SIO Argo Site:
Pump Diagnostics Page   



Serial= 8814 WMO= 5906125

Return

←PreviousNext→

Cycle 188 GMT 11/12/2024 4:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 30 14.98 454 204 0.20 / 789.44 2 3
2 7 2003.56 53 14.85 3157 2485 2.69 / 791.92 2 2
3 13 1027.04 21 14.81 1797 559 3.25 / 792.48 2 7
4 13 280.40 21 14.99 716 225 3.47 / 792.71 2 3
5 8 0.24 175 15.04 262 690 4.16 / 793.39 2 3
Average= 4.20
(KJ/cycle)

Cycle 187 GMT 1/12/2024 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 30 14.99 455 205 0.20 / 785.28 2 3
2 7 2004.48 53 14.85 3149 2478 2.68 / 787.76 2 2
3 13 1024.36 21 14.82 1796 559 3.24 / 788.32 2 8
4 13 285.04 21 15.01 724 228 3.47 / 788.55 2 4
5 8 0.04 175 15.05 259 682 4.15 / 789.23 2 4
Average= 4.20
(KJ/cycle)

Cycle 186 GMT 21/11/2024 15:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 30 14.98 454 204 0.20 / 781.07 2 3
2 7 2003.96 53 14.86 3155 2485 2.69 / 783.56 2 2
3 13 1032.36 21 14.81 1800 560 3.25 / 784.12 2 5
4 13 413.08 21 14.97 910 286 3.53 / 784.40 2 5
5 8 0.20 175 15.05 257 677 4.21 / 785.08 2 3
Average= 4.20
(KJ/cycle)

Cycle 185 GMT 11/11/2024 20:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 30 14.99 456 205 0.21 / 776.89 2 3
2 7 2012.40 53 14.85 3170 2495 2.70 / 779.39 2 2
3 13 1040.48 21 14.81 1810 563 3.26 / 779.95 2 6
4 13 294.84 21 15.01 734 231 3.49 / 780.18 2 4
5 8 -0.04 175 15.05 260 685 4.18 / 780.87 2 3
Average= 4.20
(KJ/cycle)

Cycle 184 GMT 2/11/2024 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 30 14.99 455 205 0.20 / 772.74 2 3
2 7 2002.84 53 14.86 3145 2477 2.68 / 775.21 2 2
3 13 1030.32 21 14.83 1802 561 3.24 / 775.78 2 12
4 13 294.88 21 15.01 735 232 3.47 / 776.01 2 3
5 8 0.00 175 15.05 259 682 4.16 / 776.69 2 3
Average= 4.20
(KJ/cycle)

Cycle 183 GMT 23/10/2024 7:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 30 15.01 431 194 0.19 / 768.60 2 3
2 7 2012.08 52 14.85 3183 2458 2.65 / 771.06 2 2
3 13 1041.60 21 14.81 1812 564 3.22 / 771.62 2 4
4 13 299.40 21 15.01 736 232 3.45 / 771.85 2 4
5 8 0.12 175 15.05 258 680 4.13 / 772.53 2 3
Average= 4.20
(KJ/cycle)

Cycle 182 GMT 13/10/2024 12: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 30 15.00 450 202 0.20 / 764.35 2 3
2 7 2010.52 53 14.86 3170 2497 2.70 / 766.84 2 2
3 13 1036.40 21 14.81 1804 561 3.26 / 767.40 2 6
4 13 294.32 21 15.01 730 230 3.49 / 767.63 2 4
5 8 0.12 175 15.06 256 675 4.16 / 768.31 2 3
6 14 0.12 25 15.04 256 96 4.26 / 768.41 2 3
Average= 4.20
(KJ/cycle)

Cycle 181 GMT 3/10/2024 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 30 14.98 455 204 0.20 / 760.10 2 3
2 7 2003.80 53 14.86 3155 2485 2.69 / 762.58 2 2
3 13 1025.04 21 14.81 1784 555 3.24 / 763.14 2 5
4 13 285.36 21 15.01 716 226 3.47 / 763.36 2 3
5 8 0.20 175 15.05 259 682 4.15 / 764.05 2 2
6 14 0.20 25 15.02 260 98 4.25 / 764.14 2 3
Average= 4.20
(KJ/cycle)

Cycle 180 GMT 23/ 9/2024 22:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 30 14.99 457 206 0.21 / 755.86 2 3
2 7 2009.84 53 14.86 3181 2505 2.71 / 758.37 2 2
3 13 1020.28 21 14.84 1786 557 3.27 / 758.92 2 5
4 13 394.48 21 14.99 881 277 3.54 / 759.20 2 5
5 8 -0.04 175 15.05 263 693 4.24 / 759.89 2 3
Average= 4.20
(KJ/cycle)

Cycle 179 GMT 14/ 9/2024 3:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 30 14.99 459 206 0.21 / 751.55 2 3
2 7 2003.20 53 14.85 3163 2489 2.70 / 754.04 2 3
3 13 1157.12 21 14.80 1988 618 3.31 / 754.66 2 5
4 13 266.00 21 15.03 694 219 3.53 / 754.88 2 3
5 8 0.04 175 15.06 259 683 4.22 / 755.56 2 2
6 14 0.04 25 15.03 262 98 4.31 / 755.66 2 3
Average= 4.20
(KJ/cycle)

Cycle 178 GMT 4/ 9/2024 8:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.88 31 15.00 473 220 0.22 / 747.36 2 3
2 7 2011.48 53 14.87 3182 2508 2.73 / 749.86 2 2
3 13 1028.44 21 14.83 1804 562 3.29 / 750.43 2 3
4 13 294.48 21 15.01 734 231 3.52 / 750.66 2 4
5 8 0.24 175 15.06 260 685 4.21 / 751.34 2 3
Average= 4.20
(KJ/cycle)

Cycle 177 GMT 25/ 8/2024 14:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 30 14.99 472 212 0.21 / 743.13 2 3
2 7 2008.28 53 14.87 3168 2497 2.71 / 745.63 2 2
3 13 1043.16 21 14.82 1820 566 3.28 / 746.20 2 4
4 13 289.64 21 15.01 731 230 3.51 / 746.43 2 4
5 8 0.16 175 15.06 269 709 4.21 / 747.14 2 2
Average= 4.20
(KJ/cycle)

Cycle 176 GMT 15/ 8/2024 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 30 15.00 460 207 0.21 / 738.93 2 3
2 7 2002.60 53 14.88 3149 2483 2.69 / 741.41 2 2
3 13 1045.56 21 14.82 1819 566 3.26 / 741.98 2 8
4 13 308.84 21 15.02 759 239 3.50 / 742.22 2 4
5 8 0.20 175 15.06 267 704 4.20 / 742.92 2 3
Average= 4.20
(KJ/cycle)

Cycle 175 GMT 6/ 8/2024 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 30 15.00 467 210 0.21 / 734.65 2 3
2 7 2004.00 53 14.87 3163 2493 2.70 / 737.14 2 3
3 13 1031.80 21 14.83 1800 561 3.26 / 737.70 2 8
4 13 281.76 21 15.02 718 226 3.49 / 737.93 2 5
5 8 0.16 175 15.06 263 693 4.18 / 738.62 2 3
6 14 0.16 25 15.04 264 99 4.28 / 738.72 2 3
Average= 4.20
(KJ/cycle)

Cycle 174 GMT 27/ 7/2024 5:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 30 15.00 456 205 0.21 / 730.36 2 3
2 7 2004.76 53 14.87 3162 2492 2.70 / 732.85 2 3
3 13 1029.04 21 14.84 1802 562 3.26 / 733.42 2 5
4 13 292.52 21 15.02 735 232 3.49 / 733.65 2 4
5 8 -0.16 175 15.07 263 694 4.18 / 734.34 2 3
6 14 -0.16 25 15.05 262 99 4.28 / 734.44 2 4
Average= 4.20
(KJ/cycle)

Cycle 173 GMT 17/ 7/2024 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 30 15.00 430 193 0.19 / 725.98 2 3
2 7 2009.88 53 14.86 3161 2490 2.68 / 728.47 2 2
3 13 1036.64 21 14.83 1806 562 3.25 / 729.04 2 5
4 13 300.76 21 15.02 745 235 3.48 / 729.27 2 3
5 13 26.48 21 15.08 305 97 3.58 / 729.37 2 3
6 8 -0.12 175 15.05 263 693 4.27 / 730.06 2 3
7 14 -0.12 25 15.03 262 98 4.37 / 730.16 2 3
Average= 4.20
(KJ/cycle)

Cycle 172 GMT 7/ 7/2024 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 14.98 462 208 0.21 / 721.83 2 3
2 7 2004.28 53 14.87 3142 2476 2.68 / 724.31 2 2
3 13 1047.28 21 14.83 1825 568 3.25 / 724.88 2 4
4 13 296.60 21 15.02 740 233 3.49 / 725.11 2 4
5 8 0.12 175 15.07 258 680 4.17 / 725.79 2 3
Average= 4.20
(KJ/cycle)

Cycle 171 GMT 27/ 6/2024 21:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 30 15.00 425 191 0.19 / 717.65 2 3
2 7 2009.04 53 14.88 3169 2499 2.69 / 720.15 2 2
3 13 1027.48 21 14.83 1793 558 3.25 / 720.71 2 7
4 13 297.32 21 15.02 735 232 3.48 / 720.94 2 4
5 8 0.28 175 15.07 259 683 4.16 / 721.62 2 3
Average= 4.20
(KJ/cycle)

Cycle 170 GMT 18/ 6/2024 2:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 30 15.00 449 202 0.20 / 713.49 2 3
2 7 2010.40 53 14.89 3161 2495 2.70 / 715.98 2 2
3 13 1041.16 21 14.85 1812 565 3.26 / 716.54 2 7
4 13 297.68 21 15.02 737 232 3.49 / 716.78 2 4
5 8 0.04 175 15.06 259 683 4.18 / 717.46 2 3
Average= 4.20
(KJ/cycle)

Cycle 169 GMT 8/ 6/2024 7:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 15.01 433 195 0.19 / 709.13 2 3
2 7 2004.52 53 14.87 3157 2488 2.68 / 711.62 2 2
3 13 1030.52 21 14.84 1800 561 3.24 / 712.18 2 11
4 13 291.64 21 15.03 731 231 3.47 / 712.41 2 4
5 13 25.36 21 15.10 299 95 3.57 / 712.51 2 3
6 8 -0.04 175 15.06 258 680 4.25 / 713.19 2 4
7 14 -0.04 25 15.04 259 97 4.35 / 713.28 2 3
Average= 4.20
(KJ/cycle)

Cycle 168 GMT 29/ 5/2024 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 30 15.02 457 206 0.21 / 704.95 2 3
2 7 2003.56 53 14.89 3169 2501 2.71 / 707.45 2 2
3 13 1032.88 21 14.84 1808 563 3.27 / 708.02 2 6
4 13 284.76 21 15.03 725 229 3.50 / 708.25 2 4
5 8 -0.04 175 15.07 262 691 4.19 / 708.94 2 3
Average= 4.19
(KJ/cycle)

Cycle 167 GMT 19/ 5/2024 17:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 30 15.00 449 202 0.20 / 700.82 2 3
2 7 2003.40 52 14.88 3160 2445 2.65 / 703.26 2 2
3 13 1032.48 21 14.83 1803 562 3.21 / 703.83 2 7
4 13 273.40 21 15.04 702 222 3.43 / 704.05 2 4
5 8 0.12 175 15.07 265 699 4.13 / 704.75 2 3
Average= 4.19
(KJ/cycle)

Cycle 166 GMT 9/ 5/2024 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 30 15.01 431 194 0.19 / 696.62 2 3
2 7 2005.52 53 14.87 3168 2497 2.69 / 699.12 2 2
3 13 1045.44 21 14.83 1828 569 3.26 / 699.69 2 3
4 13 301.96 21 15.03 746 235 3.50 / 699.93 2 4
5 8 -0.04 175 15.07 262 691 4.19 / 700.62 2 3
Average= 4.20
(KJ/cycle)

