SIO Argo Site:
Pump Diagnostics Page   



Serial= 8751 WMO= 5905783

Return

←PreviousNext→

Cycle 215 GMT 7/10/2024 13:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.08 29 15.05 636 278 0.28 / 958.40 2 2
2 7 2002.80 30 15.04 2951 1331 1.61 / 959.73 2 2
3 13 1587.64 29 14.99 2454 1067 2.68 / 960.79 2 3
4 13 686.96 29 15.05 1322 577 3.25 / 961.37 2 3
5 13 54.60 5 15.18 507 38 3.29 / 961.41 2 4
6 8 -0.04 175 15.13 395 1046 4.34 / 962.46 2 15
Average= 4.46
(KJ/cycle)

Cycle 214 GMT 27/ 9/2024 15:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.04 29 15.05 641 280 0.28 / 953.94 2 2
2 7 2003.24 30 15.04 2971 1341 1.62 / 955.28 2 2
3 13 1600.84 29 15.00 2460 1070 2.69 / 956.35 2 3
4 13 660.52 29 15.06 1285 561 3.25 / 956.91 2 4
5 13 53.08 5 15.18 504 38 3.29 / 956.95 2 4
6 8 0.08 175 15.13 396 1049 4.34 / 958.00 2 12
7 14 0.08 20 15.11 396 120 4.46 / 958.12 2 11
Average= 4.46
(KJ/cycle)

Cycle 213 GMT 17/ 9/2024 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.12 29 15.04 636 277 0.28 / 949.52 2 2
2 7 2006.04 30 15.05 2976 1344 1.62 / 950.86 2 2
3 13 1595.00 29 15.00 2456 1068 2.69 / 951.93 2 4
4 13 662.96 29 15.06 1291 564 3.25 / 952.50 2 4
5 8 0.16 175 15.14 394 1044 4.30 / 953.54 2 14
6 14 0.16 20 15.11 398 120 4.42 / 953.66 2 14
Average= 4.46
(KJ/cycle)

Cycle 212 GMT 7/ 9/2024 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.28 29 15.06 620 271 0.27 / 944.98 2 2
2 7 2003.56 30 15.05 2960 1336 1.61 / 946.31 2 2
3 13 1591.16 29 14.99 2469 1073 2.68 / 947.39 2 4
4 13 671.84 29 15.06 1293 565 3.25 / 947.95 2 4
5 13 62.00 6 15.18 510 46 3.29 / 948.00 2 4
6 13 53.16 5 15.18 506 38 3.33 / 948.04 2 5
7 13 47.64 5 15.18 503 38 3.37 / 948.07 2 5
8 8 0.16 175 15.13 396 1049 4.42 / 949.12 2 16
9 14 0.16 20 15.10 399 120 4.54 / 949.24 2 14
Average= 4.46
(KJ/cycle)

Cycle 211 GMT 28/ 8/2024 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.76 29 15.06 621 271 0.27 / 940.63 2 2
2 7 2002.60 30 15.04 2955 1333 1.60 / 941.96 2 2
3 13 1584.52 29 15.00 2461 1071 2.68 / 943.03 2 4
4 13 788.52 29 15.04 1453 634 3.31 / 943.67 2 4
5 8 0.08 175 15.14 392 1039 4.35 / 944.71 2 13
Average= 4.46
(KJ/cycle)

Cycle 210 GMT 18/ 8/2024 23:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.40 29 15.06 616 269 0.27 / 936.26 2 2
2 7 2005.12 30 15.05 2965 1339 1.61 / 937.60 2 2
3 13 1609.64 29 15.00 2478 1078 2.69 / 938.68 2 4
4 13 689.52 29 15.06 1330 581 3.27 / 939.26 2 4
5 13 54.48 5 15.19 501 38 3.30 / 939.30 2 4
6 8 0.48 175 15.13 400 1059 4.36 / 940.36 2 15
Average= 4.46
(KJ/cycle)

Cycle 209 GMT 9/ 8/2024 2: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.12 29 15.06 614 268 0.27 / 931.74 2 2
2 7 2004.84 30 15.06 2958 1336 1.60 / 933.08 2 2
3 13 1607.48 29 15.00 2474 1076 2.68 / 934.15 2 3
4 13 803.52 29 15.04 1473 642 3.32 / 934.79 2 5
5 13 49.40 5 15.19 489 37 3.36 / 934.83 2 4
6 8 -0.12 175 15.14 394 1044 4.40 / 935.88 2 14
7 14 -0.12 20 15.11 394 119 4.52 / 935.99 2 13
Average= 4.46
(KJ/cycle)

Cycle 208 GMT 30/ 7/2024 4:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.44 29 15.05 640 279 0.28 / 927.46 2 2
2 7 2002.28 30 15.05 2954 1334 1.61 / 928.79 2 2
3 13 1591.08 29 15.00 2456 1068 2.68 / 929.86 2 5
4 13 662.88 29 15.06 1302 569 3.25 / 930.43 2 4
5 8 0.28 175 15.14 393 1041 4.29 / 931.47 2 14
Average= 4.46
(KJ/cycle)

Cycle 207 GMT 20/ 7/2024 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.32 29 15.07 622 272 0.27 / 922.87 2 2
2 7 2007.24 30 15.05 2964 1338 1.61 / 924.21 2 2
3 13 1734.72 29 14.98 2640 1147 2.76 / 925.36 2 3
4 13 643.48 29 15.07 1276 558 3.31 / 925.92 2 4
5 13 68.40 29 15.16 507 223 3.54 / 926.14 2 6
6 8 -0.12 175 15.13 393 1041 4.58 / 927.18 2 15
Average= 4.46
(KJ/cycle)

Cycle 206 GMT 10/ 7/2024 8:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 170.20 29 15.05 649 283 0.28 / 918.45 2 2
2 7 2004.84 31 15.05 2947 1375 1.66 / 919.83 2 2
3 13 1601.72 29 15.00 2476 1077 2.74 / 920.91 2 3
4 13 787.32 29 15.05 1456 635 3.37 / 921.54 2 4
5 8 0.64 175 15.14 400 1060 4.43 / 922.60 2 15
Average= 4.46
(KJ/cycle)

Cycle 205 GMT 30/ 6/2024 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.76 29 15.06 612 267 0.27 / 913.91 2 2
2 7 2010.64 30 15.06 2960 1337 1.60 / 915.24 2 2
3 13 1596.80 29 15.00 2474 1076 2.68 / 916.32 2 3
4 13 665.36 29 15.07 1298 567 3.25 / 916.89 2 4
5 13 82.12 29 15.16 530 233 3.48 / 917.12 2 6
6 8 -0.20 175 15.13 397 1051 4.53 / 918.17 2 14
Average= 4.46
(KJ/cycle)

Cycle 204 GMT 20/ 6/2024 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.96 29 15.06 629 275 0.27 / 909.48 2 2
2 7 2008.08 31 15.05 2953 1378 1.65 / 910.86 2 2
3 13 1468.00 29 15.02 2314 1008 2.66 / 911.86 2 4
4 13 575.48 29 15.08 1196 523 3.18 / 912.39 2 4
5 13 53.00 29 15.17 485 213 3.40 / 912.60 2 5
6 8 0.20 175 15.13 392 1038 4.43 / 913.64 2 14
Average= 4.46
(KJ/cycle)

Cycle 203 GMT 10/ 6/2024 15:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.00 29 15.06 623 272 0.27 / 904.86 2 3
2 7 2002.76 30 15.05 2944 1329 1.60 / 906.19 2 2
3 13 1725.96 29 14.99 2628 1142 2.74 / 907.33 2 2
4 13 756.32 29 15.05 1417 618 3.36 / 907.95 2 6
5 13 58.84 29 15.17 497 219 3.58 / 908.17 2 5
6 8 -0.08 175 15.13 390 1033 4.61 / 909.20 2 14
Average= 4.46
(KJ/cycle)

Cycle 202 GMT 31/ 5/2024 17:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.88 29 15.05 648 283 0.28 / 900.12 2 3
2 7 2004.68 30 15.06 2959 1337 1.62 / 901.46 2 3
3 13 1725.84 29 15.00 2625 1142 2.76 / 902.60 2 4
4 13 757.80 29 15.05 1423 621 3.38 / 903.22 2 6
5 13 49.84 29 15.18 487 214 3.60 / 903.43 2 6
6 8 0.00 175 15.14 392 1039 4.64 / 904.47 2 14
7 14 0.00 20 15.11 389 118 4.75 / 904.59 2 14
Average= 4.46
(KJ/cycle)

Cycle 201 GMT 21/ 5/2024 19:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.84 29 15.06 613 268 0.27 / 895.41 2 2
2 7 2003.60 31 15.05 2947 1375 1.64 / 896.79 2 2
3 13 1586.52 29 15.01 2462 1072 2.71 / 897.86 2 3
4 13 680.24 29 15.06 1332 582 3.30 / 898.44 2 5
5 13 81.76 29 15.16 535 235 3.53 / 898.67 2 6
6 8 0.40 175 15.13 394 1043 4.57 / 899.72 2 12
7 14 0.40 20 15.10 398 120 4.69 / 899.84 2 16
Average= 4.45
(KJ/cycle)

Cycle 200 GMT 11/ 5/2024 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.16 29 15.06 645 282 0.28 / 890.77 2 3
2 7 2004.92 30 15.05 2964 1338 1.62 / 892.11 2 2
3 13 1603.36 29 15.00 2482 1080 2.70 / 893.18 2 3
4 13 662.24 29 15.06 1306 570 3.27 / 893.76 2 4
5 13 76.24 29 15.16 525 231 3.50 / 893.99 2 5
6 8 0.08 175 15.13 392 1038 4.54 / 895.02 2 9
7 14 0.08 20 15.10 393 119 4.66 / 895.14 2 15
Average= 4.45
(KJ/cycle)

Cycle 199 GMT 1/ 5/2024 23:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.80 29 15.06 615 269 0.27 / 886.21 2 2
2 7 2006.24 30 15.06 2962 1338 1.61 / 887.54 2 2
3 13 1616.08 29 15.00 2490 1083 2.69 / 888.63 2 5
4 13 731.72 29 15.05 1386 605 3.29 / 889.23 2 4
5 13 53.20 29 15.17 488 215 3.51 / 889.45 2 6
6 8 0.28 175 15.13 392 1038 4.55 / 890.49 2 14
Average= 4.45
(KJ/cycle)

Cycle 198 GMT 22/ 4/2024 1:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.12 29 15.06 617 269 0.27 / 881.68 2 2
2 7 2010.20 30 15.05 2973 1342 1.61 / 883.02 2 2
3 13 1614.80 29 15.00 2484 1081 2.69 / 884.11 2 4
4 13 695.92 29 15.06 1344 587 3.28 / 884.69 2 5
5 13 37.32 29 15.18 472 208 3.49 / 884.90 2 6
6 8 -0.32 175 15.13 392 1038 4.52 / 885.94 2 16
Average= 4.45
(KJ/cycle)

Cycle 197 GMT 12/ 4/2024 4:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.92 29 15.06 648 283 0.28 / 877.11 2 2
2 3 985.48 -1 15.51 7 0 0.00 / 877.11 2 2
3 7 2007.76 30 15.06 2980 1346 1.63 / 878.46 2 2
4 13 1605.24 29 14.99 2492 1083 2.71 / 879.54 2 3
5 13 694.00 29 15.06 1343 587 3.30 / 880.13 2 5
6 13 88.44 29 15.16 545 240 3.54 / 880.37 2 5
7 8 -0.04 175 15.13 395 1046 4.58 / 881.41 2 15
Average= 4.45
(KJ/cycle)

Cycle 196 GMT 2/ 4/2024 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.20 29 15.08 619 271 0.27 / 872.50 2 2
2 7 2008.92 30 15.05 2960 1336 1.61 / 873.83 2 2
3 13 1589.32 29 15.00 2462 1071 2.68 / 874.90 2 3
4 13 638.88 29 15.08 1267 554 3.23 / 875.46 2 4
5 13 31.32 29 15.18 462 203 3.44 / 875.66 2 6
6 8 0.24 175 15.14 395 1047 4.48 / 876.71 2 16
7 14 0.24 20 15.11 396 120 4.60 / 876.83 2 13
Average= 4.45
(KJ/cycle)

Cycle 195 GMT 23/ 3/2024 8:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.56 28 15.07 623 263 0.26 / 867.94 2 2
2 3 1016.00 1 15.21 1835 28 0.29 / 867.97 2 2
3 7 2002.40 30 15.05 2955 1334 1.62 / 869.30 2 2
4 13 1593.92 29 15.01 2459 1070 2.70 / 870.37 2 4
5 13 780.72 29 15.06 1437 628 3.32 / 871.00 2 5
6 13 56.04 29 15.18 489 215 3.54 / 871.21 2 5
7 8 -0.04 175 15.14 382 1012 4.55 / 872.23 2 15
Average= 4.45
(KJ/cycle)

Cycle 194 GMT 13/ 3/2024 10:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.24 28 15.06 644 272 0.27 / 863.40 2 2
2 7 2003.96 30 15.05 2960 1336 1.61 / 864.74 2 2
3 13 1728.60 29 14.99 2640 1148 2.76 / 865.89 2 4
4 13 656.48 29 15.07 1291 564 3.32 / 866.45 2 5
5 13 39.80 29 15.18 467 206 3.53 / 866.66 2 6
6 8 0.16 175 15.14 384 1017 4.54 / 867.68 2 14
Average= 4.45
(KJ/cycle)

Cycle 193 GMT 3/ 3/2024 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.04 29 15.06 620 271 0.27 / 858.88 2 2
2 7 2002.68 30 15.05 2950 1332 1.60 / 860.21 2 2
3 13 1591.68 29 15.00 2456 1068 2.67 / 861.28 2 5
4 13 671.32 29 15.07 1314 574 3.25 / 861.85 2 3
5 13 73.72 29 15.17 524 231 3.48 / 862.08 2 6
6 8 -0.08 175 15.13 396 1049 4.52 / 863.13 2 15
Average= 4.45
(KJ/cycle)

Cycle 192 GMT 22/ 2/2024 15:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.24 29 15.07 627 274 0.27 / 854.47 2 2
2 7 2007.96 30 15.04 2971 1341 1.61 / 855.81 2 2
3 13 1468.44 29 15.01 2325 1012 2.63 / 856.82 2 6
4 13 580.68 29 15.08 1202 526 3.15 / 857.35 2 5
5 13 48.64 29 15.18 489 215 3.37 / 857.56 2 6
6 8 0.00 175 15.14 394 1044 4.41 / 858.61 2 19
Average= 4.45
(KJ/cycle)

Cycle 191 GMT 12/ 2/2024 17:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 170.60 29 15.07 640 280 0.28 / 849.87 2 2
2 7 2003.72 30 15.07 2958 1337 1.62 / 851.20 2 2
3 13 1604.60 29 15.01 2479 1079 2.70 / 852.28 2 3
4 13 795.20 29 15.05 1477 645 3.34 / 852.93 2 6
5 13 53.52 29 15.18 493 217 3.56 / 853.15 2 5
6 8 0.04 175 15.14 397 1052 4.61 / 854.20 2 15
Average= 4.45
(KJ/cycle)

Cycle 190 GMT 2/ 2/2024 19:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.00 29 15.07 630 275 0.28 / 845.38 2 2
2 3 984.48 -1 15.52 8 0 0.00 / 845.38 2 2
3 7 2002.76 30 15.06 2966 1340 1.62 / 846.72 2 3
4 13 1576.32 29 15.01 2451 1067 2.68 / 847.78 2 3
5 13 653.44 29 15.08 1292 565 3.25 / 848.35 2 5
6 13 62.24 29 15.18 511 225 3.47 / 848.57 2 6
7 8 0.28 175 15.14 383 1015 4.49 / 849.59 2 14
Average= 4.45
(KJ/cycle)

