SIO Argo Site:
Pump Diagnostics Page   



Serial= 8847 WMO= 5906130

Return

←PreviousNext→

Cycle 185 GMT 14/12/2024 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 31 14.71 445 203 0.20 / 720.65 2 3
2 7 2012.16 53 14.61 3060 2369 2.57 / 723.02 2 2
3 13 1046.20 20 14.55 1775 517 3.09 / 723.53 2 3
4 13 323.64 20 14.71 760 224 3.31 / 723.76 2 3
5 8 -0.16 165 14.77 251 612 3.92 / 724.37 2 2
Average= 3.89
(KJ/cycle)

Cycle 184 GMT 4/12/2024 8:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 30 14.73 444 196 0.20 / 716.69 2 3
2 7 2007.20 53 14.62 3055 2367 2.56 / 719.06 2 2
3 13 1025.00 20 14.56 1751 510 3.07 / 719.57 2 4
4 13 421.76 20 14.68 902 265 3.34 / 719.83 2 3
5 8 0.20 165 14.76 250 609 3.95 / 720.44 2 2
Average= 3.89
(KJ/cycle)

Cycle 183 GMT 24/11/2024 13:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 30 14.75 437 193 0.19 / 712.79 2 3
2 7 2004.40 52 14.61 3037 2307 2.50 / 715.10 2 2
3 13 1036.08 20 14.57 1763 514 3.01 / 715.61 2 3
4 13 424.80 20 14.69 907 266 3.28 / 715.88 2 3
5 8 -0.24 165 14.76 254 619 3.90 / 716.50 2 3
Average= 3.89
(KJ/cycle)

Cycle 182 GMT 14/11/2024 19: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 30 14.75 424 188 0.19 / 708.92 2 3
2 7 2005.68 53 14.63 3039 2356 2.54 / 711.28 2 2
3 13 1035.00 20 14.58 1761 514 3.06 / 711.79 2 3
4 13 317.12 20 14.72 739 218 3.28 / 712.01 2 3
5 8 0.04 165 14.79 241 588 3.86 / 712.60 2 3
Average= 3.89
(KJ/cycle)

Cycle 181 GMT 5/11/2024 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 31 14.74 450 206 0.21 / 705.03 2 3
2 7 2008.84 52 14.63 3048 2319 2.52 / 707.35 2 2
3 13 1052.20 20 14.56 1785 520 3.04 / 707.87 2 3
4 13 453.76 20 14.69 945 278 3.32 / 708.14 2 3
5 8 0.12 165 14.78 242 590 3.91 / 708.73 2 2
Average= 3.89
(KJ/cycle)

Cycle 180 GMT 26/10/2024 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 31 14.73 457 209 0.21 / 701.02 2 3
2 7 2010.52 53 14.62 3049 2363 2.57 / 703.39 2 2
3 13 1045.00 20 14.56 1774 517 3.09 / 703.90 2 3
4 13 512.00 20 14.66 1024 300 3.39 / 704.20 2 3
5 8 -0.04 165 14.78 253 617 4.01 / 704.82 2 2
Average= 3.89
(KJ/cycle)

Cycle 179 GMT 16/10/2024 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 31 14.74 426 195 0.19 / 697.02 2 3
2 7 2004.60 53 14.64 3030 2351 2.55 / 699.37 2 2
3 13 1046.04 20 14.58 1778 518 3.06 / 699.89 2 3
4 13 450.08 20 14.69 941 276 3.34 / 700.16 2 3
5 8 0.12 165 14.77 268 653 3.99 / 700.82 2 3
Average= 3.89
(KJ/cycle)

Cycle 178 GMT 6/10/2024 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 31 14.75 407 186 0.19 / 693.10 2 3
2 7 2004.08 52 14.64 3034 2310 2.50 / 695.41 2 2
3 13 1036.64 20 14.58 1753 511 3.01 / 695.92 2 3
4 13 319.20 20 14.73 740 218 3.23 / 696.14 2 3
5 8 0.16 165 14.78 238 580 3.81 / 696.72 2 2
6 14 0.16 30 14.75 241 107 3.91 / 696.82 2 3
Average= 3.89
(KJ/cycle)

Cycle 177 GMT 26/ 9/2024 20:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 30 14.74 428 189 0.19 / 689.23 2 3
2 7 2008.40 52 14.62 3043 2313 2.50 / 691.54 2 2
3 13 1034.32 20 14.58 1752 511 3.01 / 692.05 2 3
4 13 434.80 20 14.70 912 268 3.28 / 692.32 2 3
5 8 -0.36 165 14.78 243 593 3.87 / 692.91 2 3
Average= 3.89
(KJ/cycle)

Cycle 176 GMT 17/ 9/2024 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 30 14.74 422 187 0.19 / 685.37 2 3
2 7 2010.04 53 14.64 3041 2360 2.55 / 687.73 2 2
3 13 1036.76 20 14.58 1753 511 3.06 / 688.24 2 3
4 13 309.96 20 14.73 734 216 3.27 / 688.45 2 3
5 8 0.12 165 14.77 239 582 3.86 / 689.04 2 3
Average= 3.89
(KJ/cycle)

Cycle 175 GMT 7/ 9/2024 7:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 30 14.74 440 195 0.19 / 681.49 2 3
2 7 2010.48 53 14.63 3029 2349 2.54 / 683.84 2 2
3 13 1037.20 20 14.57 1753 511 3.05 / 684.35 2 3
4 13 426.88 20 14.69 893 262 3.32 / 684.61 2 3
5 8 -0.24 165 14.78 234 571 3.89 / 685.18 2 3
Average= 3.89
(KJ/cycle)

Cycle 174 GMT 28/ 8/2024 12:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 30 14.74 438 194 0.19 / 677.64 2 3
2 7 2003.56 53 14.63 3017 2339 2.53 / 679.98 2 2
3 13 1025.12 20 14.58 1738 507 3.04 / 680.48 2 4
4 13 302.84 20 14.74 720 212 3.25 / 680.70 2 3
5 8 0.04 165 14.78 245 597 3.85 / 681.29 2 2
Average= 3.89
(KJ/cycle)

Cycle 173 GMT 18/ 8/2024 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 30 14.74 444 196 0.20 / 673.74 2 3
2 7 2004.68 53 14.63 3018 2340 2.54 / 676.08 2 2
3 13 1025.92 20 14.58 1736 506 3.04 / 676.59 2 3
4 13 419.00 20 14.69 887 261 3.30 / 676.85 2 3
5 8 0.12 165 14.77 244 595 3.90 / 677.44 2 3
Average= 3.89
(KJ/cycle)

Cycle 172 GMT 8/ 8/2024 23:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 30 14.75 421 186 0.19 / 669.75 2 3
2 7 2009.04 53 14.63 3029 2349 2.53 / 672.10 2 2
3 13 1050.64 20 14.58 1774 517 3.05 / 672.62 2 3
4 13 323.56 20 14.73 749 221 3.27 / 672.84 2 3
5 8 0.40 165 14.79 245 598 3.87 / 673.44 2 2
6 14 0.40 30 14.77 246 109 3.98 / 673.55 2 2
Average= 3.89
(KJ/cycle)

Cycle 171 GMT 30/ 7/2024 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 30 14.74 419 185 0.19 / 665.82 2 3
2 7 2004.48 53 14.62 3018 2339 2.52 / 668.16 2 2
3 13 1038.44 20 14.58 1748 510 3.03 / 668.67 2 3
4 13 323.08 20 14.73 741 218 3.25 / 668.89 2 3
5 8 -0.76 165 14.78 235 573 3.82 / 669.46 2 5
6 14 -0.76 30 14.76 237 105 3.93 / 669.57 2 2
Average= 3.89
(KJ/cycle)

Cycle 170 GMT 20/ 7/2024 9:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 30 14.75 398 176 0.18 / 661.90 2 3
2 7 2009.88 53 14.63 3027 2347 2.52 / 664.25 2 2
3 13 1045.40 20 14.57 1767 515 3.04 / 664.76 2 3
4 13 450.64 20 14.69 927 272 3.31 / 665.04 2 3
5 8 -0.16 165 14.78 246 600 3.91 / 665.64 2 3
Average= 3.89
(KJ/cycle)

Cycle 169 GMT 10/ 7/2024 14:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 30 14.75 426 189 0.19 / 658.04 2 3
2 7 2008.92 53 14.63 3025 2346 2.53 / 660.39 2 2
3 13 1028.20 20 14.59 1732 505 3.04 / 660.89 2 4
4 13 421.56 20 14.71 882 259 3.30 / 661.15 2 3
5 8 0.16 165 14.79 235 573 3.87 / 661.73 2 3
Average= 3.89
(KJ/cycle)

Cycle 168 GMT 30/ 6/2024 19:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 14.75 412 182 0.18 / 654.19 2 3
2 7 2011.04 53 14.63 3029 2349 2.53 / 656.54 2 2
3 13 1045.28 20 14.58 1755 512 3.04 / 657.05 2 3
4 13 331.48 20 14.73 755 222 3.27 / 657.27 2 3
5 8 0.20 165 14.79 238 581 3.85 / 657.85 2 3
Average= 3.89
(KJ/cycle)

Cycle 167 GMT 21/ 6/2024 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 30 14.74 429 190 0.19 / 650.36 2 3
2 7 2003.88 53 14.64 3018 2342 2.53 / 652.70 2 2
3 13 1029.04 20 14.59 1737 507 3.04 / 653.21 2 3
4 13 311.68 20 14.74 728 215 3.25 / 653.42 2 3
5 8 0.08 165 14.79 239 583 3.84 / 654.01 2 3
Average= 3.89
(KJ/cycle)

Cycle 166 GMT 11/ 6/2024 5: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 30 14.74 434 192 0.19 / 646.43 2 3
2 7 2009.72 53 14.63 3035 2353 2.55 / 648.78 2 2
3 13 1044.60 20 14.59 1764 515 3.06 / 649.30 2 3
4 13 319.96 20 14.73 737 217 3.28 / 649.51 2 2
5 13 16.08 20 14.81 262 78 3.35 / 649.59 2 3
6 8 0.04 165 14.78 238 580 3.94 / 650.17 2 3
Average= 3.89
(KJ/cycle)

Cycle 165 GMT 1/ 6/2024 9:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.75 407 180 0.18 / 642.31 2 3
2 7 2008.72 53 14.63 3026 2346 2.53 / 644.65 2 2
3 13 1033.72 20 14.58 1746 509 3.04 / 645.16 2 4
4 13 438.12 20 14.70 907 267 3.30 / 645.43 2 3
5 13 22.76 20 14.81 281 83 3.39 / 645.51 2 2
6 8 -0.28 165 14.77 251 612 4.00 / 646.12 2 3
7 14 -0.28 30 14.74 253 112 4.11 / 646.24 2 3
Average= 3.89
(KJ/cycle)

Cycle 164 GMT 22/ 5/2024 14:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 30 14.75 412 182 0.18 / 638.32 2 3
2 7 2006.28 53 14.63 3023 2344 2.53 / 640.67 2 2
3 13 1037.08 20 14.58 1744 509 3.03 / 641.18 2 3
4 13 432.16 20 14.70 904 266 3.30 / 641.44 2 4
5 8 0.16 165 14.78 237 578 3.88 / 642.02 2 3
6 14 0.16 30 14.76 239 106 3.98 / 642.13 2 3
Average= 3.89
(KJ/cycle)

Cycle 163 GMT 12/ 5/2024 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.60 30 14.73 436 193 0.19 / 634.38 2 3
2 7 2006.40 53 14.63 3035 2353 2.55 / 636.74 2 2
3 13 1037.08 20 14.59 1761 514 3.06 / 637.25 2 3
4 13 326.20 20 14.74 751 221 3.28 / 637.47 2 3
5 13 14.68 20 14.81 260 77 3.36 / 637.55 2 2
6 8 -0.20 165 14.78 243 593 3.95 / 638.14 2 4
Average= 3.89
(KJ/cycle)

