SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.76 | 36 | 14.97 | 417 | 225 | 0.22 / 1005.80 | 2 | 2 |
2 | 12 | 1169.36 | 5 | 15.15 | 1834 | 139 | 0.36 / 1005.94 | 2 | 2 |
3 | 7 | 2002.04 | 34 | 14.77 | 2751 | 1381 | 1.75 / 1007.32 | 2 | 3 |
4 | 13 | 1592.08 | 22 | 14.75 | 2305 | 748 | 2.49 / 1008.07 | 2 | 3 |
5 | 13 | 894.84 | 22 | 14.81 | 1486 | 484 | 2.98 / 1008.55 | 2 | 3 |
6 | 13 | 328.16 | 22 | 14.94 | 780 | 256 | 3.23 / 1008.81 | 2 | 3 |
7 | 13 | 87.64 | 22 | 15.00 | 454 | 150 | 3.38 / 1008.96 | 2 | 3 |
8 | 13 | 47.84 | 22 | 15.00 | 402 | 133 | 3.52 / 1009.09 | 2 | 3 |
9 | 8 | 0.12 | 175 | 14.98 | 308 | 807 | 4.32 / 1009.90 | 2 | 9 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 36 | 14.97 | 407 | 219 | 0.22 / 1001.52 | 2 | 2 |
2 | 12 | 1166.04 | 5 | 15.15 | 1839 | 139 | 0.36 / 1001.65 | 2 | 2 |
3 | 7 | 2003.60 | 34 | 14.77 | 2747 | 1379 | 1.74 / 1003.03 | 2 | 2 |
4 | 13 | 1605.76 | 22 | 14.75 | 2303 | 747 | 2.49 / 1003.78 | 2 | 3 |
5 | 13 | 1015.96 | 22 | 14.79 | 1621 | 527 | 3.01 / 1004.31 | 2 | 3 |
6 | 13 | 286.60 | 22 | 14.96 | 714 | 235 | 3.25 / 1004.54 | 2 | 3 |
7 | 13 | 92.52 | 22 | 15.01 | 428 | 141 | 3.39 / 1004.69 | 2 | 2 |
8 | 13 | 53.08 | 22 | 15.02 | 369 | 122 | 3.51 / 1004.81 | 2 | 2 |
9 | 8 | 0.00 | 175 | 14.99 | 293 | 769 | 4.28 / 1005.58 | 2 | 9 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 36 | 14.98 | 419 | 226 | 0.23 / 997.29 | 2 | 2 |
2 | 12 | 1168.56 | 5 | 15.16 | 1834 | 139 | 0.36 / 997.43 | 2 | 2 |
3 | 7 | 2003.76 | 34 | 14.77 | 2720 | 1366 | 1.73 / 998.80 | 2 | 3 |
4 | 13 | 1466.52 | 22 | 14.78 | 2142 | 696 | 2.43 / 999.49 | 2 | 2 |
5 | 13 | 1055.20 | 22 | 14.79 | 1653 | 538 | 2.97 / 1000.03 | 2 | 3 |
6 | 13 | 307.60 | 22 | 14.95 | 738 | 243 | 3.21 / 1000.28 | 2 | 3 |
7 | 13 | 103.04 | 22 | 15.01 | 438 | 145 | 3.35 / 1000.42 | 2 | 3 |
8 | 13 | 57.40 | 22 | 15.01 | 373 | 123 | 3.48 / 1000.54 | 2 | 3 |
9 | 8 | 0.00 | 175 | 14.99 | 287 | 753 | 4.23 / 1001.30 | 2 | 11 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 36 | 14.97 | 424 | 229 | 0.23 / 993.03 | 2 | 2 |
2 | 12 | 1187.60 | 5 | 15.14 | 1846 | 140 | 0.37 / 993.17 | 2 | 2 |
3 | 7 | 2003.64 | 34 | 14.77 | 2746 | 1379 | 1.75 / 994.55 | 2 | 3 |
4 | 13 | 1586.76 | 22 | 14.76 | 2288 | 743 | 2.49 / 995.29 | 2 | 2 |
5 | 13 | 881.76 | 22 | 14.82 | 1457 | 475 | 2.97 / 995.76 | 2 | 3 |
6 | 13 | 296.44 | 22 | 14.95 | 735 | 242 | 3.21 / 996.01 | 2 | 3 |
7 | 13 | 102.68 | 22 | 15.01 | 450 | 149 | 3.36 / 996.15 | 2 | 2 |
8 | 13 | 55.12 | 22 | 15.01 | 382 | 126 | 3.48 / 996.28 | 2 | 3 |
9 | 8 | 0.12 | 175 | 14.99 | 300 | 787 | 4.27 / 997.07 | 2 | 10 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.80 | 36 | 14.98 | 421 | 227 | 0.23 / 988.65 | 2 | 2 |
2 | 12 | 1171.80 | 5 | 15.14 | 1859 | 141 | 0.37 / 988.79 | 2 | 2 |
3 | 7 | 2004.72 | 34 | 14.76 | 2742 | 1376 | 1.74 / 990.17 | 2 | 3 |
4 | 13 | 1600.60 | 22 | 14.75 | 2298 | 746 | 2.49 / 990.91 | 2 | 2 |
5 | 13 | 1148.28 | 22 | 14.77 | 1768 | 574 | 3.06 / 991.49 | 2 | 3 |
6 | 13 | 384.72 | 22 | 14.92 | 839 | 275 | 3.34 / 991.76 | 2 | 3 |
7 | 13 | 115.64 | 22 | 15.00 | 469 | 155 | 3.49 / 991.92 | 2 | 2 |
8 | 13 | 37.96 | 22 | 15.02 | 352 | 116 | 3.61 / 992.04 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 291 | 763 | 4.37 / 992.80 | 2 | 12 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 36 | 14.96 | 428 | 231 | 0.23 / 984.41 | 2 | 2 |
2 | 12 | 1163.64 | 5 | 15.15 | 1836 | 139 | 0.37 / 984.55 | 2 | 2 |
3 | 7 | 2004.12 | 34 | 14.76 | 2748 | 1379 | 1.75 / 985.92 | 2 | 2 |
4 | 13 | 1593.28 | 22 | 14.76 | 2284 | 742 | 2.49 / 986.67 | 2 | 2 |
5 | 13 | 993.36 | 22 | 14.80 | 1589 | 517 | 3.01 / 987.18 | 2 | 3 |
6 | 13 | 263.16 | 22 | 14.96 | 681 | 224 | 3.23 / 987.41 | 2 | 2 |
7 | 13 | 87.92 | 22 | 15.01 | 428 | 141 | 3.37 / 987.55 | 2 | 3 |
8 | 13 | 27.04 | 22 | 15.02 | 348 | 115 | 3.49 / 987.66 | 2 | 2 |
9 | 8 | 0.12 | 175 | 15.00 | 290 | 761 | 4.25 / 988.42 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 36 | 14.96 | 420 | 226 | 0.23 / 980.02 | 2 | 2 |
2 | 12 | 1159.64 | 5 | 15.14 | 1830 | 139 | 0.36 / 980.16 | 2 | 2 |
3 | 7 | 2002.96 | 34 | 14.76 | 2739 | 1375 | 1.74 / 981.53 | 2 | 2 |
4 | 13 | 1732.40 | 22 | 14.75 | 2440 | 792 | 2.53 / 982.33 | 2 | 3 |
5 | 13 | 979.08 | 22 | 14.80 | 1569 | 511 | 3.04 / 982.84 | 2 | 3 |
6 | 13 | 372.20 | 22 | 14.93 | 839 | 276 | 3.32 / 983.11 | 2 | 3 |
7 | 13 | 109.88 | 22 | 15.00 | 473 | 156 | 3.47 / 983.27 | 2 | 3 |
8 | 13 | 33.64 | 22 | 15.02 | 358 | 118 | 3.59 / 983.39 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 301 | 790 | 4.38 / 984.18 | 2 | 8 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 36 | 14.97 | 425 | 229 | 0.23 / 975.80 | 2 | 2 |
2 | 12 | 1195.64 | 5 | 15.15 | 1845 | 140 | 0.37 / 975.94 | 2 | 2 |
3 | 7 | 2002.60 | 34 | 14.77 | 2742 | 1377 | 1.75 / 977.32 | 2 | 3 |
4 | 13 | 1446.92 | 22 | 14.78 | 2120 | 689 | 2.44 / 978.01 | 2 | 3 |
5 | 13 | 880.40 | 22 | 14.81 | 1472 | 480 | 2.91 / 978.49 | 2 | 3 |
6 | 13 | 309.88 | 22 | 14.94 | 763 | 251 | 3.17 / 978.74 | 2 | 3 |
7 | 13 | 87.76 | 22 | 15.01 | 428 | 141 | 3.31 / 978.88 | 2 | 3 |
8 | 13 | 49.64 | 22 | 15.01 | 387 | 128 | 3.43 / 979.01 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.98 | 299 | 784 | 4.22 / 979.79 | 2 | 8 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 36 | 14.98 | 412 | 222 | 0.22 / 971.77 | 2 | 2 |
2 | 12 | 1169.92 | 5 | 15.16 | 1830 | 139 | 0.36 / 971.91 | 2 | 2 |
3 | 7 | 1742.56 | 34 | 14.84 | 2455 | 1239 | 1.60 / 973.15 | 2 | 3 |
4 | 13 | 1626.20 | 22 | 14.80 | 2334 | 760 | 2.36 / 973.91 | 2 | 3 |
5 | 13 | 890.44 | 22 | 14.86 | 1465 | 479 | 2.84 / 974.39 | 2 | 3 |
6 | 13 | 315.60 | 22 | 14.96 | 765 | 252 | 3.09 / 974.64 | 2 | 3 |
7 | 13 | 92.52 | 22 | 15.01 | 452 | 149 | 3.24 / 974.79 | 2 | 3 |
8 | 8 | 0.20 | 175 | 15.00 | 299 | 785 | 4.02 / 975.58 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 36 | 14.97 | 419 | 226 | 0.23 / 967.55 | 2 | 2 |
2 | 12 | 1187.72 | 5 | 15.15 | 1850 | 140 | 0.37 / 967.69 | 2 | 2 |
3 | 7 | 2003.44 | 34 | 14.76 | 2746 | 1378 | 1.74 / 969.06 | 2 | 3 |
4 | 13 | 1575.32 | 22 | 14.76 | 2272 | 738 | 2.48 / 969.80 | 2 | 3 |
5 | 13 | 987.60 | 22 | 14.80 | 1578 | 514 | 3.00 / 970.32 | 2 | 3 |
6 | 13 | 275.64 | 22 | 14.96 | 695 | 229 | 3.22 / 970.54 | 2 | 3 |
7 | 13 | 81.52 | 22 | 15.02 | 417 | 138 | 3.36 / 970.68 | 2 | 2 |
8 | 13 | 23.76 | 22 | 15.02 | 333 | 110 | 3.47 / 970.79 | 2 | 2 |
9 | 8 | 0.04 | 175 | 15.00 | 289 | 759 | 4.23 / 971.55 | 2 | 10 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 36 | 14.97 | 411 | 221 | 0.22 / 963.27 | 2 | 2 |
2 | 12 | 1188.76 | 5 | 15.15 | 1853 | 140 | 0.36 / 963.41 | 2 | 2 |
3 | 7 | 2003.36 | 34 | 14.77 | 2739 | 1375 | 1.74 / 964.79 | 2 | 2 |
4 | 13 | 1579.72 | 22 | 14.76 | 2285 | 742 | 2.48 / 965.53 | 2 | 3 |
5 | 13 | 1001.28 | 22 | 14.80 | 1614 | 526 | 3.00 / 966.05 | 2 | 3 |
6 | 13 | 276.04 | 22 | 14.96 | 701 | 231 | 3.24 / 966.28 | 2 | 3 |
7 | 13 | 83.56 | 22 | 15.01 | 430 | 142 | 3.38 / 966.43 | 2 | 2 |
8 | 13 | 46.36 | 22 | 15.01 | 371 | 123 | 3.50 / 966.55 | 2 | 2 |
9 | 8 | 0.04 | 175 | 14.99 | 294 | 771 | 4.27 / 967.32 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 36 | 14.98 | 405 | 218 | 0.22 / 959.09 | 2 | 2 |
2 | 12 | 1156.84 | 5 | 15.16 | 1805 | 137 | 0.36 / 959.23 | 2 | 2 |
3 | 7 | 2003.56 | 34 | 14.78 | 2722 | 1368 | 1.72 / 960.60 | 2 | 2 |
4 | 13 | 1472.16 | 22 | 14.78 | 2145 | 697 | 2.42 / 961.30 | 2 | 3 |
5 | 13 | 909.68 | 22 | 14.82 | 1489 | 485 | 2.91 / 961.78 | 2 | 3 |
6 | 13 | 322.28 | 22 | 14.94 | 760 | 250 | 3.16 / 962.03 | 2 | 3 |
7 | 13 | 92.00 | 22 | 15.01 | 435 | 144 | 3.30 / 962.17 | 2 | 2 |
8 | 13 | 22.56 | 22 | 15.02 | 336 | 111 | 3.41 / 962.29 | 2 | 3 |
9 | 8 | 0.08 | 175 | 14.99 | 291 | 763 | 4.17 / 963.05 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 36 | 14.97 | 410 | 221 | 0.22 / 954.88 | 2 | 2 |
2 | 12 | 1160.72 | 5 | 15.16 | 1829 | 139 | 0.36 / 955.02 | 2 | 2 |
3 | 7 | 2004.36 | 34 | 14.77 | 2738 | 1375 | 1.73 / 956.39 | 2 | 2 |
4 | 13 | 1586.64 | 22 | 14.77 | 2274 | 739 | 2.47 / 957.13 | 2 | 3 |
5 | 13 | 995.88 | 22 | 14.80 | 1592 | 518 | 2.99 / 957.65 | 2 | 3 |
6 | 13 | 269.36 | 22 | 14.96 | 688 | 226 | 3.22 / 957.88 | 2 | 3 |
7 | 13 | 82.56 | 22 | 15.01 | 416 | 137 | 3.36 / 958.02 | 2 | 2 |
8 | 13 | 24.56 | 22 | 15.02 | 332 | 110 | 3.47 / 958.13 | 2 | 2 |
9 | 8 | 0.24 | 175 | 14.99 | 286 | 750 | 4.22 / 958.88 | 2 | 7 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 36 | 14.97 | 416 | 224 | 0.22 / 950.59 | 2 | 2 |
2 | 12 | 1157.40 | 5 | 15.16 | 1825 | 138 | 0.36 / 950.73 | 2 | 2 |
3 | 7 | 2006.48 | 34 | 14.77 | 2739 | 1375 | 1.74 / 952.10 | 2 | 2 |
4 | 13 | 1588.80 | 22 | 14.77 | 2282 | 742 | 2.48 / 952.84 | 2 | 2 |
5 | 13 | 1138.12 | 22 | 14.78 | 1760 | 572 | 3.05 / 953.42 | 2 | 3 |
6 | 13 | 257.16 | 22 | 14.97 | 668 | 220 | 3.27 / 953.64 | 2 | 3 |
7 | 13 | 80.20 | 22 | 15.01 | 415 | 137 | 3.41 / 953.77 | 2 | 2 |
8 | 13 | 47.88 | 22 | 15.01 | 372 | 123 | 3.53 / 953.90 | 2 | 2 |
9 | 8 | 0.00 | 175 | 14.99 | 291 | 763 | 4.30 / 954.66 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.24 | 36 | 14.96 | 424 | 228 | 0.23 / 946.31 | 2 | 2 |
2 | 12 | 1180.44 | 5 | 15.15 | 1852 | 140 | 0.37 / 946.45 | 2 | 2 |
3 | 7 | 2003.32 | 34 | 14.77 | 2756 | 1384 | 1.75 / 947.83 | 2 | 2 |
4 | 13 | 1590.60 | 22 | 14.76 | 2296 | 746 | 2.50 / 948.58 | 2 | 3 |
5 | 13 | 998.60 | 22 | 14.80 | 1602 | 522 | 3.02 / 949.10 | 2 | 3 |
6 | 13 | 281.80 | 22 | 14.96 | 710 | 234 | 3.25 / 949.33 | 2 | 3 |
7 | 13 | 92.64 | 22 | 15.01 | 444 | 147 | 3.40 / 949.48 | 2 | 2 |
8 | 13 | 32.84 | 22 | 15.02 | 361 | 119 | 3.52 / 949.60 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.99 | 292 | 766 | 4.29 / 950.36 | 2 | 7 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 36 | 14.97 | 416 | 224 | 0.22 / 941.91 | 2 | 2 |
2 | 12 | 1177.36 | 5 | 15.14 | 1867 | 141 | 0.37 / 942.05 | 2 | 2 |
3 | 7 | 2004.16 | 35 | 14.77 | 2747 | 1420 | 1.79 / 943.47 | 2 | 3 |
4 | 13 | 1588.12 | 22 | 14.76 | 2296 | 746 | 2.53 / 944.22 | 2 | 3 |
5 | 13 | 972.16 | 22 | 14.81 | 1568 | 511 | 3.04 / 944.73 | 2 | 3 |
6 | 13 | 504.12 | 22 | 14.88 | 1014 | 332 | 3.37 / 945.06 | 2 | 3 |
7 | 13 | 100.08 | 22 | 15.00 | 446 | 147 | 3.52 / 945.21 | 2 | 3 |
8 | 13 | 32.04 | 22 | 15.02 | 345 | 114 | 3.64 / 945.32 | 2 | 2 |
9 | 8 | 0.04 | 175 | 14.99 | 289 | 758 | 4.39 / 946.08 | 2 | 10 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.44 | 36 | 14.97 | 407 | 219 | 0.22 / 937.68 | 2 | 2 |
2 | 12 | 1166.20 | 5 | 15.16 | 1842 | 140 | 0.36 / 937.82 | 2 | 2 |
3 | 7 | 2007.32 | 34 | 14.78 | 2752 | 1383 | 1.74 / 939.20 | 2 | 3 |
4 | 13 | 1484.76 | 22 | 14.78 | 2170 | 706 | 2.45 / 939.91 | 2 | 3 |
5 | 13 | 925.36 | 22 | 14.81 | 1506 | 491 | 2.94 / 940.40 | 2 | 3 |
6 | 13 | 327.72 | 22 | 14.94 | 767 | 252 | 3.19 / 940.65 | 2 | 3 |
7 | 13 | 106.64 | 22 | 15.00 | 460 | 152 | 3.34 / 940.80 | 2 | 3 |
8 | 13 | 28.60 | 22 | 15.01 | 354 | 117 | 3.46 / 940.92 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.99 | 293 | 769 | 4.23 / 941.69 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 36 | 14.96 | 432 | 233 | 0.23 / 933.47 | 2 | 2 |
2 | 12 | 1164.92 | 5 | 15.16 | 1840 | 139 | 0.37 / 933.61 | 2 | 2 |
3 | 7 | 2007.28 | 34 | 14.78 | 2744 | 1379 | 1.75 / 934.98 | 2 | 2 |
4 | 13 | 1588.64 | 22 | 14.77 | 2289 | 744 | 2.49 / 935.73 | 2 | 3 |
5 | 13 | 883.68 | 22 | 14.82 | 1455 | 474 | 2.97 / 936.20 | 2 | 3 |
6 | 13 | 313.84 | 22 | 14.94 | 752 | 247 | 3.22 / 936.45 | 2 | 3 |
7 | 13 | 101.08 | 22 | 15.01 | 444 | 147 | 3.36 / 936.60 | 2 | 2 |
8 | 13 | 29.08 | 22 | 15.02 | 337 | 111 | 3.47 / 936.71 | 2 | 2 |
9 | 8 | 0.20 | 175 | 14.99 | 286 | 750 | 4.22 / 937.46 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 36 | 14.97 | 427 | 230 | 0.23 / 929.14 | 2 | 2 |
2 | 12 | 1156.36 | 5 | 15.16 | 1822 | 138 | 0.37 / 929.28 | 2 | 2 |
3 | 7 | 2002.04 | 35 | 14.76 | 2748 | 1420 | 1.79 / 930.70 | 2 | 3 |
4 | 13 | 1575.68 | 22 | 14.76 | 2277 | 739 | 2.53 / 931.44 | 2 | 3 |
5 | 13 | 847.72 | 22 | 14.83 | 1423 | 464 | 2.99 / 931.90 | 2 | 3 |
6 | 13 | 384.20 | 22 | 14.92 | 858 | 282 | 3.27 / 932.18 | 2 | 3 |
7 | 13 | 112.40 | 22 | 14.99 | 468 | 154 | 3.43 / 932.34 | 2 | 2 |
8 | 13 | 32.28 | 22 | 15.01 | 354 | 117 | 3.54 / 932.45 | 2 | 2 |
9 | 8 | 0.16 | 175 | 14.98 | 298 | 781 | 4.33 / 933.23 | 2 | 10 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.68 | 36 | 14.97 | 422 | 227 | 0.23 / 924.91 | 2 | 2 |
2 | 12 | 1168.80 | 5 | 15.15 | 1854 | 140 | 0.37 / 925.05 | 2 | 2 |
3 | 7 | 2002.56 | 34 | 14.77 | 2748 | 1380 | 1.75 / 926.43 | 2 | 3 |
4 | 13 | 1466.16 | 22 | 14.78 | 2150 | 699 | 2.45 / 927.13 | 2 | 4 |
5 | 13 | 893.76 | 22 | 14.82 | 1477 | 482 | 2.93 / 927.61 | 2 | 3 |
6 | 13 | 312.00 | 22 | 14.94 | 772 | 254 | 3.18 / 927.86 | 2 | 3 |
7 | 13 | 105.60 | 22 | 15.00 | 456 | 150 | 3.33 / 928.01 | 2 | 3 |
8 | 13 | 56.48 | 22 | 15.00 | 379 | 125 | 3.46 / 928.14 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 293 | 769 | 4.23 / 928.91 | 2 | 8 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 36 | 14.97 | 418 | 225 | 0.23 / 920.67 | 2 | 2 |
2 | 12 | 1165.60 | 5 | 15.16 | 1824 | 138 | 0.36 / 920.81 | 2 | 2 |
3 | 7 | 2005.92 | 34 | 14.78 | 2738 | 1376 | 1.74 / 922.18 | 2 | 2 |
4 | 13 | 1586.08 | 22 | 14.77 | 2286 | 743 | 2.48 / 922.92 | 2 | 2 |
5 | 13 | 1001.04 | 22 | 14.80 | 1598 | 520 | 3.00 / 923.44 | 2 | 3 |
6 | 13 | 274.52 | 22 | 14.96 | 705 | 232 | 3.23 / 923.68 | 2 | 3 |
7 | 13 | 99.16 | 22 | 15.01 | 435 | 144 | 3.38 / 923.82 | 2 | 2 |
8 | 13 | 34.92 | 22 | 15.02 | 344 | 114 | 3.49 / 923.93 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.99 | 285 | 748 | 4.24 / 924.68 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.16 | 36 | 14.96 | 422 | 227 | 0.23 / 916.41 | 2 | 2 |
2 | 12 | 1178.84 | 5 | 15.16 | 1844 | 140 | 0.37 / 916.55 | 2 | 2 |
3 | 7 | 2005.28 | 35 | 14.77 | 2742 | 1417 | 1.78 / 917.97 | 2 | 3 |
4 | 13 | 1580.04 | 22 | 14.77 | 2277 | 740 | 2.52 / 918.71 | 2 | 2 |
5 | 13 | 865.72 | 22 | 14.83 | 1439 | 469 | 2.99 / 919.18 | 2 | 3 |
6 | 13 | 286.56 | 22 | 14.95 | 724 | 238 | 3.23 / 919.42 | 2 | 3 |
7 | 13 | 108.00 | 22 | 15.00 | 450 | 148 | 3.38 / 919.57 | 2 | 2 |
8 | 13 | 57.48 | 22 | 15.01 | 376 | 124 | 3.50 / 919.69 | 2 | 2 |
9 | 8 | 0.16 | 175 | 14.99 | 286 | 750 | 4.25 / 920.44 | 2 | 8 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.44 | 36 | 14.97 | 420 | 226 | 0.23 / 912.19 | 2 | 2 |
2 | 12 | 1165.88 | 5 | 15.16 | 1824 | 138 | 0.36 / 912.33 | 2 | 2 |
3 | 7 | 2004.52 | 34 | 14.77 | 2752 | 1382 | 1.75 / 913.71 | 2 | 2 |
4 | 13 | 1472.08 | 22 | 14.78 | 2157 | 701 | 2.45 / 914.41 | 2 | 3 |
5 | 13 | 922.24 | 22 | 14.82 | 1509 | 492 | 2.94 / 914.90 | 2 | 2 |
6 | 13 | 316.16 | 22 | 14.94 | 756 | 248 | 3.19 / 915.15 | 2 | 3 |
7 | 13 | 104.08 | 22 | 15.00 | 453 | 149 | 3.34 / 915.30 | 2 | 2 |
8 | 13 | 33.64 | 22 | 15.01 | 363 | 120 | 3.46 / 915.42 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.98 | 292 | 765 | 4.22 / 916.19 | 2 | 11 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 36 | 14.98 | 411 | 222 | 0.22 / 907.95 | 2 | 2 |
2 | 12 | 1167.08 | 5 | 15.16 | 1830 | 139 | 0.36 / 908.09 | 2 | 2 |
3 | 7 | 2003.92 | 34 | 14.78 | 2741 | 1377 | 1.74 / 909.46 | 2 | 2 |
4 | 13 | 1585.04 | 22 | 14.77 | 2287 | 743 | 2.48 / 910.21 | 2 | 3 |
5 | 13 | 995.04 | 22 | 14.81 | 1589 | 518 | 3.00 / 910.73 | 2 | 3 |
6 | 13 | 266.44 | 22 | 14.96 | 689 | 227 | 3.23 / 910.95 | 2 | 3 |
7 | 13 | 104.48 | 22 | 15.01 | 441 | 146 | 3.37 / 911.10 | 2 | 2 |
8 | 13 | 60.04 | 22 | 15.01 | 374 | 124 | 3.49 / 911.22 | 2 | 3 |
9 | 8 | 0.12 | 175 | 14.99 | 283 | 742 | 4.24 / 911.96 | 2 | 8 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.40 | 36 | 14.97 | 415 | 224 | 0.22 / 903.72 | 2 | 2 |
2 | 12 | 1155.00 | 5 | 15.16 | 1821 | 138 | 0.36 / 903.86 | 2 | 2 |
3 | 7 | 2006.52 | 34 | 14.78 | 2734 | 1374 | 1.74 / 905.23 | 2 | 2 |
4 | 13 | 1604.32 | 22 | 14.77 | 2297 | 746 | 2.48 / 905.98 | 2 | 3 |
5 | 13 | 997.68 | 22 | 14.81 | 1594 | 519 | 3.00 / 906.50 | 2 | 3 |
6 | 13 | 270.16 | 22 | 14.96 | 687 | 226 | 3.23 / 906.72 | 2 | 3 |
7 | 13 | 101.76 | 22 | 15.01 | 435 | 144 | 3.37 / 906.87 | 2 | 2 |
8 | 13 | 54.28 | 22 | 15.01 | 367 | 121 | 3.49 / 906.99 | 2 | 2 |
9 | 8 | 0.20 | 175 | 14.99 | 282 | 740 | 4.23 / 907.73 | 2 | 8 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 36 | 14.97 | 415 | 224 | 0.22 / 899.50 | 2 | 2 |
2 | 12 | 1186.80 | 5 | 15.16 | 1862 | 141 | 0.36 / 899.64 | 2 | 2 |
3 | 7 | 2004.48 | 34 | 14.78 | 2736 | 1375 | 1.74 / 901.02 | 2 | 3 |
4 | 13 | 1583.96 | 22 | 14.78 | 2282 | 742 | 2.48 / 901.76 | 2 | 3 |
5 | 13 | 857.36 | 22 | 14.84 | 1426 | 466 | 2.95 / 902.22 | 2 | 3 |
6 | 13 | 305.52 | 22 | 14.95 | 736 | 242 | 3.19 / 902.47 | 2 | 2 |
7 | 13 | 108.32 | 22 | 15.00 | 452 | 149 | 3.34 / 902.61 | 2 | 2 |
8 | 13 | 34.96 | 22 | 15.02 | 346 | 114 | 3.45 / 902.73 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.99 | 292 | 766 | 4.22 / 903.50 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 36 | 14.97 | 419 | 226 | 0.23 / 895.29 | 2 | 2 |
2 | 12 | 1185.40 | 5 | 15.16 | 1870 | 142 | 0.37 / 895.43 | 2 | 2 |
3 | 7 | 2005.88 | 34 | 14.78 | 2724 | 1369 | 1.74 / 896.80 | 2 | 3 |
4 | 13 | 1610.44 | 22 | 14.77 | 2308 | 750 | 2.49 / 897.55 | 2 | 3 |
5 | 13 | 883.08 | 22 | 14.83 | 1456 | 475 | 2.96 / 898.03 | 2 | 3 |
6 | 13 | 299.00 | 22 | 14.95 | 728 | 239 | 3.20 / 898.27 | 2 | 3 |
7 | 13 | 108.28 | 22 | 15.00 | 445 | 147 | 3.35 / 898.41 | 2 | 2 |
8 | 13 | 60.80 | 22 | 15.01 | 375 | 124 | 3.47 / 898.54 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.99 | 282 | 740 | 4.21 / 899.28 | 2 | 9 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.28 | 36 | 14.96 | 424 | 228 | 0.23 / 891.10 | 2 | 2 |
