SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.32 | 30 | 15.12 | 483 | 219 | 0.22 / 789.85 | 2 | 2 |
2 | 7 | 2010.52 | 53 | 14.97 | 3168 | 2514 | 2.73 / 792.36 | 2 | 2 |
3 | 13 | 1021.64 | 18 | 14.97 | 1798 | 484 | 3.22 / 792.84 | 2 | 3 |
4 | 13 | 442.20 | 18 | 15.11 | 970 | 264 | 3.48 / 793.11 | 2 | 4 |
5 | 13 | 24.40 | 18 | 15.23 | 334 | 92 | 3.57 / 793.20 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.19 | 286 | 717 | 4.29 / 793.92 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 30 | 15.11 | 478 | 217 | 0.22 / 785.60 | 2 | 2 |
2 | 7 | 2010.56 | 52 | 14.96 | 3165 | 2462 | 2.68 / 788.06 | 2 | 2 |
3 | 13 | 1031.24 | 18 | 14.96 | 1824 | 491 | 3.17 / 788.55 | 2 | 3 |
4 | 13 | 450.04 | 18 | 15.08 | 979 | 266 | 3.44 / 788.82 | 2 | 3 |
5 | 13 | 27.48 | 18 | 15.21 | 342 | 94 | 3.53 / 788.91 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.18 | 286 | 716 | 4.25 / 789.63 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 30 | 15.11 | 491 | 223 | 0.22 / 781.47 | 2 | 2 |
2 | 7 | 2007.68 | 53 | 14.94 | 3147 | 2492 | 2.71 / 783.96 | 2 | 2 |
3 | 13 | 1033.72 | 18 | 14.95 | 1822 | 490 | 3.20 / 784.45 | 2 | 3 |
4 | 13 | 331.40 | 18 | 15.13 | 809 | 220 | 3.43 / 784.67 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.18 | 285 | 714 | 4.14 / 785.38 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 30 | 15.12 | 482 | 219 | 0.22 / 777.30 | 2 | 2 |
2 | 7 | 2009.36 | 53 | 14.95 | 3177 | 2517 | 2.74 / 779.82 | 2 | 2 |
3 | 13 | 1023.04 | 18 | 14.96 | 1806 | 486 | 3.22 / 780.30 | 2 | 3 |
4 | 13 | 320.04 | 18 | 15.14 | 799 | 218 | 3.44 / 780.52 | 2 | 3 |
5 | 8 | -0.16 | 165 | 15.19 | 288 | 722 | 4.16 / 781.24 | 2 | 2 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.88 | 30 | 15.12 | 486 | 220 | 0.22 / 773.13 | 2 | 2 |
2 | 7 | 2008.72 | 53 | 14.97 | 3157 | 2505 | 2.73 / 775.63 | 2 | 2 |
3 | 13 | 1015.68 | 18 | 14.97 | 1792 | 483 | 3.21 / 776.11 | 2 | 4 |
4 | 13 | 420.56 | 18 | 15.11 | 938 | 255 | 3.46 / 776.37 | 2 | 4 |
5 | 8 | 0.08 | 165 | 15.20 | 284 | 712 | 4.18 / 777.08 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 30 | 15.13 | 459 | 208 | 0.21 / 768.81 | 2 | 2 |
2 | 7 | 2003.36 | 53 | 14.97 | 3148 | 2498 | 2.71 / 771.31 | 2 | 2 |
3 | 13 | 1015.68 | 18 | 14.99 | 1798 | 485 | 3.19 / 771.80 | 2 | 3 |
4 | 13 | 427.64 | 18 | 15.12 | 947 | 258 | 3.45 / 772.06 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.21 | 286 | 718 | 4.17 / 772.77 | 2 | 3 |
6 | 14 | 0.04 | 30 | 15.18 | 290 | 132 | 4.30 / 772.91 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 30 | 15.13 | 469 | 213 | 0.21 / 764.50 | 2 | 2 |
2 | 7 | 2009.56 | 53 | 14.97 | 3162 | 2509 | 2.72 / 767.01 | 2 | 2 |
3 | 13 | 1029.80 | 18 | 14.97 | 1814 | 489 | 3.21 / 767.50 | 2 | 4 |
4 | 13 | 444.64 | 18 | 15.11 | 970 | 264 | 3.47 / 767.76 | 2 | 5 |
5 | 8 | 0.40 | 165 | 15.19 | 285 | 714 | 4.19 / 768.48 | 2 | 2 |
6 | 14 | 0.40 | 30 | 15.16 | 286 | 130 | 4.32 / 768.61 | 2 | 4 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 30 | 15.13 | 487 | 221 | 0.22 / 760.17 | 2 | 2 |
2 | 7 | 2010.72 | 53 | 14.98 | 3163 | 2511 | 2.73 / 762.68 | 2 | 2 |
3 | 13 | 1030.04 | 18 | 14.98 | 1807 | 487 | 3.22 / 763.17 | 2 | 3 |
4 | 13 | 447.92 | 18 | 15.13 | 985 | 268 | 3.49 / 763.43 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.21 | 288 | 723 | 4.21 / 764.16 | 2 | 2 |
6 | 14 | 0.04 | 30 | 15.17 | 288 | 131 | 4.34 / 764.29 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 30 | 15.14 | 498 | 226 | 0.23 / 756.01 | 2 | 2 |
2 | 7 | 2010.96 | 53 | 14.98 | 3158 | 2507 | 2.73 / 758.52 | 2 | 2 |
3 | 13 | 1032.96 | 18 | 14.99 | 1817 | 490 | 3.22 / 759.01 | 2 | 3 |
4 | 13 | 326.16 | 18 | 15.15 | 803 | 219 | 3.44 / 759.23 | 2 | 3 |
5 | 8 | -0.08 | 165 | 15.20 | 287 | 720 | 4.16 / 759.95 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 30 | 15.14 | 485 | 220 | 0.22 / 751.87 | 2 | 2 |
2 | 7 | 2008.12 | 52 | 14.98 | 3166 | 2466 | 2.69 / 754.34 | 2 | 2 |
3 | 13 | 1035.80 | 18 | 14.97 | 1829 | 493 | 3.18 / 754.83 | 2 | 3 |
4 | 13 | 330.60 | 18 | 15.16 | 814 | 222 | 3.40 / 755.05 | 2 | 4 |
5 | 8 | -0.08 | 165 | 15.21 | 291 | 730 | 4.13 / 755.78 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 30 | 15.13 | 460 | 209 | 0.21 / 747.67 | 2 | 2 |
2 | 7 | 2003.68 | 53 | 14.99 | 3154 | 2506 | 2.71 / 750.17 | 2 | 2 |
3 | 13 | 1044.80 | 18 | 14.98 | 1837 | 495 | 3.21 / 750.67 | 2 | 4 |
4 | 13 | 439.60 | 18 | 15.11 | 966 | 263 | 3.47 / 750.93 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.21 | 288 | 723 | 4.20 / 751.65 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 30 | 15.12 | 482 | 219 | 0.22 / 743.49 | 2 | 2 |
2 | 7 | 2006.76 | 53 | 14.98 | 3158 | 2507 | 2.73 / 745.99 | 2 | 2 |
3 | 13 | 1012.12 | 18 | 14.98 | 1790 | 483 | 3.21 / 746.48 | 2 | 4 |
4 | 13 | 423.96 | 18 | 15.13 | 949 | 258 | 3.47 / 746.74 | 2 | 3 |
5 | 8 | 0.24 | 165 | 15.22 | 287 | 721 | 4.19 / 747.46 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.88 | 30 | 15.12 | 482 | 219 | 0.22 / 739.38 | 2 | 2 |
2 | 7 | 2010.32 | 52 | 14.96 | 3167 | 2464 | 2.68 / 741.84 | 2 | 2 |
3 | 13 | 1033.72 | 18 | 14.97 | 1816 | 489 | 3.17 / 742.33 | 2 | 3 |
4 | 13 | 331.96 | 18 | 15.14 | 811 | 221 | 3.39 / 742.55 | 2 | 4 |
5 | 8 | 0.20 | 165 | 15.19 | 285 | 714 | 4.11 / 743.27 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 30 | 15.11 | 481 | 218 | 0.22 / 735.06 | 2 | 2 |
2 | 7 | 2010.68 | 53 | 14.97 | 3157 | 2505 | 2.72 / 737.57 | 2 | 2 |
3 | 13 | 1013.40 | 18 | 14.97 | 1780 | 480 | 3.20 / 738.04 | 2 | 3 |
4 | 13 | 423.68 | 18 | 15.12 | 944 | 257 | 3.46 / 738.30 | 2 | 4 |
5 | 8 | 0.44 | 165 | 15.20 | 290 | 727 | 4.19 / 739.03 | 2 | 2 |
6 | 14 | 0.44 | 30 | 15.17 | 292 | 133 | 4.32 / 739.16 | 3 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 30 | 15.14 | 477 | 217 | 0.22 / 730.86 | 2 | 2 |
2 | 7 | 2010.32 | 53 | 14.95 | 3158 | 2502 | 2.72 / 733.37 | 2 | 2 |
3 | 13 | 1050.80 | 18 | 14.97 | 1837 | 495 | 3.21 / 733.86 | 2 | 3 |
4 | 13 | 466.52 | 18 | 15.10 | 1001 | 272 | 3.49 / 734.13 | 2 | 4 |
5 | 8 | -0.04 | 165 | 15.19 | 283 | 709 | 4.20 / 734.84 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 30 | 15.13 | 484 | 220 | 0.22 / 726.53 | 2 | 2 |
2 | 7 | 2005.08 | 53 | 14.97 | 3155 | 2503 | 2.72 / 729.04 | 2 | 2 |
3 | 13 | 1029.60 | 18 | 14.98 | 1817 | 490 | 3.21 / 729.53 | 2 | 4 |
4 | 13 | 448.24 | 18 | 15.13 | 979 | 267 | 3.48 / 729.79 | 2 | 4 |
5 | 8 | -0.04 | 165 | 15.20 | 288 | 722 | 4.20 / 730.52 | 2 | 2 |
6 | 14 | -0.04 | 30 | 15.18 | 287 | 131 | 4.33 / 730.65 | 2 | 2 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.64 | 30 | 15.14 | 482 | 219 | 0.22 / 722.34 | 2 | 2 |
2 | 7 | 2004.60 | 53 | 14.98 | 3152 | 2502 | 2.72 / 724.84 | 2 | 2 |
3 | 13 | 1021.08 | 18 | 14.99 | 1803 | 486 | 3.21 / 725.33 | 2 | 3 |
4 | 13 | 437.72 | 18 | 15.12 | 965 | 263 | 3.47 / 725.59 | 2 | 4 |
5 | 8 | 0.12 | 165 | 15.21 | 289 | 725 | 4.20 / 726.31 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 30 | 15.14 | 458 | 208 | 0.21 / 718.15 | 2 | 3 |
2 | 7 | 2003.64 | 53 | 14.99 | 3156 | 2507 | 2.72 / 720.66 | 2 | 2 |
3 | 13 | 1018.92 | 18 | 15.00 | 1796 | 485 | 3.20 / 721.14 | 2 | 3 |
4 | 13 | 439.36 | 18 | 15.15 | 965 | 263 | 3.46 / 721.41 | 2 | 4 |
5 | 8 | 0.24 | 165 | 15.21 | 284 | 713 | 4.18 / 722.12 | 2 | 4 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 30 | 15.11 | 462 | 209 | 0.21 / 714.00 | 2 | 2 |
2 | 7 | 2009.44 | 52 | 14.98 | 3164 | 2465 | 2.67 / 716.47 | 2 | 2 |
3 | 13 | 1036.76 | 18 | 14.96 | 1823 | 491 | 3.16 / 716.96 | 2 | 3 |
4 | 13 | 447.20 | 18 | 15.11 | 978 | 266 | 3.43 / 717.23 | 2 | 4 |
5 | 8 | 0.08 | 165 | 15.20 | 286 | 717 | 4.15 / 717.94 | 2 | 2 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 30 | 15.12 | 483 | 219 | 0.22 / 709.59 | 2 | 2 |
2 | 7 | 2010.48 | 53 | 14.97 | 3167 | 2513 | 2.73 / 712.10 | 2 | 2 |
3 | 13 | 1026.20 | 18 | 14.99 | 1803 | 486 | 3.22 / 712.59 | 2 | 3 |
4 | 13 | 431.04 | 18 | 15.13 | 952 | 259 | 3.48 / 712.84 | 2 | 3 |
5 | 13 | 53.72 | 18 | 15.21 | 386 | 106 | 3.58 / 712.95 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.18 | 285 | 714 | 4.30 / 713.66 | 2 | 3 |
7 | 14 | -0.08 | 30 | 15.16 | 286 | 130 | 4.43 / 713.79 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 30 | 15.13 | 456 | 207 | 0.21 / 705.34 | 2 | 2 |
2 | 7 | 2008.48 | 52 | 14.96 | 3153 | 2453 | 2.66 / 707.80 | 2 | 2 |
3 | 13 | 1037.16 | 18 | 14.96 | 1820 | 490 | 3.15 / 708.29 | 2 | 3 |
4 | 13 | 460.44 | 18 | 15.10 | 996 | 271 | 3.42 / 708.56 | 2 | 3 |
5 | 13 | 32.68 | 18 | 15.22 | 348 | 95 | 3.52 / 708.65 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.18 | 285 | 714 | 4.23 / 709.37 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 30 | 15.12 | 482 | 219 | 0.22 / 701.04 | 2 | 2 |
2 | 7 | 2008.20 | 53 | 14.96 | 3151 | 2498 | 2.72 / 703.54 | 2 | 2 |
3 | 13 | 1026.08 | 18 | 14.98 | 1800 | 485 | 3.20 / 704.02 | 2 | 3 |
4 | 13 | 442.12 | 18 | 15.11 | 967 | 263 | 3.47 / 704.28 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.19 | 288 | 722 | 4.19 / 705.01 | 2 | 3 |
6 | 14 | 0.16 | 30 | 15.16 | 290 | 132 | 4.32 / 705.14 | 2 | 4 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.68 | 30 | 15.11 | 479 | 217 | 0.22 / 696.74 | 2 | 2 |
2 | 7 | 2010.64 | 53 | 14.98 | 3162 | 2510 | 2.73 / 699.25 | 2 | 2 |
3 | 13 | 1027.48 | 18 | 14.99 | 1804 | 487 | 3.21 / 699.74 | 2 | 4 |
4 | 13 | 431.08 | 18 | 15.14 | 955 | 260 | 3.47 / 700.00 | 2 | 4 |
5 | 13 | 52.00 | 18 | 15.24 | 383 | 105 | 3.58 / 700.10 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.21 | 285 | 715 | 4.29 / 700.82 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 30 | 15.13 | 460 | 209 | 0.21 / 692.45 | 2 | 2 |
2 | 7 | 2007.28 | 53 | 14.96 | 3151 | 2498 | 2.71 / 694.95 | 2 | 2 |
3 | 13 | 1036.24 | 18 | 14.97 | 1817 | 490 | 3.20 / 695.44 | 2 | 3 |
4 | 13 | 444.04 | 18 | 15.11 | 974 | 265 | 3.46 / 695.70 | 2 | 4 |
5 | 13 | 50.48 | 18 | 15.22 | 382 | 105 | 3.57 / 695.81 | 2 | 3 |
6 | 8 | -0.20 | 165 | 15.18 | 286 | 716 | 4.28 / 696.52 | 2 | 3 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 30 | 15.12 | 476 | 216 | 0.22 / 688.16 | 2 | 2 |
2 | 7 | 2004.36 | 53 | 14.98 | 3158 | 2507 | 2.72 / 690.67 | 2 | 2 |