Cycle 162 GMT 3/ 5/2024 0:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 14.73 410 181 0.18 / 630.43 2 3
2 7 2012.92 53 14.63 3038 2356 2.54 / 632.79 2 2
3 13 1038.40 20 14.58 1766 515 3.05 / 633.30 2 4
4 13 320.68 20 14.72 749 221 3.27 / 633.52 2 3
5 13 17.12 20 14.80 270 80 3.35 / 633.60 2 3
6 8 0.16 165 14.76 241 587 3.94 / 634.19 2 3
Average= 3.89
(KJ/cycle)

Cycle 161 GMT 23/ 4/2024 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 30 14.75 436 193 0.19 / 626.43 3 3
2 7 2003.84 53 14.62 3026 2345 2.54 / 628.77 2 2
3 13 1062.56 20 14.57 1788 521 3.06 / 629.29 2 4
4 13 465.40 20 14.69 963 283 3.34 / 629.58 2 3
5 13 27.44 20 14.80 285 84 3.43 / 629.66 2 2
6 8 -0.76 165 14.77 243 592 4.02 / 630.25 2 3
Average= 3.89
(KJ/cycle)

Cycle 160 GMT 13/ 4/2024 10:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 30 14.74 428 189 0.19 / 622.52 2 3
2 7 2002.56 53 14.63 3036 2354 2.54 / 624.87 2 2
3 13 1015.28 20 14.59 1728 504 3.05 / 625.37 2 3
4 13 410.36 20 14.71 881 259 3.31 / 625.63 2 3
5 8 0.24 165 14.79 246 600 3.91 / 626.23 2 3
Average= 3.89
(KJ/cycle)

Cycle 159 GMT 3/ 4/2024 16:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 14.76 396 175 0.18 / 618.46 3 3
2 7 2002.72 53 14.64 3035 2355 2.53 / 620.82 2 2
3 13 1159.92 20 14.56 1937 564 3.09 / 621.38 2 3
4 13 396.80 20 14.71 867 255 3.35 / 621.64 2 3
5 13 42.64 20 14.81 314 93 3.44 / 621.73 2 3
6 8 0.64 165 14.78 245 597 4.04 / 622.33 2 3
Average= 3.89
(KJ/cycle)

Cycle 158 GMT 24/ 3/2024 21:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 30 14.74 445 197 0.20 / 614.54 2 3
2 7 2006.76 53 14.64 3047 2364 2.56 / 616.90 2 2
3 13 1014.12 20 14.59 1714 500 3.06 / 617.40 2 4
4 13 299.16 20 14.73 717 211 3.27 / 617.61 2 3
5 13 25.96 20 14.80 285 84 3.36 / 617.70 2 3
6 8 -0.40 165 14.78 241 588 3.94 / 618.29 2 3
Average= 3.89
(KJ/cycle)

Cycle 157 GMT 15/ 3/2024 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 30 14.75 410 181 0.18 / 610.50 2 3
2 7 2003.40 53 14.64 3043 2361 2.54 / 612.86 2 2
3 13 1028.40 20 14.59 1761 514 3.06 / 613.37 2 3
4 13 421.68 20 14.71 901 265 3.32 / 613.64 2 3
5 13 42.16 20 14.81 314 93 3.41 / 613.73 2 3
6 8 -0.20 165 14.78 251 612 4.03 / 614.34 2 3
Average= 3.89
(KJ/cycle)

Cycle 156 GMT 5/ 3/2024 7:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.74 425 188 0.19 / 606.46 3 3
2 7 2004.24 53 14.64 3034 2354 2.54 / 608.82 2 2
3 13 1043.08 20 14.59 1767 516 3.06 / 609.33 2 3
4 13 432.92 20 14.71 920 271 3.33 / 609.60 2 3
5 13 42.52 20 14.81 316 94 3.42 / 609.70 2 3
6 8 -0.16 165 14.78 254 619 4.04 / 610.32 2 3
Average= 3.89
(KJ/cycle)

Cycle 155 GMT 24/ 2/2024 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 30 14.75 430 190 0.19 / 602.41 2 3
2 7 2005.64 53 14.64 3037 2356 2.55 / 604.77 2 2
3 13 1040.84 20 14.59 1761 514 3.06 / 605.28 2 3
4 13 435.88 20 14.71 912 268 3.33 / 605.55 2 3
5 13 22.76 20 14.81 295 87 3.42 / 605.64 2 2
6 8 -0.12 165 14.78 260 634 4.05 / 606.27 2 3
Average= 3.89
(KJ/cycle)

Cycle 154 GMT 14/ 2/2024 17:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 30 14.75 428 189 0.19 / 598.46 2 3
2 7 2010.60 53 14.63 3041 2358 2.55 / 600.82 2 2
3 13 1031.68 20 14.59 1752 511 3.06 / 601.33 2 4
4 13 307.32 20 14.74 726 214 3.27 / 601.54 2 3
5 13 30.16 20 14.81 288 85 3.36 / 601.63 2 3
6 8 -0.12 165 14.78 245 597 3.96 / 602.22 2 3
Average= 3.89
(KJ/cycle)

Cycle 153 GMT 4/ 2/2024 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 30 14.77 426 189 0.19 / 594.50 3 3
2 7 2008.96 53 14.64 3034 2354 2.54 / 596.85 2 2
3 13 1037.72 20 14.59 1765 515 3.06 / 597.37 2 4
4 13 316.64 20 14.75 743 219 3.28 / 597.59 2 3
5 13 32.32 20 14.82 289 86 3.36 / 597.67 2 3
6 8 0.36 165 14.79 244 595 3.96 / 598.27 2 3
Average= 3.88
(KJ/cycle)

Cycle 152 GMT 26/ 1/2024 1:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 30 14.76 445 197 0.20 / 590.48 2 3
2 7 2010.08 53 14.65 3042 2362 2.56 / 592.84 2 2
3 13 1037.24 20 14.59 1769 516 3.08 / 593.36 2 4
4 13 431.04 20 14.71 912 268 3.34 / 593.62 2 3
5 13 22.56 20 14.82 281 83 3.43 / 593.71 2 3
6 8 -0.12 165 14.79 247 603 4.03 / 594.31 2 2
Average= 3.88
(KJ/cycle)

Cycle 151 GMT 16/ 1/2024 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 30 14.76 427 189 0.19 / 586.52 2 3
2 7 2004.80 53 14.64 3017 2341 2.53 / 588.86 2 2
3 13 1027.72 20 14.60 1742 509 3.04 / 589.37 2 3
4 13 311.24 20 14.75 730 215 3.25 / 589.58 2 3
5 13 29.04 20 14.82 289 86 3.34 / 589.67 2 3
6 8 -0.28 165 14.79 251 613 3.95 / 590.28 2 3
Average= 3.88
(KJ/cycle)

Cycle 150 GMT 6/ 1/2024 6:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 30 14.77 407 180 0.18 / 582.61 2 3
2 7 2009.44 53 14.65 3036 2357 2.54 / 584.97 2 2
3 13 1024.40 20 14.60 1739 508 3.05 / 585.48 2 4
4 13 425.60 20 14.71 893 263 3.31 / 585.74 2 3
5 8 -0.04 165 14.80 240 586 3.89 / 586.33 2 3
Average= 3.88
(KJ/cycle)

Cycle 149 GMT 27/12/2023 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 14.76 412 182 0.18 / 578.73 2 3
2 7 2009.04 53 14.65 3021 2346 2.53 / 581.08 2 2
3 13 1027.36 20 14.60 1736 507 3.04 / 581.59 2 4
4 13 405.04 20 14.73 872 257 3.29 / 581.84 2 3
5 8 0.20 165 14.80 242 591 3.88 / 582.43 2 2
Average= 3.88
(KJ/cycle)

Cycle 148 GMT 17/12/2023 11:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 14.76 400 177 0.18 / 574.87 2 3
2 7 2009.84 53 14.65 3037 2358 2.54 / 577.23 2 2
3 13 1025.36 20 14.59 1739 507 3.04 / 577.73 2 4
4 13 318.36 20 14.74 745 220 3.26 / 577.95 2 3
5 8 0.40 165 14.79 245 598 3.86 / 578.55 2 2
Average= 3.88
(KJ/cycle)

Cycle 147 GMT 7/12/2023 14:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 30 14.77 436 193 0.19 / 570.91 2 3
2 7 2003.96 53 14.65 3032 2354 2.55 / 573.27 2 2
3 13 1044.28 20 14.61 1762 515 3.06 / 573.78 2 4
4 13 329.20 20 14.76 758 224 3.29 / 574.00 2 3
5 8 0.32 165 14.81 238 582 3.87 / 574.59 2 4
6 14 0.32 30 14.79 237 105 3.97 / 574.69 2 3
Average= 3.88
(KJ/cycle)

Cycle 146 GMT 27/11/2023 16:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 30 14.78 431 191 0.19 / 567.04 3 3
2 7 2004.12 53 14.66 3024 2350 2.54 / 569.39 2 2
3 13 1028.48 20 14.61 1749 511 3.05 / 569.90 2 3
4 13 312.24 20 14.76 732 216 3.27 / 570.12 2 3
5 8 0.64 165 14.81 246 601 3.87 / 570.72 2 3
Average= 3.88
(KJ/cycle)

Cycle 145 GMT 17/11/2023 19:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 30 14.76 409 181 0.18 / 563.03 2 3
2 7 2003.92 53 14.65 3021 2346 2.53 / 565.38 2 2
3 13 1024.20 20 14.61 1727 505 3.03 / 565.88 2 4
4 13 426.04 20 14.72 903 266 3.30 / 566.15 2 3
5 8 0.60 165 14.80 244 596 3.89 / 566.74 2 3
6 14 0.60 30 14.78 244 108 4.00 / 566.85 2 3
Average= 3.88
(KJ/cycle)

Cycle 144 GMT 7/11/2023 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 30 14.77 433 192 0.19 / 559.18 2 3
2 7 2009.48 53 14.64 3020 2343 2.54 / 561.53 2 2
3 13 1020.80 20 14.60 1724 503 3.04 / 562.03 2 4
4 13 309.60 20 14.76 721 213 3.25 / 562.24 2 3
5 8 0.20 165 14.80 248 606 3.86 / 562.85 2 3
Average= 3.88
(KJ/cycle)

Cycle 143 GMT 29/10/2023 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 30 14.77 421 187 0.19 / 555.23 3 3
2 7 2004.36 53 14.66 3021 2347 2.53 / 557.57 2 2
3 13 1012.36 20 14.62 1712 501 3.03 / 558.07 2 4
4 13 423.24 20 14.72 894 263 3.30 / 558.34 2 3
5 13 20.08 20 14.83 264 78 3.38 / 558.42 2 2
6 8 0.16 165 14.79 236 576 3.95 / 558.99 2 2
Average= 3.88
(KJ/cycle)

Cycle 142 GMT 19/10/2023 2:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.52 30 14.77 433 192 0.19 / 551.37 2 3
2 7 2007.64 53 14.64 3020 2343 2.54 / 553.71 2 2
3 13 1027.40 20 14.59 1741 508 3.04 / 554.22 2 3
4 13 308.96 20 14.76 740 218 3.26 / 554.44 2 3
5 8 -0.44 165 14.81 245 599 3.86 / 555.04 2 3
Average= 3.88
(KJ/cycle)

Cycle 141 GMT 9/10/2023 5: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 30 14.78 458 203 0.20 / 547.54 3 3
2 7 2004.32 52 14.65 3036 2313 2.52 / 549.85 2 2
3 13 1043.68 20 14.60 1755 512 3.03 / 550.36 2 4
4 13 329.36 20 14.75 757 223 3.25 / 550.59 2 3
5 8 0.12 165 14.81 242 591 3.84 / 551.18 2 3
Average= 3.88
(KJ/cycle)

Cycle 140 GMT 29/ 9/2023 7:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 30 14.79 416 185 0.18 / 543.60 2 3
2 7 2002.72 53 14.66 3022 2348 2.53 / 545.95 2 2
3 13 1013.36 20 14.62 1710 500 3.03 / 546.45 2 3
4 13 422.00 20 14.73 879 259 3.29 / 546.71 2 3
5 8 0.20 165 14.81 258 630 3.92 / 547.34 2 2
Average= 3.88
(KJ/cycle)

