SIO Argo Site:
Pump Diagnostics Page   



Serial= 8692 WMO= 5905707

Return

←PreviousNext→

Cycle 233 GMT 8/12/2024 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 32 14.92 439 210 0.21 / 975.90 2 2
2 12 1189.20 2 15.06 2034 61 0.27 / 975.96 2 2
3 7 2010.32 30 14.65 3017 1326 1.60 / 977.29 2 3
4 13 1540.24 25 14.63 2443 894 2.49 / 978.18 2 7
5 13 864.28 25 14.73 1544 569 3.06 / 978.75 2 4
6 13 176.84 25 14.94 565 211 3.27 / 978.96 2 4
7 13 49.44 25 14.98 366 137 3.41 / 979.10 2 4
8 8 0.08 165 14.96 285 703 4.11 / 979.80 2 9
Average= 4.19
(KJ/cycle)

Cycle 232 GMT 29/11/2024 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 32 14.94 431 206 0.21 / 971.63 2 2
2 12 1175.80 2 15.06 2022 61 0.27 / 971.69 2 2
3 7 2005.92 30 14.67 3011 1325 1.59 / 973.02 2 3
4 13 1695.60 25 14.61 2629 960 2.55 / 973.98 2 4
5 13 839.48 25 14.74 1505 555 3.11 / 974.53 2 5
6 13 289.84 25 14.89 743 277 3.38 / 974.81 2 4
7 13 55.04 25 14.97 390 146 3.53 / 974.95 2 5
8 8 0.04 165 14.94 298 735 4.26 / 975.69 2 10
Average= 4.19
(KJ/cycle)

Cycle 231 GMT 19/11/2024 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 32 14.93 437 209 0.21 / 967.45 2 2
2 12 1175.24 2 15.07 2048 62 0.27 / 967.51 2 3
3 7 2009.16 31 14.66 3019 1372 1.64 / 968.89 3 3
4 13 1687.04 25 14.62 2618 957 2.60 / 969.84 2 6
5 13 816.08 25 14.75 1472 543 3.14 / 970.39 2 4
6 13 164.40 25 14.95 540 202 3.34 / 970.59 2 4
7 13 45.64 25 14.98 358 134 3.48 / 970.72 2 4
8 8 0.00 165 14.96 285 703 4.18 / 971.42 2 8
Average= 4.19
(KJ/cycle)

Cycle 230 GMT 9/11/2024 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 32 14.93 435 208 0.21 / 963.15 2 2
2 12 1172.88 2 15.06 2044 62 0.27 / 963.21 2 2
3 7 2009.60 30 14.67 3018 1328 1.60 / 964.54 2 3
4 13 1698.56 25 14.62 2637 964 2.56 / 965.50 2 5
5 13 985.52 25 14.70 1710 628 3.19 / 966.13 2 4
6 13 245.76 25 14.91 678 253 3.44 / 966.39 2 4
7 13 56.20 25 14.97 384 144 3.59 / 966.53 2 4
8 8 0.08 165 14.96 289 713 4.30 / 967.24 2 12
Average= 4.19
(KJ/cycle)

Cycle 229 GMT 30/10/2024 7:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 32 14.92 439 210 0.21 / 958.88 2 2
2 12 1172.32 2 15.07 2032 61 0.27 / 958.94 2 2
3 7 2010.44 30 14.67 3003 1322 1.59 / 960.26 2 4
4 13 1689.36 25 14.62 2625 959 2.55 / 961.22 2 5
5 13 965.16 25 14.71 1683 619 3.17 / 961.84 2 5
6 13 233.80 25 14.92 662 247 3.42 / 962.09 2 5
7 13 48.04 25 14.98 368 138 3.56 / 962.23 2 4
8 8 0.08 165 14.95 290 715 4.27 / 962.94 2 8
Average= 4.19
(KJ/cycle)

Cycle 228 GMT 20/10/2024 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 32 14.93 438 209 0.21 / 954.60 2 2
2 12 1177.48 2 15.06 2056 62 0.27 / 954.66 2 2
3 7 2010.96 30 14.66 3020 1328 1.60 / 955.99 2 3
4 13 1692.92 25 14.61 2628 960 2.56 / 956.95 2 4
5 13 964.36 25 14.71 1680 618 3.18 / 957.57 2 5
6 13 228.88 25 14.92 645 241 3.42 / 957.81 2 5
7 13 43.12 25 14.97 366 137 3.55 / 957.95 2 4
8 8 0.00 165 14.95 294 725 4.28 / 958.67 2 9
Average= 4.19
(KJ/cycle)

Cycle 227 GMT 10/10/2024 12:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 32 14.92 443 212 0.21 / 950.32 2 2
2 12 1173.80 2 15.07 2002 60 0.27 / 950.38 2 2
3 7 2011.08 30 14.67 3021 1330 1.60 / 951.71 2 3
4 13 1693.60 25 14.62 2634 963 2.56 / 952.67 2 4
5 13 970.48 25 14.71 1687 620 3.18 / 953.29 2 5
6 13 232.16 25 14.92 650 242 3.43 / 953.54 2 4
7 13 53.68 25 14.97 377 141 3.57 / 953.68 2 4
8 8 0.16 165 14.95 290 715 4.28 / 954.39 2 9
Average= 4.19
(KJ/cycle)

Cycle 226 GMT 30/ 9/2024 14:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 32 14.93 437 209 0.21 / 946.00 2 2
2 12 1160.36 2 15.08 1999 60 0.27 / 946.06 2 2
3 7 2012.60 31 14.66 3004 1365 1.63 / 947.43 2 3
4 13 1709.24 25 14.61 2645 966 2.60 / 948.39 2 4
5 13 846.00 25 14.73 1527 562 3.16 / 948.95 2 5
6 13 288.36 25 14.89 747 278 3.44 / 949.23 2 5
7 13 58.84 25 14.97 387 145 3.59 / 949.38 2 5
8 8 -0.04 165 14.95 297 733 4.32 / 950.11 2 10
Average= 4.19
(KJ/cycle)

Cycle 225 GMT 20/ 9/2024 16:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 32 14.93 440 210 0.21 / 941.73 2 2
2 12 1165.48 2 15.09 2012 61 0.27 / 941.79 2 3
3 7 2007.92 30 14.68 3003 1323 1.59 / 943.11 3 4
4 13 1691.16 25 14.62 2623 959 2.55 / 944.07 2 4
5 13 972.40 25 14.71 1690 621 3.17 / 944.69 2 5
6 13 243.24 25 14.92 666 248 3.42 / 944.94 2 5
7 13 48.20 25 14.97 367 137 3.56 / 945.08 2 4
8 8 0.04 165 14.95 290 715 4.27 / 945.79 2 10
Average= 4.18
(KJ/cycle)

Cycle 224 GMT 10/ 9/2024 19: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 32 14.92 443 212 0.21 / 937.45 2 2
2 12 1186.32 2 15.08 2039 61 0.27 / 937.51 2 3
3 7 2003.64 31 14.66 3018 1372 1.64 / 938.88 3 4
4 13 1681.44 25 14.62 2616 956 2.60 / 939.83 2 5
5 13 827.96 25 14.75 1493 551 3.15 / 940.39 2 4
6 13 269.08 25 14.91 711 265 3.42 / 940.65 2 4
7 13 50.48 25 14.97 376 141 3.56 / 940.79 2 5
8 8 0.04 165 14.95 294 725 4.28 / 941.52 2 9
Average= 4.18
(KJ/cycle)

Cycle 223 GMT 31/ 8/2024 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 32 14.93 446 213 0.21 / 933.13 2 2
2 12 1181.48 2 15.08 2029 61 0.27 / 933.19 2 2
3 7 2011.76 31 14.66 3006 1366 1.64 / 934.56 2 3
4 13 1710.24 25 14.61 2655 970 2.61 / 935.53 2 3
5 13 840.68 25 14.74 1514 558 3.17 / 936.08 2 5
6 13 289.92 25 14.89 740 275 3.44 / 936.36 2 4
7 13 54.16 25 14.96 387 145 3.59 / 936.50 2 5
8 8 0.08 165 14.94 296 730 4.32 / 937.23 2 8
Average= 4.18
(KJ/cycle)

Cycle 222 GMT 21/ 8/2024 23:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 32 14.93 444 212 0.21 / 928.83 2 2
2 12 1160.00 2 15.09 1998 60 0.27 / 928.89 2 3
3 7 2011.92 30 14.67 3007 1323 1.60 / 930.21 3 3
4 13 1692.40 25 14.63 2629 962 2.56 / 931.17 2 4
5 13 982.64 25 14.70 1704 626 3.18 / 931.80 2 4
6 13 254.60 25 14.91 687 256 3.44 / 932.05 2 5
7 13 55.24 25 14.97 382 143 3.58 / 932.20 2 4
8 8 0.36 165 14.95 292 720 4.30 / 932.92 2 8
Average= 4.18
(KJ/cycle)

Cycle 221 GMT 12/ 8/2024 2: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 32 14.93 434 207 0.21 / 924.57 2 2
2 12 1164.08 2 15.08 1996 60 0.27 / 924.63 2 2
3 7 2008.28 30 14.66 3002 1320 1.59 / 925.95 2 3
4 13 1682.00 25 14.62 2614 955 2.54 / 926.91 2 3
5 13 951.96 25 14.71 1661 611 3.15 / 927.52 2 5
6 13 230.84 25 14.92 649 242 3.40 / 927.76 2 4
7 13 55.60 25 14.97 376 141 3.54 / 927.90 2 4
8 8 0.04 165 14.95 288 710 4.25 / 928.61 2 8
Average= 4.18
(KJ/cycle)

Cycle 220 GMT 2/ 8/2024 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 32 14.94 445 213 0.21 / 920.47 2 2
2 12 1178.72 2 15.08 2041 62 0.27 / 920.53 2 2
3 7 2005.16 30 14.68 3006 1324 1.60 / 921.85 2 4
4 13 1548.92 25 14.64 2443 894 2.49 / 922.75 2 3
5 13 865.56 25 14.73 1546 569 3.06 / 923.31 2 5
6 13 183.60 25 14.94 570 213 3.27 / 923.53 2 4
7 13 48.24 25 14.97 362 135 3.41 / 923.66 2 4
8 8 0.04 165 14.95 285 703 4.11 / 924.37 2 10
Average= 4.18
(KJ/cycle)

Cycle 219 GMT 23/ 7/2024 6:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 32 14.93 442 211 0.21 / 916.18 2 2
2 12 1171.00 2 15.08 2033 61 0.27 / 916.25 2 2
3 7 2009.12 30 14.68 3005 1323 1.60 / 917.57 2 3
4 13 1691.84 25 14.63 2618 958 2.55 / 918.53 2 4
5 13 972.32 25 14.71 1679 617 3.17 / 919.14 2 5
6 13 244.60 25 14.92 669 250 3.42 / 919.39 2 4
7 13 59.12 25 14.97 377 141 3.56 / 919.53 2 4
8 8 0.00 165 14.96 291 718 4.28 / 920.25 2 9
Average= 4.18
(KJ/cycle)

Cycle 218 GMT 13/ 7/2024 8:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 32 14.93 448 214 0.21 / 911.94 2 2
2 12 1169.24 2 15.08 2036 61 0.28 / 912.01 2 2
3 7 2004.56 30 14.68 2994 1319 1.59 / 913.32 2 3
4 13 1672.96 25 14.64 2602 952 2.55 / 914.28 2 4
5 13 944.88 25 14.72 1651 608 3.15 / 914.88 2 6
6 13 226.40 25 14.92 637 238 3.39 / 915.12 2 4
7 13 53.52 25 14.97 370 138 3.53 / 915.26 2 4
8 8 0.16 165 14.95 289 713 4.24 / 915.97 2 10
Average= 4.18
(KJ/cycle)

Cycle 217 GMT 3/ 7/2024 11:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 32 14.93 429 205 0.20 / 907.72 2 2
2 12 1174.48 2 15.09 2031 61 0.27 / 907.78 2 3
3 7 2010.20 30 14.66 3023 1330 1.60 / 909.11 3 4
4 13 1690.00 25 14.63 2621 959 2.55 / 910.07 2 3
5 13 796.28 25 14.76 1447 534 3.09 / 910.60 2 5
6 13 250.68 25 14.91 689 257 3.35 / 910.86 2 5
7 13 56.36 25 14.97 391 146 3.49 / 911.00 2 4
8 8 0.04 165 14.95 294 725 4.22 / 911.73 2 11
Average= 4.18
(KJ/cycle)

Cycle 216 GMT 23/ 6/2024 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 32 14.93 438 209 0.21 / 903.50 2 2
2 12 1177.08 2 15.08 2017 61 0.27 / 903.56 2 2
3 7 2008.80 30 14.67 3006 1323 1.59 / 904.89 2 3
4 13 1694.32 25 14.63 2623 959 2.55 / 905.85 2 4
5 13 816.44 25 14.75 1476 544 3.10 / 906.39 2 4
6 13 272.88 25 14.90 715 266 3.36 / 906.66 2 5
7 13 54.20 25 14.97 376 141 3.50 / 906.80 2 5
8 8 0.08 165 14.95 290 715 4.22 / 907.51 2 11
Average= 4.18
(KJ/cycle)

Cycle 215 GMT 13/ 6/2024 15:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 32 14.94 438 209 0.21 / 899.25 2 2
2 12 1163.76 2 15.10 2001 60 0.27 / 899.31 2 3
3 7 2007.84 30 14.68 2994 1319 1.59 / 900.62 3 3
4 13 1687.32 25 14.63 2616 957 2.55 / 901.58 2 3
5 13 959.08 25 14.72 1674 616 3.16 / 902.20 2 5
6 13 240.36 25 14.92 664 248 3.41 / 902.45 2 4
7 13 60.80 25 14.97 383 143 3.55 / 902.59 2 4
8 8 0.16 165 14.95 286 705 4.26 / 903.29 2 10
Average= 4.18
(KJ/cycle)

Cycle 214 GMT 3/ 6/2024 17:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 32 14.93 442 211 0.21 / 895.12 2 2
2 12 1169.92 2 15.08 2015 61 0.27 / 895.18 2 2
3 7 2003.24 30 14.66 3004 1321 1.59 / 896.50 2 3
4 13 1668.80 25 14.63 2605 953 2.55 / 897.45 2 4
5 13 810.72 25 14.76 1471 543 3.09 / 898.00 2 4
6 13 168.92 25 14.95 546 204 3.29 / 898.20 2 4
7 13 55.00 25 14.98 371 139 3.43 / 898.34 2 4
8 8 0.04 165 14.96 283 699 4.13 / 899.04 2 8
Average= 4.18
(KJ/cycle)

Cycle 213 GMT 24/ 5/2024 20: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 32 14.94 434 207 0.21 / 890.85 2 2
2 12 1166.16 2 15.08 1996 60 0.27 / 890.91 2 2
3 7 2009.64 30 14.67 3011 1325 1.59 / 892.24 2 3
4 13 1543.60 25 14.65 2447 896 2.49 / 893.13 2 3
5 13 1022.76 25 14.69 1757 645 3.13 / 893.78 2 4
6 13 263.00 25 14.90 700 261 3.40 / 894.04 2 4
7 13 60.08 25 14.96 391 146 3.54 / 894.19 2 5
8 8 0.12 165 14.95 292 720 4.26 / 894.91 2 11
Average= 4.18
(KJ/cycle)

Cycle 212 GMT 14/ 5/2024 22:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 32 14.93 432 206 0.21 / 886.60 2 2
2 12 1181.04 2 15.08 2039 61 0.27 / 886.66 2 2
3 7 2010.40 30 14.67 3017 1328 1.60 / 887.99 2 4
4 13 1692.60 25 14.63 2619 958 2.55 / 888.95 2 4
5 13 954.36 25 14.71 1666 613 3.17 / 889.56 2 6
6 13 224.76 25 14.92 635 237 3.40 / 889.80 2 4
7 13 55.12 25 14.97 378 141 3.54 / 889.94 2 4
8 8 0.12 165 14.95 286 705 4.25 / 890.64 2 12
Average= 4.18
(KJ/cycle)

Cycle 211 GMT 5/ 5/2024 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 32 14.93 441 211 0.21 / 882.34 2 2
2 12 1172.80 2 15.08 2002 60 0.27 / 882.40 2 2
3 7 2002.36 30 14.68 3004 1323 1.59 / 883.72 2 3
4 13 1693.68 25 14.63 2621 959 2.55 / 884.68 2 5
5 13 979.60 25 14.71 1689 621 3.17 / 885.30 2 6
6 13 256.12 25 14.91 680 253 3.43 / 885.55 2 4
7 13 63.36 25 14.97 386 144 3.57 / 885.70 2 4
8 8 0.04 165 14.96 283 699 4.27 / 886.39 2 9
Average= 4.18
(KJ/cycle)

Cycle 210 GMT 25/ 4/2024 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 32 14.93 433 207 0.21 / 878.06 2 2
2 12 1177.16 2 15.08 2020 61 0.27 / 878.12 2 2
3 7 2004.44 30 14.68 3001 1322 1.59 / 879.44 2 3
4 13 1702.36 25 14.63 2640 966 2.56 / 880.40 2 5
5 13 974.76 25 14.71 1691 622 3.18 / 881.03 2 6
6 13 244.24 25 14.91 676 252 3.43 / 881.28 2 5
7 13 60.52 25 14.97 383 143 3.57 / 881.42 2 4
8 8 0.08 165 14.95 285 703 4.28 / 882.12 2 9
Average= 4.18
(KJ/cycle)

Cycle 209 GMT 15/ 4/2024 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 32 14.94 437 209 0.21 / 873.97 2 2
2 12 1172.08 2 15.07 2018 61 0.27 / 874.03 2 2
3 7 2005.68 30 14.67 3001 1321 1.59 / 875.35 2 4
4 13 1553.76 25 14.65 2447 896 2.49 / 876.25 2 4
5 13 866.44 25 14.74 1544 569 3.06 / 876.82 2 4
6 13 180.08 25 14.94 562 210 3.27 / 877.03 2 4
7 13 49.00 25 14.97 359 134 3.40 / 877.16 2 4
8 8 0.12 165 14.95 278 686 4.09 / 877.85 2 11
Average= 4.18
(KJ/cycle)

Cycle 208 GMT 5/ 4/2024 7:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 32 14.93 430 205 0.21 / 869.73 2 2
2 12 1163.72 2 15.10 1995 60 0.27 / 869.79 2 2
3 7 2010.68 30 14.69 3006 1325 1.59 / 871.11 2 4
4 13 1694.28 25 14.63 2635 964 2.55 / 872.08 2 5
5 13 958.96 25 14.72 1667 613 3.17 / 872.69 2 5
6 13 239.08 25 14.92 655 244 3.41 / 872.93 2 4
7 13 58.32 25 14.97 372 139 3.55 / 873.07 2 4
8 8 -0.08 165 14.96 280 691 4.24 / 873.76 2 10
Average= 4.18
(KJ/cycle)

Cycle 207 GMT 26/ 3/2024 9:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 32 14.93 439 210 0.21 / 865.49 2 2
2 12 1185.60 2 15.08 2029 61 0.27 / 865.55 2 2
3 7 2008.48 30 14.67 3020 1329 1.60 / 866.88 2 4
4 13 1692.28 25 14.63 2638 965 2.56 / 867.85 2 4
5 13 821.64 25 14.75 1489 549 3.11 / 868.40 2 5
6 13 278.48 25 14.90 723 269 3.38 / 868.66 2 5
7 13 60.24 25 14.96 390 146 3.53 / 868.81 2 5
8 8 0.24 165 14.95 288 710 4.24 / 869.52 2 13
Average= 4.18
(KJ/cycle)

Cycle 206 GMT 16/ 3/2024 11:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 32 14.93 441 211 0.21 / 861.39 2 2
2 12 1172.16 2 15.08 2024 61 0.27 / 861.45 2 2
3 7 2005.68 30 14.68 3004 1323 1.59 / 862.78 2 3
4 13 1545.56 25 14.66 2432 891 2.49 / 863.67 2 3
5 13 860.20 25 14.74 1538 567 3.05 / 864.23 2 5
6 13 181.16 25 14.94 564 211 3.26 / 864.45 2 4
7 13 42.80 25 14.98 356 133 3.40 / 864.58 2 4
8 8 0.16 165 14.95 285 703 4.10 / 865.28 2 10
Average= 4.18
(KJ/cycle)