Cycle 189 GMT 23/ 1/2024 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.28 29 15.07 640 280 0.28 / 840.69 2 2
2 7 2003.52 30 15.07 2968 1342 1.62 / 842.03 2 3
3 13 1592.88 29 15.01 2475 1077 2.70 / 843.11 2 3
4 13 778.52 29 15.06 1452 634 3.33 / 843.74 2 7
5 13 53.24 29 15.19 492 217 3.55 / 843.96 2 6
6 8 0.20 175 15.15 386 1023 4.57 / 844.98 2 18
7 14 0.20 20 15.12 392 119 4.69 / 845.10 2 12
Average= 4.45
(KJ/cycle)

Cycle 188 GMT 14/ 1/2024 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.64 29 15.07 640 280 0.28 / 836.01 2 2
2 7 2003.44 30 15.06 2963 1339 1.62 / 837.34 2 2
3 13 1610.60 29 15.00 2496 1086 2.70 / 838.43 2 6
4 13 681.56 29 15.07 1328 580 3.28 / 839.01 2 4
5 13 80.28 29 15.17 536 236 3.52 / 839.25 2 6
6 8 0.00 175 15.14 394 1044 4.56 / 840.29 2 10
7 14 0.00 20 15.12 395 119 4.68 / 840.41 2 16
Average= 4.45
(KJ/cycle)

Cycle 187 GMT 4/ 1/2024 2:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.12 29 15.07 646 282 0.28 / 831.46 2 2
2 7 2004.72 30 15.06 2956 1336 1.62 / 832.79 2 2
3 13 1596.04 29 15.01 2477 1078 2.70 / 833.87 2 3
4 13 662.64 29 15.08 1301 569 3.27 / 834.44 2 5
5 13 66.24 29 15.18 519 228 3.49 / 834.67 2 5
6 8 0.16 175 15.14 399 1057 4.55 / 835.73 2 18
Average= 4.45
(KJ/cycle)

Cycle 186 GMT 25/12/2023 4:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.96 29 15.07 649 284 0.28 / 826.85 2 2
2 7 2008.16 30 15.06 2969 1341 1.63 / 828.20 2 2
3 13 1598.28 29 15.00 2475 1077 2.70 / 829.27 2 3
4 13 796.56 29 15.05 1479 646 3.35 / 829.92 2 6
5 13 54.36 29 15.18 501 221 3.57 / 830.14 2 5
6 8 -0.24 175 15.15 391 1037 4.60 / 831.17 2 14
Average= 4.44
(KJ/cycle)

Cycle 185 GMT 15/12/2023 6:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.36 29 15.07 648 283 0.28 / 822.19 2 2
2 10 1011.20 2 15.09 1822 55 0.34 / 822.24 2 2
3 3 954.24 -2 15.49 8 0 0.05 / 822.24 2 2
4 7 2001.84 30 15.06 2973 1343 1.68 / 823.58 2 2
5 13 1599.12 29 15.01 2480 1080 2.76 / 824.66 2 3
6 13 787.60 29 15.05 1465 639 3.40 / 825.30 2 5
7 13 51.12 29 15.19 499 220 3.62 / 825.52 2 6
8 8 0.36 175 15.15 395 1047 4.67 / 826.57 2 13
Average= 4.44
(KJ/cycle)

Cycle 184 GMT 5/12/2023 8:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.00 29 15.07 653 285 0.29 / 817.53 2 2
2 7 2007.32 30 15.05 2983 1347 1.63 / 818.88 2 2
3 13 1605.00 29 15.00 2497 1086 2.72 / 819.97 2 3
4 13 819.68 29 15.05 1506 657 3.38 / 820.62 2 5
5 13 62.08 29 15.18 521 229 3.61 / 820.85 2 6
6 8 0.12 175 15.14 396 1049 4.65 / 821.90 2 14
Average= 4.44
(KJ/cycle)

Cycle 183 GMT 25/11/2023 10:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.64 29 15.08 629 275 0.28 / 813.03 2 2
2 7 2003.12 30 15.06 2976 1345 1.62 / 814.37 2 2
3 13 1477.60 29 15.02 2331 1015 2.63 / 815.39 2 3
4 13 699.68 29 15.07 1347 589 3.22 / 815.98 2 4
5 13 42.96 29 15.18 492 217 3.44 / 816.19 2 5
6 8 0.20 175 15.14 399 1057 4.50 / 817.25 2 15
Average= 4.44
(KJ/cycle)

Cycle 182 GMT 15/11/2023 12:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.76 29 15.07 627 274 0.27 / 808.65 2 2
2 7 2011.44 31 15.05 2975 1388 1.66 / 810.03 2 2
3 13 1601.48 29 15.00 2484 1081 2.74 / 811.12 2 3
4 13 657.92 29 15.08 1303 570 3.31 / 811.68 2 4
5 8 -0.16 175 15.16 402 1067 4.38 / 812.75 2 14
Average= 4.44
(KJ/cycle)

Cycle 181 GMT 5/11/2023 14:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.24 29 15.08 634 277 0.28 / 803.97 2 3
2 7 2004.12 30 15.07 2969 1342 1.62 / 805.32 2 2
3 13 1730.80 29 15.00 2640 1148 2.77 / 806.46 2 3
4 13 744.84 29 15.07 1417 619 3.39 / 807.08 2 4
5 13 51.60 29 15.18 504 222 3.61 / 807.30 2 6
6 8 0.20 175 15.14 403 1068 4.68 / 808.37 2 15
Average= 4.44
(KJ/cycle)

Cycle 180 GMT 26/10/2023 17:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.48 29 15.06 653 285 0.29 / 799.64 2 3
2 7 2006.48 30 15.05 2966 1339 1.62 / 800.98 2 2
3 13 1579.52 29 15.01 2465 1073 2.70 / 802.06 2 3
4 13 638.04 29 15.08 1287 563 3.26 / 802.62 2 4
5 8 0.08 175 15.16 406 1077 4.34 / 803.70 2 10
Average= 4.44
(KJ/cycle)

Cycle 179 GMT 16/10/2023 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.16 29 15.06 652 285 0.28 / 795.09 2 3
2 7 2004.48 30 15.06 2966 1340 1.62 / 796.43 2 2
3 13 1610.36 29 15.00 2504 1089 2.71 / 797.52 2 3
4 13 681.72 29 15.08 1324 579 3.29 / 798.09 2 4
5 13 20.68 29 15.19 457 201 3.49 / 798.30 2 6
6 8 0.48 175 15.14 401 1062 4.56 / 799.36 2 13
Average= 4.44
(KJ/cycle)

Cycle 178 GMT 6/10/2023 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.00 29 15.08 650 284 0.28 / 790.55 2 3
2 7 2002.64 30 15.07 2960 1338 1.62 / 791.89 2 2
3 13 1598.44 29 15.01 2472 1076 2.70 / 792.96 2 3
4 13 683.36 29 15.08 1322 578 3.28 / 793.54 2 5
5 13 41.96 29 15.19 481 212 3.49 / 793.75 2 5
6 8 -0.36 175 15.14 396 1049 4.54 / 794.80 2 12
Average= 4.44
(KJ/cycle)

Cycle 177 GMT 26/ 9/2023 23:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.80 29 15.07 655 286 0.29 / 786.08 2 2
2 7 2006.56 30 15.07 2968 1342 1.63 / 787.42 2 2
3 13 1736.88 29 15.00 2626 1142 2.77 / 788.56 2 3
4 13 762.64 29 15.07 1427 624 3.39 / 789.18 2 4
5 8 0.52 175 15.16 407 1080 4.47 / 790.26 2 15
Average= 4.44
(KJ/cycle)

Cycle 176 GMT 17/ 9/2023 2: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.08 29 15.07 649 284 0.28 / 781.63 2 3
2 7 2003.20 30 15.06 2955 1335 1.62 / 782.97 2 2
3 13 1578.88 29 15.01 2461 1071 2.69 / 784.04 2 3
4 13 656.88 29 15.09 1287 563 3.25 / 784.60 2 4
5 8 -0.48 175 15.16 402 1067 4.32 / 785.67 2 12
6 14 -0.48 20 15.13 406 123 4.44 / 785.79 2 12
Average= 4.44
(KJ/cycle)

Cycle 175 GMT 7/ 9/2023 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.96 29 15.07 655 286 0.29 / 777.08 2 3
2 7 2003.44 30 15.07 2961 1339 1.62 / 778.42 2 2
3 13 1602.00 29 15.01 2475 1077 2.70 / 779.50 2 3
4 13 682.24 29 15.09 1322 579 3.28 / 780.08 2 5
5 13 39.52 29 15.20 475 209 3.49 / 780.29 2 5
6 8 0.36 175 15.15 400 1060 4.55 / 781.35 2 12
Average= 4.44
(KJ/cycle)

Cycle 174 GMT 28/ 8/2023 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.36 29 15.07 633 277 0.28 / 772.54 2 3
2 7 2002.64 30 15.07 2953 1335 1.61 / 773.88 2 2
3 13 1598.04 29 15.02 2476 1078 2.69 / 774.96 2 3
4 13 666.84 29 15.09 1310 573 3.26 / 775.53 2 5
5 13 19.28 29 15.20 456 201 3.46 / 775.73 2 5
6 8 0.00 175 15.15 402 1066 4.53 / 776.80 2 13
Average= 4.44
(KJ/cycle)

Cycle 173 GMT 18/ 8/2023 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.64 29 15.07 652 285 0.28 / 767.88 2 3
2 7 2008.04 30 15.08 2964 1341 1.63 / 769.22 2 3
3 13 1741.08 29 15.00 2649 1152 2.78 / 770.38 2 3
4 13 689.80 29 15.08 1336 584 3.36 / 770.96 2 5
5 13 91.88 29 15.18 550 242 3.60 / 771.20 2 6
6 8 0.20 175 15.15 401 1063 4.67 / 772.27 2 15
Average= 4.44
(KJ/cycle)

Cycle 172 GMT 8/ 8/2023 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.64 29 15.06 639 279 0.28 / 763.28 2 3
2 7 2007.60 30 15.07 2975 1345 1.62 / 764.63 2 3
3 13 1591.08 29 15.03 2457 1071 2.70 / 765.70 2 3
4 13 670.40 29 15.09 1322 579 3.27 / 766.27 2 4
5 13 76.36 29 15.19 538 237 3.51 / 766.51 2 5
6 8 0.24 175 15.15 410 1087 4.60 / 767.60 2 15
Average= 4.44
(KJ/cycle)

Cycle 171 GMT 29/ 7/2023 12:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.92 29 15.06 637 278 0.28 / 758.50 2 3
2 7 2006.24 30 15.07 2976 1345 1.62 / 759.85 2 3
3 13 1579.00 29 15.03 2456 1070 2.69 / 760.92 2 3
4 13 788.88 29 15.07 1474 644 3.34 / 761.56 2 6
5 13 55.92 29 15.19 519 229 3.57 / 761.79 2 5
6 8 0.16 175 15.15 410 1087 4.65 / 762.88 2 17
7 14 0.16 20 15.13 405 123 4.78 / 763.00 2 16
Average= 4.44
(KJ/cycle)

Cycle 170 GMT 19/ 7/2023 15: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.52 30 15.08 652 295 0.29 / 753.84 2 3
2 7 2003.48 30 15.08 2971 1344 1.64 / 755.19 2 3
3 13 1609.56 29 15.01 2495 1086 2.73 / 756.27 2 4
4 13 811.24 29 15.06 1502 656 3.38 / 756.93 2 4
5 13 61.68 29 15.19 512 226 3.61 / 757.15 2 5
6 8 -0.04 175 15.15 404 1071 4.68 / 758.22 2 15
Average= 4.43
(KJ/cycle)

Cycle 169 GMT 9/ 7/2023 17:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.20 30 15.08 662 299 0.30 / 749.43 2 3
2 3 972.88 -1 15.50 7 0 0.00 / 749.43 2 3
3 7 2002.56 31 15.06 2967 1385 1.68 / 750.82 2 3
4 13 1601.88 29 15.02 2478 1079 2.76 / 751.90 2 3
5 13 666.12 29 15.09 1302 570 3.33 / 752.47 2 4
6 8 0.12 175 15.17 407 1080 4.41 / 753.55 2 9
Average= 4.43
(KJ/cycle)

Cycle 168 GMT 29/ 6/2023 19:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.56 30 15.08 629 285 0.28 / 745.04 2 2
2 7 2004.20 30 15.07 2955 1336 1.62 / 746.37 2 3
3 13 1600.44 29 15.02 2473 1077 2.70 / 747.45 2 3
4 13 678.40 29 15.09 1322 579 3.28 / 748.03 2 4
5 8 0.32 175 15.17 416 1104 4.38 / 749.13 2 19
Average= 4.43
(KJ/cycle)

Cycle 167 GMT 19/ 6/2023 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.20 30 15.08 627 284 0.28 / 740.39 2 3
2 3 976.40 -1 15.50 7 0 0.00 / 740.39 2 3
3 7 2003.76 30 15.08 2961 1340 1.62 / 741.73 2 2
4 13 1599.36 29 15.03 2473 1078 2.70 / 742.81 2 4
5 13 818.32 29 15.07 1502 656 3.36 / 743.46 2 6
6 13 62.72 29 15.20 504 222 3.58 / 743.69 2 5
7 8 0.52 175 15.16 402 1067 4.65 / 744.75 2 10
Average= 4.43
(KJ/cycle)

Cycle 166 GMT 10/ 6/2023 0: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.00 31 15.10 645 302 0.30 / 735.66 2 3
2 3 972.72 -1 15.50 7 0 0.00 / 735.66 2 3
3 7 2003.56 30 15.08 2968 1343 1.64 / 737.00 2 2
4 13 1599.12 29 15.02 2471 1076 2.72 / 738.08 2 3
5 13 812.72 29 15.07 1486 649 3.37 / 738.73 2 5
6 13 14.04 29 15.21 438 193 3.56 / 738.92 2 5
7 8 -0.16 175 15.16 401 1064 4.63 / 739.99 2 12
8 14 -0.16 20 15.13 399 121 4.75 / 740.11 2 14
Average= 4.43
(KJ/cycle)

Cycle 165 GMT 31/ 5/2023 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.88 31 15.10 648 303 0.30 / 731.22 2 2
2 7 2003.12 30 15.08 2957 1338 1.64 / 732.55 2 3
3 13 1603.64 29 15.02 2485 1082 2.72 / 733.64 2 4
4 13 815.00 29 15.07 1490 651 3.37 / 734.29 2 4
5 8 0.12 175 15.18 403 1071 4.45 / 735.36 2 14
Average= 4.43
(KJ/cycle)

Cycle 164 GMT 21/ 5/2023 4:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.52 33 15.09 632 315 0.31 / 726.71 2 2
2 3 945.36 -2 15.50 8 0 0.00 / 726.71 2 2
3 3 986.08 -1 15.54 8 0 0.00 / 726.71 2 2
4 7 2002.64 31 15.08 2955 1381 1.70 / 728.09 2 2
5 13 1725.52 29 15.02 2599 1132 2.83 / 729.23 2 3
6 13 773.04 29 15.08 1426 624 3.45 / 729.85 2 4
7 8 0.04 175 15.18 400 1063 4.51 / 730.91 2 8
Average= 4.43
(KJ/cycle)