Cycle 139 GMT 19/ 9/2023 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 30 14.79 403 179 0.18 / 539.67 3 3
2 7 2002.32 53 14.66 3028 2353 2.53 / 542.03 2 2
3 13 1028.00 20 14.61 1738 508 3.04 / 542.53 2 3
4 13 309.68 20 14.76 718 212 3.25 / 542.75 2 3
5 8 0.04 165 14.83 231 565 3.82 / 543.31 2 3
6 14 0.04 30 14.81 231 103 3.92 / 543.41 2 3
Average= 3.88
(KJ/cycle)

Cycle 138 GMT 9/ 9/2023 12:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 30 14.79 436 193 0.19 / 535.88 3 3
2 7 2004.04 53 14.65 3020 2345 2.54 / 538.22 2 2
3 13 926.36 20 14.64 1606 470 3.01 / 538.69 2 3
4 13 358.36 20 14.76 791 234 3.24 / 538.93 2 3
5 8 -0.04 165 14.81 232 567 3.81 / 539.50 2 3
Average= 3.88
(KJ/cycle)

Cycle 137 GMT 30/ 8/2023 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 30 14.79 426 189 0.19 / 531.93 2 3
2 7 2003.04 53 14.65 3018 2343 2.53 / 534.28 2 2
3 13 1025.32 20 14.62 1740 509 3.04 / 534.79 2 3
4 13 312.88 20 14.76 732 216 3.26 / 535.00 2 3
5 8 -0.28 165 14.82 237 580 3.84 / 535.58 2 3
6 14 -0.28 30 14.79 237 105 3.94 / 535.69 2 3
Average= 3.88
(KJ/cycle)

Cycle 136 GMT 20/ 8/2023 17:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 30 14.78 417 185 0.18 / 527.90 2 3
2 7 2004.04 53 14.65 3030 2353 2.54 / 530.25 2 2
3 13 1139.88 20 14.58 1899 554 3.09 / 530.80 2 3
4 13 382.16 20 14.74 842 248 3.34 / 531.05 2 3
5 8 -0.20 165 14.82 239 584 3.92 / 531.64 2 2
6 14 -0.20 30 14.81 244 108 4.03 / 531.74 2 3
Average= 3.88
(KJ/cycle)

Cycle 135 GMT 10/ 8/2023 20:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 30 14.78 399 177 0.18 / 524.05 3 3
2 7 2003.88 53 14.65 3039 2360 2.54 / 526.41 2 2
3 13 1019.76 20 14.62 1735 507 3.04 / 526.91 2 4
4 13 300.12 20 14.76 716 211 3.26 / 527.13 2 3
5 8 0.20 165 14.82 240 587 3.84 / 527.71 2 3
Average= 3.88
(KJ/cycle)

Cycle 134 GMT 31/ 7/2023 22:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 30 14.79 413 183 0.18 / 520.11 2 3
2 7 2003.88 52 14.66 3031 2311 2.49 / 522.42 2 2
3 13 1015.84 20 14.62 1736 508 3.00 / 522.93 2 5
4 13 414.96 20 14.73 883 260 3.26 / 523.19 2 3
5 8 0.16 165 14.81 236 577 3.84 / 523.77 2 2
6 14 0.16 30 14.79 236 105 3.94 / 523.87 2 3
Average= 3.88
(KJ/cycle)

Cycle 133 GMT 22/ 7/2023 1:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 29 14.79 412 177 0.18 / 516.25 3 3
2 7 2008.48 53 14.65 3043 2363 2.54 / 518.61 2 2
3 13 1029.16 20 14.60 1751 511 3.05 / 519.12 2 5
4 13 302.84 20 14.77 722 213 3.26 / 519.33 2 3
5 8 0.36 165 14.82 243 594 3.86 / 519.93 2 2
Average= 3.88
(KJ/cycle)

Cycle 132 GMT 12/ 7/2023 4: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 29 14.78 405 174 0.17 / 512.41 3 3
2 7 2009.92 53 14.64 3040 2359 2.53 / 514.77 2 2
3 13 1027.72 20 14.61 1746 510 3.04 / 515.28 2 3
4 13 311.72 20 14.77 744 220 3.26 / 515.50 2 3
5 8 0.48 165 14.82 233 570 3.83 / 516.07 2 3
Average= 3.88
(KJ/cycle)

Cycle 131 GMT 2/ 7/2023 6:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 29 14.78 424 182 0.18 / 508.45 2 3
2 7 2003.24 53 14.67 3044 2367 2.55 / 510.81 2 2
3 13 1012.52 20 14.62 1724 504 3.05 / 511.32 2 3
4 13 407.84 20 14.74 872 257 3.31 / 511.57 2 3
5 13 22.08 20 14.84 273 81 3.39 / 511.66 2 2
6 8 -0.52 165 14.81 238 582 3.97 / 512.24 2 3
Average= 3.88
(KJ/cycle)

Cycle 130 GMT 22/ 6/2023 8:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 29 14.78 401 172 0.17 / 504.46 2 3
2 7 2009.84 53 14.65 3052 2370 2.54 / 506.83 2 2
3 13 1013.80 20 14.61 1731 506 3.05 / 507.34 2 3
4 13 399.36 20 14.74 862 254 3.30 / 507.59 2 3
5 13 45.60 20 14.83 303 90 3.39 / 507.68 2 3
6 8 -0.36 165 14.81 239 584 3.98 / 508.26 2 3
Average= 3.88
(KJ/cycle)

Cycle 129 GMT 12/ 6/2023 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 29 14.79 407 175 0.17 / 500.57 3 3
2 7 2004.72 53 14.65 3040 2360 2.53 / 502.93 2 2
3 13 1017.16 20 14.62 1727 505 3.04 / 503.44 2 6
4 13 402.16 20 14.74 874 258 3.30 / 503.70 2 3
5 8 0.16 165 14.83 242 592 3.89 / 504.29 2 4
Average= 3.88
(KJ/cycle)

Cycle 128 GMT 2/ 6/2023 13:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 14.76 423 181 0.18 / 496.62 3 3
2 7 2011.60 53 14.65 3047 2366 2.55 / 498.99 2 2
3 13 1038.12 20 14.61 1762 515 3.06 / 499.50 2 3
4 13 311.32 20 14.77 732 216 3.28 / 499.72 2 3
5 13 32.76 20 14.84 292 87 3.36 / 499.80 2 2
6 8 -0.08 165 14.82 243 594 3.96 / 500.40 2 3
Average= 3.88
(KJ/cycle)

Cycle 127 GMT 23/ 5/2023 16:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 29 14.78 432 185 0.19 / 492.69 3 3
2 7 2003.28 53 14.66 3033 2357 2.54 / 495.05 2 2
3 13 908.28 20 14.63 1587 464 3.01 / 495.51 2 5
4 13 337.92 20 14.75 784 231 3.24 / 495.74 2 3
5 13 19.72 20 14.83 280 83 3.32 / 495.82 2 2
6 8 -0.04 165 14.81 252 616 3.94 / 496.44 2 3
Average= 3.88
(KJ/cycle)

Cycle 126 GMT 13/ 5/2023 18:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 29 14.79 406 174 0.17 / 488.72 3 3
2 7 2010.52 52 14.66 3035 2314 2.49 / 491.04 2 2
3 13 1040.04 20 14.61 1761 515 3.00 / 491.55 2 4
4 13 314.36 20 14.79 723 214 3.22 / 491.76 2 3
5 13 37.36 20 14.84 309 92 3.31 / 491.86 2 3
6 8 0.04 165 14.81 265 648 3.96 / 492.50 2 3
Average= 3.88
(KJ/cycle)

Cycle 125 GMT 3/ 5/2023 21:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 29 14.78 397 170 0.17 / 484.81 3 3
2 7 2003.92 53 14.66 3025 2350 2.52 / 487.16 2 2
3 13 1024.56 20 14.63 1738 509 3.03 / 487.66 2 4
4 13 302.20 20 14.78 726 215 3.24 / 487.88 2 3
5 13 39.84 20 14.84 301 89 3.33 / 487.97 2 2
6 8 0.12 165 14.83 237 580 3.91 / 488.55 2 3
Average= 3.88
(KJ/cycle)

Cycle 124 GMT 23/ 4/2023 23:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 14.78 396 170 0.17 / 480.84 3 3
2 7 2010.36 53 14.67 3042 2365 2.53 / 483.20 2 2
3 13 1015.48 20 14.63 1732 507 3.04 / 483.71 2 3
4 13 413.12 20 14.75 883 260 3.30 / 483.97 2 3
5 13 45.84 20 14.84 311 92 3.39 / 484.06 2 2
6 8 0.36 165 14.82 235 575 3.97 / 484.64 2 4
Average= 3.88
(KJ/cycle)

Cycle 123 GMT 14/ 4/2023 2:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 29 14.79 406 174 0.17 / 476.91 3 3
2 7 2003.60 53 14.67 3017 2346 2.52 / 479.25 2 2
3 13 1006.88 20 14.64 1715 502 3.02 / 479.76 2 3
4 13 410.84 20 14.76 876 259 3.28 / 480.01 2 3
5 13 49.48 20 14.85 310 92 3.37 / 480.11 2 3
6 8 0.00 165 14.83 229 560 3.93 / 480.67 2 3
Average= 3.88
(KJ/cycle)

Cycle 122 GMT 4/ 4/2023 4:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 29 14.80 408 175 0.18 / 472.92 3 3
2 7 2011.64 53 14.67 3037 2361 2.54 / 475.28 2 2
3 13 1026.44 20 14.63 1737 508 3.04 / 475.79 2 3
4 13 428.28 20 14.75 898 265 3.31 / 476.06 2 3
5 13 53.24 20 14.85 320 95 3.40 / 476.15 2 3
6 8 -0.20 165 14.82 238 582 3.99 / 476.73 2 3
Average= 3.88
(KJ/cycle)

Cycle 121 GMT 25/ 3/2023 7:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 29 14.79 418 179 0.18 / 469.02 3 3
2 7 2004.52 53 14.66 3029 2353 2.53 / 471.38 2 2
3 13 910.96 20 14.64 1596 467 3.00 / 471.84 2 6
4 13 328.12 20 14.78 760 225 3.22 / 472.07 2 3
5 13 36.52 20 14.85 297 88 3.31 / 472.16 2 3
6 8 0.12 165 14.83 241 590 3.90 / 472.75 2 4
Average= 3.87
(KJ/cycle)

Cycle 120 GMT 15/ 3/2023 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 29 14.80 398 171 0.17 / 465.06 3 3
2 7 2002.76 53 14.68 3027 2355 2.53 / 467.41 2 2
3 13 1035.04 20 14.63 1742 510 3.04 / 467.92 2 4
4 13 314.08 20 14.79 732 217 3.25 / 468.14 2 3
5 13 38.68 20 14.84 308 91 3.34 / 468.23 2 2
6 8 0.52 165 14.82 251 614 3.96 / 468.84 2 3
Average= 3.87
(KJ/cycle)

Cycle 119 GMT 5/ 3/2023 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 29 14.80 402 173 0.17 / 461.09 3 3
2 7 2004.28 53 14.67 3040 2364 2.54 / 463.45 2 2
3 13 1018.40 20 14.64 1729 506 3.04 / 463.96 2 3
4 13 417.04 20 14.75 883 260 3.30 / 464.22 2 3
5 13 51.96 20 14.84 319 95 3.40 / 464.31 2 3
6 8 -0.56 165 14.83 235 575 3.97 / 464.89 2 3
Average= 3.87
(KJ/cycle)

Cycle 118 GMT 23/ 2/2023 14:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 29 14.79 421 181 0.18 / 457.15 3 3
2 7 2007.16 52 14.67 3048 2325 2.51 / 459.47 2 2
3 13 1025.40 20 14.62 1749 511 3.02 / 459.98 2 3
4 13 413.32 20 14.75 882 260 3.28 / 460.24 2 3
5 13 29.88 20 14.85 285 85 3.36 / 460.33 2 3
6 8 0.36 165 14.82 240 587 3.95 / 460.91 2 3
Average= 3.87
(KJ/cycle)

