GMT 5/ 2/2021 8:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 26 15.22 526 208 0.21 / 86.06 2 2
2 7 2003.96 39 14.92 3096 1802 2.01 / 87.86 2 3
3 13 1249.48 17 15.06 2110 540 2.55 / 88.40 2 4
4 13 658.28 17 15.17 1316 339 2.89 / 88.74 2 4
5 13 94.24 17 15.29 488 127 3.02 / 88.87 2 3
6 8 0.16 170 15.26 335 869 3.89 / 89.73 2 3
Average= 3.74
(KJ/cycle)

Cycle 22 GMT 26/ 1/2021 10:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 26 15.23 490 194 0.19 / 82.21 2 2
2 7 2001.44 39 14.92 3088 1797 1.99 / 84.00 2 3
3 13 1227.96 17 15.07 2078 532 2.52 / 84.54 2 3
4 13 660.40 17 15.18 1306 337 2.86 / 84.87 2 3
5 13 51.04 17 15.30 412 107 2.97 / 84.98 2 2
6 8 0.08 170 15.26 335 869 3.84 / 85.85 2 3
Average= 3.73
(KJ/cycle)

Cycle 21 GMT 16/ 1/2021 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 26 15.23 508 201 0.20 / 78.26 2 2
2 7 2003.72 39 14.92 3102 1805 2.01 / 80.06 2 2
3 13 1235.12 17 15.07 2106 540 2.55 / 80.60 2 3
4 13 655.48 17 15.19 1314 339 2.88 / 80.94 2 3
5 13 45.00 17 15.30 394 102 2.99 / 81.05 2 2
6 8 -0.12 170 15.26 325 843 3.83 / 81.89 2 3
7 14 -0.12 25 15.24 325 124 3.95 / 82.01 2 3
Average= 3.73
(KJ/cycle)

Cycle 20 GMT 6/ 1/2021 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 26 15.23 502 199 0.20 / 74.43 2 2
2 7 2005.00 39 14.92 3111 1810 2.01 / 76.24 2 3
3 13 1233.08 17 15.07 2103 539 2.55 / 76.78 2 2
4 13 657.72 17 15.18 1312 339 2.89 / 77.12 2 3
5 13 47.72 17 15.31 397 103 2.99 / 77.22 2 2
6 8 0.16 170 15.27 323 838 3.83 / 78.06 2 3
Average= 3.72
(KJ/cycle)

Cycle 19 GMT 27/12/2020 16: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 26 15.22 505 200 0.20 / 70.61 2 2
2 7 2003.68 39 14.93 3093 1801 2.00 / 72.41 2 3
3 13 1233.40 17 15.07 2103 539 2.54 / 72.95 2 3
4 13 647.84 17 15.19 1296 335 2.87 / 73.28 2 3
5 13 45.48 17 15.31 395 103 2.98 / 73.39 2 2
6 8 0.24 170 15.28 325 844 3.82 / 74.23 2 5
Average= 3.71
(KJ/cycle)

Cycle 18 GMT 17/12/2020 17:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 26 15.24 510 202 0.20 / 66.78 2 2
2 7 2004.04 30 15.01 3101 1396 1.60 / 68.17 2 3
3 13 1432.76 22 15.04 2360 781 2.38 / 68.95 2 3
4 13 709.72 22 15.17 1384 462 2.84 / 69.42 2 3
5 13 45.20 22 15.31 393 132 2.97 / 69.55 2 2
6 8 0.00 170 15.28 331 860 3.83 / 70.41 2 3
Average= 3.71
(KJ/cycle)

Cycle 17 GMT 7/12/2020 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 26 15.23 509 202 0.20 / 62.94 2 2
2 7 2003.48 30 15.00 3103 1396 1.60 / 64.33 2 2
3 13 1444.92 22 15.03 2371 784 2.38 / 65.12 2 3
4 13 716.60 22 15.18 1389 464 2.85 / 65.58 2 3
5 13 54.92 22 15.31 411 138 2.98 / 65.72 2 2
6 8 0.12 170 15.28 330 857 3.84 / 66.58 2 3
Average= 3.70
(KJ/cycle)