2 | 12 | 1177.64 | 5 | 15.15 | 1874 | 142 | 0.37 / 891.24 | 2 | 2 |
3 | 7 | 2005.52 | 34 | 14.78 | 2747 | 1380 | 1.75 / 892.62 | 2 | 2 |
4 | 13 | 1468.44 | 22 | 14.78 | 2166 | 704 | 2.46 / 893.33 | 2 | 3 |
5 | 13 | 922.96 | 22 | 14.82 | 1518 | 495 | 2.95 / 893.82 | 2 | 2 |
6 | 13 | 231.40 | 22 | 14.97 | 633 | 208 | 3.16 / 894.03 | 2 | 2 |
7 | 13 | 136.40 | 22 | 14.99 | 497 | 164 | 3.32 / 894.20 | 2 | 3 |
8 | 13 | 45.12 | 22 | 15.02 | 353 | 117 | 3.44 / 894.31 | 2 | 2 |
9 | 8 | 0.04 | 175 | 14.99 | 287 | 753 | 4.19 / 895.07 | 2 | 8 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 36 | 14.96 | 415 | 224 | 0.22 / 886.78 | 2 | 2 |
2 | 12 | 1172.24 | 5 | 15.16 | 1854 | 141 | 0.36 / 886.92 | 2 | 2 |
3 | 7 | 2004.68 | 34 | 14.78 | 2766 | 1390 | 1.75 / 888.31 | 2 | 2 |
4 | 13 | 1596.04 | 22 | 14.77 | 2308 | 750 | 2.50 / 889.06 | 2 | 3 |
5 | 13 | 1013.76 | 22 | 14.80 | 1623 | 528 | 3.03 / 889.59 | 2 | 3 |
6 | 13 | 283.16 | 22 | 14.95 | 716 | 235 | 3.27 / 889.82 | 2 | 3 |
7 | 13 | 112.92 | 22 | 15.00 | 470 | 155 | 3.42 / 889.98 | 2 | 2 |
8 | 13 | 63.36 | 22 | 15.00 | 392 | 129 | 3.55 / 890.11 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 292 | 766 | 4.32 / 890.87 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.84 | 36 | 14.95 | 430 | 231 | 0.23 / 882.44 | 2 | 2 |
2 | 12 | 1173.00 | 5 | 15.17 | 1829 | 139 | 0.37 / 882.58 | 2 | 2 |
3 | 7 | 2003.36 | 34 | 14.78 | 2745 | 1379 | 1.75 / 883.96 | 2 | 2 |
4 | 13 | 1589.04 | 22 | 14.78 | 2291 | 745 | 2.49 / 884.71 | 2 | 3 |
5 | 13 | 981.64 | 22 | 14.82 | 1588 | 518 | 3.01 / 885.22 | 2 | 3 |
6 | 13 | 386.96 | 22 | 14.92 | 851 | 279 | 3.29 / 885.50 | 2 | 3 |
7 | 13 | 115.76 | 22 | 14.99 | 473 | 156 | 3.45 / 885.66 | 2 | 3 |
8 | 13 | 31.44 | 22 | 15.01 | 349 | 115 | 3.56 / 885.77 | 2 | 2 |
9 | 8 | 0.04 | 175 | 14.98 | 298 | 781 | 4.34 / 886.55 | 2 | 10 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 36 | 14.95 | 426 | 229 | 0.23 / 878.19 | 2 | 2 |
2 | 12 | 1191.64 | 5 | 15.16 | 1879 | 142 | 0.37 / 878.33 | 2 | 2 |
3 | 7 | 2007.72 | 34 | 14.78 | 2741 | 1377 | 1.75 / 879.71 | 2 | 2 |
4 | 13 | 1471.56 | 22 | 14.79 | 2163 | 704 | 2.45 / 880.41 | 2 | 2 |
5 | 13 | 912.20 | 22 | 14.83 | 1494 | 487 | 2.94 / 880.90 | 2 | 3 |
6 | 13 | 320.48 | 22 | 14.94 | 764 | 251 | 3.19 / 881.15 | 2 | 3 |
7 | 13 | 96.32 | 22 | 15.00 | 456 | 150 | 3.34 / 881.30 | 2 | 2 |
8 | 13 | 27.88 | 22 | 15.01 | 366 | 121 | 3.46 / 881.42 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.98 | 302 | 792 | 4.25 / 882.21 | 2 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 36 | 14.95 | 432 | 233 | 0.23 / 873.78 | 2 | 2 |
2 | 12 | 1169.56 | 5 | 15.17 | 1822 | 138 | 0.37 / 873.92 | 2 | 2 |
3 | 7 | 2005.80 | 34 | 14.78 | 2752 | 1383 | 1.75 / 875.30 | 2 | 2 |
4 | 13 | 1601.56 | 22 | 14.77 | 2321 | 754 | 2.51 / 876.06 | 2 | 3 |
5 | 13 | 1000.44 | 22 | 14.81 | 1617 | 527 | 3.03 / 876.58 | 2 | 3 |
6 | 13 | 390.28 | 22 | 14.92 | 875 | 287 | 3.32 / 876.87 | 2 | 3 |
7 | 13 | 113.80 | 22 | 14.99 | 484 | 160 | 3.48 / 877.03 | 2 | 2 |
8 | 13 | 34.92 | 22 | 15.01 | 372 | 123 | 3.60 / 877.15 | 2 | 3 |
9 | 8 | 0.00 | 175 | 14.98 | 307 | 805 | 4.41 / 877.96 | 2 | 10 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 36 | 14.96 | 412 | 222 | 0.22 / 869.51 | 2 | 2 |
2 | 12 | 1193.28 | 5 | 15.17 | 1851 | 140 | 0.36 / 869.65 | 2 | 2 |
3 | 7 | 2008.08 | 35 | 14.79 | 2745 | 1421 | 1.78 / 871.07 | 2 | 2 |
4 | 13 | 1456.08 | 22 | 14.80 | 2121 | 691 | 2.47 / 871.76 | 2 | 3 |
5 | 13 | 883.64 | 22 | 14.84 | 1454 | 475 | 2.95 / 872.24 | 2 | 3 |
6 | 13 | 300.20 | 22 | 14.94 | 739 | 243 | 3.19 / 872.48 | 2 | 3 |
7 | 13 | 87.76 | 22 | 15.00 | 438 | 145 | 3.34 / 872.63 | 2 | 2 |
8 | 13 | 47.84 | 22 | 15.00 | 383 | 126 | 3.46 / 872.75 | 2 | 2 |
9 | 8 | 0.20 | 175 | 14.97 | 303 | 794 | 4.26 / 873.55 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 36 | 14.95 | 425 | 229 | 0.23 / 865.11 | 2 | 2 |
2 | 12 | 1183.68 | 5 | 15.16 | 1865 | 141 | 0.37 / 865.25 | 2 | 2 |
3 | 7 | 2002.88 | 35 | 14.78 | 2748 | 1422 | 1.79 / 866.67 | 2 | 2 |
4 | 13 | 1731.20 | 22 | 14.75 | 2473 | 802 | 2.59 / 867.48 | 2 | 3 |
5 | 13 | 984.72 | 22 | 14.81 | 1597 | 520 | 3.11 / 868.00 | 2 | 3 |
6 | 13 | 259.16 | 22 | 14.96 | 702 | 231 | 3.35 / 868.23 | 2 | 3 |
7 | 13 | 76.64 | 22 | 15.01 | 427 | 141 | 3.49 / 868.37 | 2 | 2 |
8 | 13 | 42.08 | 22 | 15.01 | 383 | 126 | 3.61 / 868.49 | 2 | 2 |
9 | 8 | 0.16 | 175 | 14.98 | 304 | 797 | 4.41 / 869.29 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 36 | 14.95 | 418 | 225 | 0.22 / 860.72 | 2 | 2 |
2 | 12 | 1164.12 | 5 | 15.18 | 1823 | 138 | 0.36 / 860.85 | 2 | 2 |
3 | 7 | 2008.12 | 34 | 14.79 | 2740 | 1378 | 1.74 / 862.23 | 2 | 3 |
4 | 13 | 1576.36 | 22 | 14.79 | 2263 | 736 | 2.48 / 862.97 | 2 | 2 |
5 | 13 | 989.92 | 22 | 14.82 | 1579 | 515 | 2.99 / 863.48 | 2 | 3 |
6 | 13 | 394.80 | 22 | 14.92 | 889 | 292 | 3.28 / 863.77 | 2 | 3 |
7 | 13 | 112.40 | 22 | 14.99 | 491 | 162 | 3.45 / 863.94 | 2 | 3 |
8 | 13 | 32.40 | 22 | 15.00 | 379 | 125 | 3.57 / 864.06 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.97 | 313 | 820 | 4.39 / 864.88 | 2 | 10 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 36 | 14.95 | 420 | 226 | 0.23 / 856.36 | 2 | 2 |
2 | 12 | 1186.16 | 5 | 15.18 | 1838 | 140 | 0.37 / 856.50 | 2 | 2 |
3 | 7 | 2003.12 | 34 | 14.80 | 2721 | 1369 | 1.73 / 857.87 | 2 | 3 |
4 | 13 | 1585.40 | 22 | 14.78 | 2279 | 741 | 2.48 / 858.61 | 2 | 3 |
5 | 13 | 1004.04 | 22 | 14.82 | 1610 | 525 | 3.00 / 859.13 | 2 | 3 |
6 | 13 | 388.44 | 22 | 14.92 | 879 | 289 | 3.29 / 859.42 | 2 | 3 |
7 | 13 | 114.00 | 22 | 14.99 | 479 | 158 | 3.45 / 859.58 | 2 | 3 |
8 | 13 | 35.60 | 22 | 15.01 | 368 | 122 | 3.57 / 859.70 | 2 | 3 |
9 | 8 | 0.16 | 175 | 14.98 | 301 | 789 | 4.36 / 860.49 | 2 | 11 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.92 | 36 | 14.96 | 425 | 229 | 0.23 / 852.07 | 2 | 2 |
2 | 12 | 1173.04 | 5 | 15.17 | 1844 | 140 | 0.37 / 852.21 | 2 | 2 |
3 | 7 | 2005.80 | 34 | 14.79 | 2745 | 1380 | 1.75 / 853.59 | 2 | 3 |
4 | 13 | 1601.24 | 22 | 14.78 | 2294 | 746 | 2.50 / 854.34 | 2 | 3 |
5 | 13 | 880.56 | 22 | 14.84 | 1466 | 479 | 2.97 / 854.81 | 2 | 3 |
6 | 13 | 299.28 | 22 | 14.95 | 738 | 243 | 3.22 / 855.06 | 2 | 3 |
7 | 13 | 96.92 | 22 | 15.00 | 453 | 149 | 3.37 / 855.21 | 2 | 3 |
8 | 13 | 52.92 | 22 | 15.00 | 390 | 129 | 3.49 / 855.34 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.98 | 304 | 797 | 4.29 / 856.13 | 2 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 36 | 14.96 | 414 | 223 | 0.22 / 847.69 | 2 | 2 |
2 | 12 | 1185.72 | 5 | 15.17 | 1860 | 141 | 0.36 / 847.83 | 2 | 2 |
3 | 7 | 2003.16 | 34 | 14.79 | 2759 | 1387 | 1.75 / 849.22 | 2 | 2 |
4 | 13 | 1572.64 | 22 | 14.79 | 2289 | 745 | 2.50 / 849.97 | 2 | 2 |
5 | 13 | 985.00 | 22 | 14.82 | 1589 | 518 | 3.01 / 850.48 | 2 | 3 |
6 | 13 | 359.52 | 22 | 14.93 | 833 | 274 | 3.29 / 850.76 | 2 | 3 |
7 | 13 | 107.84 | 22 | 15.00 | 484 | 160 | 3.45 / 850.92 | 2 | 3 |
8 | 13 | 35.40 | 22 | 15.01 | 377 | 124 | 3.57 / 851.04 | 2 | 2 |
9 | 8 | 0.16 | 175 | 14.98 | 305 | 800 | 4.37 / 851.84 | 2 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 36 | 14.96 | 422 | 227 | 0.23 / 843.40 | 2 | 2 |
2 | 12 | 1178.68 | 5 | 15.16 | 1877 | 142 | 0.37 / 843.54 | 2 | 2 |
3 | 7 | 2004.28 | 34 | 14.79 | 2751 | 1383 | 1.75 / 844.93 | 2 | 3 |
4 | 13 | 1600.60 | 22 | 14.78 | 2315 | 753 | 2.51 / 845.68 | 2 | 3 |
5 | 13 | 1010.60 | 22 | 14.81 | 1611 | 525 | 3.03 / 846.20 | 2 | 3 |
6 | 13 | 271.32 | 22 | 14.96 | 698 | 230 | 3.26 / 846.43 | 2 | 3 |
7 | 13 | 88.16 | 22 | 15.01 | 436 | 144 | 3.40 / 846.58 | 2 | 2 |
8 | 13 | 29.12 | 22 | 15.02 | 355 | 117 | 3.52 / 846.70 | 2 | 2 |
9 | 8 | 0.04 | 175 | 14.99 | 295 | 774 | 4.30 / 847.47 | 2 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 36 | 14.96 | 417 | 225 | 0.22 / 839.11 | 2 | 2 |
2 | 12 | 1178.52 | 5 | 15.17 | 1840 | 140 | 0.36 / 839.25 | 2 | 2 |
3 | 7 | 2002.08 | 34 | 14.80 | 2722 | 1370 | 1.73 / 840.62 | 2 | 3 |
4 | 13 | 1582.88 | 22 | 14.79 | 2284 | 743 | 2.48 / 841.36 | 2 | 3 |
5 | 13 | 992.48 | 22 | 14.82 | 1592 | 519 | 3.00 / 841.88 | 2 | 3 |
6 | 13 | 268.72 | 22 | 14.96 | 694 | 228 | 3.22 / 842.11 | 2 | 3 |
7 | 13 | 81.76 | 22 | 15.01 | 427 | 141 | 3.37 / 842.25 | 2 | 2 |
8 | 13 | 46.68 | 22 | 15.01 | 380 | 125 | 3.49 / 842.38 | 2 | 3 |
9 | 8 | 0.12 | 175 | 14.98 | 304 | 797 | 4.29 / 843.17 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 36 | 14.96 | 421 | 227 | 0.23 / 834.90 | 2 | 2 |
2 | 12 | 1187.64 | 5 | 15.17 | 1858 | 141 | 0.37 / 835.04 | 2 | 2 |
3 | 7 | 2004.44 | 34 | 14.80 | 2735 | 1376 | 1.74 / 836.41 | 2 | 3 |
4 | 13 | 1460.96 | 22 | 14.80 | 2135 | 695 | 2.44 / 837.11 | 2 | 3 |
5 | 13 | 891.20 | 22 | 14.84 | 1481 | 484 | 2.92 / 837.59 | 2 | 3 |
6 | 13 | 306.96 | 22 | 14.95 | 760 | 250 | 3.17 / 837.84 | 2 | 3 |
7 | 13 | 92.48 | 22 | 15.00 | 446 | 147 | 3.32 / 837.99 | 2 | 2 |
8 | 13 | 25.56 | 22 | 15.01 | 357 | 118 | 3.44 / 838.11 | 2 | 3 |
9 | 8 | 0.12 | 175 | 14.98 | 297 | 779 | 4.22 / 838.89 | 2 | 10 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 36 | 14.96 | 413 | 222 | 0.22 / 830.62 | 2 | 2 |
2 | 12 | 1157.60 | 5 | 15.17 | 1840 | 140 | 0.36 / 830.76 | 2 | 2 |
3 | 7 | 2003.44 | 35 | 14.78 | 2741 | 1418 | 1.78 / 832.17 | 2 | 2 |
4 | 13 | 1574.24 | 22 | 14.78 | 2268 | 737 | 2.52 / 832.91 | 2 | 3 |
5 | 13 | 890.60 | 22 | 14.84 | 1465 | 478 | 3.00 / 833.39 | 2 | 3 |
6 | 13 | 323.12 | 22 | 14.94 | 758 | 249 | 3.24 / 833.64 | 2 | 3 |
7 | 13 | 96.96 | 22 | 15.00 | 446 | 147 | 3.39 / 833.79 | 2 | 3 |
8 | 13 | 28.00 | 22 | 15.01 | 344 | 114 | 3.51 / 833.90 | 2 | 2 |
9 | 8 | 0.04 | 175 | 14.98 | 294 | 771 | 4.28 / 834.67 | 2 | 10 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 36 | 14.97 | 415 | 224 | 0.22 / 826.30 | 2 | 2 |
2 | 12 | 1170.96 | 5 | 15.17 | 1832 | 139 | 0.36 / 826.44 | 2 | 2 |
3 | 7 | 2002.84 | 34 | 14.79 | 2733 | 1374 | 1.74 / 827.81 | 2 | 3 |
4 | 13 | 1576.00 | 22 | 14.79 | 2273 | 740 | 2.48 / 828.55 | 2 | 2 |
5 | 13 | 987.08 | 22 | 14.83 | 1576 | 514 | 2.99 / 829.07 | 2 | 3 |
6 | 13 | 395.20 | 22 | 14.92 | 863 | 283 | 3.27 / 829.35 | 2 | 3 |
7 | 13 | 115.60 | 22 | 14.99 | 479 | 158 | 3.43 / 829.51 | 2 | 3 |
8 | 13 | 32.36 | 22 | 15.01 | 352 | 116 | 3.55 / 829.63 | 2 | 3 |
9 | 8 | 0.08 | 175 | 14.98 | 293 | 768 | 4.32 / 830.39 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 36 | 14.96 | 412 | 222 | 0.22 / 822.07 | 2 | 2 |
2 | 12 | 1160.28 | 5 | 15.18 | 1829 | 139 | 0.36 / 822.21 | 2 | 2 |
3 | 7 | 2002.08 | 34 | 14.80 | 2715 | 1366 | 1.73 / 823.58 | 2 | 3 |
4 | 13 | 1573.52 | 22 | 14.80 | 2268 | 738 | 2.47 / 824.32 | 2 | 3 |
5 | 13 | 993.12 | 22 | 14.83 | 1595 | 520 | 2.99 / 824.84 | 2 | 3 |
6 | 13 | 266.80 | 22 | 14.97 | 692 | 228 | 3.21 / 825.06 | 2 | 3 |
7 | 13 | 85.88 | 22 | 15.01 | 430 | 142 | 3.36 / 825.21 | 2 | 2 |
8 | 13 | 26.12 | 22 | 15.02 | 340 | 112 | 3.47 / 825.32 | 2 | 3 |
9 | 8 | 0.04 | 175 | 14.99 | 289 | 758 | 4.23 / 826.08 | 2 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 36 | 14.96 | 417 | 225 | 0.22 / 817.71 | 2 | 2 |
2 | 12 | 1182.40 | 5 | 15.18 | 1845 | 140 | 0.36 / 817.85 | 2 | 2 |
3 | 7 | 2004.60 | 34 | 14.80 | 2720 | 1369 | 1.73 / 819.22 | 2 | 2 |
4 | 13 | 1726.56 | 22 | 14.77 | 2442 | 794 | 2.53 / 820.01 | 2 | 3 |
5 | 13 | 970.20 | 22 | 14.83 | 1574 | 514 | 3.04 / 820.53 | 2 | 3 |
6 | 13 | 373.60 | 22 | 14.93 | 839 | 276 | 3.32 / 820.80 | 2 | 3 |
7 | 13 | 113.84 | 22 | 15.00 | 479 | 158 | 3.47 / 820.96 | 2 | 3 |
8 | 13 | 31.12 | 22 | 15.01 | 361 | 119 | 3.59 / 821.08 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.98 | 294 | 771 | 4.36 / 821.85 | 2 | 11 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 36 | 14.96 | 404 | 218 | 0.22 / 813.35 | 2 | 2 |
2 | 12 | 1171.56 | 5 | 15.17 | 1836 | 139 | 0.36 / 813.48 | 2 | 2 |
3 | 7 | 2005.68 | 34 | 14.79 | 2764 | 1390 | 1.75 / 814.87 | 2 | 3 |
4 | 13 | 1589.60 | 22 | 14.78 | 2305 | 749 | 2.50 / 815.62 | 2 | 2 |
5 | 13 | 986.64 | 22 | 14.82 | 1600 | 522 | 3.02 / 816.15 | 2 | 3 |
6 | 13 | 389.36 | 22 | 14.92 | 875 | 287 | 3.31 / 816.43 | 2 | 3 |
7 | 13 | 121.96 | 22 | 14.99 | 501 | 165 | 3.47 / 816.60 | 2 | 2 |
8 | 13 | 32.92 | 22 | 15.01 | 349 | 115 | 3.59 / 816.71 | 2 | 3 |
9 | 8 | 0.04 | 175 | 14.98 | 295 | 773 | 4.36 / 817.49 | 2 | 10 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 36 | 14.96 | 420 | 226 | 0.23 / 809.17 | 2 | 2 |
2 | 12 | 1164.24 | 5 | 15.18 | 1838 | 140 | 0.37 / 809.31 | 2 | 2 |
3 | 7 | 2005.08 | 34 | 14.80 | 2750 | 1384 | 1.75 / 810.69 | 2 | 2 |
4 | 13 | 1452.04 | 22 | 14.81 | 2134 | 695 | 2.44 / 811.39 | 2 | 3 |
5 | 13 | 859.84 | 22 | 14.85 | 1452 | 474 | 2.92 / 811.86 | 2 | 3 |
6 | 13 | 308.12 | 22 | 14.95 | 757 | 249 | 3.17 / 812.11 | 2 | 3 |
7 | 13 | 102.00 | 22 | 15.00 | 446 | 147 | 3.32 / 812.26 | 2 | 2 |
8 | 13 | 29.40 | 22 | 15.01 | 345 | 114 | 3.43 / 812.37 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 289 | 758 | 4.19 / 813.13 | 2 | 10 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 36 | 14.98 | 412 | 222 | 0.22 / 804.92 | 2 | 2 |
2 | 12 | 1177.80 | 5 | 15.17 | 1851 | 140 | 0.36 / 805.06 | 2 | 2 |
3 | 7 | 2001.68 | 34 | 14.80 | 2755 | 1386 | 1.75 / 806.44 | 2 | 2 |
4 | 13 | 1579.76 | 22 | 14.79 | 2282 | 743 | 2.49 / 807.19 | 2 | 3 |
5 | 13 | 868.28 | 22 | 14.84 | 1463 | 478 | 2.97 / 807.66 | 2 | 3 |
6 | 13 | 295.60 | 22 | 14.95 | 734 | 241 | 3.21 / 807.90 | 2 | 3 |
7 | 13 | 100.44 | 22 | 15.00 | 454 | 150 | 3.36 / 808.05 | 2 | 3 |
8 | 13 | 25.84 | 22 | 15.02 | 342 | 113 | 3.47 / 808.17 | 2 | 2 |
9 | 8 | 0.04 | 175 | 14.98 | 295 | 773 | 4.25 / 808.94 | 2 | 7 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 36 | 14.97 | 418 | 225 | 0.23 / 800.78 | 2 | 2 |
2 | 12 | 1190.04 | 5 | 15.18 | 1873 | 142 | 0.37 / 800.92 | 2 | 2 |
3 | 7 | 2003.44 | 34 | 14.80 | 2726 | 1372 | 1.74 / 802.30 | 2 | 3 |
4 | 13 | 1587.44 | 22 | 14.79 | 2286 | 744 | 2.48 / 803.04 | 2 | 3 |
5 | 13 | 1003.44 | 22 | 14.82 | 1604 | 523 | 3.01 / 803.56 | 2 | 3 |
6 | 13 | 262.28 | 22 | 14.96 | 687 | 226 | 3.23 / 803.79 | 2 | 3 |
7 | 13 | 105.20 | 22 | 15.00 | 451 | 149 | 3.38 / 803.94 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.00 | 288 | 756 | 4.14 / 804.69 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 36 | 14.97 | 428 | 231 | 0.23 / 796.44 | 2 | 2 |
2 | 12 | 1155.80 | 5 | 15.19 | 1819 | 138 | 0.37 / 796.58 | 2 | 2 |
3 | 7 | 2007.36 | 34 | 14.79 | 2761 | 1388 | 1.76 / 797.97 | 2 | 2 |
4 | 13 | 1592.04 | 22 | 14.79 | 2318 | 754 | 2.51 / 798.72 | 2 | 3 |
5 | 13 | 1008.24 | 22 | 14.82 | 1641 | 535 | 3.05 / 799.26 | 2 | 3 |
6 | 13 | 274.84 | 22 | 14.96 | 717 | 236 | 3.28 / 799.49 | 2 | 3 |
7 | 13 | 98.48 | 22 | 15.01 | 457 | 151 | 3.43 / 799.64 | 2 | 2 |
8 | 13 | 26.84 | 22 | 15.01 | 358 | 118 | 3.55 / 799.76 | 2 | 2 |
9 | 8 | 0.20 | 175 | 14.99 | 303 | 795 | 4.35 / 800.56 | 2 | 10 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 36 | 14.96 | 422 | 227 | 0.23 / 792.31 | 2 | 2 |
2 | 12 | 1167.56 | 5 | 15.18 | 1833 | 139 | 0.37 / 792.45 | 2 | 2 |
3 | 7 | 2003.08 | 34 | 14.80 | 2754 | 1386 | 1.75 / 793.84 | 2 | 3 |
4 | 13 | 1443.76 | 22 | 14.82 | 2119 | 691 | 2.44 / 794.53 | 2 | 3 |
5 | 13 | 893.56 | 22 | 14.85 | 1478 | 483 | 2.93 / 795.01 | 2 | 3 |
6 | 13 | 317.40 | 22 | 14.95 | 773 | 254 | 3.18 / 795.27 | 2 | 3 |
7 | 13 | 102.32 | 22 | 15.01 | 460 | 152 | 3.33 / 795.42 | 2 | 2 |
8 | 8 | 0.20 | 175 | 15.00 | 302 | 793 | 4.12 / 796.21 | 2 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 36 | 14.97 | 422 | 227 | 0.23 / 787.95 | 2 | 2 |
2 | 12 | 1177.16 | 5 | 15.18 | 1866 | 142 | 0.37 / 788.09 | 2 | 2 |
3 | 7 | 2003.88 | 34 | 14.79 | 2746 | 1381 | 1.75 / 789.47 | 2 | 2 |
4 | 13 | 1593.44 | 22 | 14.79 | 2298 | 748 | 2.50 / 790.22 | 2 | 3 |
5 | 13 | 999.96 | 22 | 14.83 | 1603 | 523 | 3.02 / 790.75 | 2 | 3 |
6 | 13 | 390.32 | 22 | 14.92 | 865 | 284 | 3.30 / 791.03 | 2 | 3 |
7 | 13 | 119.84 | 22 | 14.99 | 489 | 161 | 3.47 / 791.19 | 2 | 3 |
8 | 13 | 29.00 | 22 | 15.01 | 353 | 117 | 3.58 / 791.31 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.98 | 297 | 779 | 4.36 / 792.09 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 36 | 14.96 | 421 | 227 | 0.23 / 783.79 | 2 | 2 |
2 | 12 | 1177.60 | 5 | 15.18 | 1852 | 141 | 0.37 / 783.93 | 2 | 2 |
3 | 7 | 2005.44 | 34 | 14.79 | 2758 | 1387 | 1.75 / 785.31 | 2 | 3 |
4 | 13 | 1577.44 | 22 | 14.80 | 2288 | 745 | 2.50 / 786.06 | 2 | 3 |
5 | 13 | 871.00 | 22 | 14.84 | 1471 | 480 | 2.98 / 786.54 | 2 | 3 |
6 | 13 | 297.00 | 22 | 14.95 | 740 | 243 | 3.22 / 786.78 | 2 | 3 |
7 | 13 | 97.16 | 22 | 15.00 | 454 | 150 | 3.37 / 786.93 | 2 | 2 |
8 | 8 | -0.04 | 175 | 14.99 | 302 | 792 | 4.16 / 787.72 | 2 | 11 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 36 | 14.96 | 424 | 228 | 0.23 / 779.47 | 2 | 2 |
2 | 12 | 1174.72 | 5 | 15.18 | 1864 | 141 | 0.37 / 779.61 | 2 | 2 |
3 | 7 | 2004.68 | 34 | 14.79 | 2761 | 1388 | 1.76 / 781.00 | 2 | 3 |
4 | 13 | 1593.32 | 22 | 14.80 | 2297 | 748 | 2.51 / 781.74 | 2 | 3 |
5 | 13 | 1014.20 | 22 | 14.82 | 1641 | 535 | 3.04 / 782.28 | 2 | 3 |
6 | 13 | 289.04 | 22 | 14.96 | 720 | 237 | 3.28 / 782.52 | 2 | 3 |
7 | 13 | 108.16 | 22 | 15.01 | 458 | 151 | 3.43 / 782.67 | 2 | 2 |
8 | 13 | 58.28 | 22 | 15.01 | 392 | 129 | 3.56 / 782.80 | 2 | 2 |
9 | 8 | 0.16 | 175 | 14.99 | 291 | 763 | 4.32 / 783.56 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 36 | 14.96 | 426 | 229 | 0.23 / 775.26 | 2 | 2 |
2 | 12 | 1175.08 | 5 | 15.18 | 1853 | 141 | 0.37 / 775.40 | 2 | 2 |
3 | 7 | 2002.36 | 34 | 14.80 | 2727 | 1372 | 1.74 / 776.77 | 2 | 2 |
4 | 13 | 1463.80 | 22 | 14.81 | 2157 | 703 | 2.45 / 777.47 | 2 | 3 |
5 | 13 | 910.20 | 22 | 14.84 | 1492 | 487 | 2.93 / 777.96 | 2 | 3 |
6 | 13 | 219.96 | 22 | 14.98 | 633 | 209 | 3.14 / 778.17 | 2 | 2 |