Cycle 165 GMT 30/ 4/2024 3:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 30 15.00 457 206 0.21 / 692.46 2 3
2 7 2003.48 53 14.88 3155 2488 2.69 / 694.95 2 2
3 13 1030.40 21 14.85 1802 562 3.26 / 695.51 2 7
4 13 272.76 21 15.03 710 224 3.48 / 695.73 2 5
5 8 -0.08 175 15.07 264 696 4.18 / 696.43 2 3
Average= 4.20
(KJ/cycle)

Cycle 164 GMT 20/ 4/2024 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 30 15.01 428 193 0.19 / 688.28 2 3
2 7 2003.40 53 14.88 3151 2485 2.68 / 690.77 2 2
3 13 1028.84 21 14.84 1798 560 3.24 / 691.33 2 6
4 13 284.56 21 15.03 723 228 3.47 / 691.56 2 3
5 8 0.36 175 15.06 264 696 4.16 / 692.25 2 3
Average= 4.20
(KJ/cycle)

Cycle 163 GMT 10/ 4/2024 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 30 15.00 453 204 0.20 / 684.02 2 3
2 7 2012.32 53 14.89 3170 2502 2.71 / 686.52 2 2
3 13 1042.76 21 14.84 1818 567 3.27 / 687.09 2 6
4 13 296.48 21 15.03 735 232 3.50 / 687.32 2 4
5 8 -0.04 175 15.08 256 676 4.18 / 688.00 2 4
6 14 -0.04 25 15.05 257 97 4.28 / 688.09 2 5
Average= 4.20
(KJ/cycle)

Cycle 162 GMT 31/ 3/2024 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 15.01 434 195 0.20 / 679.85 2 3
2 7 2003.44 53 14.88 3162 2494 2.69 / 682.35 2 2
3 13 1027.40 21 14.85 1797 560 3.25 / 682.91 2 4
4 13 279.24 21 15.03 709 224 3.47 / 683.13 2 4
5 8 0.32 175 15.07 259 683 4.16 / 683.82 2 3
Average= 4.20
(KJ/cycle)

Cycle 161 GMT 22/ 3/2024 0: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 30 15.01 461 208 0.21 / 675.74 2 3
2 7 2006.08 52 14.87 3157 2441 2.65 / 678.18 2 2
3 13 1033.52 21 14.84 1810 564 3.21 / 678.75 2 8
4 13 285.56 21 15.04 715 226 3.44 / 678.97 2 4
5 8 0.08 175 15.07 260 686 4.12 / 679.66 2 3
Average= 4.20
(KJ/cycle)

Cycle 160 GMT 12/ 3/2024 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 30 15.00 454 204 0.20 / 671.57 2 3
2 7 2009.72 53 14.87 3171 2499 2.70 / 674.07 2 3
3 13 1025.24 21 14.84 1798 560 3.26 / 674.63 2 6
4 13 271.48 21 15.04 701 221 3.49 / 674.85 2 4
5 8 -0.04 175 15.07 261 688 4.17 / 675.54 2 3
Average= 4.20
(KJ/cycle)

Cycle 159 GMT 2/ 3/2024 10:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 15.01 427 192 0.19 / 667.33 2 3
2 7 2005.24 53 14.89 3165 2498 2.69 / 669.82 2 2
3 13 1030.00 21 14.85 1794 559 3.25 / 670.38 2 6
4 13 424.00 21 14.99 925 291 3.54 / 670.67 2 6
5 8 0.24 175 15.07 261 688 4.23 / 671.36 2 3
Average= 4.20
(KJ/cycle)

Cycle 158 GMT 21/ 2/2024 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 30 15.02 464 209 0.21 / 663.07 2 3
2 7 2004.88 53 14.88 3156 2489 2.70 / 665.56 2 2
3 13 1016.76 21 14.86 1778 555 3.25 / 666.12 2 7
4 13 282.72 21 15.04 715 226 3.48 / 666.34 2 4
5 8 0.08 175 15.08 262 691 4.17 / 667.04 2 2
6 14 0.08 25 15.05 260 98 4.27 / 667.13 2 3
Average= 4.20
(KJ/cycle)

Cycle 157 GMT 11/ 2/2024 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 30 15.02 427 192 0.19 / 658.87 2 3
2 7 2005.04 53 14.89 3172 2503 2.70 / 661.37 2 3
3 13 1030.32 21 14.86 1804 563 3.26 / 661.94 2 4
4 13 295.20 21 15.04 741 234 3.49 / 662.17 2 3
5 8 0.12 175 15.08 263 694 4.19 / 662.86 2 2
Average= 4.20
(KJ/cycle)

Cycle 156 GMT 2/ 2/2024 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.88 30 15.01 466 210 0.21 / 654.70 2 3
2 7 2003.48 53 14.89 3171 2502 2.71 / 657.20 2 2
3 13 1027.16 21 14.85 1802 562 3.27 / 657.77 2 7
4 13 279.92 21 15.05 715 226 3.50 / 657.99 2 4
5 8 0.00 175 15.08 260 686 4.19 / 658.68 2 3
Average= 4.20
(KJ/cycle)

Cycle 155 GMT 23/ 1/2024 4:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 30 15.00 460 207 0.21 / 650.52 2 3
2 7 2004.44 53 14.90 3164 2499 2.71 / 653.02 2 3
3 13 1024.64 21 14.86 1795 560 3.27 / 653.58 2 7
4 13 272.88 21 15.06 706 223 3.49 / 653.80 2 4
5 8 -0.04 175 15.09 262 692 4.18 / 654.49 2 3
Average= 4.20
(KJ/cycle)

Cycle 154 GMT 13/ 1/2024 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 30 15.02 450 203 0.20 / 646.28 2 3
2 7 2010.60 52 14.88 3167 2450 2.65 / 648.73 2 2
3 13 1040.60 21 14.85 1817 567 3.22 / 649.30 2 5
4 13 288.40 21 15.04 730 231 3.45 / 649.53 2 4
5 13 19.80 21 15.11 295 94 3.54 / 649.62 2 3
6 8 0.12 175 15.07 261 688 4.23 / 650.31 2 3
Average= 4.20
(KJ/cycle)

Cycle 153 GMT 3/ 1/2024 9:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 30 15.01 453 204 0.20 / 642.11 2 3
2 7 2006.04 53 14.88 3150 2484 2.69 / 644.59 2 3
3 13 1043.16 21 14.85 1820 568 3.26 / 645.16 2 7
4 13 291.76 21 15.04 729 230 3.49 / 645.39 2 4
5 8 0.16 175 15.08 260 686 4.17 / 646.08 2 3
Average= 4.20
(KJ/cycle)

Cycle 152 GMT 24/12/2023 11:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 30 15.02 461 208 0.21 / 637.92 2 3
2 7 2008.84 53 14.88 3167 2498 2.71 / 640.41 2 2
3 13 1035.72 21 14.86 1802 562 3.27 / 640.98 2 8
4 13 287.64 21 15.05 731 231 3.50 / 641.21 2 4
5 8 0.00 175 15.09 265 700 4.20 / 641.91 2 2
Average= 4.20
(KJ/cycle)

Cycle 151 GMT 14/12/2023 14:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 30 15.02 467 210 0.21 / 633.71 2 3
2 7 2008.08 53 14.89 3165 2498 2.71 / 636.21 2 2
3 13 1032.52 21 14.86 1807 564 3.27 / 636.78 2 11
4 13 298.80 21 15.04 745 235 3.51 / 637.01 2 4
5 8 0.00 175 15.09 264 697 4.20 / 637.71 2 3
Average= 4.20
(KJ/cycle)

Cycle 150 GMT 4/12/2023 16:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 30 15.02 448 202 0.20 / 629.53 2 3
2 7 2009.00 53 14.88 3163 2494 2.70 / 632.02 2 2
3 13 1033.08 21 14.87 1805 564 3.26 / 632.58 2 4
4 13 279.12 21 15.04 713 225 3.49 / 632.81 2 4
5 8 -0.04 175 15.09 263 695 4.18 / 633.50 2 2
Average= 4.20
(KJ/cycle)

Cycle 149 GMT 24/11/2023 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 30 15.02 454 205 0.20 / 625.42 2 3
2 7 2003.24 52 14.89 3153 2441 2.65 / 627.86 2 2
3 13 1021.44 21 14.87 1781 556 3.20 / 628.42 2 4
4 13 270.92 21 15.05 693 219 3.42 / 628.64 2 5
5 8 0.32 175 15.09 260 687 4.11 / 629.32 2 3
Average= 4.20
(KJ/cycle)

Cycle 148 GMT 14/11/2023 22: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 15.02 461 208 0.21 / 621.25 2 3
2 7 2005.96 53 14.89 3151 2487 2.69 / 623.74 2 2
3 13 1039.76 21 14.86 1814 566 3.26 / 624.30 2 3
4 13 293.76 21 15.05 730 231 3.49 / 624.53 2 4
5 8 -0.04 175 15.09 258 681 4.17 / 625.22 2 2
Average= 4.20
(KJ/cycle)

Cycle 147 GMT 5/11/2023 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 30 15.02 452 204 0.20 / 617.06 2 3
2 7 2004.12 53 14.89 3162 2495 2.70 / 619.56 2 2
3 13 1034.16 21 14.85 1800 561 3.26 / 620.12 2 6
4 13 300.64 21 15.04 743 235 3.50 / 620.35 2 4
5 8 0.12 175 15.09 261 689 4.18 / 621.04 2 3
Average= 4.20
(KJ/cycle)

Cycle 146 GMT 26/10/2023 3:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 30 15.04 461 208 0.21 / 612.89 2 3
2 7 2010.60 53 14.89 3174 2505 2.71 / 615.40 2 2
3 13 1014.44 21 14.86 1774 554 3.27 / 615.95 2 7
4 13 281.56 21 15.05 712 225 3.49 / 616.18 2 5
5 8 0.04 175 15.09 259 684 4.18 / 616.86 2 3
Average= 4.20
(KJ/cycle)

Cycle 145 GMT 16/10/2023 5:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 30 15.03 453 204 0.20 / 608.73 2 3
2 7 2004.24 52 14.91 3165 2454 2.66 / 611.19 2 2
3 13 1028.08 21 14.87 1803 563 3.22 / 611.75 2 7
4 13 280.72 21 15.06 719 227 3.45 / 611.98 2 5
5 8 0.08 175 15.10 267 706 4.15 / 612.68 2 3
Average= 4.20
(KJ/cycle)

Cycle 144 GMT 6/10/2023 8:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 30 15.03 470 212 0.21 / 604.31 2 3
2 7 2003.64 53 14.90 3178 2510 2.72 / 606.82 2 2
3 13 1021.60 21 14.88 1796 561 3.28 / 607.38 2 7
4 13 277.52 21 15.07 717 227 3.51 / 607.61 2 5
5 13 19.00 21 15.13 303 96 3.61 / 607.71 2 2
6 8 0.08 175 15.09 273 721 4.33 / 608.43 2 3
7 14 0.08 25 15.07 274 103 4.43 / 608.53 2 3
Average= 4.20
(KJ/cycle)

Cycle 143 GMT 26/ 9/2023 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 30 15.03 455 205 0.21 / 600.09 2 3
2 7 2003.28 53 14.91 3164 2500 2.71 / 602.59 2 3
3 13 1031.48 21 14.87 1810 565 3.27 / 603.15 2 4
4 13 282.48 21 15.06 726 230 3.50 / 603.38 2 4
5 8 -0.24 175 15.10 272 719 4.22 / 604.10 2 3
Average= 4.20
(KJ/cycle)

Cycle 142 GMT 16/ 9/2023 13:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 30 15.06 446 202 0.20 / 595.90 2 3
2 7 2003.20 53 14.89 3158 2492 2.69 / 598.39 2 3
3 13 1029.00 21 14.87 1803 563 3.26 / 598.96 2 7
4 13 287.88 21 15.06 729 231 3.49 / 599.19 2 5
5 8 0.44 175 15.10 263 695 4.18 / 599.88 2 3
Average= 4.19
(KJ/cycle)

