Cycle 222 GMT 15/12/2024 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 26 15.04 506 198 0.20 / 899.80 2 2
2 3 987.12 -1 15.48 7 0 0.00 / 899.80 2 2
3 7 2006.52 32 14.97 2901 1390 1.59 / 901.19 2 3
4 13 1600.20 17 14.97 2434 619 2.21 / 901.81 2 3
5 13 1037.68 17 14.99 1740 443 2.65 / 902.25 2 4
6 13 606.72 17 15.03 1182 302 2.95 / 902.55 2 5
7 13 171.36 9 15.11 617 84 3.04 / 902.63 2 5
8 8 0.00 175 15.10 362 957 3.99 / 903.59 2 15
Average= 4.05
(KJ/cycle)

Cycle 221 GMT 5/12/2024 21:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 26 15.04 517 202 0.20 / 895.71 2 2
2 7 2002.72 32 14.98 2903 1392 1.59 / 897.10 2 3
3 13 1599.60 17 14.97 2438 620 2.21 / 897.72 2 3
4 13 1053.20 17 14.99 1762 449 2.66 / 898.17 2 4
5 13 631.92 17 15.02 1221 312 2.97 / 898.48 2 5
6 13 99.84 7 15.13 528 56 3.03 / 898.54 2 6
7 13 15.80 17 15.14 405 104 3.14 / 898.64 2 6
8 8 0.12 175 15.09 363 959 4.09 / 899.60 2 18
Average= 4.05
(KJ/cycle)

Cycle 220 GMT 26/11/2024 0: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 26 15.04 519 203 0.20 / 891.56 2 2
2 7 2006.80 32 14.98 2902 1391 1.59 / 892.95 2 2
3 13 1607.84 17 14.98 2445 623 2.22 / 893.58 2 3
4 13 1051.72 17 14.99 1754 447 2.66 / 894.02 2 4
5 13 627.24 17 15.02 1222 312 2.98 / 894.34 2 5
6 13 188.84 9 15.11 650 88 3.06 / 894.42 2 5
7 8 0.20 175 15.10 367 970 4.03 / 895.39 2 17
8 14 0.20 20 15.07 368 111 4.14 / 895.50 3 15
Average= 4.05
(KJ/cycle)

Cycle 219 GMT 16/11/2024 1:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 26 15.04 517 202 0.20 / 887.50 2 2
2 7 2004.76 32 14.97 2895 1387 1.59 / 888.89 2 2
3 13 1617.76 17 14.97 2457 625 2.21 / 889.52 2 3
4 13 1187.52 17 14.98 1915 488 2.70 / 890.00 2 4
5 13 610.16 17 15.03 1197 306 3.01 / 890.31 2 4
6 13 184.48 9 15.11 641 87 3.09 / 890.40 2 5
7 8 0.12 175 15.10 364 962 4.06 / 891.36 2 12
Average= 4.05
(KJ/cycle)

Cycle 218 GMT 6/11/2024 4: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 26 15.05 510 200 0.20 / 883.49 2 2
2 7 2012.56 32 14.97 2911 1394 1.59 / 884.89 2 2
3 13 1601.28 17 14.97 2433 619 2.21 / 885.51 2 4
4 13 1185.20 17 14.98 1918 488 2.70 / 885.99 2 4
5 13 604.88 17 15.03 1184 303 3.00 / 886.30 2 5
6 13 96.12 7 15.13 521 55 3.06 / 886.35 2 5
7 8 0.32 175 15.10 360 951 4.01 / 887.30 2 15
Average= 4.05
(KJ/cycle)

Cycle 217 GMT 27/10/2024 6:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 25 15.05 519 195 0.20 / 879.43 2 2
2 3 1016.76 1 15.16 1780 27 0.22 / 879.46 2 2
3 7 2008.12 32 14.97 2901 1390 1.61 / 880.85 2 2
4 13 1598.40 17 14.98 2427 618 2.23 / 881.47 2 3
5 13 1169.96 17 14.99 1905 485 2.72 / 881.95 2 4
6 13 599.40 17 15.03 1178 301 3.02 / 882.25 2 4
7 13 174.32 9 15.12 620 84 3.10 / 882.34 2 6
8 8 -0.04 175 15.10 361 954 4.05 / 883.29 2 13
Average= 4.05
(KJ/cycle)

Cycle 216 GMT 17/10/2024 8:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 26 15.05 518 203 0.20 / 875.46 2 3
2 3 982.48 -1 15.45 6 0 0.00 / 875.46 2 3
3 7 2010.96 32 14.98 2901 1391 1.59 / 876.85 2 2
4 13 1604.56 17 14.98 2430 619 2.21 / 877.47 2 3
5 13 1048.48 17 15.00 1745 445 2.66 / 877.91 2 4
6 13 523.04 17 15.05 1070 274 2.93 / 878.19 2 5
7 13 127.68 7 15.13 559 59 2.99 / 878.25 2 5
8 13 73.76 6 15.14 485 44 3.03 / 878.29 2 6
9 8 0.32 175 15.10 358 946 3.98 / 879.24 2 17
Average= 4.05
(KJ/cycle)

Cycle 215 GMT 7/10/2024 10: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 26 15.04 522 204 0.20 / 871.31 2 2
2 7 2009.20 32 14.97 2904 1391 1.60 / 872.70 2 2
3 13 1591.72 17 14.98 2433 620 2.21 / 873.32 2 3
4 13 1169.20 17 14.98 1893 482 2.70 / 873.81 2 4
5 13 589.48 17 15.03 1164 297 2.99 / 874.10 2 5
6 13 167.88 9 15.12 617 84 3.08 / 874.19 2 6
7 8 0.24 175 15.11 363 960 4.04 / 875.15 2 10
8 14 0.24 20 15.08 364 110 4.15 / 875.26 2 16
Average= 4.05
(KJ/cycle)

Cycle 214 GMT 27/ 9/2024 12: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 26 15.05 530 207 0.21 / 867.16 2 2
2 3 1017.32 1 15.16 1787 27 0.23 / 867.19 2 2
3 7 2009.20 32 14.98 2907 1393 1.63 / 868.58 2 2
4 13 1613.68 17 14.98 2448 623 2.25 / 869.20 2 3
5 13 1183.16 17 14.98 1917 488 2.74 / 869.69 2 4
6 13 620.84 17 15.03 1203 307 3.05 / 870.00 2 5
7 13 191.84 9 15.12 644 88 3.13 / 870.09 2 6
8 13 48.12 5 15.15 454 34 3.17 / 870.12 2 6
9 13 44.32 5 15.15 441 33 3.20 / 870.16 2 6
10 8 0.20 175 15.10 361 954 4.16 / 871.11 2 17
Average= 4.05
(KJ/cycle)

Cycle 213 GMT 17/ 9/2024 14: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 25 15.05 517 195 0.19 / 863.03 2 2
2 3 1030.76 1 15.15 1809 27 0.22 / 863.06 2 2
3 7 2004.28 32 14.97 2902 1390 1.61 / 864.45 2 3
4 13 1608.72 17 14.97 2443 622 2.23 / 865.07 2 3
5 13 1059.52 17 14.99 1757 448 2.68 / 865.52 2 4
6 13 634.36 17 15.02 1220 312 2.99 / 865.83 2 4
7 13 100.68 7 15.13 527 56 3.05 / 865.89 2 6
8 8 0.20 175 15.11 361 955 4.00 / 866.84 2 16
9 14 0.20 20 15.08 363 109 4.11 / 866.95 2 15
Average= 4.05
(KJ/cycle)

Cycle 212 GMT 7/ 9/2024 16: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 25 15.05 516 194 0.19 / 859.03 2 2
2 7 2011.40 32 14.97 2915 1396 1.59 / 860.42 2 3
3 13 1599.16 17 14.98 2438 621 2.21 / 861.05 2 3
4 13 1030.08 17 15.00 1728 441 2.65 / 861.49 2 4
5 13 609.32 17 15.03 1197 306 2.96 / 861.79 2 5
6 13 175.04 9 15.12 627 85 3.04 / 861.88 2 6
7 8 0.08 175 15.11 364 963 4.01 / 862.84 2 20
Average= 4.05
(KJ/cycle)

Cycle 211 GMT 28/ 8/2024 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 25 15.04 542 204 0.20 / 854.85 2 2
2 3 986.52 -1 15.48 6 0 0.00 / 854.85 2 2
3 7 2010.68 32 14.97 2913 1395 1.60 / 856.25 2 2
4 13 1593.64 17 14.98 2420 616 2.22 / 856.87 2 3
5 13 1159.48 17 14.99 1891 482 2.70 / 857.35 2 4
6 13 580.92 17 15.04 1158 296 2.99 / 857.64 2 5
7 13 89.40 6 15.15 516 47 3.04 / 857.69 2 6
8 13 65.08 6 15.15 476 43 3.08 / 857.73 2 7
9 13 44.12 5 15.15 444 34 3.12 / 857.77 2 6
10 8 0.00 175 15.11 362 957 4.07 / 858.72 2 14
11 14 0.00 20 15.08 365 110 4.18 / 858.83 2 17
Average= 4.05
(KJ/cycle)

Cycle 210 GMT 18/ 8/2024 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 25 15.07 518 195 0.20 / 850.68 2 2
2 7 2009.32 32 14.98 2905 1393 1.59 / 852.07 2 2
3 13 1614.04 17 14.97 2445 622 2.21 / 852.70 2 4
4 13 1064.40 17 14.99 1764 450 2.66 / 853.14 2 4
5 13 638.32 17 15.03 1229 314 2.97 / 853.46 2 4
6 13 205.80 10 15.12 666 101 3.07 / 853.56 2 6
7 8 0.68 175 15.10 370 978 4.05 / 854.54 2 13
8 14 0.68 20 15.08 372 112 4.16 / 854.65 2 18
Average= 4.05
(KJ/cycle)

Cycle 209 GMT 8/ 8/2024 22: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 26 15.04 526 206 0.21 / 846.75 2 2
2 3 984.12 -1 15.45 6 0 0.00 / 846.75 2 2
3 7 2011.04 32 14.97 2900 1389 1.59 / 848.14 2 3
4 13 1605.00 17 14.98 2431 619 2.21 / 848.76 2 5
5 13 1041.28 17 15.01 1735 443 2.66 / 849.20 2 4
6 13 497.92 17 15.07 1043 267 2.92 / 849.47 2 5
7 13 104.40 7 15.15 538 57 2.98 / 849.52 2 5
8 8 -0.04 175 15.12 363 960 3.94 / 850.49 2 12
Average= 4.05
(KJ/cycle)

Cycle 208 GMT 29/ 7/2024 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 25 15.05 531 200 0.20 / 842.58 2 2
2 3 1035.16 1 15.14 1817 28 0.23 / 842.60 2 2
3 7 2006.72 32 14.98 2904 1392 1.62 / 844.00 2 2
4 13 1596.36 17 14.99 2429 619 2.24 / 844.61 2 3
5 13 1168.20 17 14.99 1898 484 2.72 / 845.10 2 4
6 13 590.96 17 15.05 1166 298 3.02 / 845.40 2 5
7 13 164.44 9 15.13 602 82 3.10 / 845.48 2 5
8 13 17.12 17 15.15 402 104 3.21 / 845.58 2 8
9 8 0.40 175 15.10 364 962 4.17 / 846.54 2 14
Average= 4.05
(KJ/cycle)

Cycle 207 GMT 20/ 7/2024 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 25 15.06 540 203 0.20 / 838.54 2 2
2 7 2011.92 32 14.97 2917 1397 1.60 / 839.94 2 3
3 13 1604.28 17 14.98 2439 621 2.22 / 840.56 2 4
4 13 1054.08 17 15.00 1762 449 2.67 / 841.01 2 4
5 13 618.16 17 15.03 1205 308 2.98 / 841.32 2 5
6 13 95.32 7 15.14 517 55 3.03 / 841.37 2 6
7 13 46.12 5 15.16 464 35 3.07 / 841.41 2 6
8 8 -0.32 175 15.11 366 968 4.04 / 842.38 2 15
Average= 4.05
(KJ/cycle)

Cycle 206 GMT 10/ 7/2024 3:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 25 15.05 542 204 0.20 / 834.34 2 2
2 7 2006.92 32 14.98 2913 1396 1.60 / 835.73 2 2
3 13 1603.56 17 14.99 2450 624 2.22 / 836.36 2 3
4 13 1180.44 17 14.99 1922 490 2.71 / 836.85 2 4
5 13 611.16 17 15.04 1202 307 3.02 / 837.16 2 5
6 13 186.36 9 15.12 646 88 3.11 / 837.24 2 6
7 8 0.28 175 15.11 372 984 4.09 / 838.23 2 15
8 14 0.28 20 15.08 372 112 4.21 / 838.34 2 19
Average= 4.05
(KJ/cycle)

Cycle 205 GMT 30/ 6/2024 5:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 25 15.05 527 198 0.20 / 830.23 2 2
2 7 2012.56 32 14.98 2921 1400 1.60 / 831.63 2 4
3 13 1622.60 17 14.97 2468 628 2.23 / 832.26 2 4
4 13 1192.20 17 14.98 1940 494 2.72 / 832.76 2 4
5 13 611.52 17 15.04 1202 307 3.03 / 833.06 2 5
6 13 184.40 9 15.12 644 88 3.12 / 833.15 2 6
7 8 -0.08 175 15.11 372 984 4.10 / 834.13 2 11
Average= 4.05
(KJ/cycle)

Cycle 204 GMT 20/ 6/2024 7:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 25 15.05 519 195 0.20 / 826.09 2 2
2 7 2008.68 32 14.98 2910 1395 1.59 / 827.49 2 2
3 13 1603.36 17 14.98 2434 620 2.21 / 828.11 2 3
4 13 1173.52 17 14.99 1915 488 2.70 / 828.59 2 4
5 13 591.72 17 15.05 1173 300 3.00 / 828.89 2 5
6 13 157.92 8 15.14 601 73 3.07 / 828.97 2 5
7 13 16.80 17 15.16 406 105 3.18 / 829.07 2 7
8 8 0.24 175 15.11 364 963 4.14 / 830.03 2 17
Average= 4.05
(KJ/cycle)

Cycle 203 GMT 10/ 6/2024 9:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 25 15.06 533 201 0.20 / 822.02 2 2
2 7 2010.04 32 14.98 2908 1394 1.59 / 823.42 2 2
3 13 1738.12 17 14.97 2605 663 2.26 / 824.08 2 3
4 13 1147.60 17 14.99 1882 480 2.74 / 824.56 2 4
5 13 580.32 17 15.05 1156 296 3.03 / 824.86 2 5
6 13 151.80 8 15.14 595 72 3.11 / 824.93 2 6
7 8 0.16 175 15.11 366 968 4.07 / 825.90 2 14
Average= 4.05
(KJ/cycle)

Cycle 202 GMT 31/ 5/2024 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 25 15.05 540 203 0.20 / 817.95 2 2
2 7 2013.20 32 14.98 2918 1399 1.60 / 819.35 2 3
3 13 1596.16 17 14.98 2447 623 2.23 / 819.97 2 3
4 13 1178.32 17 14.98 1916 488 2.71 / 820.46 2 5
5 13 597.28 17 15.04 1183 302 3.02 / 820.76 2 5
6 13 163.32 9 15.13 617 84 3.10 / 820.85 2 6
7 8 0.40 175 15.11 369 976 4.08 / 821.82 2 14
Average= 4.05
(KJ/cycle)

Cycle 201 GMT 21/ 5/2024 13:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 25 15.06 532 200 0.20 / 813.89 2 2
2 7 2007.68 32 14.97 2912 1395 1.60 / 815.29 2 3
3 13 1599.44 17 14.98 2440 621 2.22 / 815.91 2 4
4 13 1048.40 17 15.00 1758 448 2.66 / 816.36 2 4
5 13 498.12 17 15.06 1050 269 2.93 / 816.62 2 5
6 13 105.16 7 15.14 531 56 2.99 / 816.68 2 6
7 8 -0.28 175 15.12 362 958 3.95 / 817.64 2 15
8 14 -0.28 20 15.09 364 110 4.06 / 817.75 2 22
Average= 4.05
(KJ/cycle)

Cycle 200 GMT 11/ 5/2024 15:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 25 15.06 523 197 0.20 / 809.90 2 2
2 7 2003.12 32 14.98 2910 1395 1.59 / 811.30 2 4
3 13 1602.24 17 14.98 2453 625 2.22 / 811.92 2 4
4 13 1029.48 17 15.00 1735 442 2.66 / 812.37 2 4
5 13 599.16 17 15.04 1181 302 2.96 / 812.67 2 5
6 13 93.40 6 15.15 521 47 3.01 / 812.72 2 6
7 8 1.04 175 15.11 369 976 3.98 / 813.69 2 16
Average= 4.05
(KJ/cycle)

Cycle 199 GMT 1/ 5/2024 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 25 15.06 523 197 0.20 / 805.79 2 2
2 7 2008.00 32 14.99 2914 1398 1.59 / 807.19 2 3
3 13 1595.88 17 14.98 2439 621 2.22 / 807.81 2 4
4 13 1052.00 17 15.00 1765 450 2.67 / 808.26 2 4
5 13 625.96 17 15.04 1218 311 2.98 / 808.57 2 5
6 13 101.00 7 15.15 526 56 3.03 / 808.63 2 5
7 8 -0.04 175 15.11 365 965 4.00 / 809.60 2 21
8 14 -0.04 20 15.09 368 111 4.11 / 809.71 2 14
Average= 4.05
(KJ/cycle)

Cycle 198 GMT 21/ 4/2024 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 25 15.06 514 194 0.19 / 801.68 2 2
2 7 2006.60 32 14.98 2911 1395 1.59 / 803.08 2 3
3 13 1597.16 17 14.99 2429 619 2.21 / 803.70 2 4
4 13 1161.28 17 15.00 1895 483 2.69 / 804.18 2 4
5 13 593.44 17 15.05 1171 300 2.99 / 804.48 2 5
6 13 161.08 17 15.13 603 155 3.15 / 804.64 2 7
7 8 0.08 175 15.11 364 963 4.11 / 805.60 2 15
Average= 4.05
(KJ/cycle)

Cycle 197 GMT 11/ 4/2024 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 25 15.06 522 197 0.20 / 797.59 2 3
2 7 2008.08 32 14.98 2904 1392 1.59 / 798.98 2 4
3 13 1601.80 17 14.99 2438 621 2.21 / 799.60 2 4
4 13 1180.60 17 14.99 1928 491 2.70 / 800.09 2 4
5 13 601.12 17 15.05 1188 304 3.01 / 800.40 2 5
6 13 86.68 17 15.14 508 131 3.14 / 800.53 2 7
7 8 0.52 175 15.11 364 963 4.10 / 801.49 2 15
Average= 4.05
(KJ/cycle)

Cycle 196 GMT 1/ 4/2024 23:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 26 15.06 525 206 0.21 / 793.54 2 2
2 3 983.52 -1 15.46 7 0 0.00 / 793.54 2 2
3 7 2008.04 32 14.99 2907 1394 1.60 / 794.94 2 2
4 13 1604.16 17 14.98 2445 623 2.22 / 795.56 2 3
5 13 1059.24 17 15.00 1778 453 2.68 / 796.01 2 4
6 13 522.24 17 15.06 1080 277 2.95 / 796.29 2 5
7 13 125.12 17 15.13 555 143 3.10 / 796.43 2 6
8 8 -0.16 175 15.11 363 960 4.06 / 797.39 2 17
Average= 4.05
(KJ/cycle)

