SIO Argo Site:
Pump Diagnostics Page   



Serial= 8808 WMO= 5906119

Return

←PreviousNext→

Cycle 185 GMT 7/11/2024 3:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 32 15.08 512 247 0.25 / 817.99 3 3
2 7 2004.92 53 14.92 3188 2521 2.77 / 820.51 2 2
3 13 1028.40 16 14.93 1867 446 3.21 / 820.96 2 3
4 13 461.08 16 15.04 1054 254 3.47 / 821.21 2 3
5 13 17.80 16 15.16 375 91 3.56 / 821.31 2 3
6 8 -0.24 165 15.12 332 828 4.39 / 822.13 2 7
7 14 -0.24 30 15.10 332 150 4.54 / 822.28 2 7
Average= 4.42
(KJ/cycle)

Cycle 184 GMT 28/10/2024 8:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 32 15.07 499 241 0.24 / 813.69 3 3
2 7 2008.88 53 14.93 3203 2535 2.78 / 816.23 2 2
3 13 1023.20 16 14.92 1848 441 3.22 / 816.67 2 3
4 13 462.00 16 15.04 1041 251 3.47 / 816.92 2 3
5 8 0.08 165 15.14 331 827 4.29 / 817.75 2 7
Average= 4.42
(KJ/cycle)

Cycle 183 GMT 18/10/2024 13:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 32 15.07 506 244 0.24 / 809.31 3 3
2 7 2004.00 53 14.93 3195 2528 2.77 / 811.84 2 2
3 13 1036.24 16 14.91 1874 447 3.22 / 812.29 2 3
4 13 465.88 16 15.03 1054 253 3.47 / 812.54 2 3
5 13 42.28 16 15.15 409 99 3.57 / 812.64 2 3
6 8 -0.12 165 15.13 325 811 4.38 / 813.45 2 5
Average= 4.42
(KJ/cycle)

Cycle 182 GMT 8/10/2024 19: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 31 15.08 509 238 0.24 / 805.02 2 3
2 7 2003.16 53 14.93 3188 2523 2.76 / 807.55 2 2
3 13 1036.24 16 14.92 1875 448 3.21 / 808.00 2 3
4 13 472.80 16 15.04 1062 256 3.46 / 808.25 2 3
5 8 0.24 165 15.14 328 819 4.28 / 809.07 2 7
Average= 4.42
(KJ/cycle)

Cycle 181 GMT 29/ 9/2024 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 31 15.07 505 236 0.24 / 800.43 2 3
2 7 2002.60 53 14.94 3191 2527 2.76 / 802.96 2 2
3 13 1030.84 16 14.92 1865 445 3.21 / 803.40 2 3
4 13 601.24 16 15.00 1239 297 3.51 / 803.70 2 3
5 13 64.28 16 15.16 441 107 3.61 / 803.81 2 3
6 8 0.12 165 15.12 332 828 4.44 / 804.64 2 3
7 14 0.12 30 15.10 331 150 4.59 / 804.79 3 9
Average= 4.42
(KJ/cycle)

Cycle 180 GMT 19/ 9/2024 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 31 15.07 513 240 0.24 / 796.01 2 3
2 7 2003.48 53 14.91 3180 2513 2.75 / 798.53 2 2
3 13 1040.68 16 14.90 1876 447 3.20 / 798.97 2 3
4 13 616.48 16 14.99 1271 305 3.50 / 799.28 2 3
5 13 33.60 16 15.15 399 97 3.60 / 799.38 2 3
6 8 -0.20 165 15.12 329 821 4.42 / 800.20 2 4
Average= 4.42
(KJ/cycle)

Cycle 179 GMT 9/ 9/2024 10:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 31 15.07 503 235 0.23 / 791.62 3 3
2 7 2005.64 53 14.93 3192 2526 2.76 / 794.15 2 2
3 13 1033.88 16 14.92 1877 448 3.21 / 794.60 2 3
4 13 486.12 16 15.04 1075 259 3.47 / 794.86 2 3
5 13 43.80 16 15.15 407 99 3.57 / 794.96 2 3
6 8 -0.12 165 15.12 328 818 4.38 / 795.77 2 5
Average= 4.42
(KJ/cycle)

Cycle 178 GMT 30/ 8/2024 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 31 15.08 507 237 0.24 / 787.06 2 3
2 7 2009.40 53 14.93 3198 2531 2.77 / 789.59 2 2
3 13 1055.20 16 14.91 1897 453 3.22 / 790.04 2 3
4 13 493.08 16 15.03 1081 260 3.48 / 790.30 2 3
5 13 43.12 16 15.15 413 100 3.58 / 790.40 2 3
6 8 0.08 165 15.13 335 836 4.42 / 791.24 3 11
7 14 0.08 30 15.11 332 150 4.57 / 791.39 2 6
Average= 4.42
(KJ/cycle)

Cycle 177 GMT 20/ 8/2024 21: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 31 15.08 503 235 0.24 / 782.69 3 3
2 7 2009.36 53 14.92 3202 2532 2.77 / 785.22 2 2
3 13 1165.52 16 14.88 2048 488 3.25 / 785.71 2 3
4 13 579.00 16 15.00 1218 292 3.55 / 786.00 2 3
5 8 0.16 165 15.13 330 824 4.37 / 786.82 2 7
Average= 4.42
(KJ/cycle)

Cycle 176 GMT 11/ 8/2024 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 31 15.08 493 230 0.23 / 778.39 2 3
2 7 2010.44 53 14.93 3195 2528 2.76 / 780.92 2 2
3 13 1045.48 16 14.92 1882 449 3.21 / 781.37 2 3
4 13 483.92 16 15.03 1075 259 3.47 / 781.63 2 3
5 8 0.16 165 15.14 329 822 4.29 / 782.45 2 7
Average= 4.42
(KJ/cycle)

Cycle 175 GMT 1/ 8/2024 7:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 31 15.09 508 238 0.24 / 773.97 3 3
2 7 2004.24 53 14.95 3190 2528 2.77 / 776.50 2 2
3 13 1040.44 16 14.93 1873 447 3.21 / 776.95 2 3
4 13 486.28 16 15.05 1073 258 3.47 / 777.21 2 3
5 8 0.08 165 15.15 324 810 4.28 / 778.02 2 5
6 14 0.08 30 15.12 325 147 4.43 / 778.16 2 6
Average= 4.42
(KJ/cycle)

Cycle 174 GMT 22/ 7/2024 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 31 15.07 500 234 0.23 / 769.65 2 3
2 7 2009.52 52 14.92 3190 2475 2.71 / 772.12 2 2
3 13 1037.60 16 14.92 1863 445 3.15 / 772.57 2 3
4 13 478.92 16 15.05 1068 257 3.41 / 772.83 2 3
5 13 39.28 16 15.17 401 97 3.51 / 772.92 2 3
6 8 0.00 165 15.14 325 812 4.32 / 773.74 3 7
Average= 4.42
(KJ/cycle)

Cycle 173 GMT 12/ 7/2024 17:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 31 15.08 505 236 0.24 / 765.21 3 3
2 7 2002.76 53 14.93 3187 2522 2.76 / 767.73 2 2
3 13 1058.04 16 14.91 1905 454 3.21 / 768.19 2 3
4 13 622.20 16 15.00 1275 306 3.52 / 768.49 2 3
5 13 70.12 16 15.16 450 109 3.63 / 768.60 2 3
6 8 0.08 165 15.13 326 814 4.44 / 769.42 2 7
Average= 4.42
(KJ/cycle)

Cycle 172 GMT 2/ 7/2024 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 31 15.09 497 232 0.23 / 760.77 3 3
2 7 2003.84 53 14.93 3203 2535 2.77 / 763.30 2 2
3 13 1046.76 16 14.92 1889 451 3.22 / 763.75 2 3
4 13 611.00 16 15.01 1264 304 3.52 / 764.05 2 3
5 13 66.56 16 15.15 446 108 3.63 / 764.16 2 3
6 8 0.20 165 15.13 325 811 4.44 / 764.97 2 6
Average= 4.42
(KJ/cycle)

Cycle 171 GMT 23/ 6/2024 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 31 15.07 502 235 0.23 / 756.23 3 3
2 7 2006.36 53 14.92 3190 2523 2.76 / 758.75 2 2
3 13 1040.12 16 14.93 1883 450 3.21 / 759.20 2 3
4 13 483.04 16 15.05 1079 260 3.47 / 759.46 2 3
5 13 43.88 16 15.17 413 100 3.57 / 759.56 2 3
6 8 0.08 165 15.14 329 822 4.39 / 760.38 2 8
7 14 0.08 30 15.12 328 149 4.54 / 760.53 3 7
Average= 4.42
(KJ/cycle)

Cycle 170 GMT 13/ 6/2024 9:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 31 15.08 507 237 0.24 / 751.65 3 3
2 7 2004.48 53 14.94 3194 2529 2.77 / 754.18 2 2
3 13 1036.88 16 14.92 1878 448 3.21 / 754.63 2 3
4 13 594.72 16 15.02 1245 299 3.51 / 754.93 2 3
5 13 60.44 16 15.17 439 107 3.62 / 755.03 2 3
6 8 0.12 165 15.14 326 814 4.43 / 755.85 2 4
7 14 0.12 30 15.12 324 147 4.58 / 756.00 3 7
Average= 4.42
(KJ/cycle)

Cycle 169 GMT 3/ 6/2024 14:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 31 15.09 496 232 0.23 / 747.21 3 3
2 7 2010.60 53 14.94 3201 2535 2.77 / 749.75 2 2
3 13 1031.48 16 14.92 1865 445 3.21 / 750.19 2 3
4 13 600.44 16 15.01 1243 299 3.51 / 750.49 2 3
5 13 59.04 16 15.16 433 105 3.62 / 750.60 2 3
6 8 0.00 165 15.13 327 816 4.43 / 751.41 2 6
Average= 4.42
(KJ/cycle)

Cycle 168 GMT 24/ 5/2024 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 31 15.09 505 236 0.24 / 742.83 3 3
2 7 2003.20 53 14.93 3186 2521 2.76 / 745.35 2 2
3 13 1053.92 16 14.92 1895 452 3.21 / 745.80 2 3
4 13 487.60 16 15.04 1084 261 3.47 / 746.06 2 3
5 13 85.84 16 15.15 474 115 3.59 / 746.18 2 2
6 8 0.00 165 15.13 323 806 4.39 / 746.98 2 6
Average= 4.42
(KJ/cycle)

Cycle 167 GMT 15/ 5/2024 0:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 31 15.08 494 231 0.23 / 738.50 3 3
2 7 2003.64 52 14.94 3180 2470 2.70 / 740.97 2 2
3 13 1034.20 16 14.93 1865 446 3.15 / 741.42 2 3
4 13 471.68 16 15.05 1056 254 3.40 / 741.67 2 3
5 13 44.88 16 15.17 415 101 3.50 / 741.77 2 3
6 8 0.16 165 15.14 328 819 4.32 / 742.59 2 4
Average= 4.42
(KJ/cycle)

Cycle 166 GMT 5/ 5/2024 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 31 15.10 473 221 0.22 / 734.04 3 3
2 7 2004.40 52 14.93 3187 2474 2.70 / 736.52 2 2
3 13 1037.56 16 14.93 1869 446 3.14 / 736.96 2 3
4 13 482.56 16 15.04 1071 258 3.40 / 737.22 2 3
5 13 47.36 16 15.17 412 100 3.50 / 737.32 2 3
6 8 0.00 165 15.14 321 802 4.30 / 738.12 2 9
7 14 0.00 30 15.11 323 146 4.45 / 738.27 3 8
Average= 4.42
(KJ/cycle)

Cycle 165 GMT 25/ 4/2024 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 31 15.09 500 234 0.23 / 729.70 3 3
2 7 2005.16 53 14.94 3184 2521 2.76 / 732.22 2 2
3 13 1046.56 16 14.92 1874 447 3.20 / 732.67 2 3
4 13 470.84 16 15.05 1057 255 3.46 / 732.92 2 3
5 13 49.60 16 15.17 415 101 3.56 / 733.02 2 3
6 8 0.00 165 15.14 320 799 4.36 / 733.82 2 4
Average= 4.42
(KJ/cycle)

Cycle 164 GMT 15/ 4/2024 15:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 31 15.09 499 233 0.23 / 725.33 3 3
2 7 2004.60 53 14.93 3197 2530 2.76 / 727.86 2 2
3 13 1028.76 16 14.92 1859 444 3.21 / 728.30 2 3
4 13 466.24 16 15.04 1056 254 3.46 / 728.56 2 3
5 13 47.92 16 15.16 416 101 3.56 / 728.66 2 3
6 8 0.12 165 15.14 323 807 4.37 / 729.46 2 6
Average= 4.42
(KJ/cycle)