Cycle 141 GMT 6/ 9/2023 16:10:12

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 30 15.04 430 194 0.19 / 591.61 2 3
2 7 2007.24 53 14.90 3161 2496 2.69 / 594.11 2 3
3 13 1029.44 21 14.87 1805 564 3.25 / 594.67 2 6
4 13 287.24 21 15.06 734 232 3.49 / 594.90 2 4
5 8 -0.08 175 15.10 264 698 4.18 / 595.60 2 3
6 14 -0.08 25 15.08 264 100 4.28 / 595.70 2 3
Average= 4.20
(KJ/cycle)

Cycle 140 GMT 27/ 8/2023 18:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 30 15.03 433 195 0.20 / 587.35 2 3
2 7 2010.00 53 14.90 3161 2496 2.69 / 589.84 2 3
3 13 1025.16 21 14.87 1795 561 3.25 / 590.40 2 5
4 13 280.40 21 15.06 712 225 3.48 / 590.63 2 4
5 13 33.60 21 15.12 316 100 3.58 / 590.73 2 3
6 8 0.00 175 15.09 260 687 4.26 / 591.42 2 2
Average= 4.19
(KJ/cycle)

Cycle 139 GMT 17/ 8/2023 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 30 15.03 458 207 0.21 / 583.10 2 3
2 7 2004.80 53 14.89 3153 2488 2.69 / 585.59 2 2
3 13 1021.60 21 14.87 1786 558 3.25 / 586.15 2 6
4 13 253.44 21 15.06 678 214 3.47 / 586.36 2 5
5 8 0.32 175 15.09 262 692 4.16 / 587.05 2 3
6 14 0.32 25 15.07 263 99 4.26 / 587.15 2 3
Average= 4.19
(KJ/cycle)

Cycle 138 GMT 7/ 8/2023 23:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 30 15.04 449 203 0.20 / 578.92 2 3
2 7 2003.12 53 14.90 3150 2488 2.69 / 581.41 2 3
3 13 1026.96 21 14.86 1791 559 3.25 / 581.97 2 7
4 13 279.48 21 15.06 718 227 3.48 / 582.20 2 4
5 8 -0.20 175 15.10 263 695 4.17 / 582.89 2 2
Average= 4.19
(KJ/cycle)

Cycle 137 GMT 29/ 7/2023 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 30 15.03 464 209 0.21 / 574.63 2 3
2 7 2009.12 53 14.90 3160 2495 2.70 / 577.13 2 3
3 13 1039.04 21 14.87 1814 566 3.27 / 577.69 2 5
4 13 290.72 21 15.06 733 232 3.50 / 577.93 2 3
5 8 0.24 175 15.10 264 698 4.20 / 578.62 2 3
6 14 0.24 25 15.08 262 99 4.30 / 578.72 2 3
Average= 4.19
(KJ/cycle)

Cycle 136 GMT 19/ 7/2023 4:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 15.05 458 207 0.21 / 570.47 2 3
2 7 2004.08 52 14.92 3167 2457 2.66 / 572.93 2 3
3 13 1046.64 21 14.88 1821 569 3.23 / 573.49 2 7
4 13 302.88 21 15.06 745 236 3.47 / 573.73 2 4
5 8 -0.08 175 15.11 262 693 4.16 / 574.42 2 3
Average= 4.19
(KJ/cycle)

Cycle 135 GMT 9/ 7/2023 7:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 30 15.04 432 195 0.19 / 566.28 2 3
2 7 2011.12 53 14.89 3171 2502 2.70 / 568.78 2 2
3 13 1025.92 21 14.88 1787 558 3.26 / 569.34 2 9
4 13 276.04 21 15.06 712 225 3.48 / 569.56 2 5
5 8 0.00 175 15.10 264 698 4.18 / 570.26 2 3
Average= 4.19
(KJ/cycle)

Cycle 134 GMT 29/ 6/2023 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 30 15.04 449 203 0.20 / 562.01 2 3
2 7 2011.40 53 14.89 3160 2494 2.70 / 564.50 2 4
3 13 1032.32 21 14.88 1808 565 3.26 / 565.07 2 8
4 13 278.40 21 15.06 712 225 3.49 / 565.29 2 4
5 8 0.44 175 15.10 262 692 4.18 / 565.98 2 3
6 14 0.44 25 15.07 262 99 4.28 / 566.08 2 5
Average= 4.19
(KJ/cycle)

Cycle 133 GMT 19/ 6/2023 12:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 30 15.05 459 207 0.21 / 557.73 3 3
2 7 2005.56 53 14.90 3162 2497 2.70 / 560.23 2 3
3 13 1023.68 21 14.87 1791 559 3.26 / 560.79 2 8
4 13 266.92 21 15.06 695 220 3.48 / 561.01 2 3
5 8 -0.20 175 15.10 264 698 4.18 / 561.71 2 2
6 14 -0.20 25 15.08 264 100 4.28 / 561.81 2 2
Average= 4.19
(KJ/cycle)

Cycle 132 GMT 9/ 6/2023 14:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 30 15.04 446 201 0.20 / 553.45 2 3
2 7 2006.08 53 14.91 3170 2505 2.71 / 555.95 2 3
3 13 1015.88 21 14.89 1789 559 3.27 / 556.51 2 8
4 13 268.20 21 15.09 701 222 3.49 / 556.73 2 3
5 8 -0.08 175 15.11 262 693 4.18 / 557.43 2 3
6 14 -0.08 25 15.09 262 99 4.28 / 557.52 2 3
Average= 4.19
(KJ/cycle)

Cycle 131 GMT 30/ 5/2023 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 30 15.03 431 194 0.19 / 549.15 2 3
2 7 2005.40 53 14.90 3157 2493 2.69 / 551.64 2 2
3 13 1034.56 21 14.87 1815 567 3.25 / 552.21 2 9
4 13 298.24 21 15.07 745 236 3.49 / 552.44 2 4
5 8 0.00 175 15.11 266 703 4.19 / 553.14 2 3
6 14 0.00 25 15.09 267 101 4.29 / 553.25 2 6
Average= 4.19
(KJ/cycle)

Cycle 130 GMT 20/ 5/2023 20: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 30 15.05 455 205 0.21 / 544.94 2 3
2 7 2010.68 53 14.91 3166 2502 2.71 / 547.44 2 3
3 13 1047.28 21 14.88 1830 572 3.28 / 548.01 2 7
4 13 301.52 21 15.07 751 238 3.52 / 548.25 2 4
5 8 0.20 175 15.10 266 703 4.22 / 548.95 2 3
Average= 4.19
(KJ/cycle)

Cycle 129 GMT 10/ 5/2023 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 30 15.04 458 207 0.21 / 540.64 2 3
2 7 2008.72 53 14.91 3171 2506 2.71 / 543.15 2 3
3 13 1041.92 21 14.88 1814 567 3.28 / 543.71 2 4
4 13 277.48 21 15.08 709 225 3.50 / 543.94 2 4
5 8 0.00 175 15.11 263 695 4.20 / 544.63 2 3
6 14 0.00 25 15.09 260 98 4.30 / 544.73 3 4
Average= 4.19
(KJ/cycle)

Cycle 128 GMT 1/ 5/2023 1: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 30 15.02 446 201 0.20 / 536.46 2 3
2 7 2004.04 53 14.91 3156 2494 2.69 / 538.95 2 3
3 13 1037.64 21 14.88 1810 566 3.26 / 539.52 2 7
4 13 271.00 21 15.08 702 222 3.48 / 539.74 2 4
5 8 0.16 175 15.10 263 695 4.18 / 540.43 2 4
Average= 4.19
(KJ/cycle)

Cycle 127 GMT 21/ 4/2023 3:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 30 15.03 448 202 0.20 / 532.29 2 3
2 7 2004.60 53 14.90 3151 2488 2.69 / 534.78 2 3
3 13 1034.40 21 14.87 1800 562 3.25 / 535.34 2 4
4 13 282.00 21 15.06 713 225 3.48 / 535.57 2 5
5 8 0.04 175 15.09 261 689 4.17 / 536.26 2 3
Average= 4.19
(KJ/cycle)

Cycle 126 GMT 11/ 4/2023 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 30 15.04 446 201 0.20 / 528.16 2 3
2 7 2007.00 52 14.90 3161 2449 2.65 / 530.61 2 2
3 13 1034.32 21 14.87 1804 563 3.21 / 531.17 2 4
4 13 284.84 21 15.06 720 228 3.44 / 531.40 2 4
5 8 0.00 175 15.10 262 692 4.13 / 532.09 2 3
Average= 4.19
(KJ/cycle)

Cycle 125 GMT 1/ 4/2023 8:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 30 15.03 457 206 0.21 / 523.99 2 3
2 7 2008.28 53 14.90 3158 2494 2.70 / 526.48 2 3
3 13 1029.64 21 14.89 1796 562 3.26 / 527.04 2 5
4 13 278.40 21 15.07 709 224 3.49 / 527.27 2 3
5 8 -0.08 175 15.10 260 687 4.17 / 527.96 2 4
Average= 4.19
(KJ/cycle)

Cycle 124 GMT 22/ 3/2023 11: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 30 15.03 439 198 0.20 / 519.79 2 3
2 7 2011.44 53 14.91 3160 2497 2.70 / 522.29 2 3
3 13 1048.32 21 14.88 1825 570 3.27 / 522.86 2 5
4 13 289.96 21 15.06 730 231 3.50 / 523.09 2 4
5 8 0.12 175 15.10 263 695 4.19 / 523.78 2 3
Average= 4.19
(KJ/cycle)

Cycle 123 GMT 12/ 3/2023 13:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 30 15.03 449 202 0.20 / 515.61 2 3
2 7 2009.80 53 14.90 3156 2492 2.69 / 518.10 2 2
3 13 1033.08 21 14.89 1797 562 3.26 / 518.66 2 8
4 13 286.20 21 15.06 729 231 3.49 / 518.89 2 4
5 8 0.20 175 15.10 264 698 4.18 / 519.59 2 4
Average= 4.19
(KJ/cycle)

Cycle 122 GMT 2/ 3/2023 16:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 30 15.03 455 205 0.21 / 511.42 2 3
2 7 2012.60 53 14.91 3170 2505 2.71 / 513.92 2 3
3 13 1040.92 21 14.88 1811 566 3.28 / 514.49 2 5
4 13 294.08 21 15.07 735 233 3.51 / 514.72 2 4
5 8 -0.08 175 15.10 260 687 4.20 / 515.41 2 6
Average= 4.19
(KJ/cycle)

Cycle 121 GMT 20/ 2/2023 18:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 30 15.04 459 207 0.21 / 507.13 3 3
2 7 2003.28 53 14.91 3163 2499 2.71 / 509.63 2 3
3 13 1159.00 21 14.85 1984 619 3.33 / 510.25 2 7
4 13 366.88 21 15.04 847 268 3.59 / 510.52 2 4
5 8 -0.12 175 15.10 262 692 4.29 / 511.21 2 3
Average= 4.19
(KJ/cycle)

Cycle 120 GMT 10/ 2/2023 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 30 15.03 449 202 0.20 / 502.94 2 3
2 7 2002.92 53 14.91 3171 2506 2.71 / 505.44 2 3
3 13 1030.96 21 14.88 1803 563 3.27 / 506.00 2 8
4 13 281.24 21 15.07 715 226 3.50 / 506.23 2 4
5 8 0.20 175 15.10 263 695 4.19 / 506.93 2 3
Average= 4.19
(KJ/cycle)

Cycle 119 GMT 1/ 2/2023 0: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 30 15.04 456 206 0.21 / 498.56 2 4
2 7 2009.48 52 14.90 3170 2456 2.66 / 501.02 2 4
3 13 1022.60 21 14.89 1791 560 3.22 / 501.58 2 7
4 13 279.52 21 15.06 721 228 3.45 / 501.81 2 4
5 13 98.52 21 15.11 438 139 3.59 / 501.94 2 4
6 8 -0.04 175 15.10 261 690 4.28 / 502.63 2 3
7 14 -0.04 25 15.07 262 99 4.38 / 502.73 2 4
Average= 4.19
(KJ/cycle)