Cycle 117 GMT 13/ 2/2023 17: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 29 14.79 426 183 0.18 / 453.10 3 3
2 7 2008.00 53 14.67 3032 2357 2.54 / 455.46 2 2
3 13 1022.68 20 14.63 1737 508 3.05 / 455.97 2 4
4 13 415.28 20 14.75 888 262 3.31 / 456.23 2 3
5 13 50.24 20 14.83 333 99 3.41 / 456.33 2 3
6 8 -0.28 165 14.82 260 636 4.04 / 456.97 2 4
Average= 3.87
(KJ/cycle)

Cycle 116 GMT 3/ 2/2023 19:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 29 14.82 403 173 0.17 / 449.05 3 3
2 7 2003.04 53 14.68 3024 2353 2.53 / 451.40 2 2
3 13 1163.96 20 14.60 1924 562 3.09 / 451.96 2 3
4 13 396.56 20 14.77 861 254 3.34 / 452.22 2 3
5 13 42.72 20 14.86 313 93 3.44 / 452.31 2 2
6 8 0.60 165 14.83 250 612 4.05 / 452.92 2 3
Average= 3.87
(KJ/cycle)

Cycle 115 GMT 24/ 1/2023 22: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 29 14.80 424 182 0.18 / 445.11 3 3
2 7 2003.96 53 14.67 3035 2360 2.54 / 447.47 2 2
3 13 1013.48 20 14.64 1722 504 3.05 / 447.97 2 5
4 13 294.84 20 14.81 711 211 3.26 / 448.18 2 3
5 13 28.64 20 14.86 293 87 3.34 / 448.27 2 3
6 8 0.12 165 14.83 247 604 3.95 / 448.87 2 3
Average= 3.87
(KJ/cycle)

Cycle 114 GMT 15/ 1/2023 0:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 30 14.81 399 177 0.18 / 441.17 3 3
2 7 2009.88 53 14.67 3040 2364 2.54 / 443.53 2 2
3 13 1017.08 20 14.64 1727 506 3.05 / 444.03 2 3
4 13 298.76 20 14.79 704 208 3.25 / 444.24 2 2
5 13 30.40 20 14.86 288 86 3.34 / 444.33 2 2
6 8 0.32 165 14.83 244 597 3.94 / 444.93 2 3
Average= 3.87
(KJ/cycle)

Cycle 113 GMT 5/ 1/2023 2:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 30 14.80 432 192 0.19 / 437.22 3 3
2 7 2010.36 53 14.67 3046 2368 2.56 / 439.59 2 2
3 13 1017.28 20 14.64 1735 508 3.07 / 440.10 2 4
4 13 287.56 20 14.80 703 208 3.28 / 440.31 2 3
5 13 26.64 20 14.86 285 85 3.36 / 440.39 2 3
6 8 0.32 165 14.84 243 595 3.96 / 440.99 2 3
Average= 3.87
(KJ/cycle)

Cycle 112 GMT 26/12/2022 5:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 14.79 401 178 0.18 / 433.37 2 3
2 7 2003.00 53 14.68 3027 2355 2.53 / 435.73 2 2
3 13 1013.52 20 14.64 1729 506 3.04 / 436.23 2 4
4 13 289.40 20 14.80 698 207 3.25 / 436.44 2 3
5 8 -0.16 165 14.83 242 592 3.84 / 437.03 2 2
Average= 3.87
(KJ/cycle)

Cycle 111 GMT 16/12/2022 7:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 29 14.82 450 193 0.19 / 429.40 3 3
2 3 1021.32 1 14.94 1809 27 0.22 / 429.43 2 3
3 7 2009.20 53 14.68 3046 2370 2.59 / 431.80 2 2
4 13 1022.44 20 14.64 1740 509 3.10 / 432.31 2 3
5 13 311.44 20 14.80 732 217 3.32 / 432.53 2 3
6 13 29.20 20 14.87 288 86 3.40 / 432.61 2 2
7 8 -0.04 165 14.84 238 583 3.98 / 433.19 2 3
Average= 3.87
(KJ/cycle)

Cycle 110 GMT 6/12/2022 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 14.82 404 174 0.17 / 425.44 2 3
2 7 2009.08 53 14.68 3040 2365 2.54 / 427.81 2 2
3 13 1017.20 20 14.65 1738 509 3.05 / 428.32 2 5
4 13 404.92 20 14.77 873 258 3.31 / 428.57 2 3
5 8 0.56 165 14.85 259 635 3.94 / 429.21 2 3
Average= 3.87
(KJ/cycle)

Cycle 109 GMT 26/11/2022 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 29 14.82 420 181 0.18 / 421.61 2 3
2 7 2010.16 53 14.68 3047 2371 2.55 / 423.98 2 2
3 13 910.96 20 14.67 1594 468 3.02 / 424.45 2 3
4 13 330.68 20 14.80 768 227 3.25 / 424.67 2 3
5 8 0.32 165 14.86 243 596 3.84 / 425.27 2 3
Average= 3.87
(KJ/cycle)

Cycle 108 GMT 16/11/2022 15:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 14.82 425 183 0.18 / 417.70 2 3
2 7 2010.80 53 14.67 3055 2375 2.56 / 420.08 2 2
3 13 1020.36 20 14.63 1760 515 3.07 / 420.59 2 5
4 13 306.80 20 14.80 733 217 3.29 / 420.81 2 3
5 8 0.20 165 14.84 252 617 3.91 / 421.43 2 3
Average= 3.87
(KJ/cycle)

Cycle 107 GMT 6/11/2022 17:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 29 14.82 402 173 0.17 / 413.83 2 3
2 7 2008.28 53 14.68 3043 2368 2.54 / 416.20 2 2
3 13 1031.16 20 14.66 1748 513 3.05 / 416.71 2 4
4 13 319.28 20 14.81 754 223 3.28 / 416.93 2 3
5 8 0.08 165 14.87 240 589 3.87 / 417.52 2 3
Average= 3.87
(KJ/cycle)

Cycle 106 GMT 27/10/2022 20:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 14.83 427 184 0.18 / 409.93 3 3
2 7 2005.00 53 14.69 3046 2372 2.56 / 412.30 2 2
3 13 1013.92 20 14.65 1734 508 3.06 / 412.81 2 3
4 13 396.00 20 14.79 859 254 3.32 / 413.06 2 3
5 8 -0.16 165 14.85 241 591 3.91 / 413.65 2 3
Average= 3.87
(KJ/cycle)

Cycle 105 GMT 17/10/2022 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 14.82 424 182 0.18 / 406.01 2 3
2 7 2008.60 52 14.68 3056 2333 2.52 / 408.35 2 2
3 13 1015.80 20 14.66 1738 510 3.02 / 408.86 2 3
4 13 409.24 20 14.78 874 258 3.28 / 409.11 2 3
5 8 -0.24 165 14.86 258 633 3.92 / 409.75 2 3
Average= 3.87
(KJ/cycle)

Cycle 104 GMT 8/10/2022 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 29 14.81 464 199 0.20 / 402.06 2 3
2 7 2009.84 53 14.69 3061 2383 2.58 / 404.44 2 2
3 13 1017.64 20 14.66 1744 511 3.09 / 404.95 2 4
4 13 406.44 20 14.79 881 261 3.35 / 405.21 2 3
5 8 0.08 165 14.86 252 618 3.97 / 405.83 2 3
Average= 3.87
(KJ/cycle)

Cycle 103 GMT 28/ 9/2022 3:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 29 14.83 420 181 0.18 / 398.05 2 3
2 7 2004.88 53 14.68 3040 2365 2.55 / 400.42 2 2
3 13 1041.08 20 14.64 1782 522 3.07 / 400.94 2 5
4 13 428.16 20 14.77 916 271 3.34 / 401.21 2 3
5 8 0.00 165 14.85 264 647 3.99 / 401.86 2 2
Average= 3.86
(KJ/cycle)

Cycle 102 GMT 18/ 9/2022 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 29 14.83 416 179 0.18 / 394.17 2 3
2 7 2010.96 53 14.68 3048 2371 2.55 / 396.54 2 2
3 13 1031.44 20 14.65 1761 516 3.07 / 397.06 2 4
4 13 301.20 20 14.81 716 212 3.28 / 397.27 2 3
5 8 -0.52 165 14.87 247 606 3.88 / 397.87 2 2
Average= 3.86
(KJ/cycle)

Cycle 101 GMT 8/ 9/2022 8:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 29 14.83 440 189 0.19 / 390.15 2 3
2 7 2003.76 53 14.69 3039 2366 2.56 / 392.51 2 2
3 13 1031.48 20 14.65 1765 517 3.07 / 393.03 2 3
4 13 430.04 20 14.78 911 269 3.34 / 393.30 2 3
5 13 22.32 20 14.88 272 81 3.42 / 393.38 2 2
6 8 0.40 165 14.86 249 611 4.03 / 393.99 2 3
Average= 3.86
(KJ/cycle)

Cycle 100 GMT 29/ 8/2022 11:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 29 14.82 451 194 0.19 / 386.19 2 3
2 7 2006.00 53 14.69 3041 2368 2.56 / 388.56 2 2
3 13 1023.64 20 14.65 1754 514 3.08 / 389.07 2 3
4 13 414.52 20 14.78 901 266 3.34 / 389.34 2 3
5 8 0.04 165 14.87 251 616 3.96 / 389.96 2 3
Average= 3.86
(KJ/cycle)

Cycle 99 GMT 19/ 8/2022 14: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 29 14.85 420 181 0.18 / 382.25 2 3
2 7 2007.48 53 14.70 3032 2362 2.54 / 384.61 2 2
3 13 1006.24 20 14.66 1724 505 3.05 / 385.12 2 4
4 13 400.00 20 14.79 879 260 3.31 / 385.38 2 3
5 8 -0.20 165 14.87 253 621 3.93 / 386.00 2 3
Average= 3.86
(KJ/cycle)

Cycle 98 GMT 9/ 8/2022 16:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 29 14.84 411 177 0.18 / 378.21 2 3
2 7 2011.28 53 14.71 3037 2368 2.54 / 380.58 2 2
3 13 1025.20 20 14.67 1749 513 3.06 / 381.09 2 5
4 13 416.32 20 14.80 899 266 3.32 / 381.36 2 3
5 8 -0.04 165 14.88 246 604 3.93 / 381.96 2 3
6 14 -0.04 30 14.85 243 108 4.04 / 382.07 2 3
Average= 3.86
(KJ/cycle)

Cycle 97 GMT 30/ 7/2022 18:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 29 14.86 400 172 0.17 / 374.35 3 3
2 7 2012.04 52 14.71 3023 2312 2.48 / 376.66 2 2
3 13 1024.80 20 14.67 1753 514 3.00 / 377.17 2 3
4 13 414.00 20 14.79 904 267 3.27 / 377.44 2 3
5 8 0.00 165 14.88 241 592 3.86 / 378.03 2 3
Average= 3.86
(KJ/cycle)

Cycle 96 GMT 20/ 7/2022 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 29 14.85 442 190 0.19 / 370.42 3 3
2 7 2009.56 52 14.70 3054 2334 2.52 / 372.76 2 2
3 13 1017.24 20 14.68 1739 511 3.04 / 373.27 2 3
4 13 289.68 20 14.85 704 209 3.24 / 373.48 2 3
5 8 0.12 165 14.91 240 590 3.83 / 374.07 2 3
6 14 0.12 30 14.88 241 108 3.94 / 374.18 2 4
Average= 3.86
(KJ/cycle)

Cycle 95 GMT 10/ 7/2022 23:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 29 14.86 408 176 0.18 / 366.59 3 3
2 7 2012.52 52 14.71 3039 2325 2.50 / 368.91 2 2
3 13 917.68 20 14.70 1597 470 2.97 / 369.38 2 5
4 13 332.64 20 14.82 782 232 3.20 / 369.61 2 3
5 8 0.00 165 14.89 253 622 3.82 / 370.23 2 3
Average= 3.86
(KJ/cycle)

Cycle 94 GMT 1/ 7/2022 1:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 29 14.84 438 188 0.19 / 362.56 3 3
2 7 2008.44 53 14.71 3031 2363 2.55 / 364.92 2 2
3 13 903.16 20 14.71 1582 465 3.02 / 365.39 2 4
4 13 322.56 20 14.84 756 224 3.24 / 365.61 2 3
5 13 18.28 20 14.91 270 81 3.32 / 365.69 2 3
6 8 0.76 165 14.89 247 607 3.93 / 366.30 2 4
7 14 0.76 30 14.87 251 112 4.04 / 366.41 3 3
Average= 3.86
(KJ/cycle)

