SIO Argo Site:
Pump Diagnostics Page   



Serial= 8805 WMO= 5906117

Return

←PreviousNext→

Cycle 189 GMT 13/12/2024 8:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 32 14.86 485 231 0.23 / 779.34 3 3
2 12 1327.40 2 15.02 2299 69 0.30 / 779.40 2 3
3 7 2003.32 53 14.79 3081 2415 2.71 / 781.82 2 3
4 13 1021.44 18 14.75 1768 469 3.18 / 782.29 2 4
5 13 411.48 18 14.84 914 244 3.43 / 782.53 2 4
6 8 0.16 170 14.91 295 748 4.18 / 783.28 3 3
Average= 4.12
(KJ/cycle)

Cycle 188 GMT 3/12/2024 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 32 14.84 481 228 0.23 / 775.22 3 3
2 12 1165.00 2 15.06 2044 62 0.29 / 775.28 2 3
3 7 2006.64 53 14.77 3072 2405 2.69 / 777.69 2 3
4 13 1010.24 18 14.73 1756 466 3.16 / 778.15 2 3
5 13 285.08 18 14.90 740 198 3.36 / 778.35 2 3
6 8 0.04 170 14.91 298 755 4.11 / 779.10 3 3
Average= 4.12
(KJ/cycle)

Cycle 187 GMT 23/11/2024 18:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 32 14.84 496 236 0.24 / 771.07 2 3
2 12 1323.36 2 15.03 2268 68 0.30 / 771.14 2 3
3 7 2013.68 52 14.78 3088 2373 2.68 / 773.51 2 3
4 13 1034.48 18 14.73 1788 474 3.15 / 773.98 2 3
5 13 427.16 18 14.84 939 251 3.40 / 774.24 2 3
6 8 0.16 170 14.91 298 755 4.16 / 774.99 2 3
Average= 4.12
(KJ/cycle)

Cycle 186 GMT 13/11/2024 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 32 14.85 494 235 0.23 / 766.94 2 3
2 12 1310.28 2 15.06 2263 68 0.30 / 767.00 2 3
3 7 2006.68 53 14.77 3085 2415 2.72 / 769.42 2 3
4 13 1008.44 18 14.74 1754 465 3.18 / 769.88 2 3
5 13 291.04 18 14.88 752 201 3.38 / 770.08 2 3
6 8 0.08 170 14.92 295 748 4.13 / 770.83 2 3
Average= 4.12
(KJ/cycle)

Cycle 185 GMT 4/11/2024 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 32 14.85 506 240 0.24 / 762.79 3 3
2 12 1312.84 2 15.03 2262 68 0.31 / 762.86 2 3
3 7 2003.12 53 14.78 3094 2424 2.73 / 765.28 2 3
4 13 1023.76 18 14.75 1782 473 3.21 / 765.76 2 3
5 13 189.40 18 14.91 606 163 3.37 / 765.92 2 3
6 8 0.08 170 14.92 308 781 4.15 / 766.70 2 3
Average= 4.12
(KJ/cycle)

Cycle 184 GMT 25/10/2024 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 32 14.85 476 226 0.23 / 758.54 3 3
2 12 1157.96 2 15.09 2046 62 0.29 / 758.60 2 3
3 7 2004.40 53 14.78 3089 2420 2.71 / 761.02 2 3
4 13 909.92 18 14.75 1617 429 3.14 / 761.45 2 4
5 13 341.12 18 14.86 818 219 3.36 / 761.67 2 3
6 8 0.04 170 14.92 304 771 4.13 / 762.44 3 3
7 14 0.04 25 14.89 303 113 4.24 / 762.55 2 4
Average= 4.12
(KJ/cycle)

Cycle 183 GMT 15/10/2024 14:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 32 14.85 481 229 0.23 / 754.35 3 3
2 12 1157.48 2 15.07 2021 61 0.29 / 754.41 2 3
3 7 2008.80 52 14.81 3081 2373 2.66 / 756.78 2 3
4 13 1019.08 18 14.74 1766 469 3.13 / 757.25 2 3
5 13 301.72 18 14.88 756 202 3.33 / 757.45 2 3
6 8 0.52 170 14.91 296 750 4.08 / 758.20 2 3
7 14 0.52 25 14.90 296 110 4.19 / 758.31 3 3
Average= 4.12
(KJ/cycle)

Cycle 182 GMT 5/10/2024 19: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 32 14.86 481 229 0.23 / 750.19 3 3
2 12 1154.68 2 15.08 2028 61 0.29 / 750.25 2 3
3 7 2007.00 53 14.79 3089 2421 2.71 / 752.67 2 3
4 13 1024.40 18 14.75 1777 472 3.18 / 753.14 2 3
5 13 305.04 18 14.90 771 207 3.39 / 753.35 2 3
6 8 -0.20 170 14.92 303 769 4.16 / 754.12 3 3
Average= 4.12
(KJ/cycle)

Cycle 181 GMT 25/ 9/2024 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 32 14.87 485 231 0.23 / 746.05 2 3
2 12 1317.92 2 15.04 2271 68 0.30 / 746.12 2 3
3 7 2006.04 53 14.79 3092 2424 2.72 / 748.55 2 3
4 13 1022.64 18 14.75 1774 471 3.19 / 749.02 2 3
5 13 292.40 18 14.90 753 202 3.40 / 749.22 2 3
6 8 0.20 170 14.93 292 741 4.14 / 749.96 2 3
Average= 4.12
(KJ/cycle)

Cycle 180 GMT 16/ 9/2024 4:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 32 14.87 499 237 0.24 / 741.96 2 3
2 12 1162.56 2 15.10 2040 62 0.30 / 742.02 2 2
3 7 2008.88 52 14.78 3090 2375 2.67 / 744.40 2 2
4 13 1013.36 18 14.76 1765 469 3.14 / 744.87 2 4
5 13 290.00 18 14.90 747 200 3.34 / 745.07 2 3
6 8 -0.04 170 14.94 297 754 4.10 / 745.82 2 3
Average= 4.12
(KJ/cycle)

Cycle 179 GMT 6/ 9/2024 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 32 14.86 498 237 0.24 / 737.77 3 3
2 12 1153.24 2 15.08 2033 61 0.30 / 737.83 2 3
3 7 2002.28 53 14.78 3065 2401 2.70 / 740.23 2 3
4 13 1015.64 18 14.74 1764 468 3.17 / 740.70 2 4
5 13 424.12 18 14.87 935 250 3.42 / 740.95 2 4
6 8 0.32 170 14.93 306 777 4.19 / 741.73 2 4
Average= 4.12
(KJ/cycle)

Cycle 178 GMT 27/ 8/2024 14:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 32 14.86 494 235 0.23 / 733.64 2 3
2 12 1322.00 2 15.05 2262 68 0.30 / 733.71 2 3
3 7 2004.32 53 14.79 3064 2402 2.70 / 736.11 2 3
4 13 1012.20 18 14.76 1760 468 3.17 / 736.58 2 3
5 13 294.28 18 14.91 751 202 3.37 / 736.78 2 3
6 8 0.00 170 14.92 297 753 4.13 / 737.53 3 3
Average= 4.12
(KJ/cycle)

Cycle 177 GMT 17/ 8/2024 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 32 14.86 498 237 0.24 / 729.48 2 3
2 12 1147.08 2 15.09 2026 61 0.30 / 729.54 2 3
3 7 2002.68 53 14.81 3079 2417 2.71 / 731.96 2 3
4 13 1020.20 18 14.76 1769 470 3.18 / 732.43 2 3
5 13 293.04 18 14.90 755 202 3.39 / 732.63 2 3
6 8 -0.04 170 14.92 305 774 4.16 / 733.40 2 3
Average= 4.12
(KJ/cycle)

Cycle 176 GMT 8/ 8/2024 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 32 14.87 496 236 0.24 / 725.30 2 3
2 12 1156.84 2 15.07 2032 61 0.30 / 725.36 2 3
3 7 2007.68 53 14.79 3099 2429 2.73 / 727.79 2 3
4 13 1002.28 18 14.77 1743 463 3.19 / 728.25 2 3
5 13 279.36 18 14.89 743 199 3.39 / 728.45 2 3
6 8 0.28 170 14.92 311 789 4.18 / 729.24 2 3
Average= 4.12
(KJ/cycle)

Cycle 175 GMT 29/ 7/2024 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 32 14.87 499 237 0.24 / 721.16 3 3
2 12 1331.92 2 15.05 2302 69 0.31 / 721.22 2 3
3 7 2005.24 53 14.79 3080 2414 2.72 / 723.64 2 3
4 13 1019.16 18 14.76 1769 470 3.19 / 724.11 2 3
5 13 307.20 18 14.92 771 207 3.40 / 724.32 2 3
6 8 0.12 170 14.94 295 749 4.15 / 725.07 3 3
Average= 4.12
(KJ/cycle)

Cycle 174 GMT 19/ 7/2024 10:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 32 14.86 497 236 0.24 / 716.94 2 3
2 12 1323.68 2 15.04 2279 69 0.30 / 717.01 2 3
3 7 2003.76 53 14.81 3085 2422 2.73 / 719.43 2 3
4 13 1023.32 18 14.78 1783 474 3.20 / 719.90 2 3
5 13 315.92 18 14.91 779 209 3.41 / 720.11 2 3
6 8 -0.20 170 14.93 317 805 4.21 / 720.92 2 4
Average= 4.12
(KJ/cycle)

Cycle 173 GMT 9/ 7/2024 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 32 14.86 502 239 0.24 / 712.61 2 3
2 12 1313.92 2 15.05 2271 68 0.31 / 712.68 2 3
3 7 2007.72 53 14.80 3095 2428 2.73 / 715.11 2 3
4 13 1017.08 18 14.77 1768 470 3.20 / 715.58 2 3
5 13 446.32 18 14.86 961 257 3.46 / 715.83 2 3
6 8 -0.20 170 14.94 299 759 4.22 / 716.59 3 3
7 14 -0.20 25 14.91 297 111 4.33 / 716.70 3 3
Average= 4.12
(KJ/cycle)

Cycle 172 GMT 29/ 6/2024 20:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 32 14.86 496 236 0.24 / 708.49 2 3
2 12 1160.48 2 15.10 2059 62 0.30 / 708.55 2 3
3 7 2004.44 52 14.81 3077 2370 2.67 / 710.92 3 3
4 13 1029.44 18 14.77 1776 472 3.14 / 711.39 2 4
5 13 312.32 18 14.91 785 211 3.35 / 711.60 2 3
6 8 0.36 170 14.93 302 767 4.12 / 712.37 3 3
Average= 4.12
(KJ/cycle)

Cycle 171 GMT 20/ 6/2024 1:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 32 14.86 511 243 0.24 / 704.30 2 3
2 12 1320.76 2 15.05 2293 69 0.31 / 704.37 2 3
3 7 2002.44 53 14.80 3101 2432 2.74 / 706.80 2 3
4 13 1020.04 18 14.77 1770 471 3.22 / 707.27 2 4
5 13 299.80 18 14.91 763 205 3.42 / 707.47 2 3
6 8 0.00 170 14.94 307 780 4.20 / 708.25 2 3
Average= 4.12
(KJ/cycle)

Cycle 170 GMT 10/ 6/2024 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 32 14.88 483 230 0.23 / 700.06 2 3
2 12 1163.20 2 15.10 2049 62 0.29 / 700.12 2 3
3 7 2006.12 53 14.79 3088 2421 2.71 / 702.55 2 3
4 13 1021.80 18 14.76 1773 471 3.18 / 703.02 2 4
5 13 409.12 18 14.88 928 249 3.43 / 703.26 2 3
6 8 0.16 170 14.94 311 790 4.22 / 704.05 3 3
Average= 4.12
(KJ/cycle)

Cycle 169 GMT 31/ 5/2024 11:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 32 14.86 489 233 0.23 / 695.91 3 3
2 12 1316.04 2 15.06 2269 68 0.30 / 695.98 2 3
3 7 2003.76 52 14.81 3087 2377 2.68 / 698.35 2 3
4 13 1143.20 18 14.74 1943 516 3.19 / 698.87 2 4
5 13 266.84 18 14.92 717 193 3.39 / 699.06 2 3
6 8 0.08 170 14.94 304 772 4.16 / 699.83 3 3
Average= 4.12
(KJ/cycle)

Cycle 168 GMT 21/ 5/2024 16:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 32 14.88 462 220 0.22 / 691.77 3 3
2 12 1163.08 2 15.07 2043 62 0.28 / 691.83 2 3
3 7 2008.04 53 14.79 3081 2415 2.70 / 694.25 2 3
4 13 1021.96 18 14.77 1772 471 3.17 / 694.72 2 3
5 13 290.08 18 14.91 745 200 3.37 / 694.92 2 3
6 8 0.24 170 14.94 298 757 4.12 / 695.67 3 3
Average= 4.12
(KJ/cycle)

Cycle 167 GMT 11/ 5/2024 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 32 14.88 490 233 0.23 / 687.55 3 3
2 12 1163.76 2 15.10 2052 62 0.30 / 687.61 2 3
3 7 2004.28 53 14.80 3073 2410 2.71 / 690.02 2 3
4 13 1022.52 18 14.76 1769 470 3.18 / 690.49 2 3
5 13 304.88 18 14.92 767 206 3.38 / 690.69 2 3
6 8 -0.20 170 14.94 294 747 4.13 / 691.44 3 3
7 14 -0.20 25 14.92 294 110 4.24 / 691.55 3 3
Average= 4.12
(KJ/cycle)

Cycle 166 GMT 2/ 5/2024 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 32 14.89 477 227 0.23 / 683.46 2 3
2 12 1166.88 2 15.08 2058 62 0.29 / 683.52 2 3
3 7 2003.00 52 14.81 3071 2365 2.65 / 685.89 2 3
4 13 1015.00 18 14.76 1762 468 3.12 / 686.36 2 3
5 13 287.04 18 14.92 741 199 3.32 / 686.55 2 3
6 8 0.16 170 14.94 298 757 4.08 / 687.31 3 5
Average= 4.12
(KJ/cycle)