Cycle 118 GMT 22/ 1/2023 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 30 15.04 456 206 0.21 / 494.42 2 3
2 7 2003.60 52 14.92 3153 2446 2.65 / 496.86 2 2
3 13 1029.08 21 14.90 1808 566 3.22 / 497.43 2 7
4 13 274.52 21 15.08 711 225 3.44 / 497.66 2 4
5 8 -0.12 175 15.10 265 700 4.14 / 498.36 2 4
Average= 4.19
(KJ/cycle)

Cycle 117 GMT 12/ 1/2023 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 30 15.04 454 205 0.20 / 490.25 2 3
2 7 2009.68 52 14.92 3174 2463 2.67 / 492.71 2 3
3 13 1030.88 21 14.88 1807 565 3.23 / 493.28 2 6
4 13 290.44 21 15.07 744 235 3.47 / 493.51 2 4
5 8 0.20 175 15.11 265 701 4.17 / 494.21 2 3
Average= 4.19
(KJ/cycle)

Cycle 116 GMT 2/ 1/2023 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 15.03 432 195 0.19 / 486.02 2 3
2 7 2002.88 52 14.91 3149 2441 2.64 / 488.46 2 3
3 13 1030.04 21 14.89 1799 563 3.20 / 489.02 2 9
4 13 280.12 21 15.08 718 227 3.43 / 489.25 2 5
5 8 0.04 175 15.11 262 693 4.12 / 489.94 2 3
6 14 0.04 25 15.08 263 99 4.22 / 490.04 2 4
Average= 4.19
(KJ/cycle)

Cycle 115 GMT 23/12/2022 9:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 30 15.04 436 197 0.20 / 481.84 2 3
2 7 2005.44 53 14.91 3163 2499 2.70 / 484.34 2 3
3 13 1019.20 21 14.89 1787 559 3.25 / 484.90 2 5
4 13 263.52 21 15.08 698 221 3.48 / 485.12 2 4
5 8 0.20 175 15.10 268 708 4.18 / 485.83 2 5
Average= 4.19
(KJ/cycle)

Cycle 114 GMT 13/12/2022 12:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 30 15.05 464 209 0.21 / 477.64 2 3
2 7 2009.44 53 14.91 3159 2496 2.71 / 480.14 2 3
3 13 1042.48 21 14.90 1817 569 3.27 / 480.70 2 6
4 13 305.84 21 15.06 757 239 3.51 / 480.94 2 4
5 8 0.08 175 15.11 264 698 4.21 / 481.64 2 3
Average= 4.19
(KJ/cycle)

Cycle 113 GMT 3/12/2022 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.40 30 15.04 476 215 0.21 / 473.46 2 3
2 7 2008.12 53 14.90 3154 2491 2.71 / 475.95 2 3
3 13 1015.36 21 14.90 1782 558 3.26 / 476.51 2 4
4 13 258.04 21 15.08 686 217 3.48 / 476.72 2 4
5 8 0.00 175 15.11 267 706 4.19 / 477.43 2 3
Average= 4.19
(KJ/cycle)

Cycle 112 GMT 23/11/2022 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 30 15.05 460 208 0.21 / 469.25 2 3
2 7 2004.40 53 14.91 3151 2490 2.70 / 471.74 2 5
3 13 1041.52 21 14.89 1820 569 3.27 / 472.31 2 10
4 13 286.40 21 15.08 724 229 3.50 / 472.53 2 4
5 8 0.12 175 15.11 268 709 4.20 / 473.24 2 3
Average= 4.19
(KJ/cycle)

Cycle 111 GMT 13/11/2022 20: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 30 15.06 462 209 0.21 / 465.09 2 3
2 7 2008.04 52 14.92 3167 2457 2.67 / 467.55 2 3
3 13 1039.16 21 14.89 1808 565 3.23 / 468.11 2 9
4 13 279.80 21 15.07 715 226 3.46 / 468.34 2 4
5 8 0.04 175 15.12 265 701 4.16 / 469.04 2 3
Average= 4.19
(KJ/cycle)

Cycle 110 GMT 3/11/2022 22:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 30 15.05 467 211 0.21 / 460.90 3 3
2 7 2003.16 53 14.92 3153 2493 2.70 / 463.40 2 3
3 13 1009.56 21 14.89 1769 553 3.26 / 463.95 2 8
4 13 271.52 21 15.08 709 225 3.48 / 464.17 2 4
5 8 0.12 175 15.12 267 706 4.19 / 464.88 2 3
Average= 4.19
(KJ/cycle)

Cycle 109 GMT 25/10/2022 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 30 15.06 457 206 0.21 / 456.67 2 3
2 7 2007.28 53 14.92 3172 2508 2.71 / 459.18 2 5
3 13 1028.00 21 14.90 1809 566 3.28 / 459.74 2 4
4 13 292.88 21 15.07 743 235 3.52 / 459.98 2 3
5 8 0.08 175 15.12 270 714 4.23 / 460.69 2 3
Average= 4.19
(KJ/cycle)

Cycle 108 GMT 15/10/2022 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 30 15.06 462 209 0.21 / 452.36 2 3
2 7 2005.64 53 14.92 3164 2502 2.71 / 454.86 2 3
3 13 1024.32 21 14.91 1792 561 3.27 / 455.42 2 7
4 13 273.52 21 15.09 711 225 3.50 / 455.65 2 4
5 8 -0.12 175 15.13 270 715 4.21 / 456.36 2 3
6 14 -0.12 25 15.11 269 102 4.31 / 456.46 2 3
Average= 4.19
(KJ/cycle)

Cycle 107 GMT 5/10/2022 6: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 30 15.07 454 205 0.21 / 448.15 2 3
2 7 2008.52 53 14.93 3166 2505 2.71 / 450.65 2 4
3 13 1022.04 21 14.90 1789 560 3.27 / 451.21 2 6
4 13 269.56 21 15.09 703 223 3.49 / 451.44 2 4
5 8 0.04 175 15.12 269 712 4.20 / 452.15 2 3
Average= 4.19
(KJ/cycle)

Cycle 106 GMT 25/ 9/2022 8:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 30 15.06 463 209 0.21 / 443.96 2 3
2 7 2002.60 53 14.93 3146 2489 2.70 / 446.45 2 5
3 13 1017.12 21 14.91 1784 559 3.26 / 447.01 2 6
4 13 275.60 21 15.10 717 227 3.48 / 447.23 2 4
5 8 -0.08 175 15.14 268 710 4.19 / 447.94 2 3
Average= 4.19
(KJ/cycle)

Cycle 105 GMT 15/ 9/2022 11:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 15.07 439 198 0.20 / 439.74 2 3
2 7 2011.08 53 14.92 3162 2500 2.70 / 442.24 2 4
3 13 1032.28 21 14.90 1797 562 3.26 / 442.80 2 7
4 13 287.84 21 15.09 724 229 3.49 / 443.03 2 4
5 8 0.12 175 15.13 271 718 4.21 / 443.75 2 3
Average= 4.19
(KJ/cycle)

Cycle 104 GMT 5/ 9/2022 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 30 15.06 459 207 0.21 / 435.55 2 3
2 7 2002.84 53 14.94 3162 2504 2.71 / 438.06 2 3
3 13 1024.12 21 14.92 1793 562 3.27 / 438.62 2 5
4 13 269.12 21 15.09 698 221 3.49 / 438.84 2 4
5 8 0.08 175 15.14 265 702 4.20 / 439.54 2 2
Average= 4.19
(KJ/cycle)

Cycle 103 GMT 26/ 8/2022 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 30 15.07 463 209 0.21 / 431.29 2 3
2 7 2004.00 52 14.94 3169 2462 2.67 / 433.75 2 4
3 13 1033.44 21 14.91 1805 565 3.24 / 434.32 2 5
4 13 276.76 21 15.11 713 226 3.46 / 434.54 2 3
5 8 0.04 175 15.13 265 702 4.16 / 435.24 2 3
6 14 0.04 25 15.12 266 101 4.26 / 435.34 2 2
Average= 4.19
(KJ/cycle)

Cycle 102 GMT 16/ 8/2022 19: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 15.07 440 199 0.20 / 427.07 2 3
2 7 2003.28 53 14.95 3154 2499 2.70 / 429.57 2 3
3 13 1028.12 21 14.93 1796 563 3.26 / 430.14 2 4
4 13 285.36 21 15.12 727 231 3.49 / 430.37 2 5
5 8 -0.08 175 15.13 269 712 4.20 / 431.08 2 3
Average= 4.19
(KJ/cycle)

Cycle 101 GMT 6/ 8/2022 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 30 15.08 453 205 0.20 / 422.87 2 3
2 7 2004.12 53 14.95 3155 2500 2.70 / 425.37 2 4
3 13 1035.88 21 14.93 1812 568 3.27 / 425.94 2 5
4 13 289.92 21 15.10 736 233 3.51 / 426.17 2 3
5 8 0.00 175 15.13 266 704 4.21 / 426.88 2 3
Average= 4.19
(KJ/cycle)

Cycle 100 GMT 28/ 7/2022 0:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 30 15.08 463 209 0.21 / 418.57 2 3
2 7 2002.84 53 14.93 3160 2500 2.71 / 421.07 2 4
3 13 1148.28 21 14.89 1967 615 3.32 / 421.68 2 4
4 13 376.48 21 15.07 860 272 3.60 / 421.96 2 5
5 8 0.36 175 15.14 267 707 4.30 / 422.66 2 3
Average= 4.18
(KJ/cycle)

Cycle 99 GMT 18/ 7/2022 3: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 30 15.07 460 208 0.21 / 414.38 2 3
2 7 2005.84 53 14.94 3162 2504 2.71 / 416.88 2 3
3 13 1024.36 21 14.93 1787 560 3.27 / 417.44 2 10
4 13 261.60 21 15.13 689 219 3.49 / 417.66 2 4
5 8 0.12 175 15.14 263 697 4.19 / 418.36 2 3
Average= 4.18
(KJ/cycle)

Cycle 98 GMT 8/ 7/2022 5:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 30 15.07 438 198 0.20 / 410.07 2 3
2 7 2009.92 53 14.93 3175 2512 2.71 / 412.58 2 4
3 13 1030.84 21 14.93 1805 566 3.28 / 413.14 2 9
4 13 269.40 21 15.12 706 224 3.50 / 413.37 2 5
5 8 -0.08 175 15.14 265 702 4.20 / 414.07 2 5
6 14 -0.08 25 15.12 269 102 4.30 / 414.17 2 4
Average= 4.18
(KJ/cycle)

Cycle 97 GMT 28/ 6/2022 8:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 30 15.07 444 201 0.20 / 405.88 2 3
2 7 2003.68 53 14.93 3158 2499 2.70 / 408.38 2 4
3 13 1010.20 21 14.93 1781 558 3.26 / 408.93 2 5
4 13 268.76 21 15.11 703 223 3.48 / 409.16 2 3
5 8 0.28 175 15.14 268 710 4.19 / 409.87 2 4
Average= 4.18
(KJ/cycle)

Cycle 96 GMT 18/ 6/2022 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 29 15.07 478 209 0.21 / 401.58 2 3
2 7 2004.48 53 14.94 3162 2504 2.71 / 404.08 2 3
3 13 1022.76 21 14.92 1793 562 3.27 / 404.64 2 9
4 13 268.40 21 15.11 710 225 3.50 / 404.87 2 4
5 13 22.24 21 15.17 307 98 3.60 / 404.97 2 2
6 8 0.00 175 15.13 268 710 4.31 / 405.68 2 3
Average= 4.18
(KJ/cycle)

Cycle 95 GMT 8/ 6/2022 13:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 29 15.07 469 205 0.20 / 397.26 2 3
2 7 2008.36 52 14.94 3164 2458 2.66 / 399.72 2 3
3 13 1024.84 21 14.93 1802 565 3.23 / 400.28 2 11
4 13 294.64 21 15.11 752 239 3.47 / 400.52 2 4
5 8 -0.16 175 15.14 280 742 4.21 / 401.26 2 3
6 14 -0.16 25 15.12 278 105 4.31 / 401.37 2 3
Average= 4.18
(KJ/cycle)