Cycle 195 GMT 23/ 3/2024 1:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 26 15.06 517 202 0.20 / 789.49 2 2
2 7 2010.40 32 14.97 2914 1396 1.60 / 790.88 2 3
3 13 1611.76 17 14.98 2445 623 2.22 / 791.50 2 4
4 13 1058.80 17 15.00 1768 451 2.67 / 791.96 2 4
5 13 513.16 17 15.06 1071 274 2.95 / 792.23 2 5
6 13 116.28 17 15.13 539 139 3.08 / 792.37 2 7
7 8 0.24 175 15.11 366 968 4.05 / 793.34 2 14
Average= 4.05
(KJ/cycle)

Cycle 194 GMT 13/ 3/2024 3:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 26 15.07 519 203 0.20 / 785.37 2 2
2 3 983.96 -1 15.46 6 0 0.00 / 785.37 2 2
3 7 2005.76 32 14.99 2904 1393 1.60 / 786.77 2 3
4 13 1729.72 17 14.98 2589 659 2.26 / 787.43 2 4
5 13 1030.00 17 15.01 1724 440 2.70 / 787.87 2 5
6 13 616.72 17 15.04 1197 306 3.00 / 788.17 2 5
7 13 182.88 17 15.12 620 159 3.16 / 788.33 2 6
8 8 -0.08 175 15.12 360 953 4.11 / 789.28 2 13
Average= 4.05
(KJ/cycle)

Cycle 193 GMT 3/ 3/2024 5:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 26 15.07 509 199 0.20 / 781.25 2 2
2 7 2009.76 32 14.99 2910 1396 1.60 / 782.65 2 3
3 13 1609.48 17 14.99 2445 623 2.22 / 783.27 2 3
4 13 1174.44 17 14.99 1904 485 2.70 / 783.76 2 4
5 13 606.68 17 15.05 1182 302 3.01 / 784.06 2 5
6 13 176.04 17 15.13 615 158 3.16 / 784.22 2 6
7 8 -0.04 175 15.12 360 953 4.12 / 785.17 2 14
Average= 4.05
(KJ/cycle)

Cycle 192 GMT 22/ 2/2024 7:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 26 15.06 512 200 0.20 / 777.12 2 2
2 3 1016.36 1 15.18 1780 27 0.23 / 777.15 2 2
3 7 2008.80 32 14.99 2905 1393 1.62 / 778.54 2 3
4 13 1608.00 17 14.99 2438 621 2.24 / 779.16 2 3
5 13 1180.52 17 15.00 1900 484 2.73 / 779.65 2 4
6 13 604.16 17 15.05 1176 301 3.03 / 779.95 2 5
7 13 175.04 17 15.13 612 157 3.19 / 780.11 2 6
8 8 0.48 175 15.12 358 947 4.13 / 781.05 2 15
Average= 4.05
(KJ/cycle)

Cycle 191 GMT 12/ 2/2024 9:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 26 15.07 518 203 0.20 / 773.05 2 2
2 7 2003.72 32 14.99 2905 1393 1.60 / 774.44 2 3
3 13 1600.60 17 14.99 2441 622 2.22 / 775.06 2 3
4 13 1058.80 17 15.01 1762 450 2.67 / 775.51 2 4
5 13 637.12 17 15.04 1228 314 2.98 / 775.82 2 4
6 13 110.60 17 15.14 537 138 3.12 / 775.96 2 6
7 8 0.00 175 15.12 362 958 4.08 / 776.92 2 19
Average= 4.05
(KJ/cycle)

Cycle 190 GMT 2/ 2/2024 11:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 26 15.07 524 205 0.21 / 769.00 2 3
2 7 2004.16 32 14.98 2902 1391 1.60 / 770.39 2 2
3 13 1595.32 17 14.98 2428 618 2.21 / 771.01 2 4
4 13 1034.56 17 15.01 1736 443 2.66 / 771.45 2 4
5 13 614.44 17 15.04 1203 308 2.97 / 771.76 2 5
6 13 91.76 17 15.15 509 131 3.10 / 771.89 2 6
7 8 0.12 175 15.12 361 955 4.05 / 772.84 2 15
Average= 4.05
(KJ/cycle)

Cycle 189 GMT 23/ 1/2024 13:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 26 15.07 532 208 0.21 / 764.92 2 2
2 7 2003.76 32 15.00 2900 1392 1.60 / 766.31 2 3
3 13 1600.64 17 14.99 2430 619 2.22 / 766.93 2 4
4 13 1050.60 17 15.02 1754 448 2.67 / 767.38 2 4
5 13 636.08 17 15.04 1230 314 2.98 / 767.70 2 4
6 13 102.84 17 15.15 523 135 3.12 / 767.83 2 7
7 8 -0.04 175 15.12 363 960 4.08 / 768.79 2 17
Average= 4.05
(KJ/cycle)

Cycle 188 GMT 13/ 1/2024 16: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 26 15.06 521 204 0.20 / 760.68 2 3
2 7 2008.68 32 14.99 2911 1396 1.60 / 762.08 2 3
3 13 1601.80 17 14.99 2435 621 2.22 / 762.70 2 3
4 13 1183.08 17 14.99 1923 490 2.71 / 763.19 2 4
5 13 594.04 17 15.05 1183 303 3.01 / 763.49 2 7
6 13 160.40 17 15.13 600 154 3.17 / 763.65 2 6
7 8 0.16 175 15.12 362 958 4.13 / 764.60 2 14
8 14 0.16 20 15.10 363 110 4.24 / 764.71 2 19
Average= 4.05
(KJ/cycle)

Cycle 187 GMT 3/ 1/2024 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 26 15.07 515 202 0.20 / 756.60 2 3
2 7 2003.56 32 14.99 2910 1396 1.60 / 758.00 2 3
3 13 1607.00 17 14.99 2450 624 2.22 / 758.62 2 3
4 13 1051.32 17 15.01 1756 448 2.67 / 759.07 2 4
5 13 624.60 17 15.05 1213 310 2.98 / 759.38 2 5
6 13 91.04 17 15.15 505 130 3.11 / 759.51 2 6
7 8 0.12 175 15.12 365 966 4.08 / 760.48 2 13
Average= 4.05
(KJ/cycle)

Cycle 186 GMT 24/12/2023 20: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 26 15.07 501 196 0.20 / 752.50 2 2
2 7 2009.72 32 14.99 2916 1399 1.60 / 753.90 2 3
3 13 1599.64 17 15.00 2440 622 2.22 / 754.52 2 4
4 13 1042.04 17 15.01 1750 447 2.66 / 754.97 2 4
5 13 619.64 17 15.05 1206 309 2.97 / 755.28 2 5
6 13 171.84 17 15.13 619 159 3.13 / 755.44 2 6
7 8 0.12 175 15.12 365 966 4.10 / 756.40 2 15
Average= 4.04
(KJ/cycle)

Cycle 185 GMT 14/12/2023 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 26 15.07 529 207 0.21 / 748.32 2 3
2 7 2011.36 32 14.99 2916 1399 1.61 / 749.72 2 3
3 13 1607.28 17 14.99 2446 623 2.23 / 750.35 2 3
4 13 1171.60 17 15.00 1910 487 2.72 / 750.83 2 4
5 13 597.68 17 15.06 1176 301 3.02 / 751.13 2 5
6 13 92.68 17 15.15 502 129 3.15 / 751.26 2 6
7 13 19.20 17 15.17 397 102 3.25 / 751.37 2 6
8 8 -0.28 175 15.12 355 939 4.19 / 752.30 2 18
Average= 4.04
(KJ/cycle)

Cycle 184 GMT 5/12/2023 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 26 15.07 511 200 0.20 / 744.19 2 3
2 3 1016.24 1 15.19 1800 27 0.23 / 744.22 2 2
3 7 2003.12 32 14.98 2908 1394 1.62 / 745.61 2 4
4 13 1606.00 17 14.99 2434 620 2.24 / 746.23 2 3
5 13 1180.00 17 15.00 1910 487 2.73 / 746.72 2 4
6 13 582.32 17 15.06 1160 297 3.03 / 747.01 2 5
7 13 141.20 17 15.15 565 146 3.17 / 747.16 2 7
8 8 0.36 175 15.13 361 956 4.13 / 748.12 2 16
Average= 4.04
(KJ/cycle)

Cycle 183 GMT 25/11/2023 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 26 15.07 516 202 0.20 / 740.08 2 2
2 7 2010.04 32 14.99 2918 1400 1.60 / 741.48 2 4
3 13 1607.04 17 14.99 2439 622 2.22 / 742.10 2 5
4 13 1187.36 17 14.99 1929 492 2.71 / 742.59 2 4
5 13 617.00 17 15.06 1203 308 3.02 / 742.90 2 5
6 13 97.68 17 15.16 514 132 3.16 / 743.03 2 6
7 8 0.28 175 15.13 362 958 4.11 / 743.99 2 14
Average= 4.04
(KJ/cycle)

Cycle 182 GMT 15/11/2023 4:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 25 15.08 517 195 0.19 / 735.97 2 2
2 7 2009.52 32 14.99 2917 1399 1.59 / 737.37 2 2
3 13 1601.20 17 14.99 2438 621 2.22 / 737.99 2 3
4 13 1054.88 17 15.01 1761 449 2.66 / 738.44 2 4
5 13 634.40 17 15.05 1228 314 2.98 / 738.75 2 5
6 13 186.12 17 15.13 634 163 3.14 / 738.91 2 6
7 8 0.28 175 15.13 363 961 4.10 / 739.88 2 17
Average= 4.04
(KJ/cycle)

Cycle 181 GMT 5/11/2023 6:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 25 15.07 532 200 0.20 / 731.94 2 3
2 7 2009.52 32 14.99 2922 1402 1.60 / 733.34 2 2
3 13 1590.92 17 15.00 2433 620 2.22 / 733.96 2 4
4 13 1046.28 17 15.02 1748 446 2.67 / 734.41 2 4
5 13 612.76 17 15.06 1201 307 2.98 / 734.71 2 4
6 13 21.16 17 15.18 405 105 3.08 / 734.82 2 6
7 8 0.04 175 15.13 360 953 4.03 / 735.77 2 13
Average= 4.04
(KJ/cycle)

Cycle 180 GMT 26/10/2023 8:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 25 15.08 530 200 0.20 / 727.73 2 3
2 7 2010.40 33 14.99 2915 1442 1.64 / 729.17 2 3
3 13 1581.92 17 14.99 2415 615 2.26 / 729.78 2 4
4 13 1031.32 17 15.02 1736 443 2.70 / 730.23 2 4
5 13 617.92 17 15.05 1203 308 3.01 / 730.53 2 5
6 13 85.72 17 15.16 496 128 3.14 / 730.66 2 6
7 8 0.00 175 15.13 364 964 4.10 / 731.63 2 13
8 14 0.00 20 15.11 370 112 4.21 / 731.74 2 16
Average= 4.04
(KJ/cycle)

Cycle 179 GMT 16/10/2023 10:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 25 15.07 530 200 0.20 / 723.60 2 2
2 7 2007.40 32 14.99 2923 1402 1.60 / 725.00 2 2
3 13 1603.60 17 15.00 2439 622 2.22 / 725.62 2 3
4 13 1176.84 17 15.00 1912 488 2.71 / 726.11 2 4
5 13 598.72 17 15.06 1181 302 3.01 / 726.41 2 5
6 13 167.32 17 15.15 606 156 3.17 / 726.57 2 6
7 8 0.24 175 15.13 362 958 4.13 / 727.53 2 13
Average= 4.04
(KJ/cycle)

Cycle 178 GMT 6/10/2023 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 26 15.08 503 197 0.20 / 719.44 2 3
2 3 984.56 -1 15.47 6 0 0.00 / 719.44 2 3
3 7 2009.76 32 14.99 2921 1401 1.60 / 720.84 2 2
4 13 1604.36 17 14.99 2442 622 2.22 / 721.46 2 3
5 13 1052.48 17 15.02 1752 447 2.67 / 721.91 2 4
6 13 630.52 17 15.05 1216 311 2.98 / 722.22 2 5
7 13 94.88 17 15.16 508 131 3.11 / 722.35 2 6
8 13 15.72 17 15.17 393 101 3.21 / 722.45 2 7
9 8 -0.32 175 15.12 357 945 4.16 / 723.40 2 14
Average= 4.04
(KJ/cycle)

Cycle 177 GMT 26/ 9/2023 14:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 26 15.08 521 204 0.20 / 715.26 2 3
2 3 981.12 -1 15.47 6 0 0.00 / 715.26 2 3
3 7 2011.20 32 14.99 2916 1399 1.60 / 716.66 2 3
4 13 1616.56 17 14.98 2459 626 2.23 / 717.29 2 3
5 13 1058.84 17 15.01 1767 451 2.68 / 717.74 2 4
6 13 642.32 17 15.05 1234 316 3.00 / 718.05 2 5
7 13 104.40 17 15.16 522 135 3.13 / 718.19 2 7
8 8 -0.12 175 15.13 358 948 4.08 / 719.13 2 16
9 14 -0.12 20 15.11 357 108 4.19 / 719.24 2 20
Average= 4.04
(KJ/cycle)

Cycle 176 GMT 16/ 9/2023 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 26 15.09 497 195 0.19 / 711.13 2 3
2 3 979.20 -1 15.47 7 0 0.00 / 711.13 2 3
3 7 2010.72 32 15.00 2918 1401 1.60 / 712.53 2 2
4 13 1602.88 17 15.00 2436 621 2.22 / 713.15 2 4
5 13 1176.12 17 15.00 1908 487 2.70 / 713.63 2 5
6 13 605.36 17 15.06 1187 304 3.01 / 713.94 2 5
7 13 167.44 17 15.14 609 157 3.16 / 714.09 2 5
8 8 0.20 175 15.13 363 961 4.13 / 715.06 2 14
Average= 4.04
(KJ/cycle)

Cycle 175 GMT 6/ 9/2023 19: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 27 15.08 506 206 0.21 / 707.05 2 2
2 3 983.44 -1 15.47 6 0 0.00 / 707.05 2 2
3 7 2007.20 32 15.00 2915 1399 1.61 / 708.45 2 4
4 13 1595.80 17 15.00 2421 617 2.22 / 709.06 2 4
5 13 1171.64 17 15.01 1906 486 2.71 / 709.55 2 4
6 13 602.32 17 15.07 1179 302 3.01 / 709.85 2 5
7 13 88.04 17 15.17 496 128 3.14 / 709.98 2 6
8 8 0.48 175 15.14 359 951 4.09 / 710.93 2 14
Average= 4.04
(KJ/cycle)

Cycle 174 GMT 27/ 8/2023 21: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 26 15.08 510 200 0.20 / 702.97 2 2
2 3 1026.84 1 15.17 1796 27 0.23 / 703.00 2 3
3 7 2003.52 32 15.00 2908 1396 1.62 / 704.39 2 4
4 13 1595.40 17 15.00 2424 618 2.24 / 705.01 2 4
5 13 1056.08 17 15.02 1760 449 2.69 / 705.46 2 4
6 13 636.88 17 15.05 1228 314 3.00 / 705.77 2 6
7 13 104.96 17 15.16 516 133 3.14 / 705.91 2 6
8 8 -0.04 175 15.14 353 935 4.07 / 706.84 2 13
Average= 4.04
(KJ/cycle)

Cycle 173 GMT 17/ 8/2023 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 27 15.08 513 209 0.21 / 698.89 2 3
2 3 983.68 -1 15.47 6 0 0.00 / 698.89 2 3
3 7 2004.88 32 15.00 2908 1396 1.60 / 700.28 2 4
4 13 1481.12 17 15.01 2276 581 2.19 / 700.86 2 4
5 13 1084.48 17 15.01 1801 460 2.65 / 701.32 2 4
6 13 660.24 17 15.05 1260 322 2.97 / 701.65 2 4
7 13 214.88 17 15.13 664 171 3.14 / 701.82 2 6
8 8 0.28 175 15.14 359 951 4.09 / 702.77 2 12
Average= 4.04
(KJ/cycle)

Cycle 172 GMT 8/ 8/2023 1: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 27 15.09 522 213 0.21 / 694.80 2 3
2 7 2002.96 33 15.00 2897 1434 1.65 / 696.23 2 3
3 13 1595.52 17 15.00 2418 617 2.26 / 696.85 2 3
4 13 1042.52 17 15.02 1748 446 2.71 / 697.29 2 4
5 13 624.84 17 15.06 1209 310 3.02 / 697.60 2 5
6 13 92.48 17 15.17 499 129 3.15 / 697.73 2 6
7 8 0.08 175 15.14 357 946 4.09 / 698.68 2 16
Average= 4.04
(KJ/cycle)

Cycle 171 GMT 29/ 7/2023 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 27 15.09 515 210 0.21 / 690.65 2 3
2 7 2012.40 32 15.00 2923 1403 1.61 / 692.05 2 3
3 13 1600.12 17 15.01 2440 623 2.24 / 692.68 2 4
4 13 1174.40 17 15.01 1917 489 2.72 / 693.17 2 4
5 13 616.72 17 15.06 1202 308 3.03 / 693.47 2 4
6 13 190.00 17 15.14 634 163 3.20 / 693.64 2 6
7 8 0.04 175 15.14 358 949 4.14 / 694.58 2 14
Average= 4.04
(KJ/cycle)

Cycle 170 GMT 19/ 7/2023 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 27 15.08 514 209 0.21 / 686.51 2 3
2 7 2008.92 32 15.00 2911 1397 1.61 / 687.91 2 3
3 13 1603.36 17 15.01 2436 622 2.23 / 688.53 2 4
4 13 1177.04 17 15.01 1924 491 2.72 / 689.02 2 4
5 13 738.84 17 15.04 1363 348 3.07 / 689.37 2 4
6 13 79.52 17 15.18 480 124 3.19 / 689.49 2 5
7 8 0.00 175 15.14 357 946 4.14 / 690.44 2 12
Average= 4.04
(KJ/cycle)

Cycle 169 GMT 9/ 7/2023 7:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 27 15.09 504 205 0.21 / 682.27 2 3
2 3 1016.32 1 15.19 1769 27 0.23 / 682.29 2 2
3 7 2003.52 32 15.01 2900 1393 1.63 / 683.69 2 4
4 13 1596.20 17 15.00 2425 618 2.24 / 684.30 2 4
5 13 1173.04 17 15.01 1906 486 2.73 / 684.79 2 4
6 13 619.36 17 15.07 1195 306 3.04 / 685.10 2 4
7 13 190.60 17 15.15 624 161 3.20 / 685.26 2 5
8 8 0.40 175 15.14 354 938 4.13 / 686.20 2 13
9 14 0.40 20 15.12 355 107 4.24 / 686.30 2 14
Average= 4.04
(KJ/cycle)

Cycle 168 GMT 29/ 6/2023 9:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 26 15.10 520 204 0.20 / 678.05 2 3
2 3 1026.08 1 15.19 1785 27 0.23 / 678.08 2 3
3 7 2011.52 33 15.00 2914 1442 1.67 / 679.52 2 3
4 13 1610.56 17 15.00 2445 623 2.30 / 680.15 2 5
5 13 1183.36 17 15.01 1908 487 2.78 / 680.63 2 3
6 13 737.96 17 15.04 1351 345 3.13 / 680.98 2 4
7 13 144.12 17 15.16 560 144 3.27 / 681.12 2 6
8 8 -0.04 175 15.14 354 938 4.21 / 682.06 2 14
Average= 4.04
(KJ/cycle)