Cycle 165 GMT 22/ 4/2024 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 14.86 492 234 0.23 / 679.34 2 3
2 12 1326.64 2 15.04 2270 68 0.30 / 679.41 2 3
3 7 2002.92 53 14.82 3100 2435 2.74 / 681.85 2 3
4 13 909.00 18 14.79 1619 431 3.17 / 682.28 2 3
5 13 320.00 18 14.91 783 210 3.38 / 682.49 2 4
6 8 0.20 170 14.95 293 745 4.12 / 683.23 3 3
Average= 4.12
(KJ/cycle)

Cycle 164 GMT 12/ 4/2024 12:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 32 14.88 499 238 0.24 / 675.13 2 3
2 12 1340.60 2 15.05 2300 69 0.31 / 675.20 2 3
3 7 2002.48 53 14.81 3098 2432 2.74 / 677.63 2 3
4 13 1029.72 18 14.77 1781 473 3.21 / 678.11 2 3
5 13 300.48 18 14.91 764 205 3.42 / 678.31 2 3
6 8 -0.12 170 14.93 315 800 4.22 / 679.11 3 3
Average= 4.12
(KJ/cycle)

Cycle 163 GMT 2/ 4/2024 17:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 32 14.88 489 233 0.23 / 670.91 2 3
2 12 1312.24 2 15.07 2261 68 0.30 / 670.98 2 3
3 7 2002.04 53 14.82 3073 2414 2.71 / 673.39 2 3
4 13 1022.32 18 14.78 1766 470 3.18 / 673.86 2 4
5 13 430.12 18 14.88 941 252 3.44 / 674.11 2 3
6 8 0.44 170 14.94 308 782 4.22 / 674.89 2 3
Average= 4.12
(KJ/cycle)

Cycle 162 GMT 23/ 3/2024 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 32 14.86 502 239 0.24 / 666.58 2 3
2 12 1326.08 2 15.05 2279 69 0.31 / 666.65 2 2
3 7 2004.52 53 14.81 3078 2416 2.72 / 669.07 2 2
4 13 1037.48 18 14.77 1799 478 3.20 / 669.55 2 4
5 13 754.40 18 14.79 1411 376 3.58 / 669.92 2 4
6 8 -0.04 170 14.95 296 752 4.33 / 670.68 2 3
Average= 4.11
(KJ/cycle)

Cycle 161 GMT 14/ 3/2024 3:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 32 14.86 500 238 0.24 / 662.30 2 3
2 12 1330.16 2 15.05 2294 69 0.31 / 662.37 2 3
3 7 2002.56 52 14.82 3085 2377 2.68 / 664.75 2 3
4 13 1014.00 18 14.78 1766 470 3.15 / 665.22 2 4
5 13 418.88 18 14.88 938 251 3.41 / 665.47 2 3
6 13 19.80 18 14.97 342 92 3.50 / 665.56 2 3
7 8 0.04 170 14.94 309 785 4.28 / 666.35 2 3
Average= 4.11
(KJ/cycle)

Cycle 160 GMT 4/ 3/2024 8:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 32 14.88 495 236 0.24 / 658.07 2 3
2 12 1328.32 2 15.05 2291 69 0.30 / 658.14 2 3
3 7 2005.28 54 14.79 3072 2453 2.76 / 660.59 2 2
4 13 1030.76 18 14.75 1783 473 3.23 / 661.07 2 4
5 13 309.28 18 14.91 777 209 3.44 / 661.28 2 3
6 8 0.40 170 14.94 310 787 4.23 / 662.06 2 3
Average= 4.11
(KJ/cycle)

Cycle 159 GMT 23/ 2/2024 13:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 32 14.87 485 231 0.23 / 653.96 2 3
2 12 1333.80 2 15.05 2288 69 0.30 / 654.03 2 2
3 7 2012.68 53 14.80 3084 2419 2.72 / 656.45 2 2
4 13 920.88 18 14.78 1634 435 3.15 / 656.88 2 3
5 13 225.76 18 14.92 654 176 3.33 / 657.06 2 3
6 8 -0.08 170 14.93 306 777 4.11 / 657.84 2 4
Average= 4.11
(KJ/cycle)

Cycle 158 GMT 13/ 2/2024 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 32 14.87 495 236 0.24 / 649.77 2 3
2 12 1323.68 2 15.06 2261 68 0.30 / 649.84 2 3
3 7 2003.68 53 14.81 3083 2420 2.72 / 652.26 2 3
4 13 1021.24 18 14.77 1768 470 3.19 / 652.73 2 4
5 13 298.92 18 14.91 758 203 3.40 / 652.94 2 3
6 8 0.16 170 14.94 313 795 4.19 / 653.73 2 3
Average= 4.11
(KJ/cycle)

Cycle 157 GMT 3/ 2/2024 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 32 14.87 499 237 0.24 / 645.48 2 3
2 12 1308.40 2 15.06 2254 68 0.31 / 645.55 2 3
3 7 2008.72 53 14.81 3088 2424 2.73 / 647.97 2 3
4 13 1040.36 18 14.77 1805 480 3.21 / 648.45 2 3
5 13 304.88 18 14.92 769 207 3.42 / 648.66 2 3
6 8 0.00 170 14.95 303 770 4.19 / 649.43 2 3
7 14 0.00 25 14.93 299 112 4.30 / 649.54 3 3
Average= 4.11
(KJ/cycle)

Cycle 156 GMT 25/ 1/2024 1:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 32 14.89 498 237 0.24 / 641.32 2 3
2 12 1155.00 2 15.08 2011 61 0.30 / 641.38 2 3
3 7 2006.64 53 14.80 3091 2425 2.72 / 643.80 2 2
4 13 1012.16 18 14.77 1757 467 3.19 / 644.27 2 3
5 13 285.04 18 14.92 744 200 3.39 / 644.47 2 3
6 8 0.36 170 14.95 304 773 4.16 / 645.24 3 3
Average= 4.11
(KJ/cycle)

Cycle 155 GMT 15/ 1/2024 3:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 32 14.87 472 225 0.22 / 637.07 2 3
2 12 1158.36 2 15.09 2016 61 0.29 / 637.13 2 3
3 7 2005.00 53 14.80 3077 2414 2.70 / 639.54 2 2
4 13 1024.20 18 14.78 1760 468 3.17 / 640.01 2 4
5 13 314.88 18 14.93 776 209 3.38 / 640.22 2 3
6 8 -0.04 170 14.96 295 750 4.13 / 640.97 2 4
7 14 -0.04 25 14.94 297 111 4.24 / 641.08 2 3
Average= 4.11
(KJ/cycle)

Cycle 154 GMT 5/ 1/2024 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 32 14.87 501 238 0.24 / 632.89 2 3
2 12 1144.08 2 15.11 2006 61 0.30 / 632.95 2 2
3 7 2004.40 53 14.82 3067 2409 2.71 / 635.36 2 3
4 13 1014.12 18 14.78 1758 468 3.18 / 635.83 2 3
5 13 407.64 18 14.87 921 247 3.42 / 636.08 2 4
6 8 0.40 170 14.95 301 765 4.19 / 636.84 2 3
Average= 4.11
(KJ/cycle)

Cycle 153 GMT 26/12/2023 8:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 32 14.88 507 241 0.24 / 628.73 2 3
2 12 1155.88 2 15.10 2038 62 0.30 / 628.79 2 3
3 7 2004.48 54 14.83 3078 2465 2.77 / 631.26 2 2
4 13 893.52 18 14.79 1595 425 3.19 / 631.68 2 4
5 13 316.72 18 14.93 782 210 3.40 / 631.89 2 3
6 8 -0.08 170 14.95 300 762 4.17 / 632.65 2 3
Average= 4.11
(KJ/cycle)

Cycle 152 GMT 16/12/2023 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 32 14.88 487 232 0.23 / 624.53 2 3
2 12 1171.36 2 15.10 2048 62 0.29 / 624.59 2 3
3 7 2002.04 53 14.81 3103 2436 2.73 / 627.02 2 2
4 13 1014.40 18 14.79 1763 469 3.20 / 627.49 2 3
5 13 274.48 18 14.93 730 196 3.39 / 627.69 2 3
6 8 0.08 170 14.95 315 801 4.20 / 628.49 3 3
Average= 4.11
(KJ/cycle)

Cycle 151 GMT 6/12/2023 13:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 32 14.88 493 235 0.23 / 620.22 2 3
2 12 1157.40 2 15.10 2028 61 0.30 / 620.28 2 3
3 7 2006.52 53 14.83 3087 2426 2.72 / 622.71 2 3
4 13 1026.92 18 14.79 1781 474 3.20 / 623.18 2 4
5 13 302.92 18 14.93 770 207 3.40 / 623.39 2 3
6 8 0.04 170 14.95 313 795 4.20 / 624.18 2 3
7 14 0.04 25 14.93 301 112 4.31 / 624.29 2 3
Average= 4.11
(KJ/cycle)

Cycle 150 GMT 26/11/2023 15:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 32 14.88 506 241 0.24 / 615.85 2 3
2 12 1312.28 2 15.07 2277 69 0.31 / 615.92 2 3
3 7 2006.08 53 14.81 3088 2424 2.73 / 618.35 2 2
4 13 1019.52 18 14.78 1765 470 3.20 / 618.81 2 3
5 13 555.16 18 14.85 1115 298 3.50 / 619.11 2 4
6 13 33.84 18 14.98 353 95 3.60 / 619.21 2 3
7 8 0.20 170 14.94 305 775 4.37 / 619.98 2 3
Average= 4.11
(KJ/cycle)

Cycle 149 GMT 16/11/2023 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 32 14.88 486 231 0.23 / 611.67 2 3
2 12 1160.72 2 15.11 2052 62 0.29 / 611.73 2 3
3 7 2002.40 53 14.83 3086 2426 2.72 / 614.16 2 2
4 13 1017.92 18 14.79 1770 471 3.19 / 614.63 2 3
5 13 285.00 18 14.94 744 200 3.39 / 614.83 2 3
6 8 0.08 170 14.96 307 781 4.17 / 615.61 2 3
Average= 4.10
(KJ/cycle)

Cycle 148 GMT 6/11/2023 20:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 32 14.90 496 236 0.24 / 607.33 2 3
2 12 1154.24 2 15.09 2051 62 0.30 / 607.39 2 3
3 7 2004.12 52 14.81 3082 2374 2.67 / 609.77 2 3
4 13 1001.44 18 14.79 1751 466 3.14 / 610.23 2 3
5 13 396.68 18 14.90 904 242 3.38 / 610.48 2 4
6 13 16.32 18 15.00 322 87 3.47 / 610.56 2 2
7 8 0.04 170 14.95 301 765 4.23 / 611.33 2 3
8 14 0.04 25 14.92 300 112 4.34 / 611.44 2 4
Average= 4.10
(KJ/cycle)

Cycle 147 GMT 27/10/2023 23: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 32 14.88 497 237 0.24 / 603.18 2 3
2 12 1312.76 2 15.07 2281 69 0.31 / 603.24 2 3
3 7 2005.80 53 14.82 3090 2427 2.73 / 605.67 2 2
4 13 1013.16 18 14.79 1763 469 3.20 / 606.14 2 4
5 13 282.00 18 14.94 734 197 3.40 / 606.34 2 3
6 8 0.12 170 14.97 298 758 4.16 / 607.10 2 3
Average= 4.10
(KJ/cycle)

Cycle 146 GMT 18/10/2023 1:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 32 14.88 497 237 0.24 / 598.98 2 3
2 12 1158.80 2 15.11 2052 62 0.30 / 599.04 2 3
3 7 2003.36 53 14.81 3087 2423 2.72 / 601.47 2 3
4 13 1014.24 18 14.78 1764 469 3.19 / 601.94 2 3
5 13 293.80 18 14.93 762 205 3.40 / 602.14 2 3
6 8 -0.04 170 14.95 314 798 4.19 / 602.94 2 3
Average= 4.10
(KJ/cycle)

Cycle 145 GMT 8/10/2023 3:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 32 14.90 498 237 0.24 / 594.82 2 3
2 12 1159.40 2 15.13 2037 62 0.30 / 594.89 2 3
3 7 2005.52 53 14.83 3074 2416 2.72 / 597.30 2 3
4 13 1012.28 18 14.77 1755 467 3.18 / 597.77 2 4
5 13 288.92 18 14.92 740 199 3.38 / 597.97 2 3
6 8 0.16 170 14.95 306 778 4.16 / 598.75 2 3
Average= 4.10
(KJ/cycle)

Cycle 144 GMT 28/ 9/2023 5:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 32 14.90 506 241 0.24 / 590.64 2 3
2 12 1307.44 2 15.09 2256 68 0.31 / 590.71 2 3
3 7 2007.52 52 14.81 3094 2383 2.69 / 593.09 2 3
4 13 1020.00 18 14.78 1771 471 3.16 / 593.56 2 3
5 13 441.20 18 14.89 957 256 3.42 / 593.82 2 3
6 8 -0.32 170 14.96 301 766 4.19 / 594.59 2 3
Average= 4.10
(KJ/cycle)

Cycle 143 GMT 18/ 9/2023 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 32 14.89 503 240 0.24 / 586.54 2 3
2 12 1319.56 2 15.05 2253 68 0.31 / 586.61 2 3
3 7 2004.56 52 14.82 3077 2371 2.68 / 588.98 2 2
4 13 1015.84 18 14.79 1764 470 3.15 / 589.45 2 3
5 13 279.48 18 14.94 723 194 3.34 / 589.64 2 3
6 8 0.40 170 14.96 299 760 4.10 / 590.40 2 5
Average= 4.10
(KJ/cycle)

Cycle 142 GMT 8/ 9/2023 10:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 32 14.88 492 234 0.23 / 582.34 2 3
2 12 1298.92 2 15.09 2230 67 0.30 / 582.40 2 3
3 7 2003.44 53 14.81 3089 2425 2.73 / 584.83 2 2
4 13 1006.12 18 14.80 1755 468 3.19 / 585.29 2 4
5 13 272.88 18 14.94 733 197 3.39 / 585.49 2 3
6 8 0.16 170 14.97 317 807 4.20 / 586.30 2 3
Average= 4.10
(KJ/cycle)

Cycle 141 GMT 29/ 8/2023 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 32 14.89 504 240 0.24 / 578.03 2 3
2 12 1321.32 2 15.08 2263 68 0.31 / 578.10 2 3
3 7 2003.20 53 14.82 3081 2420 2.73 / 580.52 2 3
4 13 1011.04 18 14.79 1761 469 3.20 / 580.99 2 3
5 13 305.48 18 14.93 773 208 3.40 / 581.19 2 3
6 8 -0.32 170 14.95 312 793 4.20 / 581.99 3 3
7 14 -0.32 25 14.92 308 115 4.31 / 582.10 3 3
Average= 4.10
(KJ/cycle)