Cycle 94 GMT 29/ 5/2022 15:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 29 15.08 431 188 0.19 / 393.02 2 3
2 7 2012.68 53 14.92 3165 2503 2.69 / 395.52 2 4
3 13 1041.16 21 14.91 1825 571 3.26 / 396.09 2 5
4 13 302.32 21 15.10 759 241 3.50 / 396.33 2 5
5 8 0.16 175 15.13 274 725 4.23 / 397.06 2 2
Average= 4.18
(KJ/cycle)

Cycle 93 GMT 19/ 5/2022 18: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 29 15.09 435 190 0.19 / 388.83 2 3
2 7 2009.28 53 14.95 3170 2512 2.70 / 391.34 2 4
3 13 1015.48 21 14.94 1776 557 3.26 / 391.90 2 7
4 13 263.04 21 15.13 695 221 3.48 / 392.12 2 3
5 8 -0.04 175 15.15 267 708 4.19 / 392.83 2 3
Average= 4.18
(KJ/cycle)

Cycle 92 GMT 9/ 5/2022 20:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 29 15.08 431 188 0.19 / 384.63 2 3
2 7 2010.08 53 14.94 3165 2506 2.69 / 387.14 2 5
3 13 1028.76 21 14.94 1794 563 3.26 / 387.70 2 6
4 13 276.04 21 15.11 716 227 3.48 / 387.93 2 4
5 8 0.12 175 15.15 269 713 4.20 / 388.64 2 4
Average= 4.18
(KJ/cycle)

Cycle 91 GMT 29/ 4/2022 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 29 15.07 438 191 0.19 / 380.49 2 3
2 7 2011.36 52 14.94 3170 2463 2.65 / 382.95 2 4
3 13 1020.44 21 14.93 1790 561 3.22 / 383.51 2 9
4 13 266.40 21 15.13 705 224 3.44 / 383.74 2 4
5 8 0.28 175 15.15 266 705 4.14 / 384.44 2 4
Average= 4.18
(KJ/cycle)

Cycle 90 GMT 20/ 4/2022 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 29 15.08 454 199 0.20 / 376.11 2 3
2 7 2011.76 53 14.94 3169 2509 2.71 / 378.62 2 5
3 13 1025.44 21 14.92 1798 563 3.27 / 379.18 2 5
4 13 404.44 21 15.08 901 285 3.56 / 379.47 2 4
5 13 36.96 21 15.17 335 107 3.66 / 379.57 2 3
6 8 -0.12 175 15.12 274 725 4.39 / 380.30 2 3
Average= 4.18
(KJ/cycle)

Cycle 89 GMT 10/ 4/2022 4: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 29 15.07 439 192 0.19 / 371.89 2 3
2 7 2008.72 53 14.96 3167 2511 2.70 / 374.40 2 3
3 13 1024.20 21 14.94 1799 564 3.27 / 374.97 2 10
4 13 294.52 21 15.12 741 235 3.50 / 375.20 2 5
5 8 0.16 175 15.15 266 705 4.21 / 375.91 2 3
Average= 4.18
(KJ/cycle)

Cycle 88 GMT 31/ 3/2022 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 29 15.08 428 187 0.19 / 367.54 2 3
2 7 2005.36 53 14.95 3149 2495 2.68 / 370.04 2 3
3 13 1029.32 21 14.93 1799 564 3.25 / 370.60 2 6
4 13 396.36 21 15.08 896 284 3.53 / 370.89 2 4
5 13 18.88 21 15.17 300 96 3.63 / 370.98 2 3
6 8 -0.20 175 15.13 271 718 4.34 / 371.70 2 3
Average= 4.18
(KJ/cycle)

Cycle 87 GMT 21/ 3/2022 9:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 15.08 426 186 0.19 / 363.27 3 3
2 7 2012.00 53 14.95 3167 2509 2.70 / 365.78 2 6
3 13 1022.48 21 14.95 1785 560 3.26 / 366.34 2 7
4 13 281.80 21 15.13 720 229 3.48 / 366.57 2 3
5 13 23.32 21 15.18 300 96 3.58 / 366.66 2 3
6 8 0.04 175 15.14 262 694 4.27 / 367.36 2 3
Average= 4.17
(KJ/cycle)

Cycle 86 GMT 11/ 3/2022 11:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 29 15.08 453 198 0.20 / 359.03 2 3
2 7 2007.16 53 14.95 3168 2510 2.71 / 361.54 2 3
3 13 911.96 21 14.97 1636 514 3.22 / 362.05 2 6
4 13 309.52 21 15.13 761 242 3.46 / 362.30 2 5
5 13 24.88 21 15.18 301 96 3.56 / 362.39 2 3
6 8 0.00 175 15.15 261 692 4.25 / 363.08 2 3
Average= 4.17
(KJ/cycle)

Cycle 85 GMT 1/ 3/2022 14:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 29 15.09 428 187 0.19 / 354.73 3 3
2 7 2009.72 53 14.95 3168 2510 2.70 / 357.24 2 4
3 13 1024.36 21 14.94 1800 565 3.26 / 357.81 2 8
4 13 266.72 21 15.14 701 223 3.49 / 358.03 2 5
5 13 22.52 21 15.18 303 97 3.58 / 358.13 2 3
6 8 0.16 175 15.14 266 705 4.29 / 358.83 2 6
Average= 4.17
(KJ/cycle)

Cycle 84 GMT 19/ 2/2022 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 29 15.08 450 197 0.20 / 350.46 2 3
2 7 2006.44 53 14.96 3165 2509 2.71 / 352.97 2 3
3 13 1005.60 21 14.96 1764 554 3.26 / 353.52 2 8
4 13 261.68 21 15.15 688 219 3.48 / 353.74 2 4
5 13 22.84 21 15.20 301 96 3.58 / 353.84 2 3
6 8 0.04 175 15.16 266 706 4.28 / 354.54 2 4
Average= 4.17
(KJ/cycle)

Cycle 83 GMT 9/ 2/2022 19:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 29 15.09 453 198 0.20 / 346.17 2 3
2 7 2007.64 53 14.94 3143 2489 2.69 / 348.65 2 3
3 13 1038.76 21 14.94 1814 569 3.26 / 349.22 2 6
4 13 283.68 21 15.12 727 231 3.49 / 349.45 2 5
5 13 23.76 21 15.18 307 98 3.58 / 349.55 2 3
6 8 -0.04 175 15.15 268 711 4.30 / 350.26 2 3
Average= 4.17
(KJ/cycle)

Cycle 82 GMT 30/ 1/2022 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 29 15.10 455 199 0.20 / 341.86 2 3
2 7 2007.12 53 14.96 3162 2507 2.71 / 344.37 2 3
3 13 1019.64 21 14.95 1786 561 3.27 / 344.93 2 4
4 13 274.12 21 15.14 715 227 3.49 / 345.16 2 4
5 13 20.32 21 15.21 304 97 3.59 / 345.25 2 3
6 8 0.04 175 15.16 269 714 4.31 / 345.97 2 5
Average= 4.17
(KJ/cycle)

Cycle 81 GMT 21/ 1/2022 0: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 15.10 454 206 0.21 / 337.47 2 3
2 7 2008.80 53 14.96 3168 2512 2.72 / 339.98 2 4
3 13 1012.20 21 14.96 1779 559 3.28 / 340.54 2 5
4 13 252.72 21 15.16 683 217 3.49 / 340.75 2 5
5 13 18.68 21 15.21 302 96 3.59 / 340.85 2 3
6 8 -0.28 175 15.17 268 711 4.30 / 341.56 2 5
7 14 -0.28 25 15.14 268 101 4.40 / 341.66 2 3
Average= 4.17
(KJ/cycle)

Cycle 80 GMT 11/ 1/2022 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 15.10 438 198 0.20 / 333.19 2 3
2 7 2003.80 52 14.97 3152 2454 2.65 / 335.64 2 6
3 13 1039.16 21 14.96 1818 571 3.22 / 336.22 2 8
4 13 283.76 21 15.15 727 231 3.45 / 336.45 2 5
5 13 22.96 21 15.20 310 99 3.55 / 336.55 2 3
6 8 0.08 175 15.16 269 714 4.27 / 337.26 2 4
Average= 4.16
(KJ/cycle)

Cycle 79 GMT 1/ 1/2022 5: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 30 15.10 466 211 0.21 / 329.00 2 3
2 7 2002.92 52 14.98 3165 2465 2.68 / 331.47 2 4
3 13 1023.40 21 14.97 1796 565 3.24 / 332.03 2 6
4 13 282.76 21 15.15 731 233 3.47 / 332.26 2 5
5 8 0.08 175 15.18 274 728 4.20 / 332.99 2 3
Average= 4.16
(KJ/cycle)

Cycle 78 GMT 22/12/2021 7:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 30 15.10 462 209 0.21 / 324.76 2 3
2 7 2006.64 53 14.97 3169 2514 2.72 / 327.28 2 3
3 13 1014.44 21 14.97 1786 561 3.29 / 327.84 2 7
4 13 259.28 21 15.16 696 222 3.51 / 328.06 2 4
5 8 -0.04 175 15.17 276 733 4.24 / 328.79 2 4
Average= 4.16
(KJ/cycle)

Cycle 77 GMT 12/12/2021 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 30 15.12 453 205 0.21 / 320.44 2 3
2 7 2008.20 53 14.97 3153 2502 2.71 / 322.95 2 4
3 13 1012.84 21 14.96 1783 560 3.27 / 323.51 2 8
4 13 272.00 21 15.16 712 227 3.49 / 323.73 2 4
5 8 0.20 175 15.17 270 717 4.21 / 324.45 2 3
6 14 0.20 25 15.15 269 102 4.31 / 324.55 2 5
Average= 4.16
(KJ/cycle)

Cycle 76 GMT 2/12/2021 12:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 29 15.12 461 202 0.20 / 316.25 2 3
2 7 2005.32 53 14.97 3155 2503 2.71 / 318.75 2 4
3 13 1021.20 21 14.96 1779 559 3.26 / 319.31 2 6
4 13 268.36 21 15.16 698 222 3.49 / 319.54 2 5
5 8 0.08 175 15.18 265 704 4.19 / 320.24 2 5
Average= 4.16
(KJ/cycle)

Cycle 75 GMT 22/11/2021 15:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 29 15.13 458 201 0.20 / 312.04 2 3
2 7 2005.24 53 14.97 3161 2508 2.71 / 314.55 2 5
3 13 1026.52 21 14.97 1793 564 3.27 / 315.11 2 10
4 13 268.48 21 15.17 703 224 3.50 / 315.34 2 3
5 8 0.08 175 15.19 267 710 4.21 / 316.05 2 5
Average= 4.16
(KJ/cycle)

Cycle 74 GMT 12/11/2021 17:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 29 15.13 461 202 0.20 / 307.89 3 3
2 7 2009.32 52 14.98 3166 2466 2.67 / 310.35 2 6
3 13 1013.12 21 14.97 1782 560 3.23 / 310.91 2 5
4 13 268.60 21 15.16 706 225 3.45 / 311.14 2 4
5 8 0.00 175 15.20 265 705 4.16 / 311.84 2 3
Average= 4.16
(KJ/cycle)

Cycle 73 GMT 2/11/2021 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 29 15.12 453 199 0.20 / 303.66 2 4
2 7 2008.40 53 14.98 3172 2518 2.72 / 306.18 2 3
3 13 1025.64 21 14.97 1797 565 3.28 / 306.74 2 9
4 13 279.28 21 15.16 721 230 3.51 / 306.97 2 3
5 8 0.04 175 15.19 267 710 4.22 / 307.68 2 3
Average= 4.16
(KJ/cycle)

Cycle 72 GMT 23/10/2021 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 29 15.13 460 202 0.20 / 299.50 2 3
2 7 2010.52 52 14.97 3166 2465 2.67 / 301.97 2 5
3 13 1022.80 21 14.97 1798 565 3.23 / 302.53 2 9
4 13 266.24 21 15.16 695 221 3.45 / 302.75 2 4
5 8 0.28 175 15.19 267 710 4.16 / 303.46 2 3
Average= 4.16
(KJ/cycle)