Cycle 167 GMT 19/ 6/2023 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 26 15.10 498 196 0.20 / 673.95 2 3
2 7 2009.80 33 15.00 2912 1441 1.64 / 675.39 2 3
3 13 1598.56 17 15.00 2428 619 2.26 / 676.01 2 5
4 13 1163.76 17 15.01 1894 483 2.74 / 676.49 2 4
5 13 599.16 17 15.08 1167 299 3.04 / 676.79 2 5
6 13 81.28 17 15.18 480 124 3.16 / 676.92 2 5
7 8 0.00 175 15.15 352 933 4.10 / 677.85 2 17
Average= 4.03
(KJ/cycle)

Cycle 166 GMT 9/ 6/2023 13:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 26 15.09 510 200 0.20 / 669.86 2 3
2 3 987.12 -1 15.48 6 0 0.00 / 669.86 2 3
3 7 2006.28 33 15.00 2906 1438 1.64 / 671.29 2 2
4 13 1587.52 17 15.00 2417 616 2.25 / 671.91 2 4
5 13 1160.88 17 15.01 1885 481 2.74 / 672.39 2 5
6 13 576.16 17 15.08 1144 293 3.03 / 672.68 2 4
7 13 78.44 17 15.18 476 123 3.15 / 672.81 2 6
8 8 0.36 175 15.15 357 946 4.10 / 673.75 2 11
Average= 4.03
(KJ/cycle)

Cycle 165 GMT 30/ 5/2023 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 26 15.09 524 206 0.21 / 665.70 2 2
2 7 2010.88 33 15.00 2913 1442 1.65 / 667.14 2 3
3 13 1588.92 17 15.01 2412 615 2.26 / 667.75 2 4
4 13 1159.04 17 15.01 1890 482 2.75 / 668.24 2 4
5 13 705.00 17 15.05 1306 334 3.08 / 668.57 2 4
6 13 120.64 17 15.17 540 139 3.22 / 668.71 2 6
7 8 0.08 175 15.14 357 946 4.16 / 669.66 2 14
Average= 4.03
(KJ/cycle)

Cycle 164 GMT 20/ 5/2023 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 26 15.10 507 199 0.20 / 661.49 2 2
2 7 2009.68 33 15.01 2915 1444 1.64 / 662.94 2 3
3 13 1603.00 17 15.00 2426 619 2.26 / 663.56 2 5
4 13 1055.28 17 15.02 1751 447 2.71 / 664.00 2 4
5 13 636.16 17 15.06 1218 312 3.02 / 664.31 2 4
6 13 104.24 17 15.17 513 132 3.15 / 664.45 2 6
7 8 0.04 175 15.15 353 936 4.09 / 665.38 2 17
8 14 0.04 20 15.12 357 108 4.20 / 665.49 3 15
Average= 4.03
(KJ/cycle)

Cycle 163 GMT 10/ 5/2023 20:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 26 15.10 491 193 0.19 / 657.35 2 3
2 3 987.80 -1 15.48 6 0 0.00 / 657.35 2 3
3 7 2009.44 32 15.00 2909 1396 1.59 / 658.75 2 3
4 13 1610.44 17 15.01 2447 624 2.21 / 659.37 2 4
5 13 1177.16 17 15.01 1912 488 2.70 / 659.86 2 4
6 13 743.44 17 15.04 1362 348 3.05 / 660.21 2 4
7 13 162.12 17 15.16 587 151 3.20 / 660.36 2 6
8 8 -0.16 175 15.15 352 933 4.13 / 661.29 2 13
Average= 4.03
(KJ/cycle)

Cycle 162 GMT 30/ 4/2023 22:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 26 15.11 496 195 0.19 / 653.15 2 3
2 7 2004.80 32 15.01 2909 1397 1.59 / 654.55 2 3
3 13 1600.44 17 15.01 2425 619 2.21 / 655.17 2 3
4 13 1178.00 17 15.01 1909 487 2.70 / 655.65 2 4
5 13 619.32 17 15.07 1195 306 3.00 / 655.96 2 4
6 13 191.28 17 15.15 628 162 3.17 / 656.12 2 5
7 13 19.08 17 15.19 395 102 3.27 / 656.22 2 6
8 8 0.36 175 15.14 353 935 4.20 / 657.16 2 12
Average= 4.03
(KJ/cycle)

Cycle 161 GMT 21/ 4/2023 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 27 15.10 507 207 0.21 / 649.08 2 3
2 3 977.24 -1 15.48 7 0 0.00 / 649.08 2 3
3 7 2004.36 32 15.01 2907 1396 1.60 / 650.48 2 3
4 13 1589.00 17 15.02 2433 621 2.22 / 651.10 2 4
5 13 1167.56 17 15.02 1905 486 2.71 / 651.59 2 5
6 13 623.80 17 15.07 1205 309 3.02 / 651.90 2 5
7 13 107.16 17 15.18 512 132 3.15 / 652.03 2 5
8 8 -0.12 175 15.15 350 928 4.08 / 652.96 2 18
Average= 4.03
(KJ/cycle)

Cycle 160 GMT 11/ 4/2023 2:32:27

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 27 15.10 503 205 0.21 / 645.04 2 3
2 7 2010.88 32 15.00 2915 1399 1.60 / 646.44 2 3
3 13 1590.72 17 15.01 2422 618 2.22 / 647.05 2 4
4 13 1155.84 17 15.02 1881 480 2.70 / 647.54 2 4
5 13 594.24 17 15.08 1162 298 3.00 / 647.83 2 5
6 13 19.80 17 15.20 397 103 3.10 / 647.94 2 6
7 8 0.36 175 15.16 355 942 4.04 / 648.88 2 16
Average= 4.03
(KJ/cycle)

Cycle 159 GMT 1/ 4/2023 4:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 27 15.10 515 210 0.21 / 640.89 2 2
2 7 2011.40 32 15.01 2913 1399 1.61 / 642.29 2 3
3 13 1615.12 17 15.00 2450 625 2.23 / 642.91 2 4
4 13 1184.12 17 15.01 1922 490 2.72 / 643.40 2 4
5 13 741.16 17 15.05 1358 347 3.07 / 643.75 2 4
6 13 155.96 17 15.17 583 150 3.22 / 643.90 2 5
7 8 -0.16 175 15.15 351 931 4.15 / 644.83 2 15
Average= 4.03
(KJ/cycle)

Cycle 158 GMT 22/ 3/2023 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 27 15.11 504 206 0.21 / 636.77 2 2
2 7 2011.00 32 15.01 2915 1400 1.61 / 638.17 2 4
3 13 1607.12 17 15.02 2435 622 2.23 / 638.79 2 3
4 13 1179.04 17 15.02 1907 487 2.71 / 639.28 2 4
5 13 742.08 17 15.05 1359 348 3.06 / 639.63 2 4
6 13 81.12 17 15.19 476 123 3.19 / 639.75 2 5
7 8 0.12 175 15.16 350 929 4.11 / 640.68 2 13
Average= 4.03
(KJ/cycle)

Cycle 157 GMT 12/ 3/2023 8:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 27 15.10 517 211 0.21 / 632.66 2 3
2 7 2003.00 33 15.01 2907 1440 1.65 / 634.10 2 3
3 13 1593.08 17 15.01 2426 619 2.27 / 634.72 2 4
4 13 1173.72 17 15.02 1911 488 2.76 / 635.21 2 4
5 13 618.28 17 15.08 1198 307 3.06 / 635.51 2 4
6 13 94.88 17 15.18 499 129 3.19 / 635.64 2 6
7 8 0.28 175 15.16 348 923 4.12 / 636.57 2 16
Average= 4.03
(KJ/cycle)

Cycle 156 GMT 2/ 3/2023 10:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 26 15.11 515 202 0.20 / 628.56 2 2
2 3 1025.04 1 15.20 1772 27 0.23 / 628.58 2 2
3 7 2009.48 32 15.01 2916 1401 1.63 / 629.98 2 3
4 13 1599.36 17 15.01 2438 622 2.25 / 630.60 2 3
5 13 1172.24 17 15.01 1910 487 2.74 / 631.09 2 4
6 13 603.80 17 15.08 1179 302 3.04 / 631.39 2 6
7 13 82.52 17 15.19 480 124 3.17 / 631.52 2 6
8 8 0.32 175 15.16 351 931 4.10 / 632.45 2 13
Average= 4.03
(KJ/cycle)

Cycle 155 GMT 20/ 2/2023 12:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 26 15.10 494 194 0.19 / 624.51 2 3
2 7 2010.16 32 15.00 2917 1400 1.59 / 625.91 2 3
3 13 1597.32 17 15.01 2435 621 2.22 / 626.53 2 5
4 13 1173.56 17 15.02 1906 487 2.70 / 627.02 2 4
5 13 607.52 17 15.08 1184 304 3.01 / 627.32 2 5
6 13 44.84 17 15.20 427 110 3.12 / 627.43 2 5
7 8 0.08 175 15.16 346 918 4.03 / 628.35 2 16
Average= 4.03
(KJ/cycle)

Cycle 154 GMT 10/ 2/2023 14:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 26 15.11 491 193 0.19 / 620.23 2 2
2 3 1016.00 1 15.20 1781 27 0.22 / 620.26 2 2
3 7 2007.16 32 15.01 2911 1398 1.62 / 621.66 2 3
4 13 1591.04 17 15.02 2419 618 2.24 / 622.28 2 4
5 13 1162.56 17 15.02 1891 483 2.72 / 622.76 2 4
6 13 598.56 17 15.09 1166 299 3.02 / 623.06 2 4
7 13 93.72 17 15.19 496 128 3.15 / 623.19 2 6
8 13 21.72 17 15.20 395 102 3.25 / 623.29 2 6
9 8 0.12 175 15.15 348 923 4.17 / 624.21 2 14
10 14 0.12 20 15.13 351 106 4.28 / 624.32 3 19
Average= 4.03
(KJ/cycle)

Cycle 153 GMT 31/ 1/2023 16:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 27 15.11 500 204 0.20 / 616.19 2 2
2 3 983.36 -1 15.49 6 0 0.00 / 616.19 2 2
3 7 2007.28 32 15.01 2911 1398 1.60 / 617.59 2 3
4 13 1596.60 17 15.02 2420 618 2.22 / 618.20 2 3
5 13 1175.72 17 15.02 1896 484 2.70 / 618.69 2 4
6 13 610.48 17 15.08 1185 304 3.01 / 618.99 2 5
7 13 92.36 17 15.19 495 128 3.14 / 619.12 2 6
8 8 0.04 175 15.16 348 923 4.06 / 620.04 2 14
Average= 4.03
(KJ/cycle)

Cycle 152 GMT 21/ 1/2023 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 26 15.11 501 197 0.20 / 611.92 2 2
2 7 2008.96 32 15.01 2915 1400 1.60 / 613.32 2 4
3 13 1733.40 17 15.00 2599 663 2.26 / 613.99 2 3
4 13 1146.80 17 15.02 1872 478 2.74 / 614.46 2 4
5 13 707.28 17 15.06 1314 336 3.07 / 614.80 2 4
6 13 134.28 17 15.18 553 143 3.22 / 614.94 2 6
7 8 0.04 175 15.16 352 934 4.15 / 615.88 2 15
8 14 0.04 20 15.14 352 107 4.26 / 615.98 2 13
Average= 4.03
(KJ/cycle)

Cycle 151 GMT 11/ 1/2023 20:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 26 15.11 504 198 0.20 / 607.89 2 2
2 7 2010.88 32 15.01 2915 1400 1.60 / 609.29 2 2
3 13 1610.52 17 15.01 2440 623 2.22 / 609.91 2 4
4 13 1051.72 17 15.03 1749 447 2.67 / 610.36 2 4
5 13 629.80 17 15.08 1218 312 2.98 / 610.67 2 5
6 13 91.92 17 15.19 495 128 3.11 / 610.80 2 5
7 8 0.04 175 15.16 350 929 4.04 / 611.73 2 13
Average= 4.02
(KJ/cycle)

Cycle 150 GMT 1/ 1/2023 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 27 15.12 500 204 0.20 / 603.82 2 3
2 7 2007.92 32 15.01 2911 1398 1.60 / 605.22 2 3
3 13 1596.92 17 15.02 2426 619 2.22 / 605.84 2 3
4 13 1170.32 17 15.02 1903 486 2.71 / 606.33 2 4
5 13 610.08 17 15.08 1189 305 3.01 / 606.63 2 5
6 13 92.88 17 15.19 495 128 3.14 / 606.76 2 6
7 8 0.16 175 15.16 350 929 4.07 / 607.69 2 14
Average= 4.02
(KJ/cycle)

Cycle 149 GMT 23/12/2022 1: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 27 15.11 504 206 0.21 / 599.69 2 3
2 3 966.56 -1 15.49 6 0 0.00 / 599.69 2 3
3 7 2002.92 32 15.02 2913 1400 1.61 / 601.09 2 3
4 13 1602.72 17 15.02 2433 621 2.23 / 601.71 2 3
5 13 1172.76 17 15.02 1907 487 2.71 / 602.20 2 4
6 13 728.92 17 15.06 1346 345 3.06 / 602.54 2 4
7 13 141.16 17 15.18 564 146 3.20 / 602.69 2 5
8 8 -0.04 175 15.16 351 931 4.14 / 603.62 2 11
Average= 4.02
(KJ/cycle)

Cycle 148 GMT 13/12/2022 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 27 15.11 521 213 0.21 / 595.62 2 3
2 7 2010.40 33 15.01 2907 1440 1.65 / 597.06 2 3
3 13 1481.56 17 15.02 2277 581 2.23 / 597.64 2 3
4 13 1078.44 17 15.03 1794 458 2.69 / 598.10 2 4
5 13 650.56 17 15.07 1237 317 3.01 / 598.41 2 4
6 13 103.24 17 15.18 512 132 3.14 / 598.55 2 5
7 8 0.24 175 15.16 354 939 4.08 / 599.49 2 13
Average= 4.02
(KJ/cycle)

Cycle 147 GMT 3/12/2022 5:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 27 15.12 493 201 0.20 / 591.49 2 3
2 7 2002.80 32 15.02 2908 1398 1.60 / 592.89 2 3
3 13 1597.64 17 15.02 2436 622 2.22 / 593.51 2 4
4 13 1185.32 17 15.02 1928 492 2.71 / 594.00 2 4
5 13 616.80 17 15.09 1198 307 3.02 / 594.31 2 4
6 13 192.72 17 15.17 630 162 3.18 / 594.47 2 6
7 8 0.28 175 15.17 351 932 4.11 / 595.40 2 13
Average= 4.02
(KJ/cycle)

Cycle 146 GMT 23/11/2022 7:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 27 15.12 486 198 0.20 / 587.33 2 3
2 7 2006.84 32 15.02 2905 1396 1.59 / 588.72 2 2
3 13 1594.12 17 15.02 2421 618 2.21 / 589.34 2 3
4 13 1171.84 17 15.02 1901 485 2.70 / 589.83 2 5
5 13 615.48 17 15.09 1193 306 3.00 / 590.13 2 5
6 13 97.88 17 15.19 496 128 3.13 / 590.26 2 5
7 8 0.20 175 15.17 347 921 4.05 / 591.18 2 15
8 14 0.20 20 15.15 351 106 4.16 / 591.29 2 14
Average= 4.02
(KJ/cycle)

Cycle 145 GMT 13/11/2022 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 27 15.13 490 200 0.20 / 583.30 2 3
2 7 2004.44 32 15.02 2896 1392 1.59 / 584.70 2 4
3 13 1593.60 17 15.02 2406 614 2.21 / 585.31 2 3
4 13 1170.84 17 15.02 1901 485 2.69 / 585.80 2 4
5 13 602.84 17 15.09 1171 300 2.99 / 586.10 2 5
6 13 86.08 17 15.20 476 123 3.12 / 586.22 2 4
7 8 -0.12 175 15.17 343 911 4.03 / 587.13 2 14
Average= 4.02
(KJ/cycle)

Cycle 144 GMT 3/11/2022 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 27 15.12 498 203 0.20 / 579.20 2 3
2 7 2003.28 32 15.02 2887 1388 1.59 / 580.59 2 3
3 13 1730.40 17 15.01 2568 655 2.25 / 581.25 2 3
4 13 1149.56 17 15.03 1862 476 2.72 / 581.72 2 4
5 13 716.44 17 15.08 1315 337 3.06 / 582.06 2 5
6 13 133.28 17 15.19 538 139 3.20 / 582.20 2 5
7 8 0.36 175 15.18 341 906 4.10 / 583.10 2 12
Average= 4.02
(KJ/cycle)

Cycle 143 GMT 24/10/2022 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 27 15.12 506 207 0.21 / 574.99 2 3
2 7 2003.60 32 15.03 2900 1395 1.60 / 576.38 2 3
3 13 1602.60 17 15.02 2427 620 2.22 / 577.00 2 3
4 13 1182.60 17 15.03 1916 490 2.71 / 577.49 2 4
5 13 628.68 17 15.09 1208 310 3.02 / 577.80 2 4
6 13 192.40 17 15.17 628 162 3.18 / 577.97 2 5
7 8 -0.12 175 15.17 350 929 4.11 / 578.89 2 15
8 14 -0.12 20 15.15 350 106 4.22 / 579.00 2 15
Average= 4.02
(KJ/cycle)

Cycle 142 GMT 14/10/2022 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 15.12 497 203 0.20 / 570.78 2 3
2 7 2003.08 32 15.02 2894 1391 1.59 / 572.17 2 2
3 13 1582.04 17 15.03 2400 613 2.21 / 572.78 2 4
4 13 1032.28 17 15.05 1724 441 2.65 / 573.23 2 4
5 13 628.00 17 15.09 1208 310 2.96 / 573.54 2 4
6 13 93.24 17 15.20 489 126 3.08 / 573.66 2 5
7 13 26.88 17 15.21 395 102 3.19 / 573.76 2 5
8 8 0.16 175 15.17 344 913 4.10 / 574.68 2 13
9 14 0.16 20 15.14 349 106 4.21 / 574.78 2 17
Average= 4.02
(KJ/cycle)

Cycle 141 GMT 4/10/2022 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 28 15.12 503 213 0.21 / 566.74 2 2
2 7 2010.88 32 15.02 2901 1394 1.61 / 568.13 2 2
3 13 1609.00 17 15.02 2441 623 2.23 / 568.75 2 4
4 13 1075.80 17 15.04 1780 455 2.69 / 569.21 2 4
5 13 658.76 17 15.09 1245 319 3.01 / 569.53 2 5
6 13 105.40 17 15.20 505 130 3.14 / 569.66 2 5
7 8 0.40 175 15.17 346 919 4.05 / 570.58 2 13
Average= 4.02
(KJ/cycle)