Cycle 140 GMT 19/ 8/2023 15:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 32 14.89 495 236 0.24 / 573.85 3 3
2 12 1156.40 2 15.11 2033 61 0.30 / 573.91 2 3
3 7 2005.20 53 14.84 3095 2434 2.73 / 576.34 2 3
4 13 1024.28 18 14.78 1779 473 3.20 / 576.82 2 4
5 13 270.36 18 14.93 724 195 3.40 / 577.01 2 3
6 8 0.48 170 14.98 305 777 4.18 / 577.79 3 3
Average= 4.10
(KJ/cycle)

Cycle 139 GMT 9/ 8/2023 17:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 32 14.90 511 244 0.24 / 569.52 2 3
2 12 1158.40 2 15.10 2018 61 0.30 / 569.58 2 3
3 7 2006.24 53 14.82 3075 2415 2.72 / 572.00 2 3
4 13 901.68 18 14.82 1612 430 3.15 / 572.43 2 3
5 13 464.92 18 14.88 997 267 3.42 / 572.69 2 4
6 8 -0.04 170 14.95 316 803 4.22 / 573.50 2 3
7 14 -0.04 25 14.94 308 115 4.34 / 573.61 3 3
Average= 4.10
(KJ/cycle)

Cycle 138 GMT 30/ 7/2023 20: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 32 14.88 491 234 0.23 / 565.32 3 3
2 12 1154.00 2 15.12 2033 61 0.30 / 565.38 2 3
3 7 2005.00 53 14.84 3076 2419 2.71 / 567.80 2 3
4 13 1021.32 18 14.80 1770 472 3.19 / 568.27 2 3
5 13 293.96 18 14.94 759 204 3.39 / 568.48 2 4
6 8 0.16 170 14.95 315 801 4.19 / 569.28 2 3
Average= 4.10
(KJ/cycle)

Cycle 137 GMT 20/ 7/2023 22:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 32 14.87 487 232 0.23 / 561.23 2 3
2 12 1145.16 2 15.11 2008 61 0.29 / 561.29 2 3
3 7 2002.92 52 14.82 3073 2368 2.66 / 563.65 2 3
4 13 1017.92 18 14.80 1764 470 3.13 / 564.12 2 4
5 13 288.96 18 14.93 750 202 3.33 / 564.33 2 3
6 8 0.08 170 14.96 299 760 4.09 / 565.09 3 3
Average= 4.09
(KJ/cycle)

Cycle 136 GMT 11/ 7/2023 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 32 14.89 498 237 0.24 / 556.89 2 3
2 12 1156.20 2 15.11 2017 61 0.30 / 556.95 2 2
3 7 2003.96 53 14.83 3080 2421 2.72 / 559.37 2 2
4 13 1018.36 18 14.80 1766 470 3.19 / 559.84 2 3
5 13 428.00 18 14.91 940 252 3.44 / 560.09 2 4
6 8 0.04 170 14.96 309 786 4.23 / 560.88 2 3
7 14 0.04 25 14.94 304 114 4.34 / 560.99 3 3
Average= 4.09
(KJ/cycle)

Cycle 135 GMT 1/ 7/2023 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 32 14.89 492 234 0.23 / 552.72 2 3
2 12 1311.68 2 15.08 2262 68 0.30 / 552.79 2 3
3 7 2004.36 52 14.81 3096 2384 2.69 / 555.17 2 2
4 13 1006.40 18 14.79 1750 466 3.15 / 555.64 2 3
5 13 406.24 18 14.90 917 246 3.40 / 555.89 2 3
6 8 0.56 170 14.98 301 767 4.17 / 556.65 2 3
Average= 4.09
(KJ/cycle)

Cycle 134 GMT 21/ 6/2023 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 32 14.90 492 235 0.23 / 548.52 2 3
2 12 1325.72 2 15.05 2284 69 0.30 / 548.59 2 2
3 7 2004.64 53 14.82 3089 2426 2.73 / 551.01 2 3
4 13 1014.92 18 14.78 1761 468 3.20 / 551.48 2 3
5 13 429.56 18 14.89 946 254 3.45 / 551.73 2 3
6 8 -0.12 170 14.97 296 753 4.20 / 552.49 3 3
Average= 4.09
(KJ/cycle)

Cycle 133 GMT 11/ 6/2023 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 32 14.89 495 236 0.24 / 544.25 2 3
2 12 1322.80 2 15.06 2263 68 0.30 / 544.32 2 3
3 7 2006.48 53 14.83 3083 2423 2.73 / 546.74 2 3
4 13 1016.00 18 14.80 1765 470 3.20 / 547.21 2 4
5 13 287.52 18 14.93 743 200 3.40 / 547.41 2 3
6 8 -0.12 170 14.97 298 758 4.16 / 548.17 2 2
7 14 -0.12 25 14.94 297 111 4.27 / 548.28 3 2
Average= 4.09
(KJ/cycle)

Cycle 132 GMT 1/ 6/2023 10:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 14.91 500 239 0.24 / 539.86 2 3
2 12 1331.64 2 15.08 2294 69 0.31 / 539.93 2 3
3 7 2005.36 53 14.85 3089 2431 2.74 / 542.36 2 3
4 13 1017.76 18 14.81 1761 469 3.21 / 542.83 2 4
5 13 292.92 18 14.95 749 202 3.41 / 543.03 2 3
6 13 23.96 18 15.00 335 90 3.50 / 543.12 2 3
7 8 -0.24 170 14.98 305 777 4.28 / 543.90 3 3
8 14 -0.24 25 14.95 305 114 4.39 / 544.02 3 3
Average= 4.09
(KJ/cycle)

Cycle 131 GMT 22/ 5/2023 12:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 32 14.91 495 236 0.24 / 535.67 2 3
2 12 1317.16 2 15.10 2274 69 0.30 / 535.74 2 3
3 7 2004.36 53 14.83 3093 2431 2.74 / 538.17 2 3
4 13 1001.52 18 14.81 1750 467 3.20 / 538.64 2 4
5 13 274.08 18 14.96 728 196 3.40 / 538.84 2 3
6 8 0.36 170 14.97 310 789 4.19 / 539.62 3 3
Average= 4.09
(KJ/cycle)

Cycle 130 GMT 12/ 5/2023 15: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 32 14.91 504 240 0.24 / 531.37 2 3
2 12 1315.32 2 15.10 2267 68 0.31 / 531.44 2 3
3 7 2005.60 53 14.85 3082 2426 2.73 / 533.87 2 3
4 13 1013.76 18 14.82 1782 475 3.21 / 534.34 2 3
5 13 298.36 18 14.97 772 208 3.42 / 534.55 2 3
6 8 0.20 170 14.98 305 777 4.19 / 535.33 3 3
7 14 0.20 25 14.95 298 111 4.31 / 535.44 3 3
Average= 4.09
(KJ/cycle)

Cycle 129 GMT 2/ 5/2023 17:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 32 14.91 499 238 0.24 / 527.17 2 3
2 12 1299.32 2 15.11 2242 68 0.31 / 527.24 2 3
3 7 2004.76 53 14.83 3094 2432 2.74 / 529.67 2 3
4 13 1004.40 18 14.81 1750 467 3.20 / 530.14 2 3
5 13 297.96 18 14.94 765 206 3.41 / 530.34 2 3
6 8 -0.24 170 14.98 310 789 4.20 / 531.13 2 3
Average= 4.09
(KJ/cycle)

Cycle 128 GMT 22/ 4/2023 19:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 32 14.89 470 224 0.22 / 522.94 2 3
2 12 1157.32 2 15.13 2021 61 0.29 / 523.00 2 3
3 7 2003.68 53 14.84 3084 2426 2.71 / 525.43 2 2
4 13 1004.00 18 14.82 1754 468 3.18 / 525.90 2 3
5 13 407.28 18 14.93 916 246 3.42 / 526.14 2 3
6 8 -0.04 170 14.98 310 789 4.21 / 526.93 2 3
Average= 4.08
(KJ/cycle)

Cycle 127 GMT 12/ 4/2023 22: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 32 14.91 499 238 0.24 / 518.68 3 3
2 12 1314.72 2 15.07 2257 68 0.31 / 518.74 2 3
3 7 2001.96 53 14.84 3101 2439 2.75 / 521.18 2 3
4 13 1006.44 18 14.81 1737 463 3.21 / 521.65 2 4
5 13 278.28 18 14.95 728 196 3.40 / 521.84 2 3
6 8 0.08 170 14.98 300 764 4.17 / 522.61 2 3
7 14 0.08 25 14.95 297 111 4.28 / 522.72 2 3
Average= 4.08
(KJ/cycle)

Cycle 126 GMT 3/ 4/2023 0:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 32 14.92 470 224 0.22 / 514.42 3 3
2 12 1328.40 2 15.10 2271 69 0.29 / 514.49 2 3
3 7 2001.60 53 14.85 3082 2426 2.72 / 516.91 2 3
4 13 1007.68 18 14.80 1749 466 3.18 / 517.38 2 3
5 13 291.60 18 14.94 747 201 3.39 / 517.58 2 3
6 8 -0.16 170 14.99 294 749 4.13 / 518.33 3 3
7 14 -0.16 25 14.97 293 110 4.24 / 518.44 3 3
Average= 4.08
(KJ/cycle)

Cycle 125 GMT 24/ 3/2023 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 32 14.91 486 232 0.23 / 510.28 3 3
2 12 1321.36 2 15.08 2261 68 0.30 / 510.35 2 3
3 7 2003.72 53 14.85 3070 2416 2.72 / 512.76 2 3
4 13 1023.52 18 14.81 1774 473 3.19 / 513.24 2 3
5 13 300.96 18 14.95 756 203 3.39 / 513.44 2 3
6 8 0.12 170 14.98 296 754 4.15 / 514.19 3 3
Average= 4.08
(KJ/cycle)

Cycle 124 GMT 14/ 3/2023 5: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 32 14.92 473 226 0.23 / 506.02 2 3
2 12 1320.72 2 15.10 2281 69 0.29 / 506.09 2 3
3 7 2004.44 53 14.83 3101 2437 2.73 / 508.53 2 3
4 13 997.76 18 14.83 1734 463 3.19 / 508.99 2 4
5 13 272.76 18 14.96 716 193 3.39 / 509.19 2 4
6 8 -0.04 170 14.98 295 751 4.14 / 509.94 2 3
7 14 -0.04 25 14.96 296 111 4.25 / 510.05 3 3
Average= 4.08
(KJ/cycle)

Cycle 123 GMT 4/ 3/2023 7:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 32 14.91 473 226 0.23 / 501.80 2 3
2 12 1314.68 2 15.10 2255 68 0.29 / 501.87 2 3
3 7 2003.48 52 14.85 3080 2378 2.67 / 504.25 2 2
4 13 1015.04 18 14.81 1755 468 3.14 / 504.71 2 5
5 13 296.12 18 14.96 754 203 3.34 / 504.92 2 3
6 8 0.64 170 14.99 301 767 4.11 / 505.68 2 3
7 14 0.64 25 14.96 302 113 4.22 / 505.80 2 3
Average= 4.08
(KJ/cycle)

Cycle 122 GMT 22/ 2/2023 9:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 32 14.90 501 239 0.24 / 497.64 2 3
2 12 1135.92 2 15.13 2009 61 0.30 / 497.70 2 3
3 7 2005.80 53 14.83 3098 2435 2.73 / 500.13 2 3
4 13 1011.48 18 14.81 1764 470 3.20 / 500.60 2 4
5 13 292.88 18 14.95 748 201 3.41 / 500.81 2 3
6 8 0.00 170 14.99 302 770 4.18 / 501.57 2 3
Average= 4.08
(KJ/cycle)

Cycle 121 GMT 12/ 2/2023 11:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 32 14.91 491 234 0.23 / 493.29 2 3
2 12 1302.32 2 15.09 2256 68 0.30 / 493.36 2 3
3 7 2006.00 53 14.83 3094 2432 2.73 / 495.79 2 3
4 13 1005.12 18 14.80 1746 465 3.20 / 496.25 2 3
5 13 411.12 18 14.92 921 247 3.45 / 496.50 2 3
6 8 0.20 170 14.97 308 784 4.23 / 497.29 2 3
7 14 0.20 25 14.95 303 113 4.34 / 497.40 2 3
Average= 4.08
(KJ/cycle)

Cycle 120 GMT 2/ 2/2023 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 32 14.92 485 232 0.23 / 488.90 2 3
2 12 1307.36 2 15.11 2239 68 0.30 / 488.97 2 3
3 7 2006.60 53 14.84 3095 2434 2.73 / 491.40 2 2
4 13 1148.52 18 14.79 1949 519 3.25 / 491.92 2 4
5 13 389.08 18 14.94 890 239 3.49 / 492.16 2 4
6 8 -0.04 170 14.99 305 777 4.27 / 492.94 2 3
7 14 -0.04 25 14.97 309 116 4.38 / 493.06 3 3
Average= 4.07
(KJ/cycle)

Cycle 119 GMT 23/ 1/2023 16:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 32 14.92 520 248 0.25 / 484.73 2 3
2 3 1017.72 1 15.01 1839 28 0.28 / 484.76 2 3
3 12 1163.28 2 15.11 2061 62 0.34 / 484.82 2 2
4 7 2004.16 53 14.83 3076 2418 2.76 / 487.24 2 2
5 13 1008.40 18 14.82 1755 468 3.22 / 487.71 2 3
6 13 296.88 18 14.96 760 205 3.43 / 487.91 2 3
7 8 0.12 170 15.00 298 760 4.19 / 488.67 2 3
Average= 4.07
(KJ/cycle)

Cycle 118 GMT 13/ 1/2023 18:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 31 14.91 497 230 0.23 / 480.41 2 3
2 3 1034.04 1 14.98 1875 28 0.26 / 480.44 2 3
3 12 1335.04 2 15.10 2303 70 0.33 / 480.51 2 3
4 7 2001.68 52 14.84 3081 2378 2.70 / 482.89 2 3
5 13 1017.24 18 14.82 1773 473 3.18 / 483.36 2 3
6 13 277.68 18 14.99 730 197 3.37 / 483.56 2 3
7 8 0.32 170 15.00 316 806 4.18 / 484.37 2 3
8 14 0.32 25 14.97 313 117 4.30 / 484.48 3 3
Average= 4.07
(KJ/cycle)

