SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.04 | 30 | 14.86 | 475 | 212 | 0.21 / 792.53 | 3 | 3 |
2 | 7 | 2011.60 | 53 | 14.77 | 3195 | 2501 | 2.71 / 795.03 | 2 | 2 |
3 | 13 | 1018.72 | 21 | 14.74 | 1822 | 564 | 3.28 / 795.59 | 2 | 3 |
4 | 13 | 409.44 | 21 | 14.86 | 942 | 294 | 3.57 / 795.89 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.91 | 282 | 694 | 4.26 / 796.58 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 30 | 14.86 | 444 | 198 | 0.20 / 788.25 | 3 | 3 |
2 | 7 | 2003.40 | 53 | 14.79 | 3184 | 2496 | 2.69 / 790.74 | 2 | 2 |
3 | 13 | 915.68 | 21 | 14.77 | 1683 | 522 | 3.22 / 791.26 | 2 | 3 |
4 | 13 | 344.28 | 21 | 14.88 | 846 | 264 | 3.48 / 791.53 | 2 | 4 |
5 | 13 | 16.28 | 21 | 14.94 | 312 | 98 | 3.58 / 791.63 | 2 | 3 |
6 | 8 | -0.04 | 165 | 14.92 | 281 | 692 | 4.27 / 792.32 | 3 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 30 | 14.86 | 470 | 210 | 0.21 / 783.85 | 3 | 3 |
2 | 7 | 2004.48 | 53 | 14.80 | 3191 | 2503 | 2.71 / 786.35 | 2 | 2 |
3 | 13 | 1157.56 | 21 | 14.71 | 2020 | 624 | 3.34 / 786.97 | 2 | 3 |
4 | 13 | 391.72 | 21 | 14.87 | 918 | 287 | 3.62 / 787.26 | 2 | 3 |
5 | 13 | 18.16 | 21 | 14.95 | 315 | 99 | 3.72 / 787.36 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.91 | 280 | 689 | 4.41 / 788.05 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 30 | 14.86 | 446 | 199 | 0.20 / 779.62 | 3 | 3 |
2 | 7 | 2011.60 | 52 | 14.79 | 3201 | 2462 | 2.66 / 782.08 | 2 | 2 |
3 | 13 | 1024.84 | 21 | 14.74 | 1835 | 568 | 3.23 / 782.65 | 2 | 3 |
4 | 13 | 424.24 | 21 | 14.85 | 963 | 300 | 3.53 / 782.95 | 2 | 3 |
5 | 8 | 0.08 | 165 | 14.91 | 281 | 691 | 4.22 / 783.64 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 30 | 14.85 | 447 | 199 | 0.20 / 775.45 | 3 | 3 |
2 | 7 | 2010.44 | 52 | 14.78 | 3188 | 2450 | 2.65 / 777.90 | 2 | 2 |
3 | 13 | 1027.76 | 21 | 14.75 | 1841 | 570 | 3.22 / 778.47 | 2 | 3 |
4 | 13 | 321.24 | 21 | 14.88 | 800 | 250 | 3.47 / 778.72 | 2 | 3 |
5 | 8 | 0.04 | 165 | 14.92 | 284 | 699 | 4.17 / 779.42 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 30 | 14.86 | 453 | 202 | 0.20 / 771.09 | 3 | 3 |
2 | 7 | 2009.24 | 53 | 14.78 | 3189 | 2498 | 2.70 / 773.59 | 2 | 2 |
3 | 13 | 1013.04 | 21 | 14.75 | 1818 | 563 | 3.26 / 774.15 | 2 | 3 |
4 | 13 | 403.44 | 21 | 14.86 | 945 | 295 | 3.56 / 774.45 | 2 | 4 |
5 | 13 | 17.92 | 21 | 14.94 | 315 | 99 | 3.66 / 774.55 | 2 | 2 |
6 | 8 | 0.04 | 165 | 14.89 | 285 | 700 | 4.36 / 775.25 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.92 | 30 | 14.86 | 477 | 213 | 0.21 / 766.95 | 3 | 3 |
2 | 7 | 2004.00 | 52 | 14.79 | 3194 | 2456 | 2.67 / 769.41 | 2 | 2 |
3 | 13 | 897.80 | 21 | 14.77 | 1662 | 516 | 3.18 / 769.92 | 2 | 3 |
4 | 13 | 334.08 | 21 | 14.89 | 832 | 260 | 3.44 / 770.18 | 2 | 3 |
5 | 8 | 0.16 | 165 | 14.91 | 287 | 706 | 4.15 / 770.89 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.44 | 30 | 14.86 | 473 | 211 | 0.21 / 762.67 | 3 | 3 |
2 | 7 | 2007.40 | 53 | 14.80 | 3194 | 2505 | 2.72 / 765.18 | 2 | 2 |
3 | 13 | 1002.56 | 21 | 14.76 | 1802 | 559 | 3.27 / 765.73 | 2 | 3 |
4 | 13 | 407.20 | 21 | 14.87 | 947 | 296 | 3.57 / 766.03 | 2 | 4 |
5 | 8 | -0.08 | 165 | 14.93 | 288 | 709 | 4.28 / 766.74 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 30 | 14.85 | 479 | 213 | 0.21 / 758.45 | 2 | 3 |
2 | 7 | 2011.44 | 53 | 14.79 | 3204 | 2512 | 2.72 / 760.96 | 2 | 2 |
3 | 13 | 922.72 | 21 | 14.77 | 1697 | 526 | 3.25 / 761.49 | 2 | 3 |
4 | 13 | 343.76 | 21 | 14.88 | 850 | 266 | 3.52 / 761.75 | 2 | 4 |
5 | 8 | 0.16 | 165 | 14.93 | 287 | 707 | 4.22 / 762.46 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.72 | 30 | 14.87 | 476 | 212 | 0.21 / 754.17 | 3 | 3 |
2 | 7 | 2008.92 | 53 | 14.78 | 3198 | 2505 | 2.72 / 756.68 | 2 | 2 |
3 | 13 | 1001.12 | 21 | 14.74 | 1800 | 557 | 3.27 / 757.23 | 2 | 3 |
4 | 13 | 410.80 | 21 | 14.86 | 955 | 298 | 3.57 / 757.53 | 2 | 4 |
5 | 8 | 0.04 | 165 | 14.90 | 287 | 706 | 4.28 / 758.24 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 30 | 14.84 | 450 | 200 | 0.20 / 749.94 | 3 | 3 |
2 | 7 | 2003.64 | 53 | 14.78 | 3187 | 2497 | 2.70 / 752.44 | 2 | 2 |
3 | 13 | 1031.32 | 21 | 14.74 | 1847 | 572 | 3.27 / 753.01 | 2 | 3 |
4 | 13 | 307.24 | 21 | 14.88 | 795 | 248 | 3.52 / 753.26 | 2 | 3 |
5 | 8 | 0.24 | 165 | 14.91 | 284 | 699 | 4.22 / 753.96 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 30 | 14.87 | 449 | 200 | 0.20 / 745.53 | 3 | 3 |
2 | 7 | 2011.36 | 53 | 14.78 | 3200 | 2507 | 2.71 / 748.04 | 2 | 2 |
3 | 13 | 1020.00 | 21 | 14.74 | 1829 | 566 | 3.27 / 748.60 | 2 | 3 |
4 | 13 | 415.04 | 21 | 14.85 | 957 | 298 | 3.57 / 748.90 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.91 | 289 | 711 | 4.28 / 749.61 | 2 | 3 |
6 | 14 | 0.12 | 30 | 14.88 | 288 | 129 | 4.41 / 749.74 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 30 | 14.86 | 467 | 208 | 0.21 / 741.35 | 3 | 3 |
2 | 7 | 2003.00 | 53 | 14.81 | 3184 | 2499 | 2.71 / 743.85 | 2 | 2 |
3 | 13 | 907.08 | 21 | 14.78 | 1669 | 518 | 3.23 / 744.37 | 2 | 3 |
4 | 13 | 329.48 | 21 | 14.90 | 825 | 258 | 3.48 / 744.63 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.92 | 286 | 704 | 4.19 / 745.33 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 30 | 14.86 | 460 | 205 | 0.21 / 737.09 | 3 | 3 |
2 | 7 | 2004.20 | 53 | 14.78 | 3190 | 2499 | 2.70 / 739.59 | 2 | 2 |
3 | 13 | 1016.32 | 21 | 14.75 | 1822 | 564 | 3.27 / 740.15 | 2 | 3 |
4 | 13 | 399.36 | 21 | 14.88 | 931 | 291 | 3.56 / 740.44 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.92 | 284 | 699 | 4.26 / 741.14 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 30 | 14.86 | 472 | 210 | 0.21 / 732.82 | 3 | 3 |
2 | 7 | 2013.04 | 53 | 14.79 | 3211 | 2517 | 2.73 / 735.33 | 2 | 2 |
3 | 13 | 1014.96 | 21 | 14.75 | 1821 | 564 | 3.29 / 735.90 | 2 | 3 |
4 | 13 | 398.36 | 21 | 14.87 | 929 | 290 | 3.58 / 736.19 | 2 | 3 |
5 | 8 | 0.00 | 165 | 14.91 | 283 | 696 | 4.28 / 736.89 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 30 | 14.87 | 474 | 211 | 0.21 / 728.50 | 3 | 3 |
2 | 7 | 2004.96 | 52 | 14.81 | 3192 | 2458 | 2.67 / 730.95 | 2 | 2 |
3 | 13 | 991.72 | 21 | 14.76 | 1786 | 554 | 3.22 / 731.51 | 2 | 3 |
4 | 13 | 396.84 | 21 | 14.87 | 926 | 289 | 3.51 / 731.80 | 2 | 3 |
5 | 13 | 19.68 | 21 | 14.95 | 321 | 101 | 3.61 / 731.90 | 2 | 2 |
6 | 8 | 0.08 | 165 | 14.90 | 289 | 711 | 4.32 / 732.61 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 30 | 14.85 | 457 | 204 | 0.20 / 724.27 | 3 | 3 |
2 | 7 | 2002.88 | 52 | 14.81 | 3194 | 2460 | 2.66 / 726.73 | 2 | 2 |
3 | 13 | 1017.16 | 21 | 14.77 | 1825 | 566 | 3.23 / 727.29 | 2 | 3 |
4 | 13 | 405.68 | 21 | 14.87 | 939 | 293 | 3.52 / 727.59 | 2 | 4 |
5 | 8 | 0.20 | 165 | 14.92 | 283 | 697 | 4.22 / 728.28 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.60 | 30 | 14.88 | 451 | 201 | 0.20 / 719.88 | 3 | 3 |
2 | 7 | 2004.36 | 53 | 14.81 | 3208 | 2518 | 2.72 / 722.39 | 2 | 2 |
3 | 13 | 1028.80 | 21 | 14.76 | 1841 | 571 | 3.29 / 722.96 | 2 | 3 |
4 | 13 | 412.64 | 21 | 14.86 | 951 | 297 | 3.59 / 723.26 | 2 | 3 |
5 | 13 | 21.64 | 21 | 14.94 | 325 | 102 | 3.69 / 723.36 | 2 | 3 |
6 | 8 | -0.04 | 165 | 14.90 | 285 | 701 | 4.39 / 724.06 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 30 | 14.87 | 456 | 203 | 0.20 / 715.57 | 3 | 3 |
2 | 7 | 2012.44 | 52 | 14.81 | 3217 | 2477 | 2.68 / 718.05 | 2 | 2 |
3 | 13 | 1169.20 | 21 | 14.73 | 2048 | 634 | 3.31 / 718.68 | 2 | 3 |
4 | 13 | 385.08 | 21 | 14.89 | 917 | 287 | 3.60 / 718.97 | 2 | 4 |
5 | 8 | 0.04 | 165 | 14.93 | 286 | 705 | 4.31 / 719.67 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 30 | 14.87 | 453 | 202 | 0.20 / 711.22 | 3 | 3 |
2 | 7 | 2008.52 | 52 | 14.82 | 3208 | 2472 | 2.67 / 713.69 | 2 | 2 |
3 | 13 | 1023.08 | 21 | 14.77 | 1842 | 571 | 3.25 / 714.26 | 2 | 3 |
4 | 13 | 406.96 | 21 | 14.88 | 946 | 296 | 3.54 / 714.56 | 2 | 3 |
5 | 13 | 21.92 | 21 | 14.96 | 328 | 103 | 3.64 / 714.66 | 2 | 2 |
6 | 8 | 0.08 | 165 | 14.92 | 288 | 709 | 4.35 / 715.37 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 30 | 14.87 | 460 | 205 | 0.21 / 706.93 | 3 | 3 |
2 | 7 | 2003.76 | 53 | 14.79 | 3199 | 2508 | 2.71 / 709.44 | 2 | 2 |
3 | 13 | 1023.16 | 21 | 14.76 | 1835 | 569 | 3.28 / 710.01 | 2 | 3 |
4 | 13 | 409.00 | 21 | 14.87 | 946 | 295 | 3.58 / 710.30 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.91 | 289 | 711 | 4.29 / 711.02 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 30 | 14.86 | 453 | 202 | 0.20 / 702.71 | 3 | 3 |
2 | 7 | 2008.52 | 53 | 14.80 | 3206 | 2515 | 2.72 / 705.22 | 2 | 2 |
3 | 13 | 1015.28 | 21 | 14.75 | 1830 | 567 | 3.28 / 705.79 | 2 | 3 |
4 | 13 | 306.28 | 21 | 14.89 | 782 | 245 | 3.53 / 706.03 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.92 | 283 | 697 | 4.22 / 706.73 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 30 | 14.86 | 459 | 205 | 0.20 / 698.50 | 3 | 3 |
2 | 7 | 2010.36 | 53 | 14.79 | 3199 | 2508 | 2.71 / 701.01 | 2 | 2 |
3 | 13 | 909.72 | 21 | 14.78 | 1673 | 519 | 3.23 / 701.53 | 2 | 3 |
4 | 13 | 341.92 | 21 | 14.88 | 845 | 264 | 3.50 / 701.79 | 2 | 3 |
5 | 8 | 0.24 | 165 | 14.91 | 290 | 713 | 4.21 / 702.50 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.08 | 30 | 14.87 | 465 | 207 | 0.21 / 694.27 | 3 | 3 |
2 | 7 | 2004.80 | 52 | 14.80 | 3191 | 2456 | 2.66 / 696.73 | 2 | 2 |
3 | 13 | 1024.08 | 21 | 14.75 | 1841 | 570 | 3.23 / 697.30 | 2 | 3 |
4 | 13 | 413.00 | 21 | 14.87 | 955 | 298 | 3.53 / 697.60 | 2 | 3 |
