SIO Argo Site:
Pump Diagnostics Page   



Serial= 8689 WMO= 5905704

Return

←PreviousNext→

Cycle 234 GMT 14/12/2024 15:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 34 14.86 408 206 0.21 / 938.00 2 2
2 7 2010.80 36 14.61 2887 1518 1.72 / 939.51 2 2
3 13 1528.36 21 14.62 2318 712 2.44 / 940.23 2 2
4 13 898.60 21 14.68 1518 468 2.90 / 940.69 2 3
5 13 379.84 21 14.80 847 263 3.17 / 940.96 2 3
6 13 92.76 21 14.89 421 132 3.30 / 941.09 2 2
7 13 24.60 21 14.91 314 98 3.40 / 941.19 2 2
8 8 0.08 165 14.88 270 663 4.06 / 941.85 2 6
Average= 4.01
(KJ/cycle)

Cycle 233 GMT 4/12/2024 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 34 14.86 405 205 0.20 / 934.02 2 2
2 7 2004.88 36 14.61 2880 1515 1.72 / 935.53 2 2
3 13 1526.36 21 14.61 2319 711 2.43 / 936.24 2 2
4 13 1005.00 21 14.66 1666 513 2.94 / 936.76 2 3
5 13 296.60 21 14.83 739 230 3.17 / 936.99 2 3
6 13 68.80 21 14.90 388 121 3.30 / 937.11 2 3
7 8 0.12 165 14.89 277 681 3.98 / 937.79 2 4
Average= 4.01
(KJ/cycle)

Cycle 232 GMT 24/11/2024 20:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 34 14.86 407 206 0.21 / 930.00 2 2
2 7 2005.64 36 14.62 2889 1521 1.73 / 931.52 2 3
3 13 1532.64 21 14.61 2352 722 2.45 / 932.25 2 3
4 13 1026.00 21 14.65 1705 525 2.97 / 932.77 2 3
5 13 306.56 21 14.82 757 236 3.21 / 933.01 2 3
6 13 65.36 21 14.90 380 119 3.33 / 933.12 2 3
7 8 0.12 165 14.88 281 690 4.02 / 933.81 2 6
Average= 4.01
(KJ/cycle)

Cycle 231 GMT 14/11/2024 22:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 34 14.86 410 207 0.21 / 925.93 2 2
2 7 2009.56 36 14.62 2871 1511 1.72 / 927.44 2 3
3 13 1682.52 21 14.61 2509 770 2.49 / 928.21 2 3
4 13 1007.04 21 14.66 1682 518 3.01 / 928.73 2 2
5 13 310.32 21 14.82 784 244 3.25 / 928.98 2 3
6 13 71.76 21 14.90 397 124 3.37 / 929.10 2 2
7 8 0.04 165 14.89 284 698 4.07 / 929.80 2 5
Average= 4.01
(KJ/cycle)

Cycle 230 GMT 5/11/2024 1:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 34 14.86 406 205 0.21 / 921.92 2 2
2 7 2009.40 36 14.61 2883 1516 1.72 / 923.43 2 3
3 13 1528.48 21 14.62 2338 718 2.44 / 924.15 2 2
4 13 1026.64 21 14.65 1697 522 2.96 / 924.67 2 3
5 13 312.08 21 14.82 772 240 3.20 / 924.91 2 3
6 13 71.60 21 14.89 394 123 3.32 / 925.04 2 2
7 8 0.00 165 14.88 280 687 4.01 / 925.73 2 3
Average= 4.01
(KJ/cycle)

Cycle 229 GMT 26/10/2024 3:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 34 14.86 412 208 0.21 / 917.93 2 2
2 7 2013.44 36 14.62 2876 1514 1.72 / 919.45 3 3
3 13 1535.80 21 14.62 2349 721 2.44 / 920.17 2 2
4 13 888.60 21 14.68 1530 472 2.91 / 920.64 2 4
5 13 362.08 21 14.80 833 259 3.17 / 920.90 2 3
6 13 87.40 21 14.89 415 130 3.30 / 921.03 2 2
7 8 0.04 165 14.88 279 685 3.99 / 921.71 2 4
Average= 4.01
(KJ/cycle)

Cycle 228 GMT 16/10/2024 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 34 14.86 417 211 0.21 / 913.93 2 2
2 7 2007.76 36 14.61 2887 1518 1.73 / 915.45 2 3
3 13 1668.08 21 14.60 2508 769 2.50 / 916.22 2 2
4 13 827.84 21 14.70 1458 450 2.95 / 916.67 2 4
5 13 329.48 21 14.81 799 248 3.20 / 916.92 2 3
6 13 86.52 21 14.89 414 129 3.33 / 917.04 2 2
7 8 0.04 165 14.88 277 680 4.01 / 917.72 2 6
Average= 4.01
(KJ/cycle)

Cycle 227 GMT 6/10/2024 8:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 34 14.86 426 215 0.22 / 909.95 2 2
2 7 2008.68 36 14.62 2887 1519 1.73 / 911.46 2 3
3 13 1524.68 21 14.61 2334 716 2.45 / 912.18 2 2
4 13 879.40 21 14.68 1515 467 2.92 / 912.65 2 2
5 13 349.04 21 14.80 831 258 3.18 / 912.91 2 3
6 13 84.80 21 14.89 416 130 3.31 / 913.04 2 2
7 8 0.04 165 14.88 278 683 3.99 / 913.72 2 6
Average= 4.01
(KJ/cycle)

Cycle 226 GMT 26/ 9/2024 10:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 34 14.86 418 211 0.21 / 905.87 2 2
2 7 2010.72 36 14.61 2885 1517 1.73 / 907.39 2 3
3 13 1682.40 21 14.59 2544 779 2.51 / 908.17 2 2
4 13 974.28 21 14.66 1639 505 3.01 / 908.67 2 4
5 13 307.04 21 14.82 771 240 3.25 / 908.91 2 2
6 13 81.44 21 14.90 406 127 3.38 / 909.04 2 2
7 8 0.16 165 14.88 281 690 4.07 / 909.73 2 7
Average= 4.01
(KJ/cycle)

Cycle 225 GMT 16/ 9/2024 13: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 34 14.87 402 203 0.20 / 901.86 2 2
2 7 2006.20 36 14.62 2889 1521 1.72 / 903.38 2 3
3 13 1524.20 21 14.62 2334 717 2.44 / 904.10 2 3
4 13 992.24 21 14.66 1672 515 2.96 / 904.61 2 3
5 13 307.72 21 14.82 765 238 3.19 / 904.85 2 3
6 13 83.68 21 14.90 407 127 3.32 / 904.98 2 2
7 8 0.04 165 14.88 278 683 4.00 / 905.66 2 5
Average= 4.01
(KJ/cycle)

Cycle 224 GMT 6/ 9/2024 15:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 34 14.86 418 211 0.21 / 897.72 2 2
2 7 2010.56 37 14.62 2875 1555 1.77 / 899.28 2 2
3 13 1526.96 21 14.62 2325 714 2.48 / 899.99 2 2
4 13 1021.44 21 14.65 1714 527 3.01 / 900.52 2 3
5 13 325.52 21 14.82 775 241 3.25 / 900.76 2 3
6 13 94.84 21 14.89 414 129 3.38 / 900.89 2 2
7 8 0.12 165 14.89 272 668 4.05 / 901.56 2 3
8 14 0.12 25 14.87 270 100 4.15 / 901.66 2 4
Average= 4.01
(KJ/cycle)

Cycle 223 GMT 27/ 8/2024 17:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 34 14.86 411 208 0.21 / 893.70 2 2
2 7 2015.56 36 14.61 2895 1523 1.73 / 895.22 2 3
3 13 1518.68 21 14.62 2335 717 2.45 / 895.94 2 2
4 13 1013.44 21 14.65 1700 523 2.97 / 896.46 2 3
5 13 318.20 21 14.82 775 241 3.21 / 896.70 2 3
6 13 93.00 21 14.89 422 132 3.34 / 896.84 2 2
7 8 -0.04 165 14.88 275 675 4.02 / 897.51 2 4
Average= 4.01
(KJ/cycle)

Cycle 222 GMT 17/ 8/2024 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 34 14.86 408 206 0.21 / 889.73 2 2
2 7 2016.40 36 14.61 2885 1517 1.72 / 891.25 2 2
3 13 1536.00 21 14.62 2338 718 2.44 / 891.96 2 2
4 13 868.88 21 14.69 1492 460 2.90 / 892.42 2 3
5 13 358.60 21 14.80 841 261 3.16 / 892.69 2 4
6 13 104.96 21 14.88 437 137 3.30 / 892.82 2 2
7 8 0.16 165 14.88 273 670 3.97 / 893.49 2 4
Average= 4.01
(KJ/cycle)

Cycle 221 GMT 7/ 8/2024 22:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 34 14.85 418 211 0.21 / 885.74 2 2
2 7 2014.40 36 14.62 2893 1523 1.73 / 887.26 2 3
3 13 1527.12 21 14.62 2321 713 2.45 / 887.97 2 2
4 13 1002.08 21 14.67 1667 514 2.96 / 888.49 2 4
5 13 309.20 21 14.82 757 236 3.20 / 888.72 2 3
6 13 85.48 21 14.89 411 129 3.32 / 888.85 2 2
7 8 0.08 165 14.89 273 671 3.99 / 889.52 2 6
Average= 4.01
(KJ/cycle)

Cycle 220 GMT 29/ 7/2024 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 34 14.86 405 205 0.20 / 881.76 2 2
2 7 2005.88 36 14.62 2890 1521 1.73 / 883.28 2 2
3 13 1533.56 21 14.62 2327 714 2.44 / 883.99 2 2
4 13 872.72 21 14.69 1506 465 2.90 / 884.46 2 3
5 13 350.00 21 14.81 815 253 3.16 / 884.71 2 2
6 13 98.68 21 14.89 427 134 3.29 / 884.84 2 2
7 8 0.12 165 14.88 278 683 3.97 / 885.53 2 4
Average= 4.01
(KJ/cycle)

Cycle 219 GMT 19/ 7/2024 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 34 14.85 417 211 0.21 / 877.77 2 2
2 7 2013.88 36 14.62 2871 1511 1.72 / 879.28 2 2
3 13 1539.20 21 14.61 2360 724 2.45 / 880.00 2 2
4 13 992.68 21 14.66 1671 514 2.96 / 880.52 2 3
5 13 301.84 21 14.82 748 233 3.19 / 880.75 2 3
6 13 84.96 21 14.89 405 127 3.32 / 880.88 2 2
7 8 0.16 165 14.88 275 675 3.99 / 881.55 2 4
Average= 4.01
(KJ/cycle)

Cycle 218 GMT 9/ 7/2024 5: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 34 14.86 417 211 0.21 / 873.77 2 2
2 7 2008.64 36 14.62 2876 1514 1.72 / 875.28 2 2
3 13 1525.64 21 14.62 2339 718 2.44 / 876.00 2 3
4 13 858.84 21 14.69 1494 461 2.90 / 876.46 2 3
5 13 349.36 21 14.81 819 255 3.16 / 876.72 2 3
6 13 87.48 21 14.88 435 136 3.29 / 876.85 2 2
7 8 -0.08 165 14.87 287 704 4.00 / 877.56 2 4
Average= 4.01
(KJ/cycle)

Cycle 217 GMT 29/ 6/2024 7:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 34 14.86 408 206 0.21 / 869.60 2 2
2 7 2005.88 36 14.62 2885 1518 1.72 / 871.12 2 2
3 13 1674.12 21 14.60 2525 774 2.50 / 871.90 2 3
4 13 938.24 21 14.68 1586 489 2.99 / 872.38 2 2
5 13 402.08 21 14.79 892 277 3.26 / 872.66 2 3
6 13 81.88 21 14.89 405 127 3.39 / 872.79 2 2
7 13 26.80 21 14.90 319 100 3.49 / 872.89 2 2
8 8 0.12 165 14.88 274 673 4.16 / 873.56 2 4
Average= 4.01
(KJ/cycle)

Cycle 216 GMT 19/ 6/2024 9:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 34 14.86 397 201 0.20 / 865.63 2 2
2 7 2004.60 36 14.62 2889 1521 1.72 / 867.15 2 2
3 13 1520.40 21 14.63 2319 712 2.43 / 867.86 2 2
4 13 1001.44 21 14.67 1678 517 2.95 / 868.38 2 3
5 13 304.56 21 14.82 752 234 3.18 / 868.61 2 3
6 13 73.80 21 14.89 390 122 3.31 / 868.73 2 2
7 8 0.04 165 14.88 270 663 3.97 / 869.40 2 5
Average= 4.01
(KJ/cycle)

Cycle 215 GMT 9/ 6/2024 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 34 14.85 410 207 0.21 / 861.66 2 2
2 7 2004.64 36 14.63 2872 1513 1.72 / 863.17 2 2
3 13 1509.72 21 14.63 2329 716 2.44 / 863.89 2 2
4 13 996.40 21 14.67 1664 513 2.95 / 864.40 2 4
5 13 303.80 21 14.82 744 232 3.18 / 864.63 2 3
6 13 69.24 21 14.89 384 120 3.30 / 864.75 2 2
7 8 0.08 165 14.88 275 675 3.97 / 865.43 2 6
Average= 4.01
(KJ/cycle)

Cycle 214 GMT 30/ 5/2024 14:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 34 14.86 421 213 0.21 / 857.63 2 2
2 7 2010.48 36 14.62 2890 1521 1.73 / 859.15 2 3
3 13 1514.36 21 14.63 2338 718 2.45 / 859.87 2 3
4 13 999.84 21 14.66 1695 522 2.97 / 860.39 2 4
5 13 319.32 21 14.82 767 239 3.21 / 860.63 2 3
6 13 74.84 21 14.89 401 125 3.34 / 860.76 2 2
7 8 0.00 165 14.87 284 697 4.03 / 861.45 2 6
Average= 4.01
(KJ/cycle)

Cycle 213 GMT 20/ 5/2024 16:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 34 14.87 404 204 0.20 / 853.59 2 2
2 7 2009.16 36 14.63 2894 1524 1.73 / 855.11 2 3
3 13 1680.20 21 14.61 2524 774 2.50 / 855.88 2 2
4 13 962.92 21 14.67 1641 506 3.01 / 856.39 2 3
5 13 299.80 21 14.83 752 234 3.24 / 856.62 2 3
6 13 77.04 21 14.89 404 126 3.37 / 856.75 2 2
7 8 0.08 165 14.88 272 668 4.04 / 857.42 2 4
Average= 4.01
(KJ/cycle)

Cycle 212 GMT 10/ 5/2024 19: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 34 14.84 407 205 0.21 / 849.57 2 2
2 7 2012.68 36 14.62 2893 1523 1.73 / 851.10 2 2
3 13 1697.04 21 14.61 2537 778 2.51 / 851.87 2 2
4 13 968.96 21 14.67 1634 503 3.01 / 852.38 2 3
5 13 291.72 21 14.83 718 224 3.23 / 852.60 2 3
6 13 75.04 21 14.90 389 122 3.36 / 852.72 2 2
7 8 0.24 165 14.89 268 658 4.01 / 853.38 2 4
Average= 4.01
(KJ/cycle)

Cycle 211 GMT 30/ 4/2024 21:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 34 14.84 408 206 0.21 / 845.50 2 2
2 7 2012.44 37 14.62 2892 1564 1.77 / 847.06 2 2
3 13 1409.32 21 14.64 2176 669 2.44 / 847.73 2 2
4 13 919.36 21 14.68 1557 480 2.92 / 848.21 2 3
5 13 383.20 21 14.79 867 269 3.19 / 848.48 2 3
6 13 57.04 21 14.89 368 115 3.30 / 848.60 2 2
7 13 15.76 21 14.90 301 94 3.40 / 848.69 2 2
8 8 -0.04 165 14.87 275 675 4.07 / 849.37 2 5
Average= 4.01
(KJ/cycle)

Cycle 210 GMT 20/ 4/2024 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 34 14.85 415 210 0.21 / 841.41 2 2
2 7 2010.00 37 14.63 2871 1554 1.76 / 842.96 3 3
3 13 1508.76 21 14.63 2329 716 2.48 / 843.68 2 3
4 13 847.44 21 14.70 1478 456 2.94 / 844.13 2 4
5 13 333.80 21 14.81 801 249 3.18 / 844.38 2 3
6 13 82.80 21 14.89 413 129 3.31 / 844.51 2 2
7 13 20.00 21 14.90 314 98 3.41 / 844.61 2 2
8 8 0.08 165 14.86 280 687 4.10 / 845.29 2 5
Average= 4.01
(KJ/cycle)

Cycle 209 GMT 11/ 4/2024 2: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 34 14.84 406 205 0.20 / 837.31 2 2
2 7 2010.92 37 14.62 2883 1560 1.76 / 838.87 2 3
3 13 1531.92 21 14.62 2359 724 2.49 / 839.59 2 2
4 13 861.84 21 14.69 1505 464 2.95 / 840.06 2 3
5 13 347.28 21 14.80 819 255 3.21 / 840.31 2 3
6 13 83.28 21 14.89 401 125 3.33 / 840.44 2 2
7 13 23.60 21 14.90 312 98 3.43 / 840.54 2 2
8 8 0.04 165 14.87 269 660 4.09 / 841.20 2 3
Average= 4.01
(KJ/cycle)

Cycle 208 GMT 1/ 4/2024 4:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 34 14.85 404 204 0.20 / 833.25 2 2
2 7 2015.76 36 14.63 2890 1522 1.73 / 834.77 2 3
3 13 1526.96 21 14.64 2317 712 2.44 / 835.48 2 2
4 13 881.36 21 14.68 1530 472 2.91 / 835.95 2 3
5 13 366.88 21 14.80 845 263 3.17 / 836.22 2 3
6 13 89.60 21 14.88 409 128 3.30 / 836.35 2 2
7 13 22.16 21 14.90 306 96 3.40 / 836.44 2 2
8 8 0.04 165 14.87 271 665 4.06 / 837.11 2 3
Average= 4.01
(KJ/cycle)

Cycle 207 GMT 22/ 3/2024 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 34 14.85 414 209 0.21 / 829.11 2 2
2 7 2005.88 36 14.63 2878 1516 1.72 / 830.63 2 3
3 13 1689.28 21 14.61 2550 782 2.51 / 831.41 2 3
4 13 978.00 21 14.67 1633 503 3.01 / 831.91 2 4
5 13 305.32 21 14.82 751 234 3.24 / 832.15 2 3
6 13 87.84 21 14.89 404 126 3.37 / 832.27 2 2
7 13 48.04 21 14.89 345 108 3.48 / 832.38 2 2
8 8 0.16 165 14.87 271 665 4.14 / 833.04 2 5
Average= 4.01
(KJ/cycle)

Cycle 206 GMT 12/ 3/2024 8:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 34 14.85 405 204 0.20 / 825.03 2 2
2 7 2012.80 36 14.63 2885 1519 1.72 / 826.55 2 2
3 13 1533.24 21 14.63 2336 718 2.44 / 827.26 2 3
4 13 1009.56 21 14.66 1695 522 2.96 / 827.79 2 3
5 13 319.68 21 14.82 759 236 3.20 / 828.02 2 2
6 13 82.44 21 14.89 396 124 3.32 / 828.15 2 2
7 13 22.12 21 14.90 306 96 3.42 / 828.24 2 2
8 8 0.12 165 14.87 269 660 4.08 / 828.90 2 6
Average= 4.00
(KJ/cycle)