Cycle 71 GMT 14/10/2021 1:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 29 15.13 472 207 0.21 / 295.28 2 3
2 7 2012.24 53 14.98 3162 2510 2.72 / 297.79 2 3
3 13 1023.92 21 14.98 1801 567 3.28 / 298.36 2 6
4 13 268.12 21 15.18 700 223 3.51 / 298.58 2 4
5 8 0.00 175 15.20 271 721 4.23 / 299.30 2 3
Average= 4.16
(KJ/cycle)

Cycle 70 GMT 4/10/2021 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 29 15.14 473 208 0.21 / 291.11 2 3
2 7 2011.76 52 14.98 3165 2465 2.67 / 293.58 2 3
3 13 918.36 21 15.02 1649 520 3.19 / 294.10 2 4
4 13 316.72 21 15.15 776 247 3.44 / 294.34 2 3
5 8 0.08 175 15.21 274 729 4.17 / 295.07 2 3
Average= 4.16
(KJ/cycle)

Cycle 69 GMT 24/ 9/2021 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 29 15.15 465 204 0.20 / 286.89 2 3
2 7 2004.40 53 14.99 3160 2511 2.71 / 289.40 2 3
3 13 1004.32 21 14.98 1763 555 3.27 / 289.96 2 3
4 13 261.68 21 15.18 695 222 3.49 / 290.18 2 5
5 8 0.08 175 15.21 272 724 4.21 / 290.90 2 3
Average= 4.16
(KJ/cycle)

Cycle 68 GMT 14/ 9/2021 9: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 29 15.15 466 205 0.20 / 282.69 2 3
2 7 2003.32 53 14.99 3157 2508 2.71 / 285.19 2 5
3 13 1004.20 21 14.99 1767 556 3.27 / 285.75 2 5
4 13 261.24 21 15.19 695 222 3.49 / 285.97 2 3
5 8 0.16 175 15.22 269 716 4.21 / 286.69 2 3
Average= 4.15
(KJ/cycle)

Cycle 67 GMT 4/ 9/2021 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 29 15.16 474 208 0.21 / 278.56 2 3
2 7 2006.36 53 14.98 3160 2509 2.72 / 281.07 2 4
3 13 892.40 21 15.02 1609 508 3.22 / 281.58 2 5
4 13 179.88 21 15.21 566 181 3.41 / 281.76 2 3
5 8 -0.04 175 15.22 270 719 4.12 / 282.48 2 3
Average= 4.15
(KJ/cycle)

Cycle 66 GMT 25/ 8/2021 13:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 29 15.15 471 207 0.21 / 274.34 2 3
2 7 2009.76 53 14.98 3158 2507 2.71 / 276.85 2 7
3 13 1029.92 21 14.98 1807 568 3.28 / 277.42 2 11
4 13 257.40 21 15.18 686 219 3.50 / 277.64 2 3
5 8 0.00 175 15.22 269 716 4.22 / 278.36 2 2
Average= 4.15
(KJ/cycle)

Cycle 65 GMT 15/ 8/2021 16:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 29 15.16 441 194 0.19 / 270.03 2 3
2 7 2004.68 53 14.99 3148 2501 2.69 / 272.53 2 6
3 13 1011.36 21 15.00 1776 559 3.25 / 273.09 2 5
4 13 269.00 21 15.19 703 224 3.48 / 273.32 2 4
5 8 -0.08 175 15.22 270 719 4.20 / 274.04 2 2
6 14 -0.08 25 15.20 269 102 4.30 / 274.14 2 3
Average= 4.15
(KJ/cycle)

Cycle 64 GMT 5/ 8/2021 18:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 29 15.16 465 204 0.20 / 265.72 2 3
2 7 2009.48 53 14.98 3161 2510 2.71 / 268.23 2 4
3 13 998.80 21 15.00 1761 555 3.27 / 268.79 2 11
4 13 243.12 21 15.19 672 214 3.48 / 269.00 2 5
5 8 0.04 175 15.22 275 732 4.22 / 269.73 2 2
6 14 0.04 25 15.20 274 104 4.32 / 269.84 2 3
Average= 4.15
(KJ/cycle)

Cycle 63 GMT 26/ 7/2021 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 29 15.16 462 203 0.20 / 261.46 2 3
2 7 2006.28 53 15.00 3155 2508 2.71 / 263.97 2 7
3 13 1013.60 21 15.00 1782 561 3.27 / 264.53 2 7
4 13 156.00 21 15.21 538 172 3.44 / 264.70 2 3
5 8 0.08 175 15.23 268 714 4.16 / 265.42 2 3
6 14 0.08 25 15.21 270 103 4.26 / 265.52 2 7
Average= 4.15
(KJ/cycle)

Cycle 62 GMT 16/ 7/2021 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 29 15.17 443 195 0.19 / 257.17 2 3
2 7 2009.20 52 14.98 3180 2477 2.67 / 259.65 2 5
3 13 1004.96 21 14.99 1769 557 3.23 / 260.21 2 8
4 13 255.96 21 15.19 693 221 3.45 / 260.43 2 4
5 8 -0.24 175 15.22 272 724 4.17 / 261.15 2 2
6 14 -0.24 25 15.19 271 103 4.28 / 261.26 2 3
Average= 4.15
(KJ/cycle)

Cycle 61 GMT 7/ 7/2021 1:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 29 15.17 444 195 0.20 / 253.02 2 3
2 7 2003.48 52 15.00 3168 2471 2.67 / 255.49 2 5
3 13 1001.12 21 15.01 1767 557 3.22 / 256.05 2 3
4 13 244.88 21 15.20 668 213 3.44 / 256.26 2 4
5 8 0.04 175 15.22 270 719 4.16 / 256.98 2 3
Average= 4.14
(KJ/cycle)

Cycle 60 GMT 27/ 6/2021 4:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 15.17 468 206 0.21 / 248.81 2 3
2 7 2006.08 53 14.99 3159 2510 2.72 / 251.32 2 7
3 13 1015.56 21 15.01 1788 564 3.28 / 251.88 2 9
4 13 265.36 21 15.19 702 224 3.50 / 252.11 2 3
5 8 -0.04 175 15.23 269 717 4.22 / 252.82 2 3
Average= 4.14
(KJ/cycle)

Cycle 59 GMT 17/ 6/2021 6:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 29 15.17 476 209 0.21 / 244.58 2 3
2 7 2010.24 53 15.00 3161 2513 2.72 / 247.09 2 3
3 13 1009.12 21 15.00 1768 557 3.28 / 247.65 2 7
4 13 271.72 21 15.20 709 226 3.51 / 247.88 2 4
5 8 0.04 175 15.24 272 725 4.23 / 248.60 2 3
Average= 4.14
(KJ/cycle)

Cycle 58 GMT 7/ 6/2021 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 29 15.18 442 195 0.19 / 240.34 2 3
2 7 2010.04 53 15.00 3166 2517 2.71 / 242.86 2 7
3 13 1007.24 21 15.01 1773 559 3.27 / 243.42 2 4
4 13 264.96 21 15.21 701 224 3.49 / 243.64 2 4
5 8 0.40 175 15.23 275 733 4.23 / 244.37 2 3
Average= 4.14
(KJ/cycle)

Cycle 57 GMT 28/ 5/2021 11:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 29 15.17 464 204 0.20 / 236.17 2 3
2 7 2003.76 52 15.00 3164 2468 2.67 / 238.64 2 7
3 13 1000.36 21 15.02 1765 557 3.23 / 239.20 2 9
4 13 251.32 21 15.22 681 218 3.45 / 239.41 2 4
5 8 0.00 175 15.24 274 731 4.18 / 240.15 2 3
Average= 4.14
(KJ/cycle)

Cycle 56 GMT 18/ 5/2021 14: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 29 15.16 434 191 0.19 / 231.96 2 3
2 7 2010.72 53 14.99 3154 2506 2.70 / 234.47 2 7
3 13 1018.36 21 15.01 1782 562 3.26 / 235.03 2 7
4 13 253.28 21 15.22 680 217 3.48 / 235.25 2 3
5 8 -0.04 175 15.24 270 720 4.20 / 235.97 2 3
Average= 4.14
(KJ/cycle)

Cycle 55 GMT 8/ 5/2021 16:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 29 15.16 464 204 0.20 / 227.72 2 3
2 7 2004.24 52 15.00 3163 2467 2.67 / 230.18 2 4
3 13 1013.88 21 15.01 1782 562 3.23 / 230.75 2 8
4 13 249.40 21 15.21 675 216 3.45 / 230.96 2 4
5 8 -0.16 175 15.24 266 709 4.16 / 231.67 2 3
6 14 -0.16 25 15.21 265 101 4.26 / 231.77 2 3
Average= 4.14
(KJ/cycle)

Cycle 54 GMT 28/ 4/2021 19: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 29 15.16 460 202 0.20 / 223.50 2 3
2 7 2009.56 53 14.99 3154 2506 2.71 / 226.01 2 7
3 13 1024.92 21 15.01 1799 567 3.28 / 226.58 2 7
4 13 252.92 21 15.22 680 217 3.49 / 226.79 2 5
5 8 0.28 175 15.24 270 720 4.21 / 227.51 2 3
Average= 4.14
(KJ/cycle)

Cycle 53 GMT 18/ 4/2021 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 15.17 449 198 0.20 / 219.27 2 3
2 7 2009.36 53 15.00 3172 2522 2.72 / 221.80 2 5
3 13 1026.28 21 15.01 1795 566 3.29 / 222.36 2 6
4 13 252.28 21 15.23 685 219 3.50 / 222.58 2 4
5 8 -0.08 175 15.24 270 720 4.22 / 223.30 2 4
Average= 4.14
(KJ/cycle)

Cycle 52 GMT 9/ 4/2021 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 29 15.19 439 193 0.19 / 215.06 2 3
2 7 2004.80 53 15.01 3151 2507 2.70 / 217.57 2 5
3 13 1015.16 21 15.02 1784 563 3.26 / 218.13 2 6
4 13 249.52 21 15.23 679 217 3.48 / 218.35 2 4
5 8 0.08 175 15.24 273 728 4.21 / 219.08 2 3
Average= 4.13
(KJ/cycle)

Cycle 51 GMT 30/ 3/2021 2:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 29 15.19 454 200 0.20 / 210.88 2 3
2 7 2007.16 53 15.01 3157 2511 2.71 / 213.39 2 5
3 13 907.00 21 15.06 1630 516 3.23 / 213.91 2 4
4 13 314.40 21 15.21 776 248 3.47 / 214.16 2 3
5 8 -0.08 175 15.25 267 713 4.19 / 214.87 2 5
Average= 4.13
(KJ/cycle)

Cycle 50 GMT 20/ 3/2021 4:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 15.18 437 192 0.19 / 206.69 2 3
2 7 2009.48 53 15.02 3177 2529 2.72 / 209.22 2 6
3 13 1026.84 21 15.02 1799 567 3.29 / 209.79 2 4
4 13 162.28 21 15.27 547 175 3.46 / 209.96 2 5
5 8 0.08 175 15.25 269 718 4.18 / 210.68 2 3
Average= 4.13
(KJ/cycle)

Cycle 49 GMT 10/ 3/2021 7: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 29 15.20 464 205 0.20 / 202.38 2 3
2 7 2002.84 53 15.01 3159 2513 2.72 / 204.89 2 4
3 13 1020.28 21 15.03 1795 567 3.28 / 205.46 2 6
4 13 264.24 21 15.23 700 224 3.51 / 205.68 2 4
5 13 16.60 21 15.29 300 96 3.60 / 205.78 2 2
6 8 0.08 175 15.25 270 721 4.32 / 206.50 2 3
Average= 4.13
(KJ/cycle)

Cycle 48 GMT 28/ 2/2021 9:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 29 15.18 466 205 0.21 / 198.18 2 3
2 7 2005.84 53 15.01 3165 2518 2.72 / 200.70 2 6
3 13 1029.20 21 15.03 1816 573 3.30 / 201.27 2 5
4 13 148.32 21 15.27 531 170 3.47 / 201.44 2 4
5 8 0.16 175 15.26 274 732 4.20 / 202.17 2 4
Average= 4.13
(KJ/cycle)