Cycle 205 GMT 6/ 3/2024 13:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 32 14.93 438 209 0.21 / 857.29 2 2
2 12 1178.12 2 15.09 2022 61 0.27 / 857.35 2 2
3 7 2009.32 30 14.67 3010 1325 1.59 / 858.68 2 3
4 13 1543.48 25 14.65 2433 891 2.49 / 859.57 2 4
5 13 860.04 25 14.74 1541 568 3.05 / 860.14 2 4
6 13 178.48 25 14.94 562 210 3.26 / 860.35 2 4
7 13 42.32 25 14.98 355 133 3.40 / 860.48 2 4
8 8 0.08 165 14.95 285 703 4.10 / 861.18 2 10
Average= 4.18
(KJ/cycle)

Cycle 204 GMT 25/ 2/2024 16: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 32 14.93 433 207 0.21 / 853.04 2 2
2 12 1177.68 2 15.08 2025 61 0.27 / 853.10 2 2
3 7 2002.88 30 14.68 2995 1319 1.59 / 854.42 2 3
4 13 1692.44 25 14.63 2631 962 2.55 / 855.38 2 4
5 13 949.04 25 14.72 1663 612 3.16 / 855.99 2 5
6 13 223.92 25 14.92 643 240 3.40 / 856.23 2 5
7 13 45.44 25 14.98 363 136 3.54 / 856.37 2 5
8 8 0.00 165 14.95 289 713 4.25 / 857.08 2 10
Average= 4.18
(KJ/cycle)

Cycle 203 GMT 15/ 2/2024 18:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 32 14.93 436 208 0.21 / 848.76 2 2
2 12 1170.16 2 15.09 2021 61 0.27 / 848.82 2 2
3 7 2003.44 30 14.68 3008 1325 1.59 / 850.15 2 3
4 13 1687.96 25 14.64 2626 961 2.56 / 851.11 2 4
5 13 972.12 25 14.71 1693 623 3.18 / 851.73 2 5
6 13 237.72 25 14.92 667 249 3.43 / 851.98 2 4
7 13 45.16 25 14.97 365 137 3.56 / 852.12 2 4
8 8 0.00 165 14.95 290 715 4.28 / 852.83 2 7
Average= 4.18
(KJ/cycle)

Cycle 202 GMT 5/ 2/2024 20:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 32 14.93 436 208 0.21 / 844.55 2 2
2 12 1180.68 2 15.08 2025 61 0.27 / 844.61 2 2
3 7 2010.16 30 14.68 3004 1323 1.59 / 845.94 2 3
4 13 1538.72 25 14.66 2438 894 2.49 / 846.83 2 3
5 13 993.08 25 14.71 1718 632 3.12 / 847.46 2 4
6 13 244.28 25 14.92 681 254 3.37 / 847.71 2 5
7 13 30.88 25 14.98 344 129 3.50 / 847.84 2 4
8 8 0.08 165 14.95 288 710 4.21 / 848.55 2 13
Average= 4.18
(KJ/cycle)

Cycle 201 GMT 26/ 1/2024 22:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 32 14.92 430 205 0.21 / 840.27 2 2
2 12 1174.88 2 15.08 2018 61 0.27 / 840.33 2 2
3 7 2004.00 30 14.68 3005 1323 1.59 / 841.65 2 4
4 13 1682.20 25 14.64 2630 963 2.55 / 842.62 2 5
5 13 955.52 25 14.72 1673 616 3.17 / 843.23 2 5
6 13 225.24 25 14.92 648 242 3.41 / 843.47 2 5
7 13 47.12 25 14.97 376 141 3.55 / 843.62 2 4
8 8 0.12 165 14.95 295 728 4.28 / 844.34 2 12
Average= 4.18
(KJ/cycle)

Cycle 200 GMT 17/ 1/2024 1:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 32 14.92 436 208 0.21 / 836.05 2 2
2 12 1166.52 2 15.09 2008 61 0.27 / 836.11 2 2
3 7 2009.24 30 14.67 3015 1327 1.60 / 837.44 2 3
4 13 1684.64 25 14.64 2625 961 2.56 / 838.40 2 4
5 13 814.04 25 14.76 1479 546 3.10 / 838.95 2 4
6 13 262.60 25 14.91 709 264 3.37 / 839.21 2 5
7 13 25.04 25 14.98 344 129 3.50 / 839.34 2 5
8 8 0.04 165 14.95 294 725 4.22 / 840.06 2 9
Average= 4.18
(KJ/cycle)

Cycle 199 GMT 7/ 1/2024 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 32 14.93 435 208 0.21 / 831.74 2 2
2 12 1168.40 2 15.09 2002 60 0.27 / 831.80 2 2
3 7 2008.52 31 14.68 3013 1371 1.64 / 833.17 2 4
4 13 1681.48 25 14.64 2615 957 2.60 / 834.13 2 4
5 13 955.60 25 14.72 1666 613 3.21 / 834.74 2 4
6 13 225.80 25 14.92 649 242 3.45 / 834.99 2 4
7 13 39.04 25 14.97 361 135 3.59 / 835.12 2 4
8 8 0.16 165 14.95 293 723 4.31 / 835.84 2 12
Average= 4.18
(KJ/cycle)

Cycle 198 GMT 28/12/2023 5:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 32 14.92 417 199 0.20 / 827.58 2 2
2 12 1166.40 2 15.10 2022 61 0.26 / 827.64 2 2
3 7 2007.84 30 14.68 3021 1330 1.59 / 828.97 2 3
4 13 1687.32 25 14.64 2628 962 2.55 / 829.94 2 6
5 13 830.24 25 14.76 1494 551 3.10 / 830.49 2 4
6 13 160.64 25 14.95 542 203 3.31 / 830.69 2 4
7 13 32.76 25 14.98 344 129 3.44 / 830.82 2 5
8 8 0.16 165 14.95 290 715 4.15 / 831.53 2 11
Average= 4.18
(KJ/cycle)

Cycle 197 GMT 18/12/2023 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 32 14.92 429 205 0.20 / 823.48 2 2
2 12 1178.68 2 15.08 2025 61 0.27 / 823.54 2 2
3 7 2003.48 30 14.69 3001 1323 1.59 / 824.86 2 3
4 13 1555.44 25 14.66 2457 900 2.49 / 825.76 2 3
5 13 865.96 25 14.74 1547 570 3.06 / 826.33 2 5
6 13 175.40 25 14.94 561 210 3.27 / 826.54 2 4
7 13 34.96 25 14.97 348 130 3.40 / 826.67 2 4
8 8 0.04 165 14.95 288 710 4.11 / 827.38 2 9
Average= 4.18
(KJ/cycle)

Cycle 196 GMT 8/12/2023 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 14.93 420 201 0.20 / 819.19 2 2
2 12 1187.36 2 15.09 2042 62 0.26 / 819.25 2 2
3 7 2007.04 30 14.70 3001 1323 1.59 / 820.57 2 3
4 13 1691.28 25 14.64 2627 961 2.55 / 821.53 2 5
5 13 980.92 25 14.72 1700 626 3.17 / 822.16 2 5
6 13 247.48 25 14.91 675 252 3.42 / 822.41 2 5
7 13 45.08 25 14.97 370 138 3.56 / 822.55 2 4
8 8 0.12 165 14.95 295 728 4.29 / 823.28 2 11
Average= 4.18
(KJ/cycle)

Cycle 195 GMT 28/11/2023 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 32 14.92 425 203 0.20 / 814.87 2 2
2 12 1166.08 2 15.09 2016 61 0.26 / 814.93 2 2
3 7 2010.88 31 14.68 3015 1372 1.64 / 816.31 2 3
4 13 1690.20 25 14.64 2627 961 2.60 / 817.27 2 4
5 13 968.76 25 14.71 1692 622 3.22 / 817.89 2 5
6 13 230.60 25 14.92 650 242 3.46 / 818.13 2 5
7 13 40.88 25 14.97 357 134 3.60 / 818.27 2 5
8 8 0.04 165 14.95 291 718 4.31 / 818.98 2 12
Average= 4.18
(KJ/cycle)

Cycle 194 GMT 18/11/2023 13:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 32 14.95 416 199 0.20 / 810.68 2 2
2 12 1185.04 2 15.09 2074 63 0.26 / 810.74 2 2
3 7 2007.68 30 14.68 3021 1330 1.59 / 812.07 2 3
4 13 1536.52 25 14.67 2436 893 2.49 / 812.97 2 4
5 13 853.24 25 14.74 1534 565 3.05 / 813.53 2 5
6 13 288.52 25 14.88 745 277 3.33 / 813.81 2 5
7 13 27.44 25 14.96 346 129 3.46 / 813.94 2 4
8 8 0.16 165 14.93 297 732 4.19 / 814.67 2 8
Average= 4.18
(KJ/cycle)

Cycle 193 GMT 8/11/2023 15:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 32 14.94 426 204 0.20 / 806.41 2 2
2 12 1160.56 2 15.10 2024 61 0.26 / 806.48 2 2
3 7 2003.36 31 14.68 3007 1368 1.63 / 807.84 2 3
4 13 1684.40 25 14.64 2622 960 2.59 / 808.80 2 4
5 13 945.56 25 14.73 1663 612 3.21 / 809.42 2 4
6 13 212.16 25 14.93 623 233 3.44 / 809.65 2 4
7 13 22.28 25 14.98 327 122 3.56 / 809.77 2 4
8 8 -0.08 165 14.96 288 711 4.27 / 810.48 2 10
Average= 4.18
(KJ/cycle)

Cycle 192 GMT 29/10/2023 17:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 32 14.93 437 209 0.21 / 802.24 2 2
2 12 1171.72 2 15.09 2038 62 0.27 / 802.31 2 2
3 7 2010.08 31 14.68 3008 1369 1.64 / 803.67 2 3
4 13 1694.20 25 14.64 2637 965 2.60 / 804.64 2 6
5 13 813.64 25 14.76 1485 548 3.15 / 805.19 2 4
6 13 168.36 25 14.95 541 202 3.35 / 805.39 2 4
7 13 18.28 25 14.99 314 118 3.47 / 805.51 2 4
8 8 0.12 165 14.96 285 703 4.18 / 806.21 2 10
Average= 4.18
(KJ/cycle)

Cycle 191 GMT 19/10/2023 20: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 32 14.94 423 202 0.20 / 797.92 2 2
2 12 1166.40 2 15.11 2002 61 0.26 / 797.98 2 3
3 7 2005.40 30 14.69 2999 1322 1.58 / 799.30 3 3
4 13 1850.40 25 14.62 2831 1035 2.62 / 800.34 2 3
5 13 939.24 25 14.73 1652 608 3.23 / 800.95 2 5
6 13 221.52 25 14.93 634 237 3.46 / 801.18 2 4
7 13 44.00 25 14.98 362 136 3.60 / 801.32 2 4
8 8 0.00 165 14.95 290 715 4.32 / 802.04 2 9
Average= 4.18
(KJ/cycle)

Cycle 190 GMT 9/10/2023 22:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 32 14.93 435 208 0.21 / 793.81 2 2
2 12 1174.24 2 15.10 2038 62 0.27 / 793.87 2 2
3 7 2010.68 30 14.69 3020 1331 1.60 / 795.20 2 3
4 13 1551.68 25 14.67 2458 901 2.50 / 796.10 2 3
5 13 874.12 25 14.75 1562 576 3.08 / 796.68 2 5
6 13 193.04 25 14.94 588 220 3.30 / 796.89 2 4
7 13 20.32 25 14.99 319 120 3.42 / 797.01 2 4
8 8 0.20 165 14.96 286 706 4.12 / 797.72 2 12
Average= 4.18
(KJ/cycle)

Cycle 189 GMT 30/ 9/2023 0:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 32 14.95 438 210 0.21 / 789.53 2 2
2 12 1174.64 2 15.10 2052 62 0.27 / 789.59 2 2
3 7 2008.00 30 14.69 3027 1334 1.61 / 790.92 2 3
4 13 1550.00 25 14.67 2459 902 2.51 / 791.82 2 4
5 13 1005.60 25 14.71 1732 637 3.14 / 792.46 2 4
6 13 266.60 25 14.91 708 264 3.41 / 792.73 2 5
7 13 54.44 25 14.97 386 144 3.55 / 792.87 2 4
8 8 0.04 165 14.95 295 728 4.28 / 793.60 2 9
Average= 4.18
(KJ/cycle)

Cycle 188 GMT 20/ 9/2023 2:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 32 14.93 441 211 0.21 / 785.44 2 2
2 12 1173.08 2 15.10 2032 61 0.27 / 785.50 2 2
3 7 2008.00 30 14.69 3020 1331 1.60 / 786.83 2 3
4 13 1534.12 25 14.67 2431 892 2.49 / 787.72 2 4
5 13 848.64 25 14.75 1528 563 3.06 / 788.28 2 5
6 13 176.72 25 14.95 560 209 3.27 / 788.49 2 4
7 13 20.76 25 14.99 322 121 3.39 / 788.61 2 4
8 8 -0.04 165 14.96 285 703 4.09 / 789.32 2 8
Average= 4.18
(KJ/cycle)

Cycle 187 GMT 10/ 9/2023 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 32 14.94 430 206 0.21 / 781.36 2 2
2 12 1167.64 2 15.10 2042 62 0.27 / 781.42 2 2
3 7 2003.96 30 14.68 3015 1328 1.60 / 782.75 2 4
4 13 1688.12 25 14.64 2628 962 2.56 / 783.71 2 4
5 13 811.88 25 14.76 1477 545 3.10 / 784.25 2 4
6 13 264.32 25 14.91 701 261 3.36 / 784.51 2 4
7 8 0.04 165 14.96 288 711 4.07 / 785.23 2 9
Average= 4.18
(KJ/cycle)

Cycle 186 GMT 31/ 8/2023 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 32 14.93 451 215 0.22 / 777.27 2 2
2 12 1174.20 2 15.11 2015 61 0.28 / 777.33 2 3
3 7 2010.44 30 14.69 3012 1327 1.60 / 778.66 3 3
4 13 1548.84 25 14.67 2464 904 2.51 / 779.56 2 4
5 13 850.64 25 14.75 1532 565 3.07 / 780.13 2 4
6 13 177.52 25 14.95 560 209 3.28 / 780.34 2 3
7 13 19.84 25 14.99 315 118 3.40 / 780.45 2 4
8 8 0.04 165 14.96 283 699 4.10 / 781.15 2 7
Average= 4.18
(KJ/cycle)

Cycle 185 GMT 21/ 8/2023 8:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 32 14.93 441 211 0.21 / 773.03 2 2
2 12 1181.16 2 15.11 2029 61 0.27 / 773.09 2 2
3 7 2009.96 30 14.69 3008 1326 1.60 / 774.41 2 3
4 13 1535.16 25 14.67 2431 892 2.49 / 775.31 2 5
5 13 1007.88 25 14.71 1738 639 3.13 / 775.95 2 5
6 13 260.48 25 14.91 697 260 3.39 / 776.20 2 5
7 13 49.16 25 14.97 369 138 3.53 / 776.34 2 4
8 8 0.12 165 14.95 288 710 4.24 / 777.05 2 9
Average= 4.18
(KJ/cycle)

Cycle 184 GMT 11/ 8/2023 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 32 14.93 443 212 0.21 / 768.70 2 2
2 12 1179.68 2 15.11 2039 62 0.27 / 768.76 2 3
3 7 2005.20 30 14.70 3004 1325 1.60 / 770.08 3 3
4 13 1850.32 25 14.63 2829 1035 2.63 / 771.12 2 4
5 13 930.04 25 14.75 1637 604 3.24 / 771.72 2 5
6 13 222.76 25 14.94 637 238 3.47 / 771.96 2 4
7 13 52.44 25 14.99 372 139 3.61 / 772.10 2 4
8 8 0.08 165 14.96 291 718 4.33 / 772.82 2 9
Average= 4.18
(KJ/cycle)

Cycle 183 GMT 1/ 8/2023 13:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 32 14.93 438 209 0.21 / 764.46 2 2
2 12 1179.28 2 15.09 2055 62 0.27 / 764.52 2 2
3 7 2011.56 30 14.69 3024 1333 1.60 / 765.86 2 3
4 13 1693.92 25 14.65 2637 966 2.57 / 766.82 2 4
5 13 798.96 25 14.77 1464 541 3.11 / 767.36 2 6
6 13 256.40 25 14.92 693 258 3.37 / 767.62 2 4
7 13 45.04 25 14.98 371 139 3.51 / 767.76 2 4
8 8 0.12 165 14.95 294 725 4.23 / 768.48 2 9
Average= 4.18
(KJ/cycle)

Cycle 182 GMT 22/ 7/2023 15:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 32 14.93 424 203 0.20 / 760.22 2 2
2 12 1174.12 2 15.10 2039 62 0.26 / 760.28 2 2
3 7 2003.56 30 14.70 3014 1329 1.59 / 761.61 2 3
4 13 1674.64 25 14.66 2609 956 2.55 / 762.56 2 6
5 13 949.08 25 14.74 1668 615 3.16 / 763.18 2 4
6 13 212.64 25 14.94 622 232 3.40 / 763.41 2 4
7 13 46.60 25 14.98 362 136 3.53 / 763.55 2 4
8 8 0.08 165 14.96 286 706 4.24 / 764.25 2 9
Average= 4.18
(KJ/cycle)

Cycle 181 GMT 12/ 7/2023 17:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 32 14.93 435 208 0.21 / 755.94 2 2
2 12 1171.04 2 15.10 2025 61 0.27 / 756.00 2 2
3 7 2011.08 30 14.68 3017 1329 1.60 / 757.33 2 4
4 13 1695.84 25 14.64 2636 965 2.56 / 758.29 2 3
5 13 968.72 25 14.73 1690 622 3.18 / 758.91 2 4
6 13 238.12 25 14.92 662 247 3.43 / 759.16 2 4
7 13 53.52 25 14.98 373 140 3.57 / 759.30 2 4
8 8 0.08 165 14.96 289 713 4.28 / 760.01 3 10
Average= 4.18
(KJ/cycle)

Cycle 180 GMT 2/ 7/2023 20:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 32 14.94 426 204 0.20 / 751.62 2 2
2 12 1179.12 2 15.11 2012 61 0.26 / 751.68 2 2
3 7 2002.92 31 14.69 3000 1366 1.63 / 753.05 2 4
4 13 1693.52 25 14.65 2634 965 2.60 / 754.01 2 3
5 13 957.88 25 14.73 1677 618 3.21 / 754.63 2 5
6 13 228.04 25 14.93 641 239 3.45 / 754.87 2 4
7 13 51.76 25 14.98 378 142 3.59 / 755.01 2 4
8 8 0.16 165 14.96 291 718 4.31 / 755.73 2 10
Average= 4.18
(KJ/cycle)

Cycle 179 GMT 22/ 6/2023 22:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 32 14.94 429 205 0.21 / 747.36 2 2
2 12 1174.88 2 15.10 2032 61 0.27 / 747.42 2 2
3 7 2005.92 30 14.70 3018 1331 1.60 / 748.75 2 3
4 13 1687.00 25 14.66 2627 963 2.56 / 749.71 2 3
5 13 954.32 25 14.73 1670 615 3.18 / 750.33 2 4
6 13 235.52 25 14.93 652 243 3.42 / 750.57 2 4
7 13 53.44 25 14.98 370 139 3.56 / 750.71 2 4
8 8 0.00 165 14.96 287 708 4.27 / 751.42 2 8
Average= 4.17
(KJ/cycle)

Cycle 178 GMT 13/ 6/2023 0:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 32 14.94 430 206 0.21 / 743.27 2 2
2 12 1180.52 2 15.10 2046 62 0.27 / 743.33 2 3
3 7 2006.00 30 14.69 3019 1330 1.60 / 744.66 3 4
4 13 1538.64 25 14.67 2441 895 2.49 / 745.55 2 4
5 13 835.56 25 14.76 1511 558 3.05 / 746.11 2 4
6 13 169.80 25 14.95 556 208 3.26 / 746.32 2 4
7 13 38.28 25 14.99 344 129 3.39 / 746.45 2 4
8 8 0.12 165 14.96 285 703 4.09 / 747.15 2 9
Average= 4.17
(KJ/cycle)

Cycle 177 GMT 3/ 6/2023 2:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 32 14.94 431 206 0.21 / 739.12 2 2
2 12 1181.76 2 15.10 2033 61 0.27 / 739.18 2 2
3 7 2010.56 30 14.71 3018 1332 1.60 / 740.51 2 3
4 13 1547.76 25 14.68 2451 900 2.50 / 741.41 2 3
5 13 884.20 25 14.75 1582 583 3.08 / 742.00 2 5
6 13 190.00 25 14.95 590 221 3.30 / 742.22 2 4
7 13 44.60 25 14.99 355 133 3.44 / 742.35 2 4
8 8 0.16 165 14.96 288 711 4.15 / 743.06 2 8
Average= 4.17
(KJ/cycle)