Cycle 205 GMT 2/ 3/2024 11:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 34 14.85 404 204 0.20 / 820.98 2 2
2 7 2008.00 36 14.63 2888 1521 1.73 / 822.50 2 2
3 13 1512.88 21 14.64 2308 710 2.43 / 823.21 2 2
4 13 993.20 21 14.67 1652 509 2.94 / 823.72 2 2
5 13 302.92 21 14.83 731 228 3.17 / 823.95 2 3
6 13 77.20 21 14.89 389 122 3.29 / 824.07 2 2
7 13 21.04 21 14.90 305 95 3.39 / 824.16 2 2
8 8 0.08 165 14.87 268 658 4.05 / 824.82 2 5
Average= 4.00
(KJ/cycle)

Cycle 204 GMT 21/ 2/2024 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 34 14.85 411 208 0.21 / 816.86 2 2
2 7 2021.04 37 14.62 2903 1570 1.78 / 818.43 2 2
3 13 1546.24 21 14.62 2379 730 2.51 / 819.16 2 2
4 13 890.60 21 14.69 1526 471 2.98 / 819.63 2 3
5 13 362.28 21 14.80 820 255 3.23 / 819.88 2 3
6 13 85.88 21 14.88 413 129 3.36 / 820.01 2 2
7 13 23.00 21 14.90 315 99 3.46 / 820.11 2 2
8 8 0.04 165 14.87 272 667 4.13 / 820.78 2 6
Average= 4.00
(KJ/cycle)

Cycle 203 GMT 11/ 2/2024 16: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 34 14.84 415 209 0.21 / 812.88 2 2
2 7 2013.08 36 14.63 2880 1517 1.73 / 814.40 2 2
3 13 1524.80 21 14.64 2331 717 2.44 / 815.12 2 3
4 13 846.40 21 14.70 1490 460 2.90 / 815.58 2 3
5 13 333.16 21 14.81 786 244 3.15 / 815.82 2 3
6 13 78.04 21 14.89 410 128 3.28 / 815.95 2 2
7 8 0.12 165 14.87 285 699 3.97 / 816.65 2 10
Average= 4.00
(KJ/cycle)

Cycle 202 GMT 1/ 2/2024 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 34 14.85 410 207 0.21 / 808.81 2 2
2 7 2011.92 36 14.63 2885 1519 1.73 / 810.33 2 3
3 13 1530.36 21 14.64 2326 715 2.44 / 811.04 2 2
4 13 878.20 21 14.70 1511 466 2.91 / 811.51 2 3
5 13 350.28 21 14.80 814 253 3.16 / 811.76 2 3
6 13 86.08 21 14.88 415 130 3.29 / 811.89 2 2
7 13 21.76 21 14.90 313 98 3.39 / 811.99 2 2
8 8 -0.04 165 14.86 278 682 4.07 / 812.67 2 5
Average= 4.00
(KJ/cycle)

Cycle 201 GMT 22/ 1/2024 20:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 34 14.84 414 209 0.21 / 804.71 2 2
2 7 2003.80 37 14.63 2893 1566 1.77 / 806.27 2 2
3 13 1494.48 21 14.65 2294 706 2.48 / 806.98 2 2
4 13 973.32 21 14.68 1643 507 2.99 / 807.48 2 3
5 13 297.68 21 14.83 734 229 3.22 / 807.71 2 3
6 13 74.60 21 14.89 395 124 3.34 / 807.84 2 2
7 13 18.52 21 14.90 303 95 3.43 / 807.93 2 2
8 8 0.08 165 14.87 274 672 4.11 / 808.60 2 4
Average= 4.00
(KJ/cycle)

Cycle 200 GMT 12/ 1/2024 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 34 14.84 418 211 0.21 / 800.61 2 2
2 7 2015.08 36 14.63 2899 1527 1.74 / 802.14 2 2
3 13 1535.24 21 14.63 2363 726 2.46 / 802.86 2 2
4 13 867.76 21 14.70 1506 465 2.93 / 803.33 2 3
5 13 347.16 21 14.81 804 250 3.18 / 803.58 2 3
6 13 83.96 21 14.89 408 128 3.31 / 803.70 2 2
7 13 20.40 21 14.90 313 98 3.40 / 803.80 2 2
8 8 0.00 165 14.87 283 694 4.10 / 804.50 2 7
Average= 4.00
(KJ/cycle)

Cycle 199 GMT 3/ 1/2024 1:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 34 14.83 423 213 0.21 / 796.48 2 2
2 7 2009.24 36 14.63 2900 1527 1.74 / 798.00 2 2
3 13 1521.52 21 14.65 2322 714 2.46 / 798.72 2 2
4 13 995.28 21 14.68 1663 513 2.97 / 799.23 2 4
5 13 303.32 21 14.82 766 238 3.21 / 799.47 2 3
6 13 73.64 21 14.89 404 126 3.33 / 799.59 2 2
7 13 20.16 21 14.90 331 104 3.44 / 799.70 2 2
8 8 0.16 165 14.87 285 699 4.14 / 800.40 2 4
Average= 4.00
(KJ/cycle)

Cycle 198 GMT 24/12/2023 3:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 34 14.84 410 207 0.21 / 792.35 2 2
2 7 2003.76 36 14.63 2896 1525 1.73 / 793.87 2 3
3 13 1528.52 21 14.63 2363 726 2.46 / 794.60 2 2
4 13 867.84 21 14.70 1493 461 2.92 / 795.06 2 3
5 13 353.76 21 14.80 835 260 3.18 / 795.32 2 3
6 13 89.76 21 14.88 437 137 3.32 / 795.46 2 2
7 13 20.64 21 14.89 336 105 3.42 / 795.56 2 2
8 8 0.12 165 14.86 286 701 4.12 / 796.26 2 5
Average= 4.00
(KJ/cycle)

Cycle 197 GMT 14/12/2023 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 34 14.85 397 200 0.20 / 788.25 2 2
2 7 2008.24 36 14.64 2882 1519 1.72 / 789.77 2 2
3 13 1539.44 21 14.64 2335 718 2.44 / 790.49 2 2
4 13 886.28 21 14.69 1536 474 2.91 / 790.96 2 4
5 13 368.72 21 14.80 840 261 3.17 / 791.22 2 3
6 13 92.44 21 14.88 428 134 3.31 / 791.36 2 2
7 13 19.00 21 14.90 324 101 3.41 / 791.46 2 2
8 8 0.00 165 14.87 278 682 4.09 / 792.14 2 4
Average= 4.00
(KJ/cycle)

Cycle 196 GMT 4/12/2023 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 34 14.84 410 207 0.21 / 784.20 2 2
2 7 2005.04 36 14.64 2883 1519 1.73 / 785.72 2 2
3 13 1516.04 21 14.65 2311 711 2.44 / 786.43 2 2
4 13 865.60 21 14.71 1501 464 2.90 / 786.90 2 2
5 13 350.04 21 14.81 817 254 3.16 / 787.15 2 3
6 13 84.16 21 14.89 409 128 3.28 / 787.28 2 2
7 13 15.16 21 14.90 309 97 3.38 / 787.37 2 2
8 8 -0.04 165 14.87 276 677 4.06 / 788.05 2 5
Average= 4.00
(KJ/cycle)

Cycle 195 GMT 24/11/2023 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 34 14.86 405 205 0.20 / 780.12 2 2
2 7 2004.96 37 14.64 2885 1563 1.77 / 781.68 2 3
3 13 1516.92 21 14.64 2339 719 2.49 / 782.40 2 2
4 13 860.44 21 14.71 1494 462 2.95 / 782.86 2 4
5 13 332.60 21 14.82 779 242 3.19 / 783.10 2 2
6 13 75.32 21 14.89 394 123 3.31 / 783.23 2 2
7 13 16.76 21 14.90 308 96 3.41 / 783.32 2 2
8 8 0.00 165 14.87 274 672 4.08 / 783.99 2 8
Average= 4.00
(KJ/cycle)

Cycle 194 GMT 14/11/2023 13: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 33 14.86 400 196 0.20 / 776.14 2 2
2 7 2004.48 36 14.64 2896 1526 1.72 / 777.67 2 2
3 13 1517.24 21 14.65 2318 713 2.44 / 778.38 2 2
4 13 1003.48 21 14.68 1678 517 2.95 / 778.90 2 3
5 13 302.44 21 14.83 742 231 3.18 / 779.13 2 3
6 13 75.60 21 14.89 390 122 3.31 / 779.25 2 2
7 8 0.08 165 14.88 270 663 3.97 / 779.91 2 3
Average= 4.00
(KJ/cycle)

Cycle 193 GMT 4/11/2023 15:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 33 14.85 413 202 0.20 / 772.11 2 2
2 7 2013.48 37 14.64 2889 1565 1.77 / 773.68 2 3
3 13 1530.48 21 14.64 2350 722 2.49 / 774.40 2 2
4 13 1014.52 21 14.67 1681 518 3.01 / 774.92 2 3
5 13 305.68 21 14.83 744 232 3.24 / 775.15 2 3
6 13 79.16 21 14.89 399 125 3.36 / 775.28 2 2
7 8 0.04 165 14.88 272 668 4.03 / 775.94 2 3
Average= 4.00
(KJ/cycle)

Cycle 192 GMT 25/10/2023 17:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 33 14.85 413 202 0.20 / 768.18 2 2
2 7 2008.08 36 14.64 2874 1515 1.72 / 769.69 2 3
3 13 1511.76 21 14.65 2317 713 2.43 / 770.41 2 2
4 13 849.44 21 14.71 1472 455 2.88 / 770.86 2 4
5 13 340.08 21 14.82 794 247 3.13 / 771.11 2 3
6 13 79.88 21 14.89 412 129 3.26 / 771.24 2 2
7 8 -0.04 165 14.88 275 675 3.94 / 771.91 2 4
Average= 4.00
(KJ/cycle)

Cycle 191 GMT 15/10/2023 20:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 34 14.85 409 207 0.21 / 764.21 2 2
2 7 2009.92 36 14.64 2883 1519 1.73 / 765.73 2 3
3 13 1499.84 21 14.65 2313 712 2.44 / 766.44 2 3
4 13 985.36 21 14.68 1661 512 2.95 / 766.96 2 3
5 13 292.92 21 14.83 742 231 3.18 / 767.19 2 3
6 13 76.52 21 14.89 390 122 3.30 / 767.31 2 2
7 8 0.12 165 14.88 272 668 3.97 / 767.98 2 4
Average= 4.00
(KJ/cycle)

Cycle 190 GMT 5/10/2023 22:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 33 14.85 407 199 0.20 / 760.24 2 2
2 7 2012.08 36 14.64 2883 1519 1.72 / 761.76 2 3
3 13 1534.76 21 14.64 2336 718 2.44 / 762.48 2 2
4 13 997.00 21 14.68 1658 511 2.95 / 762.99 2 2
5 13 288.32 21 14.83 723 225 3.17 / 763.21 2 3
6 13 78.96 21 14.89 395 124 3.30 / 763.34 2 2
7 8 0.16 165 14.88 272 668 3.96 / 764.01 2 6
Average= 4.00
(KJ/cycle)

Cycle 189 GMT 26/ 9/2023 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 33 14.86 406 199 0.20 / 756.23 2 2
2 7 2013.12 36 14.64 2884 1520 1.72 / 757.75 2 3
3 13 1527.60 21 14.64 2345 721 2.44 / 758.47 2 2
4 13 1011.44 21 14.67 1704 525 2.96 / 759.00 2 3
5 13 304.36 21 14.82 761 237 3.20 / 759.23 2 2
6 13 75.68 21 14.89 403 126 3.33 / 759.36 2 2
7 8 0.08 165 14.87 278 682 4.01 / 760.04 2 7
Average= 4.00
(KJ/cycle)

Cycle 188 GMT 16/ 9/2023 3:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 33 14.85 416 204 0.20 / 752.16 2 2
2 7 2004.40 37 14.65 2876 1559 1.76 / 753.72 2 2
3 13 1671.64 21 14.63 2501 768 2.53 / 754.49 2 2
4 13 955.08 21 14.69 1632 503 3.03 / 754.99 2 4
5 13 290.76 21 14.83 747 233 3.27 / 755.23 2 2
6 13 91.76 21 14.90 419 131 3.40 / 755.36 2 2
7 8 0.04 165 14.89 274 673 4.07 / 756.03 2 3
Average= 4.00
(KJ/cycle)

Cycle 187 GMT 6/ 9/2023 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 33 14.85 411 201 0.20 / 748.11 2 2
2 7 2014.20 36 14.64 2904 1531 1.73 / 749.64 2 3
3 13 1692.44 21 14.63 2531 778 2.51 / 750.42 2 3
4 13 983.56 21 14.69 1640 506 3.02 / 750.92 2 4
5 13 300.84 21 14.83 752 234 3.25 / 751.16 2 3
6 13 76.96 21 14.89 400 125 3.37 / 751.28 2 2
7 8 0.12 165 14.88 276 678 4.05 / 751.96 2 5
Average= 4.00
(KJ/cycle)

Cycle 186 GMT 27/ 8/2023 8: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 33 14.85 406 199 0.20 / 744.12 2 2
2 7 2009.72 36 14.65 2893 1526 1.72 / 745.64 2 2
3 13 1533.36 21 14.64 2340 719 2.44 / 746.36 2 2
4 13 881.44 21 14.70 1537 474 2.92 / 746.84 2 2
5 13 345.00 21 14.81 830 258 3.18 / 747.09 2 3
6 13 88.52 21 14.89 419 131 3.31 / 747.22 2 2
7 8 0.00 165 14.88 278 683 3.99 / 747.91 2 7
Average= 4.00
(KJ/cycle)

Cycle 185 GMT 17/ 8/2023 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 33 14.85 413 202 0.20 / 740.13 2 2
2 7 2004.08 37 14.65 2877 1559 1.76 / 741.69 2 2
3 13 1524.96 21 14.66 2318 714 2.48 / 742.41 2 2
4 13 869.56 21 14.71 1495 462 2.94 / 742.87 2 4
5 13 344.92 21 14.82 797 248 3.19 / 743.12 2 3
6 13 87.48 21 14.89 415 130 3.32 / 743.25 2 2
7 8 0.04 165 14.88 273 670 3.99 / 743.92 2 3
Average= 4.00
(KJ/cycle)

Cycle 184 GMT 7/ 8/2023 12:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 33 14.85 401 197 0.20 / 736.20 2 2
2 7 2012.28 36 14.65 2875 1516 1.71 / 737.72 3 3
3 13 1516.56 21 14.66 2312 712 2.42 / 738.43 2 2
4 13 850.48 21 14.72 1474 456 2.88 / 738.89 2 3
5 13 326.48 21 14.82 777 242 3.12 / 739.13 2 3
6 13 83.56 21 14.89 403 126 3.25 / 739.25 2 2
7 8 0.04 165 14.88 276 678 3.93 / 739.93 2 6
Average= 4.00
(KJ/cycle)

Cycle 183 GMT 28/ 7/2023 14:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 33 14.86 397 195 0.19 / 732.24 2 2
2 7 2011.96 36 14.65 2892 1525 1.72 / 733.76 2 2
3 13 1535.48 21 14.65 2341 720 2.44 / 734.48 2 2
4 13 994.28 21 14.69 1654 510 2.95 / 734.99 2 3
5 13 291.36 21 14.84 722 225 3.18 / 735.22 2 2
6 13 79.24 21 14.90 394 123 3.30 / 735.34 2 2
7 8 0.16 165 14.88 271 665 3.96 / 736.01 2 5
Average= 4.00
(KJ/cycle)

Cycle 182 GMT 18/ 7/2023 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 33 14.86 414 203 0.20 / 728.28 2 2
2 7 2005.20 36 14.65 2879 1518 1.72 / 729.79 2 2
3 13 1533.72 21 14.66 2322 715 2.44 / 730.51 2 2
4 13 1011.20 21 14.68 1673 516 2.95 / 731.02 2 4
5 13 317.80 21 14.83 752 234 3.19 / 731.26 2 3
6 13 82.92 21 14.89 398 124 3.31 / 731.38 2 2
7 8 0.12 165 14.89 268 658 3.97 / 732.04 2 4
Average= 4.00
(KJ/cycle)

Cycle 181 GMT 8/ 7/2023 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 33 14.85 408 200 0.20 / 724.27 2 2
2 7 2004.84 36 14.65 2883 1520 1.72 / 725.79 2 2
3 13 1677.92 21 14.64 2516 774 2.49 / 726.56 2 3
4 13 961.48 21 14.70 1629 503 3.00 / 727.07 2 2
5 13 290.84 21 14.84 717 223 3.22 / 727.29 2 3
6 13 74.28 21 14.90 386 121 3.34 / 727.41 2 2
7 8 0.04 165 14.89 269 661 4.00 / 728.07 2 4
Average= 4.00
(KJ/cycle)

Cycle 180 GMT 28/ 6/2023 21:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 33 14.85 413 202 0.20 / 720.31 2 2
2 7 2012.44 36 14.65 2897 1528 1.73 / 721.84 2 3
3 13 1520.04 21 14.66 2321 715 2.44 / 722.55 2 2
4 13 870.16 21 14.71 1519 469 2.91 / 723.02 2 2
5 13 339.56 21 14.82 797 248 3.16 / 723.27 2 2
6 13 88.32 21 14.89 411 129 3.29 / 723.40 2 2
7 8 0.20 165 14.88 273 670 3.96 / 724.07 2 4
Average= 4.00
(KJ/cycle)

Cycle 179 GMT 19/ 6/2023 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 33 14.86 409 201 0.20 / 716.25 2 2
2 7 2015.52 37 14.65 2897 1570 1.77 / 717.82 2 3
3 13 1544.48 21 14.65 2340 720 2.49 / 718.54 2 2
4 13 883.92 21 14.71 1517 469 2.96 / 719.01 2 3
5 13 364.64 21 14.81 835 260 3.22 / 719.27 2 3
6 13 85.80 21 14.89 435 136 3.36 / 719.41 2 2
7 8 0.08 165 14.87 287 704 4.06 / 720.11 2 5
Average= 4.00
(KJ/cycle)

Cycle 178 GMT 9/ 6/2023 2:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 33 14.87 404 198 0.20 / 712.27 2 2
2 7 2003.20 36 14.66 2882 1521 1.72 / 713.79 2 2
3 13 1521.52 21 14.67 2322 715 2.43 / 714.51 2 2
4 13 985.16 21 14.70 1647 508 2.94 / 715.02 2 4
5 13 292.56 21 14.84 732 228 3.17 / 715.24 2 3
6 13 76.28 21 14.90 394 123 3.29 / 715.37 2 2
7 8 0.04 165 14.88 278 683 3.98 / 716.05 2 5
Average= 4.00
(KJ/cycle)

Cycle 177 GMT 30/ 5/2023 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 33 14.85 410 201 0.20 / 708.30 2 2
2 7 2003.80 36 14.65 2892 1525 1.73 / 709.83 2 3
3 13 1513.44 21 14.67 2318 714 2.44 / 710.54 2 3
4 13 999.12 21 14.69 1691 522 2.96 / 711.06 2 3
5 13 297.92 21 14.84 726 226 3.19 / 711.29 2 3
6 13 79.60 21 14.90 392 123 3.31 / 711.41 2 2
7 8 0.00 165 14.89 269 661 3.97 / 712.07 2 3
Average= 4.00
(KJ/cycle)