Cycle 140 GMT 24/ 9/2022 19:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 28 15.13 513 217 0.22 / 562.60 2 3
2 7 2009.76 32 15.02 2896 1392 1.61 / 563.99 2 3
3 13 1597.32 17 15.02 2425 619 2.23 / 564.61 2 4
4 13 1056.48 17 15.04 1750 447 2.68 / 565.05 2 4
5 13 642.80 17 15.09 1221 313 2.99 / 565.37 2 4
6 13 105.48 17 15.20 506 131 3.12 / 565.50 2 5
7 8 -0.24 175 15.18 346 919 4.04 / 566.42 2 14
8 14 -0.24 20 15.16 349 106 4.14 / 566.52 3 15
Average= 4.02
(KJ/cycle)

Cycle 139 GMT 14/ 9/2022 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 27 15.12 515 210 0.21 / 558.35 2 2
2 7 2003.00 32 15.03 2900 1395 1.61 / 559.74 2 3
3 13 1605.20 17 15.02 2441 623 2.23 / 560.36 2 3
4 13 1179.72 17 15.03 1907 487 2.72 / 560.85 2 4
5 13 749.00 17 15.07 1364 349 3.07 / 561.20 2 5
6 13 155.12 17 15.19 577 149 3.21 / 561.35 2 6
7 8 0.32 175 15.18 347 922 4.14 / 562.27 2 11
8 14 0.32 20 15.16 350 106 4.24 / 562.38 2 23
Average= 4.02
(KJ/cycle)

Cycle 138 GMT 4/ 9/2022 23:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 28 15.13 492 208 0.21 / 554.14 2 3
2 3 982.24 -1 15.50 7 0 0.00 / 554.14 2 3
3 7 2009.96 32 15.03 2913 1401 1.61 / 555.54 2 3
4 13 1611.64 17 15.02 2445 624 2.23 / 556.16 2 3
5 13 1183.48 17 15.03 1916 490 2.72 / 556.65 2 4
6 13 616.00 17 15.10 1192 306 3.03 / 556.96 2 4
7 13 183.84 17 15.18 610 157 3.19 / 557.11 2 5
8 13 13.84 17 15.21 380 98 3.28 / 557.21 2 7
9 8 0.16 175 15.17 348 924 4.21 / 558.14 2 18
Average= 4.02
(KJ/cycle)

Cycle 137 GMT 26/ 8/2022 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 27 15.13 516 211 0.21 / 550.02 2 3
2 3 1016.84 1 15.22 1766 27 0.24 / 550.05 2 3
3 7 2008.84 33 15.02 2900 1437 1.68 / 551.49 2 4
4 13 1592.28 17 15.02 2420 618 2.29 / 552.11 2 4
5 13 1158.72 17 15.03 1894 484 2.78 / 552.59 2 4
6 13 594.84 17 15.10 1159 298 3.07 / 552.89 2 4
7 13 82.28 17 15.21 474 123 3.20 / 553.01 2 5
8 8 0.12 175 15.18 345 916 4.11 / 553.93 2 13
Average= 4.01
(KJ/cycle)

Cycle 136 GMT 16/ 8/2022 4:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 27 15.13 496 203 0.20 / 545.91 2 3
2 7 2009.92 32 15.03 2911 1400 1.60 / 547.31 2 4
3 13 1604.84 17 15.02 2427 620 2.22 / 547.93 2 3
4 13 1188.80 17 15.03 1929 493 2.72 / 548.42 2 4
5 13 624.92 17 15.10 1202 309 3.02 / 548.73 2 4
6 13 200.36 17 15.18 629 162 3.19 / 548.89 2 5
7 8 0.52 175 15.18 346 919 4.11 / 549.81 2 12
Average= 4.01
(KJ/cycle)

Cycle 135 GMT 6/ 8/2022 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 27 15.13 492 201 0.20 / 541.85 2 2
2 3 986.96 -1 15.50 6 0 0.00 / 541.85 2 2
3 7 2010.04 32 15.02 2920 1403 1.60 / 543.25 2 3
4 13 1604.44 17 15.02 2436 622 2.23 / 543.87 2 3
5 13 1180.00 17 15.03 1908 488 2.71 / 544.36 2 4
6 13 629.36 17 15.10 1212 311 3.03 / 544.67 2 4
7 13 95.64 17 15.21 490 127 3.15 / 544.80 2 5
8 8 0.16 175 15.18 342 909 4.06 / 545.71 2 15
Average= 4.01
(KJ/cycle)

Cycle 134 GMT 27/ 7/2022 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 27 15.13 492 201 0.20 / 537.67 2 2
2 3 1015.72 1 15.23 1770 27 0.23 / 537.69 2 3
3 7 2005.56 33 15.03 2903 1440 1.67 / 539.13 2 4
4 13 1597.16 17 15.02 2425 619 2.29 / 539.75 2 4
5 13 1056.20 17 15.04 1764 451 2.74 / 540.20 2 4
6 13 651.60 17 15.09 1243 319 3.06 / 540.52 2 4
7 13 53.44 17 15.21 430 111 3.17 / 540.63 2 5
8 8 -0.04 175 15.18 343 911 4.08 / 541.54 2 16
9 14 -0.04 20 15.15 345 105 4.18 / 541.65 2 16
Average= 4.01
(KJ/cycle)

Cycle 133 GMT 17/ 7/2022 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 15.14 476 202 0.20 / 533.65 2 2
2 3 964.80 -2 15.51 6 0 0.00 / 533.65 2 2
3 7 2010.00 32 15.02 2913 1400 1.60 / 535.05 2 4
4 13 1599.88 17 15.02 2420 618 2.22 / 535.67 2 3
5 13 1054.96 17 15.04 1755 449 2.67 / 536.12 2 4
6 13 643.80 17 15.09 1224 314 2.98 / 536.43 2 4
7 13 99.04 17 15.20 488 126 3.11 / 536.56 2 4
8 8 -0.08 175 15.18 341 906 4.01 / 537.46 2 12
Average= 4.01
(KJ/cycle)

Cycle 132 GMT 7/ 7/2022 12:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 28 15.14 494 209 0.21 / 529.59 2 2
2 7 2010.76 32 15.03 2907 1398 1.61 / 530.99 2 3
3 13 1601.48 17 15.02 2432 621 2.23 / 531.61 2 4
4 13 1179.08 17 15.03 1901 486 2.71 / 532.10 2 4
5 13 742.16 17 15.08 1349 346 3.06 / 532.44 2 4
6 13 82.44 17 15.21 457 118 3.18 / 532.56 2 5
7 8 0.32 175 15.19 335 891 4.07 / 533.45 2 12
Average= 4.01
(KJ/cycle)

Cycle 131 GMT 27/ 6/2022 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 28 15.14 500 212 0.21 / 525.57 2 2
2 7 2005.76 32 15.04 2907 1399 1.61 / 526.97 2 3
3 13 1608.24 17 15.03 2433 622 2.23 / 527.59 2 5
4 13 1064.00 17 15.05 1767 452 2.68 / 528.04 2 4
5 13 660.84 17 15.09 1242 319 3.00 / 528.36 2 4
6 13 124.08 17 15.20 522 135 3.14 / 528.49 2 6
7 8 -0.28 175 15.19 334 888 4.03 / 529.38 2 12
Average= 4.01
(KJ/cycle)

Cycle 130 GMT 17/ 6/2022 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 28 15.14 483 205 0.20 / 521.42 2 2
2 3 988.20 -1 15.51 7 0 0.00 / 521.42 2 2
3 3 1017.76 1 15.28 1762 27 0.23 / 521.44 2 3
4 7 2004.28 33 15.03 2902 1439 1.67 / 522.88 2 5
5 13 1591.36 17 15.03 2407 615 2.29 / 523.50 2 3
6 13 1149.24 17 15.04 1873 479 2.76 / 523.98 2 4
7 13 714.84 17 15.09 1314 337 3.10 / 524.31 2 4
8 13 122.80 17 15.21 519 134 3.24 / 524.45 2 5
9 8 0.32 175 15.19 341 906 4.14 / 525.36 2 16
Average= 4.01
(KJ/cycle)

Cycle 129 GMT 7/ 6/2022 18:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 15.14 497 211 0.21 / 517.40 2 2
2 7 2005.12 33 15.03 2903 1440 1.65 / 518.84 2 3
3 13 1601.92 17 15.03 2425 620 2.27 / 519.46 2 4
4 13 1056.48 17 15.05 1751 448 2.72 / 519.91 2 4
5 13 659.88 17 15.09 1240 318 3.04 / 520.23 2 4
6 13 24.72 17 15.23 382 99 3.14 / 520.32 2 5
7 8 0.12 175 15.19 334 888 4.02 / 521.21 2 13
Average= 4.01
(KJ/cycle)

Cycle 128 GMT 28/ 5/2022 20:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 28 15.15 503 213 0.21 / 513.31 2 3
2 7 2004.88 33 15.03 2904 1440 1.65 / 514.75 2 3
3 13 1606.92 17 15.03 2431 621 2.27 / 515.37 2 4
4 13 1069.24 17 15.04 1773 453 2.73 / 515.82 2 4
5 13 656.52 17 15.10 1246 320 3.05 / 516.14 2 4
6 13 208.24 17 15.19 636 164 3.21 / 516.30 2 5
7 8 0.12 175 15.19 333 885 4.10 / 517.19 2 13
Average= 4.01
(KJ/cycle)

Cycle 127 GMT 18/ 5/2022 22:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 15.15 493 209 0.21 / 509.09 2 2
2 7 2010.44 33 15.03 2912 1444 1.65 / 510.53 2 4
3 13 1741.04 17 15.01 2585 660 2.31 / 511.19 2 4
4 13 1150.32 17 15.04 1882 481 2.79 / 511.67 2 4
5 13 609.88 17 15.11 1183 304 3.10 / 511.98 2 5
6 13 89.84 17 15.22 476 123 3.22 / 512.10 2 5
7 8 0.28 175 15.20 334 888 4.11 / 512.99 2 14
8 14 0.28 20 15.18 338 103 4.21 / 513.09 3 13
Average= 4.01
(KJ/cycle)

Cycle 126 GMT 9/ 5/2022 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 28 15.15 486 206 0.21 / 504.94 2 2
2 7 2011.88 32 15.02 2912 1400 1.61 / 506.34 2 2
3 13 1611.56 17 15.02 2436 622 2.23 / 506.96 2 4
4 13 1195.04 17 15.03 1931 493 2.72 / 507.46 2 4
5 13 639.12 17 15.10 1215 312 3.03 / 507.77 2 4
6 13 96.88 17 15.22 485 125 3.16 / 507.90 2 5
7 8 0.80 175 15.20 332 883 4.04 / 508.78 2 15
8 14 0.80 20 15.17 333 101 4.14 / 508.88 3 15
Average= 4.01
(KJ/cycle)

Cycle 125 GMT 29/ 4/2022 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 28 15.15 482 204 0.20 / 500.88 2 2
2 7 2003.44 32 15.03 2899 1394 1.60 / 502.28 2 5
3 13 1731.64 17 15.02 2587 661 2.26 / 502.94 2 3
4 13 1155.64 17 15.04 1884 482 2.74 / 503.42 2 4
5 13 615.68 17 15.11 1189 305 3.05 / 503.73 2 4
6 13 97.64 17 15.22 485 125 3.17 / 503.85 2 4
7 8 -0.08 175 15.20 333 886 4.06 / 504.74 2 13
Average= 4.01
(KJ/cycle)

Cycle 124 GMT 19/ 4/2022 4:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 28 15.15 485 206 0.21 / 496.84 2 3
2 7 2009.96 32 15.04 2903 1397 1.60 / 498.23 2 4
3 13 1601.68 17 15.03 2412 616 2.22 / 498.85 2 3
4 13 1188.72 17 15.03 1926 492 2.71 / 499.34 2 4
5 13 641.20 17 15.11 1218 313 3.02 / 499.66 2 4
6 13 107.52 17 15.22 501 130 3.15 / 499.79 2 5
7 8 0.04 175 15.20 336 894 4.05 / 500.68 2 13
Average= 4.01
(KJ/cycle)

Cycle 123 GMT 9/ 4/2022 6:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 28 15.15 491 208 0.21 / 492.68 2 2
2 3 1022.00 1 15.24 1768 27 0.24 / 492.71 2 3
3 7 2009.76 32 15.03 2898 1394 1.63 / 494.11 2 3
4 13 1614.68 17 15.03 2437 623 2.25 / 494.73 2 3
5 13 1334.84 17 15.02 2106 538 2.79 / 495.27 2 4
6 13 736.48 17 15.09 1343 345 3.13 / 495.61 2 4
7 13 134.32 17 15.21 533 138 3.27 / 495.75 2 5
8 8 0.36 175 15.20 332 883 4.15 / 496.63 2 16
Average= 4.01
(KJ/cycle)

Cycle 122 GMT 30/ 3/2022 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 29 15.15 472 207 0.21 / 488.59 2 3
2 3 955.48 -2 15.52 6 0 0.00 / 488.59 2 3
3 7 2007.28 32 15.04 2897 1394 1.60 / 489.99 2 4
4 13 1616.76 17 15.03 2445 625 2.23 / 490.61 2 4
5 13 1191.72 17 15.04 1913 489 2.72 / 491.10 2 4
6 13 746.32 17 15.09 1358 348 3.06 / 491.45 2 5
7 13 148.60 17 15.21 550 142 3.21 / 491.59 2 5
8 8 0.04 175 15.20 333 886 4.09 / 492.48 2 13
Average= 4.00
(KJ/cycle)

Cycle 121 GMT 20/ 3/2022 11:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 28 15.15 491 208 0.21 / 484.55 2 2
2 3 1017.36 1 15.25 1773 27 0.24 / 484.58 2 3
3 7 2002.56 32 15.03 2892 1391 1.63 / 485.97 2 3
4 13 1598.28 17 15.03 2413 617 2.24 / 486.59 2 3
5 13 1179.44 17 15.04 1908 488 2.73 / 487.07 2 4
6 13 607.20 17 15.12 1169 300 3.03 / 487.37 2 4
7 13 89.76 17 15.23 473 122 3.15 / 487.50 2 4
8 8 0.16 175 15.21 334 889 4.04 / 488.38 2 13
Average= 4.00
(KJ/cycle)

Cycle 120 GMT 10/ 3/2022 13:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 15.15 478 203 0.20 / 480.41 2 2
2 7 2011.32 32 15.04 2898 1395 1.60 / 481.81 2 2
3 13 1602.12 17 15.04 2421 619 2.22 / 482.43 2 3
4 13 1189.84 17 15.04 1922 491 2.71 / 482.92 2 4
5 13 639.80 17 15.11 1213 312 3.02 / 483.23 2 5
6 13 100.44 17 15.22 488 126 3.15 / 483.36 2 5
7 8 0.12 175 15.20 333 886 4.03 / 484.24 2 12
8 14 0.12 20 15.18 332 101 4.13 / 484.34 2 13
Average= 4.00
(KJ/cycle)

Cycle 119 GMT 28/ 2/2022 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 28 15.16 473 201 0.20 / 476.36 2 2
2 7 2003.28 32 15.04 2893 1392 1.59 / 477.75 2 3
3 13 1610.00 17 15.04 2428 621 2.21 / 478.37 2 3
4 13 1196.64 17 15.04 1920 491 2.70 / 478.86 2 3
5 13 754.56 17 15.09 1364 350 3.05 / 479.21 2 5
6 13 80.68 17 15.23 458 119 3.17 / 479.33 2 4
7 8 0.16 175 15.20 330 878 4.05 / 480.21 2 13
Average= 4.00
(KJ/cycle)

Cycle 118 GMT 18/ 2/2022 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 15.15 491 208 0.21 / 472.13 2 3
2 7 2003.32 33 15.04 2889 1434 1.64 / 473.56 2 3
3 13 1741.16 17 15.02 2587 661 2.30 / 474.22 2 4
4 13 1166.56 17 15.04 1891 483 2.79 / 474.71 2 4
5 13 734.92 17 15.09 1340 344 3.13 / 475.05 2 4
6 13 80.84 17 15.23 462 120 3.25 / 475.17 2 4
7 8 0.04 175 15.20 334 888 4.14 / 476.06 2 14
8 14 0.04 20 15.18 333 101 4.24 / 476.16 2 16
Average= 4.00
(KJ/cycle)

Cycle 117 GMT 8/ 2/2022 19:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 28 15.16 485 206 0.21 / 468.02 2 2
2 7 2004.08 32 15.04 2897 1394 1.60 / 469.41 2 4
3 13 1614.16 17 15.03 2434 622 2.22 / 470.04 2 4
4 13 1073.08 17 15.06 1774 454 2.68 / 470.49 2 3
5 13 658.36 17 15.11 1237 318 2.99 / 470.81 2 4
6 13 58.92 17 15.23 423 110 3.10 / 470.92 2 4
7 8 -0.12 175 15.20 338 899 4.00 / 471.82 2 9
8 14 -0.12 20 15.18 341 104 4.11 / 471.92 2 9
Average= 4.00
(KJ/cycle)

Cycle 116 GMT 29/ 1/2022 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 15.15 485 206 0.21 / 464.00 2 2
2 7 2010.32 32 15.04 2890 1391 1.60 / 465.39 2 4
3 13 1609.64 17 15.04 2420 619 2.22 / 466.01 2 4
4 13 1191.92 17 15.04 1920 491 2.71 / 466.50 2 3
5 13 633.88 17 15.12 1201 309 3.01 / 466.81 2 4
6 13 91.28 17 15.23 471 122 3.14 / 466.94 2 5
7 8 -0.08 175 15.21 330 878 4.02 / 467.81 2 11
Average= 4.00
(KJ/cycle)

Cycle 115 GMT 19/ 1/2022 23:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 28 15.16 483 205 0.21 / 459.91 2 2
2 7 2011.56 32 15.04 2901 1396 1.60 / 461.30 2 3
3 13 1607.28 17 15.04 2426 620 2.22 / 461.92 2 3
4 13 1183.44 17 15.04 1908 488 2.71 / 462.41 2 4
5 13 753.44 17 15.09 1367 351 3.06 / 462.76 2 4
6 13 156.80 17 15.21 558 144 3.20 / 462.91 2 4
7 8 0.08 175 15.20 335 891 4.10 / 463.80 2 14
Average= 4.00
(KJ/cycle)

Cycle 114 GMT 10/ 1/2022 2: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 28 15.16 479 203 0.20 / 455.86 2 2
2 7 2003.00 32 15.05 2893 1393 1.60 / 457.25 2 3
3 13 1727.12 17 15.03 2576 658 2.25 / 457.91 2 3
4 13 1157.08 17 15.05 1884 482 2.74 / 458.39 2 3
5 13 620.48 17 15.13 1185 305 3.04 / 458.69 2 4
6 13 93.12 17 15.23 474 123 3.16 / 458.82 2 4
7 8 0.28 175 15.21 333 886 4.05 / 459.70 2 12
Average= 4.00
(KJ/cycle)

Cycle 113 GMT 31/12/2021 4:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 15.15 502 213 0.21 / 451.76 2 2
2 7 2005.60 32 15.04 2896 1394 1.61 / 453.16 2 3
3 13 1600.60 17 15.04 2424 620 2.23 / 453.78 2 4
4 13 1166.28 17 15.05 1904 487 2.71 / 454.26 2 4
5 13 728.16 17 15.10 1337 343 3.06 / 454.61 2 5
6 13 135.24 17 15.22 544 141 3.20 / 454.75 2 5
7 8 0.12 175 15.21 340 905 4.10 / 455.65 2 10
Average= 4.00
(KJ/cycle)