5 | 8 | 0.04 | 165 | 14.92 | 284 | 699 | 4.23 / 698.29 | 2 | 2 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 30 | 14.86 | 442 | 197 | 0.20 / 689.85 | 3 | 3 |
2 | 7 | 2008.76 | 53 | 14.80 | 3201 | 2511 | 2.71 / 692.36 | 2 | 2 |
3 | 13 | 1018.88 | 21 | 14.78 | 1835 | 570 | 3.28 / 692.93 | 2 | 3 |
4 | 13 | 410.68 | 21 | 14.89 | 958 | 300 | 3.58 / 693.23 | 2 | 3 |
5 | 13 | 46.56 | 21 | 14.95 | 368 | 116 | 3.69 / 693.34 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.92 | 293 | 721 | 4.41 / 694.06 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 30 | 14.87 | 445 | 199 | 0.20 / 685.52 | 3 | 3 |
2 | 7 | 2005.80 | 53 | 14.82 | 3195 | 2510 | 2.71 / 688.03 | 2 | 2 |
3 | 13 | 1025.96 | 21 | 14.77 | 1839 | 570 | 3.28 / 688.60 | 2 | 3 |
4 | 13 | 306.20 | 21 | 14.90 | 785 | 246 | 3.52 / 688.84 | 2 | 3 |
5 | 13 | 32.40 | 21 | 14.95 | 340 | 107 | 3.63 / 688.95 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.91 | 285 | 701 | 4.33 / 689.65 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 30 | 14.87 | 449 | 200 | 0.20 / 681.04 | 3 | 3 |
2 | 7 | 2012.96 | 53 | 14.82 | 3218 | 2528 | 2.73 / 683.57 | 2 | 2 |
3 | 13 | 1020.48 | 21 | 14.77 | 1831 | 568 | 3.30 / 684.14 | 2 | 3 |
4 | 13 | 315.40 | 21 | 14.90 | 800 | 250 | 3.55 / 684.39 | 2 | 3 |
5 | 13 | 34.96 | 21 | 14.95 | 346 | 109 | 3.65 / 684.50 | 2 | 2 |
6 | 8 | 0.00 | 165 | 14.92 | 282 | 694 | 4.35 / 685.19 | 2 | 3 |
7 | 14 | 0.00 | 30 | 14.90 | 283 | 127 | 4.48 / 685.32 | 3 | 6 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 30 | 14.88 | 443 | 198 | 0.20 / 676.67 | 3 | 3 |
2 | 7 | 2008.80 | 52 | 14.83 | 3210 | 2475 | 2.67 / 679.15 | 2 | 2 |
3 | 13 | 1026.12 | 21 | 14.77 | 1838 | 570 | 3.24 / 679.72 | 2 | 3 |
4 | 13 | 417.52 | 21 | 14.88 | 962 | 301 | 3.54 / 680.02 | 2 | 4 |
5 | 13 | 46.52 | 21 | 14.95 | 367 | 115 | 3.66 / 680.13 | 2 | 2 |
6 | 8 | 0.04 | 165 | 14.91 | 288 | 709 | 4.37 / 680.84 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 30 | 14.87 | 470 | 210 | 0.21 / 672.29 | 3 | 3 |
2 | 7 | 2003.56 | 53 | 14.82 | 3213 | 2524 | 2.73 / 674.82 | 2 | 2 |
3 | 13 | 1009.28 | 21 | 14.78 | 1817 | 564 | 3.30 / 675.38 | 2 | 3 |
4 | 13 | 393.84 | 21 | 14.91 | 924 | 289 | 3.59 / 675.67 | 2 | 3 |
5 | 13 | 24.04 | 21 | 14.96 | 329 | 103 | 3.69 / 675.77 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.93 | 285 | 702 | 4.39 / 676.47 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 30 | 14.87 | 450 | 201 | 0.20 / 667.90 | 3 | 3 |
2 | 7 | 2003.80 | 53 | 14.80 | 3195 | 2506 | 2.71 / 670.41 | 2 | 2 |
3 | 13 | 1007.48 | 21 | 14.77 | 1813 | 562 | 3.27 / 670.97 | 2 | 3 |
4 | 13 | 404.52 | 21 | 14.89 | 942 | 295 | 3.56 / 671.27 | 2 | 3 |
5 | 13 | 44.60 | 21 | 14.96 | 360 | 113 | 3.68 / 671.38 | 2 | 3 |
6 | 8 | 0.20 | 165 | 14.91 | 286 | 704 | 4.38 / 672.08 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 30 | 14.88 | 459 | 205 | 0.20 / 663.53 | 3 | 3 |
2 | 7 | 2010.68 | 53 | 14.82 | 3200 | 2513 | 2.72 / 666.04 | 2 | 2 |
3 | 13 | 1002.84 | 21 | 14.78 | 1802 | 559 | 3.28 / 666.60 | 2 | 3 |
4 | 13 | 390.08 | 21 | 14.90 | 918 | 287 | 3.56 / 666.89 | 2 | 3 |
5 | 13 | 45.72 | 21 | 14.96 | 360 | 113 | 3.68 / 667.00 | 2 | 2 |
6 | 8 | 0.04 | 165 | 14.92 | 285 | 702 | 4.38 / 667.70 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.80 | 30 | 14.88 | 478 | 213 | 0.21 / 659.10 | 3 | 3 |
2 | 7 | 2008.92 | 53 | 14.83 | 3213 | 2525 | 2.74 / 661.62 | 2 | 2 |
3 | 13 | 1022.20 | 21 | 14.78 | 1848 | 574 | 3.31 / 662.20 | 2 | 3 |
4 | 13 | 413.12 | 21 | 14.90 | 956 | 299 | 3.61 / 662.49 | 2 | 3 |
5 | 13 | 26.52 | 21 | 14.98 | 336 | 106 | 3.72 / 662.60 | 2 | 3 |
6 | 8 | 0.12 | 165 | 14.93 | 293 | 722 | 4.44 / 663.32 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 30 | 14.86 | 449 | 200 | 0.20 / 654.83 | 3 | 3 |
2 | 7 | 2004.12 | 52 | 14.83 | 3194 | 2463 | 2.66 / 657.29 | 2 | 2 |
3 | 13 | 903.72 | 21 | 14.80 | 1669 | 519 | 3.18 / 657.81 | 2 | 3 |
4 | 13 | 330.92 | 21 | 14.91 | 825 | 258 | 3.44 / 658.07 | 2 | 3 |
5 | 13 | 34.64 | 21 | 14.96 | 344 | 108 | 3.55 / 658.18 | 2 | 3 |
6 | 8 | -0.04 | 165 | 14.93 | 286 | 705 | 4.25 / 658.88 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 30 | 14.87 | 448 | 200 | 0.20 / 650.45 | 3 | 3 |
2 | 7 | 2002.76 | 53 | 14.81 | 3195 | 2508 | 2.71 / 652.95 | 2 | 2 |
3 | 13 | 1018.72 | 21 | 14.78 | 1828 | 567 | 3.28 / 653.52 | 2 | 3 |
4 | 13 | 411.56 | 21 | 14.89 | 953 | 298 | 3.57 / 653.82 | 2 | 3 |
5 | 13 | 21.24 | 21 | 14.97 | 325 | 102 | 3.68 / 653.92 | 2 | 3 |
6 | 8 | -0.04 | 165 | 14.92 | 288 | 709 | 4.38 / 654.63 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 30 | 14.88 | 453 | 202 | 0.20 / 646.09 | 3 | 3 |
2 | 7 | 2003.28 | 53 | 14.81 | 3198 | 2510 | 2.71 / 648.60 | 2 | 2 |
3 | 13 | 1000.20 | 21 | 14.77 | 1803 | 559 | 3.27 / 649.16 | 2 | 3 |
4 | 13 | 385.36 | 21 | 14.89 | 913 | 285 | 3.56 / 649.44 | 2 | 3 |
5 | 13 | 20.52 | 21 | 14.94 | 323 | 101 | 3.66 / 649.54 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.91 | 286 | 704 | 4.36 / 650.25 | 2 | 4 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 30 | 14.89 | 472 | 211 | 0.21 / 641.68 | 3 | 3 |
2 | 7 | 2004.16 | 53 | 14.82 | 3207 | 2519 | 2.73 / 644.19 | 2 | 2 |
3 | 13 | 1014.60 | 21 | 14.77 | 1826 | 566 | 3.30 / 644.76 | 2 | 3 |
4 | 13 | 417.52 | 21 | 14.89 | 972 | 304 | 3.60 / 645.07 | 2 | 3 |
5 | 13 | 21.68 | 21 | 14.96 | 332 | 104 | 3.70 / 645.17 | 2 | 2 |
6 | 8 | 0.12 | 165 | 14.93 | 290 | 714 | 4.42 / 645.88 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 30 | 14.89 | 458 | 205 | 0.20 / 637.34 | 3 | 3 |
2 | 7 | 2002.96 | 52 | 14.83 | 3202 | 2469 | 2.67 / 639.81 | 2 | 2 |
3 | 13 | 1034.28 | 21 | 14.78 | 1860 | 577 | 3.25 / 640.39 | 2 | 3 |
4 | 13 | 314.92 | 21 | 14.92 | 810 | 254 | 3.50 / 640.64 | 2 | 3 |
5 | 13 | 16.88 | 21 | 14.97 | 325 | 102 | 3.61 / 640.75 | 2 | 2 |
6 | 8 | 0.00 | 165 | 14.94 | 292 | 720 | 4.33 / 641.47 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 30 | 14.89 | 477 | 213 | 0.21 / 632.94 | 3 | 3 |
2 | 7 | 2005.80 | 53 | 14.84 | 3199 | 2516 | 2.73 / 635.45 | 2 | 2 |
3 | 13 | 1018.80 | 21 | 14.79 | 1838 | 571 | 3.30 / 636.02 | 2 | 3 |
4 | 13 | 403.12 | 21 | 14.92 | 947 | 297 | 3.60 / 636.32 | 2 | 4 |
5 | 13 | 19.40 | 21 | 14.98 | 327 | 103 | 3.70 / 636.42 | 2 | 2 |
6 | 8 | 0.20 | 165 | 14.95 | 290 | 715 | 4.41 / 637.14 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 30 | 14.88 | 454 | 203 | 0.20 / 628.55 | 3 | 3 |
2 | 7 | 2007.64 | 53 | 14.82 | 3189 | 2505 | 2.71 / 631.06 | 2 | 2 |
3 | 13 | 1007.48 | 21 | 14.78 | 1818 | 564 | 3.27 / 631.62 | 2 | 3 |
4 | 13 | 383.40 | 21 | 14.91 | 909 | 285 | 3.56 / 631.90 | 2 | 3 |
5 | 13 | 19.72 | 21 | 14.98 | 322 | 101 | 3.66 / 632.01 | 2 | 2 |
6 | 8 | 0.00 | 165 | 14.94 | 291 | 717 | 4.38 / 632.72 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 30 | 14.90 | 456 | 204 | 0.20 / 624.35 | 3 | 3 |
2 | 7 | 2004.04 | 53 | 14.82 | 3186 | 2502 | 2.71 / 626.86 | 2 | 2 |
3 | 13 | 894.32 | 21 | 14.82 | 1656 | 515 | 3.22 / 627.37 | 2 | 3 |
4 | 13 | 326.04 | 21 | 14.92 | 826 | 259 | 3.48 / 627.63 | 2 | 3 |
5 | 8 | 0.04 | 165 | 14.94 | 291 | 717 | 4.20 / 628.35 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 30 | 14.88 | 482 | 215 | 0.22 / 620.04 | 3 | 3 |
2 | 7 | 2009.36 | 53 | 14.82 | 3204 | 2517 | 2.73 / 622.55 | 2 | 2 |
3 | 13 | 1032.76 | 21 | 14.77 | 1861 | 577 | 3.31 / 623.13 | 2 | 3 |
4 | 13 | 424.20 | 21 | 14.90 | 977 | 306 | 3.61 / 623.44 | 2 | 3 |
5 | 8 | 0.04 | 165 | 14.95 | 290 | 715 | 4.33 / 624.15 | 2 | 3 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 30 | 14.90 | 475 | 212 | 0.21 / 615.73 | 3 | 3 |
2 | 7 | 2008.08 | 53 | 14.82 | 3194 | 2509 | 2.72 / 618.24 | 2 | 2 |
3 | 13 | 1015.24 | 21 | 14.78 | 1823 | 566 | 3.29 / 618.81 | 2 | 3 |
4 | 13 | 406.00 | 21 | 14.91 | 946 | 296 | 3.58 / 619.10 | 2 | 3 |
5 | 8 | 0.08 | 165 | 14.94 | 291 | 717 | 4.30 / 619.82 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.72 | 30 | 14.89 | 478 | 214 | 0.21 / 611.48 | 3 | 3 |
2 | 7 | 2004.28 | 52 | 14.83 | 3200 | 2468 | 2.68 / 613.95 | 2 | 2 |
3 | 13 | 1006.52 | 21 | 14.78 | 1812 | 562 | 3.24 / 614.51 | 2 | 2 |
4 | 13 | 400.92 | 21 | 14.90 | 936 | 293 | 3.54 / 614.80 | 2 | 3 |
5 | 8 | 0.08 | 165 | 14.95 | 290 | 715 | 4.25 / 615.52 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 30 | 14.90 | 487 | 218 | 0.22 / 607.17 | 3 | 3 |
2 | 7 | 2006.92 | 53 | 14.81 | 3199 | 2511 | 2.73 / 609.68 | 2 | 2 |
3 | 13 | 1028.96 | 21 | 14.79 | 1847 | 574 | 3.30 / 610.25 | 2 | 3 |
4 | 13 | 410.16 | 21 | 14.92 | 952 | 298 | 3.60 / 610.55 | 2 | 3 |
5 | 8 | 0.00 | 165 | 14.95 | 291 | 718 | 4.32 / 611.27 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 30 | 14.89 | 483 | 216 | 0.22 / 602.85 | 3 | 3 |
2 | 7 | 2007.36 | 53 | 14.82 | 3198 | 2512 | 2.73 / 605.36 | 2 | 2 |
3 | 13 | 1009.72 | 21 | 14.79 | 1822 | 566 | 3.29 / 605.93 | 2 | 3 |
4 | 13 | 410.24 | 21 | 14.91 | 961 | 301 | 3.59 / 606.23 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.96 | 293 | 723 | 4.32 / 606.95 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 30 | 14.89 | 483 | 216 | 0.22 / 598.44 | 3 | 3 |
2 | 7 | 2007.00 | 53 | 14.83 | 3186 | 2504 | 2.72 / 600.95 | 2 | 2 |
3 | 13 | 1007.96 | 21 | 14.79 | 1817 | 564 | 3.28 / 601.51 | 2 | 3 |
4 | 13 | 402.44 | 21 | 14.92 | 937 | 294 | 3.58 / 601.81 | 2 | 3 |
5 | 13 | 20.88 | 21 | 14.98 | 327 | 103 | 3.68 / 601.91 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.94 | 293 | 722 | 4.40 / 602.63 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 30 | 14.89 | 478 | 214 | 0.21 / 594.14 | 3 | 3 |