3 | 13 | 1047.24 | 18 | 14.98 | 1834 | 495 | 3.22 / 691.16 | 2 | 4 |
4 | 13 | 451.64 | 18 | 15.11 | 988 | 269 | 3.49 / 691.43 | 2 | 3 |
5 | 13 | 30.00 | 18 | 15.24 | 349 | 96 | 3.58 / 691.53 | 2 | 3 |
6 | 8 | 0.40 | 165 | 15.20 | 285 | 715 | 4.30 / 692.24 | 2 | 4 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 30 | 15.12 | 477 | 216 | 0.22 / 683.77 | 2 | 2 |
2 | 7 | 2008.16 | 52 | 14.98 | 3159 | 2461 | 2.68 / 686.23 | 2 | 2 |
3 | 13 | 1020.60 | 18 | 14.98 | 1795 | 484 | 3.16 / 686.72 | 2 | 4 |
4 | 13 | 439.04 | 18 | 15.13 | 965 | 263 | 3.42 / 686.98 | 2 | 3 |
5 | 13 | 55.40 | 18 | 15.22 | 390 | 107 | 3.53 / 687.09 | 2 | 3 |
6 | 8 | -0.36 | 165 | 15.19 | 290 | 727 | 4.26 / 687.81 | 2 | 3 |
7 | 14 | -0.36 | 30 | 15.17 | 290 | 132 | 4.39 / 687.94 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 30 | 15.13 | 483 | 219 | 0.22 / 679.57 | 2 | 2 |
2 | 7 | 2003.72 | 53 | 14.95 | 3134 | 2483 | 2.70 / 682.05 | 2 | 2 |
3 | 13 | 1010.88 | 18 | 14.99 | 1782 | 481 | 3.18 / 682.53 | 2 | 3 |
4 | 13 | 297.04 | 18 | 15.16 | 758 | 207 | 3.39 / 682.74 | 2 | 3 |
5 | 13 | 39.48 | 18 | 15.23 | 361 | 99 | 3.49 / 682.84 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.20 | 286 | 717 | 4.21 / 683.55 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 30 | 15.13 | 453 | 206 | 0.21 / 675.31 | 2 | 2 |
2 | 7 | 2008.12 | 52 | 14.98 | 3167 | 2467 | 2.67 / 677.78 | 2 | 2 |
3 | 13 | 1033.36 | 18 | 14.98 | 1814 | 489 | 3.16 / 678.27 | 2 | 3 |
4 | 13 | 446.44 | 18 | 15.13 | 976 | 266 | 3.43 / 678.54 | 2 | 4 |
5 | 13 | 32.92 | 18 | 15.22 | 348 | 95 | 3.52 / 678.63 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.19 | 286 | 717 | 4.24 / 679.35 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 30 | 15.14 | 479 | 218 | 0.22 / 671.04 | 2 | 2 |
2 | 7 | 2008.04 | 53 | 14.98 | 3167 | 2514 | 2.73 / 673.55 | 2 | 2 |
3 | 13 | 1018.68 | 18 | 14.99 | 1796 | 485 | 3.22 / 674.04 | 2 | 3 |
4 | 13 | 440.76 | 18 | 15.14 | 964 | 263 | 3.48 / 674.30 | 2 | 4 |
5 | 13 | 30.36 | 18 | 15.24 | 349 | 96 | 3.58 / 674.40 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.19 | 284 | 712 | 4.29 / 675.11 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 30 | 15.14 | 447 | 203 | 0.20 / 666.84 | 2 | 2 |
2 | 7 | 2007.04 | 52 | 14.99 | 3166 | 2468 | 2.67 / 669.31 | 2 | 2 |
3 | 13 | 1025.04 | 18 | 15.00 | 1806 | 488 | 3.16 / 669.79 | 2 | 4 |
4 | 13 | 311.80 | 18 | 15.18 | 780 | 213 | 3.37 / 670.01 | 2 | 3 |
5 | 13 | 34.80 | 18 | 15.25 | 356 | 98 | 3.47 / 670.11 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.22 | 285 | 716 | 4.19 / 670.82 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 30 | 15.12 | 466 | 211 | 0.21 / 662.44 | 2 | 3 |
2 | 7 | 2009.72 | 53 | 14.98 | 3162 | 2510 | 2.72 / 664.95 | 2 | 2 |
3 | 13 | 1017.16 | 18 | 15.00 | 1793 | 484 | 3.21 / 665.44 | 2 | 3 |
4 | 13 | 427.92 | 18 | 15.14 | 949 | 259 | 3.46 / 665.70 | 2 | 4 |
5 | 13 | 29.16 | 18 | 15.24 | 344 | 94 | 3.56 / 665.79 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.19 | 286 | 717 | 4.28 / 666.51 | 2 | 6 |
7 | 14 | 0.08 | 30 | 15.16 | 284 | 129 | 4.40 / 666.64 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 30 | 15.12 | 459 | 208 | 0.21 / 658.17 | 2 | 2 |
2 | 7 | 2008.12 | 53 | 14.97 | 3154 | 2502 | 2.71 / 660.67 | 2 | 2 |
3 | 13 | 1020.32 | 18 | 15.00 | 1795 | 485 | 3.20 / 661.15 | 2 | 3 |
4 | 13 | 438.68 | 18 | 15.12 | 962 | 262 | 3.46 / 661.42 | 2 | 3 |
5 | 13 | 25.32 | 18 | 15.23 | 336 | 92 | 3.55 / 661.51 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.21 | 288 | 723 | 4.27 / 662.23 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 30 | 15.12 | 467 | 212 | 0.21 / 653.92 | 2 | 2 |
2 | 7 | 2012.52 | 52 | 14.97 | 3169 | 2467 | 2.68 / 656.39 | 2 | 2 |
3 | 13 | 1033.28 | 18 | 14.98 | 1815 | 489 | 3.17 / 656.88 | 2 | 3 |
4 | 13 | 450.04 | 18 | 15.13 | 979 | 267 | 3.43 / 657.14 | 2 | 4 |
5 | 13 | 28.56 | 18 | 15.23 | 341 | 93 | 3.53 / 657.24 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.20 | 288 | 722 | 4.25 / 657.96 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 30 | 15.13 | 479 | 217 | 0.22 / 649.55 | 2 | 2 |
2 | 7 | 2010.44 | 53 | 14.99 | 3160 | 2511 | 2.73 / 652.06 | 2 | 2 |
3 | 13 | 1022.56 | 18 | 14.99 | 1805 | 487 | 3.21 / 652.55 | 2 | 4 |
4 | 13 | 309.80 | 18 | 15.18 | 777 | 212 | 3.43 / 652.76 | 2 | 3 |
5 | 13 | 37.96 | 18 | 15.25 | 361 | 99 | 3.53 / 652.86 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.22 | 286 | 718 | 4.24 / 653.58 | 2 | 3 |
7 | 14 | -0.08 | 30 | 15.19 | 288 | 131 | 4.38 / 653.71 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 30 | 15.14 | 458 | 208 | 0.21 / 645.25 | 2 | 2 |
2 | 7 | 2006.00 | 53 | 14.99 | 3160 | 2511 | 2.72 / 647.76 | 2 | 2 |
3 | 13 | 1026.68 | 18 | 14.99 | 1808 | 488 | 3.21 / 648.25 | 2 | 4 |
4 | 13 | 426.76 | 18 | 15.14 | 947 | 258 | 3.46 / 648.51 | 2 | 4 |
5 | 13 | 29.92 | 18 | 15.25 | 352 | 97 | 3.56 / 648.60 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.21 | 291 | 730 | 4.29 / 649.33 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.60 | 30 | 15.14 | 481 | 218 | 0.22 / 640.97 | 2 | 3 |
2 | 7 | 2004.76 | 53 | 14.99 | 3159 | 2510 | 2.73 / 643.48 | 2 | 2 |
3 | 13 | 1022.52 | 18 | 14.99 | 1802 | 486 | 3.21 / 643.97 | 2 | 3 |
4 | 13 | 431.68 | 18 | 15.15 | 955 | 260 | 3.47 / 644.23 | 2 | 3 |
5 | 13 | 29.44 | 18 | 15.24 | 347 | 95 | 3.57 / 644.32 | 2 | 2 |
6 | 8 | 0.16 | 165 | 15.20 | 287 | 720 | 4.29 / 645.04 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 30 | 15.15 | 460 | 209 | 0.21 / 636.67 | 2 | 2 |
2 | 7 | 2009.08 | 53 | 15.00 | 3157 | 2510 | 2.72 / 639.17 | 2 | 2 |
3 | 13 | 1036.80 | 18 | 14.98 | 1821 | 491 | 3.21 / 639.67 | 2 | 3 |
4 | 13 | 454.24 | 18 | 15.14 | 988 | 269 | 3.48 / 639.94 | 2 | 3 |
5 | 13 | 15.76 | 18 | 15.26 | 324 | 89 | 3.57 / 640.02 | 2 | 2 |
6 | 8 | -0.20 | 165 | 15.21 | 290 | 728 | 4.30 / 640.75 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 30 | 15.15 | 491 | 223 | 0.22 / 632.36 | 2 | 2 |
2 | 7 | 2010.92 | 53 | 14.99 | 3167 | 2516 | 2.74 / 634.88 | 2 | 2 |
3 | 13 | 1034.92 | 18 | 15.00 | 1825 | 493 | 3.23 / 635.37 | 2 | 4 |
4 | 13 | 435.48 | 18 | 15.15 | 958 | 261 | 3.49 / 635.63 | 2 | 4 |
5 | 13 | 24.84 | 18 | 15.25 | 345 | 95 | 3.59 / 635.73 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.22 | 290 | 728 | 4.32 / 636.46 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 30 | 15.16 | 495 | 225 | 0.23 / 628.05 | 2 | 2 |
2 | 7 | 2009.24 | 53 | 14.99 | 3169 | 2518 | 2.74 / 630.56 | 2 | 2 |
3 | 13 | 1029.92 | 18 | 15.00 | 1817 | 491 | 3.23 / 631.06 | 2 | 3 |
4 | 13 | 439.08 | 18 | 15.14 | 965 | 263 | 3.50 / 631.32 | 2 | 5 |
5 | 13 | 26.20 | 18 | 15.26 | 346 | 95 | 3.59 / 631.41 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.23 | 289 | 726 | 4.32 / 632.14 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 30 | 15.16 | 484 | 220 | 0.22 / 623.82 | 2 | 3 |
2 | 7 | 2011.04 | 53 | 14.99 | 3161 | 2511 | 2.73 / 626.33 | 2 | 2 |
3 | 13 | 1021.96 | 18 | 14.99 | 1803 | 486 | 3.22 / 626.82 | 2 | 3 |
4 | 13 | 446.76 | 18 | 15.14 | 981 | 267 | 3.49 / 627.09 | 2 | 4 |
5 | 8 | 0.24 | 165 | 15.22 | 293 | 736 | 4.22 / 627.82 | 2 | 2 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.68 | 30 | 15.17 | 493 | 224 | 0.22 / 619.51 | 2 | 2 |
2 | 7 | 2005.44 | 52 | 14.99 | 3169 | 2470 | 2.69 / 621.98 | 2 | 2 |
3 | 13 | 1024.52 | 18 | 15.01 | 1810 | 489 | 3.18 / 622.47 | 2 | 4 |
4 | 13 | 443.24 | 18 | 15.15 | 973 | 265 | 3.45 / 622.74 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.24 | 291 | 732 | 4.18 / 623.47 | 2 | 3 |
6 | 14 | 0.00 | 30 | 15.22 | 291 | 133 | 4.31 / 623.60 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 30 | 15.16 | 495 | 225 | 0.23 / 615.29 | 2 | 3 |
2 | 7 | 2004.12 | 53 | 14.99 | 3171 | 2519 | 2.74 / 617.81 | 2 | 2 |
3 | 13 | 1013.28 | 18 | 15.02 | 1799 | 486 | 3.23 / 618.30 | 2 | 3 |
4 | 13 | 421.64 | 18 | 15.16 | 944 | 258 | 3.49 / 618.55 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.24 | 292 | 734 | 4.22 / 619.29 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 30 | 15.15 | 484 | 220 | 0.22 / 611.11 | 2 | 2 |
2 | 7 | 2006.96 | 53 | 15.00 | 3161 | 2513 | 2.73 / 613.63 | 2 | 2 |
3 | 13 | 1030.24 | 18 | 15.01 | 1812 | 490 | 3.22 / 614.12 | 2 | 3 |
4 | 13 | 314.36 | 18 | 15.19 | 789 | 216 | 3.44 / 614.33 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.23 | 292 | 734 | 4.17 / 615.06 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 30 | 15.17 | 500 | 228 | 0.23 / 606.77 | 2 | 2 |
2 | 7 | 2004.52 | 53 | 15.00 | 3156 | 2509 | 2.74 / 609.28 | 2 | 2 |
3 | 13 | 1021.44 | 18 | 14.99 | 1799 | 485 | 3.22 / 609.77 | 2 | 3 |
4 | 13 | 437.88 | 18 | 15.14 | 966 | 263 | 3.49 / 610.03 | 2 | 3 |
5 | 8 | 0.24 | 165 | 15.22 | 290 | 728 | 4.21 / 610.76 | 2 | 2 |
6 | 14 | 0.24 | 30 | 15.20 | 291 | 133 | 4.35 / 610.89 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 30 | 15.16 | 486 | 221 | 0.22 / 602.42 | 2 | 4 |
2 | 7 | 2009.64 | 53 | 14.98 | 3164 | 2512 | 2.73 / 604.93 | 2 | 2 |
3 | 13 | 1022.24 | 18 | 15.00 | 1805 | 487 | 3.22 / 605.42 | 2 | 4 |
4 | 13 | 429.48 | 18 | 15.15 | 954 | 260 | 3.48 / 605.68 | 2 | 4 |
5 | 8 | -0.04 | 165 | 15.23 | 292 | 734 | 4.21 / 606.41 | 2 | 3 |
6 | 14 | -0.04 | 30 | 15.20 | 296 | 135 | 4.35 / 606.55 | 2 | 4 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.92 | 30 | 15.16 | 496 | 226 | 0.23 / 598.20 | 2 | 2 |
2 | 7 | 2005.64 | 53 | 15.01 | 3163 | 2516 | 2.74 / 600.72 | 2 | 2 |
3 | 13 | 1029.28 | 18 | 15.00 | 1812 | 489 | 3.23 / 601.21 | 2 | 3 |
4 | 13 | 438.48 | 18 | 15.15 | 963 | 263 | 3.49 / 601.47 | 2 | 4 |
5 | 8 | -0.04 | 165 | 15.22 | 290 | 728 | 4.22 / 602.20 | 2 | 2 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.24 | 30 | 15.17 | 491 | 223 | 0.22 / 593.98 | 2 | 2 |
2 | 7 | 2007.68 | 53 | 14.99 | 3168 | 2517 | 2.74 / 596.50 | 2 | 2 |
3 | 13 | 1022.72 | 18 | 15.01 | 1796 | 485 | 3.23 / 596.98 | 2 | 3 |
4 | 13 | 424.40 | 18 | 15.17 | 945 | 258 | 3.48 / 597.24 | 2 | 4 |
5 | 8 | 0.56 | 165 | 15.24 | 292 | 734 | 4.22 / 597.98 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 30 | 15.16 | 480 | 218 | 0.22 / 589.68 | 2 | 2 |
2 | 7 | 2007.68 | 52 | 14.99 | 3151 | 2456 | 2.67 / 592.14 | 2 | 2 |