Cycle 176 GMT 20/ 5/2023 7:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 33 14.87 401 197 0.20 / 704.35 2 2
2 7 2008.44 36 14.66 2879 1519 1.72 / 705.87 2 3
3 13 1524.72 21 14.66 2325 716 2.43 / 706.58 2 3
4 13 850.52 21 14.72 1474 456 2.89 / 707.04 2 3
5 13 334.72 21 14.82 805 251 3.14 / 707.29 2 3
6 13 80.56 21 14.89 412 129 3.27 / 707.42 2 2
7 8 0.04 165 14.88 278 683 3.95 / 708.10 2 5
Average= 4.00
(KJ/cycle)

Cycle 175 GMT 10/ 5/2023 9:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 33 14.86 410 201 0.20 / 700.35 2 2
2 7 2011.40 36 14.66 2890 1525 1.73 / 701.87 2 2
3 13 1683.36 21 14.64 2510 772 2.50 / 702.64 2 3
4 13 952.80 21 14.71 1599 494 2.99 / 703.14 2 3
5 13 290.24 21 14.84 726 226 3.22 / 703.36 2 3
6 13 80.28 21 14.90 396 124 3.34 / 703.49 2 2
7 8 0.12 165 14.89 271 666 4.01 / 704.15 2 4
Average= 4.00
(KJ/cycle)

Cycle 174 GMT 30/ 4/2023 11:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 33 14.86 414 203 0.20 / 696.30 2 2
2 7 2006.04 36 14.66 2890 1525 1.73 / 697.83 2 3
3 13 1683.04 21 14.64 2532 778 2.51 / 698.61 2 3
4 13 971.52 21 14.70 1648 509 3.02 / 699.11 2 3
5 13 292.76 21 14.84 732 228 3.24 / 699.34 2 3
6 13 78.88 21 14.91 396 124 3.37 / 699.47 2 2
7 8 0.12 165 14.89 276 678 4.05 / 700.14 2 3
Average= 4.00
(KJ/cycle)

Cycle 173 GMT 20/ 4/2023 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 33 14.86 414 203 0.20 / 692.40 2 2
2 7 2004.16 36 14.66 2867 1513 1.72 / 693.91 2 3
3 13 1498.72 21 14.67 2300 709 2.42 / 694.62 2 2
4 13 836.68 21 14.73 1476 457 2.88 / 695.08 2 3
5 13 329.00 21 14.83 771 240 3.12 / 695.32 2 3
6 13 84.68 21 14.90 399 125 3.25 / 695.44 2 2
7 8 0.04 165 14.89 268 658 3.90 / 696.10 2 6
Average= 4.00
(KJ/cycle)

Cycle 172 GMT 10/ 4/2023 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 34 14.86 405 205 0.20 / 688.33 2 2
2 7 2004.60 36 14.66 2890 1525 1.73 / 689.85 2 2
3 13 1677.16 21 14.64 2505 770 2.50 / 690.62 2 3
4 13 942.44 21 14.71 1594 492 2.99 / 691.12 2 4
5 13 414.36 21 14.80 900 280 3.27 / 691.40 2 3
6 13 108.28 21 14.89 441 138 3.41 / 691.53 2 2
7 8 0.00 165 14.89 269 661 4.07 / 692.19 2 4
Average= 4.00
(KJ/cycle)

Cycle 171 GMT 31/ 3/2023 18:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 34 14.86 410 207 0.21 / 684.25 2 2
2 7 2017.28 36 14.65 2904 1532 1.74 / 685.78 2 3
3 13 1530.20 21 14.66 2336 719 2.46 / 686.50 2 2
4 13 999.96 21 14.70 1666 514 2.97 / 687.01 2 2
5 13 310.48 21 14.84 743 232 3.20 / 687.25 2 2
6 13 83.56 21 14.90 391 122 3.33 / 687.37 2 2
7 13 46.24 21 14.90 335 105 3.43 / 687.47 2 2
8 8 0.04 165 14.88 265 651 4.08 / 688.12 2 6
Average= 4.00
(KJ/cycle)

Cycle 170 GMT 21/ 3/2023 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 34 14.87 399 202 0.20 / 680.20 2 2
2 7 2008.40 37 14.65 2884 1563 1.76 / 681.76 2 3
3 13 1537.16 21 14.66 2333 718 2.48 / 682.48 2 3
4 13 1019.52 21 14.69 1722 531 3.01 / 683.01 2 3
5 13 321.80 21 14.83 764 238 3.25 / 683.25 2 3
6 13 88.48 21 14.90 403 126 3.38 / 683.38 2 2
7 8 0.04 165 14.89 270 663 4.04 / 684.04 2 4
Average= 4.00
(KJ/cycle)

Cycle 169 GMT 11/ 3/2023 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 34 14.86 413 209 0.21 / 676.24 2 2
2 7 2012.88 36 14.66 2887 1524 1.73 / 677.77 2 3
3 13 1517.16 21 14.66 2324 715 2.45 / 678.48 2 2
4 13 875.64 21 14.72 1519 470 2.92 / 678.95 2 3
5 13 354.60 21 14.82 815 254 3.17 / 679.20 2 3
6 13 95.56 21 14.90 415 130 3.30 / 679.33 2 2
7 8 0.12 165 14.89 271 666 3.97 / 680.00 2 5
Average= 4.00
(KJ/cycle)

Cycle 168 GMT 2/ 3/2023 2: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 33 14.87 406 199 0.20 / 672.28 2 2
2 7 2013.36 36 14.66 2882 1521 1.72 / 673.80 2 3
3 13 1530.44 21 14.66 2336 719 2.44 / 674.52 2 3
4 13 874.68 21 14.72 1512 467 2.91 / 674.99 2 3
5 13 359.64 21 14.82 824 256 3.16 / 675.25 2 3
6 13 105.20 21 14.89 431 135 3.30 / 675.38 2 2
7 8 0.08 165 14.89 265 651 3.95 / 676.03 2 5
Average= 4.00
(KJ/cycle)

Cycle 167 GMT 20/ 2/2023 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 33 14.87 405 199 0.20 / 668.26 2 2
2 7 2003.44 36 14.66 2885 1523 1.72 / 669.78 2 2
3 13 1512.04 21 14.68 2304 710 2.43 / 670.49 2 2
4 13 986.36 21 14.71 1646 508 2.94 / 671.00 2 2
5 13 289.28 21 14.85 712 222 3.16 / 671.23 2 2
6 13 83.04 21 14.91 393 123 3.29 / 671.35 2 2
7 13 20.52 21 14.92 295 92 3.38 / 671.44 2 2
8 8 0.04 165 14.89 262 644 4.02 / 672.08 2 4
Average= 4.00
(KJ/cycle)

Cycle 166 GMT 10/ 2/2023 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 33 14.88 397 195 0.19 / 664.28 2 2
2 7 2004.76 36 14.66 2886 1523 1.72 / 665.80 2 2
3 13 1672.24 21 14.65 2514 773 2.49 / 666.58 2 3
4 13 954.96 21 14.72 1602 495 2.99 / 667.07 2 2
5 13 277.88 21 14.85 691 215 3.20 / 667.29 2 3
6 13 78.08 21 14.91 387 121 3.32 / 667.41 2 2
7 8 0.00 165 14.90 266 654 3.98 / 668.06 2 3
Average= 4.00
(KJ/cycle)

Cycle 165 GMT 31/ 1/2023 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 33 14.87 407 200 0.20 / 660.28 2 2
2 7 2004.96 36 14.67 2879 1520 1.72 / 661.81 2 2
3 13 1533.48 21 14.67 2335 719 2.44 / 662.52 2 3
4 13 1012.64 21 14.70 1698 524 2.96 / 663.05 2 4
5 13 339.60 21 14.83 799 249 3.21 / 663.30 2 3
6 13 105.24 21 14.90 428 134 3.35 / 663.43 2 2
7 8 0.08 165 14.90 266 654 4.00 / 664.09 2 3
Average= 4.00
(KJ/cycle)

Cycle 164 GMT 21/ 1/2023 11:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 33 14.87 409 201 0.20 / 656.32 2 2
2 7 2003.76 36 14.67 2883 1523 1.72 / 657.85 2 3
3 13 1534.24 21 14.66 2358 726 2.45 / 658.57 2 3
4 13 860.92 21 14.72 1509 466 2.92 / 659.04 2 4
5 13 347.00 21 14.83 806 251 3.17 / 659.29 2 3
6 13 98.28 21 14.90 424 133 3.30 / 659.42 2 2
7 8 0.04 165 14.89 270 663 3.96 / 660.09 2 4
Average= 4.00
(KJ/cycle)

Cycle 163 GMT 11/ 1/2023 13:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 33 14.87 404 198 0.20 / 652.32 2 2
2 7 2010.92 36 14.67 2896 1529 1.73 / 653.85 2 3
3 13 1523.92 21 14.67 2326 717 2.44 / 654.56 2 3
4 13 1006.60 21 14.70 1693 523 2.97 / 655.08 2 5
5 13 315.32 21 14.84 764 238 3.20 / 655.32 2 3
6 13 90.56 21 14.91 411 129 3.33 / 655.45 2 2
7 8 0.08 165 14.89 273 671 4.00 / 656.12 2 3
Average= 4.00
(KJ/cycle)

Cycle 162 GMT 1/ 1/2023 15:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 33 14.87 401 197 0.20 / 648.35 2 2
2 7 2008.20 36 14.66 2889 1525 1.72 / 649.88 2 2
3 13 1539.32 21 14.66 2343 721 2.44 / 650.60 2 2
4 13 878.68 21 14.73 1516 469 2.91 / 651.07 2 4
5 13 361.84 21 14.82 827 257 3.17 / 651.32 2 3
6 13 101.28 21 14.90 427 134 3.30 / 651.46 2 2
7 8 0.00 165 14.89 269 661 3.96 / 652.12 2 6
Average= 4.00
(KJ/cycle)

Cycle 161 GMT 22/12/2022 17:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 33 14.88 413 203 0.20 / 644.35 2 2
2 7 2006.16 36 14.67 2881 1522 1.72 / 645.88 2 2
3 13 1490.84 21 14.68 2290 706 2.43 / 646.58 2 3
4 13 835.84 21 14.74 1463 453 2.88 / 647.03 2 2
5 13 329.20 21 14.84 774 241 3.12 / 647.28 2 3
6 13 92.72 21 14.91 414 130 3.25 / 647.41 2 2
7 13 22.32 21 14.92 306 96 3.35 / 647.50 2 2
8 8 0.04 165 14.89 266 654 4.00 / 648.15 2 4
Average= 4.00
(KJ/cycle)

Cycle 160 GMT 12/12/2022 20: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 33 14.87 411 202 0.20 / 640.38 2 2
2 7 2005.12 36 14.67 2899 1531 1.73 / 641.91 2 2
3 13 1505.68 21 14.68 2306 711 2.44 / 642.62 2 2
4 13 982.24 21 14.72 1650 510 2.95 / 643.13 2 3
5 13 301.28 21 14.85 737 230 3.18 / 643.36 2 2
6 13 84.36 21 14.91 402 126 3.31 / 643.49 2 2
7 8 0.00 165 14.90 270 664 3.97 / 644.15 2 6
Average= 4.00
(KJ/cycle)

Cycle 159 GMT 2/12/2022 22:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 33 14.87 417 205 0.20 / 636.15 2 2
2 7 2005.28 36 14.67 2889 1526 1.73 / 637.68 2 3
3 13 1670.72 21 14.66 2510 773 2.50 / 638.45 2 2
4 13 973.48 21 14.72 1639 507 3.01 / 638.96 2 2
5 13 441.84 21 14.81 938 292 3.30 / 639.25 2 3
6 13 123.04 21 14.90 473 148 3.45 / 639.40 2 2
7 13 22.60 21 14.92 323 101 3.55 / 639.50 2 2
8 8 0.04 165 14.89 276 678 4.23 / 640.18 2 6
Average= 4.00
(KJ/cycle)

Cycle 158 GMT 23/11/2022 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 33 14.88 411 202 0.20 / 632.09 2 2
2 7 2007.52 37 14.67 2884 1565 1.77 / 633.66 2 2
3 13 1532.36 21 14.67 2342 721 2.49 / 634.38 2 2
4 13 1025.48 21 14.70 1698 524 3.01 / 634.90 2 4
5 13 324.80 21 14.84 767 239 3.25 / 635.14 2 2
6 13 90.20 21 14.91 410 128 3.38 / 635.27 2 2
7 8 0.08 165 14.90 277 681 4.06 / 635.95 2 4
Average= 4.00
(KJ/cycle)

Cycle 157 GMT 13/11/2022 3:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 33 14.88 403 198 0.20 / 628.04 2 2
2 7 2007.96 36 14.67 2888 1525 1.72 / 629.57 2 3
3 13 1687.84 21 14.65 2554 786 2.51 / 630.35 2 3
4 13 993.64 21 14.72 1660 513 3.02 / 630.87 2 2
5 13 306.20 21 14.85 742 231 3.25 / 631.10 2 3
6 13 88.80 21 14.91 406 127 3.38 / 631.23 2 2
7 8 0.12 165 14.91 269 662 4.04 / 631.89 2 4
Average= 4.00
(KJ/cycle)

Cycle 156 GMT 3/11/2022 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 33 14.87 420 206 0.21 / 624.04 2 2
2 7 2008.32 36 14.66 2895 1528 1.73 / 625.57 2 3
3 13 1545.56 21 14.66 2379 732 2.47 / 626.30 2 2
4 13 1009.28 21 14.71 1692 523 2.99 / 626.83 2 3
5 13 296.48 21 14.86 732 228 3.22 / 627.06 2 3
6 13 80.12 21 14.92 395 124 3.34 / 627.18 2 2
7 8 0.08 165 14.90 271 666 4.01 / 627.85 2 4
Average= 4.00
(KJ/cycle)

Cycle 155 GMT 24/10/2022 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 33 14.88 407 200 0.20 / 619.98 2 2
2 7 2005.56 36 14.67 2869 1515 1.72 / 621.50 2 2
3 13 1685.92 21 14.66 2513 774 2.49 / 622.27 2 3
4 13 989.40 21 14.71 1678 518 3.01 / 622.79 2 3
5 13 301.72 21 14.85 745 232 3.24 / 623.02 2 2
6 13 82.96 21 14.91 405 127 3.37 / 623.15 2 2
7 8 0.04 165 14.90 281 691 4.06 / 623.84 2 4
Average= 4.00
(KJ/cycle)

Cycle 154 GMT 14/10/2022 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 33 14.88 409 201 0.20 / 615.99 2 2
2 7 2012.16 36 14.67 2903 1533 1.73 / 617.52 2 2
3 13 1513.28 21 14.68 2322 716 2.45 / 618.24 2 2
4 13 1000.08 21 14.72 1675 518 2.97 / 618.75 2 3
5 13 300.32 21 14.85 739 230 3.20 / 618.98 2 2
6 13 83.88 21 14.92 400 125 3.32 / 619.11 2 2
7 8 0.04 165 14.91 273 672 3.99 / 619.78 2 3
Average= 4.00
(KJ/cycle)

Cycle 153 GMT 4/10/2022 12:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 33 14.88 422 207 0.21 / 611.99 2 2
2 7 2004.32 36 14.68 2867 1515 1.72 / 613.50 2 3
3 13 1520.96 21 14.69 2299 709 2.43 / 614.21 2 2
4 13 996.24 21 14.72 1679 519 2.95 / 614.73 2 2
5 13 319.52 21 14.85 775 242 3.19 / 614.97 2 2
6 13 83.36 21 14.91 418 131 3.32 / 615.11 2 2
7 8 -0.04 165 14.90 277 681 4.00 / 615.79 2 4
Average= 4.00
(KJ/cycle)

Cycle 152 GMT 24/ 9/2022 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 33 14.87 422 207 0.21 / 608.01 2 2
2 7 2005.80 36 14.68 2876 1520 1.73 / 609.53 2 2
3 13 1536.68 21 14.68 2313 713 2.44 / 610.24 2 2
4 13 997.12 21 14.72 1655 512 2.95 / 610.75 2 2
5 13 303.32 21 14.86 735 229 3.18 / 610.98 2 3
6 13 76.72 21 14.92 391 123 3.30 / 611.10 2 2
7 8 0.08 165 14.91 276 679 3.98 / 611.78 2 6
Average= 4.00
(KJ/cycle)

Cycle 151 GMT 14/ 9/2022 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 33 14.89 400 197 0.20 / 603.97 2 2
2 7 2016.32 36 14.67 2897 1530 1.73 / 605.50 2 2
3 13 1694.92 21 14.66 2534 780 2.51 / 606.28 2 3
4 13 844.56 21 14.74 1498 464 2.97 / 606.75 2 3
5 13 345.36 21 14.84 797 248 3.22 / 607.00 2 3
6 13 81.28 21 14.92 399 125 3.34 / 607.12 2 2
7 8 0.04 165 14.90 276 679 4.02 / 607.80 2 4
Average= 4.00
(KJ/cycle)

Cycle 150 GMT 4/ 9/2022 19: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 33 14.89 415 204 0.20 / 599.98 2 2
2 7 2011.48 36 14.67 2902 1533 1.74 / 601.51 2 3
3 13 1520.36 21 14.68 2334 720 2.46 / 602.23 2 2
4 13 994.24 21 14.72 1678 519 2.97 / 602.75 2 3
5 13 294.44 21 14.86 757 236 3.21 / 602.99 2 2
6 13 83.00 21 14.92 396 124 3.34 / 603.11 2 2
7 8 0.04 165 14.91 271 667 4.00 / 603.78 2 4
Average= 4.00
(KJ/cycle)

Cycle 149 GMT 25/ 8/2022 21:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 33 14.88 416 204 0.20 / 596.11 2 2
2 7 2009.40 36 14.68 2888 1526 1.73 / 597.63 2 2
3 13 1391.04 21 14.70 2160 667 2.40 / 598.30 2 2
4 13 924.60 21 14.73 1559 482 2.88 / 598.78 2 3
5 13 246.52 21 14.88 651 203 3.08 / 598.99 2 3
6 13 70.72 21 14.93 378 119 3.20 / 599.10 2 2
7 8 0.12 165 14.91 273 672 3.87 / 599.78 2 6
Average= 4.00
(KJ/cycle)

Cycle 148 GMT 15/ 8/2022 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 33 14.89 407 200 0.20 / 592.08 2 2
2 7 2005.08 37 14.68 2882 1565 1.77 / 593.65 2 2
3 13 1532.56 21 14.68 2331 719 2.48 / 594.37 2 3
4 13 871.24 21 14.75 1500 465 2.95 / 594.83 2 3
5 13 354.80 21 14.84 810 252 3.20 / 595.08 2 3
6 13 91.52 21 14.92 424 133 3.33 / 595.22 2 2
7 8 0.12 165 14.91 279 686 4.02 / 595.90 2 3
Average= 4.00
(KJ/cycle)