Cycle 16 GMT 27/11/2020 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 26 15.24 494 196 0.20 / 59.02 2 2
2 3 1019.88 1 15.32 1888 29 0.22 / 59.05 2 2
3 7 2004.16 30 15.01 3109 1400 1.62 / 60.45 2 3
4 13 1565.00 22 15.00 2550 841 2.47 / 61.29 2 2
5 13 679.52 22 15.17 1346 449 2.92 / 61.74 2 3
6 13 44.32 22 15.32 402 135 3.05 / 61.87 2 2
7 8 -0.20 170 15.28 331 860 3.91 / 62.73 2 4
Average= 3.69
(KJ/cycle)

Cycle 15 GMT 17/11/2020 23:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 26 15.26 502 199 0.20 / 55.19 2 2
2 7 2005.32 31 15.01 3108 1446 1.65 / 56.63 2 3
3 13 1448.20 22 15.04 2391 791 2.44 / 57.42 2 3
4 13 713.24 22 15.19 1384 463 2.90 / 57.89 2 3
5 13 22.60 22 15.33 347 117 3.02 / 58.00 2 2
6 8 0.08 170 15.29 316 821 3.84 / 58.82 2 4
Average= 3.68
(KJ/cycle)

Cycle 14 GMT 8/11/2020 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 26 15.25 514 204 0.20 / 51.41 2 2
2 7 2017.68 31 15.01 3135 1459 1.66 / 52.87 2 3
3 13 1494.60 22 15.04 2443 808 2.47 / 53.68 2 4
4 13 739.36 22 15.18 1420 474 2.95 / 54.15 2 3
5 8 0.24 170 15.31 321 835 3.78 / 54.99 2 3
Average= 3.67
(KJ/cycle)

Cycle 13 GMT 29/10/2020 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 26 15.27 512 203 0.20 / 47.70 2 2
2 7 2003.80 30 15.02 3091 1393 1.60 / 49.09 2 3
3 13 1580.76 22 15.02 2555 844 2.44 / 49.94 2 3
4 13 673.40 22 15.20 1328 444 2.88 / 50.38 2 3
5 8 0.08 165 15.31 326 824 3.71 / 51.21 2 3
Average= 3.66
(KJ/cycle)

Cycle 12 GMT 19/10/2020 4:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 26 15.26 503 200 0.20 / 43.98 2 2
2 7 2007.36 30 15.02 3100 1397 1.60 / 45.37 2 3
3 13 1588.20 22 15.02 2569 849 2.45 / 46.22 2 3
4 13 707.96 22 15.18 1379 461 2.91 / 46.68 2 4
5 8 0.16 165 15.31 322 813 3.72 / 47.50 2 3
Average= 3.65
(KJ/cycle)

Cycle 11 GMT 9/10/2020 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 26 15.27 509 202 0.20 / 40.08 2 2
2 7 2002.44 30 15.01 3103 1397 1.60 / 41.47 2 2
3 13 1567.16 22 15.03 2546 842 2.44 / 42.31 2 2
4 13 812.88 22 15.16 1519 507 2.95 / 42.82 2 3
5 8 0.64 165 15.31 320 808 3.76 / 43.63 2 2
6 14 0.64 30 15.29 324 149 3.90 / 43.78 2 3
Average= 3.65
(KJ/cycle)

Cycle 10 GMT 29/ 9/2020 7:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 26 15.26 509 202 0.20 / 36.32 2 2
2 7 2002.20 30 15.03 3109 1402 1.60 / 37.72 2 2
3 13 1579.96 22 15.03 2557 845 2.45 / 38.57 2 2
4 13 809.72 22 15.17 1513 505 2.95 / 39.07 2 2
5 8 0.08 165 15.32 316 799 3.75 / 39.87 2 3
Average= 3.62
(KJ/cycle)

Cycle 9 GMT 19/ 9/2020 9:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 26 15.28 497 197 0.20 / 32.36 2 2
2 7 2002.68 38 14.97 3094 1760 1.96 / 34.12 2 2
3 13 1269.28 18 15.12 2139 582 2.54 / 34.70 2 2
4 13 678.16 18 15.22 1339 367 2.91 / 35.07 2 2
5 13 18.28 18 15.35 343 95 3.00 / 35.17 2 2
6 8 -0.04 165 15.32 319 806 3.81 / 35.97 2 4
7 14 -0.04 30 15.30 322 148 3.96 / 36.12 2 2
Average= 3.61
(KJ/cycle)