2 | 7 | 2003.20 | 53 | 14.83 | 3192 | 2509 | 2.72 / 596.65 | 2 | 2 |
3 | 13 | 1027.40 | 21 | 14.78 | 1842 | 572 | 3.29 / 597.22 | 2 | 3 |
4 | 13 | 408.76 | 21 | 14.90 | 952 | 298 | 3.59 / 597.52 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.95 | 289 | 713 | 4.30 / 598.23 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 30 | 14.89 | 476 | 213 | 0.21 / 589.84 | 3 | 3 |
2 | 7 | 2010.68 | 53 | 14.83 | 3215 | 2527 | 2.74 / 592.37 | 2 | 2 |
3 | 13 | 904.80 | 21 | 14.82 | 1668 | 519 | 3.26 / 592.89 | 2 | 3 |
4 | 13 | 464.16 | 21 | 14.89 | 1033 | 323 | 3.58 / 593.21 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.95 | 289 | 713 | 4.29 / 593.92 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 29 | 14.90 | 474 | 205 | 0.20 / 585.55 | 3 | 3 |
2 | 7 | 2004.52 | 53 | 14.83 | 3193 | 2510 | 2.71 / 588.06 | 2 | 2 |
3 | 13 | 1010.88 | 21 | 14.80 | 1812 | 563 | 3.28 / 588.62 | 2 | 3 |
4 | 13 | 403.08 | 21 | 14.92 | 938 | 294 | 3.57 / 588.91 | 2 | 3 |
5 | 8 | 0.08 | 165 | 14.95 | 290 | 715 | 4.29 / 589.63 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 29 | 14.89 | 478 | 206 | 0.21 / 581.12 | 3 | 3 |
2 | 7 | 2011.08 | 53 | 14.83 | 3206 | 2520 | 2.73 / 583.64 | 2 | 2 |
3 | 13 | 1020.60 | 21 | 14.80 | 1832 | 569 | 3.30 / 584.21 | 2 | 3 |
4 | 13 | 406.16 | 21 | 14.90 | 945 | 296 | 3.59 / 584.51 | 2 | 3 |
5 | 8 | 0.08 | 165 | 14.95 | 287 | 708 | 4.30 / 585.22 | 2 | 3 |
6 | 14 | 0.08 | 30 | 14.93 | 283 | 127 | 4.43 / 585.34 | 3 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 29 | 14.89 | 456 | 197 | 0.20 / 576.81 | 3 | 3 |
2 | 7 | 2009.52 | 53 | 14.82 | 3193 | 2508 | 2.70 / 579.32 | 2 | 2 |
3 | 13 | 1017.72 | 21 | 14.78 | 1838 | 570 | 3.28 / 579.89 | 2 | 3 |
4 | 13 | 402.84 | 21 | 14.90 | 941 | 294 | 3.57 / 580.18 | 2 | 4 |
5 | 8 | 0.12 | 165 | 14.94 | 297 | 732 | 4.30 / 580.92 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 29 | 14.91 | 478 | 207 | 0.21 / 572.29 | 3 | 3 |
2 | 7 | 2003.44 | 53 | 14.83 | 3188 | 2506 | 2.71 / 574.80 | 2 | 2 |
3 | 13 | 996.16 | 21 | 14.80 | 1800 | 559 | 3.27 / 575.36 | 2 | 3 |
4 | 13 | 390.84 | 21 | 14.90 | 924 | 289 | 3.56 / 575.64 | 2 | 3 |
5 | 13 | 23.88 | 21 | 14.97 | 339 | 107 | 3.67 / 575.75 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.93 | 297 | 732 | 4.40 / 576.48 | 2 | 3 |
7 | 14 | 0.00 | 30 | 14.92 | 295 | 132 | 4.53 / 576.61 | 3 | 5 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 29 | 14.90 | 452 | 195 | 0.20 / 567.98 | 3 | 3 |
2 | 7 | 2011.68 | 53 | 14.84 | 3211 | 2526 | 2.72 / 570.50 | 2 | 2 |
3 | 13 | 1015.04 | 21 | 14.80 | 1834 | 570 | 3.29 / 571.07 | 2 | 3 |
4 | 13 | 400.36 | 21 | 14.91 | 941 | 295 | 3.59 / 571.37 | 2 | 3 |
5 | 8 | -0.08 | 165 | 14.95 | 290 | 715 | 4.30 / 572.08 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 29 | 14.91 | 470 | 203 | 0.20 / 563.69 | 3 | 3 |
2 | 7 | 2003.04 | 53 | 14.84 | 3194 | 2512 | 2.72 / 566.20 | 2 | 2 |
3 | 13 | 1034.12 | 21 | 14.79 | 1862 | 578 | 3.29 / 566.78 | 2 | 3 |
4 | 13 | 414.40 | 21 | 14.91 | 960 | 301 | 3.59 / 567.08 | 2 | 4 |
5 | 8 | 0.08 | 165 | 14.96 | 286 | 706 | 4.30 / 567.78 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.44 | 29 | 14.90 | 456 | 197 | 0.20 / 559.28 | 3 | 3 |
2 | 7 | 2011.28 | 53 | 14.84 | 3197 | 2515 | 2.71 / 561.80 | 2 | 2 |
3 | 13 | 1004.92 | 21 | 14.81 | 1798 | 559 | 3.27 / 562.35 | 2 | 3 |
4 | 13 | 398.24 | 21 | 14.92 | 930 | 291 | 3.56 / 562.65 | 2 | 3 |
5 | 8 | 0.16 | 165 | 14.95 | 287 | 708 | 4.27 / 563.35 | 2 | 3 |
6 | 14 | 0.16 | 30 | 14.94 | 286 | 128 | 4.40 / 563.48 | 3 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 29 | 14.89 | 481 | 208 | 0.21 / 555.08 | 3 | 3 |
2 | 7 | 2002.76 | 53 | 14.81 | 3187 | 2502 | 2.71 / 557.58 | 2 | 2 |
3 | 13 | 1003.32 | 21 | 14.79 | 1819 | 565 | 3.27 / 558.15 | 2 | 3 |
4 | 13 | 289.08 | 21 | 14.92 | 757 | 237 | 3.51 / 558.38 | 2 | 3 |
5 | 8 | 0.04 | 165 | 14.95 | 284 | 701 | 4.21 / 559.08 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 29 | 14.89 | 452 | 195 | 0.20 / 550.79 | 3 | 3 |
2 | 7 | 2010.00 | 53 | 14.82 | 3208 | 2520 | 2.71 / 553.30 | 2 | 2 |
3 | 13 | 1008.12 | 21 | 14.78 | 1811 | 562 | 3.28 / 553.87 | 2 | 3 |
4 | 13 | 398.28 | 21 | 14.91 | 933 | 292 | 3.57 / 554.16 | 2 | 3 |
5 | 8 | 0.16 | 165 | 14.95 | 289 | 713 | 4.28 / 554.87 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 29 | 14.89 | 458 | 198 | 0.20 / 546.38 | 3 | 3 |
2 | 7 | 2009.76 | 53 | 14.83 | 3204 | 2518 | 2.72 / 548.90 | 2 | 2 |
3 | 13 | 1014.16 | 21 | 14.80 | 1834 | 570 | 3.29 / 549.47 | 2 | 3 |
4 | 13 | 410.20 | 21 | 14.92 | 956 | 300 | 3.59 / 549.77 | 2 | 3 |
5 | 13 | 44.96 | 21 | 14.97 | 365 | 115 | 3.70 / 549.88 | 2 | 2 |
6 | 8 | -0.04 | 165 | 14.94 | 288 | 710 | 4.41 / 550.59 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 29 | 14.88 | 471 | 203 | 0.20 / 541.98 | 3 | 3 |
2 | 7 | 2005.36 | 53 | 14.82 | 3192 | 2507 | 2.71 / 544.49 | 2 | 2 |
3 | 13 | 1020.72 | 21 | 14.78 | 1828 | 567 | 3.28 / 545.05 | 2 | 3 |
4 | 13 | 406.04 | 21 | 14.89 | 948 | 296 | 3.57 / 545.35 | 2 | 3 |
5 | 13 | 23.16 | 21 | 14.97 | 331 | 104 | 3.68 / 545.45 | 2 | 2 |
6 | 8 | 0.12 | 165 | 14.93 | 295 | 727 | 4.41 / 546.18 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 30 | 14.90 | 446 | 199 | 0.20 / 537.52 | 3 | 3 |
2 | 7 | 2004.48 | 53 | 14.84 | 3199 | 2516 | 2.72 / 540.03 | 2 | 2 |
3 | 13 | 1033.64 | 21 | 14.80 | 1853 | 576 | 3.29 / 540.61 | 2 | 3 |
4 | 13 | 418.16 | 21 | 14.91 | 970 | 304 | 3.60 / 540.91 | 2 | 3 |
5 | 13 | 47.40 | 21 | 14.97 | 378 | 119 | 3.71 / 541.03 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.94 | 301 | 742 | 4.46 / 541.77 | 2 | 3 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 30 | 14.90 | 466 | 208 | 0.21 / 533.20 | 3 | 3 |
2 | 7 | 2005.96 | 53 | 14.83 | 3206 | 2520 | 2.73 / 535.72 | 2 | 2 |
3 | 13 | 908.20 | 21 | 14.82 | 1676 | 522 | 3.25 / 536.24 | 2 | 3 |
4 | 13 | 335.56 | 21 | 14.93 | 838 | 263 | 3.51 / 536.50 | 2 | 3 |
5 | 13 | 33.88 | 21 | 14.99 | 344 | 108 | 3.62 / 536.61 | 2 | 2 |
6 | 8 | 0.12 | 165 | 14.95 | 286 | 705 | 4.33 / 537.32 | 2 | 5 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.72 | 30 | 14.89 | 448 | 200 | 0.20 / 528.80 | 3 | 3 |
2 | 7 | 2008.84 | 53 | 14.82 | 3207 | 2519 | 2.72 / 531.32 | 2 | 2 |
3 | 13 | 1015.56 | 21 | 14.80 | 1827 | 568 | 3.29 / 531.89 | 2 | 3 |
4 | 13 | 393.92 | 21 | 14.92 | 930 | 291 | 3.58 / 532.18 | 2 | 3 |
5 | 13 | 45.32 | 21 | 14.98 | 361 | 114 | 3.69 / 532.29 | 2 | 2 |
6 | 8 | 0.04 | 165 | 14.94 | 284 | 700 | 4.39 / 532.99 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 30 | 14.89 | 445 | 199 | 0.20 / 524.43 | 3 | 3 |
2 | 7 | 2009.32 | 53 | 14.82 | 3193 | 2508 | 2.71 / 526.94 | 2 | 2 |
3 | 13 | 1014.56 | 21 | 14.79 | 1820 | 565 | 3.27 / 527.50 | 2 | 3 |
4 | 13 | 397.16 | 21 | 14.90 | 928 | 290 | 3.56 / 527.79 | 2 | 3 |
5 | 13 | 22.40 | 21 | 14.97 | 328 | 103 | 3.67 / 527.90 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.95 | 285 | 703 | 4.37 / 528.60 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 30 | 14.91 | 475 | 212 | 0.21 / 520.13 | 3 | 3 |
2 | 7 | 2005.92 | 53 | 14.83 | 3186 | 2504 | 2.72 / 522.63 | 2 | 2 |
3 | 13 | 902.04 | 21 | 14.83 | 1669 | 520 | 3.24 / 523.15 | 2 | 3 |
4 | 13 | 328.72 | 21 | 14.93 | 827 | 259 | 3.50 / 523.41 | 2 | 3 |
5 | 13 | 34.40 | 21 | 14.98 | 345 | 109 | 3.60 / 523.52 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.94 | 289 | 712 | 4.32 / 524.23 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 30 | 14.90 | 479 | 214 | 0.21 / 515.81 | 3 | 3 |
2 | 7 | 2010.44 | 53 | 14.85 | 3204 | 2522 | 2.74 / 518.33 | 2 | 2 |
3 | 13 | 900.16 | 21 | 14.83 | 1663 | 518 | 3.25 / 518.85 | 2 | 3 |
4 | 13 | 324.56 | 21 | 14.94 | 818 | 257 | 3.51 / 519.10 | 2 | 3 |
5 | 13 | 35.12 | 21 | 15.00 | 344 | 108 | 3.62 / 519.21 | 2 | 3 |
6 | 8 | -0.04 | 165 | 14.96 | 285 | 703 | 4.32 / 519.92 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 29 | 14.91 | 457 | 198 | 0.20 / 511.41 | 3 | 3 |
2 | 7 | 2004.20 | 53 | 14.84 | 3191 | 2510 | 2.71 / 513.92 | 2 | 2 |
3 | 13 | 1010.12 | 21 | 14.81 | 1828 | 569 | 3.28 / 514.49 | 2 | 3 |
4 | 13 | 383.04 | 21 | 14.93 | 917 | 288 | 3.56 / 514.77 | 2 | 3 |
5 | 13 | 22.64 | 21 | 14.99 | 330 | 104 | 3.67 / 514.88 | 2 | 2 |
6 | 8 | 0.08 | 165 | 14.95 | 290 | 715 | 4.38 / 515.59 | 2 | 4 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 29 | 14.92 | 443 | 192 | 0.19 / 507.07 | 3 | 3 |
2 | 7 | 2005.80 | 53 | 14.85 | 3201 | 2519 | 2.71 / 509.59 | 2 | 2 |
3 | 13 | 1017.20 | 21 | 14.81 | 1835 | 571 | 3.28 / 510.16 | 2 | 3 |
4 | 13 | 290.84 | 21 | 14.96 | 765 | 240 | 3.52 / 510.41 | 2 | 3 |
5 | 13 | 27.16 | 21 | 14.99 | 331 | 104 | 3.63 / 510.51 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.96 | 284 | 701 | 4.33 / 511.21 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 29 | 14.91 | 473 | 205 | 0.20 / 502.89 | 3 | 3 |
2 | 7 | 2003.16 | 53 | 14.86 | 3191 | 2513 | 2.72 / 505.40 | 2 | 2 |
3 | 13 | 919.28 | 21 | 14.83 | 1687 | 525 | 3.24 / 505.92 | 2 | 3 |
4 | 13 | 332.60 | 21 | 14.94 | 828 | 260 | 3.50 / 506.18 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.96 | 283 | 699 | 4.20 / 506.88 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 29 | 14.91 | 447 | 193 | 0.19 / 498.52 | 3 | 3 |
2 | 7 | 2009.36 | 52 | 14.85 | 3210 | 2479 | 2.67 / 501.00 | 2 | 2 |