Cycle 147 GMT 6/ 8/2022 1:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 33 14.89 409 201 0.20 / 588.12 2 2
2 7 2003.84 36 14.68 2872 1518 1.72 / 589.64 2 3
3 13 1509.48 21 14.69 2302 710 2.43 / 590.35 2 3
4 13 980.32 21 14.73 1650 510 2.94 / 590.86 2 3
5 13 282.88 21 14.87 723 226 3.17 / 591.09 2 3
6 13 78.72 21 14.93 396 124 3.29 / 591.21 2 2
7 8 0.04 165 14.92 273 672 3.96 / 591.88 2 4
Average= 4.00
(KJ/cycle)

Cycle 146 GMT 27/ 7/2022 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 33 14.89 411 202 0.20 / 584.05 2 2
2 7 2006.00 36 14.68 2885 1525 1.73 / 585.58 2 3
3 13 1684.68 21 14.66 2534 780 2.51 / 586.36 2 3
4 13 947.44 21 14.73 1615 500 3.01 / 586.85 2 4
5 13 405.56 21 14.83 902 281 3.29 / 587.14 2 3
6 13 73.24 21 14.93 384 120 3.41 / 587.26 2 2
7 8 0.04 165 14.92 270 665 4.07 / 587.92 2 5
Average= 4.00
(KJ/cycle)

Cycle 145 GMT 17/ 7/2022 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 33 14.88 424 208 0.21 / 580.03 2 2
2 7 2004.44 36 14.68 2875 1519 1.73 / 581.55 2 2
3 13 1541.00 21 14.69 2348 724 2.45 / 582.28 2 3
4 13 1027.40 21 14.71 1727 533 2.99 / 582.81 2 3
5 13 317.60 21 14.86 759 237 3.22 / 583.05 2 3
6 13 84.56 21 14.92 402 126 3.35 / 583.17 2 2
7 8 0.12 165 14.92 274 675 4.02 / 583.85 2 4
Average= 4.00
(KJ/cycle)

Cycle 144 GMT 7/ 7/2022 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 33 14.89 417 205 0.20 / 576.07 2 2
2 7 2010.24 36 14.68 2893 1529 1.73 / 577.60 2 2
3 13 1496.92 21 14.70 2287 706 2.44 / 578.31 2 2
4 13 858.64 21 14.75 1487 461 2.90 / 578.77 2 3
5 13 339.52 21 14.85 809 252 3.15 / 579.02 2 3
6 13 91.08 21 14.92 418 131 3.28 / 579.15 2 2
7 8 0.08 165 14.91 274 674 3.96 / 579.83 2 4
Average= 4.00
(KJ/cycle)

Cycle 143 GMT 27/ 6/2022 11:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 33 14.89 411 202 0.20 / 572.03 2 2
2 7 2008.20 37 14.68 2883 1566 1.77 / 573.59 2 2
3 13 1515.32 21 14.69 2320 716 2.48 / 574.31 2 2
4 13 997.60 21 14.73 1678 519 3.00 / 574.83 2 3
5 13 299.12 21 14.87 737 230 3.23 / 575.06 2 3
6 13 79.68 21 14.93 399 125 3.36 / 575.18 2 2
7 8 0.04 165 14.92 278 684 4.04 / 575.87 2 4
Average= 4.00
(KJ/cycle)

Cycle 142 GMT 17/ 6/2022 13:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 33 14.89 415 204 0.20 / 568.03 2 2
2 7 2009.12 36 14.68 2913 1539 1.74 / 569.57 2 2
3 13 1523.32 21 14.69 2337 721 2.46 / 570.29 2 3
4 13 850.00 21 14.75 1495 463 2.93 / 570.76 2 3
5 13 335.96 21 14.85 802 250 3.18 / 571.01 2 3
6 13 89.04 21 14.92 412 129 3.31 / 571.13 2 2
7 8 0.32 165 14.91 281 691 4.00 / 571.83 2 5
Average= 4.00
(KJ/cycle)

Cycle 141 GMT 7/ 6/2022 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 33 14.89 411 202 0.20 / 563.99 2 2
2 7 2012.72 36 14.68 2888 1526 1.73 / 565.52 2 2
3 13 1536.48 21 14.69 2339 722 2.45 / 566.24 2 3
4 13 1025.20 21 14.72 1726 534 2.98 / 566.77 2 4
5 13 318.04 21 14.86 771 241 3.22 / 567.01 2 3
6 13 82.12 21 14.93 411 129 3.35 / 567.14 2 2
7 8 0.04 165 14.92 278 684 4.04 / 567.83 2 5
Average= 4.00
(KJ/cycle)

Cycle 140 GMT 28/ 5/2022 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 33 14.89 409 201 0.20 / 559.95 2 2
2 7 2010.24 36 14.69 2891 1529 1.73 / 561.48 2 2
3 13 1540.04 21 14.69 2343 723 2.45 / 562.20 2 2
4 13 1035.16 21 14.72 1712 529 2.98 / 562.73 2 3
5 13 338.36 21 14.86 794 248 3.23 / 562.98 2 3
6 13 96.32 21 14.93 422 132 3.36 / 563.11 2 2
7 8 0.04 165 14.92 277 682 4.04 / 563.79 2 3
Average= 4.00
(KJ/cycle)

Cycle 139 GMT 18/ 5/2022 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 33 14.90 416 205 0.20 / 555.94 2 2
2 7 2006.68 36 14.68 2896 1530 1.74 / 557.47 2 3
3 13 1531.44 21 14.68 2350 724 2.46 / 558.19 2 3
4 13 869.12 21 14.75 1515 469 2.93 / 558.66 2 2
5 13 353.12 21 14.85 832 259 3.19 / 558.92 2 3
6 13 81.00 21 14.92 412 129 3.32 / 559.05 2 2
7 8 0.12 165 14.91 283 696 4.01 / 559.75 2 4
Average= 4.00
(KJ/cycle)

Cycle 138 GMT 8/ 5/2022 22:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 33 14.89 410 201 0.20 / 551.97 2 2
2 7 2014.44 36 14.69 2892 1529 1.73 / 553.50 2 2
3 13 1535.00 21 14.69 2328 718 2.45 / 554.22 2 3
4 13 854.80 21 14.76 1494 463 2.91 / 554.68 2 3
5 13 334.04 21 14.86 792 247 3.16 / 554.93 2 2
6 13 84.56 21 14.94 406 127 3.29 / 555.06 2 2
7 8 0.16 165 14.92 274 675 3.96 / 555.73 2 7
Average= 4.00
(KJ/cycle)

Cycle 137 GMT 29/ 4/2022 1: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 33 14.90 415 204 0.20 / 548.02 2 2
2 7 2006.52 36 14.69 2889 1528 1.73 / 549.55 2 3
3 13 1518.60 21 14.70 2316 715 2.45 / 550.27 2 3
4 13 853.92 21 14.76 1483 460 2.91 / 550.72 2 5
5 13 324.80 21 14.86 776 242 3.15 / 550.97 2 3
6 13 76.80 21 14.94 393 123 3.27 / 551.09 2 2
7 8 0.04 165 14.92 277 682 3.95 / 551.77 2 4
Average= 4.00
(KJ/cycle)

Cycle 136 GMT 19/ 4/2022 3:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 33 14.91 406 200 0.20 / 543.99 2 2
2 7 2010.08 36 14.68 2886 1525 1.72 / 545.51 2 2
3 13 1658.68 21 14.68 2491 768 2.49 / 546.28 2 3
4 13 952.32 21 14.74 1619 501 2.99 / 546.78 2 4
5 13 288.68 21 14.88 745 233 3.23 / 547.02 2 3
6 13 81.04 21 14.94 397 125 3.35 / 547.14 2 2
7 8 0.12 165 14.93 275 677 4.03 / 547.82 2 4
Average= 4.00
(KJ/cycle)

Cycle 135 GMT 9/ 4/2022 5:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 33 14.89 414 203 0.20 / 539.99 2 2
2 7 2003.04 36 14.69 2882 1524 1.73 / 541.52 2 2
3 13 1522.72 21 14.69 2350 725 2.45 / 542.24 2 2
4 13 991.52 21 14.74 1667 516 2.97 / 542.76 2 4
5 13 297.56 21 14.87 759 237 3.21 / 542.99 2 2
6 13 76.92 21 14.94 399 125 3.33 / 543.12 2 2
7 8 0.16 165 14.93 272 670 4.00 / 543.79 2 4
Average= 4.00
(KJ/cycle)

Cycle 134 GMT 30/ 3/2022 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 33 14.91 416 205 0.20 / 535.96 2 2
2 7 2015.72 37 14.68 2902 1576 1.78 / 537.54 2 3
3 13 1518.40 21 14.69 2332 719 2.50 / 538.26 2 2
4 13 845.72 21 14.77 1470 456 2.96 / 538.71 2 4
5 13 337.00 21 14.86 799 249 3.21 / 538.96 2 3
6 13 82.72 21 14.93 413 129 3.34 / 539.09 2 2
7 8 0.08 165 14.92 283 697 4.03 / 539.79 2 4
Average= 4.00
(KJ/cycle)

Cycle 133 GMT 20/ 3/2022 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 33 14.91 408 201 0.20 / 531.90 2 2
2 7 2010.84 37 14.69 2902 1577 1.78 / 533.47 2 3
3 13 1515.16 21 14.70 2324 717 2.50 / 534.19 2 3
4 13 1012.08 21 14.73 1691 523 3.02 / 534.71 2 2
5 13 297.64 21 14.88 753 235 3.25 / 534.95 2 3
6 13 85.92 21 14.94 408 128 3.38 / 535.08 2 2
7 8 0.24 165 14.93 276 680 4.06 / 535.76 2 5
Average= 4.00
(KJ/cycle)

Cycle 132 GMT 10/ 3/2022 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 33 14.91 403 198 0.20 / 527.87 2 2
2 7 2005.76 36 14.69 2879 1523 1.72 / 529.39 2 3
3 13 1677.04 21 14.68 2528 779 2.50 / 530.17 2 3
4 13 972.36 21 14.74 1641 508 3.01 / 530.68 2 4
5 13 292.32 21 14.88 725 227 3.23 / 530.90 2 2
6 13 81.84 21 14.94 397 125 3.36 / 531.03 2 2
7 8 0.00 165 14.93 271 668 4.03 / 531.70 2 4
Average= 4.00
(KJ/cycle)

Cycle 131 GMT 28/ 2/2022 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 33 14.91 411 202 0.20 / 523.76 2 2
2 7 2011.12 37 14.69 2909 1581 1.78 / 525.34 2 2
3 13 1530.48 21 14.70 2333 720 2.50 / 526.06 2 2
4 13 853.96 21 14.77 1480 459 2.96 / 526.52 2 4
5 13 336.36 21 14.87 795 248 3.21 / 526.77 2 3
6 13 88.76 21 14.94 406 127 3.34 / 526.90 2 2
7 8 0.20 165 14.93 272 670 4.01 / 527.57 2 4
8 14 0.20 25 14.91 270 101 4.11 / 527.67 2 8
Average= 4.00
(KJ/cycle)

Cycle 130 GMT 18/ 2/2022 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 33 14.91 409 201 0.20 / 519.73 2 2
2 7 2007.92 37 14.69 2895 1574 1.77 / 521.30 2 3
3 13 1517.80 21 14.70 2326 718 2.49 / 522.02 2 3
4 13 859.60 21 14.77 1491 462 2.96 / 522.49 2 3
5 13 338.68 21 14.87 789 246 3.20 / 522.73 2 3
6 13 84.92 21 14.94 416 131 3.33 / 522.86 2 2
7 8 0.12 165 14.93 283 697 4.03 / 523.56 2 3
Average= 4.00
(KJ/cycle)

Cycle 129 GMT 8/ 2/2022 18:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 33 14.92 412 203 0.20 / 515.67 2 2
2 7 2005.84 37 14.69 2900 1576 1.78 / 517.24 2 2
3 13 1676.96 21 14.68 2507 773 2.55 / 518.02 2 3
4 13 961.48 21 14.75 1626 504 3.06 / 518.52 2 4
5 13 279.40 21 14.90 708 222 3.28 / 518.74 2 3
6 13 76.24 21 14.95 390 122 3.40 / 518.86 2 2
7 8 0.04 165 14.94 270 666 4.07 / 519.53 2 4
Average= 4.00
(KJ/cycle)

Cycle 128 GMT 29/ 1/2022 21: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 33 14.91 411 202 0.20 / 511.65 2 2
2 7 2006.32 36 14.69 2878 1522 1.72 / 513.17 2 2
3 13 1674.00 21 14.68 2493 769 2.49 / 513.94 2 3
4 13 962.44 21 14.75 1635 506 3.00 / 514.45 2 2
5 13 286.84 21 14.90 725 227 3.23 / 514.67 2 3
6 13 76.04 21 14.96 397 125 3.35 / 514.80 2 2
7 8 0.16 165 14.94 271 668 4.02 / 515.46 2 5
Average= 4.00
(KJ/cycle)

Cycle 127 GMT 19/ 1/2022 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 33 14.92 408 201 0.20 / 507.68 2 2
2 7 2004.76 36 14.69 2884 1525 1.73 / 509.20 2 2
3 13 1519.56 21 14.70 2336 721 2.45 / 509.92 2 3
4 13 857.68 21 14.77 1508 468 2.91 / 510.39 2 3
5 13 333.20 21 14.88 790 247 3.16 / 510.64 2 3
6 13 82.00 21 14.95 411 129 3.29 / 510.77 2 2
7 8 0.20 165 14.93 276 680 3.97 / 511.45 2 9
Average= 4.00
(KJ/cycle)

Cycle 126 GMT 10/ 1/2022 1:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 33 14.92 414 204 0.20 / 503.63 2 2
2 7 2013.72 36 14.70 2895 1532 1.74 / 505.16 2 2
3 13 1691.56 21 14.68 2529 780 2.52 / 505.94 2 3
4 13 966.60 21 14.75 1651 511 3.03 / 506.45 2 3
5 13 287.16 21 14.90 717 224 3.25 / 506.68 2 2
6 13 73.16 21 14.96 384 121 3.37 / 506.80 2 2
7 8 0.04 165 14.94 275 678 4.05 / 507.48 2 4
Average= 4.00
(KJ/cycle)

Cycle 125 GMT 31/12/2021 4:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 33 14.92 410 202 0.20 / 499.60 2 2
2 7 2004.96 36 14.69 2884 1525 1.73 / 501.12 2 2
3 13 1665.16 21 14.69 2495 770 2.50 / 501.89 2 2
4 13 949.20 21 14.75 1628 504 3.00 / 502.40 2 5
5 13 282.36 21 14.90 740 232 3.23 / 502.63 2 3
6 13 73.88 21 14.96 395 124 3.36 / 502.75 2 2
7 8 0.12 165 14.95 273 673 4.03 / 503.43 2 5
Average= 4.00
(KJ/cycle)

Cycle 124 GMT 21/12/2021 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 33 14.92 409 201 0.20 / 495.55 2 2
2 7 2003.60 36 14.70 2892 1530 1.73 / 497.08 2 2
3 13 1663.68 21 14.69 2498 771 2.50 / 497.85 2 3
4 13 970.40 21 14.75 1640 508 3.01 / 498.36 2 4
5 13 287.04 21 14.89 742 232 3.24 / 498.59 2 2
6 13 74.68 21 14.95 401 126 3.37 / 498.72 2 2
7 8 0.04 165 14.94 276 680 4.05 / 499.40 2 4
Average= 4.00
(KJ/cycle)

Cycle 123 GMT 11/12/2021 9: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 33 14.92 410 202 0.20 / 491.60 2 2
2 7 2003.04 36 14.69 2887 1527 1.73 / 493.12 2 3
3 13 1505.24 21 14.71 2316 715 2.44 / 493.84 2 2
4 13 854.04 21 14.77 1487 461 2.91 / 494.30 2 3
5 13 333.52 21 14.88 789 247 3.15 / 494.55 2 2
6 13 80.04 21 14.95 401 126 3.28 / 494.67 2 2
7 8 0.16 165 14.94 274 675 3.95 / 495.35 2 3
Average= 3.99
(KJ/cycle)

Cycle 122 GMT 1/12/2021 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 33 14.92 409 201 0.20 / 487.60 2 2
2 7 2003.64 36 14.70 2899 1534 1.74 / 489.13 2 3
3 13 1511.04 21 14.71 2335 721 2.46 / 489.86 2 2
4 13 970.04 21 14.75 1650 511 2.97 / 490.37 2 3
5 13 287.80 21 14.90 725 227 3.19 / 490.59 2 3
6 13 70.00 21 14.96 386 121 3.32 / 490.72 2 2
7 8 0.08 165 14.95 275 678 3.99 / 491.39 2 4
Average= 4.00
(KJ/cycle)

Cycle 121 GMT 21/11/2021 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 33 14.92 412 203 0.20 / 483.57 2 2
2 7 2016.24 37 14.69 2902 1577 1.78 / 485.15 2 2
3 13 1531.92 21 14.70 2352 726 2.51 / 485.88 2 2
4 13 861.36 21 14.77 1502 466 2.97 / 486.34 2 3
5 13 336.72 21 14.89 783 245 3.22 / 486.59 2 3
6 13 82.96 21 14.95 408 128 3.35 / 486.72 2 2
7 8 0.16 165 14.94 277 683 4.03 / 487.40 2 4
Average= 4.00
(KJ/cycle)

Cycle 120 GMT 11/11/2021 16: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 33 14.92 418 206 0.21 / 479.59 2 2
2 7 2004.88 36 14.70 2883 1526 1.73 / 481.11 2 2
3 13 1505.44 21 14.71 2313 715 2.45 / 481.83 2 3
4 13 982.76 21 14.75 1657 513 2.96 / 482.34 2 3
5 13 287.44 21 14.90 730 228 3.19 / 482.57 2 3
6 13 75.52 21 14.96 399 125 3.31 / 482.69 2 2
7 8 0.00 165 14.95 275 678 3.99 / 483.37 2 4
Average= 3.99
(KJ/cycle)

Cycle 119 GMT 1/11/2021 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 33 14.92 412 203 0.20 / 475.52 2 2
2 7 2009.32 36 14.70 2888 1528 1.73 / 477.05 2 3
3 13 1678.52 21 14.68 2532 781 2.51 / 477.83 2 3
4 13 963.96 21 14.76 1619 502 3.01 / 478.33 2 3
5 13 294.48 21 14.90 738 231 3.24 / 478.56 2 3
6 13 77.12 21 14.96 399 125 3.37 / 478.68 2 2
7 8 0.08 165 14.95 282 696 4.07 / 479.38 2 5
Average= 3.99
(KJ/cycle)

Cycle 118 GMT 22/10/2021 20:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 33 14.92 412 203 0.20 / 471.47 2 2
2 7 2009.84 36 14.70 2906 1538 1.74 / 473.01 2 2
3 13 1531.72 21 14.70 2353 726 2.47 / 473.73 2 2
4 13 997.04 21 14.75 1689 523 2.99 / 474.26 2 3
5 13 305.56 21 14.89 761 238 3.23 / 474.50 2 3
6 13 82.24 21 14.96 409 128 3.36 / 474.62 2 2
7 8 0.04 165 14.95 280 691 4.05 / 475.31 2 3
Average= 3.99
(KJ/cycle)