Cycle 93 GMT 21/ 6/2022 4:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 29 14.85 436 188 0.19 / 358.46 3 3
2 7 2007.40 53 14.69 3058 2381 2.57 / 360.84 2 2
3 13 1024.48 20 14.68 1748 513 3.08 / 361.35 2 3
4 13 412.88 20 14.81 892 264 3.35 / 361.61 2 3
5 13 45.12 20 14.90 338 101 3.45 / 361.72 2 3
6 8 -0.32 165 14.88 266 653 4.10 / 362.37 2 4
Average= 3.85
(KJ/cycle)

Cycle 92 GMT 11/ 6/2022 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 29 14.86 425 183 0.18 / 354.37 3 3
2 7 2004.40 53 14.72 3028 2362 2.55 / 356.73 2 2
3 13 1018.40 20 14.68 1743 512 3.06 / 357.24 2 3
4 13 406.80 20 14.81 890 264 3.32 / 357.50 2 3
5 13 48.76 20 14.91 350 104 3.43 / 357.61 2 3
6 8 -0.24 165 14.88 269 660 4.09 / 358.27 2 3
Average= 3.85
(KJ/cycle)

Cycle 91 GMT 1/ 6/2022 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 29 14.85 446 192 0.19 / 350.44 3 3
2 7 2005.04 52 14.70 3032 2318 2.51 / 352.76 2 2
3 13 1005.96 20 14.69 1720 505 3.02 / 353.27 2 3
4 13 282.08 20 14.86 690 205 3.22 / 353.47 2 3
5 13 63.00 20 14.90 342 102 3.32 / 353.57 2 3
6 8 -0.12 165 14.89 248 609 3.93 / 354.18 2 3
Average= 3.85
(KJ/cycle)

Cycle 90 GMT 22/ 5/2022 11:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 29 14.85 403 174 0.17 / 346.38 3 3
2 7 2010.00 53 14.73 3038 2372 2.55 / 348.75 2 2
3 13 1006.52 20 14.69 1727 507 3.05 / 349.26 2 3
4 13 401.84 20 14.82 878 260 3.31 / 349.52 2 3
5 13 53.36 20 14.90 345 103 3.42 / 349.62 2 3
6 8 0.08 165 14.88 258 633 4.05 / 350.25 2 3
Average= 3.85
(KJ/cycle)

Cycle 89 GMT 12/ 5/2022 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 29 14.87 412 178 0.18 / 342.35 3 3
2 7 2003.80 53 14.70 3035 2365 2.54 / 344.72 2 2
3 13 1004.64 20 14.69 1715 504 3.05 / 345.22 2 3
4 13 397.80 20 14.82 867 257 3.30 / 345.48 2 3
5 13 50.12 20 14.91 334 100 3.40 / 345.58 2 2
6 8 -0.20 165 14.89 255 626 4.03 / 346.20 2 3
Average= 3.85
(KJ/cycle)

Cycle 88 GMT 2/ 5/2022 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 29 14.86 412 178 0.18 / 338.37 3 3
2 7 2010.68 53 14.70 3050 2376 2.55 / 340.75 2 2
3 13 1008.44 20 14.69 1714 504 3.06 / 341.25 2 4
4 13 294.28 20 14.86 708 210 3.27 / 341.46 2 3
5 13 65.60 20 14.92 354 106 3.37 / 341.57 2 3
6 8 0.60 165 14.89 246 604 3.98 / 342.17 2 3
Average= 3.84
(KJ/cycle)

Cycle 87 GMT 22/ 4/2022 19:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 29 14.86 416 179 0.18 / 334.35 3 3
2 7 2006.96 53 14.71 3036 2367 2.55 / 336.72 2 2
3 13 1012.56 20 14.70 1736 510 3.06 / 337.23 2 3
4 13 402.96 20 14.83 877 260 3.32 / 337.49 2 3
5 13 51.44 20 14.93 330 99 3.42 / 337.59 2 2
6 8 -0.68 165 14.90 247 607 4.02 / 338.20 2 4
Average= 3.84
(KJ/cycle)

Cycle 86 GMT 12/ 4/2022 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 14.89 404 174 0.17 / 330.30 3 3
2 7 2010.20 53 14.72 3055 2383 2.56 / 332.68 2 2
3 13 997.76 20 14.71 1716 505 3.06 / 333.19 2 4
4 13 397.12 20 14.84 873 259 3.32 / 333.45 2 3
5 13 54.16 20 14.93 343 102 3.42 / 333.55 2 3
6 8 -0.24 165 14.91 253 622 4.05 / 334.17 2 3
Average= 3.84
(KJ/cycle)

Cycle 85 GMT 3/ 4/2022 0:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 29 14.88 421 182 0.18 / 326.37 3 3
2 7 2004.72 53 14.71 3036 2367 2.55 / 328.74 2 2
3 13 888.92 20 14.72 1559 459 3.01 / 329.20 2 3
4 13 320.80 20 14.85 749 222 3.23 / 329.42 2 3
5 13 45.12 20 14.92 326 97 3.33 / 329.52 2 3
6 8 0.52 165 14.90 247 607 3.93 / 330.13 2 3
Average= 3.84
(KJ/cycle)

Cycle 84 GMT 24/ 3/2022 2:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.87 425 183 0.18 / 322.32 3 3
2 7 2007.44 53 14.73 3050 2381 2.56 / 324.70 2 2
3 13 1004.32 20 14.70 1724 507 3.07 / 325.20 2 3
4 13 400.64 20 14.84 872 259 3.33 / 325.46 2 3
5 13 52.52 20 14.93 336 100 3.43 / 325.56 2 3
6 8 0.52 165 14.90 256 629 4.06 / 326.19 3 3
Average= 3.84
(KJ/cycle)

Cycle 83 GMT 14/ 3/2022 5: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 14.89 422 182 0.18 / 318.22 3 3
2 7 2008.16 53 14.70 3067 2389 2.57 / 320.61 2 2
3 13 1022.52 20 14.69 1754 515 3.09 / 321.12 2 5
4 13 412.08 20 14.83 902 268 3.35 / 321.39 2 3
5 13 49.72 20 14.92 339 101 3.46 / 321.49 2 3
6 8 -0.40 165 14.90 260 639 4.09 / 322.13 2 3
Average= 3.83
(KJ/cycle)

Cycle 82 GMT 4/ 3/2022 7:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 29 14.89 424 183 0.18 / 314.19 3 3
2 7 2009.84 53 14.72 3066 2392 2.58 / 316.59 2 2
3 13 1010.20 20 14.70 1748 514 3.09 / 317.10 2 5
4 13 287.40 20 14.88 714 212 3.30 / 317.31 2 3
5 13 35.20 20 14.95 308 92 3.39 / 317.40 2 3
6 8 0.20 165 14.92 257 633 4.03 / 318.04 2 4
Average= 3.83
(KJ/cycle)

Cycle 81 GMT 22/ 2/2022 10: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 29 14.90 418 181 0.18 / 310.20 3 3
2 7 2004.08 53 14.72 3060 2387 2.57 / 312.58 2 2
3 13 891.84 20 14.73 1572 463 3.03 / 313.05 2 4
4 13 327.88 20 14.87 768 228 3.26 / 313.27 2 3
5 13 36.64 20 14.95 306 91 3.35 / 313.37 2 3
6 8 0.24 165 14.91 262 645 4.00 / 314.01 2 4
Average= 3.83
(KJ/cycle)

Cycle 80 GMT 12/ 2/2022 12:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 29 14.88 433 187 0.19 / 306.18 3 3
2 7 2003.80 53 14.72 3044 2375 2.56 / 308.55 2 2
3 13 1011.44 20 14.71 1745 513 3.08 / 309.07 2 5
4 13 289.96 20 14.89 717 214 3.29 / 309.28 2 3
5 13 33.24 20 14.95 316 94 3.38 / 309.38 2 3
6 8 -0.64 165 14.92 260 640 4.02 / 310.02 2 4
Average= 3.83
(KJ/cycle)

Cycle 79 GMT 2/ 2/2022 14:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 14.89 435 181 0.18 / 302.15 3 3
2 7 2009.40 53 14.72 3053 2382 2.56 / 304.53 2 2
3 13 1021.12 20 14.70 1753 515 3.08 / 305.05 2 5
4 13 292.52 20 14.89 712 212 3.29 / 305.26 2 3
5 13 32.36 20 14.95 309 92 3.38 / 305.35 2 2
6 8 -0.60 165 14.92 260 640 4.02 / 305.99 2 3
Average= 3.82
(KJ/cycle)

Cycle 78 GMT 23/ 1/2022 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.90 427 178 0.18 / 298.17 3 3
2 7 2003.92 52 14.73 3047 2334 2.51 / 300.50 2 2
3 13 1014.80 20 14.71 1759 517 3.03 / 301.02 2 5
4 13 288.24 20 14.89 715 213 3.24 / 301.23 2 3
5 13 59.44 20 14.96 360 108 3.35 / 301.34 2 3
6 8 0.80 165 14.92 255 628 3.98 / 301.97 2 3
Average= 3.82
(KJ/cycle)

Cycle 77 GMT 13/ 1/2022 19:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 28 14.91 428 179 0.18 / 294.10 3 3
2 7 2009.20 53 14.72 3041 2372 2.55 / 296.47 2 2
3 13 1006.80 20 14.71 1741 512 3.06 / 296.98 2 3
4 13 397.96 20 14.85 893 265 3.33 / 297.25 2 3
5 13 42.60 20 14.96 330 99 3.43 / 297.35 2 3
6 8 0.20 165 14.94 262 646 4.07 / 297.99 2 3
Average= 3.82
(KJ/cycle)

Cycle 76 GMT 3/ 1/2022 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 28 14.91 419 175 0.17 / 290.08 3 3
2 7 2008.28 53 14.74 3069 2398 2.57 / 292.47 2 2
3 13 1003.84 20 14.72 1734 510 3.08 / 292.98 2 3
4 13 289.44 20 14.91 731 218 3.30 / 293.20 2 3
5 13 30.60 20 14.97 306 92 3.39 / 293.29 2 3
6 8 0.16 165 14.95 253 624 4.02 / 293.92 2 3
Average= 3.82
(KJ/cycle)

Cycle 75 GMT 25/12/2021 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 14.93 428 179 0.18 / 286.03 3 3
2 7 2002.96 53 14.73 3034 2369 2.55 / 288.40 2 2
3 13 1001.36 20 14.73 1726 508 3.06 / 288.91 2 6
4 13 391.08 20 14.87 875 260 3.32 / 289.17 2 3
5 13 41.88 20 14.96 327 98 3.41 / 289.27 2 2
6 8 0.64 165 14.94 257 634 4.05 / 289.90 2 3
Average= 3.81
(KJ/cycle)

Cycle 74 GMT 15/12/2021 3:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 14.94 418 175 0.17 / 282.03 3 3
2 7 2009.16 53 14.74 3040 2375 2.55 / 284.40 2 2
3 13 1012.76 20 14.73 1749 515 3.07 / 284.92 2 5
4 13 284.44 20 14.92 714 213 3.28 / 285.13 2 3
5 13 29.92 20 14.99 309 93 3.37 / 285.22 2 2
6 8 0.04 165 14.96 255 629 4.00 / 285.85 2 3
Average= 3.81
(KJ/cycle)

Cycle 73 GMT 5/12/2021 5:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.94 430 180 0.18 / 278.01 3 3
2 7 2008.08 53 14.74 3058 2389 2.57 / 280.40 2 2
3 13 1010.12 20 14.73 1744 514 3.08 / 280.92 2 5
4 13 283.12 20 14.92 707 211 3.29 / 281.13 2 3
5 13 25.76 20 14.99 298 89 3.38 / 281.22 2 3
6 8 0.44 165 14.97 258 637 4.02 / 281.85 2 3
Average= 3.81
(KJ/cycle)