Cycle 47 GMT 18/ 2/2021 11:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 29 15.20 467 206 0.21 / 193.82 2 3
2 7 2007.00 53 15.03 3166 2522 2.73 / 196.35 2 3
3 13 1031.56 21 15.03 1816 573 3.30 / 196.92 2 12
4 13 260.84 21 15.25 701 224 3.53 / 197.14 2 5
5 13 17.56 21 15.30 308 99 3.62 / 197.24 2 3
6 8 0.04 175 15.26 275 734 4.36 / 197.98 2 3
Average= 4.12
(KJ/cycle)

Cycle 46 GMT 8/ 2/2021 14:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 29 15.19 439 193 0.19 / 189.63 2 3
2 7 2009.12 53 15.02 3164 2519 2.71 / 192.15 2 4
3 13 1011.84 21 15.04 1781 563 3.27 / 192.71 2 5
4 13 154.40 21 15.27 539 173 3.45 / 192.89 2 4
5 8 -0.04 175 15.26 274 732 4.18 / 193.62 2 3
Average= 4.12
(KJ/cycle)

Cycle 45 GMT 29/ 1/2021 16:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 29 15.20 469 207 0.21 / 185.33 2 3
2 7 2009.92 53 15.01 3171 2523 2.73 / 187.85 2 4
3 13 1005.76 21 15.05 1769 559 3.29 / 188.41 2 6
4 13 238.92 21 15.25 659 211 3.50 / 188.62 2 4
5 13 15.68 21 15.31 299 96 3.60 / 188.72 2 3
6 8 0.00 175 15.26 269 718 4.31 / 189.44 2 3
Average= 4.12
(KJ/cycle)

Cycle 44 GMT 19/ 1/2021 19:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 29 15.21 469 207 0.21 / 181.19 2 3
2 7 2011.28 53 15.02 3171 2524 2.73 / 183.71 2 5
3 13 899.52 21 15.07 1619 512 3.24 / 184.22 2 5
4 13 176.72 21 15.27 568 182 3.43 / 184.40 2 3
5 8 -0.04 175 15.28 269 719 4.14 / 185.12 2 3
Average= 4.11
(KJ/cycle)

Cycle 43 GMT 9/ 1/2021 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 29 15.21 460 203 0.20 / 177.00 2 3
2 7 2010.80 53 15.02 3168 2522 2.72 / 179.52 2 6
3 13 1020.00 21 15.05 1795 567 3.29 / 180.09 2 8
4 13 146.72 21 15.29 527 169 3.46 / 180.26 2 3
5 8 0.12 175 15.28 270 722 4.18 / 180.98 2 2
Average= 4.11
(KJ/cycle)

Cycle 42 GMT 31/12/2020 0: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 29 15.22 467 206 0.21 / 172.89 2 3
2 7 2009.16 52 15.04 3164 2475 2.68 / 175.37 2 4
3 13 904.00 21 15.09 1632 517 3.20 / 175.88 2 6
4 13 180.52 21 15.28 577 185 3.38 / 176.07 2 4
5 8 0.12 175 15.28 272 727 4.11 / 176.80 2 2
Average= 4.11
(KJ/cycle)

Cycle 41 GMT 21/12/2020 2:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 29 15.21 469 207 0.21 / 168.74 2 3
2 7 2002.84 53 15.03 3136 2498 2.70 / 171.24 2 8
3 13 1012.44 21 15.05 1779 562 3.27 / 171.80 2 4
4 13 144.16 21 15.29 512 164 3.43 / 171.96 2 5
5 8 0.12 175 15.28 270 722 4.15 / 172.69 2 3
Average= 4.11
(KJ/cycle)

Cycle 40 GMT 11/12/2020 5: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 29 15.22 467 206 0.21 / 164.56 2 3
2 7 2006.80 52 15.04 3154 2467 2.67 / 167.03 2 4
3 13 1010.56 21 15.06 1777 562 3.23 / 167.59 2 8
4 13 243.36 21 15.26 669 214 3.45 / 167.80 2 4
5 8 0.04 175 15.28 272 727 4.18 / 168.53 2 3
Average= 4.11
(KJ/cycle)

Cycle 39 GMT 1/12/2020 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 29 15.23 468 207 0.21 / 160.24 2 3
2 7 2008.20 53 15.03 3154 2512 2.72 / 162.76 2 7
3 13 1017.20 21 15.05 1783 564 3.28 / 163.32 2 11
4 13 235.28 21 15.26 660 212 3.49 / 163.53 2 4
5 8 -0.08 175 15.28 270 722 4.22 / 164.25 2 3
6 14 -0.08 25 15.26 270 103 4.32 / 164.36 2 4
Average= 4.11
(KJ/cycle)

Cycle 38 GMT 21/11/2020 10: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 29 15.22 479 211 0.21 / 156.02 2 3
2 7 2003.36 53 15.04 3155 2515 2.73 / 158.53 2 5
3 13 1009.20 21 15.07 1775 562 3.29 / 159.10 2 4
4 13 229.72 21 15.27 655 210 3.50 / 159.31 2 3
5 8 0.12 175 15.29 273 730 4.23 / 160.04 2 2
Average= 4.10
(KJ/cycle)

Cycle 37 GMT 11/11/2020 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 29 15.22 466 206 0.21 / 151.82 2 3
2 7 2005.00 52 15.04 3176 2484 2.69 / 154.30 2 4
3 13 997.84 21 15.06 1765 558 3.25 / 154.86 2 6
4 13 236.80 21 15.26 662 212 3.46 / 155.07 2 4
5 8 0.24 175 15.29 275 736 4.20 / 155.81 2 2
Average= 4.10
(KJ/cycle)

Cycle 36 GMT 1/11/2020 14:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 29 15.22 469 207 0.21 / 147.56 2 3
2 7 2008.20 53 15.02 3176 2528 2.74 / 150.09 2 3
3 13 1004.96 21 15.07 1786 565 3.30 / 150.65 2 10
4 13 248.56 21 15.26 687 220 3.52 / 150.87 2 3
5 8 0.24 175 15.29 277 741 4.26 / 151.61 2 3
Average= 4.10
(KJ/cycle)

Cycle 35 GMT 22/10/2020 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 29 15.24 480 212 0.21 / 143.30 2 3
2 7 2006.16 53 15.04 3186 2540 2.75 / 145.84 2 3
3 13 1000.60 21 15.07 1776 562 3.31 / 146.40 2 3
4 13 221.60 21 15.28 644 207 3.52 / 146.61 2 3
5 8 -0.08 175 15.30 277 742 4.26 / 147.35 2 2
Average= 4.09
(KJ/cycle)

Cycle 34 GMT 12/10/2020 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 15.23 465 205 0.21 / 139.08 2 3
2 7 2007.72 53 15.05 3176 2533 2.74 / 141.61 2 2
3 13 1016.48 21 15.07 1795 568 3.31 / 142.18 2 3
4 13 145.56 21 15.31 530 170 3.48 / 142.35 2 3
5 8 0.00 175 15.31 276 739 4.22 / 143.09 2 2
Average= 4.09
(KJ/cycle)

Cycle 33 GMT 2/10/2020 22:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 29 15.24 469 207 0.21 / 134.73 2 3
2 7 2001.84 53 15.05 3158 2519 2.73 / 137.25 2 2
3 13 1004.28 21 15.08 1775 562 3.29 / 137.81 2 3
4 13 236.24 21 15.28 665 213 3.50 / 138.03 2 4
5 8 -0.04 175 15.31 276 739 4.24 / 138.77 2 3
6 14 -0.04 25 15.28 278 106 4.35 / 138.87 2 2
Average= 4.08
(KJ/cycle)

Cycle 32 GMT 23/ 9/2020 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 29 15.24 477 211 0.21 / 130.58 2 3
2 7 2003.72 52 15.05 3170 2481 2.69 / 133.06 2 2
3 13 993.28 21 15.09 1761 558 3.25 / 133.62 2 3
4 13 140.56 21 15.31 514 165 3.41 / 133.78 2 3
5 8 0.20 175 15.31 276 739 4.15 / 134.52 2 2
Average= 4.08
(KJ/cycle)

Cycle 31 GMT 13/ 9/2020 3: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 29 15.25 467 207 0.21 / 126.33 2 3
2 7 2006.36 53 15.05 3169 2528 2.73 / 128.86 2 2
3 13 996.76 21 15.08 1766 559 3.29 / 129.42 2 3
4 13 232.52 21 15.28 658 211 3.50 / 129.63 2 3
5 8 -0.20 175 15.31 277 742 4.25 / 130.37 2 2
Average= 4.07
(KJ/cycle)

Cycle 30 GMT 3/ 9/2020 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 29 15.26 450 199 0.20 / 122.21 2 3
2 7 2004.28 52 15.05 3178 2487 2.69 / 124.70 2 2
3 13 885.28 21 15.11 1604 509 3.20 / 125.21 2 3
4 13 155.44 21 15.31 540 174 3.37 / 125.38 2 3
5 8 0.36 175 15.31 276 739 4.11 / 126.12 2 2
Average= 4.07
(KJ/cycle)

Cycle 29 GMT 24/ 8/2020 7:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 29 15.25 468 207 0.21 / 118.05 2 3
2 7 2004.40 53 15.05 3163 2523 2.73 / 120.57 2 2
3 13 907.00 21 15.11 1634 518 3.25 / 121.09 2 3
4 13 173.48 21 15.30 567 182 3.43 / 121.27 2 4
5 8 -0.12 175 15.32 276 740 4.17 / 122.01 2 2
Average= 4.07
(KJ/cycle)

Cycle 28 GMT 14/ 8/2020 10: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 29 15.26 484 214 0.21 / 113.78 2 2
2 7 2009.04 52 15.06 3172 2484 2.70 / 116.27 2 3
3 13 1015.36 21 15.07 1788 566 3.26 / 116.83 2 3
4 13 136.48 21 15.32 509 164 3.43 / 117.00 2 3
5 8 0.20 175 15.31 277 742 4.17 / 117.74 2 3
6 14 0.20 25 15.29 278 106 4.28 / 117.84 2 2
Average= 4.06
(KJ/cycle)

Cycle 27 GMT 4/ 8/2020 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 29 15.26 468 207 0.21 / 109.54 2 3
2 7 2002.04 53 15.07 3154 2519 2.73 / 112.06 2 2
3 13 996.28 21 15.10 1765 560 3.29 / 112.62 2 3
4 13 224.32 21 15.30 648 208 3.49 / 112.82 2 3
5 8 0.00 175 15.33 277 743 4.24 / 113.57 2 2
Average= 4.06
(KJ/cycle)

Cycle 26 GMT 25/ 7/2020 14:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 29 15.26 476 211 0.21 / 105.19 2 3
2 7 2005.24 53 15.06 3169 2529 2.74 / 107.72 2 3
3 13 1005.72 21 15.09 1776 563 3.30 / 108.28 2 3
4 13 240.68 21 15.29 669 215 3.52 / 108.49 2 4
5 8 0.04 175 15.33 273 732 4.25 / 109.23 2 2
6 14 0.04 25 15.31 274 105 4.35 / 109.33 2 2
Average= 4.05
(KJ/cycle)

Cycle 25 GMT 15/ 7/2020 17:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 29 15.27 476 211 0.21 / 100.96 2 3
2 7 2003.84 53 15.06 3156 2519 2.73 / 103.48 2 2
3 13 991.12 21 15.10 1749 555 3.28 / 104.04 2 3
4 13 222.80 21 15.30 643 207 3.49 / 104.24 2 3
5 8 0.08 175 15.32 273 732 4.22 / 104.98 2 2
Average= 4.04
(KJ/cycle)

Cycle 24 GMT 5/ 7/2020 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 28 15.26 469 200 0.20 / 96.70 2 3
2 7 2008.28 53 15.08 3172 2535 2.74 / 99.23 2 2
3 13 991.24 21 15.12 1759 559 3.29 / 99.79 2 3
4 13 231.32 21 15.32 660 212 3.51 / 100.00 2 3
5 8 0.12 175 15.33 279 748 4.25 / 100.75 2 3
Average= 4.03
(KJ/cycle)