Cycle 112 GMT 21/12/2021 6:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 28 15.17 472 200 0.20 / 447.51 2 2
2 7 2010.68 32 15.04 2905 1398 1.60 / 448.91 2 3
3 13 1738.68 17 15.02 2587 661 2.26 / 449.57 2 3
4 13 1163.56 17 15.05 1892 484 2.74 / 450.06 2 3
5 13 726.84 17 15.10 1335 343 3.09 / 450.40 2 4
6 13 129.76 17 15.22 531 137 3.22 / 450.54 2 5
7 8 -0.04 175 15.21 341 908 4.13 / 451.44 2 13
8 14 -0.04 20 15.18 346 105 4.24 / 451.55 2 15
Average= 4.00
(KJ/cycle)

Cycle 111 GMT 11/12/2021 8:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 28 15.17 490 208 0.21 / 443.47 2 3
2 7 2002.60 32 15.05 2898 1396 1.60 / 444.87 2 4
3 13 1723.12 17 15.03 2564 655 2.26 / 445.52 2 3
4 13 1169.24 17 15.05 1894 485 2.74 / 446.01 2 4
5 13 620.36 17 15.13 1188 306 3.05 / 446.31 2 4
6 13 92.00 17 15.24 470 122 3.17 / 446.44 2 4
7 8 0.40 175 15.21 330 878 4.05 / 447.31 2 13
Average= 3.99
(KJ/cycle)

Cycle 110 GMT 1/12/2021 10:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 15.16 486 206 0.21 / 439.34 2 2
2 7 2005.88 32 15.05 2889 1391 1.60 / 440.74 2 3
3 13 1613.12 17 15.04 2421 619 2.22 / 441.35 2 3
4 13 1193.40 17 15.05 1925 493 2.71 / 441.85 2 4
5 13 637.56 17 15.13 1205 310 3.02 / 442.16 2 4
6 13 102.84 17 15.24 482 125 3.14 / 442.28 2 4
7 8 0.24 175 15.21 331 881 4.03 / 443.16 2 10
8 14 0.24 20 15.19 334 101 4.13 / 443.26 2 10
Average= 3.99
(KJ/cycle)

Cycle 109 GMT 21/11/2021 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 15.16 489 208 0.21 / 435.30 2 3
2 3 976.72 -1 15.52 6 0 0.00 / 435.30 2 3
3 7 2006.24 33 15.04 2898 1438 1.65 / 436.74 2 5
4 13 1602.00 17 15.04 2417 618 2.26 / 437.35 2 3
5 13 1175.44 17 15.05 1897 485 2.75 / 437.84 2 4
6 13 618.40 17 15.13 1182 304 3.05 / 438.14 2 4
7 13 87.40 17 15.23 462 120 3.17 / 438.26 2 5
8 8 0.08 175 15.21 329 876 4.05 / 439.14 2 12
Average= 3.99
(KJ/cycle)

Cycle 108 GMT 11/11/2021 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 28 15.16 500 212 0.21 / 431.13 2 2
2 3 1022.40 1 15.25 1786 27 0.24 / 431.16 2 3
3 7 2002.96 32 15.04 2895 1393 1.63 / 432.55 2 4
4 13 1594.08 17 15.04 2416 618 2.25 / 433.17 2 4
5 13 1170.56 17 15.05 1900 486 2.74 / 433.66 2 4
6 13 727.56 17 15.11 1331 342 3.08 / 434.00 2 5
7 13 30.96 17 15.25 387 100 3.18 / 434.10 2 4
8 8 -0.08 175 15.21 334 889 4.07 / 434.99 2 14
9 14 -0.08 20 15.19 338 103 4.17 / 435.09 2 13
Average= 3.99
(KJ/cycle)

Cycle 107 GMT 1/11/2021 17:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 28 15.16 490 208 0.21 / 427.04 2 2
2 3 988.24 -1 15.53 6 0 0.00 / 427.04 2 2
3 7 2005.52 33 15.04 2903 1441 1.65 / 428.48 2 3
4 13 1596.20 17 15.04 2418 618 2.27 / 429.10 2 3
5 13 1164.88 17 15.05 1886 483 2.75 / 429.58 2 4
6 13 724.60 17 15.11 1322 340 3.09 / 429.92 2 4
7 13 71.04 17 15.24 443 115 3.20 / 430.04 2 5
8 8 0.24 175 15.21 332 884 4.09 / 430.92 2 9
Average= 3.99
(KJ/cycle)

Cycle 106 GMT 22/10/2021 19:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 28 15.18 485 206 0.21 / 422.96 2 3
2 7 2005.40 33 15.05 2898 1439 1.65 / 424.40 2 3
3 13 1737.20 17 15.03 2583 660 2.31 / 425.06 2 5
4 13 1164.12 17 15.06 1883 482 2.79 / 425.54 2 4
5 13 615.00 17 15.14 1173 302 3.09 / 425.84 2 4
6 13 42.24 17 15.25 405 105 3.19 / 425.94 2 4
7 8 -0.04 175 15.22 333 887 4.08 / 426.83 2 15
Average= 3.99
(KJ/cycle)

Cycle 105 GMT 12/10/2021 21:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 15.16 485 206 0.21 / 419.06 2 2
2 3 973.40 -1 15.53 6 0 0.00 / 419.06 2 2
3 3 987.76 -1 15.56 6 0 0.00 / 419.06 2 2
4 7 2007.04 32 15.05 2901 1397 1.60 / 420.45 2 4
5 13 1610.84 17 15.05 2427 621 2.22 / 421.08 2 4
6 13 1183.00 17 15.05 1913 489 2.71 / 421.56 2 4
7 13 627.60 17 15.14 1197 308 3.02 / 421.87 2 4
8 8 0.20 175 15.23 329 877 3.90 / 422.75 2 11
Average= 3.99
(KJ/cycle)

Cycle 104 GMT 2/10/2021 23:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 28 15.17 485 206 0.21 / 414.87 2 2
2 3 988.36 -1 15.53 6 0 0.00 / 414.87 2 2
3 7 2003.44 32 15.05 2885 1389 1.60 / 416.25 2 3
4 13 1607.68 17 15.05 2423 620 2.22 / 416.87 2 3
5 13 1331.12 17 15.03 2083 532 2.75 / 417.41 2 3
6 13 608.60 17 15.14 1168 301 3.05 / 417.71 2 4
7 13 179.48 17 15.22 589 152 3.20 / 417.86 2 5
8 8 -0.08 175 15.22 334 890 4.09 / 418.75 2 13
9 14 -0.08 20 15.20 335 102 4.19 / 418.85 2 15
Average= 3.99
(KJ/cycle)

Cycle 103 GMT 23/ 9/2021 1:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 29 15.16 483 212 0.21 / 410.74 2 3
2 3 987.84 -1 15.53 6 0 0.00 / 410.74 2 3
3 7 2007.20 32 15.05 2898 1396 1.61 / 412.14 2 3
4 13 1730.88 17 15.03 2582 660 2.27 / 412.80 2 4
5 13 1278.32 17 15.04 2031 519 2.79 / 413.32 2 3
6 13 687.60 17 15.12 1284 330 3.12 / 413.65 2 4
7 13 116.44 17 15.24 505 131 3.25 / 413.78 2 5
8 8 0.32 175 15.22 331 882 4.13 / 414.66 2 10
Average= 3.99
(KJ/cycle)

Cycle 102 GMT 13/ 9/2021 3:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 15.18 485 206 0.21 / 406.64 2 2
2 3 1028.60 1 15.27 1775 27 0.23 / 406.66 2 3
3 7 2004.56 32 15.05 2892 1393 1.63 / 408.06 2 3
4 13 1721.96 17 15.04 2575 658 2.28 / 408.71 2 3
5 13 1158.24 17 15.06 1880 481 2.77 / 409.20 2 3
6 13 729.04 17 15.11 1327 341 3.11 / 409.54 2 4
7 13 72.04 17 15.25 441 114 3.22 / 409.65 2 5
8 8 -0.16 175 15.22 330 879 4.10 / 410.53 2 13
Average= 3.99
(KJ/cycle)

Cycle 101 GMT 3/ 9/2021 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 15.17 475 202 0.20 / 402.60 2 2
2 7 2010.52 32 15.06 2895 1395 1.60 / 403.99 2 2
3 13 1609.92 17 15.05 2430 622 2.22 / 404.61 2 3
4 13 1205.96 17 15.05 1933 495 2.71 / 405.11 2 4
5 13 769.52 17 15.10 1375 353 3.07 / 405.46 2 5
6 13 35.76 17 15.25 386 100 3.17 / 405.56 2 4
7 8 0.20 175 15.22 326 868 4.03 / 406.43 2 13
Average= 3.98
(KJ/cycle)

Cycle 100 GMT 24/ 8/2021 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 28 15.17 485 206 0.21 / 398.57 2 2
2 3 1029.00 1 15.27 1764 27 0.23 / 398.60 2 3
3 7 2003.28 32 15.06 2887 1391 1.62 / 399.99 2 3
4 13 1611.48 17 15.05 2436 623 2.25 / 400.61 2 3
5 13 1200.36 17 15.06 1935 495 2.74 / 401.11 2 4
6 13 640.96 17 15.13 1210 311 3.05 / 401.42 2 5
7 13 48.84 17 15.25 405 105 3.16 / 401.52 2 4
8 8 0.24 175 15.22 327 871 4.03 / 402.40 2 12
Average= 3.98
(KJ/cycle)

Cycle 99 GMT 14/ 8/2021 10:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 15.17 495 210 0.21 / 394.44 2 2
2 7 2007.52 33 15.05 2892 1436 1.65 / 395.88 2 3
3 13 1600.48 17 15.05 2420 619 2.27 / 396.50 2 3
4 13 1184.00 17 15.06 1913 490 2.76 / 396.99 2 4
5 13 741.88 17 15.11 1351 347 3.10 / 397.34 2 5
6 13 157.60 17 15.23 562 146 3.25 / 397.48 2 4
7 8 0.08 175 15.22 332 884 4.13 / 398.37 2 11
Average= 3.98
(KJ/cycle)

Cycle 98 GMT 4/ 8/2021 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 28 15.16 496 211 0.21 / 390.44 2 2
2 3 975.80 -1 15.53 7 0 0.00 / 390.44 2 2
3 7 2008.20 32 15.05 2890 1392 1.60 / 391.83 2 3
4 13 1601.68 17 15.05 2425 620 2.22 / 392.45 2 5
5 13 1170.68 17 15.06 1895 485 2.71 / 392.94 2 4
6 13 607.40 17 15.14 1169 301 3.01 / 393.24 2 4
7 13 21.00 17 15.26 374 97 3.11 / 393.34 2 4
8 8 0.40 175 15.22 337 898 4.00 / 394.23 2 12
Average= 3.98
(KJ/cycle)

Cycle 97 GMT 25/ 7/2021 14:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 28 15.17 478 203 0.20 / 386.31 2 2
2 7 2010.72 33 15.05 2900 1440 1.64 / 387.75 2 3
3 13 1727.60 17 15.04 2563 655 2.30 / 388.41 2 3
4 13 1155.96 17 15.07 1877 481 2.78 / 388.89 2 4
5 13 728.16 17 15.11 1323 340 3.12 / 389.23 2 4
6 13 131.32 17 15.24 515 133 3.25 / 389.36 2 4
7 8 -0.04 175 15.22 325 866 4.12 / 390.23 2 13
Average= 3.98
(KJ/cycle)

Cycle 96 GMT 15/ 7/2021 16:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 29 15.17 487 214 0.21 / 382.23 2 2
2 3 967.84 -1 15.54 6 0 0.00 / 382.23 2 2
3 7 2006.00 33 15.06 2890 1436 1.65 / 383.66 2 3
4 13 1742.12 17 15.04 2588 662 2.31 / 384.33 2 3
5 13 1180.32 17 15.06 1902 487 2.80 / 384.81 2 5
6 13 633.88 17 15.14 1198 308 3.11 / 385.12 2 4
7 13 95.80 17 15.24 468 121 3.23 / 385.24 2 4
8 8 0.00 175 15.22 326 868 4.10 / 386.11 2 11
Average= 3.98
(KJ/cycle)

Cycle 95 GMT 5/ 7/2021 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 29 15.19 472 208 0.21 / 378.09 2 2
2 7 2008.48 32 15.06 2886 1391 1.60 / 379.48 2 3
3 13 1610.80 17 15.05 2419 619 2.22 / 380.10 2 3
4 13 1197.40 17 15.06 1917 491 2.71 / 380.59 2 4
5 13 631.96 17 15.14 1189 306 3.01 / 380.90 2 4
6 13 188.04 17 15.22 587 152 3.17 / 381.05 2 4
7 8 0.20 175 15.22 325 866 4.03 / 381.91 2 15
8 14 0.20 20 15.20 332 101 4.13 / 382.01 2 15
Average= 3.98
(KJ/cycle)

Cycle 94 GMT 25/ 6/2021 21: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 15.19 470 207 0.21 / 374.09 2 2
2 7 2003.80 32 15.06 2876 1386 1.59 / 375.48 2 3
3 13 1731.00 17 15.04 2569 657 2.25 / 376.13 2 4
4 13 1154.60 17 15.07 1860 477 2.73 / 376.61 2 4
5 13 611.36 17 15.15 1163 300 3.03 / 376.91 2 4
6 8 0.52 175 15.23 327 872 3.90 / 377.78 2 10
7 14 0.52 20 15.21 332 101 4.00 / 377.88 2 10
Average= 3.98
(KJ/cycle)

Cycle 93 GMT 15/ 6/2021 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 15.18 469 206 0.21 / 370.19 2 2
2 3 980.32 -1 15.54 6 0 0.00 / 370.19 2 2
3 7 2003.08 33 15.06 2888 1435 1.64 / 371.62 2 3
4 13 1600.40 17 15.05 2410 617 2.26 / 372.24 2 4
5 13 1187.80 17 15.06 1906 488 2.75 / 372.73 2 4
6 13 619.28 17 15.14 1173 302 3.05 / 373.03 2 4
7 8 0.32 175 15.23 321 856 3.90 / 373.88 2 10
Average= 3.98
(KJ/cycle)

Cycle 92 GMT 6/ 6/2021 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 29 15.17 486 214 0.21 / 366.10 2 2
2 7 2002.52 32 15.07 2879 1388 1.60 / 367.49 2 4
3 13 1727.04 17 15.05 2570 658 2.26 / 368.15 2 3
4 13 1275.12 17 15.06 2011 515 2.77 / 368.67 2 4
5 13 700.48 17 15.13 1274 328 3.10 / 368.99 2 5
6 13 117.24 17 15.25 493 128 3.23 / 369.12 2 3
7 8 0.36 175 15.23 322 858 4.09 / 369.98 2 10
Average= 3.98
(KJ/cycle)

Cycle 91 GMT 27/ 5/2021 3:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 30 15.18 475 216 0.22 / 361.93 2 2
2 3 962.24 -2 15.54 6 0 0.00 / 361.93 2 2
3 7 2002.88 32 15.07 2885 1391 1.61 / 363.32 2 3
4 13 1723.84 17 15.04 2552 652 2.26 / 363.98 2 3
5 13 1158.72 17 15.07 1878 481 2.74 / 364.46 2 3
6 13 736.24 17 15.12 1326 341 3.08 / 364.80 2 4
7 13 133.80 17 15.24 517 134 3.22 / 364.93 2 4
8 13 25.40 17 15.26 367 95 3.31 / 365.03 2 4
9 8 0.00 175 15.22 324 863 4.17 / 365.89 2 16
Average= 3.98
(KJ/cycle)

Cycle 90 GMT 17/ 5/2021 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 29 15.19 478 211 0.21 / 357.73 2 2
2 10 1000.36 2 15.20 1705 52 0.26 / 357.78 2 3
3 3 955.60 -2 15.53 6 0 0.05 / 357.78 2 3
4 7 2005.52 32 15.07 2890 1394 1.66 / 359.18 2 4
5 13 1617.72 17 15.06 2433 623 2.28 / 359.80 2 3
6 13 1209.16 17 15.06 1933 495 2.77 / 360.29 2 3
7 13 776.20 17 15.11 1380 354 3.13 / 360.65 2 4
8 13 41.00 17 15.26 392 102 3.23 / 360.75 2 3
9 8 0.28 175 15.23 325 866 4.10 / 361.62 2 14
10 14 0.28 20 15.20 328 100 4.20 / 361.72 4 12
Average= 3.97
(KJ/cycle)

Cycle 89 GMT 7/ 5/2021 8:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 29 15.18 474 209 0.21 / 353.76 2 2
2 7 2005.24 32 15.06 2881 1388 1.60 / 355.15 2 3
3 13 1601.92 17 15.06 2420 620 2.22 / 355.77 2 3
4 13 1172.60 17 15.07 1883 482 2.70 / 356.25 2 3
5 13 609.80 17 15.15 1160 299 3.00 / 356.55 2 4
6 13 73.36 17 15.25 435 113 3.11 / 356.66 2 4
7 8 0.08 175 15.23 322 858 3.97 / 357.52 2 10
Average= 3.97
(KJ/cycle)

Cycle 88 GMT 27/ 4/2021 10:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 29 15.18 465 205 0.20 / 349.74 2 2
2 7 2002.88 33 15.07 2880 1432 1.64 / 351.17 2 4
3 13 1594.00 17 15.06 2397 614 2.25 / 351.79 2 4
4 13 1170.40 17 15.07 1884 483 2.73 / 352.27 2 4
5 13 612.60 17 15.15 1162 299 3.03 / 352.57 2 4
6 13 82.44 17 15.26 444 115 3.15 / 352.68 2 4
7 8 0.36 175 15.23 326 869 4.02 / 353.55 2 10
Average= 3.97
(KJ/cycle)

Cycle 87 GMT 17/ 4/2021 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 29 15.18 474 209 0.21 / 345.73 2 2
2 3 983.16 -1 15.54 6 0 0.00 / 345.73 2 2
3 7 2009.60 32 15.06 2892 1394 1.60 / 347.12 2 3
4 13 1607.16 17 15.06 2423 620 2.22 / 347.74 2 4
5 13 1182.16 17 15.07 1891 484 2.71 / 348.23 2 3
6 13 742.64 17 15.12 1334 343 3.05 / 348.57 2 4
7 13 71.96 17 15.26 431 112 3.16 / 348.68 2 4
8 8 0.00 175 15.23 320 853 4.01 / 349.54 2 10
Average= 3.97
(KJ/cycle)

Cycle 86 GMT 7/ 4/2021 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 29 15.19 471 207 0.21 / 341.60 2 2
2 7 2003.92 32 15.07 2884 1391 1.60 / 342.99 2 3
3 13 1602.80 17 15.06 2413 618 2.22 / 343.61 2 5
4 13 1191.12 17 15.07 1913 490 2.71 / 344.10 2 4
5 13 762.04 17 15.12 1361 350 3.06 / 344.45 2 4
6 13 83.56 17 15.25 447 116 3.17 / 344.56 2 4
7 8 0.12 175 15.23 323 861 4.03 / 345.42 2 15
8 14 0.12 20 15.21 320 97 4.13 / 345.52 2 15
Average= 3.97
(KJ/cycle)