Cycle 163 GMT 5/ 4/2024 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 31 15.10 491 230 0.23 / 720.95 2 3
2 7 2009.04 53 14.92 3189 2522 2.75 / 723.47 2 2
3 13 1056.96 16 14.91 1906 455 3.21 / 723.93 2 3
4 13 491.84 16 15.03 1095 263 3.47 / 724.19 2 3
5 13 51.32 16 15.16 421 102 3.57 / 724.29 2 3
6 8 -0.04 165 15.14 322 804 4.38 / 725.10 3 7
Average= 4.42
(KJ/cycle)

Cycle 162 GMT 27/ 3/2024 2: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 31 15.10 504 236 0.24 / 716.57 3 3
2 7 2010.28 53 14.93 3207 2538 2.77 / 719.11 2 2
3 13 1034.88 16 14.92 1869 446 3.22 / 719.55 2 3
4 13 492.60 16 15.04 1089 262 3.48 / 719.81 2 3
5 13 52.28 16 15.18 422 102 3.58 / 719.92 2 3
6 8 0.12 165 15.16 321 803 4.39 / 720.72 2 6
Average= 4.42
(KJ/cycle)

Cycle 161 GMT 17/ 3/2024 6:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 31 15.10 504 236 0.24 / 712.19 3 3
2 7 2010.24 53 14.93 3187 2522 2.76 / 714.71 2 2
3 13 1034.16 16 14.93 1870 447 3.20 / 715.16 2 3
4 13 469.56 16 15.07 1058 255 3.46 / 715.41 2 3
5 13 48.12 16 15.17 422 102 3.56 / 715.51 2 3
6 8 0.04 165 15.15 327 817 4.38 / 716.33 3 6
Average= 4.42
(KJ/cycle)

Cycle 160 GMT 7/ 3/2024 11:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 31 15.10 477 223 0.22 / 707.77 3 3
2 7 2009.92 53 14.94 3191 2527 2.75 / 710.29 2 2
3 13 1017.40 16 14.93 1842 440 3.19 / 710.73 2 3
4 13 589.44 16 15.03 1223 294 3.48 / 711.03 2 3
5 13 58.56 16 15.17 437 106 3.59 / 711.13 2 3
6 8 -0.04 165 15.14 328 819 4.41 / 711.95 2 5
Average= 4.42
(KJ/cycle)

Cycle 159 GMT 26/ 2/2024 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 31 15.11 491 230 0.23 / 703.39 3 3
2 7 2012.76 53 14.95 3199 2535 2.76 / 705.93 2 2
3 13 1035.08 16 14.93 1871 447 3.21 / 706.37 2 3
4 13 462.76 16 15.07 1047 252 3.46 / 706.62 2 3
5 13 80.48 16 15.17 466 113 3.58 / 706.74 2 3
6 8 0.12 165 15.15 322 805 4.38 / 707.54 2 6
Average= 4.42
(KJ/cycle)

Cycle 158 GMT 16/ 2/2024 21:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 31 15.10 491 230 0.23 / 698.97 2 3
2 7 2004.24 53 14.94 3181 2519 2.75 / 701.49 2 2
3 13 1159.68 16 14.91 2036 486 3.23 / 701.98 2 3
4 13 567.40 16 15.03 1192 287 3.52 / 702.26 2 3
5 13 55.20 16 15.18 423 103 3.62 / 702.37 2 3
6 8 0.36 165 15.16 318 795 4.42 / 703.16 2 8
Average= 4.42
(KJ/cycle)

Cycle 157 GMT 7/ 2/2024 2:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 31 15.09 503 235 0.24 / 694.48 2 3
2 7 2003.72 53 14.93 3172 2510 2.75 / 696.99 2 2
3 13 1047.12 16 14.94 1893 453 3.20 / 697.44 2 3
4 13 487.40 16 15.04 1076 259 3.46 / 697.70 2 3
5 13 45.08 16 15.17 411 100 3.56 / 697.80 2 2
6 8 0.20 165 15.16 319 798 4.35 / 698.60 2 6
7 14 0.20 30 15.14 317 144 4.50 / 698.74 2 7
Average= 4.42
(KJ/cycle)

Cycle 156 GMT 28/ 1/2024 7:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 31 15.10 495 232 0.23 / 690.15 3 3
2 7 2002.24 52 14.94 3192 2480 2.71 / 692.63 2 2
3 13 1032.32 16 14.94 1857 444 3.16 / 693.08 2 3
4 13 482.84 16 15.05 1073 258 3.41 / 693.34 2 3
5 13 49.84 16 15.18 414 101 3.51 / 693.44 2 3
6 8 -0.04 165 15.15 323 807 4.32 / 694.24 2 7
Average= 4.42
(KJ/cycle)

Cycle 155 GMT 18/ 1/2024 10:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 31 15.10 510 239 0.24 / 685.80 3 3
2 7 2004.48 53 14.94 3178 2516 2.76 / 688.32 2 2
3 13 1035.52 16 14.94 1866 446 3.20 / 688.77 2 3
4 13 477.96 16 15.06 1068 257 3.46 / 689.02 2 3
5 13 41.60 16 15.18 402 98 3.56 / 689.12 2 3
6 8 0.16 165 15.15 320 800 4.36 / 689.92 2 7
Average= 4.42
(KJ/cycle)

Cycle 154 GMT 8/ 1/2024 12:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 31 15.10 510 239 0.24 / 681.42 3 3
2 7 2003.48 53 14.95 3174 2515 2.75 / 683.94 2 2
3 13 1028.56 16 14.95 1859 445 3.20 / 684.38 2 3
4 13 465.32 16 15.07 1057 255 3.45 / 684.64 2 3
5 13 40.24 16 15.19 408 99 3.55 / 684.74 2 3
6 8 0.08 165 15.15 331 827 4.38 / 685.57 2 7
Average= 4.42
(KJ/cycle)

Cycle 153 GMT 29/12/2023 15:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 31 15.10 508 238 0.24 / 676.95 3 3
2 7 2007.12 54 14.95 3188 2574 2.81 / 679.52 2 2
3 13 1022.24 16 14.94 1851 442 3.25 / 679.96 2 3
4 13 578.52 16 15.04 1212 292 3.55 / 680.25 2 3
5 13 30.20 16 15.20 392 95 3.64 / 680.35 2 3
6 8 0.00 165 15.16 334 835 4.48 / 681.19 2 6
Average= 4.42
(KJ/cycle)

Cycle 152 GMT 19/12/2023 17:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 31 15.11 508 238 0.24 / 672.57 3 3
2 3 1017.40 1 15.27 1919 29 0.27 / 672.60 2 2
3 7 2002.56 52 14.96 3183 2476 2.74 / 675.08 2 2
4 13 1030.20 16 14.95 1863 446 3.19 / 675.52 2 3
5 13 477.80 16 15.07 1072 258 3.45 / 675.78 2 3
6 13 44.16 16 15.18 416 101 3.55 / 675.88 2 3
7 8 -0.04 165 15.16 330 825 4.37 / 676.71 2 5
Average= 4.42
(KJ/cycle)

Cycle 151 GMT 9/12/2023 20:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 31 15.10 525 246 0.25 / 668.19 2 3
2 7 2003.44 53 14.95 3197 2533 2.78 / 670.72 2 2
3 13 1028.88 16 14.94 1862 445 3.22 / 671.16 2 3
4 13 460.20 16 15.07 1046 252 3.48 / 671.42 2 3
5 13 36.88 16 15.20 403 98 3.57 / 671.51 2 3
6 8 0.16 165 15.17 328 821 4.40 / 672.34 2 5
Average= 4.42
(KJ/cycle)

Cycle 150 GMT 29/11/2023 22:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 31 15.13 519 243 0.24 / 663.76 2 3
2 7 2004.32 53 14.95 3187 2525 2.77 / 666.28 2 2
3 13 1026.28 16 14.95 1863 446 3.21 / 666.73 2 3
4 13 462.36 16 15.06 1056 254 3.47 / 666.98 2 3
5 13 35.08 16 15.19 413 100 3.57 / 667.08 2 3
6 8 -0.08 165 15.16 343 858 4.43 / 667.94 2 3
Average= 4.42
(KJ/cycle)

Cycle 149 GMT 20/11/2023 1:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 31 15.10 524 245 0.25 / 659.44 2 3
2 7 2004.44 53 14.95 3185 2524 2.77 / 661.96 2 2
3 13 1043.56 16 14.95 1899 454 3.22 / 662.42 2 3
4 13 476.08 16 15.07 1079 260 3.48 / 662.68 2 3
5 8 0.20 165 15.17 334 836 4.32 / 663.51 2 8
Average= 4.42
(KJ/cycle)

Cycle 148 GMT 10/11/2023 3:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 31 15.10 525 246 0.25 / 654.99 2 3
2 7 2003.60 53 14.95 3210 2543 2.79 / 657.53 2 2
3 13 1033.08 16 14.94 1884 450 3.24 / 657.98 2 3
4 13 472.68 16 15.06 1078 260 3.50 / 658.24 2 3
5 13 38.04 16 15.19 416 101 3.60 / 658.35 2 3
6 8 -0.12 165 15.16 339 848 4.45 / 659.19 2 6
Average= 4.42
(KJ/cycle)

Cycle 147 GMT 31/10/2023 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 31 15.10 524 245 0.25 / 650.56 2 3
2 7 2003.96 53 14.94 3194 2529 2.77 / 653.09 2 2
3 13 1040.08 16 14.94 1886 451 3.23 / 653.54 2 3
4 13 479.84 16 15.06 1081 260 3.49 / 653.80 2 3
5 13 19.64 16 15.18 382 93 3.58 / 653.89 2 3
6 8 0.20 165 15.15 341 852 4.43 / 654.75 2 4
Average= 4.42
(KJ/cycle)

Cycle 146 GMT 21/10/2023 8:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 31 15.10 511 239 0.24 / 646.14 2 3
2 7 2002.32 53 14.94 3197 2531 2.77 / 648.68 2 2
3 13 1028.32 16 14.93 1869 446 3.22 / 649.12 2 3
4 13 462.88 16 15.07 1049 253 3.47 / 649.38 2 3
5 13 37.16 16 15.19 407 99 3.57 / 649.47 2 2
6 8 0.16 165 15.16 336 840 4.41 / 650.31 2 4
Average= 4.42
(KJ/cycle)

Cycle 145 GMT 11/10/2023 11:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 31 15.11 513 240 0.24 / 641.71 2 3
2 7 2006.96 53 14.96 3197 2535 2.78 / 644.24 2 2
3 13 1044.12 16 14.96 1897 454 3.23 / 644.70 2 3
4 13 482.56 16 15.08 1081 261 3.49 / 644.96 2 3
5 13 41.44 16 15.21 416 101 3.59 / 645.06 2 3
6 8 0.04 165 15.17 338 846 4.44 / 645.91 2 8
Average= 4.42
(KJ/cycle)

Cycle 144 GMT 1/10/2023 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 31 15.11 507 237 0.24 / 637.15 2 3
2 7 2005.88 53 14.95 3196 2532 2.77 / 639.69 2 2
3 13 1020.84 16 14.96 1848 442 3.21 / 640.13 2 3
4 13 469.12 16 15.09 1053 254 3.47 / 640.38 2 3
5 13 19.56 16 15.21 372 91 3.56 / 640.47 2 3
6 8 0.16 165 15.17 336 841 4.40 / 641.31 2 5
7 14 0.16 30 15.15 337 153 4.55 / 641.47 3 9
Average= 4.42
(KJ/cycle)

Cycle 143 GMT 21/ 9/2023 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 31 15.13 501 235 0.23 / 632.76 2 3
2 7 2006.64 53 14.95 3185 2524 2.76 / 635.28 2 2
3 13 1024.48 16 14.95 1860 445 3.20 / 635.73 2 3
4 13 466.88 16 15.07 1056 255 3.46 / 635.98 2 3
5 13 37.16 16 15.20 408 99 3.56 / 636.08 2 2
6 8 0.04 165 15.17 333 834 4.39 / 636.92 2 7
Average= 4.42
(KJ/cycle)

Cycle 142 GMT 11/ 9/2023 18:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 31 15.12 523 245 0.25 / 628.30 2 3
2 7 2011.08 53 14.95 3192 2529 2.77 / 630.83 2 2
3 13 1039.72 16 14.96 1881 450 3.22 / 631.28 2 3
4 13 462.64 16 15.09 1050 254 3.48 / 631.54 2 3
5 8 0.20 165 15.17 335 839 4.32 / 632.37 2 11
6 14 0.20 30 15.15 334 152 4.47 / 632.53 2 9
Average= 4.42
(KJ/cycle)

Cycle 141 GMT 1/ 9/2023 20:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 31 15.13 511 240 0.24 / 623.81 2 3
2 7 2009.36 53 14.97 3215 2551 2.79 / 626.36 2 2
3 13 1021.48 16 14.96 1862 446 3.24 / 626.81 2 3
4 13 454.60 16 15.09 1046 253 3.49 / 627.06 2 3
5 8 -0.08 165 15.18 336 842 4.33 / 627.90 2 7
6 14 -0.08 30 15.15 339 154 4.48 / 628.06 3 8
Average= 4.42
(KJ/cycle)