3 | 13 | 1009.52 | 21 | 14.82 | 1816 | 565 | 3.24 / 501.57 | 2 | 3 |
4 | 13 | 393.76 | 21 | 14.94 | 928 | 291 | 3.53 / 501.86 | 2 | 3 |
5 | 13 | 41.68 | 21 | 15.00 | 353 | 111 | 3.64 / 501.97 | 2 | 2 |
6 | 8 | 0.00 | 165 | 14.97 | 288 | 711 | 4.35 / 502.68 | 2 | 4 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 29 | 14.90 | 454 | 196 | 0.20 / 494.12 | 3 | 3 |
2 | 7 | 2003.04 | 53 | 14.86 | 3204 | 2523 | 2.72 / 496.65 | 2 | 2 |
3 | 13 | 1018.80 | 21 | 14.81 | 1847 | 574 | 3.29 / 497.22 | 2 | 3 |
4 | 13 | 408.48 | 21 | 14.92 | 958 | 300 | 3.59 / 497.52 | 2 | 3 |
5 | 13 | 24.48 | 21 | 14.99 | 332 | 105 | 3.70 / 497.63 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.96 | 285 | 703 | 4.40 / 498.33 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 29 | 14.93 | 454 | 197 | 0.20 / 489.71 | 3 | 3 |
2 | 7 | 2010.96 | 53 | 14.83 | 3194 | 2510 | 2.71 / 492.22 | 2 | 2 |
3 | 13 | 1024.88 | 21 | 14.80 | 1841 | 572 | 3.28 / 492.80 | 2 | 3 |
4 | 13 | 411.88 | 21 | 14.92 | 957 | 300 | 3.58 / 493.10 | 2 | 3 |
5 | 13 | 20.84 | 21 | 14.99 | 334 | 105 | 3.68 / 493.20 | 2 | 2 |
6 | 8 | 0.04 | 165 | 14.95 | 295 | 728 | 4.41 / 493.93 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.32 | 29 | 14.91 | 484 | 209 | 0.21 / 485.48 | 3 | 3 |
2 | 7 | 2007.88 | 53 | 14.86 | 3199 | 2519 | 2.73 / 488.00 | 2 | 2 |
3 | 13 | 1016.84 | 21 | 14.82 | 1826 | 568 | 3.30 / 488.56 | 2 | 2 |
4 | 13 | 291.16 | 21 | 14.97 | 766 | 241 | 3.54 / 488.81 | 2 | 3 |
5 | 8 | 0.00 | 165 | 14.97 | 288 | 711 | 4.25 / 489.52 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 29 | 14.91 | 475 | 205 | 0.21 / 481.07 | 3 | 3 |
2 | 7 | 2003.64 | 53 | 14.86 | 3197 | 2518 | 2.72 / 483.59 | 2 | 2 |
3 | 13 | 1006.12 | 21 | 14.83 | 1817 | 566 | 3.29 / 484.16 | 2 | 3 |
4 | 13 | 377.20 | 21 | 14.95 | 900 | 283 | 3.57 / 484.44 | 2 | 3 |
5 | 13 | 19.28 | 21 | 15.01 | 324 | 102 | 3.67 / 484.54 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.98 | 293 | 724 | 4.40 / 485.27 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.56 | 29 | 14.95 | 475 | 206 | 0.21 / 476.73 | 3 | 3 |
2 | 7 | 2003.96 | 52 | 14.85 | 3191 | 2464 | 2.67 / 479.20 | 2 | 2 |
3 | 13 | 1010.44 | 21 | 14.82 | 1826 | 568 | 3.24 / 479.77 | 2 | 3 |
4 | 13 | 392.84 | 21 | 14.94 | 930 | 292 | 3.53 / 480.06 | 2 | 3 |
5 | 13 | 20.44 | 21 | 15.00 | 325 | 102 | 3.63 / 480.16 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.98 | 287 | 709 | 4.34 / 480.87 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 29 | 14.92 | 455 | 197 | 0.20 / 472.50 | 3 | 3 |
2 | 7 | 2002.84 | 53 | 14.86 | 3194 | 2516 | 2.71 / 475.01 | 2 | 2 |
3 | 13 | 1003.92 | 21 | 14.82 | 1814 | 565 | 3.28 / 475.58 | 2 | 3 |
4 | 13 | 280.20 | 21 | 14.98 | 749 | 236 | 3.51 / 475.81 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.98 | 289 | 714 | 4.23 / 476.53 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.72 | 29 | 14.94 | 476 | 206 | 0.21 / 468.22 | 3 | 3 |
2 | 7 | 2003.32 | 53 | 14.86 | 3188 | 2511 | 2.72 / 470.73 | 2 | 2 |
3 | 13 | 993.44 | 21 | 14.83 | 1794 | 559 | 3.28 / 471.29 | 2 | 3 |
4 | 13 | 378.52 | 21 | 14.95 | 906 | 284 | 3.56 / 471.57 | 2 | 3 |
5 | 8 | 0.16 | 165 | 14.98 | 294 | 727 | 4.29 / 472.30 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 29 | 14.94 | 476 | 206 | 0.21 / 464.01 | 3 | 3 |
2 | 7 | 2010.48 | 53 | 14.85 | 3205 | 2522 | 2.73 / 466.53 | 2 | 2 |
3 | 13 | 894.76 | 21 | 14.85 | 1646 | 513 | 3.24 / 467.04 | 2 | 3 |
4 | 13 | 321.44 | 21 | 14.96 | 810 | 254 | 3.50 / 467.30 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.00 | 290 | 718 | 4.21 / 468.01 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 29 | 14.93 | 466 | 202 | 0.20 / 459.73 | 3 | 3 |
2 | 7 | 2003.96 | 53 | 14.87 | 3183 | 2509 | 2.71 / 462.23 | 2 | 2 |
3 | 13 | 1003.88 | 21 | 14.84 | 1817 | 566 | 3.28 / 462.80 | 2 | 3 |
4 | 13 | 385.36 | 21 | 14.96 | 919 | 289 | 3.57 / 463.09 | 2 | 4 |
5 | 8 | 0.12 | 165 | 14.99 | 287 | 710 | 4.28 / 463.80 | 2 | 3 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.04 | 29 | 14.94 | 485 | 210 | 0.21 / 455.44 | 3 | 3 |
2 | 7 | 2005.96 | 52 | 14.88 | 3203 | 2478 | 2.69 / 457.92 | 2 | 2 |
3 | 13 | 1003.56 | 21 | 14.84 | 1817 | 566 | 3.25 / 458.49 | 2 | 3 |
4 | 13 | 390.60 | 21 | 14.95 | 939 | 295 | 3.55 / 458.78 | 2 | 3 |
5 | 8 | 0.04 | 165 | 14.99 | 301 | 744 | 4.29 / 459.52 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 29 | 14.95 | 479 | 208 | 0.21 / 451.13 | 3 | 3 |
2 | 7 | 2008.60 | 53 | 14.86 | 3196 | 2517 | 2.72 / 453.65 | 2 | 2 |
3 | 13 | 1006.04 | 21 | 14.84 | 1818 | 567 | 3.29 / 454.22 | 2 | 3 |
4 | 13 | 387.24 | 21 | 14.96 | 921 | 289 | 3.58 / 454.51 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.01 | 292 | 723 | 4.30 / 455.23 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 29 | 14.93 | 458 | 198 | 0.20 / 446.87 | 3 | 3 |
2 | 7 | 2005.00 | 53 | 14.88 | 3202 | 2525 | 2.72 / 449.40 | 2 | 2 |
3 | 13 | 1023.60 | 21 | 14.83 | 1842 | 574 | 3.30 / 449.97 | 2 | 3 |
4 | 13 | 291.84 | 21 | 14.99 | 769 | 242 | 3.54 / 450.21 | 2 | 3 |
5 | 8 | 0.00 | 165 | 14.99 | 289 | 715 | 4.25 / 450.93 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 29 | 14.94 | 477 | 207 | 0.21 / 442.58 | 2 | 3 |
2 | 7 | 2010.24 | 53 | 14.87 | 3205 | 2526 | 2.73 / 445.10 | 2 | 2 |
3 | 13 | 1000.68 | 21 | 14.83 | 1804 | 562 | 3.29 / 445.66 | 2 | 3 |
4 | 13 | 389.40 | 21 | 14.95 | 927 | 291 | 3.59 / 445.95 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.00 | 290 | 718 | 4.30 / 446.67 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 29 | 14.94 | 447 | 194 | 0.19 / 438.34 | 2 | 3 |
2 | 7 | 2003.88 | 53 | 14.87 | 3180 | 2506 | 2.70 / 440.84 | 2 | 2 |
3 | 13 | 876.00 | 21 | 14.86 | 1626 | 507 | 3.21 / 441.35 | 2 | 3 |
4 | 13 | 429.16 | 21 | 14.95 | 981 | 308 | 3.52 / 441.66 | 2 | 3 |
5 | 8 | 0.04 | 165 | 14.99 | 287 | 710 | 4.23 / 442.37 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 29 | 14.93 | 446 | 193 | 0.19 / 434.08 | 3 | 3 |
2 | 7 | 2009.40 | 53 | 14.85 | 3193 | 2513 | 2.71 / 436.59 | 2 | 2 |
3 | 13 | 998.32 | 21 | 14.82 | 1794 | 558 | 3.26 / 437.15 | 2 | 3 |
4 | 13 | 389.88 | 21 | 14.95 | 919 | 289 | 3.55 / 437.44 | 2 | 3 |
5 | 8 | 0.00 | 165 | 14.99 | 285 | 705 | 4.26 / 438.14 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 29 | 14.92 | 457 | 198 | 0.20 / 429.80 | 2 | 3 |
2 | 7 | 2010.12 | 53 | 14.85 | 3206 | 2523 | 2.72 / 432.32 | 2 | 2 |
3 | 13 | 1017.40 | 21 | 14.83 | 1830 | 570 | 3.29 / 432.89 | 2 | 3 |
4 | 13 | 402.40 | 21 | 14.95 | 941 | 295 | 3.59 / 433.19 | 2 | 3 |
5 | 8 | 0.16 | 165 | 14.97 | 282 | 697 | 4.28 / 433.89 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 29 | 14.95 | 483 | 209 | 0.21 / 425.51 | 3 | 3 |
2 | 7 | 2009.60 | 53 | 14.85 | 3189 | 2510 | 2.72 / 428.02 | 2 | 2 |
3 | 13 | 1017.56 | 21 | 14.82 | 1817 | 565 | 3.28 / 428.59 | 2 | 3 |
4 | 13 | 412.00 | 21 | 14.94 | 953 | 299 | 3.58 / 428.89 | 2 | 3 |
5 | 8 | 0.04 | 165 | 14.98 | 290 | 717 | 4.30 / 429.60 | 2 | 2 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 29 | 14.94 | 490 | 212 | 0.21 / 421.24 | 3 | 3 |
2 | 7 | 2008.08 | 53 | 14.88 | 3205 | 2528 | 2.74 / 423.76 | 2 | 2 |
3 | 13 | 1029.64 | 21 | 14.83 | 1843 | 574 | 3.31 / 424.34 | 2 | 3 |
4 | 13 | 297.44 | 21 | 14.99 | 769 | 242 | 3.56 / 424.58 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.00 | 292 | 723 | 4.28 / 425.30 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 29 | 14.94 | 453 | 196 | 0.20 / 416.95 | 3 | 3 |
2 | 7 | 2010.04 | 52 | 14.86 | 3210 | 2480 | 2.68 / 419.43 | 2 | 2 |
3 | 13 | 1011.52 | 21 | 14.84 | 1818 | 567 | 3.24 / 420.00 | 2 | 3 |
4 | 13 | 402.76 | 21 | 14.96 | 945 | 297 | 3.54 / 420.29 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.00 | 295 | 730 | 4.27 / 421.02 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.96 | 29 | 14.94 | 466 | 202 | 0.20 / 412.76 | 3 | 3 |
2 | 7 | 2003.44 | 53 | 14.87 | 3184 | 2509 | 2.71 / 415.27 | 2 | 2 |
3 | 13 | 901.64 | 21 | 14.86 | 1663 | 519 | 3.23 / 415.78 | 2 | 3 |
4 | 13 | 328.88 | 21 | 14.98 | 824 | 259 | 3.49 / 416.04 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.00 | 287 | 710 | 4.20 / 416.75 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 29 | 14.96 | 448 | 194 | 0.19 / 408.36 | 3 | 3 |
2 | 7 | 2004.04 | 53 | 14.87 | 3191 | 2515 | 2.71 / 410.88 | 2 | 2 |
3 | 13 | 1007.24 | 21 | 14.84 | 1813 | 565 | 3.27 / 411.44 | 2 | 3 |
4 | 13 | 398.08 | 21 | 14.97 | 927 | 291 | 3.57 / 411.73 | 2 | 3 |
5 | 13 | 44.80 | 21 | 15.03 | 360 | 114 | 3.68 / 411.85 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.01 | 285 | 706 | 4.39 / 412.55 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 29 | 14.95 | 442 | 192 | 0.19 / 404.14 | 3 | 3 |
2 | 7 | 2004.32 | 52 | 14.89 | 3189 | 2469 | 2.66 / 406.61 | 2 | 2 |
3 | 13 | 999.08 | 21 | 14.85 | 1797 | 560 | 3.22 / 407.17 | 2 | 2 |
4 | 13 | 386.04 | 21 | 14.96 | 912 | 287 | 3.51 / 407.45 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.00 | 289 | 715 | 4.22 / 408.17 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.72 | 29 | 14.93 | 479 | 207 | 0.21 / 399.91 | 3 | 3 |
2 | 7 | 2007.88 | 52 | 14.88 | 3206 | 2481 | 2.69 / 402.39 | 2 | 2 |
3 | 13 | 1004.72 | 21 | 14.84 | 1808 | 563 | 3.25 / 402.95 | 2 | 3 |
4 | 13 | 390.20 | 21 | 14.97 | 919 | 289 | 3.54 / 403.24 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.00 | 284 | 703 | 4.24 / 403.95 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 29 | 14.95 | 473 | 205 | 0.21 / 395.54 | 3 | 3 |