Cycle 163 GMT 11/ 5/2023 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.20 33 15.10 603 300 0.30 / 721.99 2 2
2 3 974.36 -1 15.51 7 0 0.00 / 721.99 2 2
3 7 2006.80 31 15.08 2959 1383 1.68 / 723.37 2 2
4 13 1729.88 29 15.01 2629 1144 2.83 / 724.51 2 2
5 13 783.40 29 15.08 1450 634 3.46 / 725.15 2 4
6 13 30.48 29 15.22 451 199 3.66 / 725.35 2 5
7 8 0.24 175 15.17 396 1051 4.71 / 726.40 2 14
Average= 4.43
(KJ/cycle)

Cycle 162 GMT 1/ 5/2023 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.24 33 15.11 624 311 0.31 / 717.30 2 2
2 3 1027.68 1 15.25 1843 28 0.34 / 717.33 2 3
3 7 2008.88 30 15.09 2945 1333 1.67 / 718.66 2 2
4 13 1610.32 29 15.03 2469 1076 2.75 / 719.74 2 3
5 13 958.80 29 15.05 1664 726 3.47 / 720.47 2 4
6 13 29.56 29 15.22 441 195 3.67 / 720.66 2 5
7 8 0.12 175 15.17 386 1025 4.69 / 721.69 2 13
Average= 4.43
(KJ/cycle)

Cycle 161 GMT 21/ 4/2023 11: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.60 32 15.09 612 296 0.30 / 712.61 2 2
2 3 1021.80 1 15.25 1813 28 0.32 / 712.64 2 3
3 7 2007.36 30 15.09 2943 1332 1.66 / 713.97 2 2
4 13 1752.08 29 15.02 2645 1152 2.81 / 715.13 2 3
5 13 823.64 29 15.07 1482 648 3.46 / 715.77 2 4
6 13 40.16 29 15.22 451 199 3.65 / 715.97 2 4
7 8 -0.08 175 15.17 384 1019 4.67 / 716.99 2 13
Average= 4.43
(KJ/cycle)

Cycle 160 GMT 11/ 4/2023 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.40 32 15.10 614 297 0.30 / 707.90 2 2
2 7 2011.16 30 15.09 2956 1338 1.63 / 709.24 2 2
3 13 1486.12 29 15.05 2322 1013 2.65 / 710.25 2 3
4 13 861.12 29 15.06 1534 670 3.32 / 710.92 2 5
5 13 106.28 29 15.20 547 241 3.56 / 711.16 2 4
6 8 0.20 175 15.17 391 1038 4.60 / 712.20 2 14
7 14 0.20 20 15.14 384 116 4.71 / 712.32 2 18
Average= 4.42
(KJ/cycle)

Cycle 159 GMT 1/ 4/2023 15:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.08 33 15.09 635 316 0.32 / 703.20 2 2
2 7 2008.76 30 15.10 2955 1339 1.65 / 704.54 2 3
3 13 1737.96 29 15.02 2627 1144 2.80 / 705.68 2 3
4 13 819.28 29 15.07 1490 651 3.45 / 706.33 2 4
5 13 79.20 29 15.21 516 228 3.68 / 706.56 2 4
6 8 0.08 175 15.17 393 1043 4.72 / 707.60 2 10
Average= 4.42
(KJ/cycle)

Cycle 158 GMT 22/ 3/2023 17:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.72 32 15.10 627 303 0.30 / 698.62 2 2
2 7 2006.96 30 15.09 2960 1340 1.64 / 699.96 2 2
3 13 1490.00 29 15.05 2338 1020 2.66 / 700.98 2 3
4 13 866.88 29 15.07 1553 679 3.34 / 701.66 2 5
5 13 17.92 29 15.22 432 191 3.53 / 701.85 2 4
6 8 0.08 175 15.17 388 1030 4.56 / 702.88 2 16
Average= 4.42
(KJ/cycle)

Cycle 157 GMT 12/ 3/2023 20:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.84 32 15.10 635 307 0.31 / 693.69 2 2
2 7 2006.92 31 15.09 2955 1382 1.69 / 695.07 2 2
3 13 1744.80 29 15.02 2654 1156 2.85 / 696.23 2 4
4 13 950.08 29 15.05 1653 721 3.57 / 696.95 2 5
5 13 27.96 29 15.22 450 199 3.77 / 697.15 2 4
6 8 0.20 175 15.17 396 1051 4.82 / 698.20 2 13
7 14 0.20 20 15.15 401 122 4.94 / 698.32 2 13
Average= 4.42
(KJ/cycle)

Cycle 156 GMT 2/ 3/2023 22:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.56 33 15.11 607 303 0.30 / 689.04 2 2
2 3 983.36 -1 15.55 9 0 0.00 / 689.04 2 2
3 7 2010.84 30 15.09 2960 1340 1.64 / 690.38 2 2
4 13 1629.84 29 15.04 2503 1092 2.73 / 691.47 2 2
5 13 873.32 29 15.07 1548 677 3.41 / 692.15 2 5
6 13 42.56 29 15.22 467 206 3.62 / 692.36 2 4
7 8 0.08 175 15.18 386 1025 4.64 / 693.38 2 10
Average= 4.42
(KJ/cycle)

Cycle 155 GMT 21/ 2/2023 1:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 170.60 33 15.10 630 314 0.31 / 684.34 2 2
2 7 2009.84 31 15.09 2960 1385 1.70 / 685.72 2 2
3 13 1602.08 29 15.04 2471 1078 2.78 / 686.80 2 3
4 13 968.04 29 15.05 1686 736 3.51 / 687.54 2 6
5 13 26.88 29 15.22 449 198 3.71 / 687.74 2 4
6 8 -0.12 175 15.18 378 1004 4.71 / 688.74 2 9
Average= 4.41
(KJ/cycle)

Cycle 154 GMT 11/ 2/2023 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.28 33 15.12 627 313 0.31 / 679.56 2 3
2 7 2006.68 31 15.09 2960 1385 1.70 / 680.94 2 2
3 13 1605.16 29 15.03 2476 1079 2.78 / 682.02 2 4
4 13 843.72 29 15.08 1513 662 3.44 / 682.68 2 4
5 13 67.20 29 15.21 496 219 3.66 / 682.90 2 4
6 8 -0.08 175 15.18 379 1007 4.66 / 683.91 2 15
7 14 -0.08 20 15.16 381 116 4.78 / 684.03 2 14
Average= 4.41
(KJ/cycle)

Cycle 153 GMT 1/ 2/2023 6: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.56 33 15.11 628 313 0.31 / 674.77 2 2
2 7 2011.64 30 15.10 2966 1344 1.66 / 676.12 2 2
3 13 1752.60 29 15.02 2647 1153 2.81 / 677.27 2 4
4 13 848.48 29 15.08 1527 668 3.48 / 677.94 2 4
5 13 36.36 29 15.23 446 197 3.67 / 678.13 2 4
6 8 0.16 175 15.19 375 997 4.67 / 679.13 2 16
7 14 0.16 20 15.16 377 114 4.79 / 679.25 2 10
Average= 4.41
(KJ/cycle)

Cycle 152 GMT 22/ 1/2023 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.60 33 15.13 612 306 0.31 / 670.02 2 2
2 7 2008.76 30 15.09 2946 1334 1.64 / 671.36 2 3
3 13 1741.88 29 15.02 2634 1147 2.79 / 672.51 2 4
4 13 808.08 29 15.09 1471 644 3.43 / 673.15 2 4
5 13 35.08 29 15.23 443 196 3.63 / 673.35 2 4
6 8 0.12 175 15.19 376 1000 4.63 / 674.34 2 10
7 14 0.12 20 15.16 380 115 4.74 / 674.46 2 12
Average= 4.41
(KJ/cycle)

Cycle 151 GMT 12/ 1/2023 10:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.24 33 15.12 623 311 0.31 / 665.61 2 2
2 7 2003.28 30 15.10 2946 1335 1.65 / 666.94 2 2
3 13 1725.32 29 15.03 2622 1143 2.79 / 668.08 2 3
4 13 789.04 29 15.09 1437 629 3.42 / 668.71 2 4
5 8 0.24 175 15.20 378 1005 4.42 / 669.72 2 15
Average= 4.41
(KJ/cycle)

Cycle 150 GMT 2/ 1/2023 13: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.56 33 15.13 617 308 0.31 / 661.06 2 2
2 7 2006.92 31 15.09 2954 1382 1.69 / 662.44 2 2
3 13 1606.28 29 15.04 2467 1076 2.77 / 663.52 2 3
4 13 834.40 29 15.08 1496 654 3.42 / 664.17 2 5
5 8 -0.16 175 15.19 379 1007 4.43 / 665.18 2 9
6 14 -0.16 20 15.17 381 116 4.54 / 665.30 2 14
Average= 4.41
(KJ/cycle)

Cycle 149 GMT 23/12/2022 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.12 33 15.11 615 307 0.31 / 656.70 2 2
2 7 2003.84 30 15.10 2937 1330 1.64 / 658.03 2 2
3 13 1599.04 29 15.04 2456 1071 2.71 / 659.10 2 3
4 13 837.60 29 15.08 1505 658 3.37 / 659.76 2 5
5 8 0.28 175 15.20 375 997 4.36 / 660.75 2 10
Average= 4.41
(KJ/cycle)

Cycle 148 GMT 13/12/2022 17:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.68 33 15.11 629 314 0.31 / 652.13 2 2
2 7 2007.40 30 15.10 2954 1338 1.65 / 653.47 2 3
3 13 1604.08 29 15.05 2458 1073 2.72 / 654.54 2 3
4 13 841.52 29 15.08 1512 661 3.39 / 655.20 2 4
5 13 21.16 29 15.24 423 187 3.57 / 655.39 2 4
6 8 0.08 175 15.19 377 1002 4.57 / 656.39 2 13
Average= 4.41
(KJ/cycle)

Cycle 147 GMT 3/12/2022 19:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.00 33 15.12 615 307 0.31 / 647.39 2 2
2 7 2010.32 31 15.10 2952 1382 1.69 / 648.77 2 2
3 13 1610.28 29 15.04 2468 1076 2.77 / 649.85 2 3
4 13 837.64 29 15.09 1493 653 3.42 / 650.50 2 5
5 13 35.40 29 15.23 442 195 3.61 / 650.70 2 4
6 8 0.08 175 15.19 376 1000 4.61 / 651.70 2 9
7 14 0.08 20 15.16 380 115 4.73 / 651.81 2 14
Average= 4.40
(KJ/cycle)

Cycle 146 GMT 23/11/2022 22: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.96 33 15.11 614 306 0.31 / 642.70 2 2
2 7 2006.76 30 15.11 2938 1332 1.64 / 644.03 2 2
3 13 1614.00 29 15.05 2456 1072 2.71 / 645.11 2 4
4 13 855.88 29 15.09 1516 663 3.37 / 645.77 2 6
5 13 43.92 29 15.23 455 201 3.57 / 645.97 2 4
6 8 0.12 175 15.19 377 1002 4.58 / 646.97 2 11
7 14 0.12 20 15.17 374 113 4.69 / 647.09 2 14
Average= 4.40
(KJ/cycle)

Cycle 145 GMT 14/11/2022 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.96 33 15.13 623 311 0.31 / 638.10 2 2
2 7 2009.56 30 15.10 2938 1331 1.64 / 639.43 2 2
3 13 1732.20 29 15.03 2610 1138 2.78 / 640.57 2 3
4 13 816.04 29 15.09 1460 639 3.42 / 641.20 2 4
5 13 36.08 29 15.23 441 195 3.61 / 641.40 2 4
6 8 -0.20 175 15.19 375 997 4.61 / 642.40 2 10
Average= 4.40
(KJ/cycle)

Cycle 144 GMT 4/11/2022 2:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.96 33 15.11 608 303 0.30 / 633.55 2 2
2 3 1021.32 1 15.26 1817 28 0.33 / 633.58 2 2
3 7 2008.56 31 15.11 2948 1381 1.71 / 634.96 2 2
4 13 1612.88 29 15.05 2478 1082 2.79 / 636.04 2 3
5 13 838.68 29 15.09 1493 653 3.45 / 636.69 2 6
6 8 0.20 175 15.21 368 980 4.43 / 637.67 2 10
7 14 0.20 20 15.18 378 115 4.54 / 637.79 2 13
Average= 4.40
(KJ/cycle)

Cycle 143 GMT 25/10/2022 4:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.44 32 15.13 612 296 0.30 / 628.86 2 2
2 3 1045.92 1 15.24 1854 28 0.32 / 628.88 2 2
3 7 2003.44 31 15.11 2939 1377 1.70 / 630.26 2 2
4 13 1611.88 29 15.05 2484 1084 2.79 / 631.34 2 3
5 13 846.76 29 15.09 1503 658 3.44 / 632.00 2 4
6 13 101.68 29 15.22 539 238 3.68 / 632.24 2 4
7 8 0.04 175 15.19 378 1005 4.69 / 633.25 2 12
Average= 4.40
(KJ/cycle)

Cycle 142 GMT 15/10/2022 7:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.24 31 15.13 595 279 0.28 / 624.24 2 2
2 3 1021.48 1 15.26 1811 28 0.31 / 624.27 2 2
3 7 2002.28 30 15.11 2942 1334 1.64 / 625.61 2 2
4 13 1726.76 29 15.04 2618 1142 2.78 / 626.75 2 2
5 13 920.96 29 15.09 1609 704 3.49 / 627.45 2 6
6 8 0.32 175 15.22 373 993 4.48 / 628.45 2 13
7 14 0.32 20 15.19 376 114 4.59 / 628.56 2 13
Average= 4.40
(KJ/cycle)

Cycle 141 GMT 5/10/2022 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.96 31 15.13 616 289 0.29 / 619.84 2 2
2 7 2010.48 30 15.10 2954 1338 1.63 / 621.18 2 2
3 13 1737.44 29 15.03 2629 1146 2.77 / 622.33 2 2
4 13 788.96 29 15.10 1435 628 3.40 / 622.96 2 4
5 8 0.28 175 15.21 379 1009 4.41 / 623.97 2 11
Average= 4.39
(KJ/cycle)

Cycle 140 GMT 25/ 9/2022 12:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.52 31 15.12 606 284 0.28 / 615.52 2 2
2 7 2009.60 30 15.10 2955 1339 1.62 / 616.86 2 2
3 13 1594.92 29 15.05 2438 1064 2.69 / 617.93 2 3
4 13 804.76 29 15.10 1456 638 3.32 / 618.56 2 5
5 8 -0.16 175 15.22 372 991 4.32 / 619.56 2 12
Average= 4.39
(KJ/cycle)

Cycle 139 GMT 15/ 9/2022 14:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.12 31 15.13 617 289 0.29 / 610.96 2 2
2 3 1017.16 1 15.27 1813 28 0.32 / 610.99 2 2
3 7 2007.28 30 15.11 2958 1341 1.66 / 612.33 2 2
4 13 1611.76 29 15.05 2472 1079 2.74 / 613.41 2 3
5 13 828.08 29 15.10 1492 653 3.39 / 614.06 2 4
6 13 16.08 29 15.25 418 185 3.58 / 614.25 2 5
7 8 0.24 175 15.20 373 992 4.57 / 615.24 2 16
Average= 4.39
(KJ/cycle)

Cycle 138 GMT 5/ 9/2022 16:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.68 31 15.12 634 297 0.30 / 606.48 2 2
2 7 2005.20 30 15.10 2950 1336 1.63 / 607.82 2 3
3 13 1591.44 29 15.05 2447 1068 2.70 / 608.89 2 3
4 13 804.80 29 15.10 1463 641 3.34 / 609.53 2 5
5 8 0.04 175 15.21 386 1027 4.37 / 610.55 2 11
6 14 0.04 20 15.19 390 118 4.49 / 610.67 2 15
Average= 4.39
(KJ/cycle)