Cycle 117 GMT 3/ 1/2023 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 30 14.92 508 227 0.23 / 476.05 2 3
2 10 1043.20 2 14.88 1872 56 0.28 / 476.10 2 3
3 12 1180.00 2 15.11 2100 63 0.35 / 476.16 2 3
4 7 2003.80 53 14.84 3094 2433 2.78 / 478.60 2 3
5 13 989.68 18 14.82 1733 462 3.24 / 479.06 2 4
6 13 269.16 18 14.96 736 198 3.44 / 479.26 2 4
7 8 -0.12 170 14.99 317 808 4.25 / 480.07 2 2
8 14 -0.12 25 14.95 315 118 4.37 / 480.18 2 3
Average= 4.07
(KJ/cycle)

Cycle 116 GMT 24/12/2022 23: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 29 14.91 487 211 0.21 / 471.76 2 3
2 10 1010.04 2 14.89 1817 54 0.26 / 471.81 2 3
3 3 969.60 -1 15.31 4 0 0.05 / 471.81 2 3
4 12 1341.32 2 15.08 2302 69 0.33 / 471.88 2 3
5 7 2004.40 53 14.85 3095 2436 2.77 / 474.31 2 3
6 13 997.12 18 14.83 1751 467 3.24 / 474.78 2 4
7 13 383.36 18 14.94 897 241 3.48 / 475.02 2 4
8 8 0.04 170 14.99 312 795 4.27 / 475.82 2 3
Average= 4.07
(KJ/cycle)

Cycle 115 GMT 15/12/2022 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 29 14.94 498 216 0.22 / 467.39 2 3
2 12 1335.08 2 15.08 2301 69 0.29 / 467.46 2 2
3 7 2006.28 53 14.85 3089 2431 2.72 / 469.90 2 2
4 13 998.44 18 14.84 1741 465 3.18 / 470.36 2 4
5 13 279.00 18 14.97 740 199 3.38 / 470.56 2 3
6 13 22.92 18 15.02 328 89 3.47 / 470.65 2 2
7 8 0.36 170 14.98 307 782 4.25 / 471.43 2 3
8 14 0.36 25 14.96 305 114 4.37 / 471.54 2 3
Average= 4.07
(KJ/cycle)

Cycle 114 GMT 5/12/2022 3:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 29 14.92 512 222 0.22 / 463.22 2 3
2 12 1330.40 2 15.08 2285 69 0.29 / 463.29 2 3
3 7 2002.96 53 14.84 3079 2422 2.71 / 465.71 2 3
4 13 987.28 18 14.84 1727 461 3.17 / 466.17 2 4
5 13 379.64 18 14.94 883 237 3.41 / 466.41 2 4
6 8 -0.28 170 15.00 302 770 4.18 / 467.18 2 3
Average= 4.06
(KJ/cycle)

Cycle 113 GMT 25/11/2022 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 30 14.94 514 230 0.23 / 459.12 2 3
2 12 1300.88 2 15.11 2248 68 0.30 / 459.18 2 3
3 7 2001.24 53 14.84 3072 2416 2.71 / 461.60 2 3
4 13 840.60 18 14.86 1529 409 3.12 / 462.01 2 5
5 13 274.64 18 14.98 743 200 3.32 / 462.21 2 4
6 8 -0.08 170 15.02 309 789 4.11 / 463.00 2 3
Average= 4.06
(KJ/cycle)

Cycle 112 GMT 15/11/2022 7:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 30 14.93 501 224 0.22 / 454.97 2 3
2 12 1289.08 2 15.10 2240 68 0.29 / 455.04 2 3
3 7 2003.20 52 14.86 3082 2382 2.67 / 457.42 2 3
4 13 977.72 18 14.85 1732 463 3.14 / 457.88 2 3
5 13 252.40 18 15.00 713 193 3.33 / 458.07 2 3
6 8 0.24 170 15.00 318 811 4.14 / 458.89 2 3
Average= 4.06
(KJ/cycle)

Cycle 111 GMT 5/11/2022 9:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 29 14.92 491 212 0.21 / 450.79 2 3
2 3 1031.64 1 14.99 1876 28 0.24 / 450.81 2 3
3 12 1264.76 2 15.10 2204 67 0.31 / 450.88 2 3
4 7 2003.56 53 14.84 3111 2447 2.75 / 453.33 2 3
5 13 848.80 18 14.86 1536 411 3.16 / 453.74 2 4
6 13 302.80 18 14.98 786 212 3.38 / 453.95 2 3
7 8 0.08 170 15.00 312 796 4.17 / 454.75 2 3
Average= 4.06
(KJ/cycle)

Cycle 110 GMT 26/10/2022 11:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 29 14.92 497 215 0.22 / 446.58 2 3
2 12 1199.44 2 15.13 2096 63 0.28 / 446.64 2 3
3 7 2002.32 53 14.86 3082 2427 2.71 / 449.07 2 3
4 13 879.12 18 14.87 1584 424 3.13 / 449.49 2 5
5 13 287.76 18 14.98 745 201 3.33 / 449.69 2 3
6 8 0.08 170 15.01 300 766 4.10 / 450.46 2 3
7 14 0.08 25 15.00 302 113 4.21 / 450.57 2 3
Average= 4.06
(KJ/cycle)

Cycle 109 GMT 16/10/2022 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 30 14.92 492 220 0.22 / 442.53 2 3
2 12 1286.68 2 15.11 2224 67 0.29 / 442.60 2 3
3 7 2003.00 52 14.85 3090 2386 2.67 / 444.98 2 2
4 13 829.88 18 14.87 1513 405 3.08 / 445.39 2 4
5 13 259.32 18 14.98 713 192 3.27 / 445.58 2 3
6 8 0.16 170 15.00 307 783 4.05 / 446.36 2 3
Average= 4.06
(KJ/cycle)

Cycle 108 GMT 6/10/2022 14:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 30 14.93 511 229 0.23 / 438.43 2 3
2 12 1261.52 2 15.12 2202 67 0.30 / 438.50 2 3
3 7 2002.68 53 14.85 3079 2423 2.72 / 440.92 2 3
4 13 832.40 18 14.88 1523 408 3.13 / 441.33 2 4
5 13 272.56 18 14.97 729 196 3.32 / 441.53 2 4
6 8 0.04 170 15.00 307 783 4.11 / 442.31 2 3
Average= 4.06
(KJ/cycle)

Cycle 107 GMT 26/ 9/2022 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 30 14.93 479 215 0.21 / 434.22 2 3
2 3 1018.00 1 15.00 1841 28 0.24 / 434.24 2 3
3 12 1310.60 2 15.10 2262 68 0.31 / 434.31 2 3
4 7 2005.76 52 14.85 3107 2399 2.71 / 436.71 2 3
5 13 856.68 18 14.86 1548 414 3.12 / 437.12 2 3
6 13 293.48 18 14.97 758 204 3.33 / 437.33 2 4
7 8 -0.04 170 15.00 299 762 4.09 / 438.09 2 3
8 14 -0.04 25 14.98 301 113 4.20 / 438.20 2 3
Average= 4.06
(KJ/cycle)

Cycle 106 GMT 16/ 9/2022 18:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 30 14.93 505 226 0.23 / 430.11 2 3
2 12 1324.32 2 15.09 2279 69 0.29 / 430.18 2 3
3 7 2003.80 53 14.86 3085 2430 2.72 / 432.61 2 3
4 13 849.76 18 14.87 1545 414 3.14 / 433.02 2 3
5 13 282.12 18 14.98 747 201 3.34 / 433.22 2 3
6 8 0.16 170 15.01 306 781 4.12 / 434.00 2 3
Average= 4.06
(KJ/cycle)

Cycle 105 GMT 6/ 9/2022 20:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 30 14.94 499 224 0.22 / 425.89 2 3
2 12 1312.24 2 15.12 2281 69 0.29 / 425.96 2 3
3 7 2001.88 53 14.84 3100 2438 2.73 / 428.40 2 3
4 13 972.56 18 14.85 1714 458 3.19 / 428.86 2 4
5 13 358.68 18 14.96 859 231 3.42 / 429.09 2 4
6 8 -0.24 170 15.01 311 794 4.21 / 429.88 2 3
Average= 4.06
(KJ/cycle)

Cycle 104 GMT 27/ 8/2022 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 14.94 483 209 0.21 / 421.62 2 3
2 3 1022.20 1 14.99 1844 28 0.24 / 421.65 2 3
3 12 1296.92 2 15.12 2253 68 0.31 / 421.72 2 2
4 7 2001.08 53 14.87 3091 2436 2.74 / 424.15 2 2
5 13 852.16 18 14.88 1547 414 3.16 / 424.57 2 4
6 13 281.92 18 14.99 755 204 3.36 / 424.77 2 4
7 8 -0.04 170 15.02 306 781 4.14 / 425.55 2 2
8 14 -0.04 25 14.99 309 116 4.26 / 425.67 2 2
Average= 4.05
(KJ/cycle)

Cycle 103 GMT 17/ 8/2022 23:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 29 14.94 485 210 0.21 / 417.21 2 3
2 12 1326.60 2 15.09 2304 70 0.28 / 417.28 2 3
3 7 2003.92 53 14.84 3094 2433 2.71 / 419.71 2 3
4 13 1001.52 18 14.85 1751 468 3.18 / 420.18 2 3
5 13 385.96 18 14.97 898 242 3.42 / 420.42 2 4
6 13 39.80 18 15.05 362 98 3.52 / 420.52 2 3
7 8 0.08 170 15.01 305 778 4.30 / 421.30 2 3
8 14 0.08 25 14.99 303 114 4.41 / 421.41 3 3
Average= 4.05
(KJ/cycle)

Cycle 102 GMT 8/ 8/2022 1:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 29 14.92 507 219 0.22 / 412.97 2 3
2 12 1285.00 2 15.11 2243 68 0.29 / 413.04 2 3
3 7 2003.92 53 14.86 3085 2430 2.72 / 415.47 2 2
4 13 867.20 18 14.88 1566 419 3.14 / 415.89 2 4
5 13 308.96 18 14.98 789 213 3.35 / 416.10 2 4
6 8 0.20 170 15.01 306 781 4.13 / 416.88 2 3
7 14 0.20 25 14.98 305 114 4.24 / 417.00 2 3
Average= 4.05
(KJ/cycle)

Cycle 101 GMT 29/ 7/2022 2:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 29 14.95 498 216 0.22 / 408.72 2 3
2 3 1023.36 1 15.01 1831 27 0.24 / 408.74 2 3
3 12 1293.32 2 15.11 2234 68 0.31 / 408.81 2 3
4 7 2002.24 53 14.85 3092 2434 2.74 / 411.25 2 2
5 13 829.24 18 14.88 1511 405 3.15 / 411.65 2 4
6 13 258.56 18 14.99 718 194 3.34 / 411.84 2 4
7 8 -0.08 170 15.01 310 791 4.13 / 412.64 2 3
8 14 -0.08 25 15.00 314 118 4.25 / 412.75 2 3
Average= 4.05
(KJ/cycle)

Cycle 100 GMT 19/ 7/2022 4:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.92 482 209 0.21 / 404.59 2 3
2 10 1033.68 3 14.89 1866 83 0.29 / 404.67 2 3
3 3 922.84 -1 15.31 3 0 0.08 / 404.67 2 3
4 3 925.64 -1 15.34 3 0 0.08 / 404.67 2 3
5 12 1289.52 2 15.11 2235 68 0.36 / 404.74 2 3
6 7 2002.44 52 14.87 3100 2397 2.76 / 407.14 2 2
7 13 841.20 18 14.89 1524 408 3.16 / 407.55 2 3
8 13 262.72 18 15.00 714 193 3.36 / 407.74 2 3
9 8 0.24 170 15.02 298 761 4.12 / 408.50 2 3
Average= 4.04
(KJ/cycle)

Cycle 99 GMT 9/ 7/2022 6:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 29 14.94 501 217 0.22 / 400.33 2 3
2 12 1259.76 2 15.10 2193 66 0.28 / 400.40 2 2
3 7 2002.20 52 14.86 3085 2384 2.67 / 402.78 2 2
4 13 975.88 18 14.84 1714 458 3.12 / 403.24 2 3
5 13 510.28 18 14.93 1066 286 3.41 / 403.53 2 5
6 13 16.28 18 15.03 320 87 3.50 / 403.61 2 2
7 8 -0.12 170 15.00 302 770 4.27 / 404.38 2 2
Average= 4.04
(KJ/cycle)

Cycle 98 GMT 29/ 6/2022 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 14.95 478 207 0.21 / 396.18 2 3
2 12 1313.24 2 15.09 2265 68 0.28 / 396.24 2 2
3 7 2003.56 52 14.86 3096 2392 2.67 / 398.64 2 3
4 13 863.20 18 14.86 1554 416 3.08 / 399.05 2 4
5 13 298.52 18 14.97 758 204 3.29 / 399.26 2 3
6 8 -0.04 170 15.02 293 748 4.04 / 400.00 2 3
7 14 -0.04 25 14.99 295 111 4.15 / 400.11 2 3
Average= 4.04
(KJ/cycle)

Cycle 97 GMT 19/ 6/2022 10:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 29 14.94 493 214 0.21 / 392.13 2 3
2 12 1158.80 2 15.15 2024 61 0.27 / 392.19 2 2
3 7 2003.52 53 14.86 3083 2428 2.70 / 394.62 2 3
4 13 842.40 18 14.87 1529 409 3.11 / 395.03 2 4
5 13 269.28 18 14.99 718 194 3.31 / 395.22 2 4
6 8 -0.08 170 15.01 293 748 4.05 / 395.97 2 3
Average= 4.04
(KJ/cycle)

Cycle 96 GMT 9/ 6/2022 12:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 30 14.95 503 226 0.23 / 388.04 2 3
2 12 1287.28 2 15.12 2224 67 0.29 / 388.11 2 2
3 7 2002.48 53 14.87 3092 2437 2.73 / 390.54 2 2
4 13 852.84 18 14.86 1548 414 3.14 / 390.96 2 3
5 13 288.32 18 14.97 747 201 3.35 / 391.16 2 3
6 8 0.32 170 15.01 296 755 4.10 / 391.91 2 2
Average= 4.04
(KJ/cycle)