Cycle 140 GMT 22/ 8/2023 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 31 15.12 513 240 0.24 / 619.46 2 3
2 7 2003.64 53 14.96 3191 2530 2.77 / 621.99 2 2
3 13 1021.52 16 14.97 1868 447 3.22 / 622.43 2 3
4 13 594.60 16 15.06 1243 300 3.52 / 622.73 2 3
5 8 0.28 165 15.18 335 839 4.36 / 623.57 2 4
Average= 4.42
(KJ/cycle)

Cycle 139 GMT 13/ 8/2023 1:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 31 15.13 521 244 0.24 / 615.04 3 3
2 7 2003.80 53 14.98 3202 2542 2.79 / 617.58 2 2
3 13 1021.68 16 14.96 1852 443 3.23 / 618.02 2 3
4 13 463.40 16 15.10 1051 254 3.48 / 618.28 2 3
5 13 16.56 16 15.21 374 91 3.57 / 618.37 2 3
6 8 -0.16 165 15.18 338 847 4.42 / 619.22 2 11
Average= 4.42
(KJ/cycle)

Cycle 138 GMT 3/ 8/2023 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 31 15.12 527 247 0.25 / 610.66 2 3
2 7 2012.12 52 14.95 3206 2492 2.74 / 613.15 2 2
3 13 1037.96 16 14.96 1883 451 3.19 / 613.60 2 3
4 13 466.80 16 15.09 1058 255 3.45 / 613.85 2 3
5 13 35.68 16 15.21 407 99 3.54 / 613.95 2 3
6 8 0.12 165 15.17 336 841 4.39 / 614.80 2 7
Average= 4.42
(KJ/cycle)

Cycle 137 GMT 24/ 7/2023 6:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 31 15.12 526 247 0.25 / 606.21 2 3
2 7 2010.84 53 14.96 3194 2532 2.78 / 608.74 2 2
3 13 1044.92 16 14.95 1887 451 3.23 / 609.19 2 3
4 13 475.72 16 15.08 1073 259 3.49 / 609.45 2 3
5 13 78.80 16 15.19 476 116 3.60 / 609.57 2 3
6 8 0.12 165 15.17 337 844 4.45 / 610.41 2 6
Average= 4.42
(KJ/cycle)

Cycle 136 GMT 14/ 7/2023 9: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 31 15.11 523 245 0.24 / 601.77 3 3
2 7 2003.60 53 14.97 3199 2538 2.78 / 604.31 2 2
3 13 1030.36 16 14.97 1875 449 3.23 / 604.76 2 3
4 13 468.64 16 15.10 1072 259 3.49 / 605.02 2 3
5 13 17.08 16 15.21 381 93 3.58 / 605.11 2 3
6 8 0.00 165 15.18 340 852 4.44 / 605.96 2 5
Average= 4.42
(KJ/cycle)

Cycle 135 GMT 4/ 7/2023 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 31 15.12 514 241 0.24 / 597.34 2 3
2 7 2005.80 53 14.97 3190 2531 2.77 / 599.87 2 2
3 13 1035.48 16 14.96 1875 449 3.22 / 600.32 2 3
4 13 482.44 16 15.08 1083 261 3.48 / 600.58 2 3
5 13 41.04 16 15.21 420 102 3.58 / 600.68 2 2
6 8 0.00 165 15.18 338 847 4.43 / 601.53 2 5
Average= 4.42
(KJ/cycle)

Cycle 134 GMT 24/ 6/2023 13:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 31 15.11 516 242 0.24 / 592.70 2 3
2 7 2003.76 53 14.95 3195 2532 2.77 / 595.24 2 2
3 13 1028.88 16 14.96 1873 448 3.22 / 595.68 2 3
4 13 597.32 16 15.04 1252 301 3.52 / 595.99 2 3
5 13 59.68 16 15.20 448 109 3.63 / 596.09 2 3
6 8 0.16 165 15.17 338 846 4.48 / 596.94 2 5
7 14 0.16 30 15.15 339 154 4.63 / 597.09 2 10
Average= 4.42
(KJ/cycle)

Cycle 133 GMT 14/ 6/2023 16:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 31 15.11 519 243 0.24 / 588.26 3 3
2 7 2007.60 53 14.95 3208 2542 2.78 / 590.80 2 2
3 13 1016.56 16 14.97 1855 444 3.23 / 591.25 2 3
4 13 459.68 16 15.09 1054 254 3.48 / 591.50 2 3
5 13 72.48 16 15.20 466 113 3.60 / 591.62 2 3
6 8 0.00 165 15.17 338 846 4.44 / 592.46 2 8
Average= 4.42
(KJ/cycle)

Cycle 132 GMT 4/ 6/2023 18:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 31 15.11 528 247 0.25 / 583.84 2 3
2 7 2010.56 53 14.95 3202 2537 2.78 / 586.37 2 2
3 13 1035.68 16 14.96 1875 449 3.23 / 586.82 2 3
4 13 477.56 16 15.09 1079 261 3.49 / 587.08 2 3
5 13 18.68 16 15.22 378 92 3.59 / 587.18 2 4
6 8 0.20 165 15.18 337 844 4.43 / 588.02 2 8
Average= 4.42
(KJ/cycle)

Cycle 131 GMT 25/ 5/2023 21:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 31 15.11 532 249 0.25 / 579.39 2 3
2 7 2004.76 53 14.95 3199 2535 2.78 / 581.93 2 2
3 13 1029.68 16 14.96 1881 450 3.23 / 582.38 2 3
4 13 468.44 16 15.09 1076 260 3.49 / 582.64 2 3
5 13 38.28 16 15.20 419 102 3.60 / 582.74 2 3
6 8 0.16 165 15.17 340 851 4.45 / 583.59 2 7
Average= 4.42
(KJ/cycle)

Cycle 130 GMT 15/ 5/2023 23:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 31 15.12 531 249 0.25 / 574.92 3 3
2 7 2010.68 53 14.96 3197 2535 2.78 / 577.45 2 2
3 13 1045.72 16 14.96 1894 453 3.24 / 577.90 2 3
4 13 474.24 16 15.09 1079 261 3.50 / 578.17 2 3
5 13 48.08 16 15.20 436 106 3.60 / 578.27 2 3
6 8 0.00 165 15.18 348 872 4.48 / 579.14 2 6
Average= 4.42
(KJ/cycle)

Cycle 129 GMT 6/ 5/2023 2:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 31 15.12 525 246 0.25 / 570.39 2 3
2 3 1016.08 1 15.27 1912 29 0.28 / 570.42 2 2
3 7 2012.36 53 14.97 3224 2558 2.83 / 572.98 2 2
4 13 1018.76 16 14.97 1863 446 3.28 / 573.42 2 3
5 13 452.96 16 15.10 1050 254 3.53 / 573.68 2 3
6 13 67.72 16 15.20 471 115 3.65 / 573.79 2 3
7 8 0.32 165 15.18 350 877 4.52 / 574.67 2 8
Average= 4.42
(KJ/cycle)

Cycle 128 GMT 26/ 4/2023 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 31 15.13 499 234 0.23 / 565.94 3 3
2 7 2003.72 53 14.97 3192 2533 2.77 / 568.47 2 2
3 13 1023.48 16 14.96 1880 450 3.22 / 568.92 2 3
4 13 448.60 16 15.11 1035 250 3.47 / 569.17 2 3
5 13 70.36 16 15.20 467 114 3.58 / 569.29 2 3
6 8 0.20 165 15.18 342 857 4.44 / 570.14 2 6
Average= 4.42
(KJ/cycle)

Cycle 127 GMT 16/ 4/2023 7: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 31 15.12 518 243 0.24 / 561.52 2 3
2 7 2003.68 52 14.97 3207 2496 2.74 / 564.02 2 2
3 13 1033.44 16 14.96 1889 452 3.19 / 564.47 2 3
4 13 477.80 16 15.10 1081 261 3.45 / 564.73 2 3
5 13 46.40 16 15.21 438 107 3.56 / 564.84 2 3
6 8 -0.04 165 15.18 347 869 4.43 / 565.71 2 9
Average= 4.42
(KJ/cycle)

Cycle 126 GMT 6/ 4/2023 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 31 15.12 533 250 0.25 / 557.05 3 3
2 7 2009.24 53 14.96 3221 2554 2.80 / 559.60 2 2
3 13 1029.72 16 14.96 1881 450 3.25 / 560.05 2 3
4 13 483.52 16 15.08 1093 264 3.52 / 560.31 2 3
5 13 45.64 16 15.21 427 104 3.62 / 560.42 2 3
6 8 0.00 165 15.18 343 859 4.48 / 561.28 2 5
Average= 4.42
(KJ/cycle)

Cycle 125 GMT 27/ 3/2023 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 31 15.13 504 236 0.24 / 552.57 3 3
2 7 2003.12 53 14.96 3201 2538 2.77 / 555.11 2 2
3 13 1032.72 16 14.96 1886 451 3.23 / 555.56 2 3
4 13 472.80 16 15.10 1081 261 3.49 / 555.82 2 3
5 13 46.36 16 15.21 434 106 3.59 / 555.93 2 3
6 8 0.04 165 15.19 347 870 4.46 / 556.80 2 7
Average= 4.42
(KJ/cycle)

Cycle 124 GMT 17/ 3/2023 14:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 31 15.11 523 245 0.24 / 548.10 3 3
2 7 2004.84 53 14.97 3215 2551 2.80 / 550.65 2 2
3 13 1040.80 16 14.97 1889 452 3.25 / 551.11 2 3
4 13 466.04 16 15.10 1068 258 3.51 / 551.36 2 3
5 13 46.08 16 15.21 437 106 3.61 / 551.47 2 3
6 8 0.24 165 15.18 345 864 4.48 / 552.33 2 8
Average= 4.42
(KJ/cycle)

Cycle 123 GMT 7/ 3/2023 16:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 31 15.12 530 248 0.25 / 543.60 2 3
2 7 2009.32 53 14.97 3200 2539 2.79 / 546.14 2 2
3 13 1032.44 16 14.97 1878 450 3.24 / 546.59 2 3
4 13 597.36 16 15.06 1246 300 3.54 / 546.89 2 3
5 13 39.40 16 15.21 421 102 3.64 / 546.99 2 3
6 8 0.08 165 15.18 346 867 4.51 / 547.86 2 5
Average= 4.42
(KJ/cycle)

Cycle 122 GMT 25/ 2/2023 19:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 31 15.11 536 251 0.25 / 539.07 2 3
2 7 2007.84 53 14.98 3210 2549 2.80 / 541.62 2 2
3 13 1036.64 16 14.98 1883 451 3.25 / 542.07 2 3
4 13 589.16 16 15.07 1244 300 3.55 / 542.37 2 3
5 13 60.36 16 15.21 461 112 3.66 / 542.48 2 3
6 8 -0.04 165 15.18 348 872 4.53 / 543.35 2 3
Average= 4.42
(KJ/cycle)

Cycle 121 GMT 15/ 2/2023 21:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 31 15.13 532 250 0.25 / 534.61 3 3
2 7 2003.84 53 14.96 3190 2529 2.78 / 537.14 2 2
3 13 1026.32 16 14.97 1867 447 3.23 / 537.59 2 3
4 13 469.60 16 15.11 1064 257 3.48 / 537.84 2 3
5 13 45.00 16 15.22 436 106 3.59 / 537.95 2 2
6 8 0.16 165 15.19 346 867 4.46 / 538.82 2 8
Average= 4.42
(KJ/cycle)

Cycle 120 GMT 6/ 2/2023 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 31 15.14 534 251 0.25 / 530.13 2 3
2 7 2003.52 53 14.99 3208 2549 2.80 / 532.68 2 2
3 13 1036.00 16 14.98 1880 451 3.25 / 533.13 2 3
4 13 472.80 16 15.11 1074 260 3.51 / 533.39 2 3
5 13 36.92 16 15.22 415 101 3.61 / 533.49 2 4
6 8 -0.04 165 15.19 348 872 4.48 / 534.36 2 6
Average= 4.42
(KJ/cycle)

Cycle 119 GMT 27/ 1/2023 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 31 15.13 516 242 0.24 / 525.65 2 3
2 7 2003.36 53 14.98 3204 2544 2.79 / 528.20 2 2
3 13 1016.80 16 14.99 1848 443 3.23 / 528.64 2 3
4 13 458.40 16 15.11 1048 253 3.48 / 528.89 2 3
5 13 35.44 16 15.23 423 103 3.59 / 529.00 2 3
6 8 0.00 165 15.19 352 882 4.47 / 529.88 2 5
Average= 4.42
(KJ/cycle)

Cycle 118 GMT 17/ 1/2023 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 31 15.15 512 240 0.24 / 521.12 3 3
2 7 2007.04 52 14.99 3207 2500 2.74 / 523.62 2 2
3 13 1036.00 16 14.99 1878 450 3.19 / 524.07 2 3
4 13 488.28 16 15.12 1094 265 3.46 / 524.33 2 3
5 13 97.20 16 15.22 507 123 3.58 / 524.45 2 3
6 13 51.64 16 15.22 434 106 3.68 / 524.56 2 3
7 8 0.12 165 15.19 339 850 4.53 / 525.41 2 7
Average= 4.42
(KJ/cycle)