Cycle 176 GMT 24/ 5/2023 4:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 32 14.95 435 208 0.21 / 735.00 2 2
2 12 1169.60 2 15.11 2021 61 0.27 / 735.06 2 2
3 7 2004.40 31 14.69 3020 1375 1.64 / 736.44 2 3
4 13 1524.28 25 14.68 2420 888 2.53 / 737.32 2 4
5 13 834.72 25 14.77 1511 558 3.09 / 737.88 2 5
6 13 164.24 25 14.96 538 201 3.29 / 738.08 2 3
7 13 39.04 25 14.99 346 130 3.42 / 738.21 2 4
8 8 0.00 165 14.97 284 701 4.12 / 738.91 2 12
Average= 4.17
(KJ/cycle)

Cycle 175 GMT 14/ 5/2023 6:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 32 14.94 430 206 0.21 / 730.83 2 2
2 12 1175.72 2 15.11 2051 62 0.27 / 730.89 2 2
3 7 2007.84 30 14.69 3015 1329 1.60 / 732.22 2 3
4 13 1703.00 25 14.65 2647 969 2.57 / 733.19 2 4
5 13 841.44 25 14.77 1516 560 3.13 / 733.75 2 5
6 13 172.56 25 14.96 551 206 3.33 / 733.95 2 4
7 13 43.28 25 14.99 353 132 3.46 / 734.09 2 4
8 8 0.12 165 14.97 285 704 4.17 / 734.79 2 9
Average= 4.17
(KJ/cycle)

Cycle 174 GMT 4/ 5/2023 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 32 14.94 431 206 0.21 / 726.55 2 2
2 12 1167.48 2 15.10 2032 61 0.27 / 726.61 2 2
3 7 2007.76 31 14.70 3012 1373 1.64 / 727.98 2 4
4 13 1691.44 25 14.65 2634 965 2.60 / 728.95 2 6
5 13 824.92 25 14.77 1502 555 3.16 / 729.50 2 4
6 13 273.00 25 14.91 714 266 3.43 / 729.77 2 5
7 13 53.72 25 14.98 376 141 3.57 / 729.91 2 4
8 8 0.08 165 14.96 289 713 4.28 / 730.62 2 7
Average= 4.17
(KJ/cycle)

Cycle 173 GMT 24/ 4/2023 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 32 14.94 434 207 0.21 / 722.29 2 2
2 12 1167.88 2 15.10 2014 61 0.27 / 722.35 2 2
3 7 2003.56 30 14.70 3014 1329 1.60 / 723.68 2 3
4 13 1681.08 25 14.66 2620 960 2.56 / 724.64 2 5
5 13 951.76 25 14.74 1660 612 3.17 / 725.25 2 4
6 13 228.52 25 14.94 646 241 3.41 / 725.49 2 4
7 13 50.04 25 14.99 370 139 3.55 / 725.63 2 4
8 8 0.04 165 14.96 290 716 4.27 / 726.34 2 10
Average= 4.17
(KJ/cycle)

Cycle 172 GMT 14/ 4/2023 13:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 32 14.95 433 207 0.21 / 718.01 2 2
2 12 1168.76 2 15.11 2030 61 0.27 / 718.07 2 2
3 7 2004.08 30 14.71 3008 1327 1.60 / 719.39 2 3
4 13 1695.32 25 14.66 2636 966 2.56 / 720.36 2 6
5 13 969.56 25 14.74 1687 622 3.18 / 720.98 2 4
6 13 239.20 25 14.94 657 245 3.43 / 721.23 2 4
7 13 53.28 25 14.99 373 140 3.57 / 721.37 2 4
8 8 0.12 165 14.96 288 711 4.28 / 722.08 2 10
Average= 4.17
(KJ/cycle)

Cycle 171 GMT 4/ 4/2023 15:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 32 14.94 429 205 0.21 / 713.85 2 2
2 12 1166.92 2 15.12 1995 60 0.27 / 713.91 2 2
3 7 2007.88 31 14.70 3017 1375 1.64 / 715.28 2 4
4 13 1538.64 25 14.68 2444 897 2.54 / 716.18 2 3
5 13 861.84 25 14.76 1546 570 3.11 / 716.75 2 5
6 13 177.88 25 14.96 564 211 3.32 / 716.96 2 4
7 13 40.76 25 15.00 352 132 3.45 / 717.09 2 4
8 8 0.08 165 14.97 286 706 4.16 / 717.80 2 9
Average= 4.17
(KJ/cycle)

Cycle 170 GMT 25/ 3/2023 17:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 32 14.94 439 210 0.21 / 709.64 2 2
2 12 1181.24 2 15.10 2027 61 0.27 / 709.70 2 2
3 7 2004.72 30 14.70 3020 1332 1.60 / 711.03 2 4
4 13 1514.32 25 14.69 2409 885 2.49 / 711.92 2 3
5 13 977.60 25 14.74 1703 628 3.12 / 712.55 2 6
6 13 229.92 25 14.94 645 241 3.36 / 712.79 2 4
7 13 48.64 25 14.99 365 137 3.49 / 712.92 2 4
8 8 0.12 165 14.96 291 718 4.21 / 713.64 2 9
Average= 4.17
(KJ/cycle)

Cycle 169 GMT 15/ 3/2023 20:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 32 14.95 432 207 0.21 / 705.33 2 2
2 12 1174.48 2 15.11 2062 62 0.27 / 705.39 2 2
3 7 2010.16 30 14.71 3025 1335 1.60 / 706.73 2 3
4 13 1698.72 25 14.66 2646 970 2.57 / 707.70 2 6
5 13 982.28 25 14.74 1704 628 3.20 / 708.33 2 5
6 13 249.68 25 14.93 682 255 3.46 / 708.58 2 5
7 13 50.32 25 14.99 371 139 3.60 / 708.72 2 4
8 8 0.04 165 14.97 288 711 4.31 / 709.43 2 9
Average= 4.17
(KJ/cycle)

Cycle 168 GMT 5/ 3/2023 22:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 32 14.95 447 214 0.21 / 701.22 2 2
2 12 1183.48 2 15.12 2028 61 0.28 / 701.28 2 2
3 7 2008.64 30 14.71 3015 1331 1.61 / 702.62 2 3
4 13 1544.48 25 14.68 2453 900 2.51 / 703.52 2 3
5 13 860.44 25 14.77 1545 570 3.08 / 704.09 2 5
6 13 188.44 25 14.96 569 213 3.29 / 704.30 2 4
7 13 42.96 25 15.00 349 131 3.42 / 704.43 2 4
8 8 0.08 165 14.97 281 694 4.11 / 705.12 2 11
Average= 4.17
(KJ/cycle)

Cycle 167 GMT 24/ 2/2023 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 32 14.94 426 204 0.20 / 697.01 2 2
2 12 1174.72 2 15.11 2014 61 0.26 / 697.07 2 2
3 7 2004.32 30 14.71 3014 1330 1.59 / 698.40 2 3
4 13 1685.64 25 14.67 2620 961 2.56 / 699.36 2 3
5 13 797.80 25 14.79 1463 541 3.10 / 699.90 2 4
6 13 276.64 25 14.93 714 267 3.36 / 700.17 2 5
7 13 55.72 25 14.99 371 139 3.50 / 700.31 2 4
8 8 0.08 165 14.97 285 704 4.21 / 701.01 2 10
Average= 4.17
(KJ/cycle)

Cycle 166 GMT 14/ 2/2023 2:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 32 14.95 444 212 0.21 / 692.74 2 2
2 12 1166.20 2 15.13 2007 61 0.27 / 692.80 2 3
3 7 2003.08 31 14.71 3010 1373 1.65 / 694.17 3 3
4 13 1536.88 25 14.69 2440 896 2.54 / 695.07 2 3
5 13 995.76 25 14.73 1727 636 3.18 / 695.71 2 5
6 13 240.64 25 14.93 665 248 3.43 / 695.95 2 4
7 13 49.36 25 14.99 369 138 3.56 / 696.09 2 4
8 8 0.08 165 14.96 288 711 4.28 / 696.80 2 11
Average= 4.17
(KJ/cycle)

Cycle 165 GMT 4/ 2/2023 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 32 14.96 431 206 0.21 / 688.62 2 2
2 12 1181.80 2 15.11 2040 62 0.27 / 688.68 2 2
3 7 2007.76 30 14.71 3013 1330 1.60 / 690.01 2 3
4 13 1547.80 25 14.69 2455 902 2.50 / 690.91 2 5
5 13 844.20 25 14.77 1523 562 3.06 / 691.47 2 5
6 13 183.84 25 14.96 570 213 3.27 / 691.68 2 3
7 13 44.96 25 15.00 361 135 3.41 / 691.82 2 4
8 8 0.04 165 14.98 287 709 4.12 / 692.53 2 8
Average= 4.17
(KJ/cycle)

Cycle 164 GMT 25/ 1/2023 7:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 32 14.95 434 208 0.21 / 684.46 2 2
2 12 1167.00 2 15.12 2013 61 0.27 / 684.52 2 2
3 7 2006.12 31 14.70 3017 1375 1.64 / 685.89 2 3
4 13 1534.76 25 14.69 2433 894 2.54 / 686.79 2 3
5 13 858.52 25 14.77 1544 570 3.11 / 687.36 2 5
6 13 183.48 25 14.96 577 216 3.32 / 687.57 2 3
7 13 39.80 25 15.00 349 131 3.45 / 687.70 2 4
8 8 0.08 165 14.98 285 704 4.16 / 688.41 2 10
Average= 4.17
(KJ/cycle)

Cycle 163 GMT 15/ 1/2023 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 32 14.96 433 207 0.21 / 680.21 2 2
2 12 1181.28 2 15.11 2034 61 0.27 / 680.27 2 2
3 7 2007.80 30 14.72 3010 1329 1.60 / 681.60 2 3
4 13 1676.36 25 14.67 2602 954 2.55 / 682.55 2 4
5 13 945.84 25 14.76 1659 612 3.16 / 683.17 2 4
6 13 228.80 25 14.95 644 241 3.41 / 683.41 2 4
7 13 46.12 25 15.00 361 135 3.54 / 683.54 2 4
8 8 0.00 165 14.97 287 709 4.25 / 684.25 2 9
Average= 4.17
(KJ/cycle)

Cycle 162 GMT 5/ 1/2023 11:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 32 14.95 432 207 0.21 / 676.12 2 2
2 12 1170.96 2 15.12 2031 61 0.27 / 676.18 2 2
3 7 2003.32 30 14.71 2999 1323 1.59 / 677.51 2 3
4 13 1535.80 25 14.69 2435 894 2.49 / 678.40 2 3
5 13 843.48 25 14.78 1522 562 3.05 / 678.96 2 5
6 13 167.92 25 14.97 553 207 3.26 / 679.17 2 4
7 13 37.00 25 15.01 342 128 3.38 / 679.30 2 4
8 8 0.08 165 14.98 285 704 4.09 / 680.00 2 8
Average= 4.17
(KJ/cycle)

Cycle 161 GMT 26/12/2022 14: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 32 14.94 450 215 0.22 / 671.87 2 2
2 12 1170.68 2 15.11 2027 61 0.28 / 671.93 2 2
3 7 2008.48 31 14.71 3017 1376 1.65 / 673.30 2 3
4 13 1533.64 25 14.69 2424 890 2.54 / 674.19 2 3
5 13 987.12 25 14.74 1706 629 3.17 / 674.82 2 5
6 13 242.64 25 14.94 669 250 3.42 / 675.07 2 5
7 13 46.44 25 14.99 362 136 3.56 / 675.21 2 4
8 8 0.28 165 14.97 286 706 4.26 / 675.91 2 9
Average= 4.17
(KJ/cycle)

Cycle 160 GMT 16/12/2022 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 32 14.95 444 212 0.21 / 667.32 2 2
2 12 1174.04 2 15.11 2060 62 0.27 / 667.38 2 2
3 7 2002.88 30 14.71 3017 1331 1.61 / 668.71 2 3
4 13 1694.72 25 14.67 2624 962 2.57 / 669.67 2 5
5 13 808.20 25 14.79 1480 547 3.12 / 670.22 2 4
6 13 268.92 25 14.93 714 267 3.38 / 670.49 2 5
7 13 24.48 25 15.00 334 125 3.51 / 670.61 2 4
8 8 0.12 165 14.98 290 717 4.22 / 671.33 2 11
9 14 0.12 75 14.94 287 322 4.55 / 671.65 3 13
Average= 4.17
(KJ/cycle)

Cycle 159 GMT 6/12/2022 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 32 14.95 436 209 0.21 / 663.03 2 2
2 12 1172.36 2 15.13 2025 61 0.27 / 663.09 2 3
3 7 2007.96 30 14.72 3015 1331 1.60 / 664.43 3 3
4 13 1688.56 25 14.67 2636 967 2.57 / 665.39 2 6
5 13 952.84 25 14.76 1679 620 3.19 / 666.01 2 5
6 13 217.92 25 14.96 642 240 3.43 / 666.25 2 5
7 13 24.32 25 15.01 336 126 3.55 / 666.38 2 4
8 8 0.12 165 14.98 294 727 4.28 / 667.10 2 9
Average= 4.17
(KJ/cycle)

Cycle 158 GMT 26/11/2022 20:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 32 14.95 436 209 0.21 / 658.82 2 2
2 12 1184.08 2 15.12 2030 61 0.27 / 658.88 2 2
3 7 2005.32 30 14.71 3007 1327 1.60 / 660.21 2 3
4 13 1526.56 25 14.70 2429 893 2.49 / 661.10 2 3
5 13 977.68 25 14.75 1702 628 3.12 / 661.73 2 5
6 13 214.96 25 14.95 630 235 3.35 / 661.97 2 4
7 13 20.76 25 15.01 335 126 3.48 / 662.09 2 4
8 8 0.08 165 14.97 296 731 4.21 / 662.82 2 8
Average= 4.17
(KJ/cycle)

Cycle 157 GMT 16/11/2022 23:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 32 14.95 436 209 0.21 / 654.58 2 2
2 12 1187.32 2 15.12 2029 61 0.27 / 654.64 2 2
3 7 2004.60 30 14.71 3020 1333 1.60 / 655.97 2 3
4 13 1687.72 25 14.67 2625 963 2.57 / 656.94 2 4
5 13 925.92 25 14.77 1636 604 3.17 / 657.54 2 5
6 13 196.52 25 14.96 597 223 3.39 / 657.76 2 4
7 13 19.56 25 15.01 327 123 3.52 / 657.89 2 4
8 8 0.20 165 14.98 295 729 4.24 / 658.61 2 11
Average= 4.17
(KJ/cycle)

Cycle 156 GMT 7/11/2022 1:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 32 14.95 435 208 0.21 / 650.35 2 2
2 12 1192.88 2 15.12 2059 62 0.27 / 650.41 2 2
3 7 2007.08 30 14.72 3022 1335 1.60 / 651.74 2 3
4 13 1683.44 25 14.68 2629 965 2.57 / 652.71 2 5
5 13 808.76 25 14.80 1476 546 3.12 / 653.26 2 4
6 13 260.92 25 14.94 699 261 3.38 / 653.52 2 5
7 13 21.92 25 15.01 333 125 3.50 / 653.64 2 4
8 8 -0.04 165 14.97 295 729 4.23 / 654.37 2 10
Average= 4.17
(KJ/cycle)

Cycle 155 GMT 28/10/2022 3:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 32 14.96 414 198 0.20 / 646.20 2 2
2 12 1181.88 2 15.12 2036 62 0.26 / 646.26 2 2
3 7 2002.76 30 14.72 3014 1331 1.59 / 647.59 2 3
4 13 1700.52 25 14.67 2648 971 2.56 / 648.56 2 6
5 13 962.64 25 14.75 1682 620 3.18 / 649.18 2 5
6 13 228.24 25 14.94 651 243 3.43 / 649.43 2 4
7 8 0.20 165 14.98 288 712 4.14 / 650.14 2 7
Average= 4.17
(KJ/cycle)

Cycle 154 GMT 18/10/2022 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 32 14.97 447 214 0.21 / 641.98 2 2
2 12 1165.24 2 15.13 2010 61 0.27 / 642.04 2 3
3 7 2005.72 30 14.72 3012 1330 1.61 / 643.37 3 3
4 13 1683.72 25 14.68 2617 960 2.57 / 644.33 2 5
5 13 829.68 25 14.79 1504 556 3.12 / 644.89 2 4
6 13 269.52 25 14.94 714 267 3.39 / 645.15 2 4
7 13 23.24 25 15.01 329 123 3.51 / 645.28 2 4
8 8 0.12 165 14.98 294 727 4.24 / 646.00 2 10
Average= 4.17
(KJ/cycle)

Cycle 153 GMT 8/10/2022 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 32 14.96 432 207 0.21 / 637.83 2 2
2 12 1172.40 2 15.13 2027 61 0.27 / 637.89 2 2
3 7 2006.08 31 14.71 3006 1371 1.64 / 639.26 2 3
4 13 1527.00 25 14.70 2423 890 2.53 / 640.15 2 3
5 13 995.12 25 14.75 1726 636 3.17 / 640.79 2 5
6 13 234.52 25 14.95 661 247 3.41 / 641.03 2 4
7 8 0.20 165 14.99 295 730 4.14 / 641.76 2 8
Average= 4.17
(KJ/cycle)

Cycle 152 GMT 28/ 9/2022 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 32 14.98 431 207 0.21 / 633.59 2 2
2 12 1172.84 2 15.12 2019 61 0.27 / 633.66 2 2
3 7 2003.36 30 14.71 3012 1329 1.60 / 634.99 2 4
4 13 1687.88 25 14.67 2622 962 2.56 / 635.95 2 6
5 13 942.24 25 14.76 1657 611 3.17 / 636.56 2 5
6 13 216.12 25 14.96 625 234 3.40 / 636.79 2 4
7 13 18.88 25 15.02 319 120 3.52 / 636.91 2 4
8 8 0.08 165 14.99 287 710 4.23 / 637.62 2 10
Average= 4.17
(KJ/cycle)

Cycle 151 GMT 18/ 9/2022 11:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 32 14.98 450 216 0.22 / 629.60 2 2
2 12 1173.12 2 15.12 2029 61 0.28 / 629.66 2 2
3 7 2007.28 30 14.72 3009 1329 1.61 / 630.99 2 4
4 13 1543.16 25 14.70 2453 901 2.51 / 631.89 2 5
5 13 863.84 25 14.78 1551 573 3.08 / 632.47 2 5
6 13 172.72 25 14.98 553 207 3.29 / 632.67 2 3
7 8 0.12 165 15.00 289 715 4.00 / 633.39 2 9
Average= 4.17
(KJ/cycle)

Cycle 150 GMT 8/ 9/2022 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 32 14.97 439 210 0.21 / 625.44 2 2
2 12 1171.72 2 15.12 2029 61 0.27 / 625.51 2 2
3 7 2008.44 30 14.73 3016 1333 1.60 / 626.84 2 3
4 13 1693.32 25 14.67 2644 970 2.57 / 627.81 2 4
5 13 960.12 25 14.76 1681 620 3.19 / 628.43 2 4
6 13 237.72 25 14.96 660 247 3.44 / 628.68 2 4
7 8 0.24 165 15.00 287 710 4.15 / 629.39 2 10
Average= 4.17
(KJ/cycle)

Cycle 149 GMT 29/ 8/2022 16:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 32 14.97 441 211 0.21 / 621.34 2 2
2 12 1170.44 2 15.13 2023 61 0.27 / 621.40 2 2
3 7 2006.08 31 14.71 3017 1376 1.65 / 622.78 2 3
4 13 1529.20 25 14.70 2425 891 2.54 / 623.67 2 4
5 13 840.32 25 14.79 1517 561 3.10 / 624.23 2 5
6 13 279.44 25 14.94 736 275 3.38 / 624.50 2 4
7 8 0.08 165 15.00 295 730 4.11 / 625.23 2 6
Average= 4.17
(KJ/cycle)

Cycle 148 GMT 19/ 8/2022 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 32 14.98 436 209 0.21 / 617.17 2 2
2 12 1161.12 2 15.13 1997 60 0.27 / 617.23 2 2
3 7 2005.20 31 14.72 3022 1379 1.65 / 618.61 2 3
4 13 1673.64 25 14.67 2621 961 2.61 / 619.57 2 6
5 13 925.68 25 14.77 1636 604 3.21 / 620.18 2 4
6 13 194.00 25 14.98 591 221 3.44 / 620.40 2 4
7 8 0.08 165 15.00 295 730 4.17 / 621.13 2 9
Average= 4.17
(KJ/cycle)