Cycle 8 GMT 9/ 9/2020 10:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 25 15.28 501 191 0.19 / 28.68 2 2
2 3 1019.84 1 15.35 1869 29 0.22 / 28.70 2 2
3 7 2002.88 38 14.97 3080 1752 1.97 / 30.46 2 2
4 13 1237.32 18 15.11 2093 569 2.54 / 31.03 2 2
5 13 661.20 18 15.22 1307 358 2.90 / 31.38 2 2
6 8 0.28 165 15.32 309 781 3.68 / 32.17 2 2
Average= 3.57
(KJ/cycle)

Cycle 7 GMT 30/ 8/2020 12:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 25 15.28 495 189 0.19 / 24.98 2 2
2 7 2003.40 39 14.98 3080 1799 1.99 / 26.78 2 2
3 13 1252.72 18 15.12 2099 571 2.56 / 27.35 2 2
4 13 673.68 18 15.23 1326 364 2.92 / 27.71 2 2
5 8 0.20 165 15.33 306 774 3.70 / 28.48 2 2
Average= 3.56
(KJ/cycle)

Cycle 6 GMT 20/ 8/2020 13:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 23 15.28 480 169 0.17 / 20.37 2 2
2 10 1027.76 2 15.27 1880 57 0.23 / 20.43 2 2
3 7 2002.24 75 14.84 3079 3427 3.65 / 23.85 2 2
4 13 120.04 18 15.34 521 144 3.80 / 24.00 2 3
5 8 -0.08 165 15.32 312 789 4.59 / 24.79 2 3
Average= 3.54
(KJ/cycle)

Cycle 5 GMT 10/ 8/2020 15:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 26 15.30 494 197 0.20 / 15.87 2 2
2 3 923.60 -1 15.66 1 0 0.00 / 15.87 2 2
3 3 950.24 -1 15.68 1 0 0.00 / 15.87 2 2
4 7 2001.44 75 14.84 3058 3404 3.60 / 19.27 2 2
5 13 142.16 18 15.34 536 148 3.75 / 19.42 2 3
6 8 0.00 165 15.32 309 781 4.53 / 20.20 2 2
Average= 3.37
(KJ/cycle)

Cycle 4 GMT 31/ 7/2020 17:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 24 15.30 485 178 0.18 / 12.16 2 2
2 7 1517.20 75 15.02 2427 2734 2.91 / 14.89 2 2
3 8 0.04 165 15.34 309 782 3.69 / 15.67 2 3
Average= 3.13
(KJ/cycle)

Cycle 3 GMT 30/ 7/2020 18: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 22 15.29 484 163 0.16 / 8.48 2 2
2 10 1008.64 2 15.29 1828 56 0.22 / 8.54 2 2
3 7 1513.52 74 15.03 2427 2699 2.92 / 11.24 2 2
4 8 0.16 165 15.35 292 740 3.66 / 11.98 2 3
Average= 2.99
(KJ/cycle)

Cycle 2 GMT 29/ 7/2020 18:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 15.32 477 205 0.20 / 4.76 2 2
2 3 855.60 -3 15.68 1 0 0.00 / 4.76 2 2
3 3 957.36 -1 15.68 0 0 0.00 / 4.76 2 2
4 7 1517.00 74 15.02 2420 2690 2.89 / 7.45 2 2
5 13 91.60 18 15.36 448 124 3.02 / 7.57 2 2
6 8 0.16 165 15.33 297 751 3.77 / 8.32 2 2
Average= 2.77
(KJ/cycle)

Cycle 1 GMT 28/ 7/2020 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 24 15.46 438 163 0.16 / 1.87 2 2
2 3 969.72 -1 15.66 1 0 0.00 / 1.87 2 2
3 3 1032.04 1 15.36 1879 29 0.19 / 1.90 2 2
4 7 973.72 74 15.18 1697 1906 2.10 / 3.80 2 3
5 8 0.08 165 15.37 295 748 2.85 / 4.55 2 2
Average= 2.28
(KJ/cycle)

Cycle 0 GMT 28/ 7/2020 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 125.24 24 15.59 464 174 0.17 / 0.17 2 2
2 7 137.40 74 15.56 473 545 0.72 / 0.72 2 2
3 8 0.12 240 15.52 265 987 1.71 / 1.71 2 11
Average= 1.71