Cycle 117 GMT 7/ 1/2023 7:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 31 15.13 520 244 0.24 / 516.68 2 3
2 7 2004.12 53 14.97 3201 2540 2.78 / 519.22 2 2
3 13 1033.36 16 14.99 1873 449 3.23 / 519.67 2 3
4 13 473.36 16 15.11 1064 257 3.49 / 519.93 2 3
5 13 35.24 16 15.23 409 100 3.59 / 520.03 2 3
6 8 -0.04 165 15.20 337 845 4.43 / 520.88 2 7
Average= 4.41
(KJ/cycle)

Cycle 116 GMT 28/12/2022 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 31 15.13 526 247 0.25 / 512.31 3 3
2 7 2003.24 52 14.96 3191 2482 2.73 / 514.79 2 2
3 13 1030.20 16 14.98 1868 448 3.18 / 515.24 2 3
4 13 462.56 16 15.11 1052 254 3.43 / 515.49 2 2
5 13 38.96 16 15.22 409 100 3.53 / 515.59 2 3
6 8 -0.04 165 15.18 338 847 4.38 / 516.44 2 6
Average= 4.41
(KJ/cycle)

Cycle 115 GMT 18/12/2022 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 31 15.13 523 245 0.25 / 507.88 2 3
2 7 2002.80 53 14.97 3191 2532 2.78 / 510.41 2 2
3 13 1037.80 16 14.97 1882 451 3.23 / 510.86 2 3
4 13 463.00 16 15.11 1058 256 3.48 / 511.12 2 3
5 13 37.92 16 15.22 409 100 3.58 / 511.22 2 3
6 8 0.16 165 15.19 337 845 4.43 / 512.06 2 7
Average= 4.41
(KJ/cycle)

Cycle 114 GMT 8/12/2022 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 31 15.12 528 247 0.25 / 503.40 2 3
2 7 2009.04 53 14.98 3190 2533 2.78 / 505.93 2 2
3 13 1037.24 16 14.99 1883 452 3.23 / 506.38 2 3
4 13 611.68 16 15.08 1264 305 3.54 / 506.69 2 3
5 13 32.68 16 15.23 412 100 3.64 / 506.79 2 3
6 8 -0.12 165 15.19 339 850 4.49 / 507.64 2 7
Average= 4.41
(KJ/cycle)

Cycle 113 GMT 28/11/2022 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 31 15.14 523 245 0.25 / 498.96 2 3
2 7 2006.44 53 14.96 3172 2515 2.76 / 501.47 2 2
3 13 1040.32 16 14.98 1882 451 3.21 / 501.92 2 3
4 13 482.04 16 15.11 1086 263 3.47 / 502.18 2 3
5 13 39.76 16 15.22 420 102 3.58 / 502.29 2 3
6 8 0.08 165 15.19 344 862 4.44 / 503.15 2 7
Average= 4.41
(KJ/cycle)

Cycle 112 GMT 18/11/2022 20:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 31 15.13 530 249 0.25 / 494.60 2 3
2 7 2009.40 53 14.97 3197 2537 2.79 / 497.13 2 2
3 13 1041.48 16 14.97 1893 453 3.24 / 497.59 2 3
4 13 485.76 16 15.10 1092 264 3.50 / 497.85 2 3
5 8 0.20 165 15.20 343 860 4.36 / 498.71 2 7
Average= 4.41
(KJ/cycle)

Cycle 111 GMT 8/11/2022 22:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 31 15.12 536 251 0.25 / 490.13 2 3
2 7 2008.40 53 14.98 3197 2538 2.79 / 492.67 2 2
3 13 1039.72 16 14.97 1881 451 3.24 / 493.12 2 3
4 13 470.76 16 15.11 1068 258 3.50 / 493.38 2 3
5 13 33.96 16 15.22 412 100 3.60 / 493.48 2 3
6 8 0.00 165 15.19 346 867 4.47 / 494.35 2 7
Average= 4.41
(KJ/cycle)

Cycle 110 GMT 30/10/2022 1: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 31 15.14 540 253 0.25 / 485.68 2 3
2 7 2005.88 53 14.98 3195 2537 2.79 / 488.22 2 2
3 13 1035.28 16 14.97 1880 450 3.24 / 488.67 2 3
4 13 462.80 16 15.11 1057 256 3.50 / 488.92 2 3
5 13 15.88 16 15.24 379 92 3.59 / 489.01 2 3
6 8 0.16 165 15.19 346 867 4.46 / 489.88 2 6
Average= 4.41
(KJ/cycle)

Cycle 109 GMT 20/10/2022 3:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 31 15.12 535 251 0.25 / 481.30 2 3
2 7 2005.00 53 14.97 3201 2540 2.79 / 483.84 2 2
3 13 1038.32 16 14.98 1895 454 3.24 / 484.29 2 3
4 13 470.48 16 15.11 1073 259 3.50 / 484.55 2 3
5 8 0.12 165 15.20 350 878 4.38 / 485.43 2 5
Average= 4.41
(KJ/cycle)

Cycle 108 GMT 10/10/2022 6: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 31 15.14 531 249 0.25 / 476.82 2 3
2 7 2011.04 53 14.98 3199 2540 2.79 / 479.36 2 2
3 13 1037.80 16 14.97 1874 449 3.24 / 479.81 2 3
4 13 473.24 16 15.10 1079 261 3.50 / 480.07 2 3
5 13 17.24 16 15.23 389 95 3.59 / 480.16 2 3
6 8 0.08 165 15.19 351 880 4.47 / 481.04 2 7
Average= 4.41
(KJ/cycle)

Cycle 107 GMT 30/ 9/2022 8:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 31 15.15 542 255 0.25 / 472.42 2 3
2 7 2008.72 53 14.98 3217 2554 2.81 / 474.98 2 2
3 13 1009.88 16 14.99 1835 440 3.25 / 475.42 2 3
4 13 571.48 16 15.08 1213 293 3.54 / 475.71 2 3
5 8 0.00 165 15.20 344 863 4.40 / 476.57 2 6
Average= 4.41
(KJ/cycle)

Cycle 106 GMT 20/ 9/2022 11: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 31 15.14 535 251 0.25 / 468.04 2 3
2 7 2003.32 53 14.98 3202 2542 2.79 / 470.59 2 2
3 13 1025.28 16 14.99 1859 446 3.24 / 471.03 2 3
4 13 464.24 16 15.13 1069 259 3.50 / 471.29 2 3
5 8 0.28 165 15.21 349 876 4.37 / 472.17 2 5
Average= 4.41
(KJ/cycle)

Cycle 105 GMT 10/ 9/2022 13:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 31 15.13 533 250 0.25 / 463.52 2 3
2 7 2003.80 53 14.98 3191 2533 2.78 / 466.05 2 2
3 13 1039.68 16 14.98 1880 451 3.23 / 466.50 2 3
4 13 461.20 16 15.12 1055 255 3.49 / 466.76 2 3
5 8 0.08 165 15.21 350 878 4.37 / 467.64 2 5
6 14 0.08 30 15.18 347 158 4.53 / 467.79 2 7
Average= 4.41
(KJ/cycle)

Cycle 104 GMT 31/ 8/2022 16: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 31 15.15 531 249 0.25 / 459.06 2 3
2 7 2008.20 53 14.98 3196 2537 2.79 / 461.60 2 2
3 13 1033.08 16 14.98 1878 450 3.24 / 462.05 2 3
4 13 462.08 16 15.13 1055 255 3.49 / 462.30 2 3
5 13 38.00 16 15.23 414 101 3.59 / 462.41 2 3
6 8 0.08 165 15.20 344 863 4.46 / 463.27 2 6
Average= 4.41
(KJ/cycle)

Cycle 103 GMT 21/ 8/2022 18:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 31 15.15 545 256 0.26 / 454.68 2 3
2 7 2008.00 53 14.98 3209 2548 2.80 / 457.23 2 2
3 13 1032.20 16 15.00 1870 449 3.25 / 457.68 2 3
4 13 451.44 16 15.13 1056 256 3.51 / 457.94 2 3
5 8 0.16 165 15.21 349 876 4.38 / 458.81 2 5
Average= 4.41
(KJ/cycle)

Cycle 102 GMT 11/ 8/2022 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 31 15.14 533 250 0.25 / 450.35 2 3
2 7 2002.64 52 14.99 3191 2487 2.74 / 452.84 2 2
3 13 1020.72 16 15.00 1865 448 3.19 / 453.29 2 3
4 13 448.80 16 15.14 1038 251 3.44 / 453.54 2 3
5 8 0.12 165 15.22 353 886 4.32 / 454.43 2 9
Average= 4.41
(KJ/cycle)

Cycle 101 GMT 1/ 8/2022 23:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 31 15.15 523 246 0.25 / 445.99 2 3
2 7 2005.52 53 14.99 3195 2538 2.78 / 448.52 2 2
3 13 1042.36 16 14.98 1889 453 3.24 / 448.98 2 3
4 13 477.84 16 15.13 1080 261 3.50 / 449.24 2 3
5 8 0.28 165 15.22 345 866 4.36 / 450.10 2 10
Average= 4.41
(KJ/cycle)

Cycle 100 GMT 23/ 7/2022 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 31 15.16 507 238 0.24 / 441.54 3 3
2 7 2006.84 53 14.99 3202 2544 2.78 / 444.08 2 2
3 13 1023.00 16 15.00 1861 447 3.23 / 444.53 2 3
4 13 465.92 16 15.13 1062 257 3.49 / 444.78 2 3
5 13 37.96 16 15.25 416 102 3.59 / 444.89 2 3
6 8 0.12 165 15.22 340 854 4.44 / 445.74 2 4
Average= 4.41
(KJ/cycle)

Cycle 99 GMT 13/ 7/2022 4:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 31 15.16 525 247 0.25 / 437.06 2 3
2 7 2003.52 53 15.00 3189 2535 2.78 / 439.60 2 2
3 13 1163.36 16 14.97 2064 494 3.28 / 440.09 2 3
4 13 447.88 16 15.14 1028 249 3.53 / 440.34 2 3
5 13 43.08 16 15.25 425 104 3.63 / 440.44 2 3
6 8 -0.04 165 15.22 341 856 4.49 / 441.30 2 4
Average= 4.41
(KJ/cycle)

Cycle 98 GMT 3/ 7/2022 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 15.15 507 238 0.24 / 432.65 2 3
2 7 2002.80 52 14.99 3196 2491 2.73 / 435.14 2 2
3 13 1025.60 16 15.00 1868 448 3.18 / 435.59 2 3
4 13 468.80 16 15.12 1066 258 3.44 / 435.85 2 3
5 13 39.04 16 15.25 416 102 3.54 / 435.95 2 2
6 8 0.24 165 15.22 343 861 4.40 / 436.81 2 4
Average= 4.41
(KJ/cycle)

Cycle 97 GMT 23/ 6/2022 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 31 15.16 531 250 0.25 / 428.15 2 3
2 7 2005.52 53 14.98 3190 2533 2.78 / 430.69 2 2
3 13 1032.24 16 14.99 1878 450 3.23 / 431.14 2 3
4 13 586.12 16 15.10 1236 299 3.53 / 431.44 2 3
5 13 54.92 16 15.25 449 110 3.64 / 431.55 2 3
6 8 -0.12 165 15.22 346 869 4.51 / 432.42 2 6
Average= 4.41
(KJ/cycle)

Cycle 96 GMT 13/ 6/2022 11:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 31 15.17 514 242 0.24 / 423.70 2 3
2 7 2009.60 53 15.01 3197 2543 2.79 / 426.24 2 2
3 13 1025.96 16 15.00 1867 448 3.23 / 426.69 2 3
4 13 452.04 16 15.15 1044 253 3.49 / 426.94 2 3
5 13 35.44 16 15.25 413 101 3.59 / 427.04 2 3
6 8 0.00 165 15.23 344 864 4.45 / 427.91 2 5
Average= 4.41
(KJ/cycle)

Cycle 95 GMT 3/ 6/2022 14: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 31 15.16 520 244 0.24 / 419.24 2 3
2 7 2008.52 53 15.00 3210 2552 2.80 / 421.79 2 2
3 13 1018.68 16 15.02 1859 447 3.24 / 422.24 2 3
4 13 458.76 16 15.15 1049 254 3.50 / 422.49 2 3
5 13 35.72 16 15.26 412 101 3.60 / 422.59 2 3
6 8 0.12 165 15.22 344 864 4.46 / 423.45 2 10
Average= 4.41
(KJ/cycle)

Cycle 94 GMT 24/ 5/2022 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 31 15.18 525 247 0.25 / 414.64 2 3
2 7 2005.64 53 14.99 3181 2527 2.77 / 417.17 2 2
3 13 1030.12 16 15.01 1865 448 3.22 / 417.62 2 3
4 13 465.88 16 15.14 1059 257 3.48 / 417.87 2 3
5 13 40.96 16 15.26 421 103 3.58 / 417.97 2 3
6 8 0.04 165 15.22 343 861 4.44 / 418.84 2 11
7 14 0.04 30 15.20 342 156 4.60 / 418.99 2 8
Average= 4.41
(KJ/cycle)