7 | 13 | 118.16 | 22 | 15.00 | 485 | 160 | 3.30 / 778.33 | 2 | 3 |
8 | 13 | 29.16 | 22 | 15.02 | 358 | 118 | 3.42 / 778.45 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 301 | 790 | 4.21 / 779.24 | 2 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.76 | 36 | 14.97 | 417 | 225 | 0.22 / 770.93 | 2 | 2 |
2 | 12 | 1163.56 | 5 | 15.18 | 1815 | 138 | 0.36 / 771.07 | 2 | 2 |
3 | 7 | 2003.12 | 34 | 14.80 | 2743 | 1380 | 1.74 / 772.45 | 2 | 3 |
4 | 13 | 1587.16 | 22 | 14.79 | 2305 | 750 | 2.49 / 773.20 | 2 | 3 |
5 | 13 | 989.44 | 22 | 14.83 | 1595 | 520 | 3.01 / 773.72 | 2 | 3 |
6 | 13 | 261.20 | 22 | 14.96 | 693 | 228 | 3.24 / 773.95 | 2 | 3 |
7 | 13 | 137.76 | 22 | 14.99 | 516 | 170 | 3.41 / 774.12 | 2 | 3 |
8 | 13 | 41.28 | 22 | 15.01 | 375 | 124 | 3.54 / 774.25 | 2 | 2 |
9 | 8 | 0.16 | 175 | 14.98 | 299 | 784 | 4.32 / 775.03 | 2 | 7 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 36 | 14.96 | 428 | 231 | 0.23 / 766.64 | 2 | 2 |
2 | 12 | 1166.64 | 5 | 15.18 | 1818 | 138 | 0.37 / 766.78 | 2 | 2 |
3 | 7 | 2006.80 | 34 | 14.81 | 2736 | 1378 | 1.75 / 768.16 | 2 | 2 |
4 | 13 | 1598.92 | 22 | 14.79 | 2315 | 753 | 2.50 / 768.91 | 2 | 3 |
5 | 13 | 1023.68 | 22 | 14.83 | 1631 | 532 | 3.03 / 769.44 | 2 | 3 |
6 | 13 | 280.56 | 22 | 14.96 | 726 | 239 | 3.27 / 769.68 | 2 | 3 |
7 | 13 | 108.76 | 22 | 15.01 | 451 | 149 | 3.42 / 769.83 | 2 | 2 |
8 | 13 | 26.84 | 22 | 15.02 | 337 | 111 | 3.53 / 769.94 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 293 | 769 | 4.30 / 770.71 | 2 | 9 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 36 | 14.97 | 422 | 227 | 0.23 / 762.36 | 2 | 2 |
2 | 12 | 1168.00 | 5 | 15.18 | 1858 | 141 | 0.37 / 762.51 | 2 | 2 |
3 | 7 | 2006.24 | 35 | 14.80 | 2755 | 1427 | 1.80 / 763.93 | 2 | 2 |
4 | 13 | 1588.92 | 22 | 14.79 | 2297 | 747 | 2.54 / 764.68 | 2 | 3 |
5 | 13 | 860.80 | 22 | 14.85 | 1432 | 468 | 3.01 / 765.15 | 2 | 3 |
6 | 13 | 290.72 | 22 | 14.96 | 729 | 240 | 3.25 / 765.39 | 2 | 3 |
7 | 13 | 98.92 | 22 | 15.01 | 443 | 146 | 3.40 / 765.53 | 2 | 2 |
8 | 13 | 31.16 | 22 | 15.02 | 343 | 113 | 3.51 / 765.65 | 2 | 2 |
9 | 8 | 0.08 | 175 | 14.99 | 291 | 763 | 4.27 / 766.41 | 2 | 11 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 36 | 14.97 | 427 | 230 | 0.23 / 758.06 | 2 | 2 |
2 | 12 | 1186.72 | 5 | 15.18 | 1862 | 141 | 0.37 / 758.20 | 2 | 2 |
3 | 7 | 2006.28 | 34 | 14.81 | 2748 | 1384 | 1.76 / 759.58 | 2 | 2 |
4 | 13 | 1592.56 | 22 | 14.79 | 2311 | 752 | 2.51 / 760.33 | 2 | 3 |
5 | 13 | 879.76 | 22 | 14.85 | 1460 | 477 | 2.98 / 760.81 | 2 | 3 |
6 | 13 | 308.96 | 22 | 14.95 | 766 | 252 | 3.24 / 761.06 | 2 | 3 |
7 | 13 | 115.80 | 22 | 15.01 | 466 | 154 | 3.39 / 761.22 | 2 | 2 |
8 | 13 | 61.40 | 22 | 15.01 | 394 | 130 | 3.52 / 761.35 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 301 | 790 | 4.31 / 762.14 | 2 | 8 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 36 | 14.96 | 425 | 229 | 0.23 / 753.79 | 2 | 2 |
2 | 12 | 1160.88 | 5 | 15.19 | 1817 | 138 | 0.37 / 753.93 | 2 | 2 |
3 | 7 | 2005.32 | 34 | 14.81 | 2750 | 1385 | 1.75 / 755.31 | 2 | 2 |
4 | 13 | 1608.92 | 22 | 14.79 | 2331 | 758 | 2.51 / 756.07 | 2 | 3 |
5 | 13 | 1004.32 | 22 | 14.83 | 1613 | 526 | 3.04 / 756.60 | 2 | 3 |
6 | 13 | 382.48 | 22 | 14.93 | 866 | 284 | 3.32 / 756.88 | 2 | 3 |
7 | 13 | 124.36 | 22 | 15.00 | 484 | 160 | 3.48 / 757.04 | 2 | 2 |
8 | 8 | 0.08 | 175 | 14.99 | 300 | 787 | 4.27 / 757.83 | 2 | 7 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 36 | 14.97 | 428 | 231 | 0.23 / 749.54 | 2 | 2 |
2 | 12 | 1155.84 | 5 | 15.18 | 1832 | 139 | 0.37 / 749.68 | 2 | 2 |
3 | 7 | 2004.00 | 34 | 14.80 | 2744 | 1381 | 1.75 / 751.06 | 2 | 3 |
4 | 13 | 1466.28 | 22 | 14.81 | 2164 | 705 | 2.46 / 751.77 | 2 | 3 |
5 | 13 | 912.60 | 22 | 14.84 | 1523 | 497 | 2.95 / 752.27 | 2 | 3 |
6 | 13 | 315.12 | 22 | 14.95 | 771 | 254 | 3.21 / 752.52 | 2 | 3 |
7 | 13 | 113.16 | 22 | 15.00 | 466 | 154 | 3.36 / 752.67 | 2 | 2 |
8 | 13 | 28.52 | 22 | 15.02 | 343 | 113 | 3.47 / 752.79 | 2 | 2 |
9 | 8 | 0.12 | 175 | 14.99 | 295 | 774 | 4.25 / 753.56 | 2 | 10 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 36 | 14.97 | 422 | 227 | 0.23 / 745.40 | 2 | 2 |
2 | 12 | 1178.76 | 5 | 15.19 | 1851 | 141 | 0.37 / 745.54 | 2 | 2 |
3 | 7 | 2004.84 | 34 | 14.81 | 2730 | 1375 | 1.74 / 746.92 | 2 | 2 |
4 | 13 | 1591.84 | 22 | 14.80 | 2291 | 746 | 2.49 / 747.66 | 2 | 3 |
5 | 13 | 873.88 | 22 | 14.86 | 1446 | 473 | 2.96 / 748.14 | 2 | 3 |
6 | 13 | 306.28 | 22 | 14.96 | 751 | 247 | 3.21 / 748.38 | 2 | 3 |
7 | 13 | 121.56 | 22 | 15.01 | 470 | 155 | 3.36 / 748.54 | 2 | 2 |
8 | 8 | 0.24 | 175 | 15.00 | 295 | 774 | 4.14 / 749.31 | 2 | 10 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 36 | 14.98 | 425 | 229 | 0.23 / 741.26 | 2 | 2 |
2 | 12 | 1160.20 | 5 | 15.19 | 1825 | 139 | 0.37 / 741.40 | 2 | 2 |
3 | 7 | 2002.48 | 34 | 14.81 | 2736 | 1378 | 1.75 / 742.78 | 2 | 3 |
4 | 13 | 1580.92 | 22 | 14.81 | 2282 | 744 | 2.49 / 743.52 | 2 | 3 |
5 | 13 | 886.56 | 22 | 14.85 | 1465 | 479 | 2.97 / 744.00 | 2 | 3 |
6 | 13 | 309.04 | 22 | 14.95 | 763 | 251 | 3.22 / 744.25 | 2 | 3 |
7 | 13 | 121.08 | 22 | 15.00 | 476 | 157 | 3.38 / 744.41 | 2 | 3 |
8 | 8 | 0.24 | 175 | 15.00 | 292 | 766 | 4.14 / 745.17 | 2 | 7 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 36 | 14.96 | 421 | 227 | 0.23 / 737.12 | 2 | 2 |
2 | 12 | 1164.80 | 5 | 15.19 | 1824 | 139 | 0.37 / 737.26 | 2 | 2 |
3 | 7 | 2005.60 | 35 | 14.80 | 2729 | 1414 | 1.78 / 738.67 | 2 | 3 |
4 | 13 | 1568.44 | 22 | 14.81 | 2252 | 734 | 2.51 / 739.41 | 2 | 3 |
5 | 13 | 872.24 | 22 | 14.86 | 1448 | 473 | 2.99 / 739.88 | 2 | 3 |
6 | 13 | 308.80 | 22 | 14.96 | 750 | 247 | 3.23 / 740.13 | 2 | 3 |
7 | 13 | 115.52 | 22 | 15.01 | 469 | 155 | 3.39 / 740.28 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.01 | 286 | 751 | 4.14 / 741.03 | 2 | 8 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 36 | 14.99 | 413 | 223 | 0.22 / 732.90 | 2 | 2 |
2 | 12 | 1178.84 | 5 | 15.19 | 1862 | 141 | 0.36 / 733.04 | 2 | 2 |
3 | 7 | 2002.80 | 34 | 14.81 | 2739 | 1379 | 1.74 / 734.42 | 2 | 3 |
4 | 13 | 1579.96 | 22 | 14.81 | 2288 | 745 | 2.49 / 735.17 | 2 | 3 |
5 | 13 | 982.92 | 22 | 14.84 | 1580 | 516 | 3.00 / 735.68 | 2 | 3 |
6 | 13 | 381.56 | 22 | 14.94 | 840 | 276 | 3.28 / 735.96 | 2 | 3 |
7 | 13 | 141.88 | 22 | 14.99 | 516 | 170 | 3.45 / 736.13 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.00 | 291 | 764 | 4.21 / 736.89 | 2 | 8 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 36 | 14.97 | 445 | 240 | 0.24 / 728.76 | 2 | 2 |
2 | 12 | 1175.08 | 5 | 15.19 | 1854 | 141 | 0.38 / 728.90 | 2 | 2 |
3 | 7 | 2001.92 | 34 | 14.82 | 2722 | 1372 | 1.75 / 730.27 | 2 | 3 |
4 | 13 | 1598.76 | 22 | 14.81 | 2286 | 745 | 2.50 / 731.01 | 2 | 3 |
5 | 13 | 1006.20 | 22 | 14.84 | 1605 | 524 | 3.02 / 731.54 | 2 | 3 |
6 | 13 | 282.28 | 22 | 14.97 | 702 | 231 | 3.25 / 731.77 | 2 | 3 |
7 | 13 | 123.64 | 22 | 15.01 | 459 | 152 | 3.40 / 731.92 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.01 | 289 | 759 | 4.16 / 732.68 | 2 | 8 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 36 | 14.97 | 435 | 234 | 0.23 / 724.49 | 2 | 2 |
2 | 12 | 1173.04 | 5 | 15.19 | 1856 | 141 | 0.38 / 724.64 | 2 | 2 |
3 | 7 | 2001.72 | 34 | 14.81 | 2762 | 1391 | 1.77 / 726.03 | 2 | 2 |
4 | 13 | 1582.76 | 22 | 14.80 | 2293 | 747 | 2.51 / 726.77 | 2 | 3 |
5 | 13 | 869.04 | 22 | 14.86 | 1448 | 473 | 2.99 / 727.25 | 2 | 3 |
6 | 13 | 295.12 | 22 | 14.97 | 730 | 240 | 3.23 / 727.49 | 2 | 3 |
7 | 13 | 118.56 | 22 | 15.01 | 474 | 157 | 3.38 / 727.64 | 2 | 2 |
8 | 13 | 28.12 | 22 | 15.03 | 351 | 116 | 3.50 / 727.76 | 2 | 2 |
9 | 8 | 0.08 | 175 | 15.00 | 288 | 756 | 4.26 / 728.52 | 2 | 8 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 36 | 14.98 | 415 | 224 | 0.22 / 720.26 | 2 | 2 |
2 | 12 | 1195.08 | 5 | 15.19 | 1856 | 141 | 0.36 / 720.40 | 2 | 2 |
3 | 7 | 2002.68 | 34 | 14.81 | 2746 | 1383 | 1.75 / 721.78 | 2 | 3 |
4 | 13 | 1592.72 | 22 | 14.80 | 2309 | 752 | 2.50 / 722.54 | 2 | 3 |
5 | 13 | 1003.44 | 22 | 14.84 | 1608 | 525 | 3.02 / 723.06 | 2 | 3 |
6 | 13 | 282.92 | 22 | 14.97 | 722 | 238 | 3.26 / 723.30 | 2 | 3 |
7 | 13 | 156.64 | 22 | 14.99 | 544 | 179 | 3.44 / 723.48 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.00 | 298 | 782 | 4.22 / 724.26 | 2 | 7 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 36 | 14.97 | 426 | 230 | 0.23 / 716.11 | 2 | 2 |
2 | 12 | 1187.76 | 5 | 15.18 | 1870 | 142 | 0.37 / 716.25 | 2 | 2 |
3 | 7 | 2003.28 | 35 | 14.80 | 2760 | 1430 | 1.80 / 717.68 | 2 | 2 |
4 | 13 | 1456.40 | 22 | 14.82 | 2150 | 701 | 2.50 / 718.38 | 2 | 3 |
5 | 13 | 899.76 | 22 | 14.85 | 1501 | 490 | 2.99 / 718.87 | 2 | 3 |
6 | 13 | 300.00 | 22 | 14.96 | 753 | 248 | 3.24 / 719.12 | 2 | 3 |
7 | 13 | 118.80 | 22 | 15.01 | 470 | 155 | 3.40 / 719.27 | 2 | 2 |
8 | 8 | 0.20 | 175 | 15.01 | 291 | 764 | 4.16 / 720.04 | 2 | 9 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 36 | 14.98 | 414 | 223 | 0.22 / 711.84 | 2 | 2 |
2 | 12 | 1168.56 | 5 | 15.19 | 1844 | 140 | 0.36 / 711.98 | 2 | 2 |
3 | 7 | 2008.80 | 34 | 14.81 | 2763 | 1391 | 1.75 / 713.37 | 2 | 2 |
4 | 13 | 1738.84 | 22 | 14.78 | 2465 | 802 | 2.56 / 714.17 | 2 | 2 |
5 | 13 | 974.64 | 22 | 14.85 | 1570 | 513 | 3.07 / 714.69 | 2 | 3 |
6 | 13 | 268.08 | 22 | 14.98 | 695 | 229 | 3.30 / 714.92 | 2 | 3 |
7 | 13 | 145.92 | 22 | 15.00 | 510 | 168 | 3.47 / 715.08 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.00 | 302 | 793 | 4.26 / 715.88 | 2 | 8 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 36 | 14.98 | 422 | 228 | 0.23 / 707.73 | 2 | 2 |
2 | 12 | 1184.32 | 5 | 15.19 | 1846 | 140 | 0.37 / 707.87 | 2 | 2 |
3 | 7 | 2002.28 | 34 | 14.82 | 2747 | 1384 | 1.75 / 709.25 | 2 | 2 |
4 | 13 | 1460.00 | 22 | 14.82 | 2143 | 699 | 2.45 / 709.95 | 2 | 3 |
5 | 13 | 891.28 | 22 | 14.86 | 1482 | 484 | 2.94 / 710.44 | 2 | 3 |
6 | 13 | 303.20 | 22 | 14.96 | 747 | 246 | 3.18 / 710.68 | 2 | 3 |
7 | 13 | 115.96 | 22 | 15.01 | 472 | 156 | 3.34 / 710.84 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.01 | 297 | 780 | 4.12 / 711.62 | 2 | 8 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 36 | 14.99 | 414 | 223 | 0.22 / 703.55 | 2 | 2 |
2 | 12 | 1175.84 | 5 | 15.19 | 1827 | 139 | 0.36 / 703.69 | 2 | 2 |
3 | 7 | 2002.48 | 34 | 14.82 | 2738 | 1380 | 1.74 / 705.07 | 2 | 3 |
4 | 13 | 1591.80 | 22 | 14.81 | 2284 | 744 | 2.49 / 705.81 | 2 | 2 |
5 | 13 | 998.00 | 22 | 14.85 | 1597 | 522 | 3.01 / 706.33 | 2 | 3 |
6 | 13 | 280.96 | 22 | 14.97 | 731 | 241 | 3.25 / 706.58 | 2 | 3 |
7 | 13 | 113.32 | 22 | 15.02 | 462 | 153 | 3.40 / 706.73 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.01 | 294 | 772 | 4.17 / 707.50 | 2 | 9 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 36 | 14.99 | 405 | 219 | 0.22 / 699.45 | 2 | 2 |
2 | 12 | 1167.40 | 5 | 15.20 | 1830 | 139 | 0.36 / 699.59 | 2 | 2 |
3 | 7 | 2003.00 | 34 | 14.82 | 2746 | 1384 | 1.74 / 700.97 | 2 | 2 |
4 | 13 | 1573.96 | 22 | 14.82 | 2271 | 740 | 2.48 / 701.71 | 2 | 3 |
5 | 13 | 847.08 | 22 | 14.88 | 1417 | 464 | 2.95 / 702.18 | 2 | 3 |
6 | 13 | 285.12 | 22 | 14.98 | 714 | 235 | 3.18 / 702.41 | 2 | 3 |
7 | 13 | 115.12 | 22 | 15.02 | 463 | 153 | 3.33 / 702.56 | 2 | 2 |
8 | 8 | 0.20 | 175 | 15.02 | 290 | 762 | 4.10 / 703.33 | 2 | 10 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 36 | 14.98 | 425 | 229 | 0.23 / 695.31 | 2 | 2 |
2 | 12 | 1174.08 | 5 | 15.20 | 1822 | 138 | 0.37 / 695.44 | 2 | 2 |
3 | 7 | 2005.00 | 34 | 14.82 | 2729 | 1375 | 1.74 / 696.82 | 2 | 3 |
4 | 13 | 1549.96 | 22 | 14.82 | 2244 | 732 | 2.47 / 697.55 | 2 | 3 |
5 | 13 | 969.68 | 22 | 14.86 | 1559 | 510 | 2.98 / 698.06 | 2 | 3 |
6 | 13 | 356.72 | 22 | 14.96 | 811 | 267 | 3.25 / 698.33 | 2 | 3 |
7 | 13 | 125.60 | 22 | 15.02 | 475 | 157 | 3.41 / 698.48 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.02 | 284 | 746 | 4.15 / 699.23 | 2 | 6 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 36 | 14.99 | 416 | 224 | 0.22 / 691.20 | 2 | 2 |
2 | 12 | 1176.56 | 5 | 15.19 | 1829 | 139 | 0.36 / 691.34 | 2 | 2 |
3 | 7 | 2003.52 | 34 | 14.82 | 2740 | 1381 | 1.74 / 692.72 | 2 | 2 |
4 | 13 | 1463.52 | 22 | 14.83 | 2148 | 701 | 2.44 / 693.42 | 2 | 3 |
5 | 13 | 884.60 | 22 | 14.86 | 1471 | 481 | 2.93 / 693.90 | 2 | 3 |
6 | 13 | 296.04 | 22 | 14.97 | 737 | 243 | 3.17 / 694.14 | 2 | 3 |
7 | 13 | 106.52 | 22 | 15.01 | 466 | 154 | 3.32 / 694.30 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.01 | 297 | 780 | 4.10 / 695.08 | 2 | 8 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 36 | 14.98 | 425 | 229 | 0.23 / 687.07 | 2 | 2 |
2 | 12 | 1163.84 | 5 | 15.20 | 1825 | 139 | 0.37 / 687.21 | 2 | 2 |
3 | 7 | 2006.20 | 34 | 14.82 | 2753 | 1387 | 1.76 / 688.59 | 2 | 3 |
4 | 13 | 1592.92 | 22 | 14.81 | 2296 | 748 | 2.50 / 689.34 | 2 | 3 |
5 | 13 | 868.72 | 22 | 14.87 | 1451 | 475 | 2.98 / 689.82 | 2 | 3 |
6 | 13 | 304.00 | 22 | 14.97 | 755 | 249 | 3.23 / 690.06 | 2 | 3 |
7 | 13 | 125.60 | 22 | 15.02 | 480 | 159 | 3.39 / 690.22 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.02 | 286 | 752 | 4.14 / 690.97 | 2 | 6 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 36 | 14.99 | 419 | 226 | 0.23 / 682.82 | 2 | 2 |
2 | 12 | 1168.40 | 5 | 15.20 | 1823 | 139 | 0.36 / 682.96 | 2 | 2 |
3 | 7 | 2003.04 | 34 | 14.83 | 2735 | 1379 | 1.74 / 684.34 | 2 | 3 |
4 | 13 | 1585.72 | 22 | 14.82 | 2287 | 746 | 2.49 / 685.08 | 2 | 2 |
5 | 13 | 993.12 | 22 | 14.85 | 1589 | 519 | 3.01 / 685.60 | 2 | 3 |
6 | 13 | 385.00 | 22 | 14.95 | 860 | 283 | 3.29 / 685.88 | 2 | 3 |
7 | 13 | 137.08 | 22 | 15.01 | 508 | 168 | 3.46 / 686.05 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.01 | 299 | 785 | 4.24 / 686.84 | 2 | 10 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 36 | 14.98 | 438 | 236 | 0.24 / 678.64 | 2 | 2 |
2 | 12 | 1167.12 | 5 | 15.20 | 1865 | 142 | 0.38 / 678.78 | 2 | 2 |
3 | 7 | 2003.60 | 34 | 14.82 | 2761 | 1391 | 1.77 / 680.17 | 2 | 3 |
4 | 13 | 1588.60 | 22 | 14.81 | 2299 | 749 | 2.52 / 680.92 | 2 | 3 |
5 | 13 | 869.00 | 22 | 14.88 | 1450 | 475 | 2.99 / 681.39 | 2 | 3 |
6 | 13 | 308.20 | 22 | 14.97 | 764 | 252 | 3.24 / 681.64 | 2 | 3 |
7 | 13 | 121.20 | 22 | 15.02 | 486 | 161 | 3.41 / 681.80 | 2 | 2 |
8 | 8 | 0.04 | 175 | 15.02 | 300 | 789 | 4.19 / 682.59 | 2 | 7 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 36 | 14.99 | 411 | 222 | 0.22 / 674.42 | 2 | 2 |
2 | 12 | 1167.04 | 5 | 15.20 | 1835 | 139 | 0.36 / 674.56 | 2 | 2 |
3 | 7 | 2006.32 | 34 | 14.83 | 2734 | 1379 | 1.74 / 675.93 | 2 | 3 |
4 | 13 | 1595.32 | 22 | 14.82 | 2296 | 749 | 2.49 / 676.68 | 2 | 3 |
5 | 13 | 980.80 | 22 | 14.86 | 1586 | 518 | 3.01 / 677.20 | 2 | 3 |
6 | 13 | 252.92 | 22 | 14.99 | 686 | 226 | 3.23 / 677.43 | 2 | 2 |
7 | 13 | 130.12 | 22 | 15.01 | 507 | 167 | 3.40 / 677.60 | 2 | 2 |
8 | 8 | 0.00 | 175 | 15.01 | 306 | 804 | 4.20 / 678.40 | 2 | 7 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 35 | 14.99 | 420 | 220 | 0.22 / 670.12 | 2 | 2 |
2 | 3 | 1015.84 | 1 | 15.18 | 1692 | 26 | 0.25 / 670.15 | 2 | 2 |
3 | 12 | 1177.56 | 5 | 15.19 | 1876 | 142 | 0.39 / 670.29 | 2 | 2 |
4 | 7 | 2004.68 | 34 | 14.82 | 2770 | 1396 | 1.78 / 671.69 | 2 | 2 |
5 | 13 | 1591.16 | 22 | 14.82 | 2303 | 751 | 2.54 / 672.44 | 2 | 3 |
6 | 13 | 880.40 | 22 | 14.87 | 1470 | 481 | 3.02 / 672.92 | 2 | 3 |
7 | 13 | 430.88 | 22 | 14.93 | 928 | 305 | 3.32 / 673.23 | 2 | 3 |
8 | 13 | 141.76 | 22 | 15.00 | 526 | 174 | 3.49 / 673.40 | 2 | 3 |
9 | 8 | 0.08 | 175 | 15.01 | 303 | 796 | 4.29 / 674.19 | 2 | 8 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 36 | 14.99 | 433 | 234 | 0.23 / 665.89 | 2 | 2 |
2 | 12 | 1179.36 | 5 | 15.21 | 1850 | 141 | 0.37 / 666.03 | 2 | 2 |
3 | 7 | 2005.08 | 34 | 14.82 | 2737 | 1379 | 1.75 / 667.41 | 2 | 2 |
4 | 13 | 1592.08 | 22 | 14.82 | 2292 | 747 | 2.50 / 668.15 | 2 | 3 |
5 | 13 | 1002.24 | 22 | 14.86 | 1611 | 527 | 3.03 / 668.68 | 2 | 3 |
6 | 13 | 377.92 | 22 | 14.96 | 852 | 280 | 3.31 / 668.96 | 2 | 3 |
7 | 13 | 133.08 | 22 | 15.02 | 486 | 161 | 3.47 / 669.12 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.02 | 298 | 783 | 4.25 / 669.90 | 2 | 7 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 36 | 14.97 | 433 | 233 | 0.23 / 661.76 | 2 | 2 |
2 | 12 | 1175.76 | 5 | 15.20 | 1849 | 141 | 0.37 / 661.90 | 2 | 2 |
3 | 7 | 2003.48 | 34 | 14.83 | 2737 | 1380 | 1.75 / 663.28 | 2 | 2 |
4 | 13 | 1469.48 | 22 | 14.84 | 2151 | 702 | 2.46 / 663.98 | 2 | 3 |
5 | 13 | 914.28 | 22 | 14.86 | 1509 | 493 | 2.95 / 664.47 | 2 | 3 |
6 | 13 | 314.96 | 22 | 14.97 | 762 | 251 | 3.20 / 664.72 | 2 | 3 |
7 | 13 | 113.16 | 22 | 15.02 | 473 | 156 | 3.36 / 664.88 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.02 | 294 | 773 | 4.13 / 665.65 | 2 | 8 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 36 | 14.99 | 423 | 228 | 0.23 / 657.57 | 2 | 2 |
2 | 12 | 1167.92 | 5 | 15.21 | 1843 | 140 | 0.37 / 657.71 | 2 | 2 |
3 | 7 | 2004.64 | 34 | 14.82 | 2746 | 1384 | 1.75 / 659.10 | 2 | 2 |
4 | 13 | 1480.04 | 22 | 14.83 | 2184 | 713 | 2.46 / 659.81 | 2 | 3 |
5 | 13 | 919.12 | 22 | 14.86 | 1516 | 496 | 2.96 / 660.31 | 2 | 3 |
6 | 13 | 327.40 | 22 | 14.96 | 793 | 261 | 3.22 / 660.57 | 2 | 3 |
7 | 13 | 103.76 | 22 | 15.02 | 467 | 154 | 3.38 / 660.72 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.01 | 305 | 801 | 4.18 / 661.52 | 2 | 9 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 36 | 15.00 | 415 | 224 | 0.22 / 653.30 | 2 | 2 |
2 | 12 | 1172.40 | 5 | 15.21 | 1836 | 140 | 0.36 / 653.44 | 2 | 2 |
3 | 7 | 2006.00 | 34 | 14.82 | 2740 | 1381 | 1.74 / 654.82 | 2 | 3 |
4 | 13 | 1586.12 | 22 | 14.82 | 2319 | 756 | 2.50 / 655.57 | 2 | 3 |
5 | 13 | 987.84 | 22 | 14.85 | 1603 | 524 | 3.02 / 656.10 | 2 | 3 |