Cycle 147 GMT 9/ 8/2022 20:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 32 14.99 431 207 0.21 / 613.04 2 2
2 12 1165.64 2 15.13 2003 61 0.27 / 613.10 2 2
3 7 2004.84 30 14.73 3010 1330 1.60 / 614.43 2 2
4 13 1684.20 25 14.68 2619 961 2.56 / 615.39 2 4
5 13 958.24 25 14.77 1668 616 3.17 / 616.00 2 4
6 13 226.24 25 14.97 641 240 3.41 / 616.24 2 4
7 8 0.12 165 15.00 291 720 4.13 / 616.96 2 7
Average= 4.17
(KJ/cycle)

Cycle 146 GMT 30/ 7/2022 22:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 32 14.97 440 211 0.21 / 608.91 2 2
2 12 1162.16 2 15.12 2011 61 0.27 / 608.97 2 2
3 7 2003.12 30 14.72 3015 1331 1.60 / 610.30 2 3
4 13 1694.76 25 14.68 2630 965 2.57 / 611.27 2 6
5 13 958.28 25 14.77 1676 619 3.19 / 611.89 2 5
6 13 222.88 25 14.97 635 238 3.42 / 612.12 2 4
7 8 0.24 165 15.01 285 706 4.13 / 612.83 2 8
Average= 4.17
(KJ/cycle)

Cycle 145 GMT 21/ 7/2022 1:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 32 14.97 442 212 0.21 / 604.81 2 2
2 12 1174.40 2 15.13 2024 61 0.27 / 604.87 2 2
3 7 2003.72 31 14.72 3012 1374 1.65 / 606.25 2 3
4 13 1543.08 25 14.70 2440 897 2.54 / 607.14 2 3
5 13 847.60 25 14.79 1531 566 3.11 / 607.71 2 5
6 13 283.28 25 14.94 730 273 3.38 / 607.98 2 4
7 8 0.08 165 15.00 289 715 4.10 / 608.70 2 8
Average= 4.17
(KJ/cycle)

Cycle 144 GMT 11/ 7/2022 3:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 32 14.96 434 208 0.21 / 600.53 2 2
2 12 1174.36 2 15.12 2062 62 0.27 / 600.59 2 2
3 7 2007.92 30 14.72 3024 1335 1.61 / 601.93 2 3
4 13 1685.84 25 14.68 2619 961 2.57 / 602.89 2 5
5 13 954.60 25 14.77 1672 617 3.18 / 603.51 2 5
6 13 225.40 25 14.97 639 239 3.42 / 603.74 2 4
7 13 44.28 25 15.02 360 135 3.56 / 603.88 2 4
8 8 0.12 165 15.00 291 720 4.28 / 604.60 2 8
Average= 4.17
(KJ/cycle)

Cycle 143 GMT 1/ 7/2022 5:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 32 14.96 437 209 0.21 / 596.32 2 2
2 12 1174.16 2 15.14 2001 61 0.27 / 596.38 2 2
3 7 2012.28 30 14.72 3028 1337 1.61 / 597.72 2 3
4 13 1684.44 25 14.68 2609 958 2.56 / 598.67 2 4
5 13 794.08 25 14.81 1459 540 3.10 / 599.21 2 5
6 13 243.64 25 14.96 673 252 3.36 / 599.47 2 4
7 13 47.48 25 15.01 369 138 3.49 / 599.60 2 4
8 8 0.00 165 14.99 290 717 4.21 / 600.32 2 7
Average= 4.17
(KJ/cycle)

Cycle 142 GMT 21/ 6/2022 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 32 14.98 450 216 0.22 / 592.04 2 2
2 12 1178.60 2 15.13 2027 61 0.28 / 592.10 2 2
3 7 2004.32 31 14.72 3012 1374 1.65 / 593.48 2 3
4 13 1678.04 25 14.69 2618 961 2.61 / 594.44 2 3
5 13 810.40 25 14.81 1475 546 3.16 / 594.98 2 5
6 13 271.48 25 14.95 711 266 3.42 / 595.25 2 4
7 13 52.48 25 15.01 375 141 3.57 / 595.39 2 4
8 8 0.08 165 14.99 291 720 4.29 / 596.11 2 7
Average= 4.17
(KJ/cycle)

Cycle 141 GMT 11/ 6/2022 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 32 14.97 441 211 0.21 / 587.77 2 2
2 12 1166.84 2 15.13 2013 61 0.27 / 587.83 2 2
3 7 2009.24 30 14.72 3007 1328 1.60 / 589.16 2 3
4 13 1686.12 25 14.69 2624 964 2.56 / 590.12 2 5
5 13 967.80 25 14.77 1687 623 3.19 / 590.74 2 5
6 13 226.44 25 14.97 636 238 3.42 / 590.98 2 4
7 13 47.40 25 15.02 362 136 3.56 / 591.12 2 4
8 8 0.16 165 15.00 286 708 4.27 / 591.82 2 8
Average= 4.17
(KJ/cycle)

Cycle 140 GMT 1/ 6/2022 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 32 14.97 441 211 0.21 / 583.45 2 2
2 12 1176.72 2 15.14 2015 61 0.27 / 583.51 2 2
3 7 2004.60 31 14.73 3008 1374 1.65 / 584.88 2 3
4 13 1681.04 25 14.69 2617 961 2.61 / 585.84 2 5
5 13 958.48 25 14.77 1674 618 3.23 / 586.46 2 4
6 13 228.64 25 14.97 650 243 3.47 / 586.71 2 4
7 13 51.80 25 15.02 370 139 3.61 / 586.85 2 4
8 8 0.04 165 15.00 287 710 4.32 / 587.56 2 9
Average= 4.17
(KJ/cycle)

Cycle 139 GMT 22/ 5/2022 14:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 32 14.97 442 212 0.21 / 579.19 2 2
2 12 1170.44 2 15.14 2016 61 0.27 / 579.25 2 2
3 7 2004.84 30 14.73 2999 1325 1.60 / 580.58 2 4
4 13 1685.92 25 14.69 2629 966 2.56 / 581.54 2 4
5 13 819.84 25 14.81 1491 552 3.12 / 582.10 2 4
6 13 258.84 25 14.96 696 260 3.38 / 582.36 2 4
7 13 53.80 25 15.02 383 144 3.52 / 582.50 2 4
8 8 0.16 165 14.99 298 737 4.26 / 583.24 2 9
Average= 4.17
(KJ/cycle)

Cycle 138 GMT 12/ 5/2022 17:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 32 14.96 429 205 0.21 / 574.91 2 2
2 12 1182.08 2 15.15 2025 61 0.27 / 574.97 2 2
3 7 2008.32 30 14.73 3024 1336 1.60 / 576.31 2 3
4 13 1673.72 25 14.69 2614 960 2.56 / 577.27 2 4
5 13 929.00 25 14.78 1641 606 3.17 / 577.87 2 4
6 13 205.80 25 14.98 618 231 3.40 / 578.10 2 4
7 13 46.12 25 15.02 370 139 3.54 / 578.24 2 4
8 8 0.00 165 15.00 298 738 4.28 / 578.98 2 9
Average= 4.17
(KJ/cycle)

Cycle 137 GMT 2/ 5/2022 19:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 32 14.96 419 201 0.20 / 570.67 2 2
2 12 1167.16 2 15.14 2014 61 0.26 / 570.73 2 2
3 7 2007.32 31 14.73 3012 1375 1.64 / 572.10 2 3
4 13 1537.28 25 14.71 2437 896 2.53 / 573.00 2 4
5 13 824.88 25 14.81 1496 554 3.09 / 573.55 2 5
6 13 266.40 25 14.95 714 267 3.35 / 573.82 2 4
7 13 50.44 25 15.01 381 143 3.50 / 573.96 2 4
8 8 0.08 165 14.98 299 739 4.24 / 574.70 2 9
Average= 4.16
(KJ/cycle)

Cycle 136 GMT 22/ 4/2022 21:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 32 14.99 413 198 0.20 / 566.58 2 2
2 12 1166.56 2 15.13 2006 61 0.26 / 566.64 2 2
3 7 2008.44 30 14.73 3016 1333 1.59 / 567.97 2 4
4 13 1520.24 25 14.72 2416 889 2.48 / 568.86 2 5
5 13 829.80 25 14.80 1508 558 3.04 / 569.42 2 4
6 13 162.32 25 14.99 544 204 3.24 / 569.62 2 3
7 13 40.20 25 15.01 354 133 3.38 / 569.75 2 4
8 8 0.04 165 14.99 289 715 4.09 / 570.47 2 11
Average= 4.16
(KJ/cycle)

Cycle 135 GMT 12/ 4/2022 23: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 32 14.97 434 208 0.21 / 562.30 2 2
2 12 1186.48 2 15.14 2047 62 0.27 / 562.36 2 2
3 7 2006.12 30 14.74 3017 1334 1.60 / 563.69 2 3
4 13 1681.80 25 14.70 2624 964 2.57 / 564.66 2 3
5 13 953.04 25 14.78 1673 618 3.19 / 565.28 2 4
6 13 229.40 25 14.98 648 243 3.43 / 565.52 2 4
7 13 49.80 25 15.03 375 141 3.57 / 565.66 2 4
8 8 0.08 165 15.01 290 718 4.29 / 566.38 2 10
Average= 4.16
(KJ/cycle)

Cycle 134 GMT 3/ 4/2022 1:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 32 14.98 439 210 0.21 / 558.01 2 2
2 12 1164.28 2 15.14 2025 61 0.27 / 558.07 2 2
3 7 2009.68 30 14.73 3019 1334 1.61 / 559.41 2 3
4 13 1694.76 25 14.69 2644 971 2.58 / 560.38 2 4
5 13 824.64 25 14.81 1506 558 3.13 / 560.94 2 5
6 13 277.44 25 14.96 727 272 3.41 / 561.21 2 4
7 13 49.48 25 15.02 375 141 3.55 / 561.35 2 4
8 8 0.08 165 15.00 299 740 4.29 / 562.09 2 11
Average= 4.16
(KJ/cycle)

Cycle 133 GMT 24/ 3/2022 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 32 14.98 446 214 0.21 / 553.73 2 2
2 12 1174.04 2 15.14 2043 62 0.28 / 553.79 2 2
3 7 2010.72 30 14.73 3028 1338 1.61 / 555.13 2 3
4 13 1679.44 25 14.69 2624 964 2.58 / 556.09 2 4
5 13 945.00 25 14.78 1663 614 3.19 / 556.71 2 5
6 13 211.24 25 14.99 624 234 3.43 / 556.94 2 4
7 13 47.16 25 15.03 369 139 3.56 / 557.08 2 4
8 8 0.12 165 15.01 291 721 4.29 / 557.80 2 10
Average= 4.16
(KJ/cycle)

Cycle 132 GMT 14/ 3/2022 5:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 32 14.97 443 212 0.21 / 549.44 2 2
2 12 1169.92 2 15.14 2017 61 0.27 / 549.50 2 2
3 7 2005.84 30 14.74 3009 1331 1.60 / 550.83 2 3
4 13 1677.32 25 14.69 2616 961 2.56 / 551.79 2 5
5 13 953.64 25 14.78 1668 616 3.18 / 552.40 2 5
6 13 223.52 25 14.98 645 242 3.42 / 552.65 2 4
7 13 43.76 25 15.03 369 139 3.56 / 552.78 2 4
8 8 0.08 165 15.01 296 733 4.29 / 553.52 2 9
Average= 4.16
(KJ/cycle)

Cycle 131 GMT 4/ 3/2022 8: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 32 14.98 441 211 0.21 / 545.20 2 2
2 12 1170.04 2 15.15 2019 61 0.27 / 545.26 2 3
3 7 2008.88 30 14.73 3028 1338 1.61 / 546.60 3 4
4 13 1537.56 25 14.72 2438 897 2.51 / 547.50 2 5
5 13 851.52 25 14.81 1534 568 3.08 / 548.07 2 4
6 13 282.56 25 14.96 739 276 3.35 / 548.34 2 5
7 13 48.88 25 15.02 376 141 3.49 / 548.49 2 4
8 8 0.12 165 15.00 298 738 4.23 / 549.22 2 10
Average= 4.16
(KJ/cycle)

Cycle 130 GMT 22/ 2/2022 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 32 14.98 443 212 0.21 / 540.91 2 2
2 12 1182.04 2 15.14 2025 61 0.27 / 540.97 2 2
3 7 2005.56 30 14.73 3016 1333 1.61 / 542.31 2 4
4 13 1683.64 25 14.69 2617 961 2.57 / 543.27 2 4
5 13 961.12 25 14.78 1687 623 3.19 / 543.89 2 4
6 13 219.88 25 14.99 637 239 3.43 / 544.13 2 4
7 13 42.96 25 15.04 363 136 3.57 / 544.27 2 4
8 8 0.20 165 15.01 293 726 4.29 / 544.99 2 8
Average= 4.16
(KJ/cycle)

Cycle 129 GMT 12/ 2/2022 12:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 32 14.99 443 212 0.21 / 536.82 2 2
2 12 1167.60 2 15.14 2007 61 0.27 / 536.88 2 2
3 7 2003.56 30 14.73 3019 1334 1.61 / 538.22 2 4
4 13 1527.92 25 14.72 2438 897 2.50 / 539.11 2 4
5 13 696.28 25 14.85 1327 493 3.00 / 539.61 2 4
6 13 188.60 25 15.00 593 222 3.22 / 539.83 2 4
7 13 40.88 25 15.04 362 136 3.36 / 539.96 2 4
8 8 0.08 165 15.01 297 736 4.09 / 540.70 2 10
Average= 4.16
(KJ/cycle)

Cycle 128 GMT 2/ 2/2022 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 32 14.99 435 209 0.21 / 532.67 2 2
2 12 1169.60 2 15.14 2014 61 0.27 / 532.73 2 2
3 7 2012.20 30 14.73 3027 1338 1.61 / 534.07 2 4
4 13 1559.16 25 14.71 2478 911 2.52 / 534.98 2 5
5 13 859.36 25 14.81 1547 573 3.09 / 535.55 2 4
6 13 173.68 25 15.01 559 210 3.30 / 535.76 2 4
7 13 19.28 25 15.05 323 122 3.42 / 535.89 2 4
8 8 0.00 165 15.01 292 723 4.15 / 536.61 2 7
Average= 4.16
(KJ/cycle)

Cycle 127 GMT 23/ 1/2022 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 32 14.98 446 214 0.21 / 528.50 2 2
2 12 1181.72 2 15.15 2036 62 0.28 / 528.56 2 2
3 7 2012.08 30 14.74 3028 1339 1.61 / 529.90 2 3
4 13 1557.52 25 14.72 2460 905 2.52 / 530.80 2 3
5 13 868.96 25 14.81 1563 579 3.10 / 531.38 2 5
6 13 179.00 25 15.01 573 215 3.31 / 531.60 2 4
7 13 45.04 25 15.04 370 139 3.45 / 531.73 2 4
8 8 0.20 165 15.02 294 729 4.18 / 532.46 2 11
Average= 4.16
(KJ/cycle)

Cycle 126 GMT 13/ 1/2022 18:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 32 14.98 446 214 0.21 / 524.17 2 2
2 12 1172.24 2 15.14 2034 62 0.28 / 524.24 2 2
3 7 2004.96 30 14.74 3018 1335 1.61 / 525.57 2 3
4 13 1684.00 25 14.70 2628 966 2.58 / 526.54 2 6
5 13 949.88 25 14.79 1674 619 3.19 / 527.16 2 5
6 13 235.48 25 14.99 662 248 3.44 / 527.40 2 4
7 13 46.88 25 15.04 373 140 3.58 / 527.54 2 4
8 8 0.08 165 15.01 298 738 4.32 / 528.28 2 7
Average= 4.16
(KJ/cycle)

Cycle 125 GMT 3/ 1/2022 20:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 31 14.99 450 209 0.21 / 519.88 2 2
2 12 1177.80 2 15.13 2039 62 0.27 / 519.94 2 2
3 7 2010.96 30 14.73 3033 1340 1.61 / 521.28 2 3
4 13 1689.92 25 14.69 2636 968 2.58 / 522.25 2 7
5 13 821.28 25 14.82 1506 558 3.14 / 522.81 2 4
6 13 261.16 25 14.97 708 265 3.40 / 523.08 2 4
7 13 47.48 25 15.03 378 142 3.54 / 523.22 2 4
8 8 0.04 165 15.01 300 743 4.29 / 523.96 2 10
Average= 4.16
(KJ/cycle)

Cycle 124 GMT 24/12/2021 23: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 31 14.99 442 205 0.21 / 515.72 2 2
2 12 1184.48 2 15.14 2037 62 0.27 / 515.78 2 2
3 7 2009.40 30 14.75 3023 1338 1.60 / 517.12 2 3
4 13 1551.48 25 14.72 2455 903 2.51 / 518.02 2 4
5 13 856.64 25 14.82 1542 571 3.08 / 518.59 2 4
6 13 172.76 25 15.01 572 215 3.29 / 518.81 2 3
7 13 17.48 25 15.05 327 123 3.42 / 518.93 2 4
8 8 0.08 165 15.02 300 743 4.16 / 519.67 2 10
Average= 4.16
(KJ/cycle)

Cycle 123 GMT 15/12/2021 1:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 31 15.01 441 205 0.21 / 511.47 2 2
2 12 1331.36 2 15.11 2244 68 0.27 / 511.54 2 2
3 7 2007.36 30 14.73 3012 1331 1.60 / 512.87 2 4
4 13 1688.20 25 14.69 2635 968 2.57 / 513.84 2 6
5 13 799.12 25 14.83 1467 544 3.12 / 514.38 2 5
6 13 262.36 25 14.98 703 263 3.38 / 514.64 2 4
7 13 22.24 25 15.05 340 128 3.51 / 514.77 2 4
8 8 0.04 165 15.01 300 743 4.25 / 515.51 2 10
Average= 4.16
(KJ/cycle)

Cycle 122 GMT 5/12/2021 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 31 14.99 438 204 0.20 / 507.48 2 2
2 12 1174.64 2 15.15 2032 62 0.27 / 507.54 2 2
3 7 2008.08 30 14.74 3018 1335 1.60 / 508.87 2 3
4 13 1529.56 25 14.73 2429 894 2.49 / 509.77 2 4
5 13 827.36 25 14.83 1507 559 3.05 / 510.33 2 5
6 13 162.88 25 15.02 549 206 3.26 / 510.53 2 4
7 8 0.20 165 15.03 295 732 3.99 / 511.26 2 10
Average= 4.16
(KJ/cycle)

Cycle 121 GMT 25/11/2021 5:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 31 15.00 447 208 0.21 / 503.12 2 2
2 12 1178.20 2 15.15 2032 62 0.27 / 503.18 2 2
3 7 2006.92 31 14.73 3025 1381 1.65 / 504.56 2 3
4 13 1694.32 25 14.70 2639 970 2.62 / 505.53 2 6
5 13 967.00 25 14.79 1687 624 3.24 / 506.16 2 5
6 13 231.68 25 14.99 663 248 3.49 / 506.41 2 4
7 13 21.16 25 15.05 334 126 3.62 / 506.53 2 4
8 8 0.12 165 15.02 299 741 4.36 / 507.27 2 10
Average= 4.16
(KJ/cycle)

Cycle 120 GMT 15/11/2021 7:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 31 14.99 440 204 0.20 / 499.10 2 2
2 12 1185.44 2 15.15 2045 62 0.27 / 499.16 2 3
3 7 2007.00 30 14.74 3010 1331 1.60 / 500.49 3 3
4 13 1537.92 25 14.73 2443 900 2.50 / 501.39 2 3
5 13 859.04 25 14.82 1558 577 3.07 / 501.97 2 5
6 13 171.68 25 15.02 562 211 3.29 / 502.18 2 3
7 8 0.24 165 15.03 295 732 4.02 / 502.91 2 8
Average= 4.16
(KJ/cycle)

Cycle 119 GMT 5/11/2021 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 31 15.00 442 206 0.21 / 494.79 2 2
2 12 1179.12 2 15.14 2047 62 0.27 / 494.86 2 2
3 7 2002.68 30 14.74 3006 1329 1.60 / 496.18 2 4
4 13 1677.08 25 14.71 2616 962 2.56 / 497.15 2 5
5 13 968.16 25 14.79 1691 625 3.18 / 497.77 2 5
6 13 224.60 25 15.00 649 243 3.43 / 498.02 2 4
7 13 43.80 25 15.04 373 140 3.57 / 498.16 2 4
8 8 0.20 165 15.02 299 741 4.31 / 498.90 2 9
Average= 4.16
(KJ/cycle)