3 | 13 | 1036.68 | 18 | 15.02 | 1822 | 493 | 3.17 / 592.63 | 2 | 3 |
4 | 13 | 451.28 | 18 | 15.16 | 985 | 269 | 3.44 / 592.90 | 2 | 4 |
5 | 8 | -0.16 | 165 | 15.24 | 289 | 727 | 4.16 / 593.62 | 2 | 3 |
6 | 14 | -0.16 | 30 | 15.22 | 292 | 133 | 4.30 / 593.76 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 30 | 15.16 | 465 | 211 | 0.21 / 585.34 | 2 | 2 |
2 | 7 | 2006.28 | 53 | 15.01 | 3155 | 2510 | 2.72 / 587.85 | 2 | 2 |
3 | 13 | 1037.16 | 18 | 14.99 | 1817 | 490 | 3.21 / 588.34 | 2 | 3 |
4 | 13 | 451.48 | 18 | 15.15 | 981 | 268 | 3.48 / 588.60 | 2 | 4 |
5 | 8 | 0.24 | 165 | 15.23 | 289 | 726 | 4.21 / 589.33 | 2 | 2 |
6 | 14 | 0.24 | 30 | 15.21 | 289 | 132 | 4.34 / 589.46 | 2 | 4 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 30 | 15.15 | 474 | 215 | 0.22 / 580.95 | 2 | 2 |
2 | 7 | 2006.60 | 52 | 15.00 | 3167 | 2470 | 2.69 / 583.42 | 2 | 2 |
3 | 13 | 1014.16 | 18 | 15.02 | 1792 | 484 | 3.17 / 583.91 | 2 | 3 |
4 | 13 | 436.76 | 18 | 15.16 | 964 | 263 | 3.43 / 584.17 | 2 | 3 |
5 | 13 | 29.36 | 18 | 15.26 | 343 | 94 | 3.53 / 584.26 | 2 | 2 |
6 | 8 | 0.20 | 165 | 15.23 | 290 | 729 | 4.26 / 584.99 | 2 | 3 |
7 | 14 | 0.20 | 30 | 15.21 | 291 | 133 | 4.39 / 585.12 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 30 | 15.15 | 479 | 218 | 0.22 / 576.65 | 2 | 2 |
2 | 7 | 2008.40 | 53 | 15.00 | 3163 | 2515 | 2.73 / 579.16 | 2 | 2 |
3 | 13 | 1033.32 | 18 | 15.01 | 1818 | 491 | 3.22 / 579.65 | 2 | 4 |
4 | 13 | 444.88 | 18 | 15.16 | 971 | 265 | 3.49 / 579.92 | 2 | 4 |
5 | 13 | 25.44 | 18 | 15.26 | 336 | 92 | 3.58 / 580.01 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.22 | 288 | 723 | 4.30 / 580.74 | 2 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 30 | 15.17 | 483 | 220 | 0.22 / 572.41 | 2 | 2 |
2 | 7 | 2006.44 | 52 | 15.01 | 3162 | 2468 | 2.69 / 574.87 | 2 | 2 |
3 | 13 | 1029.72 | 18 | 15.00 | 1811 | 489 | 3.18 / 575.36 | 2 | 3 |
4 | 13 | 330.88 | 18 | 15.18 | 807 | 221 | 3.40 / 575.58 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.23 | 286 | 719 | 4.12 / 576.30 | 2 | 3 |
6 | 14 | 0.16 | 30 | 15.20 | 285 | 130 | 4.25 / 576.43 | 2 | 4 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 30 | 15.16 | 484 | 220 | 0.22 / 568.21 | 2 | 2 |
2 | 7 | 2008.60 | 53 | 15.00 | 3155 | 2508 | 2.73 / 570.72 | 2 | 2 |
3 | 13 | 1030.96 | 18 | 15.01 | 1812 | 490 | 3.22 / 571.20 | 2 | 3 |
4 | 13 | 427.28 | 18 | 15.16 | 948 | 259 | 3.48 / 571.46 | 2 | 4 |
5 | 8 | -0.08 | 165 | 15.24 | 287 | 722 | 4.20 / 572.19 | 2 | 2 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 30 | 15.17 | 484 | 220 | 0.22 / 563.96 | 2 | 2 |
2 | 7 | 2005.28 | 52 | 14.99 | 3164 | 2466 | 2.69 / 566.42 | 2 | 2 |
3 | 13 | 1035.12 | 18 | 15.00 | 1822 | 492 | 3.18 / 566.92 | 2 | 3 |
4 | 13 | 317.20 | 18 | 15.18 | 791 | 216 | 3.39 / 567.13 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.23 | 288 | 724 | 4.12 / 567.86 | 2 | 3 |
6 | 14 | 0.04 | 30 | 15.20 | 286 | 130 | 4.25 / 567.99 | 2 | 4 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 30 | 15.17 | 454 | 207 | 0.21 / 559.52 | 2 | 3 |
2 | 7 | 2005.92 | 53 | 15.01 | 3151 | 2507 | 2.71 / 562.03 | 2 | 2 |
3 | 13 | 1025.84 | 18 | 15.03 | 1810 | 490 | 3.20 / 562.52 | 2 | 3 |
4 | 13 | 434.56 | 18 | 15.17 | 958 | 262 | 3.46 / 562.78 | 2 | 4 |
5 | 13 | 54.68 | 18 | 15.26 | 391 | 107 | 3.57 / 562.88 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.23 | 287 | 721 | 4.29 / 563.61 | 2 | 6 |
7 | 14 | 0.24 | 30 | 15.21 | 290 | 132 | 4.43 / 563.74 | 3 | 3 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 30 | 15.17 | 465 | 212 | 0.21 / 555.28 | 2 | 2 |
2 | 7 | 2002.48 | 53 | 15.00 | 3137 | 2494 | 2.71 / 557.77 | 2 | 2 |
3 | 13 | 1019.40 | 18 | 15.01 | 1794 | 485 | 3.19 / 558.26 | 2 | 4 |
4 | 13 | 310.20 | 18 | 15.19 | 778 | 213 | 3.40 / 558.47 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.22 | 284 | 713 | 4.12 / 559.18 | 2 | 3 |
6 | 14 | 0.08 | 30 | 15.20 | 284 | 130 | 4.25 / 559.31 | 2 | 3 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 30 | 15.18 | 471 | 214 | 0.21 / 550.84 | 2 | 2 |
2 | 7 | 2011.64 | 53 | 15.02 | 3167 | 2521 | 2.74 / 553.36 | 2 | 2 |
3 | 13 | 1025.88 | 18 | 15.02 | 1805 | 488 | 3.22 / 553.85 | 2 | 4 |
4 | 13 | 433.00 | 18 | 15.17 | 953 | 260 | 3.48 / 554.11 | 2 | 4 |
5 | 13 | 58.96 | 18 | 15.27 | 396 | 109 | 3.59 / 554.22 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.25 | 285 | 717 | 4.31 / 554.94 | 2 | 3 |
7 | 14 | 0.20 | 30 | 15.22 | 286 | 131 | 4.44 / 555.07 | 2 | 4 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 30 | 15.17 | 460 | 209 | 0.21 / 546.49 | 2 | 2 |
2 | 7 | 2007.96 | 52 | 15.02 | 3174 | 2479 | 2.69 / 548.97 | 2 | 2 |
3 | 13 | 1023.68 | 18 | 15.03 | 1802 | 488 | 3.18 / 549.45 | 2 | 3 |
4 | 13 | 314.40 | 18 | 15.20 | 790 | 216 | 3.39 / 549.67 | 2 | 4 |
5 | 13 | 34.36 | 18 | 15.27 | 357 | 98 | 3.49 / 549.77 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.23 | 289 | 726 | 4.22 / 550.49 | 2 | 5 |
7 | 14 | 0.16 | 30 | 15.21 | 289 | 132 | 4.35 / 550.63 | 2 | 5 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 30 | 15.15 | 471 | 214 | 0.21 / 542.25 | 2 | 2 |
2 | 7 | 2005.80 | 52 | 15.01 | 3152 | 2460 | 2.67 / 544.71 | 2 | 2 |
3 | 13 | 1022.96 | 18 | 15.04 | 1802 | 488 | 3.16 / 545.20 | 2 | 3 |
4 | 13 | 432.84 | 18 | 15.16 | 952 | 260 | 3.42 / 545.46 | 2 | 3 |
5 | 13 | 49.84 | 18 | 15.26 | 379 | 104 | 3.53 / 545.56 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.23 | 286 | 719 | 4.24 / 546.28 | 2 | 2 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 30 | 15.16 | 486 | 221 | 0.22 / 537.89 | 2 | 2 |
2 | 7 | 2007.20 | 53 | 15.00 | 3149 | 2503 | 2.72 / 540.40 | 2 | 2 |
3 | 13 | 1021.12 | 18 | 15.02 | 1801 | 487 | 3.21 / 540.88 | 2 | 3 |
4 | 13 | 304.20 | 18 | 15.20 | 766 | 210 | 3.42 / 541.09 | 2 | 3 |
5 | 13 | 35.28 | 18 | 15.27 | 354 | 97 | 3.52 / 541.19 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.24 | 284 | 714 | 4.23 / 541.90 | 2 | 3 |
7 | 14 | -0.12 | 30 | 15.21 | 285 | 130 | 4.36 / 542.03 | 2 | 3 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 30 | 15.16 | 478 | 217 | 0.22 / 533.60 | 2 | 2 |
2 | 7 | 2005.84 | 53 | 15.00 | 3149 | 2503 | 2.72 / 536.10 | 2 | 2 |
3 | 13 | 1014.96 | 18 | 15.03 | 1789 | 484 | 3.20 / 536.59 | 2 | 3 |
4 | 13 | 418.72 | 18 | 15.18 | 936 | 256 | 3.46 / 536.84 | 2 | 4 |
5 | 13 | 51.88 | 18 | 15.27 | 385 | 106 | 3.57 / 536.95 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.23 | 287 | 721 | 4.29 / 537.67 | 2 | 3 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 30 | 15.16 | 479 | 218 | 0.22 / 529.41 | 2 | 2 |
2 | 7 | 2003.76 | 52 | 15.00 | 3148 | 2455 | 2.67 / 531.87 | 2 | 2 |
3 | 13 | 1022.28 | 18 | 15.01 | 1799 | 486 | 3.16 / 532.35 | 2 | 4 |
4 | 13 | 305.84 | 18 | 15.20 | 771 | 211 | 3.37 / 532.56 | 2 | 3 |
5 | 13 | 38.12 | 18 | 15.27 | 361 | 99 | 3.47 / 532.66 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.24 | 287 | 722 | 4.19 / 533.38 | 2 | 3 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 30 | 15.17 | 461 | 210 | 0.21 / 524.98 | 2 | 2 |
2 | 7 | 2011.00 | 53 | 15.00 | 3179 | 2527 | 2.74 / 527.51 | 2 | 2 |
3 | 13 | 1013.52 | 18 | 15.04 | 1788 | 484 | 3.22 / 527.99 | 2 | 3 |
4 | 13 | 427.20 | 18 | 15.16 | 949 | 259 | 3.48 / 528.25 | 2 | 4 |
5 | 13 | 23.32 | 18 | 15.27 | 336 | 92 | 3.57 / 528.34 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.24 | 286 | 719 | 4.29 / 529.06 | 2 | 3 |
7 | 14 | 0.04 | 30 | 15.22 | 286 | 131 | 4.42 / 529.19 | 2 | 4 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 30 | 15.16 | 457 | 208 | 0.21 / 520.73 | 2 | 2 |
2 | 7 | 2011.76 | 53 | 15.00 | 3170 | 2520 | 2.73 / 523.25 | 2 | 2 |
3 | 13 | 1026.76 | 18 | 15.03 | 1809 | 489 | 3.22 / 523.74 | 2 | 3 |
4 | 13 | 313.28 | 18 | 15.21 | 784 | 215 | 3.43 / 523.95 | 2 | 4 |
5 | 13 | 33.32 | 18 | 15.28 | 352 | 97 | 3.53 / 524.05 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.25 | 286 | 720 | 4.25 / 524.77 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.96 | 30 | 15.17 | 480 | 218 | 0.22 / 516.50 | 2 | 2 |
2 | 7 | 2004.52 | 53 | 15.00 | 3159 | 2511 | 2.73 / 519.01 | 2 | 2 |
3 | 13 | 1017.80 | 18 | 15.01 | 1798 | 486 | 3.22 / 519.50 | 2 | 3 |
4 | 13 | 309.36 | 18 | 15.20 | 777 | 213 | 3.43 / 519.71 | 2 | 4 |
5 | 13 | 33.08 | 18 | 15.27 | 353 | 97 | 3.53 / 519.81 | 2 | 3 |
6 | 8 | 0.28 | 165 | 15.23 | 285 | 716 | 4.24 / 520.52 | 2 | 4 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 30 | 15.19 | 474 | 216 | 0.22 / 512.22 | 2 | 2 |
2 | 7 | 2008.16 | 53 | 15.00 | 3154 | 2507 | 2.72 / 514.73 | 2 | 2 |
3 | 13 | 1018.84 | 18 | 15.02 | 1800 | 487 | 3.21 / 515.21 | 2 | 4 |
4 | 13 | 419.40 | 18 | 15.18 | 937 | 256 | 3.47 / 515.47 | 2 | 4 |
5 | 13 | 28.68 | 18 | 15.27 | 345 | 95 | 3.56 / 515.56 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.24 | 285 | 717 | 4.28 / 516.28 | 2 | 2 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 30 | 15.17 | 474 | 216 | 0.22 / 507.93 | 2 | 2 |
2 | 7 | 2006.52 | 53 | 15.02 | 3150 | 2508 | 2.72 / 510.44 | 2 | 2 |
3 | 13 | 1030.48 | 18 | 15.02 | 1815 | 491 | 3.21 / 510.93 | 2 | 3 |
4 | 13 | 434.64 | 18 | 15.17 | 960 | 262 | 3.48 / 511.19 | 2 | 4 |
5 | 13 | 26.52 | 18 | 15.27 | 345 | 95 | 3.57 / 511.28 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.24 | 286 | 719 | 4.29 / 512.00 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.92 | 30 | 15.17 | 486 | 221 | 0.22 / 503.70 | 2 | 2 |
2 | 7 | 2011.84 | 52 | 15.00 | 3181 | 2481 | 2.70 / 506.19 | 2 | 2 |
3 | 13 | 1026.44 | 18 | 15.03 | 1808 | 489 | 3.19 / 506.67 | 2 | 4 |
4 | 13 | 321.36 | 18 | 15.21 | 794 | 217 | 3.41 / 506.89 | 2 | 3 |
5 | 13 | 36.28 | 18 | 15.27 | 359 | 99 | 3.51 / 506.99 | 2 | 3 |
6 | 8 | -0.16 | 165 | 15.24 | 287 | 722 | 4.23 / 507.71 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 30 | 15.18 | 461 | 210 | 0.21 / 499.47 | 2 | 2 |
2 | 7 | 2007.32 | 53 | 15.02 | 3142 | 2501 | 2.71 / 501.97 | 2 | 2 |
3 | 13 | 1014.92 | 18 | 15.03 | 1791 | 485 | 3.20 / 502.45 | 2 | 4 |
4 | 13 | 307.20 | 18 | 15.22 | 778 | 213 | 3.41 / 502.67 | 2 | 3 |