Cycle 93 GMT 14/ 5/2022 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 31 15.15 528 248 0.25 / 410.16 2 3
2 7 2005.56 53 14.99 3193 2537 2.78 / 412.70 2 2
3 13 1031.92 16 15.01 1881 452 3.24 / 413.15 2 3
4 13 462.16 16 15.15 1058 256 3.49 / 413.41 2 3
5 13 74.44 16 15.25 479 117 3.61 / 413.52 2 3
6 8 0.00 165 15.23 346 869 4.48 / 414.39 2 8
Average= 4.41
(KJ/cycle)

Cycle 92 GMT 4/ 5/2022 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 31 15.16 531 250 0.25 / 405.49 2 3
2 7 2004.64 53 14.99 3209 2549 2.80 / 408.04 2 2
3 13 1029.32 16 15.01 1871 449 3.25 / 408.49 2 3
4 13 465.88 16 15.15 1064 258 3.51 / 408.75 2 3
5 13 73.80 16 15.25 483 118 3.62 / 408.87 2 2
6 8 0.04 165 15.23 353 887 4.51 / 409.75 2 4
7 14 0.04 30 15.21 354 162 4.67 / 409.91 2 9
Average= 4.41
(KJ/cycle)

Cycle 91 GMT 25/ 4/2022 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 31 15.17 533 251 0.25 / 400.99 3 3
2 7 2010.36 53 15.01 3203 2548 2.80 / 403.54 2 2
3 13 1038.04 16 15.02 1895 455 3.25 / 403.99 2 3
4 13 471.96 16 15.14 1079 261 3.52 / 404.25 2 3
5 13 44.36 16 15.26 433 106 3.62 / 404.36 2 3
6 8 0.00 165 15.23 351 882 4.50 / 405.24 2 7
Average= 4.40
(KJ/cycle)

Cycle 90 GMT 15/ 4/2022 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 31 15.17 526 247 0.25 / 396.50 2 3
2 7 2004.60 53 14.99 3201 2543 2.79 / 399.05 2 2
3 13 1027.84 16 15.01 1866 448 3.24 / 399.50 2 3
4 13 471.04 16 15.14 1068 259 3.50 / 399.75 2 3
5 13 46.68 16 15.26 439 107 3.60 / 399.86 2 3
6 8 0.08 165 15.23 349 877 4.48 / 400.74 2 6
Average= 4.40
(KJ/cycle)

Cycle 89 GMT 5/ 4/2022 4:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 31 15.18 528 248 0.25 / 392.03 2 3
2 7 2005.24 53 14.99 3199 2542 2.79 / 394.57 2 2
3 13 1023.68 16 15.02 1873 450 3.24 / 395.02 2 3
4 13 448.36 16 15.16 1043 253 3.49 / 395.28 2 3
5 13 63.52 16 15.25 466 114 3.61 / 395.39 2 3
6 8 0.16 165 15.23 345 867 4.47 / 396.26 2 7
Average= 4.40
(KJ/cycle)

Cycle 88 GMT 26/ 3/2022 7:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 31 15.18 525 247 0.25 / 387.55 2 3
2 7 2009.52 53 15.00 3198 2542 2.79 / 390.09 2 2
3 13 1014.96 16 15.03 1859 447 3.24 / 390.54 2 3
4 13 451.04 16 15.15 1041 252 3.49 / 390.79 2 3
5 13 69.88 16 15.26 477 116 3.61 / 390.91 2 3
6 8 0.00 165 15.23 349 877 4.48 / 391.78 2 5
Average= 4.40
(KJ/cycle)

Cycle 87 GMT 16/ 3/2022 9:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 31 15.19 520 245 0.24 / 383.08 2 3
2 7 2003.40 53 15.01 3189 2537 2.78 / 385.62 2 2
3 13 1020.48 16 15.02 1855 446 3.23 / 386.06 2 3
4 13 461.60 16 15.15 1065 258 3.49 / 386.32 2 3
5 13 71.60 16 15.26 472 115 3.60 / 386.44 2 3
6 8 0.00 165 15.24 344 865 4.47 / 387.30 2 6
Average= 4.40
(KJ/cycle)

Cycle 86 GMT 6/ 3/2022 12:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 31 15.19 534 251 0.25 / 378.61 3 3
2 7 2003.64 53 15.01 3192 2539 2.79 / 381.15 2 2
3 13 1028.68 16 15.03 1881 452 3.24 / 381.60 2 3
4 13 464.36 16 15.15 1062 257 3.50 / 381.86 2 3
5 13 36.32 16 15.29 421 103 3.60 / 381.96 2 3
6 8 0.36 165 15.25 347 873 4.48 / 382.83 2 7
Average= 4.40
(KJ/cycle)

Cycle 85 GMT 24/ 2/2022 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 31 15.19 519 244 0.24 / 374.18 3 3
2 7 2003.36 52 15.02 3192 2493 2.74 / 376.67 2 2
3 13 1018.44 16 15.04 1858 447 3.18 / 377.12 2 3
4 13 448.68 16 15.17 1045 254 3.44 / 377.37 2 3
5 13 39.52 16 15.29 424 104 3.54 / 377.48 2 3
6 8 0.00 165 15.26 350 881 4.42 / 378.36 3 5
Average= 4.40
(KJ/cycle)

Cycle 84 GMT 14/ 2/2022 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 31 15.19 529 249 0.25 / 369.71 3 3
2 7 2005.88 53 15.01 3182 2531 2.78 / 372.24 2 2
3 13 1024.76 16 15.03 1874 451 3.23 / 372.69 2 3
4 13 455.48 16 15.17 1054 256 3.49 / 372.95 2 3
5 13 70.48 16 15.27 477 117 3.60 / 373.07 2 3
6 8 -0.08 165 15.25 345 868 4.47 / 373.93 2 5
Average= 4.40
(KJ/cycle)

Cycle 83 GMT 4/ 2/2022 19:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 31 15.20 523 246 0.25 / 365.28 3 3
2 7 2009.96 52 15.02 3208 2506 2.75 / 367.79 2 2
3 13 1023.12 16 15.03 1867 449 3.20 / 368.24 2 3
4 13 451.80 16 15.18 1043 253 3.45 / 368.49 2 3
5 13 35.32 16 15.28 419 102 3.56 / 368.59 2 3
6 8 0.20 165 15.26 346 871 4.43 / 369.46 3 7
Average= 4.40
(KJ/cycle)

Cycle 82 GMT 25/ 1/2022 22: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 31 15.19 524 247 0.25 / 360.63 3 3
2 7 2006.08 53 15.01 3216 2558 2.81 / 363.19 2 2
3 13 1027.92 16 15.04 1886 454 3.26 / 363.65 2 3
4 13 450.20 16 15.18 1045 254 3.51 / 363.90 2 3
5 13 37.48 16 15.29 424 104 3.62 / 364.00 2 3
6 8 -0.04 165 15.26 347 874 4.49 / 364.88 2 4
7 14 -0.04 30 15.23 345 158 4.65 / 365.04 3 10
Average= 4.40
(KJ/cycle)

Cycle 81 GMT 16/ 1/2022 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 31 15.20 526 248 0.25 / 356.15 2 3
2 7 2002.60 53 15.03 3205 2553 2.80 / 358.70 2 2
3 13 1008.84 16 15.04 1855 446 3.25 / 359.15 2 3
4 13 448.08 16 15.19 1047 254 3.50 / 359.40 2 3
5 13 33.20 16 15.30 420 103 3.60 / 359.50 2 3
6 8 0.24 165 15.26 351 884 4.49 / 360.39 2 7
Average= 4.39
(KJ/cycle)

Cycle 80 GMT 6/ 1/2022 2:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 31 15.20 530 250 0.25 / 351.67 2 3
2 7 2010.76 52 15.02 3231 2524 2.77 / 354.19 2 2
3 13 1034.84 16 15.03 1894 455 3.23 / 354.64 2 3
4 13 473.08 16 15.18 1095 266 3.49 / 354.91 2 3
5 13 40.32 16 15.30 427 105 3.60 / 355.01 2 3
6 8 0.12 165 15.26 351 884 4.48 / 355.90 2 8
Average= 4.39
(KJ/cycle)

Cycle 79 GMT 27/12/2021 5:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 31 15.22 521 246 0.25 / 347.19 3 3
2 7 2009.56 53 15.03 3192 2543 2.79 / 349.74 2 2
3 13 1011.12 16 15.05 1857 447 3.24 / 350.18 2 3
4 13 438.64 16 15.19 1035 252 3.49 / 350.43 2 3
5 13 27.80 16 15.30 409 100 3.59 / 350.53 2 3
6 8 0.08 165 15.27 350 882 4.47 / 351.42 2 6
Average= 4.39
(KJ/cycle)

Cycle 78 GMT 17/12/2021 7:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 31 15.22 533 251 0.25 / 342.75 2 3
2 7 2008.68 52 15.03 3205 2505 2.76 / 345.25 2 2
3 13 1025.40 16 15.05 1881 453 3.21 / 345.70 2 3
4 13 457.76 16 15.18 1064 258 3.47 / 345.96 2 3
5 13 33.84 16 15.30 414 101 3.57 / 346.06 2 3
6 8 -0.04 165 15.28 350 882 4.45 / 346.95 2 5
Average= 4.39
(KJ/cycle)

Cycle 77 GMT 7/12/2021 10:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 31 15.21 537 253 0.25 / 338.18 3 3
2 7 2010.80 53 15.03 3218 2563 2.82 / 340.74 2 2
3 13 1021.68 16 15.05 1883 453 3.27 / 341.20 2 3
4 13 443.48 16 15.20 1039 253 3.52 / 341.45 2 3
5 8 0.28 165 15.28 351 885 4.41 / 342.33 2 5
6 14 0.28 30 15.26 350 160 4.57 / 342.50 2 8
Average= 4.39
(KJ/cycle)

Cycle 76 GMT 27/11/2021 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 31 15.22 534 252 0.25 / 333.80 2 3
2 7 2002.52 53 15.01 3190 2538 2.79 / 336.34 2 2
3 13 1021.68 16 15.05 1871 451 3.24 / 336.79 2 3
4 13 439.12 16 15.19 1038 252 3.49 / 337.04 2 3
5 8 0.04 165 15.28 352 887 4.38 / 337.93 2 6
Average= 4.39
(KJ/cycle)

Cycle 75 GMT 17/11/2021 15: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 15.25 528 242 0.24 / 329.28 2 3
2 7 2011.64 53 15.04 3212 2560 2.80 / 331.84 2 2
3 13 1031.20 16 15.05 1891 455 3.26 / 332.29 2 3
4 13 461.20 16 15.21 1064 259 3.52 / 332.55 2 3
5 13 33.44 16 15.32 414 101 3.62 / 332.65 2 2
6 8 0.00 165 15.28 355 895 4.51 / 333.55 2 8
Average= 4.39
(KJ/cycle)

Cycle 74 GMT 7/11/2021 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 30 15.24 538 246 0.25 / 324.79 2 3
2 7 2005.64 53 15.04 3186 2540 2.79 / 327.33 2 2
3 13 1017.60 16 15.07 1862 449 3.23 / 327.77 2 3
4 13 453.60 16 15.21 1050 256 3.49 / 328.03 2 3
5 13 33.48 16 15.33 421 103 3.59 / 328.13 2 3
6 8 0.08 165 15.29 357 901 4.49 / 329.03 2 6
Average= 4.39
(KJ/cycle)

Cycle 73 GMT 28/10/2021 20: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 30 15.25 540 247 0.25 / 320.37 2 3
2 7 2009.88 53 15.04 3208 2557 2.80 / 322.93 2 2
3 13 1030.92 16 15.05 1886 454 3.26 / 323.38 2 3
4 13 463.52 16 15.20 1068 260 3.52 / 323.64 2 3
5 8 0.00 165 15.30 357 901 4.42 / 324.54 2 5
Average= 4.39
(KJ/cycle)

Cycle 72 GMT 18/10/2021 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 30 15.25 536 245 0.25 / 315.86 2 3
2 7 2004.08 53 15.04 3204 2554 2.80 / 318.41 2 2
3 13 1015.64 16 15.07 1859 448 3.25 / 318.86 2 3
4 13 455.16 16 15.23 1062 259 3.51 / 319.12 2 3
5 13 30.72 16 15.35 416 102 3.61 / 319.22 2 3
6 8 0.16 165 15.32 355 897 4.51 / 320.12 2 5
Average= 4.39
(KJ/cycle)