Cycle 95 GMT 30/ 5/2022 14:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 30 14.95 479 215 0.21 / 383.97 2 3
2 12 1274.96 2 15.12 2219 67 0.28 / 384.03 2 2
3 7 2005.40 53 14.84 3087 2428 2.71 / 386.46 2 2
4 13 846.12 18 14.88 1529 410 3.12 / 386.87 2 4
5 13 270.56 18 14.98 724 195 3.31 / 387.07 2 4
6 8 -0.04 170 15.01 293 748 4.06 / 387.81 2 3
Average= 4.04
(KJ/cycle)

Cycle 94 GMT 20/ 5/2022 16:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 14.94 496 222 0.22 / 379.87 2 3
2 12 1290.12 2 15.10 2233 67 0.29 / 379.94 2 2
3 7 2001.32 52 14.87 3100 2397 2.69 / 382.34 2 2
4 13 984.80 18 14.84 1734 463 3.15 / 382.80 2 5
5 13 278.20 18 14.98 740 200 3.35 / 383.00 2 4
6 8 0.44 170 15.02 294 751 4.10 / 383.75 2 3
Average= 4.04
(KJ/cycle)

Cycle 93 GMT 10/ 5/2022 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 30 14.95 482 216 0.22 / 375.60 2 3
2 12 1314.28 2 15.12 2263 68 0.28 / 375.67 2 3
3 7 2002.48 53 14.86 3092 2435 2.72 / 378.10 2 3
4 13 978.00 18 14.85 1719 459 3.18 / 378.56 2 4
5 13 373.32 18 14.97 866 233 3.41 / 378.80 2 4
6 8 0.04 170 15.02 292 746 4.16 / 379.54 2 2
7 14 0.04 25 15.00 291 109 4.27 / 379.65 2 3
Average= 4.04
(KJ/cycle)

Cycle 92 GMT 30/ 4/2022 20:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 30 14.94 479 215 0.21 / 371.26 2 3
2 12 1313.04 2 15.11 2266 68 0.28 / 371.32 2 2
3 7 2001.36 53 14.86 3082 2427 2.71 / 373.75 2 3
4 13 942.60 18 14.86 1662 445 3.16 / 374.20 2 4
5 13 353.92 18 14.99 836 226 3.38 / 374.42 2 4
6 13 43.40 18 15.06 354 96 3.48 / 374.52 2 3
7 8 -0.04 170 15.02 296 756 4.23 / 375.27 3 3
8 14 -0.04 25 15.00 294 110 4.34 / 375.38 2 3
Average= 4.04
(KJ/cycle)

Cycle 91 GMT 20/ 4/2022 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 29 14.95 487 211 0.21 / 366.92 2 3
2 3 1017.68 1 15.03 1848 28 0.24 / 366.95 2 3
3 12 1286.60 2 15.12 2223 67 0.31 / 367.02 2 3
4 7 2005.24 53 14.87 3093 2438 2.74 / 369.46 2 3
5 13 859.60 18 14.88 1536 411 3.16 / 369.87 2 5
6 13 278.80 18 14.99 734 198 3.35 / 370.07 2 4
7 13 26.92 18 15.05 331 90 3.44 / 370.15 2 2
8 8 0.72 170 15.01 303 773 4.22 / 370.93 2 3
9 14 0.72 25 14.99 303 114 4.33 / 371.04 2 3
Average= 4.03
(KJ/cycle)

Cycle 90 GMT 11/ 4/2022 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 29 14.93 487 211 0.21 / 362.85 2 3
2 12 1169.04 2 15.16 2065 63 0.27 / 362.92 2 3
3 7 2002.92 53 14.87 3086 2432 2.71 / 365.35 2 3
4 13 840.56 18 14.89 1530 410 3.12 / 365.76 2 3
5 13 281.92 18 14.99 735 198 3.31 / 365.96 2 4
6 8 -0.48 170 15.03 296 756 4.07 / 366.71 2 3
Average= 4.03
(KJ/cycle)

Cycle 89 GMT 1/ 4/2022 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 29 14.96 477 207 0.21 / 358.37 2 3
2 12 1323.64 2 15.11 2285 69 0.28 / 358.44 2 2
3 7 2001.00 52 14.86 3077 2378 2.65 / 360.82 2 3
4 13 964.08 18 14.86 1682 450 3.10 / 361.27 2 4
5 13 488.16 18 14.93 1018 274 3.38 / 361.54 2 4
6 13 400.44 18 14.94 889 239 3.62 / 361.78 2 4
7 8 0.32 170 15.00 293 747 4.36 / 362.53 2 3
8 14 0.32 25 14.98 296 111 4.47 / 362.64 3 3
Average= 4.03
(KJ/cycle)

Cycle 88 GMT 22/ 3/2022 3:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 30 14.94 498 223 0.22 / 354.32 2 3
2 12 1275.20 2 15.11 2213 67 0.29 / 354.38 2 2
3 7 2006.28 53 14.85 3092 2434 2.72 / 356.82 2 2
4 13 754.80 18 14.89 1407 377 3.10 / 357.19 2 3
5 13 330.20 18 14.98 813 219 3.32 / 357.41 2 4
6 8 -0.04 170 15.01 296 755 4.08 / 358.17 2 5
Average= 4.02
(KJ/cycle)

Cycle 87 GMT 12/ 3/2022 5:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 30 14.95 493 221 0.22 / 350.17 2 3
2 12 1292.52 2 15.12 2239 68 0.29 / 350.24 2 3
3 7 2002.36 53 14.85 3080 2424 2.71 / 352.67 2 2
4 13 853.24 18 14.89 1542 413 3.13 / 353.08 2 3
5 13 401.24 18 14.97 898 242 3.37 / 353.32 2 4
6 8 0.16 170 15.03 302 772 4.14 / 354.09 2 3
Average= 4.02
(KJ/cycle)

Cycle 86 GMT 2/ 3/2022 7:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 30 14.95 491 220 0.22 / 346.11 2 3
2 12 1310.36 2 15.11 2259 68 0.29 / 346.18 2 2
3 7 2002.48 53 14.87 3084 2431 2.72 / 348.61 2 2
4 13 844.36 18 14.90 1518 407 3.13 / 349.02 2 5
5 13 268.68 18 15.01 715 193 3.32 / 349.21 2 4
6 8 -0.04 170 15.02 291 743 4.06 / 349.95 2 3
Average= 4.02
(KJ/cycle)

Cycle 85 GMT 20/ 2/2022 9:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 30 14.96 485 218 0.22 / 341.99 2 3
2 12 1328.96 2 15.12 2312 70 0.29 / 342.06 2 3
3 7 2003.16 52 14.86 3094 2391 2.68 / 344.45 2 2
4 13 981.80 18 14.86 1721 460 3.14 / 344.91 2 4
5 13 379.44 18 14.98 868 234 3.37 / 345.14 2 4
6 8 0.36 170 15.02 292 746 4.12 / 345.89 2 3
Average= 4.02
(KJ/cycle)

Cycle 84 GMT 10/ 2/2022 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 30 14.96 491 220 0.22 / 337.86 2 3
2 12 1297.24 2 15.14 2240 68 0.29 / 337.93 2 3
3 7 2003.36 53 14.86 3083 2428 2.72 / 340.36 2 3
4 13 858.96 18 14.89 1545 414 3.13 / 340.77 2 4
5 13 428.36 18 14.95 944 254 3.38 / 341.03 2 5
6 8 0.08 170 15.03 291 744 4.13 / 341.77 2 3
Average= 4.02
(KJ/cycle)

Cycle 83 GMT 31/ 1/2022 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 30 14.96 474 213 0.21 / 333.67 2 3
2 12 1306.12 2 15.12 2244 68 0.28 / 333.74 2 2
3 7 2003.08 53 14.89 3083 2433 2.71 / 336.17 2 3
4 13 864.72 18 14.89 1549 415 3.13 / 336.59 2 4
5 13 298.32 18 15.00 760 205 3.33 / 336.79 2 4
6 8 -0.16 170 15.03 290 741 4.07 / 337.53 2 3
7 14 -0.16 25 15.00 292 109 4.18 / 337.64 3 3
Average= 4.02
(KJ/cycle)

Cycle 82 GMT 21/ 1/2022 16: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 30 14.95 489 219 0.22 / 329.43 2 3
2 12 1311.00 2 15.14 2267 69 0.29 / 329.50 2 2
3 7 2001.04 53 14.87 3084 2431 2.72 / 331.93 2 3
4 13 965.60 18 14.88 1683 451 3.17 / 332.38 2 4
5 13 363.92 18 14.99 845 228 3.40 / 332.61 2 4
6 8 -0.04 170 15.04 289 739 4.14 / 333.35 2 2
7 14 -0.04 25 15.01 291 109 4.25 / 333.46 2 3
Average= 4.02
(KJ/cycle)

Cycle 81 GMT 11/ 1/2022 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 29 14.96 498 216 0.22 / 325.33 2 3
2 3 1016.92 1 15.07 1830 28 0.24 / 325.36 2 3
3 12 1307.80 2 15.11 2263 68 0.31 / 325.42 2 3
4 7 2001.28 53 14.86 3089 2433 2.74 / 327.86 2 3
5 13 854.84 18 14.87 1531 410 3.15 / 328.27 2 5
6 13 285.92 18 15.01 731 198 3.35 / 328.46 2 3
7 8 0.08 170 15.04 293 749 4.10 / 329.21 3 3
Average= 4.01
(KJ/cycle)

Cycle 80 GMT 1/ 1/2022 20: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 29 14.97 482 209 0.21 / 321.24 2 3
2 12 1322.88 2 15.13 2295 69 0.28 / 321.31 2 3
3 7 2002.80 53 14.87 3091 2436 2.71 / 323.75 2 3
4 13 859.08 18 14.89 1545 414 3.13 / 324.16 2 4
5 13 291.20 18 14.99 749 202 3.33 / 324.36 2 3
6 8 0.08 170 15.03 293 749 4.08 / 325.11 2 3
Average= 4.01
(KJ/cycle)

Cycle 79 GMT 22/12/2021 22:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 29 14.95 495 215 0.21 / 316.99 2 3
2 12 1319.48 2 15.13 2252 68 0.28 / 317.06 2 3
3 7 2003.60 53 14.89 3076 2427 2.71 / 319.49 2 2
4 13 968.80 18 14.87 1701 455 3.17 / 319.94 2 4
5 13 363.36 18 14.98 849 229 3.39 / 320.17 2 4
6 8 0.00 170 15.05 293 750 4.14 / 320.92 2 3
7 14 0.00 25 15.02 295 111 4.25 / 321.03 3 3
Average= 4.01
(KJ/cycle)

Cycle 78 GMT 13/12/2021 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 30 14.98 477 214 0.21 / 312.79 2 3
2 12 1305.32 2 15.12 2252 68 0.28 / 312.86 2 3
3 7 2002.84 53 14.87 3080 2427 2.71 / 315.28 2 2
4 13 969.76 18 14.87 1696 454 3.16 / 315.74 2 4
5 13 232.48 18 15.03 665 180 3.34 / 315.92 2 4
6 8 0.16 170 15.04 293 749 4.09 / 316.67 2 3
7 14 0.16 25 15.02 296 111 4.20 / 316.78 2 3
Average= 4.01
(KJ/cycle)

Cycle 77 GMT 3/12/2021 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 29 14.98 488 212 0.21 / 308.56 2 3
2 3 1027.12 1 15.04 1850 28 0.24 / 308.59 2 3
3 12 1276.00 2 15.14 2223 67 0.31 / 308.66 2 3
4 7 2002.92 52 14.90 3093 2396 2.70 / 311.05 2 3
5 13 847.44 18 14.92 1535 412 3.12 / 311.46 2 5
6 13 404.44 18 14.99 914 247 3.36 / 311.71 2 4
7 8 0.00 170 15.06 294 753 4.12 / 312.46 2 2
8 14 0.00 25 15.04 294 111 4.23 / 312.57 2 3
Average= 4.01
(KJ/cycle)

Cycle 76 GMT 23/11/2021 4: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 29 14.98 500 217 0.22 / 304.35 2 3
2 12 1311.72 2 15.13 2260 68 0.29 / 304.42 2 3
3 7 2001.08 53 14.90 3076 2429 2.71 / 306.85 2 3
4 13 950.48 18 14.89 1674 449 3.16 / 307.30 2 5
5 13 500.12 18 14.99 1040 281 3.44 / 307.58 2 5
6 8 0.08 170 15.06 301 771 4.21 / 308.35 2 2
Average= 4.00
(KJ/cycle)

Cycle 75 GMT 13/11/2021 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 14.99 479 208 0.21 / 300.20 2 3
2 12 1311.16 2 15.14 2275 69 0.28 / 300.26 2 2
3 7 2003.80 53 14.88 3082 2431 2.71 / 302.69 2 3
4 13 973.00 18 14.87 1710 458 3.17 / 303.15 2 3
5 13 367.52 18 15.01 866 234 3.40 / 303.39 2 3
6 8 0.32 170 15.06 292 748 4.15 / 304.13 2 3
Average= 4.00
(KJ/cycle)

Cycle 74 GMT 3/11/2021 8:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 29 14.99 491 213 0.21 / 296.06 2 3
2 12 1309.00 2 15.14 2251 68 0.28 / 296.13 2 2
3 7 2004.44 52 14.88 3078 2382 2.66 / 298.51 2 2
4 13 845.52 18 14.92 1527 410 3.07 / 298.92 2 4
5 13 266.32 18 15.03 720 195 3.27 / 299.12 2 4
6 8 -0.04 170 15.06 297 760 4.03 / 299.88 2 3
7 14 -0.04 25 15.03 296 111 4.14 / 299.99 2 3
Average= 4.00
(KJ/cycle)

Cycle 73 GMT 24/10/2021 10: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 29 14.99 499 217 0.22 / 291.98 2 3
2 12 1308.16 2 15.12 2249 68 0.28 / 292.05 2 3
3 7 2001.20 53 14.88 3082 2431 2.72 / 294.48 2 3
4 13 864.44 18 14.90 1557 418 3.13 / 294.90 2 4
5 13 279.12 18 15.03 732 198 3.33 / 295.10 2 4
6 8 0.36 170 15.05 293 750 4.08 / 295.85 2 2
Average= 4.00
(KJ/cycle)