5 | 13 | 29.96 | 18 | 15.28 | 346 | 95 | 3.50 / 502.76 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.25 | 287 | 722 | 4.23 / 503.48 | 2 | 4 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 30 | 15.18 | 481 | 219 | 0.22 / 495.15 | 2 | 2 |
2 | 7 | 2007.88 | 53 | 15.02 | 3177 | 2529 | 2.75 / 497.68 | 2 | 2 |
3 | 13 | 1027.00 | 18 | 15.04 | 1807 | 489 | 3.24 / 498.17 | 2 | 3 |
4 | 13 | 435.72 | 18 | 15.19 | 961 | 263 | 3.50 / 498.43 | 2 | 4 |
5 | 13 | 48.88 | 18 | 15.29 | 381 | 105 | 3.60 / 498.54 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.24 | 287 | 722 | 4.33 / 499.26 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 30 | 15.18 | 486 | 221 | 0.22 / 490.86 | 2 | 2 |
2 | 7 | 2003.96 | 53 | 15.02 | 3155 | 2512 | 2.73 / 493.37 | 2 | 2 |
3 | 13 | 1014.84 | 18 | 15.04 | 1798 | 487 | 3.22 / 493.86 | 2 | 4 |
4 | 13 | 432.28 | 18 | 15.18 | 951 | 260 | 3.48 / 494.12 | 2 | 4 |
5 | 13 | 26.00 | 18 | 15.30 | 339 | 93 | 3.57 / 494.21 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.25 | 285 | 717 | 4.29 / 494.93 | 2 | 5 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 30 | 15.18 | 472 | 215 | 0.21 / 486.57 | 2 | 2 |
2 | 7 | 2004.20 | 53 | 15.02 | 3149 | 2507 | 2.72 / 489.08 | 2 | 2 |
3 | 13 | 1022.28 | 18 | 15.04 | 1805 | 489 | 3.21 / 489.57 | 2 | 3 |
4 | 13 | 427.52 | 18 | 15.19 | 948 | 259 | 3.47 / 489.83 | 2 | 4 |
5 | 13 | 25.36 | 18 | 15.29 | 336 | 92 | 3.56 / 489.92 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.26 | 286 | 720 | 4.28 / 490.64 | 2 | 4 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.76 | 30 | 15.19 | 467 | 213 | 0.21 / 482.36 | 2 | 2 |
2 | 7 | 2010.00 | 53 | 15.02 | 3159 | 2515 | 2.73 / 484.88 | 2 | 2 |
3 | 13 | 1039.88 | 18 | 15.02 | 1826 | 494 | 3.22 / 485.37 | 2 | 3 |
4 | 13 | 440.96 | 18 | 15.18 | 964 | 263 | 3.48 / 485.64 | 2 | 5 |
5 | 8 | 0.20 | 165 | 15.26 | 287 | 723 | 4.21 / 486.36 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 30 | 15.17 | 477 | 217 | 0.22 / 478.01 | 2 | 2 |
2 | 7 | 2003.96 | 52 | 15.04 | 3146 | 2460 | 2.68 / 480.47 | 2 | 2 |
3 | 13 | 1025.52 | 18 | 15.03 | 1804 | 488 | 3.17 / 480.96 | 2 | 3 |
4 | 13 | 426.12 | 18 | 15.17 | 946 | 258 | 3.42 / 481.21 | 2 | 4 |
5 | 13 | 23.04 | 18 | 15.27 | 334 | 92 | 3.52 / 481.31 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.24 | 284 | 714 | 4.23 / 482.02 | 2 | 7 |
7 | 14 | -0.08 | 30 | 15.22 | 285 | 130 | 4.36 / 482.15 | 2 | 4 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.12 | 30 | 15.20 | 483 | 220 | 0.22 / 473.76 | 2 | 2 |
2 | 7 | 2012.00 | 53 | 15.02 | 3154 | 2511 | 2.73 / 476.27 | 2 | 2 |
3 | 13 | 1027.00 | 18 | 15.04 | 1807 | 489 | 3.22 / 476.76 | 2 | 3 |
4 | 13 | 330.88 | 18 | 15.21 | 810 | 222 | 3.44 / 476.98 | 2 | 3 |
5 | 13 | 33.72 | 18 | 15.29 | 348 | 96 | 3.54 / 477.07 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.24 | 285 | 717 | 4.25 / 477.79 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 30 | 15.18 | 484 | 220 | 0.22 / 469.60 | 2 | 2 |
2 | 7 | 2004.12 | 53 | 15.03 | 3176 | 2530 | 2.75 / 472.12 | 2 | 2 |
3 | 13 | 1011.36 | 18 | 15.05 | 1786 | 484 | 3.23 / 472.61 | 2 | 4 |
4 | 13 | 305.76 | 18 | 15.24 | 772 | 212 | 3.45 / 472.82 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.28 | 284 | 716 | 4.16 / 473.54 | 2 | 4 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 30 | 15.18 | 484 | 220 | 0.22 / 465.18 | 2 | 2 |
2 | 7 | 2005.72 | 53 | 15.02 | 3155 | 2512 | 2.73 / 467.69 | 2 | 2 |
3 | 13 | 1032.48 | 18 | 15.04 | 1820 | 493 | 3.22 / 468.18 | 2 | 4 |
4 | 13 | 426.40 | 18 | 15.19 | 946 | 259 | 3.48 / 468.44 | 2 | 4 |
5 | 13 | 24.28 | 18 | 15.28 | 333 | 92 | 3.57 / 468.53 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.24 | 283 | 712 | 4.29 / 469.24 | 2 | 3 |
7 | 14 | 0.04 | 30 | 15.22 | 284 | 130 | 4.42 / 469.37 | 2 | 4 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 30 | 15.19 | 465 | 212 | 0.21 / 461.04 | 2 | 2 |
2 | 7 | 2006.24 | 53 | 15.00 | 3154 | 2507 | 2.72 / 463.55 | 2 | 2 |
3 | 13 | 1018.28 | 18 | 15.02 | 1789 | 484 | 3.20 / 464.03 | 2 | 3 |
4 | 13 | 299.92 | 18 | 15.22 | 762 | 209 | 3.41 / 464.24 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.25 | 284 | 715 | 4.13 / 464.96 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 30 | 15.21 | 463 | 211 | 0.21 / 456.73 | 2 | 2 |
2 | 7 | 2006.80 | 53 | 15.01 | 3164 | 2517 | 2.73 / 459.24 | 2 | 2 |
3 | 13 | 1008.28 | 18 | 15.05 | 1785 | 484 | 3.21 / 459.73 | 2 | 3 |
4 | 13 | 426.28 | 18 | 15.18 | 944 | 258 | 3.47 / 459.98 | 2 | 3 |
5 | 8 | 0.24 | 165 | 15.27 | 285 | 718 | 4.19 / 460.70 | 2 | 3 |
6 | 14 | 0.24 | 30 | 15.24 | 285 | 130 | 4.32 / 460.83 | 2 | 2 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 30 | 15.20 | 458 | 209 | 0.21 / 452.55 | 2 | 2 |
2 | 7 | 2005.36 | 53 | 15.03 | 3156 | 2514 | 2.72 / 455.06 | 2 | 2 |
3 | 13 | 1003.44 | 18 | 15.04 | 1769 | 479 | 3.20 / 455.54 | 2 | 4 |
4 | 13 | 413.60 | 18 | 15.19 | 923 | 252 | 3.45 / 455.79 | 2 | 4 |
5 | 8 | -0.12 | 165 | 15.27 | 287 | 723 | 4.18 / 456.51 | 2 | 2 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 30 | 15.19 | 465 | 212 | 0.21 / 448.41 | 2 | 2 |
2 | 7 | 2010.96 | 53 | 15.02 | 3162 | 2517 | 2.73 / 450.92 | 2 | 2 |
3 | 13 | 1015.40 | 18 | 15.03 | 1789 | 484 | 3.21 / 451.41 | 2 | 4 |
4 | 13 | 301.64 | 18 | 15.22 | 762 | 209 | 3.42 / 451.62 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.26 | 286 | 720 | 4.14 / 452.34 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 30 | 15.21 | 486 | 222 | 0.22 / 444.14 | 2 | 2 |
2 | 7 | 2004.20 | 53 | 15.00 | 3153 | 2507 | 2.73 / 446.65 | 2 | 2 |
3 | 13 | 1017.40 | 18 | 15.03 | 1791 | 485 | 3.21 / 447.13 | 2 | 3 |
4 | 13 | 310.12 | 18 | 15.22 | 772 | 211 | 3.42 / 447.35 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.26 | 285 | 718 | 4.14 / 448.06 | 2 | 3 |
6 | 14 | 0.20 | 30 | 15.24 | 287 | 131 | 4.27 / 448.19 | 2 | 2 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 30 | 15.21 | 493 | 225 | 0.22 / 440.00 | 2 | 2 |
2 | 7 | 2005.04 | 52 | 15.03 | 3172 | 2479 | 2.70 / 442.48 | 2 | 2 |
3 | 13 | 1027.28 | 18 | 15.07 | 1806 | 490 | 3.19 / 442.97 | 2 | 4 |
4 | 13 | 325.08 | 18 | 15.22 | 794 | 218 | 3.41 / 443.19 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.28 | 290 | 731 | 4.14 / 443.92 | 2 | 4 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 30 | 15.21 | 483 | 220 | 0.22 / 435.84 | 2 | 2 |
2 | 7 | 2008.92 | 53 | 15.02 | 3154 | 2511 | 2.73 / 438.35 | 2 | 2 |
3 | 13 | 1022.84 | 18 | 15.04 | 1805 | 489 | 3.22 / 438.84 | 2 | 4 |
4 | 13 | 326.68 | 18 | 15.23 | 806 | 221 | 3.44 / 439.06 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.28 | 286 | 721 | 4.16 / 439.78 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 30 | 15.21 | 487 | 222 | 0.22 / 431.68 | 2 | 3 |
2 | 7 | 2004.16 | 53 | 15.01 | 3155 | 2510 | 2.73 / 434.19 | 2 | 2 |
3 | 13 | 1029.84 | 18 | 15.05 | 1812 | 491 | 3.22 / 434.68 | 2 | 3 |
4 | 13 | 315.56 | 18 | 15.23 | 786 | 215 | 3.44 / 434.90 | 2 | 3 |
5 | 8 | 0.48 | 165 | 15.27 | 286 | 721 | 4.16 / 435.62 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.60 | 30 | 15.22 | 485 | 221 | 0.22 / 427.38 | 2 | 2 |
2 | 7 | 2007.60 | 53 | 15.04 | 3174 | 2530 | 2.75 / 429.91 | 2 | 2 |
3 | 13 | 1014.56 | 18 | 15.06 | 1790 | 485 | 3.24 / 430.40 | 2 | 3 |
4 | 13 | 298.48 | 18 | 15.24 | 762 | 209 | 3.45 / 430.61 | 2 | 4 |
5 | 8 | -0.28 | 165 | 15.28 | 285 | 719 | 4.16 / 431.33 | 2 | 3 |
6 | 14 | -0.28 | 30 | 15.26 | 285 | 130 | 4.29 / 431.46 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 30 | 15.22 | 475 | 217 | 0.22 / 423.18 | 2 | 2 |
2 | 7 | 2006.12 | 53 | 15.05 | 3151 | 2513 | 2.73 / 425.70 | 2 | 2 |
3 | 13 | 1027.92 | 18 | 15.05 | 1805 | 489 | 3.22 / 426.19 | 2 | 3 |
4 | 13 | 443.88 | 18 | 15.21 | 972 | 266 | 3.49 / 426.45 | 2 | 4 |
5 | 8 | 0.28 | 165 | 15.29 | 282 | 711 | 4.20 / 427.16 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 30 | 15.20 | 480 | 219 | 0.22 / 419.12 | 2 | 2 |
2 | 7 | 2006.28 | 52 | 15.04 | 3165 | 2475 | 2.69 / 421.59 | 2 | 2 |
3 | 13 | 897.64 | 18 | 15.10 | 1624 | 441 | 3.14 / 422.03 | 2 | 4 |
4 | 13 | 337.40 | 18 | 15.24 | 815 | 224 | 3.36 / 422.26 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.29 | 281 | 709 | 4.07 / 422.97 | 2 | 4 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 30 | 15.21 | 467 | 213 | 0.21 / 414.86 | 2 | 2 |
2 | 7 | 2008.24 | 53 | 15.01 | 3153 | 2508 | 2.72 / 417.36 | 2 | 2 |
3 | 13 | 909.40 | 18 | 15.08 | 1643 | 446 | 3.17 / 417.81 | 2 | 4 |
4 | 13 | 479.12 | 18 | 15.19 | 1023 | 280 | 3.45 / 418.09 | 2 | 4 |
5 | 13 | 32.00 | 18 | 15.31 | 347 | 96 | 3.54 / 418.19 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.27 | 283 | 713 | 4.26 / 418.90 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 30 | 15.23 | 482 | 220 | 0.22 / 410.66 | 2 | 2 |
2 | 7 | 2003.32 | 53 | 15.02 | 3163 | 2518 | 2.74 / 413.17 | 2 | 2 |
3 | 13 | 1019.28 | 18 | 15.04 | 1786 | 484 | 3.22 / 413.66 | 2 | 4 |
4 | 13 | 433.08 | 18 | 15.20 | 955 | 261 | 3.48 / 413.92 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.28 | 287 | 724 | 4.21 / 414.64 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 30 | 15.21 | 472 | 215 | 0.22 / 406.52 | 2 | 2 |
2 | 7 | 2006.56 | 53 | 15.04 | 3149 | 2510 | 2.73 / 409.03 | 2 | 2 |
3 | 13 | 1011.76 | 18 | 15.06 | 1780 | 483 | 3.21 / 409.51 | 2 | 3 |
4 | 13 | 291.40 | 18 | 15.26 | 747 | 205 | 3.41 / 409.72 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.29 | 284 | 716 | 4.13 / 410.44 | 2 | 3 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 30 | 15.21 | 460 | 210 | 0.21 / 402.10 | 2 | 2 |
2 | 7 | 2006.16 | 53 | 15.04 | 3154 | 2514 | 2.72 / 404.61 | 2 | 2 |
3 | 13 | 1011.88 | 18 | 15.08 | 1786 | 485 | 3.21 / 405.10 | 2 | 4 |
4 | 13 | 425.04 | 18 | 15.23 | 946 | 259 | 3.47 / 405.35 | 2 | 3 |
5 | 13 | 51.40 | 18 | 15.33 | 379 | 105 | 3.57 / 405.46 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.29 | 284 | 716 | 4.29 / 406.18 | 2 | 7 |
7 | 14 | 0.12 | 30 | 15.26 | 285 | 130 | 4.42 / 406.31 | 2 | 4 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 29 | 15.22 | 481 | 212 | 0.21 / 397.87 | 2 | 2 |
2 | 7 | 2002.32 | 52 | 15.05 | 3156 | 2470 | 2.68 / 400.34 | 2 | 2 |
3 | 13 | 1005.32 | 18 | 15.07 | 1775 | 481 | 3.16 / 400.82 | 2 | 4 |
4 | 13 | 415.08 | 18 | 15.23 | 923 | 253 | 3.42 / 401.07 | 2 | 4 |