Cycle 72 GMT 25/11/2021 8:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 28 14.94 431 180 0.18 / 273.95 2 3
2 7 2011.76 53 14.73 3052 2383 2.56 / 276.33 2 2
3 13 1004.76 20 14.74 1731 510 3.07 / 276.84 2 6
4 13 384.16 20 14.89 871 259 3.33 / 277.10 2 3
5 13 20.64 20 14.99 302 91 3.42 / 277.19 2 2
6 8 0.36 165 14.97 261 645 4.07 / 277.83 2 3
Average= 3.81
(KJ/cycle)

Cycle 71 GMT 15/11/2021 11: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 28 14.94 425 178 0.18 / 269.93 3 3
2 7 2007.40 54 14.75 3038 2420 2.60 / 272.35 2 2
3 13 892.68 20 14.77 1588 469 3.07 / 272.82 2 6
4 13 301.00 20 14.91 740 221 3.29 / 273.04 2 3
5 13 25.00 20 15.00 297 89 3.38 / 273.13 2 2
6 8 0.04 165 14.96 258 637 4.01 / 273.77 2 3
Average= 3.80
(KJ/cycle)

Cycle 70 GMT 5/11/2021 13:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 28 14.94 431 180 0.18 / 265.91 2 3
2 7 2008.80 53 14.73 3056 2386 2.57 / 268.29 2 2
3 13 1014.60 20 14.74 1755 517 3.08 / 268.81 2 3
4 13 292.40 20 14.93 724 216 3.30 / 269.03 2 3
5 13 26.84 20 15.00 305 91 3.39 / 269.12 2 3
6 8 0.28 165 14.97 257 635 4.03 / 269.75 2 3
Average= 3.80
(KJ/cycle)

Cycle 69 GMT 26/10/2021 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 28 14.95 448 188 0.19 / 262.07 3 3
2 7 2003.64 52 14.74 3041 2331 2.52 / 264.40 2 2
3 13 898.48 20 14.77 1583 468 2.99 / 264.87 2 5
4 13 314.40 20 14.92 755 225 3.21 / 265.09 2 4
5 8 -0.28 165 14.98 257 635 3.85 / 265.73 2 2
Average= 3.80
(KJ/cycle)

Cycle 68 GMT 16/10/2021 18:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 28 14.94 415 174 0.17 / 258.14 2 3
2 7 2003.96 53 14.74 3046 2380 2.55 / 260.52 2 2
3 13 1008.48 20 14.74 1744 514 3.07 / 261.04 2 5
4 13 265.72 20 14.94 680 203 3.27 / 261.24 2 3
5 8 -0.40 165 15.00 258 639 3.91 / 261.88 2 3
Average= 3.80
(KJ/cycle)

Cycle 67 GMT 6/10/2021 20:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 28 14.96 445 186 0.19 / 254.24 2 3
2 7 2007.44 53 14.76 3045 2382 2.57 / 256.62 2 2
3 13 1007.00 20 14.75 1735 512 3.08 / 257.13 2 3
4 13 277.48 20 14.94 706 211 3.29 / 257.34 2 3
5 8 -0.64 165 14.98 255 630 3.92 / 257.97 2 2
Average= 3.79
(KJ/cycle)

Cycle 66 GMT 26/ 9/2021 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 28 14.95 447 187 0.19 / 250.34 2 3
2 7 2004.12 53 14.76 3041 2379 2.57 / 252.71 2 2
3 13 996.92 20 14.75 1717 507 3.07 / 253.22 2 3
4 13 261.04 20 14.96 668 200 3.27 / 253.42 2 3
5 8 0.76 165 14.99 254 628 3.90 / 254.05 2 3
Average= 3.79
(KJ/cycle)

Cycle 65 GMT 17/ 9/2021 1:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.36 28 14.97 445 187 0.19 / 246.41 2 3
2 7 2008.48 52 14.75 3041 2332 2.52 / 248.74 2 2
3 13 998.08 20 14.77 1726 510 3.03 / 249.25 2 5
4 13 387.12 20 14.91 873 260 3.29 / 249.51 2 3
5 8 0.00 165 14.99 259 641 3.93 / 250.15 2 3
Average= 3.79
(KJ/cycle)

Cycle 64 GMT 7/ 9/2021 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 29 14.96 419 182 0.18 / 242.48 2 3
2 7 2007.44 53 14.75 3044 2380 2.56 / 244.86 2 2
3 13 1006.36 20 14.75 1733 511 3.07 / 245.37 2 4
4 13 283.20 20 14.95 709 212 3.28 / 245.59 2 3
5 8 0.08 165 15.00 256 634 3.92 / 246.22 2 2
Average= 3.79
(KJ/cycle)

Cycle 63 GMT 28/ 8/2021 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 29 14.97 426 185 0.18 / 238.52 2 3
2 7 2005.60 53 14.75 3030 2369 2.55 / 240.89 2 2
3 13 1008.16 20 14.75 1732 511 3.06 / 241.40 2 6
4 13 403.44 20 14.91 884 264 3.33 / 241.67 2 3
5 8 0.16 165 14.99 256 633 3.96 / 242.30 2 3
Average= 3.79
(KJ/cycle)

Cycle 62 GMT 18/ 8/2021 9:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 28 14.98 455 191 0.19 / 234.68 2 3
2 7 2002.80 53 14.75 3019 2360 2.55 / 237.04 2 2
3 13 894.52 20 14.80 1559 461 3.01 / 237.50 2 5
4 13 316.16 20 14.95 749 224 3.24 / 237.72 2 3
5 8 0.16 165 15.01 249 617 3.85 / 238.34 2 3
Average= 3.78
(KJ/cycle)

Cycle 61 GMT 8/ 8/2021 11:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 28 14.97 449 188 0.19 / 230.75 3 3
2 7 2003.16 53 14.76 3041 2379 2.57 / 233.13 2 2
3 13 1012.24 20 14.76 1744 515 3.08 / 233.65 2 3
4 13 290.68 20 14.95 710 212 3.29 / 233.86 2 3
5 8 -0.08 165 15.02 253 627 3.92 / 234.49 2 3
Average= 3.78
(KJ/cycle)

Cycle 60 GMT 29/ 7/2021 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 28 14.97 456 191 0.19 / 226.76 3 3
2 7 2006.04 53 14.76 3051 2387 2.58 / 229.14 2 2
3 13 1016.68 20 14.76 1753 517 3.10 / 229.66 2 4
4 13 387.00 20 14.93 867 259 3.35 / 229.92 2 3
5 8 -0.28 165 15.00 261 646 4.00 / 230.56 2 3
Average= 3.78
(KJ/cycle)

Cycle 59 GMT 19/ 7/2021 16:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 14.98 442 185 0.19 / 222.64 3 3
2 7 2003.84 53 14.77 3040 2380 2.57 / 225.02 2 2
3 13 996.52 20 14.78 1721 509 3.07 / 225.52 2 5
4 13 391.40 20 14.93 876 262 3.34 / 225.79 2 3
5 8 0.72 165 15.00 266 658 3.99 / 226.44 2 3
6 14 0.72 30 14.98 269 121 4.11 / 226.56 2 3
Average= 3.78
(KJ/cycle)

Cycle 58 GMT 9/ 7/2021 19: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 28 14.99 430 180 0.18 / 218.63 3 3
2 7 2004.52 53 14.77 3042 2381 2.56 / 221.01 2 2
3 13 993.40 20 14.78 1720 508 3.07 / 221.52 2 4
4 13 390.96 20 14.93 873 261 3.33 / 221.78 2 3
5 8 0.60 165 15.01 270 669 4.00 / 222.45 2 3
Average= 3.77
(KJ/cycle)

Cycle 57 GMT 29/ 6/2021 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 28 14.99 436 183 0.18 / 214.64 3 3
2 7 2008.00 53 14.75 3041 2377 2.56 / 217.01 2 2
3 13 997.72 20 14.79 1726 511 3.07 / 217.52 2 3
4 13 384.24 20 14.94 860 257 3.33 / 217.78 2 3
5 8 0.64 165 15.01 270 669 4.00 / 218.45 2 3
Average= 3.77
(KJ/cycle)

Cycle 56 GMT 20/ 6/2021 0:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 28 14.98 464 195 0.19 / 210.63 2 3
2 7 2006.04 53 14.77 3045 2384 2.58 / 213.01 2 2
3 13 1009.04 20 14.79 1747 517 3.10 / 213.53 2 3
4 13 391.92 20 14.93 879 262 3.36 / 213.79 2 3
5 8 -0.12 165 15.02 267 662 4.02 / 214.45 2 3
Average= 3.76
(KJ/cycle)

Cycle 55 GMT 10/ 6/2021 2:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 28 15.00 431 181 0.18 / 206.60 3 3
2 7 2003.32 53 14.78 3038 2380 2.56 / 208.98 2 2
3 13 1007.52 20 14.79 1746 516 3.08 / 209.49 2 3
4 13 398.68 20 14.94 893 267 3.34 / 209.76 2 3
5 8 0.28 165 15.02 272 674 4.02 / 210.43 2 2
Average= 3.76
(KJ/cycle)

Cycle 54 GMT 31/ 5/2021 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 28 14.99 426 179 0.18 / 202.68 3 3
2 7 2005.32 53 14.78 3036 2378 2.56 / 205.06 2 2
3 13 897.28 20 14.83 1588 471 3.03 / 205.53 2 4
4 13 317.48 20 14.97 765 229 3.26 / 205.76 2 3
5 8 -0.04 165 15.02 264 654 3.91 / 206.42 2 3
Average= 3.75
(KJ/cycle)

Cycle 53 GMT 21/ 5/2021 7:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 28 15.00 447 188 0.19 / 198.81 3 3
2 7 2006.60 52 14.77 3029 2326 2.51 / 201.14 2 2
3 13 1001.36 20 14.79 1728 511 3.03 / 201.65 2 3
4 13 273.96 20 14.98 704 211 3.24 / 201.86 2 3
5 8 -0.08 165 15.03 261 647 3.88 / 202.51 2 3
Average= 3.75
(KJ/cycle)

Cycle 52 GMT 11/ 5/2021 9:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 28 14.98 434 182 0.18 / 194.75 3 3
2 7 2004.96 53 14.78 3043 2384 2.57 / 197.13 2 2
3 13 894.08 20 14.82 1585 470 3.04 / 197.60 2 3
4 13 313.04 20 14.98 765 229 3.26 / 197.83 2 3
5 8 0.64 165 15.03 270 670 3.93 / 198.50 2 3
6 14 0.64 30 15.01 272 122 4.06 / 198.62 2 3
Average= 3.75
(KJ/cycle)

Cycle 51 GMT 1/ 5/2021 12:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 28 15.00 443 186 0.19 / 190.62 3 3
2 7 2010.12 53 14.78 3054 2392 2.58 / 193.01 2 2
3 13 1001.92 20 14.80 1738 514 3.09 / 193.52 2 3
4 13 389.44 20 14.96 875 262 3.35 / 193.78 2 3
5 13 39.16 20 15.05 330 99 3.45 / 193.88 2 2
6 8 -0.32 165 15.03 275 682 4.14 / 194.56 2 3
Average= 3.74
(KJ/cycle)

Cycle 50 GMT 21/ 4/2021 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 29 15.00 434 189 0.19 / 186.56 3 3
2 7 2002.64 52 14.77 3050 2343 2.53 / 188.90 2 2
3 13 1012.48 20 14.80 1761 521 3.05 / 189.42 2 3
4 13 292.84 20 14.99 734 220 3.27 / 189.64 2 4
5 13 27.44 20 15.05 316 95 3.37 / 189.74 2 2
6 8 0.08 165 15.03 278 689 4.06 / 190.43 2 3
Average= 3.73
(KJ/cycle)

Cycle 49 GMT 11/ 4/2021 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 28 15.01 454 191 0.19 / 182.53 3 3
2 7 2003.60 53 14.78 3041 2382 2.57 / 184.92 2 2
3 13 1008.80 20 14.80 1746 517 3.09 / 185.43 2 6
4 13 396.48 20 14.95 889 266 3.36 / 185.70 2 3
5 8 -0.08 165 15.04 271 673 4.03 / 186.37 2 3
Average= 3.73
(KJ/cycle)