Cycle 137 GMT 26/ 8/2022 19:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.72 31 15.13 621 291 0.29 / 601.88 2 2
2 7 2010.08 30 15.11 2950 1337 1.63 / 603.22 2 2
3 13 1621.44 29 15.05 2473 1079 2.71 / 604.30 2 3
4 13 824.52 29 15.10 1479 648 3.36 / 604.95 2 5
5 13 74.52 29 15.23 497 220 3.58 / 605.17 2 5
6 8 0.16 175 15.20 382 1016 4.59 / 606.18 2 13
Average= 4.39
(KJ/cycle)

Cycle 136 GMT 16/ 8/2022 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.32 31 15.14 616 289 0.29 / 597.37 2 2
2 7 2002.28 31 15.10 2941 1377 1.67 / 598.74 2 3
3 13 1603.36 29 15.05 2464 1075 2.74 / 599.82 2 4
4 13 814.00 29 15.10 1468 643 3.38 / 600.46 2 4
5 8 0.00 175 15.22 381 1015 4.40 / 601.48 2 12
6 14 0.00 20 15.19 382 116 4.51 / 601.59 2 13
Average= 4.39
(KJ/cycle)

Cycle 135 GMT 6/ 8/2022 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.24 31 15.12 623 292 0.29 / 593.08 2 2
2 7 2011.32 30 15.12 2952 1339 1.63 / 594.42 2 2
3 13 1600.48 29 15.06 2463 1076 2.71 / 595.49 2 3
4 13 713.64 29 15.12 1338 587 3.29 / 596.08 2 5
5 8 1.28 175 15.22 375 999 4.29 / 597.08 2 11
Average= 4.39
(KJ/cycle)

Cycle 134 GMT 28/ 7/2022 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.76 30 15.13 614 279 0.28 / 588.44 2 2
2 3 1024.60 1 15.25 1836 28 0.31 / 588.46 2 2
3 7 2005.08 30 15.12 2939 1333 1.64 / 589.80 2 2
4 13 1735.60 29 15.04 2636 1150 2.79 / 590.95 2 4
5 13 785.84 29 15.11 1442 632 3.42 / 591.58 2 4
6 13 29.72 29 15.25 444 196 3.62 / 591.78 2 6
7 8 0.08 175 15.21 380 1011 4.63 / 592.79 2 12
Average= 4.39
(KJ/cycle)

Cycle 133 GMT 18/ 7/2022 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.12 30 15.12 624 283 0.28 / 583.89 2 2
2 7 2005.60 30 15.11 2940 1333 1.62 / 585.23 2 3
3 13 1591.24 29 15.06 2449 1070 2.69 / 586.30 2 3
4 13 795.40 29 15.11 1445 633 3.32 / 586.93 2 4
5 13 62.88 29 15.24 486 215 3.53 / 587.14 2 5
6 8 -0.36 175 15.20 381 1013 4.55 / 588.16 2 14
Average= 4.39
(KJ/cycle)

Cycle 132 GMT 8/ 7/2022 6:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.92 30 15.14 622 283 0.28 / 579.37 2 3
2 7 2006.64 30 15.10 2954 1338 1.62 / 580.71 2 3
3 13 1594.32 29 15.05 2449 1069 2.69 / 581.77 2 3
4 13 805.12 29 15.10 1465 642 3.33 / 582.42 2 4
5 13 32.48 29 15.25 443 196 3.53 / 582.61 2 5
6 8 0.32 175 15.21 375 998 4.53 / 583.61 2 15
Average= 4.39
(KJ/cycle)

Cycle 131 GMT 28/ 6/2022 8:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.52 30 15.12 622 282 0.28 / 575.02 2 2
2 7 2003.84 30 15.12 2944 1335 1.62 / 576.35 2 2
3 13 1596.44 29 15.06 2450 1070 2.69 / 577.42 2 4
4 13 816.32 29 15.11 1464 642 3.33 / 578.06 2 4
5 8 -0.36 175 15.22 384 1023 4.35 / 579.09 2 10
Average= 4.39
(KJ/cycle)

Cycle 130 GMT 18/ 6/2022 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.88 30 15.12 623 283 0.28 / 570.45 2 2
2 7 2002.64 30 15.11 2947 1336 1.62 / 571.79 2 2
3 13 1593.84 29 15.06 2453 1071 2.69 / 572.86 2 5
4 13 808.96 29 15.11 1460 640 3.33 / 573.50 2 5
5 13 61.44 29 15.24 484 214 3.54 / 573.71 2 5
6 8 0.40 175 15.20 384 1021 4.56 / 574.73 2 14
Average= 4.39
(KJ/cycle)

Cycle 129 GMT 8/ 6/2022 13: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.44 30 15.15 603 274 0.27 / 565.77 2 2
2 7 2004.24 30 15.10 2955 1339 1.61 / 567.11 2 3
3 13 1598.80 29 15.05 2463 1075 2.69 / 568.18 2 3
4 13 790.64 29 15.11 1456 638 3.33 / 568.82 2 5
5 13 55.76 29 15.24 486 215 3.54 / 569.04 2 5
6 8 -0.24 175 15.20 381 1013 4.55 / 570.05 2 10
7 14 -0.24 20 15.18 395 120 4.67 / 570.17 2 15
Average= 4.39
(KJ/cycle)

Cycle 128 GMT 29/ 5/2022 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.60 30 15.13 616 280 0.28 / 561.45 2 3
2 7 2003.44 30 15.11 2938 1332 1.61 / 562.78 2 3
3 13 1599.16 29 15.05 2469 1078 2.69 / 563.85 2 4
4 13 797.76 29 15.11 1445 633 3.32 / 564.49 2 5
5 8 0.64 175 15.22 378 1007 4.33 / 565.49 2 10
Average= 4.38
(KJ/cycle)

Cycle 127 GMT 19/ 5/2022 17:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.80 30 15.15 604 275 0.27 / 556.77 2 2
2 7 2007.92 30 15.12 2958 1342 1.62 / 558.11 2 2
3 13 1730.56 29 15.04 2613 1140 2.76 / 559.25 2 3
4 13 891.96 29 15.10 1561 684 3.44 / 559.94 2 3
5 13 95.36 29 15.24 532 235 3.67 / 560.17 2 4
6 8 0.16 175 15.21 374 995 4.67 / 561.17 2 16
Average= 4.38
(KJ/cycle)

Cycle 126 GMT 9/ 5/2022 19:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.20 30 15.14 630 286 0.29 / 552.43 2 2
2 7 2005.00 30 15.11 2955 1340 1.63 / 553.77 2 2
3 13 1601.72 29 15.06 2470 1079 2.70 / 554.85 2 3
4 13 804.56 29 15.11 1469 644 3.35 / 555.50 2 4
5 8 -0.16 175 15.23 375 999 4.35 / 556.50 2 17
Average= 4.38
(KJ/cycle)

Cycle 125 GMT 29/ 4/2022 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.80 30 15.15 614 279 0.28 / 547.78 2 2
2 7 2002.80 30 15.11 2950 1337 1.62 / 549.12 2 2
3 13 1591.60 29 15.06 2450 1070 2.69 / 550.19 2 3
4 13 798.16 29 15.12 1456 638 3.32 / 550.82 2 4
5 13 58.76 29 15.25 477 211 3.54 / 551.03 2 5
6 8 0.16 175 15.21 375 998 4.53 / 552.03 2 16
7 14 0.16 20 15.19 379 115 4.65 / 552.15 2 14
Average= 4.38
(KJ/cycle)

Cycle 124 GMT 20/ 4/2022 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.64 30 15.14 617 280 0.28 / 543.43 2 2
2 7 2003.88 30 15.12 2944 1335 1.62 / 544.77 2 2
3 13 1604.80 29 15.06 2473 1080 2.70 / 545.85 2 3
4 13 820.84 29 15.11 1493 654 3.35 / 546.50 2 4
5 8 -0.08 175 15.23 374 997 4.35 / 547.50 2 13
Average= 4.38
(KJ/cycle)

Cycle 123 GMT 10/ 4/2022 2: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.68 30 15.16 600 273 0.27 / 538.88 2 2
2 7 2005.60 30 15.12 2952 1339 1.61 / 540.22 2 2
3 13 1612.60 29 15.06 2487 1086 2.70 / 541.31 2 3
4 13 837.12 29 15.11 1492 654 3.35 / 541.96 2 4
5 13 23.88 29 15.26 434 192 3.54 / 542.15 2 4
6 8 0.44 175 15.22 376 1001 4.55 / 543.15 2 13
Average= 4.38
(KJ/cycle)

Cycle 122 GMT 31/ 3/2022 4:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.00 30 15.15 593 270 0.27 / 534.39 2 2
2 7 2001.96 31 15.11 2947 1380 1.65 / 535.77 2 3
3 13 1592.24 29 15.07 2443 1068 2.72 / 536.84 2 3
4 13 817.16 29 15.11 1486 651 3.37 / 537.49 2 5
5 8 0.08 175 15.23 376 1002 4.37 / 538.49 2 11
6 14 0.08 20 15.21 383 117 4.49 / 538.61 2 10
Average= 4.38
(KJ/cycle)

Cycle 121 GMT 21/ 3/2022 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.56 30 15.15 611 278 0.28 / 529.91 2 2
2 7 2004.92 30 15.11 2940 1333 1.61 / 531.24 2 3
3 13 1589.96 29 15.07 2450 1071 2.68 / 532.31 2 3
4 13 800.60 29 15.12 1451 636 3.32 / 532.95 2 4
5 13 25.32 29 15.27 426 189 3.51 / 533.13 2 5
6 8 -0.04 175 15.22 370 985 4.49 / 534.12 2 13
Average= 4.38
(KJ/cycle)

Cycle 120 GMT 11/ 3/2022 8:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.40 30 15.15 623 283 0.28 / 525.56 2 2
2 7 2006.80 30 15.11 2944 1335 1.62 / 526.89 2 2
3 13 1483.64 29 15.07 2317 1013 2.63 / 527.90 2 6
4 13 725.56 29 15.12 1374 602 3.23 / 528.51 2 5
5 8 0.32 175 15.23 377 1005 4.24 / 529.51 2 12
6 14 0.32 20 15.20 385 117 4.35 / 529.63 3 17
Average= 4.38
(KJ/cycle)

Cycle 119 GMT 1/ 3/2022 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.80 31 15.16 612 288 0.29 / 521.24 2 2
2 7 2003.84 30 15.11 2944 1335 1.62 / 522.57 2 2
3 13 1589.84 29 15.07 2442 1067 2.69 / 523.64 2 3
4 13 791.72 29 15.12 1459 640 3.33 / 524.28 2 4
5 8 0.08 175 15.24 373 995 4.32 / 525.27 2 11
Average= 4.38
(KJ/cycle)

Cycle 118 GMT 19/ 2/2022 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.56 31 15.16 619 291 0.29 / 516.93 2 2
2 7 2007.72 30 15.12 2947 1337 1.63 / 518.27 2 3
3 13 1601.12 29 15.06 2456 1073 2.70 / 519.34 2 3
4 13 799.04 29 15.12 1457 639 3.34 / 519.98 2 4
5 8 0.20 175 15.24 363 968 4.31 / 520.95 2 11
Average= 4.38
(KJ/cycle)

Cycle 117 GMT 9/ 2/2022 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.80 31 15.16 604 284 0.28 / 512.53 2 2
2 7 2003.48 30 15.12 2949 1338 1.62 / 513.86 2 2
3 13 1596.20 29 15.07 2451 1071 2.69 / 514.93 2 3
4 13 806.84 29 15.12 1456 638 3.33 / 515.57 2 3
5 13 50.56 5 15.28 483 37 3.37 / 515.61 2 4
6 13 41.00 5 15.28 471 36 3.40 / 515.65 2 4
7 8 0.04 175 15.23 374 997 4.40 / 516.64 2 11
Average= 4.38
(KJ/cycle)

Cycle 116 GMT 30/ 1/2022 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.32 31 15.16 626 294 0.29 / 508.16 2 2
2 7 2003.36 30 15.13 2946 1337 1.63 / 509.50 2 3
3 13 1610.00 29 15.07 2483 1085 2.72 / 510.58 2 4
4 13 806.68 29 15.12 1471 645 3.36 / 511.23 2 5
5 8 0.04 175 15.24 381 1016 4.38 / 512.24 2 12
Average= 4.38
(KJ/cycle)

Cycle 115 GMT 20/ 1/2022 19:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.96 31 15.16 618 290 0.29 / 503.69 2 2
2 7 2004.04 30 15.12 2940 1334 1.62 / 505.03 2 3
3 13 1606.12 29 15.06 2470 1079 2.70 / 506.11 2 2
4 13 813.00 29 15.12 1471 645 3.35 / 506.75 2 4
5 8 0.04 175 15.24 374 997 4.35 / 507.75 2 11
6 14 0.04 20 15.22 378 115 4.46 / 507.86 2 10
Average= 4.38
(KJ/cycle)

Cycle 114 GMT 10/ 1/2022 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.88 31 15.16 614 289 0.29 / 499.33 2 2
2 7 2004.24 30 15.12 2939 1333 1.62 / 500.67 2 3
3 13 1599.56 29 15.07 2450 1071 2.69 / 501.74 2 3
4 13 812.76 29 15.13 1467 644 3.34 / 502.38 2 4
5 13 69.80 6 15.27 507 46 3.38 / 502.43 2 4
6 8 0.04 175 15.24 366 976 4.36 / 503.40 2 11
Average= 4.38
(KJ/cycle)

Cycle 113 GMT 1/ 1/2022 0:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.12 30 15.16 618 281 0.28 / 494.99 2 2
2 7 2002.68 30 15.12 2940 1334 1.61 / 496.32 2 3
3 13 1582.08 29 15.07 2446 1069 2.68 / 497.39 2 4
4 13 799.44 29 15.13 1455 638 3.32 / 498.03 2 5
5 8 0.20 175 15.24 382 1019 4.34 / 499.05 2 11
Average= 4.38
(KJ/cycle)

Cycle 112 GMT 22/12/2021 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.40 31 15.16 619 291 0.29 / 490.57 2 2
2 7 2005.80 30 15.13 2955 1341 1.63 / 491.91 2 3
3 13 1595.08 29 15.07 2466 1078 2.71 / 492.99 2 4
4 13 805.80 29 15.13 1474 647 3.36 / 493.64 2 4
5 13 71.36 6 15.28 515 47 3.40 / 493.68 2 4
6 8 0.00 175 15.24 383 1021 4.43 / 494.70 2 12
Average= 4.38
(KJ/cycle)

Cycle 111 GMT 12/12/2021 4:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.28 31 15.17 611 287 0.29 / 486.23 2 2
2 7 2003.24 30 15.13 2950 1339 1.63 / 487.57 2 2
3 13 1593.36 29 15.08 2440 1067 2.69 / 488.64 2 3
4 13 824.76 29 15.13 1477 648 3.34 / 489.29 2 5
5 8 0.28 175 15.25 372 993 4.33 / 490.28 2 12
Average= 4.38
(KJ/cycle)

Cycle 110 GMT 2/12/2021 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.76 31 15.17 612 288 0.29 / 481.78 2 2
2 3 968.80 -1 15.55 7 0 0.00 / 481.78 2 2
3 7 2003.20 30 15.12 2947 1337 1.62 / 483.12 2 3
4 13 1589.48 29 15.07 2453 1072 2.70 / 484.19 2 3
5 13 801.28 29 15.14 1446 635 3.33 / 484.82 2 4
6 8 0.24 175 15.25 377 1006 4.34 / 485.83 2 13
7 14 0.24 20 15.22 378 115 4.45 / 485.94 3 14
Average= 4.38
(KJ/cycle)