5 | 13 | 22.88 | 18 | 15.33 | 334 | 92 | 3.51 / 401.16 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.30 | 286 | 722 | 4.23 / 401.89 | 2 | 2 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 30 | 15.23 | 454 | 207 | 0.21 / 393.58 | 2 | 2 |
2 | 7 | 2005.12 | 53 | 15.04 | 3160 | 2519 | 2.73 / 396.10 | 2 | 2 |
3 | 13 | 1014.72 | 18 | 15.08 | 1793 | 487 | 3.21 / 396.58 | 2 | 3 |
4 | 13 | 419.44 | 18 | 15.22 | 935 | 256 | 3.47 / 396.84 | 2 | 4 |
5 | 13 | 49.36 | 18 | 15.31 | 377 | 104 | 3.57 / 396.94 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.28 | 283 | 713 | 4.29 / 397.66 | 2 | 3 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 30 | 15.22 | 475 | 217 | 0.22 / 389.46 | 2 | 2 |
2 | 7 | 2003.08 | 53 | 15.03 | 3144 | 2504 | 2.72 / 391.96 | 2 | 2 |
3 | 13 | 1016.08 | 18 | 15.07 | 1794 | 487 | 3.21 / 392.45 | 2 | 4 |
4 | 13 | 301.88 | 18 | 15.26 | 766 | 210 | 3.42 / 392.66 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.30 | 282 | 712 | 4.13 / 393.37 | 2 | 4 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 30 | 15.21 | 482 | 220 | 0.22 / 385.22 | 2 | 2 |
2 | 7 | 2005.68 | 53 | 15.06 | 3151 | 2515 | 2.74 / 387.74 | 2 | 2 |
3 | 13 | 1003.92 | 18 | 15.10 | 1775 | 482 | 3.22 / 388.22 | 2 | 3 |
4 | 13 | 300.84 | 18 | 15.26 | 764 | 210 | 3.43 / 388.43 | 2 | 3 |
5 | 13 | 35.08 | 18 | 15.33 | 352 | 97 | 3.52 / 388.53 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.29 | 282 | 711 | 4.24 / 389.24 | 2 | 3 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 30 | 15.23 | 473 | 216 | 0.22 / 380.84 | 2 | 2 |
2 | 7 | 2010.56 | 53 | 15.02 | 3161 | 2516 | 2.73 / 383.36 | 2 | 2 |
3 | 13 | 1037.44 | 18 | 15.05 | 1819 | 493 | 3.23 / 383.85 | 2 | 4 |
4 | 13 | 314.20 | 18 | 15.25 | 779 | 214 | 3.44 / 384.06 | 2 | 3 |
5 | 13 | 39.08 | 18 | 15.32 | 359 | 99 | 3.54 / 384.16 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.28 | 282 | 711 | 4.25 / 384.87 | 2 | 3 |
7 | 14 | -0.04 | 30 | 15.25 | 282 | 129 | 4.38 / 385.00 | 2 | 3 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 30 | 15.24 | 468 | 214 | 0.21 / 376.47 | 2 | 2 |
2 | 7 | 2006.00 | 53 | 15.06 | 3151 | 2515 | 2.73 / 378.99 | 2 | 2 |
3 | 13 | 1020.96 | 18 | 15.07 | 1794 | 487 | 3.22 / 379.47 | 2 | 4 |
4 | 13 | 298.52 | 18 | 15.29 | 759 | 209 | 3.42 / 379.68 | 2 | 3 |
5 | 13 | 33.44 | 18 | 15.33 | 348 | 96 | 3.52 / 379.78 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.30 | 284 | 717 | 4.24 / 380.49 | 2 | 5 |
7 | 14 | 0.08 | 30 | 15.28 | 284 | 130 | 4.37 / 380.62 | 2 | 3 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 30 | 15.23 | 481 | 220 | 0.22 / 372.22 | 2 | 2 |
2 | 7 | 2004.00 | 53 | 15.07 | 3158 | 2522 | 2.74 / 374.75 | 2 | 2 |
3 | 13 | 1016.96 | 18 | 15.09 | 1795 | 488 | 3.23 / 375.23 | 2 | 3 |
4 | 13 | 304.04 | 18 | 15.29 | 765 | 211 | 3.44 / 375.44 | 2 | 3 |
5 | 13 | 32.36 | 18 | 15.35 | 348 | 96 | 3.54 / 375.54 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.31 | 284 | 717 | 4.25 / 376.26 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 30 | 15.24 | 474 | 217 | 0.22 / 368.02 | 2 | 2 |
2 | 7 | 2005.76 | 52 | 15.07 | 3155 | 2472 | 2.69 / 370.49 | 2 | 2 |
3 | 13 | 1019.88 | 18 | 15.09 | 1800 | 489 | 3.18 / 370.98 | 2 | 3 |
4 | 13 | 300.68 | 18 | 15.28 | 763 | 210 | 3.39 / 371.19 | 2 | 3 |
5 | 13 | 36.00 | 18 | 15.34 | 352 | 97 | 3.49 / 371.29 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.30 | 283 | 714 | 4.20 / 372.00 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.16 | 30 | 15.23 | 481 | 220 | 0.22 / 363.78 | 2 | 2 |
2 | 7 | 2003.12 | 53 | 15.06 | 3134 | 2501 | 2.72 / 366.29 | 2 | 2 |
3 | 13 | 1028.16 | 18 | 15.08 | 1806 | 490 | 3.21 / 366.78 | 2 | 3 |
4 | 13 | 315.36 | 18 | 15.28 | 784 | 216 | 3.43 / 366.99 | 2 | 3 |
5 | 13 | 39.16 | 18 | 15.34 | 359 | 99 | 3.53 / 367.09 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.31 | 282 | 712 | 4.24 / 367.80 | 2 | 4 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 29 | 15.25 | 480 | 212 | 0.21 / 359.48 | 2 | 2 |
2 | 7 | 2004.16 | 53 | 15.07 | 3159 | 2523 | 2.74 / 362.00 | 2 | 2 |
3 | 13 | 1017.60 | 18 | 15.09 | 1792 | 487 | 3.22 / 362.49 | 2 | 4 |
4 | 13 | 415.20 | 18 | 15.25 | 930 | 255 | 3.48 / 362.74 | 2 | 4 |
5 | 13 | 46.52 | 18 | 15.35 | 373 | 103 | 3.58 / 362.85 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.32 | 284 | 718 | 4.30 / 363.57 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 29 | 15.26 | 474 | 210 | 0.21 / 355.29 | 2 | 2 |
2 | 7 | 2005.24 | 52 | 15.08 | 3142 | 2464 | 2.67 / 357.75 | 2 | 2 |
3 | 13 | 1017.08 | 18 | 15.10 | 1793 | 487 | 3.16 / 358.24 | 2 | 4 |
4 | 13 | 312.08 | 18 | 15.29 | 781 | 215 | 3.38 / 358.45 | 2 | 3 |
5 | 13 | 40.72 | 18 | 15.36 | 360 | 100 | 3.48 / 358.55 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.32 | 282 | 713 | 4.19 / 359.27 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 29 | 15.25 | 467 | 207 | 0.21 / 350.90 | 2 | 2 |
2 | 7 | 2007.64 | 53 | 15.07 | 3165 | 2528 | 2.73 / 353.43 | 2 | 2 |
3 | 13 | 1022.60 | 18 | 15.09 | 1795 | 488 | 3.22 / 353.92 | 2 | 3 |
4 | 13 | 303.12 | 18 | 15.29 | 769 | 212 | 3.43 / 354.13 | 2 | 3 |
5 | 13 | 38.28 | 18 | 15.36 | 359 | 99 | 3.53 / 354.23 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.32 | 285 | 720 | 4.25 / 354.95 | 2 | 4 |
7 | 14 | 0.12 | 30 | 15.29 | 285 | 131 | 4.38 / 355.08 | 2 | 3 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.84 | 29 | 15.25 | 486 | 215 | 0.21 / 346.48 | 2 | 2 |
2 | 7 | 2003.48 | 53 | 15.07 | 3152 | 2518 | 2.73 / 349.00 | 2 | 2 |
3 | 13 | 1011.44 | 18 | 15.11 | 1788 | 486 | 3.22 / 349.49 | 2 | 4 |
4 | 13 | 421.60 | 18 | 15.26 | 940 | 258 | 3.48 / 349.75 | 2 | 3 |
5 | 13 | 49.64 | 18 | 15.36 | 381 | 105 | 3.58 / 349.85 | 2 | 3 |
6 | 8 | -0.16 | 165 | 15.31 | 283 | 715 | 4.30 / 350.57 | 2 | 3 |
7 | 14 | -0.16 | 30 | 15.29 | 280 | 128 | 4.43 / 350.69 | 3 | 4 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 29 | 15.27 | 479 | 212 | 0.21 / 342.23 | 2 | 2 |
2 | 7 | 2004.12 | 52 | 15.07 | 3160 | 2476 | 2.69 / 344.71 | 2 | 2 |
3 | 13 | 1015.68 | 18 | 15.10 | 1797 | 488 | 3.18 / 345.20 | 2 | 3 |
4 | 13 | 424.56 | 18 | 15.25 | 945 | 259 | 3.44 / 345.46 | 2 | 4 |
5 | 13 | 29.56 | 18 | 15.36 | 344 | 95 | 3.53 / 345.55 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.32 | 283 | 715 | 4.25 / 346.27 | 2 | 3 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 29 | 15.27 | 474 | 210 | 0.21 / 338.03 | 2 | 3 |
2 | 7 | 2007.44 | 52 | 15.06 | 3160 | 2475 | 2.68 / 340.51 | 2 | 2 |
3 | 13 | 1032.64 | 18 | 15.09 | 1812 | 492 | 3.18 / 341.00 | 2 | 4 |
4 | 13 | 322.12 | 18 | 15.29 | 798 | 220 | 3.40 / 341.22 | 2 | 3 |
5 | 13 | 19.72 | 18 | 15.37 | 326 | 90 | 3.49 / 341.31 | 2 | 3 |
6 | 8 | -0.16 | 165 | 15.33 | 282 | 713 | 4.20 / 342.02 | 2 | 4 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 29 | 15.28 | 473 | 210 | 0.21 / 333.78 | 2 | 2 |
2 | 7 | 2008.40 | 53 | 15.07 | 3164 | 2527 | 2.74 / 336.31 | 2 | 2 |
3 | 13 | 1017.04 | 18 | 15.10 | 1795 | 488 | 3.22 / 336.80 | 2 | 4 |
4 | 13 | 305.56 | 18 | 15.31 | 773 | 213 | 3.44 / 337.01 | 2 | 4 |
5 | 13 | 18.92 | 18 | 15.38 | 330 | 91 | 3.53 / 337.10 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.35 | 285 | 722 | 4.25 / 337.82 | 2 | 3 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 29 | 15.28 | 474 | 210 | 0.21 / 329.49 | 2 | 2 |
2 | 7 | 2007.60 | 53 | 15.08 | 3165 | 2530 | 2.74 / 332.02 | 2 | 2 |
3 | 13 | 1011.00 | 18 | 15.12 | 1786 | 486 | 3.23 / 332.50 | 2 | 4 |
4 | 13 | 416.96 | 18 | 15.27 | 934 | 257 | 3.48 / 332.76 | 2 | 4 |
5 | 13 | 25.76 | 18 | 15.38 | 339 | 94 | 3.58 / 332.85 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.34 | 284 | 719 | 4.30 / 333.57 | 2 | 3 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 29 | 15.30 | 483 | 214 | 0.21 / 325.21 | 2 | 2 |
2 | 7 | 2004.32 | 53 | 15.09 | 3153 | 2522 | 2.74 / 327.73 | 2 | 2 |
3 | 13 | 1001.84 | 18 | 15.12 | 1762 | 480 | 3.22 / 328.21 | 2 | 3 |
4 | 13 | 410.92 | 18 | 15.28 | 923 | 254 | 3.47 / 328.47 | 2 | 4 |
5 | 13 | 24.64 | 18 | 15.38 | 333 | 92 | 3.56 / 328.56 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.35 | 283 | 717 | 4.28 / 329.28 | 2 | 4 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 29 | 15.30 | 462 | 205 | 0.20 / 320.93 | 2 | 2 |
2 | 7 | 2002.52 | 53 | 15.07 | 3146 | 2513 | 2.72 / 323.44 | 2 | 2 |
3 | 13 | 1011.12 | 18 | 15.12 | 1790 | 487 | 3.20 / 323.93 | 2 | 3 |
4 | 13 | 419.96 | 18 | 15.28 | 940 | 259 | 3.46 / 324.19 | 2 | 4 |
5 | 13 | 23.40 | 18 | 15.38 | 331 | 92 | 3.56 / 324.28 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.35 | 283 | 717 | 4.27 / 325.00 | 2 | 3 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 29 | 15.30 | 484 | 215 | 0.21 / 316.78 | 2 | 2 |
2 | 7 | 2004.32 | 53 | 15.08 | 3166 | 2530 | 2.75 / 319.31 | 2 | 2 |
3 | 13 | 1009.24 | 18 | 15.14 | 1785 | 486 | 3.23 / 319.80 | 2 | 3 |
4 | 13 | 276.84 | 18 | 15.35 | 730 | 202 | 3.43 / 320.00 | 2 | 4 |
5 | 8 | 0.20 | 165 | 15.37 | 287 | 728 | 4.16 / 320.73 | 2 | 3 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 29 | 15.32 | 481 | 214 | 0.21 / 312.51 | 2 | 2 |
2 | 7 | 2002.04 | 53 | 15.09 | 3146 | 2516 | 2.73 / 315.03 | 2 | 2 |
3 | 13 | 1001.40 | 18 | 15.15 | 1768 | 482 | 3.21 / 315.51 | 2 | 3 |
4 | 13 | 399.68 | 18 | 15.30 | 906 | 250 | 3.46 / 315.76 | 2 | 3 |
5 | 13 | 19.60 | 18 | 15.40 | 323 | 90 | 3.55 / 315.85 | 2 | 3 |
6 | 8 | 0.32 | 165 | 15.37 | 283 | 718 | 4.27 / 316.57 | 2 | 4 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.96 | 29 | 15.31 | 490 | 218 | 0.22 / 308.41 | 2 | 2 |
2 | 7 | 2008.20 | 52 | 15.09 | 3149 | 2471 | 2.69 / 310.88 | 2 | 3 |
3 | 13 | 1014.28 | 18 | 15.14 | 1789 | 488 | 3.18 / 311.37 | 2 | 3 |
4 | 13 | 295.44 | 18 | 15.33 | 755 | 208 | 3.38 / 311.58 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.38 | 282 | 716 | 4.10 / 312.30 | 2 | 2 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 29 | 15.31 | 490 | 218 | 0.22 / 304.19 | 2 | 2 |
2 | 7 | 2011.88 | 53 | 15.10 | 3156 | 2526 | 2.74 / 306.72 | 2 | 3 |
3 | 13 | 1019.84 | 18 | 15.14 | 1795 | 489 | 3.23 / 307.20 | 2 | 4 |