Cycle 117 GMT 12/10/2021 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 33 14.93 412 203 0.20 / 467.48 2 2
2 7 2006.00 36 14.70 2892 1530 1.73 / 469.01 2 3
3 13 1516.24 21 14.70 2338 722 2.46 / 469.73 2 3
4 13 856.36 21 14.78 1512 469 2.92 / 470.20 2 4
5 13 351.80 21 14.89 809 253 3.18 / 470.46 2 3
6 13 94.96 21 14.96 425 134 3.31 / 470.59 2 2
7 8 0.08 165 14.95 275 678 3.99 / 471.27 2 5
Average= 3.99
(KJ/cycle)

Cycle 116 GMT 3/10/2021 1:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 33 14.92 415 204 0.20 / 463.49 2 2
2 7 2009.72 36 14.70 2882 1525 1.73 / 465.02 2 2
3 13 1520.48 21 14.71 2334 721 2.45 / 465.74 2 2
4 13 860.84 21 14.78 1500 466 2.92 / 466.20 2 4
5 13 341.60 21 14.89 804 251 3.17 / 466.45 2 3
6 13 97.12 21 14.96 430 135 3.30 / 466.59 2 2
7 8 0.20 165 14.95 279 688 3.99 / 467.28 2 4
Average= 3.99
(KJ/cycle)

Cycle 115 GMT 23/ 9/2021 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 33 14.93 415 204 0.20 / 459.48 2 2
2 7 2007.04 36 14.70 2875 1521 1.73 / 461.00 3 2
3 13 1538.96 21 14.70 2358 728 2.45 / 461.73 2 3
4 13 860.88 21 14.78 1511 469 2.92 / 462.20 2 4
5 13 348.32 21 14.88 822 257 3.18 / 462.46 2 3
6 13 92.44 21 14.96 423 133 3.31 / 462.59 2 2
7 8 0.08 165 14.95 283 698 4.01 / 463.29 2 3
Average= 3.99
(KJ/cycle)

Cycle 114 GMT 13/ 9/2021 6: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 33 14.93 419 206 0.21 / 455.48 2 2
2 7 2005.92 36 14.70 2882 1525 1.73 / 457.00 2 2
3 13 1509.60 21 14.72 2316 716 2.45 / 457.72 2 2
4 13 864.84 21 14.78 1512 469 2.92 / 458.19 2 3
5 13 340.92 21 14.89 819 256 3.17 / 458.44 2 3
6 13 92.36 21 14.96 426 134 3.31 / 458.58 2 2
7 8 0.20 165 14.95 283 698 4.00 / 459.28 2 4
Average= 3.99
(KJ/cycle)

Cycle 113 GMT 3/ 9/2021 8:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 33 14.93 423 208 0.21 / 451.44 2 2
2 7 2005.36 36 14.70 2875 1521 1.73 / 452.97 2 3
3 13 1674.76 21 14.69 2522 778 2.51 / 453.74 2 3
4 13 834.12 21 14.79 1473 457 2.97 / 454.20 2 4
5 13 327.40 21 14.90 778 243 3.21 / 454.44 2 3
6 13 89.68 21 14.97 424 133 3.34 / 454.58 2 2
7 8 0.16 165 14.96 281 694 4.04 / 455.27 2 4
Average= 3.99
(KJ/cycle)

Cycle 112 GMT 24/ 8/2021 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 33 14.93 417 205 0.21 / 447.40 2 2
2 7 2005.16 37 14.70 2883 1568 1.77 / 448.97 2 2
3 13 1503.76 21 14.72 2313 715 2.49 / 449.69 2 3
4 13 862.80 21 14.78 1499 465 2.95 / 450.15 2 4
5 13 345.28 21 14.90 798 250 3.20 / 450.40 2 3
6 13 89.44 21 14.97 427 134 3.34 / 450.53 2 2
7 8 0.08 165 14.96 284 701 4.04 / 451.24 2 5
Average= 3.99
(KJ/cycle)

Cycle 111 GMT 14/ 8/2021 12:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 33 14.93 424 209 0.21 / 443.38 2 2
2 7 2011.12 36 14.70 2893 1531 1.74 / 444.91 2 3
3 13 1527.00 21 14.71 2336 722 2.46 / 445.64 2 2
4 13 872.72 21 14.78 1517 471 2.93 / 446.11 2 3
5 13 348.44 21 14.89 816 255 3.19 / 446.36 2 3
6 13 90.60 21 14.97 420 132 3.32 / 446.49 2 2
7 8 0.04 165 14.95 285 703 4.02 / 447.20 2 4
Average= 3.99
(KJ/cycle)

Cycle 110 GMT 4/ 8/2021 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 33 14.93 417 205 0.21 / 439.35 2 2
2 7 2011.28 36 14.70 2894 1532 1.74 / 440.88 3 3
3 13 1509.76 21 14.72 2324 718 2.46 / 441.60 2 2
4 13 985.68 21 14.76 1679 520 2.98 / 442.12 2 3
5 13 301.12 21 14.91 759 238 3.21 / 442.36 2 3
6 13 88.84 21 14.97 421 132 3.35 / 442.49 2 2
7 8 0.08 165 14.96 277 684 4.03 / 443.17 2 3
Average= 3.99
(KJ/cycle)

Cycle 109 GMT 25/ 7/2021 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 33 14.94 418 206 0.21 / 435.26 2 2
2 7 2014.08 36 14.70 2895 1532 1.74 / 436.79 2 3
3 13 1686.64 21 14.69 2551 787 2.53 / 437.57 2 3
4 13 983.32 21 14.76 1676 519 3.04 / 438.09 2 3
5 13 292.36 21 14.92 734 230 3.27 / 438.32 2 3
6 13 73.64 21 14.98 398 125 3.40 / 438.45 2 2
7 8 0.04 165 14.96 282 696 4.10 / 439.15 2 7
Average= 3.99
(KJ/cycle)

Cycle 108 GMT 15/ 7/2021 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 33 14.93 415 204 0.20 / 431.19 2 2
2 7 2011.48 36 14.70 2912 1541 1.75 / 432.73 2 2
3 13 1520.40 21 14.71 2343 724 2.47 / 433.46 2 3
4 13 992.16 21 14.76 1688 523 2.99 / 433.98 2 4
5 13 293.96 21 14.91 754 236 3.23 / 434.21 2 3
6 13 73.32 21 14.98 410 129 3.36 / 434.34 2 2
7 8 0.16 165 14.96 286 706 4.06 / 435.05 2 3
Average= 3.99
(KJ/cycle)

Cycle 107 GMT 5/ 7/2021 21:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 33 14.93 407 201 0.20 / 427.23 2 2
2 7 2005.48 36 14.71 2881 1526 1.73 / 428.76 2 2
3 13 1508.84 21 14.72 2311 714 2.44 / 429.47 2 2
4 13 841.00 21 14.80 1474 458 2.90 / 429.93 2 3
5 13 318.08 21 14.91 773 242 3.14 / 430.17 2 3
6 13 79.16 21 14.98 402 126 3.27 / 430.30 2 2
7 8 0.04 165 14.96 278 686 3.95 / 430.99 2 4
Average= 3.99
(KJ/cycle)

Cycle 106 GMT 26/ 6/2021 0:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 33 14.95 401 198 0.20 / 423.19 2 2
2 7 2012.40 36 14.70 2899 1534 1.73 / 424.73 2 2
3 13 1691.36 21 14.69 2538 783 2.51 / 425.51 2 3
4 13 832.72 21 14.80 1464 455 2.97 / 425.97 2 2
5 13 329.04 21 14.90 785 246 3.22 / 426.21 2 3
6 13 91.36 21 14.97 423 133 3.35 / 426.34 2 2
7 8 0.08 165 14.96 279 689 4.04 / 427.03 2 4
Average= 3.99
(KJ/cycle)

Cycle 105 GMT 16/ 6/2021 2:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 33 14.94 416 205 0.21 / 419.18 2 2
2 7 2003.88 37 14.71 2880 1567 1.77 / 420.75 2 3
3 13 1514.12 21 14.73 2321 718 2.49 / 421.46 2 3
4 13 980.64 21 14.77 1654 513 3.00 / 421.98 2 2
5 13 296.60 21 14.92 733 230 3.23 / 422.21 2 3
6 13 86.32 21 14.98 408 128 3.36 / 422.34 2 2
7 8 0.12 165 14.98 267 660 4.02 / 423.00 2 4
Average= 3.99
(KJ/cycle)

Cycle 104 GMT 6/ 6/2021 4:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 33 14.94 413 204 0.20 / 415.17 2 2
2 7 2006.92 36 14.72 2895 1534 1.74 / 416.71 2 3
3 13 1525.48 21 14.72 2355 728 2.47 / 417.43 2 2
4 13 858.00 21 14.80 1503 467 2.93 / 417.90 2 3
5 13 340.60 21 14.90 808 253 3.19 / 418.15 2 3
6 13 100.00 21 14.97 431 135 3.32 / 418.29 2 2
7 8 0.12 165 14.97 277 684 4.01 / 418.97 2 4
Average= 3.99
(KJ/cycle)

Cycle 103 GMT 27/ 5/2021 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 33 14.95 405 200 0.20 / 411.14 2 2
2 7 2008.32 36 14.71 2879 1525 1.72 / 412.67 2 2
3 13 1515.68 21 14.73 2310 715 2.44 / 413.38 2 2
4 13 997.44 21 14.77 1678 520 2.96 / 413.90 2 5
5 13 299.12 21 14.92 765 240 3.20 / 414.14 2 3
6 13 82.92 21 14.98 415 131 3.33 / 414.27 2 2
7 8 0.08 165 14.97 281 694 4.02 / 414.97 2 4
Average= 3.99
(KJ/cycle)

Cycle 102 GMT 17/ 5/2021 9: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 33 14.94 414 204 0.20 / 407.06 2 2
2 7 2005.20 37 14.71 2885 1570 1.77 / 408.63 3 2
3 13 1662.36 21 14.70 2518 777 2.55 / 409.40 2 2
4 13 953.56 21 14.78 1628 505 3.06 / 409.91 2 2
5 13 268.08 21 14.94 697 219 3.28 / 410.13 2 2
6 13 80.56 21 14.99 412 130 3.41 / 410.26 2 2
7 8 0.08 165 14.98 278 687 4.09 / 410.94 2 5
Average= 3.99
(KJ/cycle)

Cycle 101 GMT 7/ 5/2021 11:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 33 14.94 412 203 0.20 / 403.07 2 2
2 7 2003.88 36 14.72 2880 1526 1.73 / 404.59 2 2
3 13 1525.00 21 14.73 2349 727 2.46 / 405.32 2 2
4 13 852.00 21 14.80 1498 466 2.92 / 405.79 2 3
5 13 339.08 21 14.91 807 253 3.17 / 406.04 2 3
6 13 89.68 21 14.98 419 132 3.31 / 406.17 2 2
7 8 0.04 165 14.97 276 682 3.99 / 406.85 2 3
Average= 3.99
(KJ/cycle)

Cycle 100 GMT 27/ 4/2021 13:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 33 14.95 414 204 0.20 / 399.07 2 2
2 7 2005.80 36 14.72 2878 1525 1.73 / 400.59 2 3
3 13 1527.68 21 14.72 2357 729 2.46 / 401.32 2 3
4 13 849.92 21 14.80 1507 468 2.93 / 401.79 2 4
5 13 332.04 21 14.91 782 245 3.17 / 402.03 2 3
6 13 88.48 21 14.98 418 131 3.30 / 402.17 2 2
7 8 0.16 165 14.97 283 699 4.00 / 402.86 2 4
Average= 3.99
(KJ/cycle)

Cycle 99 GMT 17/ 4/2021 16: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 33 14.96 413 204 0.20 / 395.05 2 2
2 7 2009.36 36 14.72 2877 1525 1.73 / 396.58 2 2
3 13 1527.52 21 14.73 2323 719 2.45 / 397.30 2 2
4 13 997.28 21 14.77 1681 521 2.97 / 397.82 2 4
5 13 302.32 21 14.93 752 236 3.20 / 398.05 2 3
6 13 90.48 21 14.99 417 131 3.34 / 398.19 2 2
7 8 0.12 165 14.98 274 677 4.01 / 398.86 2 4
Average= 3.99
(KJ/cycle)

Cycle 98 GMT 7/ 4/2021 18:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 33 14.95 416 205 0.21 / 391.01 2 2
2 7 2004.76 36 14.72 2899 1536 1.74 / 392.54 2 2
3 13 1675.40 21 14.71 2529 781 2.52 / 393.32 2 2
4 13 940.24 21 14.79 1608 499 3.02 / 393.82 2 3
5 13 268.80 21 14.95 689 216 3.24 / 394.04 2 2
6 13 80.56 21 15.00 404 127 3.37 / 394.17 2 2
7 8 0.12 165 14.99 276 683 4.05 / 394.85 2 4
Average= 3.99
(KJ/cycle)

Cycle 97 GMT 28/ 3/2021 20:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 33 14.95 420 207 0.21 / 387.03 2 2
2 7 2012.56 36 14.72 2886 1529 1.74 / 388.56 2 2
3 13 1523.20 21 14.74 2316 717 2.45 / 389.28 2 2
4 13 826.60 21 14.81 1466 456 2.91 / 389.74 2 3
5 13 320.80 21 14.92 771 242 3.15 / 389.98 2 3
6 13 84.16 21 14.99 412 130 3.28 / 390.11 2 2
7 8 0.04 165 14.98 281 695 3.98 / 390.80 2 4
Average= 3.99
(KJ/cycle)

Cycle 96 GMT 18/ 3/2021 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 33 14.97 414 205 0.20 / 383.05 2 2
2 7 2011.00 36 14.72 2890 1531 1.74 / 384.58 2 2
3 13 1530.24 21 14.73 2346 726 2.46 / 385.31 2 3
4 13 849.48 21 14.81 1485 462 2.92 / 385.77 2 4
5 13 326.64 21 14.92 789 247 3.17 / 386.02 2 3
6 13 83.80 21 14.99 415 131 3.30 / 386.15 2 2
7 8 0.12 165 14.98 275 680 3.98 / 386.83 2 4
Average= 3.99
(KJ/cycle)

Cycle 95 GMT 9/ 3/2021 1:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 33 14.96 417 206 0.21 / 379.06 2 2
2 7 2012.24 36 14.72 2884 1528 1.73 / 380.59 2 2
3 13 1498.48 21 14.74 2299 712 2.45 / 381.30 2 2
4 13 971.84 21 14.79 1646 511 2.96 / 381.82 2 3
5 13 280.52 21 14.95 712 224 3.18 / 382.04 2 3
6 13 84.28 21 15.00 400 126 3.31 / 382.17 2 2
7 8 0.20 165 14.99 275 680 3.99 / 382.85 2 7
Average= 3.99
(KJ/cycle)

Cycle 94 GMT 27/ 2/2021 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 33 14.96 414 204 0.20 / 375.12 2 2
2 7 2004.04 36 14.73 2879 1527 1.73 / 376.65 2 3
3 13 1480.36 21 14.75 2279 706 2.44 / 377.36 2 2
4 13 819.04 21 14.82 1467 457 2.89 / 377.81 2 3
5 13 309.68 21 14.94 744 233 3.13 / 378.05 2 3
6 13 84.76 21 15.00 406 128 3.25 / 378.17 2 2
7 8 0.08 165 14.99 277 685 3.94 / 378.86 2 4
Average= 3.99
(KJ/cycle)

Cycle 93 GMT 17/ 2/2021 5:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 33 14.96 424 209 0.21 / 371.04 2 2
2 7 2017.04 36 14.73 2901 1538 1.75 / 372.58 2 2
3 13 1533.64 21 14.73 2352 728 2.48 / 373.31 2 2
4 13 1009.32 21 14.78 1698 527 3.00 / 373.83 2 3
5 13 316.52 21 14.93 777 244 3.25 / 374.08 2 3
6 13 93.08 21 15.00 429 135 3.38 / 374.21 2 2
7 8 0.08 165 14.99 285 705 4.09 / 374.92 2 5
Average= 3.99
(KJ/cycle)

Cycle 92 GMT 7/ 2/2021 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 33 14.97 429 212 0.21 / 367.00 2 2
2 7 2002.56 36 14.73 2891 1533 1.74 / 368.54 3 3
3 13 1506.68 21 14.74 2329 721 2.47 / 369.26 2 3
4 13 857.08 21 14.81 1511 470 2.94 / 369.73 2 4
5 13 348.52 21 14.92 833 261 3.20 / 369.99 2 3
6 13 101.52 21 14.99 450 142 3.34 / 370.13 2 2
7 8 0.00 165 14.99 284 702 4.04 / 370.83 2 4
Average= 3.99
(KJ/cycle)

Cycle 91 GMT 28/ 1/2021 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 33 14.97 419 207 0.21 / 362.92 2 2
2 7 2006.16 37 14.73 2882 1571 1.78 / 364.50 2 2
3 13 1507.32 21 14.74 2314 716 2.49 / 365.21 2 2
4 13 983.84 21 14.79 1649 512 3.01 / 365.72 2 3
5 13 288.60 21 14.94 732 230 3.24 / 365.95 2 2
6 13 95.36 21 15.00 429 135 3.37 / 366.09 2 2
7 8 0.12 165 15.00 284 703 4.07 / 366.79 2 4
Average= 3.99
(KJ/cycle)

Cycle 90 GMT 18/ 1/2021 12:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 33 14.97 421 208 0.21 / 358.87 2 2
2 7 2004.16 37 14.73 2884 1572 1.78 / 360.44 2 2
3 13 1503.12 21 14.75 2318 718 2.50 / 361.16 2 2
4 13 851.64 21 14.82 1511 470 2.97 / 361.63 2 4
5 13 341.40 21 14.93 812 255 3.22 / 361.88 2 2
6 13 98.36 21 15.00 430 135 3.36 / 362.02 2 2
7 8 0.04 165 14.99 283 700 4.06 / 362.72 2 4
Average= 3.99
(KJ/cycle)

Cycle 89 GMT 8/ 1/2021 14:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 33 14.96 425 210 0.21 / 354.84 2 2
2 7 2003.20 36 14.73 2884 1529 1.74 / 356.37 2 2
3 13 1502.56 21 14.75 2324 720 2.46 / 357.09 2 2
4 13 973.12 21 14.80 1654 514 2.97 / 357.61 2 4
5 13 287.40 21 14.96 720 226 3.20 / 357.83 2 3
6 13 84.24 21 15.01 422 133 3.33 / 357.97 2 2
7 8 0.12 165 15.00 280 693 4.03 / 358.66 2 4
Average= 3.99
(KJ/cycle)

Cycle 88 GMT 29/12/2020 17: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 33 14.97 420 207 0.21 / 350.83 2 2
2 7 2007.04 36 14.73 2890 1533 1.74 / 352.37 2 2
3 13 1511.16 21 14.75 2333 723 2.46 / 353.09 2 2
4 13 842.44 21 14.82 1484 462 2.92 / 353.55 2 3
5 13 324.60 21 14.94 772 242 3.17 / 353.79 2 3
6 13 90.56 21 15.00 429 135 3.30 / 353.93 2 2
7 8 0.16 165 14.99 286 707 4.01 / 354.63 2 3
Average= 3.98
(KJ/cycle)