Cycle 109 GMT 22/11/2021 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.12 30 15.17 611 278 0.28 / 477.21 2 2
2 10 1003.76 3 15.18 1777 81 0.36 / 477.30 2 3
3 3 969.92 -1 15.55 7 0 0.08 / 477.30 2 3
4 7 2002.68 31 15.12 2949 1382 1.74 / 478.68 2 2
5 13 1588.08 29 15.07 2441 1067 2.81 / 479.74 2 3
6 13 794.88 29 15.13 1451 637 3.44 / 480.38 2 4
7 8 0.00 175 15.25 373 995 4.44 / 481.38 2 17
8 14 0.00 20 15.23 378 115 4.56 / 481.49 2 12
Average= 4.38
(KJ/cycle)

Cycle 108 GMT 12/11/2021 11:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.64 30 15.16 617 281 0.28 / 472.75 2 2
2 7 2005.80 30 15.14 2956 1343 1.62 / 474.10 2 2
3 13 1731.84 29 15.07 2625 1147 2.77 / 475.24 2 4
4 13 800.88 29 15.14 1459 641 3.41 / 475.88 2 5
5 13 18.96 3 15.31 447 21 3.43 / 475.90 2 2
6 8 0.12 175 15.25 387 1033 4.46 / 476.94 2 11
Average= 4.38
(KJ/cycle)

Cycle 107 GMT 2/11/2021 13:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.40 30 15.17 603 274 0.27 / 468.19 2 2
2 7 2003.40 30 15.12 2950 1338 1.61 / 469.53 2 2
3 13 1594.16 29 15.07 2465 1077 2.69 / 470.61 2 4
4 13 826.40 29 15.13 1489 653 3.34 / 471.26 2 5
5 13 15.88 29 15.28 434 192 3.54 / 471.45 2 5
6 8 0.20 175 15.23 383 1021 4.56 / 472.47 2 15
Average= 4.37
(KJ/cycle)

Cycle 106 GMT 23/10/2021 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.16 30 15.16 615 280 0.28 / 463.77 2 2
2 3 1015.88 1 15.29 1826 28 0.31 / 463.80 2 2
3 7 2004.48 31 15.12 2949 1382 1.69 / 465.18 2 3
4 13 1591.52 29 15.08 2448 1071 2.76 / 466.25 2 3
5 13 792.72 29 15.14 1445 634 3.39 / 466.89 2 5
6 8 0.08 175 15.25 386 1030 4.43 / 467.92 2 9
Average= 4.37
(KJ/cycle)

Cycle 105 GMT 13/10/2021 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.76 30 15.16 625 284 0.28 / 459.41 2 2
2 7 2002.00 30 15.13 2939 1334 1.62 / 460.75 2 2
3 13 1466.32 29 15.09 2298 1006 2.62 / 461.75 2 3
4 13 716.64 29 15.15 1345 591 3.21 / 462.35 2 4
5 8 -0.04 175 15.24 385 1027 4.24 / 463.37 2 15
6 14 -0.04 20 15.21 392 119 4.36 / 463.49 2 13
Average= 4.37
(KJ/cycle)

Cycle 104 GMT 3/10/2021 19:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.72 30 15.17 625 284 0.28 / 454.97 2 3
2 3 982.60 -1 15.55 8 0 0.00 / 454.97 2 3
3 7 2002.72 30 15.13 2951 1339 1.62 / 456.31 2 2
4 13 1596.12 29 15.08 2458 1075 2.70 / 457.38 2 3
5 13 812.80 29 15.13 1486 652 3.35 / 458.04 2 5
6 13 52.64 5 15.29 507 39 3.39 / 458.07 2 4
7 8 0.16 175 15.24 396 1056 4.45 / 459.13 2 11
Average= 4.37
(KJ/cycle)

Cycle 103 GMT 23/ 9/2021 22: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.76 30 15.17 612 279 0.28 / 450.64 2 3
2 3 969.56 -1 15.56 8 0 0.00 / 450.64 2 3
3 7 2003.40 30 15.12 2942 1334 1.61 / 451.97 2 2
4 13 1594.08 29 15.08 2445 1069 2.68 / 453.04 2 5
5 13 784.80 29 15.15 1424 626 3.31 / 453.67 2 4
6 8 0.00 175 15.25 381 1017 4.32 / 454.68 2 13
Average= 4.37
(KJ/cycle)

Cycle 102 GMT 14/ 9/2021 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.20 29 15.16 608 267 0.27 / 446.22 2 3
2 10 1001.12 2 15.16 1789 54 0.32 / 446.28 2 3
3 3 976.72 -1 15.55 8 0 0.05 / 446.28 2 3
4 7 2009.16 30 15.13 2954 1341 1.66 / 447.62 2 2
5 13 1605.76 29 15.08 2471 1081 2.74 / 448.70 2 3
6 13 802.44 29 15.14 1471 646 3.39 / 449.35 2 4
7 8 0.40 175 15.25 380 1014 4.40 / 450.36 2 13
Average= 4.37
(KJ/cycle)

Cycle 101 GMT 4/ 9/2021 2:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.92 29 15.17 596 262 0.26 / 441.52 2 2
2 7 2009.76 31 15.13 2945 1381 1.64 / 442.90 2 2
3 13 1601.04 29 15.08 2455 1074 2.72 / 443.97 2 3
4 13 815.04 29 15.14 1484 652 3.37 / 444.62 2 5
5 13 20.20 5 15.30 448 34 3.40 / 444.66 2 3
6 13 19.64 29 15.28 425 188 3.59 / 444.85 2 4
7 8 -0.28 175 15.24 374 997 4.59 / 445.84 2 18
8 14 -0.28 20 15.21 375 114 4.70 / 445.96 2 11
Average= 4.37
(KJ/cycle)

Cycle 100 GMT 25/ 8/2021 4:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.68 29 15.17 631 278 0.28 / 437.08 2 3
2 7 2002.16 30 15.13 2949 1339 1.62 / 438.42 2 2
3 13 1591.40 29 15.09 2452 1073 2.69 / 439.49 2 3
4 13 685.88 29 15.17 1305 574 3.26 / 440.07 2 4
5 13 16.56 29 15.29 417 185 3.45 / 440.25 2 5
6 8 0.24 175 15.25 376 1003 4.45 / 441.25 2 13
Average= 4.37
(KJ/cycle)

Cycle 99 GMT 15/ 8/2021 6:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.80 29 15.18 609 268 0.27 / 432.77 2 3
2 7 2004.48 30 15.12 2956 1341 1.61 / 434.11 2 3
3 13 1587.04 29 15.08 2460 1076 2.68 / 435.18 2 3
4 13 676.60 29 15.16 1319 580 3.26 / 435.76 2 3
5 8 -0.08 175 15.25 389 1038 4.30 / 436.80 2 11
Average= 4.37
(KJ/cycle)

Cycle 98 GMT 5/ 8/2021 8:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.96 29 15.17 644 283 0.28 / 428.52 2 3
2 7 2003.56 30 15.12 2955 1340 1.62 / 429.86 2 3
3 13 1586.76 29 15.08 2459 1075 2.70 / 430.93 2 4
4 13 656.28 29 15.17 1283 564 3.26 / 431.50 2 4
5 8 0.72 175 15.26 376 1004 4.27 / 432.50 2 16
Average= 4.37
(KJ/cycle)

Cycle 97 GMT 26/ 7/2021 10:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.84 30 15.17 626 285 0.28 / 424.12 2 2
2 7 2004.92 30 15.12 2949 1338 1.62 / 425.46 2 3
3 13 1602.92 29 15.07 2481 1084 2.71 / 426.54 2 3
4 13 793.52 29 15.14 1466 644 3.35 / 427.19 2 4
5 8 -0.16 175 15.26 392 1047 4.40 / 428.23 2 12
Average= 4.37
(KJ/cycle)

Cycle 96 GMT 16/ 7/2021 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.56 30 15.19 598 273 0.27 / 419.65 2 2
2 3 983.88 -1 15.56 7 0 0.00 / 419.65 2 2
3 7 2005.16 30 15.13 2947 1338 1.61 / 420.99 2 3
4 13 1598.48 29 15.08 2462 1077 2.69 / 422.07 2 4
5 13 807.56 29 15.14 1478 649 3.34 / 422.71 2 5
6 13 19.12 13 15.30 437 87 3.42 / 422.80 2 5
7 8 0.20 175 15.25 387 1033 4.46 / 423.83 2 13
Average= 4.37
(KJ/cycle)

Cycle 95 GMT 6/ 7/2021 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.12 29 15.18 616 271 0.27 / 415.30 2 2
2 3 1046.20 1 15.27 1870 29 0.30 / 415.32 2 3
3 7 2003.32 30 15.13 2955 1341 1.64 / 416.67 2 3
4 13 1597.20 29 15.08 2466 1078 2.72 / 417.74 2 4
5 13 788.04 29 15.15 1446 635 3.35 / 418.38 2 4
6 8 0.20 175 15.27 374 999 4.35 / 419.38 2 9
Average= 4.37
(KJ/cycle)

Cycle 94 GMT 26/ 6/2021 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.00 29 15.18 643 283 0.28 / 410.77 2 3
2 3 1028.36 1 15.28 1849 28 0.31 / 410.80 2 2
3 7 2001.92 30 15.13 2946 1337 1.65 / 412.14 2 2
4 13 1719.52 29 15.08 2613 1143 2.79 / 413.28 2 3
5 13 768.76 29 15.16 1411 620 3.41 / 413.90 2 6
6 8 0.52 175 15.27 378 1010 4.42 / 414.91 2 9
7 14 0.52 20 15.24 383 117 4.54 / 415.03 2 11
Average= 4.37
(KJ/cycle)

Cycle 93 GMT 16/ 6/2021 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.12 28 15.18 622 264 0.26 / 406.29 2 3
2 3 1017.84 1 15.30 1850 28 0.29 / 406.32 2 2
3 7 2007.60 30 15.14 2963 1346 1.64 / 407.67 2 2
4 13 1585.80 29 15.08 2450 1071 2.71 / 408.74 2 3
5 13 789.80 29 15.15 1463 643 3.35 / 409.38 2 4
6 13 47.92 5 15.31 499 38 3.39 / 409.42 2 4
7 8 -0.44 175 15.26 400 1068 4.46 / 410.49 2 7
Average= 4.37
(KJ/cycle)

Cycle 92 GMT 6/ 6/2021 21:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.72 28 15.17 654 278 0.28 / 401.97 2 3
2 7 2002.68 30 15.14 2952 1341 1.62 / 403.31 2 3
3 13 1603.68 29 15.08 2480 1085 2.70 / 404.39 2 3
4 13 697.80 29 15.17 1338 589 3.29 / 404.98 2 5
5 8 0.20 175 15.26 392 1047 4.34 / 406.03 2 12
Average= 4.37
(KJ/cycle)

Cycle 91 GMT 27/ 5/2021 23:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.96 28 15.17 654 278 0.28 / 397.63 2 3
2 7 2003.40 30 15.13 2957 1342 1.62 / 398.97 2 4
3 13 1594.36 29 15.07 2462 1076 2.70 / 400.05 2 3
4 13 650.04 29 15.18 1293 569 3.27 / 400.62 2 4
5 8 0.12 175 15.26 402 1074 4.34 / 401.69 2 10
Average= 4.37
(KJ/cycle)

Cycle 90 GMT 18/ 5/2021 1:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.88 28 15.17 639 271 0.27 / 393.27 2 3
2 7 2005.68 31 15.12 2959 1387 1.66 / 394.66 2 3
3 13 1581.04 29 15.08 2444 1069 2.73 / 395.72 2 3
4 13 650.72 29 15.18 1292 569 3.30 / 396.29 2 4
5 8 0.28 175 15.26 396 1058 4.35 / 397.35 2 12
Average= 4.37
(KJ/cycle)

Cycle 89 GMT 8/ 5/2021 3:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.52 28 15.18 647 275 0.28 / 388.76 2 3
2 3 1021.00 1 15.28 1842 28 0.30 / 388.78 2 2
3 7 2001.84 30 15.13 2970 1348 1.65 / 390.13 2 2
4 13 1594.48 29 15.08 2469 1080 2.73 / 391.21 2 3
5 13 644.28 29 15.18 1281 564 3.29 / 391.78 2 4
6 13 47.68 5 15.31 499 38 3.33 / 391.81 2 4
7 8 -0.48 175 15.26 398 1063 4.40 / 392.88 2 13
8 14 -0.48 20 15.24 395 120 4.52 / 393.00 2 13
Average= 4.37
(KJ/cycle)

Cycle 88 GMT 28/ 4/2021 5:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.88 28 15.18 639 272 0.27 / 384.43 2 3
2 7 2002.52 30 15.14 2949 1339 1.61 / 385.77 2 3
3 13 1589.44 29 15.08 2461 1076 2.69 / 386.85 2 3
4 13 649.52 29 15.19 1281 564 3.25 / 387.41 2 4
5 8 0.44 175 15.26 399 1066 4.32 / 388.48 2 13
Average= 4.36
(KJ/cycle)

Cycle 87 GMT 18/ 4/2021 8: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.44 28 15.18 622 264 0.26 / 380.15 2 3
2 7 2006.68 30 15.13 2963 1345 1.61 / 381.49 2 2
3 13 1604.16 29 15.07 2474 1081 2.69 / 382.57 2 5
4 13 660.32 29 15.18 1287 567 3.26 / 383.14 2 5
5 8 0.16 175 15.26 384 1025 4.28 / 384.16 2 13
Average= 4.37
(KJ/cycle)

Cycle 86 GMT 8/ 4/2021 10: 3:14

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.80 28 15.17 650 276 0.28 / 375.86 2 3
2 7 2003.56 30 15.12 2969 1347 1.62 / 377.21 2 2
3 13 1576.32 29 15.08 2450 1071 2.69 / 378.28 2 3
4 13 619.64 29 15.19 1240 546 3.24 / 378.83 2 4
5 8 0.32 175 15.27 394 1053 4.29 / 379.88 2 15
Average= 4.37
(KJ/cycle)

Cycle 85 GMT 29/ 3/2021 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.96 28 15.17 645 274 0.27 / 371.57 2 3
2 7 2003.08 30 15.12 2950 1338 1.61 / 372.91 2 3
3 13 1467.72 29 15.10 2296 1005 2.62 / 373.91 2 3
4 13 699.32 29 15.17 1350 594 3.21 / 374.51 2 4
5 8 0.04 175 15.26 404 1079 4.29 / 375.59 2 15
Average= 4.37
(KJ/cycle)

Cycle 84 GMT 19/ 3/2021 14:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.16 28 15.18 604 257 0.26 / 367.35 2 2
2 3 982.92 -1 15.56 6 0 0.00 / 367.35 2 2
3 7 2008.44 30 15.12 2969 1347 1.60 / 368.70 2 3
4 13 1461.96 29 15.09 2303 1008 2.61 / 369.70 2 5
5 13 580.60 29 15.19 1206 531 3.14 / 370.23 2 4
6 8 -0.16 175 15.26 398 1063 4.21 / 371.30 2 6
Average= 4.37
(KJ/cycle)

Cycle 83 GMT 9/ 3/2021 16:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.32 28 15.18 647 275 0.28 / 362.92 2 2
2 7 2005.44 30 15.12 2961 1343 1.62 / 364.26 2 2
3 13 1452.04 29 15.10 2282 999 2.62 / 365.26 2 6
4 13 675.64 29 15.18 1306 575 3.19 / 365.84 2 5
5 13 30.52 29 15.30 455 202 3.39 / 366.04 2 5
6 8 -0.20 175 15.25 394 1051 4.45 / 367.09 2 13
Average= 4.37
(KJ/cycle)