Cycle 118 GMT 26/10/2021 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 31 14.99 451 210 0.21 / 490.52 2 2
2 12 1321.32 2 15.10 2243 68 0.28 / 490.59 2 2
3 7 2005.56 30 14.75 3022 1337 1.61 / 491.93 2 3
4 13 1534.08 25 14.73 2440 899 2.51 / 492.83 2 4
5 13 1000.76 25 14.78 1739 643 3.16 / 493.47 2 4
6 13 257.16 25 14.99 694 260 3.42 / 493.73 2 4
7 13 24.40 25 15.05 336 126 3.54 / 493.86 2 4
8 8 0.08 165 15.02 295 731 4.27 / 494.59 2 10
Average= 4.16
(KJ/cycle)

Cycle 117 GMT 16/10/2021 14:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 15.00 441 205 0.21 / 486.22 2 2
2 12 1171.08 2 15.15 2033 62 0.27 / 486.28 2 3
3 7 2005.24 30 14.75 3025 1339 1.61 / 487.62 3 3
4 13 1692.88 25 14.70 2633 968 2.57 / 488.59 2 5
5 13 954.28 25 14.80 1681 622 3.19 / 489.21 2 5
6 13 232.44 25 15.00 652 244 3.44 / 489.46 2 4
7 13 23.48 25 15.06 333 125 3.56 / 489.58 2 4
8 8 0.08 165 15.02 296 734 4.30 / 490.31 2 7
Average= 4.16
(KJ/cycle)

Cycle 116 GMT 6/10/2021 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 31 15.00 452 210 0.21 / 481.95 2 2
2 12 1175.96 2 15.15 2026 61 0.27 / 482.02 2 2
3 7 2008.88 30 14.74 3017 1334 1.61 / 483.35 2 4
4 13 1684.56 25 14.70 2628 966 2.57 / 484.32 2 3
5 13 927.08 25 14.81 1641 608 3.18 / 484.92 2 5
6 13 208.80 25 15.01 614 230 3.41 / 485.15 2 4
7 13 41.04 25 15.05 356 134 3.54 / 485.29 2 4
8 8 0.04 165 15.03 294 729 4.27 / 486.02 2 9
Average= 4.15
(KJ/cycle)

Cycle 115 GMT 26/ 9/2021 18:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 31 15.02 439 204 0.20 / 477.93 2 2
2 12 1174.40 2 15.15 2006 61 0.27 / 477.99 2 2
3 7 2007.48 30 14.74 3028 1339 1.60 / 479.33 2 4
4 13 1514.92 25 14.74 2412 889 2.49 / 480.21 2 4
5 13 792.00 25 14.84 1460 542 3.03 / 480.76 2 5
6 13 249.68 25 14.99 688 258 3.29 / 481.01 2 4
7 8 0.04 165 15.04 294 730 4.02 / 481.74 2 10
Average= 4.15
(KJ/cycle)

Cycle 114 GMT 16/ 9/2021 20:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 31 15.01 442 206 0.21 / 473.90 2 2
2 12 1176.64 2 15.16 2032 62 0.27 / 473.96 2 3
3 7 2011.68 30 14.75 3028 1340 1.61 / 475.30 3 3
4 13 1548.12 25 14.73 2451 903 2.51 / 476.20 2 4
5 13 867.68 25 14.82 1567 581 3.09 / 476.78 2 5
6 13 183.20 25 15.02 573 215 3.31 / 477.00 2 4
7 8 0.08 165 15.04 292 725 4.03 / 477.72 2 5
Average= 4.15
(KJ/cycle)

Cycle 113 GMT 6/ 9/2021 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 31 15.01 442 206 0.21 / 469.86 2 2
2 12 1321.52 2 15.11 2234 68 0.27 / 469.93 2 2
3 7 2011.96 30 14.74 3027 1339 1.61 / 471.27 2 3
4 13 1541.08 25 14.73 2440 899 2.51 / 472.17 2 3
5 13 849.92 25 14.83 1533 568 3.08 / 472.74 2 4
6 13 175.68 25 15.02 571 214 3.29 / 472.95 2 3
7 8 0.08 165 15.04 299 742 4.04 / 473.69 2 11
Average= 4.16
(KJ/cycle)

Cycle 112 GMT 28/ 8/2021 0:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 31 15.02 441 205 0.21 / 465.86 2 2
2 12 1317.68 2 15.11 2232 67 0.27 / 465.93 2 2
3 7 2004.36 30 14.74 3014 1333 1.61 / 467.26 2 3
4 13 1530.92 25 14.74 2432 896 2.50 / 468.16 2 4
5 13 831.92 25 14.83 1508 559 3.06 / 468.72 2 4
6 13 168.48 25 15.03 549 206 3.27 / 468.92 2 3
7 8 0.12 165 15.04 296 735 4.00 / 469.66 2 9
Average= 4.16
(KJ/cycle)

Cycle 111 GMT 18/ 8/2021 2:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 15.02 431 201 0.20 / 461.87 2 2
2 12 1163.84 2 15.15 1999 61 0.26 / 461.93 2 2
3 7 2004.80 30 14.74 3019 1335 1.60 / 463.26 2 3
4 13 1530.44 25 14.74 2429 895 2.49 / 464.16 2 5
5 13 837.24 25 14.83 1520 564 3.05 / 464.72 2 4
6 13 172.12 25 15.03 557 209 3.26 / 464.93 2 3
7 8 0.08 165 15.04 292 725 3.99 / 465.65 2 7
Average= 4.16
(KJ/cycle)

Cycle 110 GMT 8/ 8/2021 4:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 31 15.01 462 215 0.21 / 457.66 2 2
2 12 1174.60 2 15.16 2029 62 0.28 / 457.72 2 2
3 7 2006.76 30 14.76 3015 1335 1.61 / 459.06 2 4
4 13 1683.36 25 14.72 2633 969 2.58 / 460.03 2 5
5 13 1111.12 25 14.77 1886 696 3.28 / 460.72 2 4
6 13 194.84 25 15.03 597 224 3.50 / 460.95 2 4
7 8 0.00 165 15.06 289 718 4.22 / 461.67 2 9
Average= 4.16
(KJ/cycle)

Cycle 109 GMT 29/ 7/2021 7:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 31 15.01 446 208 0.21 / 453.57 2 2
2 12 1172.60 2 15.16 2033 62 0.27 / 453.63 2 2
3 7 2005.16 30 14.75 3024 1338 1.61 / 454.97 2 3
4 13 1527.96 25 14.74 2432 896 2.50 / 455.87 2 4
5 13 835.28 25 14.83 1516 562 3.07 / 456.43 2 4
6 13 287.48 25 14.98 745 279 3.34 / 456.71 2 4
7 8 0.08 165 15.04 298 740 4.08 / 457.45 2 10
Average= 4.16
(KJ/cycle)

Cycle 108 GMT 19/ 7/2021 9:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 31 15.01 465 216 0.22 / 449.24 2 2
2 12 1172.72 2 15.16 2020 61 0.28 / 449.30 2 2
3 7 2006.16 30 14.75 3029 1340 1.62 / 450.64 2 4
4 13 1689.72 25 14.71 2647 973 2.59 / 451.62 2 6
5 13 951.88 25 14.81 1674 620 3.21 / 452.24 2 5
6 13 225.48 25 15.01 645 242 3.45 / 452.48 2 4
7 13 45.76 25 15.06 375 141 3.59 / 452.62 2 4
8 8 0.12 165 15.03 299 742 4.34 / 453.36 2 10
Average= 4.16
(KJ/cycle)

Cycle 107 GMT 9/ 7/2021 11:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 31 15.01 450 209 0.21 / 445.07 2 2
2 12 1164.36 2 15.16 2039 62 0.27 / 445.13 2 2
3 7 2004.60 30 14.76 3023 1339 1.61 / 446.47 2 4
4 13 1692.08 25 14.71 2644 972 2.58 / 447.44 2 4
5 13 819.16 25 14.84 1502 557 3.14 / 448.00 2 5
6 13 286.88 25 14.99 748 280 3.42 / 448.28 2 5
7 8 0.04 165 15.04 301 747 4.17 / 449.03 2 8
Average= 4.16
(KJ/cycle)

Cycle 106 GMT 29/ 6/2021 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 31 15.00 426 198 0.20 / 440.92 2 2
2 12 1186.00 2 15.16 2027 61 0.26 / 440.99 2 2
3 7 2006.92 30 14.75 3015 1334 1.59 / 442.32 2 3
4 13 1670.80 25 14.72 2605 959 2.55 / 443.28 2 5
5 13 935.64 25 14.81 1649 611 3.16 / 443.89 2 5
6 13 200.56 25 15.01 609 229 3.39 / 444.12 2 4
7 8 0.12 165 15.04 299 742 4.13 / 444.86 2 8
Average= 4.16
(KJ/cycle)

Cycle 105 GMT 19/ 6/2021 15:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 31 15.02 446 208 0.21 / 436.69 2 2
2 12 1172.72 2 15.16 2015 61 0.27 / 436.75 2 3
3 7 2004.16 30 14.75 3012 1333 1.60 / 438.08 3 3
4 13 1692.00 25 14.71 2634 969 2.57 / 439.05 2 5
5 13 795.52 25 14.85 1465 544 3.11 / 439.59 2 5
6 13 237.28 25 15.01 667 250 3.36 / 439.84 2 4
7 13 44.84 25 15.06 366 138 3.50 / 439.98 2 4
8 8 0.04 165 15.03 301 746 4.25 / 440.73 2 10
Average= 4.16
(KJ/cycle)

Cycle 104 GMT 9/ 6/2021 17:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 31 15.02 428 199 0.20 / 432.69 2 2
2 12 1165.08 2 15.16 2042 62 0.26 / 432.75 2 2
3 7 2007.40 30 14.76 3020 1337 1.60 / 434.09 2 4
4 13 1530.84 25 14.74 2426 894 2.49 / 434.98 2 5
5 13 830.48 25 14.84 1512 561 3.05 / 435.54 2 5
6 13 157.12 25 15.04 534 201 3.25 / 435.74 2 3
7 8 0.16 165 15.05 296 735 3.99 / 436.48 2 8
Average= 4.16
(KJ/cycle)

Cycle 103 GMT 30/ 5/2021 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 15.01 438 204 0.20 / 428.66 2 2
2 12 1173.44 2 15.16 2036 62 0.27 / 428.73 2 2
3 7 2003.88 30 14.77 3017 1337 1.60 / 430.06 2 3
4 13 1554.60 25 14.74 2462 907 2.51 / 430.97 2 3
5 13 863.76 25 14.84 1556 577 3.09 / 431.55 2 4
6 13 181.32 25 15.03 574 216 3.30 / 431.76 2 3
7 8 0.16 165 15.05 292 725 4.03 / 432.49 2 9
Average= 4.16
(KJ/cycle)

Cycle 102 GMT 20/ 5/2021 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 31 15.01 449 209 0.21 / 424.29 2 2
2 12 1169.08 2 15.16 2026 61 0.27 / 424.35 2 2
3 7 2010.28 30 14.77 3036 1345 1.62 / 425.70 2 3
4 13 1860.84 25 14.69 2847 1046 2.66 / 426.74 2 6
5 13 930.40 25 14.82 1642 608 3.27 / 427.35 2 4
6 13 219.04 25 15.02 638 240 3.51 / 427.59 2 4
7 13 44.44 25 15.06 370 139 3.65 / 427.73 2 4
8 8 0.12 165 15.04 295 732 4.38 / 428.46 2 7
Average= 4.16
(KJ/cycle)

Cycle 101 GMT 11/ 5/2021 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 31 15.02 435 203 0.20 / 420.01 2 2
2 12 1168.40 2 15.16 2036 62 0.26 / 420.08 2 2
3 7 2003.04 30 14.76 3013 1334 1.60 / 421.41 2 3
4 13 1670.80 25 14.72 2601 957 2.56 / 422.37 2 3
5 13 923.44 25 14.82 1634 605 3.16 / 422.97 2 4
6 13 198.08 25 15.03 609 229 3.39 / 423.20 2 4
7 13 41.24 25 15.06 366 138 3.53 / 423.34 2 4
8 8 0.08 165 15.04 299 742 4.27 / 424.08 2 10
Average= 4.16
(KJ/cycle)

Cycle 100 GMT 1/ 5/2021 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 31 15.00 434 202 0.20 / 415.92 2 2
2 12 1165.08 2 15.18 2036 62 0.26 / 415.98 2 2
3 7 2006.84 31 14.78 3019 1383 1.65 / 417.37 2 3
4 13 1682.16 25 14.74 2620 965 2.61 / 418.33 2 4
5 13 807.28 25 14.87 1475 548 3.16 / 418.88 2 5
6 13 148.88 25 15.04 525 197 3.36 / 419.08 2 3
7 8 0.16 165 15.05 295 733 4.09 / 419.81 2 9
Average= 4.16
(KJ/cycle)

Cycle 99 GMT 21/ 4/2021 4:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 31 15.00 439 204 0.20 / 411.75 2 2
2 12 1171.84 2 15.18 2019 61 0.27 / 411.81 2 2
3 7 2006.40 30 14.79 3010 1336 1.60 / 413.14 2 3
4 13 1679.52 25 14.75 2617 965 2.57 / 414.11 2 5
5 13 802.92 25 14.86 1472 547 3.11 / 414.65 2 5
6 13 158.84 25 15.04 540 203 3.32 / 414.86 2 3
7 13 35.88 25 15.07 353 133 3.45 / 414.99 2 4
8 8 0.12 165 15.04 294 730 4.18 / 415.72 2 8
Average= 4.16
(KJ/cycle)

Cycle 98 GMT 11/ 4/2021 6:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 31 15.00 448 208 0.21 / 407.39 2 2
2 12 1175.32 2 15.18 2026 62 0.27 / 407.45 2 2
3 7 2005.92 31 14.78 3017 1382 1.65 / 408.84 2 3
4 13 1701.60 25 14.74 2648 976 2.63 / 409.81 2 5
5 13 951.08 25 14.83 1674 621 3.25 / 410.43 2 4
6 13 208.72 25 15.02 626 235 3.48 / 410.67 2 4
7 13 40.72 25 15.06 363 137 3.62 / 410.80 2 4
8 8 0.16 165 15.04 297 737 4.36 / 411.54 2 12
Average= 4.16
(KJ/cycle)

Cycle 97 GMT 1/ 4/2021 8:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 31 15.00 441 205 0.21 / 403.07 2 2
2 12 1176.48 2 15.18 2017 61 0.27 / 403.13 2 2
3 7 2007.40 30 14.79 3012 1336 1.60 / 404.47 2 3
4 13 1688.32 25 14.74 2627 968 2.57 / 405.44 2 5
5 13 948.64 25 14.84 1666 618 3.19 / 406.05 2 4
6 13 214.68 25 15.02 636 239 3.43 / 406.29 2 4
7 13 44.88 25 15.06 378 142 3.57 / 406.44 2 4
8 8 0.12 165 15.04 302 749 4.32 / 407.18 2 10
Average= 4.15
(KJ/cycle)

Cycle 96 GMT 22/ 3/2021 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 15.02 441 205 0.21 / 398.76 2 2
2 12 1175.72 2 15.19 2021 61 0.27 / 398.82 2 2
3 7 2008.32 30 14.78 3029 1343 1.61 / 400.17 2 3
4 13 1688.72 25 14.75 2629 969 2.58 / 401.13 2 5
5 13 945.08 25 14.83 1663 617 3.20 / 401.75 2 4
6 13 207.36 25 15.02 620 233 3.43 / 401.98 2 4
7 13 41.60 25 15.06 370 139 3.57 / 402.12 2 4
8 8 0.08 165 15.04 299 742 4.31 / 402.87 2 8
Average= 4.15
(KJ/cycle)

Cycle 95 GMT 12/ 3/2021 13:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 31 15.00 443 206 0.21 / 394.61 2 2
2 12 1179.60 2 15.18 2043 62 0.27 / 394.67 2 2
3 7 2002.48 30 14.79 3019 1340 1.61 / 396.01 2 3
4 13 1531.32 25 14.77 2439 901 2.51 / 396.91 2 6
5 13 843.24 25 14.86 1534 570 3.08 / 397.48 2 5
6 13 178.80 25 15.04 575 216 3.29 / 397.70 2 3
7 13 23.52 25 15.08 332 125 3.42 / 397.83 2 4
8 8 0.08 165 15.05 294 730 4.15 / 398.56 2 10
Average= 4.15
(KJ/cycle)

Cycle 94 GMT 2/ 3/2021 15:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 31 15.01 454 211 0.21 / 390.35 2 2
2 12 1185.76 2 15.20 2033 62 0.27 / 390.42 2 2
3 7 2005.20 30 14.78 3026 1342 1.61 / 391.76 2 3
4 13 1683.60 25 14.75 2625 968 2.58 / 392.73 2 7
5 13 786.96 25 14.88 1451 540 3.12 / 393.27 2 5
6 13 235.76 25 15.01 668 251 3.37 / 393.52 2 4
7 13 41.92 25 15.07 372 140 3.51 / 393.66 2 4
8 8 0.16 165 15.04 302 749 4.26 / 394.41 2 9
Average= 4.15
(KJ/cycle)

Cycle 93 GMT 20/ 2/2021 17:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 15.02 441 205 0.21 / 386.05 2 2
2 12 1170.00 2 15.19 2021 61 0.27 / 386.11 2 2
3 7 2004.84 30 14.78 3031 1344 1.61 / 387.46 2 3
4 13 1685.16 25 14.74 2629 969 2.58 / 388.43 2 4
5 13 929.60 25 14.84 1648 611 3.19 / 389.04 2 5
6 13 200.20 25 15.03 610 229 3.42 / 389.27 2 4
7 13 40.92 25 15.07 363 137 3.56 / 389.40 2 4
8 8 0.08 165 15.04 298 740 4.30 / 390.14 2 9
Average= 4.15
(KJ/cycle)

Cycle 92 GMT 10/ 2/2021 19:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 31 15.02 447 208 0.21 / 381.91 2 2
2 12 1152.08 2 15.18 2005 61 0.27 / 381.97 2 2
3 7 2003.52 30 14.77 3016 1336 1.61 / 383.31 2 3
4 13 1530.84 25 14.77 2431 898 2.50 / 384.21 2 4
5 13 830.20 25 14.86 1510 561 3.06 / 384.77 2 5
6 13 161.60 25 15.05 546 205 3.27 / 384.97 2 3
7 13 35.00 25 15.08 356 134 3.40 / 385.11 2 4
8 8 0.08 165 15.05 298 740 4.14 / 385.85 2 9
Average= 4.15
(KJ/cycle)

Cycle 91 GMT 31/ 1/2021 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 31 15.02 438 204 0.20 / 377.61 2 2
2 12 1192.96 2 15.17 2084 63 0.27 / 377.67 2 2
3 7 2004.96 30 14.78 3026 1342 1.61 / 379.02 2 3
4 13 1680.52 25 14.74 2627 968 2.58 / 379.98 2 5
5 13 926.88 25 14.84 1642 609 3.19 / 380.59 2 4
6 13 197.20 25 15.04 607 228 3.41 / 380.82 2 3
7 13 48.04 25 15.07 378 142 3.56 / 380.96 2 4
8 8 0.16 165 15.05 298 740 4.30 / 381.70 2 8
Average= 4.15
(KJ/cycle)

Cycle 90 GMT 22/ 1/2021 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 31 15.02 435 203 0.20 / 373.37 2 2
2 12 1168.96 2 15.18 2044 62 0.26 / 373.43 2 2
3 7 2003.36 30 14.78 3018 1338 1.60 / 374.77 2 3
4 13 1529.16 25 14.77 2427 896 2.50 / 375.67 2 5
5 13 966.00 25 14.84 1690 627 3.13 / 376.29 2 4
6 13 206.04 25 15.03 620 233 3.36 / 376.53 2 4
7 13 41.12 25 15.07 368 139 3.50 / 376.66 2 4
8 8 0.08 165 15.05 299 742 4.24 / 377.41 2 9
Average= 4.15
(KJ/cycle)