Cycle 87 GMT 19/12/2020 19:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 33 14.98 418 207 0.21 / 346.78 2 2
2 7 2008.52 36 14.73 2906 1541 1.75 / 348.33 3 3
3 13 1502.68 21 14.74 2332 722 2.47 / 349.05 2 3
4 13 984.40 21 14.79 1677 521 2.99 / 349.57 2 3
5 13 286.16 21 14.95 734 230 3.22 / 349.80 2 2
6 13 86.72 21 15.01 424 134 3.35 / 349.93 2 2
7 8 0.20 165 15.00 280 693 4.05 / 350.63 2 3
Average= 3.98
(KJ/cycle)

Cycle 86 GMT 9/12/2020 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 33 14.98 423 209 0.21 / 342.74 2 2
2 7 2008.08 36 14.73 2892 1534 1.74 / 344.27 2 2
3 13 1524.48 21 14.74 2344 726 2.47 / 345.00 2 2
4 13 1000.20 21 14.79 1692 526 2.99 / 345.52 2 4
5 13 284.76 21 14.95 741 233 3.23 / 345.76 2 2
6 13 86.28 21 15.01 420 132 3.36 / 345.89 2 2
7 8 0.08 165 15.01 278 689 4.05 / 346.58 2 3
Average= 3.98
(KJ/cycle)

Cycle 85 GMT 29/11/2020 23:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 33 14.98 425 210 0.21 / 338.64 2 2
2 7 2004.28 36 14.75 2891 1535 1.75 / 340.18 2 2
3 13 1672.92 21 14.73 2524 781 2.53 / 340.96 2 3
4 13 959.96 21 14.81 1635 509 3.03 / 341.47 2 5
5 13 285.64 21 14.96 737 232 3.27 / 341.70 2 2
6 13 90.36 21 15.02 425 134 3.40 / 341.83 2 2
7 8 0.20 165 15.01 281 696 4.10 / 342.53 2 4
Average= 3.98
(KJ/cycle)

Cycle 84 GMT 20/11/2020 1:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 33 14.97 439 217 0.22 / 334.56 2 2
2 7 2006.88 36 14.74 2891 1534 1.75 / 336.09 2 3
3 13 1530.12 21 14.75 2368 733 2.48 / 336.82 2 3
4 13 1017.28 21 14.79 1720 534 3.02 / 337.36 2 3
5 13 311.40 21 14.95 779 245 3.26 / 337.60 2 3
6 13 90.04 21 15.02 421 133 3.40 / 337.74 2 2
7 8 0.04 165 15.01 282 698 4.09 / 338.43 2 4
Average= 3.98
(KJ/cycle)

Cycle 83 GMT 10/11/2020 4: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 32 14.99 419 201 0.20 / 330.49 2 2
2 7 2010.28 36 14.74 2906 1542 1.74 / 332.03 2 3
3 13 1529.76 21 14.75 2358 730 2.47 / 332.76 2 2
4 13 849.56 21 14.84 1507 470 2.94 / 333.23 2 3
5 13 327.20 21 14.95 794 249 3.19 / 333.48 2 2
6 13 86.64 21 15.02 432 136 3.33 / 333.61 2 2
7 8 0.08 165 15.01 293 726 4.05 / 334.34 2 4
Average= 3.98
(KJ/cycle)

Cycle 82 GMT 31/10/2020 6:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 14.99 418 201 0.20 / 326.46 2 2
2 7 2002.92 36 14.74 2895 1536 1.74 / 327.99 2 2
3 13 1513.80 21 14.76 2320 719 2.46 / 328.71 2 2
4 13 983.60 21 14.81 1668 519 2.97 / 329.23 2 4
5 13 288.64 21 14.97 730 229 3.20 / 329.46 2 3
6 13 83.72 21 15.03 412 130 3.33 / 329.59 2 2
7 8 0.12 165 15.02 280 694 4.03 / 330.29 2 5
Average= 3.98
(KJ/cycle)

Cycle 81 GMT 21/10/2020 8:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 32 14.99 417 200 0.20 / 322.46 2 2
2 7 2010.08 36 14.74 2898 1538 1.74 / 324.00 2 3
3 13 1512.96 21 14.75 2343 726 2.46 / 324.73 2 3
4 13 830.60 21 14.85 1480 462 2.93 / 325.19 2 5
5 13 309.48 21 14.96 770 242 3.17 / 325.43 2 2
6 13 88.60 21 15.03 420 133 3.30 / 325.56 2 2
7 8 0.00 165 15.02 281 696 4.00 / 326.26 2 4
Average= 3.98
(KJ/cycle)

Cycle 80 GMT 11/10/2020 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 15.00 416 200 0.20 / 318.42 2 2
2 7 2003.24 36 14.75 2876 1527 1.73 / 319.94 3 2
3 13 1503.52 21 14.76 2327 721 2.45 / 320.67 2 2
4 13 984.68 21 14.81 1680 522 2.97 / 321.19 2 4
5 13 287.88 21 14.98 741 233 3.20 / 321.42 2 3
6 13 83.76 21 15.03 418 132 3.34 / 321.55 2 2
7 8 0.24 165 15.02 286 709 4.04 / 322.26 2 3
Average= 3.98
(KJ/cycle)

Cycle 79 GMT 1/10/2020 13: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 32 15.00 418 201 0.20 / 314.34 2 2
2 7 2004.36 37 14.75 2906 1586 1.79 / 315.92 2 2
3 13 1512.08 21 14.77 2329 722 2.51 / 316.64 2 3
4 13 992.32 21 14.82 1681 523 3.03 / 317.17 2 4
5 13 277.24 21 14.99 714 225 3.26 / 317.39 2 2
6 13 78.32 21 15.04 409 129 3.39 / 317.52 2 2
7 8 0.16 165 15.03 281 697 4.08 / 318.22 2 4
Average= 3.98
(KJ/cycle)

Cycle 78 GMT 21/ 9/2020 15:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 32 15.00 416 200 0.20 / 310.32 2 2
2 7 2003.00 36 14.76 2875 1528 1.73 / 311.85 2 2
3 13 1507.28 21 14.77 2331 723 2.45 / 312.57 2 2
4 13 972.64 21 14.82 1661 517 2.97 / 313.09 2 6
5 13 277.40 21 14.99 727 229 3.20 / 313.31 2 2
6 13 84.96 21 15.05 414 131 3.33 / 313.44 2 2
7 8 0.08 165 15.04 278 690 4.02 / 314.13 2 4
Average= 3.98
(KJ/cycle)

Cycle 77 GMT 11/ 9/2020 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 15.01 425 204 0.20 / 306.30 2 2
2 7 2006.88 36 14.76 2886 1534 1.74 / 307.83 2 2
3 13 1526.68 21 14.77 2345 727 2.46 / 308.56 2 3
4 13 864.92 21 14.86 1500 468 2.93 / 309.03 2 3
5 13 333.44 21 14.97 802 252 3.19 / 309.28 2 2
6 13 80.40 21 15.05 415 131 3.32 / 309.41 2 2
7 8 0.00 165 15.03 285 707 4.02 / 310.12 2 6
Average= 3.98
(KJ/cycle)

Cycle 76 GMT 1/ 9/2020 20: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 32 15.01 418 201 0.20 / 302.21 2 2
2 7 2005.48 37 14.76 2878 1572 1.77 / 303.78 2 2
3 13 1511.88 21 14.78 2330 723 2.50 / 304.50 2 3
4 13 995.64 21 14.82 1693 527 3.02 / 305.03 2 2
5 13 296.88 21 14.99 741 233 3.26 / 305.26 2 3
6 13 83.80 21 15.05 421 133 3.39 / 305.40 2 2
7 8 0.16 165 15.04 281 697 4.09 / 306.09 2 3
Average= 3.98
(KJ/cycle)

Cycle 75 GMT 22/ 8/2020 22:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 32 15.02 420 202 0.20 / 298.16 2 2
2 7 2004.68 36 14.76 2905 1544 1.75 / 299.70 2 2
3 13 1519.92 21 14.77 2344 727 2.47 / 300.43 2 2
4 13 849.64 21 14.86 1515 473 2.95 / 300.90 2 3
5 13 317.44 21 14.98 792 249 3.19 / 301.15 2 3
6 13 82.56 21 15.05 426 135 3.33 / 301.29 2 2
7 8 0.16 165 15.04 291 722 4.05 / 302.01 2 6
Average= 3.97
(KJ/cycle)

Cycle 74 GMT 13/ 8/2020 0:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 32 15.03 423 203 0.20 / 294.14 2 2
2 7 2011.00 36 14.76 2900 1541 1.74 / 295.68 2 3
3 13 1503.80 21 14.78 2328 723 2.47 / 296.41 2 2
4 13 832.76 21 14.87 1490 465 2.93 / 296.87 2 3
5 13 302.56 21 15.00 765 241 3.17 / 297.11 2 3
6 13 70.88 21 15.07 411 130 3.30 / 297.24 2 2
7 8 0.16 165 15.05 288 715 4.02 / 297.96 2 4
Average= 3.97
(KJ/cycle)

Cycle 73 GMT 3/ 8/2020 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 32 15.03 439 211 0.21 / 290.08 2 2
2 7 2004.52 36 14.76 2894 1538 1.75 / 291.62 2 2
3 13 1517.84 21 14.78 2339 726 2.47 / 292.34 2 2
4 13 989.96 21 14.84 1668 520 2.99 / 292.86 2 6
5 13 282.52 21 15.01 733 231 3.23 / 293.10 2 3
6 13 73.16 21 15.07 412 130 3.36 / 293.23 2 2
7 8 0.08 165 15.06 287 713 4.07 / 293.94 2 5
Average= 3.97
(KJ/cycle)

Cycle 72 GMT 24/ 7/2020 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 32 15.03 425 204 0.20 / 286.02 2 2
2 7 2003.80 36 14.76 2900 1541 1.75 / 287.56 2 2
3 13 1503.16 21 14.78 2320 720 2.47 / 288.28 2 2
4 13 983.08 21 14.84 1663 518 2.98 / 288.80 2 2
5 13 273.00 21 15.02 710 224 3.21 / 289.02 2 2
6 13 73.32 21 15.08 406 129 3.34 / 289.15 2 2
7 8 -0.04 165 15.06 289 718 4.05 / 289.87 2 4
Average= 3.97
(KJ/cycle)

Cycle 71 GMT 14/ 7/2020 7:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 32 15.04 430 207 0.21 / 281.89 2 2
2 7 2005.80 36 14.77 2886 1535 1.74 / 283.43 2 3
3 13 1511.92 21 14.79 2317 720 2.46 / 284.14 2 2
4 13 866.56 21 14.87 1529 477 2.94 / 284.62 2 4
5 13 345.36 21 15.00 822 259 3.20 / 284.88 2 3
6 13 87.56 21 15.08 424 134 3.33 / 285.02 2 2
7 13 23.64 21 15.09 328 104 3.44 / 285.12 2 2
8 8 -0.04 165 15.06 280 696 4.13 / 285.82 2 3
Average= 3.97
(KJ/cycle)

Cycle 70 GMT 4/ 7/2020 10:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 32 15.04 427 206 0.21 / 277.84 2 2
2 7 2004.32 37 14.77 2899 1584 1.79 / 279.42 2 2
3 13 1517.52 21 14.78 2343 727 2.52 / 280.15 2 2
4 13 831.76 21 14.89 1477 462 2.98 / 280.61 2 4
5 13 296.04 21 15.02 751 237 3.22 / 280.85 2 3
6 13 73.48 21 15.09 401 127 3.34 / 280.97 2 2
7 8 0.08 165 15.07 285 709 4.05 / 281.68 2 5
Average= 3.97
(KJ/cycle)

Cycle 69 GMT 24/ 6/2020 12:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 32 15.06 415 200 0.20 / 273.77 2 2
2 7 2011.80 36 14.77 2889 1536 1.74 / 275.31 3 2
3 13 1516.72 21 14.79 2324 722 2.46 / 276.03 2 2
4 13 989.60 21 14.84 1679 523 2.98 / 276.56 2 4
5 13 285.40 21 15.02 739 233 3.21 / 276.79 2 3
6 13 74.48 21 15.09 410 130 3.34 / 276.92 2 2
7 8 0.16 165 15.07 287 714 4.06 / 277.63 2 5
Average= 3.97
(KJ/cycle)

Cycle 68 GMT 14/ 6/2020 14:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 32 15.06 423 204 0.20 / 269.62 2 2
2 7 2012.92 37 14.77 2896 1583 1.79 / 271.21 2 3
3 13 1524.72 21 14.79 2332 724 2.51 / 271.93 2 3
4 13 857.32 21 14.89 1501 469 2.98 / 272.40 2 6
5 13 323.32 21 15.02 785 248 3.23 / 272.65 2 3
6 13 86.44 21 15.09 420 133 3.36 / 272.78 2 2
7 13 22.56 21 15.10 322 102 3.46 / 272.88 2 2
8 8 0.00 165 15.08 278 692 4.15 / 273.57 2 3
Average= 3.96
(KJ/cycle)

Cycle 67 GMT 4/ 6/2020 16:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 32 15.07 416 201 0.20 / 265.59 2 2
2 7 2007.76 36 14.77 2913 1549 1.75 / 267.14 2 2
3 13 1522.36 21 14.79 2354 731 2.48 / 267.87 2 3
4 13 837.40 21 14.90 1466 459 2.94 / 268.33 2 3
5 13 299.28 21 15.03 763 241 3.18 / 268.57 2 3
6 13 86.12 21 15.10 424 134 3.31 / 268.70 2 2
7 8 0.20 165 15.09 288 717 4.03 / 269.42 2 4
Average= 3.96
(KJ/cycle)

Cycle 66 GMT 25/ 5/2020 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 32 15.07 421 203 0.20 / 261.60 2 2
2 7 2004.52 36 14.77 2885 1534 1.74 / 263.14 2 3
3 13 1498.48 21 14.80 2312 719 2.46 / 263.86 2 3
4 13 822.16 21 14.91 1457 456 2.91 / 264.31 2 4
5 13 300.16 21 15.04 757 239 3.15 / 264.55 2 2
6 13 80.92 21 15.11 416 132 3.28 / 264.68 2 2
7 8 0.20 165 15.10 283 705 3.99 / 265.39 2 3
Average= 3.96
(KJ/cycle)

Cycle 65 GMT 15/ 5/2020 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 32 15.06 421 203 0.20 / 257.45 2 2
2 7 2004.08 36 14.78 2897 1541 1.74 / 258.99 2 3
3 13 1520.52 21 14.80 2348 730 2.47 / 259.72 2 3
4 13 984.24 21 14.87 1675 523 3.00 / 260.25 2 5
5 13 281.52 21 15.05 719 227 3.22 / 260.47 2 2
6 13 84.92 21 15.11 417 132 3.36 / 260.61 2 2
7 13 23.12 21 15.12 318 101 3.46 / 260.71 2 2
8 8 0.08 165 15.10 278 693 4.15 / 261.40 2 4
Average= 3.96
(KJ/cycle)

Cycle 64 GMT 5/ 5/2020 23:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 32 15.08 421 203 0.20 / 253.32 2 2
2 7 2007.92 36 14.78 2901 1544 1.75 / 254.87 2 2
3 13 1511.40 21 14.80 2319 721 2.47 / 255.59 2 2
4 13 850.92 21 14.91 1501 470 2.94 / 256.06 2 3
5 13 318.32 21 15.04 788 249 3.19 / 256.31 2 3
6 13 78.72 21 15.11 415 132 3.32 / 256.44 2 2
7 13 20.36 21 15.12 330 105 3.42 / 256.54 2 2
8 8 0.08 165 15.09 284 707 4.13 / 257.25 2 4
Average= 3.96
(KJ/cycle)

Cycle 63 GMT 26/ 4/2020 1:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 32 15.09 432 209 0.21 / 249.22 2 2
2 7 2004.36 36 14.79 2881 1534 1.74 / 250.76 2 3
3 13 1498.84 21 14.81 2305 717 2.46 / 251.47 2 2
4 13 827.56 21 14.92 1466 459 2.92 / 251.93 2 3
5 13 303.84 21 15.05 755 239 3.16 / 252.17 2 2
6 13 80.84 21 15.12 419 133 3.29 / 252.31 2 2
7 13 21.84 21 15.13 329 105 3.39 / 252.41 2 2
8 8 0.04 165 15.10 285 710 4.11 / 253.12 2 4
Average= 3.95
(KJ/cycle)

Cycle 62 GMT 16/ 4/2020 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 32 15.08 432 208 0.21 / 245.20 2 2
2 7 2010.84 36 14.78 2910 1548 1.76 / 246.75 2 3
3 13 1493.52 21 14.81 2319 721 2.48 / 247.47 2 3
4 13 814.12 21 14.92 1453 455 2.93 / 247.92 2 3
5 13 293.92 21 15.07 741 235 3.17 / 248.16 2 3
6 13 75.32 21 15.13 413 131 3.30 / 248.29 2 2
7 8 0.20 165 15.12 291 726 4.03 / 249.01 2 4
Average= 3.95
(KJ/cycle)

Cycle 61 GMT 6/ 4/2020 6:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 32 15.08 429 207 0.21 / 241.06 2 2
2 7 2005.28 36 14.79 2884 1536 1.74 / 242.59 3 3
3 13 1504.68 21 14.82 2315 720 2.46 / 243.32 2 2
4 13 839.44 21 14.92 1491 467 2.93 / 243.78 2 4
5 13 314.36 21 15.06 770 244 3.17 / 244.03 2 3
6 13 76.48 21 15.13 413 131 3.30 / 244.16 2 2
7 13 20.60 21 15.14 336 107 3.41 / 244.26 2 2
8 8 0.08 165 15.11 291 726 4.14 / 244.99 2 4
Average= 3.95
(KJ/cycle)

Cycle 60 GMT 27/ 3/2020 8:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 32 15.10 428 207 0.21 / 236.77 2 2
2 7 2012.08 36 14.78 2909 1548 1.75 / 238.31 2 2
3 13 1679.40 21 14.78 2530 785 2.54 / 239.10 2 3
4 13 938.76 21 14.90 1589 497 3.04 / 239.60 2 4
5 13 392.88 21 15.03 895 282 3.32 / 239.88 2 3
6 13 68.20 21 15.14 408 130 3.45 / 240.01 2 2
7 13 18.76 21 15.14 336 107 3.56 / 240.11 2 2
8 8 0.08 165 15.11 296 738 4.29 / 240.85 2 5
Average= 3.95
(KJ/cycle)

Cycle 59 GMT 17/ 3/2020 11: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 32 15.11 423 205 0.20 / 232.74 2 2
2 7 2003.60 37 14.79 2885 1579 1.78 / 234.31 2 2
3 13 1487.40 21 14.83 2272 708 2.49 / 235.02 2 2
4 13 816.84 21 14.94 1451 455 2.95 / 235.48 2 4
5 13 291.32 21 15.08 733 232 3.18 / 235.71 2 2
6 13 76.24 21 15.14 402 128 3.31 / 235.84 2 2
7 8 0.12 165 15.13 289 721 4.03 / 236.56 2 3
Average= 3.94
(KJ/cycle)

Cycle 58 GMT 7/ 3/2020 13:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 32 15.11 432 209 0.21 / 228.70 2 2
2 7 2003.44 36 14.80 2888 1539 1.75 / 230.24 2 2
3 13 1507.92 21 14.83 2308 719 2.47 / 230.96 2 3
4 13 969.04 21 14.91 1648 516 2.98 / 231.48 2 3
5 13 267.00 21 15.09 704 223 3.21 / 231.70 2 2
6 13 77.32 21 15.15 403 128 3.33 / 231.83 2 2
7 8 0.24 165 15.14 281 702 4.04 / 232.53 2 5
Average= 3.94
(KJ/cycle)