Cycle 23 GMT 25/ 6/2020 22:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 28 15.25 478 204 0.20 / 92.36 2 3
2 7 2004.68 53 15.07 3175 2536 2.74 / 94.90 2 2
3 13 997.92 21 15.11 1775 563 3.30 / 95.46 2 3
4 13 220.04 21 15.31 641 206 3.51 / 95.67 2 3
5 8 0.20 165 15.32 278 703 4.21 / 96.37 2 2
6 14 0.20 30 15.31 276 127 4.34 / 96.50 2 3
Average= 4.02
(KJ/cycle)

Cycle 22 GMT 16/ 6/2020 0:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 28 15.27 489 209 0.21 / 88.02 2 3
2 7 2002.76 53 15.08 3168 2532 2.74 / 90.55 2 2
3 13 1002.44 21 15.11 1775 563 3.30 / 91.11 2 3
4 13 232.16 21 15.31 659 212 3.52 / 91.32 2 3
5 8 -0.24 165 15.33 279 706 4.22 / 92.03 2 2
6 14 -0.24 30 15.31 281 129 4.35 / 92.16 2 3
Average= 4.01
(KJ/cycle)

Cycle 21 GMT 6/ 6/2020 3: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 28 15.27 448 192 0.19 / 83.79 2 3
2 7 2003.96 53 15.07 3167 2530 2.72 / 86.32 2 2
3 13 997.04 21 15.11 1774 563 3.28 / 86.88 2 3
4 13 232.24 21 15.32 660 212 3.50 / 87.10 2 3
5 8 0.24 165 15.33 281 711 4.21 / 87.81 2 2
Average= 3.99
(KJ/cycle)

Cycle 20 GMT 27/ 5/2020 5:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 28 15.28 469 201 0.20 / 79.53 2 3
2 7 2002.84 52 15.08 3157 2476 2.68 / 82.01 2 2
3 13 990.44 21 15.12 1763 560 3.24 / 82.57 2 3
4 13 219.20 21 15.32 644 207 3.44 / 82.77 2 3
5 8 0.04 165 15.34 277 701 4.14 / 83.47 2 3
6 14 0.04 30 15.32 274 126 4.27 / 83.60 2 4
Average= 3.98
(KJ/cycle)

Cycle 19 GMT 17/ 5/2020 7:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 28 15.27 444 190 0.19 / 75.33 2 3
2 7 2007.56 53 15.08 3166 2530 2.72 / 77.86 2 2
3 13 991.44 21 15.12 1757 558 3.28 / 78.42 2 3
4 13 224.32 21 15.32 651 209 3.49 / 78.63 2 4
5 8 0.08 165 15.34 277 701 4.19 / 79.33 2 3
Average= 3.97
(KJ/cycle)

Cycle 18 GMT 7/ 5/2020 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 28 15.27 475 203 0.20 / 71.09 3 3
2 7 2003.52 53 15.09 3164 2530 2.73 / 73.62 2 2
3 13 993.16 21 15.11 1756 557 3.29 / 74.18 2 3
4 13 364.00 21 15.28 853 274 3.56 / 74.45 2 3
5 8 0.04 165 15.33 272 688 4.25 / 75.14 2 2
Average= 3.95
(KJ/cycle)

Cycle 17 GMT 27/ 4/2020 12:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 28 15.28 450 193 0.19 / 66.94 2 3
2 7 2003.96 52 15.09 3172 2489 2.68 / 69.43 2 2
3 13 981.84 21 15.13 1736 552 3.23 / 69.98 2 3
4 13 208.00 21 15.33 623 201 3.43 / 70.19 2 3
5 8 -0.08 165 15.35 278 704 4.14 / 70.89 2 3
Average= 3.94
(KJ/cycle)

Cycle 16 GMT 17/ 4/2020 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 28 15.28 443 190 0.19 / 62.85 2 3
2 7 2002.40 53 15.08 3165 2530 2.72 / 65.38 2 2
3 13 869.24 21 15.16 1586 505 3.22 / 65.89 2 3
4 13 144.08 21 15.34 524 169 3.39 / 66.06 2 3
5 8 0.20 165 15.34 274 694 4.09 / 66.75 2 2
Average= 3.93
(KJ/cycle)

Cycle 15 GMT 7/ 4/2020 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 28 15.28 477 204 0.20 / 58.67 2 3
2 7 2006.48 53 15.08 3162 2527 2.73 / 61.19 2 2
3 13 993.32 21 15.13 1757 558 3.29 / 61.75 2 3
4 13 229.20 21 15.32 656 211 3.50 / 61.96 2 3
5 8 -0.08 165 15.34 277 701 4.20 / 62.67 2 2
Average= 3.92
(KJ/cycle)

Cycle 14 GMT 28/ 3/2020 20: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 28 15.28 473 202 0.20 / 54.47 2 3
2 7 2003.40 53 15.09 3170 2535 2.74 / 57.01 2 2
3 13 975.40 21 15.13 1734 551 3.29 / 57.56 2 3
4 13 198.80 21 15.34 611 197 3.49 / 57.75 2 3
5 8 0.08 165 15.35 280 709 4.19 / 58.46 2 2
Average= 3.90
(KJ/cycle)

Cycle 13 GMT 18/ 3/2020 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 28 15.30 467 200 0.20 / 50.35 3 3
2 7 2002.76 52 15.09 3160 2480 2.68 / 52.83 2 2
3 13 973.44 21 15.14 1724 548 3.23 / 53.38 2 3
4 13 193.88 21 15.34 604 195 3.42 / 53.57 2 3
5 8 0.12 165 15.35 276 699 4.12 / 54.27 2 2
Average= 3.88
(KJ/cycle)

Cycle 12 GMT 9/ 3/2020 0:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 28 15.27 465 199 0.20 / 46.17 2 3
2 7 2003.28 53 15.10 3159 2528 2.73 / 48.70 2 2
3 13 995.28 21 15.14 1755 558 3.28 / 49.25 2 3
4 13 220.72 21 15.33 636 205 3.49 / 49.46 2 3
5 8 -0.04 165 15.35 272 689 4.18 / 50.15 2 3
Average= 3.86
(KJ/cycle)

Cycle 11 GMT 28/ 2/2020 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 28 15.28 470 201 0.20 / 41.74 2 3
2 7 2010.76 53 15.10 3178 2543 2.74 / 44.29 2 2
3 13 985.72 21 15.14 1753 557 3.30 / 44.84 2 3
4 13 202.88 21 15.34 617 199 3.50 / 45.04 2 3
5 13 15.96 21 15.38 306 99 3.60 / 45.14 2 2
6 8 0.04 165 15.34 277 701 4.30 / 45.84 2 2
7 14 0.04 30 15.32 276 127 4.43 / 45.97 2 2
Average= 3.83
(KJ/cycle)

Cycle 10 GMT 18/ 2/2020 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 28 15.29 473 203 0.20 / 37.59 2 3
2 7 2003.40 52 15.11 3150 2475 2.68 / 40.06 2 2
3 13 980.40 19 15.16 1740 501 3.18 / 40.56 2 3
4 13 222.28 19 15.35 649 189 3.37 / 40.75 2 3
5 13 16.92 19 15.38 304 89 3.46 / 40.84 2 2
6 8 -0.04 165 15.35 277 702 4.16 / 41.54 2 2
Average= 3.78
(KJ/cycle)

Cycle 9 GMT 8/ 2/2020 8:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 27 15.30 472 195 0.19 / 33.42 2 3
2 3 1016.68 1 15.38 1886 29 0.22 / 33.45 2 2
3 7 2002.48 53 15.12 3153 2527 2.75 / 35.98 2 2
4 13 869.56 18 15.20 1575 431 3.18 / 36.41 2 3
5 13 274.52 18 15.34 717 198 3.38 / 36.61 2 3
6 13 22.92 18 15.41 310 86 3.47 / 36.69 2 2
7 8 -0.08 165 15.36 273 692 4.16 / 37.38 2 2
Average= 3.74
(KJ/cycle)

Cycle 8 GMT 29/ 1/2020 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 27 15.30 468 193 0.19 / 29.24 2 3
2 7 2003.04 53 15.11 3172 2540 2.73 / 31.78 2 2
3 13 967.68 18 15.16 1730 472 3.21 / 32.26 2 3
4 13 234.24 18 15.35 667 184 3.39 / 32.44 2 3
5 13 17.80 18 15.39 306 85 3.47 / 32.53 2 2
6 8 0.00 165 15.36 276 699 4.17 / 33.23 2 2
Average= 3.69
(KJ/cycle)

Cycle 7 GMT 19/ 1/2020 12:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 27 15.30 474 196 0.20 / 25.16 2 3
2 7 2004.16 53 15.10 3164 2532 2.73 / 27.69 2 2
3 13 982.12 18 15.15 1743 475 3.20 / 28.17 2 3
4 13 239.00 18 15.34 674 186 3.39 / 28.35 2 3
5 8 0.04 165 15.36 275 697 4.09 / 29.05 2 3
Average= 3.63
(KJ/cycle)

Cycle 6 GMT 9/ 1/2020 15: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 26 15.32 470 187 0.19 / 20.49 2 3
2 10 1022.56 2 15.29 1856 57 0.24 / 20.55 2 3
3 7 2003.04 75 14.83 3145 3498 3.74 / 24.05 2 2
4 13 294.24 18 15.33 761 210 3.95 / 24.26 2 3
5 8 0.16 165 15.36 279 707 4.66 / 24.97 2 2
Average= 3.57
(KJ/cycle)

Cycle 5 GMT 30/12/2019 17:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 25 15.31 463 177 0.18 / 15.96 2 3
2 10 1026.80 2 15.27 1869 57 0.23 / 16.02 2 3
3 7 2002.28 74 14.83 3126 3431 3.66 / 19.45 2 3
4 13 180.48 18 15.36 585 162 3.83 / 19.61 2 3
5 8 0.04 165 15.36 274 694 4.52 / 20.31 2 2
Average= 3.38
(KJ/cycle)

Cycle 4 GMT 20/12/2019 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 26 15.30 468 186 0.19 / 12.17 2 3
2 3 1026.00 1 15.36 1904 29 0.22 / 12.20 2 2
3 7 1526.48 74 15.00 2476 2748 2.96 / 14.95 2 3
4 13 111.84 18 15.37 472 131 3.09 / 15.08 2 3
5 8 0.00 165 15.37 278 705 3.80 / 15.79 2 2
Average= 3.16
(KJ/cycle)

Cycle 3 GMT 19/12/2019 20:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 28 15.31 467 200 0.20 / 8.45 2 3
2 3 929.52 -1 15.68 0 0 0.00 / 8.45 2 3
3 3 959.04 -1 15.70 0 0 0.00 / 8.45 2 3
4 7 1506.04 74 15.03 2436 2709 2.91 / 11.16 2 2
5 13 100.40 18 15.40 449 124 3.03 / 11.28 2 3
6 8 -0.08 165 15.38 277 703 3.74 / 11.99 2 2
Average= 3.00
(KJ/cycle)

Cycle 2 GMT 18/12/2019 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 26 15.35 462 184 0.18 / 4.70 2 3
2 7 1523.40 74 15.03 2450 2725 2.91 / 7.43 2 3
3 13 105.36 18 15.40 454 126 3.04 / 7.56 2 3
4 8 -0.04 165 15.39 273 693 3.73 / 8.25 2 2
Average= 2.75
(KJ/cycle)

Cycle 1 GMT 17/12/2019 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 23 15.49 432 154 0.15 / 1.82 3 3
2 10 1012.00 3 15.33 1820 84 0.24 / 1.91 2 3
3 7 997.28 74 15.21 1712 1927 2.16 / 3.83 2 3
4 8 0.00 165 15.42 270 687 2.85 / 4.52 2 2
Average= 2.26
(KJ/cycle)

Cycle 0 GMT 17/12/2019 11:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 136.44 22 15.64 480 165 0.17 / 0.17 3 3
2 7 149.84 74 15.60 483 558 0.72 / 0.72 3 3
3 8 0.16 240 15.58 253 946 1.67 / 1.67 3 6
Average= 1.67