Cycle 85 GMT 28/ 3/2021 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 29 15.19 464 204 0.20 / 337.56 2 2
2 7 2004.16 32 15.08 2886 1393 1.60 / 338.95 2 3
3 13 1733.52 17 15.05 2573 658 2.26 / 339.61 2 5
4 13 1153.72 17 15.08 1863 478 2.73 / 340.09 2 4
5 13 730.64 17 15.13 1321 340 3.07 / 340.43 2 4
6 13 72.56 17 15.26 432 112 3.18 / 340.54 2 4
7 8 0.20 175 15.24 319 851 4.04 / 341.39 2 16
Average= 3.97
(KJ/cycle)

Cycle 84 GMT 18/ 3/2021 19:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 29 15.20 451 199 0.20 / 333.59 2 2
2 7 2008.76 32 15.07 2888 1393 1.59 / 334.98 2 3
3 13 1606.60 17 15.07 2422 620 2.21 / 335.60 2 3
4 13 1191.80 17 15.07 1910 489 2.70 / 336.09 2 4
5 13 639.44 17 15.14 1206 310 3.01 / 336.40 2 4
6 13 52.36 17 15.27 403 105 3.12 / 336.50 2 4
7 8 0.08 175 15.24 319 851 3.97 / 337.35 2 15
Average= 3.97
(KJ/cycle)

Cycle 83 GMT 8/ 3/2021 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 29 15.19 457 201 0.20 / 329.61 2 2
2 7 2004.20 32 15.07 2880 1389 1.59 / 331.00 2 3
3 13 1601.40 17 15.07 2415 619 2.21 / 331.62 2 4
4 13 1195.12 17 15.07 1916 491 2.70 / 332.11 2 3
5 13 641.48 17 15.15 1208 311 3.01 / 332.42 2 4
6 13 99.72 17 15.25 471 122 3.13 / 332.54 2 4
7 8 -0.04 175 15.24 316 843 3.98 / 333.39 2 11
Average= 3.97
(KJ/cycle)

Cycle 82 GMT 26/ 2/2021 23:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 29 15.19 467 206 0.21 / 325.61 2 2
2 3 985.84 -1 15.54 6 0 0.00 / 325.61 2 2
3 7 2003.24 32 15.07 2882 1390 1.60 / 327.00 2 3
4 13 1594.12 17 15.07 2411 618 2.21 / 327.61 2 4
5 13 1172.56 17 15.07 1891 484 2.70 / 328.10 2 4
6 13 733.92 17 15.13 1332 343 3.04 / 328.44 2 4
7 13 61.32 17 15.27 421 109 3.15 / 328.55 2 4
8 8 0.36 175 15.24 323 861 4.01 / 329.41 2 11
Average= 3.97
(KJ/cycle)

Cycle 81 GMT 17/ 2/2021 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 29 15.20 455 201 0.20 / 321.60 2 2
2 7 2009.40 33 15.07 2890 1437 1.64 / 323.03 2 2
3 13 1603.44 17 15.06 2420 620 2.26 / 323.65 2 4
4 13 1173.76 17 15.08 1896 486 2.74 / 324.14 2 3
5 13 617.28 17 15.15 1178 303 3.05 / 324.44 2 4
6 13 45.52 17 15.27 405 105 3.15 / 324.55 2 4
7 8 -0.08 175 15.24 320 853 4.01 / 325.40 2 10
Average= 3.97
(KJ/cycle)

Cycle 80 GMT 7/ 2/2021 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 29 15.20 461 203 0.20 / 317.60 2 2
2 7 2004.20 33 15.07 2886 1435 1.64 / 319.03 2 3
3 13 1601.28 17 15.07 2409 617 2.26 / 319.65 2 4
4 13 1176.56 17 15.08 1895 486 2.74 / 320.14 2 3
5 13 618.08 17 15.15 1173 302 3.04 / 320.44 2 5
6 13 46.56 17 15.27 396 103 3.15 / 320.54 2 4
7 8 0.36 175 15.24 320 853 4.00 / 321.40 2 13
Average= 3.97
(KJ/cycle)

Cycle 79 GMT 28/ 1/2021 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 15.20 473 216 0.22 / 313.62 2 2
2 3 982.28 -1 15.55 6 0 0.00 / 313.62 2 2
3 7 2004.48 32 15.08 2889 1394 1.61 / 315.02 2 3
4 13 1607.80 17 15.07 2421 620 2.23 / 315.64 2 5
5 13 1188.76 17 15.08 1916 491 2.72 / 316.13 2 3
6 13 638.16 17 15.15 1208 311 3.03 / 316.44 2 4
7 13 52.36 17 15.27 410 106 3.14 / 316.55 2 4
8 8 0.00 175 15.24 319 851 3.99 / 317.40 2 13
Average= 3.97
(KJ/cycle)

Cycle 78 GMT 18/ 1/2021 8:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 15.21 471 208 0.21 / 309.62 2 2
2 3 1025.52 1 15.29 1766 27 0.23 / 309.64 2 3
3 7 2010.64 32 15.07 2894 1396 1.63 / 311.04 2 3
4 13 1602.56 17 15.07 2422 620 2.25 / 311.66 2 3
5 13 1172.40 17 15.08 1899 487 2.74 / 312.15 2 4
6 13 610.36 17 15.16 1168 301 3.04 / 312.45 2 4
7 13 44.08 17 15.27 397 103 3.14 / 312.55 2 4
8 8 0.40 175 15.24 321 856 4.00 / 313.41 2 13
Average= 3.97
(KJ/cycle)

Cycle 77 GMT 8/ 1/2021 10:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 29 15.21 467 206 0.21 / 305.60 2 2
2 7 2002.64 32 15.08 2889 1394 1.60 / 307.00 2 3
3 13 1594.64 17 15.08 2404 616 2.22 / 307.61 2 4
4 13 1178.04 17 15.09 1897 487 2.70 / 308.10 2 3
5 13 744.08 17 15.14 1340 345 3.05 / 308.45 2 5
6 13 66.72 17 15.28 426 111 3.16 / 308.56 2 4
7 8 -0.16 175 15.25 319 851 4.01 / 309.41 2 12
Average= 3.97
(KJ/cycle)

Cycle 76 GMT 29/12/2020 12:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 29 15.21 471 208 0.21 / 301.53 2 3
2 7 2002.84 32 15.09 2884 1393 1.60 / 302.92 2 3
3 13 1725.04 17 15.07 2563 657 2.26 / 303.58 2 3
4 13 1268.84 17 15.08 2013 516 2.77 / 304.10 2 4
5 13 686.12 17 15.16 1268 327 3.10 / 304.42 2 5
6 13 57.28 17 15.29 413 107 3.21 / 304.53 2 4
7 8 0.00 175 15.26 325 868 4.08 / 305.40 2 14
Average= 3.97
(KJ/cycle)

Cycle 75 GMT 19/12/2020 14:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 29 15.21 486 214 0.21 / 297.47 2 2
2 3 1018.20 1 15.30 1780 27 0.24 / 297.50 2 3
3 7 2005.12 32 15.08 2901 1400 1.64 / 298.90 2 3
4 13 1607.04 17 15.08 2434 624 2.27 / 299.52 2 3
5 13 1184.48 17 15.09 1912 490 2.76 / 300.01 2 4
6 13 626.88 17 15.17 1205 311 3.07 / 300.32 2 4
7 13 92.96 17 15.28 473 123 3.19 / 300.45 2 4
8 8 0.04 175 15.25 329 878 4.07 / 301.32 2 14
Average= 3.96
(KJ/cycle)

Cycle 74 GMT 9/12/2020 16:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 28 15.21 483 206 0.21 / 293.40 2 2
2 3 1025.56 1 15.29 1781 27 0.23 / 293.43 2 4
3 7 2009.52 32 15.09 2902 1401 1.63 / 294.83 2 3
4 13 1603.52 17 15.08 2431 623 2.26 / 295.45 2 4
5 13 1175.68 17 15.10 1898 487 2.74 / 295.94 2 4
6 13 622.68 17 15.17 1195 308 3.05 / 296.25 2 4
7 13 85.96 17 15.28 468 122 3.17 / 296.37 2 5
8 8 0.32 175 15.26 331 884 4.06 / 297.26 2 14
Average= 3.96
(KJ/cycle)

Cycle 73 GMT 29/11/2020 19: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 28 15.21 488 208 0.21 / 289.35 2 2
2 7 2008.04 33 15.08 2907 1447 1.65 / 290.80 2 3
3 13 1595.76 17 15.08 2422 621 2.28 / 291.42 2 4
4 13 1052.36 17 15.11 1744 448 2.72 / 291.87 2 5
5 13 638.28 17 15.17 1216 314 3.04 / 292.18 2 5
6 13 93.68 17 15.28 478 124 3.16 / 292.30 2 5
7 8 -0.08 175 15.25 335 894 4.06 / 293.20 2 12
Average= 3.96
(KJ/cycle)

Cycle 72 GMT 19/11/2020 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.21 477 203 0.20 / 285.28 2 3
2 7 2003.92 32 15.08 2894 1397 1.60 / 286.68 2 3
3 13 1585.60 17 15.08 2403 616 2.22 / 287.30 2 4
4 13 1301.60 17 15.08 2055 527 2.74 / 287.82 2 4
5 13 572.80 17 15.19 1132 292 3.03 / 288.12 2 5
6 13 68.84 17 15.29 445 116 3.15 / 288.23 2 4
7 8 0.04 175 15.26 341 911 4.06 / 289.14 2 14
Average= 3.96
(KJ/cycle)

Cycle 71 GMT 9/11/2020 23:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 28 15.21 501 213 0.21 / 281.20 2 2
2 3 1016.20 1 15.30 1765 27 0.24 / 281.23 2 3
3 7 2005.64 32 15.09 2903 1402 1.64 / 282.63 2 3
4 13 1599.56 17 15.09 2431 624 2.27 / 283.26 2 4
5 13 1175.68 17 15.10 1914 491 2.76 / 283.75 2 3
6 13 617.84 17 15.18 1192 308 3.06 / 284.05 2 5
7 13 91.76 17 15.28 479 124 3.19 / 284.18 2 5
8 8 0.16 175 15.26 338 903 4.09 / 285.08 2 15
Average= 3.96
(KJ/cycle)

Cycle 70 GMT 31/10/2020 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 15.22 492 210 0.21 / 277.19 2 3
2 7 2007.24 32 15.09 2898 1399 1.61 / 278.59 2 3
3 13 1587.28 17 15.09 2406 617 2.23 / 279.20 2 3
4 13 1157.88 17 15.10 1876 482 2.71 / 279.69 2 4
5 13 598.60 17 15.19 1161 300 3.01 / 279.99 2 4
6 13 35.20 17 15.30 397 103 3.11 / 280.09 2 5
7 8 -0.20 175 15.26 337 900 4.01 / 280.99 2 12
Average= 3.96
(KJ/cycle)

Cycle 69 GMT 21/10/2020 3:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 28 15.23 483 206 0.21 / 273.12 2 3
2 7 2007.64 32 15.09 2898 1399 1.61 / 274.52 2 3
3 13 1587.32 17 15.09 2408 618 2.22 / 275.14 2 4
4 13 1165.20 17 15.11 1889 485 2.71 / 275.62 2 4
5 13 725.96 17 15.16 1322 341 3.05 / 275.96 2 4
6 13 64.08 17 15.29 437 114 3.16 / 276.08 2 4
7 8 -0.04 175 15.27 338 903 4.07 / 276.98 2 15
Average= 3.96
(KJ/cycle)

Cycle 68 GMT 11/10/2020 5:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 27 15.21 497 204 0.20 / 269.25 2 3
2 3 1020.52 1 15.29 1779 27 0.23 / 269.28 2 3
3 7 2004.28 32 15.09 2888 1395 1.63 / 270.67 2 3
4 13 1594.80 17 15.09 2418 620 2.25 / 271.29 2 3
5 13 1043.16 17 15.13 1734 446 2.69 / 271.74 2 4
6 13 521.68 17 15.21 1056 273 2.97 / 272.01 2 5
7 8 0.36 175 15.28 337 901 3.87 / 272.91 2 9
Average= 3.96
(KJ/cycle)

Cycle 67 GMT 1/10/2020 7:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 27 15.22 494 203 0.20 / 265.25 2 3
2 7 2004.52 32 15.09 2885 1393 1.60 / 266.64 2 4
3 13 1593.24 17 15.10 2419 621 2.22 / 267.26 2 3
4 13 1049.92 17 15.13 1745 449 2.67 / 267.71 2 4
5 13 633.20 17 15.18 1214 313 2.98 / 268.03 2 4
6 13 26.40 17 15.31 392 102 3.08 / 268.13 2 5
7 8 0.28 175 15.27 344 919 4.00 / 269.05 2 12
Average= 3.96
(KJ/cycle)

Cycle 66 GMT 21/ 9/2020 9:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 27 15.22 505 208 0.21 / 261.01 2 3
2 7 2003.96 32 15.10 2890 1396 1.60 / 262.41 2 3
3 13 1598.12 17 15.10 2423 622 2.23 / 263.03 2 4
4 13 1167.72 17 15.12 1885 485 2.71 / 263.52 2 4
5 13 615.08 17 15.20 1186 306 3.02 / 263.82 2 5
6 13 80.48 17 15.30 461 120 3.14 / 263.94 2 4
7 13 21.04 17 15.31 378 98 3.24 / 264.04 2 5
8 8 -0.16 175 15.27 338 903 4.14 / 264.94 2 14
9 14 -0.16 20 15.25 337 103 4.24 / 265.05 4 16
Average= 3.96
(KJ/cycle)

Cycle 65 GMT 11/ 9/2020 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 27 15.22 505 208 0.21 / 257.06 2 3
2 7 2010.08 33 15.09 2908 1448 1.66 / 258.50 2 3
3 13 1588.08 17 15.10 2404 617 2.27 / 259.12 2 4
4 13 1038.40 17 15.14 1733 446 2.72 / 259.57 2 4
5 13 613.76 17 15.19 1181 305 3.02 / 259.87 2 5
6 8 0.32 175 15.28 349 933 3.96 / 260.80 2 12
Average= 3.95
(KJ/cycle)

Cycle 64 GMT 1/ 9/2020 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 27 15.23 502 206 0.21 / 252.99 2 2
2 3 1021.88 1 15.29 1781 27 0.23 / 253.02 2 4
3 7 2004.96 32 15.10 2906 1404 1.64 / 254.43 2 3
4 13 1598.60 17 15.10 2422 622 2.26 / 255.05 2 5
5 13 1036.28 17 15.14 1723 443 2.70 / 255.49 2 4
6 13 631.16 17 15.19 1208 312 3.01 / 255.80 2 4
7 13 46.84 17 15.31 423 110 3.13 / 255.91 2 5
8 8 0.12 175 15.27 350 935 4.06 / 256.85 2 18
Average= 3.95
(KJ/cycle)

Cycle 63 GMT 22/ 8/2020 15:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 27 15.22 501 206 0.21 / 248.96 2 3
2 7 2003.08 32 15.10 2887 1395 1.60 / 250.36 2 3
3 13 1585.60 17 15.11 2399 616 2.22 / 250.97 2 3
4 13 1150.04 17 15.13 1867 480 2.70 / 251.45 2 4
5 13 583.48 17 15.21 1140 295 2.99 / 251.75 2 5
6 13 67.72 17 15.31 452 118 3.11 / 251.86 2 4
7 8 0.32 175 15.28 345 923 4.03 / 252.79 2 16
Average= 3.95
(KJ/cycle)

Cycle 62 GMT 12/ 8/2020 17:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 27 15.23 519 213 0.21 / 244.80 2 3
2 7 2004.16 32 15.10 2893 1398 1.61 / 246.20 2 3
3 13 1596.28 17 15.10 2418 621 2.23 / 246.82 2 4
4 13 1049.84 17 15.14 1748 450 2.68 / 247.27 2 5
5 13 627.80 17 15.20 1200 310 2.99 / 247.58 2 5
6 13 186.24 17 15.29 612 159 3.15 / 247.74 2 6
7 8 -0.12 175 15.28 342 915 4.07 / 248.65 2 11
8 14 -0.12 20 15.26 345 105 4.17 / 248.76 2 16
Average= 3.95
(KJ/cycle)

Cycle 61 GMT 2/ 8/2020 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 27 15.23 506 208 0.21 / 240.79 2 3
2 7 2004.16 32 15.09 2900 1400 1.61 / 242.19 2 3
3 13 1585.04 17 15.10 2401 616 2.22 / 242.80 2 3
4 13 1026.64 17 15.15 1716 442 2.67 / 243.25 2 5
5 13 611.12 17 15.20 1181 305 2.97 / 243.55 2 5
6 13 38.44 17 15.32 411 107 3.08 / 243.66 2 5
7 8 0.44 175 15.28 346 925 4.00 / 244.58 2 12
Average= 3.94
(KJ/cycle)

Cycle 60 GMT 23/ 7/2020 21: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 27 15.24 500 206 0.21 / 236.72 2 3
2 7 2002.28 32 15.11 2890 1397 1.60 / 238.12 2 3
3 13 1578.24 17 15.11 2394 615 2.22 / 238.73 2 4
4 13 1146.68 17 15.13 1860 478 2.70 / 239.21 2 4
5 13 582.32 17 15.22 1142 295 2.99 / 239.51 2 5
6 13 148.64 17 15.30 562 146 3.14 / 239.65 2 5
7 8 -0.16 175 15.29 346 926 4.06 / 240.58 2 14
Average= 3.94
(KJ/cycle)

Cycle 59 GMT 13/ 7/2020 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 27 15.24 490 202 0.20 / 232.68 2 3
2 7 2001.80 32 15.10 2897 1400 1.60 / 234.08 2 3
3 13 1579.60 17 15.11 2399 616 2.22 / 234.70 2 4
4 13 1141.68 17 15.14 1855 477 2.70 / 235.17 2 4
5 13 556.28 17 15.22 1113 288 2.98 / 235.46 2 5
6 13 64.80 17 15.32 452 118 3.10 / 235.58 2 5
7 8 -0.12 175 15.29 350 937 4.04 / 236.52 2 14
Average= 3.94
(KJ/cycle)

Cycle 58 GMT 4/ 7/2020 1:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 28 15.24 503 215 0.21 / 228.60 2 3
2 3 969.56 -1 15.57 5 0 0.00 / 228.60 2 3
3 7 2007.04 33 15.10 2886 1438 1.65 / 230.04 2 4
4 13 1606.12 17 15.11 2426 623 2.28 / 230.67 2 5
5 13 1165.00 17 15.13 1889 486 2.76 / 231.15 2 5
6 13 588.04 17 15.22 1151 298 3.06 / 231.45 2 5
7 13 33.84 17 15.33 406 106 3.17 / 231.56 2 4
8 8 0.16 175 15.29 345 923 4.09 / 232.48 2 15
Average= 3.94
(KJ/cycle)

Cycle 57 GMT 24/ 6/2020 3:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 27 15.24 516 212 0.21 / 224.46 2 3
2 3 1020.00 1 15.29 1784 27 0.24 / 224.48 2 4
3 7 2004.68 32 15.11 2903 1404 1.64 / 225.89 2 3
4 13 1596.12 17 15.11 2422 622 2.27 / 226.51 2 4
5 13 1172.44 17 15.14 1901 489 2.75 / 227.00 2 5
6 13 722.88 17 15.19 1333 344 3.10 / 227.34 2 5
7 13 71.40 17 15.32 459 120 3.22 / 227.46 2 5
8 8 -0.12 175 15.29 347 928 4.15 / 228.39 2 15
Average= 3.94
(KJ/cycle)