6 | 13 | 371.64 | 22 | 14.95 | 856 | 282 | 3.31 / 656.38 | 2 | 3 |
7 | 13 | 126.56 | 22 | 15.02 | 499 | 165 | 3.47 / 656.54 | 2 | 3 |
8 | 8 | 0.08 | 175 | 15.01 | 306 | 804 | 4.27 / 657.35 | 2 | 6 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 36 | 14.99 | 422 | 228 | 0.23 / 649.13 | 2 | 2 |
2 | 12 | 1173.04 | 5 | 15.21 | 1847 | 140 | 0.37 / 649.27 | 2 | 2 |
3 | 7 | 2003.64 | 34 | 14.82 | 2749 | 1385 | 1.75 / 650.66 | 2 | 2 |
4 | 13 | 1584.40 | 22 | 14.82 | 2286 | 745 | 2.50 / 651.41 | 2 | 3 |
5 | 13 | 878.72 | 22 | 14.87 | 1483 | 485 | 2.98 / 651.89 | 2 | 2 |
6 | 13 | 289.84 | 22 | 14.98 | 726 | 239 | 3.22 / 652.13 | 2 | 3 |
7 | 13 | 111.72 | 22 | 15.03 | 466 | 154 | 3.38 / 652.28 | 2 | 2 |
8 | 8 | 0.00 | 175 | 15.02 | 300 | 789 | 4.17 / 653.07 | 2 | 10 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 36 | 15.00 | 429 | 232 | 0.23 / 645.00 | 2 | 2 |
2 | 12 | 1164.24 | 5 | 15.20 | 1832 | 139 | 0.37 / 645.14 | 2 | 2 |
3 | 7 | 2004.04 | 34 | 14.83 | 2746 | 1385 | 1.76 / 646.52 | 2 | 2 |
4 | 13 | 1468.08 | 22 | 14.84 | 2156 | 704 | 2.46 / 647.22 | 2 | 3 |
5 | 13 | 889.76 | 22 | 14.87 | 1489 | 487 | 2.95 / 647.71 | 2 | 3 |
6 | 13 | 303.32 | 22 | 14.98 | 743 | 245 | 3.19 / 647.96 | 2 | 3 |
7 | 13 | 120.56 | 22 | 15.02 | 481 | 159 | 3.35 / 648.12 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.02 | 301 | 791 | 4.14 / 648.91 | 2 | 8 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 36 | 15.00 | 420 | 227 | 0.23 / 640.85 | 2 | 2 |
2 | 12 | 1172.52 | 5 | 15.20 | 1873 | 142 | 0.37 / 640.99 | 2 | 2 |
3 | 7 | 2001.88 | 34 | 14.82 | 2760 | 1391 | 1.76 / 642.38 | 2 | 2 |
4 | 13 | 1577.96 | 22 | 14.82 | 2292 | 747 | 2.51 / 643.13 | 2 | 3 |
5 | 13 | 845.76 | 22 | 14.88 | 1438 | 471 | 2.98 / 643.60 | 2 | 3 |
6 | 13 | 275.68 | 22 | 14.99 | 730 | 241 | 3.22 / 643.84 | 2 | 3 |
7 | 13 | 103.52 | 22 | 15.03 | 455 | 150 | 3.37 / 643.99 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.03 | 293 | 771 | 4.14 / 644.76 | 2 | 7 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 36 | 15.00 | 418 | 226 | 0.23 / 636.68 | 2 | 2 |
2 | 12 | 1181.56 | 5 | 15.21 | 1862 | 142 | 0.37 / 636.82 | 2 | 2 |
3 | 7 | 2007.40 | 34 | 14.83 | 2762 | 1393 | 1.76 / 638.21 | 2 | 2 |
4 | 13 | 1590.44 | 22 | 14.82 | 2310 | 753 | 2.51 / 638.97 | 2 | 3 |
5 | 13 | 877.76 | 22 | 14.88 | 1464 | 479 | 2.99 / 639.45 | 2 | 3 |
6 | 13 | 301.44 | 22 | 14.98 | 743 | 245 | 3.24 / 639.69 | 2 | 3 |
7 | 13 | 109.28 | 22 | 15.03 | 464 | 153 | 3.39 / 639.84 | 2 | 2 |
8 | 8 | 0.00 | 175 | 15.02 | 297 | 781 | 4.17 / 640.63 | 2 | 6 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 36 | 15.00 | 413 | 223 | 0.22 / 632.53 | 2 | 2 |
2 | 12 | 1179.68 | 5 | 15.21 | 1864 | 142 | 0.36 / 632.67 | 2 | 2 |
3 | 7 | 2005.48 | 35 | 14.81 | 2746 | 1423 | 1.79 / 634.09 | 2 | 2 |
4 | 13 | 1456.20 | 22 | 14.83 | 2160 | 705 | 2.49 / 634.80 | 2 | 3 |
5 | 13 | 885.48 | 22 | 14.88 | 1471 | 482 | 2.97 / 635.28 | 2 | 3 |
6 | 13 | 276.92 | 22 | 14.99 | 716 | 236 | 3.21 / 635.51 | 2 | 3 |
7 | 13 | 102.12 | 22 | 15.04 | 453 | 150 | 3.36 / 635.66 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.02 | 301 | 791 | 4.15 / 636.45 | 2 | 10 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 36 | 14.99 | 421 | 227 | 0.23 / 628.41 | 2 | 2 |
2 | 12 | 1167.12 | 5 | 15.21 | 1826 | 139 | 0.37 / 628.55 | 2 | 2 |
3 | 7 | 2003.92 | 34 | 14.83 | 2732 | 1378 | 1.74 / 629.92 | 2 | 3 |
4 | 13 | 1453.92 | 22 | 14.84 | 2136 | 697 | 2.44 / 630.62 | 2 | 3 |
5 | 13 | 908.28 | 22 | 14.88 | 1489 | 487 | 2.93 / 631.11 | 2 | 3 |
6 | 13 | 315.00 | 22 | 14.98 | 776 | 256 | 3.18 / 631.36 | 2 | 3 |
7 | 13 | 114.40 | 22 | 15.03 | 464 | 153 | 3.34 / 631.52 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.03 | 298 | 784 | 4.12 / 632.30 | 2 | 7 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 36 | 15.01 | 412 | 223 | 0.22 / 624.16 | 2 | 2 |
2 | 12 | 1171.68 | 5 | 15.22 | 1835 | 140 | 0.36 / 624.30 | 2 | 2 |
3 | 7 | 2003.32 | 34 | 14.83 | 2732 | 1378 | 1.74 / 625.68 | 2 | 2 |
4 | 13 | 1462.28 | 22 | 14.84 | 2162 | 706 | 2.45 / 626.38 | 2 | 4 |
5 | 13 | 886.12 | 22 | 14.88 | 1486 | 486 | 2.93 / 626.87 | 2 | 3 |
6 | 13 | 290.48 | 22 | 14.98 | 745 | 246 | 3.18 / 627.12 | 2 | 3 |
7 | 13 | 89.72 | 22 | 15.03 | 458 | 151 | 3.33 / 627.27 | 2 | 2 |
8 | 13 | 21.80 | 22 | 15.04 | 356 | 118 | 3.45 / 627.38 | 2 | 2 |
9 | 8 | 0.12 | 175 | 15.01 | 303 | 796 | 4.24 / 628.18 | 2 | 8 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 36 | 15.00 | 420 | 227 | 0.23 / 619.95 | 2 | 2 |
2 | 12 | 1156.92 | 5 | 15.21 | 1826 | 139 | 0.37 / 620.09 | 2 | 2 |
3 | 7 | 2004.96 | 34 | 14.83 | 2753 | 1388 | 1.75 / 621.48 | 2 | 2 |
4 | 13 | 1460.20 | 22 | 14.84 | 2154 | 703 | 2.46 / 622.18 | 2 | 3 |
5 | 13 | 1168.12 | 22 | 14.83 | 1808 | 590 | 3.05 / 622.77 | 2 | 3 |
6 | 13 | 274.08 | 22 | 15.00 | 707 | 233 | 3.28 / 623.01 | 2 | 3 |
7 | 13 | 104.68 | 22 | 15.04 | 466 | 154 | 3.43 / 623.16 | 2 | 2 |
8 | 8 | 0.04 | 175 | 15.03 | 295 | 776 | 4.21 / 623.94 | 2 | 6 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 35 | 15.00 | 426 | 224 | 0.22 / 615.80 | 2 | 2 |
2 | 12 | 1160.64 | 5 | 15.21 | 1818 | 138 | 0.36 / 615.94 | 2 | 2 |
3 | 7 | 2002.80 | 34 | 14.83 | 2745 | 1384 | 1.75 / 617.32 | 2 | 3 |
4 | 13 | 1457.40 | 22 | 14.84 | 2144 | 700 | 2.45 / 618.02 | 2 | 3 |
5 | 13 | 908.92 | 22 | 14.87 | 1510 | 494 | 2.94 / 618.52 | 2 | 3 |
6 | 13 | 329.00 | 22 | 14.98 | 788 | 260 | 3.20 / 618.78 | 2 | 3 |
7 | 13 | 110.84 | 22 | 15.03 | 477 | 158 | 3.36 / 618.94 | 2 | 3 |
8 | 8 | 0.08 | 175 | 15.03 | 301 | 792 | 4.15 / 619.73 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.64 | 35 | 14.99 | 422 | 221 | 0.22 / 611.60 | 2 | 2 |
2 | 12 | 1175.56 | 5 | 15.21 | 1875 | 143 | 0.36 / 611.75 | 2 | 2 |
3 | 7 | 2006.36 | 34 | 14.83 | 2755 | 1389 | 1.75 / 613.13 | 2 | 3 |
4 | 13 | 1565.08 | 22 | 14.83 | 2280 | 744 | 2.50 / 613.88 | 2 | 3 |
5 | 13 | 973.92 | 22 | 14.87 | 1573 | 515 | 3.01 / 614.39 | 2 | 3 |
6 | 13 | 249.20 | 22 | 15.01 | 671 | 222 | 3.23 / 614.61 | 2 | 3 |
7 | 13 | 129.68 | 22 | 15.04 | 504 | 167 | 3.40 / 614.78 | 2 | 3 |
8 | 8 | 0.24 | 175 | 15.03 | 303 | 797 | 4.20 / 615.58 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 36 | 15.00 | 421 | 227 | 0.23 / 607.38 | 2 | 2 |
2 | 12 | 1163.24 | 5 | 15.22 | 1838 | 140 | 0.37 / 607.52 | 2 | 2 |
3 | 7 | 2006.80 | 34 | 14.83 | 2737 | 1380 | 1.75 / 608.90 | 2 | 3 |
4 | 13 | 1464.68 | 22 | 14.85 | 2157 | 705 | 2.45 / 609.60 | 2 | 3 |
5 | 13 | 896.48 | 22 | 14.88 | 1474 | 483 | 2.93 / 610.09 | 2 | 3 |
6 | 13 | 304.08 | 22 | 14.99 | 767 | 253 | 3.19 / 610.34 | 2 | 3 |
7 | 13 | 96.20 | 22 | 15.04 | 442 | 146 | 3.33 / 610.49 | 2 | 3 |
8 | 13 | 22.84 | 22 | 15.05 | 349 | 116 | 3.45 / 610.60 | 2 | 3 |
9 | 8 | 0.04 | 175 | 15.02 | 297 | 781 | 4.23 / 611.38 | 2 | 10 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 36 | 15.01 | 417 | 225 | 0.23 / 603.16 | 2 | 2 |
2 | 12 | 1170.56 | 5 | 15.21 | 1853 | 141 | 0.37 / 603.30 | 2 | 2 |
3 | 7 | 2002.88 | 34 | 14.83 | 2766 | 1395 | 1.76 / 604.69 | 2 | 3 |
4 | 13 | 1574.72 | 22 | 14.83 | 2276 | 743 | 2.50 / 605.44 | 2 | 3 |
5 | 13 | 976.88 | 22 | 14.87 | 1576 | 516 | 3.02 / 605.95 | 2 | 3 |
6 | 13 | 260.28 | 22 | 15.00 | 705 | 233 | 3.25 / 606.18 | 2 | 3 |
7 | 13 | 139.80 | 22 | 15.03 | 509 | 168 | 3.42 / 606.35 | 2 | 3 |
8 | 8 | 0.08 | 175 | 15.03 | 304 | 800 | 4.22 / 607.15 | 2 | 12 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 36 | 15.01 | 418 | 226 | 0.23 / 598.94 | 2 | 2 |
2 | 12 | 1166.60 | 5 | 15.21 | 1844 | 140 | 0.37 / 599.08 | 2 | 2 |
3 | 7 | 2001.24 | 34 | 14.83 | 2759 | 1391 | 1.76 / 600.48 | 2 | 3 |
4 | 13 | 1596.48 | 22 | 14.82 | 2313 | 754 | 2.51 / 601.23 | 2 | 3 |
5 | 13 | 888.88 | 22 | 14.88 | 1492 | 488 | 3.00 / 601.72 | 2 | 3 |
6 | 13 | 320.80 | 22 | 14.98 | 783 | 258 | 3.26 / 601.98 | 2 | 3 |
7 | 13 | 122.00 | 22 | 15.04 | 488 | 161 | 3.42 / 602.14 | 2 | 2 |
8 | 8 | 0.20 | 175 | 15.03 | 302 | 794 | 4.21 / 602.93 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 36 | 15.01 | 412 | 223 | 0.22 / 594.81 | 2 | 2 |
2 | 12 | 1147.44 | 5 | 15.21 | 1827 | 139 | 0.36 / 594.95 | 2 | 2 |
3 | 7 | 2005.36 | 34 | 14.83 | 2749 | 1386 | 1.75 / 596.33 | 2 | 3 |
4 | 13 | 1454.84 | 22 | 14.85 | 2137 | 698 | 2.45 / 597.03 | 2 | 3 |
5 | 13 | 906.32 | 22 | 14.88 | 1492 | 488 | 2.93 / 597.52 | 2 | 3 |
6 | 13 | 324.20 | 22 | 14.98 | 791 | 261 | 3.19 / 597.78 | 2 | 3 |
7 | 13 | 118.52 | 22 | 15.04 | 476 | 157 | 3.35 / 597.94 | 2 | 2 |
8 | 8 | 0.20 | 175 | 15.03 | 297 | 781 | 4.13 / 598.72 | 2 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 36 | 15.00 | 431 | 233 | 0.23 / 590.60 | 2 | 2 |
2 | 12 | 1179.16 | 5 | 15.21 | 1842 | 140 | 0.37 / 590.74 | 2 | 2 |
3 | 7 | 2001.04 | 34 | 14.83 | 2742 | 1383 | 1.76 / 592.12 | 2 | 2 |
4 | 13 | 1570.36 | 22 | 14.83 | 2282 | 745 | 2.50 / 592.87 | 2 | 3 |
5 | 13 | 973.56 | 22 | 14.87 | 1581 | 517 | 3.02 / 593.39 | 2 | 2 |
6 | 13 | 256.44 | 22 | 15.01 | 697 | 230 | 3.25 / 593.62 | 2 | 2 |
7 | 13 | 136.44 | 22 | 15.03 | 521 | 172 | 3.42 / 593.79 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.04 | 303 | 797 | 4.22 / 594.58 | 2 | 7 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 36 | 15.01 | 421 | 227 | 0.23 / 586.31 | 2 | 2 |
2 | 12 | 1176.88 | 5 | 15.21 | 1832 | 139 | 0.37 / 586.45 | 2 | 2 |
3 | 7 | 2003.28 | 34 | 14.83 | 2746 | 1385 | 1.75 / 587.83 | 2 | 2 |
4 | 13 | 1466.24 | 22 | 14.85 | 2167 | 708 | 2.46 / 588.54 | 2 | 2 |
5 | 13 | 910.52 | 22 | 14.88 | 1506 | 493 | 2.95 / 589.03 | 2 | 2 |
6 | 13 | 321.36 | 22 | 14.99 | 774 | 255 | 3.21 / 589.29 | 2 | 3 |
7 | 13 | 117.80 | 22 | 15.04 | 492 | 163 | 3.37 / 589.45 | 2 | 2 |
8 | 13 | 28.08 | 22 | 15.06 | 358 | 119 | 3.49 / 589.57 | 2 | 2 |
9 | 8 | 0.08 | 175 | 15.03 | 303 | 797 | 4.29 / 590.37 | 2 | 8 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 36 | 15.01 | 414 | 224 | 0.22 / 582.17 | 2 | 2 |
2 | 12 | 1161.60 | 5 | 15.22 | 1850 | 141 | 0.36 / 582.31 | 2 | 2 |
3 | 7 | 2005.64 | 35 | 14.82 | 2760 | 1432 | 1.80 / 583.75 | 2 | 2 |
4 | 13 | 1451.92 | 22 | 14.85 | 2152 | 703 | 2.50 / 584.45 | 2 | 2 |
5 | 13 | 879.44 | 22 | 14.89 | 1476 | 484 | 2.98 / 584.93 | 2 | 2 |
6 | 13 | 203.72 | 22 | 15.03 | 609 | 201 | 3.18 / 585.13 | 2 | 2 |
7 | 13 | 126.80 | 22 | 15.05 | 488 | 162 | 3.35 / 585.29 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.04 | 299 | 787 | 4.13 / 586.08 | 2 | 7 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 36 | 15.02 | 421 | 228 | 0.23 / 577.86 | 2 | 2 |
2 | 12 | 1167.04 | 5 | 15.22 | 1825 | 139 | 0.37 / 578.00 | 2 | 2 |
3 | 7 | 2002.92 | 34 | 14.84 | 2739 | 1382 | 1.75 / 579.39 | 2 | 2 |
4 | 13 | 1723.64 | 22 | 14.82 | 2443 | 797 | 2.55 / 580.18 | 2 | 2 |
5 | 13 | 949.32 | 22 | 14.88 | 1549 | 507 | 3.05 / 580.69 | 2 | 2 |
6 | 13 | 496.24 | 22 | 14.95 | 991 | 326 | 3.38 / 581.01 | 2 | 3 |
7 | 13 | 128.92 | 22 | 15.04 | 478 | 158 | 3.54 / 581.17 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.04 | 295 | 776 | 4.31 / 581.95 | 2 | 7 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 36 | 15.03 | 417 | 226 | 0.23 / 573.68 | 2 | 2 |
2 | 12 | 1173.20 | 5 | 15.21 | 1870 | 142 | 0.37 / 573.82 | 2 | 2 |
3 | 7 | 2002.32 | 34 | 14.83 | 2771 | 1397 | 1.77 / 575.22 | 2 | 2 |
4 | 13 | 1461.28 | 22 | 14.84 | 2167 | 707 | 2.47 / 575.93 | 2 | 2 |
5 | 13 | 1018.24 | 22 | 14.86 | 1637 | 535 | 3.01 / 576.46 | 2 | 2 |
6 | 13 | 283.52 | 22 | 15.00 | 725 | 239 | 3.25 / 576.70 | 2 | 3 |
7 | 13 | 113.08 | 22 | 15.05 | 465 | 154 | 3.40 / 576.86 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.04 | 296 | 779 | 4.18 / 577.64 | 2 | 5 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 36 | 15.02 | 425 | 230 | 0.23 / 569.53 | 2 | 2 |
2 | 12 | 1169.72 | 5 | 15.22 | 1838 | 140 | 0.37 / 569.67 | 2 | 2 |
3 | 7 | 2002.48 | 34 | 14.85 | 2731 | 1379 | 1.75 / 571.05 | 2 | 2 |
4 | 13 | 1462.32 | 22 | 14.85 | 2144 | 700 | 2.45 / 571.75 | 2 | 2 |
5 | 13 | 1027.20 | 22 | 14.87 | 1646 | 538 | 2.99 / 572.29 | 2 | 3 |
6 | 13 | 279.48 | 22 | 15.01 | 724 | 239 | 3.23 / 572.53 | 2 | 3 |
7 | 13 | 116.52 | 22 | 15.06 | 468 | 155 | 3.38 / 572.69 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.05 | 293 | 772 | 4.15 / 573.46 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 36 | 15.02 | 422 | 228 | 0.23 / 565.32 | 2 | 2 |
2 | 12 | 1171.32 | 5 | 15.22 | 1871 | 142 | 0.37 / 565.46 | 2 | 2 |
3 | 7 | 2002.24 | 34 | 14.84 | 2755 | 1390 | 1.76 / 566.85 | 2 | 2 |
4 | 13 | 1577.24 | 22 | 14.83 | 2289 | 747 | 2.51 / 567.60 | 2 | 2 |
5 | 13 | 976.28 | 22 | 14.88 | 1583 | 518 | 3.03 / 568.11 | 2 | 2 |
6 | 13 | 262.64 | 22 | 15.02 | 699 | 231 | 3.26 / 568.34 | 2 | 2 |
7 | 13 | 139.00 | 22 | 15.04 | 511 | 169 | 3.43 / 568.51 | 2 | 2 |
8 | 8 | 0.04 | 175 | 15.04 | 300 | 790 | 4.22 / 569.30 | 2 | 8 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 35 | 15.01 | 431 | 226 | 0.23 / 561.17 | 2 | 2 |
2 | 12 | 1173.40 | 5 | 15.21 | 1862 | 142 | 0.37 / 561.31 | 2 | 2 |
3 | 7 | 2004.64 | 34 | 14.83 | 2760 | 1392 | 1.76 / 562.70 | 2 | 2 |
4 | 13 | 1449.88 | 22 | 14.85 | 2140 | 699 | 2.46 / 563.40 | 2 | 3 |
5 | 13 | 885.00 | 22 | 14.89 | 1486 | 487 | 2.95 / 563.88 | 2 | 3 |
6 | 13 | 306.00 | 22 | 15.00 | 754 | 249 | 3.19 / 564.13 | 2 | 3 |
7 | 13 | 112.68 | 22 | 15.05 | 480 | 159 | 3.35 / 564.29 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.05 | 302 | 795 | 4.15 / 565.09 | 2 | 8 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.64 | 35 | 15.02 | 421 | 221 | 0.22 / 556.88 | 2 | 2 |
2 | 12 | 1166.56 | 5 | 15.22 | 1842 | 140 | 0.36 / 557.02 | 2 | 2 |
3 | 7 | 2004.40 | 34 | 14.83 | 2758 | 1391 | 1.75 / 558.41 | 2 | 2 |
4 | 13 | 1578.76 | 22 | 14.83 | 2296 | 749 | 2.50 / 559.16 | 2 | 2 |
5 | 13 | 983.72 | 22 | 14.87 | 1598 | 523 | 3.02 / 559.68 | 2 | 3 |
6 | 13 | 370.16 | 22 | 14.98 | 842 | 277 | 3.30 / 559.96 | 2 | 3 |
7 | 13 | 125.48 | 22 | 15.04 | 507 | 168 | 3.47 / 560.12 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.04 | 310 | 816 | 4.29 / 560.94 | 2 | 9 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.72 | 35 | 15.04 | 415 | 218 | 0.22 / 552.63 | 2 | 2 |
2 | 12 | 1177.12 | 5 | 15.22 | 1852 | 141 | 0.36 / 552.77 | 2 | 2 |
3 | 7 | 2002.76 | 35 | 14.83 | 2775 | 1440 | 1.80 / 554.21 | 2 | 2 |
4 | 13 | 1572.24 | 22 | 14.83 | 2314 | 755 | 2.55 / 554.97 | 2 | 2 |
5 | 13 | 962.20 | 22 | 14.88 | 1584 | 519 | 3.07 / 555.49 | 2 | 2 |
6 | 13 | 246.12 | 22 | 15.02 | 672 | 222 | 3.30 / 555.71 | 2 | 2 |
7 | 13 | 126.76 | 22 | 15.05 | 492 | 163 | 3.46 / 555.87 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.05 | 297 | 782 | 4.24 / 556.65 | 2 | 8 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 35 | 15.03 | 416 | 219 | 0.22 / 548.39 | 2 | 2 |
2 | 12 | 1163.64 | 5 | 15.23 | 1825 | 139 | 0.36 / 548.53 | 2 | 2 |
3 | 7 | 2004.40 | 34 | 14.84 | 2747 | 1386 | 1.74 / 549.92 | 2 | 2 |
4 | 13 | 1598.60 | 22 | 14.83 | 2317 | 756 | 2.50 / 550.67 | 2 | 2 |
5 | 13 | 869.20 | 22 | 14.90 | 1469 | 482 | 2.98 / 551.15 | 2 | 3 |
6 | 13 | 287.44 | 22 | 15.01 | 747 | 247 | 3.23 / 551.40 | 2 | 3 |
7 | 13 | 111.24 | 22 | 15.06 | 475 | 157 | 3.39 / 551.56 | 2 | 2 |
8 | 8 | 0.04 | 175 | 15.05 | 299 | 787 | 4.17 / 552.34 | 2 | 10 |
9 | 14 | 0.04 | 15 | 15.03 | 305 | 69 | 4.24 / 552.41 | 2 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 35 | 15.02 | 432 | 227 | 0.23 / 544.16 | 2 | 2 |
2 | 12 | 1156.96 | 5 | 15.23 | 1824 | 139 | 0.37 / 544.30 | 2 | 2 |
3 | 7 | 2003.68 | 34 | 14.84 | 2743 | 1384 | 1.75 / 545.68 | 2 | 2 |
4 | 13 | 1585.44 | 22 | 14.84 | 2286 | 746 | 2.50 / 546.43 | 2 | 2 |
5 | 13 | 979.96 | 22 | 14.88 | 1590 | 521 | 3.02 / 546.95 | 2 | 3 |
6 | 13 | 371.48 | 22 | 14.99 | 841 | 277 | 3.29 / 547.23 | 2 | 3 |
7 | 13 | 135.28 | 22 | 15.05 | 505 | 167 | 3.46 / 547.39 | 2 | 3 |
8 | 8 | 0.20 | 175 | 15.05 | 296 | 780 | 4.24 / 548.17 | 2 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 35 | 15.02 | 423 | 222 | 0.22 / 539.96 | 2 | 2 |
2 | 12 | 1184.52 | 5 | 15.21 | 1883 | 143 | 0.37 / 540.11 | 2 | 2 |
3 | 7 | 2001.76 | 35 | 14.83 | 2750 | 1427 | 1.79 / 541.53 | 2 | 2 |
4 | 13 | 1573.52 | 21 | 14.84 | 2273 | 708 | 2.50 / 542.24 | 2 | 2 |
5 | 13 | 971.60 | 21 | 14.88 | 1599 | 500 | 3.00 / 542.74 | 2 | 3 |
6 | 13 | 262.92 | 21 | 15.02 | 701 | 221 | 3.22 / 542.96 | 2 | 3 |
7 | 13 | 139.08 | 21 | 15.05 | 513 | 162 | 3.38 / 543.13 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.05 | 306 | 806 | 4.19 / 543.93 | 2 | 6 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 35 | 15.03 | 415 | 218 | 0.22 / 535.77 | 2 | 2 |
2 | 12 | 1186.52 | 5 | 15.22 | 1865 | 142 | 0.36 / 535.91 | 2 | 2 |
3 | 7 | 2002.68 | 35 | 14.83 | 2741 | 1423 | 1.78 / 537.33 | 2 | 2 |
4 | 13 | 1339.64 | 21 | 14.87 | 2012 | 628 | 2.41 / 537.96 | 2 | 2 |
5 | 13 | 1054.24 | 21 | 14.86 | 1695 | 529 | 2.94 / 538.49 | 2 | 3 |
6 | 13 | 294.48 | 21 | 15.01 | 732 | 231 | 3.17 / 538.72 | 2 | 3 |
7 | 13 | 118.20 | 21 | 15.06 | 473 | 150 | 3.32 / 538.87 | 2 | 3 |
8 | 13 | 32.44 | 21 | 15.08 | 346 | 110 | 3.43 / 538.98 | 2 | 2 |
9 | 8 | 0.12 | 175 | 15.05 | 290 | 764 | 4.19 / 539.74 | 2 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 35 | 15.03 | 429 | 226 | 0.23 / 531.67 | 2 | 2 |
2 | 12 | 1173.36 | 5 | 15.23 | 1838 | 140 | 0.37 / 531.81 | 2 | 2 |
3 | 7 | 2005.92 | 35 | 14.84 | 2743 | 1425 | 1.79 / 533.23 | 2 | 2 |
4 | 13 | 1463.20 | 21 | 14.85 | 2162 | 674 | 2.46 / 533.90 | 2 | 2 |
5 | 13 | 895.96 | 21 | 14.89 | 1497 | 468 | 2.93 / 534.37 | 2 | 2 |
6 | 13 | 316.28 | 21 | 15.00 | 768 | 242 | 3.17 / 534.61 | 2 | 3 |
7 | 13 | 128.16 | 21 | 15.06 | 490 | 155 | 3.33 / 534.77 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.06 | 295 | 777 | 4.11 / 535.55 | 2 | 7 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.16 | 35 | 15.03 | 435 | 229 | 0.23 / 527.47 | 2 | 2 |