Cycle 72 GMT 14/10/2021 12: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 14.99 474 206 0.21 / 287.89 2 3
2 3 1019.24 1 15.06 1848 28 0.23 / 287.92 2 4
3 12 1305.12 2 15.15 2258 68 0.30 / 287.98 2 3
4 7 2003.24 52 14.89 3092 2394 2.70 / 290.38 2 3
5 13 866.72 18 14.92 1560 419 3.12 / 290.80 2 5
6 13 293.48 18 15.04 754 204 3.32 / 291.00 2 4
7 8 -0.08 170 15.06 299 765 4.08 / 291.77 2 3
Average= 4.00
(KJ/cycle)

Cycle 71 GMT 4/10/2021 13:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 29 15.00 491 214 0.21 / 283.67 2 3
2 12 1318.32 2 15.11 2276 69 0.28 / 283.74 2 3
3 7 2002.08 53 14.88 3089 2436 2.72 / 286.18 2 2
4 13 959.12 18 14.90 1687 452 3.17 / 286.63 2 3
5 13 238.40 18 15.05 676 183 3.35 / 286.81 2 3
6 8 0.04 170 15.07 295 756 4.11 / 287.57 3 3
7 14 0.04 25 15.05 297 112 4.22 / 287.68 2 3
Average= 4.00
(KJ/cycle)

Cycle 70 GMT 24/ 9/2021 15:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 29 14.99 484 210 0.21 / 279.47 2 3
2 12 1315.04 2 15.15 2286 69 0.28 / 279.54 2 3
3 7 2003.48 53 14.89 3099 2446 2.73 / 281.98 2 3
4 13 844.68 18 14.92 1530 411 3.14 / 282.39 2 4
5 13 267.16 18 15.06 718 195 3.33 / 282.59 2 4
6 8 0.08 170 15.07 297 761 4.09 / 283.35 2 3
7 14 0.08 25 15.05 296 111 4.20 / 283.46 3 3
Average= 3.99
(KJ/cycle)

Cycle 69 GMT 14/ 9/2021 17:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 29 15.00 488 212 0.21 / 275.37 2 3
2 12 1312.64 2 15.13 2284 69 0.28 / 275.44 2 3
3 7 2003.24 53 14.90 3091 2441 2.72 / 277.88 2 3
4 13 866.28 18 14.93 1560 419 3.14 / 278.30 2 3
5 13 305.80 18 15.04 770 208 3.35 / 278.51 2 4
6 8 0.16 170 15.08 293 751 4.10 / 279.26 2 3
Average= 3.99
(KJ/cycle)

Cycle 68 GMT 4/ 9/2021 19:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 29 15.01 486 212 0.21 / 271.10 2 3
2 12 1311.72 2 15.13 2276 69 0.28 / 271.17 2 2
3 7 2002.84 53 14.87 3093 2438 2.72 / 273.61 2 3
4 13 972.92 18 14.89 1707 458 3.18 / 274.06 2 4
5 13 369.12 18 15.02 858 232 3.41 / 274.30 2 5
6 8 0.60 170 15.06 293 750 4.16 / 275.05 2 3
7 14 0.60 25 15.05 291 109 4.27 / 275.16 2 3
Average= 3.99
(KJ/cycle)

Cycle 67 GMT 25/ 8/2021 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 29 15.02 486 212 0.21 / 266.91 2 3
2 12 1159.76 2 15.19 2038 62 0.27 / 266.97 2 3
3 7 2003.40 53 14.89 3087 2436 2.71 / 269.40 2 3
4 13 967.20 18 14.89 1690 453 3.16 / 269.86 2 4
5 13 233.24 18 15.06 664 180 3.34 / 270.04 2 4
6 8 0.12 170 15.08 290 743 4.09 / 270.78 2 3
7 14 0.12 25 15.06 288 108 4.19 / 270.89 3 3
Average= 3.98
(KJ/cycle)

Cycle 66 GMT 15/ 8/2021 23:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 29 15.00 471 205 0.20 / 262.85 2 3
2 12 1301.28 2 15.14 2264 69 0.27 / 262.92 2 3
3 7 2002.04 52 14.89 3101 2401 2.67 / 265.32 2 3
4 13 966.84 18 14.90 1697 455 3.13 / 265.78 2 3
5 13 241.52 18 15.06 675 183 3.31 / 265.96 2 4
6 8 0.16 170 15.08 287 736 4.05 / 266.69 2 3
Average= 3.98
(KJ/cycle)

Cycle 65 GMT 6/ 8/2021 1: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 29 15.02 490 213 0.21 / 258.78 2 3
2 12 1322.40 2 15.14 2306 70 0.28 / 258.85 2 3
3 7 2004.20 53 14.89 3093 2441 2.72 / 261.29 2 3
4 13 858.36 18 14.92 1543 414 3.14 / 261.71 2 4
5 13 283.48 18 15.05 732 198 3.34 / 261.91 2 4
6 8 -0.32 170 15.06 289 740 4.08 / 262.65 2 3
Average= 3.98
(KJ/cycle)

Cycle 64 GMT 27/ 7/2021 2:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 29 15.01 481 209 0.21 / 254.78 2 3
2 12 1310.20 2 15.13 2262 68 0.28 / 254.84 2 2
3 7 2003.00 52 14.88 3076 2380 2.66 / 257.22 2 2
4 13 857.28 18 14.92 1545 415 3.07 / 257.64 2 3
5 13 276.16 18 15.06 724 196 3.27 / 257.84 2 4
6 8 0.32 170 15.08 286 733 4.00 / 258.57 2 2
Average= 3.98
(KJ/cycle)

Cycle 63 GMT 17/ 7/2021 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 29 15.02 470 205 0.20 / 250.51 2 3
2 12 1305.88 2 15.12 2250 68 0.27 / 250.58 2 2
3 7 2003.04 53 14.89 3092 2440 2.71 / 253.02 2 2
4 13 990.20 18 14.91 1735 466 3.18 / 253.48 2 3
5 13 373.64 18 15.03 858 232 3.41 / 253.71 2 4
6 8 -0.04 170 15.08 290 743 4.15 / 254.46 2 3
7 14 -0.04 25 15.05 290 109 4.26 / 254.57 2 3
Average= 3.98
(KJ/cycle)

Cycle 62 GMT 7/ 7/2021 6:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 29 15.01 484 211 0.21 / 246.33 2 3
2 12 1298.56 2 15.13 2243 68 0.28 / 246.40 2 2
3 7 2002.08 52 14.90 3100 2402 2.68 / 248.80 2 2
4 13 852.56 18 14.93 1538 413 3.09 / 249.21 2 4
5 13 407.48 18 15.02 913 247 3.34 / 249.46 2 4
6 8 -0.04 170 15.08 288 738 4.08 / 250.20 2 3
7 14 -0.04 25 15.06 286 108 4.19 / 250.30 2 3
Average= 3.97
(KJ/cycle)

Cycle 61 GMT 27/ 6/2021 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 15.04 467 204 0.20 / 242.16 2 3
2 12 1305.44 2 15.15 2266 69 0.27 / 242.23 2 3
3 7 2001.04 53 14.91 3088 2440 2.71 / 244.67 2 2
4 13 851.48 18 14.93 1534 412 3.12 / 245.08 2 3
5 13 274.00 18 15.06 724 196 3.32 / 245.28 2 4
6 8 0.16 170 15.08 285 731 4.05 / 246.01 2 3
7 14 0.16 25 15.05 285 107 4.16 / 246.12 2 3
Average= 3.97
(KJ/cycle)

Cycle 60 GMT 17/ 6/2021 10: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 29 15.03 489 213 0.21 / 238.00 2 3
2 12 1319.36 2 15.14 2280 69 0.28 / 238.07 2 2
3 7 2002.88 53 14.89 3090 2439 2.72 / 240.51 2 2
4 13 856.04 18 14.93 1540 414 3.13 / 240.92 2 3
5 13 274.32 18 15.06 720 195 3.33 / 241.12 2 3
6 8 -0.20 170 15.09 285 731 4.06 / 241.85 2 3
7 14 -0.20 25 15.08 285 107 4.17 / 241.96 2 3
Average= 3.97
(KJ/cycle)

Cycle 59 GMT 7/ 6/2021 11:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 29 15.04 482 210 0.21 / 233.89 2 3
2 12 1297.36 2 15.17 2251 68 0.28 / 233.96 2 3
3 7 2010.96 52 14.90 3098 2400 2.68 / 236.36 2 3
4 13 970.32 18 14.91 1700 456 3.14 / 236.82 2 4
5 13 364.68 18 15.04 848 230 3.36 / 237.05 2 4
6 8 0.16 170 15.08 289 741 4.11 / 237.79 3 3
Average= 3.96
(KJ/cycle)

Cycle 58 GMT 28/ 5/2021 13:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 29 15.05 480 209 0.21 / 229.84 2 3
2 12 1291.68 2 15.16 2219 67 0.28 / 229.91 2 3
3 7 2003.68 53 14.92 3081 2436 2.71 / 232.35 2 3
4 13 845.64 18 14.97 1524 411 3.12 / 232.76 2 4
5 13 273.84 18 15.07 713 193 3.32 / 232.95 2 4
6 8 0.48 170 15.10 286 734 4.05 / 233.68 2 3
Average= 3.96
(KJ/cycle)

Cycle 57 GMT 18/ 5/2021 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 15.05 461 201 0.20 / 225.87 2 3
2 12 1292.00 2 15.15 2222 67 0.27 / 225.94 2 3
3 7 2002.76 52 14.90 3096 2399 2.67 / 228.34 2 3
4 13 852.20 18 14.95 1536 413 3.08 / 228.75 2 4
5 13 157.08 18 15.12 552 150 3.23 / 228.90 2 3
6 8 -0.28 170 15.10 285 732 3.96 / 229.63 2 3
Average= 3.96
(KJ/cycle)

Cycle 56 GMT 8/ 5/2021 16:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 29 15.04 480 209 0.21 / 221.70 2 3
2 12 1297.96 2 15.15 2241 68 0.28 / 221.77 2 3
3 7 2002.64 53 14.92 3079 2435 2.71 / 224.20 2 3
4 13 868.76 18 14.96 1559 420 3.13 / 224.62 2 4
5 13 293.36 18 15.08 751 204 3.34 / 224.83 2 4
6 8 0.28 170 15.11 286 735 4.07 / 225.56 2 3
7 14 0.28 25 15.10 285 108 4.18 / 225.67 2 2
Average= 3.96
(KJ/cycle)

Cycle 55 GMT 28/ 4/2021 18:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 29 15.05 480 209 0.21 / 217.59 2 3
2 12 1294.56 2 15.14 2233 68 0.28 / 217.66 2 3
3 7 2002.00 53 14.91 3089 2441 2.72 / 220.10 2 3
4 13 979.28 18 14.92 1718 461 3.18 / 220.56 2 4
5 13 248.80 18 15.09 693 188 3.37 / 220.75 2 4
6 8 0.04 170 15.12 288 740 4.11 / 221.49 2 3
Average= 3.96
(KJ/cycle)

Cycle 54 GMT 18/ 4/2021 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 29 15.05 475 207 0.21 / 213.45 2 3
2 12 1313.08 2 15.18 2285 69 0.28 / 213.52 2 3
3 7 2003.64 53 14.89 3088 2437 2.71 / 215.96 2 3
4 13 971.96 18 14.92 1701 457 3.17 / 216.41 2 4
5 13 374.16 18 15.07 862 234 3.40 / 216.65 2 4
6 8 0.08 170 15.11 287 737 4.14 / 217.38 2 3
Average= 3.95
(KJ/cycle)

Cycle 53 GMT 8/ 4/2021 22: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 29 15.05 486 212 0.21 / 209.29 2 3
2 12 1304.48 2 15.18 2257 69 0.28 / 209.36 2 3
3 7 2001.80 53 14.91 3083 2436 2.72 / 211.80 2 3
4 13 851.84 18 14.96 1538 414 3.13 / 212.21 2 4
5 13 278.00 18 15.09 724 197 3.33 / 212.41 2 4
6 8 -0.12 170 15.12 283 727 4.06 / 213.14 2 3
7 14 -0.12 25 15.10 283 107 4.16 / 213.24 2 3
Average= 3.95
(KJ/cycle)

Cycle 52 GMT 29/ 3/2021 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 29 15.05 486 212 0.21 / 205.14 2 3
2 12 1301.60 2 15.17 2248 68 0.28 / 205.21 2 3
3 7 2001.92 53 14.93 3100 2453 2.73 / 207.66 2 3
4 13 963.40 18 14.96 1695 456 3.19 / 208.12 2 5
5 13 348.84 18 15.07 828 225 3.41 / 208.35 2 4
6 8 0.36 170 15.13 286 736 4.15 / 209.08 2 3
Average= 3.94
(KJ/cycle)

Cycle 51 GMT 20/ 3/2021 1:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 29 15.05 480 209 0.21 / 200.97 2 3
2 12 1292.96 2 15.18 2241 68 0.28 / 201.04 2 2
3 7 2003.04 53 14.93 3094 2448 2.73 / 203.48 2 2
4 13 847.60 18 14.99 1533 414 3.14 / 203.90 2 4
5 13 262.40 18 15.11 694 189 3.33 / 204.09 2 4
6 8 -0.04 170 15.14 286 736 4.06 / 204.82 2 3
7 14 -0.04 25 15.11 285 108 4.17 / 204.93 2 3
Average= 3.94
(KJ/cycle)

Cycle 50 GMT 10/ 3/2021 3:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 15.06 451 197 0.20 / 196.84 2 3
2 12 1284.20 2 15.18 2220 67 0.26 / 196.91 2 3
3 7 2002.80 53 14.93 3079 2436 2.70 / 199.34 2 3
4 13 962.84 18 14.95 1686 454 3.15 / 199.80 2 4
5 13 350.96 18 15.06 827 224 3.38 / 200.02 2 4
6 8 0.04 170 15.11 287 737 4.12 / 200.76 2 3
Average= 3.94
(KJ/cycle)