2 | 7 | 2008.40 | 53 | 14.85 | 3188 | 2509 | 2.71 / 398.05 | 2 | 2 |
3 | 13 | 991.36 | 21 | 14.85 | 1783 | 556 | 3.27 / 398.61 | 2 | 3 |
4 | 13 | 385.96 | 21 | 14.96 | 911 | 286 | 3.56 / 398.90 | 2 | 4 |
5 | 13 | 21.00 | 21 | 15.03 | 322 | 102 | 3.66 / 399.00 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.99 | 285 | 705 | 4.36 / 399.70 | 2 | 4 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 29 | 14.96 | 453 | 197 | 0.20 / 391.25 | 3 | 3 |
2 | 7 | 2004.28 | 53 | 14.88 | 3203 | 2526 | 2.72 / 393.78 | 2 | 2 |
3 | 13 | 1013.64 | 21 | 14.85 | 1817 | 567 | 3.29 / 394.34 | 2 | 3 |
4 | 13 | 398.64 | 21 | 14.97 | 934 | 294 | 3.58 / 394.64 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.00 | 284 | 703 | 4.29 / 395.34 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 29 | 14.96 | 453 | 197 | 0.20 / 386.97 | 3 | 3 |
2 | 7 | 2009.32 | 53 | 14.87 | 3206 | 2527 | 2.72 / 389.49 | 2 | 2 |
3 | 13 | 995.24 | 21 | 14.85 | 1791 | 559 | 3.28 / 390.05 | 2 | 3 |
4 | 13 | 378.32 | 21 | 14.98 | 902 | 284 | 3.57 / 390.34 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.01 | 290 | 718 | 4.28 / 391.05 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 29 | 14.97 | 451 | 196 | 0.20 / 382.69 | 3 | 3 |
2 | 7 | 2004.92 | 53 | 14.88 | 3203 | 2526 | 2.72 / 385.22 | 2 | 2 |
3 | 13 | 1001.52 | 21 | 14.86 | 1804 | 563 | 3.28 / 385.78 | 2 | 3 |
4 | 13 | 386.56 | 21 | 14.97 | 917 | 288 | 3.57 / 386.07 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.02 | 282 | 699 | 4.27 / 386.77 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 29 | 14.97 | 440 | 191 | 0.19 / 378.48 | 3 | 3 |
2 | 7 | 2004.36 | 53 | 14.89 | 3194 | 2521 | 2.71 / 381.00 | 2 | 2 |
3 | 13 | 897.12 | 21 | 14.89 | 1655 | 518 | 3.23 / 381.52 | 2 | 3 |
4 | 13 | 316.00 | 21 | 14.99 | 803 | 253 | 3.48 / 381.77 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.03 | 293 | 727 | 4.21 / 382.50 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 29 | 14.96 | 473 | 205 | 0.21 / 374.04 | 3 | 3 |
2 | 7 | 2010.68 | 53 | 14.88 | 3206 | 2528 | 2.73 / 376.57 | 2 | 2 |
3 | 13 | 897.76 | 21 | 14.89 | 1663 | 520 | 3.25 / 377.09 | 2 | 3 |
4 | 13 | 322.12 | 21 | 15.01 | 819 | 258 | 3.51 / 377.35 | 2 | 3 |
5 | 13 | 17.96 | 21 | 15.05 | 315 | 100 | 3.61 / 377.45 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.02 | 288 | 714 | 4.33 / 378.16 | 2 | 3 |
7 | 14 | 0.00 | 30 | 15.00 | 284 | 128 | 4.45 / 378.29 | 3 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 29 | 14.97 | 447 | 194 | 0.19 / 369.63 | 3 | 3 |
2 | 7 | 2008.04 | 53 | 14.89 | 3203 | 2528 | 2.72 / 372.15 | 2 | 2 |
3 | 13 | 1017.04 | 21 | 14.88 | 1818 | 568 | 3.29 / 372.72 | 2 | 3 |
4 | 13 | 391.00 | 21 | 14.99 | 928 | 292 | 3.58 / 373.01 | 2 | 3 |
5 | 13 | 45.88 | 21 | 15.06 | 363 | 115 | 3.70 / 373.13 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.01 | 286 | 708 | 4.41 / 373.84 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 29 | 14.97 | 457 | 198 | 0.20 / 365.24 | 3 | 3 |
2 | 7 | 2002.68 | 53 | 14.89 | 3181 | 2510 | 2.71 / 367.75 | 2 | 2 |
3 | 13 | 1010.68 | 21 | 14.88 | 1816 | 567 | 3.28 / 368.32 | 2 | 3 |
4 | 13 | 400.20 | 21 | 14.99 | 935 | 294 | 3.57 / 368.61 | 2 | 3 |
5 | 13 | 21.88 | 21 | 15.06 | 326 | 103 | 3.67 / 368.71 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.03 | 290 | 719 | 4.39 / 369.43 | 2 | 3 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 29 | 14.99 | 454 | 197 | 0.20 / 360.87 | 3 | 3 |
2 | 7 | 2004.28 | 52 | 14.90 | 3201 | 2480 | 2.68 / 363.35 | 2 | 2 |
3 | 13 | 1014.12 | 21 | 14.86 | 1823 | 569 | 3.25 / 363.92 | 2 | 3 |
4 | 13 | 395.40 | 21 | 15.00 | 934 | 294 | 3.54 / 364.21 | 2 | 3 |
5 | 13 | 45.20 | 21 | 15.05 | 362 | 114 | 3.65 / 364.32 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.03 | 288 | 714 | 4.37 / 365.04 | 2 | 3 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 29 | 14.98 | 458 | 199 | 0.20 / 356.46 | 3 | 3 |
2 | 7 | 2001.92 | 53 | 14.91 | 3192 | 2522 | 2.72 / 358.98 | 2 | 2 |
3 | 13 | 994.92 | 21 | 14.89 | 1795 | 561 | 3.28 / 359.55 | 2 | 3 |
4 | 13 | 392.20 | 21 | 15.01 | 923 | 291 | 3.57 / 359.84 | 2 | 3 |
5 | 13 | 19.52 | 21 | 15.07 | 327 | 103 | 3.68 / 359.94 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.04 | 294 | 730 | 4.41 / 360.67 | 2 | 3 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 29 | 14.98 | 450 | 195 | 0.20 / 352.05 | 3 | 3 |
2 | 7 | 2003.44 | 53 | 14.90 | 3192 | 2521 | 2.72 / 354.57 | 2 | 2 |
3 | 13 | 1006.56 | 21 | 14.88 | 1811 | 566 | 3.28 / 355.13 | 2 | 3 |
4 | 13 | 395.88 | 21 | 15.00 | 932 | 294 | 3.58 / 355.43 | 2 | 3 |
5 | 13 | 36.84 | 21 | 15.06 | 354 | 112 | 3.69 / 355.54 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.02 | 293 | 726 | 4.41 / 356.26 | 2 | 4 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 29 | 14.99 | 463 | 201 | 0.20 / 347.65 | 3 | 3 |
2 | 7 | 2005.44 | 53 | 14.90 | 3191 | 2520 | 2.72 / 350.17 | 2 | 2 |
3 | 13 | 996.36 | 21 | 14.88 | 1795 | 561 | 3.28 / 350.73 | 2 | 3 |
4 | 13 | 390.72 | 21 | 15.01 | 929 | 293 | 3.57 / 351.03 | 2 | 3 |
5 | 13 | 20.96 | 21 | 15.08 | 323 | 102 | 3.68 / 351.13 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.04 | 290 | 720 | 4.40 / 351.85 | 2 | 4 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 29 | 15.00 | 456 | 198 | 0.20 / 343.31 | 3 | 3 |
2 | 7 | 2007.64 | 53 | 14.91 | 3195 | 2525 | 2.72 / 345.84 | 2 | 2 |
3 | 13 | 1011.24 | 21 | 14.87 | 1827 | 571 | 3.29 / 346.41 | 2 | 3 |
4 | 13 | 400.80 | 21 | 15.00 | 941 | 296 | 3.59 / 346.71 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.04 | 301 | 747 | 4.34 / 347.45 | 2 | 3 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 29 | 15.00 | 452 | 197 | 0.20 / 338.94 | 3 | 3 |
2 | 7 | 2004.84 | 52 | 14.91 | 3196 | 2478 | 2.67 / 341.41 | 2 | 2 |
3 | 13 | 1008.64 | 21 | 14.88 | 1814 | 567 | 3.24 / 341.98 | 2 | 3 |
4 | 13 | 399.48 | 21 | 15.02 | 937 | 296 | 3.54 / 342.28 | 2 | 3 |
5 | 13 | 21.92 | 21 | 15.09 | 332 | 105 | 3.64 / 342.38 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.05 | 296 | 735 | 4.38 / 343.12 | 2 | 4 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 29 | 15.01 | 479 | 209 | 0.21 / 334.65 | 3 | 3 |
2 | 7 | 2007.24 | 53 | 14.92 | 3188 | 2521 | 2.73 / 337.17 | 2 | 2 |
3 | 13 | 1000.52 | 21 | 14.90 | 1809 | 566 | 3.30 / 337.73 | 2 | 3 |
4 | 13 | 385.92 | 21 | 15.03 | 914 | 288 | 3.58 / 338.02 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.06 | 288 | 716 | 4.30 / 338.74 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 29 | 15.02 | 452 | 197 | 0.20 / 330.40 | 3 | 3 |
2 | 7 | 2008.40 | 53 | 14.90 | 3199 | 2526 | 2.72 / 332.93 | 2 | 2 |
3 | 13 | 898.32 | 21 | 14.92 | 1660 | 520 | 3.24 / 333.45 | 2 | 3 |
4 | 13 | 323.20 | 21 | 15.03 | 820 | 259 | 3.50 / 333.71 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.07 | 294 | 731 | 4.23 / 334.44 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 29 | 15.03 | 456 | 199 | 0.20 / 326.15 | 3 | 3 |
2 | 7 | 2006.88 | 53 | 14.92 | 3199 | 2530 | 2.73 / 328.68 | 2 | 2 |
3 | 13 | 1009.44 | 21 | 14.90 | 1811 | 567 | 3.30 / 329.25 | 2 | 3 |
4 | 13 | 282.48 | 21 | 15.06 | 753 | 238 | 3.53 / 329.48 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.08 | 290 | 722 | 4.25 / 330.21 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 29 | 15.03 | 457 | 199 | 0.20 / 321.83 | 3 | 3 |
2 | 7 | 2003.68 | 53 | 14.92 | 3199 | 2530 | 2.73 / 324.36 | 2 | 2 |
3 | 13 | 1006.72 | 21 | 14.91 | 1807 | 566 | 3.29 / 324.93 | 2 | 3 |
4 | 13 | 393.96 | 21 | 15.03 | 927 | 293 | 3.59 / 325.22 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.08 | 294 | 732 | 4.32 / 325.95 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 29 | 15.01 | 490 | 213 | 0.21 / 317.52 | 3 | 3 |
2 | 7 | 2004.36 | 53 | 14.93 | 3200 | 2532 | 2.75 / 320.06 | 2 | 2 |
3 | 13 | 1002.88 | 21 | 14.91 | 1809 | 566 | 3.31 / 320.62 | 2 | 3 |
4 | 13 | 384.72 | 21 | 15.06 | 917 | 290 | 3.60 / 320.91 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.10 | 289 | 720 | 4.32 / 321.63 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 29 | 15.04 | 488 | 213 | 0.21 / 313.17 | 3 | 3 |
2 | 7 | 2006.48 | 53 | 14.91 | 3199 | 2528 | 2.74 / 315.69 | 2 | 2 |
3 | 13 | 1006.72 | 21 | 14.90 | 1814 | 568 | 3.31 / 316.26 | 2 | 3 |
4 | 13 | 392.00 | 21 | 15.03 | 933 | 294 | 3.60 / 316.56 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.07 | 303 | 753 | 4.36 / 317.31 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 29 | 15.05 | 490 | 214 | 0.21 / 308.84 | 3 | 3 |
2 | 7 | 2008.32 | 53 | 14.92 | 3200 | 2530 | 2.74 / 311.37 | 2 | 2 |
3 | 13 | 992.80 | 21 | 14.92 | 1799 | 564 | 3.31 / 311.94 | 2 | 3 |
4 | 13 | 371.40 | 21 | 15.05 | 895 | 283 | 3.59 / 312.22 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.10 | 294 | 733 | 4.32 / 312.95 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 29 | 15.06 | 488 | 213 | 0.21 / 304.62 | 3 | 3 |
2 | 7 | 2004.08 | 53 | 14.92 | 3169 | 2506 | 2.72 / 307.12 | 2 | 2 |
3 | 13 | 880.84 | 21 | 14.94 | 1639 | 514 | 3.23 / 307.64 | 2 | 3 |
4 | 13 | 305.40 | 21 | 15.07 | 789 | 250 | 3.48 / 307.89 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.10 | 298 | 742 | 4.23 / 308.63 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 29 | 15.06 | 482 | 211 | 0.21 / 300.27 | 3 | 3 |
2 | 7 | 2003.40 | 53 | 14.93 | 3202 | 2534 | 2.74 / 302.81 | 2 | 2 |
3 | 13 | 1008.32 | 21 | 14.93 | 1818 | 570 | 3.31 / 303.38 | 2 | 3 |