Cycle 82 GMT 27/ 2/2021 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.96 28 15.25 644 275 0.27 / 358.50 2 3
2 10 1030.32 4 15.20 1836 112 0.39 / 358.61 2 3
3 3 864.16 -5 15.57 7 0 0.11 / 358.61 2 3
4 3 1021.72 1 15.32 1836 28 0.41 / 358.64 2 2
5 7 2005.08 30 15.11 2975 1349 1.76 / 359.98 2 2
6 13 1446.92 29 15.09 2297 1005 2.77 / 360.99 2 3
7 13 660.68 29 15.18 1305 574 3.34 / 361.56 2 4
8 8 0.24 175 15.26 405 1082 4.42 / 362.65 2 12
Average= 4.37
(KJ/cycle)

Cycle 81 GMT 17/ 2/2021 20:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.76 28 15.18 651 277 0.28 / 354.76 2 2
2 7 1241.04 30 15.35 2018 929 1.21 / 355.69 2 4
3 13 1163.80 29 15.28 1933 857 2.06 / 356.55 2 5
4 13 690.36 29 15.29 1325 588 2.65 / 357.13 2 5
5 8 0.08 175 15.34 405 1087 3.74 / 358.22 2 16
Average= 4.37
(KJ/cycle)

Cycle 80 GMT 7/ 2/2021 21:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.96 28 15.19 637 271 0.27 / 350.19 2 3
2 7 2006.92 30 15.14 2967 1348 1.62 / 351.54 2 3
3 13 1597.44 29 15.09 2473 1082 2.70 / 352.62 2 4
4 13 675.56 29 15.19 1320 581 3.28 / 353.20 2 5
5 13 36.56 29 15.30 476 211 3.49 / 353.41 2 5
6 8 0.08 175 15.25 401 1070 4.56 / 354.48 2 18
Average= 4.38
(KJ/cycle)

Cycle 79 GMT 28/ 1/2021 23:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.76 28 15.20 636 271 0.27 / 345.90 2 3
2 7 2004.16 30 15.13 2968 1347 1.62 / 347.25 2 3
3 13 1585.00 29 15.09 2453 1073 2.69 / 348.32 2 4
4 13 645.08 29 15.19 1279 563 3.25 / 348.89 2 5
5 8 -0.04 175 15.27 387 1034 4.29 / 349.92 2 13
Average= 4.37
(KJ/cycle)

Cycle 78 GMT 19/ 1/2021 1:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.36 28 15.20 645 275 0.27 / 341.49 2 2
2 7 2007.28 31 15.13 2967 1392 1.67 / 342.88 2 3
3 13 1597.04 29 15.09 2455 1074 2.74 / 343.95 2 3
4 13 780.72 29 15.17 1439 633 3.37 / 344.58 2 5
5 8 0.52 175 15.27 392 1048 4.42 / 345.63 2 13
Average= 4.38
(KJ/cycle)

Cycle 77 GMT 9/ 1/2021 3:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.08 28 15.20 599 255 0.25 / 337.17 2 2
2 7 2003.56 30 15.13 2958 1343 1.60 / 338.51 2 2
3 13 1585.48 29 15.10 2443 1070 2.67 / 339.58 2 3
4 13 640.40 29 15.20 1270 560 3.23 / 340.14 2 4
5 8 -0.24 175 15.28 401 1072 4.30 / 341.21 2 10
Average= 4.37
(KJ/cycle)

Cycle 76 GMT 30/12/2020 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.32 28 15.19 632 269 0.27 / 332.85 2 3
2 7 2003.40 30 15.15 2966 1348 1.62 / 334.20 2 2
3 13 1593.88 29 15.10 2463 1079 2.70 / 335.28 2 3
4 13 651.80 29 15.20 1284 566 3.26 / 335.85 2 4
5 8 0.04 175 15.28 398 1064 4.33 / 336.91 2 12
Average= 4.38
(KJ/cycle)

Cycle 75 GMT 20/12/2020 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.72 29 15.19 650 286 0.29 / 328.40 2 3
2 7 2007.08 30 15.14 2965 1347 1.63 / 329.74 2 4
3 13 1589.88 29 15.09 2474 1083 2.72 / 330.83 2 5
4 13 645.60 29 15.20 1275 562 3.28 / 331.39 2 4
5 8 0.12 175 15.28 401 1072 4.35 / 332.46 2 14
6 14 0.12 20 15.25 410 125 4.48 / 332.59 2 15
Average= 4.38
(KJ/cycle)

Cycle 74 GMT 10/12/2020 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.76 28 15.20 631 269 0.27 / 324.02 2 3
2 7 2004.76 30 15.15 2972 1351 1.62 / 325.37 2 2
3 13 1594.04 29 15.10 2469 1081 2.70 / 326.45 2 3
4 13 677.72 29 15.20 1326 585 3.29 / 327.04 2 4
5 8 0.24 175 15.28 402 1075 4.36 / 328.11 2 12
Average= 4.37
(KJ/cycle)

Cycle 73 GMT 30/11/2020 11:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.08 29 15.21 641 283 0.28 / 319.60 2 3
2 3 985.44 -1 15.58 7 0 0.00 / 319.60 2 3
3 7 2003.00 30 15.16 2967 1349 1.63 / 320.95 2 3
4 13 1593.72 29 15.10 2468 1081 2.71 / 322.03 2 4
5 13 797.60 29 15.18 1470 647 3.36 / 322.68 2 4
6 8 0.08 175 15.28 401 1072 4.43 / 323.75 2 11
Average= 4.38
(KJ/cycle)

Cycle 72 GMT 20/11/2020 13:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.96 29 15.20 631 278 0.28 / 315.14 2 2
2 7 2003.28 30 15.16 2952 1343 1.62 / 316.48 2 3
3 13 1733.96 29 15.08 2638 1154 2.77 / 317.64 2 4
4 13 742.12 29 15.20 1396 615 3.39 / 318.25 2 4
5 8 0.08 175 15.29 399 1068 4.46 / 319.32 2 14
Average= 4.37
(KJ/cycle)

Cycle 71 GMT 10/11/2020 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.52 29 15.21 632 279 0.28 / 310.52 2 3
2 7 2004.44 30 15.15 2953 1342 1.62 / 311.86 2 3
3 13 1609.28 29 15.10 2500 1095 2.72 / 312.96 2 3
4 13 781.16 29 15.18 1456 641 3.36 / 313.60 2 5
5 13 27.12 29 15.32 449 199 3.56 / 313.80 2 5
6 8 0.20 175 15.27 397 1061 4.62 / 314.86 2 11
Average= 4.37
(KJ/cycle)

Cycle 70 GMT 31/10/2020 17:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.32 29 15.21 638 281 0.28 / 306.22 2 3
2 7 2003.40 30 15.15 2951 1341 1.62 / 307.56 2 3
3 13 1586.32 29 15.11 2451 1074 2.70 / 308.63 2 3
4 13 672.48 29 15.21 1314 580 3.28 / 309.21 2 5
5 8 0.20 175 15.29 385 1030 4.31 / 310.24 2 12
Average= 4.37
(KJ/cycle)

Cycle 69 GMT 21/10/2020 19:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.64 29 15.20 646 285 0.28 / 301.82 2 3
2 7 2005.48 30 15.17 2959 1347 1.63 / 303.17 2 3
3 13 1597.96 29 15.12 2471 1083 2.71 / 304.25 2 4
4 13 789.00 29 15.19 1448 638 3.35 / 304.89 2 5
5 8 -0.04 175 15.30 392 1050 4.40 / 305.94 2 16
Average= 4.37
(KJ/cycle)

Cycle 68 GMT 11/10/2020 21:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.16 29 15.22 633 279 0.28 / 297.33 2 3
2 7 2005.24 30 15.16 2961 1347 1.63 / 298.67 2 3
3 13 1597.80 29 15.11 2473 1084 2.71 / 299.76 2 3
4 13 672.16 29 15.21 1297 572 3.28 / 300.33 2 4
5 8 0.16 175 15.29 404 1081 4.36 / 301.41 2 11
6 14 0.16 20 15.26 410 125 4.49 / 301.54 2 12
Average= 4.37
(KJ/cycle)

Cycle 67 GMT 1/10/2020 23:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.80 29 15.19 644 284 0.28 / 292.95 2 3
2 7 2006.96 30 15.16 2969 1350 1.63 / 294.30 2 2
3 13 1581.36 29 15.12 2449 1074 2.71 / 295.37 2 4
4 13 764.80 29 15.20 1416 624 3.33 / 296.00 2 5
5 8 0.16 175 15.30 393 1052 4.38 / 297.05 2 12
Average= 4.37
(KJ/cycle)

Cycle 66 GMT 22/ 9/2020 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.68 29 15.21 646 285 0.28 / 288.27 2 3
2 7 2008.16 30 15.17 2961 1348 1.63 / 289.62 2 2
3 13 1608.52 29 15.11 2493 1092 2.72 / 290.71 2 4
4 13 823.40 29 15.18 1491 656 3.38 / 291.37 2 4
5 13 67.28 29 15.32 511 227 3.61 / 291.60 2 5
6 8 0.00 175 15.28 399 1067 4.68 / 292.66 2 15
Average= 4.37
(KJ/cycle)

Cycle 65 GMT 12/ 9/2020 3:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.20 29 15.22 626 276 0.28 / 283.81 2 3
2 7 2002.20 30 15.17 2964 1349 1.63 / 285.16 2 3
3 13 1606.64 29 15.11 2490 1091 2.72 / 286.25 2 3
4 13 806.48 29 15.19 1489 656 3.37 / 286.91 2 6
5 8 -0.04 175 15.29 404 1081 4.45 / 287.99 2 13
Average= 4.36
(KJ/cycle)

Cycle 64 GMT 2/ 9/2020 5:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.96 29 15.22 639 282 0.28 / 279.35 2 3
2 7 2002.36 31 15.16 2963 1392 1.67 / 280.74 2 2
3 13 1592.84 29 15.11 2469 1082 2.76 / 281.82 2 3
4 13 782.76 29 15.20 1448 638 3.39 / 282.46 2 4
5 8 0.04 175 15.30 402 1076 4.47 / 283.53 2 12
Average= 4.36
(KJ/cycle)

Cycle 63 GMT 23/ 8/2020 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.36 29 15.22 631 279 0.28 / 274.96 2 3
2 7 2005.84 30 15.16 2965 1348 1.63 / 276.31 2 3
3 13 1597.80 29 15.12 2493 1093 2.72 / 277.40 2 4
4 13 667.24 29 15.22 1318 582 3.30 / 277.98 2 4
5 8 0.24 175 15.30 404 1082 4.38 / 279.06 2 14
Average= 4.36
(KJ/cycle)

Cycle 62 GMT 13/ 8/2020 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.72 29 15.22 638 282 0.28 / 270.29 2 3
2 7 2006.12 31 15.17 2954 1389 1.67 / 271.68 2 3
3 13 1592.28 29 15.12 2475 1085 2.76 / 272.77 2 3
4 13 775.44 29 15.20 1450 639 3.40 / 273.41 2 5
5 13 50.48 29 15.33 484 215 3.61 / 273.62 2 5
6 8 -0.12 175 15.29 396 1060 4.67 / 274.68 2 9
Average= 4.36
(KJ/cycle)

Cycle 61 GMT 3/ 8/2020 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.40 29 15.23 636 281 0.28 / 265.72 2 2
2 7 2006.32 30 15.17 2968 1351 1.63 / 267.07 2 2
3 13 1591.36 29 15.12 2470 1083 2.71 / 268.15 2 2
4 13 661.80 29 15.23 1305 576 3.29 / 268.73 2 4
5 13 35.72 29 15.34 474 211 3.50 / 268.94 2 5
6 8 0.12 175 15.29 401 1073 4.57 / 270.01 2 12
Average= 4.36
(KJ/cycle)

Cycle 60 GMT 24/ 7/2020 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.76 29 15.24 609 269 0.27 / 261.31 2 3
2 7 2002.16 30 15.17 2962 1348 1.62 / 262.65 2 2
3 13 1578.80 29 15.13 2466 1082 2.70 / 263.74 2 3
4 13 760.48 29 15.20 1436 633 3.33 / 264.37 2 3
5 8 -0.04 175 15.31 398 1066 4.40 / 265.44 2 12
Average= 4.35
(KJ/cycle)

Cycle 59 GMT 14/ 7/2020 16:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.80 28 15.23 623 266 0.27 / 256.86 2 2
2 7 2002.40 31 15.17 2964 1394 1.66 / 258.26 2 2
3 13 1576.24 29 15.13 2455 1077 2.74 / 259.33 2 2
4 13 778.40 29 15.21 1461 644 3.38 / 259.98 2 3
5 8 0.32 175 15.32 395 1059 4.44 / 261.04 2 10
Average= 4.35
(KJ/cycle)

Cycle 58 GMT 4/ 7/2020 18:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.40 28 15.25 631 269 0.27 / 252.30 2 2
2 7 2007.36 30 15.17 2960 1347 1.62 / 253.65 2 2
3 13 1584.24 29 15.13 2465 1082 2.70 / 254.73 2 2
4 13 657.60 29 15.23 1315 581 3.28 / 255.31 2 4
5 13 41.08 29 15.34 485 216 3.49 / 255.53 2 5
6 8 0.36 175 15.30 399 1068 4.56 / 256.60 2 12
Average= 4.35
(KJ/cycle)

Cycle 57 GMT 24/ 6/2020 20:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.92 28 15.24 613 262 0.26 / 247.97 2 2
2 7 2005.36 30 15.17 2966 1350 1.61 / 249.32 2 2
3 13 1585.40 29 15.13 2462 1080 2.69 / 250.40 2 2
4 13 645.68 29 15.24 1281 566 3.26 / 250.96 2 4
5 8 -0.12 175 15.32 399 1070 4.33 / 252.03 2 11
Average= 4.35
(KJ/cycle)

Cycle 56 GMT 14/ 6/2020 22:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.04 28 15.23 642 274 0.27 / 243.51 2 2
2 7 2004.36 30 15.17 2975 1354 1.63 / 244.86 2 2
3 13 1592.64 29 15.13 2474 1086 2.71 / 245.95 2 2
4 13 663.00 29 15.24 1299 574 3.29 / 246.52 2 4
5 8 0.36 175 15.32 396 1062 4.35 / 247.58 2 12
6 14 0.36 20 15.30 404 124 4.47 / 247.71 2 13
Average= 4.35
(KJ/cycle)

Cycle 55 GMT 5/ 6/2020 0:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.36 28 15.25 646 276 0.28 / 238.92 2 2
2 7 2003.44 30 15.18 2968 1352 1.63 / 240.27 2 2
3 13 1597.92 29 15.13 2487 1091 2.72 / 241.36 2 2
4 13 686.00 29 15.24 1347 595 3.31 / 241.96 2 3
5 13 19.24 29 15.36 454 202 3.52 / 242.16 2 5
6 8 0.44 175 15.31 400 1072 4.59 / 243.23 2 15
Average= 4.34
(KJ/cycle)

Cycle 54 GMT 26/ 5/2020 2:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.40 28 15.24 641 274 0.27 / 234.46 2 2
2 7 2006.28 30 15.19 2968 1353 1.63 / 235.81 2 2
3 13 1587.60 29 15.14 2466 1083 2.71 / 236.89 2 3
4 13 672.56 29 15.24 1332 589 3.30 / 237.48 2 3
5 8 -0.16 175 15.33 388 1041 4.34 / 238.52 2 14
6 14 -0.16 20 15.30 403 123 4.46 / 238.65 2 14
Average= 4.34
(KJ/cycle)