2 | 12 | 1170.40 | 5 | 15.22 | 1837 | 140 | 0.37 / 527.61 | 2 | 2 |
3 | 7 | 2006.60 | 35 | 14.84 | 2747 | 1427 | 1.80 / 529.04 | 2 | 2 |
4 | 13 | 1458.44 | 21 | 14.86 | 2146 | 670 | 2.47 / 529.71 | 2 | 2 |
5 | 13 | 889.00 | 21 | 14.90 | 1492 | 467 | 2.93 / 530.17 | 2 | 3 |
6 | 13 | 299.96 | 21 | 15.01 | 754 | 238 | 3.17 / 530.41 | 2 | 3 |
7 | 13 | 126.08 | 21 | 15.07 | 482 | 153 | 3.32 / 530.56 | 2 | 2 |
8 | 13 | 31.84 | 21 | 15.09 | 345 | 109 | 3.43 / 530.67 | 2 | 2 |
9 | 8 | 0.04 | 175 | 15.06 | 291 | 767 | 4.20 / 531.44 | 2 | 6 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 35 | 15.02 | 423 | 222 | 0.22 / 523.24 | 2 | 2 |
2 | 12 | 1168.60 | 5 | 15.22 | 1846 | 140 | 0.36 / 523.38 | 2 | 2 |
3 | 7 | 2001.84 | 35 | 14.83 | 2753 | 1429 | 1.79 / 524.81 | 2 | 2 |
4 | 13 | 1581.96 | 21 | 14.83 | 2303 | 717 | 2.51 / 525.53 | 2 | 2 |
5 | 13 | 973.20 | 21 | 14.89 | 1576 | 493 | 3.00 / 526.02 | 2 | 3 |
6 | 13 | 369.76 | 21 | 15.00 | 837 | 264 | 3.27 / 526.29 | 2 | 3 |
7 | 13 | 131.32 | 21 | 15.06 | 506 | 160 | 3.43 / 526.45 | 2 | 3 |
8 | 8 | 0.12 | 175 | 15.06 | 302 | 796 | 4.22 / 527.24 | 2 | 7 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 35 | 15.01 | 441 | 232 | 0.23 / 518.84 | 2 | 2 |
2 | 12 | 1180.84 | 5 | 15.22 | 1855 | 141 | 0.37 / 518.98 | 2 | 2 |
3 | 7 | 2000.32 | 37 | 14.83 | 2739 | 1503 | 1.88 / 520.49 | 2 | 2 |
4 | 13 | 1487.20 | 31 | 14.82 | 2173 | 998 | 2.87 / 521.49 | 2 | 2 |
5 | 13 | 551.00 | 31 | 14.95 | 1079 | 500 | 3.37 / 521.99 | 2 | 3 |
6 | 13 | 117.72 | 31 | 15.06 | 490 | 229 | 3.60 / 522.21 | 2 | 3 |
7 | 8 | -0.04 | 175 | 15.05 | 306 | 806 | 4.41 / 523.02 | 2 | 8 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.72 | 35 | 15.02 | 432 | 227 | 0.23 / 514.37 | 2 | 2 |
2 | 3 | 1014.36 | 1 | 15.24 | 1682 | 26 | 0.25 / 514.39 | 2 | 2 |
3 | 12 | 1169.12 | 5 | 15.23 | 1870 | 142 | 0.40 / 514.54 | 2 | 2 |
4 | 7 | 2005.32 | 38 | 14.82 | 2761 | 1555 | 1.95 / 516.09 | 2 | 2 |
5 | 13 | 1328.80 | 31 | 14.85 | 1996 | 919 | 2.87 / 517.01 | 2 | 2 |
6 | 13 | 609.84 | 31 | 14.93 | 1155 | 535 | 3.40 / 517.54 | 2 | 3 |
7 | 13 | 125.92 | 31 | 15.05 | 506 | 236 | 3.64 / 517.78 | 2 | 3 |
8 | 8 | 0.08 | 175 | 15.04 | 316 | 832 | 4.47 / 518.61 | 2 | 9 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.64 | 35 | 15.02 | 433 | 228 | 0.23 / 509.93 | 2 | 2 |
2 | 12 | 1177.56 | 5 | 15.23 | 1861 | 142 | 0.37 / 510.07 | 2 | 2 |
3 | 7 | 2005.72 | 37 | 14.83 | 2749 | 1508 | 1.88 / 511.58 | 2 | 2 |
4 | 13 | 1502.04 | 31 | 14.82 | 2201 | 1011 | 2.89 / 512.59 | 2 | 2 |
5 | 13 | 559.16 | 31 | 14.95 | 1081 | 501 | 3.39 / 513.09 | 2 | 3 |
6 | 13 | 119.96 | 31 | 15.06 | 488 | 228 | 3.62 / 513.32 | 2 | 3 |
7 | 8 | 0.16 | 175 | 15.05 | 311 | 819 | 4.44 / 514.14 | 2 | 11 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 35 | 15.03 | 433 | 228 | 0.23 / 505.34 | 2 | 2 |
2 | 12 | 1167.72 | 5 | 15.23 | 1868 | 142 | 0.37 / 505.48 | 2 | 2 |
3 | 7 | 2006.52 | 47 | 14.78 | 2767 | 1922 | 2.29 / 507.40 | 2 | 2 |
4 | 13 | 1271.08 | 31 | 14.83 | 1937 | 890 | 3.18 / 508.29 | 2 | 2 |
5 | 13 | 318.56 | 31 | 15.01 | 789 | 367 | 3.55 / 508.66 | 2 | 3 |
6 | 13 | 82.28 | 31 | 15.07 | 441 | 206 | 3.76 / 508.86 | 2 | 3 |
7 | 8 | -0.12 | 175 | 15.04 | 319 | 840 | 4.60 / 509.70 | 2 | 13 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 35 | 15.02 | 434 | 228 | 0.23 / 500.78 | 2 | 2 |
2 | 12 | 1162.16 | 5 | 15.23 | 1840 | 140 | 0.37 / 500.92 | 2 | 2 |
3 | 7 | 2002.04 | 47 | 14.79 | 2765 | 1922 | 2.29 / 502.84 | 2 | 2 |
4 | 13 | 1232.16 | 31 | 14.85 | 1896 | 873 | 3.16 / 503.71 | 2 | 3 |
5 | 13 | 290.88 | 31 | 15.03 | 747 | 348 | 3.51 / 504.06 | 2 | 3 |
6 | 13 | 80.96 | 31 | 15.08 | 445 | 208 | 3.72 / 504.27 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.06 | 318 | 838 | 4.56 / 505.11 | 2 | 8 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 35 | 15.03 | 432 | 227 | 0.23 / 496.20 | 2 | 2 |
2 | 12 | 1181.00 | 5 | 15.22 | 1841 | 140 | 0.37 / 496.34 | 2 | 2 |
3 | 7 | 2002.04 | 48 | 14.79 | 2735 | 1942 | 2.31 / 498.28 | 2 | 2 |
4 | 13 | 1269.12 | 31 | 14.84 | 1920 | 883 | 3.19 / 499.16 | 2 | 2 |
5 | 13 | 292.20 | 31 | 15.02 | 741 | 345 | 3.54 / 499.51 | 2 | 3 |
6 | 13 | 74.88 | 31 | 15.08 | 434 | 203 | 3.74 / 499.71 | 2 | 3 |
7 | 8 | 0.04 | 175 | 15.05 | 319 | 840 | 4.58 / 500.55 | 2 | 7 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 35 | 15.01 | 438 | 230 | 0.23 / 491.75 | 2 | 2 |
2 | 12 | 1164.72 | 5 | 15.24 | 1840 | 140 | 0.37 / 491.89 | 2 | 2 |
3 | 7 | 2004.32 | 47 | 14.79 | 2755 | 1915 | 2.29 / 493.81 | 2 | 2 |
4 | 13 | 1121.44 | 31 | 14.87 | 1754 | 809 | 3.09 / 494.62 | 2 | 2 |
5 | 13 | 239.92 | 31 | 15.04 | 680 | 317 | 3.41 / 494.93 | 2 | 3 |
6 | 13 | 63.64 | 31 | 15.08 | 418 | 195 | 3.61 / 495.13 | 2 | 2 |
7 | 8 | 0.04 | 175 | 15.05 | 319 | 840 | 4.45 / 495.97 | 2 | 11 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 35 | 15.02 | 443 | 233 | 0.23 / 487.22 | 2 | 2 |
2 | 12 | 1177.36 | 5 | 15.24 | 1836 | 140 | 0.37 / 487.36 | 2 | 2 |
3 | 7 | 2004.72 | 47 | 14.79 | 2750 | 1912 | 2.28 / 489.27 | 2 | 2 |
4 | 13 | 1120.24 | 31 | 14.87 | 1745 | 804 | 3.09 / 490.08 | 2 | 3 |
5 | 13 | 369.76 | 31 | 14.99 | 847 | 394 | 3.48 / 490.47 | 2 | 3 |
6 | 13 | 85.72 | 31 | 15.06 | 458 | 214 | 3.70 / 490.68 | 2 | 3 |
7 | 8 | 0.00 | 175 | 15.04 | 319 | 840 | 4.54 / 491.52 | 2 | 13 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 35 | 15.02 | 444 | 233 | 0.23 / 482.67 | 2 | 2 |
2 | 12 | 1163.52 | 5 | 15.23 | 1859 | 142 | 0.37 / 482.81 | 2 | 2 |
3 | 7 | 2002.84 | 47 | 14.79 | 2768 | 1924 | 2.30 / 484.73 | 2 | 2 |
4 | 13 | 1115.80 | 31 | 14.87 | 1761 | 812 | 3.11 / 485.55 | 2 | 3 |
5 | 13 | 347.64 | 31 | 15.00 | 828 | 385 | 3.50 / 485.93 | 2 | 3 |
6 | 13 | 87.92 | 31 | 15.07 | 457 | 213 | 3.71 / 486.15 | 2 | 3 |
7 | 8 | 0.16 | 175 | 15.05 | 320 | 843 | 4.55 / 486.99 | 2 | 8 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 35 | 15.03 | 444 | 234 | 0.23 / 478.11 | 2 | 2 |
2 | 12 | 1163.52 | 5 | 15.23 | 1862 | 142 | 0.38 / 478.25 | 2 | 2 |
3 | 7 | 2004.28 | 48 | 14.79 | 2758 | 1958 | 2.33 / 480.21 | 2 | 2 |
4 | 13 | 1095.76 | 31 | 14.88 | 1721 | 794 | 3.13 / 481.01 | 2 | 3 |
5 | 13 | 345.84 | 31 | 15.01 | 816 | 380 | 3.51 / 481.39 | 2 | 3 |
6 | 13 | 82.52 | 31 | 15.07 | 444 | 207 | 3.71 / 481.59 | 2 | 3 |
7 | 8 | 0.04 | 175 | 15.05 | 320 | 843 | 4.56 / 482.44 | 2 | 9 |
Average= | 4.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 35 | 15.03 | 445 | 234 | 0.23 / 473.69 | 2 | 2 |
2 | 12 | 1176.88 | 5 | 15.23 | 1890 | 144 | 0.38 / 473.83 | 2 | 2 |
3 | 7 | 2005.28 | 47 | 14.79 | 2753 | 1914 | 2.29 / 475.75 | 2 | 2 |
4 | 13 | 1099.52 | 31 | 14.88 | 1738 | 802 | 3.09 / 476.55 | 2 | 3 |
5 | 13 | 218.92 | 31 | 15.05 | 651 | 304 | 3.40 / 476.85 | 2 | 3 |
6 | 13 | 66.96 | 31 | 15.09 | 418 | 196 | 3.59 / 477.05 | 2 | 3 |
7 | 8 | 0.04 | 175 | 15.06 | 315 | 830 | 4.42 / 477.88 | 2 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.56 | 35 | 15.03 | 441 | 232 | 0.23 / 469.08 | 2 | 2 |
2 | 12 | 1182.24 | 5 | 15.24 | 1849 | 141 | 0.37 / 469.22 | 2 | 2 |
3 | 7 | 2006.28 | 47 | 14.80 | 2763 | 1922 | 2.29 / 471.14 | 2 | 2 |
4 | 13 | 1272.08 | 31 | 14.85 | 1944 | 895 | 3.19 / 472.04 | 2 | 3 |
5 | 13 | 315.04 | 31 | 15.02 | 788 | 367 | 3.56 / 472.40 | 2 | 3 |
6 | 13 | 88.56 | 31 | 15.08 | 454 | 212 | 3.77 / 472.62 | 2 | 3 |
7 | 8 | 0.00 | 175 | 15.06 | 319 | 841 | 4.61 / 473.46 | 2 | 8 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 35 | 15.04 | 448 | 236 | 0.24 / 464.66 | 2 | 2 |
2 | 12 | 1186.80 | 5 | 15.23 | 1855 | 141 | 0.38 / 464.80 | 2 | 2 |
3 | 7 | 2006.12 | 47 | 14.80 | 2745 | 1909 | 2.29 / 466.71 | 2 | 2 |
4 | 13 | 1104.12 | 31 | 14.88 | 1734 | 800 | 3.09 / 467.51 | 2 | 3 |
5 | 13 | 210.32 | 31 | 15.06 | 639 | 298 | 3.38 / 467.80 | 2 | 3 |
6 | 13 | 69.68 | 31 | 15.09 | 425 | 199 | 3.58 / 468.00 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.06 | 320 | 843 | 4.43 / 468.85 | 2 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 35 | 15.04 | 437 | 230 | 0.23 / 460.20 | 2 | 2 |
2 | 12 | 1162.84 | 5 | 15.24 | 1864 | 142 | 0.37 / 460.34 | 2 | 2 |
3 | 7 | 2003.48 | 47 | 14.80 | 2767 | 1925 | 2.30 / 462.27 | 2 | 2 |
4 | 13 | 1108.48 | 31 | 14.88 | 1749 | 807 | 3.10 / 463.07 | 2 | 3 |
5 | 13 | 228.36 | 31 | 15.05 | 666 | 311 | 3.41 / 463.38 | 2 | 3 |
6 | 13 | 69.44 | 31 | 15.09 | 427 | 200 | 3.61 / 463.58 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.06 | 317 | 835 | 4.45 / 464.42 | 2 | 8 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 35 | 15.05 | 426 | 224 | 0.22 / 455.82 | 2 | 2 |
2 | 12 | 1172.92 | 5 | 15.24 | 1869 | 142 | 0.37 / 455.96 | 2 | 2 |
3 | 7 | 2001.88 | 47 | 14.80 | 2746 | 1910 | 2.28 / 457.87 | 2 | 2 |
4 | 13 | 976.84 | 31 | 14.90 | 1581 | 730 | 3.01 / 458.60 | 2 | 3 |
5 | 13 | 267.32 | 31 | 15.03 | 719 | 335 | 3.34 / 458.93 | 2 | 3 |
6 | 13 | 75.60 | 31 | 15.08 | 428 | 200 | 3.54 / 459.13 | 2 | 3 |
7 | 8 | 0.16 | 175 | 15.06 | 317 | 835 | 4.38 / 459.97 | 2 | 8 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 35 | 15.04 | 444 | 234 | 0.23 / 451.28 | 2 | 2 |
2 | 12 | 1169.56 | 5 | 15.23 | 1861 | 142 | 0.38 / 451.42 | 2 | 2 |
3 | 7 | 2003.44 | 47 | 14.80 | 2757 | 1918 | 2.29 / 453.34 | 2 | 2 |
4 | 13 | 1266.68 | 31 | 14.85 | 1934 | 890 | 3.18 / 454.23 | 2 | 3 |
5 | 13 | 309.08 | 31 | 15.03 | 760 | 354 | 3.54 / 454.58 | 2 | 3 |
6 | 13 | 81.12 | 31 | 15.09 | 426 | 199 | 3.74 / 454.78 | 2 | 3 |
7 | 8 | 0.16 | 175 | 15.07 | 308 | 812 | 4.55 / 455.59 | 2 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 35 | 15.04 | 439 | 231 | 0.23 / 446.66 | 2 | 2 |
2 | 12 | 1181.16 | 5 | 15.23 | 1877 | 143 | 0.37 / 446.80 | 2 | 2 |
3 | 7 | 2003.72 | 47 | 14.80 | 2768 | 1925 | 2.30 / 448.73 | 2 | 2 |
4 | 13 | 1262.68 | 31 | 14.85 | 1931 | 889 | 3.19 / 449.62 | 2 | 3 |
5 | 13 | 311.36 | 31 | 15.03 | 782 | 364 | 3.55 / 449.98 | 2 | 3 |
6 | 13 | 81.88 | 31 | 15.09 | 445 | 208 | 3.76 / 450.19 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.07 | 324 | 854 | 4.62 / 451.04 | 2 | 12 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 35 | 15.03 | 459 | 241 | 0.24 / 442.16 | 2 | 2 |
2 | 12 | 1169.56 | 5 | 15.24 | 1840 | 140 | 0.38 / 442.30 | 2 | 2 |
3 | 7 | 2004.40 | 48 | 14.80 | 2759 | 1960 | 2.34 / 444.26 | 2 | 2 |
4 | 13 | 1107.92 | 31 | 14.88 | 1753 | 809 | 3.15 / 445.07 | 2 | 3 |
5 | 13 | 216.96 | 31 | 15.06 | 654 | 305 | 3.46 / 445.38 | 2 | 3 |
6 | 13 | 71.28 | 31 | 15.10 | 432 | 202 | 3.66 / 445.58 | 2 | 3 |
7 | 8 | 0.16 | 175 | 15.07 | 322 | 849 | 4.51 / 446.43 | 2 | 7 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.32 | 35 | 15.05 | 418 | 220 | 0.22 / 437.59 | 2 | 2 |
2 | 12 | 1161.36 | 5 | 15.24 | 1836 | 140 | 0.36 / 437.73 | 2 | 2 |
3 | 7 | 2004.12 | 47 | 14.79 | 2744 | 1907 | 2.27 / 439.64 | 2 | 2 |
4 | 13 | 1243.48 | 31 | 14.86 | 1900 | 875 | 3.14 / 440.51 | 2 | 3 |
5 | 13 | 287.16 | 31 | 15.03 | 753 | 351 | 3.49 / 440.86 | 2 | 3 |
6 | 13 | 68.56 | 31 | 15.09 | 437 | 204 | 3.70 / 441.07 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.06 | 323 | 851 | 4.55 / 441.92 | 2 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 35 | 15.04 | 423 | 223 | 0.22 / 433.19 | 2 | 2 |
2 | 12 | 1164.40 | 5 | 15.23 | 1856 | 141 | 0.36 / 433.33 | 2 | 2 |
3 | 7 | 2004.48 | 48 | 14.80 | 2754 | 1956 | 2.32 / 435.29 | 2 | 2 |
4 | 13 | 1083.12 | 31 | 14.89 | 1714 | 791 | 3.11 / 436.08 | 2 | 3 |
5 | 13 | 212.16 | 31 | 15.07 | 616 | 288 | 3.40 / 436.37 | 2 | 3 |
6 | 13 | 112.44 | 31 | 15.09 | 464 | 217 | 3.62 / 436.58 | 2 | 3 |
7 | 8 | 0.04 | 175 | 15.08 | 299 | 789 | 4.41 / 437.37 | 2 | 8 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 35 | 15.04 | 434 | 228 | 0.23 / 428.55 | 2 | 2 |
2 | 12 | 1175.72 | 5 | 15.23 | 1876 | 143 | 0.37 / 428.69 | 2 | 2 |
3 | 7 | 2004.68 | 47 | 14.80 | 2753 | 1915 | 2.29 / 430.61 | 2 | 2 |
4 | 13 | 1277.84 | 31 | 14.85 | 1949 | 897 | 3.18 / 431.51 | 2 | 3 |
5 | 13 | 467.80 | 31 | 14.98 | 964 | 448 | 3.63 / 431.95 | 2 | 3 |
6 | 13 | 119.76 | 31 | 15.08 | 476 | 223 | 3.85 / 432.18 | 2 | 3 |
7 | 8 | 0.20 | 175 | 15.07 | 299 | 789 | 4.64 / 432.97 | 2 | 11 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 35 | 15.05 | 433 | 228 | 0.23 / 424.01 | 2 | 2 |
2 | 12 | 1165.72 | 5 | 15.23 | 1862 | 142 | 0.37 / 424.15 | 2 | 2 |
3 | 7 | 2002.08 | 47 | 14.81 | 2740 | 1907 | 2.28 / 426.06 | 2 | 2 |
4 | 13 | 1261.16 | 31 | 14.86 | 1920 | 884 | 3.16 / 426.94 | 2 | 3 |
5 | 13 | 310.08 | 31 | 15.04 | 765 | 357 | 3.52 / 427.30 | 2 | 3 |
6 | 13 | 80.68 | 31 | 15.09 | 429 | 201 | 3.72 / 427.50 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.08 | 312 | 823 | 4.54 / 428.32 | 2 | 10 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 35 | 15.04 | 438 | 231 | 0.23 / 419.63 | 2 | 2 |
2 | 12 | 1157.60 | 5 | 15.24 | 1862 | 142 | 0.37 / 419.77 | 2 | 2 |
3 | 7 | 2002.92 | 47 | 14.80 | 2758 | 1918 | 2.29 / 421.69 | 2 | 2 |
4 | 13 | 1104.60 | 31 | 14.88 | 1743 | 804 | 3.09 / 422.50 | 2 | 3 |
5 | 13 | 224.00 | 31 | 15.07 | 630 | 294 | 3.39 / 422.79 | 2 | 3 |
6 | 13 | 63.20 | 31 | 15.10 | 408 | 191 | 3.58 / 422.98 | 2 | 3 |
7 | 8 | 0.16 | 175 | 15.08 | 303 | 800 | 4.38 / 423.78 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.52 | 35 | 15.06 | 414 | 218 | 0.22 / 415.15 | 2 | 2 |
2 | 12 | 1171.64 | 5 | 15.24 | 1853 | 141 | 0.36 / 415.29 | 2 | 2 |
3 | 7 | 2003.00 | 47 | 14.80 | 2739 | 1905 | 2.26 / 417.20 | 2 | 2 |
4 | 13 | 1224.64 | 31 | 14.87 | 1866 | 860 | 3.12 / 418.06 | 2 | 3 |
5 | 13 | 283.36 | 31 | 15.05 | 722 | 337 | 3.46 / 418.40 | 2 | 3 |
6 | 13 | 83.48 | 31 | 15.10 | 430 | 201 | 3.66 / 418.60 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.08 | 305 | 805 | 4.47 / 419.40 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 35 | 15.04 | 440 | 232 | 0.23 / 410.79 | 2 | 2 |
2 | 12 | 1168.36 | 5 | 15.25 | 1848 | 141 | 0.37 / 410.93 | 2 | 2 |
3 | 7 | 2002.28 | 48 | 14.80 | 2728 | 1938 | 2.31 / 412.87 | 2 | 2 |
4 | 13 | 1111.64 | 31 | 14.89 | 1737 | 802 | 3.11 / 413.67 | 2 | 3 |
5 | 13 | 241.72 | 31 | 15.07 | 653 | 305 | 3.42 / 413.98 | 2 | 3 |
6 | 13 | 81.84 | 31 | 15.11 | 408 | 191 | 3.61 / 414.17 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.09 | 290 | 766 | 4.37 / 414.93 | 2 | 8 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 35 | 15.05 | 418 | 220 | 0.22 / 406.24 | 2 | 2 |
2 | 12 | 1169.16 | 5 | 15.24 | 1880 | 143 | 0.36 / 406.38 | 2 | 2 |
3 | 7 | 2003.52 | 47 | 14.80 | 2762 | 1921 | 2.28 / 408.30 | 2 | 2 |
4 | 13 | 1268.28 | 31 | 14.85 | 1925 | 886 | 3.17 / 409.19 | 2 | 3 |
5 | 13 | 307.88 | 31 | 15.04 | 767 | 358 | 3.53 / 409.55 | 2 | 3 |
6 | 13 | 82.24 | 31 | 15.10 | 434 | 203 | 3.73 / 409.75 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.08 | 307 | 810 | 4.54 / 410.56 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 36 | 15.06 | 422 | 229 | 0.23 / 401.70 | 2 | 2 |
2 | 12 | 1165.00 | 5 | 15.25 | 1864 | 142 | 0.37 / 401.84 | 2 | 2 |
3 | 7 | 2003.80 | 47 | 14.80 | 2757 | 1918 | 2.29 / 403.76 | 2 | 2 |
4 | 13 | 1265.76 | 31 | 14.85 | 1942 | 894 | 3.18 / 404.65 | 2 | 3 |
5 | 13 | 316.56 | 31 | 15.04 | 771 | 359 | 3.54 / 405.01 | 2 | 3 |
6 | 13 | 89.32 | 31 | 15.10 | 445 | 208 | 3.75 / 405.22 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.08 | 302 | 797 | 4.55 / 406.02 | 2 | 8 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 35 | 15.06 | 428 | 226 | 0.23 / 397.25 | 2 | 2 |
2 | 12 | 1169.04 | 5 | 15.25 | 1841 | 140 | 0.37 / 397.39 | 2 | 2 |
3 | 7 | 2002.40 | 47 | 14.81 | 2730 | 1900 | 2.27 / 399.29 | 2 | 2 |
4 | 13 | 1235.52 | 31 | 14.87 | 1871 | 862 | 3.13 / 400.15 | 2 | 3 |
5 | 13 | 298.00 | 31 | 15.05 | 735 | 343 | 3.47 / 400.50 | 2 | 3 |
6 | 13 | 76.76 | 31 | 15.11 | 410 | 192 | 3.66 / 400.69 | 2 | 3 |
7 | 8 | 0.16 | 175 | 15.09 | 296 | 782 | 4.45 / 401.47 | 2 | 11 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 35 | 15.05 | 430 | 227 | 0.23 / 392.86 | 2 | 2 |
2 | 12 | 1163.20 | 5 | 15.25 | 1855 | 141 | 0.37 / 393.00 | 2 | 2 |
3 | 7 | 2002.92 | 47 | 14.80 | 2759 | 1919 | 2.29 / 394.92 | 2 | 2 |
4 | 13 | 1104.08 | 31 | 14.90 | 1745 | 806 | 3.09 / 395.73 | 2 | 3 |
5 | 13 | 246.00 | 31 | 15.07 | 677 | 316 | 3.41 / 396.05 | 2 | 3 |
6 | 13 | 83.04 | 31 | 15.11 | 431 | 202 | 3.61 / 396.25 | 2 | 3 |
7 | 8 | 0.04 | 175 | 15.09 | 294 | 776 | 4.39 / 397.02 | 2 | 10 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 35 | 15.05 | 427 | 225 | 0.22 / 388.38 | 2 | 2 |
2 | 12 | 1160.60 | 5 | 15.25 | 1859 | 142 | 0.37 / 388.52 | 2 | 2 |
3 | 7 | 2003.08 | 47 | 14.80 | 2765 | 1923 | 2.29 / 390.45 | 2 | 2 |
4 | 13 | 1100.40 | 31 | 14.90 | 1733 | 800 | 3.09 / 391.25 | 2 | 3 |
5 | 13 | 344.52 | 31 | 15.04 | 801 | 373 | 3.46 / 391.62 | 2 | 3 |
6 | 13 | 91.04 | 31 | 15.10 | 450 | 211 | 3.67 / 391.83 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.08 | 305 | 805 | 4.48 / 392.64 | 2 | 7 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 35 | 15.05 | 435 | 229 | 0.23 / 383.86 | 2 | 2 |
2 | 12 | 1158.36 | 5 | 15.26 | 1859 | 142 | 0.37 / 384.00 | 2 | 2 |
3 | 7 | 2005.16 | 47 | 14.81 | 2762 | 1923 | 2.29 / 385.92 | 2 | 2 |
4 | 13 | 1125.96 | 31 | 14.89 | 1766 | 815 | 3.11 / 386.74 | 2 | 3 |
5 | 13 | 378.48 | 31 | 15.03 | 843 | 393 | 3.50 / 387.13 | 2 | 3 |
6 | 13 | 90.56 | 31 | 15.10 | 447 | 209 | 3.71 / 387.34 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.08 | 309 | 815 | 4.53 / 388.16 | 2 | 10 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 35 | 15.06 | 438 | 231 | 0.23 / 379.32 | 2 | 2 |
2 | 12 | 1173.48 | 5 | 15.25 | 1873 | 143 | 0.37 / 379.46 | 2 | 2 |
3 | 7 | 2001.24 | 47 | 14.81 | 2760 | 1921 | 2.29 / 381.38 | 2 | 2 |
4 | 13 | 1239.88 | 31 | 14.87 | 1898 | 875 | 3.17 / 382.26 | 2 | 3 |
5 | 13 | 302.40 | 31 | 15.05 | 752 | 351 | 3.52 / 382.61 | 2 | 3 |