Cycle 49 GMT 28/ 2/2021 5:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 15.07 467 204 0.20 / 192.89 3 3
2 12 1303.92 2 15.19 2248 68 0.27 / 192.96 2 3
3 7 2002.40 52 14.93 3090 2399 2.67 / 195.36 2 3
4 13 838.88 18 14.98 1520 410 3.08 / 195.77 2 5
5 13 151.16 18 15.14 536 146 3.23 / 195.91 2 4
6 8 0.12 170 15.14 283 728 3.96 / 196.64 2 3
Average= 3.93
(KJ/cycle)

Cycle 48 GMT 18/ 2/2021 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 29 15.05 480 209 0.21 / 188.67 2 3
2 12 1303.60 2 15.19 2243 68 0.28 / 188.74 2 3
3 7 2003.36 53 14.92 3075 2432 2.71 / 191.17 2 3
4 13 968.72 18 14.95 1695 456 3.17 / 191.63 2 5
5 13 366.92 18 15.08 847 230 3.40 / 191.86 2 4
6 8 0.16 170 15.13 282 725 4.12 / 192.58 2 3
7 14 0.16 25 15.11 281 106 4.23 / 192.69 3 3
Average= 3.93
(KJ/cycle)

Cycle 47 GMT 8/ 2/2021 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 29 15.08 459 201 0.20 / 184.58 2 3
2 3 1016.56 1 15.13 1837 28 0.23 / 184.61 2 3
3 12 1302.00 2 15.18 2261 69 0.30 / 184.67 2 3
4 7 2003.00 53 14.93 3078 2436 2.73 / 187.11 2 3
5 13 860.32 18 14.99 1545 417 3.15 / 187.53 2 5
6 13 294.48 18 15.10 738 201 3.35 / 187.73 2 4
7 8 0.32 170 15.13 285 733 4.08 / 188.46 2 3
Average= 3.93
(KJ/cycle)

Cycle 46 GMT 29/ 1/2021 11:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 29 15.07 475 208 0.21 / 180.44 2 3
2 12 1317.20 2 15.18 2265 69 0.28 / 180.51 2 3
3 7 2002.28 52 14.94 3077 2390 2.67 / 182.90 2 3
4 13 981.84 18 14.95 1709 460 3.13 / 183.36 2 4
5 13 229.20 18 15.10 648 176 3.30 / 183.54 2 3
6 8 0.24 170 15.14 284 731 4.03 / 184.27 3 3
7 14 0.24 25 15.12 285 108 4.14 / 184.38 2 5
Average= 3.92
(KJ/cycle)

Cycle 45 GMT 19/ 1/2021 13:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 15.07 458 200 0.20 / 176.37 2 3
2 12 1308.12 2 15.18 2269 69 0.27 / 176.44 2 2
3 7 2003.40 53 14.95 3095 2452 2.72 / 178.89 2 2
4 13 852.40 18 14.98 1537 414 3.14 / 179.31 2 4
5 13 265.20 18 15.11 703 191 3.33 / 179.50 2 4
6 8 0.12 170 15.15 286 737 4.06 / 180.24 2 4
Average= 3.92
(KJ/cycle)

Cycle 44 GMT 9/ 1/2021 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 29 15.07 478 209 0.21 / 172.29 2 3
2 12 1281.68 2 15.17 2228 68 0.28 / 172.36 2 3
3 7 2001.80 53 14.92 3059 2419 2.70 / 174.78 2 2
4 13 847.40 18 14.97 1529 412 3.11 / 175.19 2 4
5 13 411.80 18 15.07 907 246 3.35 / 175.44 2 4
6 8 -0.32 170 15.14 285 734 4.09 / 176.17 2 3
Average= 3.91
(KJ/cycle)

Cycle 43 GMT 30/12/2020 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 29 15.07 471 206 0.21 / 168.23 2 3
2 12 1308.04 2 15.17 2266 69 0.27 / 168.30 2 3
3 7 2003.80 53 14.95 3103 2459 2.73 / 170.76 2 2
4 13 852.48 18 14.99 1523 411 3.14 / 171.17 2 4
5 13 265.68 18 15.12 696 189 3.33 / 171.36 2 4
6 8 0.16 170 15.14 283 728 4.06 / 172.09 2 3
Average= 3.91
(KJ/cycle)

Cycle 42 GMT 20/12/2020 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 29 15.08 479 209 0.21 / 164.12 2 3
2 12 1293.40 2 15.19 2230 68 0.28 / 164.19 2 2
3 7 2001.20 53 14.93 3090 2445 2.72 / 166.63 2 2
4 13 858.24 18 15.00 1538 415 3.14 / 167.05 2 4
5 13 411.16 18 15.08 912 248 3.39 / 167.30 2 5
6 8 0.40 170 15.14 282 726 4.11 / 168.02 2 3
Average= 3.91
(KJ/cycle)

Cycle 41 GMT 10/12/2020 20:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 30 15.07 481 217 0.22 / 160.11 2 3
2 12 1155.84 2 15.24 2034 62 0.28 / 160.17 2 3
3 7 2007.60 52 14.96 3091 2405 2.68 / 162.57 2 3
4 13 864.00 18 14.99 1539 415 3.10 / 162.99 2 4
5 13 292.60 18 15.13 731 199 3.30 / 163.19 2 4
6 8 0.00 170 15.14 282 726 4.02 / 163.91 2 3
Average= 3.90
(KJ/cycle)

Cycle 40 GMT 30/11/2020 22:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 30 15.09 469 212 0.21 / 156.02 2 3
2 12 1278.96 2 15.21 2198 67 0.28 / 156.09 2 3
3 7 2001.68 53 14.94 3083 2441 2.72 / 158.53 2 2
4 13 977.08 18 14.97 1700 458 3.18 / 158.99 2 3
5 13 233.96 18 15.14 649 177 3.36 / 159.16 2 4
6 8 0.08 170 15.15 281 724 4.08 / 159.89 3 3
Average= 3.90
(KJ/cycle)

Cycle 39 GMT 21/11/2020 0:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 29 15.10 458 201 0.20 / 151.93 3 3
2 12 1289.36 2 15.21 2226 68 0.27 / 152.00 2 3
3 7 2005.56 53 14.94 3090 2447 2.71 / 154.44 2 3
4 13 991.88 18 14.95 1717 462 3.18 / 154.90 2 5
5 13 243.08 18 15.14 666 181 3.36 / 155.09 2 3
6 8 -0.04 170 15.15 281 724 4.08 / 155.81 2 3
Average= 3.90
(KJ/cycle)

Cycle 38 GMT 11/11/2020 2:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 30 15.10 467 212 0.21 / 147.84 3 3
2 10 1000.20 2 15.10 1774 54 0.27 / 147.89 2 3
3 3 941.72 -1 15.42 4 0 0.05 / 147.89 2 3
4 12 1267.00 2 15.22 2173 66 0.33 / 147.96 2 3
5 7 2001.36 53 14.96 3066 2431 2.76 / 150.39 2 3
6 13 996.24 18 14.97 1712 461 3.22 / 150.85 2 3
7 13 246.76 18 15.14 655 179 3.40 / 151.03 2 4
8 8 0.04 170 15.15 272 701 4.10 / 151.73 3 3
Average= 3.89
(KJ/cycle)

Cycle 37 GMT 1/11/2020 5: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 30 15.11 463 210 0.21 / 143.73 3 3
2 12 1324.76 2 15.22 2258 69 0.28 / 143.80 2 3
3 7 2001.64 53 14.96 3079 2441 2.72 / 146.24 2 3
4 13 875.12 18 15.01 1546 418 3.14 / 146.66 2 4
5 13 155.88 18 15.15 528 144 3.28 / 146.80 2 3
6 8 0.64 170 15.15 278 716 4.00 / 147.52 3 3
7 14 0.64 25 15.14 276 104 4.10 / 147.62 3 3
Average= 3.88
(KJ/cycle)

Cycle 36 GMT 22/10/2020 7:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 30 15.09 476 215 0.22 / 139.70 3 3
2 12 1307.36 2 15.23 2236 68 0.28 / 139.77 2 3
3 7 2003.12 52 14.97 3085 2401 2.69 / 142.17 2 3
4 13 991.24 18 14.98 1710 461 3.15 / 142.63 2 4
5 13 248.92 18 15.13 665 181 3.33 / 142.81 2 3
6 8 0.04 170 15.17 276 712 4.04 / 143.52 3 3
Average= 3.88
(KJ/cycle)

Cycle 35 GMT 12/10/2020 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 30 15.11 455 206 0.21 / 135.50 3 3
2 12 1306.48 2 15.25 2250 69 0.27 / 135.57 2 3
3 7 2001.76 53 14.98 3084 2449 2.72 / 138.02 2 3
4 13 995.20 18 14.99 1719 464 3.19 / 138.48 2 3
5 13 252.00 18 15.14 668 182 3.37 / 138.66 3 3
6 8 -0.08 170 15.16 278 716 4.09 / 139.38 3 3
7 14 -0.08 25 15.15 275 104 4.19 / 139.48 3 3
Average= 3.87
(KJ/cycle)

Cycle 34 GMT 2/10/2020 11:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 15.11 446 202 0.20 / 131.42 3 3
2 12 1311.20 2 15.22 2238 68 0.27 / 131.49 2 3
3 7 2003.76 53 14.97 3071 2437 2.71 / 133.93 2 3
4 13 1001.76 18 14.99 1727 466 3.17 / 134.39 2 4
5 13 271.72 18 15.13 693 189 3.36 / 134.58 2 4
6 8 0.28 170 15.15 277 713 4.07 / 135.29 2 3
Average= 3.87
(KJ/cycle)

Cycle 33 GMT 22/ 9/2020 13:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 30 15.11 474 215 0.21 / 127.30 3 3
2 12 1312.72 2 15.23 2247 68 0.28 / 127.37 2 3
3 7 2007.20 52 14.98 3074 2395 2.68 / 129.77 2 3
4 13 990.76 18 14.98 1710 461 3.14 / 130.23 2 4
5 13 243.40 18 15.16 651 178 3.32 / 130.40 2 4
6 8 -0.08 170 15.17 275 709 4.03 / 131.11 3 4
7 14 -0.08 25 15.15 275 104 4.13 / 131.22 3 5
Average= 3.86
(KJ/cycle)

Cycle 32 GMT 12/ 9/2020 15:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.92 29 15.11 478 209 0.21 / 123.23 3 3
2 3 1019.00 1 15.18 1818 28 0.24 / 123.25 2 4
3 12 1147.04 2 15.28 1998 61 0.30 / 123.32 3 3
4 7 2003.72 53 14.98 3078 2444 2.74 / 125.76 2 3
5 13 886.56 18 15.01 1560 421 3.16 / 126.18 2 5
6 13 299.52 18 15.14 729 199 3.36 / 126.38 2 4
7 8 0.00 170 15.17 275 709 4.07 / 127.09 3 3
Average= 3.85
(KJ/cycle)

Cycle 31 GMT 2/ 9/2020 18: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 29 15.12 460 202 0.20 / 119.18 2 3
2 12 1326.00 2 15.23 2264 69 0.27 / 119.25 2 3
3 7 2006.08 53 14.98 3089 2452 2.72 / 121.70 2 3
4 13 879.48 18 15.04 1555 421 3.14 / 122.12 2 3
5 13 307.36 18 15.15 740 202 3.35 / 122.32 2 3
6 8 0.12 170 15.18 270 697 4.04 / 123.02 3 3
Average= 3.84
(KJ/cycle)

Cycle 30 GMT 23/ 8/2020 20:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 29 15.13 442 194 0.19 / 115.14 3 3
2 3 1022.36 1 15.18 1807 27 0.22 / 115.16 2 3
3 12 1301.04 2 15.25 2212 67 0.29 / 115.23 2 3
4 7 2004.92 52 14.99 3096 2413 2.70 / 117.65 2 3
5 13 988.28 18 15.00 1710 462 3.16 / 118.11 2 3
6 13 227.24 18 15.17 626 171 3.33 / 118.28 2 3
7 8 0.20 170 15.18 270 697 4.03 / 118.97 3 3
Average= 3.84
(KJ/cycle)

Cycle 29 GMT 13/ 8/2020 22:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 29 15.12 461 202 0.20 / 111.14 3 3
2 12 1316.08 2 15.24 2236 68 0.27 / 111.21 2 3
3 7 2004.28 53 14.99 3074 2442 2.71 / 113.65 2 3
4 13 859.40 18 15.03 1522 412 3.12 / 114.07 2 4
5 13 261.16 18 15.17 677 185 3.31 / 114.25 2 3
6 8 0.04 170 15.18 268 692 4.00 / 114.94 3 3
Average= 3.83
(KJ/cycle)

Cycle 28 GMT 4/ 8/2020 0:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 29 15.12 467 205 0.20 / 107.24 3 3
2 12 1310.48 2 15.23 2250 69 0.27 / 107.31 2 3
3 7 2003.56 52 14.97 3073 2392 2.67 / 109.70 2 3
4 13 848.04 18 15.03 1506 407 3.07 / 110.11 2 5
5 13 131.88 18 15.18 492 134 3.21 / 110.24 2 3
6 8 0.08 170 15.18 271 699 3.91 / 110.94 3 3
Average= 3.83
(KJ/cycle)

Cycle 27 GMT 25/ 7/2020 2:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 29 15.14 453 199 0.20 / 103.12 3 3
2 12 1299.28 2 15.26 2221 68 0.27 / 103.19 2 3
3 7 2001.68 53 14.98 3075 2441 2.71 / 105.63 2 3
4 13 854.80 18 15.04 1512 409 3.12 / 106.04 2 4
5 13 264.28 18 15.16 676 184 3.30 / 106.22 2 4
6 8 0.12 170 15.18 275 710 4.01 / 106.93 3 5
7 14 0.12 25 15.16 274 104 4.12 / 107.04 3 4
Average= 3.82
(KJ/cycle)

Cycle 26 GMT 15/ 7/2020 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 29 15.14 458 201 0.20 / 99.07 3 3
2 12 1147.56 2 15.28 1994 61 0.26 / 99.13 2 3
3 7 2001.92 53 14.99 3067 2437 2.70 / 101.57 2 3
4 13 857.08 18 15.05 1518 411 3.11 / 101.98 2 3
5 13 151.12 18 15.20 517 141 3.25 / 102.12 3 3
6 8 -0.08 170 15.19 270 697 3.95 / 102.82 3 4
7 14 -0.08 25 15.18 268 102 4.05 / 102.92 3 4
Average= 3.81
(KJ/cycle)