4 | 13 | 430.36 | 18 | 15.29 | 956 | 263 | 3.50 / 307.47 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.38 | 287 | 728 | 4.22 / 308.20 | 2 | 3 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 29 | 15.32 | 483 | 215 | 0.21 / 300.04 | 2 | 3 |
2 | 7 | 2002.84 | 53 | 15.07 | 3148 | 2514 | 2.73 / 302.55 | 2 | 2 |
3 | 13 | 1015.16 | 18 | 15.13 | 1788 | 487 | 3.22 / 303.04 | 2 | 4 |
4 | 13 | 298.92 | 18 | 15.34 | 757 | 209 | 3.42 / 303.25 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.37 | 285 | 723 | 4.15 / 303.97 | 2 | 3 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 29 | 15.32 | 486 | 216 | 0.22 / 295.76 | 2 | 3 |
2 | 7 | 2002.28 | 52 | 15.10 | 3143 | 2468 | 2.68 / 298.22 | 2 | 2 |
3 | 13 | 1008.08 | 18 | 15.14 | 1778 | 485 | 3.17 / 298.71 | 2 | 5 |
4 | 13 | 419.56 | 18 | 15.31 | 937 | 258 | 3.43 / 298.97 | 2 | 4 |
5 | 8 | 0.12 | 165 | 15.38 | 286 | 726 | 4.15 / 299.69 | 2 | 2 |
6 | 14 | 0.12 | 30 | 15.36 | 288 | 133 | 4.29 / 299.82 | 2 | 4 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 29 | 15.33 | 490 | 218 | 0.22 / 291.55 | 2 | 2 |
2 | 7 | 2006.68 | 53 | 15.09 | 3161 | 2528 | 2.75 / 294.07 | 2 | 2 |
3 | 13 | 1014.32 | 18 | 15.14 | 1785 | 486 | 3.23 / 294.56 | 2 | 4 |
4 | 13 | 414.88 | 18 | 15.31 | 932 | 257 | 3.49 / 294.82 | 2 | 4 |
5 | 8 | 0.08 | 165 | 15.38 | 285 | 723 | 4.21 / 295.54 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 29 | 15.33 | 488 | 217 | 0.22 / 287.40 | 2 | 2 |
2 | 7 | 2003.44 | 53 | 15.09 | 3148 | 2518 | 2.73 / 289.92 | 2 | 3 |
3 | 13 | 996.20 | 18 | 15.16 | 1767 | 482 | 3.22 / 290.40 | 2 | 5 |
4 | 13 | 279.32 | 18 | 15.35 | 730 | 202 | 3.42 / 290.60 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.39 | 286 | 726 | 4.14 / 291.33 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.24 | 29 | 15.34 | 489 | 218 | 0.22 / 283.26 | 2 | 3 |
2 | 7 | 2002.16 | 53 | 15.09 | 3147 | 2517 | 2.73 / 285.77 | 2 | 2 |
3 | 13 | 990.48 | 18 | 15.17 | 1757 | 480 | 3.21 / 286.25 | 2 | 4 |
4 | 13 | 273.40 | 18 | 15.37 | 728 | 201 | 3.42 / 286.46 | 2 | 4 |
5 | 8 | 0.32 | 165 | 15.41 | 286 | 727 | 4.14 / 287.18 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 29 | 15.34 | 466 | 207 | 0.21 / 279.11 | 2 | 3 |
2 | 7 | 2004.60 | 53 | 15.10 | 3156 | 2526 | 2.73 / 281.64 | 2 | 3 |
3 | 13 | 906.52 | 18 | 15.19 | 1641 | 449 | 3.18 / 282.08 | 2 | 4 |
4 | 13 | 334.64 | 18 | 15.33 | 818 | 226 | 3.41 / 282.31 | 2 | 3 |
5 | 8 | -0.12 | 165 | 15.40 | 287 | 729 | 4.14 / 283.04 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 29 | 15.34 | 466 | 207 | 0.21 / 275.00 | 2 | 2 |
2 | 7 | 2005.40 | 52 | 15.11 | 3161 | 2484 | 2.69 / 277.49 | 2 | 2 |
3 | 13 | 1006.68 | 18 | 15.17 | 1783 | 487 | 3.18 / 277.97 | 2 | 4 |
4 | 13 | 277.76 | 18 | 15.38 | 735 | 203 | 3.38 / 278.18 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.42 | 285 | 725 | 4.11 / 278.90 | 2 | 2 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 29 | 15.33 | 480 | 213 | 0.21 / 270.82 | 2 | 2 |
2 | 7 | 2004.08 | 53 | 15.10 | 3136 | 2510 | 2.72 / 273.33 | 2 | 2 |
3 | 13 | 1009.44 | 18 | 15.16 | 1776 | 485 | 3.21 / 273.82 | 2 | 3 |
4 | 13 | 410.72 | 18 | 15.33 | 925 | 255 | 3.46 / 274.07 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.41 | 285 | 725 | 4.19 / 274.80 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 29 | 15.32 | 487 | 216 | 0.22 / 266.51 | 2 | 2 |
2 | 7 | 2003.88 | 53 | 15.07 | 3138 | 2506 | 2.72 / 269.01 | 2 | 2 |
3 | 13 | 1002.88 | 18 | 15.16 | 1773 | 484 | 3.21 / 269.50 | 2 | 3 |
4 | 13 | 417.20 | 18 | 15.30 | 933 | 257 | 3.46 / 269.75 | 2 | 4 |
5 | 8 | -0.08 | 165 | 15.39 | 285 | 724 | 4.19 / 270.48 | 2 | 2 |
6 | 14 | -0.08 | 30 | 15.37 | 286 | 132 | 4.32 / 270.61 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 29 | 15.36 | 456 | 203 | 0.20 / 262.35 | 2 | 2 |
2 | 7 | 2007.44 | 53 | 15.10 | 3157 | 2527 | 2.73 / 264.88 | 2 | 2 |
3 | 13 | 1007.28 | 18 | 15.16 | 1776 | 485 | 3.21 / 265.36 | 2 | 4 |
4 | 13 | 284.36 | 18 | 15.37 | 737 | 204 | 3.42 / 265.57 | 2 | 4 |
5 | 8 | 0.28 | 165 | 15.40 | 284 | 722 | 4.14 / 266.29 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 29 | 15.33 | 489 | 217 | 0.22 / 257.96 | 2 | 2 |
2 | 7 | 2002.56 | 53 | 15.09 | 3133 | 2506 | 2.72 / 260.47 | 2 | 2 |
3 | 13 | 1004.44 | 18 | 15.14 | 1768 | 482 | 3.20 / 260.95 | 2 | 4 |
4 | 13 | 417.36 | 18 | 15.32 | 931 | 257 | 3.46 / 261.21 | 2 | 4 |
5 | 13 | 28.60 | 18 | 15.45 | 341 | 95 | 3.56 / 261.30 | 2 | 3 |
6 | 8 | 0.64 | 165 | 15.41 | 283 | 720 | 4.28 / 262.02 | 2 | 3 |
7 | 14 | 0.64 | 30 | 15.39 | 281 | 130 | 4.41 / 262.15 | 2 | 3 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 29 | 15.33 | 466 | 207 | 0.21 / 253.76 | 2 | 3 |
2 | 7 | 2006.44 | 53 | 15.09 | 3156 | 2524 | 2.73 / 256.29 | 2 | 2 |
3 | 13 | 1003.72 | 18 | 15.16 | 1769 | 483 | 3.21 / 256.77 | 2 | 4 |
4 | 13 | 414.04 | 18 | 15.33 | 927 | 256 | 3.47 / 257.02 | 2 | 3 |
5 | 8 | -0.20 | 165 | 15.41 | 283 | 720 | 4.19 / 257.74 | 2 | 4 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 29 | 15.34 | 467 | 208 | 0.21 / 249.51 | 2 | 3 |
2 | 7 | 2006.56 | 53 | 15.10 | 3153 | 2523 | 2.73 / 252.04 | 2 | 3 |
3 | 13 | 1008.68 | 18 | 15.16 | 1782 | 486 | 3.22 / 252.52 | 2 | 4 |
4 | 13 | 282.96 | 18 | 15.36 | 741 | 205 | 3.42 / 252.73 | 2 | 3 |
5 | 13 | 61.56 | 18 | 15.43 | 395 | 110 | 3.53 / 252.84 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.40 | 282 | 717 | 4.25 / 253.55 | 2 | 3 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 29 | 15.35 | 465 | 207 | 0.21 / 245.35 | 2 | 2 |
2 | 7 | 2003.60 | 53 | 15.09 | 3162 | 2529 | 2.74 / 247.88 | 2 | 3 |
3 | 13 | 1004.48 | 18 | 15.16 | 1775 | 484 | 3.22 / 248.37 | 2 | 4 |
4 | 13 | 283.80 | 18 | 15.37 | 745 | 206 | 3.43 / 248.57 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.41 | 288 | 732 | 4.16 / 249.31 | 2 | 3 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 29 | 15.36 | 461 | 205 | 0.21 / 241.26 | 2 | 2 |
2 | 7 | 2004.76 | 52 | 15.11 | 3147 | 2473 | 2.68 / 243.73 | 2 | 2 |
3 | 13 | 1017.24 | 18 | 15.17 | 1785 | 487 | 3.17 / 244.22 | 2 | 4 |
4 | 13 | 292.88 | 18 | 15.38 | 751 | 208 | 3.37 / 244.42 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.43 | 284 | 723 | 4.10 / 245.15 | 2 | 3 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 29 | 15.37 | 472 | 210 | 0.21 / 237.11 | 2 | 2 |
2 | 7 | 2010.96 | 53 | 15.10 | 3164 | 2532 | 2.74 / 239.64 | 2 | 2 |
3 | 13 | 1014.48 | 18 | 15.17 | 1787 | 488 | 3.23 / 240.13 | 2 | 4 |
4 | 13 | 278.68 | 18 | 15.37 | 732 | 203 | 3.43 / 240.33 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.43 | 284 | 723 | 4.16 / 241.05 | 2 | 3 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 29 | 15.36 | 475 | 212 | 0.21 / 232.82 | 2 | 2 |
2 | 7 | 2005.88 | 53 | 15.11 | 3158 | 2529 | 2.74 / 235.35 | 2 | 2 |
3 | 13 | 1006.40 | 18 | 15.17 | 1778 | 486 | 3.23 / 235.84 | 2 | 3 |
4 | 13 | 286.88 | 18 | 15.39 | 744 | 206 | 3.43 / 236.04 | 2 | 3 |
5 | 8 | 0.68 | 165 | 15.43 | 284 | 723 | 4.16 / 236.76 | 2 | 2 |
6 | 14 | 0.68 | 30 | 15.40 | 283 | 131 | 4.29 / 236.90 | 3 | 4 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 29 | 15.37 | 462 | 206 | 0.21 / 228.65 | 2 | 2 |
2 | 7 | 2003.88 | 53 | 15.11 | 3152 | 2524 | 2.73 / 231.17 | 2 | 2 |
3 | 13 | 981.56 | 18 | 15.18 | 1740 | 475 | 3.21 / 231.65 | 2 | 5 |
4 | 13 | 371.04 | 18 | 15.37 | 866 | 240 | 3.45 / 231.89 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.44 | 284 | 724 | 4.17 / 232.61 | 2 | 2 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.08 | 29 | 15.38 | 486 | 217 | 0.22 / 224.41 | 2 | 2 |
2 | 7 | 2008.68 | 52 | 15.10 | 3159 | 2480 | 2.70 / 226.89 | 2 | 3 |
3 | 13 | 1012.08 | 18 | 15.19 | 1778 | 486 | 3.18 / 227.38 | 2 | 3 |
4 | 13 | 412.44 | 18 | 15.35 | 926 | 256 | 3.44 / 227.63 | 2 | 4 |
5 | 13 | 23.60 | 18 | 15.47 | 329 | 92 | 3.53 / 227.72 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.43 | 282 | 718 | 4.25 / 228.44 | 2 | 3 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.00 | 29 | 15.36 | 475 | 212 | 0.21 / 220.27 | 2 | 2 |
2 | 7 | 2002.16 | 53 | 15.11 | 3147 | 2520 | 2.73 / 222.79 | 2 | 2 |
3 | 13 | 993.48 | 18 | 15.19 | 1757 | 480 | 3.21 / 223.27 | 2 | 3 |
4 | 13 | 269.96 | 18 | 15.40 | 717 | 199 | 3.41 / 223.47 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.44 | 284 | 724 | 4.13 / 224.19 | 2 | 3 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 29 | 15.38 | 475 | 212 | 0.21 / 216.04 | 2 | 2 |
2 | 7 | 2002.64 | 53 | 15.13 | 3149 | 2525 | 2.74 / 218.57 | 2 | 2 |
3 | 13 | 988.76 | 18 | 15.19 | 1750 | 478 | 3.22 / 219.05 | 2 | 4 |
4 | 13 | 273.00 | 18 | 15.40 | 726 | 201 | 3.42 / 219.25 | 2 | 3 |
5 | 13 | 25.96 | 18 | 15.47 | 337 | 94 | 3.51 / 219.34 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.43 | 281 | 715 | 4.23 / 220.06 | 2 | 3 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 29 | 15.36 | 457 | 204 | 0.20 / 211.82 | 2 | 2 |
2 | 7 | 2003.68 | 53 | 15.11 | 3148 | 2521 | 2.72 / 214.34 | 2 | 2 |
3 | 13 | 996.92 | 18 | 15.19 | 1766 | 483 | 3.21 / 214.82 | 2 | 4 |
4 | 13 | 260.28 | 18 | 15.41 | 703 | 195 | 3.40 / 215.02 | 2 | 3 |
5 | 13 | 21.92 | 18 | 15.47 | 328 | 91 | 3.49 / 215.11 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.43 | 283 | 721 | 4.21 / 215.83 | 2 | 2 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 29 | 15.37 | 455 | 203 | 0.20 / 207.66 | 2 | 2 |
2 | 7 | 2004.00 | 52 | 15.11 | 3144 | 2470 | 2.67 / 210.13 | 2 | 3 |
3 | 13 | 1000.52 | 18 | 15.19 | 1766 | 483 | 3.16 / 210.61 | 2 | 4 |
4 | 13 | 264.40 | 18 | 15.42 | 713 | 198 | 3.35 / 210.81 | 2 | 3 |
5 | 13 | 22.64 | 18 | 15.48 | 332 | 93 | 3.45 / 210.90 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.44 | 282 | 718 | 4.16 / 211.62 | 2 | 3 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 29 | 15.37 | 479 | 214 | 0.21 / 203.44 | 2 | 2 |
2 | 7 | 2008.56 | 53 | 15.11 | 3146 | 2519 | 2.73 / 205.96 | 2 | 2 |
3 | 13 | 1002.20 | 18 | 15.20 | 1769 | 484 | 3.22 / 206.44 | 2 | 3 |
4 | 13 | 278.92 | 18 | 15.41 | 728 | 202 | 3.42 / 206.64 | 2 | 3 |
5 | 13 | 29.04 | 18 | 15.47 | 340 | 95 | 3.51 / 206.74 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.43 | 281 | 715 | 4.23 / 207.45 | 2 | 4 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 29 | 15.39 | 481 | 215 | 0.21 / 199.19 | 2 | 3 |