Cycle 71 GMT 9/10/2021 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 30 15.27 536 246 0.25 / 311.19 2 3
2 7 2003.04 53 15.06 3202 2556 2.80 / 313.75 2 2
3 13 1007.96 16 15.09 1858 449 3.25 / 314.20 2 3
4 13 440.28 16 15.23 1042 254 3.50 / 314.45 2 3
5 13 30.60 16 15.35 420 103 3.61 / 314.55 2 3
6 8 0.20 165 15.32 356 900 4.51 / 315.45 2 11
7 14 0.20 30 15.29 354 162 4.67 / 315.62 2 8
Average= 4.38
(KJ/cycle)

Cycle 70 GMT 29/ 9/2021 3:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 30 15.26 541 248 0.25 / 306.83 2 3
2 7 2010.12 53 15.05 3213 2563 2.81 / 309.39 2 2
3 13 1017.76 16 15.08 1874 452 3.26 / 309.84 2 3
4 13 318.88 16 15.28 859 210 3.47 / 310.05 2 3
5 8 0.20 165 15.33 353 893 4.37 / 310.95 2 6
Average= 4.38
(KJ/cycle)

Cycle 69 GMT 19/ 9/2021 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 30 15.28 542 248 0.25 / 302.42 2 3
2 7 2002.92 53 15.04 3209 2558 2.81 / 304.98 2 2
3 13 1017.08 16 15.08 1871 451 3.26 / 305.43 2 3
4 13 448.32 16 15.24 1051 256 3.51 / 305.68 2 3
5 8 0.04 165 15.32 355 897 4.41 / 306.58 2 6
Average= 4.38
(KJ/cycle)

Cycle 68 GMT 9/ 9/2021 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 15.28 538 247 0.25 / 297.98 3 3
2 7 2004.72 53 15.06 3217 2568 2.81 / 300.55 2 2
3 13 1014.52 16 15.10 1870 452 3.27 / 301.00 2 3
4 13 440.08 16 15.25 1042 254 3.52 / 301.26 2 3
5 8 0.24 165 15.34 360 911 4.43 / 302.17 2 7
Average= 4.38
(KJ/cycle)

Cycle 67 GMT 30/ 8/2021 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 30 15.28 549 252 0.25 / 293.57 2 3
2 7 2008.44 52 15.06 3216 2519 2.77 / 296.09 2 2
3 13 1014.36 16 15.11 1866 451 3.22 / 296.54 2 3
4 13 574.20 16 15.22 1239 302 3.52 / 296.84 2 3
5 8 0.08 165 15.34 354 896 4.42 / 297.74 2 8
Average= 4.38
(KJ/cycle)

Cycle 66 GMT 20/ 8/2021 13:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 30 15.29 547 251 0.25 / 289.15 2 3
2 7 2008.56 53 15.06 3214 2565 2.82 / 291.72 2 2
3 13 1004.16 16 15.10 1826 441 3.26 / 292.16 2 3
4 13 437.56 16 15.27 1024 250 3.51 / 292.41 2 3
5 8 0.36 165 15.35 360 912 4.42 / 293.32 2 10
Average= 4.38
(KJ/cycle)

Cycle 65 GMT 10/ 8/2021 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 30 15.29 523 240 0.24 / 284.46 2 3
2 7 2007.08 53 15.06 3192 2548 2.79 / 287.01 2 2
3 13 1009.36 16 15.10 1852 447 3.24 / 287.46 2 3
4 13 446.48 16 15.26 1054 257 3.49 / 287.71 2 3
5 13 68.44 16 15.36 479 118 3.61 / 287.83 2 3
6 8 -0.12 165 15.34 357 904 4.51 / 288.73 2 4
7 14 -0.12 30 15.32 357 164 4.68 / 288.90 2 7
Average= 4.38
(KJ/cycle)

Cycle 64 GMT 31/ 7/2021 18: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 30 15.31 540 248 0.25 / 279.95 2 3
2 7 2007.04 53 15.06 3201 2555 2.80 / 282.51 2 2
3 13 1013.16 16 15.10 1853 448 3.25 / 282.96 2 3
4 13 443.60 16 15.27 1041 254 3.51 / 283.21 2 3
5 13 63.64 16 15.38 465 114 3.62 / 283.32 2 3
6 8 0.16 165 15.35 354 897 4.52 / 284.22 2 6
Average= 4.37
(KJ/cycle)

Cycle 63 GMT 21/ 7/2021 20:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 30 15.29 535 245 0.25 / 275.58 2 3
2 7 2007.72 52 15.07 3216 2520 2.77 / 278.10 2 2
3 13 1014.72 16 15.12 1870 452 3.22 / 278.55 2 3
4 13 432.08 16 15.27 1032 252 3.47 / 278.81 2 3
5 8 0.12 165 15.36 355 900 4.37 / 279.71 2 5
Average= 4.37
(KJ/cycle)

Cycle 62 GMT 11/ 7/2021 22:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 15.29 547 251 0.25 / 271.01 2 3
2 7 2004.72 53 15.06 3211 2563 2.81 / 273.57 2 2
3 13 1009.00 16 15.11 1858 449 3.26 / 274.02 2 3
4 13 445.96 16 15.27 1046 256 3.52 / 274.27 2 3
5 8 0.04 165 15.36 354 897 4.42 / 275.17 2 8
6 14 0.04 30 15.34 355 163 4.58 / 275.34 2 5
Average= 4.37
(KJ/cycle)

Cycle 61 GMT 2/ 7/2021 1:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 30 15.29 538 247 0.25 / 266.47 2 3
2 7 2003.00 53 15.06 3208 2561 2.81 / 269.03 2 2
3 13 1015.08 16 15.11 1873 453 3.26 / 269.49 2 3
4 13 434.20 16 15.28 1016 248 3.51 / 269.74 2 3
5 13 62.56 16 15.38 474 117 3.63 / 269.85 2 2
6 8 0.16 165 15.35 357 904 4.53 / 270.76 2 6
Average= 4.37
(KJ/cycle)

Cycle 60 GMT 22/ 6/2021 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 30 15.30 526 241 0.24 / 261.95 2 3
2 7 2007.36 53 15.06 3202 2556 2.80 / 264.50 2 2
3 13 1027.40 16 15.11 1885 456 3.25 / 264.96 2 3
4 13 453.28 16 15.27 1063 260 3.51 / 265.22 2 3
5 13 32.12 16 15.38 423 104 3.62 / 265.32 2 2
6 8 0.32 165 15.35 357 904 4.52 / 266.23 2 6
Average= 4.36
(KJ/cycle)

Cycle 59 GMT 12/ 6/2021 6:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 30 15.30 546 251 0.25 / 257.40 2 3
2 7 2009.44 53 15.06 3212 2564 2.81 / 259.97 2 2
3 13 1012.68 16 15.12 1862 450 3.26 / 260.42 2 3
4 13 447.00 16 15.27 1054 258 3.52 / 260.68 2 3
5 13 65.28 16 15.39 471 116 3.64 / 260.79 2 3
6 8 0.16 165 15.35 361 914 4.55 / 261.71 2 7
Average= 4.36
(KJ/cycle)

Cycle 58 GMT 2/ 6/2021 8:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 30 15.30 524 241 0.24 / 252.83 2 3
2 7 2002.96 53 15.08 3200 2558 2.80 / 255.39 2 2
3 13 1016.76 16 15.12 1858 449 3.25 / 255.84 2 3
4 13 574.76 16 15.25 1238 302 3.55 / 256.14 2 3
5 13 50.68 16 15.39 444 109 3.66 / 256.25 2 2
6 8 0.20 165 15.36 355 900 4.56 / 257.15 2 4
Average= 4.36
(KJ/cycle)

Cycle 57 GMT 23/ 5/2021 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 30 15.31 532 244 0.24 / 248.18 2 3
2 7 2005.88 52 15.08 3208 2516 2.76 / 250.70 2 2
3 13 1016.60 16 15.13 1868 452 3.21 / 251.15 2 3
4 13 435.52 16 15.29 1031 252 3.46 / 251.40 2 3
5 13 62.16 16 15.38 476 117 3.58 / 251.52 2 3
6 8 -0.20 165 15.36 359 910 4.49 / 252.43 2 5
7 14 -0.20 30 15.34 358 165 4.66 / 252.59 2 6
Average= 4.36
(KJ/cycle)

Cycle 56 GMT 13/ 5/2021 13:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 30 15.31 542 249 0.25 / 243.66 2 3
2 7 2003.44 53 15.07 3210 2564 2.81 / 246.22 2 2
3 13 1011.04 16 15.13 1866 452 3.26 / 246.67 2 3
4 13 429.72 16 15.29 1028 251 3.52 / 246.93 2 3
5 13 59.64 16 15.40 468 115 3.63 / 247.04 2 2
6 8 0.32 165 15.37 354 898 4.53 / 247.94 2 7
Average= 4.35
(KJ/cycle)

Cycle 55 GMT 3/ 5/2021 16:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 15.31 543 249 0.25 / 239.08 2 3
2 7 2003.80 52 15.08 3203 2512 2.76 / 241.59 2 2
3 13 1014.80 16 15.13 1869 452 3.21 / 242.04 2 3
4 13 440.88 16 15.30 1034 253 3.47 / 242.29 2 3
5 13 60.84 16 15.40 468 115 3.58 / 242.41 2 3
6 13 15.32 16 15.41 391 96 3.68 / 242.51 2 3
7 8 -0.04 165 15.37 356 903 4.58 / 243.41 2 6
Average= 4.35
(KJ/cycle)

Cycle 54 GMT 23/ 4/2021 18:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 30 15.32 520 239 0.24 / 234.61 2 3
2 7 2011.20 52 15.07 3210 2515 2.75 / 237.12 2 2
3 13 1007.40 16 15.14 1854 449 3.20 / 237.57 2 3
4 13 438.08 16 15.29 1028 251 3.46 / 237.82 2 3
5 13 37.76 16 15.41 424 105 3.56 / 237.93 2 3
6 8 0.24 165 15.37 355 900 4.46 / 238.83 2 10
Average= 4.34
(KJ/cycle)

Cycle 53 GMT 13/ 4/2021 21:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 30 15.32 523 240 0.24 / 230.10 2 3
2 7 2011.60 53 15.07 3212 2565 2.81 / 232.67 2 2
3 13 901.24 16 15.17 1700 413 3.22 / 233.08 2 3
4 13 625.40 16 15.23 1288 314 3.53 / 233.39 2 3
5 13 38.28 16 15.41 417 103 3.64 / 233.50 2 3
6 8 0.04 165 15.37 344 872 4.51 / 234.37 2 8
Average= 4.34
(KJ/cycle)

Cycle 52 GMT 3/ 4/2021 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 30 15.32 537 247 0.25 / 225.45 2 3
2 7 2003.00 53 15.08 3194 2553 2.80 / 228.00 2 2
3 13 1018.68 16 15.13 1869 452 3.25 / 228.45 2 3
4 13 431.16 16 15.29 1023 250 3.50 / 228.70 2 3
5 13 38.84 16 15.41 429 106 3.61 / 228.81 2 3
6 8 0.04 165 15.38 351 891 4.50 / 229.70 2 8
7 14 0.04 30 15.36 349 161 4.66 / 229.86 2 7
Average= 4.34
(KJ/cycle)

Cycle 51 GMT 25/ 3/2021 2:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 30 15.33 517 238 0.24 / 221.01 2 3
2 7 2004.20 52 15.09 3208 2517 2.76 / 223.53 2 2
3 13 899.12 16 15.18 1697 412 3.17 / 223.94 2 3
4 13 472.96 16 15.29 1080 264 3.43 / 224.21 2 3
5 13 41.00 16 15.41 426 105 3.54 / 224.31 2 3
6 8 0.00 165 15.38 350 888 4.42 / 225.20 2 4
Average= 4.33
(KJ/cycle)

Cycle 50 GMT 15/ 3/2021 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 15.35 516 238 0.24 / 216.36 2 3
2 7 2009.84 53 15.09 3208 2566 2.80 / 218.93 2 2
3 13 1007.76 16 15.15 1862 451 3.25 / 219.38 2 3
4 13 432.64 16 15.32 1020 250 3.50 / 219.63 2 2
5 13 35.12 16 15.42 422 104 3.61 / 219.73 2 3
6 8 0.12 165 15.38 348 883 4.49 / 220.62 2 4
7 14 0.12 30 15.36 344 159 4.65 / 220.78 2 6
Average= 4.33
(KJ/cycle)

Cycle 49 GMT 5/ 3/2021 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 30 15.34 534 246 0.25 / 211.88 2 3
2 7 2002.84 53 15.10 3199 2560 2.81 / 214.44 2 2
3 13 1015.92 16 15.15 1871 454 3.26 / 214.89 2 3
4 13 437.20 16 15.31 1029 252 3.51 / 215.14 2 3
5 13 36.52 16 15.43 424 105 3.62 / 215.25 2 3
6 8 0.12 165 15.40 346 879 4.50 / 216.13 2 6
Average= 4.32
(KJ/cycle)