6 | 13 | 87.64 | 31 | 15.10 | 446 | 209 | 3.73 / 382.82 | 2 | 3 |
7 | 8 | 0.16 | 175 | 15.09 | 308 | 813 | 4.54 / 383.63 | 2 | 9 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 35 | 15.07 | 429 | 226 | 0.23 / 374.78 | 2 | 2 |
2 | 12 | 1163.16 | 5 | 15.26 | 1828 | 139 | 0.37 / 374.92 | 2 | 2 |
3 | 7 | 2002.20 | 47 | 14.82 | 2745 | 1912 | 2.28 / 376.83 | 2 | 2 |
4 | 13 | 1246.04 | 31 | 14.88 | 1911 | 882 | 3.16 / 377.71 | 2 | 3 |
5 | 13 | 305.32 | 31 | 15.06 | 757 | 353 | 3.51 / 378.07 | 2 | 3 |
6 | 13 | 77.12 | 31 | 15.11 | 430 | 201 | 3.71 / 378.27 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.09 | 311 | 821 | 4.54 / 379.09 | 2 | 8 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 35 | 15.06 | 434 | 229 | 0.23 / 370.39 | 2 | 2 |
2 | 12 | 1165.92 | 5 | 15.26 | 1841 | 140 | 0.37 / 370.53 | 2 | 2 |
3 | 7 | 2001.72 | 47 | 14.81 | 2759 | 1920 | 2.29 / 372.45 | 2 | 2 |
4 | 13 | 1102.96 | 31 | 14.90 | 1745 | 806 | 3.10 / 373.26 | 2 | 3 |
5 | 13 | 235.32 | 31 | 15.08 | 651 | 304 | 3.40 / 373.56 | 2 | 3 |
6 | 13 | 72.32 | 31 | 15.12 | 408 | 191 | 3.59 / 373.76 | 2 | 3 |
7 | 8 | 0.00 | 175 | 15.10 | 302 | 798 | 4.39 / 374.55 | 2 | 7 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 35 | 15.06 | 431 | 227 | 0.23 / 365.92 | 2 | 2 |
2 | 12 | 1185.56 | 5 | 15.25 | 1842 | 140 | 0.37 / 366.06 | 2 | 2 |
3 | 7 | 2001.52 | 47 | 14.82 | 2732 | 1903 | 2.27 / 367.97 | 2 | 2 |
4 | 13 | 1115.64 | 31 | 14.91 | 1736 | 802 | 3.07 / 368.77 | 2 | 3 |
5 | 13 | 359.16 | 31 | 15.04 | 820 | 382 | 3.46 / 369.15 | 2 | 3 |
6 | 13 | 87.48 | 31 | 15.11 | 442 | 207 | 3.66 / 369.36 | 2 | 3 |
7 | 8 | 0.04 | 175 | 15.09 | 305 | 805 | 4.47 / 370.16 | 2 | 10 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 35 | 15.06 | 430 | 227 | 0.23 / 361.43 | 2 | 2 |
2 | 12 | 1161.08 | 5 | 15.26 | 1863 | 142 | 0.37 / 361.57 | 2 | 2 |
3 | 7 | 2004.92 | 47 | 14.82 | 2763 | 1925 | 2.29 / 363.49 | 2 | 2 |
4 | 13 | 1105.28 | 31 | 14.91 | 1743 | 806 | 3.10 / 364.30 | 2 | 3 |
5 | 13 | 352.20 | 31 | 15.05 | 817 | 381 | 3.48 / 364.68 | 2 | 3 |
6 | 13 | 86.76 | 31 | 15.11 | 442 | 207 | 3.69 / 364.89 | 2 | 3 |
7 | 8 | 0.12 | 175 | 15.10 | 306 | 809 | 4.50 / 365.70 | 2 | 11 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 35 | 15.07 | 419 | 221 | 0.22 / 356.96 | 2 | 2 |
2 | 12 | 1158.44 | 5 | 15.26 | 1847 | 141 | 0.36 / 357.10 | 2 | 2 |
3 | 7 | 2001.68 | 47 | 14.82 | 2750 | 1915 | 2.28 / 359.02 | 2 | 2 |
4 | 13 | 1106.92 | 31 | 14.91 | 1731 | 800 | 3.08 / 359.82 | 2 | 3 |
5 | 13 | 357.04 | 31 | 15.05 | 824 | 384 | 3.46 / 360.20 | 2 | 3 |
6 | 13 | 82.72 | 31 | 15.11 | 437 | 205 | 3.67 / 360.40 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.10 | 301 | 795 | 4.46 / 361.20 | 2 | 12 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 35 | 15.08 | 437 | 231 | 0.23 / 352.54 | 2 | 2 |
2 | 12 | 1165.12 | 5 | 15.26 | 1837 | 140 | 0.37 / 352.68 | 2 | 2 |
3 | 7 | 2001.00 | 47 | 14.82 | 2739 | 1908 | 2.28 / 354.59 | 2 | 2 |
4 | 13 | 1090.16 | 31 | 14.92 | 1704 | 788 | 3.07 / 355.38 | 2 | 3 |
5 | 13 | 321.52 | 31 | 15.06 | 781 | 365 | 3.43 / 355.74 | 2 | 3 |
6 | 13 | 70.76 | 31 | 15.12 | 421 | 197 | 3.63 / 355.94 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.10 | 302 | 798 | 4.43 / 356.74 | 2 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 35 | 15.09 | 416 | 220 | 0.22 / 348.02 | 2 | 2 |
2 | 12 | 1175.16 | 5 | 15.26 | 1852 | 141 | 0.36 / 348.16 | 2 | 2 |
3 | 7 | 2002.32 | 47 | 14.83 | 2740 | 1910 | 2.27 / 350.07 | 2 | 2 |
4 | 13 | 1254.40 | 31 | 14.89 | 1916 | 884 | 3.16 / 350.95 | 2 | 3 |
5 | 13 | 320.92 | 31 | 15.06 | 785 | 366 | 3.52 / 351.32 | 2 | 3 |
6 | 13 | 88.56 | 31 | 15.13 | 431 | 202 | 3.72 / 351.52 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.11 | 298 | 788 | 4.51 / 352.31 | 2 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 35 | 15.09 | 437 | 231 | 0.23 / 343.55 | 2 | 2 |
2 | 12 | 1184.24 | 5 | 15.27 | 1875 | 143 | 0.37 / 343.70 | 2 | 2 |
3 | 7 | 2000.56 | 47 | 14.83 | 2742 | 1911 | 2.29 / 345.61 | 2 | 2 |
4 | 13 | 1237.72 | 31 | 14.89 | 1892 | 873 | 3.16 / 346.48 | 2 | 3 |
5 | 13 | 287.24 | 31 | 15.08 | 739 | 345 | 3.50 / 346.83 | 2 | 3 |
6 | 13 | 86.20 | 31 | 15.13 | 422 | 198 | 3.70 / 347.02 | 2 | 3 |
7 | 8 | 0.04 | 175 | 15.12 | 293 | 775 | 4.48 / 347.80 | 2 | 10 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 35 | 15.10 | 423 | 224 | 0.22 / 339.14 | 2 | 2 |
2 | 12 | 1161.00 | 5 | 15.27 | 1876 | 143 | 0.37 / 339.28 | 2 | 2 |
3 | 7 | 2004.16 | 47 | 14.82 | 2759 | 1922 | 2.29 / 341.20 | 2 | 2 |
4 | 13 | 1113.04 | 31 | 14.92 | 1743 | 806 | 3.09 / 342.01 | 2 | 3 |
5 | 13 | 237.60 | 31 | 15.10 | 660 | 309 | 3.40 / 342.32 | 2 | 3 |
6 | 13 | 77.00 | 31 | 15.14 | 428 | 201 | 3.60 / 342.52 | 2 | 3 |
7 | 8 | 0.08 | 175 | 15.12 | 303 | 802 | 4.41 / 343.32 | 2 | 8 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.44 | 34 | 15.09 | 434 | 223 | 0.22 / 334.71 | 2 | 2 |
2 | 3 | 1022.00 | 1 | 15.25 | 1710 | 26 | 0.25 / 334.73 | 2 | 2 |
3 | 12 | 1154.68 | 5 | 15.28 | 1862 | 142 | 0.39 / 334.88 | 2 | 2 |
4 | 7 | 2000.84 | 48 | 14.83 | 2763 | 1967 | 2.36 / 336.84 | 2 | 2 |
5 | 13 | 1091.20 | 31 | 14.93 | 1715 | 794 | 3.15 / 337.64 | 2 | 3 |
6 | 13 | 213.32 | 31 | 15.11 | 638 | 299 | 3.45 / 337.94 | 2 | 3 |
7 | 13 | 78.76 | 31 | 15.14 | 420 | 197 | 3.65 / 338.13 | 2 | 3 |
8 | 8 | 0.08 | 175 | 15.13 | 296 | 784 | 4.43 / 338.92 | 2 | 9 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 38 | 15.09 | 434 | 249 | 0.25 / 330.36 | 2 | 2 |
2 | 3 | 910.00 | -2 | 15.53 | 0 | 0 | 0.00 / 330.36 | 2 | 2 |
3 | 12 | 1132.12 | 5 | 15.29 | 1806 | 138 | 0.39 / 330.50 | 2 | 2 |
4 | 7 | 2002.32 | 47 | 14.83 | 2748 | 1915 | 2.30 / 332.41 | 2 | 2 |
5 | 13 | 1100.56 | 31 | 14.92 | 1736 | 803 | 3.11 / 333.22 | 2 | 3 |
6 | 13 | 199.88 | 31 | 15.12 | 604 | 283 | 3.39 / 333.50 | 2 | 3 |
7 | 13 | 63.96 | 31 | 15.15 | 403 | 189 | 3.58 / 333.69 | 2 | 3 |
8 | 8 | 0.08 | 175 | 15.13 | 301 | 797 | 4.37 / 334.49 | 2 | 11 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 42 | 15.10 | 412 | 261 | 0.26 / 325.64 | 2 | 2 |
2 | 3 | 915.96 | -2 | 15.54 | 0 | 0 | 0.00 / 325.64 | 2 | 2 |
3 | 3 | 971.48 | -1 | 15.56 | 0 | 0 | 0.00 / 325.64 | 2 | 2 |
4 | 12 | 1151.72 | 5 | 15.30 | 1665 | 127 | 0.39 / 325.76 | 2 | 2 |
5 | 7 | 2002.36 | 47 | 14.92 | 2460 | 1725 | 2.11 / 327.49 | 2 | 2 |
6 | 13 | 1496.52 | 31 | 14.96 | 1893 | 878 | 2.99 / 328.37 | 2 | 2 |
7 | 13 | 764.60 | 31 | 15.00 | 1169 | 544 | 3.54 / 328.91 | 2 | 2 |
8 | 13 | 136.32 | 31 | 15.14 | 484 | 227 | 3.76 / 329.14 | 2 | 2 |
9 | 13 | 44.48 | 31 | 15.15 | 373 | 175 | 3.94 / 329.31 | 2 | 2 |
10 | 8 | 0.12 | 175 | 15.12 | 302 | 799 | 4.74 / 330.11 | 2 | 10 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 36 | 15.12 | 388 | 211 | 0.21 / 320.80 | 2 | 2 |
2 | 10 | 1001.32 | 5 | 15.16 | 1422 | 108 | 0.32 / 320.90 | 2 | 2 |
3 | 10 | 1035.36 | 3 | 15.17 | 1464 | 67 | 0.39 / 320.97 | 2 | 2 |
4 | 3 | 1014.72 | 1 | 15.27 | 1466 | 22 | 0.41 / 320.99 | 2 | 2 |
5 | 12 | 1299.16 | 5 | 15.28 | 1747 | 133 | 0.54 / 321.13 | 2 | 2 |
6 | 7 | 2004.16 | 47 | 14.98 | 2264 | 1594 | 2.14 / 322.72 | 2 | 2 |
7 | 13 | 1493.52 | 31 | 14.98 | 1798 | 835 | 2.97 / 323.55 | 2 | 2 |
8 | 13 | 806.52 | 31 | 15.02 | 1140 | 531 | 3.50 / 324.09 | 2 | 2 |
9 | 13 | 261.80 | 31 | 15.10 | 632 | 296 | 3.80 / 324.38 | 2 | 2 |
10 | 13 | 77.64 | 31 | 15.15 | 405 | 190 | 3.99 / 324.57 | 2 | 2 |
11 | 8 | 0.08 | 175 | 15.13 | 303 | 802 | 4.79 / 325.37 | 2 | 6 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 38 | 15.12 | 415 | 238 | 0.24 / 316.24 | 2 | 2 |
2 | 3 | 935.28 | -1 | 15.54 | 0 | 0 | 0.00 / 316.24 | 2 | 2 |
3 | 3 | 971.60 | -1 | 15.57 | 0 | 0 | 0.00 / 316.24 | 2 | 2 |
4 | 12 | 1179.20 | 5 | 15.31 | 1682 | 129 | 0.37 / 316.37 | 2 | 2 |
5 | 7 | 2004.48 | 47 | 14.92 | 2454 | 1721 | 2.09 / 318.09 | 2 | 2 |
6 | 13 | 1325.72 | 31 | 14.95 | 1761 | 816 | 2.90 / 318.91 | 2 | 2 |
7 | 13 | 632.52 | 31 | 15.03 | 1039 | 484 | 3.39 / 319.39 | 2 | 2 |
8 | 13 | 138.32 | 31 | 15.14 | 497 | 233 | 3.62 / 319.63 | 2 | 3 |
9 | 13 | 46.16 | 31 | 15.16 | 367 | 172 | 3.79 / 319.80 | 2 | 2 |
10 | 8 | 0.00 | 175 | 15.13 | 296 | 784 | 4.58 / 320.58 | 2 | 7 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 38 | 15.12 | 410 | 236 | 0.24 / 311.70 | 2 | 2 |
2 | 12 | 1156.60 | 5 | 15.32 | 1636 | 125 | 0.36 / 311.83 | 2 | 2 |
3 | 7 | 2001.52 | 47 | 14.94 | 2410 | 1692 | 2.05 / 313.52 | 2 | 2 |
4 | 13 | 1331.04 | 31 | 14.95 | 1779 | 824 | 2.88 / 314.34 | 2 | 2 |
5 | 13 | 663.48 | 31 | 15.03 | 1064 | 496 | 3.37 / 314.84 | 2 | 2 |
6 | 13 | 154.96 | 31 | 15.15 | 500 | 235 | 3.61 / 315.07 | 2 | 2 |
7 | 13 | 56.40 | 31 | 15.17 | 368 | 173 | 3.78 / 315.25 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.14 | 287 | 760 | 4.54 / 316.01 | 2 | 10 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 38 | 15.13 | 402 | 231 | 0.23 / 307.03 | 2 | 2 |
2 | 12 | 1173.68 | 5 | 15.31 | 1659 | 127 | 0.36 / 307.15 | 2 | 2 |
3 | 7 | 2004.00 | 47 | 14.95 | 2398 | 1685 | 2.04 / 308.84 | 2 | 2 |
4 | 13 | 1467.96 | 31 | 14.98 | 1837 | 853 | 2.90 / 309.69 | 2 | 2 |
5 | 13 | 753.28 | 31 | 15.03 | 1134 | 528 | 3.42 / 310.22 | 2 | 2 |
6 | 13 | 194.24 | 31 | 15.14 | 561 | 263 | 3.69 / 310.48 | 2 | 2 |
7 | 13 | 61.40 | 31 | 15.17 | 383 | 180 | 3.87 / 310.66 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.14 | 303 | 803 | 4.67 / 311.46 | 2 | 6 |
Average= | 4.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 38 | 15.13 | 420 | 241 | 0.24 / 302.33 | 2 | 2 |
2 | 3 | 1015.44 | 1 | 15.28 | 1527 | 23 | 0.26 / 302.35 | 2 | 2 |
3 | 12 | 1173.28 | 5 | 15.31 | 1677 | 128 | 0.39 / 302.48 | 2 | 2 |
4 | 7 | 2003.12 | 47 | 14.94 | 2405 | 1689 | 2.08 / 304.17 | 2 | 2 |
5 | 13 | 1483.80 | 31 | 14.97 | 1851 | 859 | 2.94 / 305.03 | 2 | 2 |
6 | 13 | 747.92 | 31 | 15.04 | 1138 | 531 | 3.47 / 305.56 | 2 | 2 |
7 | 13 | 200.20 | 31 | 15.14 | 574 | 269 | 3.74 / 305.83 | 2 | 2 |
8 | 13 | 61.24 | 31 | 15.17 | 388 | 182 | 3.92 / 306.01 | 2 | 2 |
9 | 8 | 0.20 | 175 | 15.15 | 296 | 785 | 4.71 / 306.79 | 2 | 7 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 38 | 15.14 | 409 | 235 | 0.24 / 297.58 | 2 | 2 |
2 | 12 | 1145.72 | 5 | 15.38 | 1548 | 119 | 0.35 / 297.70 | 2 | 2 |
3 | 7 | 2005.04 | 47 | 14.96 | 2396 | 1685 | 2.04 / 299.39 | 2 | 2 |
4 | 13 | 1486.44 | 31 | 14.96 | 1897 | 880 | 2.92 / 300.27 | 2 | 2 |
5 | 13 | 907.12 | 31 | 14.99 | 1309 | 608 | 3.53 / 300.88 | 2 | 2 |
6 | 13 | 172.44 | 31 | 15.15 | 545 | 256 | 3.78 / 301.13 | 2 | 2 |
7 | 13 | 59.20 | 31 | 15.18 | 374 | 176 | 3.96 / 301.31 | 2 | 2 |
8 | 8 | 0.20 | 175 | 15.16 | 293 | 777 | 4.74 / 302.09 | 2 | 5 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 39 | 15.14 | 414 | 244 | 0.24 / 293.04 | 2 | 2 |
2 | 12 | 1175.40 | 5 | 15.32 | 1612 | 123 | 0.37 / 293.16 | 2 | 2 |
3 | 7 | 2003.44 | 47 | 14.96 | 2395 | 1684 | 2.05 / 294.84 | 2 | 2 |
4 | 13 | 1344.00 | 31 | 14.97 | 1753 | 814 | 2.87 / 295.66 | 2 | 2 |
5 | 13 | 659.72 | 31 | 15.06 | 1047 | 489 | 3.35 / 296.15 | 2 | 2 |
6 | 13 | 163.56 | 31 | 15.17 | 520 | 245 | 3.60 / 296.39 | 2 | 2 |
7 | 13 | 61.88 | 31 | 15.19 | 379 | 178 | 3.78 / 296.57 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.17 | 294 | 780 | 4.56 / 297.35 | 2 | 6 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.80 | 38 | 15.14 | 426 | 245 | 0.25 / 288.25 | 2 | 2 |
2 | 3 | 1019.00 | 1 | 15.29 | 1472 | 23 | 0.27 / 288.27 | 2 | 2 |
3 | 12 | 1155.56 | 5 | 15.34 | 1510 | 116 | 0.38 / 288.39 | 2 | 2 |
4 | 7 | 2004.88 | 47 | 14.95 | 2416 | 1698 | 2.08 / 290.09 | 2 | 2 |
5 | 13 | 1493.16 | 31 | 14.96 | 1903 | 883 | 2.96 / 290.97 | 2 | 2 |
6 | 13 | 768.72 | 31 | 15.05 | 1162 | 542 | 3.51 / 291.51 | 2 | 2 |
7 | 13 | 218.16 | 31 | 15.15 | 593 | 279 | 3.78 / 291.79 | 2 | 2 |
8 | 13 | 70.68 | 31 | 15.19 | 407 | 192 | 3.98 / 291.98 | 2 | 2 |
9 | 8 | 0.04 | 175 | 15.16 | 306 | 812 | 4.79 / 292.79 | 2 | 5 |
Average= | 4.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 38 | 15.16 | 418 | 241 | 0.24 / 283.58 | 2 | 2 |
2 | 12 | 1158.36 | 5 | 15.31 | 1678 | 128 | 0.37 / 283.71 | 2 | 2 |
3 | 7 | 2005.16 | 47 | 14.96 | 2389 | 1680 | 2.05 / 285.39 | 2 | 2 |
4 | 13 | 1345.60 | 31 | 14.98 | 1754 | 815 | 2.86 / 286.20 | 2 | 2 |
5 | 13 | 812.44 | 31 | 15.03 | 1201 | 560 | 3.42 / 286.76 | 2 | 2 |
6 | 13 | 158.28 | 31 | 15.18 | 506 | 238 | 3.66 / 287.00 | 2 | 2 |
7 | 13 | 84.28 | 31 | 15.19 | 419 | 197 | 3.86 / 287.20 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.17 | 303 | 804 | 4.66 / 288.00 | 2 | 5 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 39 | 15.16 | 410 | 242 | 0.24 / 278.96 | 2 | 2 |
2 | 12 | 1165.08 | 5 | 15.32 | 1688 | 129 | 0.37 / 279.09 | 2 | 2 |
3 | 7 | 2004.56 | 48 | 14.95 | 2426 | 1741 | 2.11 / 280.83 | 2 | 2 |
4 | 13 | 1451.08 | 31 | 14.99 | 1845 | 857 | 2.97 / 281.69 | 2 | 2 |
5 | 13 | 586.44 | 31 | 15.09 | 979 | 458 | 3.43 / 282.15 | 2 | 2 |
6 | 13 | 149.32 | 31 | 15.19 | 500 | 235 | 3.66 / 282.38 | 2 | 2 |
7 | 13 | 54.72 | 31 | 15.21 | 375 | 177 | 3.84 / 282.56 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.19 | 294 | 782 | 4.62 / 283.34 | 2 | 8 |
Average= | 4.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 39 | 15.16 | 421 | 249 | 0.25 / 274.29 | 2 | 2 |
2 | 12 | 1174.48 | 5 | 15.40 | 1527 | 118 | 0.37 / 274.41 | 2 | 2 |
3 | 7 | 2002.84 | 47 | 14.95 | 2411 | 1694 | 2.06 / 276.10 | 2 | 2 |
4 | 13 | 1464.76 | 31 | 14.98 | 1838 | 854 | 2.91 / 276.96 | 2 | 2 |
5 | 13 | 747.52 | 31 | 15.05 | 1153 | 538 | 3.45 / 277.50 | 2 | 2 |
6 | 13 | 202.84 | 31 | 15.18 | 560 | 264 | 3.72 / 277.76 | 2 | 2 |
7 | 13 | 60.80 | 31 | 15.21 | 384 | 181 | 3.90 / 277.94 | 2 | 2 |
8 | 8 | 0.04 | 175 | 15.19 | 293 | 779 | 4.68 / 278.72 | 2 | 8 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 39 | 15.18 | 401 | 237 | 0.24 / 269.63 | 2 | 2 |
2 | 12 | 1166.56 | 5 | 15.33 | 1664 | 128 | 0.36 / 269.76 | 2 | 2 |
3 | 7 | 2006.12 | 47 | 14.96 | 2407 | 1692 | 2.06 / 271.45 | 2 | 2 |
4 | 13 | 1325.16 | 31 | 15.01 | 1706 | 794 | 2.85 / 272.24 | 2 | 2 |
5 | 13 | 788.32 | 31 | 15.06 | 1173 | 548 | 3.40 / 272.79 | 2 | 2 |
6 | 13 | 221.36 | 31 | 15.17 | 596 | 280 | 3.68 / 273.07 | 2 | 3 |
7 | 13 | 58.84 | 31 | 15.21 | 385 | 182 | 3.86 / 273.25 | 2 | 2 |
8 | 8 | 0.04 | 175 | 15.19 | 298 | 792 | 4.65 / 274.04 | 2 | 6 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.80 | 39 | 15.17 | 405 | 240 | 0.24 / 265.07 | 2 | 2 |
2 | 12 | 1178.76 | 5 | 15.33 | 1659 | 127 | 0.37 / 265.20 | 2 | 2 |
3 | 7 | 2008.76 | 47 | 14.98 | 2389 | 1682 | 2.05 / 266.88 | 2 | 2 |
4 | 13 | 1351.20 | 31 | 15.00 | 1727 | 803 | 2.85 / 267.69 | 2 | 2 |
5 | 13 | 673.28 | 31 | 15.08 | 1077 | 503 | 3.36 / 268.19 | 2 | 2 |
6 | 13 | 170.40 | 31 | 15.20 | 524 | 247 | 3.60 / 268.44 | 2 | 2 |
7 | 13 | 57.88 | 31 | 15.22 | 376 | 177 | 3.78 / 268.61 | 2 | 3 |
8 | 8 | 0.16 | 175 | 15.20 | 292 | 777 | 4.56 / 269.39 | 2 | 6 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 39 | 15.18 | 418 | 247 | 0.25 / 260.33 | 2 | 2 |
2 | 12 | 1152.92 | 5 | 15.34 | 1660 | 127 | 0.37 / 260.46 | 2 | 2 |
3 | 7 | 2003.44 | 47 | 14.97 | 2403 | 1691 | 2.07 / 262.15 | 2 | 2 |
4 | 13 | 1488.12 | 31 | 14.98 | 1878 | 872 | 2.94 / 263.02 | 2 | 2 |
5 | 13 | 791.80 | 31 | 15.06 | 1188 | 555 | 3.49 / 263.57 | 2 | 2 |
6 | 13 | 238.60 | 31 | 15.17 | 621 | 292 | 3.78 / 263.87 | 2 | 2 |
7 | 13 | 61.44 | 31 | 15.22 | 385 | 182 | 3.97 / 264.05 | 2 | 3 |
8 | 8 | 0.12 | 175 | 15.20 | 296 | 787 | 4.75 / 264.84 | 2 | 6 |
Average= | 4.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 39 | 15.18 | 411 | 243 | 0.24 / 255.70 | 2 | 2 |
2 | 12 | 1167.04 | 5 | 15.37 | 1487 | 114 | 0.36 / 255.81 | 2 | 2 |
3 | 7 | 2004.20 | 47 | 14.98 | 2388 | 1681 | 2.04 / 257.49 | 2 | 2 |
4 | 13 | 1477.72 | 31 | 15.00 | 1847 | 859 | 2.90 / 258.35 | 2 | 2 |
5 | 13 | 736.84 | 31 | 15.11 | 1104 | 517 | 3.41 / 258.87 | 2 | 2 |
6 | 13 | 190.60 | 31 | 15.20 | 545 | 257 | 3.67 / 259.12 | 2 | 2 |
7 | 13 | 55.68 | 31 | 15.23 | 378 | 178 | 3.85 / 259.30 | 2 | 3 |
8 | 8 | 0.12 | 175 | 15.21 | 293 | 780 | 4.63 / 260.08 | 2 | 4 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 39 | 15.19 | 404 | 239 | 0.24 / 251.02 | 2 | 2 |
2 | 12 | 1171.40 | 5 | 15.33 | 1674 | 128 | 0.37 / 251.15 | 2 | 2 |
3 | 7 | 2006.68 | 47 | 14.97 | 2400 | 1689 | 2.06 / 252.84 | 2 | 2 |
4 | 13 | 1367.96 | 31 | 15.00 | 1773 | 824 | 2.88 / 253.67 | 2 | 2 |
5 | 13 | 835.48 | 31 | 15.06 | 1229 | 574 | 3.45 / 254.24 | 2 | 2 |
6 | 13 | 141.00 | 31 | 15.22 | 492 | 232 | 3.69 / 254.47 | 2 | 3 |
7 | 13 | 47.12 | 31 | 15.23 | 379 | 179 | 3.87 / 254.65 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.21 | 301 | 801 | 4.67 / 255.45 | 2 | 6 |
Average= | 4.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 39 | 15.19 | 424 | 251 | 0.25 / 246.39 | 2 | 2 |
2 | 12 | 1173.20 | 5 | 15.43 | 1508 | 116 | 0.37 / 246.51 | 2 | 2 |
3 | 7 | 2004.88 | 48 | 14.98 | 2403 | 1728 | 2.10 / 248.23 | 2 | 2 |
4 | 13 | 1489.84 | 31 | 14.99 | 1882 | 875 | 2.97 / 249.11 | 2 | 2 |
5 | 13 | 611.44 | 31 | 15.13 | 1002 | 470 | 3.44 / 249.58 | 2 | 3 |
6 | 13 | 147.44 | 31 | 15.23 | 501 | 237 | 3.68 / 249.81 | 2 | 2 |
7 | 13 | 44.24 | 31 | 15.24 | 369 | 174 | 3.85 / 249.99 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.22 | 299 | 796 | 4.65 / 250.78 | 2 | 7 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.80 | 39 | 15.21 | 394 | 234 | 0.23 / 241.73 | 2 | 2 |
2 | 12 | 1151.00 | 5 | 15.44 | 1504 | 116 | 0.35 / 241.84 | 2 | 2 |
3 | 7 | 2006.04 | 48 | 14.97 | 2389 | 1717 | 2.07 / 243.56 | 2 | 2 |
4 | 13 | 1342.64 | 31 | 15.02 | 1732 | 806 | 2.87 / 244.37 | 2 | 2 |
5 | 13 | 806.08 | 31 | 15.08 | 1188 | 555 | 3.43 / 244.92 | 2 | 3 |
6 | 13 | 141.36 | 31 | 15.23 | 489 | 231 | 3.66 / 245.15 | 2 | 3 |