Cycle 56 GMT 14/ 6/2020 5:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 28 15.24 504 215 0.22 / 220.32 2 3
2 3 961.04 -2 15.58 6 0 0.00 / 220.32 2 3
3 7 2008.84 32 15.11 2902 1403 1.62 / 221.73 2 3
4 13 1603.84 17 15.11 2431 624 2.24 / 222.35 2 5
5 13 1169.28 17 15.14 1892 487 2.73 / 222.84 2 4
6 13 743.60 17 15.19 1363 352 3.08 / 223.19 2 5
7 13 81.00 17 15.32 470 122 3.20 / 223.31 2 5
8 8 0.20 175 15.30 348 932 4.14 / 224.24 2 10
Average= 3.93
(KJ/cycle)

Cycle 55 GMT 4/ 6/2020 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 27 15.25 513 211 0.21 / 216.24 2 3
2 10 1018.20 2 15.21 1763 54 0.26 / 216.29 2 4
3 3 954.92 -2 15.57 6 0 0.05 / 216.29 2 4
4 7 2004.32 32 15.11 2892 1398 1.66 / 217.69 2 3
5 13 1586.96 17 15.12 2411 620 2.28 / 218.31 2 3
6 13 1024.00 17 15.16 1712 441 2.72 / 218.75 2 5
7 13 598.68 17 15.22 1174 304 3.03 / 219.06 2 5
8 13 77.80 17 15.33 465 121 3.15 / 219.18 2 5
9 8 0.28 175 15.30 347 929 4.08 / 220.11 2 13
Average= 3.93
(KJ/cycle)

Cycle 54 GMT 25/ 5/2020 9:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 15.24 506 216 0.22 / 212.03 2 2
2 3 978.08 -1 15.58 7 0 0.00 / 212.03 2 2
3 7 2012.52 32 15.11 2909 1407 1.62 / 213.44 2 3
4 13 1619.92 17 15.11 2461 632 2.25 / 214.07 2 3
5 13 1186.04 17 15.14 1920 494 2.75 / 214.57 2 5
6 13 602.36 17 15.23 1175 304 3.05 / 214.87 2 5
7 13 88.88 17 15.32 487 127 3.18 / 215.00 2 5
8 8 -0.04 175 15.30 346 926 4.11 / 215.92 2 11
9 14 -0.04 20 15.28 348 106 4.21 / 216.03 2 21
Average= 3.93
(KJ/cycle)

Cycle 53 GMT 15/ 5/2020 11:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 26 15.25 519 206 0.21 / 207.97 2 3
2 3 1055.28 2 15.27 1831 56 0.26 / 208.03 2 4
3 7 2010.56 32 15.12 2906 1406 1.67 / 209.44 2 3
4 13 1478.56 17 15.13 2280 586 2.25 / 210.02 2 4
5 13 964.36 17 15.18 1644 424 2.68 / 210.45 2 4
6 13 571.44 17 15.23 1133 293 2.97 / 210.74 2 5
7 13 134.36 17 15.31 545 142 3.11 / 210.88 2 6
8 8 0.40 175 15.30 349 934 4.05 / 211.82 2 15
Average= 3.92
(KJ/cycle)

Cycle 52 GMT 5/ 5/2020 13: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 26 15.25 494 196 0.20 / 203.97 2 2
2 7 2002.84 32 15.11 2883 1394 1.59 / 205.37 2 3
3 13 1579.68 17 15.13 2396 616 2.21 / 205.98 2 4
4 13 1021.00 17 15.17 1712 442 2.65 / 206.42 2 4
5 13 588.08 17 15.23 1155 299 2.95 / 206.72 2 5
6 13 67.04 17 15.34 455 119 3.07 / 206.84 2 5
7 8 0.20 175 15.31 346 927 3.99 / 207.77 2 13
Average= 3.92
(KJ/cycle)

Cycle 51 GMT 25/ 4/2020 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 26 15.26 508 202 0.20 / 199.97 2 3
2 7 2006.96 32 15.11 2897 1401 1.60 / 201.37 2 3
3 13 1576.00 17 15.12 2399 617 2.22 / 201.99 2 4
4 13 1016.00 17 15.18 1696 438 2.66 / 202.43 2 4
5 13 601.80 17 15.23 1168 302 2.96 / 202.73 2 4
6 13 80.00 17 15.34 469 122 3.08 / 202.85 2 5
7 8 0.08 175 15.31 345 924 4.01 / 203.78 2 14
Average= 3.92
(KJ/cycle)

Cycle 50 GMT 15/ 4/2020 17: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 26 15.26 505 200 0.20 / 196.03 2 3
2 7 2007.56 32 15.11 2905 1405 1.60 / 197.44 2 3
3 13 1450.24 17 15.14 2248 579 2.18 / 198.02 2 4
4 13 1027.16 17 15.17 1726 445 2.63 / 198.46 2 5
5 13 485.56 17 15.26 1029 267 2.90 / 198.73 2 4
6 13 48.24 17 15.34 426 111 3.01 / 198.84 2 6
7 8 -0.48 175 15.31 348 932 3.94 / 199.77 2 16
Average= 3.92
(KJ/cycle)

Cycle 49 GMT 5/ 4/2020 18:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 26 15.25 504 200 0.20 / 191.98 2 3
2 3 983.64 -1 15.58 6 0 0.00 / 191.98 2 3
3 7 2004.08 33 15.11 2911 1452 1.65 / 193.43 2 4
4 13 1574.88 17 15.13 2404 618 2.27 / 194.05 2 4
5 13 1003.88 17 15.18 1697 438 2.71 / 194.49 2 4
6 13 572.32 17 15.24 1142 296 3.00 / 194.78 2 5
7 13 64.36 17 15.34 455 119 3.12 / 194.90 2 5
8 8 0.36 175 15.31 347 930 4.05 / 195.83 2 17
Average= 3.92
(KJ/cycle)

Cycle 48 GMT 26/ 3/2020 20:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 26 15.27 495 197 0.20 / 187.80 2 3
2 7 2004.88 32 15.12 2911 1408 1.60 / 189.21 2 3
3 13 1591.56 17 15.13 2427 624 2.23 / 189.84 2 4
4 13 1153.68 17 15.15 1891 487 2.72 / 190.32 2 4
5 13 566.68 17 15.25 1139 295 3.01 / 190.62 2 5
6 13 74.96 17 15.34 474 124 3.14 / 190.74 2 5
7 8 0.12 175 15.31 347 930 4.06 / 191.67 2 13
8 14 0.12 20 15.29 348 106 4.17 / 191.78 3 14
Average= 3.91
(KJ/cycle)

Cycle 47 GMT 16/ 3/2020 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 26 15.26 509 202 0.20 / 183.79 2 3
2 7 2007.00 32 15.11 2914 1409 1.61 / 185.20 2 3
3 13 1582.48 17 15.13 2408 619 2.23 / 185.82 2 4
4 13 1011.80 17 15.18 1707 441 2.67 / 186.26 2 4
5 13 585.64 17 15.25 1160 301 2.97 / 186.56 2 5
6 13 67.84 17 15.35 463 121 3.09 / 186.68 2 5
7 8 0.12 175 15.32 347 930 4.02 / 187.61 2 13
Average= 3.91
(KJ/cycle)

Cycle 46 GMT 7/ 3/2020 0:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 27 15.26 511 211 0.21 / 179.75 2 3
2 3 974.12 -1 15.59 7 0 0.00 / 179.75 2 3
3 7 2005.52 32 15.12 2907 1407 1.62 / 181.16 2 3
4 13 1463.96 17 15.15 2264 583 2.20 / 181.74 2 4
5 13 1057.36 17 15.18 1757 453 2.65 / 182.20 2 4
6 13 622.52 17 15.24 1207 313 2.97 / 182.51 2 5
7 13 85.08 17 15.34 490 128 3.09 / 182.64 2 5
8 8 0.32 175 15.31 354 948 4.04 / 183.59 2 13
Average= 3.91
(KJ/cycle)

Cycle 45 GMT 26/ 2/2020 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 27 15.27 511 211 0.21 / 175.75 2 3
2 7 2004.84 32 15.12 2909 1407 1.62 / 177.16 2 3
3 13 1571.44 17 15.14 2401 618 2.24 / 177.78 2 4
4 13 1006.72 17 15.19 1696 438 2.67 / 178.22 2 5
5 13 460.12 17 15.28 997 259 2.93 / 178.47 2 5
6 13 81.12 17 15.35 481 126 3.06 / 178.60 2 6
7 8 0.36 175 15.32 352 944 4.00 / 179.54 2 15
Average= 3.90
(KJ/cycle)

Cycle 44 GMT 16/ 2/2020 3:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 26 15.27 503 200 0.20 / 171.57 2 2
2 3 1034.00 1 15.31 1800 28 0.23 / 171.60 2 4
3 7 2003.00 32 15.12 2911 1408 1.64 / 173.01 2 3
4 13 1578.40 17 15.14 2417 622 2.26 / 173.63 2 5
5 13 1018.36 17 15.19 1723 445 2.70 / 174.07 2 5
6 13 585.60 17 15.25 1163 302 3.00 / 174.38 2 4
7 13 75.76 17 15.35 468 122 3.13 / 174.50 2 6
8 8 0.24 175 15.32 349 936 4.06 / 175.43 2 17
9 14 0.24 20 15.30 352 108 4.17 / 175.54 2 21
Average= 3.90
(KJ/cycle)

Cycle 43 GMT 6/ 2/2020 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 26 15.27 504 200 0.20 / 167.46 2 2
2 7 2002.20 32 15.13 2907 1407 1.61 / 168.86 2 3
3 13 1727.36 17 15.12 2589 665 2.27 / 169.53 2 3
4 13 1002.52 17 15.20 1689 436 2.71 / 169.97 2 4
5 13 593.88 17 15.25 1173 304 3.01 / 170.27 2 5
6 13 158.24 17 15.33 590 154 3.17 / 170.42 2 6
7 8 0.32 175 15.32 353 946 4.11 / 171.37 2 18
Average= 3.89
(KJ/cycle)

Cycle 42 GMT 27/ 1/2020 7:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 26 15.28 506 201 0.20 / 163.23 2 3
2 7 2007.68 32 15.13 2914 1411 1.61 / 164.64 2 3
3 13 1592.08 17 15.14 2426 624 2.24 / 165.26 2 4
4 13 1035.68 17 15.19 1737 449 2.68 / 165.71 2 5
5 13 498.60 17 15.28 1040 270 2.95 / 165.98 2 5
6 13 50.84 17 15.36 443 116 3.07 / 166.10 2 5
7 13 4.00 17 15.36 377 98 3.17 / 166.19 2 8
8 8 -0.04 175 15.32 356 954 4.12 / 167.15 2 15
9 14 -0.04 20 15.30 354 108 4.23 / 167.26 2 19
Average= 3.89
(KJ/cycle)

Cycle 41 GMT 17/ 1/2020 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 26 15.28 498 198 0.20 / 159.23 2 3
2 7 2005.84 32 15.12 2915 1410 1.61 / 160.64 2 3
3 13 1559.00 17 15.15 2372 611 2.22 / 161.26 2 4
4 13 988.08 17 15.20 1671 432 2.65 / 161.69 2 4
5 13 564.40 17 15.26 1129 293 2.94 / 161.98 2 5
6 13 32.20 17 15.37 409 107 3.05 / 162.09 2 5
7 8 0.28 175 15.33 350 939 3.99 / 163.03 2 17
Average= 3.88
(KJ/cycle)

Cycle 40 GMT 7/ 1/2020 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 25 15.28 505 193 0.19 / 155.16 2 3
2 7 2006.80 33 15.12 2901 1447 1.64 / 156.61 2 3
3 13 1585.72 17 15.14 2420 623 2.26 / 157.23 2 4
4 13 1014.40 17 15.20 1709 442 2.70 / 157.67 2 4
5 13 577.24 17 15.26 1147 298 3.00 / 157.97 2 5
6 13 60.20 17 15.36 454 119 3.12 / 158.09 2 6
7 8 0.20 175 15.33 354 950 4.07 / 159.04 2 17
Average= 3.88
(KJ/cycle)

Cycle 39 GMT 28/12/2019 12:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 25 15.28 505 193 0.19 / 151.18 2 3
2 7 2006.56 32 15.12 2909 1407 1.60 / 152.59 2 3
3 13 1575.20 17 15.15 2402 619 2.22 / 153.21 2 3
4 13 997.80 17 15.20 1685 435 2.65 / 153.64 2 5
5 13 440.92 17 15.29 966 251 2.91 / 153.90 2 5
6 13 72.24 17 15.36 469 122 3.03 / 154.02 2 6
7 8 0.32 175 15.33 353 947 3.98 / 154.97 2 13
Average= 3.87
(KJ/cycle)

Cycle 38 GMT 18/12/2019 14:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 25 15.28 510 195 0.19 / 147.21 2 2
2 7 2003.16 32 15.13 2908 1408 1.60 / 148.62 2 3
3 13 1572.88 17 15.15 2401 618 2.22 / 149.24 2 4
4 13 989.92 17 15.21 1683 435 2.66 / 149.68 2 4
5 13 439.36 17 15.30 971 253 2.91 / 149.93 2 5
6 13 36.40 17 15.38 427 112 3.02 / 150.04 2 5
7 8 -0.12 175 15.33 354 950 3.97 / 150.99 2 16
Average= 3.87
(KJ/cycle)

Cycle 37 GMT 8/12/2019 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 25 15.28 514 196 0.20 / 143.21 2 3
2 7 2001.84 32 15.13 2909 1408 1.60 / 144.61 2 3
3 13 1597.88 17 15.14 2436 627 2.23 / 145.24 2 4
4 13 1024.40 17 15.20 1725 446 2.68 / 145.69 2 5
5 13 455.52 17 15.29 995 259 2.94 / 145.95 2 5
6 13 41.48 17 15.38 432 113 3.05 / 146.06 2 5
7 8 0.20 175 15.34 358 961 4.01 / 147.02 2 18
Average= 3.87
(KJ/cycle)

Cycle 36 GMT 28/11/2019 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 25 15.28 513 196 0.20 / 139.23 2 3
2 7 2003.84 33 15.13 2913 1454 1.65 / 140.69 2 3
3 13 1446.72 17 15.17 2250 580 2.23 / 141.27 2 4
4 13 911.00 17 15.22 1575 408 2.64 / 141.67 2 6
5 13 496.88 17 15.29 1043 271 2.91 / 141.95 2 5
6 13 23.44 17 15.38 409 107 3.02 / 142.05 2 6
7 8 0.16 175 15.33 357 958 3.97 / 143.01 2 17
Average= 3.87
(KJ/cycle)

Cycle 35 GMT 18/11/2019 19:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 25 15.28 518 198 0.20 / 135.19 2 3
2 7 2006.68 32 15.14 2908 1409 1.61 / 136.60 2 3
3 13 1571.96 17 15.16 2397 618 2.22 / 137.22 2 3
4 13 1013.48 17 15.22 1701 440 2.66 / 137.66 2 4
5 13 582.36 17 15.27 1154 300 2.96 / 137.96 2 5
6 13 63.16 17 15.38 460 120 3.08 / 138.08 2 6
7 8 -0.12 175 15.34 357 958 4.04 / 139.04 2 18
Average= 3.86
(KJ/cycle)

Cycle 34 GMT 8/11/2019 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 25 15.30 510 195 0.20 / 131.19 2 3
2 7 2001.96 32 15.14 2906 1408 1.60 / 132.60 2 3
3 13 1566.76 17 15.16 2387 615 2.22 / 133.21 2 4
4 13 988.08 17 15.22 1678 434 2.65 / 133.65 2 5
5 13 430.36 17 15.31 960 250 2.90 / 133.90 2 5
6 13 70.64 17 15.38 475 124 3.03 / 134.02 2 6
7 8 0.20 175 15.34 362 972 4.00 / 134.99 2 16
Average= 3.86
(KJ/cycle)

Cycle 33 GMT 29/10/2019 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 26 15.29 510 203 0.20 / 127.16 2 3
2 3 964.00 -2 15.62 6 0 0.00 / 127.16 2 3
3 7 2005.60 32 15.14 2905 1407 1.61 / 128.57 2 4
4 13 1563.00 17 15.17 2389 616 2.23 / 129.19 2 4
5 13 1003.64 17 15.22 1693 438 2.66 / 129.63 2 4
6 13 571.80 17 15.28 1144 297 2.96 / 129.92 2 5
7 13 60.52 17 15.38 456 119 3.08 / 130.04 2 5
8 8 -0.08 175 15.35 355 954 4.03 / 131.00 2 16
Average= 3.85
(KJ/cycle)

Cycle 32 GMT 20/10/2019 1:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 26 15.29 522 208 0.21 / 123.17 2 3
2 7 2003.20 32 15.15 2909 1410 1.62 / 124.58 2 3
3 13 1457.64 17 15.18 2259 583 2.20 / 125.17 2 4
4 13 1044.52 17 15.21 1740 450 2.65 / 125.62 2 4
5 13 476.52 17 15.30 1010 263 2.91 / 125.88 2 4
6 13 44.76 17 15.39 433 113 3.03 / 125.99 2 6
7 8 0.16 175 15.34 361 969 4.00 / 126.96 2 16
Average= 3.85
(KJ/cycle)

Cycle 31 GMT 10/10/2019 3:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 26 15.31 510 203 0.20 / 119.15 2 3
2 7 2004.04 33 15.15 2904 1452 1.65 / 120.61 2 3
3 13 1448.56 17 15.19 2248 581 2.24 / 121.19 2 4
4 13 1028.36 17 15.22 1715 444 2.68 / 121.63 2 5
5 13 463.76 17 15.31 997 259 2.94 / 121.89 2 5
6 13 39.44 17 15.39 424 111 3.05 / 122.00 2 5
7 8 0.40 175 15.35 359 964 4.01 / 122.96 2 15
Average= 3.84
(KJ/cycle)

Cycle 30 GMT 30/ 9/2019 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 27 15.30 526 217 0.22 / 115.24 2 3
2 3 958.48 -2 15.63 6 0 0.00 / 115.24 2 3
3 7 2002.92 32 15.15 2904 1408 1.63 / 116.65 2 3
4 13 1568.28 17 15.17 2395 618 2.24 / 117.27 2 3
5 13 1003.28 17 15.23 1693 438 2.68 / 117.70 2 5
6 13 568.08 17 15.29 1136 295 2.98 / 118.00 2 5
7 8 -0.24 175 15.36 354 952 3.93 / 118.95 2 17
Average= 3.84
(KJ/cycle)

Cycle 29 GMT 20/ 9/2019 6:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 27 15.31 510 211 0.21 / 111.20 2 3
2 3 985.96 -1 15.63 6 0 0.00 / 111.20 2 3
3 7 2002.48 32 15.16 2905 1409 1.62 / 112.61 2 3
4 13 1568.76 17 15.18 2391 617 2.24 / 113.22 2 3
5 13 1000.04 17 15.24 1685 437 2.67 / 113.66 2 5
6 13 569.80 17 15.29 1137 296 2.97 / 113.96 2 5
7 8 0.44 175 15.37 356 958 3.93 / 114.91 2 15
8 14 0.44 20 15.35 356 109 4.04 / 115.02 2 17
Average= 3.83
(KJ/cycle)