Cycle 48 GMT 23/ 2/2021 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 30 15.35 532 245 0.24 / 207.36 2 3
2 7 2011.24 53 15.09 3210 2567 2.81 / 209.93 2 2
3 13 1016.20 16 15.17 1856 450 3.26 / 210.38 2 3
4 13 433.32 16 15.32 1029 252 3.51 / 210.63 2 3
5 13 35.24 16 15.42 429 106 3.62 / 210.74 2 3
6 8 0.20 165 15.40 352 894 4.52 / 211.63 2 5
Average= 4.32
(KJ/cycle)

Cycle 47 GMT 13/ 2/2021 12: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 30 15.34 516 237 0.24 / 202.88 2 3
2 7 2006.64 52 15.10 3206 2517 2.75 / 205.40 2 2
3 13 1023.48 16 15.15 1869 453 3.21 / 205.85 2 3
4 13 441.04 16 15.31 1041 255 3.46 / 206.11 2 3
5 13 30.88 16 15.42 421 104 3.57 / 206.21 2 3
6 8 0.04 165 15.40 355 902 4.47 / 207.12 2 4
Average= 4.31
(KJ/cycle)

Cycle 46 GMT 3/ 2/2021 14:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 30 15.35 519 239 0.24 / 198.40 2 3
2 7 2009.84 53 15.10 3210 2569 2.81 / 200.97 2 2
3 13 1009.32 16 15.17 1851 449 3.26 / 201.42 2 3
4 13 425.68 16 15.33 1012 248 3.51 / 201.67 2 3
5 13 29.52 16 15.44 413 102 3.61 / 201.77 2 3
6 8 0.16 165 15.41 344 875 4.48 / 202.65 2 6
Average= 4.31
(KJ/cycle)

Cycle 45 GMT 24/ 1/2021 16:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 30 15.38 503 232 0.23 / 193.98 2 3
2 7 2003.00 53 15.11 3195 2559 2.79 / 196.54 2 2
3 13 997.16 16 15.18 1824 443 3.23 / 196.98 2 3
4 13 412.44 16 15.33 981 241 3.47 / 197.22 2 3
5 13 26.80 16 15.44 397 98 3.57 / 197.32 2 2
6 8 -0.08 165 15.42 332 845 4.42 / 198.16 2 5
Average= 4.31
(KJ/cycle)

Cycle 44 GMT 14/ 1/2021 19:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 30 15.36 504 232 0.23 / 189.59 2 3
2 7 2007.96 53 15.10 3206 2566 2.80 / 192.16 2 2
3 13 992.32 16 15.19 1801 438 3.24 / 192.59 2 3
4 13 420.72 16 15.34 984 242 3.48 / 192.84 2 3
5 13 28.84 16 15.46 384 95 3.57 / 192.93 2 2
6 8 -0.08 165 15.42 321 817 4.39 / 193.75 2 7
Average= 4.31
(KJ/cycle)

Cycle 43 GMT 4/ 1/2021 21:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 30 15.36 517 238 0.24 / 185.02 2 3
2 7 2012.64 53 15.09 3212 2569 2.81 / 187.59 2 2
3 13 1009.60 16 15.18 1826 443 3.25 / 188.04 2 3
4 13 441.40 16 15.33 1014 249 3.50 / 188.28 2 3
5 13 29.80 16 15.44 389 96 3.60 / 188.38 2 3
6 8 0.28 165 15.42 325 827 4.42 / 189.21 2 9
7 14 0.28 30 15.40 326 151 4.57 / 189.36 2 8
Average= 4.30
(KJ/cycle)

Cycle 42 GMT 26/12/2020 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 30 15.38 510 235 0.24 / 180.62 2 3
2 7 2007.24 52 15.10 3199 2512 2.75 / 183.13 2 2
3 13 1016.40 16 15.17 1866 453 3.20 / 183.58 2 3
4 13 427.80 16 15.34 1010 248 3.45 / 183.83 2 3
5 13 26.76 16 15.45 399 99 3.55 / 183.93 2 3
6 8 -0.04 165 15.42 337 857 4.40 / 184.79 2 6
Average= 4.30
(KJ/cycle)

Cycle 41 GMT 16/12/2020 2:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 30 15.37 519 239 0.24 / 176.18 2 3
2 7 2008.24 53 15.11 3198 2561 2.80 / 178.74 2 2
3 13 1011.84 16 15.18 1856 451 3.25 / 179.19 2 3
4 13 433.56 16 15.34 1019 250 3.50 / 179.44 2 3
5 13 26.08 16 15.46 394 97 3.60 / 179.54 2 3
6 8 -0.12 165 15.43 330 840 4.44 / 180.38 2 10
Average= 4.29
(KJ/cycle)

Cycle 40 GMT 6/12/2020 5: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 30 15.37 520 240 0.24 / 171.72 2 3
2 7 2008.28 53 15.11 3204 2566 2.81 / 174.29 2 2
3 13 1015.92 16 15.18 1855 451 3.26 / 174.74 2 3
4 13 442.96 16 15.34 1030 253 3.51 / 174.99 2 3
5 13 26.72 16 15.46 395 98 3.61 / 175.09 2 3
6 8 0.32 165 15.42 336 855 4.46 / 175.94 2 8
Average= 4.29
(KJ/cycle)

Cycle 39 GMT 26/11/2020 7:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 29 15.38 510 227 0.23 / 167.38 2 3
2 7 2011.36 53 15.10 3214 2572 2.80 / 169.95 2 2
3 13 1006.52 16 15.18 1835 446 3.25 / 170.40 2 3
4 13 424.40 16 15.35 1003 246 3.49 / 170.64 2 3
5 8 -0.08 165 15.44 329 838 4.33 / 171.48 2 9
Average= 4.29
(KJ/cycle)

Cycle 38 GMT 16/11/2020 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 29 15.37 526 234 0.23 / 162.94 2 3
2 7 2005.76 53 15.11 3182 2548 2.78 / 165.49 2 2
3 13 988.32 16 15.20 1804 439 3.22 / 165.93 2 3
4 13 403.52 16 15.35 954 234 3.46 / 166.16 2 3
5 8 -0.12 165 15.44 329 838 4.29 / 167.00 2 7
6 14 -0.12 30 15.42 327 151 4.45 / 167.15 2 8
Average= 4.29
(KJ/cycle)

Cycle 37 GMT 6/11/2020 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 29 15.38 525 234 0.23 / 158.56 2 3
2 7 2006.24 53 15.11 3204 2566 2.80 / 161.12 2 2
3 13 1027.08 16 15.18 1875 455 3.26 / 161.58 2 2
4 13 434.64 16 15.34 1029 253 3.51 / 161.83 2 3
5 8 0.32 165 15.43 343 873 4.38 / 162.71 2 9
Average= 4.28
(KJ/cycle)

Cycle 36 GMT 27/10/2020 14:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 29 15.39 515 230 0.23 / 154.08 2 3
2 7 2004.00 53 15.11 3214 2574 2.80 / 156.66 2 2
3 13 1011.64 16 15.20 1852 450 3.25 / 157.11 2 2
4 13 444.76 16 15.34 1035 254 3.51 / 157.36 2 3
5 13 14.60 16 15.45 385 95 3.60 / 157.46 2 3
6 8 -0.04 165 15.43 341 868 4.47 / 158.32 2 5
Average= 4.28
(KJ/cycle)

Cycle 35 GMT 17/10/2020 17:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 15.40 507 226 0.23 / 149.83 2 3
2 7 2003.52 52 15.12 3214 2527 2.75 / 152.36 2 2
3 13 1010.84 16 15.19 1850 450 3.20 / 152.81 2 3
4 13 305.68 16 15.39 832 205 3.41 / 153.01 2 3
5 8 0.12 165 15.44 331 843 4.25 / 153.85 2 7
Average= 4.27
(KJ/cycle)

Cycle 34 GMT 7/10/2020 19:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 29 15.40 521 233 0.23 / 145.51 2 3
2 7 2010.12 53 15.13 3216 2579 2.81 / 148.08 2 2
3 13 1008.64 16 15.21 1827 445 3.26 / 148.53 2 3
4 13 426.60 16 15.36 1001 246 3.50 / 148.78 2 3
5 8 0.16 165 15.46 324 826 4.33 / 149.60 2 6
Average= 4.27
(KJ/cycle)

Cycle 33 GMT 27/ 9/2020 22:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 29 15.38 525 234 0.23 / 141.18 2 3
2 7 2007.96 52 15.13 3221 2534 2.77 / 143.72 2 2
3 13 993.52 16 15.21 1828 445 3.21 / 144.16 2 3
4 13 415.92 16 15.37 993 244 3.46 / 144.40 2 3
5 8 0.12 165 15.45 341 869 4.33 / 145.27 2 8
Average= 4.27
(KJ/cycle)

Cycle 32 GMT 18/ 9/2020 0:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 29 15.40 517 231 0.23 / 136.79 2 3
2 7 2006.36 53 15.11 3206 2567 2.80 / 139.36 2 2
3 13 1002.08 16 15.20 1837 447 3.25 / 139.81 2 3
4 13 421.52 16 15.37 1011 249 3.49 / 140.06 2 3
5 8 0.24 165 15.45 349 890 4.38 / 140.95 2 8
Average= 4.27
(KJ/cycle)

Cycle 31 GMT 8/ 9/2020 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 29 15.40 518 231 0.23 / 132.47 2 3
2 7 2008.44 52 15.13 3214 2529 2.76 / 135.00 2 2
3 13 993.32 16 15.21 1833 446 3.21 / 135.44 2 3
4 13 415.00 16 15.38 1001 246 3.45 / 135.69 2 3
5 8 0.00 165 15.46 342 872 4.32 / 136.56 2 7
Average= 4.27
(KJ/cycle)

Cycle 30 GMT 29/ 8/2020 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 29 15.40 536 239 0.24 / 128.10 2 3
2 7 2006.48 53 15.15 3196 2566 2.81 / 130.67 2 2
3 13 1009.00 16 15.22 1853 451 3.26 / 131.12 2 3
4 13 419.00 16 15.37 1004 247 3.50 / 131.37 2 3
5 8 -0.20 165 15.46 342 872 4.38 / 132.24 2 7
Average= 4.27
(KJ/cycle)

Cycle 29 GMT 19/ 8/2020 8: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 29 15.40 517 231 0.23 / 123.77 2 3
2 7 2009.56 53 15.13 3218 2580 2.81 / 126.36 2 2
3 13 886.80 16 15.25 1677 409 3.22 / 126.76 2 3
4 13 341.88 16 15.40 884 218 3.44 / 126.98 2 3
5 8 0.36 165 15.46 345 880 4.32 / 127.86 2 7
Average= 4.26
(KJ/cycle)

Cycle 28 GMT 9/ 8/2020 10:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 29 15.41 517 231 0.23 / 119.46 2 3
2 7 2008.36 52 15.14 3202 2521 2.75 / 121.98 2 2
3 13 1008.88 16 15.21 1849 450 3.20 / 122.43 2 3
4 13 423.44 16 15.37 1007 248 3.45 / 122.67 2 3
5 8 -0.04 165 15.46 341 870 4.32 / 123.54 2 6
Average= 4.26
(KJ/cycle)

Cycle 27 GMT 30/ 7/2020 12:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 29 15.41 504 225 0.23 / 115.16 2 3
2 7 2010.68 52 15.14 3208 2526 2.75 / 117.69 2 2
3 13 903.04 16 15.25 1702 415 3.17 / 118.10 2 3
4 13 463.40 16 15.36 1065 262 3.43 / 118.36 2 3
5 8 -0.20 165 15.46 338 862 4.29 / 119.22 2 6
Average= 4.26
(KJ/cycle)

Cycle 26 GMT 20/ 7/2020 15: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 29 15.42 512 229 0.23 / 110.83 3 3
2 7 2003.00 53 15.15 3207 2575 2.80 / 113.41 2 2
3 13 995.80 16 15.22 1838 448 3.25 / 113.86 2 2
4 13 416.16 16 15.39 978 241 3.49 / 114.10 2 3
5 8 0.28 165 15.48 328 838 4.33 / 114.93 2 6
Average= 4.26
(KJ/cycle)

Cycle 25 GMT 10/ 7/2020 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 29 15.42 520 233 0.23 / 106.51 2 3
2 7 2006.76 53 15.14 3197 2565 2.80 / 109.07 2 2
3 13 998.92 16 15.23 1828 445 3.24 / 109.52 2 2
4 13 421.36 16 15.38 996 245 3.49 / 109.76 2 2
5 8 -0.04 165 15.47 330 842 4.33 / 110.60 2 7
Average= 4.25
(KJ/cycle)

Cycle 24 GMT 30/ 6/2020 19:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 29 15.42 508 227 0.23 / 102.17 2 3
2 7 2004.60 53 15.15 3192 2563 2.79 / 104.73 2 2
3 13 979.84 16 15.24 1803 440 3.23 / 105.17 2 2
4 13 407.80 16 15.38 981 241 3.47 / 105.41 2 2
5 8 0.12 165 15.47 337 860 4.33 / 106.27 2 6
Average= 4.25
(KJ/cycle)