Cycle 25 GMT 5/ 7/2020 6:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 29 15.14 456 200 0.20 / 95.11 3 3
2 12 1302.76 2 15.25 2213 67 0.27 / 95.18 2 3
3 7 2004.04 53 15.00 3084 2452 2.72 / 97.63 2 3
4 13 844.76 18 15.07 1500 407 3.13 / 98.04 2 4
5 13 141.76 18 15.22 499 137 3.26 / 98.17 2 3
6 8 0.00 170 15.21 269 696 3.96 / 98.87 3 4
Average= 3.80
(KJ/cycle)

Cycle 24 GMT 25/ 6/2020 8:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 29 15.13 462 203 0.20 / 91.22 3 3
2 12 1322.80 2 15.26 2255 69 0.27 / 91.28 2 3
3 7 1937.52 52 15.01 2987 2331 2.60 / 93.62 2 3
4 13 934.36 18 15.05 1621 439 3.04 / 94.05 2 4
5 13 183.20 18 15.21 562 154 3.20 / 94.21 2 3
6 8 0.08 170 15.20 272 703 3.90 / 94.91 3 4
Average= 3.80
(KJ/cycle)

Cycle 23 GMT 15/ 6/2020 8:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 29 15.14 446 196 0.20 / 87.18 3 3
2 12 1148.84 2 15.29 1997 61 0.26 / 87.24 2 3
3 7 2001.00 54 15.00 3072 2488 2.75 / 89.72 2 3
4 13 856.12 18 15.05 1514 410 3.16 / 90.13 2 5
5 13 254.24 18 15.17 659 180 3.34 / 90.31 2 3
6 8 0.40 170 15.20 270 698 4.03 / 91.01 3 3
Average= 3.79
(KJ/cycle)

Cycle 22 GMT 5/ 6/2020 10:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 29 15.14 450 198 0.20 / 83.24 3 3
2 12 1309.72 2 15.25 2240 68 0.27 / 83.31 2 3
3 7 2001.76 52 14.98 3072 2393 2.66 / 85.71 2 3
4 13 973.72 18 15.04 1680 455 3.11 / 86.16 2 4
5 13 124.24 18 15.21 473 129 3.24 / 86.29 3 3
6 8 0.04 170 15.20 267 690 3.93 / 86.98 3 3
Average= 3.78
(KJ/cycle)

Cycle 21 GMT 26/ 5/2020 12:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 29 15.15 457 201 0.20 / 79.18 3 3
2 12 1311.52 2 15.24 2234 68 0.27 / 79.25 2 3
3 7 2006.32 52 15.00 3083 2405 2.67 / 81.65 2 3
4 13 873.76 18 15.06 1540 417 3.09 / 82.07 2 4
5 13 270.12 18 15.18 684 187 3.28 / 82.26 2 3
6 8 -0.16 170 15.19 267 689 3.97 / 82.95 3 3
7 14 -0.16 25 15.18 266 101 4.07 / 83.05 3 4
Average= 3.77
(KJ/cycle)

Cycle 20 GMT 16/ 5/2020 13:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 29 15.16 454 200 0.20 / 75.20 3 3
2 12 1306.16 2 15.25 2223 68 0.27 / 75.27 2 3
3 7 2002.64 52 15.01 3069 2395 2.66 / 77.66 2 3
4 13 984.40 18 15.04 1692 458 3.12 / 78.12 2 4
5 13 231.12 18 15.20 624 171 3.29 / 78.29 2 3
6 8 0.32 170 15.21 266 688 3.98 / 78.98 3 4
Average= 3.76
(KJ/cycle)

Cycle 19 GMT 6/ 5/2020 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 29 15.15 449 197 0.20 / 71.21 3 3
2 12 1157.28 2 15.31 2023 62 0.26 / 71.27 2 3
3 7 2002.04 53 15.02 3077 2449 2.71 / 73.72 2 3
4 13 844.64 18 15.06 1498 406 3.11 / 74.13 2 4
5 13 258.80 18 15.18 668 183 3.30 / 74.31 2 4
6 8 -0.04 170 15.21 267 690 3.99 / 75.00 3 3
Average= 3.75
(KJ/cycle)

Cycle 18 GMT 26/ 4/2020 17:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 29 15.15 451 198 0.20 / 67.25 3 3
2 12 1301.96 1 15.29 2216 34 0.23 / 67.28 2 3
3 7 2005.24 53 15.01 3075 2446 2.68 / 69.73 2 3
4 13 879.80 18 15.07 1546 419 3.10 / 70.15 2 3
5 13 290.24 18 15.18 714 195 3.29 / 70.34 2 4
6 8 0.32 165 15.21 266 668 3.96 / 71.01 3 3
Average= 3.74
(KJ/cycle)

Cycle 17 GMT 16/ 4/2020 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 29 15.16 457 201 0.20 / 63.01 3 3
2 12 1167.24 1 15.32 2021 31 0.23 / 63.04 2 3
3 7 2002.52 52 15.02 3073 2400 2.63 / 65.44 2 3
4 13 1004.60 18 15.04 1722 466 3.10 / 65.90 2 3
5 13 258.64 18 15.19 669 183 3.28 / 66.09 2 3
6 8 -0.08 165 15.22 266 668 3.95 / 66.75 3 3
7 14 -0.08 75 15.19 261 297 4.25 / 67.05 3 4
Average= 3.73
(KJ/cycle)

Cycle 16 GMT 6/ 4/2020 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 29 15.16 450 198 0.20 / 59.10 3 3
2 12 1164.12 1 15.34 2027 31 0.23 / 59.13 3 3
3 7 2004.72 53 15.03 3070 2446 2.67 / 61.58 2 3
4 13 872.20 18 15.07 1540 418 3.09 / 62.00 2 4
5 13 145.56 18 15.23 504 138 3.23 / 62.14 2 3
6 8 0.00 165 15.22 266 668 3.90 / 62.80 2 3
Average= 3.69
(KJ/cycle)

Cycle 15 GMT 28/ 3/2020 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 29 15.16 431 189 0.19 / 55.13 3 3
2 12 1310.68 1 15.31 2241 34 0.22 / 55.16 2 3
3 7 2002.84 53 15.02 3070 2444 2.67 / 57.61 2 3
4 13 995.28 18 15.06 1702 461 3.13 / 58.07 2 3
5 13 255.96 18 15.20 659 180 3.31 / 58.25 2 3
6 8 0.20 165 15.22 262 658 3.97 / 58.91 3 4
Average= 3.68
(KJ/cycle)

Cycle 14 GMT 18/ 3/2020 2:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 29 15.17 438 193 0.19 / 50.89 3 3
2 12 1309.36 1 15.31 2237 34 0.23 / 50.92 2 3
3 7 2005.12 52 15.03 3083 2410 2.64 / 53.33 2 3
4 13 996.52 18 15.06 1713 464 3.10 / 53.80 2 3
5 13 245.84 18 15.21 645 177 3.28 / 53.97 2 3
6 8 -0.12 165 15.22 265 665 3.94 / 54.64 3 3
7 14 -0.12 75 15.21 262 299 4.24 / 54.94 3 3
Average= 3.66
(KJ/cycle)

Cycle 13 GMT 8/ 3/2020 4:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 15.17 448 197 0.20 / 47.01 3 3
2 12 1308.52 1 15.32 2231 34 0.23 / 47.04 2 3
3 7 2003.32 53 15.03 3054 2433 2.66 / 49.47 2 3
4 13 867.40 18 15.08 1529 415 3.08 / 49.89 2 4
5 13 162.20 18 15.22 526 144 3.22 / 50.03 2 3
6 8 -0.08 165 15.22 265 665 3.89 / 50.70 3 5
Average= 3.62
(KJ/cycle)

Cycle 12 GMT 27/ 2/2020 7:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 29 15.17 446 196 0.20 / 43.02 3 3
2 12 1300.60 1 15.31 2234 34 0.23 / 43.06 3 3
3 7 2005.64 53 15.03 3069 2445 2.68 / 45.50 2 3
4 13 996.44 18 15.05 1703 461 3.14 / 45.96 2 3
5 13 244.52 18 15.22 641 176 3.31 / 46.14 3 3
6 8 0.12 165 15.23 266 668 3.98 / 46.81 3 3
Average= 3.60
(KJ/cycle)

Cycle 11 GMT 17/ 2/2020 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 29 15.18 458 202 0.20 / 39.12 3 3
2 12 1313.20 1 15.30 2253 34 0.24 / 39.16 3 3
3 7 2002.52 53 15.04 3066 2444 2.68 / 41.60 2 3
4 13 868.24 18 15.09 1530 416 3.10 / 42.02 2 4
5 13 164.96 18 15.24 531 146 3.24 / 42.16 3 3
6 8 0.20 165 15.23 265 666 3.91 / 42.83 3 3
Average= 3.57
(KJ/cycle)

Cycle 10 GMT 7/ 2/2020 11:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 28 15.19 436 185 0.19 / 35.12 3 3
2 3 1017.68 1 15.23 1825 28 0.21 / 35.15 2 3
3 12 1299.68 1 15.32 2212 34 0.25 / 35.19 2 3
4 7 2005.32 53 15.03 3056 2434 2.68 / 37.62 2 3
5 13 985.12 18 15.07 1695 460 3.14 / 38.08 2 3
6 13 236.80 18 15.22 634 174 3.31 / 38.25 2 3
7 8 0.12 165 15.24 265 666 3.98 / 38.92 3 3
Average= 3.54
(KJ/cycle)

Cycle 9 GMT 28/ 1/2020 13:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 28 15.18 445 189 0.19 / 31.17 3 3
2 12 1307.80 1 15.31 2224 34 0.22 / 31.21 2 3
3 7 2002.96 53 15.05 3078 2455 2.68 / 33.66 2 3
4 13 975.92 18 15.08 1679 456 3.13 / 34.12 2 3
5 13 220.20 18 15.23 606 166 3.30 / 34.28 2 3
6 8 0.00 165 15.24 261 656 3.96 / 34.94 3 3
Average= 3.49
(KJ/cycle)

Cycle 8 GMT 18/ 1/2020 16:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 28 15.19 445 189 0.19 / 27.22 3 3
2 12 1315.80 1 15.30 2245 34 0.22 / 27.26 2 3
3 7 2001.96 53 15.05 3072 2450 2.67 / 29.71 2 3
4 13 981.44 18 15.08 1687 458 3.13 / 30.16 2 3
5 13 216.92 18 15.22 602 165 3.30 / 30.33 2 3
6 8 0.20 165 15.24 260 654 3.95 / 30.98 3 3
Average= 3.44
(KJ/cycle)

Cycle 7 GMT 8/ 1/2020 18:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 28 15.18 448 190 0.19 / 23.28 3 3
2 12 1312.88 1 15.30 2233 34 0.22 / 23.32 2 3
3 7 2001.52 53 15.04 3066 2444 2.67 / 25.76 2 3
4 13 978.24 18 15.06 1680 455 3.12 / 26.21 2 3
5 13 202.44 18 15.23 584 160 3.28 / 26.38 2 3
6 8 0.08 165 15.25 261 657 3.94 / 27.03 3 3
Average= 3.38
(KJ/cycle)

Cycle 6 GMT 29/12/2019 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 28 15.18 438 186 0.19 / 19.41 3 3
2 7 2007.04 52 15.05 3073 2405 2.59 / 21.82 2 3
3 13 871.52 18 15.12 1526 415 3.01 / 22.23 2 3
4 13 294.20 18 15.23 711 195 3.20 / 22.43 2 4
5 8 -0.04 165 15.25 264 664 3.87 / 23.09 3 3
Average= 3.30
(KJ/cycle)

Cycle 5 GMT 19/12/2019 23:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 25 15.19 445 169 0.17 / 15.00 3 3
2 10 1007.64 3 15.18 1765 80 0.25 / 15.08 3 3
3 7 2003.36 74 14.79 3030 3316 3.57 / 18.39 2 3
4 13 213.00 18 15.23 599 164 3.73 / 18.56 3 3
5 8 0.00 165 15.24 265 666 4.40 / 19.23 3 4
Average= 3.20
(KJ/cycle)

Cycle 4 GMT 10/12/2019 2: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 27 15.20 442 181 0.18 / 11.45 3 3
2 7 1529.52 74 14.94 2384 2636 2.82 / 14.09 2 3
3 13 29.68 18 15.27 308 85 2.90 / 14.17 2 3
4 8 0.08 165 15.26 260 655 3.56 / 14.83 3 3
Average= 2.97
(KJ/cycle)

Cycle 3 GMT 9/12/2019 2:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 27 15.20 441 181 0.18 / 7.88 3 3
2 3 1017.12 1 15.24 1814 28 0.21 / 7.91 2 3
3 7 1523.16 74 14.93 2373 2622 2.83 / 10.53 2 3
4 13 48.64 18 15.27 335 92 2.92 / 10.62 2 3
5 8 -0.08 165 15.24 258 649 3.57 / 11.27 2 3
Average= 2.82
(KJ/cycle)

Cycle 2 GMT 8/12/2019 2:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 26 15.23 435 172 0.17 / 4.35 2 3
2 3 1027.12 1 15.24 1808 28 0.20 / 4.38 2 3
3 7 1508.72 74 14.95 2347 2596 2.80 / 6.98 2 3
4 13 27.16 18 15.28 297 82 2.88 / 7.06 3 3
5 8 0.16 165 15.25 255 642 3.52 / 7.70 3 3
Average= 2.57
(KJ/cycle)

Cycle 1 GMT 7/12/2019 3:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 23 15.39 398 141 0.14 / 1.57 3 3
2 10 1028.68 3 15.23 1786 82 0.22 / 1.65 3 3
3 3 1044.60 1 15.23 1816 28 0.25 / 1.68 2 3
4 7 998.12 74 15.11 1650 1845 2.10 / 3.53 3 4
5 8 0.04 165 15.29 260 656 2.75 / 4.18 3 4
Average= 2.09
(KJ/cycle)

Cycle 0 GMT 6/12/2019 17: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 91.36 22 15.52 380 130 0.13 / 0.13 3 3
2 7 104.40 74 15.49 387 444 0.57 / 0.57 3 3
3 8 0.12 240 15.47 231 858 1.43 / 1.43 3 11
Average= 1.43
(KJ/cycle)