Cycle 57 GMT 26/ 2/2020 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 15.10 425 205 0.21 / 224.59 2 2
2 7 2011.84 36 14.79 2919 1554 1.76 / 226.14 2 3
3 13 1512.08 21 14.82 2348 731 2.49 / 226.87 2 2
4 13 982.12 21 14.89 1687 528 3.02 / 227.40 2 3
5 13 285.88 21 15.08 747 237 3.25 / 227.64 2 2
6 13 74.52 21 15.15 404 129 3.38 / 227.77 2 2
7 8 0.12 165 15.13 292 729 4.11 / 228.50 2 4
Average= 3.94
(KJ/cycle)

Cycle 56 GMT 16/ 2/2020 17:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 32 15.11 435 210 0.21 / 220.38 2 2
2 7 2004.60 36 14.79 2903 1546 1.76 / 221.93 2 2
3 13 1520.76 21 14.82 2353 732 2.49 / 222.66 2 2
4 13 1009.56 21 14.89 1705 533 3.02 / 223.19 2 3
5 13 283.32 21 15.10 704 223 3.24 / 223.42 2 2
6 13 74.12 21 15.16 403 128 3.37 / 223.55 2 2
7 13 16.84 21 15.16 332 106 3.48 / 223.65 2 2
8 8 -0.04 165 15.13 293 731 4.21 / 224.38 2 5
Average= 3.94
(KJ/cycle)

Cycle 55 GMT 6/ 2/2020 20: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 32 15.12 427 207 0.21 / 216.28 2 2
2 7 2003.12 36 14.80 2889 1539 1.75 / 217.82 2 3
3 13 1512.08 21 14.82 2346 730 2.48 / 218.55 2 2
4 13 980.20 21 14.91 1679 526 3.00 / 219.08 2 2
5 13 284.84 21 15.09 743 235 3.24 / 219.31 2 3
6 13 73.28 21 15.16 404 129 3.37 / 219.44 2 2
7 8 0.12 165 15.14 293 732 4.10 / 220.17 2 5
Average= 3.93
(KJ/cycle)

Cycle 54 GMT 27/ 1/2020 22:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 32 15.12 425 206 0.21 / 212.24 2 2
2 7 2003.32 36 14.81 2890 1541 1.75 / 213.78 2 3
3 13 1498.16 21 14.83 2324 724 2.47 / 214.50 2 3
4 13 845.16 21 14.95 1489 467 2.94 / 214.97 2 3
5 13 314.92 21 15.09 786 249 3.19 / 215.22 2 3
6 13 78.04 21 15.16 418 133 3.32 / 215.35 2 2
7 8 0.20 165 15.15 289 722 4.04 / 216.08 2 4
Average= 3.93
(KJ/cycle)

Cycle 53 GMT 18/ 1/2020 0:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 32 15.12 431 209 0.21 / 208.19 2 2
2 7 2006.56 36 14.81 2893 1542 1.75 / 209.73 2 2
3 13 1524.00 21 14.83 2323 723 2.47 / 210.45 2 2
4 13 846.72 21 14.96 1502 472 2.95 / 210.92 2 3
5 13 308.00 21 15.09 773 245 3.19 / 211.17 2 3
6 13 71.80 21 15.17 406 129 3.32 / 211.30 2 2
7 8 0.00 165 15.15 294 735 4.06 / 212.03 2 4
Average= 3.93
(KJ/cycle)

Cycle 52 GMT 8/ 1/2020 2:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 32 15.13 425 206 0.21 / 204.09 2 2
2 7 2009.48 36 14.81 2891 1541 1.75 / 205.63 2 2
3 13 1528.36 21 14.83 2335 727 2.47 / 206.35 2 2
4 13 1005.32 21 14.91 1699 532 3.01 / 206.89 2 7
5 13 282.60 21 15.11 741 235 3.24 / 207.12 2 3
6 13 69.48 21 15.17 397 126 3.37 / 207.25 2 2
7 8 0.12 165 15.15 292 730 4.10 / 207.98 2 3
Average= 3.92
(KJ/cycle)

Cycle 51 GMT 29/12/2019 5:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 32 15.13 424 205 0.21 / 200.03 2 2
2 7 2003.52 36 14.81 2884 1538 1.74 / 201.57 3 3
3 13 1487.56 21 14.85 2310 720 2.46 / 202.29 2 2
4 13 954.32 21 14.93 1621 508 2.97 / 202.79 2 4
5 13 268.20 21 15.12 716 227 3.20 / 203.02 2 3
6 13 69.40 21 15.18 402 128 3.33 / 203.15 2 2
7 8 0.12 165 15.16 292 730 4.06 / 203.88 2 3
Average= 3.92
(KJ/cycle)

Cycle 50 GMT 19/12/2019 7:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 32 15.13 438 212 0.21 / 195.96 2 2
2 7 2003.88 36 14.81 2902 1547 1.76 / 197.51 2 2
3 13 1509.36 21 14.84 2328 725 2.48 / 198.23 2 2
4 13 847.56 21 14.96 1504 472 2.96 / 198.71 2 5
5 13 315.04 21 15.11 771 245 3.20 / 198.95 2 3
6 13 78.08 21 15.17 427 136 3.34 / 199.09 2 2
7 8 0.12 165 15.16 294 735 4.07 / 199.82 2 3
Average= 3.92
(KJ/cycle)

Cycle 49 GMT 9/12/2019 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 32 15.14 430 208 0.21 / 191.73 2 2
2 7 2004.64 36 14.81 2910 1551 1.76 / 193.28 2 2
3 13 1671.64 21 14.82 2534 789 2.55 / 194.07 2 2
4 13 815.88 21 14.98 1454 457 3.01 / 194.53 2 4
5 13 305.64 21 15.11 764 242 3.25 / 194.77 2 2
6 13 73.40 21 15.18 420 134 3.38 / 194.91 2 2
7 13 15.40 21 15.19 335 107 3.49 / 195.01 2 2
8 8 0.12 165 15.16 294 735 4.22 / 195.75 2 5
Average= 3.91
(KJ/cycle)

Cycle 48 GMT 29/11/2019 11:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 32 15.14 426 206 0.21 / 187.66 2 2
2 7 2004.36 36 14.82 2903 1549 1.76 / 189.21 2 2
3 13 1507.16 21 14.85 2345 731 2.49 / 189.94 2 3
4 13 823.48 21 14.98 1475 464 2.95 / 190.41 2 3
5 13 310.56 21 15.11 778 247 3.20 / 190.65 2 3
6 13 77.52 21 15.18 416 133 3.33 / 190.79 2 2
7 8 0.08 165 15.17 295 738 4.07 / 191.52 2 3
Average= 3.91
(KJ/cycle)

Cycle 47 GMT 19/11/2019 14:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 32 15.15 422 205 0.20 / 183.62 2 2
2 7 2010.28 36 14.81 2925 1559 1.76 / 185.18 2 2
3 13 1367.80 21 14.88 2166 677 2.44 / 185.86 2 3
4 13 869.52 21 14.96 1532 481 2.92 / 186.34 2 4
5 13 327.08 21 15.11 795 252 3.17 / 186.59 2 3
6 13 71.96 21 15.18 410 131 3.31 / 186.73 2 2
7 8 0.04 165 15.17 292 731 4.04 / 187.46 2 4
Average= 3.91
(KJ/cycle)

Cycle 46 GMT 9/11/2019 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 15.15 426 200 0.20 / 179.56 2 2
2 7 2004.28 36 14.82 2906 1550 1.75 / 181.11 2 2
3 13 1517.20 21 14.85 2354 734 2.48 / 181.84 2 2
4 13 830.36 21 14.98 1487 468 2.95 / 182.31 2 3
5 13 303.68 21 15.12 769 244 3.20 / 182.55 2 3
6 13 77.68 21 15.19 421 134 3.33 / 182.69 2 2
7 8 0.12 165 15.17 292 731 4.06 / 183.42 2 4
Average= 3.90
(KJ/cycle)

Cycle 45 GMT 30/10/2019 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 31 15.15 445 209 0.21 / 175.42 2 2
2 7 2005.00 36 14.83 2916 1557 1.77 / 176.98 2 3
3 13 1520.96 21 14.86 2357 736 2.50 / 177.71 2 2
4 13 989.48 21 14.94 1704 535 3.04 / 178.25 2 3
5 13 288.64 21 15.13 754 240 3.28 / 178.49 2 3
6 13 80.04 21 15.19 421 134 3.41 / 178.62 2 2
7 8 0.08 165 15.18 294 736 4.15 / 179.36 2 5
Average= 3.90
(KJ/cycle)

Cycle 44 GMT 20/10/2019 20:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 31 15.15 436 205 0.20 / 171.31 2 2
2 7 2002.92 36 14.83 2911 1554 1.76 / 172.86 2 2
3 13 1483.60 21 14.87 2305 720 2.48 / 173.58 2 3
4 13 965.20 21 14.95 1664 522 3.00 / 174.11 2 6
5 13 264.72 21 15.14 708 225 3.23 / 174.33 2 2
6 13 67.04 21 15.20 412 132 3.36 / 174.46 2 2
7 8 0.16 165 15.18 299 749 4.11 / 175.21 2 4
Average= 3.89
(KJ/cycle)

Cycle 43 GMT 10/10/2019 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 15.16 429 202 0.20 / 167.21 2 2
2 7 2003.92 36 14.83 2911 1554 1.76 / 168.76 2 2
3 13 1520.64 21 14.86 2365 738 2.49 / 169.50 2 2
4 13 847.16 21 14.99 1510 475 2.97 / 169.97 2 4
5 13 310.24 21 15.13 785 249 3.22 / 170.22 2 3
6 13 69.88 21 15.20 418 133 3.35 / 170.36 2 2
7 8 0.08 165 15.18 299 749 4.10 / 171.11 2 5
Average= 3.89
(KJ/cycle)

Cycle 42 GMT 1/10/2019 1:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 31 15.16 428 201 0.20 / 163.14 2 2
2 7 2011.12 36 14.82 2926 1561 1.76 / 164.70 2 2
3 13 1504.60 21 14.87 2337 730 2.49 / 165.43 2 2
4 13 813.16 21 15.00 1463 461 2.95 / 165.89 2 4
5 13 294.16 21 15.14 759 241 3.19 / 166.13 2 3
6 13 72.08 21 15.20 415 132 3.33 / 166.26 2 2
7 8 0.08 165 15.19 296 742 4.07 / 167.00 2 3
Average= 3.88
(KJ/cycle)

Cycle 41 GMT 21/ 9/2019 3:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 31 15.16 429 202 0.20 / 159.07 2 2
2 7 2011.20 36 14.83 2925 1562 1.76 / 160.63 2 2
3 13 1513.16 21 14.87 2346 733 2.50 / 161.37 2 2
4 13 830.96 21 15.00 1485 468 2.96 / 161.83 2 3
5 13 307.64 21 15.14 777 247 3.21 / 162.08 2 3
6 13 75.40 21 15.20 410 131 3.34 / 162.21 2 2
7 8 0.08 165 15.19 289 724 4.07 / 162.94 2 4
Average= 3.88
(KJ/cycle)

Cycle 40 GMT 11/ 9/2019 5:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 31 15.17 432 203 0.20 / 155.02 2 2
2 7 2003.60 36 14.83 2919 1558 1.76 / 156.58 2 3
3 13 1382.88 21 14.90 2184 683 2.44 / 157.26 2 3
4 13 862.40 21 14.99 1536 484 2.93 / 157.75 2 4
5 13 321.52 21 15.13 794 252 3.18 / 158.00 2 2
6 13 79.60 21 15.20 420 134 3.31 / 158.13 2 2
7 8 0.08 165 15.19 294 737 4.05 / 158.87 2 4
Average= 3.87
(KJ/cycle)

Cycle 39 GMT 1/ 9/2019 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 31 15.18 425 200 0.20 / 150.91 2 2
2 7 2008.08 36 14.84 2907 1553 1.75 / 152.46 2 2
3 13 1493.80 21 14.88 2325 727 2.48 / 153.19 2 2
4 13 965.84 21 14.97 1680 528 3.01 / 153.72 2 3
5 13 266.80 21 15.16 723 230 3.24 / 153.95 2 2
6 13 72.72 21 15.21 415 133 3.37 / 154.08 2 2
7 8 0.08 165 15.20 294 737 4.11 / 154.82 2 2
Average= 3.87
(KJ/cycle)

Cycle 38 GMT 22/ 8/2019 10:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 31 15.18 434 204 0.20 / 146.83 2 2
2 7 2005.12 36 14.84 2914 1557 1.76 / 148.38 2 2
3 13 1497.56 21 14.89 2314 724 2.48 / 149.11 2 2
4 13 970.64 21 14.98 1654 520 3.00 / 149.63 2 6
5 13 262.56 21 15.16 707 225 3.23 / 149.85 2 2
6 13 75.36 21 15.22 401 128 3.36 / 149.98 2 2
7 8 0.08 165 15.21 291 730 4.09 / 150.71 2 3
Average= 3.86
(KJ/cycle)

Cycle 37 GMT 12/ 8/2019 12:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 31 15.18 431 203 0.20 / 142.72 2 2
2 7 2006.04 37 14.84 2914 1600 1.80 / 144.32 2 2
3 13 1513.60 21 14.88 2342 732 2.53 / 145.05 2 3
4 13 832.36 21 15.02 1477 466 3.00 / 145.51 2 3
5 13 310.36 21 15.15 777 247 3.25 / 145.76 2 3
6 13 80.00 21 15.22 416 133 3.38 / 145.89 2 2
7 8 0.04 165 15.21 290 728 4.11 / 146.62 2 4
Average= 3.86
(KJ/cycle)

Cycle 36 GMT 2/ 8/2019 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 31 15.18 437 206 0.21 / 138.64 2 2
2 7 2002.92 36 14.84 2917 1558 1.76 / 140.20 2 3
3 13 1485.48 21 14.89 2307 721 2.49 / 140.92 2 2
4 13 951.72 21 14.98 1644 517 3.00 / 141.44 2 4
5 13 250.48 21 15.17 688 219 3.22 / 141.66 2 2
6 13 70.76 21 15.22 405 129 3.35 / 141.79 2 2
7 8 0.12 165 15.21 289 725 4.08 / 142.51 2 3
Average= 3.85
(KJ/cycle)

Cycle 35 GMT 23/ 7/2019 16:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 31 15.19 435 205 0.20 / 134.48 2 2
2 7 2011.84 36 14.85 2941 1572 1.78 / 136.05 2 2
3 13 1530.04 21 14.88 2378 743 2.52 / 136.79 2 3
4 13 985.32 21 14.98 1681 529 3.05 / 137.32 2 4
5 13 268.08 21 15.17 732 233 3.28 / 137.55 2 3
6 13 79.36 21 15.22 425 136 3.42 / 137.69 2 2
7 8 0.12 165 15.21 298 748 4.17 / 138.44 2 4
Average= 3.85
(KJ/cycle)

Cycle 34 GMT 13/ 7/2019 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 31 15.19 424 200 0.20 / 130.53 2 2
2 7 2004.00 36 14.85 2921 1562 1.76 / 132.10 2 3
3 13 1361.08 21 14.92 2166 679 2.44 / 132.77 2 3
4 13 721.20 21 15.06 1346 426 2.87 / 133.20 2 3
5 13 231.60 21 15.18 659 210 3.08 / 133.41 2 2
6 13 67.44 21 15.23 402 129 3.20 / 133.54 2 2
7 8 0.04 165 15.22 292 733 3.94 / 134.27 2 5
Average= 3.84
(KJ/cycle)

Cycle 33 GMT 3/ 7/2019 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 31 15.20 423 199 0.20 / 126.43 2 2
2 7 2004.28 36 14.85 2917 1559 1.76 / 127.99 2 2
3 13 1496.04 21 14.90 2320 726 2.48 / 128.72 2 2
4 13 970.20 21 14.99 1664 524 3.01 / 129.24 2 2
5 13 262.32 21 15.18 710 226 3.23 / 129.47 2 2
6 13 76.88 21 15.23 416 133 3.37 / 129.60 2 2
7 8 0.16 165 15.22 291 731 4.10 / 130.33 2 3
Average= 3.83
(KJ/cycle)

Cycle 32 GMT 23/ 6/2019 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 31 15.20 434 205 0.20 / 122.36 2 2
2 7 2012.16 36 14.85 2940 1572 1.78 / 123.93 2 2
3 13 1509.88 21 14.90 2355 737 2.51 / 124.66 2 3
4 13 808.72 21 15.03 1472 465 2.98 / 125.13 2 4
5 13 294.84 21 15.17 759 242 3.22 / 125.37 2 3
6 13 79.48 21 15.23 413 132 3.35 / 125.50 2 2
7 8 0.08 165 15.22 292 733 4.08 / 126.24 2 4
Average= 3.83
(KJ/cycle)

Cycle 31 GMT 14/ 6/2019 1:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 31 15.19 434 204 0.20 / 118.28 2 2
2 7 2004.20 36 14.86 2913 1558 1.76 / 119.83 2 2
3 13 1500.92 21 14.91 2341 733 2.50 / 120.57 2 2
4 13 820.16 21 15.03 1471 464 2.96 / 121.03 2 5
5 13 287.36 21 15.17 751 239 3.20 / 121.27 2 3
6 13 81.44 21 15.23 434 139 3.34 / 121.41 2 2
7 8 0.08 165 15.22 295 741 4.08 / 122.15 2 7
Average= 3.82
(KJ/cycle)

Cycle 30 GMT 4/ 6/2019 3:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 31 15.20 417 196 0.20 / 114.19 2 2
2 7 2006.72 36 14.86 2931 1568 1.76 / 115.76 2 2
3 13 1363.88 21 14.94 2171 681 2.45 / 116.44 2 3
4 13 863.04 21 15.02 1533 484 2.93 / 116.93 2 4
5 13 329.56 21 15.16 821 261 3.19 / 117.19 2 3
6 13 86.92 21 15.23 440 141 3.33 / 117.33 2 2
7 8 0.04 165 15.22 296 743 4.07 / 118.07 2 4
Average= 3.81
(KJ/cycle)

Cycle 29 GMT 25/ 5/2019 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 31 15.20 429 202 0.20 / 110.03 2 2
2 7 2010.20 34 14.87 2937 1485 1.69 / 111.52 2 2
3 13 1689.60 20 14.89 2567 764 2.45 / 112.28 2 2
4 13 987.48 20 15.01 1689 507 2.96 / 112.79 2 2
5 13 323.12 20 15.18 793 241 3.20 / 113.03 2 3
6 13 91.24 20 15.24 443 135 3.33 / 113.16 2 2
7 13 22.56 20 15.25 334 102 3.44 / 113.27 2 2
8 8 0.04 165 15.22 291 731 4.17 / 114.00 2 4
Average= 3.80
(KJ/cycle)