Cycle 53 GMT 16/ 5/2020 4:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.04 28 15.26 636 272 0.27 / 229.90 2 2
2 7 2003.84 30 15.19 2965 1351 1.62 / 231.25 2 2
3 13 1604.40 29 15.13 2485 1090 2.71 / 232.35 2 2
4 13 687.28 29 15.24 1337 591 3.30 / 232.94 2 3
5 13 41.76 29 15.35 472 210 3.51 / 233.15 2 5
6 8 0.28 175 15.32 387 1038 4.55 / 234.18 2 17
Average= 4.34
(KJ/cycle)

Cycle 52 GMT 6/ 5/2020 6:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.44 28 15.26 623 266 0.27 / 225.50 2 2
2 7 2004.64 30 15.19 2976 1356 1.62 / 226.85 2 2
3 13 1586.84 29 15.14 2466 1083 2.71 / 227.94 2 2
4 13 779.84 29 15.22 1455 642 3.35 / 228.58 2 3
5 8 0.20 175 15.33 393 1054 4.40 / 229.63 2 12
Average= 4.33
(KJ/cycle)

Cycle 51 GMT 26/ 4/2020 8:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.12 28 15.25 645 275 0.28 / 221.17 2 2
2 7 2002.00 30 15.18 2965 1350 1.63 / 222.52 2 2
3 13 1581.64 29 15.14 2456 1078 2.70 / 223.60 2 2
4 13 641.28 29 15.25 1288 570 3.27 / 224.17 2 4
5 8 0.20 175 15.33 395 1060 4.33 / 225.23 2 16
Average= 4.33
(KJ/cycle)

Cycle 50 GMT 16/ 4/2020 10:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.16 28 15.25 655 280 0.28 / 216.54 2 2
2 7 2005.04 30 15.18 2973 1354 1.63 / 217.89 2 2
3 13 1578.08 29 15.15 2460 1081 2.71 / 218.98 2 2
4 13 764.32 29 15.23 1449 640 3.35 / 219.62 2 3
5 13 24.00 29 15.37 470 209 3.56 / 219.82 2 5
6 8 -0.48 175 15.32 400 1072 4.64 / 220.90 2 18
Average= 4.33
(KJ/cycle)

Cycle 49 GMT 6/ 4/2020 12:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.44 28 15.25 634 271 0.27 / 211.91 2 2
2 7 2003.12 30 15.19 2972 1354 1.63 / 213.26 2 2
3 13 1588.48 29 15.14 2482 1090 2.71 / 214.35 2 2
4 13 765.80 29 15.23 1444 638 3.35 / 214.99 2 3
5 13 22.88 29 15.37 455 203 3.56 / 215.19 2 5
6 8 0.24 175 15.32 398 1067 4.62 / 216.26 2 14
Average= 4.33
(KJ/cycle)

Cycle 48 GMT 27/ 3/2020 14:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.56 28 15.26 628 268 0.27 / 207.32 2 2
2 7 2006.44 30 15.19 2964 1351 1.62 / 208.67 2 2
3 13 1584.60 29 15.15 2466 1083 2.70 / 209.75 2 2
4 13 668.28 29 15.25 1326 586 3.29 / 210.34 2 3
5 13 39.56 29 15.36 492 219 3.51 / 210.56 2 5
6 8 0.20 175 15.32 404 1083 4.59 / 211.64 2 13
Average= 4.32
(KJ/cycle)

Cycle 47 GMT 17/ 3/2020 16:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.68 28 15.25 646 276 0.28 / 202.68 2 2
2 7 2005.92 30 15.20 2983 1360 1.64 / 204.04 2 2
3 13 1597.40 29 15.15 2488 1093 2.73 / 205.13 2 2
4 13 783.96 29 15.24 1470 650 3.38 / 205.78 2 3
5 13 27.20 29 15.37 465 207 3.59 / 205.99 2 5
6 8 0.12 175 15.33 394 1057 4.64 / 207.05 2 14
Average= 4.31
(KJ/cycle)

Cycle 46 GMT 7/ 3/2020 18:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.80 28 15.27 658 281 0.28 / 197.95 2 2
2 7 2007.64 30 15.20 2985 1361 1.64 / 199.31 2 2
3 13 1600.84 29 15.15 2493 1095 2.74 / 200.41 2 2
4 13 672.24 29 15.26 1326 587 3.32 / 200.99 2 3
5 13 36.76 29 15.37 476 212 3.54 / 201.21 2 5
6 8 -0.20 175 15.33 399 1070 4.61 / 202.28 2 15
7 14 -0.20 20 15.31 415 127 4.73 / 202.40 2 12
Average= 4.31
(KJ/cycle)

Cycle 45 GMT 26/ 2/2020 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.04 28 15.26 646 276 0.28 / 193.57 2 2
2 7 2005.24 30 15.19 2961 1349 1.63 / 194.92 2 2
3 13 1580.52 29 15.16 2459 1081 2.71 / 196.00 2 2
4 13 640.48 29 15.27 1286 569 3.28 / 196.57 2 4
5 8 0.40 175 15.34 411 1103 4.38 / 197.67 2 11
Average= 4.30
(KJ/cycle)

Cycle 44 GMT 16/ 2/2020 22:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.88 28 15.27 657 281 0.28 / 188.91 2 2
2 7 2007.48 30 15.19 2967 1352 1.63 / 190.26 2 2
3 13 1592.96 29 15.15 2481 1090 2.72 / 191.35 2 3
4 13 770.04 29 15.24 1450 641 3.36 / 191.99 2 3
5 13 48.80 29 15.37 491 219 3.58 / 192.21 2 5
6 8 0.00 175 15.33 403 1081 4.66 / 193.29 2 14
Average= 4.30
(KJ/cycle)

Cycle 43 GMT 7/ 2/2020 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.36 28 15.27 663 283 0.28 / 184.50 2 2
2 7 2002.44 30 15.20 2967 1353 1.64 / 185.85 2 2
3 13 1592.60 29 15.16 2473 1087 2.72 / 186.94 2 2
4 13 643.04 29 15.27 1282 568 3.29 / 187.51 2 4
5 8 0.24 175 15.35 416 1117 4.41 / 188.63 2 12
Average= 4.29
(KJ/cycle)

Cycle 42 GMT 28/ 1/2020 3: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.64 28 15.27 671 287 0.29 / 179.97 2 2
2 7 2004.24 30 15.20 2965 1352 1.64 / 181.32 2 2
3 13 1587.44 29 15.16 2486 1093 2.73 / 182.41 2 2
4 13 644.04 29 15.28 1280 567 3.30 / 182.98 2 4
5 8 -0.08 175 15.35 412 1107 4.41 / 184.09 2 13
6 14 -0.08 20 15.32 422 129 4.54 / 184.22 2 16
Average= 4.28
(KJ/cycle)

Cycle 41 GMT 18/ 1/2020 5: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 153.24 28 15.27 646 276 0.28 / 175.34 2 2
2 7 2003.20 30 15.21 2981 1360 1.64 / 176.70 2 2
3 13 1584.40 29 15.17 2474 1088 2.72 / 177.79 2 2
4 13 664.36 29 15.27 1326 587 3.31 / 178.38 2 4
5 13 40.52 5 15.40 506 39 3.35 / 178.42 2 4
6 8 0.48 175 15.35 422 1134 4.48 / 179.55 2 9
7 14 0.48 20 15.32 424 130 4.61 / 179.68 2 14
Average= 4.28
(KJ/cycle)

Cycle 40 GMT 8/ 1/2020 6:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.16 28 15.28 635 272 0.27 / 170.80 2 2
2 7 2003.96 30 15.21 2975 1357 1.63 / 172.15 2 2
3 13 1598.20 29 15.16 2490 1095 2.72 / 173.25 2 2
4 13 790.20 29 15.25 1478 654 3.38 / 173.90 2 3
5 13 46.08 5 15.40 517 40 3.42 / 173.94 2 4
6 8 -0.04 175 15.35 419 1126 4.54 / 175.07 2 12
Average= 4.27
(KJ/cycle)

Cycle 39 GMT 29/12/2019 9: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.92 28 15.27 644 275 0.28 / 166.27 2 2
2 7 2004.60 30 15.20 2980 1359 1.63 / 167.63 2 2
3 13 1587.00 29 15.16 2477 1089 2.72 / 168.72 2 2
4 13 642.72 29 15.28 1302 577 3.30 / 169.29 2 4
5 8 0.24 175 15.36 412 1107 4.41 / 170.40 2 10
6 14 0.24 20 15.33 403 124 4.53 / 170.53 2 14
Average= 4.26
(KJ/cycle)

Cycle 38 GMT 19/12/2019 10:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.36 28 15.28 671 287 0.29 / 161.68 2 2
2 7 2003.76 30 15.20 2983 1360 1.65 / 163.04 2 2
3 13 1577.36 29 15.17 2470 1087 2.73 / 164.12 2 2
4 13 643.28 29 15.28 1310 580 3.31 / 164.71 2 4
5 13 18.04 3 15.41 483 22 3.34 / 164.73 2 3
6 8 0.12 175 15.35 423 1136 4.47 / 165.86 2 16
7 14 0.12 20 15.33 425 130 4.60 / 165.99 2 14
Average= 4.26
(KJ/cycle)

Cycle 37 GMT 9/12/2019 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.16 28 15.28 662 283 0.28 / 157.27 2 3
2 7 2006.24 30 15.21 2986 1363 1.65 / 158.63 2 2
3 13 1467.36 29 15.18 2338 1029 2.67 / 159.66 2 3
4 13 700.48 29 15.27 1374 608 3.28 / 160.27 2 4
5 8 0.28 175 15.36 418 1124 4.41 / 161.39 2 14
Average= 4.25
(KJ/cycle)

Cycle 36 GMT 29/11/2019 14:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.80 28 15.27 670 286 0.29 / 152.86 2 3
2 7 2007.68 30 15.21 2985 1362 1.65 / 154.22 2 2
3 13 1594.36 29 15.17 2472 1088 2.74 / 155.31 2 2
4 13 650.04 29 15.29 1279 567 3.30 / 155.88 2 4
5 8 -0.04 175 15.36 412 1107 4.41 / 156.98 2 12
Average= 4.24
(KJ/cycle)

Cycle 35 GMT 19/11/2019 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.76 28 15.28 679 291 0.29 / 148.20 2 2
2 7 2002.28 30 15.21 2986 1363 1.65 / 149.56 2 2
3 13 1590.68 29 15.17 2489 1095 2.75 / 150.66 2 2
4 13 647.20 29 15.29 1303 578 3.33 / 151.23 2 3
5 13 15.56 29 15.40 461 206 3.53 / 151.44 2 5
6 8 0.12 175 15.35 422 1134 4.67 / 152.57 2 15
Average= 4.24
(KJ/cycle)

Cycle 34 GMT 9/11/2019 18:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.44 28 15.28 653 279 0.28 / 143.71 2 2
2 7 2003.16 30 15.21 2991 1365 1.64 / 145.08 2 2
3 13 1588.04 29 15.17 2485 1093 2.74 / 146.17 2 2
4 13 646.52 29 15.29 1303 578 3.32 / 146.75 2 3
5 8 0.12 175 15.36 431 1159 4.47 / 147.91 2 12
Average= 4.23
(KJ/cycle)

Cycle 33 GMT 30/10/2019 20:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.64 28 15.29 684 293 0.29 / 139.28 2 3
2 7 2006.08 30 15.22 2992 1366 1.66 / 140.64 2 2
3 13 1471.04 29 15.19 2343 1032 2.69 / 141.67 2 3
4 13 700.16 29 15.28 1370 607 3.30 / 142.28 2 4
5 8 0.00 175 15.36 429 1153 4.45 / 143.43 2 13
Average= 4.22
(KJ/cycle)

Cycle 32 GMT 20/10/2019 22:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.88 28 15.29 669 286 0.29 / 134.79 2 2
2 7 2003.04 30 15.22 2985 1363 1.65 / 136.16 2 2
3 13 1585.52 29 15.18 2486 1094 2.74 / 137.25 2 2
4 13 649.12 29 15.30 1308 580 3.32 / 137.83 2 3
5 8 0.28 175 15.37 428 1151 4.48 / 138.98 2 19
Average= 4.21
(KJ/cycle)

Cycle 31 GMT 11/10/2019 0:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.84 28 15.29 685 293 0.29 / 130.19 2 2
2 7 2003.32 30 15.23 2996 1369 1.66 / 131.56 2 2
3 13 1586.76 29 15.18 2490 1096 2.76 / 132.65 2 2
4 13 786.20 29 15.27 1485 658 3.42 / 133.31 2 3
5 13 18.12 7 15.42 485 52 3.47 / 133.36 2 4
6 8 1.16 175 15.37 425 1143 4.61 / 134.51 2 11
Average= 4.20
(KJ/cycle)

Cycle 30 GMT 1/10/2019 2:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.44 28 15.28 681 291 0.29 / 125.61 2 2
2 7 2008.04 30 15.22 2998 1369 1.66 / 126.98 2 2
3 13 1593.64 29 15.18 2493 1097 2.76 / 128.08 2 2
4 13 777.20 29 15.28 1467 650 3.41 / 128.73 2 3
5 8 0.16 175 15.37 435 1170 4.58 / 129.90 2 12
Average= 4.19
(KJ/cycle)

Cycle 29 GMT 21/ 9/2019 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.76 28 15.30 679 291 0.29 / 120.83 2 3
2 7 2005.24 30 15.23 3003 1372 1.66 / 122.20 2 2
3 13 1603.00 29 15.19 2497 1100 2.76 / 123.30 2 2
4 13 801.16 29 15.27 1493 661 3.42 / 123.97 2 3
5 13 48.24 5 15.42 526 41 3.46 / 124.01 2 4
6 8 0.28 175 15.37 438 1178 4.64 / 125.18 2 11
7 14 0.28 20 15.34 437 134 4.78 / 125.32 2 13
Average= 4.18
(KJ/cycle)

Cycle 28 GMT 11/ 9/2019 6:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.68 28 15.29 680 291 0.29 / 116.40 2 3
2 7 2001.56 30 15.22 2981 1361 1.65 / 117.76 2 2
3 13 1577.04 29 15.19 2465 1086 2.74 / 118.84 2 2
4 13 620.08 29 15.31 1270 564 3.30 / 119.41 2 3
5 8 0.28 175 15.38 421 1133 4.44 / 120.54 2 17
Average= 4.16
(KJ/cycle)

Cycle 27 GMT 1/ 9/2019 8:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.64 28 15.30 681 292 0.29 / 111.89 2 2
2 7 2003.28 31 15.22 2990 1411 1.70 / 113.30 2 2
3 13 1468.00 29 15.21 2337 1031 2.73 / 114.33 2 3
4 13 693.44 29 15.30 1370 608 3.34 / 114.94 2 3
5 8 -0.36 175 15.38 433 1165 4.51 / 116.11 2 12
Average= 4.15
(KJ/cycle)

Cycle 26 GMT 22/ 8/2019 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.28 28 15.30 680 291 0.29 / 107.47 2 2
2 7 2002.12 30 15.23 2977 1360 1.65 / 108.83 2 2
3 13 1454.00 29 15.21 2326 1026 2.68 / 109.86 2 3
4 13 682.36 29 15.30 1358 603 3.28 / 110.46 2 3
5 8 0.36 175 15.38 423 1139 4.42 / 111.60 2 13
Average= 4.13
(KJ/cycle)

Cycle 25 GMT 12/ 8/2019 12: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.92 28 15.31 680 292 0.29 / 102.96 2 3
2 7 2003.56 30 15.23 2977 1360 1.65 / 104.32 2 2
3 13 1575.92 29 15.20 2470 1089 2.74 / 105.41 2 2
4 13 630.96 29 15.32 1277 567 3.31 / 105.98 2 4
5 13 64.76 6 15.43 539 50 3.36 / 106.03 2 4
6 8 -0.08 175 15.38 428 1152 4.51 / 107.18 2 12
Average= 4.12
(KJ/cycle)