4 | 13 | 395.12 | 21 | 15.07 | 932 | 295 | 3.61 / 303.67 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.11 | 294 | 733 | 4.34 / 304.41 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 29 | 15.05 | 482 | 210 | 0.21 / 295.95 | 3 | 3 |
2 | 7 | 2003.76 | 53 | 14.93 | 3189 | 2523 | 2.73 / 298.48 | 2 | 2 |
3 | 13 | 1004.12 | 21 | 14.93 | 1814 | 569 | 3.30 / 299.04 | 2 | 3 |
4 | 13 | 374.12 | 21 | 15.07 | 901 | 285 | 3.59 / 299.33 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.11 | 294 | 733 | 4.32 / 300.06 | 2 | 3 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 29 | 15.07 | 481 | 210 | 0.21 / 291.68 | 3 | 3 |
2 | 7 | 2003.04 | 52 | 14.94 | 3199 | 2485 | 2.70 / 294.16 | 2 | 2 |
3 | 13 | 995.36 | 21 | 14.93 | 1799 | 564 | 3.26 / 294.73 | 2 | 3 |
4 | 13 | 378.76 | 21 | 15.07 | 906 | 287 | 3.55 / 295.01 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.11 | 292 | 728 | 4.27 / 295.74 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 29 | 15.06 | 470 | 205 | 0.21 / 287.44 | 3 | 3 |
2 | 7 | 2012.20 | 53 | 14.93 | 3209 | 2539 | 2.74 / 289.98 | 2 | 2 |
3 | 13 | 893.92 | 21 | 14.95 | 1655 | 520 | 3.26 / 290.50 | 2 | 3 |
4 | 13 | 306.48 | 21 | 15.09 | 794 | 252 | 3.52 / 290.75 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.12 | 289 | 721 | 4.24 / 291.47 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 29 | 15.06 | 479 | 209 | 0.21 / 283.12 | 3 | 3 |
2 | 7 | 2003.80 | 53 | 14.92 | 3188 | 2521 | 2.73 / 285.65 | 2 | 2 |
3 | 13 | 999.36 | 21 | 14.93 | 1808 | 567 | 3.30 / 286.21 | 2 | 3 |
4 | 13 | 382.36 | 21 | 15.06 | 919 | 291 | 3.59 / 286.50 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.12 | 292 | 728 | 4.32 / 287.23 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 29 | 15.08 | 483 | 211 | 0.21 / 278.87 | 3 | 3 |
2 | 7 | 2007.72 | 53 | 14.92 | 3200 | 2530 | 2.74 / 281.40 | 2 | 2 |
3 | 13 | 889.24 | 21 | 14.95 | 1654 | 519 | 3.26 / 281.92 | 2 | 3 |
4 | 13 | 321.08 | 21 | 15.09 | 821 | 260 | 3.52 / 282.18 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.12 | 296 | 738 | 4.26 / 282.92 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 29 | 15.09 | 482 | 211 | 0.21 / 274.55 | 3 | 3 |
2 | 7 | 2005.72 | 53 | 14.94 | 3198 | 2532 | 2.74 / 277.08 | 2 | 2 |
3 | 13 | 992.68 | 21 | 14.95 | 1795 | 564 | 3.31 / 277.64 | 2 | 3 |
4 | 13 | 371.20 | 21 | 15.09 | 893 | 283 | 3.59 / 277.93 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.13 | 292 | 729 | 4.32 / 278.66 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 29 | 15.08 | 454 | 199 | 0.20 / 270.21 | 3 | 3 |
2 | 7 | 2010.28 | 53 | 14.92 | 3203 | 2533 | 2.73 / 272.74 | 2 | 2 |
3 | 13 | 1005.88 | 21 | 14.94 | 1819 | 571 | 3.30 / 273.32 | 2 | 3 |
4 | 13 | 376.20 | 21 | 15.08 | 901 | 285 | 3.59 / 273.60 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.13 | 295 | 736 | 4.32 / 274.34 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.32 | 29 | 15.08 | 489 | 214 | 0.21 / 265.96 | 3 | 3 |
2 | 7 | 2007.24 | 53 | 14.92 | 3203 | 2533 | 2.75 / 268.50 | 2 | 2 |
3 | 13 | 1015.20 | 21 | 14.91 | 1824 | 571 | 3.32 / 269.07 | 2 | 3 |
4 | 13 | 276.32 | 21 | 15.11 | 742 | 235 | 3.55 / 269.30 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.12 | 285 | 711 | 4.26 / 270.01 | 2 | 2 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 29 | 15.09 | 497 | 217 | 0.22 / 261.70 | 3 | 3 |
2 | 7 | 2004.96 | 53 | 14.93 | 3194 | 2527 | 2.74 / 264.22 | 2 | 2 |
3 | 13 | 996.40 | 21 | 14.93 | 1799 | 564 | 3.31 / 264.79 | 2 | 3 |
4 | 13 | 269.84 | 21 | 15.12 | 730 | 232 | 3.54 / 265.02 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.14 | 292 | 729 | 4.27 / 265.75 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 29 | 15.06 | 495 | 216 | 0.22 / 257.35 | 3 | 3 |
2 | 7 | 2004.44 | 52 | 14.95 | 3208 | 2494 | 2.71 / 259.85 | 2 | 2 |
3 | 13 | 1000.12 | 21 | 14.95 | 1818 | 571 | 3.28 / 260.42 | 2 | 3 |
4 | 13 | 376.80 | 21 | 15.10 | 925 | 293 | 3.57 / 260.71 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.13 | 307 | 766 | 4.34 / 261.48 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.68 | 29 | 15.08 | 488 | 213 | 0.21 / 253.05 | 3 | 3 |
2 | 7 | 2012.92 | 53 | 14.93 | 3204 | 2535 | 2.75 / 255.58 | 2 | 2 |
3 | 13 | 896.52 | 21 | 14.97 | 1665 | 523 | 3.27 / 256.11 | 2 | 3 |
4 | 13 | 325.80 | 21 | 15.10 | 824 | 261 | 3.53 / 256.37 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.13 | 309 | 771 | 4.30 / 257.14 | 2 | 3 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 29 | 15.08 | 465 | 203 | 0.20 / 248.79 | 3 | 3 |
2 | 7 | 2003.92 | 53 | 14.94 | 3198 | 2532 | 2.74 / 251.32 | 2 | 2 |
3 | 13 | 890.24 | 21 | 14.97 | 1650 | 519 | 3.25 / 251.84 | 2 | 3 |
4 | 13 | 309.60 | 21 | 15.11 | 803 | 255 | 3.51 / 252.09 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.13 | 296 | 739 | 4.25 / 252.83 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 29 | 15.08 | 461 | 202 | 0.20 / 244.56 | 3 | 3 |
2 | 7 | 2002.28 | 52 | 14.94 | 3210 | 2494 | 2.70 / 247.05 | 2 | 2 |
3 | 13 | 1005.16 | 21 | 14.93 | 1813 | 568 | 3.26 / 247.62 | 2 | 3 |
4 | 13 | 269.36 | 21 | 15.12 | 734 | 233 | 3.50 / 247.85 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.14 | 294 | 734 | 4.23 / 248.59 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.88 | 29 | 15.10 | 454 | 199 | 0.20 / 240.23 | 3 | 3 |
2 | 7 | 2007.80 | 53 | 14.94 | 3200 | 2534 | 2.73 / 242.77 | 2 | 2 |
3 | 13 | 998.12 | 21 | 14.95 | 1796 | 564 | 3.30 / 243.33 | 2 | 3 |
4 | 13 | 380.88 | 21 | 15.11 | 912 | 289 | 3.59 / 243.62 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.14 | 294 | 734 | 4.32 / 244.35 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 29 | 15.11 | 451 | 198 | 0.20 / 235.85 | 3 | 3 |
2 | 7 | 2008.64 | 53 | 14.96 | 3203 | 2540 | 2.74 / 238.39 | 2 | 2 |
3 | 13 | 1005.76 | 21 | 14.97 | 1817 | 571 | 3.31 / 238.96 | 2 | 3 |
4 | 13 | 272.40 | 21 | 15.15 | 741 | 236 | 3.54 / 239.20 | 2 | 3 |
5 | 13 | 26.12 | 21 | 15.19 | 336 | 107 | 3.65 / 239.31 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.15 | 291 | 727 | 4.38 / 240.03 | 2 | 4 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 29 | 15.11 | 466 | 204 | 0.20 / 231.66 | 3 | 3 |
2 | 7 | 2003.00 | 52 | 14.95 | 3194 | 2483 | 2.69 / 234.14 | 2 | 2 |
3 | 13 | 891.96 | 21 | 14.99 | 1659 | 522 | 3.21 / 234.66 | 2 | 3 |
4 | 13 | 313.84 | 21 | 15.12 | 806 | 256 | 3.47 / 234.92 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.15 | 294 | 735 | 4.20 / 235.66 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 29 | 15.11 | 466 | 204 | 0.20 / 227.33 | 3 | 3 |
2 | 7 | 2009.80 | 53 | 14.97 | 3215 | 2551 | 2.76 / 229.88 | 2 | 2 |
3 | 13 | 1016.24 | 21 | 14.97 | 1825 | 574 | 3.33 / 230.45 | 2 | 2 |
4 | 13 | 287.60 | 21 | 15.15 | 763 | 243 | 3.57 / 230.69 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.16 | 304 | 760 | 4.33 / 231.45 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.76 | 29 | 15.11 | 500 | 219 | 0.22 / 223.01 | 3 | 3 |
2 | 7 | 2001.68 | 53 | 14.95 | 3195 | 2532 | 2.75 / 225.54 | 2 | 2 |
3 | 13 | 981.88 | 21 | 14.98 | 1781 | 560 | 3.31 / 226.10 | 2 | 3 |
4 | 13 | 355.84 | 21 | 15.12 | 876 | 278 | 3.59 / 226.38 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.16 | 297 | 743 | 4.33 / 227.12 | 2 | 3 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 29 | 15.10 | 458 | 201 | 0.20 / 218.68 | 3 | 3 |
2 | 7 | 2008.40 | 52 | 14.96 | 3206 | 2494 | 2.69 / 221.18 | 2 | 2 |
3 | 13 | 995.60 | 21 | 14.97 | 1802 | 566 | 3.26 / 221.74 | 2 | 3 |
4 | 13 | 366.20 | 21 | 15.13 | 891 | 283 | 3.54 / 222.03 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.16 | 305 | 763 | 4.31 / 222.79 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 29 | 15.12 | 455 | 200 | 0.20 / 214.34 | 3 | 3 |
2 | 7 | 2003.92 | 53 | 14.96 | 3181 | 2522 | 2.72 / 216.87 | 2 | 2 |
3 | 13 | 888.88 | 21 | 15.01 | 1644 | 518 | 3.24 / 217.38 | 2 | 3 |
4 | 13 | 309.76 | 21 | 15.15 | 806 | 256 | 3.50 / 217.64 | 2 | 3 |
5 | 13 | 29.20 | 21 | 15.20 | 345 | 110 | 3.61 / 217.75 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.15 | 293 | 732 | 4.34 / 218.48 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.36 | 28 | 15.13 | 480 | 203 | 0.20 / 210.01 | 3 | 3 |
2 | 7 | 2007.24 | 53 | 14.97 | 3205 | 2543 | 2.75 / 212.55 | 2 | 2 |
3 | 13 | 1004.88 | 21 | 14.99 | 1813 | 571 | 3.32 / 213.12 | 2 | 3 |
4 | 13 | 372.76 | 21 | 15.14 | 898 | 286 | 3.60 / 213.41 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.18 | 295 | 739 | 4.34 / 214.14 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 28 | 15.12 | 449 | 190 | 0.19 / 205.73 | 3 | 3 |
2 | 7 | 2004.00 | 52 | 14.97 | 3199 | 2490 | 2.68 / 208.22 | 2 | 2 |
3 | 13 | 1003.44 | 21 | 14.99 | 1810 | 570 | 3.25 / 208.79 | 2 | 3 |
4 | 13 | 383.76 | 21 | 15.13 | 919 | 292 | 3.54 / 209.08 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.17 | 288 | 721 | 4.26 / 209.80 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 28 | 15.13 | 445 | 189 | 0.19 / 201.42 | 3 | 3 |
2 | 7 | 2004.56 | 53 | 14.97 | 3181 | 2524 | 2.71 / 203.95 | 2 | 2 |
3 | 13 | 996.48 | 21 | 14.99 | 1804 | 568 | 3.28 / 204.51 | 2 | 3 |
4 | 13 | 386.88 | 21 | 15.13 | 920 | 292 | 3.57 / 204.81 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.17 | 293 | 733 | 4.31 / 205.54 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 28 | 15.13 | 463 | 196 | 0.20 / 197.26 | 3 | 3 |
2 | 7 | 2006.00 | 52 | 14.99 | 3200 | 2494 | 2.69 / 199.75 | 2 | 2 |