Cycle 48 GMT 1/ 4/2021 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 28 15.02 430 181 0.18 / 178.58 3 3
2 7 2003.16 53 14.79 3035 2379 2.56 / 180.96 2 2
3 13 902.76 20 14.83 1611 478 3.04 / 181.44 2 5
4 13 320.16 20 14.99 779 234 3.27 / 181.67 2 3
5 8 0.20 165 15.03 271 672 3.94 / 182.34 2 3
Average= 3.72
(KJ/cycle)

Cycle 47 GMT 22/ 3/2021 22:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 28 15.00 432 181 0.18 / 174.61 3 3
2 7 2002.36 53 14.78 3038 2380 2.56 / 176.99 2 2
3 13 1000.84 20 14.81 1755 520 3.08 / 177.51 2 5
4 13 269.92 20 15.01 698 210 3.29 / 177.72 2 3
5 8 0.64 165 15.04 273 677 3.97 / 178.40 2 3
Average= 3.72
(KJ/cycle)

Cycle 46 GMT 13/ 3/2021 0:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 28 15.01 446 187 0.19 / 170.55 3 3
2 7 2002.64 52 14.79 3063 2356 2.54 / 172.91 2 2
3 13 1000.96 20 14.81 1754 520 3.06 / 173.43 2 5
4 13 278.56 20 15.01 723 217 3.28 / 173.64 2 3
5 13 25.84 20 15.07 316 95 3.37 / 173.74 2 2
6 8 -0.44 165 15.04 280 695 4.07 / 174.43 2 2
Average= 3.71
(KJ/cycle)

Cycle 45 GMT 3/ 3/2021 2:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.01 441 185 0.19 / 166.36 3 3
2 7 2005.44 53 14.79 3073 2409 2.59 / 168.77 2 2
3 13 1003.24 20 14.81 1766 523 3.12 / 169.29 2 5
4 13 384.44 20 14.98 875 262 3.38 / 169.55 2 3
5 13 19.72 20 15.07 322 97 3.48 / 169.65 2 3
6 8 -0.04 165 15.05 288 715 4.19 / 170.36 2 3
Average= 3.70
(KJ/cycle)

Cycle 44 GMT 21/ 2/2021 5:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.60 28 15.04 479 202 0.20 / 162.29 3 3
2 7 2003.40 52 14.80 3057 2353 2.55 / 164.64 2 2
3 13 996.88 20 14.83 1749 519 3.07 / 165.16 2 5
4 13 266.12 20 15.02 717 215 3.29 / 165.37 2 3
5 13 24.52 20 15.08 318 96 3.38 / 165.47 2 3
6 8 -0.28 165 15.05 282 700 4.08 / 166.17 2 3
Average= 3.69
(KJ/cycle)

Cycle 43 GMT 11/ 2/2021 7:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 28 15.03 385 162 0.16 / 158.30 3 3
2 7 2009.48 53 14.80 3059 2399 2.56 / 160.69 2 2
3 13 1000.88 20 14.84 1699 504 3.07 / 161.20 2 5
4 13 378.64 20 15.00 819 246 3.31 / 161.44 2 3
5 8 0.08 165 15.07 258 642 3.95 / 162.09 2 3
Average= 3.68
(KJ/cycle)

Cycle 42 GMT 1/ 2/2021 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 28 15.06 404 170 0.17 / 154.37 3 3
2 7 2003.08 53 14.79 3045 2387 2.56 / 156.76 2 2
3 13 1003.04 20 14.84 1698 504 3.06 / 157.26 2 3
4 13 379.48 20 15.00 815 244 3.31 / 157.51 2 3
5 13 21.72 20 15.09 259 78 3.38 / 157.58 2 2
6 8 0.72 165 15.07 221 550 3.93 / 158.13 2 3
Average= 3.68
(KJ/cycle)

Cycle 41 GMT 22/ 1/2021 12:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 15.05 384 162 0.16 / 150.57 3 3
2 7 2003.24 52 14.80 3066 2360 2.52 / 152.93 2 2
3 13 1001.80 20 14.85 1701 505 3.03 / 153.44 2 5
4 13 272.16 20 15.04 658 198 3.22 / 153.64 2 3
5 8 0.16 165 15.08 226 562 3.79 / 154.20 2 3
Average= 3.67
(KJ/cycle)

Cycle 40 GMT 12/ 1/2021 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 28 15.07 375 158 0.16 / 146.68 3 3
2 7 2003.24 53 14.80 3056 2397 2.56 / 149.07 2 2
3 13 1000.92 20 14.85 1704 506 3.06 / 149.58 2 4
4 13 266.60 20 15.04 648 195 3.26 / 149.77 2 3
5 13 20.04 20 15.11 259 78 3.33 / 149.85 2 2
6 8 -0.20 165 15.08 225 560 3.89 / 150.41 2 4
Average= 3.67
(KJ/cycle)

Cycle 39 GMT 2/ 1/2021 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 28 15.08 374 158 0.16 / 142.92 3 3
2 7 2006.68 53 14.80 3036 2381 2.54 / 145.30 2 2
3 13 887.24 20 14.89 1537 458 3.00 / 145.76 2 4
4 13 309.72 20 15.03 711 214 3.21 / 145.97 2 3
5 8 0.32 165 15.09 220 548 3.76 / 146.52 2 2
Average= 3.66
(KJ/cycle)

Cycle 38 GMT 23/12/2020 19:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 28 15.06 376 159 0.16 / 139.15 3 3
2 7 2009.24 52 14.82 3056 2355 2.51 / 141.50 2 2
3 13 1016.52 20 14.85 1718 510 3.02 / 142.01 2 5
4 13 279.48 20 15.04 661 199 3.22 / 142.21 2 3
5 8 0.84 165 15.10 221 551 3.77 / 142.76 2 3
Average= 3.66
(KJ/cycle)

Cycle 37 GMT 13/12/2020 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 28 15.06 376 159 0.16 / 135.33 3 3
2 7 2002.96 53 14.80 3049 2392 2.55 / 137.72 2 2
3 13 1010.32 20 14.84 1713 508 3.06 / 138.23 2 5
4 13 271.32 20 15.05 651 196 3.25 / 138.43 2 3
5 8 0.48 165 15.10 224 558 3.81 / 138.99 2 3
Average= 3.66
(KJ/cycle)

Cycle 36 GMT 4/12/2020 0:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 28 15.08 409 173 0.17 / 131.46 2 3
2 7 2004.16 53 14.82 3058 2402 2.57 / 133.87 2 2
3 13 986.12 20 14.86 1677 498 3.07 / 134.36 2 5
4 13 371.40 20 15.02 805 242 3.31 / 134.61 2 3
5 8 0.48 165 15.09 228 568 3.88 / 135.17 2 3
Average= 3.65
(KJ/cycle)

Cycle 35 GMT 24/11/2020 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 28 15.07 388 164 0.16 / 127.61 2 3
2 7 2003.92 52 14.82 3045 2347 2.51 / 129.95 2 2
3 13 997.56 20 14.86 1689 502 3.01 / 130.46 2 6
4 13 483.20 20 14.99 957 287 3.30 / 130.74 2 3
5 8 0.56 165 15.10 220 548 3.85 / 131.29 2 3
Average= 3.65
(KJ/cycle)

Cycle 34 GMT 14/11/2020 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.56 28 15.08 417 176 0.18 / 123.82 2 3
2 7 2004.00 53 14.84 3050 2399 2.57 / 126.22 2 2
3 13 877.76 20 14.91 1526 455 3.03 / 126.67 2 3
4 13 295.80 20 15.05 694 209 3.24 / 126.88 2 3
5 8 0.52 165 15.11 225 561 3.80 / 127.44 2 3
Average= 3.64
(KJ/cycle)

Cycle 33 GMT 4/11/2020 7:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 28 15.08 415 175 0.18 / 120.01 2 3
2 7 2001.96 53 14.83 3052 2399 2.57 / 122.40 2 2
3 13 989.16 20 14.87 1678 499 3.07 / 122.90 2 4
4 13 244.32 20 15.07 612 184 3.26 / 123.09 2 3
5 8 -0.28 165 15.11 223 556 3.81 / 123.64 2 2
Average= 3.64
(KJ/cycle)

Cycle 32 GMT 25/10/2020 9:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 28 15.08 406 171 0.17 / 116.12 2 3
2 7 2004.36 53 14.83 3060 2405 2.58 / 118.53 2 2
3 13 973.72 20 14.88 1657 493 3.07 / 119.02 2 5
4 13 361.96 20 15.02 795 239 3.31 / 119.26 2 3
5 8 -0.24 165 15.10 230 573 3.88 / 119.83 2 3
Average= 3.63
(KJ/cycle)

Cycle 31 GMT 15/10/2020 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 28 15.09 413 175 0.17 / 112.31 2 3
2 7 2005.84 53 14.83 3043 2392 2.57 / 114.71 2 2
3 13 977.16 20 14.88 1666 496 3.06 / 115.20 2 4
4 13 236.88 20 15.08 602 182 3.24 / 115.38 2 3
5 8 -0.72 165 15.11 227 566 3.81 / 115.95 2 3
Average= 3.62
(KJ/cycle)

Cycle 30 GMT 5/10/2020 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 28 15.09 420 177 0.18 / 108.50 2 3
2 7 2002.12 53 14.84 3039 2390 2.57 / 110.89 2 2
3 13 978.40 20 14.89 1664 496 3.06 / 111.39 2 4
4 13 241.00 20 15.08 605 182 3.25 / 111.57 2 3
5 8 -0.20 165 15.11 229 571 3.82 / 112.14 2 3
Average= 3.62
(KJ/cycle)

Cycle 29 GMT 25/ 9/2020 17: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 27 15.09 414 169 0.17 / 104.73 2 3
2 7 2006.68 52 14.84 3056 2358 2.53 / 107.09 2 2
3 13 879.56 20 14.92 1527 456 2.98 / 107.55 2 5
4 13 290.56 20 15.06 686 207 3.19 / 107.75 2 3
5 8 -0.44 165 15.12 228 569 3.76 / 108.32 2 2
Average= 3.61
(KJ/cycle)

Cycle 28 GMT 15/ 9/2020 19:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 27 15.09 391 159 0.16 / 100.91 2 3
2 7 2005.20 53 14.84 3040 2391 2.55 / 103.30 2 2
3 13 998.64 20 14.89 1682 501 3.05 / 103.80 2 5
4 13 249.08 20 15.08 616 186 3.24 / 103.99 2 3
5 8 0.60 165 15.12 231 576 3.81 / 104.56 2 3
Average= 3.61
(KJ/cycle)

Cycle 27 GMT 5/ 9/2020 21:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 27 15.10 413 168 0.17 / 97.14 2 3
2 7 2003.72 53 14.84 3036 2388 2.56 / 99.53 2 2
3 13 877.40 20 14.92 1522 454 3.01 / 99.98 2 4
4 13 280.56 20 15.07 667 201 3.21 / 100.19 2 3
5 8 0.68 165 15.11 227 566 3.78 / 100.75 2 3
Average= 3.60
(KJ/cycle)

Cycle 26 GMT 27/ 8/2020 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 27 15.08 421 171 0.17 / 93.35 2 3
2 7 2008.08 53 14.85 3041 2393 2.56 / 95.74 2 2
3 13 979.56 20 14.90 1660 495 3.06 / 96.23 2 6
4 13 232.64 20 15.10 591 178 3.24 / 96.41 2 3
5 8 0.48 165 15.13 225 562 3.80 / 96.97 2 3
Average= 3.59
(KJ/cycle)

Cycle 25 GMT 17/ 8/2020 2:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 27 15.10 414 169 0.17 / 89.52 2 3
2 7 2007.20 53 14.84 3045 2395 2.56 / 91.92 2 2
3 13 985.76 20 14.89 1673 498 3.06 / 92.41 2 4
4 13 243.20 20 15.09 610 184 3.25 / 92.60 2 3
5 8 -0.68 165 15.12 231 576 3.82 / 93.17 2 3
Average= 3.58
(KJ/cycle)