Cycle 23 GMT 20/ 6/2020 22:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 29 15.42 482 216 0.22 / 97.74 2 3
2 7 2009.36 53 15.14 3205 2572 2.79 / 100.31 2 2
3 13 991.64 16 15.24 1822 444 3.23 / 100.76 2 2
4 13 413.40 16 15.40 987 243 3.47 / 101.00 2 2
5 13 51.52 16 15.50 429 106 3.58 / 101.11 2 2
6 8 -0.04 165 15.48 327 835 4.42 / 101.94 2 5
Average= 4.25
(KJ/cycle)

Cycle 22 GMT 11/ 6/2020 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 29 15.41 495 221 0.22 / 93.34 2 3
2 7 2005.52 53 15.16 3191 2564 2.79 / 95.91 2 2
3 13 990.56 16 15.24 1816 443 3.23 / 96.35 2 2
4 13 404.04 16 15.41 979 241 3.47 / 96.59 2 2
5 13 46.60 16 15.50 416 103 3.57 / 96.69 2 2
6 8 0.00 165 15.48 326 833 4.41 / 97.53 2 7
Average= 4.24
(KJ/cycle)

Cycle 21 GMT 1/ 6/2020 2:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 29 15.44 509 228 0.23 / 88.78 2 3
2 7 2006.16 53 15.16 3200 2571 2.80 / 91.35 2 2
3 13 996.88 16 15.24 1822 444 3.24 / 91.80 2 2
4 13 401.88 16 15.39 956 235 3.48 / 92.03 2 2
5 13 48.04 16 15.49 415 103 3.58 / 92.13 2 2
6 8 0.16 165 15.47 327 835 4.42 / 92.97 2 7
7 14 0.16 30 15.45 326 151 4.57 / 93.12 2 7
Average= 4.23
(KJ/cycle)

Cycle 20 GMT 22/ 5/2020 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 29 15.43 509 228 0.23 / 84.46 2 3
2 7 2004.04 52 15.17 3189 2516 2.74 / 86.98 2 2
3 13 982.28 16 15.26 1795 438 3.18 / 87.42 2 2
4 13 271.04 16 15.45 770 190 3.37 / 87.61 2 2
5 13 58.00 16 15.51 436 108 3.48 / 87.72 2 2
6 8 0.32 165 15.49 327 836 4.32 / 88.55 2 7
Average= 4.22
(KJ/cycle)

Cycle 19 GMT 12/ 5/2020 7:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 29 15.45 475 213 0.21 / 80.07 3 3
2 7 2004.28 53 15.16 3187 2561 2.77 / 82.63 2 2
3 13 985.60 16 15.25 1805 440 3.21 / 83.07 2 2
4 13 404.24 16 15.42 965 238 3.45 / 83.30 2 3
5 13 48.32 16 15.50 424 105 3.56 / 83.41 2 3
6 8 -0.04 165 15.48 324 828 4.38 / 84.24 2 4
Average= 4.21
(KJ/cycle)

Cycle 18 GMT 2/ 5/2020 10: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 29 15.44 487 218 0.22 / 75.58 3 3
2 7 2006.24 53 15.18 3209 2582 2.80 / 78.16 2 2
3 13 875.84 16 15.31 1650 404 3.20 / 78.56 2 2
4 13 318.32 16 15.44 838 207 3.41 / 78.77 2 3
5 13 41.12 16 15.53 409 102 3.51 / 78.87 2 3
6 8 -0.16 165 15.50 325 831 4.34 / 79.70 2 6
7 14 -0.16 30 15.48 322 150 4.49 / 79.85 3 8
Average= 4.20
(KJ/cycle)

Cycle 17 GMT 22/ 4/2020 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 15.45 501 224 0.22 / 71.01 2 3
2 7 2009.88 53 15.17 3204 2576 2.80 / 73.59 2 2
3 13 1002.52 16 15.26 1830 447 3.25 / 74.03 2 2
4 13 404.56 16 15.42 965 238 3.49 / 74.27 2 3
5 13 48.80 16 15.52 419 104 3.59 / 74.38 2 3
6 8 0.00 165 15.49 326 833 4.42 / 75.21 2 7
7 14 0.00 30 15.47 323 150 4.57 / 75.36 2 7
Average= 4.19
(KJ/cycle)

Cycle 16 GMT 12/ 4/2020 14:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 29 15.46 495 222 0.22 / 66.69 3 3
2 7 2002.48 53 15.18 3192 2568 2.79 / 69.26 2 2
3 13 871.44 16 15.31 1635 401 3.19 / 69.66 2 2
4 13 300.92 16 15.46 810 200 3.39 / 69.86 2 3
5 13 40.96 16 15.52 405 101 3.49 / 69.96 2 3
6 8 0.08 165 15.50 323 826 4.32 / 70.79 2 8
Average= 4.16
(KJ/cycle)

Cycle 15 GMT 2/ 4/2020 16:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 29 15.46 477 214 0.21 / 62.31 2 3
2 7 2002.56 53 15.18 3195 2571 2.78 / 64.88 2 2
3 13 986.00 16 15.28 1786 437 3.22 / 65.32 2 2
4 13 396.68 16 15.44 933 230 3.45 / 65.55 2 3
5 13 51.24 16 15.53 413 103 3.55 / 65.65 2 3
6 8 0.04 165 15.51 319 816 4.37 / 66.47 2 5
Average= 4.15
(KJ/cycle)

Cycle 14 GMT 23/ 3/2020 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 29 15.46 490 220 0.22 / 58.02 3 3
2 7 2004.84 52 15.19 3188 2518 2.74 / 60.53 2 2
3 13 980.16 16 15.28 1784 436 3.17 / 60.97 2 2
4 13 387.80 16 15.44 917 227 3.40 / 61.20 2 3
5 13 50.60 16 15.53 409 102 3.50 / 61.30 2 3
6 8 0.28 165 15.51 313 801 4.30 / 62.10 2 6
Average= 4.14
(KJ/cycle)

Cycle 13 GMT 13/ 3/2020 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 28 15.47 491 213 0.21 / 53.69 2 3
2 7 2003.76 53 15.19 3181 2561 2.77 / 56.25 2 2
3 13 978.16 16 15.28 1772 433 3.21 / 56.68 2 2
4 13 387.36 16 15.44 923 228 3.43 / 56.91 2 2
5 13 29.64 16 15.54 372 92 3.53 / 57.00 2 2
6 8 -0.04 165 15.51 310 793 4.32 / 57.80 2 4
Average= 4.13
(KJ/cycle)

Cycle 12 GMT 4/ 3/2020 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 28 15.45 481 208 0.21 / 49.24 2 3
2 7 2002.76 53 15.19 3191 2569 2.78 / 51.81 2 2
3 13 978.36 16 15.29 1780 435 3.21 / 52.24 2 2
4 13 278.28 16 15.47 762 189 3.40 / 52.43 2 2
5 13 36.48 16 15.54 389 97 3.50 / 52.53 2 2
6 8 0.08 165 15.51 313 801 4.30 / 53.33 2 5
7 14 0.08 30 15.49 310 144 4.44 / 53.47 2 11
Average= 4.11
(KJ/cycle)

Cycle 11 GMT 23/ 2/2020 2:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 28 15.46 490 212 0.21 / 44.86 3 3
2 7 2003.76 52 15.19 3191 2521 2.73 / 47.38 2 2
3 13 868.20 18 15.31 1619 446 3.18 / 47.82 2 2
4 13 170.88 18 15.49 602 168 3.35 / 47.99 2 2
5 13 19.48 18 15.53 360 101 3.45 / 48.09 2 3
6 8 0.08 165 15.50 311 795 4.24 / 48.89 2 4
7 14 0.08 30 15.48 309 143 4.39 / 49.03 2 9
Average= 4.09
(KJ/cycle)

Cycle 10 GMT 13/ 2/2020 4:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 30 15.46 487 226 0.23 / 40.54 3 3
2 3 951.76 -1 15.79 5 0 0.00 / 40.54 3 3
3 7 2002.80 52 15.19 3193 2522 2.75 / 43.06 2 2
4 13 978.16 18 15.28 1772 487 3.24 / 43.54 2 2
5 13 239.32 18 15.49 703 196 3.43 / 43.74 2 2
6 13 21.32 18 15.54 362 101 3.53 / 43.84 2 3
7 8 0.08 165 15.51 314 804 4.34 / 44.65 2 7
Average= 4.06
(KJ/cycle)

Cycle 9 GMT 3/ 2/2020 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 28 15.46 480 208 0.21 / 35.74 2 3
2 7 2002.24 74 14.97 3152 3492 3.70 / 39.23 2 2
3 13 197.92 18 15.50 638 178 3.88 / 39.41 2 2
4 13 37.08 18 15.55 384 107 3.98 / 39.52 2 3
5 8 0.08 165 15.51 310 793 4.78 / 40.31 2 7
Average= 4.03
(KJ/cycle)

Cycle 8 GMT 24/ 1/2020 9:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 28 15.46 491 213 0.21 / 30.97 2 3
2 7 2007.28 74 14.97 3148 3487 3.70 / 34.46 2 2
3 13 208.84 18 15.48 651 181 3.88 / 34.64 2 3
4 13 21.04 18 15.53 357 100 3.98 / 34.74 2 3
5 8 0.16 165 15.51 308 788 4.77 / 35.53 2 6
Average= 3.95
(KJ/cycle)

Cycle 7 GMT 14/ 1/2020 12:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 28 15.47 483 209 0.21 / 26.19 2 3
2 3 1016.44 1 15.51 1907 30 0.24 / 26.22 2 2
3 7 2002.96 74 14.96 3141 3477 3.72 / 29.70 2 2
4 13 185.12 18 15.49 619 173 3.89 / 29.87 2 2
5 13 16.88 18 15.54 351 98 3.99 / 29.97 2 3
6 8 0.12 165 15.51 309 791 4.78 / 30.76 2 6
Average= 3.85
(KJ/cycle)

Cycle 6 GMT 4/ 1/2020 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 27 15.47 485 203 0.20 / 21.33 2 3
2 10 1012.92 2 15.41 1864 57 0.26 / 21.39 2 3
3 7 2005.72 75 14.98 3149 3538 3.80 / 24.93 2 2
4 13 183.88 18 15.51 613 171 3.97 / 25.10 2 3
5 13 17.68 18 15.55 349 98 4.07 / 25.20 2 3
6 8 -0.04 165 15.52 308 789 4.86 / 25.98 2 11
Average= 3.71
(KJ/cycle)

Cycle 5 GMT 25/12/2019 17:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 25 15.49 482 187 0.19 / 16.59 2 3
2 10 1013.80 3 15.42 1870 87 0.27 / 16.68 2 3
3 7 2006.36 74 14.97 3150 3490 3.76 / 20.17 2 3
4 13 170.36 18 15.51 595 166 3.93 / 20.33 2 3
5 8 0.12 165 15.53 310 794 4.72 / 21.13 2 10
Average= 3.52
(KJ/cycle)

Cycle 4 GMT 15/12/2019 20:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 27 15.48 493 206 0.21 / 12.68 2 3
2 7 1526.00 74 15.17 2487 2792 3.00 / 15.47 2 2
3 13 116.36 18 15.55 512 143 3.14 / 15.61 2 3
4 8 0.04 165 15.54 310 795 3.94 / 16.41 2 6
Average= 3.28
(KJ/cycle)

Cycle 3 GMT 14/12/2019 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 27 15.48 494 206 0.21 / 8.74 2 3
2 3 1021.36 1 15.51 1904 30 0.24 / 8.77 2 2
3 7 1515.72 74 15.17 2460 2762 3.00 / 11.53 2 2
4 13 102.00 18 15.55 486 136 3.13 / 11.66 2 3
5 8 0.24 165 15.54 314 805 3.94 / 12.47 2 7
Average= 3.12
(KJ/cycle)

Cycle 2 GMT 13/12/2019 21:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 26 15.51 489 197 0.20 / 4.80 2 3
2 3 1025.68 1 15.53 1899 29 0.23 / 4.83 2 2
3 7 1505.68 74 15.17 2457 2758 2.98 / 7.59 2 2
4 13 111.92 18 15.54 505 141 3.13 / 7.73 2 3
5 8 0.04 165 15.54 313 803 3.93 / 8.53 2 5
Average= 2.84
(KJ/cycle)

Cycle 1 GMT 12/12/2019 21:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 23 15.69 439 158 0.16 / 1.70 3 3
2 10 1026.60 3 15.48 1860 86 0.24 / 1.78 2 3
3 3 1033.16 1 15.50 1911 30 0.27 / 1.81 2 2
4 7 1008.12 74 15.34 1759 1997 2.27 / 3.81 2 3
5 8 0.04 165 15.58 308 792 3.06 / 4.60 2 7
Average= 2.30
(KJ/cycle)

Cycle 0 GMT 12/12/2019 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.72 22 15.83 357 124 0.12 / 0.12 3 3
2 7 69.32 74 15.81 371 434 0.56 / 0.56 3 3
3 8 0.40 240 15.78 259 981 1.54 / 1.54 3 9
Average= 1.54