3 | 13 | 882.32 | 21 | 15.03 | 1638 | 517 | 3.21 / 200.27 | 2 | 3 |
4 | 13 | 305.92 | 21 | 15.17 | 789 | 251 | 3.46 / 200.52 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.19 | 286 | 717 | 4.18 / 201.23 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.72 | 28 | 15.13 | 470 | 199 | 0.20 / 192.86 | 3 | 3 |
2 | 7 | 2003.36 | 52 | 14.98 | 3205 | 2497 | 2.70 / 195.36 | 2 | 2 |
3 | 13 | 1004.88 | 21 | 14.99 | 1807 | 569 | 3.26 / 195.92 | 2 | 3 |
4 | 13 | 377.48 | 21 | 15.17 | 903 | 288 | 3.55 / 196.21 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.18 | 286 | 716 | 4.27 / 196.93 | 2 | 3 |
6 | 14 | 0.16 | 30 | 15.17 | 287 | 131 | 4.40 / 197.06 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 28 | 15.14 | 483 | 205 | 0.20 / 188.53 | 3 | 3 |
2 | 7 | 2003.52 | 53 | 14.97 | 3201 | 2540 | 2.74 / 191.07 | 2 | 2 |
3 | 13 | 876.56 | 21 | 15.04 | 1632 | 515 | 3.26 / 191.58 | 2 | 3 |
4 | 13 | 298.32 | 21 | 15.17 | 780 | 248 | 3.51 / 191.83 | 2 | 3 |
5 | 13 | 25.20 | 21 | 15.23 | 331 | 106 | 3.61 / 191.94 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.20 | 288 | 722 | 4.34 / 192.66 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 28 | 15.13 | 479 | 203 | 0.20 / 184.28 | 3 | 3 |
2 | 7 | 2007.68 | 53 | 14.99 | 3194 | 2538 | 2.74 / 186.81 | 2 | 2 |
3 | 13 | 901.64 | 21 | 15.04 | 1670 | 527 | 3.27 / 187.34 | 2 | 3 |
4 | 13 | 311.80 | 21 | 15.17 | 804 | 256 | 3.52 / 187.60 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.18 | 290 | 726 | 4.25 / 188.32 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 28 | 15.14 | 472 | 200 | 0.20 / 179.89 | 3 | 3 |
2 | 7 | 2001.84 | 53 | 14.98 | 3194 | 2536 | 2.74 / 182.42 | 2 | 2 |
3 | 13 | 996.44 | 21 | 15.01 | 1806 | 569 | 3.31 / 182.99 | 2 | 3 |
4 | 13 | 264.04 | 21 | 15.18 | 735 | 234 | 3.54 / 183.23 | 2 | 3 |
5 | 13 | 20.24 | 21 | 15.23 | 325 | 104 | 3.64 / 183.33 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.19 | 296 | 742 | 4.39 / 184.07 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 28 | 15.15 | 468 | 199 | 0.20 / 175.59 | 3 | 3 |
2 | 7 | 2006.80 | 53 | 14.98 | 3201 | 2541 | 2.74 / 178.13 | 2 | 2 |
3 | 13 | 1003.12 | 21 | 15.02 | 1813 | 572 | 3.31 / 178.70 | 2 | 3 |
4 | 13 | 272.04 | 21 | 15.18 | 741 | 236 | 3.55 / 178.94 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.19 | 298 | 747 | 4.29 / 179.69 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 28 | 15.15 | 480 | 204 | 0.20 / 171.24 | 3 | 3 |
2 | 7 | 2005.56 | 53 | 14.98 | 3199 | 2540 | 2.74 / 173.78 | 2 | 2 |
3 | 13 | 984.04 | 21 | 15.03 | 1786 | 564 | 3.31 / 174.34 | 2 | 3 |
4 | 13 | 357.96 | 21 | 15.16 | 880 | 280 | 3.59 / 174.62 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.20 | 308 | 772 | 4.36 / 175.39 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.24 | 28 | 15.16 | 487 | 207 | 0.21 / 166.96 | 3 | 3 |
2 | 7 | 2002.08 | 53 | 14.99 | 3202 | 2544 | 2.75 / 169.50 | 2 | 2 |
3 | 13 | 993.88 | 21 | 15.02 | 1797 | 567 | 3.32 / 170.07 | 2 | 3 |
4 | 13 | 257.48 | 21 | 15.20 | 720 | 230 | 3.55 / 170.30 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.20 | 293 | 735 | 4.28 / 171.03 | 2 | 3 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 28 | 15.16 | 452 | 192 | 0.19 / 162.63 | 3 | 3 |
2 | 7 | 2005.28 | 53 | 14.98 | 3191 | 2533 | 2.73 / 165.16 | 2 | 2 |
3 | 13 | 992.44 | 21 | 15.02 | 1793 | 566 | 3.29 / 165.73 | 2 | 3 |
4 | 13 | 370.04 | 21 | 15.17 | 891 | 284 | 3.57 / 166.01 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.20 | 294 | 737 | 4.31 / 166.75 | 2 | 3 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 28 | 15.15 | 480 | 204 | 0.20 / 158.39 | 3 | 3 |
2 | 7 | 2002.92 | 52 | 15.00 | 3192 | 2490 | 2.69 / 160.88 | 2 | 2 |
3 | 13 | 974.80 | 21 | 15.03 | 1769 | 558 | 3.25 / 161.43 | 2 | 3 |
4 | 13 | 352.32 | 21 | 15.17 | 875 | 279 | 3.53 / 161.71 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.21 | 289 | 725 | 4.26 / 162.44 | 2 | 2 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 28 | 15.15 | 477 | 202 | 0.20 / 154.05 | 3 | 3 |
2 | 7 | 2004.40 | 53 | 15.00 | 3188 | 2534 | 2.74 / 156.59 | 2 | 2 |
3 | 13 | 997.08 | 21 | 15.03 | 1795 | 567 | 3.30 / 157.15 | 2 | 3 |
4 | 13 | 379.32 | 21 | 15.18 | 906 | 289 | 3.59 / 157.44 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.21 | 295 | 740 | 4.33 / 158.18 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 28 | 15.15 | 479 | 203 | 0.20 / 149.80 | 3 | 3 |
2 | 7 | 2002.92 | 53 | 14.98 | 3191 | 2533 | 2.74 / 152.33 | 2 | 2 |
3 | 13 | 972.12 | 21 | 15.03 | 1762 | 556 | 3.29 / 152.89 | 2 | 3 |
4 | 13 | 255.36 | 21 | 15.20 | 719 | 230 | 3.52 / 153.12 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.21 | 291 | 730 | 4.25 / 153.85 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.36 | 28 | 15.17 | 484 | 206 | 0.21 / 145.49 | 3 | 3 |
2 | 7 | 2004.48 | 53 | 14.99 | 3186 | 2531 | 2.74 / 148.02 | 2 | 2 |
3 | 13 | 987.28 | 21 | 15.01 | 1782 | 562 | 3.30 / 148.58 | 2 | 3 |
4 | 13 | 357.48 | 21 | 15.18 | 871 | 278 | 3.58 / 148.86 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.21 | 294 | 738 | 4.31 / 149.60 | 2 | 2 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 28 | 15.16 | 477 | 202 | 0.20 / 141.27 | 3 | 3 |
2 | 7 | 2004.12 | 52 | 15.00 | 3191 | 2489 | 2.69 / 143.76 | 2 | 2 |
3 | 13 | 998.32 | 21 | 15.03 | 1798 | 568 | 3.26 / 144.33 | 2 | 3 |
4 | 13 | 251.00 | 21 | 15.20 | 703 | 224 | 3.48 / 144.56 | 2 | 2 |
5 | 8 | 0.08 | 165 | 15.23 | 290 | 729 | 4.21 / 145.28 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 28 | 15.17 | 483 | 205 | 0.21 / 137.01 | 3 | 3 |
2 | 7 | 2002.44 | 52 | 15.00 | 3190 | 2488 | 2.69 / 139.49 | 2 | 2 |
3 | 13 | 979.24 | 21 | 15.05 | 1778 | 562 | 3.26 / 140.06 | 2 | 3 |
4 | 13 | 362.16 | 21 | 15.19 | 886 | 283 | 3.54 / 140.34 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.21 | 292 | 733 | 4.27 / 141.07 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.84 | 28 | 15.18 | 479 | 204 | 0.20 / 132.71 | 3 | 3 |
2 | 7 | 2006.08 | 53 | 15.02 | 3207 | 2553 | 2.76 / 135.26 | 2 | 2 |
3 | 13 | 1005.72 | 21 | 15.05 | 1813 | 573 | 3.33 / 135.84 | 2 | 3 |
4 | 13 | 263.36 | 21 | 15.21 | 723 | 231 | 3.56 / 136.07 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.24 | 292 | 734 | 4.29 / 136.80 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 28 | 15.17 | 484 | 206 | 0.21 / 128.47 | 3 | 3 |
2 | 7 | 2002.64 | 53 | 15.01 | 3194 | 2541 | 2.75 / 131.01 | 2 | 2 |
3 | 13 | 874.72 | 21 | 15.07 | 1630 | 516 | 3.26 / 131.53 | 2 | 3 |
4 | 13 | 284.72 | 21 | 15.21 | 756 | 241 | 3.50 / 131.77 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.23 | 293 | 736 | 4.24 / 132.51 | 2 | 2 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 28 | 15.19 | 466 | 198 | 0.20 / 124.20 | 3 | 3 |
2 | 7 | 2006.80 | 53 | 15.00 | 3191 | 2537 | 2.74 / 126.73 | 2 | 2 |
3 | 13 | 1001.96 | 21 | 15.03 | 1808 | 571 | 3.31 / 127.31 | 2 | 3 |
4 | 13 | 257.68 | 21 | 15.20 | 720 | 230 | 3.54 / 127.54 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.22 | 291 | 731 | 4.27 / 128.27 | 2 | 2 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 28 | 15.19 | 504 | 214 | 0.21 / 119.99 | 3 | 3 |
2 | 7 | 2002.20 | 52 | 15.01 | 3188 | 2488 | 2.70 / 122.48 | 2 | 2 |
3 | 13 | 990.00 | 21 | 15.02 | 1787 | 564 | 3.27 / 123.05 | 2 | 3 |
4 | 13 | 249.08 | 21 | 15.23 | 704 | 225 | 3.49 / 123.27 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.22 | 290 | 728 | 4.22 / 124.00 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 28 | 15.19 | 459 | 195 | 0.20 / 115.70 | 3 | 3 |
2 | 7 | 2008.20 | 53 | 15.03 | 3194 | 2544 | 2.74 / 118.25 | 2 | 2 |
3 | 13 | 871.36 | 21 | 15.10 | 1628 | 516 | 3.26 / 118.76 | 2 | 3 |
4 | 13 | 283.64 | 21 | 15.23 | 765 | 245 | 3.50 / 119.01 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.25 | 307 | 772 | 4.27 / 119.78 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 28 | 15.20 | 494 | 210 | 0.21 / 111.33 | 3 | 3 |
2 | 7 | 2003.80 | 53 | 15.04 | 3191 | 2544 | 2.75 / 113.87 | 2 | 2 |
3 | 13 | 875.92 | 21 | 15.10 | 1637 | 519 | 3.27 / 114.39 | 2 | 3 |
4 | 13 | 288.44 | 21 | 15.23 | 768 | 246 | 3.52 / 114.64 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.25 | 292 | 735 | 4.25 / 115.37 | 2 | 2 |
6 | 14 | -0.04 | 30 | 15.23 | 292 | 133 | 4.39 / 115.51 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.24 | 28 | 15.21 | 486 | 207 | 0.21 / 107.00 | 3 | 3 |
2 | 7 | 2004.60 | 53 | 15.02 | 3199 | 2547 | 2.75 / 109.55 | 2 | 2 |
3 | 13 | 976.88 | 21 | 15.07 | 1772 | 561 | 3.31 / 110.11 | 2 | 3 |
4 | 13 | 339.64 | 21 | 15.24 | 848 | 271 | 3.59 / 110.38 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.25 | 295 | 742 | 4.33 / 111.12 | 2 | 3 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 28 | 15.20 | 488 | 208 | 0.21 / 102.78 | 3 | 3 |
2 | 7 | 2003.04 | 52 | 15.05 | 3186 | 2493 | 2.70 / 105.27 | 2 | 2 |
3 | 13 | 884.96 | 21 | 15.11 | 1646 | 522 | 3.22 / 105.79 | 2 | 3 |
4 | 13 | 301.12 | 21 | 15.24 | 788 | 252 | 3.48 / 106.04 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.26 | 297 | 748 | 4.22 / 106.79 | 2 | 2 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 28 | 15.21 | 476 | 203 | 0.20 / 98.49 | 3 | 3 |
2 | 7 | 2002.00 | 53 | 15.05 | 3193 | 2547 | 2.75 / 101.03 | 2 | 2 |
3 | 13 | 982.56 | 21 | 15.08 | 1791 | 567 | 3.32 / 101.60 | 2 | 3 |