Cycle 24 GMT 7/ 8/2020 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.96 27 15.10 412 168 0.17 / 85.67 2 3
2 7 2003.60 53 14.85 3040 2393 2.56 / 88.06 2 2
3 13 964.96 20 14.91 1638 488 3.05 / 88.55 2 4
4 13 331.08 20 15.06 744 224 3.27 / 88.77 2 3
5 8 -0.08 165 15.13 232 579 3.85 / 89.35 2 3
Average= 3.57
(KJ/cycle)

Cycle 23 GMT 28/ 7/2020 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 27 15.10 417 170 0.17 / 81.87 2 3
2 7 2004.44 53 14.86 3047 2400 2.57 / 84.27 2 2
3 13 974.88 20 14.91 1656 494 3.06 / 84.77 2 4
4 13 233.08 20 15.11 593 179 3.24 / 84.95 2 3
5 8 -0.20 165 15.13 222 554 3.80 / 85.50 2 2
Average= 3.56
(KJ/cycle)

Cycle 22 GMT 18/ 7/2020 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 27 15.10 404 165 0.16 / 78.08 2 3
2 7 2002.12 53 14.86 3049 2401 2.57 / 80.48 2 2
3 13 881.16 20 14.93 1524 455 3.02 / 80.94 2 5
4 13 282.28 20 15.08 669 202 3.22 / 81.14 2 3
5 8 0.76 165 15.13 226 564 3.79 / 81.70 2 2
Average= 3.55
(KJ/cycle)

Cycle 21 GMT 8/ 7/2020 12:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 27 15.11 400 163 0.16 / 74.26 2 3
2 7 2002.12 53 14.86 3052 2404 2.57 / 76.66 2 2
3 13 990.04 20 14.91 1680 501 3.07 / 77.16 2 3
4 13 243.80 20 15.10 614 185 3.25 / 77.35 2 3
5 8 0.20 165 15.14 227 567 3.82 / 77.92 2 5
Average= 3.54
(KJ/cycle)

Cycle 20 GMT 28/ 6/2020 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 27 15.12 400 163 0.16 / 70.48 2 3
2 7 2002.04 53 14.87 3045 2400 2.56 / 72.88 2 2
3 13 865.28 20 14.95 1506 450 3.01 / 73.33 2 5
4 13 273.84 20 15.10 659 199 3.21 / 73.53 2 3
5 8 0.08 165 15.14 225 562 3.77 / 74.10 2 3
Average= 3.53
(KJ/cycle)

Cycle 19 GMT 18/ 6/2020 16:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 27 15.12 411 168 0.17 / 66.64 3 3
2 7 2003.28 53 14.87 3045 2400 2.57 / 69.04 2 2
3 13 965.00 20 14.92 1639 489 3.06 / 69.53 2 3
4 13 342.08 20 15.08 764 230 3.29 / 69.76 2 3
5 8 0.16 165 15.14 226 565 3.85 / 70.32 2 3
Average= 3.52
(KJ/cycle)

Cycle 18 GMT 8/ 6/2020 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 27 15.12 414 169 0.17 / 62.81 2 3
2 7 2002.24 52 14.87 3035 2347 2.52 / 65.16 2 2
3 13 862.28 20 14.96 1503 450 2.97 / 65.61 2 3
4 13 257.68 20 15.11 639 193 3.16 / 65.80 2 3
5 8 -0.36 165 15.15 226 565 3.72 / 66.37 2 3
6 14 -0.36 30 15.13 229 104 3.83 / 66.47 2 3
Average= 3.50
(KJ/cycle)

Cycle 17 GMT 29/ 5/2020 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 27 15.12 382 156 0.16 / 59.04 3 3
2 7 2006.12 53 14.88 3040 2397 2.55 / 61.44 2 2
3 13 856.68 20 14.96 1492 446 3.00 / 61.89 2 2
4 13 252.52 20 15.11 625 189 3.19 / 62.08 2 3
5 8 -0.08 165 15.15 226 565 3.75 / 62.64 2 3
Average= 3.48
(KJ/cycle)

Cycle 16 GMT 19/ 5/2020 23:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 27 15.12 385 157 0.16 / 55.26 2 3
2 7 2007.00 53 14.87 3039 2395 2.55 / 57.66 2 2
3 13 982.48 20 14.94 1664 497 3.05 / 58.16 2 2
4 13 226.68 20 15.11 587 177 3.23 / 58.33 2 3
5 8 0.56 165 15.15 222 555 3.78 / 58.89 2 4
Average= 3.46
(KJ/cycle)

Cycle 15 GMT 10/ 5/2020 2:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 27 15.13 381 156 0.16 / 51.48 2 3
2 7 2007.52 53 14.88 3052 2407 2.56 / 53.89 2 2
3 13 877.36 20 14.96 1523 456 3.02 / 54.34 2 2
4 13 269.72 20 15.11 653 197 3.22 / 54.54 2 3
5 8 0.08 165 15.15 227 567 3.78 / 55.11 2 3
Average= 3.44
(KJ/cycle)

Cycle 14 GMT 30/ 4/2020 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 27 15.12 412 168 0.17 / 47.70 3 3
2 7 2002.88 53 14.88 3044 2401 2.57 / 50.10 2 2
3 13 969.24 20 14.94 1649 493 3.06 / 50.60 2 2
4 13 225.80 20 15.13 582 176 3.24 / 50.77 2 2
5 8 0.00 165 15.17 220 551 3.79 / 51.32 2 3
Average= 3.42
(KJ/cycle)

Cycle 13 GMT 20/ 4/2020 6:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 27 15.13 404 165 0.17 / 43.92 2 3
2 7 2005.80 53 14.89 3046 2404 2.57 / 46.32 2 2
3 13 860.24 20 14.97 1492 447 3.02 / 46.77 2 2
4 13 262.16 20 15.12 639 193 3.21 / 46.96 2 3
5 8 -0.60 165 15.16 230 575 3.78 / 47.53 2 2
Average= 3.40
(KJ/cycle)

Cycle 12 GMT 10/ 4/2020 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 27 15.14 386 158 0.16 / 40.14 2 3
2 7 2002.84 53 14.89 3036 2396 2.55 / 42.54 2 2
3 13 870.12 20 14.97 1515 454 3.01 / 42.99 2 2
4 13 255.00 20 15.12 633 191 3.20 / 43.18 2 3
5 8 0.04 165 15.16 228 570 3.77 / 43.75 2 2
Average= 3.37
(KJ/cycle)

Cycle 11 GMT 31/ 3/2020 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 27 15.14 409 167 0.17 / 36.32 3 3
2 7 2006.12 53 14.88 3046 2402 2.57 / 38.73 2 2
3 13 989.32 20 14.93 1670 499 3.07 / 39.23 2 2
4 13 238.88 20 15.12 606 183 3.25 / 39.41 2 3
5 8 -0.04 165 15.16 229 573 3.82 / 39.98 2 2
Average= 3.33
(KJ/cycle)

Cycle 10 GMT 21/ 3/2020 13:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 27 15.15 405 166 0.17 / 32.56 3 3
2 7 2006.88 53 14.89 3048 2405 2.57 / 34.96 2 2
3 13 847.44 20 14.98 1482 444 3.02 / 35.41 2 2
4 13 249.72 20 15.14 618 187 3.20 / 35.59 2 3
5 8 -0.28 165 15.17 225 563 3.77 / 36.16 2 2
Average= 3.29
(KJ/cycle)

Cycle 9 GMT 11/ 3/2020 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.08 27 15.14 408 167 0.17 / 28.79 3 3
2 7 2003.20 53 14.90 3034 2396 2.56 / 31.19 2 2
3 13 873.52 20 14.98 1511 453 3.02 / 31.64 2 2
4 13 257.80 20 15.13 631 191 3.21 / 31.83 2 3
5 8 0.16 165 15.17 225 563 3.77 / 32.39 2 3
Average= 3.24
(KJ/cycle)

Cycle 8 GMT 1/ 3/2020 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 27 15.14 401 164 0.16 / 24.96 2 3
2 7 2007.20 54 14.89 3038 2443 2.61 / 27.40 2 2
3 13 852.04 19 14.99 1484 423 3.03 / 27.82 2 2
4 13 255.76 19 15.13 624 179 3.21 / 28.00 2 3
5 13 18.76 19 15.20 250 72 3.28 / 28.07 2 2
6 8 -0.12 165 15.17 219 548 3.83 / 28.62 2 3
Average= 3.18
(KJ/cycle)

Cycle 7 GMT 20/ 2/2020 20:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 27 15.16 391 160 0.16 / 21.20 3 3
2 7 2006.88 53 14.89 3045 2403 2.56 / 23.61 2 2
3 13 840.60 18 15.00 1469 397 2.96 / 24.00 2 2
4 13 249.28 18 15.15 620 169 3.13 / 24.17 2 3
5 13 18.80 18 15.20 250 68 3.20 / 24.24 2 2
6 8 -0.08 165 15.17 221 553 3.75 / 24.79 2 3
Average= 3.10
(KJ/cycle)

Cycle 6 GMT 10/ 2/2020 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 25 15.15 393 149 0.15 / 17.43 2 3
2 10 1004.48 2 15.11 1745 53 0.20 / 17.48 2 2
3 7 2006.48 52 14.91 3031 2350 2.55 / 19.83 2 2
4 13 970.96 18 14.97 1642 442 2.99 / 20.28 2 2
5 13 241.44 18 15.14 601 164 3.16 / 20.44 2 3
6 13 18.40 18 15.19 250 68 3.23 / 20.51 2 2
7 8 -0.08 165 15.18 214 536 3.76 / 21.04 2 2
Average= 3.01
(KJ/cycle)

Cycle 5 GMT 1/ 2/2020 0:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 25 15.17 388 147 0.15 / 13.79 3 3
2 3 1038.48 1 15.16 1813 27 0.17 / 13.82 2 2
3 7 2003.60 52 14.92 3020 2343 2.52 / 16.16 2 2
4 13 863.96 18 15.00 1493 403 2.92 / 16.56 2 2
5 13 276.84 18 15.13 655 178 3.10 / 16.74 2 2
6 8 -0.56 165 15.18 216 541 3.64 / 17.28 2 2
Average= 2.88
(KJ/cycle)

Cycle 4 GMT 22/ 1/2020 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 25 15.17 392 149 0.15 / 10.44 3 3
2 7 1518.36 74 14.83 2333 2560 2.71 / 13.00 2 2
3 13 114.84 18 15.20 401 110 2.82 / 13.11 2 2
4 8 0.12 165 15.19 213 534 3.35 / 13.64 2 3
Average= 2.73
(KJ/cycle)

Cycle 3 GMT 21/ 1/2020 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 25 15.17 398 151 0.15 / 7.03 3 3
2 3 1023.24 1 15.18 1788 27 0.18 / 7.06 2 2
3 7 1522.28 75 14.83 2336 2598 2.78 / 9.66 2 2
4 13 109.56 18 15.19 386 106 2.88 / 9.76 2 2
5 8 0.16 165 15.19 209 524 3.41 / 10.29 2 2
Average= 2.57
(KJ/cycle)

Cycle 2 GMT 20/ 1/2020 3:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 26 15.21 390 154 0.15 / 3.72 2 3
2 3 964.76 -1 15.47 0 0 0.00 / 3.72 2 3
3 7 1509.08 74 14.84 2318 2546 2.70 / 6.26 2 2
4 13 103.36 18 15.20 374 102 2.80 / 6.36 2 2
5 8 0.16 165 15.19 207 519 3.32 / 6.88 2 2
Average= 2.29
(KJ/cycle)

Cycle 1 GMT 19/ 1/2020 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 23 15.41 341 121 0.12 / 1.14 3 3
2 10 1011.36 3 15.20 1729 79 0.20 / 1.22 2 2
3 7 984.84 75 15.04 1609 1815 2.01 / 3.04 2 3
4 8 0.00 165 15.25 208 523 2.54 / 3.56 2 2
Average= 1.78
(KJ/cycle)

Cycle 0 GMT 18/ 1/2020 18: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.56 22 15.52 257 88 0.09 / 0.09 3 3
2 7 67.52 74 15.49 270 309 0.40 / 0.40 3 3
3 8 0.24 240 15.45 169 627 1.02 / 1.02 3 10
Average= 1.02
(KJ/cycle)