Cycle 24 GMT 2/ 8/2019 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.20 28 15.31 689 295 0.30 / 98.50 2 3
2 7 2007.00 30 15.24 2989 1367 1.66 / 99.87 2 2
3 13 1592.00 29 15.20 2497 1101 2.76 / 100.97 2 2
4 13 649.12 29 15.32 1310 582 3.34 / 101.55 2 3
5 8 -0.44 175 15.39 417 1123 4.47 / 102.67 2 10
Average= 4.11
(KJ/cycle)

Cycle 23 GMT 23/ 7/2019 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.00 28 15.31 670 287 0.29 / 94.00 2 3
2 7 2003.36 30 15.23 2995 1368 1.66 / 95.36 2 2
3 13 1577.96 29 15.21 2472 1090 2.75 / 96.45 2 2
4 13 641.48 29 15.32 1302 578 3.32 / 97.03 2 3
5 8 0.28 175 15.39 435 1172 4.50 / 98.20 2 14
Average= 4.09
(KJ/cycle)

Cycle 22 GMT 13/ 7/2019 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.44 28 15.32 687 295 0.29 / 89.48 2 3
2 7 2003.12 30 15.24 2988 1366 1.66 / 90.85 2 2
3 13 1581.64 29 15.21 2483 1095 2.76 / 91.94 2 2
4 13 658.88 29 15.32 1330 591 3.35 / 92.53 2 3
5 8 0.36 175 15.39 437 1177 4.52 / 93.71 2 14
Average= 4.07
(KJ/cycle)

Cycle 21 GMT 3/ 7/2019 19:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.08 28 15.32 665 285 0.29 / 85.28 2 2
2 7 2002.28 30 15.25 2981 1364 1.65 / 86.64 2 2
3 13 1591.32 18 15.24 2504 687 2.34 / 87.33 2 2
4 13 900.88 18 15.30 1652 455 2.79 / 87.78 2 3
5 13 481.56 18 15.36 1109 307 3.10 / 88.09 2 3
6 8 0.52 165 15.40 431 1095 4.19 / 89.18 2 13
Average= 4.05
(KJ/cycle)

Cycle 20 GMT 23/ 6/2019 21: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.84 27 15.33 660 273 0.27 / 80.72 2 2
2 7 2001.84 30 15.25 3001 1373 1.65 / 82.09 2 2
3 13 1582.72 18 15.25 2501 687 2.33 / 82.78 2 2
4 13 1134.36 18 15.28 1944 535 2.87 / 83.31 2 3
5 13 515.68 18 15.36 1153 319 3.19 / 83.63 2 4
6 13 94.64 6 15.44 590 55 3.24 / 83.69 2 4
7 8 -0.52 165 15.40 435 1105 4.35 / 84.79 2 9
8 14 -0.52 30 15.37 434 200 4.55 / 84.99 2 10
Average= 4.05
(KJ/cycle)

Cycle 19 GMT 13/ 6/2019 22:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.00 27 15.32 661 273 0.27 / 76.57 2 2
2 3 1016.28 1 15.43 1859 29 0.30 / 76.60 2 2
3 7 2002.64 30 15.25 2977 1362 1.66 / 77.96 2 2
4 13 1461.56 18 15.26 2346 644 2.31 / 78.60 2 2
5 13 895.56 18 15.32 1634 451 2.76 / 79.05 2 3
6 13 462.20 18 15.37 1082 299 3.06 / 79.35 2 4
7 8 0.44 165 15.41 430 1093 4.15 / 80.45 2 15
Average= 4.02
(KJ/cycle)

Cycle 18 GMT 4/ 6/2019 0:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.92 27 15.33 658 272 0.27 / 72.44 2 2
2 7 2001.36 30 15.26 2983 1366 1.64 / 73.81 2 2
3 13 1460.72 18 15.27 2347 645 2.28 / 74.45 2 2
4 13 925.00 18 15.31 1674 461 2.74 / 74.92 2 3
5 13 383.72 15 15.39 977 226 2.97 / 75.14 2 3
6 13 64.44 6 15.45 557 52 3.02 / 75.19 2 4
7 8 0.08 165 15.41 433 1101 4.12 / 76.29 2 12
Average= 4.02
(KJ/cycle)

Cycle 17 GMT 25/ 5/2019 1:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.24 27 15.34 661 274 0.27 / 68.28 2 2
2 7 2002.40 30 15.25 2988 1367 1.64 / 69.65 2 2
3 13 1454.12 18 15.28 2325 639 2.28 / 70.29 2 2
4 13 1030.80 18 15.30 1805 497 2.78 / 70.79 2 3
5 13 430.16 18 15.38 1035 287 3.06 / 71.07 2 3
6 8 0.36 165 15.41 432 1098 4.16 / 72.17 2 15
Average= 4.01
(KJ/cycle)

Cycle 16 GMT 15/ 5/2019 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.16 27 15.32 645 267 0.27 / 64.09 2 2
2 7 2003.40 30 15.25 2986 1366 1.63 / 65.45 2 2
3 13 1580.44 18 15.26 2501 687 2.32 / 66.14 2 2
4 13 980.28 18 15.31 1739 479 2.80 / 66.62 2 3
5 13 399.08 15 15.39 1010 233 3.03 / 66.85 2 4
6 13 66.24 6 15.45 561 52 3.08 / 66.90 2 4
7 8 0.00 165 15.41 435 1106 4.19 / 68.01 2 12
Average= 4.00
(KJ/cycle)

Cycle 15 GMT 5/ 5/2019 5: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.88 27 15.33 675 279 0.28 / 59.45 2 2
2 7 2002.12 30 15.26 2995 1371 1.65 / 60.82 2 2
3 13 1574.24 18 15.27 2491 685 2.34 / 61.51 2 2
4 13 976.20 18 15.32 1735 478 2.81 / 61.99 2 3
5 13 407.52 18 15.39 1003 278 3.09 / 62.27 2 4
6 13 66.24 18 15.44 540 150 3.24 / 62.42 2 4
7 13 19.40 18 15.45 478 133 3.37 / 62.55 2 5
8 8 0.24 165 15.40 424 1077 4.45 / 63.63 2 17
9 14 0.24 30 15.37 418 193 4.64 / 63.82 2 14
Average= 3.99
(KJ/cycle)

Cycle 14 GMT 25/ 4/2019 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 151.36 27 15.34 654 271 0.27 / 54.89 2 2
2 7 2005.20 30 15.27 2995 1372 1.64 / 56.26 2 2
3 13 1588.68 18 15.27 2507 689 2.33 / 56.95 2 2
4 13 1005.92 18 15.31 1789 493 2.82 / 57.44 2 3
5 13 428.36 18 15.39 1033 286 3.11 / 57.73 2 3
6 13 61.40 18 15.45 532 148 3.26 / 57.88 2 4
7 8 0.00 165 15.41 433 1101 4.36 / 58.98 2 11
8 14 0.00 30 15.38 427 197 4.56 / 59.17 2 15
Average= 3.94
(KJ/cycle)

Cycle 13 GMT 15/ 4/2019 8: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 155.40 27 15.34 657 272 0.27 / 50.57 2 2
2 7 2001.76 30 15.28 2982 1367 1.64 / 51.94 2 2
3 13 1575.28 18 15.27 2485 683 2.32 / 52.62 2 2
4 13 987.32 18 15.33 1744 481 2.80 / 53.10 2 3
5 13 410.64 18 15.40 1010 280 3.08 / 53.38 2 3
6 13 27.44 18 15.46 486 135 3.22 / 53.52 2 4
7 8 0.12 165 15.42 431 1097 4.32 / 54.62 2 9
Average= 3.90
(KJ/cycle)

Cycle 12 GMT 5/ 4/2019 9:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.16 27 15.35 682 283 0.28 / 46.25 2 2
2 7 2003.52 30 15.26 2986 1367 1.65 / 47.62 2 2
3 13 1573.72 18 15.28 2483 683 2.33 / 48.30 2 2
4 13 982.12 18 15.33 1728 477 2.81 / 48.78 2 3
5 13 408.44 18 15.40 1007 279 3.09 / 49.06 2 3
6 13 26.52 18 15.46 488 136 3.22 / 49.19 2 4
7 8 0.48 165 15.42 436 1109 4.33 / 50.30 2 10
Average= 3.87
(KJ/cycle)

Cycle 11 GMT 26/ 3/2019 11: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 169.08 27 15.36 673 279 0.28 / 41.96 2 2
2 7 2001.32 30 15.28 2989 1370 1.65 / 43.33 2 2
3 13 1575.84 18 15.29 2501 688 2.34 / 44.02 2 2
4 13 994.52 18 15.33 1760 486 2.82 / 44.51 2 3
5 13 420.28 18 15.40 1028 285 3.11 / 44.79 2 3
6 13 64.88 6 15.47 555 52 3.16 / 44.85 2 4
7 8 -0.04 165 15.43 441 1123 4.28 / 45.97 2 12
Average= 3.83
(KJ/cycle)

Cycle 10 GMT 16/ 3/2019 12:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.56 27 15.36 671 278 0.28 / 37.68 2 2
2 3 1015.52 1 15.45 1867 29 0.31 / 37.71 2 2
3 7 2003.04 30 15.28 2991 1371 1.68 / 39.08 2 2
4 13 1582.56 17 15.28 2498 649 2.33 / 39.73 2 2
5 13 1000.08 17 15.33 1750 456 2.78 / 40.19 2 3
6 13 450.28 17 15.40 1044 273 3.06 / 40.46 2 3
7 13 80.36 6 15.47 560 52 3.11 / 40.51 2 4
8 13 18.32 13 15.47 469 94 3.20 / 40.61 2 4
9 8 0.32 165 15.43 423 1077 4.28 / 41.69 2 17
Average= 3.79
(KJ/cycle)

Cycle 9 GMT 6/ 3/2019 14: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.00 27 15.36 679 282 0.28 / 33.45 2 2
2 7 2001.72 30 15.28 2984 1368 1.65 / 34.82 2 2
3 13 1576.60 17 15.29 2489 647 2.30 / 35.46 2 2
4 13 995.52 17 15.33 1757 458 2.75 / 35.92 2 3
5 13 437.84 17 15.41 1026 269 3.02 / 36.19 2 3
6 13 34.84 17 15.47 484 127 3.15 / 36.32 2 4
7 8 0.00 165 15.43 427 1087 4.24 / 37.41 2 13
Average= 3.74
(KJ/cycle)

Cycle 8 GMT 24/ 2/2019 15:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.76 27 15.36 649 269 0.27 / 29.17 2 2
2 7 2001.44 31 15.28 2982 1413 1.68 / 30.59 2 2
3 13 1438.88 17 15.31 2297 598 2.28 / 31.18 2 2
4 13 1017.24 17 15.33 1788 466 2.75 / 31.65 2 3
5 13 446.16 17 15.40 1070 280 3.03 / 31.93 2 3
6 13 34.52 17 15.47 504 133 3.16 / 32.06 2 4
7 8 0.04 165 15.43 434 1105 4.26 / 33.17 2 15
Average= 3.69
(KJ/cycle)

Cycle 7 GMT 14/ 2/2019 16:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.36 27 15.39 645 268 0.27 / 24.98 2 2
2 7 2003.72 30 15.29 2971 1363 1.63 / 26.34 2 2
3 13 1561.60 17 15.30 2447 636 2.27 / 26.98 2 2
4 13 987.48 17 15.34 1738 453 2.72 / 27.43 2 3
5 13 424.64 17 15.42 1010 265 2.99 / 27.70 2 3
6 13 16.48 17 15.48 473 124 3.11 / 27.82 2 4
7 8 0.28 165 15.43 425 1082 4.19 / 28.91 2 12
Average= 3.61
(KJ/cycle)

Cycle 6 GMT 4/ 2/2019 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.60 27 15.38 646 268 0.27 / 20.92 2 2
2 3 1030.32 1 15.45 1876 29 0.30 / 20.94 2 2
3 7 2002.04 38 15.25 2945 1707 2.00 / 22.65 2 2
4 13 1266.48 17 15.33 2074 541 2.54 / 23.19 2 2
5 13 712.68 17 15.38 1363 356 2.90 / 23.55 2 3
6 13 283.84 12 15.45 816 151 3.05 / 23.70 2 3
7 8 0.08 165 15.45 398 1015 4.07 / 24.71 2 9
Average= 3.53
(KJ/cycle)

Cycle 5 GMT 25/ 1/2019 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.64 29 15.37 640 285 0.29 / 16.85 2 2
2 3 891.08 -4 15.71 8 0 0.00 / 16.85 2 2
3 7 2002.32 38 15.26 2941 1705 1.99 / 18.56 2 2
4 13 1250.68 17 15.34 2046 534 2.52 / 19.09 2 2
5 13 687.96 17 15.39 1331 348 2.87 / 19.44 2 3
6 13 259.56 11 15.46 767 130 3.00 / 19.57 2 3
7 13 66.28 6 15.49 518 48 3.05 / 19.62 2 4
8 8 0.20 165 15.45 403 1027 4.08 / 20.65 2 8
Average= 3.44
(KJ/cycle)

Cycle 4 GMT 15/ 1/2019 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 168.60 25 15.38 638 245 0.25 / 13.25 2 2
2 3 1020.12 1 15.45 1829 28 0.27 / 13.28 2 2
3 7 1525.64 38 15.31 2362 1374 1.65 / 14.65 2 2
4 13 1117.04 17 15.34 1877 489 2.14 / 15.14 2 2
5 13 556.76 17 15.40 1169 306 2.44 / 15.45 2 3
6 13 134.56 8 15.46 632 78 2.52 / 15.52 2 3
7 8 0.12 165 15.44 410 1045 3.57 / 16.57 2 12
Average= 3.31
(KJ/cycle)

Cycle 3 GMT 14/ 1/2019 21:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 166.28 23 15.41 636 225 0.23 / 9.18 2 2
2 10 1040.36 3 15.36 1858 86 0.31 / 9.27 2 2
3 7 1521.92 74 15.24 2335 2633 2.94 / 11.90 2 2
4 13 124.04 7 15.48 601 65 3.01 / 11.96 2 3
5 13 50.92 5 15.49 501 39 3.05 / 12.00 2 3
6 8 0.32 165 15.45 392 999 4.05 / 13.00 2 12
Average= 3.25
(KJ/cycle)

Cycle 2 GMT 13/ 1/2019 23:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.48 32 15.45 631 312 0.31 / 5.28 2 3
2 3 802.68 -4 15.75 7 0 0.00 / 5.28 2 3
3 3 899.88 -2 15.77 7 0 0.00 / 5.28 2 3
4 7 1514.32 74 15.25 2315 2612 2.92 / 7.89 2 2
5 13 118.68 7 15.49 587 64 2.99 / 7.96 2 3
6 8 -0.04 165 15.47 391 998 3.99 / 8.95 2 9
Average= 2.98
(KJ/cycle)

Cycle 1 GMT 13/ 1/2019 1:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 27 15.64 485 205 0.20 / 2.10 2 2
2 3 923.08 -1 15.79 8 0 0.00 / 2.10 2 2
3 3 945.60 -1 15.80 8 0 0.00 / 2.10 2 2
4 7 976.20 74 15.40 1655 1886 2.09 / 3.98 2 3
5 8 0.00 165 15.53 385 987 3.08 / 4.97 2 11
Average= 2.48
(KJ/cycle)

Cycle 0 GMT 12/ 1/2019 14:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 85.16 27 15.79 447 191 0.19 / 0.19 2 2
2 7 99.40 75 15.76 450 532 0.72 / 0.72 2 2
3 8 0.28 240 15.71 310 1169 1.89 / 1.89 2 13
Average= 1.89
(KJ/cycle)