4 | 13 | 246.52 | 21 | 15.24 | 706 | 226 | 3.54 / 101.83 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.25 | 295 | 742 | 4.29 / 102.57 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 28 | 15.22 | 482 | 205 | 0.21 / 94.17 | 3 | 3 |
2 | 7 | 2004.36 | 52 | 15.05 | 3199 | 2504 | 2.71 / 96.68 | 2 | 2 |
3 | 13 | 1000.76 | 21 | 15.08 | 1805 | 572 | 3.28 / 97.25 | 2 | 3 |
4 | 13 | 376.68 | 21 | 15.23 | 912 | 292 | 3.57 / 97.54 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.26 | 296 | 745 | 4.32 / 98.28 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 28 | 15.22 | 485 | 207 | 0.21 / 89.82 | 3 | 3 |
2 | 7 | 2005.88 | 53 | 15.05 | 3203 | 2555 | 2.76 / 92.37 | 2 | 2 |
3 | 13 | 990.36 | 21 | 15.08 | 1798 | 569 | 3.33 / 92.94 | 2 | 3 |
4 | 13 | 365.84 | 21 | 15.22 | 892 | 285 | 3.62 / 93.23 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.26 | 294 | 740 | 4.36 / 93.97 | 2 | 2 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 28 | 15.22 | 488 | 208 | 0.21 / 85.53 | 3 | 3 |
2 | 7 | 2003.28 | 53 | 15.05 | 3203 | 2555 | 2.76 / 88.08 | 2 | 2 |
3 | 13 | 982.08 | 21 | 15.10 | 1783 | 565 | 3.33 / 88.65 | 2 | 3 |
4 | 13 | 244.68 | 21 | 15.27 | 705 | 226 | 3.55 / 88.87 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.27 | 293 | 738 | 4.29 / 89.61 | 2 | 2 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 28 | 15.22 | 494 | 211 | 0.21 / 81.28 | 2 | 3 |
2 | 7 | 2004.32 | 52 | 15.06 | 3195 | 2502 | 2.71 / 83.78 | 2 | 2 |
3 | 13 | 986.16 | 21 | 15.11 | 1788 | 567 | 3.28 / 84.35 | 2 | 3 |
4 | 13 | 238.72 | 21 | 15.27 | 700 | 224 | 3.50 / 84.57 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.28 | 296 | 746 | 4.25 / 85.32 | 2 | 2 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 28 | 15.22 | 482 | 205 | 0.21 / 77.00 | 2 | 3 |
2 | 7 | 2006.64 | 53 | 15.05 | 3197 | 2550 | 2.76 / 79.55 | 2 | 2 |
3 | 13 | 868.00 | 21 | 15.12 | 1626 | 516 | 3.27 / 80.07 | 2 | 3 |
4 | 13 | 277.08 | 21 | 15.25 | 753 | 241 | 3.51 / 80.31 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.28 | 301 | 759 | 4.27 / 81.07 | 2 | 2 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 28 | 15.21 | 480 | 204 | 0.20 / 72.72 | 2 | 3 |
2 | 7 | 2008.40 | 53 | 15.04 | 3196 | 2548 | 2.75 / 75.27 | 2 | 2 |
3 | 13 | 876.72 | 21 | 15.12 | 1647 | 523 | 3.27 / 75.79 | 2 | 3 |
4 | 13 | 279.68 | 21 | 15.25 | 775 | 248 | 3.52 / 76.04 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.27 | 301 | 758 | 4.28 / 76.80 | 2 | 2 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 28 | 15.22 | 476 | 203 | 0.20 / 68.42 | 3 | 3 |
2 | 7 | 2006.96 | 53 | 15.04 | 3188 | 2541 | 2.74 / 70.96 | 2 | 2 |
3 | 13 | 874.84 | 21 | 15.12 | 1636 | 519 | 3.26 / 71.48 | 2 | 3 |
4 | 13 | 273.48 | 21 | 15.26 | 754 | 242 | 3.51 / 71.72 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.26 | 314 | 791 | 4.30 / 72.51 | 2 | 3 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 28 | 15.21 | 492 | 210 | 0.21 / 64.16 | 3 | 3 |
2 | 7 | 2003.48 | 53 | 15.07 | 3190 | 2548 | 2.76 / 66.70 | 2 | 2 |
3 | 13 | 958.12 | 21 | 15.11 | 1759 | 558 | 3.32 / 67.26 | 2 | 3 |
4 | 13 | 222.96 | 21 | 15.27 | 672 | 215 | 3.53 / 67.48 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.28 | 294 | 741 | 4.27 / 68.22 | 2 | 3 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 28 | 15.22 | 472 | 201 | 0.20 / 59.81 | 3 | 3 |
2 | 7 | 2002.72 | 53 | 15.06 | 3189 | 2545 | 2.75 / 62.36 | 2 | 2 |
3 | 13 | 964.72 | 21 | 15.11 | 1775 | 563 | 3.31 / 62.92 | 2 | 3 |
4 | 13 | 327.68 | 21 | 15.25 | 846 | 271 | 3.58 / 63.19 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.27 | 300 | 756 | 4.34 / 63.95 | 2 | 3 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 28 | 15.23 | 482 | 206 | 0.21 / 55.46 | 3 | 3 |
2 | 7 | 2007.04 | 53 | 15.07 | 3199 | 2555 | 2.76 / 58.02 | 2 | 2 |
3 | 13 | 973.52 | 21 | 15.12 | 1773 | 563 | 3.32 / 58.58 | 2 | 3 |
4 | 13 | 349.36 | 21 | 15.25 | 873 | 280 | 3.60 / 58.86 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.28 | 298 | 751 | 4.35 / 59.61 | 2 | 2 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.20 | 28 | 15.24 | 498 | 213 | 0.21 / 51.10 | 3 | 3 |
2 | 7 | 2006.96 | 53 | 15.07 | 3205 | 2560 | 2.77 / 53.66 | 2 | 2 |
3 | 13 | 979.40 | 21 | 15.11 | 1784 | 566 | 3.34 / 54.23 | 2 | 3 |
4 | 13 | 349.32 | 21 | 15.24 | 873 | 279 | 3.62 / 54.51 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.28 | 296 | 746 | 4.36 / 55.25 | 2 | 3 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.44 | 27 | 15.24 | 489 | 201 | 0.20 / 46.82 | 3 | 3 |
2 | 7 | 2003.04 | 53 | 15.06 | 3201 | 2555 | 2.76 / 49.38 | 2 | 2 |
3 | 13 | 852.16 | 21 | 15.16 | 1612 | 513 | 3.27 / 49.89 | 2 | 3 |
4 | 13 | 255.20 | 21 | 15.27 | 730 | 234 | 3.50 / 50.12 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.29 | 304 | 767 | 4.27 / 50.89 | 2 | 3 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 27 | 15.24 | 467 | 192 | 0.19 / 42.41 | 3 | 3 |
2 | 7 | 2003.64 | 53 | 15.08 | 3207 | 2563 | 2.76 / 44.97 | 2 | 2 |
3 | 13 | 855.04 | 21 | 15.15 | 1618 | 515 | 3.27 / 45.48 | 2 | 3 |
4 | 13 | 285.36 | 21 | 15.28 | 774 | 248 | 3.52 / 45.73 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.29 | 298 | 752 | 4.27 / 46.48 | 2 | 2 |
6 | 14 | 0.08 | 30 | 15.27 | 297 | 136 | 4.41 / 46.62 | 2 | 3 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 27 | 15.25 | 467 | 192 | 0.19 / 38.07 | 3 | 3 |
2 | 7 | 2002.40 | 53 | 15.09 | 3201 | 2560 | 2.75 / 40.63 | 2 | 2 |
3 | 13 | 996.20 | 21 | 15.13 | 1825 | 580 | 3.33 / 41.21 | 2 | 3 |
4 | 13 | 244.84 | 21 | 15.29 | 715 | 230 | 3.56 / 41.44 | 2 | 2 |
5 | 8 | 0.12 | 165 | 15.30 | 305 | 770 | 4.33 / 42.21 | 2 | 3 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 27 | 15.25 | 472 | 194 | 0.19 / 33.74 | 3 | 3 |
2 | 7 | 2006.32 | 53 | 15.09 | 3213 | 2570 | 2.76 / 36.31 | 2 | 2 |
3 | 13 | 983.88 | 21 | 15.14 | 1798 | 572 | 3.34 / 36.88 | 2 | 3 |
4 | 13 | 237.40 | 21 | 15.30 | 703 | 226 | 3.56 / 37.10 | 2 | 2 |
5 | 8 | 0.08 | 165 | 15.30 | 308 | 778 | 4.34 / 37.88 | 2 | 3 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 27 | 15.24 | 482 | 198 | 0.20 / 29.44 | 3 | 3 |
2 | 7 | 2006.36 | 53 | 15.10 | 3201 | 2562 | 2.76 / 32.00 | 2 | 2 |
3 | 13 | 864.08 | 21 | 15.17 | 1640 | 522 | 3.28 / 32.52 | 2 | 3 |
4 | 13 | 271.80 | 21 | 15.29 | 758 | 243 | 3.53 / 32.77 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.30 | 308 | 778 | 4.30 / 33.54 | 2 | 3 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 27 | 15.25 | 482 | 198 | 0.20 / 25.00 | 3 | 3 |
2 | 7 | 2002.44 | 53 | 15.09 | 3209 | 2566 | 2.76 / 27.56 | 2 | 2 |
3 | 13 | 965.92 | 19 | 15.15 | 1778 | 512 | 3.28 / 28.07 | 2 | 3 |
4 | 13 | 354.44 | 19 | 15.28 | 884 | 257 | 3.53 / 28.33 | 2 | 3 |
5 | 13 | 18.36 | 19 | 15.34 | 347 | 101 | 3.63 / 28.43 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.30 | 320 | 808 | 4.44 / 29.24 | 2 | 3 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 26 | 15.26 | 494 | 196 | 0.20 / 20.70 | 3 | 3 |
2 | 10 | 1017.92 | 2 | 15.28 | 1904 | 58 | 0.25 / 20.76 | 2 | 3 |
3 | 7 | 2002.24 | 52 | 15.10 | 3189 | 2504 | 2.76 / 23.26 | 2 | 2 |
4 | 13 | 847.36 | 18 | 15.18 | 1617 | 442 | 3.20 / 23.70 | 2 | 3 |
5 | 13 | 280.76 | 18 | 15.30 | 765 | 211 | 3.41 / 23.91 | 2 | 3 |
6 | 13 | 25.28 | 18 | 15.34 | 353 | 97 | 3.51 / 24.01 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.30 | 311 | 785 | 4.29 / 24.80 | 2 | 2 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 25 | 15.27 | 495 | 189 | 0.19 / 16.36 | 3 | 3 |
2 | 10 | 1027.68 | 2 | 15.27 | 1917 | 59 | 0.25 / 16.41 | 2 | 2 |
3 | 7 | 2004.56 | 53 | 15.12 | 3207 | 2570 | 2.82 / 18.98 | 2 | 2 |
4 | 13 | 848.00 | 18 | 15.18 | 1613 | 441 | 3.26 / 19.43 | 2 | 3 |
5 | 13 | 280.28 | 18 | 15.31 | 762 | 210 | 3.47 / 19.64 | 2 | 2 |
6 | 13 | 25.28 | 18 | 15.34 | 348 | 96 | 3.56 / 19.73 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.30 | 306 | 772 | 4.34 / 20.50 | 2 | 3 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.56 | 26 | 15.26 | 489 | 194 | 0.19 / 12.80 | 3 | 3 |
2 | 7 | 1522.04 | 53 | 15.20 | 2539 | 2045 | 2.24 / 14.84 | 2 | 2 |
3 | 13 | 738.20 | 18 | 15.22 | 1446 | 396 | 2.64 / 15.24 | 2 | 2 |
4 | 13 | 161.20 | 18 | 15.34 | 583 | 161 | 2.80 / 15.40 | 2 | 2 |
5 | 8 | 0.08 | 165 | 15.32 | 304 | 768 | 3.57 / 16.17 | 2 | 3 |
Average= | 3.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 26 | 15.27 | 488 | 194 | 0.19 / 8.93 | 3 | 3 |
2 | 7 | 1521.16 | 74 | 14.98 | 2503 | 2775 | 2.97 / 11.71 | 2 | 3 |
3 | 13 | 118.36 | 18 | 15.34 | 501 | 138 | 3.11 / 11.84 | 2 | 2 |
4 | 8 | 0.12 | 165 | 15.32 | 300 | 758 | 3.87 / 12.60 | 2 | 3 |
Average= | 3.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 26 | 15.30 | 480 | 191 | 0.19 / 4.97 | 3 | 3 |
2 | 7 | 1522.20 | 75 | 14.99 | 2506 | 2817 | 3.01 / 7.78 | 2 | 3 |
3 | 13 | 218.72 | 18 | 15.32 | 668 | 184 | 3.19 / 7.97 | 2 | 2 |
4 | 8 | 0.16 | 165 | 15.34 | 304 | 769 | 3.96 / 8.74 | 2 | 3 |
Average= | 2.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 23 | 15.48 | 436 | 155 | 0.16 / 1.90 | 3 | 3 |
2 | 10 | 1025.68 | 3 | 15.34 | 1885 | 87 | 0.24 / 1.99 | 2 | 3 |
3 | 7 | 1004.64 | 74 | 15.18 | 1786 | 2006 | 2.25 / 3.99 | 2 | 3 |
4 | 8 | 0.04 | 165 | 15.37 | 309 | 784 | 3.03 / 4.77 | 2 | 3 |
Average= | 2.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 169.76 | 22 | 15.61 | 531 | 182 | 0.18 / 0.18 | 3 | 3 |
2 | 7 | 184.00 | 74 | 15.58 | 525 | 605 | 0.79 / 0.79 | 3 | 3 |
3 | 8 | 0.20 | 240 | 15.55 | 256 | 955 | 1.74 / 1.74 | 3 | 6 |
Average= | 1.74 (KJ/cycle) |