Cycle 28 GMT 10/ 9/2019 8:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 28 15.31 501 215 0.21 / 107.19 2 3
2 3 951.16 -2 15.64 7 0 0.00 / 107.19 2 3
3 3 987.12 -1 15.66 7 0 0.00 / 107.19 2 3
4 7 2002.12 33 15.15 2898 1449 1.66 / 108.64 2 3
5 13 1565.24 17 15.18 2382 615 2.28 / 109.26 2 4
6 13 990.12 17 15.24 1672 433 2.71 / 109.69 2 4
7 13 453.28 17 15.32 974 254 2.97 / 109.94 2 5
8 13 37.60 17 15.40 416 109 3.07 / 110.05 2 5
9 8 0.04 175 15.36 348 935 4.01 / 110.99 2 18
Average= 3.83
(KJ/cycle)

Cycle 27 GMT 31/ 8/2019 10:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 27 15.32 500 207 0.21 / 103.11 2 3
2 10 1023.48 2 15.29 1780 54 0.26 / 103.17 2 3
3 7 2003.08 32 15.17 2905 1410 1.67 / 104.58 2 3
4 13 1581.88 17 15.18 2401 620 2.29 / 105.20 2 3
5 13 1023.60 17 15.24 1711 443 2.73 / 105.64 2 5
6 13 584.76 17 15.30 1145 298 3.03 / 105.94 2 6
7 13 71.96 17 15.40 453 119 3.15 / 106.06 2 5
8 8 0.08 175 15.37 342 920 4.07 / 106.98 2 16
Average= 3.82
(KJ/cycle)

Cycle 26 GMT 21/ 8/2019 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 27 15.32 490 203 0.20 / 99.14 2 3
2 7 2003.96 33 15.16 2894 1448 1.65 / 100.58 2 4
3 13 1470.40 17 15.20 2257 583 2.23 / 101.17 2 3
4 13 1055.64 17 15.23 1746 452 2.69 / 101.62 2 5
5 13 496.32 17 15.32 1022 266 2.95 / 101.89 2 5
6 13 21.16 17 15.41 388 102 3.05 / 101.99 2 5
7 8 0.56 175 15.37 342 920 3.97 / 102.91 2 18
Average= 3.81
(KJ/cycle)

Cycle 25 GMT 11/ 8/2019 13:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 28 15.33 483 207 0.21 / 95.11 2 3
2 3 984.28 -1 15.64 6 0 0.00 / 95.11 2 3
3 7 2004.16 32 15.17 2894 1405 1.61 / 96.52 2 3
4 13 1578.48 17 15.19 2397 619 2.23 / 97.13 2 4
5 13 1146.08 17 15.23 1865 483 2.71 / 97.62 2 4
6 13 566.68 17 15.31 1121 292 3.01 / 97.91 2 4
7 13 60.20 17 15.41 436 114 3.12 / 98.02 2 5
8 8 -0.12 175 15.38 338 910 4.03 / 98.93 2 17
Average= 3.81
(KJ/cycle)

Cycle 24 GMT 1/ 8/2019 15:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 29 15.34 482 214 0.21 / 91.06 2 3
2 3 946.88 -2 15.65 6 0 0.00 / 91.06 2 3
3 7 2002.88 32 15.17 2902 1409 1.62 / 92.47 2 3
4 13 1588.48 17 15.19 2404 621 2.24 / 93.09 2 3
5 13 1028.80 17 15.25 1716 445 2.69 / 93.54 2 5
6 13 594.28 17 15.31 1159 302 2.99 / 93.84 2 5
7 13 148.08 17 15.39 557 146 3.14 / 93.98 2 6
8 8 -0.32 175 15.38 342 920 4.06 / 94.90 2 15
Average= 3.80
(KJ/cycle)

Cycle 23 GMT 22/ 7/2019 17:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 26 15.34 501 200 0.20 / 87.10 2 3
2 10 1011.68 3 15.30 1757 81 0.28 / 87.18 2 3
3 3 1018.28 1 15.39 1769 27 0.31 / 87.21 2 4
4 7 2002.92 32 15.18 2892 1405 1.71 / 88.61 2 3
5 13 1443.52 17 15.21 2228 576 2.29 / 89.19 2 3
6 13 1028.08 17 15.25 1715 445 2.73 / 89.63 2 4
7 13 588.92 17 15.31 1151 300 3.03 / 89.93 2 5
8 8 0.28 175 15.39 340 916 3.95 / 90.85 2 14
Average= 3.79
(KJ/cycle)

Cycle 22 GMT 12/ 7/2019 19:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 26 15.34 487 194 0.19 / 83.19 2 3
2 3 1030.92 1 15.36 1792 28 0.22 / 83.21 2 4
3 7 2003.12 32 15.18 2888 1403 1.62 / 84.62 2 3
4 13 1599.76 17 15.20 2422 626 2.25 / 85.24 2 3
5 13 1041.72 17 15.25 1727 448 2.70 / 85.69 2 5
6 13 614.28 17 15.31 1180 307 3.01 / 86.00 2 5
7 8 0.08 175 15.40 334 900 3.91 / 86.90 2 15
Average= 3.78
(KJ/cycle)

Cycle 21 GMT 2/ 7/2019 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 26 15.34 503 201 0.20 / 79.31 2 3
2 7 2001.60 32 15.18 2893 1405 1.61 / 80.71 2 3
3 13 1444.04 17 15.22 2224 575 2.18 / 81.29 2 4
4 13 921.00 17 15.27 1572 408 2.59 / 81.70 2 6
5 13 500.84 17 15.33 1032 269 2.86 / 81.96 2 5
6 13 56.72 17 15.42 431 113 2.97 / 82.08 2 5
7 8 0.48 175 15.39 340 916 3.89 / 82.99 2 18
Average= 3.77
(KJ/cycle)

Cycle 20 GMT 22/ 6/2019 22:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 26 15.34 496 198 0.20 / 75.32 2 3
2 3 980.04 -1 15.66 6 0 0.00 / 75.32 2 3
3 7 2006.96 32 15.18 2894 1406 1.60 / 76.73 2 3
4 13 1574.44 17 15.21 2395 619 2.22 / 77.35 2 4
5 13 1002.60 17 15.26 1685 437 2.66 / 77.78 2 5
6 13 565.52 17 15.33 1115 291 2.95 / 78.07 2 5
7 8 -0.24 175 15.40 344 927 3.88 / 79.00 2 10
8 14 -0.24 20 15.38 343 106 3.98 / 79.11 3 17
Average= 3.77
(KJ/cycle)

Cycle 19 GMT 13/ 6/2019 0:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 26 15.35 496 198 0.20 / 71.24 2 3
2 7 2003.68 32 15.19 2888 1404 1.60 / 72.64 2 3
3 13 1567.68 17 15.22 2366 612 2.21 / 73.25 2 4
4 13 996.20 17 15.27 1673 434 2.65 / 73.69 2 5
5 13 568.24 17 15.33 1119 292 2.94 / 73.98 2 6
6 13 61.60 17 15.43 441 116 3.06 / 74.09 2 6
7 8 0.28 175 15.39 343 924 3.98 / 75.02 2 17
8 14 0.28 20 15.37 344 106 4.09 / 75.12 3 19
Average= 3.76
(KJ/cycle)

Cycle 18 GMT 3/ 6/2019 2:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 27 15.34 492 204 0.20 / 67.41 2 3
2 3 954.76 -2 15.67 6 0 0.00 / 67.41 2 3
3 7 2006.00 32 15.20 2901 1411 1.61 / 68.82 2 3
4 13 1469.80 17 15.23 2249 582 2.20 / 69.40 2 4
5 13 1052.80 17 15.26 1740 451 2.65 / 69.85 2 5
6 13 492.60 17 15.35 1023 267 2.92 / 70.12 2 5
7 8 0.08 175 15.40 341 919 3.83 / 71.04 2 12
Average= 3.74
(KJ/cycle)

Cycle 17 GMT 24/ 5/2019 3:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 27 15.35 504 209 0.21 / 63.42 2 3
2 7 2017.60 32 15.20 2906 1413 1.62 / 64.83 2 3
3 13 1594.00 17 15.22 2399 621 2.24 / 65.45 2 4
4 13 1004.20 17 15.28 1679 436 2.68 / 65.89 2 5
5 13 461.00 17 15.35 982 256 2.94 / 66.15 2 5
6 13 101.12 17 15.42 494 129 3.06 / 66.28 2 6
7 8 0.40 175 15.40 344 927 3.99 / 67.20 2 15
Average= 3.73
(KJ/cycle)

Cycle 16 GMT 14/ 5/2019 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 26 15.35 497 198 0.20 / 59.38 2 3
2 3 1023.00 1 15.40 1804 28 0.23 / 59.40 2 6
3 7 2006.88 32 15.20 2902 1412 1.64 / 60.81 2 3
4 13 1595.28 17 15.22 2415 625 2.26 / 61.44 2 4
5 13 1042.96 17 15.27 1726 448 2.71 / 61.89 2 5
6 13 484.40 17 15.35 1020 266 2.98 / 62.15 2 6
7 13 96.92 17 15.42 498 131 3.11 / 62.28 2 6
8 8 -0.08 175 15.40 344 927 4.03 / 63.21 2 16
Average= 3.72
(KJ/cycle)

Cycle 15 GMT 4/ 5/2019 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 26 15.36 491 196 0.20 / 55.33 2 3
2 7 2003.20 32 15.20 2896 1409 1.60 / 56.74 2 3
3 13 1458.72 17 15.25 2247 583 2.19 / 57.32 2 4
4 13 1036.08 17 15.27 1725 448 2.64 / 57.77 2 5
5 13 462.00 17 15.36 986 257 2.89 / 58.02 2 5
6 13 77.84 17 15.43 463 121 3.01 / 58.14 2 7
7 8 0.08 175 15.40 344 927 3.94 / 59.07 2 13
8 14 0.08 20 15.38 343 106 4.05 / 59.18 4 16
Average= 3.70
(KJ/cycle)

Cycle 14 GMT 24/ 4/2019 8:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 26 15.36 497 198 0.20 / 51.24 2 3
2 7 2006.40 32 15.21 2906 1414 1.61 / 52.66 2 3
3 13 1565.48 17 15.23 2380 616 2.23 / 53.27 2 4
4 13 996.16 17 15.28 1677 436 2.66 / 53.71 2 5
5 13 563.96 17 15.34 1126 294 2.96 / 54.00 2 5
6 13 31.28 17 15.45 399 105 3.06 / 54.11 2 5
7 8 -0.08 175 15.41 340 917 3.98 / 55.03 2 17
8 14 -0.08 20 15.39 340 105 4.08 / 55.13 3 16
Average= 3.68
(KJ/cycle)

Cycle 13 GMT 14/ 4/2019 10:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 26 15.36 487 194 0.19 / 47.30 2 3
2 7 2003.52 32 15.21 2893 1408 1.60 / 48.71 2 3
3 13 1565.32 17 15.23 2376 615 2.22 / 49.33 2 4
4 13 989.28 17 15.29 1657 431 2.65 / 49.76 2 6
5 13 435.96 17 15.37 953 249 2.90 / 50.01 2 5
6 13 71.28 17 15.44 453 119 3.02 / 50.13 2 6
7 8 0.04 175 15.41 341 920 3.94 / 51.05 2 12
Average= 3.65
(KJ/cycle)

Cycle 12 GMT 4/ 4/2019 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 26 15.37 498 199 0.20 / 43.21 2 3
2 3 988.16 -1 15.68 7 0 0.00 / 43.21 2 3
3 7 2002.32 32 15.21 2895 1409 1.61 / 44.62 2 4
4 13 1576.48 17 15.24 2388 619 2.23 / 45.24 2 4
5 13 995.52 17 15.29 1675 435 2.66 / 45.67 2 5
6 13 565.44 17 15.34 1122 293 2.95 / 45.96 2 5
7 13 58.00 17 15.44 441 116 3.07 / 46.08 2 5
8 8 0.20 175 15.42 343 926 4.00 / 47.00 2 14
9 14 0.20 20 15.40 341 105 4.10 / 47.11 2 16
Average= 3.62
(KJ/cycle)

Cycle 11 GMT 25/ 3/2019 13:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 26 15.37 481 192 0.19 / 39.21 2 3
2 7 2002.64 32 15.21 2898 1411 1.60 / 40.62 2 3
3 13 1573.16 17 15.24 2394 620 2.22 / 41.24 2 4
4 13 997.76 17 15.29 1688 439 2.66 / 41.68 2 5
5 13 560.28 17 15.35 1115 291 2.95 / 41.97 2 7
6 13 58.12 17 15.45 438 115 3.07 / 42.09 2 6
7 8 0.04 175 15.42 342 923 3.99 / 43.01 2 14
Average= 3.58
(KJ/cycle)

Cycle 10 GMT 15/ 3/2019 15:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 26 15.38 478 191 0.19 / 35.27 2 3
2 7 2003.36 32 15.22 2901 1413 1.60 / 36.69 2 3
3 13 1455.56 17 15.25 2253 584 2.19 / 37.27 2 4
4 13 1038.64 17 15.28 1727 449 2.64 / 37.72 2 5
5 13 469.64 17 15.37 1007 263 2.90 / 37.98 2 5
6 13 40.36 17 15.45 410 108 3.01 / 38.09 2 6
7 8 0.08 175 15.41 344 928 3.94 / 39.02 2 15
Average= 3.55
(KJ/cycle)

Cycle 9 GMT 5/ 3/2019 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 26 15.38 485 194 0.19 / 31.36 2 3
2 7 2002.64 31 15.24 2904 1372 1.57 / 32.73 2 3
3 13 1575.12 17 15.25 2391 620 2.19 / 33.35 2 3
4 13 997.88 17 15.30 1681 437 2.62 / 33.79 2 5
5 13 569.48 17 15.35 1125 294 2.92 / 34.08 2 5
6 13 29.52 17 15.46 397 104 3.02 / 34.19 2 6
7 8 0.16 170 15.42 341 894 3.91 / 35.08 2 15
Average= 3.51
(KJ/cycle)

Cycle 8 GMT 23/ 2/2019 18:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 26 15.38 479 192 0.19 / 27.52 2 3
2 3 1019.92 1 15.43 1791 28 0.22 / 27.55 2 4
3 7 2003.40 31 15.24 2906 1373 1.59 / 28.92 2 3
4 13 1570.80 17 15.25 2387 619 2.21 / 29.54 2 3
5 13 1007.48 17 15.30 1676 436 2.65 / 29.98 2 4
6 13 580.56 17 15.36 1138 297 2.94 / 30.28 2 5
7 8 0.12 170 15.43 340 892 3.84 / 31.17 2 10
Average= 3.46
(KJ/cycle)

Cycle 7 GMT 13/ 2/2019 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 27 15.37 491 204 0.20 / 23.59 2 3
2 3 962.80 -2 15.69 6 0 0.00 / 23.59 2 3
3 7 2003.48 31 15.24 2896 1368 1.57 / 24.96 2 4
4 13 1588.00 17 15.25 2401 622 2.19 / 25.58 2 4
5 13 1131.28 17 15.29 1840 478 2.67 / 26.06 2 4
6 13 536.04 17 15.37 1077 281 2.95 / 26.34 2 6
7 13 54.04 17 15.46 424 111 3.07 / 26.45 2 5
8 8 0.20 170 15.43 335 879 3.94 / 27.33 2 12
Average= 3.42
(KJ/cycle)

Cycle 6 GMT 3/ 2/2019 21:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 27 15.38 481 200 0.20 / 19.67 2 3
2 7 2002.20 39 15.20 2884 1710 1.91 / 21.38 2 3
3 13 1258.88 17 15.29 1997 519 2.43 / 21.89 2 4
4 13 844.08 17 15.32 1477 385 2.81 / 22.28 2 5
5 13 393.76 15 15.39 895 207 3.02 / 22.49 2 5
6 8 0.04 170 15.43 344 902 3.92 / 23.39 2 18
Average= 3.34
(KJ/cycle)

Cycle 5 GMT 24/ 1/2019 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 29 15.38 480 214 0.21 / 15.71 2 3
2 3 896.68 -4 15.69 6 0 0.00 / 15.71 2 3
3 7 2002.68 38 15.21 2885 1667 1.88 / 17.38 2 4
4 13 1375.28 17 15.27 2129 553 2.43 / 17.93 2 4
5 13 796.72 17 15.34 1409 367 2.80 / 18.30 2 6
6 13 251.52 11 15.43 703 119 2.92 / 18.42 2 5
7 13 64.88 6 15.47 448 42 2.96 / 18.46 2 5
8 8 0.08 170 15.44 334 877 3.84 / 19.34 2 11
9 14 0.08 25 15.42 335 129 3.97 / 19.47 2 20
Average= 3.24
(KJ/cycle)

Cycle 4 GMT 15/ 1/2019 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 26 15.38 501 200 0.20 / 12.29 2 3
2 3 1042.60 1 15.41 1826 28 0.23 / 12.32 2 4
3 7 1522.64 38 15.27 2297 1333 1.56 / 13.65 2 3
4 13 1255.04 17 15.28 1979 514 2.08 / 14.17 2 3
5 13 810.72 17 15.32 1434 373 2.45 / 14.54 2 5
6 13 215.00 10 15.43 653 101 2.55 / 14.64 2 5
7 8 0.16 165 15.43 336 855 3.41 / 15.50 2 12
Average= 3.10
(KJ/cycle)

Cycle 3 GMT 14/ 1/2019 1:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 24 15.39 485 179 0.18 / 8.92 2 3
2 10 1027.56 2 15.35 1778 55 0.23 / 8.98 2 3
3 7 1524.40 38 15.27 2299 1334 1.57 / 10.31 2 4
4 13 1248.84 17 15.29 1976 514 2.08 / 10.83 2 4
5 13 677.32 17 15.35 1257 328 2.41 / 11.15 2 4
6 13 115.80 7 15.46 516 56 2.47 / 11.21 2 4
7 13 43.40 5 15.47 411 32 2.50 / 11.24 2 4
8 8 0.12 165 15.43 334 850 3.35 / 12.09 2 14
Average= 3.02
(KJ/cycle)

Cycle 2 GMT 13/ 1/2019 3:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 32 15.42 478 236 0.24 / 5.25 2 3
2 3 837.20 -3 15.72 6 0 0.00 / 5.25 2 3
3 3 906.84 -2 15.74 6 0 0.00 / 5.25 2 3
4 7 1525.20 74 15.20 2280 2565 2.80 / 7.81 2 4
5 13 164.96 9 15.45 583 81 2.88 / 7.89 2 4
6 8 0.16 165 15.44 334 851 3.73 / 8.74 2 14
Average= 2.91
(KJ/cycle)

Cycle 1 GMT 12/ 1/2019 4:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 27 15.63 451 190 0.19 / 1.95 2 2
2 3 969.48 -1 15.75 6 0 0.00 / 1.95 2 2
3 7 990.44 74 15.36 1606 1825 2.02 / 3.77 2 5
4 8 0.24 165 15.51 336 860 2.88 / 4.63 2 20
5 14 0.24 75 15.47 329 382 3.26 / 5.01 3 21
Average= 2.51
(KJ/cycle)

Cycle 0 GMT 11/ 1/2019 18: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.40 27 15.76 460 196 0.20 / 0.20 2 2
2 7 134.20 74 15.73 456 531 0.73 / 0.73 2 3
3 8 0.20 240 15.70 273 1029 1.76 / 1.76 2 14
Average= 1.76