2 | 7 | 2006.84 | 53 | 15.12 | 3159 | 2531 | 2.75 / 201.72 | 2 | 3 |
3 | 13 | 999.68 | 18 | 15.20 | 1761 | 482 | 3.23 / 202.20 | 2 | 3 |
4 | 13 | 278.40 | 18 | 15.41 | 732 | 203 | 3.43 / 202.40 | 2 | 4 |
5 | 13 | 28.72 | 18 | 15.48 | 342 | 95 | 3.53 / 202.50 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.45 | 284 | 724 | 4.25 / 203.22 | 2 | 4 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 29 | 15.39 | 473 | 211 | 0.21 / 194.95 | 2 | 2 |
2 | 7 | 2005.84 | 53 | 15.13 | 3155 | 2530 | 2.74 / 197.48 | 2 | 2 |
3 | 13 | 993.72 | 18 | 15.21 | 1762 | 482 | 3.22 / 197.96 | 2 | 3 |
4 | 13 | 260.44 | 18 | 15.42 | 706 | 196 | 3.42 / 198.15 | 2 | 3 |
5 | 13 | 27.80 | 18 | 15.48 | 339 | 94 | 3.51 / 198.25 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.45 | 284 | 724 | 4.24 / 198.97 | 2 | 3 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 29 | 15.40 | 477 | 213 | 0.21 / 190.65 | 2 | 2 |
2 | 7 | 2004.08 | 53 | 15.13 | 3157 | 2532 | 2.74 / 193.19 | 2 | 2 |
3 | 13 | 1011.32 | 18 | 15.22 | 1781 | 488 | 3.23 / 193.67 | 2 | 3 |
4 | 13 | 404.80 | 18 | 15.38 | 918 | 254 | 3.49 / 193.93 | 2 | 4 |
5 | 13 | 22.52 | 18 | 15.49 | 329 | 92 | 3.58 / 194.02 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.45 | 281 | 716 | 4.29 / 194.74 | 2 | 3 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 28 | 15.41 | 476 | 205 | 0.21 / 186.42 | 2 | 3 |
2 | 7 | 2004.00 | 53 | 15.15 | 3148 | 2528 | 2.73 / 188.94 | 2 | 2 |
3 | 13 | 998.28 | 18 | 15.22 | 1769 | 485 | 3.22 / 189.43 | 2 | 4 |
4 | 13 | 261.08 | 18 | 15.44 | 706 | 196 | 3.41 / 189.62 | 2 | 3 |
5 | 13 | 25.76 | 18 | 15.49 | 337 | 94 | 3.51 / 189.72 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.46 | 283 | 722 | 4.23 / 190.44 | 2 | 3 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 28 | 15.39 | 487 | 210 | 0.21 / 182.18 | 2 | 3 |
2 | 7 | 2003.08 | 53 | 15.15 | 3157 | 2535 | 2.74 / 184.72 | 2 | 3 |
3 | 13 | 1004.12 | 18 | 15.23 | 1770 | 485 | 3.23 / 185.20 | 2 | 3 |
4 | 13 | 264.12 | 18 | 15.44 | 710 | 197 | 3.43 / 185.40 | 2 | 3 |
5 | 13 | 24.44 | 18 | 15.50 | 333 | 93 | 3.52 / 185.49 | 2 | 2 |
6 | 8 | -0.08 | 165 | 15.47 | 282 | 720 | 4.24 / 186.21 | 2 | 3 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 28 | 15.41 | 481 | 208 | 0.21 / 177.93 | 2 | 3 |
2 | 7 | 2003.84 | 53 | 15.13 | 3154 | 2529 | 2.74 / 180.46 | 2 | 3 |
3 | 13 | 1003.36 | 18 | 15.23 | 1778 | 487 | 3.22 / 180.95 | 2 | 4 |
4 | 13 | 272.04 | 18 | 15.44 | 723 | 201 | 3.43 / 181.15 | 2 | 3 |
5 | 13 | 24.80 | 18 | 15.49 | 336 | 94 | 3.52 / 181.24 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.46 | 286 | 730 | 4.25 / 181.97 | 2 | 3 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 28 | 15.42 | 476 | 206 | 0.21 / 173.67 | 2 | 3 |
2 | 7 | 2004.40 | 53 | 15.15 | 3165 | 2541 | 2.75 / 176.22 | 2 | 2 |
3 | 13 | 998.72 | 18 | 15.23 | 1767 | 484 | 3.23 / 176.70 | 2 | 3 |
4 | 13 | 271.92 | 18 | 15.44 | 726 | 202 | 3.43 / 176.90 | 2 | 3 |
5 | 13 | 22.64 | 18 | 15.51 | 330 | 92 | 3.53 / 176.99 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.48 | 285 | 728 | 4.25 / 177.72 | 2 | 3 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 28 | 15.42 | 485 | 209 | 0.21 / 169.53 | 2 | 2 |
2 | 7 | 2002.68 | 53 | 15.14 | 3153 | 2530 | 2.74 / 172.06 | 2 | 3 |
3 | 13 | 995.48 | 18 | 15.24 | 1761 | 483 | 3.22 / 172.54 | 2 | 3 |
4 | 13 | 270.92 | 18 | 15.44 | 724 | 201 | 3.42 / 172.75 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.49 | 283 | 723 | 4.15 / 173.47 | 2 | 2 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.24 | 28 | 15.41 | 488 | 211 | 0.21 / 165.45 | 2 | 2 |
2 | 7 | 2002.44 | 52 | 15.16 | 3150 | 2483 | 2.69 / 167.94 | 2 | 3 |
3 | 13 | 881.96 | 18 | 15.28 | 1608 | 442 | 3.14 / 168.38 | 2 | 4 |
4 | 13 | 304.80 | 18 | 15.45 | 770 | 214 | 3.35 / 168.59 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.49 | 285 | 728 | 4.08 / 169.32 | 2 | 3 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 28 | 15.43 | 486 | 210 | 0.21 / 161.35 | 2 | 2 |
2 | 7 | 2004.04 | 52 | 15.13 | 3147 | 2476 | 2.69 / 163.82 | 2 | 3 |
3 | 13 | 1001.92 | 18 | 15.23 | 1774 | 486 | 3.17 / 164.31 | 2 | 4 |
4 | 13 | 273.12 | 18 | 15.44 | 728 | 202 | 3.37 / 164.51 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.47 | 286 | 730 | 4.10 / 165.24 | 2 | 2 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 28 | 15.44 | 480 | 208 | 0.21 / 157.20 | 2 | 2 |
2 | 7 | 2005.04 | 53 | 15.16 | 3154 | 2534 | 2.74 / 159.74 | 2 | 3 |
3 | 13 | 982.04 | 18 | 15.26 | 1750 | 481 | 3.22 / 160.22 | 2 | 4 |
4 | 13 | 247.84 | 18 | 15.47 | 688 | 192 | 3.41 / 160.41 | 2 | 3 |
5 | 8 | -0.16 | 165 | 15.50 | 286 | 731 | 4.15 / 161.14 | 2 | 2 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 28 | 15.42 | 485 | 209 | 0.21 / 153.05 | 2 | 2 |
2 | 7 | 2002.76 | 53 | 15.16 | 3148 | 2529 | 2.74 / 155.58 | 2 | 2 |
3 | 13 | 993.80 | 18 | 15.25 | 1760 | 483 | 3.22 / 156.06 | 2 | 5 |
4 | 13 | 267.76 | 18 | 15.46 | 723 | 201 | 3.42 / 156.26 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.50 | 287 | 734 | 4.16 / 156.99 | 2 | 3 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 28 | 15.44 | 462 | 200 | 0.20 / 148.74 | 2 | 3 |
2 | 7 | 2003.72 | 53 | 15.15 | 3158 | 2536 | 2.74 / 151.28 | 2 | 3 |
3 | 13 | 1011.52 | 18 | 15.24 | 1791 | 491 | 3.23 / 151.77 | 2 | 5 |
4 | 13 | 269.00 | 18 | 15.46 | 721 | 201 | 3.43 / 151.97 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.49 | 287 | 734 | 4.16 / 152.70 | 2 | 5 |
6 | 14 | 0.16 | 30 | 15.48 | 286 | 133 | 4.29 / 152.84 | 2 | 3 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 28 | 15.43 | 489 | 211 | 0.21 / 144.45 | 2 | 2 |
2 | 7 | 2004.12 | 53 | 15.17 | 3148 | 2531 | 2.74 / 146.98 | 2 | 3 |
3 | 13 | 1009.80 | 18 | 15.25 | 1783 | 489 | 3.23 / 147.47 | 2 | 4 |
4 | 13 | 267.92 | 18 | 15.46 | 721 | 201 | 3.43 / 147.67 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.50 | 287 | 734 | 4.17 / 148.41 | 2 | 2 |
6 | 14 | 0.28 | 30 | 15.49 | 288 | 134 | 4.30 / 148.54 | 2 | 2 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 28 | 15.45 | 485 | 210 | 0.21 / 140.28 | 2 | 3 |
2 | 7 | 2007.60 | 53 | 15.15 | 3169 | 2545 | 2.75 / 142.82 | 2 | 3 |
3 | 13 | 1007.56 | 18 | 15.24 | 1778 | 488 | 3.24 / 143.31 | 2 | 3 |
4 | 13 | 254.92 | 18 | 15.46 | 701 | 195 | 3.44 / 143.51 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.49 | 288 | 736 | 4.17 / 144.24 | 2 | 3 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 28 | 15.45 | 495 | 214 | 0.21 / 136.20 | 2 | 2 |
2 | 7 | 2004.00 | 53 | 15.16 | 3158 | 2537 | 2.75 / 138.73 | 2 | 3 |
3 | 13 | 880.04 | 18 | 15.31 | 1600 | 441 | 3.19 / 139.17 | 2 | 4 |
4 | 13 | 186.36 | 18 | 15.49 | 597 | 166 | 3.36 / 139.34 | 2 | 3 |
5 | 8 | -0.16 | 165 | 15.50 | 285 | 729 | 4.09 / 140.07 | 2 | 3 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 28 | 15.45 | 491 | 212 | 0.21 / 131.98 | 2 | 2 |
2 | 7 | 2002.44 | 53 | 15.18 | 3158 | 2541 | 2.75 / 134.53 | 2 | 2 |
3 | 13 | 982.16 | 18 | 15.29 | 1750 | 482 | 3.23 / 135.01 | 2 | 5 |
4 | 13 | 370.24 | 18 | 15.44 | 872 | 242 | 3.48 / 135.25 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.52 | 286 | 732 | 4.21 / 135.98 | 2 | 3 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 28 | 15.45 | 485 | 210 | 0.21 / 127.84 | 2 | 2 |
2 | 7 | 2004.80 | 53 | 15.17 | 3145 | 2529 | 2.74 / 130.37 | 2 | 2 |
3 | 13 | 992.64 | 18 | 15.27 | 1750 | 481 | 3.22 / 130.85 | 2 | 3 |
4 | 13 | 248.56 | 18 | 15.48 | 685 | 191 | 3.41 / 131.04 | 2 | 3 |
5 | 8 | 0.24 | 165 | 15.51 | 285 | 729 | 4.14 / 131.77 | 2 | 2 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 28 | 15.45 | 473 | 205 | 0.20 / 123.70 | 2 | 2 |
2 | 7 | 2002.60 | 53 | 15.18 | 3152 | 2536 | 2.74 / 126.24 | 2 | 2 |
3 | 13 | 974.28 | 18 | 15.28 | 1732 | 476 | 3.22 / 126.72 | 2 | 3 |
4 | 13 | 233.80 | 18 | 15.49 | 666 | 186 | 3.40 / 126.90 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.52 | 285 | 730 | 4.13 / 127.63 | 2 | 3 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 28 | 15.45 | 487 | 211 | 0.21 / 119.55 | 2 | 2 |
2 | 7 | 2006.20 | 53 | 15.17 | 3153 | 2535 | 2.75 / 122.09 | 2 | 2 |
3 | 13 | 990.68 | 18 | 15.28 | 1759 | 484 | 3.23 / 122.57 | 2 | 3 |
4 | 13 | 259.44 | 18 | 15.48 | 708 | 197 | 3.43 / 122.77 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.52 | 286 | 732 | 4.16 / 123.50 | 2 | 3 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 28 | 15.44 | 480 | 208 | 0.21 / 115.45 | 2 | 2 |
2 | 7 | 2004.48 | 53 | 15.16 | 3144 | 2526 | 2.73 / 117.97 | 2 | 2 |
3 | 13 | 868.92 | 18 | 15.30 | 1578 | 435 | 3.17 / 118.41 | 2 | 3 |
4 | 13 | 288.12 | 18 | 15.47 | 744 | 207 | 3.38 / 118.61 | 2 | 3 |
5 | 8 | -0.24 | 165 | 15.52 | 284 | 727 | 4.10 / 119.34 | 2 | 2 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 28 | 15.46 | 495 | 214 | 0.21 / 111.34 | 2 | 2 |
2 | 7 | 2007.36 | 53 | 15.16 | 3146 | 2528 | 2.74 / 113.86 | 2 | 2 |
3 | 13 | 1002.00 | 18 | 15.27 | 1770 | 487 | 3.23 / 114.35 | 2 | 3 |
4 | 13 | 160.08 | 18 | 15.50 | 557 | 155 | 3.38 / 114.51 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.50 | 286 | 731 | 4.12 / 115.24 | 2 | 3 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 28 | 15.44 | 479 | 207 | 0.21 / 107.24 | 2 | 2 |
2 | 7 | 2003.44 | 52 | 15.17 | 3136 | 2474 | 2.68 / 109.71 | 2 | 2 |
3 | 13 | 995.32 | 18 | 15.28 | 1763 | 485 | 3.17 / 110.20 | 2 | 3 |
4 | 13 | 251.60 | 18 | 15.49 | 689 | 192 | 3.36 / 110.39 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.53 | 286 | 733 | 4.09 / 111.12 | 2 | 2 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 28 | 15.44 | 491 | 212 | 0.21 / 103.09 | 2 | 2 |
2 | 7 | 2004.08 | 53 | 15.18 | 3142 | 2528 | 2.74 / 105.62 | 2 | 2 |
3 | 13 | 998.36 | 18 | 15.26 | 1764 | 485 | 3.22 / 106.11 | 2 | 3 |
4 | 13 | 260.08 | 18 | 15.48 | 705 | 196 | 3.42 / 106.30 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.51 | 285 | 729 | 4.15 / 107.03 | 2 | 3 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.88 | 28 | 15.46 | 480 | 208 | 0.21 / 98.95 | 2 | 2 |
2 | 7 | 2002.56 | 53 | 15.18 | 3149 | 2533 | 2.74 / 101.49 | 2 | 2 |
3 | 13 | 980.56 | 18 | 15.26 | 1733 | 476 | 3.22 / 101.96 | 2 | 3 |