7 | 13 | 37.88 | 31 | 15.25 | 364 | 172 | 3.83 / 245.32 | 2 | 3 |
8 | 8 | 0.04 | 175 | 15.21 | 306 | 814 | 4.65 / 246.14 | 2 | 7 |
Average= | 4.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 39 | 15.21 | 406 | 241 | 0.24 / 237.07 | 2 | 2 |
2 | 12 | 1181.64 | 5 | 15.34 | 1641 | 126 | 0.37 / 237.19 | 2 | 2 |
3 | 7 | 2001.92 | 47 | 14.98 | 2387 | 1681 | 2.05 / 238.87 | 2 | 2 |
4 | 13 | 1479.40 | 31 | 14.98 | 1887 | 876 | 2.92 / 239.75 | 2 | 2 |
5 | 13 | 750.56 | 31 | 15.12 | 1113 | 522 | 3.45 / 240.27 | 2 | 2 |
6 | 13 | 136.08 | 31 | 15.24 | 476 | 225 | 3.67 / 240.49 | 2 | 2 |
7 | 13 | 50.12 | 31 | 15.25 | 367 | 173 | 3.84 / 240.67 | 2 | 2 |
8 | 8 | 0.00 | 175 | 15.23 | 285 | 760 | 4.60 / 241.43 | 2 | 7 |
9 | 14 | 0.00 | 15 | 15.21 | 281 | 64 | 4.67 / 241.49 | 2 | 5 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 38 | 15.21 | 406 | 235 | 0.23 / 232.47 | 2 | 2 |
2 | 3 | 1014.32 | 1 | 15.42 | 1366 | 21 | 0.26 / 232.49 | 2 | 2 |
3 | 12 | 1175.08 | 5 | 15.34 | 1645 | 126 | 0.38 / 232.62 | 2 | 2 |
4 | 7 | 2002.72 | 48 | 14.99 | 2380 | 1712 | 2.09 / 234.33 | 2 | 2 |
5 | 13 | 1324.96 | 31 | 15.03 | 1721 | 802 | 2.90 / 235.13 | 2 | 2 |
6 | 13 | 655.04 | 31 | 15.13 | 1043 | 489 | 3.39 / 235.62 | 2 | 2 |
7 | 13 | 158.88 | 31 | 15.23 | 525 | 248 | 3.63 / 235.87 | 2 | 2 |
8 | 13 | 51.36 | 31 | 15.25 | 379 | 179 | 3.81 / 236.05 | 2 | 2 |
9 | 8 | 0.16 | 175 | 15.23 | 292 | 778 | 4.59 / 236.82 | 2 | 6 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 40 | 15.22 | 410 | 250 | 0.25 / 227.76 | 2 | 2 |
2 | 3 | 973.08 | -1 | 15.59 | 0 | 0 | 0.00 / 227.76 | 2 | 2 |
3 | 12 | 1151.24 | 5 | 15.37 | 1584 | 122 | 0.37 / 227.88 | 2 | 2 |
4 | 7 | 2003.52 | 47 | 14.99 | 2380 | 1677 | 2.05 / 229.56 | 2 | 2 |
5 | 13 | 1485.72 | 31 | 15.00 | 1874 | 871 | 2.92 / 230.43 | 2 | 2 |
6 | 13 | 756.88 | 31 | 15.12 | 1133 | 531 | 3.45 / 230.96 | 2 | 2 |
7 | 13 | 204.52 | 31 | 15.22 | 578 | 273 | 3.72 / 231.23 | 2 | 2 |
8 | 13 | 74.04 | 31 | 15.25 | 405 | 191 | 3.91 / 231.42 | 2 | 3 |
9 | 8 | 0.16 | 175 | 15.23 | 304 | 810 | 4.73 / 232.23 | 2 | 5 |
Average= | 4.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 40 | 15.21 | 400 | 243 | 0.24 / 222.99 | 2 | 2 |
2 | 12 | 1155.68 | 5 | 15.36 | 1539 | 118 | 0.36 / 223.11 | 2 | 2 |
3 | 7 | 2002.56 | 47 | 14.99 | 2394 | 1687 | 2.05 / 224.80 | 2 | 2 |
4 | 13 | 1486.56 | 31 | 15.01 | 1857 | 864 | 2.91 / 225.66 | 2 | 2 |
5 | 13 | 758.48 | 31 | 15.09 | 1183 | 553 | 3.47 / 226.21 | 2 | 2 |
6 | 13 | 135.32 | 31 | 15.25 | 491 | 232 | 3.70 / 226.45 | 2 | 3 |
7 | 13 | 58.64 | 31 | 15.26 | 389 | 184 | 3.88 / 226.63 | 2 | 3 |
8 | 8 | 0.08 | 175 | 15.24 | 303 | 808 | 4.69 / 227.44 | 2 | 8 |
9 | 14 | 0.08 | 15 | 15.22 | 307 | 70 | 4.76 / 227.51 | 2 | 7 |
Average= | 4.29 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.96 | 40 | 15.23 | 403 | 246 | 0.25 / 218.27 | 2 | 2 |
2 | 12 | 1158.84 | 5 | 15.35 | 1640 | 126 | 0.37 / 218.39 | 2 | 2 |
3 | 7 | 2003.00 | 47 | 14.98 | 2410 | 1697 | 2.07 / 220.09 | 2 | 2 |
4 | 13 | 1488.44 | 31 | 15.03 | 1819 | 848 | 2.92 / 220.94 | 2 | 2 |
5 | 13 | 781.36 | 31 | 15.11 | 1152 | 540 | 3.46 / 221.48 | 2 | 2 |
6 | 13 | 220.76 | 31 | 15.22 | 597 | 282 | 3.74 / 221.76 | 2 | 2 |
7 | 13 | 67.52 | 31 | 15.26 | 400 | 189 | 3.93 / 221.95 | 2 | 3 |
8 | 8 | 0.12 | 175 | 15.24 | 300 | 800 | 4.73 / 222.75 | 2 | 5 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 40 | 15.22 | 420 | 256 | 0.26 / 213.60 | 2 | 2 |
2 | 12 | 1162.08 | 5 | 15.44 | 1502 | 116 | 0.37 / 213.71 | 2 | 2 |
3 | 7 | 2001.20 | 47 | 15.01 | 2346 | 1655 | 2.03 / 215.37 | 2 | 2 |
4 | 13 | 1476.44 | 31 | 15.04 | 1808 | 843 | 2.87 / 216.21 | 2 | 2 |
5 | 13 | 777.68 | 31 | 15.13 | 1133 | 531 | 3.40 / 216.74 | 2 | 2 |
6 | 13 | 141.88 | 31 | 15.26 | 499 | 236 | 3.64 / 216.98 | 2 | 3 |
7 | 13 | 59.24 | 31 | 15.27 | 388 | 184 | 3.82 / 217.16 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.25 | 297 | 793 | 4.61 / 217.96 | 2 | 8 |
9 | 14 | 0.16 | 15 | 15.23 | 293 | 67 | 4.68 / 218.02 | 3 | 6 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.80 | 40 | 15.23 | 396 | 241 | 0.24 / 208.90 | 2 | 2 |
2 | 12 | 1147.08 | 5 | 15.47 | 1437 | 111 | 0.35 / 209.01 | 2 | 2 |
3 | 7 | 2002.96 | 47 | 15.01 | 2320 | 1637 | 1.99 / 210.65 | 2 | 2 |
4 | 13 | 1471.12 | 31 | 15.04 | 1826 | 851 | 2.84 / 211.50 | 2 | 2 |
5 | 13 | 775.76 | 31 | 15.13 | 1145 | 537 | 3.38 / 212.04 | 2 | 2 |
6 | 13 | 227.68 | 31 | 15.23 | 600 | 283 | 3.66 / 212.32 | 2 | 2 |
7 | 13 | 72.80 | 31 | 15.26 | 416 | 197 | 3.86 / 212.52 | 2 | 3 |
8 | 8 | 0.12 | 175 | 15.25 | 309 | 825 | 4.68 / 213.34 | 2 | 5 |
Average= | 4.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 40 | 15.24 | 401 | 244 | 0.24 / 204.28 | 2 | 2 |
2 | 12 | 1149.28 | 5 | 15.37 | 1616 | 124 | 0.37 / 204.41 | 2 | 2 |
3 | 7 | 2005.76 | 48 | 15.01 | 2356 | 1697 | 2.07 / 206.11 | 2 | 2 |
4 | 13 | 1495.20 | 31 | 15.04 | 1819 | 848 | 2.91 / 206.95 | 2 | 2 |
5 | 13 | 650.00 | 31 | 15.16 | 1023 | 481 | 3.39 / 207.44 | 2 | 2 |
6 | 13 | 165.96 | 31 | 15.26 | 526 | 249 | 3.64 / 207.68 | 2 | 2 |
7 | 13 | 67.28 | 31 | 15.28 | 398 | 189 | 3.83 / 207.87 | 2 | 3 |
8 | 8 | 0.08 | 175 | 15.26 | 295 | 788 | 4.62 / 208.66 | 2 | 6 |
Average= | 4.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 40 | 15.23 | 412 | 251 | 0.25 / 199.73 | 2 | 2 |
2 | 12 | 1169.04 | 5 | 15.39 | 1570 | 121 | 0.37 / 199.85 | 2 | 2 |
3 | 7 | 2003.48 | 47 | 15.00 | 2351 | 1657 | 2.03 / 201.50 | 2 | 2 |
4 | 13 | 1490.00 | 31 | 15.05 | 1788 | 834 | 2.86 / 202.34 | 2 | 2 |
5 | 13 | 652.56 | 31 | 15.17 | 1026 | 482 | 3.35 / 202.82 | 2 | 2 |
6 | 13 | 170.52 | 31 | 15.27 | 515 | 244 | 3.59 / 203.06 | 2 | 2 |
7 | 13 | 73.16 | 31 | 15.28 | 401 | 190 | 3.78 / 203.25 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.27 | 294 | 786 | 4.57 / 204.04 | 2 | 6 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 40 | 15.25 | 399 | 243 | 0.24 / 195.05 | 2 | 2 |
2 | 12 | 1144.64 | 5 | 15.41 | 1527 | 118 | 0.36 / 195.17 | 2 | 2 |
3 | 7 | 2001.56 | 47 | 15.02 | 2340 | 1652 | 2.01 / 196.82 | 2 | 2 |
4 | 13 | 1477.20 | 31 | 15.06 | 1820 | 850 | 2.86 / 197.67 | 2 | 2 |
5 | 13 | 782.96 | 31 | 15.14 | 1136 | 533 | 3.40 / 198.21 | 2 | 2 |
6 | 13 | 226.44 | 31 | 15.25 | 585 | 277 | 3.67 / 198.48 | 2 | 3 |
7 | 13 | 68.68 | 31 | 15.28 | 411 | 195 | 3.87 / 198.68 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.26 | 299 | 798 | 4.67 / 199.47 | 2 | 7 |
Average= | 4.24 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 40 | 15.24 | 415 | 253 | 0.25 / 190.50 | 2 | 2 |
2 | 12 | 1176.36 | 5 | 15.37 | 1571 | 121 | 0.37 / 190.62 | 2 | 2 |
3 | 7 | 2005.96 | 47 | 15.02 | 2351 | 1660 | 2.03 / 192.28 | 2 | 2 |
4 | 13 | 1361.96 | 31 | 15.07 | 1704 | 796 | 2.83 / 193.08 | 2 | 2 |
5 | 13 | 713.28 | 31 | 15.16 | 1070 | 503 | 3.33 / 193.58 | 2 | 2 |
6 | 13 | 184.84 | 31 | 15.26 | 545 | 258 | 3.59 / 193.84 | 2 | 3 |
7 | 13 | 73.20 | 31 | 15.29 | 396 | 188 | 3.78 / 194.02 | 2 | 2 |
8 | 8 | 0.28 | 175 | 15.27 | 294 | 786 | 4.56 / 194.81 | 2 | 5 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 40 | 15.26 | 405 | 247 | 0.25 / 185.83 | 2 | 2 |
2 | 12 | 1169.44 | 5 | 15.50 | 1428 | 111 | 0.36 / 185.95 | 2 | 2 |
3 | 7 | 2002.76 | 47 | 15.05 | 2298 | 1625 | 1.98 / 187.57 | 2 | 2 |
4 | 13 | 1505.16 | 31 | 15.05 | 1837 | 857 | 2.84 / 188.43 | 2 | 2 |
5 | 13 | 785.04 | 31 | 15.15 | 1133 | 532 | 3.37 / 188.96 | 2 | 2 |
6 | 13 | 238.28 | 31 | 15.25 | 594 | 281 | 3.65 / 189.24 | 2 | 2 |
7 | 13 | 69.48 | 31 | 15.29 | 407 | 193 | 3.85 / 189.43 | 2 | 2 |
8 | 8 | 0.00 | 175 | 15.27 | 304 | 812 | 4.66 / 190.25 | 2 | 6 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 40 | 15.25 | 422 | 257 | 0.26 / 181.20 | 2 | 2 |
2 | 12 | 1154.84 | 5 | 15.38 | 1599 | 123 | 0.38 / 181.33 | 2 | 2 |
3 | 7 | 2003.64 | 47 | 15.03 | 2333 | 1648 | 2.03 / 182.97 | 2 | 2 |
4 | 13 | 1472.56 | 31 | 15.07 | 1794 | 838 | 2.87 / 183.81 | 2 | 2 |
5 | 13 | 787.72 | 31 | 15.15 | 1137 | 534 | 3.40 / 184.35 | 2 | 2 |
6 | 13 | 154.20 | 31 | 15.29 | 505 | 239 | 3.64 / 184.59 | 2 | 2 |
7 | 13 | 62.64 | 31 | 15.30 | 392 | 186 | 3.83 / 184.77 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.28 | 305 | 816 | 4.64 / 185.59 | 2 | 7 |
Average= | 4.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 40 | 15.24 | 419 | 255 | 0.26 / 176.50 | 2 | 2 |
2 | 12 | 1164.80 | 5 | 15.38 | 1555 | 120 | 0.38 / 176.62 | 2 | 2 |
3 | 7 | 2002.60 | 47 | 15.02 | 2343 | 1654 | 2.03 / 178.27 | 2 | 2 |
4 | 13 | 1464.04 | 31 | 15.05 | 1818 | 848 | 2.88 / 179.12 | 2 | 2 |
5 | 13 | 734.04 | 31 | 15.16 | 1110 | 522 | 3.40 / 179.64 | 2 | 2 |
6 | 13 | 195.76 | 31 | 15.27 | 565 | 267 | 3.67 / 179.91 | 2 | 3 |
7 | 13 | 64.80 | 31 | 15.30 | 413 | 196 | 3.86 / 180.11 | 2 | 2 |
8 | 8 | 0.12 | 175 | 15.27 | 314 | 839 | 4.70 / 180.95 | 2 | 6 |
Average= | 4.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 41 | 15.25 | 411 | 257 | 0.26 / 171.78 | 2 | 2 |
2 | 12 | 1153.04 | 5 | 15.38 | 1596 | 123 | 0.38 / 171.90 | 2 | 2 |
3 | 7 | 2001.40 | 47 | 15.05 | 2304 | 1630 | 2.01 / 173.53 | 2 | 2 |
4 | 13 | 1483.00 | 31 | 15.08 | 1797 | 840 | 2.85 / 174.37 | 2 | 2 |
5 | 13 | 781.24 | 31 | 15.16 | 1122 | 527 | 3.38 / 174.90 | 2 | 2 |
6 | 13 | 234.64 | 31 | 15.26 | 619 | 293 | 3.67 / 175.19 | 2 | 2 |
7 | 13 | 72.04 | 31 | 15.30 | 422 | 200 | 3.87 / 175.39 | 2 | 2 |
8 | 8 | 0.16 | 175 | 15.27 | 320 | 855 | 4.72 / 176.24 | 2 | 5 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 42 | 15.27 | 402 | 258 | 0.26 / 167.12 | 2 | 2 |
2 | 3 | 966.32 | -1 | 15.62 | 0 | 0 | 0.00 / 167.12 | 2 | 2 |
3 | 12 | 1158.20 | 5 | 15.40 | 1522 | 117 | 0.38 / 167.23 | 2 | 2 |
4 | 7 | 2005.64 | 47 | 15.07 | 2268 | 1606 | 1.98 / 168.84 | 2 | 2 |
5 | 13 | 1493.88 | 31 | 15.08 | 1796 | 840 | 2.82 / 169.68 | 2 | 2 |
6 | 13 | 783.64 | 31 | 15.16 | 1134 | 533 | 3.35 / 170.21 | 2 | 2 |
7 | 13 | 249.64 | 31 | 15.26 | 619 | 293 | 3.65 / 170.51 | 2 | 2 |
8 | 13 | 69.64 | 31 | 15.30 | 401 | 190 | 3.84 / 170.70 | 2 | 2 |
9 | 8 | 0.24 | 175 | 15.28 | 308 | 824 | 4.66 / 171.52 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 42 | 15.26 | 397 | 254 | 0.25 / 162.56 | 2 | 2 |
2 | 12 | 1154.60 | 5 | 15.43 | 1415 | 109 | 0.36 / 162.67 | 2 | 2 |
3 | 7 | 2002.84 | 47 | 15.06 | 2230 | 1578 | 1.94 / 164.25 | 2 | 2 |
4 | 13 | 1492.84 | 31 | 15.06 | 1844 | 861 | 2.80 / 165.11 | 2 | 2 |
5 | 13 | 816.56 | 31 | 15.18 | 1130 | 532 | 3.33 / 165.64 | 2 | 2 |
6 | 13 | 171.56 | 31 | 15.30 | 515 | 244 | 3.58 / 165.89 | 2 | 2 |
7 | 13 | 67.64 | 31 | 15.31 | 393 | 187 | 3.77 / 166.07 | 2 | 2 |
8 | 8 | 0.04 | 175 | 15.29 | 294 | 787 | 4.55 / 166.86 | 2 | 5 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.40 | 42 | 15.26 | 407 | 261 | 0.26 / 158.06 | 2 | 2 |
2 | 12 | 1179.48 | 5 | 15.46 | 1393 | 108 | 0.37 / 158.17 | 2 | 2 |
3 | 7 | 2003.24 | 47 | 15.05 | 2259 | 1598 | 1.97 / 159.76 | 2 | 2 |
4 | 13 | 1358.04 | 31 | 15.11 | 1649 | 772 | 2.74 / 160.54 | 2 | 2 |
5 | 13 | 821.76 | 31 | 15.16 | 1156 | 543 | 3.28 / 161.08 | 2 | 2 |
6 | 13 | 166.96 | 31 | 15.30 | 515 | 244 | 3.53 / 161.32 | 2 | 2 |
7 | 13 | 90.72 | 31 | 15.31 | 418 | 198 | 3.72 / 161.52 | 2 | 3 |
8 | 8 | 0.20 | 175 | 15.29 | 293 | 784 | 4.51 / 162.31 | 2 | 3 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 42 | 15.27 | 409 | 262 | 0.26 / 153.46 | 2 | 2 |
2 | 12 | 1171.80 | 5 | 15.42 | 1549 | 119 | 0.38 / 153.58 | 2 | 2 |
3 | 7 | 2001.76 | 47 | 15.08 | 2251 | 1595 | 1.98 / 155.18 | 2 | 2 |
4 | 13 | 1490.16 | 31 | 15.15 | 1715 | 805 | 2.78 / 155.98 | 2 | 2 |
5 | 13 | 793.76 | 31 | 15.18 | 1119 | 527 | 3.31 / 156.51 | 2 | 2 |
6 | 13 | 250.56 | 31 | 15.28 | 607 | 288 | 3.60 / 156.80 | 2 | 3 |
7 | 13 | 77.72 | 31 | 15.31 | 408 | 194 | 3.79 / 156.99 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.29 | 302 | 808 | 4.60 / 157.80 | 2 | 5 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.16 | 42 | 15.28 | 397 | 255 | 0.25 / 148.78 | 2 | 2 |
2 | 3 | 1015.80 | 1 | 15.37 | 1485 | 23 | 0.28 / 148.80 | 2 | 2 |
3 | 12 | 1153.32 | 5 | 15.50 | 1423 | 110 | 0.39 / 148.91 | 2 | 2 |
4 | 7 | 2002.24 | 47 | 15.07 | 2249 | 1593 | 1.98 / 150.51 | 2 | 2 |
5 | 13 | 1502.92 | 31 | 15.09 | 1811 | 847 | 2.83 / 151.36 | 2 | 2 |
6 | 13 | 812.16 | 31 | 15.18 | 1148 | 540 | 3.37 / 151.90 | 2 | 2 |
7 | 13 | 263.56 | 31 | 15.27 | 629 | 298 | 3.67 / 152.19 | 2 | 3 |
8 | 13 | 84.16 | 31 | 15.31 | 423 | 201 | 3.87 / 152.39 | 2 | 3 |
9 | 8 | 0.16 | 175 | 15.30 | 301 | 806 | 4.67 / 153.20 | 2 | 6 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 42 | 15.28 | 399 | 256 | 0.26 / 144.33 | 2 | 2 |
2 | 12 | 1156.00 | 5 | 15.52 | 1434 | 111 | 0.37 / 144.44 | 2 | 2 |
3 | 7 | 2005.20 | 47 | 15.08 | 2251 | 1595 | 1.96 / 146.04 | 2 | 2 |
4 | 13 | 1351.04 | 31 | 15.11 | 1665 | 780 | 2.74 / 146.82 | 2 | 2 |
5 | 13 | 691.16 | 31 | 15.21 | 1020 | 481 | 3.22 / 147.30 | 2 | 2 |
6 | 13 | 197.04 | 31 | 15.30 | 546 | 259 | 3.48 / 147.56 | 2 | 2 |
7 | 13 | 69.32 | 31 | 15.32 | 390 | 185 | 3.67 / 147.74 | 2 | 2 |
8 | 8 | 0.08 | 175 | 15.31 | 292 | 782 | 4.45 / 148.53 | 2 | 5 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 42 | 15.29 | 405 | 260 | 0.26 / 139.67 | 2 | 2 |
2 | 12 | 1171.16 | 5 | 15.40 | 1595 | 123 | 0.38 / 139.79 | 2 | 2 |
3 | 7 | 2003.40 | 47 | 15.08 | 2257 | 1600 | 1.98 / 141.39 | 2 | 2 |
4 | 13 | 1658.76 | 31 | 15.09 | 1933 | 904 | 2.89 / 142.30 | 2 | 2 |
5 | 13 | 778.24 | 31 | 15.20 | 1096 | 516 | 3.40 / 142.81 | 2 | 2 |
6 | 13 | 241.96 | 31 | 15.29 | 591 | 280 | 3.68 / 143.09 | 2 | 2 |
7 | 13 | 77.88 | 31 | 15.32 | 410 | 195 | 3.88 / 143.29 | 2 | 3 |
8 | 8 | 0.16 | 175 | 15.31 | 294 | 788 | 4.67 / 144.08 | 2 | 5 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 42 | 15.30 | 380 | 244 | 0.24 / 135.12 | 2 | 2 |
2 | 12 | 1146.08 | 5 | 15.44 | 1428 | 110 | 0.35 / 135.23 | 2 | 2 |
3 | 7 | 2002.20 | 47 | 15.08 | 2254 | 1598 | 1.95 / 136.83 | 2 | 2 |
4 | 13 | 1353.44 | 31 | 15.12 | 1619 | 759 | 2.71 / 137.58 | 2 | 2 |
5 | 13 | 847.88 | 31 | 15.18 | 1179 | 555 | 3.27 / 138.14 | 2 | 2 |
6 | 13 | 183.32 | 31 | 15.31 | 534 | 253 | 3.52 / 138.39 | 2 | 2 |
7 | 13 | 97.48 | 31 | 15.32 | 440 | 209 | 3.73 / 138.60 | 2 | 3 |
8 | 8 | 0.04 | 175 | 15.31 | 302 | 809 | 4.54 / 139.41 | 2 | 6 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 42 | 15.29 | 401 | 258 | 0.26 / 130.59 | 2 | 2 |
2 | 12 | 1297.40 | 5 | 15.40 | 1692 | 130 | 0.39 / 130.72 | 2 | 2 |
3 | 7 | 2004.76 | 42 | 15.09 | 2283 | 1447 | 1.83 / 132.17 | 2 | 2 |
4 | 13 | 1523.64 | 26 | 15.11 | 1834 | 721 | 2.56 / 132.89 | 2 | 2 |
5 | 13 | 1023.08 | 26 | 15.16 | 1353 | 533 | 3.09 / 133.42 | 2 | 2 |
6 | 13 | 361.96 | 26 | 15.27 | 742 | 295 | 3.38 / 133.72 | 2 | 2 |
7 | 13 | 128.72 | 26 | 15.33 | 457 | 182 | 3.57 / 133.90 | 2 | 2 |
8 | 13 | 73.08 | 26 | 15.33 | 383 | 153 | 3.72 / 134.05 | 2 | 3 |
9 | 8 | 0.24 | 175 | 15.32 | 282 | 756 | 4.47 / 134.81 | 2 | 6 |
10 | 14 | 0.24 | 15 | 15.30 | 283 | 65 | 4.54 / 134.87 | 2 | 5 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 42 | 15.30 | 393 | 253 | 0.25 / 126.15 | 2 | 2 |
2 | 12 | 1308.20 | 5 | 15.44 | 1529 | 118 | 0.37 / 126.27 | 2 | 2 |
3 | 7 | 2003.52 | 42 | 15.11 | 2224 | 1411 | 1.78 / 127.68 | 2 | 2 |
4 | 13 | 1527.60 | 26 | 15.24 | 1650 | 654 | 2.44 / 128.34 | 2 | 2 |
5 | 13 | 1032.84 | 26 | 15.17 | 1331 | 525 | 2.96 / 128.86 | 2 | 2 |
6 | 13 | 524.48 | 26 | 15.25 | 878 | 348 | 3.31 / 129.21 | 2 | 2 |
7 | 13 | 138.60 | 26 | 15.33 | 474 | 189 | 3.50 / 129.40 | 2 | 2 |
8 | 13 | 89.80 | 26 | 15.34 | 403 | 161 | 3.66 / 129.56 | 2 | 2 |
9 | 8 | 0.16 | 175 | 15.32 | 289 | 775 | 4.43 / 130.34 | 2 | 4 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 42 | 15.30 | 381 | 245 | 0.24 / 121.66 | 2 | 2 |
2 | 12 | 1137.92 | 5 | 15.53 | 1342 | 104 | 0.35 / 121.77 | 2 | 2 |
3 | 7 | 2002.36 | 42 | 15.10 | 2250 | 1427 | 1.78 / 123.19 | 2 | 2 |
4 | 13 | 1522.88 | 26 | 15.15 | 1759 | 693 | 2.47 / 123.89 | 2 | 2 |
5 | 13 | 1029.88 | 26 | 15.18 | 1319 | 521 | 2.99 / 124.41 | 2 | 2 |
6 | 13 | 510.36 | 26 | 15.25 | 862 | 342 | 3.33 / 124.75 | 2 | 2 |
7 | 13 | 165.56 | 26 | 15.32 | 516 | 206 | 3.54 / 124.95 | 2 | 2 |
8 | 13 | 102.96 | 26 | 15.33 | 425 | 169 | 3.71 / 125.12 | 2 | 2 |
9 | 8 | -0.04 | 175 | 15.32 | 290 | 777 | 4.48 / 125.90 | 2 | 5 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 42 | 15.32 | 378 | 243 | 0.24 / 117.17 | 2 | 2 |
2 | 12 | 1148.72 | 5 | 15.42 | 1562 | 120 | 0.36 / 117.29 | 2 | 2 |
3 | 7 | 2007.16 | 42 | 15.10 | 2270 | 1440 | 1.80 / 118.73 | 2 | 2 |
4 | 13 | 1522.44 | 26 | 15.09 | 1899 | 745 | 2.55 / 119.47 | 2 | 2 |
5 | 13 | 1043.72 | 26 | 15.17 | 1361 | 537 | 3.09 / 120.01 | 2 | 2 |
6 | 13 | 390.04 | 26 | 15.28 | 755 | 300 | 3.39 / 120.31 | 2 | 2 |
7 | 13 | 140.28 | 26 | 15.33 | 464 | 185 | 3.57 / 120.49 | 2 | 2 |
8 | 13 | 80.56 | 26 | 15.34 | 392 | 156 | 3.73 / 120.65 | 2 | 3 |
9 | 8 | 0.08 | 175 | 15.32 | 287 | 769 | 4.50 / 121.42 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.40 | 40 | 15.30 | 398 | 244 | 0.24 / 112.71 | 2 | 2 |
2 | 3 | 1045.40 | 1 | 15.36 | 1443 | 22 | 0.27 / 112.73 | 2 | 2 |
3 | 3 | 1020.52 | 1 | 15.46 | 1265 | 20 | 0.29 / 112.75 | 2 | 2 |
4 | 12 | 1161.32 | 5 | 15.43 | 1520 | 117 | 0.40 / 112.87 | 2 | 2 |
5 | 7 | 2003.36 | 42 | 15.12 | 2207 | 1402 | 1.80 / 114.27 | 2 | 2 |
6 | 13 | 1672.20 | 26 | 15.16 | 1859 | 733 | 2.54 / 115.00 | 2 | 2 |
7 | 13 | 1018.04 | 26 | 15.19 | 1317 | 520 | 3.06 / 115.52 | 2 | 2 |
8 | 13 | 375.20 | 26 | 15.29 | 726 | 289 | 3.35 / 115.81 | 2 | 2 |
9 | 13 | 137.44 | 26 | 15.34 | 460 | 183 | 3.53 / 116.00 | 2 | 2 |
10 | 13 | 77.36 | 26 | 15.35 | 392 | 156 | 3.69 / 116.15 | 2 | 2 |
11 | 8 | 0.16 | 175 | 15.33 | 287 | 770 | 4.46 / 116.92 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 40 | 15.31 | 410 | 251 | 0.25 / 108.14 | 2 | 2 |