Cycle 89 GMT 12/ 1/2021 2:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 31 15.01 445 207 0.21 / 369.13 2 2
2 12 1173.72 2 15.19 2057 62 0.27 / 369.19 2 2
3 7 2003.28 30 14.79 3015 1338 1.61 / 370.53 2 3
4 13 1516.28 25 14.78 2418 893 2.50 / 371.42 2 5
5 13 959.88 25 14.84 1693 628 3.13 / 372.05 2 5
6 13 218.44 25 15.03 640 240 3.37 / 372.29 2 4
7 13 18.92 25 15.08 339 128 3.50 / 372.42 2 4
8 8 0.00 165 15.05 300 745 4.24 / 373.17 2 8
Average= 4.15
(KJ/cycle)

Cycle 88 GMT 2/ 1/2021 4:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 31 15.02 445 207 0.21 / 364.88 2 2
2 12 1177.80 2 15.18 2067 63 0.27 / 364.94 2 2
3 7 2004.32 30 14.78 3030 1344 1.61 / 366.28 2 3
4 13 1682.28 25 14.75 2622 967 2.58 / 367.25 2 4
5 13 798.12 25 14.88 1472 548 3.13 / 367.80 2 5
6 13 241.64 25 15.02 680 255 3.38 / 368.05 2 4
7 13 21.36 25 15.08 339 128 3.51 / 368.18 2 4
8 8 0.12 165 15.05 300 745 4.26 / 368.92 2 7
Average= 4.15
(KJ/cycle)

Cycle 87 GMT 23/12/2020 6:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 15.03 434 202 0.20 / 360.73 2 2
2 12 1169.36 2 15.18 2038 62 0.26 / 360.79 2 2
3 7 2003.24 30 14.78 3036 1346 1.61 / 362.14 2 3
4 13 1534.48 25 14.78 2440 902 2.51 / 363.04 2 4
5 13 846.60 25 14.86 1536 571 3.08 / 363.61 2 4
6 13 162.00 25 15.05 546 205 3.29 / 363.81 2 3
7 13 19.08 25 15.09 332 125 3.41 / 363.94 2 4
8 8 0.04 165 15.06 293 728 4.14 / 364.67 2 10
Average= 4.14
(KJ/cycle)

Cycle 86 GMT 13/12/2020 8:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 31 15.03 445 207 0.21 / 356.60 2 2
2 12 1181.12 2 15.19 2046 62 0.27 / 356.66 2 2
3 7 2002.28 30 14.79 3022 1341 1.61 / 358.00 2 3
4 13 1520.64 25 14.78 2426 896 2.51 / 358.90 2 4
5 13 828.84 25 14.87 1517 564 3.07 / 359.46 2 5
6 13 153.36 25 15.06 535 201 3.27 / 359.66 2 3
7 13 34.28 25 15.09 357 135 3.41 / 359.80 2 4
8 8 0.20 165 15.06 294 731 4.14 / 360.53 2 9
Average= 4.14
(KJ/cycle)

Cycle 85 GMT 3/12/2020 10:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 31 15.04 443 207 0.21 / 352.29 2 2
2 12 1323.56 2 15.14 2277 69 0.28 / 352.35 2 2
3 7 2006.60 30 14.80 3031 1346 1.62 / 353.70 2 4
4 13 1686.20 25 14.76 2627 969 2.59 / 354.67 2 3
5 13 943.08 25 14.85 1665 618 3.21 / 355.29 2 5
6 13 207.28 25 15.04 623 234 3.44 / 355.52 2 4
7 13 23.16 25 15.09 343 129 3.57 / 355.65 2 4
8 8 0.08 165 15.06 297 738 4.31 / 356.39 2 10
Average= 4.14
(KJ/cycle)

Cycle 84 GMT 23/11/2020 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 31 15.05 442 206 0.21 / 348.26 2 2
2 12 1189.80 2 15.19 2061 63 0.27 / 348.32 2 2
3 7 2002.44 30 14.81 3021 1342 1.61 / 349.67 2 3
4 13 1528.08 25 14.79 2429 898 2.51 / 350.56 2 5
5 13 829.32 25 14.88 1515 564 3.07 / 351.13 2 5
6 13 154.36 25 15.07 541 204 3.28 / 351.33 2 4
7 8 0.08 165 15.07 301 748 4.03 / 352.08 2 7
Average= 4.14
(KJ/cycle)

Cycle 83 GMT 13/11/2020 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 31 15.05 441 206 0.21 / 344.26 2 2
2 12 1160.68 2 15.21 2020 61 0.27 / 344.33 2 2
3 7 2003.04 30 14.79 3012 1336 1.60 / 345.66 2 4
4 13 1523.92 25 14.78 2425 896 2.50 / 346.56 2 4
5 13 815.28 25 14.89 1497 557 3.06 / 347.12 2 5
6 13 154.64 25 15.07 536 202 3.26 / 347.32 2 4
7 8 0.24 165 15.08 296 737 4.00 / 348.05 2 8
Average= 4.14
(KJ/cycle)

Cycle 82 GMT 3/11/2020 16:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 31 15.03 448 209 0.21 / 340.15 2 2
2 12 1169.80 2 15.21 2031 62 0.27 / 340.21 2 2
3 7 2004.56 30 14.80 3032 1346 1.62 / 341.56 2 4
4 13 1679.20 25 14.76 2621 967 2.58 / 342.53 2 5
5 13 788.96 25 14.90 1456 542 3.13 / 343.07 2 5
6 13 234.28 25 15.04 665 250 3.38 / 343.32 2 4
7 8 0.20 165 15.08 297 739 4.12 / 344.06 2 7
Average= 4.15
(KJ/cycle)

Cycle 81 GMT 24/10/2020 18:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 31 15.05 440 205 0.21 / 335.79 2 2
2 12 1176.44 2 15.19 2032 62 0.27 / 335.86 2 2
3 7 2006.04 30 14.81 3023 1343 1.61 / 337.20 2 3
4 13 1686.72 25 14.77 2634 973 2.58 / 338.17 2 5
5 13 960.48 25 14.86 1691 628 3.21 / 338.80 2 4
6 13 217.88 25 15.05 648 244 3.45 / 339.04 2 4
7 13 20.44 25 15.10 347 131 3.59 / 339.17 2 4
8 8 0.08 165 15.07 309 768 4.35 / 339.94 2 10
Average= 4.15
(KJ/cycle)

Cycle 80 GMT 14/10/2020 21: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 31 15.06 454 212 0.21 / 331.63 2 2
2 12 1173.16 2 15.21 2020 61 0.27 / 331.69 2 2
3 7 2004.84 30 14.80 3018 1340 1.61 / 333.03 2 3
4 13 1673.84 25 14.77 2618 967 2.58 / 333.99 2 4
5 13 946.16 25 14.87 1667 620 3.20 / 334.61 2 5
6 13 198.12 25 15.06 612 230 3.43 / 334.84 2 4
7 8 0.20 165 15.09 299 744 4.17 / 335.59 2 8
Average= 4.14
(KJ/cycle)

Cycle 79 GMT 4/10/2020 23:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 31 15.06 445 208 0.21 / 327.46 2 2
2 12 1168.68 2 15.22 2007 61 0.27 / 327.52 2 2
3 7 2002.44 30 14.80 3019 1340 1.61 / 328.86 2 3
4 13 1679.32 25 14.78 2625 970 2.58 / 329.83 2 3
5 13 927.56 25 14.87 1643 611 3.19 / 330.44 2 5
6 13 203.56 25 15.06 619 233 3.42 / 330.67 2 4
7 8 0.08 165 15.09 298 742 4.17 / 331.41 2 9
Average= 4.14
(KJ/cycle)

Cycle 78 GMT 25/ 9/2020 1:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 31 15.05 452 211 0.21 / 323.39 2 2
2 12 1158.60 2 15.21 2020 61 0.27 / 323.45 2 2
3 7 2005.40 31 14.81 3029 1391 1.66 / 324.84 2 3
4 13 1537.28 25 14.80 2442 904 2.57 / 325.74 2 5
5 13 820.36 25 14.90 1500 559 3.13 / 326.30 2 4
6 13 166.16 25 15.08 554 209 3.33 / 326.51 2 3
7 8 0.08 165 15.10 296 737 4.07 / 327.25 2 7
Average= 4.14
(KJ/cycle)

Cycle 77 GMT 15/ 9/2020 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 31 15.06 446 208 0.21 / 319.06 2 2
2 12 1330.08 2 15.17 2225 68 0.28 / 319.13 2 2
3 7 2002.64 30 14.82 3024 1344 1.62 / 320.47 2 3
4 13 1681.80 25 14.78 2628 971 2.59 / 321.44 2 5
5 13 935.92 25 14.88 1659 617 3.21 / 322.06 2 4
6 13 201.56 25 15.08 619 233 3.44 / 322.30 2 4
7 13 21.28 25 15.12 339 128 3.57 / 322.42 2 4
8 8 0.08 165 15.09 303 754 4.32 / 323.18 2 7
Average= 4.14
(KJ/cycle)

Cycle 76 GMT 5/ 9/2020 5:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 31 15.09 446 209 0.21 / 314.85 2 2
2 12 1180.88 2 15.22 2043 62 0.27 / 314.91 2 2
3 7 2004.36 30 14.81 3016 1340 1.61 / 316.25 2 4
4 13 1673.68 25 14.78 2621 968 2.58 / 317.22 2 4
5 13 814.36 25 14.91 1493 557 3.14 / 317.78 2 5
6 13 160.96 25 15.10 556 210 3.35 / 317.99 2 3
7 13 18.32 25 15.13 331 125 3.47 / 318.11 2 4
8 8 0.12 165 15.10 297 740 4.21 / 318.85 2 7
Average= 4.14
(KJ/cycle)

Cycle 75 GMT 26/ 8/2020 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 31 15.09 444 208 0.21 / 310.75 2 2
2 12 1170.56 2 15.22 2040 62 0.27 / 310.81 2 3
3 7 2002.92 30 14.81 3037 1349 1.62 / 312.16 3 3
4 13 1689.04 25 14.78 2644 977 2.60 / 313.13 2 5
5 13 800.16 25 14.92 1482 553 3.15 / 313.69 2 5
6 13 152.28 25 15.10 549 207 3.36 / 313.89 2 4
7 8 0.12 165 15.12 300 748 4.10 / 314.64 2 9
Average= 4.14
(KJ/cycle)

Cycle 74 GMT 16/ 8/2020 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 31 15.08 441 206 0.21 / 306.72 2 2
2 12 1165.44 2 15.23 2028 62 0.27 / 306.78 2 2
3 7 2005.08 30 14.82 3027 1346 1.61 / 308.12 2 3
4 13 1510.68 25 14.81 2418 895 2.51 / 309.02 2 5
5 13 816.80 25 14.92 1502 560 3.07 / 309.58 2 6
6 13 148.96 25 15.11 540 204 3.27 / 309.78 2 3
7 8 0.12 165 15.12 303 756 4.03 / 310.54 2 9
Average= 4.14
(KJ/cycle)

Cycle 73 GMT 6/ 8/2020 11:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 31 15.09 449 210 0.21 / 302.50 2 2
2 12 1171.96 2 15.22 2037 62 0.27 / 302.57 2 2
3 7 2007.76 30 14.83 3025 1346 1.62 / 303.91 2 3
4 13 1551.64 25 14.81 2470 915 2.53 / 304.83 2 3
5 13 870.96 25 14.91 1572 586 3.12 / 305.41 2 5
6 13 171.60 25 15.11 572 216 3.33 / 305.63 2 4
7 13 18.28 25 15.15 336 127 3.46 / 305.76 2 4
8 8 0.08 165 15.11 302 753 4.21 / 306.51 2 10
Average= 4.14
(KJ/cycle)

Cycle 72 GMT 27/ 7/2020 13:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 15.10 452 212 0.21 / 298.45 2 2
2 12 1164.20 2 15.23 2037 62 0.27 / 298.52 2 3
3 7 2008.52 30 14.82 3041 1352 1.63 / 299.87 3 3
4 13 1520.92 25 14.82 2430 900 2.53 / 300.77 2 4
5 13 827.12 25 14.92 1519 567 3.09 / 301.33 2 4
6 13 152.68 25 15.12 545 206 3.30 / 301.54 2 4
7 8 0.12 165 15.13 302 754 4.05 / 302.29 2 8
Average= 4.14
(KJ/cycle)

Cycle 71 GMT 17/ 7/2020 15:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 31 15.10 452 212 0.21 / 294.29 2 2
2 12 1174.28 2 15.23 2055 63 0.27 / 294.36 2 2
3 7 2005.44 31 14.82 3034 1394 1.67 / 295.75 2 3
4 13 1682.96 25 14.79 2635 974 2.64 / 296.72 2 6
5 13 801.24 25 14.94 1484 554 3.20 / 297.28 2 5
6 13 149.08 25 15.13 540 204 3.40 / 297.48 2 3
7 8 0.20 165 15.14 304 759 4.16 / 298.24 2 10
Average= 4.14
(KJ/cycle)

Cycle 70 GMT 7/ 7/2020 17:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 31 15.11 447 209 0.21 / 290.05 2 2
2 12 1155.80 2 15.24 2029 62 0.27 / 290.12 2 2
3 7 2003.68 30 14.84 3033 1350 1.62 / 291.47 2 3
4 13 1534.12 25 14.82 2454 909 2.53 / 292.38 2 3
5 13 858.32 25 14.92 1563 583 3.11 / 292.96 2 4
6 13 168.16 25 15.13 573 217 3.33 / 293.18 2 4
7 13 41.32 25 15.15 375 142 3.47 / 293.32 2 4
8 8 0.12 165 15.13 306 764 4.24 / 294.08 2 8
Average= 4.14
(KJ/cycle)

Cycle 69 GMT 27/ 6/2020 19: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 31 15.11 446 209 0.21 / 285.96 2 2
2 12 1203.68 2 15.22 2070 63 0.27 / 286.02 2 2
3 7 2004.00 31 14.83 3025 1391 1.66 / 287.42 2 5
4 13 1516.80 25 14.82 2431 901 2.56 / 288.32 2 3
5 13 813.72 25 14.94 1499 560 3.12 / 288.88 2 4
6 13 157.32 25 15.14 553 209 3.33 / 289.09 2 3
7 8 0.16 165 15.15 304 760 4.09 / 289.85 2 6
Average= 4.14
(KJ/cycle)

Cycle 68 GMT 17/ 6/2020 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 31 15.11 446 209 0.21 / 281.58 2 2
2 12 1176.52 2 15.24 2036 62 0.27 / 281.64 2 3
3 7 2004.08 31 14.83 3030 1393 1.66 / 283.03 3 3
4 13 1676.60 25 14.79 2620 969 2.63 / 284.00 2 4
5 13 924.48 25 14.92 1646 614 3.25 / 284.62 2 5
6 13 189.64 25 15.13 607 230 3.48 / 284.85 2 4
7 13 41.20 25 15.17 376 143 3.62 / 284.99 2 4
8 8 0.12 165 15.14 306 764 4.38 / 285.75 2 10
Average= 4.14
(KJ/cycle)

Cycle 67 GMT 7/ 6/2020 23: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 31 15.13 447 210 0.21 / 277.31 2 2
2 12 1189.32 2 15.23 2064 63 0.27 / 277.37 2 2
3 7 2003.00 30 14.84 3021 1345 1.62 / 278.72 2 3
4 13 1672.60 25 14.81 2630 974 2.59 / 279.69 2 3
5 13 755.04 25 14.97 1414 529 3.12 / 280.22 2 4
6 13 214.84 25 15.13 642 243 3.36 / 280.47 2 4
7 13 47.12 25 15.17 386 146 3.51 / 280.61 2 4
8 8 0.04 165 15.15 303 757 4.27 / 281.37 2 9
Average= 4.14
(KJ/cycle)

Cycle 66 GMT 29/ 5/2020 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 31 15.12 458 215 0.21 / 273.09 2 2
2 12 1168.56 2 15.25 2039 62 0.28 / 273.15 2 2
3 7 2001.92 30 14.85 3030 1350 1.63 / 274.50 2 3
4 13 1542.64 25 14.83 2459 912 2.54 / 275.41 2 4
5 13 852.00 25 14.94 1551 579 3.12 / 275.99 2 4
6 13 169.04 25 15.15 563 213 3.33 / 276.21 2 4
7 13 46.92 25 15.18 375 142 3.47 / 276.35 2 4
8 8 0.12 165 15.15 302 755 4.23 / 277.10 2 8
Average= 4.14
(KJ/cycle)

Cycle 65 GMT 19/ 5/2020 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 31 15.12 466 218 0.22 / 268.71 2 2
2 12 1167.36 2 15.25 2035 62 0.28 / 268.77 2 2
3 7 2004.68 30 14.84 3016 1343 1.62 / 270.11 2 3
4 13 1696.12 25 14.80 2653 982 2.60 / 271.09 2 5
5 13 947.00 25 14.92 1672 624 3.23 / 271.72 2 4
6 13 202.56 25 15.14 625 237 3.47 / 271.95 2 4
7 13 46.72 25 15.18 389 148 3.61 / 272.10 2 4
8 8 0.04 165 15.16 309 773 4.39 / 272.87 2 10
Average= 4.13
(KJ/cycle)

Cycle 64 GMT 9/ 5/2020 5:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 31 15.14 450 211 0.21 / 264.33 2 2
2 12 1172.00 2 15.24 2047 62 0.27 / 264.40 2 2
3 7 2007.76 31 14.84 3030 1394 1.67 / 265.79 2 3
4 13 1684.16 25 14.81 2627 973 2.64 / 266.76 2 4
5 13 790.44 25 14.97 1467 549 3.19 / 267.31 2 5
6 13 237.88 25 15.13 677 256 3.45 / 267.57 2 4
7 13 46.20 25 15.18 385 146 3.59 / 267.71 2 4
8 8 0.04 165 15.16 310 775 4.37 / 268.49 2 11
Average= 4.13
(KJ/cycle)

Cycle 63 GMT 29/ 4/2020 7:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 15.15 448 210 0.21 / 260.14 2 2
2 12 1172.04 2 15.24 2044 62 0.27 / 260.20 2 2
3 7 2003.36 30 14.84 3034 1351 1.62 / 261.55 2 4
4 13 1515.88 25 14.84 2420 898 2.52 / 262.45 2 5
5 13 818.32 25 14.97 1507 564 3.09 / 263.02 2 4
6 13 155.92 25 15.17 547 207 3.29 / 263.22 2 3
7 13 41.08 25 15.19 374 142 3.43 / 263.37 2 4
8 8 0.00 165 15.17 302 756 4.19 / 264.12 2 8
Average= 4.13
(KJ/cycle)

Cycle 62 GMT 19/ 4/2020 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 30 15.14 460 209 0.21 / 255.90 2 2
2 12 1186.48 2 15.25 2084 64 0.27 / 255.96 2 2
3 7 2011.04 30 14.85 3043 1356 1.63 / 257.32 2 3
4 13 1549.80 25 14.84 2467 915 2.54 / 258.23 2 4
5 13 860.52 25 14.96 1559 583 3.13 / 258.81 2 4
6 13 173.56 25 15.17 578 219 3.35 / 259.03 2 4
7 13 46.96 25 15.20 380 144 3.49 / 259.18 2 4
8 8 0.16 165 15.18 301 754 4.24 / 259.93 2 11
Average= 4.13
(KJ/cycle)

Cycle 61 GMT 9/ 4/2020 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 30 15.15 451 205 0.20 / 251.54 2 2
2 12 1181.68 2 15.25 2051 63 0.27 / 251.60 2 2
3 7 2004.76 30 14.86 3033 1352 1.62 / 252.95 2 3
4 13 1691.52 25 14.83 2645 981 2.60 / 253.93 2 4
5 13 813.76 25 14.98 1498 561 3.16 / 254.49 2 5
6 13 258.76 25 15.14 718 272 3.43 / 254.76 2 4
7 13 56.96 25 15.20 400 152 3.59 / 254.92 2 4
8 8 0.16 165 15.17 308 771 4.36 / 255.69 2 10
Average= 4.12
(KJ/cycle)

Cycle 60 GMT 30/ 3/2020 13:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 30 15.16 444 202 0.20 / 247.29 2 2
2 12 1181.36 2 15.25 2037 62 0.26 / 247.36 2 2
3 7 2001.72 30 14.85 3035 1352 1.62 / 248.71 2 3
4 13 1522.48 25 14.86 2430 903 2.52 / 249.61 2 3
5 13 793.96 25 14.99 1469 551 3.07 / 250.16 2 5
6 13 244.20 25 15.15 686 260 3.33 / 250.42 2 4
7 13 51.88 25 15.20 390 148 3.48 / 250.57 2 4
8 8 0.08 165 15.18 304 761 4.24 / 251.33 2 8
Average= 4.12
(KJ/cycle)