Cycle 28 GMT 15/ 5/2019 7:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 31 15.21 426 201 0.20 / 105.92 2 2
2 7 2004.00 34 14.88 2931 1483 1.68 / 107.40 2 3
3 13 1534.52 20 14.92 2391 713 2.40 / 108.11 2 2
4 13 892.20 20 15.03 1570 472 2.87 / 108.58 2 3
5 13 372.52 20 15.15 887 269 3.14 / 108.85 2 3
6 13 97.52 20 15.24 453 138 3.28 / 108.99 2 2
7 13 23.84 20 15.25 340 104 3.38 / 109.09 2 2
8 8 0.04 165 15.22 293 736 4.12 / 109.83 2 4
Average= 3.79
(KJ/cycle)

Cycle 27 GMT 5/ 5/2019 9:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 15.21 432 204 0.20 / 101.81 2 2
2 7 2005.00 34 14.88 2916 1475 1.68 / 103.29 2 2
3 13 1515.28 20 14.93 2352 702 2.38 / 103.99 2 2
4 13 997.12 20 15.01 1710 513 2.89 / 104.50 2 5
5 13 323.96 20 15.18 804 244 3.14 / 104.75 2 3
6 13 96.40 20 15.24 451 137 3.28 / 104.88 2 2
7 13 23.48 20 15.26 340 104 3.38 / 104.99 2 2
8 8 0.08 165 15.23 289 726 4.11 / 105.71 2 4
Average= 3.78
(KJ/cycle)

Cycle 26 GMT 25/ 4/2019 11:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 31 15.22 426 201 0.20 / 97.59 2 2
2 10 1004.88 2 15.20 1748 53 0.25 / 97.65 2 2
3 3 955.08 -1 15.53 0 0 0.05 / 97.65 2 2
4 7 2004.32 34 14.89 2919 1478 1.73 / 99.13 2 3
5 13 1501.16 20 14.93 2347 701 2.43 / 99.83 2 2
6 13 972.92 20 15.02 1678 504 2.94 / 100.33 2 2
7 13 437.88 20 15.14 971 294 3.23 / 100.62 2 3
8 13 85.40 20 15.25 438 134 3.36 / 100.76 2 2
9 13 46.68 20 15.25 374 114 3.48 / 100.87 2 2
10 8 0.04 165 15.23 293 736 4.21 / 101.61 2 4
Average= 3.76
(KJ/cycle)

Cycle 25 GMT 15/ 4/2019 14:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 31 15.23 415 196 0.20 / 93.49 2 2
2 7 2005.24 34 14.89 2930 1483 1.68 / 94.98 2 3
3 13 1673.08 20 14.90 2545 758 2.44 / 95.74 2 2
4 13 835.56 20 15.06 1498 451 2.89 / 96.19 2 4
5 13 336.04 20 15.18 821 249 3.14 / 96.44 2 2
6 13 98.88 20 15.25 449 137 3.28 / 96.57 2 2
7 13 22.76 20 15.27 333 102 3.38 / 96.67 2 2
8 8 0.00 165 15.24 286 719 4.10 / 97.39 2 5
Average= 3.75
(KJ/cycle)

Cycle 24 GMT 5/ 4/2019 16:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 31 15.23 425 201 0.20 / 89.61 2 2
2 7 2006.52 34 14.90 2919 1479 1.68 / 91.09 2 2
3 13 1510.52 16 14.96 2358 564 2.24 / 91.66 2 2
4 13 1032.88 16 15.03 1770 426 2.67 / 92.08 2 4
5 13 536.72 16 15.14 1096 265 2.93 / 92.35 2 3
6 13 210.80 16 15.23 624 152 3.09 / 92.50 2 2
7 13 69.00 16 15.27 397 97 3.18 / 92.60 2 2
8 8 0.16 165 15.26 278 700 3.88 / 93.30 2 4
Average= 3.73
(KJ/cycle)

Cycle 23 GMT 26/ 3/2019 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 31 15.23 427 202 0.20 / 85.79 2 2
2 7 2008.36 34 14.90 2919 1479 1.68 / 87.27 2 2
3 13 1397.32 16 14.98 2221 532 2.21 / 87.80 2 3
4 13 953.32 16 15.04 1663 400 2.61 / 88.20 2 3
5 13 495.32 16 15.14 1051 255 2.87 / 88.46 2 4
6 13 188.24 16 15.23 587 143 3.01 / 88.60 2 2
7 13 63.16 16 15.27 392 96 3.11 / 88.70 2 2
8 8 0.16 165 15.25 285 717 3.82 / 89.41 2 3
Average= 3.73
(KJ/cycle)

Cycle 22 GMT 16/ 3/2019 19:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 31 15.23 414 195 0.20 / 81.88 2 2
2 7 2003.64 34 14.90 2924 1481 1.68 / 83.36 2 2
3 13 1520.80 16 14.96 2370 567 2.24 / 83.93 2 2
4 13 1030.32 16 15.04 1760 424 2.67 / 84.35 2 3
5 13 537.08 16 15.14 1109 269 2.94 / 84.62 2 4
6 13 206.96 16 15.23 624 152 3.09 / 84.77 2 2
7 13 63.64 16 15.27 397 97 3.19 / 84.87 2 2
8 8 0.08 165 15.26 287 723 3.91 / 85.59 2 3
Average= 3.72
(KJ/cycle)

Cycle 21 GMT 6/ 3/2019 21:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 31 15.23 431 203 0.20 / 77.99 2 2
2 7 2008.52 34 14.90 2921 1480 1.68 / 79.47 2 2
3 13 1508.36 16 14.97 2352 563 2.25 / 80.03 2 3
4 13 1021.08 16 15.04 1744 420 2.67 / 80.45 2 2
5 13 537.24 16 15.15 1107 268 2.93 / 80.72 2 3
6 13 201.64 16 15.24 618 151 3.09 / 80.87 2 2
7 13 63.44 16 15.27 398 97 3.18 / 80.96 2 2
8 8 0.12 165 15.26 285 718 3.90 / 81.68 2 3
Average= 3.71
(KJ/cycle)

Cycle 20 GMT 24/ 2/2019 23:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 30 15.24 425 194 0.19 / 74.05 2 2
2 7 2009.80 35 14.90 2923 1524 1.72 / 75.57 2 3
3 13 1499.52 16 14.98 2340 561 2.28 / 76.13 2 2
4 13 996.04 16 15.05 1717 413 2.69 / 76.55 2 3
5 13 497.36 16 15.16 1063 258 2.95 / 76.81 2 3
6 13 181.12 16 15.25 579 141 3.09 / 76.95 2 2
7 13 94.72 16 15.27 439 107 3.20 / 77.05 2 2
8 8 0.12 165 15.26 289 728 3.93 / 77.78 2 3
Average= 3.70
(KJ/cycle)

Cycle 19 GMT 15/ 2/2019 1:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 30 15.24 425 194 0.19 / 70.11 2 2
2 7 2007.76 34 14.91 2928 1484 1.68 / 71.60 2 2
3 13 1530.04 16 14.98 2378 570 2.25 / 72.17 2 3
4 13 1047.80 16 15.04 1788 430 2.68 / 72.60 2 3
5 13 544.36 16 15.15 1119 271 2.95 / 72.87 2 3
6 13 212.44 16 15.24 634 155 3.10 / 73.02 2 2
7 13 67.76 16 15.28 405 99 3.20 / 73.12 2 2
8 8 0.12 165 15.26 291 733 3.94 / 73.86 2 3
Average= 3.69
(KJ/cycle)

Cycle 18 GMT 5/ 2/2019 3:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 30 15.24 432 198 0.20 / 66.17 2 2
2 7 2005.04 34 14.92 2912 1477 1.67 / 67.64 2 2
3 13 1517.28 16 14.98 2362 566 2.24 / 68.21 2 2
4 13 1183.40 16 15.01 1947 468 2.71 / 68.68 2 4
5 13 511.60 16 15.16 1079 262 2.97 / 68.94 2 3
6 13 183.48 16 15.25 604 147 3.12 / 69.09 2 2
7 13 55.80 16 15.28 393 96 3.21 / 69.18 2 2
8 8 0.04 165 15.27 292 736 3.95 / 69.92 2 3
Average= 3.68
(KJ/cycle)

Cycle 17 GMT 26/ 1/2019 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 30 15.25 432 198 0.20 / 62.30 2 2
2 7 2003.84 34 14.92 2924 1483 1.68 / 63.78 2 2
3 13 1511.96 15 14.99 2361 531 2.21 / 64.31 2 2
4 13 1043.76 15 15.05 1774 400 2.61 / 64.71 2 4
5 13 564.20 15 15.15 1152 262 2.87 / 64.98 2 3
6 13 243.72 15 15.23 702 160 3.03 / 65.14 2 2
7 13 72.24 15 15.28 417 96 3.13 / 65.23 2 2
8 8 0.04 165 15.27 293 738 3.87 / 65.97 2 4
Average= 3.66
(KJ/cycle)

Cycle 16 GMT 16/ 1/2019 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 15.25 435 199 0.20 / 58.41 2 2
2 7 2003.76 34 14.92 2932 1487 1.69 / 59.90 2 2
3 13 1512.76 15 14.98 2382 535 2.22 / 60.44 2 2
4 13 1019.80 15 15.06 1752 396 2.62 / 60.83 2 3
5 13 686.76 15 15.12 1308 297 2.91 / 61.13 2 4
6 13 207.08 15 15.25 626 143 3.06 / 61.27 2 2
7 13 66.80 15 15.29 405 93 3.15 / 61.37 2 2
8 8 0.20 165 15.28 292 736 3.89 / 62.10 2 3
Average= 3.65
(KJ/cycle)

Cycle 15 GMT 6/ 1/2019 9:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 30 15.25 430 197 0.20 / 54.56 2 2
2 7 2004.28 34 14.93 2916 1480 1.68 / 56.04 2 2
3 13 1495.72 15 15.00 2342 527 2.20 / 56.57 2 2
4 13 1037.40 15 15.06 1775 401 2.60 / 56.97 2 2
5 13 553.80 15 15.16 1134 258 2.86 / 57.23 2 3
6 13 226.04 15 15.25 661 151 3.01 / 57.38 2 2
7 13 64.68 15 15.29 405 93 3.11 / 57.47 2 2
8 8 0.20 165 15.28 295 744 3.85 / 58.22 2 4
Average= 3.64
(KJ/cycle)

Cycle 14 GMT 27/12/2018 11:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 30 15.25 430 197 0.20 / 50.56 2 2
2 7 2009.64 34 14.93 2927 1486 1.68 / 52.04 2 2
3 13 1521.68 17 14.99 2382 607 2.29 / 52.65 2 2
4 13 1024.52 17 15.05 1752 448 2.74 / 53.10 2 4
5 13 496.40 17 15.17 1060 273 3.01 / 53.37 2 3
6 13 161.12 17 15.27 563 146 3.16 / 53.52 2 2
7 13 42.96 17 15.29 375 97 3.25 / 53.61 2 2
8 8 0.04 165 15.27 298 751 4.01 / 54.36 2 4
Average= 3.62
(KJ/cycle)

Cycle 13 GMT 17/12/2018 13:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 30 15.25 439 201 0.20 / 46.47 2 2
2 7 2008.76 34 14.94 2929 1488 1.69 / 47.96 2 3
3 13 1677.20 17 14.96 2567 653 2.34 / 48.61 2 2
4 13 1147.44 17 15.03 1903 486 2.83 / 49.10 2 3
5 13 470.20 17 15.18 1022 264 3.09 / 49.36 2 3
6 13 160.72 17 15.27 557 145 3.24 / 49.51 2 2
7 13 40.36 17 15.30 373 97 3.33 / 49.61 2 2
8 8 0.12 165 15.27 299 753 4.09 / 50.36 2 3
Average= 3.60
(KJ/cycle)

Cycle 12 GMT 7/12/2018 15:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 15.25 427 195 0.20 / 42.55 2 2
2 7 2007.00 34 14.94 2929 1488 1.68 / 44.04 2 2
3 13 1518.48 17 14.99 2377 606 2.29 / 44.65 2 3
4 13 885.72 17 15.10 1572 404 2.69 / 45.05 2 3
5 13 411.76 17 15.20 943 244 2.94 / 45.29 2 3
6 13 136.32 17 15.28 519 135 3.07 / 45.43 2 2
7 13 39.20 17 15.30 369 96 3.17 / 45.52 2 2
8 8 0.04 165 15.28 297 749 3.92 / 46.27 2 7
Average= 3.56
(KJ/cycle)

Cycle 11 GMT 27/11/2018 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 15.25 430 197 0.20 / 38.67 2 2
2 7 2011.76 34 14.94 2924 1485 1.68 / 40.16 2 2
3 13 1392.52 17 15.02 2213 565 2.25 / 40.72 2 3
4 13 917.64 17 15.09 1612 414 2.66 / 41.13 2 5
5 13 422.56 17 15.20 952 246 2.91 / 41.38 2 3
6 13 131.12 17 15.28 515 134 3.04 / 41.51 2 2
7 13 37.00 17 15.30 364 95 3.14 / 41.61 2 2
8 8 0.04 165 15.28 297 749 3.88 / 42.36 2 4
Average= 3.53
(KJ/cycle)

Cycle 10 GMT 17/11/2018 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 15.25 440 201 0.20 / 34.63 2 2
2 7 2013.04 34 14.95 2929 1489 1.69 / 36.12 2 3
3 13 1509.84 17 15.00 2358 601 2.29 / 36.72 2 3
4 13 1172.16 17 15.03 1934 494 2.79 / 37.21 2 4
5 13 462.32 17 15.19 1011 261 3.05 / 37.47 2 3
6 13 147.40 17 15.28 544 141 3.19 / 37.61 2 2
7 13 36.92 17 15.31 368 96 3.28 / 37.71 2 2
8 8 0.04 165 15.28 303 764 4.05 / 38.47 2 5
Average= 3.50
(KJ/cycle)

Cycle 9 GMT 7/11/2018 20:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 30 15.26 444 203 0.20 / 30.64 2 2
2 7 2003.48 34 14.95 2933 1491 1.69 / 32.13 2 2
3 13 1487.68 17 15.01 2325 593 2.29 / 32.72 2 3
4 13 973.36 17 15.08 1696 435 2.72 / 33.16 2 4
5 13 468.36 17 15.19 1031 266 2.99 / 33.42 2 3
6 13 148.36 17 15.28 545 142 3.13 / 33.56 2 2
7 13 33.40 17 15.31 369 96 3.23 / 33.66 2 2
8 8 0.16 165 15.28 304 766 3.99 / 34.43 2 5
Average= 3.44
(KJ/cycle)

Cycle 8 GMT 28/10/2018 22:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 30 15.26 451 206 0.21 / 26.72 2 2
2 7 2004.16 34 14.95 2935 1492 1.70 / 28.21 2 2
3 13 1500.52 17 15.01 2347 599 2.30 / 28.81 2 3
4 13 866.60 17 15.11 1554 399 2.70 / 29.21 2 4
5 13 545.40 17 15.16 1139 294 2.99 / 29.50 2 3
6 13 113.92 17 15.29 500 130 3.12 / 29.63 2 2
7 8 0.12 165 15.29 317 800 3.92 / 30.43 2 4
Average= 3.38
(KJ/cycle)

Cycle 7 GMT 19/10/2018 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 15.26 447 198 0.20 / 22.71 2 2
2 3 1018.56 1 15.30 1799 28 0.23 / 22.74 2 2
3 7 2002.52 35 14.95 2932 1534 1.76 / 24.27 2 3
4 13 1490.76 17 15.02 2345 599 2.36 / 24.87 2 2
5 13 985.28 17 15.08 1703 437 2.79 / 25.31 2 4
6 13 483.92 17 15.19 1040 269 3.06 / 25.58 2 3
7 13 148.00 17 15.28 552 143 3.21 / 25.72 2 2
8 8 0.24 165 15.29 314 792 4.00 / 26.51 2 3
Average= 3.31
(KJ/cycle)

Cycle 6 GMT 9/10/2018 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 28 15.26 430 184 0.18 / 18.79 2 2
2 3 1047.64 1 15.26 1840 28 0.21 / 18.81 2 3
3 7 2002.76 34 14.97 2911 1482 1.69 / 20.30 3 2
4 13 1491.12 18 15.02 2345 634 2.33 / 20.93 2 3
5 13 962.16 18 15.09 1681 457 2.78 / 21.39 2 5
6 13 322.24 18 15.24 819 225 3.01 / 21.61 2 3
7 13 106.08 18 15.30 476 131 3.14 / 21.74 2 2
8 8 0.16 165 15.29 306 772 3.91 / 22.51 2 3
Average= 3.22
(KJ/cycle)

Cycle 5 GMT 29/ 9/2018 4:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 15.28 422 181 0.18 / 14.88 2 2
2 3 1021.24 1 15.31 1790 27 0.21 / 14.91 2 2
3 7 2004.32 34 14.97 2900 1476 1.68 / 16.38 2 2
4 13 1475.36 18 15.03 2300 622 2.31 / 17.01 2 2
5 13 965.56 18 15.10 1663 452 2.76 / 17.46 2 3
6 13 448.40 18 15.20 987 270 3.03 / 17.73 2 3
7 13 85.64 18 15.31 444 122 3.15 / 17.85 2 2
8 8 0.12 165 15.29 298 752 3.90 / 18.60 2 3
Average= 3.10
(KJ/cycle)

Cycle 4 GMT 19/ 9/2018 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 28 15.28 419 179 0.18 / 11.50 2 2
2 7 1508.48 34 15.11 2297 1180 1.36 / 12.68 2 2
3 13 1361.48 18 15.10 2137 581 1.94 / 13.26 2 3
4 13 835.00 18 15.16 1476 403 2.34 / 13.67 2 3
5 13 303.84 18 15.27 756 208 2.55 / 13.87 2 2
6 13 82.44 18 15.33 416 115 2.67 / 13.99 2 2
7 8 -0.04 165 15.31 282 712 3.38 / 14.70 2 7
Average= 2.94
(KJ/cycle)

Cycle 3 GMT 18/ 9/2018 6:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 28 15.29 411 176 0.18 / 7.77 2 2
2 7 1522.56 74 15.00 2292 2544 2.72 / 10.32 3 2
3 13 263.44 18 15.28 684 188 2.91 / 10.51 2 2
4 13 76.00 18 15.33 396 109 3.02 / 10.61 2 2
5 8 0.16 165 15.31 280 707 3.72 / 11.32 2 4
Average= 2.83
(KJ/cycle)

Cycle 2 GMT 17/ 9/2018 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 28 15.34 410 176 0.18 / 4.11 2 2
2 7 1509.12 74 15.02 2265 2518 2.69 / 6.62 2 2
3 13 257.52 18 15.29 670 184 2.88 / 6.81 2 2
4 13 78.20 18 15.33 389 107 2.99 / 6.91 2 2
5 8 0.12 165 15.32 270 683 3.67 / 7.60 2 3
Average= 2.53
(KJ/cycle)

Cycle 1 GMT 16/ 9/2018 7: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 28 15.52 349 152 0.15 / 1.39 2 3
2 7 1000.48 74 15.18 1633 1834 1.99 / 3.23 3 3
3 8 -0.04 165 15.38 276 700 2.69 / 3.93 2 3
Average= 1.96
(KJ/cycle)

Cycle 0 GMT 15/ 9/2018 20:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 64.32 22 15.66 309 106 0.11 / 0.11 2 3
2 7 80.64 74 15.63 326 377 0.48 / 0.48 3 2
3 8 0.32 240 15.59 203 760 1.24 / 1.24 2 3
Average= 1.24
(KJ/cycle)