2 | 12 | 1158.08 | 5 | 15.51 | 1471 | 114 | 0.37 / 108.25 | 2 | 2 |
3 | 7 | 2002.16 | 42 | 15.10 | 2267 | 1438 | 1.80 / 109.69 | 2 | 2 |
4 | 13 | 1519.80 | 26 | 15.11 | 1873 | 736 | 2.54 / 110.42 | 2 | 2 |
5 | 13 | 1014.04 | 26 | 15.19 | 1337 | 528 | 3.07 / 110.95 | 2 | 2 |
6 | 13 | 481.88 | 26 | 15.26 | 855 | 339 | 3.41 / 111.29 | 2 | 2 |
7 | 13 | 152.48 | 26 | 15.33 | 506 | 202 | 3.61 / 111.49 | 2 | 3 |
8 | 13 | 87.12 | 26 | 15.34 | 421 | 168 | 3.78 / 111.66 | 2 | 2 |
9 | 8 | 0.28 | 175 | 15.32 | 301 | 807 | 4.58 / 112.47 | 2 | 7 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.96 | 40 | 15.31 | 385 | 236 | 0.24 / 103.66 | 2 | 2 |
2 | 12 | 1299.88 | 5 | 15.49 | 1475 | 114 | 0.35 / 103.77 | 2 | 2 |
3 | 7 | 2002.96 | 42 | 15.10 | 2286 | 1450 | 1.80 / 105.22 | 2 | 2 |
4 | 13 | 1513.68 | 26 | 15.20 | 1735 | 686 | 2.49 / 105.91 | 2 | 2 |
5 | 13 | 1029.92 | 26 | 15.18 | 1355 | 535 | 3.02 / 106.44 | 2 | 2 |
6 | 13 | 366.60 | 26 | 15.29 | 731 | 291 | 3.31 / 106.73 | 2 | 2 |
7 | 13 | 145.96 | 26 | 15.34 | 492 | 196 | 3.51 / 106.93 | 2 | 2 |
8 | 13 | 93.40 | 26 | 15.35 | 414 | 165 | 3.67 / 107.09 | 2 | 2 |
9 | 8 | 0.24 | 175 | 15.33 | 295 | 791 | 4.46 / 107.88 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 40 | 15.33 | 383 | 235 | 0.23 / 99.10 | 2 | 2 |
2 | 12 | 1163.92 | 5 | 15.44 | 1594 | 123 | 0.36 / 99.22 | 2 | 2 |
3 | 7 | 2012.24 | 42 | 15.12 | 2229 | 1416 | 1.77 / 100.64 | 2 | 2 |
4 | 13 | 1540.72 | 26 | 15.18 | 1787 | 705 | 2.48 / 101.34 | 2 | 2 |
5 | 13 | 1192.44 | 26 | 15.16 | 1498 | 590 | 3.07 / 101.93 | 2 | 2 |
6 | 13 | 475.52 | 26 | 15.27 | 845 | 335 | 3.40 / 102.27 | 2 | 2 |
7 | 13 | 159.68 | 26 | 15.34 | 502 | 200 | 3.60 / 102.47 | 2 | 2 |
8 | 13 | 94.80 | 26 | 15.34 | 424 | 169 | 3.77 / 102.64 | 2 | 2 |
9 | 8 | 0.20 | 175 | 15.34 | 292 | 784 | 4.56 / 103.42 | 2 | 5 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 40 | 15.32 | 397 | 243 | 0.24 / 94.72 | 2 | 2 |
2 | 12 | 1164.76 | 5 | 15.56 | 1395 | 109 | 0.35 / 94.83 | 2 | 2 |
3 | 7 | 2001.04 | 42 | 15.16 | 2204 | 1403 | 1.76 / 96.23 | 2 | 2 |
4 | 13 | 1506.20 | 26 | 15.16 | 1810 | 713 | 2.47 / 96.95 | 2 | 2 |
5 | 13 | 985.52 | 26 | 15.21 | 1316 | 520 | 2.99 / 97.47 | 2 | 2 |
6 | 13 | 334.08 | 26 | 15.31 | 695 | 277 | 3.27 / 97.74 | 2 | 2 |
7 | 13 | 139.92 | 26 | 15.36 | 467 | 187 | 3.45 / 97.93 | 2 | 2 |
8 | 13 | 84.92 | 26 | 15.36 | 401 | 160 | 3.61 / 98.09 | 2 | 2 |
9 | 8 | 0.16 | 175 | 15.35 | 288 | 774 | 4.39 / 98.86 | 2 | 4 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 40 | 15.31 | 407 | 249 | 0.25 / 90.12 | 2 | 2 |
2 | 12 | 1169.40 | 5 | 15.44 | 1607 | 124 | 0.37 / 90.24 | 2 | 2 |
3 | 7 | 2002.84 | 43 | 15.12 | 2309 | 1501 | 1.87 / 91.74 | 2 | 2 |
4 | 13 | 1665.88 | 26 | 15.13 | 1971 | 775 | 2.65 / 92.52 | 2 | 2 |
5 | 13 | 957.84 | 26 | 15.21 | 1278 | 505 | 3.16 / 93.02 | 2 | 2 |
6 | 13 | 437.72 | 26 | 15.30 | 803 | 319 | 3.47 / 93.34 | 2 | 2 |
7 | 13 | 144.04 | 26 | 15.35 | 478 | 191 | 3.67 / 93.53 | 2 | 2 |
8 | 13 | 80.76 | 26 | 15.36 | 401 | 160 | 3.83 / 93.70 | 2 | 3 |
9 | 8 | 0.08 | 175 | 15.35 | 291 | 782 | 4.61 / 94.48 | 2 | 7 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.72 | 40 | 15.33 | 397 | 243 | 0.24 / 85.49 | 2 | 2 |
2 | 12 | 1167.76 | 5 | 15.45 | 1600 | 124 | 0.37 / 85.62 | 2 | 2 |
3 | 7 | 2001.88 | 42 | 15.14 | 2249 | 1430 | 1.80 / 87.05 | 2 | 2 |
4 | 13 | 1522.92 | 26 | 15.14 | 1879 | 740 | 2.54 / 87.79 | 2 | 2 |
5 | 13 | 1186.32 | 26 | 15.18 | 1485 | 586 | 3.12 / 88.37 | 2 | 2 |
6 | 13 | 458.48 | 26 | 15.29 | 820 | 326 | 3.45 / 88.70 | 2 | 2 |
7 | 13 | 145.36 | 26 | 15.35 | 494 | 197 | 3.65 / 88.90 | 2 | 2 |
8 | 13 | 77.80 | 26 | 15.36 | 415 | 166 | 3.81 / 89.06 | 2 | 2 |
9 | 8 | 0.20 | 175 | 15.34 | 301 | 808 | 4.62 / 89.87 | 2 | 4 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 40 | 15.33 | 404 | 248 | 0.25 / 80.88 | 2 | 2 |
2 | 12 | 1162.88 | 3 | 15.46 | 1614 | 75 | 0.32 / 80.96 | 2 | 2 |
3 | 7 | 2001.76 | 40 | 15.15 | 2262 | 1371 | 1.69 / 82.33 | 2 | 2 |
4 | 13 | 1675.28 | 26 | 15.14 | 1945 | 766 | 2.46 / 83.09 | 2 | 2 |
5 | 13 | 1149.92 | 26 | 15.19 | 1454 | 574 | 3.03 / 83.67 | 2 | 2 |
6 | 13 | 619.48 | 26 | 15.27 | 971 | 386 | 3.42 / 84.05 | 2 | 2 |
7 | 13 | 148.68 | 26 | 15.36 | 499 | 199 | 3.62 / 84.25 | 2 | 2 |
8 | 13 | 86.04 | 26 | 15.36 | 428 | 171 | 3.79 / 84.42 | 2 | 3 |
9 | 8 | 0.16 | 175 | 15.35 | 307 | 825 | 4.61 / 85.25 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 41 | 15.34 | 395 | 248 | 0.25 / 76.43 | 2 | 2 |
2 | 12 | 1150.72 | 3 | 15.48 | 1509 | 70 | 0.32 / 76.50 | 2 | 2 |
3 | 7 | 2006.52 | 40 | 15.15 | 2294 | 1390 | 1.71 / 77.89 | 2 | 2 |
4 | 13 | 1680.20 | 26 | 15.15 | 1969 | 776 | 2.48 / 78.67 | 2 | 2 |
5 | 13 | 1010.84 | 26 | 15.22 | 1343 | 531 | 3.02 / 79.20 | 2 | 2 |
6 | 13 | 368.44 | 26 | 15.32 | 743 | 296 | 3.31 / 79.50 | 2 | 2 |
7 | 13 | 126.92 | 26 | 15.37 | 470 | 188 | 3.50 / 79.68 | 2 | 2 |
8 | 13 | 72.80 | 26 | 15.37 | 395 | 158 | 3.66 / 79.84 | 2 | 3 |
9 | 8 | 0.04 | 175 | 15.35 | 296 | 795 | 4.45 / 80.64 | 2 | 6 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 39 | 15.33 | 397 | 237 | 0.24 / 71.91 | 2 | 2 |
2 | 10 | 1025.84 | 2 | 15.37 | 1403 | 43 | 0.28 / 71.95 | 2 | 2 |
3 | 3 | 1024.28 | 1 | 15.40 | 1440 | 22 | 0.30 / 71.97 | 2 | 2 |
4 | 12 | 1174.52 | 3 | 15.57 | 1384 | 65 | 0.37 / 72.04 | 2 | 2 |
5 | 7 | 2003.92 | 34 | 15.19 | 2220 | 1147 | 1.51 / 73.18 | 2 | 2 |
6 | 13 | 1851.72 | 23 | 15.15 | 2136 | 744 | 2.26 / 73.93 | 2 | 2 |
7 | 13 | 1326.12 | 23 | 15.19 | 1614 | 564 | 2.82 / 74.49 | 2 | 2 |
8 | 13 | 807.36 | 23 | 15.24 | 1147 | 402 | 3.22 / 74.89 | 2 | 2 |
9 | 13 | 299.92 | 23 | 15.33 | 661 | 233 | 3.46 / 75.13 | 2 | 3 |
10 | 13 | 104.48 | 23 | 15.38 | 429 | 152 | 3.61 / 75.28 | 2 | 2 |
11 | 13 | 58.08 | 23 | 15.38 | 376 | 133 | 3.74 / 75.41 | 2 | 3 |
12 | 8 | 0.08 | 175 | 15.36 | 287 | 771 | 4.51 / 76.18 | 2 | 5 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.56 | 37 | 15.35 | 378 | 215 | 0.21 / 67.48 | 2 | 2 |
2 | 10 | 1033.84 | 2 | 15.44 | 1336 | 41 | 0.26 / 67.52 | 2 | 2 |
3 | 3 | 1022.04 | 1 | 15.46 | 1406 | 22 | 0.28 / 67.54 | 2 | 2 |
4 | 12 | 1158.76 | 3 | 15.56 | 1416 | 66 | 0.34 / 67.61 | 2 | 2 |
5 | 7 | 2004.04 | 34 | 15.17 | 2291 | 1182 | 1.53 / 68.79 | 2 | 2 |
6 | 13 | 1699.24 | 23 | 15.14 | 2065 | 719 | 2.24 / 69.51 | 2 | 2 |
7 | 13 | 1224.60 | 23 | 15.20 | 1552 | 543 | 2.79 / 70.05 | 2 | 2 |
8 | 13 | 724.16 | 23 | 15.25 | 1085 | 381 | 3.17 / 70.43 | 2 | 2 |
9 | 13 | 222.00 | 23 | 15.35 | 586 | 207 | 3.37 / 70.64 | 2 | 2 |
10 | 13 | 118.92 | 23 | 15.37 | 439 | 155 | 3.53 / 70.79 | 2 | 2 |
11 | 13 | 36.32 | 23 | 15.38 | 339 | 120 | 3.65 / 70.91 | 2 | 2 |
12 | 8 | 0.12 | 175 | 15.36 | 282 | 758 | 4.41 / 71.67 | 2 | 6 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 33 | 15.36 | 392 | 199 | 0.20 / 62.97 | 2 | 2 |
2 | 10 | 1037.68 | 3 | 15.37 | 1441 | 66 | 0.27 / 63.03 | 2 | 2 |
3 | 3 | 1063.40 | 2 | 15.37 | 1505 | 46 | 0.31 / 63.08 | 2 | 2 |
4 | 3 | 1022.64 | 1 | 15.43 | 1490 | 23 | 0.33 / 63.10 | 2 | 2 |
5 | 12 | 1166.92 | 3 | 15.49 | 1508 | 70 | 0.40 / 63.17 | 2 | 2 |
6 | 7 | 2004.80 | 34 | 15.15 | 2353 | 1212 | 1.62 / 64.39 | 2 | 2 |
7 | 13 | 1684.04 | 23 | 15.14 | 2077 | 723 | 2.34 / 65.11 | 2 | 2 |
8 | 13 | 1206.16 | 23 | 15.18 | 1611 | 562 | 2.90 / 65.67 | 2 | 2 |
9 | 13 | 689.64 | 23 | 15.26 | 1063 | 373 | 3.28 / 66.04 | 2 | 3 |
10 | 13 | 179.08 | 23 | 15.37 | 524 | 185 | 3.46 / 66.23 | 2 | 2 |
11 | 13 | 109.20 | 23 | 15.38 | 428 | 151 | 3.61 / 66.38 | 2 | 2 |
12 | 13 | 58.16 | 23 | 15.38 | 364 | 129 | 3.74 / 66.51 | 2 | 3 |
13 | 8 | 0.08 | 175 | 15.37 | 280 | 753 | 4.49 / 67.26 | 2 | 6 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 33 | 15.36 | 411 | 208 | 0.21 / 58.82 | 2 | 2 |
2 | 12 | 1192.44 | 3 | 15.44 | 1889 | 87 | 0.30 / 58.91 | 2 | 2 |
3 | 7 | 2004.00 | 34 | 15.07 | 2767 | 1418 | 1.71 / 60.33 | 2 | 2 |
4 | 13 | 1507.12 | 23 | 15.11 | 2207 | 767 | 2.48 / 61.10 | 2 | 3 |
5 | 13 | 801.56 | 23 | 15.27 | 1149 | 404 | 2.88 / 61.50 | 2 | 2 |
6 | 13 | 286.44 | 23 | 15.36 | 633 | 224 | 3.11 / 61.72 | 2 | 3 |
7 | 13 | 118.72 | 23 | 15.39 | 438 | 155 | 3.26 / 61.88 | 2 | 2 |
8 | 13 | 66.00 | 23 | 15.40 | 379 | 134 | 3.40 / 62.01 | 2 | 2 |
9 | 8 | 0.16 | 175 | 15.38 | 281 | 756 | 4.15 / 62.77 | 2 | 7 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 32 | 15.36 | 389 | 191 | 0.19 / 54.79 | 2 | 2 |
2 | 12 | 1184.24 | 3 | 15.43 | 1884 | 87 | 0.28 / 54.88 | 2 | 2 |
3 | 7 | 2001.52 | 34 | 15.07 | 2751 | 1410 | 1.69 / 56.29 | 2 | 2 |
4 | 13 | 1483.68 | 23 | 15.12 | 2173 | 756 | 2.44 / 57.05 | 2 | 3 |
5 | 13 | 782.60 | 23 | 15.23 | 1338 | 469 | 2.91 / 57.52 | 2 | 4 |
6 | 13 | 235.12 | 23 | 15.36 | 652 | 230 | 3.14 / 57.75 | 2 | 4 |
7 | 13 | 69.68 | 23 | 15.40 | 399 | 141 | 3.28 / 57.89 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.38 | 287 | 728 | 4.01 / 58.62 | 2 | 9 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.36 | 32 | 15.37 | 392 | 193 | 0.19 / 50.68 | 2 | 2 |
2 | 12 | 1181.48 | 3 | 15.45 | 1861 | 86 | 0.28 / 50.76 | 2 | 2 |
3 | 7 | 2006.24 | 34 | 15.08 | 2743 | 1406 | 1.69 / 52.17 | 2 | 2 |
4 | 13 | 1519.44 | 23 | 15.11 | 2208 | 767 | 2.45 / 52.94 | 2 | 3 |
5 | 13 | 824.48 | 23 | 15.22 | 1401 | 490 | 2.94 / 53.43 | 2 | 4 |
6 | 13 | 166.48 | 23 | 15.38 | 551 | 195 | 3.14 / 53.62 | 2 | 3 |
7 | 13 | 89.32 | 23 | 15.40 | 424 | 150 | 3.29 / 53.77 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.39 | 284 | 721 | 4.01 / 54.50 | 2 | 11 |
9 | 14 | 0.16 | 25 | 15.37 | 281 | 108 | 4.12 / 54.60 | 3 | 12 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 32 | 15.37 | 400 | 197 | 0.20 / 46.68 | 2 | 2 |
2 | 12 | 1176.92 | 3 | 15.45 | 1861 | 86 | 0.28 / 46.76 | 2 | 2 |
3 | 7 | 2002.48 | 34 | 15.08 | 2739 | 1404 | 1.69 / 48.17 | 2 | 2 |
4 | 13 | 1503.40 | 23 | 15.12 | 2185 | 760 | 2.45 / 48.93 | 2 | 3 |
5 | 13 | 801.88 | 23 | 15.23 | 1371 | 480 | 2.93 / 49.41 | 2 | 4 |
6 | 13 | 250.48 | 23 | 15.35 | 673 | 238 | 3.17 / 49.64 | 2 | 4 |
7 | 13 | 79.76 | 23 | 15.40 | 404 | 143 | 3.31 / 49.79 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.39 | 275 | 698 | 4.01 / 50.49 | 2 | 9 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.72 | 32 | 15.37 | 393 | 193 | 0.19 / 42.62 | 2 | 2 |
2 | 12 | 1168.00 | 2 | 15.47 | 1863 | 58 | 0.25 / 42.68 | 2 | 2 |
3 | 7 | 2003.40 | 38 | 15.08 | 2726 | 1562 | 1.81 / 44.24 | 2 | 2 |
4 | 13 | 1476.48 | 22 | 15.13 | 2157 | 718 | 2.53 / 44.96 | 2 | 3 |
5 | 13 | 784.72 | 22 | 15.24 | 1343 | 450 | 2.98 / 45.41 | 2 | 4 |
6 | 13 | 251.48 | 22 | 15.36 | 668 | 226 | 3.21 / 45.63 | 2 | 4 |
7 | 13 | 85.04 | 22 | 15.40 | 414 | 140 | 3.35 / 45.77 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.40 | 278 | 706 | 4.05 / 46.48 | 2 | 11 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 32 | 15.38 | 395 | 194 | 0.19 / 38.67 | 2 | 2 |
2 | 12 | 1182.20 | 2 | 15.47 | 1881 | 58 | 0.25 / 38.72 | 2 | 2 |
3 | 7 | 2006.96 | 38 | 15.07 | 2726 | 1561 | 1.81 / 40.28 | 2 | 2 |
4 | 13 | 1340.92 | 22 | 15.15 | 1987 | 662 | 2.48 / 40.95 | 2 | 3 |
5 | 13 | 809.52 | 22 | 15.23 | 1368 | 458 | 2.93 / 41.41 | 2 | 4 |
6 | 13 | 159.32 | 22 | 15.40 | 530 | 180 | 3.11 / 41.58 | 2 | 3 |
7 | 13 | 95.44 | 22 | 15.40 | 426 | 144 | 3.26 / 41.73 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.40 | 274 | 696 | 3.95 / 42.43 | 2 | 11 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 32 | 15.38 | 408 | 201 | 0.20 / 34.68 | 2 | 2 |
2 | 12 | 1179.36 | 2 | 15.47 | 1882 | 58 | 0.26 / 34.74 | 2 | 2 |
3 | 7 | 2007.24 | 38 | 15.09 | 2733 | 1567 | 1.83 / 36.30 | 2 | 2 |
4 | 13 | 1466.84 | 22 | 15.14 | 2130 | 709 | 2.54 / 37.01 | 2 | 3 |
5 | 13 | 776.88 | 22 | 15.25 | 1312 | 440 | 2.98 / 37.45 | 2 | 4 |
6 | 13 | 230.00 | 22 | 15.38 | 610 | 206 | 3.18 / 37.66 | 2 | 4 |
7 | 13 | 76.96 | 22 | 15.41 | 387 | 131 | 3.31 / 37.79 | 2 | 3 |
8 | 8 | 0.20 | 165 | 15.41 | 267 | 679 | 3.99 / 38.47 | 2 | 11 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 32 | 15.38 | 393 | 193 | 0.19 / 30.75 | 2 | 2 |
2 | 12 | 1170.24 | 2 | 15.48 | 1852 | 57 | 0.25 / 30.80 | 2 | 2 |
3 | 7 | 2003.60 | 38 | 15.09 | 2717 | 1558 | 1.81 / 32.36 | 2 | 2 |
4 | 13 | 1317.84 | 22 | 15.17 | 1954 | 652 | 2.46 / 33.01 | 2 | 3 |
5 | 13 | 811.24 | 22 | 15.24 | 1359 | 456 | 2.92 / 33.47 | 2 | 4 |
6 | 13 | 163.56 | 22 | 15.40 | 518 | 175 | 3.09 / 33.64 | 2 | 3 |
7 | 13 | 92.52 | 22 | 15.41 | 413 | 140 | 3.23 / 33.78 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.41 | 273 | 694 | 3.93 / 34.48 | 2 | 10 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.24 | 32 | 15.38 | 402 | 198 | 0.20 / 26.80 | 2 | 2 |
2 | 12 | 1191.36 | 2 | 15.47 | 1875 | 58 | 0.26 / 26.86 | 2 | 2 |
3 | 7 | 2005.36 | 38 | 15.09 | 2722 | 1561 | 1.82 / 28.42 | 2 | 2 |
4 | 13 | 1350.88 | 22 | 15.16 | 1998 | 666 | 2.48 / 29.09 | 2 | 3 |
5 | 13 | 830.04 | 22 | 15.24 | 1379 | 462 | 2.95 / 29.55 | 2 | 4 |
6 | 13 | 166.72 | 22 | 15.40 | 522 | 177 | 3.12 / 29.73 | 2 | 3 |
7 | 13 | 89.08 | 22 | 15.41 | 408 | 138 | 3.26 / 29.87 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.40 | 270 | 686 | 3.95 / 30.55 | 2 | 11 |
Average= | 3.39 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 32 | 15.38 | 399 | 196 | 0.20 / 22.83 | 2 | 2 |
2 | 12 | 1160.88 | 2 | 15.50 | 1840 | 57 | 0.25 / 22.89 | 2 | 2 |
3 | 7 | 2001.52 | 38 | 15.09 | 2706 | 1552 | 1.81 / 24.44 | 2 | 2 |
4 | 13 | 1477.76 | 22 | 15.15 | 2141 | 714 | 2.52 / 25.15 | 2 | 3 |
5 | 13 | 761.20 | 22 | 15.26 | 1290 | 433 | 2.95 / 25.59 | 2 | 4 |
6 | 13 | 211.16 | 22 | 15.39 | 591 | 200 | 3.15 / 25.79 | 2 | 3 |
7 | 13 | 77.68 | 22 | 15.42 | 393 | 133 | 3.29 / 25.92 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.41 | 270 | 687 | 3.97 / 26.61 | 2 | 8 |
Average= | 3.33 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 30 | 15.39 | 389 | 180 | 0.18 / 18.84 | 2 | 2 |
2 | 3 | 1064.28 | 2 | 15.39 | 1727 | 53 | 0.23 / 18.89 | 2 | 2 |
3 | 7 | 2003.56 | 38 | 15.10 | 2714 | 1557 | 1.79 / 20.45 | 2 | 2 |
4 | 13 | 1490.28 | 18 | 15.16 | 2159 | 589 | 2.38 / 21.04 | 2 | 3 |
5 | 13 | 951.68 | 18 | 15.23 | 1530 | 419 | 2.80 / 21.45 | 2 | 3 |
6 | 13 | 434.96 | 18 | 15.33 | 890 | 246 | 3.04 / 21.70 | 2 | 4 |
7 | 13 | 139.52 | 18 | 15.41 | 485 | 135 | 3.18 / 21.83 | 2 | 3 |
8 | 13 | 82.04 | 18 | 15.42 | 397 | 110 | 3.29 / 21.95 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.41 | 271 | 689 | 3.98 / 22.63 | 2 | 10 |
Average= | 3.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 28 | 15.39 | 390 | 168 | 0.17 / 14.94 | 2 | 2 |
2 | 10 | 1051.20 | 3 | 15.36 | 1661 | 77 | 0.24 / 15.02 | 2 | 2 |
3 | 7 | 2004.48 | 38 | 15.11 | 2687 | 1543 | 1.79 / 16.56 | 2 | 2 |
4 | 13 | 1481.20 | 18 | 15.17 | 2139 | 584 | 2.37 / 17.14 | 2 | 3 |
5 | 13 | 960.32 | 18 | 15.24 | 1520 | 417 | 2.79 / 17.56 | 2 | 3 |
6 | 13 | 307.48 | 18 | 15.38 | 715 | 198 | 2.99 / 17.76 | 2 | 4 |
7 | 13 | 117.88 | 18 | 15.42 | 437 | 121 | 3.11 / 17.88 | 2 | 3 |
8 | 13 | 74.20 | 18 | 15.43 | 375 | 104 | 3.21 / 17.98 | 2 | 3 |
9 | 8 | 0.16 | 165 | 15.41 | 264 | 671 | 3.88 / 18.66 | 2 | 8 |
Average= | 3.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 30 | 15.39 | 391 | 181 | 0.18 / 11.52 | 2 | 2 |
2 | 3 | 1020.56 | 1 | 15.44 | 1669 | 26 | 0.21 / 11.54 | 2 | 2 |
3 | 7 | 1506.36 | 38 | 15.24 | 2137 | 1238 | 1.44 / 12.78 | 2 | 2 |
4 | 13 | 1362.12 | 18 | 15.24 | 1983 | 544 | 1.99 / 13.33 | 2 | 3 |
5 | 13 | 866.92 | 18 | 15.29 | 1407 | 387 | 2.38 / 13.71 | 2 | 3 |
6 | 13 | 214.44 | 18 | 15.42 | 579 | 161 | 2.54 / 13.87 | 2 | 3 |
7 | 13 | 123.04 | 18 | 15.43 | 445 | 124 | 2.66 / 14.00 | 2 | 3 |
8 | 13 | 64.76 | 18 | 15.44 | 366 | 102 | 2.76 / 14.10 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.42 | 265 | 674 | 3.44 / 14.77 | 2 | 10 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 30 | 15.39 | 396 | 183 | 0.18 / 8.04 | 2 | 2 |
2 | 3 | 1023.72 | 1 | 15.44 | 1672 | 26 | 0.21 / 8.07 | 2 | 2 |
3 | 7 | 1526.16 | 38 | 15.23 | 2164 | 1252 | 1.46 / 9.32 | 2 | 2 |
4 | 13 | 1393.64 | 18 | 15.23 | 2022 | 554 | 2.02 / 9.87 | 2 | 3 |
5 | 13 | 872.68 | 18 | 15.28 | 1417 | 390 | 2.41 / 10.26 | 2 | 3 |
6 | 13 | 212.00 | 18 | 15.41 | 582 | 161 | 2.57 / 10.43 | 2 | 3 |
7 | 13 | 117.36 | 18 | 15.43 | 446 | 124 | 2.69 / 10.55 | 2 | 3 |
8 | 13 | 67.44 | 18 | 15.43 | 374 | 104 | 2.79 / 10.65 | 2 | 3 |
9 | 8 | 0.16 | 165 | 15.42 | 269 | 684 | 3.48 / 11.34 | 2 | 9 |
Average= | 2.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 28 | 15.43 | 392 | 169 | 0.17 / 4.61 | 2 | 2 |
2 | 3 | 1055.84 | 1 | 15.42 | 1697 | 26 | 0.20 / 4.64 | 2 | 2 |
3 | 3 | 1019.32 | 1 | 15.48 | 1670 | 26 | 0.22 / 4.67 | 2 | 2 |
4 | 7 | 1524.28 | 38 | 15.24 | 2164 | 1253 | 1.47 / 5.92 | 2 | 2 |
5 | 13 | 1229.72 | 18 | 15.26 | 1829 | 502 | 1.98 / 6.42 | 2 | 3 |
6 | 13 | 757.36 | 18 | 15.31 | 1277 | 352 | 2.33 / 6.77 | 2 | 3 |
7 | 13 | 248.64 | 18 | 15.40 | 636 | 176 | 2.51 / 6.95 | 2 | 3 |
8 | 13 | 130.12 | 18 | 15.42 | 470 | 130 | 2.64 / 7.08 | 2 | 3 |
9 | 13 | 42.16 | 18 | 15.44 | 338 | 94 | 2.73 / 7.17 | 2 | 3 |
10 | 8 | 0.16 | 165 | 15.42 | 269 | 684 | 3.41 / 7.86 | 2 | 9 |
Average= | 2.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 28 | 15.62 | 346 | 151 | 0.15 / 1.54 | 2 | 2 |
2 | 10 | 1002.32 | 2 | 15.47 | 1597 | 49 | 0.20 / 1.59 | 2 | 2 |
3 | 7 | 1004.28 | 74 | 15.32 | 1537 | 1742 | 1.94 / 3.34 | 2 | 3 |
4 | 13 | 59.44 | 18 | 15.51 | 367 | 102 | 2.05 / 3.44 | 2 | 3 |
5 | 8 | 0.12 | 240 | 15.47 | 271 | 1006 | 3.05 / 4.44 | 2 | 12 |
Average= | 2.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 22 | 15.78 | 351 | 122 | 0.12 / 0.12 | 2 | 2 |
2 | 7 | 126.16 | 74 | 15.75 | 365 | 425 | 0.55 / 0.55 | 2 | 2 |
3 | 13 | 78.92 | 18 | 15.73 | 301 | 85 | 0.63 / 0.63 | 2 | 2 |
4 | 8 | 0.20 | 240 | 15.69 | 202 | 761 | 1.39 / 1.39 | 2 | 8 |
Average= | 1.39 (KJ/cycle) |