Cycle 59 GMT 20/ 3/2020 15:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 15.16 445 202 0.20 / 243.09 2 2
2 12 1178.96 2 15.25 2054 63 0.27 / 243.15 2 3
3 7 2003.68 30 14.87 3039 1356 1.62 / 244.50 3 3
4 13 1543.92 25 14.85 2454 911 2.53 / 245.41 2 4
5 13 841.88 25 14.98 1538 576 3.11 / 245.99 2 5
6 13 171.32 25 15.18 570 216 3.32 / 246.21 2 4
7 13 47.48 25 15.21 378 144 3.47 / 246.35 2 4
8 8 0.20 165 15.19 296 742 4.21 / 247.09 2 9
Average= 4.12
(KJ/cycle)

Cycle 58 GMT 10/ 3/2020 17:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 30 15.16 462 210 0.21 / 238.89 2 2
2 12 1179.76 2 15.26 2066 63 0.27 / 238.96 2 2
3 7 2002.40 30 14.86 3026 1349 1.62 / 240.31 2 3
4 13 1528.84 25 14.85 2437 905 2.53 / 241.21 2 4
5 13 814.76 25 14.99 1501 562 3.09 / 241.77 2 5
6 13 157.00 25 15.19 554 210 3.30 / 241.98 2 4
7 13 37.56 25 15.22 374 142 3.44 / 242.13 2 4
8 8 0.16 165 15.19 302 757 4.20 / 242.88 2 9
Average= 4.12
(KJ/cycle)

Cycle 57 GMT 29/ 2/2020 19:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 30 15.17 441 201 0.20 / 234.58 2 2
2 12 1171.80 2 15.26 2041 62 0.26 / 234.64 2 2
3 7 2003.68 30 14.86 3038 1354 1.62 / 236.00 2 5
4 13 1662.76 25 14.83 2615 970 2.59 / 236.97 2 6
5 13 764.48 25 15.01 1437 539 3.13 / 237.51 2 6
6 13 224.80 25 15.17 663 251 3.38 / 237.76 2 4
7 13 43.44 25 15.21 388 148 3.53 / 237.90 2 4
8 8 0.16 165 15.19 311 779 4.30 / 238.68 2 10
Average= 4.12
(KJ/cycle)

Cycle 56 GMT 19/ 2/2020 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 15.18 440 200 0.20 / 230.29 2 2
2 12 1178.96 2 15.26 2058 63 0.26 / 230.35 2 2
3 7 2003.16 30 14.85 3027 1349 1.61 / 231.70 2 3
4 13 1670.60 25 14.83 2613 969 2.58 / 232.67 2 4
5 13 782.24 25 15.01 1462 549 3.13 / 233.22 2 5
6 13 229.24 25 15.17 673 255 3.38 / 233.47 2 5
7 13 44.84 25 15.22 382 145 3.53 / 233.62 2 4
8 8 0.16 165 15.20 304 762 4.29 / 234.38 2 8
Average= 4.11
(KJ/cycle)

Cycle 55 GMT 9/ 2/2020 23:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 30 15.18 453 206 0.21 / 226.11 2 2
2 12 1162.92 2 15.26 2034 62 0.27 / 226.18 2 2
3 7 2005.16 30 14.85 3039 1354 1.62 / 227.53 2 3
4 13 1515.08 25 14.87 2428 903 2.52 / 228.43 2 4
5 13 810.32 25 15.00 1498 562 3.09 / 228.99 2 5
6 13 152.16 25 15.21 539 205 3.29 / 229.20 2 3
7 13 36.40 25 15.23 363 138 3.43 / 229.34 2 4
8 8 0.28 165 15.20 299 750 4.18 / 230.09 2 9
Average= 4.11
(KJ/cycle)

Cycle 54 GMT 31/ 1/2020 1:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 15.18 447 204 0.20 / 221.91 2 2
2 12 1170.08 2 15.27 2032 62 0.27 / 221.97 2 2
3 7 2007.92 30 14.85 3036 1353 1.62 / 223.32 2 3
4 13 1526.60 25 14.86 2441 907 2.52 / 224.23 2 4
5 13 821.12 25 15.00 1511 567 3.09 / 224.80 2 6
6 13 161.16 25 15.21 556 211 3.30 / 225.01 2 3
7 13 39.60 25 15.23 369 140 3.44 / 225.15 2 4
8 8 0.16 165 15.21 303 760 4.20 / 225.91 2 10
Average= 4.11
(KJ/cycle)

Cycle 53 GMT 21/ 1/2020 3: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 15.18 447 204 0.20 / 217.67 2 2
2 12 1171.32 2 15.28 2030 62 0.27 / 217.74 2 2
3 7 2005.12 31 14.87 3027 1395 1.66 / 219.13 2 5
4 13 1513.52 25 14.88 2425 902 2.56 / 220.03 2 4
5 13 819.80 25 15.01 1507 566 3.13 / 220.60 2 5
6 13 145.56 25 15.21 536 204 3.33 / 220.80 2 3
7 13 31.48 25 15.24 362 138 3.47 / 220.94 2 4
8 8 0.08 165 15.21 304 763 4.23 / 221.70 2 10
Average= 4.11
(KJ/cycle)

Cycle 52 GMT 11/ 1/2020 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 30 15.18 449 204 0.20 / 213.46 2 2
2 12 1167.52 2 15.28 2034 62 0.27 / 213.52 2 2
3 7 2006.88 30 14.88 3023 1349 1.62 / 214.87 2 5
4 13 1525.84 25 14.87 2448 910 2.53 / 215.78 2 5
5 13 816.84 25 15.02 1515 569 3.10 / 216.35 2 4
6 13 155.72 25 15.22 554 211 3.31 / 216.56 2 3
7 13 34.04 25 15.24 363 138 3.44 / 216.70 2 4
8 8 -0.08 165 15.22 306 768 4.21 / 217.47 2 7
Average= 4.10
(KJ/cycle)

Cycle 51 GMT 1/ 1/2020 6:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 30 15.18 446 203 0.20 / 209.24 2 2
2 12 1169.24 2 15.28 2064 63 0.27 / 209.30 2 2
3 7 2005.88 30 14.89 3035 1356 1.62 / 210.66 2 4
4 13 1518.36 25 14.88 2433 905 2.53 / 211.56 2 4
5 13 829.00 25 15.01 1519 570 3.10 / 212.13 2 4
6 13 161.24 25 15.22 567 216 3.31 / 212.35 2 3
7 13 16.76 25 15.25 345 132 3.44 / 212.48 2 4
8 8 0.12 165 15.22 309 776 4.22 / 213.26 2 7
Average= 4.10
(KJ/cycle)

Cycle 50 GMT 22/12/2019 8:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 30 15.19 451 206 0.21 / 204.98 2 2
2 12 1163.56 2 15.28 2031 62 0.27 / 205.04 2 2
3 7 2003.60 30 14.88 3036 1355 1.62 / 206.40 2 4
4 13 1527.56 25 14.88 2446 910 2.53 / 207.31 2 4
5 13 806.12 25 15.03 1492 561 3.09 / 207.87 2 5
6 13 236.72 25 15.19 678 257 3.35 / 208.13 2 4
7 13 20.88 25 15.25 345 132 3.48 / 208.26 2 4
8 8 0.16 165 15.21 310 778 4.26 / 209.04 2 10
Average= 4.10
(KJ/cycle)

Cycle 49 GMT 12/12/2019 10:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 30 15.20 446 203 0.20 / 200.78 2 2
2 12 1163.88 2 15.29 2044 63 0.27 / 200.85 2 2
3 7 2007.72 30 14.87 3037 1355 1.62 / 202.20 2 4
4 13 1525.04 25 14.88 2439 907 2.53 / 203.11 2 4
5 13 815.72 25 15.02 1501 564 3.09 / 203.67 2 5
6 13 147.56 25 15.23 539 205 3.30 / 203.88 2 4
7 13 33.48 25 15.26 358 137 3.43 / 204.01 2 4
8 8 0.08 165 15.23 304 764 4.20 / 204.78 2 10
Average= 4.10
(KJ/cycle)

Cycle 48 GMT 2/12/2019 12:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 30 15.20 449 205 0.20 / 196.58 2 2
2 12 1179.88 2 15.27 2068 63 0.27 / 196.64 2 2
3 7 2009.20 31 14.87 3043 1403 1.67 / 198.05 2 3
4 13 1534.20 25 14.88 2440 908 2.58 / 198.95 2 4
5 13 670.88 25 15.07 1310 494 3.07 / 199.45 2 6
6 13 168.76 25 15.22 582 221 3.29 / 199.67 2 4
7 13 32.68 25 15.25 366 140 3.43 / 199.81 2 4
8 8 0.16 165 15.23 307 771 4.20 / 200.58 2 10
Average= 4.09
(KJ/cycle)

Cycle 47 GMT 22/11/2019 14:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 30 15.21 459 209 0.21 / 192.39 2 2
2 12 1156.72 2 15.28 2050 63 0.27 / 192.45 2 2
3 7 2002.92 30 14.88 3026 1351 1.62 / 193.80 2 4
4 13 1522.68 25 14.89 2429 904 2.53 / 194.70 2 5
5 13 796.20 25 15.04 1479 556 3.08 / 195.26 2 4
6 13 143.92 25 15.24 546 208 3.29 / 195.47 2 3
7 13 15.36 25 15.27 335 128 3.42 / 195.60 2 4
8 8 -0.04 165 15.23 310 779 4.20 / 196.38 2 10
Average= 4.09
(KJ/cycle)

Cycle 46 GMT 12/11/2019 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 15.21 458 209 0.21 / 188.28 2 2
2 12 1182.72 2 15.28 2084 64 0.27 / 188.34 2 2
3 7 2008.08 30 14.89 3031 1354 1.63 / 189.70 2 4
4 13 1545.92 25 14.89 2466 918 2.54 / 190.61 2 4
5 13 855.36 25 15.02 1559 585 3.13 / 191.20 2 6
6 13 165.08 25 15.23 565 215 3.35 / 191.42 2 4
7 8 0.32 165 15.24 303 762 4.11 / 192.18 2 8
Average= 4.09
(KJ/cycle)

Cycle 45 GMT 2/11/2019 18:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 30 15.21 448 204 0.20 / 184.01 2 2
2 12 1191.12 2 15.28 2084 64 0.27 / 184.07 2 2
3 7 2004.20 30 14.90 3037 1358 1.63 / 185.43 2 4
4 13 1527.24 25 14.90 2436 907 2.53 / 186.34 2 3
5 13 806.56 25 15.05 1486 559 3.09 / 186.90 2 4
6 13 235.00 25 15.21 684 260 3.35 / 187.16 2 4
7 13 24.12 25 15.27 346 132 3.48 / 187.29 2 4
8 8 0.08 165 15.24 311 782 4.27 / 188.07 2 10
Average= 4.09
(KJ/cycle)

Cycle 44 GMT 23/10/2019 20:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 30 15.21 446 204 0.20 / 179.80 2 2
2 12 1177.80 2 15.29 2053 63 0.27 / 179.87 2 3
3 7 2003.20 30 14.90 3026 1353 1.62 / 181.22 3 3
4 13 1523.68 25 14.90 2429 905 2.52 / 182.12 2 5
5 13 838.96 25 15.04 1538 578 3.10 / 182.70 2 5
6 13 151.48 25 15.24 541 206 3.31 / 182.91 2 3
7 13 32.40 25 15.27 356 136 3.44 / 183.04 2 4
8 8 0.04 165 15.24 302 759 4.20 / 183.80 2 8
Average= 4.08
(KJ/cycle)

Cycle 43 GMT 13/10/2019 22: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 30 15.21 447 204 0.20 / 175.57 2 2
2 12 1159.68 2 15.30 2038 62 0.27 / 175.63 2 2
3 7 2003.84 30 14.90 3029 1354 1.62 / 176.99 2 4
4 13 1521.28 25 14.90 2423 903 2.52 / 177.89 2 4
5 13 828.60 25 15.05 1518 571 3.09 / 178.46 2 5
6 13 157.96 25 15.24 572 218 3.31 / 178.68 2 3
7 13 34.40 25 15.27 361 138 3.45 / 178.82 2 4
8 8 0.12 165 15.24 311 782 4.23 / 179.60 2 10
Average= 4.08
(KJ/cycle)

Cycle 42 GMT 3/10/2019 23:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 30 15.23 438 200 0.20 / 171.31 2 2
2 12 1170.20 2 15.29 2058 63 0.26 / 171.37 2 3
3 7 2004.16 30 14.89 3029 1353 1.62 / 172.72 3 3
4 13 1658.44 25 14.88 2604 969 2.58 / 173.69 2 3
5 13 759.72 25 15.07 1429 538 3.12 / 174.23 2 5
6 13 217.40 25 15.23 646 246 3.37 / 174.48 2 4
7 13 18.16 25 15.28 336 128 3.50 / 174.60 2 4
8 8 0.00 165 15.25 304 765 4.26 / 175.37 2 11
Average= 4.08
(KJ/cycle)

Cycle 41 GMT 24/ 9/2019 1:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 30 15.23 449 205 0.21 / 167.25 2 2
2 12 1164.84 2 15.31 2054 63 0.27 / 167.31 2 3
3 7 2006.52 30 14.89 3049 1362 1.63 / 168.67 3 3
4 13 1505.96 25 14.91 2401 895 2.53 / 169.57 2 4
5 13 789.88 25 15.06 1465 552 3.08 / 170.12 2 6
6 13 151.48 25 15.26 548 209 3.29 / 170.33 2 3
7 8 0.12 165 15.26 308 776 4.06 / 171.11 2 8
Average= 4.07
(KJ/cycle)

Cycle 40 GMT 14/ 9/2019 3:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 15.24 446 204 0.20 / 163.18 2 2
2 12 1177.04 2 15.30 2078 64 0.27 / 163.24 2 2
3 7 2002.88 30 14.91 3035 1358 1.63 / 164.60 2 3
4 13 1534.20 25 14.91 2448 912 2.54 / 165.51 2 5
5 13 837.08 25 15.05 1528 575 3.11 / 166.09 2 5
6 13 155.68 25 15.26 546 208 3.32 / 166.29 2 4
7 8 0.20 165 15.27 298 751 4.07 / 167.04 2 9
Average= 4.07
(KJ/cycle)

Cycle 39 GMT 4/ 9/2019 5: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 30 15.23 451 206 0.21 / 159.08 2 2
2 12 1166.12 2 15.31 2042 63 0.27 / 159.14 2 3
3 7 2005.24 30 14.91 3032 1356 1.62 / 160.50 3 4
4 13 1533.48 25 14.91 2465 919 2.54 / 161.42 2 5
5 13 832.12 25 15.05 1540 579 3.12 / 162.00 2 5
6 13 154.64 25 15.26 555 212 3.33 / 162.21 2 3
7 8 0.20 165 15.27 304 766 4.10 / 162.97 2 7
Average= 4.07
(KJ/cycle)

Cycle 38 GMT 25/ 8/2019 6:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 30 15.23 445 203 0.20 / 154.86 2 2
2 12 1168.36 2 15.30 2045 63 0.27 / 154.93 2 2
3 7 2005.20 30 14.90 3048 1362 1.63 / 156.29 2 4
4 13 1528.00 25 14.92 2458 917 2.55 / 157.21 2 4
5 13 818.12 25 15.06 1503 566 3.11 / 157.77 2 5
6 13 153.48 25 15.26 549 209 3.32 / 157.98 2 3
7 13 16.04 25 15.29 334 128 3.45 / 158.11 2 4
8 8 -0.08 165 15.26 303 763 4.21 / 158.87 2 9
Average= 4.07
(KJ/cycle)

Cycle 37 GMT 15/ 8/2019 8:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 30 15.25 434 199 0.20 / 150.73 2 2
2 12 1156.56 2 15.31 2040 62 0.26 / 150.80 2 2
3 7 2003.52 30 14.91 3028 1354 1.62 / 152.15 2 4
4 13 1379.12 25 14.96 2271 849 2.46 / 153.00 2 5
5 13 730.40 25 15.08 1396 526 2.99 / 153.53 2 6
6 13 186.44 25 15.25 603 230 3.22 / 153.76 2 4
7 13 18.40 25 15.29 345 132 3.35 / 153.89 2 4
8 8 0.00 165 15.26 307 773 4.13 / 154.66 2 9
Average= 4.07
(KJ/cycle)

Cycle 36 GMT 5/ 8/2019 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 30 15.25 450 206 0.21 / 146.63 2 2
2 12 1316.68 2 15.26 2262 69 0.27 / 146.70 2 2
3 7 2003.48 31 14.91 3043 1407 1.68 / 148.11 2 3
4 13 1504.24 25 14.93 2414 901 2.58 / 149.01 2 4
5 13 793.64 25 15.08 1487 561 3.14 / 149.57 2 4
6 13 137.00 25 15.28 525 201 3.34 / 149.77 2 4
7 8 0.16 165 15.28 303 764 4.11 / 150.54 2 8
Average= 4.07
(KJ/cycle)

Cycle 35 GMT 26/ 7/2019 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 15.26 441 202 0.20 / 142.48 2 2
2 12 1156.12 2 15.32 2050 63 0.26 / 142.54 2 2
3 7 2003.28 30 14.91 3028 1354 1.62 / 143.90 2 4
4 13 1675.84 25 14.90 2622 977 2.60 / 144.88 2 4
5 13 758.52 25 15.09 1437 542 3.14 / 145.42 2 5
6 13 211.24 25 15.25 639 244 3.38 / 145.66 2 4
7 8 0.20 165 15.28 304 766 4.15 / 146.43 2 8
Average= 4.07
(KJ/cycle)

Cycle 34 GMT 16/ 7/2019 13:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 30 15.24 450 206 0.21 / 138.41 2 2
2 12 1312.48 2 15.28 2239 68 0.27 / 138.48 2 2
3 7 2008.00 30 14.92 3030 1356 1.63 / 139.84 2 4
4 13 1522.76 25 14.94 2438 911 2.54 / 140.75 2 6
5 13 813.16 25 15.08 1503 567 3.11 / 141.32 2 6
6 13 141.88 25 15.28 542 207 3.31 / 141.52 2 3
7 8 0.24 165 15.29 300 757 4.07 / 142.28 2 7
Average= 4.07
(KJ/cycle)

Cycle 33 GMT 6/ 7/2019 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 30 15.26 439 201 0.20 / 133.97 2 2
2 12 1172.32 2 15.32 2049 63 0.26 / 134.03 2 2
3 7 2002.84 30 14.92 3022 1353 1.62 / 135.38 2 5
4 13 1508.60 25 14.94 2413 901 2.52 / 136.28 2 4
5 13 809.84 25 15.08 1495 564 3.08 / 136.85 2 5
6 13 139.48 25 15.28 540 206 3.29 / 137.05 2 4
7 8 0.44 165 15.28 318 802 4.09 / 137.86 2 7
8 14 0.44 75 15.25 309 353 4.44 / 138.21 2 15
Average= 4.06
(KJ/cycle)

Cycle 32 GMT 26/ 6/2019 17:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 30 15.26 440 201 0.20 / 129.90 2 2
2 12 1157.96 2 15.33 2051 63 0.26 / 129.96 2 2
3 7 2007.12 30 14.92 3032 1357 1.62 / 131.32 2 4
4 13 1529.12 25 14.94 2459 918 2.54 / 132.23 2 4
5 13 813.04 25 15.09 1510 570 3.11 / 132.80 2 6
6 13 145.48 25 15.28 542 207 3.32 / 133.01 2 4
7 8 0.24 165 15.29 299 754 4.07 / 133.77 2 8
Average= 4.05
(KJ/cycle)

Cycle 31 GMT 16/ 6/2019 19:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 30 15.25 452 207 0.21 / 125.61 2 2
2 12 1172.80 2 15.32 2058 63 0.27 / 125.67 2 3
3 7 2003.60 30 14.92 3035 1358 1.63 / 127.03 3 4
4 13 1668.56 25 14.92 2627 980 2.61 / 128.01 2 4
5 13 774.56 25 15.10 1440 544 3.15 / 128.56 2 5
6 13 212.64 25 15.27 636 243 3.39 / 128.80 2 4
7 13 41.92 25 15.31 370 142 3.54 / 128.94 2 4
8 8 0.12 165 15.28 299 754 4.29 / 129.70 2 8
Average= 4.05
(KJ/cycle)