4 | 13 | 240.40 | 18 | 15.47 | 676 | 188 | 3.41 / 102.15 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.50 | 286 | 731 | 4.14 / 102.88 | 2 | 3 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 28 | 15.47 | 456 | 198 | 0.20 / 94.89 | 2 | 2 |
2 | 7 | 2007.08 | 53 | 15.17 | 3153 | 2535 | 2.73 / 97.43 | 2 | 2 |
3 | 13 | 861.68 | 18 | 15.31 | 1569 | 432 | 3.16 / 97.86 | 2 | 3 |
4 | 13 | 164.12 | 18 | 15.51 | 563 | 157 | 3.32 / 98.02 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.52 | 284 | 727 | 4.05 / 98.74 | 2 | 3 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 28 | 15.46 | 486 | 210 | 0.21 / 90.82 | 2 | 2 |
2 | 7 | 2007.68 | 53 | 15.19 | 3162 | 2546 | 2.76 / 93.36 | 2 | 2 |
3 | 13 | 872.04 | 18 | 15.33 | 1582 | 437 | 3.19 / 93.80 | 2 | 3 |
4 | 13 | 183.56 | 18 | 15.51 | 594 | 166 | 3.36 / 93.97 | 2 | 3 |
5 | 8 | 0.00 | 165 | 15.52 | 285 | 730 | 4.09 / 94.70 | 2 | 3 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 28 | 15.47 | 459 | 199 | 0.20 / 86.67 | 2 | 2 |
2 | 7 | 2005.56 | 53 | 15.18 | 3138 | 2525 | 2.72 / 89.20 | 2 | 2 |
3 | 13 | 990.76 | 18 | 15.29 | 1754 | 483 | 3.21 / 89.68 | 2 | 3 |
4 | 13 | 257.44 | 18 | 15.50 | 702 | 196 | 3.40 / 89.87 | 2 | 3 |
5 | 8 | -0.08 | 165 | 15.53 | 286 | 733 | 4.13 / 90.61 | 2 | 3 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 28 | 15.46 | 486 | 210 | 0.21 / 82.53 | 2 | 2 |
2 | 7 | 2006.92 | 53 | 15.21 | 3145 | 2535 | 2.75 / 85.07 | 2 | 2 |
3 | 13 | 985.40 | 18 | 15.31 | 1751 | 483 | 3.23 / 85.55 | 2 | 3 |
4 | 13 | 240.80 | 18 | 15.52 | 680 | 190 | 3.42 / 85.74 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.54 | 285 | 731 | 4.15 / 86.47 | 2 | 2 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.92 | 28 | 15.46 | 486 | 210 | 0.21 / 78.40 | 2 | 2 |
2 | 7 | 2006.60 | 53 | 15.20 | 3159 | 2545 | 2.76 / 80.95 | 2 | 2 |
3 | 13 | 867.16 | 18 | 15.32 | 1573 | 434 | 3.19 / 81.38 | 2 | 3 |
4 | 13 | 294.04 | 18 | 15.48 | 754 | 210 | 3.40 / 81.59 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.54 | 285 | 731 | 4.13 / 82.32 | 2 | 2 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.60 | 28 | 15.47 | 484 | 210 | 0.21 / 74.25 | 2 | 2 |
2 | 7 | 2004.68 | 53 | 15.22 | 3149 | 2540 | 2.75 / 76.79 | 2 | 2 |
3 | 13 | 987.24 | 18 | 15.30 | 1748 | 481 | 3.23 / 77.27 | 2 | 2 |
4 | 13 | 251.84 | 18 | 15.50 | 694 | 194 | 3.42 / 77.47 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.54 | 283 | 726 | 4.15 / 78.19 | 2 | 2 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 28 | 15.48 | 457 | 198 | 0.20 / 69.79 | 2 | 2 |
2 | 7 | 2007.56 | 53 | 15.22 | 3133 | 2527 | 2.73 / 72.32 | 2 | 2 |
3 | 13 | 982.52 | 18 | 15.32 | 1737 | 479 | 3.20 / 72.80 | 2 | 2 |
4 | 13 | 241.28 | 18 | 15.51 | 678 | 189 | 3.39 / 72.99 | 2 | 2 |
5 | 8 | -0.16 | 165 | 15.54 | 284 | 728 | 4.12 / 73.71 | 2 | 2 |
6 | 14 | -0.16 | 75 | 15.51 | 282 | 328 | 4.45 / 74.04 | 2 | 3 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 28 | 15.49 | 479 | 208 | 0.21 / 65.59 | 2 | 2 |
2 | 7 | 2006.40 | 53 | 15.22 | 3154 | 2544 | 2.75 / 68.14 | 2 | 2 |
3 | 13 | 980.12 | 18 | 15.31 | 1742 | 480 | 3.23 / 68.62 | 2 | 2 |
4 | 13 | 382.80 | 18 | 15.48 | 885 | 247 | 3.48 / 68.86 | 2 | 2 |
5 | 8 | 0.08 | 165 | 15.54 | 284 | 728 | 4.21 / 69.59 | 2 | 2 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 28 | 15.48 | 470 | 204 | 0.20 / 61.51 | 2 | 2 |
2 | 7 | 2008.04 | 53 | 15.21 | 3155 | 2543 | 2.75 / 64.05 | 2 | 2 |
3 | 13 | 885.68 | 18 | 15.33 | 1599 | 441 | 3.19 / 64.49 | 2 | 2 |
4 | 13 | 187.60 | 18 | 15.53 | 597 | 167 | 3.36 / 64.66 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.55 | 284 | 729 | 4.08 / 65.39 | 2 | 2 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 28 | 15.47 | 460 | 199 | 0.20 / 57.41 | 2 | 2 |
2 | 7 | 2004.00 | 52 | 15.22 | 3144 | 2488 | 2.69 / 59.90 | 2 | 2 |
3 | 13 | 1000.32 | 18 | 15.32 | 1763 | 486 | 3.17 / 60.38 | 2 | 2 |
4 | 13 | 255.44 | 18 | 15.51 | 698 | 195 | 3.37 / 60.58 | 2 | 3 |
5 | 8 | -0.20 | 165 | 15.54 | 282 | 723 | 4.09 / 61.30 | 2 | 2 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 28 | 15.47 | 454 | 197 | 0.20 / 53.29 | 2 | 2 |
2 | 7 | 2006.80 | 53 | 15.22 | 3160 | 2549 | 2.75 / 55.84 | 2 | 2 |
3 | 13 | 872.08 | 18 | 15.35 | 1590 | 439 | 3.19 / 56.27 | 2 | 2 |
4 | 13 | 279.56 | 18 | 15.51 | 734 | 205 | 3.39 / 56.48 | 2 | 2 |
5 | 8 | 0.20 | 165 | 15.55 | 285 | 731 | 4.12 / 57.21 | 2 | 2 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 28 | 15.47 | 486 | 211 | 0.21 / 49.08 | 2 | 2 |
2 | 7 | 2002.12 | 53 | 15.21 | 3126 | 2520 | 2.73 / 51.60 | 2 | 2 |
3 | 13 | 983.48 | 18 | 15.31 | 1740 | 480 | 3.21 / 52.08 | 2 | 2 |
4 | 13 | 228.32 | 18 | 15.51 | 661 | 185 | 3.39 / 52.27 | 2 | 2 |
5 | 13 | 21.60 | 18 | 15.58 | 329 | 92 | 3.49 / 52.36 | 2 | 2 |
6 | 8 | 0.28 | 165 | 15.54 | 285 | 731 | 4.22 / 53.09 | 2 | 2 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 28 | 15.49 | 466 | 202 | 0.20 / 44.83 | 2 | 2 |
2 | 7 | 2005.52 | 52 | 15.21 | 3159 | 2499 | 2.70 / 47.33 | 2 | 2 |
3 | 13 | 978.48 | 18 | 15.31 | 1735 | 478 | 3.18 / 47.81 | 2 | 2 |
4 | 13 | 377.72 | 18 | 15.47 | 879 | 245 | 3.42 / 48.05 | 2 | 2 |
5 | 13 | 17.84 | 18 | 15.57 | 323 | 91 | 3.51 / 48.14 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.54 | 285 | 731 | 4.24 / 48.87 | 2 | 3 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 28 | 15.48 | 479 | 208 | 0.21 / 40.66 | 2 | 2 |
2 | 7 | 2002.48 | 52 | 15.24 | 3134 | 2484 | 2.69 / 43.14 | 2 | 2 |
3 | 13 | 977.52 | 18 | 15.34 | 1734 | 479 | 3.17 / 43.62 | 2 | 2 |
4 | 13 | 247.80 | 18 | 15.53 | 686 | 192 | 3.36 / 43.81 | 2 | 2 |
5 | 13 | 23.52 | 18 | 15.59 | 329 | 92 | 3.45 / 43.90 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.55 | 282 | 724 | 4.18 / 44.63 | 2 | 3 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 28 | 15.50 | 475 | 206 | 0.21 / 36.45 | 2 | 2 |
2 | 7 | 2003.24 | 53 | 15.24 | 3147 | 2542 | 2.75 / 38.99 | 2 | 2 |
3 | 13 | 858.20 | 18 | 15.38 | 1565 | 433 | 3.18 / 39.43 | 2 | 2 |
4 | 13 | 278.72 | 18 | 15.52 | 731 | 204 | 3.39 / 39.63 | 2 | 2 |
5 | 13 | 23.52 | 18 | 15.59 | 330 | 93 | 3.48 / 39.72 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.54 | 283 | 726 | 4.20 / 40.45 | 2 | 2 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 27 | 15.50 | 476 | 199 | 0.20 / 32.23 | 2 | 2 |
2 | 7 | 2006.64 | 53 | 15.23 | 3136 | 2531 | 2.73 / 34.76 | 2 | 2 |
3 | 13 | 982.96 | 18 | 15.33 | 1736 | 479 | 3.21 / 35.24 | 2 | 2 |
4 | 13 | 245.84 | 18 | 15.54 | 680 | 190 | 3.40 / 35.43 | 2 | 2 |
5 | 13 | 21.40 | 18 | 15.60 | 327 | 92 | 3.49 / 35.52 | 2 | 2 |
6 | 8 | 0.04 | 165 | 15.56 | 281 | 721 | 4.21 / 36.25 | 2 | 2 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 27 | 15.50 | 477 | 200 | 0.20 / 28.02 | 2 | 2 |
2 | 7 | 2007.64 | 53 | 15.24 | 3149 | 2544 | 2.74 / 30.57 | 2 | 2 |
3 | 13 | 861.04 | 18 | 15.37 | 1573 | 435 | 3.18 / 31.00 | 2 | 2 |
4 | 13 | 280.28 | 18 | 15.53 | 737 | 206 | 3.38 / 31.21 | 2 | 3 |
5 | 13 | 25.68 | 18 | 15.59 | 335 | 94 | 3.48 / 31.30 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.56 | 284 | 729 | 4.21 / 32.03 | 2 | 3 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 27 | 15.50 | 470 | 197 | 0.20 / 23.88 | 2 | 2 |
2 | 7 | 2006.92 | 53 | 15.23 | 3148 | 2541 | 2.74 / 26.42 | 2 | 2 |
3 | 13 | 989.32 | 18 | 15.34 | 1749 | 483 | 3.22 / 26.91 | 2 | 2 |
4 | 13 | 241.48 | 18 | 15.54 | 675 | 189 | 3.41 / 27.10 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.57 | 284 | 730 | 4.14 / 27.82 | 2 | 2 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.24 | 26 | 15.52 | 472 | 190 | 0.19 / 19.78 | 2 | 2 |
2 | 10 | 1013.12 | 2 | 15.45 | 1833 | 57 | 0.25 / 19.84 | 2 | 2 |
3 | 7 | 2002.96 | 53 | 15.24 | 3139 | 2535 | 2.78 / 22.37 | 2 | 2 |
4 | 13 | 865.60 | 18 | 15.37 | 1569 | 434 | 3.22 / 22.81 | 2 | 2 |
5 | 13 | 159.40 | 18 | 15.56 | 551 | 154 | 3.37 / 22.96 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.57 | 282 | 724 | 4.10 / 23.69 | 2 | 2 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 25 | 15.52 | 478 | 185 | 0.19 / 15.66 | 2 | 2 |
2 | 10 | 1027.08 | 2 | 15.46 | 1859 | 57 | 0.24 / 15.71 | 2 | 2 |
3 | 7 | 2003.88 | 53 | 15.24 | 3128 | 2527 | 2.77 / 18.24 | 2 | 2 |
4 | 13 | 843.28 | 18 | 15.40 | 1542 | 427 | 3.20 / 18.67 | 2 | 2 |
5 | 13 | 253.28 | 18 | 15.55 | 693 | 194 | 3.39 / 18.86 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.56 | 284 | 729 | 4.12 / 19.59 | 2 | 2 |
Average= | 3.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 27 | 15.51 | 473 | 198 | 0.20 / 12.24 | 2 | 2 |
2 | 3 | 962.20 | -1 | 15.86 | 3 | 0 | 0.00 / 12.24 | 2 | 2 |
3 | 7 | 1519.28 | 52 | 15.37 | 2473 | 1977 | 2.17 / 14.22 | 2 | 2 |
4 | 13 | 742.68 | 18 | 15.44 | 1397 | 388 | 2.56 / 14.60 | 2 | 2 |
5 | 13 | 133.40 | 18 | 15.57 | 508 | 142 | 2.71 / 14.75 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.57 | 282 | 724 | 3.43 / 15.47 | 2 | 3 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 26 | 15.51 | 470 | 190 | 0.19 / 8.44 | 2 | 2 |
2 | 7 | 1524.00 | 74 | 15.18 | 2453 | 2756 | 2.95 / 11.20 | 2 | 2 |
3 | 13 | 98.96 | 18 | 15.59 | 452 | 127 | 3.07 / 11.32 | 2 | 3 |
4 | 8 | 0.00 | 165 | 15.57 | 279 | 717 | 3.79 / 12.04 | 2 | 2 |
Average= | 3.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 26 | 15.55 | 467 | 189 | 0.19 / 4.66 | 2 | 2 |
2 | 7 | 1521.60 | 74 | 15.19 | 2446 | 2749 | 2.94 / 7.41 | 2 | 2 |
3 | 13 | 95.24 | 18 | 15.60 | 446 | 125 | 3.06 / 7.54 | 2 | 2 |
4 | 8 | 0.20 | 165 | 15.59 | 278 | 715 | 3.78 / 8.25 | 2 | 2 |
Average= | 2.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 23 | 15.72 | 424 | 153 | 0.15 / 1.68 | 2 | 3 |
2 | 10 | 1002.12 | 3 | 15.53 | 1800 | 84 | 0.24 / 1.76 | 2 | 2 |
3 | 3 | 1021.84 | 1 | 15.57 | 1847 | 29 | 0.27 / 1.79 | 2 | 2 |
4 | 7 | 1007.84 | 74 | 15.37 | 1727 | 1964 | 2.23 / 3.76 | 2 | 2 |
5 | 8 | 0.16 | 165 | 15.62 | 278 | 716 | 2.95 / 4.47 | 2 | 3 |
Average= | 2.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 73.32 | 22 | 15.84 | 381 | 133 | 0.13 / 0.13 | 2 | 3 |
2 | 7 | 86.80 | 74 | 15.81 | 392 | 459 | 0.59 / 0.59 | 2 | 2 |
3 | 8 | 0.16 | 240 | 15.78 | 247 | 935 | 1.53 / 1.53 | 2 | 7 |
Average= | 1.53 (KJ/cycle) |