Cycle 30 GMT 6/ 6/2019 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 30 15.26 459 210 0.21 / 121.33 2 2
2 12 1174.76 2 15.33 2049 63 0.27 / 121.40 2 2
3 7 2001.08 30 14.93 3028 1356 1.63 / 122.75 2 4
4 13 1510.12 25 14.96 2432 910 2.54 / 123.66 2 4
5 13 779.84 25 15.10 1457 550 3.09 / 124.21 2 4
6 13 203.16 25 15.26 644 246 3.33 / 124.46 2 4
7 13 41.00 25 15.31 391 150 3.48 / 124.61 2 4
8 8 0.12 165 15.28 316 797 4.28 / 125.40 2 10
Average= 4.05
(KJ/cycle)

Cycle 29 GMT 27/ 5/2019 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 30 15.26 447 205 0.20 / 117.12 2 2
2 12 1161.84 2 15.33 2055 63 0.27 / 117.18 2 2
3 7 2006.24 30 14.94 3043 1364 1.63 / 118.55 2 4
4 13 1511.28 25 14.96 2435 911 2.54 / 119.46 2 4
5 13 692.32 25 15.14 1343 508 3.05 / 119.97 2 6
6 13 171.00 25 15.29 579 221 3.27 / 120.19 2 4
7 13 42.72 25 15.31 387 148 3.42 / 120.34 2 4
8 8 0.04 165 15.29 312 787 4.21 / 121.12 2 9
Average= 4.04
(KJ/cycle)

Cycle 28 GMT 18/ 5/2019 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 30 15.27 450 206 0.21 / 112.83 2 2
2 12 1165.56 2 15.33 2034 62 0.27 / 112.89 2 2
3 7 2001.92 30 14.94 3018 1353 1.62 / 114.24 2 4
4 13 1664.96 25 14.93 2616 976 2.60 / 115.22 2 4
5 13 769.20 25 15.12 1451 548 3.15 / 115.77 2 5
6 13 204.32 25 15.28 642 245 3.39 / 116.01 2 4
7 13 40.80 25 15.32 371 142 3.53 / 116.16 2 4
8 8 0.12 165 15.29 302 762 4.30 / 116.92 2 13
Average= 4.03
(KJ/cycle)

Cycle 27 GMT 8/ 5/2019 2:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 30 15.27 451 207 0.21 / 108.55 2 2
2 12 1318.92 2 15.31 2261 69 0.28 / 108.62 2 2
3 7 2008.36 30 14.94 3037 1361 1.64 / 109.98 2 3
4 13 1535.72 25 14.96 2467 923 2.56 / 110.91 2 4
5 13 826.88 25 15.10 1529 577 3.14 / 111.48 2 6
6 13 150.60 25 15.30 554 212 3.35 / 111.69 2 4
7 13 39.08 25 15.32 383 147 3.50 / 111.84 2 4
8 8 -0.04 165 15.30 309 780 4.28 / 112.62 2 9
Average= 4.02
(KJ/cycle)

Cycle 26 GMT 28/ 4/2019 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 29 15.28 435 193 0.19 / 104.15 2 2
2 12 1177.12 2 15.35 2062 63 0.26 / 104.22 2 3
3 7 2003.16 30 14.95 3055 1370 1.63 / 105.59 3 4
4 13 1676.80 25 14.93 2634 983 2.61 / 106.57 2 4
5 13 936.20 25 15.07 1674 631 3.24 / 107.20 2 4
6 13 184.96 25 15.29 594 227 3.47 / 107.43 2 4
7 13 43.60 25 15.32 381 146 3.61 / 107.57 2 4
8 8 0.00 165 15.30 306 772 4.39 / 108.35 2 11
Average= 4.01
(KJ/cycle)

Cycle 25 GMT 18/ 4/2019 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 15.28 450 199 0.20 / 99.93 2 2
2 12 1173.76 2 15.34 2058 63 0.26 / 99.99 2 2
3 7 2003.72 30 14.94 3039 1362 1.62 / 101.36 2 3
4 13 1521.92 25 14.97 2445 915 2.54 / 102.27 2 4
5 13 813.48 25 15.11 1507 569 3.11 / 102.84 2 4
6 13 149.72 25 15.30 549 210 3.32 / 103.05 2 3
7 13 39.00 25 15.33 374 143 3.46 / 103.19 2 4
8 8 0.08 165 15.30 304 767 4.23 / 103.96 2 9
Average= 4.00
(KJ/cycle)

Cycle 24 GMT 8/ 4/2019 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 15.28 457 203 0.20 / 95.70 2 2
2 12 1183.04 2 15.35 2074 64 0.27 / 95.76 2 2
3 7 2003.60 30 14.96 3049 1368 1.63 / 97.13 2 3
4 13 1533.08 25 14.97 2452 918 2.55 / 98.05 2 4
5 13 794.32 25 15.12 1481 560 3.11 / 98.61 2 4
6 13 137.28 25 15.32 530 203 3.32 / 98.81 2 3
7 13 35.88 25 15.33 377 144 3.46 / 98.95 2 4
8 8 0.16 165 15.31 308 778 4.24 / 99.73 2 10
Average= 3.99
(KJ/cycle)

Cycle 23 GMT 29/ 3/2019 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 29 15.29 443 196 0.20 / 91.42 2 2
2 12 1155.44 2 15.35 2031 62 0.26 / 91.48 2 2
3 7 2002.76 30 14.96 3028 1359 1.62 / 92.84 2 3
4 13 1499.56 25 14.99 2416 905 2.52 / 93.75 2 3
5 13 761.96 25 15.14 1450 549 3.07 / 94.30 2 4
6 13 192.36 25 15.29 628 240 3.31 / 94.54 2 4
7 13 36.00 25 15.33 388 149 3.46 / 94.69 2 4
8 8 0.00 165 15.30 320 808 4.27 / 95.49 2 9
Average= 3.98
(KJ/cycle)

Cycle 22 GMT 19/ 3/2019 10:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 29 15.28 462 205 0.20 / 87.22 2 2
2 12 1172.76 2 15.35 2067 63 0.27 / 87.28 2 2
3 7 2004.40 30 14.96 3030 1360 1.63 / 88.64 2 3
4 13 1515.72 25 14.99 2431 911 2.54 / 89.55 2 3
5 13 805.40 25 15.12 1502 568 3.11 / 90.12 2 4
6 13 139.76 25 15.32 524 201 3.31 / 90.32 2 3
7 13 30.60 25 15.34 360 138 3.45 / 90.46 2 4
8 8 0.08 165 15.32 302 763 4.21 / 91.22 2 9
Average= 3.97
(KJ/cycle)

Cycle 21 GMT 9/ 3/2019 12:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 29 15.29 450 200 0.20 / 83.01 2 2
2 12 1162.84 2 15.36 2056 63 0.26 / 83.07 2 2
3 7 2002.52 30 14.96 3040 1364 1.63 / 84.44 2 3
4 13 1371.64 25 15.02 2253 846 2.47 / 85.28 2 3
5 13 825.48 25 15.12 1530 578 3.05 / 85.86 2 5
6 13 140.04 25 15.32 539 206 3.26 / 86.07 2 4
7 13 35.68 25 15.34 379 145 3.40 / 86.21 2 4
8 8 0.00 165 15.32 318 804 4.21 / 87.02 2 11
Average= 3.96
(KJ/cycle)

Cycle 20 GMT 27/ 2/2019 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 29 15.30 443 197 0.20 / 78.83 2 2
2 12 1169.64 2 15.36 2058 63 0.26 / 78.89 2 2
3 7 2002.00 30 14.97 3032 1362 1.62 / 80.26 2 3
4 13 1512.84 25 15.00 2434 913 2.53 / 81.17 2 3
5 13 661.32 25 15.18 1300 493 3.03 / 81.66 2 4
6 13 156.48 25 15.32 563 216 3.24 / 81.88 2 3
7 13 37.32 25 15.35 379 145 3.39 / 82.02 2 4
8 8 0.04 165 15.32 311 786 4.17 / 82.81 2 11
Average= 3.94
(KJ/cycle)

Cycle 19 GMT 17/ 2/2019 16: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 29 15.29 458 203 0.20 / 74.58 2 2
2 12 1178.88 2 15.36 2052 63 0.27 / 74.64 2 2
3 7 2001.96 30 14.97 3039 1365 1.63 / 76.01 2 3
4 13 1529.08 25 14.99 2451 919 2.55 / 76.93 2 4
5 13 811.00 25 15.13 1508 570 3.12 / 77.50 2 4
6 13 138.52 25 15.33 537 206 3.33 / 77.70 2 3
7 13 32.60 25 15.35 377 145 3.47 / 77.85 2 4
8 8 0.00 165 15.32 311 786 4.26 / 78.63 2 11
Average= 3.93
(KJ/cycle)

Cycle 18 GMT 7/ 2/2019 17:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 29 15.30 463 205 0.21 / 70.22 2 2
2 12 1181.48 2 15.36 2079 64 0.27 / 70.29 2 2
3 7 2002.36 30 14.98 3035 1364 1.63 / 71.65 2 3
4 13 1659.48 25 14.97 2622 981 2.61 / 72.63 2 3
5 13 754.48 25 15.15 1438 545 3.16 / 73.18 2 4
6 13 190.60 25 15.31 629 241 3.40 / 73.42 2 4
7 13 40.40 25 15.35 394 151 3.55 / 73.57 2 5
8 8 0.08 165 15.32 320 809 4.36 / 74.38 2 11
Average= 3.91
(KJ/cycle)

Cycle 17 GMT 28/ 1/2019 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 29 15.29 465 206 0.21 / 65.97 2 2
2 12 1309.76 2 15.34 2239 69 0.27 / 66.04 2 2
3 7 2003.16 30 14.98 3034 1363 1.64 / 67.40 2 3
4 13 1510.76 25 15.01 2426 910 2.55 / 68.31 2 4
5 13 791.24 25 15.14 1482 561 3.11 / 68.88 2 4
6 13 135.32 25 15.34 534 205 3.31 / 69.08 2 3
7 13 35.28 25 15.36 380 146 3.46 / 69.23 2 4
8 8 -0.04 165 15.33 313 792 4.25 / 70.02 2 13
Average= 3.89
(KJ/cycle)

Cycle 16 GMT 18/ 1/2019 20:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 29 15.30 457 203 0.20 / 61.59 2 2
2 12 1161.52 2 15.38 2044 63 0.27 / 61.66 2 2
3 7 2003.80 31 14.98 3046 1415 1.68 / 63.07 2 3
4 13 1523.60 25 15.01 2445 917 2.60 / 63.99 2 3
5 13 781.28 25 15.15 1470 557 3.15 / 64.54 2 5
6 13 204.36 25 15.31 646 247 3.40 / 64.79 2 4
7 13 41.36 25 15.35 398 153 3.55 / 64.94 2 5
8 8 0.00 165 15.32 325 822 4.38 / 65.77 2 9
Average= 3.87
(KJ/cycle)

Cycle 15 GMT 8/ 1/2019 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 29 15.30 467 207 0.21 / 57.31 2 2
2 12 1184.28 2 15.37 2081 64 0.27 / 57.38 2 2
3 7 2015.08 30 14.98 3059 1375 1.65 / 58.75 2 2
4 13 1529.76 25 15.01 2457 922 2.57 / 59.68 2 3
5 13 791.72 25 15.15 1488 564 3.13 / 60.24 2 5
6 13 131.28 25 15.34 528 202 3.33 / 60.44 2 4
7 13 30.84 25 15.36 374 144 3.48 / 60.59 2 4
8 8 0.16 165 15.33 318 804 4.28 / 61.39 2 10
Average= 3.84
(KJ/cycle)

Cycle 14 GMT 29/12/2018 23:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 29 15.31 457 203 0.20 / 53.08 2 2
2 12 1168.68 2 15.39 2022 62 0.27 / 53.14 2 2
3 7 2005.60 30 14.97 3042 1366 1.63 / 54.51 2 2
4 13 1516.64 25 15.01 2437 914 2.55 / 55.42 2 3
5 13 660.00 25 15.19 1308 497 3.04 / 55.92 2 4
6 13 140.72 25 15.34 551 211 3.25 / 56.13 2 3
7 13 31.32 25 15.36 385 148 3.40 / 56.28 2 4
8 8 0.12 165 15.33 327 827 4.23 / 57.11 2 10
Average= 3.81
(KJ/cycle)

Cycle 13 GMT 19/12/2018 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 15.31 476 211 0.21 / 48.81 2 2
2 12 1155.40 2 15.39 2009 62 0.27 / 48.88 2 2
3 7 2004.04 30 15.00 3035 1366 1.64 / 50.24 2 2
4 13 1510.08 25 15.03 2430 913 2.55 / 51.15 2 3
5 13 788.84 25 15.16 1484 562 3.11 / 51.72 2 3
6 13 141.84 25 15.34 544 209 3.32 / 51.93 2 3
7 13 29.56 25 15.37 373 143 3.47 / 52.07 2 3
8 8 0.00 165 15.34 320 810 4.28 / 52.88 2 9
Average= 3.78
(KJ/cycle)

Cycle 12 GMT 10/12/2018 1:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 15.32 464 206 0.21 / 44.67 2 2
2 12 1178.32 2 15.39 2049 63 0.27 / 44.73 2 2
3 7 2003.08 30 15.00 3034 1365 1.63 / 46.10 2 2
4 13 1506.80 25 15.03 2426 912 2.55 / 47.01 2 3
5 13 789.24 25 15.16 1486 563 3.11 / 47.57 2 4
6 13 141.04 25 15.35 545 209 3.32 / 47.78 2 3
7 8 0.12 165 15.35 325 823 4.14 / 48.60 2 8
Average= 3.74
(KJ/cycle)

Cycle 11 GMT 30/11/2018 2:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 29 15.32 468 208 0.21 / 40.51 2 2
2 12 1169.72 2 15.39 2059 63 0.27 / 40.57 2 2
3 7 2004.08 30 15.00 3048 1372 1.64 / 41.94 2 2
4 13 1506.88 25 15.03 2439 916 2.56 / 42.86 2 3
5 13 793.72 25 15.16 1500 568 3.13 / 43.43 2 4
6 13 135.12 25 15.35 542 208 3.34 / 43.64 2 3
7 8 0.24 165 15.35 325 823 4.16 / 44.46 2 7
Average= 3.71
(KJ/cycle)

Cycle 10 GMT 20/11/2018 3:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 15.32 475 204 0.20 / 36.33 2 2
2 12 1166.72 2 15.39 2072 64 0.27 / 36.40 2 2
3 7 2001.04 30 15.00 3042 1369 1.64 / 37.77 2 2
4 13 1491.76 25 15.04 2413 907 2.54 / 38.67 2 3
5 13 776.40 25 15.17 1472 558 3.10 / 39.23 2 4
6 13 201.48 25 15.32 648 248 3.35 / 39.48 2 4
7 8 0.12 165 15.35 325 823 4.17 / 40.30 2 8
Average= 3.66
(KJ/cycle)

Cycle 9 GMT 10/11/2018 4:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 28 15.32 475 204 0.20 / 32.21 2 2
2 12 1327.44 2 15.36 2276 70 0.27 / 32.28 2 2
3 7 2001.80 30 15.02 3038 1369 1.64 / 33.65 2 2
4 13 1518.52 25 15.04 2446 920 2.56 / 34.57 2 3
5 13 658.32 25 15.21 1309 498 3.06 / 35.07 2 3
6 13 158.00 25 15.34 580 222 3.28 / 35.29 2 3
7 8 0.28 165 15.35 330 836 4.12 / 36.13 2 6
Average= 3.61
(KJ/cycle)

Cycle 8 GMT 31/10/2018 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 28 15.31 478 205 0.20 / 28.09 2 2
2 12 1174.24 2 15.40 2060 63 0.27 / 28.16 2 2
3 7 2001.68 30 15.02 3049 1374 1.64 / 29.53 2 2
4 13 1376.36 25 15.07 2255 850 2.49 / 30.38 2 3
5 13 839.96 25 15.15 1555 589 3.08 / 30.97 2 4
6 13 140.16 25 15.35 552 212 3.29 / 31.18 2 3
7 8 0.08 165 15.35 327 828 4.12 / 32.01 2 8
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 21/10/2018 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 28 15.32 466 200 0.20 / 23.91 2 2
2 12 1313.16 2 15.37 2268 70 0.27 / 23.98 2 2
3 7 2000.04 30 15.01 3050 1373 1.64 / 25.35 2 2
4 13 1498.60 25 15.04 2430 914 2.56 / 26.26 2 3
5 13 758.48 25 15.18 1452 551 3.11 / 26.81 2 4
6 13 192.12 25 15.33 639 245 3.35 / 27.06 2 3
7 8 0.08 165 15.35 328 831 4.18 / 27.89 2 6
Average= 3.49
(KJ/cycle)

Cycle 6 GMT 11/10/2018 6:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 27 15.33 464 192 0.19 / 19.73 2 2
2 10 1010.20 2 15.30 1821 56 0.25 / 19.79 2 2
3 7 2003.80 39 14.98 3030 1770 2.02 / 21.56 2 2
4 13 1309.80 18 15.10 2166 589 2.61 / 22.14 2 3
5 13 784.12 18 15.19 1482 405 3.01 / 22.55 2 3
6 13 267.48 18 15.32 758 209 3.22 / 22.76 2 3
7 13 81.52 18 15.37 456 126 3.35 / 22.89 2 3
8 8 0.12 165 15.36 324 821 4.17 / 23.71 2 9
Average= 3.39
(KJ/cycle)

Cycle 5 GMT 1/10/2018 8:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 28 15.33 472 203 0.20 / 15.70 2 2
2 3 973.36 -1 15.66 0 0 0.00 / 15.70 2 2
3 7 2003.48 38 14.99 2995 1706 1.91 / 17.41 2 2
4 13 1300.96 18 15.11 2145 583 2.49 / 17.99 2 2
5 13 783.92 18 15.20 1478 404 2.90 / 18.39 2 3
6 13 253.08 18 15.33 728 201 3.10 / 18.59 2 3
7 13 79.84 18 15.37 454 126 3.22 / 18.72 2 3
8 8 0.12 165 15.36 323 819 4.04 / 19.54 2 6
Average= 3.26
(KJ/cycle)

Cycle 4 GMT 21/ 9/2018 10:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 27 15.34 466 193 0.19 / 12.09 2 2
2 7 1507.04 38 15.14 2386 1373 1.57 / 13.47 2 2
3 13 1200.52 18 15.17 2007 548 2.11 / 14.01 2 2
4 13 673.52 18 15.25 1328 365 2.48 / 14.38 2 3
5 13 171.40 18 15.37 591 164 2.64 / 14.54 2 3
6 13 90.24 18 15.38 473 131 2.77 / 14.67 2 2
7 8 0.08 165 15.37 325 824 3.60 / 15.50 2 5
Average= 3.10
(KJ/cycle)

Cycle 3 GMT 20/ 9/2018 10:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 27 15.35 440 182 0.18 / 8.54 2 2
2 7 1517.48 38 15.14 2377 1368 1.55 / 9.91 2 2
3 13 1207.00 18 15.17 1997 545 2.10 / 10.46 2 2
4 13 681.80 18 15.25 1319 362 2.46 / 10.82 2 3
5 13 177.84 18 15.37 593 164 2.62 / 10.98 2 3
6 13 95.64 18 15.38 467 129 2.75 / 11.11 2 3
7 8 0.20 165 15.37 311 789 3.54 / 11.90 2 6
Average= 2.97
(KJ/cycle)

Cycle 2 GMT 19/ 9/2018 10:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 15.38 418 180 0.18 / 4.68 2 2
2 3 946.48 -1 15.68 0 0 0.00 / 4.68 2 2
3 7 1519.88 74 15.06 2354 2623 2.80 / 7.31 2 2
4 13 238.16 18 15.36 667 184 2.99 / 7.49 2 3
5 13 78.92 18 15.40 422 117 3.10 / 7.61 2 2
6 8 0.08 165 15.38 296 751 3.86 / 8.36 2 5
Average= 2.79
(KJ/cycle)

Cycle 1 GMT 18/ 9/2018 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 28 15.58 373 163 0.16 / 1.60 2 2
2 3 935.08 -1 15.69 0 0 0.00 / 1.60 2 2
3 7 980.36 74 15.24 1651 1862 2.02 / 3.46 2 3
4 8 0.12 240 15.43 282 1044 3.07 / 4.50 2 11
Average= 2.25
(KJ/cycle)

Cycle 0 GMT 17/ 9/2018 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.04 22 15.72 403 139 0.14 / 0.14 2 2
2 7 138.36 74 15.69 411 477 0.62 / 0.62 2 2
3 8 0.24 240 15.65 218 819 1.44 / 1.44 2 8
Average= 1.44
(KJ/cycle)